Subido por dustceniza21

Guía de bolsillo - ASHRAE

Anuncio
Cover_rev.fm Page 1 Monday, February 29, 2016 4:52 PM
(Edición I-P y SI)
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is per
para
Aire Acondicionado, Calefacción,
Ventilación, Refrigeración
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
GUIA DE
BOLSILLO DE
ASHRAE
Span_Front1_title&copyright.fm Page i Thursday, March 3, 2016 12:08 PM
(Edición I-P y SI)
ASHRAE · 1791 Tullie Circle, NE Atlanta, GA 30329 · www.ashrae.org
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
para
Aire Acondicionado, Calefacción,
Ventilación, Refrigeración
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
GUIA DE
BOLSILLO DE
ASHRAE
Span_Front1_title&copyright.fm Page ii Thursday, March 3, 2016 12:08 PM
ISBN 978-1-939200-16-7 (Libro de Bolsillo)
978-1-939200-17-4 (PDF)
Código de Producto: 90074 03/16
This publication translated by permission © 2013 ASHRAE. Translation by Asociación Técnica Ecuatoriana
de Aire Acondicionado y Refrigeración (ATEAAR). ASHRAE assumes no responsibility for the accuracy of
the translation. To purchase the English-language edition, contact ASHRAE, 1791 Tullie Circle, NE, Atlanta,
GA 30329-2305 USA, www.ashare.org.
Este publicación ha sido traducido bajo los derechos de autor © 2013 y con la debida autorización de
ASHRAE. La traducción ha sido realizada por la Asociación Técnica Ecuatoriana de Aire Acondicionado y
Refrigeración (ATEAAR). ASHRAE no asume responsabilidad por la exactitud de la traducción. Para comprar
la edición en lenguaje Inglés se puede contactar a ASHRAE, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305
Estados Unidos, www.ashrae.org.
ASHRAE is a registered trademark in the U.S. Patent and Trademark Office, owned by the
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
ASHRAE es una marca registrada en los Estados Unidos. Patente y marca propiedad de la Sociedad
Americana de Ingenieros de Calefacción, Refrigeración y Aire Acondicionado, Inc.
Ninguna parte de este manual puede ser reproducido sin permiso por escrito de ASHRAE, excepto por un
revisor quien puede citar pasajes breves o reproducir ilustraciones en una revisión con el crédito apropiado, ni
ninguna parte de este libro se reproducirá, almacenará en un sistema de recuperación, o transmitido en cualquier
forma o por cualquier medio - electrónico, fotocopiado, grabación u otro - sin permiso por escrito de ASHRAE.
Las solicitudes para permiso deben ser presentadas a www.ashrae.org/permissions.
ASHRAE ha elaborado esta publicación con cuidado, pero ASHRAE no ha investigado y ASHRAE expresamente declina cualquier obligación de investigar, cualquier producto, servicio, proceso, procedimiento, diseño o
similar que pueda ser descrito aquí. La aparición de cualquier dato técnico o material editorial en esta publicación
no constituye justificación o garantía de ASHRAE de cualquier producto, servicio, proceso, procedimiento,
diseño o similar. ASHRAE no garantiza que la información en esta publicación está libre de errores y ASHRAE
no necesariamente está de acuerdo con cualquier declaración u opinión en esta publicación. El riesgo entero del
uso de cualquier información en esta publicación es asumida por el usuario.
Library of Congress Cataloging-in-Publication Data
Personal de ASHRAE
Special Publications Mark S. Owen, Editor/Group Manager of Handbook and Special Publications
Cindy Sheffield Michaels, Managing Editor
James Madison Walker, Associate Editor
Sarah Boyle, Assistant Editor
Lauren Ramsdell, Assistant Editor
Michshell Phillips, Editorial Coordinator
Publishing Services David Soltis, Group Manager of Publishing Services and Electronic Communications
Jayne Jackson, Publication Traffic Administrator
Publisher
W. Stephen Comstock
Actualizaciones/erratas para esta publicación serán anunciados
en el sitio red de ASHRAE en www.ashrae.org/publicationupdates.
Las erratas observadas en la lista fechada 08/6/2014 han sido corregidas.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Names: ASHRAE (Firm), editor.
Title: Guía de bolsillo de ASHRAE para aire acondicionado, calefacción,
ventilación, refrigeración.
Other titles: Pocket guide for air conditioning, heating, ventilation,
refrigeration. Spanish
Description: Edición I-P y SI. | Atlanta, GA : ASHRAE, 2016. | Translation
of: ASHRAE pocket guide for air conditioning, heating, ventilation,
refrigeration; first published under title: Pocket guide for air
conditioning, heating, ventilation, refrigeration. | Includes index.
Identifiers: LCCN 2016001373| ISBN 9781939200167 (pbk.) | ISBN 9781939200174
(pdf)
Subjects: LCSH: Heating--Equipment and supplies--Handbooks, manuals, etc. |
Ventilation--Handbooks, manuals, etc. | Air conditioning--Handbooks,
manuals, etc. | Refrigeration and refrigerating machinery--Handbooks,
manuals, etc.
Classification: LCC TH7011 .P6318 2016 | DDC 697.9/2--dc23 LC record available at http://lccn.loc.gov/
2016001373
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
© 2013 ASHRAE
Todos los derechos reservados.
Impreso en los Estados Unidos de América
Sp an_F ro nt2_TOC (2).fm Pag e iii Thursday , M arc h 3, 2016 12:10 PM
Prefacio.........................................................................................................................viii
Tratamiento de Aire y Psicometrías
Gráfico de Fricción de Aire................................................................................... 1–2
Velocidades vs. Presiones de Velocidad ................................................................. 3
Conductos No Circulares ......................................................................................... 4
Accesorios y Conductos Flexibles ........................................................................... 4
Fugas de Conductos ............................................................................................ 4–6
Pérdidas de Accesorios ........................................................................................... 7
Equivalentes Circulares de Ductos Rectangulares .............................................8-11
Equivalentes de Ductos Ovalados Planos ....................................................... 12–13
Velocidades para Componentes de HVAC ............................................................ 14
Leyes de Ventilación ........................................................................................ 15–16
Tipos de Ventiladores ...................................................................................... 17–18
Efecto del Sistema de Ventilación.......................................................................... 19
Gráfico Psicométrico ........................................................................................ 20–21
Procesos de Aire Acondicionado ..................................................................... 22–25
Entalpia de Aire................................................................................................ 26–27
Datos Atmosféricos Estándar................................................................................. 28
Datos de Aire Húmedo........................................................................................... 28
Difusión de Aire Espacio .................................................................................. 29–30
Principios de Comportamiento de Chorro ........................................................ 31–33
Patrones de Corriente de Aire de Difusores Diferentes ................................... 34–35
Sistemas de Aire Mezclado.................................................................................... 36
Sistemas Totalmente Estratificados................................................................. 41–43
Sistemas Parcialmente Mezclados .................................................................. 43–44
Diseño de Aire de Retorno..................................................................................... 45
2
Contaminantes de Aire y Control
Normas de Calidad de Aire .................................................................................... 46
Depuradores de Aire Electrónico ........................................................................... 47
Bioaerosoles .......................................................................................................... 47
Instalaciones de Filtros .......................................................................................... 47
Parámetros MERV ................................................................................................. 48
Pautas de Aplicación de Filtros............................................................................. 49
Fuentes de Contaminantes Interiores ............................................................. 50–52
Contaminantes Gaseosos por Materiales de Construcción ............................. 53–54
Sistemas de Lámparas Ultravioletas................................................................ 55–56
Velocidades de Captura de Campana ................................................................... 57
Diseño de Conducto de Escape y Construcción.............................................. 57–60
Velocidades de Transporte de Contaminantes ...................................................... 59
Pérdida de Entrada de Campana........................................................................... 60
Ventilación de Cocina ...................................................................................... 61–63
Campanas de Laboratorio...................................................................................... 63
Espacios Limpios ................................................................................................... 64
Límites de Concentración de Partículas Suspendidas en el Aire .......................... 65
3
Agua
Términos de Bomba y Fórmulas ............................................................................ 66
Leyes de Afinidad para Bombas ........................................................................... 66
Aplicación de Leyes de Afinidad ............................................................................ 67
Características de Succión Positiva Neta ........................................................ 68–69
Curvas de Bombas Típicas .................................................................................... 70
Propiedades del Agua............................................................................................ 72
Flujo de Masa y Calor Específico del Agua ........................................................... 73
Puntos de Congelación de Glicol ........................................................................... 73
Capacidad de Tanque Cilíndrico Vertical............................................................... 74
iii
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
1
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
CONTENIDO
Sp an_F ro nt2_TOC (2).fm Pag e iv Thursday , M arc h 3, 2016 12:10 PM
Vapor
Tabla de Vapor ................................................................................................ 88–90
Gráfico de Vapor.............................................................................................. 91–92
Velocidad de Flujo de Tubos de Vapor............................................................ 93–94
Capacidades de Tubos de Vapor .................................................................... 95–96
Capacidades de Tubos de Vapor—Red de Retorno y Elevación .................... 97–99
5
Tubería
Datos de Tubos de Acero .............................................................................. 100–05
Datos de Tubos de Cobre.............................................................................. 106–11
Propiedades de Materiales de Tubos Plásticos............................................. 112–15
Tubos, Accesorios y Aplicaciones de Válvulas............................................. 116–17
Expansión Térmica de Tubos de Metal ......................................................... 118–19
Espaciamiento de Percha y Tamaños de Varillas ........................................ 120–21
6
Servicio de Calentamiento de Agua
Elementos del Sistema de Servicio de Calentamiento.de Agua.......................... 122
Legionella Pneumophila (Enfermedad de Legionarios) ....................................... 122
Diversidad de Carga ...................................................................................... 123–25
Demanda de Agua Caliente para Edificios .......................................................... 126
Demanda de Agua Caliente para Accesorios ................................................ 127–30
Velocidad de Circulación de Agua Caliente................................................... 131–32
7
Uso de Energía Solar
Irradiación Solar............................................................................................. 133–36
Datos del Colector Solar ............................................................................... 137–38
Sistemas de Calefacción Solar ...................................................................... 139–40
8
Ciclos de Refrigeración
Coeficiente de Rendimiento (COP)...................................................................... 141
Ciclo de Compresión de Vapor ...................................................................... 142–43
Refrigeración por Absorción ................................................................................ 144
Características del Enfriador de Bromuro de Litio ......................................... 145–46
9
Refrigerantes
Datos del Refrigerante ......................................................................................... 147
Gráfico de Presión-Entalpia—R-22............................................................... 148–49
Tablas de Propiedad—R-22 .......................................................................... 150–53
Gráfico Presión-Entalpia—R-123................................................................... 154–55
Tabla de Propiedad—R-123 .......................................................................... 156–57
Gráfico de Presión-Entalpia—R-134a............................................................ 158–59
Tablas de Propiedad—R-134a ...................................................................... 160–63
Gráfico de Presión-Entalpia—T-717 (Amoniaco)........................................... 164–65
Tablas de Propiedad—R-717 (Amoniaco) ..................................................... 166–67
Gráfico de Presión-Entalpia—R-404A .......................................................... 168–69
Tabla de Propiedad—R-404A........................................................................ 170–71
Gráfico de Presión-Entalpia—R-407C ........................................................... 172–73
Tabla de Propiedad—R-407C........................................................................ 174–75
Gráfico de Presión-Entalpia—R-410A ........................................................... 176–77
Tabla de Propiedad—R-410A........................................................................ 178–79
Gráfico de Presión-Entalpia—R-507A ........................................................... 180–81
Tabla de Propiedad—R-507A........................................................................ 182–83
Gráfico de Presión-Entalpia—R-1234yf......................................................... 184–85
iv
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
4
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Capacidad de Tanque Cilíndrico Horizontal .......................................................... 74
Volumen de Agua en Tubos y Tuberías ................................................................ 75
Gráfico de Fricción de Tubos de Agua, Cobre................................................. 76–77
Gráfico de Fricción de Tubos de Agua, Plástico.............................................. 78–79
Gráfico de Fricción de Tubos de Agua, Acero ................................................. 80–81
Pérdida por Fricción en Accesorios de Tuberías ............................................. 82–87
Sp an_F ro nt2_TOC (2).fm Pag e v Thursday , M arc h 3, 2016 12:10 PM
10 Seguridad de Refrigerantes
Clasificación del Grupo de Seguridad.................................................................. 234
Datos y Clasificación de Seguridad para Refrigerantes y Mezclas................ 235–36
Norma 15-2010 de ASHRAE. ........................................................................ 237–43
11 Carga de Refrigeración
Carga de Transmisión.......................................................................................... 244
Carga de Producto ............................................................................................... 245
Carga Interna ....................................................................................................... 246
Carga de Aire de Infiltración................................................................................. 246
Carga Relacionada con Equipos.................................................................... 247–48
Factor de Seguridad............................................................................................. 248
Enfriadores de Aire de Circulación Forzada ................................................. 248–49
13 Ventilación
Norma 62.2-2010 de ASHRAE ............................................................................ 310
Norma 62.1-2010.de ASHRAE ...................................................................... 311–13
Procedimientos de la Norma 62.1-2010 de ASHRAE.................................... 313–22
v
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
12 Datos de Carga de Aire Acondicionado
Cargas de Calefacción y Enfriamiento........................................................... 250–51
Valores de Verificación de Cargas de Refrigeración ..................................... 252–53
Proceso de Cálculo de Carga de Refrigeración.................................................. 254
Flujo de Calor a través de los Materiales de Construcción .................................. 255
Resistencia Térmica de Espacios de Aire Plano ........................................... 256–57
Conductancias de Superficie y Resistencias ................................................. 258–59
Emisividad............................................................................................................ 259
Resistencia Térmica de Áticos Ventilados ..................................................... 260–61
Propiedades Térmicas de Materiales............................................................. 262–71
Diferencias de Temperatura de Carga de Refrigeración (CLTD)
para Techos Planos ................................................................................272–74
Diferencia de Temperatura de Carga de Refrigeración (CLTD)
para Paredes Iluminadas por Luz Solar......................................................... 275–77
Carga de Refrigeración Solar para Vidrios Iluminados por Luz Solar............ 278–79
Coeficientes de Sombreado para.Vidrios....................................................... 280–81
Ganancia de Calor de Seres Humanos ......................................................... 282–83
Ganancia de Calor de Iluminación y LPDs .................................................... 284–91
Ganancia de Calor de Motores ...................................................................... 291–94
Ganancia de Calor de Equipos de Restaurantes........................................ 295–303
Ganancia de Calor de Equipos de Hospitales y Laboratorio ......................... 303–05
Ganancia de Calor de Equipos de Oficina ..................................................... 306–08
Efecto de Refrigeración de Accesorios Expuestos .............................................. 309
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla de Propiedad—R1234yf....................................................................... 186–87
Gráfico de Presión-Entalpia—R-1234ze(E) ................................................... 188–89
Tabla de Propiedad—R-1234ze(E)................................................................ 190–91
Procedimiento Refrigerante.Comparativo ...................................................... 192–95
Capacidades de Línea del Refrigerante—R-404A......................................... 196–99
Capacidades de Línea del Refrigerante—R-507A......................................... 200–03
Capacidades de Línea del Refrigerante—R-410A......................................... 204–07
Capacidades de Línea del Refrigerante—R-407C......................................... 208–11
Capacidades de Línea del Refrigerante—R-22 ............................................. 212–15
Capacidades de Línea del Refrigerante—R-134a ......................................... 216–19
Arrastre de Petróleo en Elevadores de Succión—R-22 y R-134a ................. 220–23
Arrastre de Petróleo en Elevadores de Gas Caliente—R-22 y R-134a ......... 224–27
Capacidades de Línea de Refrigeración—Amoniaco (R717) ........................ 228–29
Capacidades de Línea al Amoníaco .............................................................. 230–31
Lubricantes en Sistemas Refrigerantes ............................................................... 232
Refrigerantes Secundarios............................................................................. 232–33
Energía de Bombeo Relativo ............................................................................... 233
Sp an_F ro nt2_TOC (2).fm Pag e vi Thursday , M arc h 3, 2016 12:10 PM
14 Diseño de Conservación de Energía
Sostenibilidad................................................................................................ 331–32
Normas de Eficiencia Energética........................................................................ 332
Zonas Climáticas para Ubicaciones en los Estados Unidos................................ 333
15 Eléctrico
Características de Motores AC ............................................................................ 334
Amperios de Motores a Plena Carga............................................................. 335–36
Fórmulas Eléctricas Útiles ................................................................................... 337
Controladores de Motores ................................................................................... 337
Accionamiento de Velocidad Variable (VSDs)............................................... 337–38
Sistemas Fotovoltaicos ........................................................................................ 339
16 Absorbentes y Desecantes
Ciclo Desecante................................................................................................... 340
Equipo Desecante.......................................................................................... 341–42
Deshumidificación del Desecante........................................................................ 343
Modelo Deshumidificador del Desecante Sólido Rotativo ............................. 344–49
17 Calor Combinado y Sistemas Eléctricos
Ciclos de Calor Combinado y Energía (CHP)................................................ 350–51
Tablas de Tamaño del Motor ............................................................................... 352
Mantenimiento de Motor Recomendado.............................................................. 353
Rendimiento de Enfriador de Motor a Gas .......................................................... 354
Balance Calorífico para Motor ............................................................................. 355
Diagrama de Límite de Energía ........................................................................... 356
Temperaturas de Aplicación de Calor.................................................................. 356
Flujos de Masas y Temperaturas para Varios Motores ....................................... 356
Tasas de Vapor para Turbinas a Vapor......................................................... 357–58
Turbinas de Combustión................................................................................ 359–60
Células de Combustible ................................................................................. 360–61
19 Posesión y Operación
Costos de Mantenimiento .............................................................................. 370–71
Datos de Costos de Posesión y Operación ......................................................... 372
Análisis Económicos ...................................................................................... 373–74
20 Acústica
Presión Acústica y Niveles de Presión Acústica.................................................. 375
Combinación de Niveles Acústicos ...................................................................... 376
Potencia Acústica y Nivel de Potencia Acústica ................................................. 376
Ponderación A y C .............................................................................................. 376
Bandas de Octava y 1/3 de Octava de Banda.................................................... 377
Pautas de Diseño para Sistemas de HVAC......................................................... 378
Métodos de Calificación de Acústica ............................................................. 379–80
Trayectos de Acústica en Sistemas HVAC.......................................................... 380
Silenciadores ....................................................................................................... 381
Configuraciones de Salida ................................................................................... 382
Niveles de Ruido de Equipo Mecánico ................................................................ 382
Aisladores de Acústica de Equipo Mecánico ................................................. 383–84
vi
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
18 Combustibles y Combustión
Tabla de Calibre de Tubos de Gas ................................................................ 362–63
Valores de Viscosidad y Calor de Combustible ............................................. 364–65
Combustibles Líquidos para Motores .................................................................. 366
Tablas de Calibre de Tubos de Aceite Combustible...................................... 367–69
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Normativo de Apéndice A de la Norma 62.1-2010 de ASHRAE.................... 323–26
Parámetros de Diseño para Instalaciones de Centros de Salud ................... 327–29
Operación y Mantenimiento ................................................................................. 330
Sp an_F ro nt2_TOC (2).fm Pag e vii Thursday , M arc h 3, 2016 12:10 PM
22 Enfriamiento por Evaporación
Evaporación Directa de Enfriadores de Aire ........................................................ 402
Evaporación Indirecta de Enfriadores de Aire................................................ 403–05
Enfriadores Evaporativos de Múltiples Etapas............................................... 406–07
Gráfico de Temperatura Efectiva ......................................................................... 407
23 Controles Automáticos
Componentes del Sistema de HVAC ............................................................. 408–14
Sistemas HVAC ............................................................................................. 415–16
24 Comodidad del Ocupante
Norma 55-2010 de ASHRAE ......................................................................... 417–18
Método de Zona de Confort Gráfico..................................................................... 417
Temperatura Operativa y Efectiva ....................................................................... 418
Voto Medio Predicho............................................................................................ 418
Velocidad de Aire para Compensación................................................................ 418
Valores de Aislamiento de Ropa.......................................................................... 419
Inconformidad Local....................................................................................... 419–20
Comodidad Térmica en Edificios Ventilados Naturalmente ................................. 420
25 Sistemas Geotérmicos
Bombas de Calor de Fuente a Tierra............................................................. 421–23
Propiedades Térmicas de Suelos y Rocas .................................................... 423–24
Tuberías de Tierra.......................................................................................... 425–27
Tuberías de Agua Superficiales ........................................................................... 428
Indice....................................................................................................................456–457
vii
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
26 General
Criterios de Diseños del Sistema ................................................................... 429–32
Unidades SI y Fórmulas de Aire Acondicionado............................................ 433–34
Fórmulas de Medición para Calefacción/Refrigeración ....................................... 435
Rendimiento de Torre de Enfriamiento .......................................................... 436–37
Acumulación Térmica..................................................................................... 438–39
Distribución de Aire Frio...................................................................................... 440
Deshumidificadores Mecánicos ........................................................................... 440
Tubos de Calor.............................................................................................. 442–43
Recuperación de Energía Aire a Aire............................................................. 443–46
Panel de Calefacción y Enfriamiento ............................................................. 447–49
Flujo de Refrigerante Variable ....................................................................... 450–53
Unidades y Conversiones .............................................................................. 454–55
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
21 Vibración
Un Solo Grado de Sistemas de Libertad.............................................................. 385
Dos Grados de Sistema de Libertad .................................................................... 385
Selección de Aislamiento ............................................................................. 386–401
Span_Front3_Preface.fm Page viii Thursday, March 3, 2016 12:10 PM
La Guía de Bolsillo de ASHRAE fue desarrollado para servir como una referencia rápida,
fuera de línea para ingenieros sin acceso rápido a los volúmenes grandes del Manual de
ASHRAE. La mayoría de la información está tomada de los cuatro volúmenes de las series de los
Manuales de ASHRAE, así como de varias de las Normas de ASHRAE y abreviada o reducida
para ajustarse al tamaño pequeño de la página.
Esta octava edición, revisada y extendida para el 2013, incluye propiedades para refrigerantes
nuevos, nuevos datos sobre seguridad refrigerante, requisitos de ventilación para ocupaciones residenciales y no residenciales, confort térmico para ocupantes, datos extensivos sobre sonido y
control de vibración, almacenaje térmico, panel radiante de calefacción y refrigeración, recuperación de energía aire-a-aire, datos de difusión de aire en el espacio, datos e carga de calor del
equipo, turbinas de combustión, células de combustible, sistemas de lámparas ultravioletas, flujo
refrigerante variable y más.
Esta edición del Manual de Bolsillo de ASHRAE, que fue publicado primero en 1987, fue
recopilada por los editores administrativos de ASHRAE, los principales contribuyentes anteriores
fueron Carl W. MacPhee, Griffiith C. Burr, Jr., Harry E. Rountree y Frederick H. Kohloss.
A través de esta Guía de Bolsillo, fuentes originales de figuras y tablas son indicadas donde
es aplicable. Por motivos de espacio, una abreviatura de publicaciones de ASHRAE ha sido
adoptada. Las fuentes de ASHRAE son observadas como encabezamientos o títulos de tablas en
corchetes utilizando las siguientes abreviaturas:
Fig
Tbl
Ch
Std
2013F, 2009F, etc.
2012S, 2008S, etc.
2011A, 2007A, etc.
2010R, 2006R, etc.
Figura
Tabla
Capítulo
Norma de ASHRAE
Manual de ASHRAE—Fundamentos
Manual de ASHRAE—Sistemas y Equipos HVAC
Manual de ASHRAE—Aplicaciones HVAC
Manual de ASHRAE—Refrigeración
Entradas completas para todas las referencias citadas en las tablas y figuras están disponibles
en la publicación de la fuente original.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
viii
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
PREFACIO
01.fm Page 1 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
TRATAMIENTO DE AIRE Y PSICOMETRIAS
1
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.1 (I-P) Gráfico de Fricción para Conducto Redondo ( = 0.075 lbm/ft3 y  =0.0003 ft)
[2013F, Ch21, Fig 10]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
1.
01.fm Page 2 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
2
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.1 (SI) Gráfico de Fricción para Conducto Redondo ( = 1.20 kg/m3 y  = 0.09 mm)
[2013F, Ch21, Fig 10]
01.fm Page 3 Thursday, March 3, 2016 12:25 PM
Tabla 1.1 (SI)
Tratamiento de Aire y Psicometrias
Velocidad V, fpm
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
Pv = (V/4005)2
Presión de Velocidad Pv, in. H2O
0.01
0.01
0.02
0.02
0.03
0.04
0.05
0.06
0.08
0.09
0.11
0.12
0.14
0.16
0.18
0.2
0.22
0.25
0.27
0.3
0.33
0.36
0.39
Velocidades vs. Presiones de Velocidad
Presión de Velocidad, Pv, Pa
0.6
2.4
5.4
9.6
15.1
18.3
21.7
25.5
29.5
33.9
38.5
43.5
48.8
54.3
60.2
72.9
86.7
101.8
118.0
135
184
241
305
376
Pv = 0.602 V2
3
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Velocidad V, m/s
1.0
2.0
3.0
4.0
5.0
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
9.5
10.0
11.0
12.0
13.0
14.0
15.0
17.5
20.0
22.5
25.0
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.1 (I-P) Velocidades vs. Presiones de Velocidad
01.fm Page 4 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Diámetro hidráulico Dh = 4A/P, donde A = área de ducto (in.2 [mm]) y P = perímetro (in,
[mm]). Los ductos que tienen el mismo diámetro hidráulico tendrán aproximadamente la misma
resistencia de fluido a velocidades iguales.
Accesorios
La resistencia a fluir a través de accesorios puede ser expresada por la pérdida de ajuste de
coeficientes C. La pérdida de fricción en un accesorio en pulgadas de agua es CPv. Lo más radical
el flujo de aire es cambiado en dirección o velocidad, cuanto mayor sea el coeficiente de pérdida
del accesorio. Ver Base de Datos de Ajuste de Conductos de ASHRAE para una lista completa.
Codos biselados de 90° con álabes usualmente tendrán C entre 0.11 y 0.33.
Conductos Redondos Flexibles
Ductos flexibles no metálicos extendidos totalmente tienen pérdidas de fricción aproximadamente tres veces mayor que los conductos de acero galvanizado. Este se eleva rápidamente para
conductos no extendidos por un factor de corrección de 4 si es extendido el 70%, 3 si es extendido
el 80% y 2 si es extendido el 90%. Para relación de radio de curvatura central a diámetro de 1 a 4
el coeficiente de pérdida aproximado está entre 0.82 y 0.87.
Tabla 1.2 (I-P) Clasificación de Fugas de Conductos a
Tipo de Conducto
Fugas Predichas Clase CL
Sellado b,c
Sin Sellarc
Metal (excluido flexible)
Redondo y ovalado plano
3
30
(6 a 70)
Rectangular
2 pulg. de agua
12
>2 y 10 pulg. de agua
48
(12 a 110)
6
48
(12 a 110)c
(ambas presiones positiva y negativa)
Flexible
Metal, aluminio
8
30
(12 a 54)
Sin metal
12
30
(4 a 54)
Fibra de vidrio
Redondo
3
na
Rectangular
6
na
a Las
clases de fugas indicadas en esta tabla son promedios basados en pruebas conducidas por AISI/SMACNA
(1972), ASHRAE/SMACNA/TIMA (1985) y Swim and Griggs (1995).
b Las clases de fugas indicadas en la categoría sellado están basadas en los supuestos que para conductos de metal,
todas las juntas transversales, costuras y aberturas en la pared del conducto están sellados a presiones sobre 3 pulg.
de agua, que las juntas transversales y costuras longitudinales están selladas en 2 y 3 pulg. de agua, y que las juntas
transversales están selladas bajo 2 pulg. de agua. Las clases más bajas de sellado son obtenidas mediante selección
cuidadosa de juntas y métodos de sellados.
c Las clases de fugas asignadas anticipan cerca de 25 juntas por 100 pie lineal de conducto. Para sistemas con un alto
ajuste de relación de conducto recto, ocurren mayores fugas en ambas condiciones selladas y sin sellar.
4
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
(ambas presiones positiva y negativa)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Conductos No Circulares
01.fm Page 5 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Selladob,c
Tipo de Conducto
Sin Sellarc
Fuga Prevista
Clase CL
Tasa de Fuga
L(s·m2) a 250Pa
4
0.14
Fuga Prevista
ClaseCL
Tasa de Fuga
L(s·m2) a 250Pa
Metal (excluida flexible)
Redondo y ovalado plano
42
1.5
(8 a 99)
(0.3 a 3.6)
Rectangular
500 Pa
17
0.62
(ambas presiones positiva
y negativa)
>500 y 250 Pa
8
0.29
(ambas presiones positiva y
negativa)
68
2.5
(17 a 155)
(0.6 a 5.6)
68
2.5
(17 a 155)
(0.6 a 5.6)
Flexible
Metal, aluminio
11
No metálico
17
0.40
0.62
42
1.5
(17 a 76)
(0.6 a 2.8)
30
1.5
(6 a 76)
(0.2 a 2.8)
Fibra de vidrio
a
b
c
Redondo
4
0.14
na
na
Rectangular
8
0.29
na
na
Las clases de fugas indicadas en esta tabla son promedios basados en pruebas conducidas por AISI/SMACNA (1972),
ASHRAE/SMACNA/TIMA (1985) y Swim and Griggs (1995).
Las clases de fugas indicadas en la categoría sellado están basadas en los supuestos que para conductos metálicos, todas
las juntas transversales, costuras y aberturas en la pared del conducto son sellados a presiones sobre 750 Pa, que las juntas transversales y costuras longitudinales son selladas a 500 y 750 Pa y que juntas transversales son selladas bajo 500 Pa.
Clases de fugas menores son obtenidas por selección cuidadosa de juntas y métodos de sellado.
Las clases de fugas asignadas anticipan alrededor de 0.82 juntas por metro de conducto Para sistemas con un alto ajuste
de relación de conducto recto, fugas mayores ocurren en ambas condiciones selladas y sin sellar.
Tabla 1.3 (I-P) Clase de Fuga de Red de Conductos Recomendado por Tipo de Conducto
Clase de Fuga CL, cfm/100 pie2 a 1 pulg. de agua
Redondo
3
Ovalado
Plano
Rectangular
Flexible
3
6
6
Fibra de vidrio
Tabla 1.3 (SI)
Redondo
3
Rectangular
6
Clase de Fuga de Red de Conductos Recomendado por Tipo de Conducto
Tipo de Conducto
Clase de Fuga, CL, Tasa de Fuga, L/(s·m2) a 250 Pa
Metal
Redondo
4
0.14
Ovalado plano
4
0.14
Rectangular
8
0.29
8
0.29
Redondo
4
0.14
Rectangular
8
0.29
Flexible
Fibra de Vidrio
5
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tipo de Conducto
Metal (excluido flexible)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.2 (SI) Clasificación de Filtración de Conductoa
Clase de Fuga CL = Q/  PS0.65
donde
Q
=
 Ps =
tasa de fuga, cfm/100 pie2 (L/s/100 m2) área de superficie
diferencia de presión estática, pulgadas de agua (Pa) entre el interior y exterior del
conducto
Tabla 1.4
Niveles de Exigencia para Sellado de Conductos
Niveles de Sellado de Conductos
Exigencias de Selladoa
A
Todas las juntas transversales, costuras longitudinales y
penetraciones en la pared de los conductos
B
Todas las juntas transversales y costuras longitudinales
C
Sólo juntas transversales
a Juntas transversales son conexiones de dos conductos o elementos de ajuste orientados perpendicular para fluir. Costuras
longitudinales son juntas orientadas en la dirección de la corriente de aire. Penetraciones de la pared de los conductos son
aberturas hechas por tornillos, sujetadores no autosellantes, cañerías, tuberías, barras y cables. Costuras de bloqueo espiral redondas y ovaladas planas no necesitan ser selladas antes del ensamblaje, pero pueden ser recubiertas después del
ensamblaje para reducir fuga. Todas las otras conexiones son consideradas juntas transversales, incluido pero no limitado
a espines, enchufes y otras conexiones de ramales, acceso a marcos de puertas y conexiones de conductos a equipos.
Tabla 1.5
Recomendaciones para Sellado de Conductos
Tipo de Conducto
Niveles de Sellado de
Conducto Recomendado
Ubicación de Conducto
Suministro
2 pulg. (500 Pa) > 2 pulg. (500 Pa)
de agua
de agua
Retorno
A
A
A
A
Espacios no acondicionados
B
A
B
B
Espacios acondicionados
(conductos ocultos)
C
B
B
C
Espacios acondicionados
(conductos expuestos)
A
A
B
B
Tabla 1.6
Fuga de Conducto por Unidad de Longitud
Fuga de Costura Longitudinal
sin Sellar
Fuga, cfm por pie
(L por metro) Longitud de Costura
a 1 pulg. Presión de Agua
(a 250 Pa Presión Estática)
Tipo de Conducto/Costura
Margen
Promedio
Rectangular Bloqueo Pittsburgh
Calibre 26
0.01 a 0.02 (0.015 a 0.03)
0.0164 (0.025)
Calibre 22
0.001 a 0.002 (0.0015 a 0.003)
0.0016 (0.0025)
Cerradura de resorte botón
perforador
Redondo
Calibre 26
0.03 a 0,15 (0.05 a 0.23)
0.0795 (0,12)
Calibre 22
NA (1 prueba)
0.0032 (0.005)
Espiral (calibre 26)
NA (1 prueba)
0.015 (0.023)
Cerradura de resorte
0.04 a 0.14 (0.06 a 0.22)
0.11 (0.17)
Ranura
0.11 a 0.18 (0.17 a 0.28)
0.12 (0.19)
6
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Escape
Exteriores
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tratamiento de Aire y Psicometrias
01.fm Page 6 Thursday, March 3, 2016 12:25 PM
01.fm Page 7 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
7
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 1.2 A la Salida Coeficiente de Ajuste Co Afecta t Perdida [2013F, Ch 21, Fig.7]
4.4
4.9
4.0
5.0
6
6.6
7.6
8.4
9.1
9.8
10.4
11.0
11.5
12.4
13.2
14.0
14.7
15.3
15.9
16.5
17.1
17.6
18.1
3.8
3.0
Largo
Ady.b
6
8
10
12
14
16
18
20
24
28
32
36
40
44
48
52
56
60
64
4.0
Largo
Ady.b
8
8.7
9.8
10.7
11.4
12.2
12.9
13.5
14.6
15.6
16.5
17.4
18.2
18.9
19.6
20.2
20.9
21.5
22.0
7
8.2
9.1
9.9
10.8
11.3
11.9
12.6
13.5
14.5
15.3
16.1
16.8
17.5
18.1
18.7
19.3
19.8
20.3
5.2
4.6
4.0
4.5
10.4
11.3
12.2
13.0
13.7
14.4
15.6
16.7
17.7
18.6
19.5
20.3
21.0
21.7
22.4
23.0
23.6
9
5.5
4.9
4.2
5.0
10.9
12.0
12.9
13.7
14.5
15.2
16.5
17.7
18.8
19.8
20.7
31.5
22.3
23.1
23.8
24.5
25.1
10
5.7
5.1
4.4
5.5
12.6
13.5
14.4
15.3
16.0
17.4
18.7
19.8
20.9
21.8
22.7
23.6
24.4
25.2
25.9
26.6
11
6.0
5.3
4.6
6.0
7.5
5.1
5.8
6.7
7.0
4.9
5.7
6.4
6.9
6.1
5.2
8.0
7.3
6.4
5.5
9.0
7.6
6.7
5.7
10.0
13.1
14.2
15.1
16.0
16.8
18.3
19.6
20.8
21.9
22.9
23.9
24.8
25.7
26.5
27.3
28.0
14.7
15.7
16.7
17.5
19.1
20.5
21.8
22.9
24.0
25.0
26.0
26.9
27.7
28.6
29.3
15.3
16.4
17.3
18.2
19.9
21.3
22.7
23.9
25.0
26.1
27.1
28.0
28.9
29.8
30.6
16.9
17.9
18.9
20.6
22.1
23.5
24.8
26.0
27.1
28.2
29.2
30.1
31.0
31.9
17.5
18.5
19.5
21.3
22.9
24.4
25.7
27.0
28.1
29.2
30.3
31.2
32.2
33.1
19.1
20.1
22.0
23.7
25.2
26.6
27.9
29.1
30.2
31.3
32.3
33.3
34.3
19.7
20.7
22.7
24.4
26.0
27.4
28.8
30.0
31.2
32.3
33.4
34.4
35.4
21.3
23.3
25.1
26.7
28.2
29.6
30.9
32.2
33.3
34.4
35.5
36.5
Longitud de un Lado del Conducto Rectangular (a), pulg.
12
13
14
15
16
17
18
19
6.2
5.5
4.7
6.5
20
8.0
7.0
6.0
11.0
21.9
34.9
25.8
27.5
29.0
30.5
31.8
33.1
34.3
35.4
36.5
37.6
Longitud de un Lado de Conducto Rectangular (a), pulg.
25.1
27.1
28.9
30.5
32.1
33.5
34.9
36.2
37.4
38.5
39.6
22
8.3
7.3
6.2
24
26.2
28.3
30.2
32.0
33.6
35.1
36.6
37.9
39.2
40.4
41.6
12.0
26
29.5
31.5
33.3
35.1
36.7
38.2
39.6
41.0
42.3
43.5
8.6
7.6
6.4
13.0
30.6
32.7
34.6
36.4
38.1
39.7
41.2
42.7
44.0
45.3
28
8.9
7.8
6.6
14.0
33.9
35.9
37.8
39.5
41.2
42.8
44.3
45.7
47.1
30
9.1
8.0
6.8
15.0
Largo
Ady.b
6
8
10
12
14
16
18
20
24
28
32
36
40
44
48
52
56
60
64
9.4
8.3
7.0
16.0
Tratamiento de Aire y Psicometrias
Tabla 1.7 (I-P) Equivalentes Circulares de Conducto Regular para Igualdad de Fricción y Capacidada
01.fm Page 8 Thursday, March 3, 2016 12:25 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
8
32
35.0
37.1
39.0
40.9
42.6
44.3
45.8
47.3
48.7
50.1
51.4
52.7
53.9
55.1
56.3
57.4
58.4
38.2
40.3
42.2
44.0
45.7
47.3
48.9
50.4
51.8
53.2
54.5
55.8
57.0
58.2
59.3
60.5
39.4
41.5
43.5
45.3
47.1
48.8
50.4
51.9
53.4
54.8
56.2
57.5
58.8
60.1
61.3
62.4
42.6
44.7
46.6
48.4
50.2
51.9
53.5
55.0
56.5
57.9
59.3
60.6
61.9
63.1
64.3
43.7
45.8
47.9
49.7
51.6
53.3
54.9
56.5
58.0
59.5
60.9
62.3
63.6
64.9
66.2
50.2
52.2
54.2
60.0
57.8
59.4
61.1
62.6
64.1
65.6
67.0
68.4
69.7
duct (b), in.
48.1
49.1
51.0
52.9
54.7
56.4
58.0
59.6
61.1
62.6
64.0
65.4
66.7
68.0
51.4
53.4
55.4
57.3
59.1
60.8
62.5
64.1
65.7
67.2
68.7
70.1
71.5
52.5
54.6
56.6
58.6
60.4
62.2
63.9
65.6
67.2
68.7
70.2
71.7
73.1
55.7
57.8
59.8
61.7
63.6
65.3
67.0
68.7
70.3
71.8
73.3
74.8
56.8
59.0
61.0
63.0
64.9
66.7
68.4
70.1
71.7
73.3
74.9
76.3
61.2
63.4
65.4
67.4
69.3
71.1
72.9
74.6
76.3
77.9
79.4
65.6
67.7
69.8
71.8
73.7
75.4
77.3
79.1
80.8
82.4
70.0
72.1
74.2
76.2
78.1
80.0
81.8
83.5
85.3
74.3
76.5
78.6
80.6
82.5
84.4
86.2
88.0
78.7
80.9
82.9
85.0
86.9
88.8
90.7
83.1
85.2
87.3
89.3
91.3
93.2
87.5
89.6
91.7
93.7
95.7
91.8
94.0
96.1
98.1
Tabla 1.7 (I-P) Equivalentes Circulares de Conducto Regular para Igualdad de Fricción y Capacidada (Continuo)
Longitud de un Lado del Conducto Rectangular (a), pulg.
34
36
38
40
42
44
46
48
50
52
56
60
64
68
72
76
80
84
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
a Tabla basada en D = 1.30 (ab)0.625/(a + b)0.25
e
b Longitud del lado adyacente del conducto rectangular
Largo
Ady.b
32
36
40
44
48
52
56
60
64
68
72
76
80
84
88
92
96
01.fm Page 9 Thursday, March 3, 2016 12:25 PM
Largo
Ady.b
32
36
40
44
48
52
56
60
64
68
72
76
80
84
96.2
88
98.4
92
100.5 96
88
Tratamiento de Aire y Psicometrias
9
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Largo
Adyb 100
100
109
150
133
200
152
250
169
300
183
400
207
500
227
600
245
700
261
800
275
900
289
1000 301
1200 324
1400 344
1600 362
1800 379
2000 395
2200 410
2400 424
2600 437
2800 450
150
164
189
210
229
260
287
310
331
350
367
384
413
439
463
485
506
525
543
560
577
125
150
172
190
207
235
258
279
298
314
330
344
370
394
415
434
453
470
486
501
516
204
228
248
283
313
339
362
383
402
420
453
482
508
533
555
577
597
616
634
175
219
244
266
305
337
365
391
414
435
454
490
522
551
577
602
625
647
688
688
259
283
325
360
390
418
442
465
486
525
559
591
619
646
671
695
717
738
225
273
299
343
381
414
443
470
494
517
558
595
629
660
688
715
740
764
787
314
361
401
436
467
496
522
546
590
629
665
698
728
757
784
810
834
328
378
420
457
490
520
548
574
620
662
700
735
767
797
826
853
879
409
455
496
533
567
597
626
677
724
766
804
840
874
905
935
964
437
488
533
573
609
643
674
731
781
827
869
908
945
980
1012
1043
518
567
610
649
686
719
780
835
885
930
973
1013
1050
1085
1119
547
598
644
687
726
762
827
886
939
988
1034
1076
1116
1154
1190
628
677
722
763
802
872
934
991
1043
1092
1137
1180
1220
1259
Longitud de un lado del Conducto Rectangular (a), mm.
250
275
300
350
400
450
500
550
656
708
755
799
840
914
980
1041
1096
1147
1195
1241
1283
1324
600
737
787
833
876
954
1024
1088
1146
1200
1251
1299
1344
1387
650
765
818
866
911
993
1066
1133
1195
1252
1305
1355
1402
1447
700
847
897
944
1030
1107
1177
1241
1301
1356
1409
1459
1506
750
875
927
976
1066
1146
1219
1286
1348
1406
1461
1513
1562
800
984
1037
1133
1220
1298
1371
1438
1501
1561
1617
1670
900
Tratamiento de Aire y Psicometrias
Equivalentes Circulares de Conducto Rectangular para Friccion Igual y Capacidada
200
Tabla 1.7 (SI)
01.fm Page 10 Thursday, March 3, 2016 12:25 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
10
1200
1312
1365
1416
1464
1511
1555
1598
1640
1680
1719
1756
1793
1828
1862
1896
1929
1961
1992
1100
1202
1256
1306
1354
1400
1444
1486
1527
1566
1604
1640
1676
1710
1744
1776
1808
1839
1869
1898
1421
1475
1526
1574
1621
1667
1710
1753
1793
1833
1871
1909
1945
1980
2015
2048
2081
1300
Tabla 1.7 (SI)
1530
1584
1635
1684
1732
1778
1822
1865
1906
1947
1986
2024
2061
2097
2133
2167
1400
1749
1803
1854
1904
1952
1999
2044
2088
2131
2173
2213
2253
2292
2329
1858
1912
1964
2014
2063
2110
2155
2200
2243
2285
2327
2367
2406
1968
2021
2073
2124
2173
2220
2266
2311
2355
2398
2439
2480
2077
2131
2183
2233
2283
2330
2377
2422
2466
2510
2552
2186
2240
2292
2343
2393
2441
2487
2533
2578
2621
2296
2350
2402
2453
2502
2551
2598
2644
2689
2405
2459
2511
2562
2612
2661
2708
2755
2514
2568
2621
2672
2722
2771
2819
Longitud de un lado del Conducto Rectangular (a), mm.
1600 1700 1800 1900 2000 2100 2200 2300
duct (b), mm.
1640
1693
1745
1794
1842
1889
1933
1977
2019
2060
2100
2139
2177
2214
2250
1500
2624
2678
2730
2782
2832
2881
2400
2733
2787
2840
2891
2941
2500
2842
2896
2949
3001
2600
2952
3006
3058
2700
Equivalentes Circulares de Conducto Rectangular para Friccion Igual y Capacidada (Continuo)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
a Tabla basada en D = 1.30 (ab)0.625/(a + b)0.25.
e
b Longitud del lado adyacente de conducto rectangular
Largo
Ady.b 1000
1000 1093
1100 1146
1200 1196
1300 1244
1400 1289
1500 1332
1600 1373
1700 1413
1800 1451
1900 1488
2000 1523
2100 1558
2200 1591
2300 1623
2400 1655
2500 1685
2600 1715
2700 1744
2800 1772
2900 1800
01.fm Page 11 Thursday, March 3, 2016 12:25 PM
3061
3115
2800
3170
2900
Tratamiento de Aire y Psicometrias
11
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
8
9
11
12
15
19
22
3
7
9
10
12
13
15
18
20
21
4
8
10
—
11
13
14
18
19
21
5
8
9
—
11
12
14
15
17
19
20
23
25
28
30
33
36
39
45
52
59
6
10
—
12
13
15
16
18
20
21
23
—
—
—
—
—
—
—
10
—
11
13
14
16
17
—
19
21
22
24
27
30
35
39
12
—
14
15
—
17
18
20
22
23
—
—
—
12
—
13
15
16
—
18
19
21
24
27
30
12
14
—
15
17
18
20
21
25
11
14
—
16
17
—
19
22
24
—
17
19
22
14
19
16
Diametro de
Conducto
Circular, pulg
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
40
42
44
9
—
—
—
—
—
—
8
46
50
58
65
71
77
34
38
43
48
52
57
63
70
76
10
26
29
31
34
36
39
40
44
47
51
55
58
61
64
67
77
20
35
38
39
42
46
47
50
53
57
60
69
75
82
22
37
40
41
44
46
49
52
55
62
68
74
24
Tratamiento de Aire y Psicometrias
Eje Menor a, pulg.
11 12 14 16 18
Eje Mayor A, pulg.
— 28 23 21
— 31 27 24 21
— 34 28 25 23
— 37 31 29 26
— 42 34 30 27
— 45 38 33 29
— 50 41 36 32
— 56 45 38 34
— 59 49 41 37
65 52 46 40
72 58 49 43
78 61 54 46
81 67 57 49
71 60 53
77 66 56
69 59
76 65
79 68
71
78
Equivalente de Dimensiones de Ducto Ovalado Plano* [2013F, Ch 21, Tbl 3]
Eje Menor a, pulg.
7
8
9
10
Eje Mayor A, pulg.
Tabla 1.8 (I-P)
*Tabla basada en De = 1.30 (ab)0.625/(a + b)0.25.
Diametro de
Conducto
Circular, pulg
5
5.5
6
6.5
7
7.5
8
8.5
9
9.5
10
10.5
11
11.5
12
12.5
13
13.5
14
14.5
15
16
17
18
01.fm Page 12 Thursday, March 3, 2016 12:25 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
12
205
265
360
475
70
(ab)0.625/(a
180
235
300
380
490
100
+
b)0.25.
190
235
290
375
475
125
200
245
305
385
485
635
840
1115
1490
150
215
—
325
410
525
—
—
—
175
240
290
360
—
580
760
995
1275
1680
200
—
—
#
—
—
—
—
#
285
345
425
530
675
845
1085
1425
275
325
395
490
—
—
—
—
375
460
570
700
890
1150
1505
435
535
655
820
1050
1370
1800
Eje Menor a, mm
300
325
350
Eje Mayor A, mm
505
615
765
970
1260
1645
2165
375
580
720
905
1165
1515
1985
400
810
1025
1315
1705
2170
450
500
1170
1500
1895
2455
Equivalente de Dimensiones de Ducto Ovalado Plano* [2013F, Ch 21, Tbl 3]
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
*Tabla basada en De = 1.30
125
140
160
180
200
224
250
280
315
355
400
450
500
560
630
710
800
900
1000
1120
1250
Diametro de
Conducto
Circular, pulg
Tabla 1.8 (SI)
01.fm Page 13 Thursday, March 3, 2016 12:25 PM
1065
1350
1690
2170
2795
550
1950
2495
600
Tratamiento de Aire y Psicometrias
13
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
01.fm Page 14 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Velocidades de Diseño Típico para Componentes HVAC
Rejillas
Entrada
7000 cfm (3300 L/s) y mayor
Menos que 7000 cfn (3300L/s)
Escape
5000 cfm (24000 L/s) y mayor
Menos que 5000 cfm (2400 L/s)
Filtros
Filtros de panel
Impacto viscoso
Tipo seco, superficie extendida
Plana (baja eficiencia)
Medios plisados (eficiencia
intermedia)
HEPA
Filtros medios renovables
Cortina en movimiento impacto
viscoso
Cortina en movimiento medios
secos
Depurador de aire electrónico
Tipo ionizante
Bobinas de calefacción
Vapor y agua caliente
400 (2)
Ver figura de abajo
500 (2.5)
Ver figura de abajo
200 a 800 (1 a 4)
Velocidad de Conducto
Hasta 750 (3.8)
250 (1.3)
500 (2.5)
200 (1)
150 a 350 (0.8 a 1.8)
500 a 1000 (2.5 a 5)
200 (1) min. 1500 (8) max.
Referir a datos mfg.
Referir a datos mfg.
400 a 500 (2 a 3)
Referir a datos mfg.
Referir a datos mfg.
1200 a 1800 (6 a 9)
Parámetros Pertinentes Utilizados en Establecer Figura
Parámetro
Parámetro
Parámetro
de Admisión
Escape
Área Mínima Libre (48-pulg.
(1220-mm) Sección de Prueba
45
45
Cuadrado). %
Inapreciable
Penetración de agua.
No
[menos de
oz/(ft2/0.25 h) [µL/(m2 . s)]
aplicable
0.2 (0.6)]
Caida de presión estática máxima,
0.15 (35)
0.25 (60)
pulg. de agua (Pa)
14
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Eléctrico
Cable abierto
Aletas tubular
Bobinas de deshumidificación
Depuradores de aire
Tipo aerosol
Tipo celda
Tipo aerosol de alta velocidad
Velocidad Frontal, fpm (m/s)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.9
Elemento de Conducto
01.fm Page 15 Thursday, March 3, 2016 12:25 PM
Variables Dependientes
Variables Independentes
Q1 = Q2
1b
Press.1 = Press.2a
 D 1 2  N 1 2
  -------   -------
 D 2
 N 2
1
 -----2
1c
W1 = W2
 D 1 5  N 1 3
  -------   -------
 D 2
 N 2
1
 -----2
2a
Q1 = Q2
 D  2  Press.  1/2
  ------1-   ----------------1-
 D 2
 Press. 2
   1/2
  -----2-
  1
2b
N1 = N2
 D   Press.  1/2
  ------2-   ----------------1-
 D 1  Press. 2
   1/2
  -----2-
  1
2c
W1 = W2
 D  2  Press.  3/2
  ------1-   ----------------1-
 D 2
 Press. 2
   1/2
  -----2-
  1
3a
N1 = N2
D 3 Q
  ------2-  ------1Q2
 D 1
 
3b
Press.1 = Press.2
 D 2 4  Q 1 2
  -------   -------
 D 1
 Q 2

 -----12
3c
W1 = W2
D  4 Q  3
  ------2-   ------1-
 Q 2
 D 1
1
 -----2
 
1 denota que el variable es para el ventilador bajo consideración
2 denota que el variable es para el ventilador probado
A menos que se identifique de otro modo, los datos de rendimiento del ventilador están basados en aire seco en condiciones estándar 14.696 psi y 70°F (0.075 lbm/pie3) [101.325 kPa y 20°C (1.204 kg/m3)]. En aplicaciones actuales, el
ventilador puede ser requerido para utilizar aire o gas en alguna otra densidad. El cambio en densidad puede ser
debido a temperatura, composición del gas o altitud. Como indicado en las Leyes del Ventilador, el rendimiento del
ventilador es afectado por la densidad del gas. Con tamaño constante y velocidad, los caballos de fuerza y presión
varían directamente como la relación de la densidad del gas a la densidad del aire estándar.
La aplicación de las Leyes del Ventilador para un cambio en velocidad del ventilador, N, para
un ventilador de tamaño específico está mostrado en la Figura 1.3. La curva Pt computarizada es
derivada de la curva de base. Por ejemplo, punto E(N1 = 650) es computarizada del punto D (N2 =
600) como sigue:
En Punto D,
Q2 = 6 cfm y P t f
2
= 1.13 pulg. agua (Q1 = 3 m3/s y P t f
= 228 Pa)
2
Utilizando Ley de Ventilador 1a en Punto E
Q1 = 6000 (650/600) = 6500 cfm (Q1 = 3 × 650/600 = 3.25 m3/s)
15
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
1a
 D 1 3 N 1
  -------  ------N2
 D 2
a El subíndice
b El subíndice
cP oP
tf
sf .
Tratamiento de Aire y Psicometrias
No.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.10 Leyes de Ventilación a,b
Para todas las leyes de ventilación:
t1 = t2 y (punto de capacidad)1 = (punto de capacidad)2
01.fm Page 16 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
= 1.13 × (650/600)2 = 1.33 psi
1
(I-P)
[P t f
= 228 × (650/600)2 = 268 Pa]
(SI)
1
La curva completada P t f , N = 650 por tanto puede ser generado computando puntos adicio1
nales de los datos en la curva base, tal como el punto G desde el punto F.
hp =
cfm × presión estática, pulg. de agua
Eficiencia del ventilador (decimal) × 6356
L/s  diferencia de presión, kPa
Ventilador de potencia, kW = --------------------------------------------------------------------------------------------------------------------------------40350  eficiencia de ventilador  eficiencia de motor
Figura 1.3 (SI) Ejemplo de Cálculo de Leyes del Ventilador [2012S, Ch 21, Fig. 4]
16
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
(SI)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.3 (I-P) Ejemplo de Cálculo de Leyes del Ventilador [2012S, Ch 21, Fig. 4]
(I-P)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Utilizando Ley de Ventilador 1b
Pt f
01.fm Page 17 Thursday, March 3, 2016 12:25 PM
Superficie
Aerodinamica
Inclinado Hacia Atras
Curvado Hacia Atrás
Enchufe de Pleno
Ventiladores impelentes y de enchufe típicamente utilizan aletas,
impulsores inclinados hacia atrás o curvados hacia atrás en una
configuración de entrada simple. Los beneficios relativos de cada
impulsor son los mismos como aquellos descritos para ventiladores
de cubierta espiral.
Propulsor
Baja eficiencia.
Limitado a aplicaciones de presión baja.
Usualmente los impulsores de bajo costo tienen dos o más álabes de
espesor simple adjunto a un relativamente pequeño cubo.
La energía primaria es transferida por presión de velocidad.
Tubo Axial
Algo más eficiente y capaz de desarrollar más presión estática útil que
ventiladores de hélice.
Usualmente tiene de 4 a 8 aletas con perfil aerodinámico o sección
transversal de espesor único.
El cubo es usualmente menos de la mitad que el diámetro de la punta
del ventilador.
Alabe Axial
Buen diseño de la paleta da capacidad de presión media a alta en
buena eficiencia. Más eficiente tiene aletas de perfil aerodinámico.
Las aletas pueden tener fijo, controlable o paso controlable.
El cubo es usualmente más grande que la mitad del diámetro de la
punta del ventilador.
Tubo cilíndrico con despeje cercano a las puntas de la paleta.
Aletas guiadoras corriente arriba o corriente abajo del impulsor
aumentan la capacidad de presión y eficiencia.
Flujo Mixto
Flujo Mixto
Combinación de las características axial y centrífuga. Idealmente
adecuado en aplicaciones en la cual el aire tiene que circular dentro
y fuera axialmente. Características de presión más alta que los
ventiladores axiales.
La mayoría de ventiladores de circulación mixta están en una
cubierta tubular e incluyen aletas de giro de salida. Pueden
operar sin cubierta o en un tubo y el conducto.
Flujo Cruzado
Flujo Cruzado (Tangencial)
Impulsor con aletas curvadas hacia adelante. Durante la rotación el
flujo de aire pasa a través de parte de las aletas del rotor dentro del
rotor. Esto crea un área de turbulencia el cual, trabajando con el
sistema de guía, desvía la corriente de aire a través de otra sección
del rotor dentro del ducto de descarga de la cubierta del ventilador.
Eficiencia más baja de cualquier tipo de ventilador.
Diseño especial de cubierta para 90° o recto a través de la
corriente de aire.
Centrifugo Tubular
Rendimiento similar a ventiladores curvados hacia atrás excepto que
capacidad y presión son más bajos. Eficiencia más baja que
ventiladores curvados hacia atrás. La curva de rendimiento puede
tener una inclinación hacia la izquierda del pico de presión,
Tubo cilíndrico similar al ventilador de paleta axial, excepto que
la distancia a la rueda no está tan cerca. El aire descarga
radialmente de la rueda y gira 90° para fluir a través de las
aletas guiadoras.
Centrifugo
Sistemas de escape de baja presión como fábrica general, cocina,
bodega y algunas instalaciones comerciales.
Provee ventilación de evacuación positiva, lo cual es una ventaja sobre
unidades de evacuación de tipo de gravedad. Las unidades
centrífugas son un poco más silenciosas que las unidades axiales.
Cubiertas normales no son usadas, debido a que el aire descarga
del impulsor en círculo completo. Usualmente no incluye
configuración para recuperar presión de velocidad del
componente.
Sistemas de escape de baja presión como fábrica general, cocina,
bodega y algunas instalaciones comerciales.
Provee ventilación de evacuación positiva, lo cual es una ventaja sobre
unidades de evacuación de tipo de gravedad. La cubierta protege al
ventilador del tiempo y actúa como protección de seguridad.
Esencialmente, un ventilador de hélice montado en una
estructura de soporte. Descargas de aire desde espacio anular
en parte inferior de cubierta de tiempo.
Otros Diseños
Ventiladores Axiales
Ventiladores Centrifugos
Radial (R)—
Radial—La Boquilla
Curvado
Hacia Adelante
Curva de presión plana y eficiencia más baja que la aleta, curvado
hacia atrás e in clinado hacia atrás.
No tasar el ventilador en la inclinación de la curva a la izquierda de la
presión estática de pico.
La potencia aumenta continuamente hacia la entrega gratuita.
Ventiladores de Techo de Potencia
Características de presión más alta que las aletas aerodinámicas,
curvadas hacia atrás y ventiladores inclinados hacia atrás.
La curva puede tener una distancia a la izquierda de la presión de pico
y el ventilador no debe ser operado en esta área.
La potencia aumenta continuamente hacia la entrega gratuita.
Diseño de espiral para conversión eficiente de presión de
velocidad a presión estática.
La eficiencia máxima requiere despeje cerca y alineación entre
rueda y entrada.
Utiliza la misma configuración de cubierta como el diseño de
aletas aerodinámicas.
El espiral similar a y a menudo idéntico a otros diseños de
ventilador centrífugo.
Encaja entre la rueda y entrada no es tan crítico como para aletas
y ventiladores inclinados hacia atrás.
El espiral similar a y a menudo idéntico a otros diseños de
ventilador centrífugo.
Encaja entre la rueda y entrada no es tan crítico como para aletas
y ventiladores inclinados hacia atrás.
Ventiladores impelentes y de enchufe son únicos en que ellos son
operados sin cubierta. El equivalente de una cubierta o cámara
impelente (línea de puntos), depende de la aplicación.
Los componentes del sistema de accionamiento para el
ventilador de enchufe están situados fuera de la corriente de
aire.
Anillo circular simple, placa de orificio o venturi.
Diseño óptimo es próximo a las puntas de las aletas y forma
superficie aerodinámica lisa en las ruedas.
Tubo cilíndrico con distancia cerca a la punta de la paleta.
17
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Aletas de espesor sencillo curvado o inclinado lejos de la dirección de
rotación.
Eficientes por las mismas razones como ventilador de aletas
aerodinámicas.
Axial
Diseño de Cubierta
Aletas de contorno de perfil aerodinámico curvado lejos de la
dirección de rotación. Aletas profundos permiten expansión
eficiente entre el trayecto de los álabes.
El aire sale del rotor a una velocidad inferior a la velocidad punta.
Para servicio dado, tener la velocidad más alta de diseños del
ventilador centrífugo.
Tratamiento de Aire y Psicometrias
Diseño del Rotor
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.11 Tipos de Ventiladores [2012S, Ch 21, Tbl 1]
Tipo
01.fm Page 18 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Características de Rendimiento
Aplicaciones
La más alta eficiencia de todos los diseños de ventiladores centrífugos
Aplicaciones generales de calefacción, ventilación y aire acondicionado.
y las eficiencias de pico ocurren en 50 a 60% de volúmenes muy
Usualmente sólo es aplicado a sistemas grandes, que pueden ser aplicaciones
abiertos.
de presión baja, media o alta.
El ventilador no tiene características de sobrecarga, lo que significa
Aplicado a grandes operaciones industriales de aire limpio para ahorro de
que la potencia alcanza la eficiencia máxima cerca del pico y se
energía significante.
vuelve más bajo, o auto limitado hacia la entrega gratis.
Similar ventiladores de aletas aerodinámicas, excepto eficiencia de
pico ligeramente bajo.
Aletas curvadas son ligeramente más eficientes que las aletas rectas.
Las mismas aplicaciones de calefacción, ventilación y aire acondicionado que
el ventilador de aletas aerodinámicas.
Utilizados en algunas aplicaciones industriales donde el ambiente puede
corroer o erosionar aletas aerodinámicas.
Características de presión más alta que ventiladores aerodinámicos y
curvados hacia atrás. La presión puede descender de repente a la
izquierda de la presión de pico, pero esto usualmente no causa
problemas.
La potencia se eleva continuamente para entrega libre, lo cual es una
característica de sobrecarga.
Aletas curvadas son ligeramente más eficientes que las aletas rectas.
Principalmente para materiales que se manejan en plantas industriales.
También para algunos requisitos industriales de alta presión. La rueda fuerte
es fácil de reparar en el campo. La rueda algunas veces recubierta con
material especial.
No común para aplicaciones de calefacción, ventilación y aire acondicionado
(HVAC).
Curva de presión menos pronunciada que la de los ventiladores
curvados hacia atrás.
La más alta eficiencia se produce en 40 a 50% de volumen abierto.
Operar el ventilador a la derecha de la presión del pico. La potencia
aumenta continuamente para descarga gratis lo cual es una
característica de sobrecarga.
Principalmente para aplicaciones de baja presión de calefacción, ventilación y
aire acondicionado (HVAC) como hornos residenciales, unidades de
estación central y acondicionadores de aire.
Ventiladores impelentes y de enchufe son similares a ventiladores
cubiertos de aletas aerodinámicas curvadas hacia atrás, pero
generalmente son menos eficientes debido a la conversión
ineficiente de energía cinética en la descarga de corriente de aire.
Son más susceptibles a la degradación de rendimiento causado por
mala instalación.
Ventiladores impelentes y de enchufe son utilizados en una variedad de
aplicaciones de calefacción, ventilación y aire acondicionado (HVAC) como
transportadores de aire, especialmente donde arreglos de accionamiento
directo son deseables. Otras ventajas de estos ventiladores son la
configuración de descarga, flexibilidad y potencial para unidades más
pequeñas.
Velocidad de circulación alta, pero capacidades de presión muy bajas. Para aplicaciones de baja presión, movimiento de aire de alto volumen, como
circulación de aire en un espacio o ventilación a través de una pared sin
La eficiencia máxima alcanzada cerca de descarga gratis. Descarga
tuberías. Utilizado para recuperar aplicaciones de aire.
de patrón circular y remolinos de corriente de aire.
Aplicaciones de baja y media presión para conductos de calefacción,
Velocidad de circulación alta, capacidades de presión media. La curva
refrigeración y aire acondicionado (HVAC) donde la distribución del aire
de presión se inclina hacia la izquierda de la presión de pico. Evite
corriente abajo no es crítica.
operar el ventilador en esta región. Descarga de patrón circular rota
Utilizado en aplicaciones industriales como hornos de secado, pintar cabinas y
o arremolina.
escapes de humos.
El sistema general de calefacción, refrigeración y aire acondicionado (HVAC)
en aplicaciones de presión baja, media y alta donde flujo recto e instalación
compacta son requeridos.
Tiene buena distribución del aire aguas abajo.
Tiene en aplicaciones industriales en lugar de ventiladores tubo axial.
Ventiladores más compactos que centrífugos para el mismo servicio.
Característica de curva de presión entre ventiladores axiales y
ventiladores centrífugos. Presión más alta que ventiladores axiales
y flujo de volumen más alto que ventiladores centrífugos.
Aplicaciones similares de calefacción, refrigeración y aire acondicionado
(HVAC) a ventiladores centrífugos o en aplicaciones donde un ventilador
axial no puede generar suficiente aumento de presión.
Similar a ventiladores curvados hacia adelante. La potencia aumenta
continuamente para descarga gratis, lo cual es una característica de
Sistemas de baja presión de calefacción, refrigeración y aire acondicionado
sobrecarga.
(HVAC), como calentadores de ventilador, rellenos de chimenea, enfriador
Diferente a todos los otros ventiladores, las curvas de rendimiento
electrónico y cortinas de aire.
incluyen las características del motor. Eficiencia más baja de
cualquier tipo de ventilador.
Rendimiento similar a ventilador curvado hacia atrás, excepto que
capacidad y presión son bajas.
Principalmente para presión baja, sistemas de aire de retorno en aplicaciones
Eficiencia más baja que el ventilador curvado hacia atrás porque el
de calefacción, refrigeración y aire acondicionado (HVAC).
aire gira a 90°.
Tiene flujo recto.
La curva de rendimiento de algunos diseños es similar al ventilador de
flujo axial y se inclina hacia la izquierda de la presión de pico.
Usualmente operado sin tuberías; por consiguiente opera a presión
muy baja y volumen alto.
Unidades centrífugas son de alguna manera más silenciosos que las unidades
de flujo axial. Sistemas de evacuación de baja presión, como factoría
general, cocina, bodega y algunas instalaciones comerciales. Bajo costo
inicial y costo de operación bajo da una ventaja sobre sistemas de
evacuación de flujo de gravedad.
Usualmente operado sin tuberías; por consiguiente opera a presión
muy baja y volumen alto
Sistemas de evacuación de baja presión, como factoría general, cocina, bodega
y algunas instalaciones comerciales. Bajo costo inicial y costo de operación
bajo da una ventaja sobre sistemas de evacuación de flujo de gravedad.
*Estas curvas de rendimiento reflejan las características generales de varios ventiladores como es aplicado comúnmente. No están destinados para proporcionar criterios de selección completo,
porque otros parámetros como diámetro y velocidad no son definidos.
18
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Características de alta presión con capacidades de flujo de medio
volumen. La curva de presión se inclina hacia la izquierda de la
presión de pico. Evite operar el ventilador en esta región.
Las aletas guiadoras corrigen el movimiento circular impartido por el
impulsor y mejora las características de presión y eficiencia del
ventilador.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.11 Tipos de Ventiladores [2012S, Ch 21, Tbl 1] (Cotinuado)
Curvas de Rendimiento*
01.fm Page 19 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Figura 1.4 Ventilador Deficiente/Rendimiento del Sistema
19
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
La Figura 1.4 ilustra ventilador deficiente/rendimiento del sistema. Las pérdidas de presión
del sistema han sido determinadas con precisión y un ventilador ha sido seleccionado para
operación en el punto 1. Sin embargo, ninguna concesión ha sido hecha para efectos de conexiones del sistema al ventilador o rendimiento del ventilador. Para compensar, un efecto al sistema
del ventilador debe ser agregado a las pérdidas de presión del sistema calculadas para determinar
la curva del sistema actual. El punto de intersección entre la curva de rendimiento de ventilador y
curva del sistema actual es punto 4. El volumen del flujo actual es, por consiguiente, deficiente
por la diferencia de 1 a 4. Para lograr el volumen de flujo de diseño, una pérdida de presión del
sistema de ventilación igual a la diferencia de presión entre los puntos 1 y 2 debe ser agregada a
las pérdidas de presión del sistema calculadas y el ventilador debe ser seleccionado para operar en
el punto 2.
Para rendimiento nominal, el aire debe entrar al ventilador uniformemente sobre el área de
entrada en una dirección axial sin pre-rotación.
Ventiladores sin impelentes y armarios o próximos a paredes deben estar localizados de tal
forma que el aire pueda fluir sin obstrucción en las entradas.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Efectos del Sistema de Ventilación
01.fm Page 20 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
20
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.5 (I-P) Carta Psicométrica para Temperatura Normal, Nivel del Mar [2013F, Ch 1, Fig. 1]
01.fm Page 21 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
21
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 1.5 (SI) Carta Psicométrica para Temperatura Normal, Nivel del Mar [2013F, Ch 1, Fig. 1]
01.fm Page 22 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
22
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Procesos de Aire Acondicionado
01.fm Page 23 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
23
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
01.fm Page 24 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
24
01.fm Page 25 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
25
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Tabla 1.12 (I-P)
Entalpia de Aire Húmedo en Presión Atmosférica Estándar,
14.696 psia [2013F, Ch 1, Tbl 2, Abreviada]
Entalpia, Btu/lbda
Temp.,°F
Entalpia, Btu/lbda
–80
–19.213
79
42.634
–70
–16.804
80
43.701
–60
–14.390
81
44.794
–50
–11.966
82
45.914
–40
–9.524
83
47.062
–30
– 7.052
84
48.239
–20
–4.527
85
49.445
–15
–3.234
86
50.682
–10
–1.915
87
51.950
–5
–0.561
88
53.250
0
0.835
89
54.584
5
2.286
90
55.952
10
3.803
91
57.355
15
5.403
92
58.795
20
7.106
93
60.272
25
8.934
94
61.787
30
10.916
95
63.343
35
13.009
96
64.039
40
15.232
97
66.578
45
17.653
98
68.260
50
20.306
99
69.987
55
23.229
100
71.761
60
26.467
110
92.386
65
30.070
120
119.615
70
34.097
130
156.077
71
34.959
140
205.828
72
35.841
150
275.493
73
36.744
160
376.736
74
37.668
170
532.269
75
38.015
180
793.142
76
39.584
190
1303.297
77
40.576
200
2688.145
78
41.593
26
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tratamiento de Aire y Psicometrias
01.fm Page 26 Thursday, March 3, 2016 12:25 PM
01.fm Page 27 Thursday, March 3, 2016 12:25 PM
Temp., °C
Entalpia Específica,
kJ/kgda
–60
–60.325
26
80.801
–55
–55.280
27
85.281
–50
–50.222
28
89.979
–45
–45.144
29
94.882
–40
–40.031
30
100.009
–35
–34.859
31
105.372
–30
–29.593
32
110.985
–25
–24.181
33
116.860
–20
–18.542
34
123.013
–10
–6.070
35
129.458
–8
–3.282
36
136.213
–6
–0.356
37
143.294
–4
2.728
38
150.720
–2
5.995
39
158.510
0
9.475
40
166.685
2
12.981
45
214.169
4
16.696
50
275.349
6
20.644
55
355.144
8
24.853
60
460.880
10
29.354
70
803.464
12
34.181
80
1541.765
14
39.371
90
3867.556
16
44.966
18
51.011
20
57.558
21
61.037
22
64.663
23
68.444
24
72.388
25
76.503
27
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Entalpia Específica,
kJ/kgda
Tratamiento de Aire y Psicometrias
Temp., °C
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.12 (SI) Propiedades Termodinámicas de Aire Húmedo a Presión
Atmosférica Estándar, 101.325 kPa [2013F, Ch 1, Tbl 2, Abreviada]
01.fm Page 28 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.13 (I-P)
Datos Atmosféricos Estándar para Altitudes a 30.000 pie
[2013F, Ch 1, Tbl 1]
Altitud, pie
–1000
–500
0
500
1.000
2.000
3.000
4.000
5.000
6.000
7.000
8.000
9.000
10.000
15.000
20.000
30.000
Temperatura, °F
62.6
60.8
59.0
57.2
55.4
51.9
48.3
44.7
41.2
37.6
34.0
30.5
26.9
23.4
5.5
–12.3
–47.8
Presión, psia
15.236
14.966
14.696
14.430
14.175
13.664
13.173
12.682
12.230
11.778
11.341
10.914
10.506
10.108
8.296
6.758
4.371
Fuente: Adaptado de la NASA(1976)
Tabla 1.13 (SI)
Datos Atmosféricos Estándar para Altitudes a 10.000 m
[2013F, Ch 1, Tbl 1]
Temperatura, °C
18.2
15.0
11.8
8.5
5.2
2.0
–1.2
–4.5
–11.0
–17.5
–24.0
–30.5
–37.0
–43.5
–50
Presión, kPa
107.478
101.325
95.461
89.875
84.556
79.495
74.682
70.108
61.640
54.020
47.181
41.061
35.600
30.742
26.436
Fuente: Adaptado de la NASA(1976)
A nivel del mar, la temperatura estándar es 15°C; la presión barométrica estándar es
101.325 kPa. La temperatura se asume para disminuir linealmente con el aumento de altitud en
toda la tropósfera (atmósfera baja) y ser constante en las partes bajas de la estratósfera. La atmósfera baja se supone consiste de aire seco que se comporta como un gas perfecto. La gravedad también es asumida constante en el valor estándar, 9.806 65 m/s2.
Los valores en la tabla pueden calcularse de la ecuación:
–5
p = 101.325  1 – 2.25577  10 Z 
5.2559
28
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
(SI)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Altitud, m
–500
0
500
1000
1500
2000
2500
3000
4000
5000
6000
7000
8000
9000
10000
01.fm Page 29 Thursday, March 3, 2016 12:25 PM
a
b
7000 granos = 1 lb
Comparado a 70°Fsaturado
*NUMEROS, 1985, Altadena, CA, por Bill Holladay y Cy Otterholm
Difusión de Aire Espacio
Sistemas de distribución de aire, como ventilación por desplazamiento térmico (TDV) y distribución de aire bajo el piso (UFAD), que entregan aire en el modo de enfriamiento a o cerca del nivel del
piso y retornan aire a o cerca del nivel del techo producen cantidades variables de estratificación del
aire ambiente. Para suministro de nivel de suelo, plumas térmicas que se desarrollan sobre las fuentes
de calor juegan un papel muy importante en el impulso de movimiento de aire del piso al techo. La cantidad de estratificación en el ambiente es determinada principalmente por el balance entre la corriente
de aire total del ambiente y la carga de calor. En la práctica, la temperatura actual y el perfil de concentración depende de los efectos combinados de varios factores, pero es impulsado en gran medida por
las características del suministro de corrinte de aire al ambiente y la configuración de la carga de calor.
29
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Los métodos de difusión de aire de la habitación pueden ser clasificados como uno de los
siguientes:
• Sistemas mixtos producen poco o ninguna estratificación térmica de aire dentro del espacio. Distribución de aire aéreo es un ejemplo de este tipo de sistema.
• Sistemas totalmente estratificados producen poco o ninguna mezcla de aire dentro del
espacio ocupado.
• Sistemas parcialmente mixtos proporcionan alguna mezcla dentro del espacio ocupado
y/o espacio de proceso mientras crea condiciones estratificadas en el volumen de arriba.
La mayoría de distribución de aire bajo piso y diseños de acondicionador de ambiente/trabajo son ejemplos de este tipo de sistema.
• Sistemas de acondicionamiento ambiente/trabajo se centran solamente en acondicionar una cierta porción del espacio para confort térmico y/o control de procesos. Ejemplos
de sistemas de ambiente/trabajo son salidas de escritorio personalmente controlados
(algunas veces referido como sistemas de ventilación personal).
Tratamiento de Aire y Psicometrias
Relaciones de Aire y Humedad*
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 1.14 (I-P)
ASHRAE ha adoptado libras de humedad por libras de aire seco como nomenclatura
normalizada. Las relaciones de otras unidades están expresadas abajo a diversas
temperaturas a punto de condensación.
Porcentaje
Granos/lb
Equivale Pt. de
Lb H2O/lb
Partes por Millón
Aire Seco
Humedad %b
Aire Secoa
Condens. °F
–100
0.000001
1
0.0007
—
–80
0.000005
5
0.0035
—
–60
0.000002
21
0.148
0.13
–40
0.000008
79
0.555
0.5
–20
0.00026
263
1.84
1.7
–10
0.00046
461
3.22
2.9
0
0.0008
787
5.51
5.0
10
0.0013
1315
9.20
8.3
20
0.0022
2152
15.1
13.6
30
0.0032
3154
24.2
21.8
40
0.0052
5213
36.5
33.0
50
0.0077
7658
53.6
48.4
60
0.0111
11.080
77.6
70.2
70
0.0158
15.820
110.7
100.0
80
0.0223
22.330
156.3
—
90
0.0312
31.180
218.3
—
100
0.0432
43.190
302.3
—
01.fm Page 30 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
30
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.6 Clasificación de Métodos de Difusión de Aire [2013F, Ch 20, Fig 1]
01.fm Page 31 Thursday, March 3, 2016 12:25 PM
El suministro de aire a ambientes a través de varios tipos de salidas puede ser distribuido por
chorros de aire turbulentos (sistemas mixtos y parcialmente mixtos) o en una velocidad baja, de
manera unidireccional (sistemas estratificados).
Si un chorro de aire no es obstruido o afectado por paredes, techos u otras superficies, es considerado un chorro libre. Cuando el área de salida es pequeña comparada a las dimensiones del
espacio normal al chorro, el chorro puede ser considerado libre siempre que
Velocidades de la Línea de Centro en Zonas 1 y 2. En la zona 1, la relación Vx/Vo es constante y oscila entre 1.0 y 1.2 igual a la relación de la velocidad del centro del chorro en el
comienzo de la expansión a la velocidad promedio. La relación Vx/Vo varía de aproximadamente
1.0 para boquillas de entrada redondeadas a aproximadamente 1.2 para descargas de tuberías rectas; esto tiene valores mucho más altos para salidas de descarga divergentes.
Evidencias experimentales indican que, en la zona 2,
V
------x- =
Vo
donde
=
Vx
Vo
=
Vc
Cd
Rfa
Ho
Kg
=
=
=
=
=
X

KcHo
-------------X
velocidad de línea central a distancia X de salida, fpm (m/s)
Vc/Cd/Rfa = velocidad inicial promedio en la descarga del conducto sin límites o a
través de la corriente contratada en la vena contracta del orificio o salida de múltiple apertura, fpm (m/s)
velocidad nominal de descarga basado en el área del núcleo, fpm (m/s)
coeficiente de descarga (usualmente entre 0.65 y 0.90)
relación de área libre a área (núcleo) bruta
ancho de chorro en la salida o en la vena contracta, pie (m)
constante de velocidad de línea central, dependiendo del tipo de salida y patrón de
descarga (ver Tabla 1.14)
(1/Kc/Ho)1/2 = distancia de la salida a medición de la velocidad de línea central Vx,
pie (m)
31
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
X  1.5 A R
donde
X
=
distancia de la cara de la salida, pie (m)
=
área sección transversal de espacio confinado normal a chorro, pie2 (m2)
AR
Las características del chorro de aire en un ambiente pueden estar influenciadas por flujos
inversos creados por el mismo chorro de arrastre de aire ambiente. Si el suministro de la temperatura de aire es igual a la temperatura del aire de ambiente, el chorro de aire es llamado chorro
isotérmico. Un chorro con una temperatura inicial diferente de la temperatura del aire de ambiente
es llamado chorro no isotérmico. El diferencial de temperatura de aire entre el suministrado y aire
de ambiente de la habitación genera fuerzas térmicas (flotabilidad) en chorros, afectando (1) la
trayectoria, (2) la ubicación en la que se une y separa del techo/piso, y (3) lanzar. El significado de
estos efectos depende en la relación entre la flotabilidad térmica del aire y el impulso del chorro.
Zonas de Expansión del Chorro. La longitud total de un chorro de aire, en términos de
velocidad máxima o línea central y diferencial de temperatura en la sección transversal puede
dividirse en cuatro zonas:
• Zona 1 es una zona de núcleo corto que se extiende de la cara de salida, en la cual la velocidad máxima y temperatura de la corriente de aire permanece prácticamente sin cambio.
• Zona 2 es una zona de transición, con su longitud determinado por el tipo de salida, relación de aspecto de la salida, turbulencia de corriente de aire inicial, etc.
• Zona 3 es de gran importancia de ingeniería porque, en la mayoría de los casos, el chorro
entra al área ocupada en esta zona. El flujo turbulento está totalmente establecido y será de 25
a 100 diámetros largo equivalente a la salida de aire (ej. ancho de ranura de difusores de aire).
• Zona 4 es una zona de degradación del chorro, donde la velocidad de aire máxima y temperatura decrecen rápidamente. La distancia a esta zona y su longitud depende en las
velocidades y características de turbulencia del aire del ambiente. En pocos diámetros o
anchos, la velocidad del diámetro llega a ser menos de 50 fpm (0.25 m/s).
Tratamiento de Aire y Psicometrias
Fundamentos de Chorros de Aire
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Principios de Comportamiento de Chorro
Tabla 1.15 Valores Recomendados para Constante Kc de Velocidad de Línea
Central para Puntos de Venta de Suministro Comercial para Sistemas Completos y
Parcialmente Mezclados, Excepto UFAD [2013F, Ch 20, Tbl 1]
Tipo de Salida
Rejas de pared lateral altas
Lineal de pared lateral alta
Pared lateral baja
Tablero de Base
Reja de piso
Techo
Ranura lineal de techo
Patrón de Descarga
Ao
Kc
Defleccióna 0°
Libre
5.7
Deflección ancho
Libre
4.2
Núcleo menor de 4 pulg. (100 mm)
altob
Libre
4.4
Núcleo más de 4 pulg. (100 mm) alto
Libre
5.0
Arriba y en la pared, no se propague
Libre
4.5
Libre
3.0
Amplia propagación
Arriba y en la pared, no se propague
Núcleo
4.0
Amplia propagación
Núcleo
2.0
No propagarb
Libre
4.7
Amplia propagación
Libre
1.6
Horizontalc 360°
Cuello
1.1
Cuatro vías, poco difundido
Cuello
3.8
Una vía, horizontal a lo largo de techob
Libre
5.5
aÁrea libre es aproximadamente el 80% del área del núcleo.
bÁrea libre es aproximadamente el 50% del área del núcleo.
c Área
libre del cono es más
grande que el área del ducto.
Velocidad de la Línea Central en la Zona 3. En la zona 3, las velocidades máximas o línea
central de chorros isotérmicos axial y radial pueden determinarse exactamente de la siguiente
ecuación:
donde
Kc
=
constante de velocidad de la línea central
Ao
=
área libre, área de núcleo o área de cuello como se muestra en la Tabla 1.14
(obtenida de fabricante de salida), pie2 (m2)
Ac
=
área bruta medida (núcleo) de salida, pie2 (m2)
Qo
=
descarga de salida, cfm
Debido a que Ao es igual al área efectiva de la corriente, el área de flujo para registros comerciales y difusores, de acuerdo a la Norma 70 de ASHRAE, puede utilizarse en la ecuación de
arriba con el valor apropiado de Kc.
Tiro. La ecuación previa puede ser transformada para determinar el tiro X de una salida si el
volumen de descarga y la velocidad de la línea de centro son conocidas:
K c Qo
X = ----------------V x Ao
32
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
K c V o Ao
K c Qo
V x = ------------------------= --------------X
X Ao
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tratamiento de Aire y Psicometrias
01.fm Page 32 Thursday, March 3, 2016 12:25 PM
01.fm Page 33 Thursday, March 3, 2016 12:25 PM
Xfree = Xattached × 0.707
Chorros libres circulares generalmente tienen tiros más largos comparados a chorros no circulares.
Chorros de difusores de techo inicialmente tienden a adherirse a la superficie del techo,
debido a la fuerza ejercida por el efecto Coanda. Sin embargo, chorros de aire frio se desprenderán
del techo si las fuerzas de flotabilidad de la corriente de aire son mayores que la inercia de la corriente de aire que se mueve.
Figura 1.7 (SI)
Tabla para Determinar las Velocidades de la Línea de Centro de Chorros Axiales y
Radiales [2013F, Ch 20, Fig 3]
33
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.7 (I-P) Tabla para Determinar las Velocidades de la Línea de Centro de Chorros Axiales y
Radiales [2013F, Ch 20, Fig 3]
Tratamiento de Aire y Psicometrias
Los datos de tiro de la mayoría de los fabricantes obtenidos de acuerdo con la Norma 70 de
ASHRAE asumen que la descarga está adherida a la superficie. Un chorro adjunto induce el aire a
lo largo del lado expuesto del chorro, mientras que un chorro libre puede inducir aire en todas las
superficies. Debido a que una tasa de inducción de chorro libre es mayor comparado a aquella de
un chorro adjunto, la distancia del tiro del chorro adjunto será más corta. Para calcular la distancia
de tiro X para un chorro libre no circular de los datos de catálogo para un chorro adjunto, la siguiente estimación puede ser utilizada
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Comparación de Chorro Libre a Chorro Adjunto
01.fm Page 34 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
34
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.8 (I-P) Patrones de Corriente de Aire de Difusores Diferentes
01.fm Page 35 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
35
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Patrones de Corriente de Aire de Difusores Diferentes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 1.8 (SI)
01.fm Page 36 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Distribución de Aire Mezclado
En sistemas de aire mezclado, chorros de suministro de alta velocidad de salidas de aire mantienen la comodidad mezclando aire de la habitación con aire de suministro. Esta mezcla de aire,
transferencia de calor y reducción de velocidad resultante debe ocurrir fuera de la zona ocupada.
La comodidad del ocupante es mantenida no directamente por movimiento de aire de las salidas,
sino del movimiento de aire secundario de la mezcla en la zona no ocupada. La comodidad es
maximizada cuando la distribución de temperatura uniforme y velocidades de aire de la habitación
de menos de 50 fpm (0.25 m/s) son mantenidos en la zona ocupada.
Manteniendo velocidades menores de 50 fpm (0.25 m/s) en la zona ocupada es a menudo pasado por alto por los diseñadores, pero es crítico para el mantenimiento del confort. La selección de
salidas, ubicación, volumen de aire de suministro, velocidad de descarga y diferencial de temperatura de aire determina el movimiento de aire resultante en la zona ocupada.
Principios de Operación
Sistemas mezclados generalmente proporcionan confort por arrastre de aire de la habitación
en los chorros de descarga situados afuera de las zonas ocupadas, mezclando aire de la habitación
y de suministro. Idealmente, estos sistemas generan movimiento de aire de baja velocidad (menos
de 50 fpm [0.25 m/s]) a través de la zona ocupada para proveer temperatura uniforme en gradientes y velocidades. La selección apropiada de una salida de aire es crítica para distribución de aire
apropiado: la selección no apropiada puede resultar en estancamiento de aire de la habitación, gradientes de temperatura inaceptables y velocidades inaceptables en la zona ocupada que pueden
llevar a malestar del ocupante.
La ubicación de un chorro de descarga en relación con superficies circundantes es importante.
Chorros de descarga unidos a superficies paralelas, que dan velocidad y proximidad suficiente.
Cuando un chorro está unid, el tiro se aumenta alrededor del 40% sobre un chorro descargad en un
área abierta. Esta diferencia es importante cuando se selecciona una salida de aire. Para discusiones detalladas del efecto de la superficie en chorros de descarga, ver Capítulo 20 del Manual—
Fundamentos de ASHRAE 2013.
Sistemas de aire mezclados típicamente utilizan salidas de techo o pared lateral descargando
el aire horizontalmente, o salidas de piso o montado en el umbral descargando el aire verticalmente. Ellos son los métodos más comunes de distribución de aire en Norte América.
Salidas de techo típicamente utilizan el efecto de superficie para transportar el aire de suministro en la zona no ocupada. Los proyectos de aire de suministro a través del techo y con suficiente
velocidad, pueden continuar hacia debajo de las superficies de la pared y a través de los pisos. En
esta aplicación, el aire de suministro debe permanecer fuera de la zona ocupada hasta que está
adecuadamente mezclado y temperado con el aire de la habitación.
Figura 1.9 Aire Suministrado al Techo Induce el Aire de la Habitación en Chorro de Suministro
[2011A, Ch 57, Fig 2]
36
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Refrigeración de Descarga Horizontal con Salidas de Techo
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Diseño del Sistema
01.fm Page 37 Thursday, March 3, 2016 12:25 PM
Salidas proyectadas verticalmente son típicamente seleccionadas para aplicaciones de techos
altos que requieren forzar el aire de suministro abajo a la zona ocupada. Es importante mantener la
velocidad del aire de suministro refrigerado bajo 50 fpm (0.25 m/s) en la zona ocupada. Para la
calefacción, el aire de suministro debe llegar al piso.
Hay salidas específicamente diseñadas para proyección vertical y es importante revisar las
notas de datos de rendimiento del fabricante para entender cómo aplicar los datos del catálogo.
Tiros para refrigeración y calefacción difieren y también varían dependiendo en la diferencia entre
suministro y temperaturas de aire de la habitación.
Enfriamiento con Salidas de Pared Lateral
Enfriamiento con Salidas de Aire Montadas en el Piso
Aunque no son típicamente seleccionadas para edificios no residenciales, salidas montadas en
el piso pueden ser usados para aplicaciones de enfriamiento de sistemas mixtos. En esta configuración, el aire de la habitación de la zona ocupada es inducido en el aire de suministro, proporcionando una mezcla. Cuando se enfría, el dispositivo de ser seleccionado para descargar
verticalmente a lo largo de ventanas, paredes y otras superficies verticales. Aplicaciones no residenciales típicas incluyen vestíbulos, corredores largos, casas de culto.
Es importante seleccionar un dispositivo que está especialmente diseñado para aplicaciones
de piso. Debe ser capaz de soportar ambos la dinámica requerida y las cargas estructurales estáticas (ej. la gente caminando sobre ellos, carros cargados rodando a través de ellos). También,
muchos fabricantes ofrecen dispositivos diseñados para reducir la posibilidad de objetos cayendo
37
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Las salidas de pared lateral son usualmente seleccionadas cuando el acceso a la cámara de
techo es restringido. Las salidas de pared lateral dentro de 1 pie (300 mm) de un techo y se ajustan
para una proyección horizontal o ligeramente hacia arriba, la salida de pared lateral provee un
patrón de descarga que se une al techo y viaja en la zona no ocupada. Este patrón arrastra aire de
la zona ocupada para proporcionar una mezcla.
En algunas aplicaciones, la salida debe ser ubicada 2 a 4 pies (0.5 a 1.25 m) bajo el techo.
Cuando se ajusta para proyección horizontal, la descarga a alguna distancia de la salida puede caer
en la zona ocupada. Algunos dispositivos utilizados para aplicación de pared lateral pueden ser
ajustados para proyectar el patrón de aire para arriba, hacia el techo. Esto permite al aire de descarga que se una al techo, incrementando la distancia del tiro y minimizando la caída. Esta aplicación provee al ocupante confort mediante la inducción de aire de la zona ocupada en el aire de
suministro.
Algunas salidas pueden tener más de 4 píe (1.25 m) bajo el techo (ej. aplicaciones de techo
alto, la salida deben estar situada junto a la zona ocupada para minimizar el volumen del espacio
acondicionado). La mayoría de los dispositivos utilizados para aplicaciones de pared lateral
pueden ser ajustados para proyectar el patrón de aire para arriba o hacia abajo, lo cual permite la
distancia de tiro del dispositivo ser ajustado para maximizar el rendimiento.
Al seleccionar las salidas de la pared lateral, es importante entender los datos del fabricante.
La mayoría de los fabricantes ofrecen datos para salidas probadas con efecto de superficie, por lo
que sólo se aplican si el dispositivo es ajustado para dirigir el aire de suministro hacia el techo.
Cuando el dispositivo es 4 pie (1.25 m) o más bajo un techo, o el aire de suministro es dirigido
horizontalmente o hacia abajo, la distancia de tiro actual del dispositivo es típicamente más corto.
Muchas salidas de pared lateral pueden ser ajustadas para cambiar el esparcimiento de aire de
suministro, lo cual cambia significativamente la distancia del tiro. Los fabricantes usualmente
publican las distancias de tiro basadas en ángulos de esparcimiento específico.
Tratamiento de Aire y Psicometrias
Refrigeración o Calefacción de Descarga Vertical con Salidas de Techo
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Salidas aéreas pueden también ser instaladas en conductos expuestos, en cuyo caso el efecto
de la superficie no aplica. Típicamente, si la salida está montada 1 pie (300 mm) o más bajo la
superficie de un techo, el aire de descarga no se juntará a la superficie. El aire de suministro no
adjunto tiene un corto tiro y puede proyectar hacia abajo, resultando en altas velocidades de aire
en la zona ocupada. Algunas salidas son diseñadas para uso en aplicaciones de conductos expuestos. Los datos de rendimiento de salida típicos presentados por los fabricantes son para salidas con
efecto de superficie: consultar a los fabricantes para información sobre aplicaciones de conductos
expuestos.
en el dispositivo. Se recomienda encarecidamente que las obstrucciones no estén localizadas sobre
estos en las terminales aéreas del piso, para evitar restringir sus chorros de aire.
Las rejillas montadas en el piso generalmente tienen ambos segmentos de funcionamiento y
no funcionamiento. Cuando se seleccionen salidas de aire para montaje en el piso, es importante
notar que la distancia de tiro y sonido generado depende en la longitud de la sección activa. Los
datos de catálogos de la mayoría de los fabricantes incluyen factores de corrección para efectos de
longitudes en ambos tiro y sonido. Estas correcciones pueden ser significativas y deben ser evaluadas. Entender los datos de rendimiento del fabricante y notas correspondientes es imperativo.
Enfriamiento con Salidas de Aire Montadas en el Umbral
Salidas de aire montadas en el umbral son comúnmente utilizadas en aplicaciones que
incluyen unidades de ventilación y unidades de serpentín y ventilador. La salida debe ser seleccionada para descargar verticalmente a lo largo de ventanas, paredes u otras superficies verticales y
proyecto de aire de suministro sobre la zona ocupada.
Como con rejillas de piso montadas, cuando se seleccione y ubique las rejillas del umbral,
considere seleccionar dispositivos diseñados para reducir la molestia de objetos que caen dentro
de ellos. Es también recomendado que los umbrales sean diseñados para prevenirlos de ser utilizados como estanterías.
Calefacción y Refrigeración con Salidas de Techos Montados Perimetrales
Cuando salidas de aire son usadas en el perímetro con proyección vertical para calefacción y/
o refrigeración, ellos deben ser ubicados cerca de la superficie perimetral, y seleccionado de
manera que el tiro isotérmico publicado 150 fpm (0.75 m/s) se extienda por lo menos hasta la
mitad de la superficie ó 5 pie (1.5 m) sobre el piso, cualquiera sea más bajo. En esta manera,
durante el calentamiento, el aire tibio se mezcla con la corriente descendente fría en la superficie
del perímetro, para reducir o incluso eliminar corrientes de aire en los espacios ocupados.
Si una salida de techo montado está ubicada lejos de la pared perimetral, en modo de enfriamiento, el aire frio de alta velocidad reduce o supera las corrientes ascendentes térmicas en la
superficie del perímetro. Para lograr esto, la salida debe ser seleccionada para descarga horizontal
hacia la pared. La selección de salida debe ser tal que el tiro isotérmico a la velocidad terminal de
150 fpm (0.75 m/s) deberá incluir la distancia de la salida a la superficie perimetral. Para calefacción, la temperatura de aire de suministro no debe exceder 15°F (8.5°C) por encima de la temperatura de aire de la habitación.
Un sistema totalmente mezclado crea condiciones térmicas homogéneas a través del espacio.
Como tal, las gradientes térmicas no se debe esperar que existan en zona ocupada. La selección
inadecuada, tamaño o colocación pueden evitar la mezcla completa y puede resultar en áreas
estancadas, o tener aire de alta velocidad que entre en la zona ocupada.
Los requisitos de flujo de aire de suministro para satisfacer pérdidas o ganancias de calor sensible en el espacio son inversamente proporcionales a la diferencia de temperatura entre aire de
suministro y retorno. La siguiente ecuación puede ser usada para calcular los requisitos de flujo de
aire del espacio (en condiciones normales):
qs
Q = ----------------------------1.08  t r – t s 
(I-P)
qs
Q = -------------------------1.2  t r – t s 
(SI)
donde
Q
=
tasa de flujo de aire requerido para satisfacer la carga sensible, cfm (L/s)
=
ganancia neta de calor sensible en el espacio, Btu/h (W)
qs
=
temperatura de aire de escape o retorno, °F (°C)
tr
=
temperatura de aire de suministro, °F (°C)
ts
Para sistemas con mezcla completa con altura de techo convencional, el retorno (o escape) y
temperaturas de aire de habitación son las mismas; por ejemplo, una habitación con una temperatura de punto de referencia de 75°F (24°C) tiene en promedio, una temperatura de aire de retorno
o escape de 75°F (24°C).
38
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Gradientes de Temperatura del Espacio y Tasas de Flujo de Aire
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tratamiento de Aire y Psicometrias
01.fm Page 38 Thursday, March 3, 2016 12:25 PM
01.fm Page 39 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Figura 1.10 (I-P) Porcentaje de Ocupantes que Objetan Corrientes de Aire en Habitaciones con
Aire Acondicionado
Porcentaje de Ocupantes que Objetan Corrientes de Aire en Habitaciones con
Aire Acondicionado
El objeto de difusión de aire en sistemas de caliente-calentador de aire, ventilación y aire
acondicionado es crear la combinación propia de temperatura, humedad y movimiento de aire en
la zona ocupada de la habitación acondicionada desde el piso a 6 pies (2 m) sobre el nivel del
piso.
La incomodidad puede surgir debido a cualquiera de los siguientes: movimiento de aire (corriente de aire), variaciones de temperatura del aire de la habitación excesivas (horizontal, vertical
o ambos), falta de entrega o distribución de aire de acuerdo a los requisitos de carga en ubicaciones diferentes, demasiado rápida fluctuación de la temperatura de la habitación.
Índice de Rendimiento de Difusión de Aire (ADPI)
El índice de rendimiento de difusión de Aire (ADPI) es el porcentaje de los lugares
donde se toman las medidas que cumplen estas especificaciones para temperatura de proyecto
efectiva y velocidad del aire. Si el ADPI es máximo (acercándose al 100%), las condiciones
más deseables se han logrado. El ADPI debe ser usado sólo para modo de enfriamiento en
ocupaciones sedentarias. Donde el aire no choca una pared pero colisiona con el aire de un
difusor vecino, L es la mitad de distancia entre los difusores más la distancia del aire cae a la
zona ocupada.
39
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 1.10 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Normas para Difusión de Aire Satisfactorio
Tabla 1.16 Longitud de Habitación Característica para Varios Difusores
Tipo de Difusor
Rejilla de pared lateral alta
Techo circular patrón difusor
Reja de umbral
Difusor de techo
Difusores de luz
Difusores de techo de patrón de flujo
cruzado
Longitud Característica L
Distancia a pared perpendicular a chorro
Distancia a la pared más cercana o chorro de aire de
intersección
Longitud de habitación en dirección del flujo del chorro
Distancia a pared o plano medio entre salidas
Distancia a plano medio entre salidas más distancia del
techo hasta arriba de la zona ocupada
Distancia a la pared o plano medio entre salidas
Tabla 1.17 Guía de Selección de Índice de Rendimiento de Difusión de Aire
Dispositivo
Terminal
Rejilla de lado de
pared alta
X50 (0.25)/L para
Carga de
Máximo Para ADPI Márgen de
Máximo
Habitación,
ADPI Mayor que X50 (0.25)/L
ADPI
Btu/h·pie2 (W/m2)
80 (250)
1.8
68
—
—
60 (190)
1.8
72
70
1.5 to 2.2
40 (125)
1.6
78
70
1.2 to 2.3
20 (65)
1.5
85
80
1.0 to 1.9
<10 (30)
1.4
90
80
0.7 to 2.1
0.8
0.8
0.8
0.8
0.8
76
83
88
93
99
70
80
80
80
80
0.7 to 1.3
0.7 to 1.2
0.5 to 1.5
0.4 to 1.7
0.4 to 1.7
Rejilla umbral
aletas planas
80 (250)
60 (190)
40 (125)
20 (65)
1.7
1.7
1.3
0.9
61
72
86
95
60
70
80
90
1.5 to 1.7
1.4 to 1.7
1.2 to 1.8
0.8 to 1.3
80 (250)
60 (190)
40 (125)
20 (65)
80 (250)
60 (190)
40 (125)
20 (65)
0.7
0.7
0.7
0.7
0.3
0.3
0.3
0.3
94
94
94
94
85
88
91
92
90
80
—
—
80
80
80
80
0.6 to 1.5
0.6 to 1.7
—
—
0.3 to 0.7
0.3 to 0.8
0.3 to 1.1
0.3 to 1.5
60 (190)
40 (125)
20 (65)
2.5
1
1
86
92
95
80
90
90
<3.8
<3.0
<4.5
11 to 50 (35 to 160)
11 to 50 (35 to 160)
2
2
96
96
90
80
1.4 to 2.7
1.0 to 3.4
Rejilla umbral
aletas de dispersión
Difusores de techo
(para T100 (0.5)/L)
Difusores de
canaleta de luz
Difusores de patron
de flujo cruzado
40
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Difusores de techo
circular
80 (250)
60 (190)
40 (125)
20 (65)
<10 (30)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tratamiento de Aire y Psicometrias
01.fm Page 40 Thursday, March 3, 2016 12:25 PM
01.fm Page 41 Thursday, March 3, 2016 12:25 PM
Principios de Operación
Figura 1.11 Características del Sistema de Ventilación por Desplazamiento [2011A, Ch 57, Fig. 3]
41
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Sistemas de ventilación por desplazamiento térmico (TDV) (ver Figura 1.11) utilizan muy poca
velocidades de descarga, típicamente 50 a 70 fpm (0.25 a 0.35 m/s), para enviar aire de suministro
frio al espacio. La temperatura de descarga del aire de suministro está generalmente sobre 60°F
(16°C), aunque temperaturas más bajas pueden ser utilizadas en aplicaciones industriales, instalaciones de ejercicios o deportivas y áreas de transeúntes. El aire frio es negativamente boyante comparado al aire de ambiente y caída al piso después de la descarga. Después se propaga a través del
nivel más bajo del espacio.
Como fuentes de calor por convección (ver la Figura 1.11) en el espacio transfieren calor al aire
más frio alrededor de ellos, corrientes por convección naturales se forman y suben alrededor del
límite de transferencia de calor. Sin movimiento significante de aire de habitación, estas corrientes se
elevan para formar una columna de calor por convección alrededor y sobre la fuente de calor. Como
la columna se levanta, esta se expande por arrastre de aire circundante. Su crecimiento y subida son
proporcionales al tamaño de la fuente de calor e intensidad y temperatura del aire de ambiente sobre
éste. El aire de ambiente bajo y alrededor de la fuente de calor llena el vacío creado por la columna
ascendente de calor. Si la fuente de calor está cerca del piso (ej. un ocupante) la columna arrastra
frio, aire acondicionado del nivel del piso, el cual es conducido al nivel de respiración, y sirve como
la fuente de aire inhalado. El aire exhalado sube con la columna de escape de calor, porque es más
caliente y más húmedo que el aire de ambiente. Calor por convección de fuentes ubicadas sobre la
zona ocupada tiene poco efecto en temperatura de aire d zona ocupada.
A cierta altura, donde la temperatura de la columna iguala la temperatura de ambiente, la
columna se desintegra y derrama horizontalmente. Dos zonas distintas son entonces formas en la
habitación: una zona inferior ocupada con poco o nada de flujo de recirculación (cerca del flujo de
desplazamiento) y una zona superior con flujo de recirculación. El límite entre estas dos zonas es
llamado zona de cambio. La altura de la zona de cambio es calculada como la altura sobre el piso
donde la cantidad total de aire llevada en columnas por convección sobre las fuentes de calor
iguala el flujo de aire de suministro distribuido a través de difusores de desplazamiento. Representaciones actuales y simplificadas del gradiente de temperatura en el espacio están mostradas en
la Figura 1.12.
Tratamiento de Aire y Psicometrias
Los sistemas que descargan aire fresco en la pared lateral baja o ubicaciones del piso con muy
poco arrastre del aire de habitación (y mezclando así con) crean (vertical) estratificaciones térmicas a través del espacio. Estos sistemas de ventilación por desplazamiento han sido populares en
Europa del norte durante algún tiempo. Salidas del suelo basadas en aplicaciones bajo suelo
pueden también ser utilizadas para proveer distribución de aire completamente estratificada.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Distribución de Aire Completamente Estratificada
Figura 1.12 Perfil de Temperatura de Ventilación por Desplazamiento [2011A, Ch 57, Fig 4]
Consideraciones sobre la Aplicación
La ventilación por desplazamiento es un único método de enfriamiento de la distribución de
aire de la habitación. Para calefacción, un sistema separado es generalmente recomendado. Ventilación por desplazamiento puede utilizarse con éxito en combinación con radiadores y convectores instalados en las paredes exteriores para compensar las pérdidas de calor de los espacios.
Paneles de calefacción radiantes y pisos calientes también pueden ser utilizados con ventilación
por desplazamiento. Para mantener ventilación por desplazamiento, las salidas deben suministrar
aire de ventilación alrededor de 4°F (2) más bajo que la temperatura de habitación deseada.
Los sistemas de ventilación por desplazamiento térmico pueden ser cualquiera, volumen de
aire variable o constante. Un termostato en una ubicación representante en el espacio o pleno de
retorno debe de determinar el volumen de aire suministrado o temperatura. Si los requisitos promediados en el tiempo de la Norma 62.1-2004 de ASHRAE son satisfechos, control de corriente
de aire de encendido/apagado intermitente puede ser utilizado.
Evite utilizar desplazamiento térmico y sistemas de aire mezclado en el mismo espacio, porque
mezclando destruye la estratificación natural que acciona el sistema de ventilación por desplazamiento térmico. Sistemas por desplazamiento térmico pueden ser complementados por sistemas
42
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Características de Salida
Las salidas por desplazamiento son diseñadas para velocidades de cara promedio entre 50 y
70 fpm (0.25 a 0.35 m/s) y están típicamente en una pared lateral baja o ubicada en el piso. Entradas de aire de escape o retorno deben estar siempre ubicadas sobre la zona ocupada para aplicaciones de confort térmico humano.
Las salidas por desplazamiento están disponibles en un número de configuraciones y
tamaños. Algunos modelos están diseñados para encajar en las esquinas o a lo largo de paredes
laterales, o sostenerse libremente como columnas. Es importante considerar el grado de compensación de flujo que las salidas logran, porque el uso de la superficie de salida entera para descarga
de aire es de suma importancia para minimizar zonas claras y mantener temperaturas aceptables a
los niveles más bajos del espacio.
Ocupantes fijos no deben ser sometidos a velocidades de descarga que excedan 40 fpm
(0.2 m/s) porque el aire en el nivel del tobillo dentro de este sobre de velocidad tiende a ser bastante fresco. Como tal, la mayoría de los fabricantes de salidas define una zona clara en el cual la
ubicación de fijo, ocupantes de baja actividad es fuertemente desaconsejada, pero ocupación transitoria, como en corredores o pasillos, es posible. Ocupantes con niveles de alta actividad pueden
también encontrar la zona clara aceptable.
A diferencia de sistemas mixtos, salidas en sistemas de desplazamiento térmico descarga aire
a velocidades muy bajas, resultando en muy poca mezcla. Como tal, el diseño de estos sistemas
principalmente involucra determinar una tasa de flujo de aire de suministro para controlar los gradientes térmicos en el espacio de conformidad con las directrices de confort de ASHRAE. La
Norma 55 de ASHRAE recomienda que la diferencia de temperatura vertical entre los niveles de
tobillo y cabeza de los ocupantes de espacio sea limitada a no más de 5.4°F (3 k) para mantener un
alto gado (>95%) de la satisfacción del ocupante.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tratamiento de Aire y Psicometrias
01.fm Page 42 Thursday, March 3, 2016 12:25 PM
01.fm Page 43 Thursday, March 3, 2016 12:25 PM
Las características de sistemas mezclados parcialmente caen entre un sistema mezclado totalmente y un sistema totalmente estratificado. Esto incluye ambos una zona de aire mezclado a alta
velocidad y una zona estratificada a alta velocidad donde el movimiento de aire de a habitación es
causado por fuerzas térmicas. Por ejemplo, salidas basadas en el piso, cuando se opera en el modo
de enfriamiento con velocidades de descarga relativamente altas (>150 fpm [0.75 m/s]), crean la
mezcla, afectando de esta manera la cantidad de estratificación en las porciones bajas de la
habitación. En las porciones superiores de la habitación, lejos de la influencia de salidas de piso,
el aire de la habitación a menudo permanece térmicamente estratificado de la misma manera como
sistemas de ventilación por desplazamiento.
Principios de Operación
El aire de suministro es descargado, generalmente verticalmente, a velocidades relativamente
altas y arrastran aire a la habitación de manera similar a las salidas utilizadas en sistemas de aire
mezclado. Este arrastre, como mostrado en la Figura 1.13 reduce la temperatura y diferenciales de
velocidad entre el suministro y el aire ambiente de la habitación. Esta descarga resulta en una
columna vertical que se levanta hasta que su velocidad es reducida a alrededor de 50 fpm (0.25 m/s).
En este punto, la energía cinética es insuficiente para arrastrar mucho más aire a la habitación, así
que las mezclas se paran. Debido a que aire en la columna todavía está fría que el aire circundante, el
aire de suministro se expande horizontalmente a través del espacio, donde este es arrastrado por
columnas térmicas elevadas generadas por fuentes de calor cercanas.
Investigación y experiencia han mostrado que la cantidad de estratificación de aire de
habitación varía dependiendo en el diseño, puesta en marcha y operación. El control de estratificación incluye las siguientes consideraciones:
• Reduciendo la corriente de aire y mezcla en la zona ocupada, la energía del ventilador
puede ser reducida y la estratificación puede ser incrementada, aproximándose a un objetivo razonable en 3°F a 4°F (1.5 a 2.5 K) diferencia de temperatura de cabeza a la altura
del tobillo, lo que satisface la Norma 55-2010 de ASHRAE.
• Incrementando la corriente de aire y mezcla en la zona ocupada, la estratificación excesiva puede ser omitida, mejorando de este modo el confort térmico.
Figura 1.13 Sistema de Distribución de Aire Bajo el Piso (UFAD) en Aplicación Parcialmente
Estratificada [2011A. Ch 57, Fig 6]
43
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
La Figura 1.13 muestra un ejemplo de la distribución de aire en la habitación resultante en el
cual el aire de la habitación es mezclado en la zona mixta más baja, la cual está delimitada por el
piso y la elevación (altura del tiro) en el cual 50 fpm (0.25 m/s) velocidad terminal se produce. En
esta elevación, la estratificación empieza a ocurrir y una gradiente de temperatura lineal, similar a la
que se encuentra en los sistemas por desplazamiento térmico, se forma y extiende a través de la zona
estratificada. Como con la ventilación por desplazamiento térmico, columnas de calor por convección de fuentes de calor del espacio arrastra aire acondicionado desde el nivel más bajo (mezclado) a
través de la zona estratificada y a la ubicación de retorno aérea. Una tercera zona, referida como la
zona mixta superior, puede existir donde el volumen de las columnas de calor ascendente terminan.
Aunque las velocidades en esta área son bastante bajas, el aire tiende a ser mezclado.
Tratamiento de Aire y Psicometrias
Distribución de Aire Mezclado Parcialmente
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
hidrónicos como pisos refrigerados. Tenga cuidado cuando combine techos refrigerados, vigas o
paneles con sistemas totalmente estratificados, porque las superficies frías en la zona superior del
espacio puede recircular contaminantes estratificados en la zona superior atrás en la zona ocupada.
01.fm Page 44 Thursday, March 3, 2016 12:25 PM
Tratamiento de Aire y Psicometrias
Un tipo de salida es un difusor rotacional con un núcleo de inducción alto, el cual induce
grandes cantidades de aire de la habitación para reducir rápidamente el suministro de velocidad de
aire ambiental y diferenciales de temperatura. El aire de suministro es inyectado a la habitación
como una columna vertical de remolino cerca de la salida. Apropiadamente seleccionada, estas
salidas producen una proyección vertical limitada de la columna de aire de suministro, restringiendo la mezcla a las porciones más bajas del espacio. La mayoría de estas salidas permite a los
ocupantes ajustar el caudal de aire de salida fácilmente. Otras versiones incorporan automáticamente amortiguadores controlados que son reposicionados por una señal desde el termostato espacio y/o sistema de control central.
Otra categoría incluye más rejillas de piso convencional diseñadas para descarga direccional
de flujo de aire suministrado. Estas rejillas pueden ser lineal o modular en diseño, y pueden permitir a los ocupantes ajustar el patrón de aire de descarga reposicionando el núcleo de la salida. La
mayoría de las rejillas de piso incluyen un amortiguador accionado integral, u otros medios, que
automáticamente reduce el volumen de aire en respuesta a los requisitos de acondicionamiento de
la zona.
La inducción de aire a la habitación permite a los difusores de Distribución de Aire Bajo el
Piso (UFAD) entregar confortablemente aire de suministro unos pocos grados más frio que sea
posible con salidas utilizadas para salidas de ventilación de desplazamiento térmico. La observación de zonas clara, o adyacente, arriba o alrededor de los difusores, donde los ocupantes fijos
no deben residir, es recomendado. Los fabricantes de salidas típicamente identifican estas áreas
restringidas en la literatura de su producto.
Para sistemas de desplazamiento térmico, el diseño involucra determinar una tasa de flujo de
aire de suministro que limita los gradientes térmicos en la zona ocupada de acuerdo con las pautas
de la Norma 55 de ASHRAE. La Norma 55 de ASHRAE recomienda que la diferencia de temperatura vertical entre el tobillo y nivel de cabeza de ocupantes del espacio sea limitado a no más
de 5.4°F (3 K) si un alto grado (>95%) de confort de los ocupantes se ha de mantener.
Consideraciones sobre la Aplicación
44
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Algunas consideraciones incluyen lo siguiente:
• Temperaturas de suministro en la cavidad del piso de acceso deben mantenerse a 60°F
(16°C) o por encima, para minimizar el riesgo de condensación y subsecuente crecimiento de moho.
• La mayoría de las salidas de Distribución de Aire Bajo el Piso (UFAD) se pueden ajustar
automáticamente por un termostato espacio u otro sistema de control, o manualmente por
el ocupante. En el último caso, las salidas deben estar ubicadas dentro de la estación de
trabajo que sirven.
• El uso de salidas ajustadas manualmente deben ser restringidas a áreas de oficinas abiertas donde las cargas de enfriamiento no tienden a variar considerable o frecuentemente.
Áreas perimetrales y salas de conferencia requieren control automático de temperaturas
de aire de suministro y/o tasas de flujo porque sus cargas térmicas son altamente transitorias.
• Transferencia de calor a y desde la losa del piso afecta la temperatura de aire de descarga
y será considerado cuando se calcula los requisitos del flujo de aire del espacio. Los plenos del piso deberán estar bien sellados para minimizar la filtración de aire y las paredes
exteriores deben estar bien aisladas y tener buenos retardadores de vapor. Reveses de temperatura de fiesta y noche deben ser eliminadas, o por lo menos reducidas, para minimizar
la condensación del pleno y los problemas de efecto de masa térmica. Con economizadores de lado de aire, utilizando control de entalpia en vez de control de bola seca puede
ayudar a reducir horas de admitir aire de alto contenido de humedad, por tanto también
reducen el potencial para condensación en los plenos del piso.
• Evite utilizar sistemas estratificados y de aire mixto en el mismo espacio, porque mezclando destruyen la estratificación natural que maneja el sistema estratificado.
• La caída de presión estática de retorno debe ser relativamente igual a través de los espacios que son servidos por un pleno de Distribución de Aire Bajo el Piso (UFAD) común.
Esto reduce la posibilidad de presurización desigual en el pleno de Distribución de Aire
Bajo el Piso (UFAD).
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Características de Salida
01.fm Page 45 Thursday, March 3, 2016 12:25 PM
Tabla 1.18
Velocidades de la Cara de Entrada de Retorno Recomendada
[2011A, Ch 57, Tbl 1]
Ubicación de Entrada
Encima de la zona ocupada
En zona ocupada, no cerca de asientos
En zona ocupada, cerca de asientos
Velocidad a través del Área Bruta, fpm (m/s)
>800 (4)
600 a 800 (3 a 4)
400 a 600 (2 a 3)
Persianas de ventanas o paredes
200 a 300 (1 a 1.5)
A través del área rebajada de puertas
200 a 300 (1 a 1.5)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
45
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Tratamiento de Aire y Psicometrias
El éxito de un sistema de distribución de aire mezclado depende principalmente en suministrar la ubicación del difusor. La ubicación de rejilla de retorno es mucho menos crítica que con
salidas. En efecto, la entrada de aire de retorno afecta el movimiento de aire de la habitación solo
inmediatamente alrededor de la rejilla. Las medidas de velocidad cerca a una rejilla de aire de
retorno muestran un descenso rápido en magnitud como el dispositivo de medida es alejado de la
cara de la rejilla. La tabla de abajo muestra velocidades de la rejilla de aire de retorno máximas
recomendadas como una función de la ubicación de la rejilla. Cada espacio cubierto debe tener
entradas de retorno/transferencia de tamaño adecuado de acuerdo a esta tabla.
Para sistemas de distribución de aire estratificado y parcialmente mezclado, hay ubicaciones
ventajosas para entradas de aire de retorno. Por ejemplo, una admisión puede estar ubicada para
retornar el aire más caliente en estaciones frías.
Si la salida es seleccionada para proporcionar tiro adecuado y dirigido lejos de retornos o
evacuaciones, suministro de cortocircuitos normalmente no es un problema. El éxito de esta práctica está confirmado por la disponibilidad y uso de suministro de combinación y difusores de
retorno.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Entradas de Aire de Retorno
02.fm Page 46 Thursday, March 3, 2016 12:27 PM
CONTAMINANTES DE AIRE Y CONTROL
Tabla 2.1 Normas de Calidad de Aire Ambiental Nacional para los Estados Unidos
[2013F, Ch 11, Tbl 12]
Contaminante
Norma
Primaria o
Secundaria
Tiempo
Promedio
Nivel
Detalles
Monóxido de
carbono
Primaria
1h
8h
35 ppm
9 ppm
No podrá superarse más de una vez
por año
Primaria
1h
100 ppm
Percentile 98, promediado más de 3
años
Primaria/
secundaria
1 año
53 ppb
Primaria/
secundaria
8h
Primaria
1h
Contaminantes de Aire y Control
Bióxido de
nitrógeno
Ozono
Dióxido de azufre
Secundaria
3h
24 h
Partícula,
PM2.5ª
Primaria/
Secundaria
Partícula,
PM10b
Primaria/
Secundaria
24 h
Plomo (Pb) en
partículas
Primaria/
Secundaria
3m
1 año
Media anual
Concentración de 8 h máximo diaria
Mayor cuarto anual, promediado
Más de 3 años
Percentile 99 de 1 h de
75 ppb concentración Máxima diaria,
promediado más de 3 años
No podrá superarse más de una vez
500 ´ppb
por año
35 µg/m3 Percentile 98, promediado más de 3
Años Media anual, promediado más
15 µg/m3
de 3 Años
No podrá superarse más de una vez
3
150 µg/m Por año en promedio de más de 3
Años
75 ppb
0.15 µg/m3 No podrá superarse
a PM
2.5 = Partículas por debajo de 2.5 µm diámetro.
b PM
10 = Partículas por debajo de 10 µm diámetro.
Figura 2.1 Distribución de Tamaño de Partícula de Polvo Atmosférico
46
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
ppb = Partes por 10°
Fuente: Normas de Calidad de Aire Ambiental Nacional (NAAQS), Agencia de Protección Ambiental de los Estados
Unidos. Washington, DC, 2012.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
2.
02.fm Page 47 Thursday, March 3, 2016 12:27 PM
Bioaerosoles
Los bioaerosoles, partículas de origen biológico, son de interés en el aire interior debido a su
asociación con alergias y asma y su capacidad para causar la enfermedad.
Virus aéreos y aerosoles bacterianos son generalmente transmitidos por núcleos de gotitas,
promediando cerca de 3 µm en diámetro. Esporas de hongos oscilan entre 2 µm y 5 µm. El cincuenta a setenta por ciento de filtros de eficiencia de manchas de polvo pueden remover más agentes microbianos 1 µm a 2µm en diámetro. El sesenta por ciento de filtros de eficiencia de manchas
de polvo pueden remover 95% o más de 2.5 µm partículas, mientras que el 85% de filtros pueden
remover cerca del 96%.
Instalación de Filtros
Normas de Filtración de Aire de ASHRAE
La Norma 52.1 de ASHRAE (retirada en el 2009) contiene un procedimiento de prueba para
medir el peso de un polvo sintético captados por un filtro (arrestancia). Esto da una norma para
comparar la capacidad de fibras para remover partículas gruesas. La Norma 52.2 de ASHRAE
contiene el procedimiento de prueba para comparar la eficiencia de remoción del filtro por tamaño
de partícula. Para filtros más eficientes, la arrestancia es esencialmente 100% eficiente y su eficiencia en remover partículas pequeñas es probada. La eficacia de detección del polvo de la
Norma 52.1 es reemplazada por la clasificación y pruebas de la Norma 52.2.
47
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
La eficiencia es drásticamente reducida si el aire se fuga a través de marcos mal instalados o
diseñados. Instalar los filtros con el área de la cara en ángulos recto con el flujo de aire siempre
que sea posible. Instalar filtros de alta eficiencia tan cerca como sea posible a la habitación para
minimizar la captación de partículas entre el filtro y la salida. Provea por lo menos 20 pulg.
(500 mm) de acceso al frente o atrás de los filtros, o ambos.
Contaminantes de Aire y Control
Los depuradores de aire electrónico utilizan precipitación electrostática para remover y recoger partículas contaminantes como polvo, humo y polen. Los cables con un potencial de corriente positiva entre 6 y 25 kV DC son suspendidos equidistantes entre placas de conexión a tierra,
creando un campo ionizante para partículas de carga.
La sección de placas colectoras consiste de placas paralelas con un voltaje positivo de 4 a 10 kV
(dc) aplicado a placas alternas. Placas que no están cargadas están a potencial de tierra. Como las
partículas pasan dentro de esta sección, están forzadas a las placas por el campo eléctrico en las cargas que ellas llevan, y por lo tanto son removidas de la corriente de aire y recogidas por las placas.
Los depuradores de aire electrónico suelen operar dese un 120- ó 240- V AC servicio eléctrico
monofásico. El consumo de energía oscila de 20 a 40 vatios por 1000 cfm de capacidad (10 a
20 vatios por 1000 L/s).
Este tipo de filtro de aire puede remover y recoger contaminantes en el aire con promedios de
eficiencia de hasta 98% a velocidades de corrientes de aire bajas (150 a 350 fpm (0.75 a 1.75 m/s)]
cuando son comprobados por la Norma 52.1 de ASHRAE. La deficiencia disminuye (1) como las
placas colectoras llegan a cargarse con partículas, (2) con altas velocidades, ó (3) con velocidad no
uniforme.
Como con la mayoría de dispositivos de filtración de aire, el conducto se acerca hacia y desde
la caja del depurador de aire debe colocarse de manera que el flujo de aire es distribuido uniformemente sobre el área de la cara. Paneles de pre-filtros también deberán utilizarse para ayudar a distribuir el flujo de aire y para atrapar grandes partículas que pueden cortocircuitar o causar arco
excesivo dentro de la sección de alto voltaje.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Depuradores de Aire Electrónico
02.fm Page 48 Thursday, March 3, 2016 12:27 PM
Norma 52.2
Valor de
Informe de
Eficiencia
Minima
(MERV)
Contaminantes de Aire y Control
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Parámetros del Valor de Informe de Eficiencia Mínima (MERV)
de los Filtros
Eficiencia de Tamaño de Partícula
Promedio Compuesto, m
Margen 1
0.30–1
Margen 2
1.0–3.0
Margen 3
3.0–10.0
N/A
E3 < 20
N/A
N/A
E3 < 20
N/A
E3 < 20
N/A
N/A
E3 < 20
N/A
N/A
20  E3 < 35
N/A
N/A
35  E3 < 50
N/A
N/A
50  E3 < 70
N/A
N/A
70  E3
N/A
N/A
85  E3
E2 < 50
N/A
85  E3
50  E2 <65
N/A
85  E3
65  E2 <80
N/A
90  E3
80  E2
N/A
90  E1
90  E3
E1 < 75
90  E2
90  E3
75  E1 <85
90  E2
90  E3
85  E1 < 95
95  E2
95  E3
95  E1
Arrestancia
Resistencia
Promedio, %, Final Mínima,
por el Método de
pulg. de
la Norma 52.1
agua (Pa)
Aprom <65
65  prom <70
70  prom <70
75  Aprom
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.3 (75)
0.3 (75)
0.3 (75)
0.3 (75)
0.6 (150)
0.6 (150)
0.6 (150)
0.6 (150)
1.0 (250)
1.0 (250)
1.0 (250)
1.0 (250)
1.4 (350)
1.4 (350)
1.4 (350)
1.4 (350)
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
48
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 2.2
>90%
>90%
>85%
MERV 4
MERV 3
MERV2
MERV1
<20%
<20%
<20%
<20%
>70%
>70%
>65%
>65%
>85%
>90%
MERV 8
MERV 7
MERV 6
MERV 5
>97%
>95%
>95%
Proyectado para
Reemplazar 20 a
60% de polvo
Filtros de eficiencia
>98%
>99%
>99%
Método de Arrestancia
Margen de tamaño 1.0 a 3.0
µm: harina molida, polvo de
plomo, hollín de combustión,
Legionella, polvo de carbón,
alguna bacteria,polvo proceso
de molienda
margen de tamaño 3.0 a
10 µm: polen, polvo origen
tierra, esporas de moho, polvo
De cemento, leche en Polvo,
polvo de tabaco, Atomizador
para cabello
Margen de tamaño 0.3 a 1.0µm:
bacteria, humo (ETS),
pigmentos de pintura,polvo de
cara, algunos Virus, núcleos de
gotitas, polvos insecticidas,
humos de soldadura.
Partículas 0.12 a 0,5 µm: virus
(suelto), polvo de carbón, sal
marina, radón progenie, humo
de combustión
Ejemplo Gama de
Contaminantes
Controlados
Muestra de Tipo(s) de Filtros de Aire
Amplio margen de medios plegados, paneles de anillos,
cubos,
Bolsillos en sintético o fibra de vidrio, paneles desechables,
profundidad de 1 a 24 pulg. (25 a 600 mm).
Estilo de caja, tendido húmedo o fibra de vidrio, caja estilo
medio sintético, minipliegue sintético o papel fibra de
vidrio, profundidades de 2 a 12 pulg. (60 a 300 mm). Filtros
de bolsillo uno u otro rígido o flexible en sintético o fibra de
vidrio, profundidades de 12 a 36 pulg. (300 a 900 mm)
Estilo de caja, tendido húmedo o fibra de vidrio, caja estilo
medio sintético, minipliegue sintético o papel fibra de
vidrio, profundidades de 4 a 12 pulg. (100 a 300 mm),
Filtros de bolsillo de fibra de vidrio o medio sintético 12 a
36 pulg. (300 a 900 mm).
Protección de soplar suciedad grande de partículas y
Separadores de inercia
residuos, aire de ventilación ambiental industrial
Filtración de HVAC general, filtración de equipo
industrial, propiedad comercial, escuelas, prefiltros
a filtros de alta eficiencia, cabina de pintura,
protección equipos eléctricos/teléfono
Instalaciones de procesa miento de comida, plantas
de separación de aire, edificios comerciales mejor
residencial, depuradores de aire industrial, pre
filtración a filtros de alta eficiencia, escuelas,
gimnasios
Día de cirugía, cirugía general, ventilación hospital
general, equipos turbo, compresores, depurador de
aire de soldadura, pre filtros para HEPA, LEED
para (EB) Existente y nuevos edificios comerciales
(NC), Salones para fumadores.
SULPA >99.999% 0.1 a 0.2µm IEST tipo F (panel de
techo)
Sala blanca, elaboración farmacéuticos y escape,
SULPA >99.999% 0.3µm IEST tipo D (panel de techo)
material radioactivo de manejo y escape, cirugía de
HEPA >99.99% 0.3 µm IEST tipo C (techo o hasta 12 pulg.
trasplante de órgano y ortopédico, materiales
(300 mm)
cancerígenos, humos de soldadura.
HEPA >99.97% 0.3 µm IEST tipo A [estilo caja 6 a 12 pulg.
(150 a 300 mm)] profundo
Ejemplo de
Aplicaciones
Tabla 2.3 Pautas de Aplicación de Filtros [2012S, Ch 29, Tbl 2]
Valor de
Arrestancia
MERV 12
MERV 11 Proyectado para reemplazar 50
MERV10
a 80% de polvo filtros de
eficiencia
MERV 9
Proyectado para reemplazar 70
a 98% de polvo filtros de
eficiencia
N/A
Valor
Proyectado
Norma 52.1
MERV 14
MERV 16
MERV 15
MERV 17
MERV 18
MERV 19
MERV 20
Norma 52.2
MERV
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota: MERV para filtros HEPA/ULPA también incluye tasa de flujo de aire de prueba, pero no s mostrado aquí porque no es de importancia para el propósito de esta tabla.
N/A = no aplicable
Margen E-3
Margen E-2
Margen E-1
Filtros HEPA
02.fm Page 49 Thursday, March 3, 2016 12:27 PM
Contaminantes de Aire y Control
49
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Fuentes de Contaminantes
Exterior Típico
Equipo de combustión, motores, sistemas de
Monóxido de Carbono
calefacción defectuosos
Estufas, chimeneas, cigarrillos,
PM2.5
condensación de volátiles, Aerosoles, cocina
PM10
Combustión, sistema de calefacción, cocina
Combustión, solventes, productos de resina,
Vapores Orgánicos
pesticidas aerosoles, productos de limpieza,
materiales de construcción, pinturas
Sistema de calefacción
Dióxido de Azufre
Fuentes:
a EPA (2011)
b NRC (1981)
Ozono
Contaminantes
Biologicos
Dióxido de Carbono
Radón y Progenie
0.1 a
42 ppbc
N/A
600 a 1000 ppmc
1.3 pCi/La
0.3ppm3
<8 ppb2 (sin aparatos de
combustión)
>15ppb (con aparatos de
combustión)
20 µgm3b
(2 a 5 veces niveles exteriores)
Ubicaciones Típica
Casas, escuelas
N/A = no aplicable
ppb = partes por 10°
70 ppb3
Aviones, oficinas, casas
300 a 500 ppmc
N/A (más bajo que
Casas, hospitales, escuelas, oficinas,
los niveles
instalaciones públicas
interiores)
4 pCi/La
Casas, escuelas, oficinas
Mecánico/cuartos de calderas
<20 µg/m3b
3 ppb3
N/A
Casas, pistas de hielo interiores
Casas, restaurantes, instalaciones públicas,
oficinas, hospitales
Pistas de hielo interiores, carros, talleres de
reparación de vehículos, estacionamientos
Casas, oficinas, carros, instalaciones públicas,
bares, restaurantes
Casas, oficinas, transportación, restaurantes
15 ppb2
Ver Tabla 11
60 µg/m3a
Diferente para cada VOCc
<10 µg/m3a
7 a 10 µg/m3a
2 ppm2
Concentración
Exterior Típica
40 a 60 µg/m3a
Concentración
Interior Típica
0.5 a 5 ppm2 (sin estufas de gas)
5 a 15 ppm2 (con estufas de gas)
c Seppänen et al (1999) y Norma 62.1 de ASHRAE, Apéndice C
d Weschler (2001)
Aislamiento, productos de sujeción, productos
de madera prensada, alfombras
Materiales de construcción aguas subterráneas,
suelo
Artefactos de combustión, humanos, mascotas
Humanos, mascotas, roedores insectos,
plantas, hongos, humidificadores,
acondicionadores de aire
Arco eléctrico, limpiadores de aire electrónico,
copiadoras, impresoras
Combustión, estufas de gas, calentadores de
agua, secadoras de gas, cigarrillos, motores
Bióxido de Nitrógeno
Contaminante
Formaldehido
Contaminantes de Aire y Control
Tabla 2.4 Fuentes y Concentraciones Interior y Exterior de Contaminantes Interiores Seleccionados [2013F, Ch 11, Tbl 13]
02.fm Page 50 Thursday, March 3, 2016 12:27 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
50
1
2
1.2
2
2
2
2
1
1
2
1
PIA
1
1
1.2
1
1
1
1
1
1
2.2
1
2
1
2
1
2.1
1
1
1
1
1
2
1
2
AC
2
2
1
2
1
AIC
2
2.1
2
BIC
Contaminantes Gaseosos
Diclorofluoro metano
R-114 (ver nota)
Dietilamina
Dimetilamina
Ftalato de dioctilo
Dioxano
Etanol
Acetato etílico
Cloruroetílico (!)
Etileno (C2H4)
Oxido de etileno
Éter etílico
Etilmercaptano (!)
Formaldehido
Gasolina
Halocarbonos generales
Hidrocarburos genrales
General VOC
Heptano
Bromuro de hidrógeno
Cloruro de hidrógeno
Cianuro de hidrógeno
Fluoruro de hidrógeno
PIA AC AIC BIC Contaminantes Gaseosos PIA
Formiato de Metilo
1
2
Metil Isobutil Cetona
1
2
Sulfuro de Metilo
1
2
1
Metil isobutil cetona
2
1
2
Nafta
1
Naftalina
2
1
Nicotina
2
1
1
Acido nítrico
1
2
Oxido nítrico (NO)
1,2 2,1
1
Nitrobenceno
1
Bióxido de nitrógeno
2
1
1
Nitrometano
1
2
1
2 Oxido nitroso
1–1 2
Octano (!)
1
2
Ozono (O3) (!)
1
2
1
2
Percloroetileno
1
2
Nitrato acetil peróxido
1
2
2
Fenol
1
2
Fosgeno
1 Fosfeno
2
1
1 Putrescina
2
1
1
Piridina (!)
1 Escatol
1
2
Tabla 2.5 Selección de Medios por Contaminante [2011ª, Ch 46, Tbl 7]
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Contaminantes Gaseosos
Acetaldehido
Acido acético (!)
Anhídrido acético
Acetona (!)
Acetileno
Acroleína
Acido acrílico (!)
Sulfuro de alilo
Amoniaco (NH3)
Anilina
Arsina
Benceno
Borano (!)
Bromo
1,3 butadieno
Butano
2-butanona
2-butoxietanol
Acetato de butilo (!)
Alcohol butílico
Butil mercaptano
Butileno
Butino
02.fm Page 51 Thursday, March 3, 2016 12:27 PM
Contaminantes de Aire y Control
51
2
1
1
1.1
1.1
1
1
1
1
1
1
1
1
2
AC
1
1
AIC
1
2
1
2
BIC
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Contaminantes de Aire y Control
Contaminantes Gaseosos
Yoduro de hidrógeno
Seleniuro de hidrógeno
Sulfuro de Hidrógeno
Yodo
Yodoformo
Isopropanol
Queroseno
Acido láctico
Mentol
Vapor de mercurio
Metanol
Acrilato de metilo
Bromuro de metilo (!)
Metil butil cetona (!)
Acetato de metil selosolve
Metilcoroformo
Metilciclohexano
Cloruro de metileno
2
1
2
1
2.1
1
1
1.1
1
1
1
1,1
AC
1
AIC
2.2
1
1
1
BIC
Comentarios: Algunas moléculas contaminantes tienen isómeros que debido a que tienen
diferentes propiedades físicas (punto de ebullición, presiones de vapor), requieren diferentes métodos de tratamiento. Para algunos contaminantes, el tratamiento preferido es
intercambio iónico u otro (no en lista) carbón impregnado. Para algunos contaminantes,
las recomendaciones del fabricante difieren. “!” es utilizado para identificar estos casos.
PIA AC AIC BIC Contaminantes Gaseosos PIA
2
Silano
1
Disolvente de Stoddard
1
1
1 Stibine
1
1
Estireno (!)
2
2
1
Dióxido de Azufre
1
2
1
Trióxido de Azufre
1
1
Acido sulfúrico
1
Tolueno
2
1
Trietilamina
Impreg. AC
Tricloroetileno
2
1
1,1,1, tricloroetano (!)
1
2
1
R-11 (ver abajo)
2.1 1
Trementina
2
1.2 2,1
Urea (!)
2
2
1
Acido úrico (!)
1
1
Cloruro de vinilo
1
Xileno
1
Tabla 2.5 Selección de Medios por Contaminante [2011ª, Ch 46, Tbl 7] (Continuo)
AC AIC BIC
1
1
2
2
1
1
Carbon con catalizador
2
1
Carbon con catalizador
1
1
1
1.2
2.1
1
2
1
2
1
1
1
1
1
PIA
2
1 = selección de medios primarios para contaminante, 2 = selección medios secundarios.
PIA = alumina impregnado de permanganato; AC = carbón activado; AIC = carbón impregnado de ácido;
BIC = base de carbón impregnado.
R-114 es diclorotetra fluoretano: R-11 es tricloro fluorometane
Contaminantes Gaseosos
Butiraldehido
Acido butírico
Cadaverina
Alcanfor
Dióxido de carbono
Disulfuro carbono
Monoxido carbono
Tetracloruro de carbono
Cloro (C12)
Cloroformo
Creosota (!)
Ciclohexano
Ciclohexanol
Ciclohexanona
Ciclohexeno
Decano
Diborano
Diclorobenceno
02.fm Page 52 Thursday, March 3, 2016 12:27 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
52
3.6 (n.d – 41)
11 (n.d – 59)
11 (n.d – 68)
1900 (270 – 9100)
4.9 (1.7 – 11)
32 (3.2 – 150)
8.4 (n.d – 85)
2.8 (n.d – 37)
19 (n.d – 46)
400 (52 – 850)
9.0 (n.d – 32)
8,4 (n,d – 26)
35 (n.d – 290)
140 (n.d – 290)
220 (n.d – 570)
3.0 (n.d – 8.2)
21 (n.d – 53)
Tableros de
Fibra de Vidrio
15 (n.d – 61)
10 (n.d – 28)
6.8 (n.d –19)
37 (n.d – 110)
Tableros de
Yeso
2500 (170 – 6200)
3.7 (n.d – 24)
35 (n.d – 120)
19 (n.d – 190)
Pinturas en Tableros
de Yeso
Promedios de Factor de Emisión (márgenes), µg/(h·m2)
Alfombras
5,8 (n.d – 25)
12 (n.d – 33)
Tableros Acústicos
de Techo
420 (240 – 510)
160 (140 – 200)
49 (n.d – 97)
28 (n.d – 55)
Tableros de
Particulas
Ejemplo de Generación de Contaminantes Gaseosos por Materiales de Construcción [2011ª, Ch 46, Tbl 2]
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
4-Fenil ciclo hexano (PCH)
Acetaldehido
Acido acético
Acetona
Glicol etileno
Formaldehído
Naftalina
n-Heptano
Nonanal
Tolueno
TVOC*
Contaminante
Tabla 2.6
02.fm Page 53 Thursday, March 3, 2016 12:27 PM
Contaminantes de Aire y Control
53
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
680 (100 – 2100)
160 (6.3 – 310)
6.6 (6.6)
Tableros de
Yeso
15000 (1500 – 100000) 270 (100 – 430)
1.4 (n.d – 11)
5.7 (n.d – 19)
35 (n.d – 310)
5.1 (n.d – 12)
5.6 (n.d – 28)
1.3 (n.d – 20)
Tableros de
Fibra de Vidrio
210 (n.d – 590)
1.6 (n.d – 24)
38 (n.d – 210)
6.8 (n.d – 79)
3.4 (n.d – 14)
2,7 (n.d – 24)
11 (n.d – 49)
120 (n.d – 830)
0.51 (n.d – 5.1)
Alfombras
7.5 (0.57 – 26)
1.8 (0,57 – 4)
5.9 (0.35 – 14)
12 (1.8 – 21)
Pinturas en Tableros
de Yeso
Promedios de Factor de Emisión (márgenes), µg/(h·m2)
9.4 (4.4 – 19)
13 (n.d – 29)
75 (4.8 – 150)
Tableros Acústicos
de Techo
140 (13 – 270)
7100 (1200 – 13000)
10)
340 (n.d – 680)
32 (3.6 – 61)
220 (30 – 400)
Tableros de
Particulas
Ejemplo de Generación de Contaminantes Gaseosos por Materiales de Construcción [2011ª, Ch 46, Tbl 2] (Continuo)
Contaminantes de Aire y Control
Fuente: Estudio de Emisiones de Materiales, Consejo de Administración de Residuos Integrado de California, Publicación 433-03-015,2003
n.d = no detectable
* TVOC concentraciones calculadas de la corriente ion total (TIC) del análisis GC/MS agregando áreas de picos integrados con tiempos de retención mayores de 5 min., substrayendo de la suma del área
de clorobenceno-d5 estándar interno y utilizando factor de respuesta del clorobenceno-d5 como la calibración.
1,2,4 trimetrilbenceno
2- Butoxi-etanol
Acetaldehido
Acetona
Acido butírico
Dodecano
Glicol etileno
Formaldehído
Naftalina
n-butano
Nonanal
Octano
Fenol
Tolueno
Undecano
TVOC*
Contaminante
Tabla 2.6
02.fm Page 54 Thursday, March 3, 2016 12:27 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
54
02.fm Page 55 Thursday, March 3, 2016 12:27 PM
Instalación
Tabla 2.7 Ventajas y Desventajas de Ubicación
de Accesorios UVC Relativos a la Bobina
Ubicación
Ubicación Ventajas Desventajas
Más espacio para instalar accesorios
Permite a los accesorios irradiar
mejor la superficie donde la condensación es más alta.
• Permite a los accesorios irradiar generalmente la parte más contaminada
del ventilador y bandeja de drenaje.
• La lámpara y accesorio deben estar
sometidos a menos humedad.
• Puede ser la única ubicación para
aplicar los accesorios.
• Pocas lampara y accesorios se pueden
necesitar que en el lado de aguas
abajo.
•
•
Corriente
abajo
Corriente
arriba
•
•
•
•
Desventajas
La lámpara y herramienta debe estar aprobado
para lugares mojados
Los efectos de enfriamiento de la lámpara
puede reducir la potencia de radiación UV, o
requiere corrección de la sensación térmica o
más lámparas y accesorios para un resultado
determinado
No puede permitir suficiente espacio para instalar accesorios.
Inicialmente puede tomar más tiempo para limpiar bobina y no puede desinfectar la bandeja de
drenaje
55
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Las bobinas deben ser limpiadas inicialmente para reducir la biomasa y acelerar la limpieza
amplia del sistema y ahorros de energía. Las lámparas ultravioletas UV deben ser instaladas cerca
de las bobinas de enfriamiento y espaciadas para permitir distribución uniforme de energía sobre
la superficie a ser desinfectada. Fabricantes de equipos ultravioletas UV calificados o consultores
pueden ayudar en el diseño del sistema.
Los accesorios UVG1 para equipos HVAC deben ser diseñados para resistir humedad y condensado (de las bobinas o causado por la reducción de temperaturas de operación) y para operar
correctamente sobre toda la gama de las temperaturas de funcionamiento del sistema. Debe tenerse cuidado en el sitio de instalación para asegurar que los enclavamientos eléctricos están incluidos para desconectar el sistema UV cuando se accede. Sistemas UV operarán continuamente para
maximizar los beneficios de UV y para mejorar la vida de la lámpara y para contrarrestar el moho
y crecimiento de bacteria que ocurre cuando un sistema HVAC no está operando.
Los trabajadores deben ser conscientes de los peligros en el área de trabajo y entrenados en
precauciones para protegerse ellos mismos. Los trabajadores que deben limpiar las lámparas rotas
deben ser entrenados en protección propia, limpieza y eliminación.
Acceso a las lámparas sólo debe ser permitido cuando las lámparas están desconectadas. Las
lámparas deben ser apagadas antes de la unidad de tratamiento de aire (AHU) o apagado del ventilador para permitir a las lámparas enfriarse y para vaciar todo el ozono en la cámara de la lámpara (si lámparas productoras de ozono son utilizadas). Si las unidades de tratamiento de aire
(AHU) o ventiladores son apagadas primero, la cámara de la lámpara debe ser abierta y permitida
ser ventilada por varios minutos. Los trabajadores deben siempre utilizar gafas de protección y
guantes resistentes a punción para protección en caso de que una lámpara se rompa.
Contaminantes de Aire y Control
Las lámparas UVC (onda corta, 80 a 200 mm) son más efectivas para inactivación de microorganismos, para aire de habitación superior y para conductos interiores. UVC es mucho menos
penetrante que la onda más larga UV, pero puede dañar ojos y piel. También puede degradar materiales orgánicos como empaques, caucho, aislamiento y tubería plástica. Sistemas de irradiación
en la habitación están diseñados para irradiar aire en la parte superior de una habitación. Convección natural distribuirá el efecto de irradiación.
Sistemas de desinfección de corriente de aire en conductos UVC son generalmente diseñados
para obtener un nivel requerido de desinfección de aire. Los aditamentos UV están instalados en
los conductos de suministro.
Como los equipos de calefacción, ventilación y aire acondicionado (HVAC) envejecen, su
rendimiento puede degradarse, y por consiguiente la calidad del aire que lleva a los espacios ocupados. Las bobinas de enfriamiento pueden actuar como filtros para recoger y retener una cantidad sustancial de partícula, incluyendo microbios. Estos materiales son bastante pequeños, por lo
que esto ocurre aún en un sistema con filtración razonable o buena. Entre un 30 y 100%, las condiciones de las bobinas húmedas y depósitos de desagüe son un foro excelente para el crecimiento
de bacteria y moho. El ensuciamiento de las bobinas también incrementa la caída de presión de las
bobinas y reduce el flujo de aire, reduciendo la transferencia de calor de las aletas de las bobinas
para disminuir la cantidad de trabajo un sistema puede desarrollar y reducir la calidad ambiental
interior (EIQ). Puede contribuir al síndrome del edificio enfermo y las enfermedades relacionadas
con el edificio que van desde irritaciones leves a la propagación de agentes infecciosos. La acumulación de descomposición es a menudo una fuente de olor, también.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Sistemas de Lámparas Ultravioletas
02.fm Page 56 Thursday, March 3, 2016 12:27 PM
Contaminantes de Aire y Control
Vista de Elevación Típica de una Habitación Superior UV Aplicado en la Habitación de
un Paciente de Hospital
Figura 2.4 Lámpara UVGI Típica
56
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 2.3 Lámparas UV Corriente Arriba o Corriente abajo de Bobina y Bandeja de Drenaje
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 2.2
02.fm Page 57 Thursday, March 3, 2016 12:27 PM
Para seleccionar una tasa de flujo volumétrico adecuado para sacar aire a través de una campana, seleccione una velocidad de captura, lo cual es velocidad de aire al punto de generación de
contaminantes. El contaminante entra a la corriente de aire en movimiento al punto de generación
y es llevado a cabo a lo largo con el aire dentro de la campana. La Tabla 2.8 muestra las velocidades de captura para varias operaciones industriales, basado en experiencia exitosa bajo condiciones ideales.
Extremo Superior del Margen
1. Distribución de corrientes de aire de
habitación
Contaminantes de Aire y Control
Extremo Inferior del Margen
1. Corrientes de aire de habitación son
favorables para captura
2. Contaminantes de toxicidad baja o sólo valor
de estorbo
3. Intermitente, baja producción
4. Campana grande, gran masa de aire en
movimiento
2. Contaminantes o alta toxicidad
3. Producción alta, uso intensivo
4. Campana pequeña, sólo control local
Principios de Optimización de Diseño de Campana
•
•
•
•
•
Tabla 2.8
Condiciones de Dispersión
de Contaminantes
Margen de Velocidades de Captura
Ejemplos
Velocidad de Captura
(control), fpm (m/s)
Liberado esencialmente sin
Evaporación de tanques,desengrase,
50 a 100 (0.25 a 0.50)
velocidad en aire quieto
enchapado
Liberado a velocidad baja en Llenada de contenedores, transferencia de
100 a 200 (0.5 a 1.0)
moderadamente aire quieto transportadoras de baja velocidad, soldadura
Generación activa en zona de Llenada de barriles, canaleta de carga de
200 a 500 (1.0 a 2.5)
rápido movimiento de aire
transportadoras, triturador, sacudida fría
Liberado a velocidad alta en
Molienda, limpieza abrasiva, pulido,
zona de movimiento de aire
500 a 2000 (2.5 a 10)
sacudida caliente.
muy rápida
Para cada condición de arriba, un margen de velocidades de captura es mostrado. La elección propia de valores
depende en varios factores.
57
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
•
La ubicación de la campana debe estar tan cerca como sea posible a la fuente de contaminación.
La abertura de la campana estará posicionada de modo que cause al contaminante desviarse menos de su camino natural.
La campana debe estar situada de modo que el contaminante es apartado de la zona de
respiro del operador.
El tamaño de la campana debe ser la misma que o más grande que la sección transversal
de flujo que entra en la campana. Si la campana es más pequeña que el flujo, una tasa de
flujo volumétrico mayor es necesaria.
La posición del trabajador con relación a la fuente contaminante, diseño de campana y
camino de la corriente de aire debe ser evaluado basado en los principios dados en los
Capítulos 6 y 3 de ACGIH (2007).
Campanas con dosel no deben utilizarse donde el operador debe de agacharse sobre un
tanque o proceso (ACGIH 2007).
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Velocidades de Captura de Campana
Figura 2.5 Contornos de Velocidad para Abertura Redonda Plana
58
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 2.6 Contornos de Velocidad para una Abertura Rectangular Plana con Lados en una
Proporción de 1:3
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Contaminantes de Aire y Control
02.fm Page 58 Thursday, March 3, 2016 12:27 PM
02.fm Page 59 Thursday, March 3, 2016 12:27 PM
Consideraciones de Conductos
Tabla 2.9 Velocidades de Transporte de Contaminantes [2011A, Ch 32, Tbl 2]
Naturaleza del
Contaminante
Ejemplos
Vapor, gases,
humo
Todos los gases de vapor
Humos
Soldadura
Polvo de luz
muy fino
Fibra de algodón, harina de madera, polvo litográfico
Polvo húmedo y
excesivo
Polvo de plomo con pequeñas partículas, polvo de cemento
húmedo, trozos de asbesto de máquinas cortadoras de tuberías,
pelusa de pulido (pegajoso), polvo de cal viva
2500 a 3000
(13 a 15)
3000 a 4000
(15 a 20)
3500 a 4000
(18 a 20)
4000 a 4500
(20 a 23)
4500 (23) y
hacia arriba
Fuente: de la Conferencia Americana de Higienistas Industriales Gubernamentales (ACGIH), Ventilación Industrial:
Un Manual de Práctica Recomendado, 27th ed. Propiedad literaria 2010. Reimpresión con permiso.
59
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Polvos secos y Polvo de caucho fino, polvo de moldeo, pelusa de yute, polvo de
polvos
algodón, virutas, polvo de jabón, virutas de cuero
Polvo de molienda, pelusa de pulido(seco), polvo de yute de
lana(residuos agitador), granos de café, polvo de zapatos, polvo de
Polvo industrial
granito, harina de sílice, manejo de material en general, corte de
promedio
ladrillo, polvo de arcilla, fundición (general) polvo de piedra
caliza, polvo de asbesto en industrias textiles
Aserrín (pesado y mojado), torneado de metales, barriles de
fundición y agitador, polvo de chorro de arena, bloques de
Polvo excesivo
madera, excremento porcino, latón torneado, polvo pesado de
hierro fundido, polvo de plomo
Velocidad de
Transporte
Mínima,
fpm (m/s)
Usualmente
1000 a 2000
(5 a 10)
2000 a 2500
(10 13)
Contaminantes de Aire y Control
El segundo componente de un sistema de ventilación de escape local es el conducto a través
del cual el aire contaminado es transportado de la campana(s). Conductos redondos son preferidos
porque ellos (1) ofrecen una velocidad de aire más uniforme para resistir sedimentación del material y (2) pueden resistir las presiones estáticas más altas normalmente encontradas en sistemas de
escape. Cuando las limitaciones de diseño requieren conductos rectangulares, la relación de
aspecto (relación de altura a anchura) debe estar tan cerca a la unificación como sea posible.
Velocidad de transporte mínimo es la velocidad requerida para transportar partículas sin
sedimentación. La Tabla 2.9 enumera algunas velocidades de transportación generalmente aceptadas como una función de la naturaleza de contaminantes. Los valores enumerados son típicamente
más altos que valores teoréticos y experimentales para dar razón de (1) daños a conductos lo cual
incrementará la resistencia del sistema y reducirá el flujo volumétrico, (2) filtración del conducto,
el cual tiende a reducir la velocidad en el sistema del conducto aguas arriba de la fuga, (3) erosión
o corrosión de la rueda del ventilador y/o deslizamiento de la correa, lo cual puede reducir el volumen del ventilador, y (4) re-encausamiento de partículas sedimentadas causado por operación
errónea del sistema de escape. Las velocidades de diseño pueden ser mayores que las velocidades
de transporte mínimas, pero nunca deben ser significantemente menores.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Diseño de Conductos de Escape y Construcción
02.fm Page 60 Thursday, March 3, 2016 12:27 PM
Cuando el aire entra en la campana, ocurre una pérdida de presión total, la pérdida de entrada
de campana es
Contaminantes de Aire y Control
pe = Co pv
donde
pe
=
pérdida de entrada de campana, pulg. de agua (Pa)
Co
=
factor de pérdida, sin dimensiones
Pv
=
presión de velocidad apropiada, pulg. de agua (Pa)
La presión total es difícil de medir, ya que esto varía a través de un conducto, dependiendo en
la velocidad local. Por otra parte, la presión estática permanece constante a través de un conducto
recto. Por consiguiente, una sola medición de la presión estática en un ducto recto aguas abajo de
la campana puede monitorear la tasa de flujo volumétrico. El valor de esta presión estática, succión de a campana, es dado por
phs = pv + pe
donde Phs = succión de campana, pulg. de agua (Pa).
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 2.7 Pérdidas de Entrada para Campanas Típicas
60
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Pérdida de Entrada de Campana
02.fm Page 61 Thursday, March 3, 2016 12:27 PM
Campanas
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
61
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Contaminantes de Aire y Control
Campanas Tipo I. Campanas Tipo I para remoción de grasa y humo no están en la lista, las
cuales reúnen el diseño, construcción y criterios de rendimiento de los códigos local y nacional aplicables y no son permitidos tener amortiguadores de escape accionados por el fuego, o enumerados con
diseño, construcción y rendimiento a la Norma 710 UL. El Tipo II se refiere a todas las otras campanas.
Entre las campanas enumeradas Tipo I, hay dos sub categorías básicas, (1) campanas de
escape sin amortiguadores de escape y (2) campanas de escape con amortiguadores de escape.
En los dispositivos de remoción de grasa en el Tipo I las campanas operan sobre el principio
en el cual una fuerza centrífuga es creada como el aire de escape pasa alrededor de los tabiques
para extraer la grasa. Tipos de dispositivos:
• Filtros deflectores tienen una serie de deflectores verticales diseñados para capturar
grasa y drenarla en el contenedor. Los filtros están ordenados en un canal o receptáculo
para fácil inserción y remoción para limpieza. Cada campana usualmente tiene dos o más
filtros deflectores, los cuales están construidos típicamente de aluminio, acero o acero
inoxidable y vienen en varios tamaños estándares. Los filtros son limpiados en una lava
vajillas o jabonándolos y enjuagándolos. La Norma 96 NFPA requiere que los filtros de
grasa sean enumerados. Filtros de grasa enumerados son probados y certificados por un
laboratorio de prueba reconocido nacionalmente de acuerdo con la Norma UL 1046.
• Extractores Desmontables (también llamados filtros de cartucho) tienen una sola ranura
horizontal de entrada de aire. Los filtros están ordenados en un canal o receptáculo para fácil
inserción y remoción para limpieza. Cada campana usualmente tiene dos o más extractores
desmontables, los cuales están típicamente construidos de acero inoxidable y contienen una
serie de deflectores horizontales diseñados para remover grasa y drenarla en un contenedor.
Disponible en varios tamaños, son limpiados a través de una lava vajilla o jabonando y enjuagando. Los extractores desmontables pueden ser clasificados por un laboratorio de prueba
reconocido nacionalmente de acuerdo con la Norma UL 1046, o pueden ser cotizados como
parte de la campana de acuerdo con la Norma UL 710. Las campanas que son cotizadas con
extractores desmontables no pueden tener esos extractores reemplazados por otros extractores.
• Extractores estacionarios son integrantes de las campanas de extracción de lavado con agua
enumeradas y son típicamente construidas de acero inoxidable y contienen una serie de
deflectores horizontales que recorren la longitud completa de la campana. Los deflectores no
son desmontables para limpieza, aunque algunos tienen puertas que pueden ser removidas
para limpiar los extractores y pleno. El extractor estacionario incluye una o más colectores de
agua con boquillas de pulverización, que cuando se activan, lavan la grasa del extractor con
agua caliente inyectada de detergente, removiendo la grasa acumulada. El ciclo de lavado es
típicamente activado al final del día, después que el equipo de cocina y ventiladores han sido
apagados, sin embargo, puede ser activado más frecuentemente. El ciclo dura de 5 a 10 minutos, dependiendo del fabricante de la campana, tipo de cocina, duración de operación y temperatura del agua y presión. La mayoría de los fabricantes de campanas de lavado con agua
recomiendan una temperatura de agua de 130 a 180°F (55 a 80°C) y presión de agua de 10 a
80 psi (200 a 550 kPa). El promedio de consumo de agua varía de 0,50 a 1.50 gpm por pie
lineal (0.1 a 0.3 L/s por metro lineal) de campana, dependiendo del fabricante. La mayoría de
los fabricantes de campanas de lavado con agua proporcionan un manual y/o medios
automáticos de activar el sistema de lavado con agua en el evento de un incendio.
Algunos fabricantes de campanas de lavado con agua proporcionan agua fría continua
como una opción. El agua fría funciona continuamente durante la cocción y puede o no ser
recirculada, dependiendo del fabricante. El uso típico del agua fría es 1 gph por pie lineal
(3.5 mL/s por metro lineal) de campana. La ventaja de este método es que mejora la extracción
de la grasa y la eliminación, en parte a través de la condensación de la grasa. Muchos fabricantes de campanas recomiendan agua fría continua en campanas situadas sobre equipos de
cocina que queman combustible sólido, porque el agua también extingue brasas calientes que
pueden ser echadas dentro de la campana y ayuda a enfriar la corriente de escape.
• Filtros de Etapas Múltiples utilizan dos o más etapas de filtración para remover un gran porcentaje de grasa. Típicamente consiste de un filtro deflector o extractor desmontable seguido
por un filtro de mayor eficiencia, como una cama de empaquetado. Cada campana usualmente
tiene dos o más filtros de etapas múltiples, que son típicamente construidas de aluminio o
acero inoxidable y están disponibles en tamaños estándares. Los filtros son limpiados en una
lava vajilla o por jabón y enjuague. La Norma 96 de NFPA requiere que los filtros de grasa
sean enumerados, por lo que estos filtros de etapa múltiple deben ser probados y certificados
por un laboratorio de prueba reconocido nacionalmente de acuerdo con la Norma 1046 de UL.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Ventilación de Cocina (Ver NFPA 96 y Norma 154 de ASHRAE)
02.fm Page 62 Thursday, March 3, 2016 12:27 PM
Contaminantes de Aire y Control
Tipo de Campana
(No Cotizado)
Dosel montado en la
pared
Una sola isla
Isla doble (por lado)
Ceja
Estante trasero
Saliente Final
Saliente Frontal
Saliente Posterior
6 pulg. (154 mm)
6 pulg. (154 mm)
N/A
6 pulg. (154 mm)
6 pulg. (154 mm)
6 pulg. (154 mm)
6 pulg. (154 mm)
6 pulg. (154 mm)
N/A
N/A
N/A
6 pulg. (154 mm)
6 pulg. (154 mm)
10 pulg. (254 mm) (revés)
N/A
Tasa de Flujo de Escape neto Mínimo, cfm (L/s) por Pie Lineal [Metro]
de Longitud de Campana
Equipo de Trabajo
Equipo de
Equipo de
Equipo de Trabajo
Liviano
Trabajo Medio Trabajo Pesado
Extra Pesado
200 (310)
300 (464)
400 (619)
550 (850)
400 (619)
250 (387)
250 (387)
300 (464)
500 (774)
300 (464)
250 (387)
300 (464)
600 (929)
400 (619)
No permitido
400 (619)
700 (1085)
550 (850)
No permitido
No permitido
N/A = no aplicable
Excepciones:
1. Paneles Laterales. La saliente no es necesaria donde los paneles laterales completos o paneles laterales parciales
(paneles en ángulo desde el borde frontal de la campana a la parte trasera de la campana a la altura de la superficie
de cocción) son suministrados para reducir el área abierta entre los artefactos y la campana.
2. Campanas enumeradas deben ser instaladas de acuerdo con los términos del listado de la organización y de las
instrucciones de instalación de su fabricante.
Tabla 2.11
Campana Extractora de Cocina Presión Estática de Escape Pérdidas
por Campanas para Diversas Corrientes de Aire de Escape
Filtro deflector
Extractor
Pérdida de Presión Estática. Pulg. de calibre de agua (Pa)
250 a 350 cfm/pie
350 a 450 cfm/pie
500+ cfm/pie
150 a 250 cfm/pie
(0.8 a 1.3 m3/s per m) (1.3 a 1.8 m3/s per m) (1.8 a 2.3 m3/s per m) (2.5 + m3/s per m)
0.25 a 0.50
(60 a 120)
1.00 a 1.35
(250 a 340)
0.50 a 0.75
0.75 a 100
1.00+
(120 a 190)
(190 a 250)
(250+)
1.30 a 1.70
1,70
1.70
(320 a 420)
(420)
(420)
Campanas Tipo II. Las campanas tipo II pueden ser divididas en las dos siguientes categorías de aplicaciones:
• Campana de Condensado. Para escape de humedad alta, el condensado se formará en
el interior de las superficies de las campanas. La campana está diseñada para dirigir el
condensado hacia un canalón perímetro para colección y drenaje. Las tasas de flujo
son típicamente 50 a 75 cfm por pie cuadrado (0.25 a 0.38 m3 por metro cuadrado) de
abertura de la campana. El material de la campana usualmente es anticorrosivo y los
filtros son usualmente instalados.
• Campana de calor/humo. Para aplicaciones sobre equipo que produce calor y humos solamente, las tasas de flujo son típicamente 50 a 100 cfm por pie cuadrado (0.25 a 0.50 m3/s
por metro cuadrado) de abertura de campana. Los filtros usualmente no son instalados.
Opciones de Aire de Recuperación
El aire que sale del espacio de la cocina debe ser reemplazado. Puede ser recogido a través de registradores de techo situados de tal forma que el aire descargado no interrumpe el patrón de aire que
entra en la campana. El aire debe ser suministrado (1) tan lejos de la campana como sea posible o
(2) cerca de la campana y que se aleje de la campana o hacia abajo a velocidad muy baja. El aire de
recuperación, descarga interna, lleva aire al interior de la campana sin entrar en el espacio ocupado.
62
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tipo de
Dispositivo de
Extracción de
Grasa
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 2.10 Requisitos Salientes Mínimos
Tipo de Campana
Dosel montado
en la pared
Dosel de una
sola isla
Dosel de
doble isla
Ceja
Estante trasero
02.fm Page 63 Thursday, March 3, 2016 12:27 PM
Figura 2.8
Campana de Humo de Derivación con Marco Vertical y Entrada de Aire de Derivación
[2011A, Ch 16, Fig 1]
63
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Las operaciones de laboratorio potencialmente involucran peligro. Uso de gabinetes de seguridad biológica pueden ser requeridos. Revisar los parámetros de diseño del laboratorio con oficial
de seguridad y personal científico.
Contaminantes de Aire y Control
Campanas de Laboratorio
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Sistemas de Conductos
La red de conductos de escape conduce el aire de escape al exterior, con cualquier grasa, humo, VOC
y olores. Para ser efectivo, la red de conductos debe ser engrasada y libre de combustibles; y los conductos
deben ser dimensionados para transmitir el volumen de aire necesario para remover el efluente. La red de
conductos no deben tener trampas que puedan mantener grasa y los conductos deben inclinarse hacia la
campana para drenaje constante de grasa licuada o condensados. En los recorridos largos de conductos,
una tolerancia debe permitirse para expansión térmica posible debido a un incendio. La velocidad mínima
del conducto es 500 pie/min. (25 m/s). Paneles de acceso son requeridos para limpieza.
Ventiladores de Extracción
Los ventiladores de extracción de cocina deben ser capaces de soportar aire cargado de grasa
y calor. El ventilador debe ser diseñados para mantener el motor fuera de la corriente de aire y
enfriado efectivamente. Situado en el techo es preferido. Para prevenir daño del techo, el ventilador debe contener y drenar adecuadamente toda la grasa removida de la corriente de aire.
Los siguientes tipos de ventiladores de extracción están en uso común (todos tienen ruedas
centrífugas con las paletas inclinadas hacia atrás).
• Descarga Vertical. Ventiladores de aluminio para ser montados en techo directamente en
la parte superior del tubo de escape, con descarga hacia arriba enumerada para el servicio.
Ellos típicamente pueden proporcionar presiones estáticas de sólo hasta 1 pulg. de agua
(250 Pa). Estos ventiladores permiten fácil acceso para limpieza del conducto porque
ellos generalmente dependen de vuelta desde el conducto.
• Conjunto de utilidad. Ventiladores de acero, montados en el techo, un solo ancho, una
sola entrada. Pueden operar a presión estática media a alta. Debe tenerse cuidado de drenar la parte baja del ventilador a un contenedor remoto seguro.
• En Línea. Ventiladores de acero típicamente ubicados en el tramo del conducto dentro de un edificio donde el montaje del ventilador exterior no es práctico para pared o escape de techo. La
brida de montaje con junta debe ser engrasada, sin embargo removible para servicio. Una bandeja
debe ser colocada bajo el ensamblaje entero en el evento de una fuga de grasa en las bridas.
Extinción de Fuego
Los sistemas de escape que sirven al equipo que produce grasa deben incluir un sistema de
extinción de fuego a menos que dispositivos de remoción de gasa enumerados sean instalados. Sistemas de químicos secos con boquillas sobre el equipo de cocina, en la campana y en el collar del conducto aguas abajo de la campana son comúnmente utilizados, de acuerdo a NFPA 17A. Agua de los
sistemas de rociadores de las tuberías húmedas pueden ser utilizados, de acuerdo a NFPA 13.
02.fm Page 64 Thursday, March 3, 2016 12:27 PM
64
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Contaminantes de Aire y Control
Las partículas en el aire incluyen polen, bacterias y polvo arrastrado por el viento y espuma
de mar. La industria genera partículas de combustión, vapores químicos y fricción en equipos. La
gente es la fuente principal de partículas, como escamas de piel, pelusa, cosméticos y emisiones
respiratorias. Las partículas en el aire varían en tamaño de 0.001 µm a varios cientos de micras.
Las partículas mayores de 5 µm tienden a asentarse rápidamente.
El personal de sala blanca es potencialmente la fuente más grande de partículas internas. Las
partículas generadas por el personal son controladas con flujo de aire diseñado para continuamente “lavar” al personal con aire limpio, nuevos vestidos para sala blanca y procedimientos de
vestimenta apropiada.
Las partículas generadas externamente son prevenidas de entrar en la sala blanca con filtros
de aire de alta eficiencia centrados alrededor de dos tipos: filtros de aire de partículas de alta eficiencia (HEPA) y filtros de aire de penetración ultra baja (ULPA). Los filtros HEPA son más frecuentemente utilizados.
Ambos filtros HEPA y ULPA utilizan tecnología de papel de fibra de vidrio. Tienen plisadas
profundas ya sea con aluminio, cuerda cubierta, o papel de filtro como separadores plegados. Los
filtros puede variar de 2 a 12 pulg. (50 a 300 mm) en profundidad; en consecuencia, área de
medios mayor está disponible con filtros profundos y espacio de pliegues más concentrados.
Los filtros fibrosos tienen su eficiencia de remoción más baja en el tamaño de la partícula más
penetrante (MPPS), determinado por el diámetro de la fibra del filtro, fracción de volumen o densidad de empaquetamiento y velocidad del aire. Para la mayoría de los filtros HEPA la MPPS está
entre 0.1 y 03 µm. Así filtros HEPA y ULPA tienen eficiencias evaluadas basadas en 03 µm y 0.12
µm tamaño de partículas, respectivamente.
La selección de las configuraciones del patrón de aire es el primer paso para el diseño de la
sala blanca. Los requisitos para el nivel de limpieza, disposición de equipos de proceso, espacio
disponible para instalación de equipos de control de aire todo influye en la selección del diseño
del patrón de aire. El proyecto de los aspectos financieros pueden limitar el tipo y tamaño del
equipo de manejo de aire a ser utilizado y control del patrón de aire resultante.
Flujo de aire unidireccional, es aire que fluye en un solo paso en una sola dirección a través
de la sala blanca o zona limpia con generalmente líneas de corriente paralelas. Aunque el personal
y equipo en la corriente de aire distorsiona las líneas de corriente, la velocidad constante es aproximada.
Flujo de aire no unidireccional puede tener características de circulación de pases múltiples o
una dirección de flujo no paralelo.
El flujo de aire no unidireccional puede proveer resultados de control de contaminación satisfactorios para niveles de limpieza de ISO Clase 6 hasta ISO Clase 8.
Cuando las partículas generadas internamente son de preocupación primaria, estaciones de
trabajo limpio son proporcionadas en el espacio limpio.
Patrones de aire y reducción de turbulencia de aire son optimizados en sistemas de flujo de
aire unidireccional. En un cuarto de flujo laminar vertical (VLF), el aire es introducido a través del
techo y retornado a través de un techo elevado o en la base de paredes laterales.
En una sala blanca con un número de clase bajo, la mayor parte del techo requiere filtros
HEPA. Para un ISO habitación Clase 5, el techo entero usualmente requiere filtración HEPA.
Idealmente, un piso rallado o perforado sirve como el escape de aire. Salas blancas farmacéuticas
típicamente tienen pisos sólidos y retornos de nivel bajos. La velocidad ampliamente aceptada es
90 fpm (0.46 m/s).
En un flujo horizontal, la pared de suministro comprende en su totalidad de filtros HEPA que
suministran aire a una velocidad de aproximadamente 90 fm (0.46 m/s) a través de toda la sección
de la habitación. El aire existe a través de la pared de retorno en el extremo opuesto de la
habitación. Este diseño remueve la contaminación generada en el espacio a una velocidad igual a
la velocidad del aire y no permite contaminación cruzada perpendicular al flujo de aire. Una limitación importante a este diseño es que el aire aguas abajo se contamina.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Espacios Limpios
02.fm Page 65 Thursday, March 3, 2016 12:27 PM
Límites de Concentración de Partículas Suspendidas en el Aire
*Sustituido Norma Federal 209CE de los Estados Unidos Clases de Partículas Suspendidas en el Aire en Salas Blancas y Zonas Limpias
Número de Partículas por Metro Cúbico por tamaño (micrómetros)
Equivalente
Clase FS
209
0.1µm
0.2µm
0.3µm
0.5µm
1µm
5µm
1
2
3
4
5
6
7
8
9
—
—
1
10
100
1.000
10.000
100.000
—
10
100
1.000
10,000
100.000
1.000.000
—
—
—
2
24
237
2,370
23.700
237,000
—
—
—
—
10
102
1.020
10.200
102.000
—
—
—
—
4
35
352
3,520
35.200
352.000
3,520.000
35.200.000
—
—
8
83
832
8.320
83.200
832.000
8.320.000
—
—
—
—
29
293
2.930
29.300
293.000
65
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 2.9 ISO Clase 7 (FS 209 Clase 10.000) Sala Blanca no Unidireccional con Elementos de
Suministro de Filtro HEPA Canalizado y ISO Clase 5 (FS 209 Clase 100) Sala Blanca Unidireccional
con HEPA Canalizado o Techo Filtro ULPA
Contaminantes de Aire y Control
Clase
ISO
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 2.12
ESPACIOS LIMPIOS
Norma ISO 14644 Sección 1*
03.fm Page 66 Thursday , March 3, 2016 12:41 PM
AGUA
Tabla 3.1 Términos de Bomba Común, Símbolos y Fórmulas
Término
Velocidad
Volumen
Velocidad de flujo
Presión
Densidad
Aceleración de Gravedad
Velocidad
Símbolo
Unidades
v
pie/s (m/s)
V
pie3 (m3)
gpm (m3/s or L/s)
Qv
p
psi (kPa)

lb/pie3 (kg/m3)
g
32.17 pie/s2 (9.807 m/s2)
n
rpm (rpm o rad)
Agua
Gravedad Específica
Cabeza
Cabeza de succión positiva neta
Eficiencia (porcentaje)
Bomba
Motor eléctrico
Variador de velocidad
Equipo (bombas de velocidad constante)
Equipo (bombas de velocidad variable)
Utilización
QD = flujo de diseño
QA = flujo actual
HD = cabeza de diseño
HA = cabeza actual
Índice de la Eficiencia del Sistema (decimal)
SG
—
H
H
pie (m)
pie (m)
p
m
v
e
e
u
hp (kW)
Potencia en el eje
Potencia de salida
Ps
Pi
hp (kW)
kW
Variable
Constante
Variable
Constante
Constante
SEI = 10–4 u
QvHSG/3960
(Qvm/101 [Qv in L/s])
100Po /p
74.6 (100) Ps /m
Leyes de Afinidad para Bombas
Gravedad
Específica (SG)
Constante
Constante
Variable
Para
Corregir
Multiplicar
por
Flujo
Velocidad Nueva
------------------------------------------Velocidad Vieja
Cabeza
Nueva 2
 Velocidad
-------------------------------------------
 Velocidad Vieja 
Potencia
Nueva 3
 Velocidad
-------------------------------------------
 Velocidad Vieja 
Flujo
Diámetro Nueva
----------------------------------------Diámetro Vieja
Diámetro
Nueva 2
 Diámetro
-----------------------------------------
 Diámetro Vieja 
Potencia
Nueva 3
 Diámetro
-----------------------------------------
 Diámetro Vieja 
Potencia
SG Nueva
-------------------------SG Vieja
66
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Constante
Velocidad
2,31 p/SG
Q H
D D
 u = 100 -----------------Q A HA
Po
Tabla 3.2
Masa de líquido
= -------------------------------------------------Masa de agua a 39°F
e = pm /100
e = 10–4pmv
Potencia de salida (bomba)
Diámetro de
Impulsor
Fórmula
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
3.
03.fm Page 67 Thursday , March 3, 2016 12:41 PM
(I-P)
 m cabeza  sp. gr.potencia de bomba, kW = L/s
-------------------------------------------------------101   p   m
(SI)
Agua
Si el sistema hidrónico tiene una curva de altura del sistema como está mostrado en la curva
A, la bomba a 1150 rpm operará en el punto 1, no en el punto 2, como se predijo solo por las ley es
de afinidad. Si el sistema hidrónico tiene una curva de altura del sistema como la curva B de esta
figura, la bomba a 1150 rpm se ejecutará a la cabeza de cierre y no entregará agua. Esto demuestra
que las ley es de afinidad deben ser utilizadas para desarrollar nuevas curvas de cabeza/capacidad
de bomba, pero no para predecir rendimiento con un sistema hidrónico particular a no ser que la
curva de altura del sistema es conocida.
67
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 3.1 Curvas de Bombas y Curvas del Sistema
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Gpm  pie cabeza  sp.gr
bomba, hp = ---------------------------------------------------------------------------------------------------------------------3960  eficiencia de bomba  eficiencia de motor
03.fm Page 68 Thursday , March 3, 2016 12:41 PM
Atención especial debe ser dada a la presión y temperatura del agua que entra en la bomba,
especialmente en torres de condensado, retornos de condensado de vapor y alimentaciones de calderos de vapor.
La presión en exceso de la requerida para prevenir que se formen bolsas de vapor es la cabeza
de succión positiva neta requerida (NPSHR). La cabeza de succión positiva neta requerida
(NPSHR) es una característica de una bomba dada y varía con el flujo y velocidad de la bomba.
Está determinado por el fabricante y está incluido en la curva de rendimiento de la bomba.
Si la presión absoluta en la boquilla de succión alcanza la presión de vapor del líquido, bolsas
de vapor se forman en los pasajes del impulsor. El colapso de las bolsas de vapor (cavitación) es
ruidoso y puede ser destructivo para el impulsor de la bomba.
La cabeza de succión positiva neta requerida (NPSHR) es principalmente importante cuando
una bomba está operando con líquidos calientes o es aplicada a un circuito que tiene una altura de
aspiración. La presión de vapor aumenta con la temperatura del agua y reduce la cabeza de succión positiva neta disponible (NPSHA). Cada bomba tiene su cabeza de succión positiva neta
requerida (NPSHR) y la instalación tiene su cabeza de succión positiva neta disponible (NPSHA),
que es la energía útil total sobre la presión de vapor en la entrada de la bomba.
NPSHA = h p + h z – h vpa – h f
(I-P)
NPSHA = p p + p z – p vpa – p f
(SI)
donde
hp (pp)
hz (pz)
Agua
= presión absoluta en superficie de líquida que entra en la bomba, ft de cabeza (Pa)
= elevación estática del líquido sobre la línea de centro de la bomba (hz es negativo
si el nivel del líquido está bajo la línea de centro de la bomba), ft (Pa)
hypa (Pypa)
= presión de vapor absoluta en temperatura de bombeo, ft (Pa)
hf (pf)
= pérdidas de cabeza y fricción en tubería de succión, ft (Pa)
Para determinar la cabeza de succión positiva neta disponible (NPSHA) en una instalación
existente, la siguiente ecuación puede ser utilizada (ver Figura 3.2):
2
NPSHA = h a + h s + V
------ – h vpa
2g
(I-P)
2
NPSHA = p a + p s + V
--------- – p vpa
2
donde
ha (pa)
hs (ps)
(SI)
Figura 3.2 Cabeza de Succión Positiva Neta Disponible [2012S, Ch 44, Fig 31]
68
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
= cabeza atmosférica para elevación de instalación, ft (Pa)
= cabeza en la brida de entrada corregida en la línea de centro de la bomba (hs
es negativa si está bajo presión atmosférica), ft (Pa)
V2/2g (V2p/2) = cabeza de velocidad en punto de medición de hso ft (Pa)

= densidad de fluido, kg/m3
Si la cabeza de succión positiva neta disponible (NPSHA) es menos que la cabeza de succión
positiva neta requerida (NPSHR) de la bomba, cavitación, ruido, bombeo inadecuado y problemas
mecánicos resultarán. Para diseño libre de problemas, la cabeza de succión positiva neta disponible (NPSHA) debe ser siempre más grande que la cabeza de succión positiva neta
requerida (NPSHR) de la bomba. En sistemas cerrados de agua caliente y fría donde la suficiente presión de llenado del sistema es ejercido en la succión de la bomba, la cabeza de succión
positiva neta requerida (NPSHR), normalmente no es un factor.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Características de Succión Positiva Neta
03.fm Page 69 Thursday , March 3, 2016 12:41 PM
Regiones de Selección de Bomba [2012S, Ch 44, Fig 33]
Agua
Figura 3.5 Construcción de Curva para Bombas Paralelas Disímiles [2012S, Ch 44, Fig 36]
69
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 3.4 Condiciones Operativas para Operación Paralela [2012S, Ch 44, Fig 35]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 3.3
03.fm Page 70 Thursday , March 3, 2016 12:41 PM
Agua
Curvas de Bomba Típicas (Curvas Varían por Fabricante) [2012S, Ch 44, Fig 11]
Curvas de Bomba Típicas (Curvas Varían por Fabricante)
[2012S, Ch 44, Fig 11]
70
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 3.6 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 3.6 (I-P)
Galón
EE.UU.
1.
1.201
.004329
7.4805
.1198
11.98
239.6
.2642
264.2
60°F
1.12
1.12
70°F
.98
.98
80°F
.86
.86
100°F
.68
.69
Pulgada
Cúbica
231.
22.741
1.
1728.
27.68
2765.

61.023

Pie
Cúbico
.13368
.1605
.000579
1.
.01602
1.602
32.04
.0353
35.314
Convert to
*
Libra
8.345
10.02
.036124
62.425
1.
100.
2000.
2.205
2204.5
Tabla 3.4 (I-P) Peso y Volumen Equivalentes
50°F
1.31
1.31
Galón
Imperial
.8327
1.
.003607
6.229
.0998
9.98
199.6
.22
220.
32°F
1.70
1.79
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
a. Volumen—relación de peso tomada para agua a la may or densidad (39.2°F)
Galón EE.UU.
Galón Imperial
Pulgada Cúbica
Pie Cúbico
Libraa
Cwt (EE.UU.)*
Ton (EE.UU.)*
Litro
Metro Cúbico
Convertir de
Viscosidad absoluta, centipois
Viscosidad cinemático,centistokes
La viscosidad del agua varía como sigue:
*
Cwt (U.S.)
.08345
.1002
–
.6243
.01
1.
20.0
.022
22.045
120°F
.56
.57
160°F
.40
.41
180°F
.35
.36
*
Ton (EE.UU)
Litro
.00418
3.785
.00502
4.546
–
.0164
.03121
28.317
.0005
.454
.05
45.36
1.
906.9
.0011
1.
1.102
1000.
140°F
.47
.45
Metro
Cúbico
.00378
.00455
–
.0283
–
.045
.907
.001
1.
212°F
.28
.29
Tabla 3.3 (I-P) Información General Sobre Agua
La gravedad específica del agua es usualmente dada como 1.0 a 60°F. Sin embargo, para algunos propósitos esta es dada como 1.0 a 39.2°F, el punto de densidad máxima.
Basada en agua a 39.2°F como 1.0, el agua a 60°F tiene una gravedad específica de 0.999. Por consiguiente, cual base es seleccionada no hace diferencia práctica.
03.fm Page 71 Thursday , March 3, 2016 12:41 PM
Agua
71
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Presión,
kPa
0.87
1.23
1.71
2.34
3.17
4.25
5.63
7.38
9.59
12.34
15.75
19.93
25.02
31.18
38.56
47.37
57.81
70.12
84.53
Temperatura,
°C
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
974.8
971.8
968.6
965.3
961.9
988.0
985.6
983.2
980.5
977.8
997.0
995.6
994.0
992.2
990.2
Densidad,
kg/m3
999.9
999.7
999.1
998.2
Calor Específico,
kJ (kg·K)
4.200
4.188
4.184
4.183
4.183
4.183
4.183
4.182
4.182
4.182
4.182
4.183
4.184
4.187
4.190
4.194
4.199
4.204
4.210
104.8
125.7
146.6
167.5
188.4
209.3
230.2
251.2
272.1
293.0
314.0
334.9
355.9
376.9
398.0
Propiedades del Agua—5°C a 95°C
Agua
Calor Total encima de 0°C,
kJ/kg
21.0
42.0
62.9
83.8
Tabla 3.3 (SI)
03.fm Page 72 Thursday , March 3, 2016 12:41 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
377.8
354.5
333.4
314.5
297.4
547.0
504.1
466.5
433.4
404.0
890.5
797.7
719.6
653.2
596.3
Viscosidad,
mPa·s
1519.1
1306.6
1138.2
1002.1
666.7
670.0
672.8
675.3
677.4
643.5
649.2
654.3
658.9
663.1
607.1
615.4
623.2
630.5
637.3
Condición Térmica,
mW/(m·K)
570.5
580.0
589.3
598.4
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
72
03.fm Page 73 Thursday , March 3, 2016 12:41 PM
Agua
Glicol,
% en Masa
10
15
20
25
30
40
50
60
Glicol Etileno
°F (°C)
26.2 (–3.2)
22.2 (–5.4)
17.9 (–7.8)
12.7 (–10.7)
6.7 (–14.1)
8.1 (–22.3)
28.9 (–33.8)
54.8 (–48.3)
Glicol Propileno
°F (°C)
26.1 (–1.3)
22.9 (–5.1)
19.2 (–7.1)
14.7 (–9.6)
9.2 (–12.7)
6.0 (–21.1)
28.3 (–33.5)
59.9 (–51.1)
Las soluciones de glicol etileno son menos viscosas que las soluciones de glicol propileno en
la misma concentración. El glicol propileno menos tóxico es preferido para aplicaciones que involucran posible contacto humano.
73
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tabla 3.5 Puntos de Congelación para Soluciones
de Glicol Etileno y Glicol Propileno
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 3.7 Flujo de Masa y Calor Específico del Agua
03.fm Page 74 Thursday , March 3, 2016 12:41 PM
Diámetro en
Pie
Pulgadas
1
0
1
2
1
4
1
6
1
8
1
10
2
0
2
2
2
4
2
6
2
8
2
10
3
0
3
2
3
4
Galones
EE.UU.
5.875
7.997
10.44
13.22
16.32
19.75
23.50
27.58
31.99
36.72
41.78
47.16
52.88
58.92
65.28
Agua
Tabla 3.6 (SI)
Diámetro en
Pie
Pulgadas
3
6
3
8
3
10
4
0
4
2
4
4
4
6
4
8
4
10
5
0
5
2
5
4
5
6
5
8
5
10
Galones
EE.UU.
71.97
78.99
86.33
94.00
102.0
110.3
119.0
127.9
137.3
146.9
156.8
167.1
177.7
188.7
199.9
Diámetro en
Pie
Pulgadas
6
0
6
6
7
0
7
6
8
0
8
6
9
0
9
6
10
0
10
6
11
0
11
6
12
0
12
6
Galones
EE.UU.
211.5
248.2
287.9
330.5
376.0
424.5
475.9
530.2
587.5
647.7
710.9
777.0
846.0
918.0
Volumen de Tanque Cilíndrico por Metro de Profundidad
Volumen, m3
7.548
8.553
9.621
10.75
11.95
13.20
14.52
15.90
17.35
18.86
20.43
22.06
23.76
25.52
27.34
Diámetro, m
3.1
303
3.5
3.7
3.9
4.1
4.3
4.5
4.7
4.9
5.1
5.3
5.5
5.7
5.9
Tabla 3.7 Cantidades para Varias Profundidades de
Tanques Cilíndricos Verticales en Posición Horizontal
%
% de
Profundidad
Capacidad
Llena
1
.20
3
.90
5
1.87
7
3.07
9
4.45
11
5.98
13
7.64
15
9.40
17
11.27
19
13.23
21
15.26
23
17.40
25
19.61
%
%
% de
% de
Profundidad
Profundidad
Capacidad
Capacidad
Llena
Llena
26
20.73
51
51.27
28
23.00
53
53.81
30
25.31
55
56.34
32
27.66
57
58.86
34
30.03
59
61.36
36
32.44
61
63.86
38
34.90
63
66.34
40
37.36
65
68.81
42
39.89
67
71.16
44
42.40
69
73.52
46
44.92
71
75.93
48
47.45
73
78.14
50
50.00
75
80.39
%
Profundidad
Llena
76
78
80
82
84
86
88
90
92
94
96
98
100
% de
Capacidad
81.50
83.68
85.77
87.76
89.68
91.50
93.20
94.80
96.26
97.55
98.66
99.50
100.0
74
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Diámetro, m
Volumen, m3
0.1
0.0079
0.3
0.0707
0.5
0.1963
0.7
0.3848
0.9
0.6362
1.1
0.9503
1.3
1.327
1.5
1.767
1.7
2.270
1.9
2.835
2.1
3.464
2.3
4.155
2.5
4.909
2.7
5.726
2.9
6.605
Volumen por metro de profundad =  (Diámetro/2) 2
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 3.6 (I-P) Volumen de Tanques Cilíndricos Verticales en Galones por
Pie de Profundidad
40
40
(15)
(16)
(20)
5/8
3/4
(100)
(125)
(150)
(200)
(250)
(300)
4
5
6
8
10
12
40
(80)
(90)
(65)
2 1/2
3
(50)
2
30
30
30
40
40
40
40
40
40
12.090
10.136
8.071
6.065
5.047
4.026
3.548
3.068
2.469
2.067
1.610
1.380
1.049
0.824
—
0.622
(307.1)
(257.5)
(205.0)
(154.1)
(128.2)
(102.3)
(90.1)
(77.9)
(62.7)
(52.5)
(40.9)
(35.0)
(26.6)
(20.9)
—
(15.8)
—
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
3 1/2
40
(40)
1 1/2
40
(25)
(32)
1
1 1/4
—
40
—
1/2
—
(10)
3/8
(mm)
Diámetro Interno
pulg.
(mm)
pulg.
Lista No.
5.96
4.19
2.66
1.50
1.04
0.661
0.514
0.384
0.249
0.174
0.106
0.0779
0.0449
0.0277
—
0.0157
—
(74.02)
(52.04)
(33.03)
(18.63)
(12.92)
(8.21)
(6.38)
(4.77)
(3.09)
(2.16)
(1.32)
(0.97)
(0.56)
(0.34)
—
(0.19)
—
(L/m)
Volumen
gal/pie
11.565
9.625
7.725
5.845
4.875
3.905
3.425
2.945
2.465
1.985
1.505
1.265
1.025
0.785
0.666
0.545
0.430
pulg.
(293.8)
(244.5)
(196.2)
(148.5)
(123.8)
(99.2)
(87.0)
(74.8)
(62.6)
(50.4)
(38.2)
(32.1)
(26.0)
(19.9)
(16.9)
(13.8)
(10.9)
(mm)
5.46
3.78
2.43
1.39
0.970
0.622
0.479
0.354
0.248
0.161
0.0924
0.0653
0.0429
0.0251
0.0181
0.0121
0.0075
gal/pie
(67.81)
(46.95)
(30.18)
(17.26)
(12.05)
(7.73)
(5.95)
(4.40)
(3.08)
(2.00)
(1.15)
(0.81)
(0.53)
(0.31)
(0.22)
(0.15)
(0.09)
(L/m)
Volumen
Tubos de Cobre Tipo Le
Diámetro Interno
Volumen de Agua en Tubos y Tuberías Estándar
Tubería de Acero Estándar
Tamaño Nominal
de Tubería
Tabla 3.8
03.fm Page 75 Thursday , March 3, 2016 12:41 PM
Agua
75
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
03.fm Page 76 Thursday , March 3, 2016 12:41 PM
Agua
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
76
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 3.8 (I-P) Pérdida por Fricción para Agua en Tubería de Cobre (Tipos K, L, M)
[2013F, Ch 22, Fig 5]
03.fm Page 77 Thursday , March 3, 2016 12:41 PM
Agua
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
77
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 3.8 (SI) Pérdida por Fricción para Agua en Tubería de Cobre (Tipos K, L, M)
[2013F, Ch 22, Fig 5]
03.fm Page 78 Thursday, March 3, 2016 2:54 PM
Agua
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
78
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 3.9 (I-P) Pérdida por Fricción para Agua en Tubería de Plástico (Lista 80)
[2013F, Ch 22, Fig 6]
03.fm Page 79 Thursday , March 3, 2016 12:41 PM
Agua
79
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Pérdida por Fricción para Agua en Tubería de Plástico (Lista 80)
[2013F, Ch 22, Fig 6]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 3.9 (SI)
03.fm Page 80 Thursday , March 3, 2016 12:41 PM
Agua
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Pérdida por Fricción para Agua en Tubería de Acero Comercial (Lista 40)
[2013F, Ch 22, Fig 4]
80
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 3.10 (I-P)
03.fm Page 81 Thursday , March 3, 2016 12:41 PM
Agua
81
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Pérdida por Fricción para Agua en Tubería de Acero Comercial (Lista 40)
[2013F, Ch 22, Fig 4]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 3.10 (SI)
03.fm Page 82 Thursday , March 3, 2016 12:41 PM
Las válvulas y accesorios causan pérdidas de presión may ores que aquellas causadas solamente por la tubería. Una formulación expresa las pérdidas como
 V
V
p = K  -----  ------ or h = K  ------
g
2
2g
2
2
(I-P)
c
2
2
V
V
p = K  ------ or h = K  ------
2
2g
(SI)
donde K = geometría – y tamaño – coeficiente de pérdida dependiente (ver las siguientes tablas).
El proy ecto de investigación de ASHRAE RP-1193 encontró los datos en las siguientes tablas
dando factores K para Lista 80 PVC 2, 4, 6 y 8 pulg. (50, 100, 150 y 200 mm) eles, reductores,
expansiones y Tes. En general, la geometría roscada PVC varió mucho más de un fabricante a otro
que lo hizo los accesorios de acero.
Cálculo de las Pérdidas de Presión
Agua
El cálculo más común de diseño de ingeniería de pérdida de flujo selecciona un tamaño de
tubería para la velocidad de flujo total deseada o caída de presión permisible.
Debido a que cualquiera de la formulación de pérdidas de accesorios requiere un diámetro
conocido, el tamaño de la tubería debe ser seleccionada antes de calcular la influencia detallada de
los accesorios. Una regla de oro utilizada frecuentemente asume que la longitud del diseño de la
tubería es 50 a 100% may or que la actual para tener en cuenta las pérdidas de accesorios. Después
que un diámetro de tubería ha sido seleccionado sobre esta base, la influencia de cada accesorio
puede ser evaluada.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
82
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Pérdidas de Accesorios y Válvulas
0.38
0.37
0.35
0.34
0.33
0.32
0.31
0.30
0.29
0.28
2.5
2.1
1.7
1.5
1.3
1.2
1.0
0.85
0.80
0.70
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
0.90
2.7
2.4
2.1
1.8
1.7
1.6
1.4
1.3
1.2
1.1
20
14
10
9
8.5
8
7
6.5
6
5.7
0.40
0.33
0.28
0.24
0.22
0.19
0.17
0.16
0.14
0.12
—
—
6.1
4.6
3.6
2.9
2.1
1.6
1.3
1.0
8.0
5.5
3.7
3.0
2.7
2.5
2.3
2.2
2.1
2.0
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Curva
Válvula de Entrada de
Codo de
Válvula de Válvula de Válvula de
Entrada
Entrada
de Retorno Línea T Rama T
Retención Boca de
45°
Globo Compuerta Ángulo
Cuadrada Proyectada
Estándar
Oscilante Campana
Tabla 3.9 Factores K: Accesorios de Tubería Roscados [2013F, Ch 22, Tbl 1]
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Fuente: Libro de Datos de Ingeniería (Instituto Hidráulico 1990)
Diámetro
Codo
Codo de
de Tubería
Estándar
Radio
Nominal,
90°
Largo 90°
Pulg. (mm)
3/8 (10)
2.5
—
1/2 (15)
2.1
—
3/4 (20)
1.7
0.92
1 (25)
1.5
0.78
1 1/4 (32)
1.3
0.65
1 1/2 (40)
1.2
0.54
2 (50)
1.0
0.42
2 1/2 (65)
0.85
0.35
3 (80)
0.80
0.31
4 (100)
0.70
0.24
03.fm Page 83 Thursday , March 3, 2016 12:41 PM
Agua
83
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Fuente: Libro de Datos de Ingeniería (Instituto Hidráulico 1990)
Válvula de
Compuerta
—
—
—
0.34
0.27
0.22
0.16
0.10
0.08
0.06
0.05
Válvula de
Globo
13
12
10
9
8
7
6.5
6
5.7
5.7
5.7
Factores K: Accesorios de Tubería Brida Soldada [2013F, Ch 22, Tbl 2]
Agua
Diámetro de
Codo de Radio
Codo
Codo de Radio
Curva
Curva
Tubería
Largo 90°
Estándar 90°
Largo 45°
de Retorno de Retorno Línea T Rama T
Nominal,
(90° Ell
(90° Ell Reg.)
(45° Ell)
Estándar Radio Largo
Pulg. (mm)
Largo)
1 (25)
0.43
0.41
0.22
0.43
0.43
0.26
1.0
1 1/4 (32)
0.41
0.37
0.22
0.41
0.38
0.25
0.95
1 1/2 (40)
0.40
0.35
0.21
0.40
0.35
0.23
0.90
2 (50)
0.38
0.30
0.20
0.38
0.30
0.20
0.84
2 1/2 (65)
0.35
0.28
0.19
0.35
0.27
0.18
0.79
3 (80)
0.34
0.25
0.18
0.34
0.25
0.17
0.76
4 (100)
0.31
0.22
0.18
0.31
0.22
0.15
0.70
6 (150)
0.29
0.18
0.17
0.29
0.18
0.12
0.62
8 (200)
0.27
0.16
0.17
0.27
0.15
0.10
0.58
10 (250)
0.25
0.14
0.16
0.25
0.14
0.09
0.53
12 (300)
0.24
0.13
0.16
0.24
0.13
0.08
0.50
Tabla 3.10
03.fm Page 84 Thursday , March 3, 2016 12:41 PM
4.8
3.7
3.0
2.5
2.3
2.2
2.1
2.1
2.1
2.1
2.1
Válvula de
Ángulo
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
Válvula de
Retención
Oscilante
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
84
03.fm Page 85 Thursday , March 3, 2016 12:41 PM
Reductor (2 por 1.5 pulgadas [50 por 40 mm]) de hilo
(4 por 3 pulgadas [100 por 80 mm]) de soldadura
(6 por 4 pulgadas [150 por 100 mm]) de soldadura
(8 por 6 pulgadas [200 por 150 mm]) de soldadura
(10 por 8 pulgadas [250 por 200 mm]) de soldadura
(12 por 10 pulgadas [300 por 250 mm]) de soldadura
(16 por 12 pulgadas [400 por 300 mm]) de soldadura
(20 por 16 pulgadas [500 por 400 mm]) de soldadura
(24 por 20 pulgadas [600 por 500 mm]) de soldadura
Expansión (1.5 por 2 pulgadas [40 by 50 mm]) de hilo
(3 por 4 pulgadas [80 by 100 mm]) de soldadura
(4 por 6 pulgadas [100 by 150 mm]) de soldadura
(6 por 8 pulgadas [150 by 200 mm]) de soldadura
(8 por 10 pulgadas [200 by 250 mm]) de soldadura
(10 por 12 pulgadas [250 by 300 mm]) de soldadura
(12 por 16 pulgadas [300 by 400 mm]) de soldadura
(16 por 20 pulgadas [400 by 500 mm]) de soldadura
(20 por 24 pulgadas [500 by 600 mm]) de soldadura
Fuente:Rahmey er (2003a)
a
Rahmey er (1999a, 2002a)
b
Investigación de ASHRAEa,b
4 fps
8 fps
12 fps
(1.2 m/s) (2.4 m/s) (3.6 m/s)
0.53
0.28
0.20
0.23
0.14
0.10
0.62
0.54
0.53
0.31
0.28
0.26
0.16
0.14
0.14
0.14
0.14
0.14
0.17
0.16
0.17
0.16
0.13
0.13
0.053
0.053
0.055
0.16
0.13
0.02
0.11
0.11
0.11
0.28
0.28
0.29
0.15
0.12
0.11
0.11
0.09
0.08
0.11
0.11
0.11
0.073
0.076
0.073
0.024
0.021
0.022
0.020
0.023
0.020
Ding et al (2005)
Tabla 3.12 Resumen de Datos de Prueba para Conectores en T [2013F, Ch 22, Tbl 5]
Soldadura en Tde 6 pulg (150 mm)
Soldadura en Tde 8 pulg (200 mm)
Soldadura en Tde 10 pulg (250 mm)
Soldadura en Tde 12 pulg (300 mm)
Soldadura en Tde 16 pulg (400 mm)
a
Rahmey er (1999b, 2002b).
b
Ding et al. (2005).
85
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Soldadura en Tde 4 pulg (100 mm)
Rama 100%
Línea 100% (flujo continuo)
Mezcla 100%
Rama 100%
Línea 100% (flujo continuo)
Mezcla 100%
Rama 100%
Línea 100% (flujo continuo)
Mezcla 100%
Rama 100%
Línea 100% (flujo continuo)
Mezcla 100%
Rama 100%
Línea 100% (flujo continuo)
Mezcla 100%
Rama 100%
Línea 100% (flujo continuo)
Mezcla 100%
Rama 100%
Línea 100% (flujo continuo)
Mezcla 100%
Agua
Hilo en Tde 2 pulg (50 mm)
Investigación de
ASHRAEa,b
4 fps
8 fps
12 fps
(1.2 m/s) (2.4 m/s) (3.6 m/s)
0.93
—
—
0.19
—
—
1.19
—
—
0.57
—
—
0.06
—
—
0.49
—
—
0.56
—
—
0.12
—
—
0.88
—
—
0.53
—
—
0.08
—
—
0.70
—
—
0.52
—
—
0.06
—
—
0.77
—
0.70
0.63
0.62
0.062
0.091
0.096
0.88
0.72
0.72
0.54
0.55
0.54
0.032
0.028
0.028
0.74
0.74
0.76
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 3.11 Sumario de Valores K para Reductores y Expansiones [2013F, Ch 22, Tbl 4]
03.fm Page 86 Thursday , March 3, 2016 12:41 PM
K
Accesorios de PVC Lista 80
Codo moldeado iny ectado,
2 pulg. (50 mm)
0.91 a 1.00
4 pulg. (100 mm)
0.86 a 0.91
6 pulg. (150 mm)
0.76 a 0.91
8 pulg. (200 mm)
0.68 a 0.87
Codo fabricado de 8 pulg, (200 mm) Tipo I, componentes
Tipo II, biselado
Reductor moldeado iny ectado de 6 por 4 pulg. (150 por 200 mm)
Tipo boquilla
Reductor moldeado iny ectado de 8 por 6 pulg. (200 por 150 mm)
Tipo boquilla
Agua
Tipo de reductor gradual
Expansión moldeada iny ectada de 4 por 6 pulg. (100 por 150 mm)
Tipo boquilla
Expansión moldeada iny ectada de 6 po 8 pulg. (150 por 200 mm)
Tipo de reductor gradual
0.073 a 0.76
0.12 a 0.59
0.49 a 0.59
0.13 a 0.63
0.48 a 0.68
0.21
0.069 a 1.19
0.069 a 1.14
0.95 a 0.96
0.94 a 0.95
0.99
86
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tipo boquilla
0.40 a 0.42
L, ft (m)
8.4 a 9.2
(2.6 a 2.8)
18.3 a 19.3
(5.6 a 5.9)
26.2 a 31.3
(8.0 a 9.5)
32.9 a 42.1
(10.0 a 12.8)
19.4 a 20.3
(5.9 a 6.2)
35.3 a 36.8
(10.8 a 11.2)
4.1 a 20.3
(1.2 a 6.2)
16.9 a 20.3
(5.2 a 6.2)
6.3 a 30.5
(1.9 a 9.3)
23.2 a 32.9
(7.1 a 10.0)
10.2
(3.1)
1.5 a 25.3
(0.46 a 7.7)
1.5 a 24.2
(0.46 a 7.4)
32.7 a 33.0
(10.0 a 10.1)
32.4 a 32.7
(9.9 a 10.0)
34.1
(10.4)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 3.13 Resumen de Prueba para Coeficientes de Pérdidas K y Longitudes de
Pérdida Equivalente [2013F, Ch 22, Tbl 6]
03.fm Page 87 Thursday , March 3, 2016 12:41 PM
Derivación
Accesorios de PVC Lista 80
K1-2
Tde derivación moldeado por iny ección de 2 pulg. (50 mm), flujo de línea 100%
0.13 a 0.26
—
0 a 0.12
0.74 a 1.02
—
0.98 a 1.39
Flujo 50/50
Flujo de rama 100%
Tde derivación moldeado por iny ección de 4 pulg. (100 mm), flujo de línea 100% 0.07 a 0.22
Flujo 50/50
Flujo de rama 100%
Flujo de rama 100%
Tde derivación fabricada de 6 pulg. (150 mm), flujo de línea 100%
Flujo 50/50
Flujo de rama 100%
Tde derivación moldeado por iny ección, de 8 pulg. (200 mm), flujo de línea
100%
Flujo 50/50
Flujo de rama 100%
Tde derivación fabricada de 8 pulg. (200 mm), flujo de línea 100%
Flujo 50/50
Flujo de rama 100%
—
0.03 a 0.13
0.74 a 0.82
—
0.97 a 1.12
Tde derivación moldeado por iny ección de 6 pulg. (150 mm), flujo de línea 100% 0.01 a 0.14
Flujo 50/50
K1-3
—
0.06 a 0.11
0.70 a 0.84
—
0.95 a 1.15
0.21 a 0.22
—
0.04 a 0.09
1.29 a 1.40
—
1.74 a 1.88
0.04 a 0.09
—
0.04 a 0.07
0.64 a 0.75
—
0.85 a 0.96
0.09 a 0.16
—
0.08 a 0.13
1.07 a 1.16
—
1.40 a 1.62
K1-2
K3-2
Accesorios PVC
Tde mezcla moldeado por iny ección de 2 pulg. (50 mm), flujo de línea 100%
Flujo 50/50
Flujo de mezcla 100%
Tde mezcla moldeado por iny ección de 4 pulg. (100 mm), flujo de línea 100%
Flujo de mezcla 100%
Tde mezcla moldado por iny ección de 6 pulg. (150 mm), flujo de línea 100%
Flujo 50/50
Flujo de mezcla 100%
Tde mezcla fabricado de 6 pulg. (150 mm), flujo de línea 100%
Flujo 50/50
Flujo de mezcla 100%
Tde mezcla moldeado por iny ección de 8 pulg.(200 mm), flujo de línea 100%
Flujo 50/50
Flujo de mezcla 100%
Tde mezcla fabricado de 8 pulg. (200 mm), flujo de línea 100%
Flujo 50/50
Flujo de mezcla 100%
0.12 a 0.25
—
1.22 a 1.19
0.89 a 1.88
—
0.89 a 1.54
0.07 a 0.18
—
1.19 a 1.88
0.98 a 1.88
—
0.88 a 1.02
0.06 a 0.14
—
1.26 a 1.80
1.02 a 1.60
—
0.90 a 1.07
0.19 a 0.21
—
2.94 a 3.32
2.57 a 3.17
—
1.72 a 1.98
0.04 to 0.09
—
1.10 to 1.60 0.96 to 1.32
—
0.81 to 0.93
0.13 to 0.70
—
2.36 to 10.62 2.02 to 2.67
—
1.34 to 1.53
Coeficientes basados en velocidad promedio de 8 fps (2.43 m/s). Gama de valores varían con los fabricantes de accesorios. Línea o flujo recto es Q2/Q1 = 100%. Flujo de rama es Q2/Q1 = 0%.
87
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Flujo 50/50
Agua
Mezcla
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 3.14 Resumen de Prueba para Coeficientes de Pérdidas K de T de PVC
[2013F, Ch 22, Tbl 7]
04.fm Page 88 Thursday, March 3, 2016 12:42 PM
VAPOR
Tabla 4.1 (I-P) Propiedades del Vapor Saturado
Entalpia, Btu/lb
0.25 pulg. Hg
0.50
1.00
2.00
2 psia
3
4
5
6
7
8
9
10
12
14
14.696
20
30
40
50
60
70
80
90
100
120
140
160
180
200
Volumen
Temperatura
Específico Vg,
t, °F
pie3/lb
40.34
58.80
79.03
101.14
126.08
141.48
152.97
162.24
170.06
176.85
182.86
188.28
193.21
201.96
209.56
212.00
227.96
250.33
267.25
281.01
292.71
302.92
312.03
320.27
327.81
341.25
353.02
363.53
373.06
381.79
2423.7
1256.4
652.3
339.2
173.7
118.7
90.63
73.52
61.98
53.64
47.34
42.40
38.42
32.40
28.04
26.80
20.09
13.75
10.50
8.515
7.175
6.206
5.472
4.896
4.432
3.728
3.220
2.834
2.532
2.228
Agua
Saturada
hf
Evaporación
hfg
Vapor
Saturado
hg
8.28
26.86
47.05
69.10
93.99
109.37
120.86
130.13
137.94
144.76
150.79
156.22
161.17
169.96
177.61
180.07
196.16
218.82
236.03
250.09
262.09
272.61
282.02
290.56
298.40
312.44
324.82
335.93
346.03
355.36
1071.1
1060.6
1049.2
1036.6
1022.2
1013.2
1006.4
1001.0
996.2
992.1
988.5
985.2
982.1
976.6
971.9
970.3
960.1
945.3
933.7
924.0
915.5
907.9
901.1
894.7
888.8
877.9
868.2
859.2
850.8
843.0
1079.4
1087.5
1096.3
1105.7
1116.2
1122.6
1127.3
1131.1
1164.2
1136.9
1139.3
1141.4
1143.3
1146.6
1149.5
1150.4
1156.3
1164.1
1169.7
1174.1
1177.6
1180.6
1183.1
1185.3
1187.2
1190.4
1193.0
1195.1
1196.9
1198.4
Fuentes;
1. Keenan, J., y F. Keyes. 1936. Propiedades Termodinámicas del Vapor. John Wiley e Hijos, Nueva York.
2 Holladay, W., y C. Otterholm.1985, Números. Altadena, CA.
88
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Vapor
Presión
p
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
4.
04.fm Page 89 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 4.1 (SI) Propiedades del Vapor Saturadoa
1
2
4
6
8
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370
380
390
400
410
420
430
440
6.98
17.51
28.98
36.18
41.53
45.83
60.09
69.13
75.89
81.35
85.95
89.96
93.51
96.71
99.63
102.32
104.81
107.13
109.32
11.37
113.32
115.17
116.93
118.62
120.23
121.78
123.27
124.71
126.09
127.43
128.73
129.99
131.21
132.39
133.54
134.66
135.76
136.82
137.86
138.88
139.87
140.84
141.79
142.72
143.63
144.52
145.39
146.25
147.09
Entalpia Especifica, kJ/kg
En Liquido
Calor Latente
En Vapor
Saturado
de Evaporacion
Saturado
hf
hfg
hg
29.3
73.5
121.4
151.5
173.9
191.8
251.5
289.3
317.7
340.6
359.9
376.8
391.7
405.2
417.5
428.8
439.3
449.2
458.4
467.5
475.4
483.2
490.7
497.9
504.7
511.3
517.6
523.7
529.6
535.4
540.9
546.2
551.5
556.5
561.4
566.2
570.9
575.5
579.9
584.3
588.5
592.7
596.8
600.8
604.7
608.5
612.3
616.0
619.6
2484.3
2459.5
2432.4
2415.3
2404.5
2392.2
2357.7
2335.4
2318.6
2304.9
2293.2
2282.9
2273.7
2265.4
2257.7
2250.6
2244.0
2237.8
2231.9
2226.3
2221.0
2215.9
2211.1
2206.4
2201.9
2197.6
2193.4
2189.3
2185.4
2181.6
2177.8
2174.2
2170.7
2167.3
2163.9
2160.6
2157.4
2154.3
2151.2
2148.2
2145.2
2142.3
2139.5
2136.7
2133.9
2131.2
2138.6
2125.9
2123.4
2513.6
2533.0
2553.9
2566.8
2576.4
2584.1
2609.1
2624.8
2636.3
2645.4
2653.1
2659.7
2665.4
2670.6
2675.2
2679.5
2683.3
2686.9
2690.3
2693.4
2696.4
2699.1
2701.8
2704.2
2706.6
2708.9
2711.0
2713.1
2715.0
2716.9
2718.7
2720.5
2722.2
2723.8
2735.4
2726.9
2728.4
2729.8
2731.1
2732.5
2733.8
2735.0
2736.3
2737.5
2738.6
2739.8
2740.9
2741.9
2743.0
Spec. Vol.
v,
m3/kg
129.205
67.010
34.805
23.742
18.104
14.673
7.648
5.228
3.992
3.239
2.731
2.364
2.087
1.869
1.694
1.549
1.428
1.325
1.237
1.159
1.091
1.031
0.977
0.929
0.886
0.846
0.810
0.777
0.747
0.719
0.693
0.669
0.646
0.625
0.606
0.587
0.570
0.554
0.539
0.524
0.510
0.497
0.485
0.473
0.462
0.452
0.442
0.432
0.423
Vapor
Temperatura
ts,
°C
89
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Presion
Absoluta
p,
kPa
04.fm Page 90 Thursday, March 3, 2016 12:42 PM
450
460
470
480
490
500
520
540
560
580
600
620
640
660
680
700
720
740
760
780
800
820
840
860
880
900
920
940
960
980
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
147.92
148.73
149.53
150.31
151.09
151.85
153.33
154.77
156.16
157.52
158.84
160.12
161.38
162.60
163.79
164.96
166.10
167.21
168.30
169.37
170.41
171.44
172.45
173.43
174.40
175.36
176.29
177.21
178.12
179.01
179.88
184.06
187.96
191.60
195.04
198.28
201.37
204.30
207.10
209.79
212.37
Vapor
Temperatura
ts,
°C
Entalpia Especifica, kJ/kg
En Liquido
Calor Latente
En Vapor
Saturado
de Evaporacion
Saturado
hf
hfg
hg
623.2
626.7
630.1
633.5
636.8
640.1
646.5
652.8
658.8
664.7
670.4
676.0
681.5
686.8
692.0
697.1
702.0
706.9
711.7
716.4
720.9
725.4
729.8
734.2
738.4
742.6
746.8
750.8
754.8
758.7
762.6
781.1
798.4
814.7
830.0
844.6
858.5
871.8
884.5
896.8
908.6
2120.8
2118.2
2115.8
2113.4
2111.0
2108.6
2104.0
2099.4
2095.0
2090.7
2086.4
2082.3
2078.2
2074.2
2070.3
2066.4
2062.7
2058.9
2055.3
2051.7
2048.2
2044.7
2041.2
2037.8
2034.5
2031.2
2028.0
2024.7
2021.6
2018.4
2015.3
2000.4
1986.2
1972.6
1959.6
1947.1
1935.1
1923.4
1912.1
1901.1
1890.4
2744.0
2745.0
2746.0
2746.9
2747.8
2748.7
2750.5
2752.2
2753.8
2755.4
2756.8
2758.3
2759.9
2761.0
2762.3
2763.5
2764.7
2765.8
2767.0
2768.0
2769.1
2770.1
2771.1
2772.0
2772.9
2773.8
2774.7
2775.6
2776.4
2777.2
2777.9
2781.5
2784.6
2787.3
2789.7
2791.8
2793.6
2795.2
2796.6
2797.8
2798.9
Spec. Vol.
v,
m3/kg
0.414
0.405
0.397
0.389
0.382
0.375
0.361
0.349
0.337
0.326
0.316
0.306
0.297
0.288
0.280
0.273
0.266
0.259
0.252
0.246
0.240
0.235
0.229
0.224
0.220
0.215
0.210
0.206
0.202
0.198
0.194
0.177
0.163
0.151
0.141
0.132
0.124
0.117
0.110
0.105
0.100
a. Reimpreso por permiso de CIBSE.
90
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Presion
Absoluta
p,
kPa
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 4.1 (SI) Propiedades del Vapor Saturadoa (Continuo)
91
1/8 psi (2 oz/in2)
Presion Saturada,
psig
3.5
12
14
16
26
31
53
66
84
100
162
194
258
310
465
550
670
800
950
1,160
1,680
2,100
2,820
3,350
5,570
7,000
10,200 12,600
16,500 19,500
Caída de presión por 100 pie de longitud
1/4 psi (4 oz/in2)
1/2 psi (8 oz/in2)
3/4 psi (12 oz/in2)
Presion Saturada,
Presion Saturada,
Presion Saturada,
psig
psig
psig
3.5
12
3.5
12
3.5
12
20
24
29
35
36
43
37
46
54
66
68
82
78
96
111
138
140
170
120
147
174
210
218
260
234
285
336
410
420
510
378
460
540
660
680
820
660
810
960
1,160
1,190
1,430
990
1,218
1,410
1,700
1,740
2,100
1,410
1,690
1,980
2,400
2,450
3,000
2,440
3,000
3,570
4,250
4,380
5,250
3,960
4,850
5,700
6,800
7,000
8,600
8,100
10,000
11,400 14,300
14,500 17,700
15,000 18,200
21,000 26,000
26,200 32,000
23,400 28,400
33,000 40,000
41,000 49,500
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Vapor
2 psi
Presion Saturada,
psig
3.5
12
60
73
114
137
232
280
360
430
710
850
1,150
1,370
1,950
2,400
2,950
3,450
4,200
4,900
7,500
8,600
11,900 14,200
24,000 29,500
42,700 52,000
67,800 81,000
1 psi
Presion Saturada,
psig
3.5
12
42
50
81
95
162
200
246
304
480
590
780
950
1,380
1,670
2,000
2,420
2,880
3,460
5,100
6,100
8,400
10,000
16,500 20,500
30,000 37,000
48,000 57,500
Notas:
1. La velocidad de flujo es en lb/h en presiones de saturación inicial de 3.5 y 12 psig. El flujo está basado en el factor de fricción Moody, donde el flujo del condensado no impide el flujo de vapor.
2. Las velocidades de flujo a 3.5 pulg. Cubren presiones saturadas de 1 a 6 psig y la velocidad a 12 psig cubre presión saturada de 8 a 16 psig con un error que no excede el 8%.
Tamaño 1/16 psi (1 oz/in2)
Tubo
Nominal Presion Saturada,
psig
pulg
3.5
12
3/4
9
11
1
17
21
1-1/4
36
45
1-1/2
56
70
2
108
134
2-1/2
174
215
3
318
380
3-1/2
462
550
4
640
800
5
1,200
1,430
6
1,920
2,300
8
3,900
4,800
10
7,200
8,800
12
11,400 13,700
Tabla 4.2 (I-P) Velocidad de Flujo de Vapor de Baja Presión en Tubería Clase 40
04.fm Page 91 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Caída de presión, Pa/m
113 Pa/m
Presion Saturada,
kPa
25
85
3.7
4.4
6.8
8.3
14
17
22
26
42
52
68
83
121
146
178
214
249
302
450
536
718
857
1 440
1 800
2 650
3 280
4 160
5 040
58 Pa/m
Presion Saturada,
kPa
25
85
2.5
3.0
4.7
5.8
9.8
12
15
19
29
36
48
58
83
102
125
153
178
213
307
378
499
611
1 020
1 260
1 890
2 290
2 950
3 580
28 Pa/m
Presion Saturada,
kPa
25
85
1.8
2.0
3.3
3.9
6.7
8.3
11
13
20
24
33
39
59
69
84
101
120
146
212
265
355
422
702
882
1 290
1 590
2 080
2 460
Presion Saturada,
kPa
25
85
4.5
5.4
8.6
10
18
21
27
33
53
64
86
103
150
180
219
265
309
378
552
662
882
1 080
1 830
2 230
3 300
4 030
5 170
6 240
170 Pa/m
Velocidad de Flujo de Vapor en Tubería Clase 40
225 Pa/m
Presion Saturada,
kPa
25
85
5.3
6.3
10
12
20
25
31
38
60
74
98
120
174
210
252
305
363
436
643
769
1 060
1 260
2 080
2 580
3 780
4 660
6 050
7 250
450 Pa/m
Presion Saturada,
kPa
25
85
7.6
9.2
14
17
29
35
45
54
89
107
145
173
246
302
372
435
529
617
945
1 080
1 500
1 790
3 020
3 720
5 380
6 550
8 540
10 200
Notas:
1. La velocidad de flujo es en g/s en presiones de saturación inicial de 25 y 85 kPa (calibre). El flujo está basado en el factor de fricción Moody, donde el flujo de condensado no impide el flujo del vapor.
2. Las velocidades de flujo a 25 kPa cubre la presión saturada de 7 a 41 kPa y las velocidades a 85 kPa cubren la presión saturada de 55 a 110 kPa con un error que no excede el 8%.
Tamaño
14 Pa/m
Tubo
Nominal, Presion Saturada,
kPa
mm
25
85
20
1.1
1.4
25
2.1
2.6
32
4.5
5.7
40
7.1
8.8
50
14
17
65
22
27
80
40
48
90
58
69
100
81
101
125
151
180
150
242
290
200
491
605
250
907
1 110
300
1 440
1 730
Tabla 4.2 (SI)
Vapor
04.fm Page 92 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
92
04.fm Page 93 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Vapor
93
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 4.1 (I-P) Diagrama de Entalpia-Presión para el Refrigerante 718 (Agua/Vapor)
[2013F, Ch 30, Fig. 19]
04.fm Page 94 Thursday, March 3, 2016 12:42 PM
94
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Vapor
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 4.1 (SI) Diagrama de Entalpia-Presión para el Refrigerante 718 (Agua/Vapor)
[2013F, Ch 30, Fig. 19]
04.fm Page 95 Thursday, March 3, 2016 12:42 PM
Tamaño
Tubo (plg.)
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
Caída de Presión por 100 pie
1/8 psi
1/4 psi
1/2 psi
3/4 psi
1 psi
Red de Distribución y Elevación 25–35 psig—Error Max. 8%
15
22
31
38
45
31
46
63
77
89
69
100
141
172
199
107
154
219
267
309
217
313
444
543
627
358
516
730
924
1,033
651
940
1,330
1,628
1,880
979
1,414
2,000
2,447
2,825
1,386
2,000
2,830
3,464
4,000
2,560
3,642
5,225
6,402
7,390
4,210
6,030
8,590
10,240
12,140
8,750
12,640
17,860
21,865
25,250
16,250
23,450
33,200
40,625
46,900
25,640
36,930
52,320
64,050
74,000
Red de Retorno y Elevación 0–4 psig—Presión de Retorno Max.
115
170
245
308
365
230
340
490
615
730
485
710
1,025
1,285
1,530
790
1,155
1,670
2,100
2,500
1,575
2,355
3,400
4,300
5,050
2,650
3,900
5,600
7,100
8,400
4,850
7,100
10,250
12,850
15,300
7,200
10,550
15,250
19,150
22,750
10,200
15,000
21,600
27,000
32,250
19,000
27,750
40,250
55,500
60,000
31,000
45,500
65,500
83,000
2 psi
63
125
281
437
886
1,460
2,660
4,000
5,660
10,460
17,180
35,100
66,350
104,500
98,000
Vapor
6
Capacidades de Tuberías de Vapor de Presión Media (30 psig)
Libras por Hora
95
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 4.3 (I-P)
04.fm Page 96 Thursday, March 3, 2016 12:42 PM
Capacity, kg/h
Tamaño de
Tubo Nominal,
mm
Sistema de Dos Tubos
Flujo de Condensado
Contra Vapor
Suministros
de Elevación
Alimentacion
Sistema de un Tubo
Valvulas de
Readiador y
Radiador y
Coneciones
Elevación
Verticales
E
Fc
3
3
3
7
7
10
7
19
10
Vertical
Horizontal
A
20
25
32
40
50
Ba
4
6
14
22
44
Cc
3
6
12
19
42
Db
3
5
9
17
33
65
80
90
100
125
72
128
176
232
476
60
91
131
193
357
53
91
130
172
-
-
19
29
54
84
126
150
200
250
300
400
816
1700
3180
5220
9980
635
1360
2590
4310
8620
-
-
247
-
Vapor
96
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota: Vapor a una presión promedio de 7 kPa encima de la atmosférica es utilizado como una base de calcular las
capacidades.
a No utilice la Columna B para caídas de presión menores de 13 Pa/m de marcha equivalente
b No utilice la Columna D para caídas de presión menores de 9 Pa/m de marcha equivalente, excepto en tamaños de
80 mm y más.
c Tono de descentramiento horizontales para bandas y radiadores no deben ser menores de 20 mm/m. Cuando este
tono no puede obtenerse, descentramientos de más de 2.5 mm en longitud debe ser un tamaño de tubería más
grande que del que se pide en esta tabla.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 4.3 (SI) Capacidades de Tubería de Vapor para Sistema de Baja Presión
04.fm Page 97 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 4.4 (I-P) Capacidades de Tubería de Vapor de Presión Alta (150 psig)
Libras Por Hora
Tamaño
Tubo
(plg.)
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
8
10
12
1/4 psi
1/2 psi
3/4 psi
1 psi
2 psi
5 psi
6 psi
420
790
1,720
2,600
4,820
7,600
13,500
20,000
28,000
47,500
80,000
170,000
300,000
470,000
Vapor
Red de Distribución y Elevación 130–180 psig—Error Max 8%
29
41
58
82
116
184
300
58
82
117
165
233
369
550
130
185
262
370
523
827
1,230
203
287
407
575
813
1,230
1,730
412
583
825
1,167
1,650
2,000
3,410
683
959
1,359
1,920
2,430
3,300
5,200
1,237
1,750
2,476
3,500
4,210
6,000
9,400
1,855
2,626
3,715
5,250
6,020
8,500
13,100
2,625
3,718
5,260
7,430
8,400
12,300
19,200
4,858
6,875
9,725
13,750
15,000
21,200
33,100
7,960
11,275
15,950
22,550
25,200
36,500
56,500
16,590
23,475
33,200
46,950
50,000
70,200 120,000
30,820
43,430
61,700
77,250
90,000 130,000 210,000
48,600
68,750
97,250 123,000 155,000 200,000 320,000
Red de Retorno y Elevación 1–20 psig—Presión de Retorno Max
156
232
360
465
560
890
313
462
690
910
1,120
1,780
650
960
1,500
1,950
2,330
3,700
1,070
1,580
2,460
3,160
3,800
6,100
2,160
3,300
4,950
6,400
7,700
12,300
3,600
5,350
8,200
10,700
12,800
20,400
6,500
9,600
15,000
19,500
23,300
37,200
9,600
14,400
22,300
28,700
34,500
55,000
13,700
20,500
31,600
40,500
49,200
78,500
25,600
38,100
58,500
76,000
91,500 146,000
42,000
62,500
96,000 125,000 150,000 238,000
97
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
Caída de Presión por 100 pie
1/8 psi
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
6
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
5
Tamaño
de Tubo
pulg.
1/32 psi (1/2 oz)
Hum Seco
Vac.
125
62
213
130
338
206
700
470
1,180
760
1,880 1,460
2,750 1,970
3,880 2,930
48
113
248
375
750
-
1/24 psi (2/3 oz)
Hum Seco
Vac.
42
145
71
143
248
149
244
393
236
388
810
535
815
1,580
868
1,360
2,130 1,560 2,180
3,300 2,200 3,250
4,580 3,350 4,500
7,880
12,600
48
143
113
244
248
388
375
815
750
1,360
2,180
3,250
4,480
7,880
12,600
Pressure Drop per 100 ft
1/6 psi (1 oz)
1/8 psi (2 oz)
Hum Seco
Vac. Hum Seco
Vac.
100
142
175
80
175
250
103
249
300
168
300
425
217
426
475
265
475
675
340
674
1,000
575
1,000 1,400
740
1,420
1,680
950
1,680 2,350 1,230 2,380
2,680 1,750 2,680 3,750 2,250 3,800
4,000 2,500 4,000 5,500 3,230 5,680
5,500 3,750 5,500 7,750 4,830 7,810
9,680
13,700
15,500
22,000
48
175
48
249
113
300
113
426
248
475
248
674
375
1,000
375
1,420
750
1,680
750
2,380
2,680
3,800
4,000
5,680
5,500
7,810
9,680
13,700
15,500
22,000
1/4 psi (4 oz)
Seco
Vac.
200
115
350
241
600
378
950
825
2,000
1,360 3,350
2,500 5,350
3,580 8,000
5,380 11,000
19,400
31,000
48
350
113
600
248
950
375
2,000
750
3,350
5,350
8,000
11,000
19,400
31,000
Hum
350
600
950
2,000
3,350
5,350
8,000
11,000
-
1/2 psi (8 oz)
Seco
Vac.
283
494
848
1,340
2,830
4,730
7,560
11,300
15,500
27,300
43,800
494
848
1,340
2,830
4,730
7,560
11,300
15,500
27,300
43,800
Hum
-
Tabla 4.5 (I-P) Tubería Principal de Retorno y Capacidades de Tubos de Subida para Sistemas de Vapor de Baja Presión—Libras por Hora
Vapor
04.fm Page 98 Thursday, March 3, 2016 12:42 PM
Tubería Principal de Retorno
Elevador
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
98
Elevador
Tubería Principal de Retorno
65
80
70
100
125
65
80
90
100
125
150
20
25
32
40
50
Tamaño
de Tubo,
mm
G
20
25
32
40
50
28
59
93
213
57
97
153
318
22
51
112
170
340
345
662
894
1330
I
H
535
853
1250
1760
Seco
7 Pa/m
J
Vac.
717
966
1500
2080
66
112
178
367
K
Hum
22
51
112
170
340
394
708
998
1520
32
68
107
243
L
Seco
9 Pa/m
989
1470
2030
3570
5720
616
989
1400
2040
3570
5720
65
111
176
370
616
M
19
65
111
176
370
Vac.
762
1220
1810
2490
79
136
215
454
N
Hum
22
51
112
170
340
431
794
1130
1700
36
76
120
261
O
Seco
14 Pa/m
1220
1810
2490
4390
7030
762
1220
1810
2490
4390
7030
79
136
215
454
762
P
45
79
136
215
454
Vac.
1070
1700
2490
3520
113
193
306
635
Q
Hum
22
51
112
170
340
558
1020
1470
2190
47
98
154
336
R
Seco
28 Pa/m
1720
2580
3540
6210
9980
1080
1720
2580
3540
6210
9980
113
193
306
644
1080
S
64
113
193
306
644
Vac.
1520
2430
3630
4990
159
272
431
907
T
Hum
22
51
112
170
340
617
1130
1620
2440
52
109
171
374
U
Seco
57 Pa/m
2430
3630
4990
8800
14100
1520
2430
3630
4990
8800
14100
159
272
431
907
1520
V
91
159
272
431
907
Vac.
W
Hum
X
Seco
113 Pa/m
3430
5130
7030
12400
19900
2150
3430
5130
7030
12400
19900
224
385
608
1280
2150
Y
128
224
385
608
1280
Vac.
Tubería Principal de Retorno y Capacidades de Tubos de Subida para Sistemas de Vapor de Baja Presión—Libras por Hora
Hum
Tabla 4.5 (SI)
04.fm Page 99 Thursday, March 3, 2016 12:42 PM
Vapor
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
99
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Tubo
Diametro
Exterior,
pulg.
0.540
0.675
0.840
1.050
1.315
1.660
1.900
2.375
2.875
1/4
3/8
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
TUBERIA
Tamaño
Nominal,
pulg.
5.
Tuberia
0.203
0.276
40 ST
0.218
80 XS
80 XS
0.154
0.200
80 XS
40 ST
0.145
0.191
40 ST
0.140
40 ST
0.179
80 XS
80 XS
0.133
0.154
40 ST
80 XS
0.147
0.113
80 XS
40 ST
0.109
0.126
40 ST
0.091
40 ST
0.119
80 XS
80 XS
0.088
Espesor de
Pared t,
pulg.
40 ST
Numero
de Lista
o Pesoa
2.323
2.469
1.939
2.067
1.500
1.610
1.278
1.380
0.957
1.049
0.742
0.824
0.546
0.622
0.423
0.493
0.302
0.364
Diametro
Interior d,
pulg.
0.194
0.275
0.251
0.361
0.335
0.421
0.393
0.541
0.508
0.646
0.608
0.344
0.344
0.435
0.435
0.497
0.497
0.622
0.622
0.753
0.753
0.163
0.220
0.275
0.111
0.177
0.143
0.129
0.177
0.216
0.079
0.141
0.220
0.095
0.141
0.275
Interior,
pie2/pie
Exterior,
pie2/pie
Area de Superficie
2.25
1.70
1.48
1.07
1.068
0.799
0.881
0.669
0.639
0.494
0.433
0.333
0.320
0.250
0.217
0.167
0.157
0.125
Area Metalica,
pulg2
4.24
4.79
2.95
3.36
1.77
2.04
1.28
1.50
0.719
0.864
0.432
0.533
0.234
0.304
0.141
0.191
0.072
0.104
Area Flujo,
pulg2
Sección Transversal
Tabla 5.1 (I-P) Datos de Tubos de Acero
05.fm Page 100 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
7.66
5.79
5.02
3.65
3.63
2.72
2.99
2.27
2.17
1.68
1.47
1.13
1.087
0.850
0.738
0.567
0.535
0.424
Tubo,
lb/pie
Peso
1.83
2.07
1.28
1.45
0.765
0.881
0.555
0.647
0.311
0.374
0.187
0.231
0.101
0.131
0.061
0.083
0.031
0.045
Agua,
lb/pie
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
Proceso
Manufactura
W
W
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
Tipo de
Juntab
c
Presión de Trabajoc
ASTM A53 B a 400°F
835
533
551
230
576
231
594
229
642
226
681
217
753
214
820
203
871
188
psig
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
100
101
3.500
4.500
6.625
8.625
10.75
12.75
4
6
8
10
12
11.938
0.406
0.500
0.687
40
XS
80
11.376
11.750
12.000
9.564
12.090
0.375
0.593
80
9.750
ST
0.500
XS
10.020
10.136
0.330
0.365
7.625
7.981
8.071
5.761
6.065
3.826
4.026
2.900
3.068
Diametro
Interior d,
pulg.
30
0.307
0.500
80 XS
30
0.322
40 ST
0.277
30
40 ST
0.280
0.432
40 ST
80 XS
0.237
0.337
40 ST
0.300
80 XS
80 XS
0.216
Espesor de
Pared t,
pulg.
40 ST
Tubo
Numero
Diametro
de Lista
Exterior,
o Pesoa
pulg.
3.338
3.338
3.338
3.338
3.338
2.814
2.814
2.814
2.814
2.258
2.258
2.258
1.734
1.734
1.178
1.178
0.916
0.916
Exterior,
pie2/pie
2.978
3.076
3.125
3.141
3.165
2.504
2.552
2.623
2.654
1.996
2.089
2.113
1.508
1.588
1.002
1.054
0.759
0.803
Interior,
pie2/pie
Area de Superficie
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tuberia
3
Tamaño
Nominal,
pulg.
26.03
19.24
15.74
14.58
12.88
18.92
16.10
11.91
10.07
12.76
8.40
7.26
8.40
5.58
4.41
3.17
3.02
2.23
Area Metalica,
pulg2
101.6
108.4
111.9
113.1
114.8
71.84
74.66
78.85
80.69
45.66
50.03
51.16
26.07
28.89
11.50
12.73
6.60
7.39
Area Flujo,
pulg2
Sección Transversal
Tabla 5.1 (I-P) Datos de Tubos de Acero (Continuo)
05.fm Page 101 Thursday, March 3, 2016 12:42 PM
88.44
65.37
53.48
49.52
43.74
64.28
54.69
40.45
34.21
43.35
28.53
24.68
28.55
18.96
14.97
10.78
10.25
7.57
Tubo,
lb/pie
Peso
43.98
46.92
48.44
48.94
49.68
31.09
32.31
34.12
34.92
19.76
21.65
22.14
11.28
12.50
4.98
5.51
2.86
3.20
Agua,
lb/pie
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
CW
CW
CW
CW
Proceso
Manufactura
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Tipo de
Juntab
Presión de trabajoc
ASTM A53 B a 400°F
1076
748
583
528
449
1081
887
606
485
1106
643
526
1209
696
695
430
767
482
psig
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
16.00
18.00
20.00
16
18
20
0.375
0.593
40
0.562
40
0.500
0.500
XS
20 ST
0.437
30
30 XS
0.375
ST
0.375
0.750
80
0.500
0.500
XS
30 ST
0.437
40
40 XS
0.375
30 ST
Espesor de
Pared t,
pulg.
18.814
19.000
19.250
16.876
17.000
17.126
17.250
15.000
15.250
12.500
13.000
13.126
13.250
Diametro
Interior d,
pulg.
5.039
4.925
5.236
4.418
4.712
4.974
4.450
4.712
5.236
4.483
4.712
5.236
4.516
4.712
3.272
3.665
3.992
3.403
3.665
3.927
3.436
3.665
4.189
3.469
3.665
4.189
Interior,
pie2/pie
Exterior,
pie2/pie
Area de Superficie
36.15
30.63
23.12
30.79
27.49
24.11
20.76
24.35
18.41
31.22
21.21
18.62
16.05
Area Metalica,
pulg2
122.82
278.0
Peso
120.30
122.69
125.94
96.80
98.22
99.68
101.13
76.47
79.04
53.11
57.44
58.56
59.67
Agua,
lb/pie
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
Proceso
Manufactura
W
W
W
W
W
W
W
W
W
W
W
W
W
Tipo de
Juntab
Presión de trabajoc
ASTM A53 B a 400°F
581
477
337
607
530
451
374
596
421
1081
681
580
481
psig
CW) a través de 4 pulgadas y soldadura de resistencia eléctrica (ERW) de allí
en adelante. La tolerancia A se ha tomado como (1) 12.5% de t por tolerancia de laminador en el espesor de la pared del tubo, más
(2) Una tolerancia de corrosión arbitraria de 0.025 pulg. para tamaños de tubos a través de NPS 2 Y 0.065 pulg. de NPS 2 ½ a través de 20, más
(3) Un hilo que corta tolerancia para tamaños a través de NPS 2.
Debido a que el espesor de la pared del tubo de la tubería estándar roscada es muy pequeño después de deducir la tolerancia A, la fuerza mecánica de la tubería se deteriora. Es una buena práctica limitar el
peso estándar de la presión del tubo roscado a 90 psig para vapor y 125 psig para agua.
104.05
78.54
104.59
93.38
81.91
70.54
82.71
62.53
106.05
72.04
63.25
54.53
Tubo,
lb/pie
283.5
291.0
223.7
227.0
230.3
233.7
176.7
182.6
122.7
132.7
135.3
137.9
Area Flujo,
pulg2
Sección Transversal
Tabla 5.1 (I-P) Datos de Tubos de Acero (Continuo)
a Los números son números programados por ASME Norma B36, 10 M, ST = Peso Estándar, XS =Extrafuerte
b T = Hilo, W = Soldadura
c Presiones de trabajo fueron calculadas por ASME B31.9 utilizando tubos de horno de soldadura a tope (soldadura continua
14.00
Tubo
Numero
Diametro
de Lista
Exterior,
o Pesoa
pulg.
14
Tamaño
Nominal,
pulg.
Tuberia
05.fm Page 102 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
102
Tamaño
Nominal,
mm
8
10
15
20
25
32
40
50
65
Tamaño
nominal
E.U.,
pulg.
1/4
3/8
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
7.01
80 XS
5.54
5.16
40 ST
80 XS
5.08
3.91
40 ST
80 XS
4.85
3.68
80 XS
40 ST
3.56
4.55
40 ST
3.38
40 ST
80 XS
2.87
3.91
40 ST
80 XS
2.77
3.73
40 ST
80 XS
2.31
3.20
40 ST
80 XS
2.24
3.02
40 ST
Espesor de
Pared t,
mm
80 XS
Listaa
59.00
62.71
49.25
52.50
38.10
40.89
32.46
35.05
24.31
26.64
18.85
20.93
13.87
15.80
10.74
12.52
7.67
9.25
Diametro
Interior
d,
mm
0.229
0.229
0.190
0.190
0.152
0.152
0.132
0.132
0.105
0.105
0.084
0.084
0.067
0.067
0.054
0.054
0.043
0.043
Exterior,
m2/m
0.185
0.197
0.155
0.165
0.120
0.128
0.102
0.110
0.076
0.084
0.059
0.066
0.044
0.050
0.034
0.039
0.024
0.029
Inteior,
m2/m
1 454
1 099
953
690.3
689.0
515.5
568.7
431.3
412.1
318.6
279.7
214.6
206.5
161.5
140.2
107.7
101.5
80.6
Area Metalica,
mm2
2 734
3 089
1 905
2 165
1 140
1 313
827.6
965.0
464.1
557.6
279.0
344.0
151.1
196.0
90.7
123.2
46.2
67.1
Area Flujo,
mm2
Sección Transversal
Datos de Tubos de Acero
Area de Superficie
Tabla 5.1 (SI)
05.fm Page 103 Thursday, March 3, 2016 12:42 PM
Tuberia
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
103
11.40
8.62
7.47
5.43
5.40
4.05
4.45
3.38
3.23
2.50
2.19
1.68
1.618
1.265
1.098
0.844
0.796
0.631
Tubo,
kg/m
2.734
3.089
1.905
2.165
1.140
1.313
0.828
0.965
0.464
0.558
0.279
0.344
0.151
0.196
0.091
0.123
0.046
0.067
Agua,
kg/m
Masa
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
Proceso
Manufactura
W
W
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
5757
3675
3799
1586
3972
1593
4096
1579
4427
1558
4695
1496
5192
1476
5654
1400
6006
1296
Tipo de
kPa
Juntab (Calibre)
Presión de trabajoc
ASTM A53 B a 200°C
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Tamaño
Nominal,
mm
80
100
150
200
250
300
Tamaño
Nominal
E.U.,
pulg.
3
4
6
8
10
12
Tuberia
12.70
15.06
XS
80
9.53
10.31
12.70
17.45
ST
40
XS
80
8.38
9.27
30
7.80
12.70
80 XS
30
8.18
40 ST
7.04
30
40 ST
7.11
10.97
40 ST
80 XS
6.02
8.56
40 ST
80 XS
5.49
7.62
40 ST
Espesor de
Pared t,
mm
80 XS
Listaa
289.0
298.5
303.2
304.8
307.1
242.9
247.7
254.5
257.5
193.7
202.7
205.0
146.33
154.05
97.18
102.26
73.66
77.93
Diametro
Interior
d,
mm
0.484
0.460
0.644
0.637
0.608
0.809
0.800
0.778
0.763
0.965
0.958
0.953
0.938
0.908
0.529
0.529
0.688
0.688
0.688
0.858
0.858
0.858
0.858
1.017
1.017
1.017
1.017
1.017
0.321
0.305
0.359
0.359
0.245
0.231
0.279
0.279
Inteior,
m2/m
Exterior,
m2/m
Area de Superficie
16 797
12 414
10 158
9 406
8 307
12 208
10 388
7 683
6 498
8 234
5 419
4 687
5 423
3 601
2 844
2 048
1 946
1 438
Area Metalica,
mm2
65 550
69 940
72 190
72 970
74 060
46 350
48 170
50 870
52 060
29 460
32 280
33 000
16 817
18 639
7 417
8 213
4 261
4 769
Area Flujo,
mm2
Sección Transversal
65.57
69.96
72.21
72.97
74.06
46.35
48.17
50.87
52.06
29.46
32.28
33.01
16.82
18.64
7.417
8.213
4.261
4.769
Agua,
kg/m
Masa
131.62
97.28
79.59
73.70
65.09
95.66
81.39
60.20
50.91
64.51
42.46
36.73
42.49
28.22
22.28
16.04
15.25
11.27
Tubo,
kg/m
Tabla 5.1 (SI) Datos de Tubos de Acero (Continuo)
05.fm Page 104 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
CW
CW
CW
CW
Proceso
Manufactura
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
7419
5157
4020
3641
3096
7453
6116
4178
3344
7626
4433
3627
8336
4799
4792
2965
5288
3323
Tipo de
kPa
Juntab (Calibre)
Presión de Trabajoc
ASTM A53 B a 200°C
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
104
350
400
450
500
14
16
18
20
12.70
15.06
40
14.27
40
30 XS
12.70
XS
9.53
11.10
30
20 ST
9.53
12.70
ST
40 XS
19.05
80
9.53
12.70
XS
30 ST
9.53
11.10
40
Espesor de
Pared t,
mm
30 ST
Listaa
477.9
482.6
489.0
428.7
431.8
435.0
438.2
381.0
387.4
317.5
330.2
333.4
336.6
Diametro
Interior
d,
mm
1.596
1.596
1.596
1.436
1.436
1.436
1.436
1.277
1.277
1.117
1.117
1.117
1.117
Exterior,
m2/m
1.501
1.516
1.536
1.347
1.357
1.367
1.376
1.197
1.217
0.997
1.037
1.047
1.057
Inteior,
m2/m
Area de Superficie
23 325
19 762
14 916
19 863
17 735
15 556
13 396
15 708
11 876
20 142
13 681
12 013
10 356
Area Metalica,
mm2
179 400
182 900
187 700
144 300
146 450
148 600
150 800
114 000
117 800
79 160
85 610
87 290
88 970
Area Flujo,
mm2
Sección Transversal
182.78
154.85
116.88
155.65
138.97
121.90
104.98
123.09
93.06
157.82
107.21
94.13
81.15
Tubo,
kg/m
179.4
182.9
187.4
144.3
146.4
148.6
150.8
114.0
117.8
79.17
85.63
87.30
88.96
Agua,
kg/m
Masa
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
ERW
Proceso
Manufactura
W
W
W
W
W
W
W
W
W
W
W
W
W
4006
3289
2324
4185
3654
3110
2579
4109
2903
7453
4695
3999
3316
Tipo de
kPa
Juntab (Calibre)
Presión de trabajoc
ASTM A53 B a 200°C
a Los números son números programados por ASME Norma B36, 10 M, ST = Peso Estándar, XS =Extrafuerte
b T = Hilo, W = Soldadura
c Las presiones de trabajo fueron calculadas por ASME B31.9 utilizando tubos de horno de soldadura a tope (soldadura continua CW) a través de 4 pulgadas y soldadura de resistencia eléctrica (ERW) de
allí en adelante. La tolerancia A se ha tomado como (1) 12.5% de t por tolerancia de laminador en el espesor de la pared del tubo, más
(2) Una tolerancia de corrosión arbitraria de 0.64 mm para tamaños de tubos a través de NPS 2 y 1.65 mm de NPS 2 ½ a través de 20, más
(3) Un hilo que corta tolerancia para tamaños a través de NPS 2.
Debido a que el espesor de la pared del tubo de la tubería estándar roscada es muy pequeño después de deducir la tolerancia A, la fuerza mecánica de la tubería se deteriora. Es una buena práctica limitar la
presión del tubo roscado estándar a 620 kPa (calibre) para vapor y 860 kPa (calibre) para agua.
Tamaño
Nominal,
mm
Tamaño
Nominal
E.U.,
pulg.
Tabla 5.1 (SI) Datos de Tubos de Acero (Continuo)
05.fm Page 105 Thursday, March 3, 2016 12:42 PM
Tuberia
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
105
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
1 1/2
1 1/4
1
3/4
5/8
1/2
3/8
1/4
K
L
K
L
M
K
L
M
K
L
K
L
M
K
L
M
K
L
M
DWV
K
L
M
DWV
0.035
0.030
0.049
0.035
0.025
0.049
0.040
0.028
0.049
0.042
0.065
0.045
0.032
0.065
0.050
0.035
0.065
0.055
0.042
0.040
0.072
0.060
0.049
0.042
Diametro
Espesor de
Nominal, Tipo
Pared t,
pulg.
pulg.
Tuberia
0.375
0.375
0.500
0.500
0.500
0.625
0.625
0.625
0.750
0.750
0.875
0.875
0.875
1.125
1.125
1.125
1.375
1.375
1.375
1.375
1.625
1.625
1.625
1.625
Exterior
D, pulg.
0.305
0.315
0.402
0.430
0.450
0.527
0.545
0.569
0.652
0.666
0.745
0.785
0.811
0.995
1.025
1.055
1.245
1.265
1.291
1.295
1.481
1.505
1.527
1.541
Interior
d, pulg.
Diametro
Interior,
pie2/pie
0.080
0.082
0.105
0.113
0.118
0.138
0.143
0.149
0.171
0.174
0.195
0.206
0.212
0.260
0.268
0.276
0.326
0.331
0.338
0.339
0.388
0.394
0.400
0.403
Exterior
pie2/pie
0.098
0.098
0.131
0.131
0.131
0.164
0.164
0.164
0.196
0.196
0.229
0.229
0.229
0.295
0.295
0.295
0.360
0.360
0.360
0.360
0.425
0.425
0.425
0.425
Area de Superficie
Area
Metalica,
pulg2
0.037
0.033
0.069
0.051
0.037
0.089
0.074
0.053
0.108
0.093
0.165
0.117
0.085
0.216
0.169
0.120
0.268
0.228
0.176
0.168
0.351
0.295
0.243
0.209
Area de
Flujo,
pulg2
0.073
0.078
0.127
0.145
0.159
0.218
0.233
0.254
0.334
0.348
0.436
0.484
0.517
0.778
0.825
0.874
1.217
1.257
1.309
1.317
1.723
1.779
1.831
1.865
Sección Transversal
Tabla 5.2 (I-P) Datos de Tubos de Cobre
05.fm Page 106 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
0.145
0.126
0.269
0.198
0.145
0.344
0.285
0.203
0.418
0.362
0.641
0.455
0.328
0.839
0.654
0.464
1.037
0.884
0.682
0.650
1.361
1.143
0.940
0.809
Tubo,
lb/pie
Peso
0.032
0.034
0.055
0.063
0.069
0.094
0.101
0.110
0.144
0.151
0.189
0.209
0.224
0.336
0.357
0.378
0.527
0.544
0.566
0.570
0.745
0.770
0.792
0.807
Agua,
lb/pie
851
730
894
638
456
715
584
409
596
511
677
469
334
527
405
284
431
365
279
265
404
337
275
236
Cocido,
psig
1596
1368
1676
1197
855
1341
1094
766
1117
958
1270
879
625
988
760
532
808
684
522
497
758
631
516
442
Estirado,
psig
Presión de Trabajoa,b,c
ASTM B88 a 250°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
106
107
5
4
3 1/2
3
2 1/2
K
L
M
DWV
K
L
M
K
L
M
DWV
K
L
M
K
L
M
DWV
K
L
M
DWV
0.083
0.070
0.058
0.042
0.095
0.080
0.065
0.109
0.090
0.072
0.045
0.120
0.100
0.083
0.134
0.110
0.095
0.058
0.160
0.125
0.109
0.072
2.125
2.125
2.125
2.125
2.625
2.625
2.625
3.125
3.125
3.125
3.125
3.625
3.625
3.625
4.125
4.125
4.125
4.125
5.125
5.125
5.125
5.125
Exterior
D, pulg.
1.959
1.985
2.009
2.041
2.435
2.465
2.495
2.907
2.945
2.981
3.035
3.385
3.425
3.459
3.857
3.905
3.935
4.009
4.805
4.875
4.907
4.981
Interior
d, pulg.
Diametro
0.556
0.556
0.556
0.556
0.687
0.687
0.687
0.818
0.818
0.818
0.818
0.949
0.949
0.949
1.080
1.080
1.080
1.080
1.342
1.342
1.342
1.342
Exterior
pie2/pie
0.513
0.520
0.526
0.534
0.637
0.645
0.653
0.761
0.771
0.780
0.795
0.886
0.897
0.906
1.010
1.022
1.030
1.050
1.258
1.276
1.285
1.304
Interior,
pie2/pie
Area de Superficie
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tuberia
2
Diametro
Espesor de
Nominal, Tipo
Pared t,
pulg.
pulg.
Area
Metalica,
pulg2
0.532
0.452
0.377
0.275
0.755
0.640
0.523
1.033
0.858
0.691
0.435
1.321
1.107
0.924
1.680
1.387
1.203
0.741
2.496
1.963
1.718
1.143
Area de
Flujo,
pulg2
3.014
3.095
3.170
3.272
4.657
4.772
4.889
6.637
6.812
6.979
7.234
8.999
9.213
9.397
11.684
11.977
12.161
12.623
18.133
18.665
18.911
19.486
Sección Transversal
Tabla 5.2 (I-P) Datos de Tubos de Cobre (Continuo)
05.fm Page 107 Thursday, March 3, 2016 12:42 PM
2.063
1.751
1.459
1.065
2.926
2.479
2.026
4.002
3.325
2.676
1.687
5.120
4.291
3.579
6.510
5.377
4.661
2.872
9.671
7.609
6.656
4.429
Tubo,
lb/pie
Peso
1.304
1.339
1.372
1.416
2.015
2.065
2.116
2.872
2.947
3.020
3.130
3.894
3.987
4.066
5.056
5.182
5.262
5.462
7.846
8.077
8.183
8.432
Agua,
lb/pie
356
300
249
180
330
278
226
318
263
210
131
302
252
209
296
243
210
128
285
222
194
128
Cocido,
psig
668
573
467
338
619
521
423
596
492
394
246
566
472
392
555
456
394
240
534
417
364
240
Estirado,
psig
Presión de Trabajoa,b,c
ASTM B88 a 250°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
c
a
b
K
L
M
DWV
K
L
M
DWV
K
L
M
K
L
M
0.192
0.140
0.122
0.083
0.271
0.200
0.170
0.109
0.338
0.250
0.212
0.405
0.280
0.254
6.125
6.125
6.125
6.125
8.125
8.125
8.125
8.125
10.125
10.125
10.125
12.125
12.125
12.125
Exterior
D, pulg.
5.741
5.845
5.881
5.959
7.583
7.725
7.785
7.907
9.449
9.625
9.701
11.315
11.565
11.617
Interior
d, pulg.
Diametro
Interior,
pie2/pie
1.503
1.530
1.540
1.560
1.985
2.022
2.038
2.070
2.474
2.520
2.540
2.962
3.028
3.041
Exterior
pie2/pie
1.603
1.603
1.603
1.603
2.127
2.127
2.127
2.127
2.651
2.651
2.651
3.174
3.174
3.174
Area de Superficie
Area
Metalica,
pulg2
3.579
2.632
2.301
1.575
6.687
4.979
4.249
2.745
10.392
7.756
6.602
14.912
10.419
9.473
Area de
Flujo,
pulg2
25.886
26.832
27.164
27.889
45.162
46.869
47.600
49.104
70.123
72.760
73.913
100.554
105.046
105.993
Sección Transversal
Tabla 5.2 (I-P) Datos de Tubos de Cobre (Continuo)
13.867
10.200
8.916
6.105
25.911
19.295
16.463
10.637
40.271
30.054
25.584
57.784
40.375
36.706
Tubo,
lb/pie
Peso
11.201
11.610
11.754
12.068
19.542
20.280
20.597
21.247
30.342
31.483
31.982
43.510
45.454
45.863
Agua,
lb/pie
286
208
182
124
304
224
191
122
304
225
191
305
211
191
Cocido,
psig
536
391
341
232
570
421
358
229
571
422
358
571
395
358
Estirado,
psig
Presión de Trabajoa,b,c
ASTM B88 a 250°F
Cuando se utilizan accesorios soldados o de soldadura fuerte, la junta determina la presión límite.
Las presiones de trabajo fueron calculadas utilizando tensiones admisibles de la Norma ASME B3 1.9. Un 5% de tolerancia de laminador ha sido utilizado en el espesor de la pared. Las capacidades más
altas de los tubos pueden ser calculadas utilizando las tensiones admisibles para temperaturas más bajas.
Si los accesorios soldados o de soldadura fuerte son utilizados en tubos estirados en frio, utilice las capacidades de recocido. Presiones admisibles de tubo completo pueden utilizarse con accesorios de
tipo de compresión o con flama nominal adecuada.
12
10
8
6
Diametro
Espesor de
Nominal, Tipo
Pared t,
pulg.
pulg.
Tuberia
05.fm Page 108 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
108
109
1 1/4
1
3/4
5/8
1/2
3/8
K
L
K
L
M
K
L
M
K
L
K
L
M
K
L
M
K
L
M
DWV
0.89
0.76
1.24
0.89
0.64
1.24
1.02
0.71
1.24
1.07
1.65
1.14
0.81
1.65
1.27
0.89
1.65
1.40
1.07
1.02
9.53
9.53
12.70
12.70
12.70
15.88
15.88
15.88
19.05
19.05
22.23
22.23
22.23
28.58
28.58
28.58
34.93
34.93
34.93
34.93
7.75
8.00
10.21
10.92
11.43
13.39
13.84
14.45
16.56
16.92
18.92
19.94
20.60
25.27
26.04
26.80
31.62
32.13
32.79
32.89
0.030
0.030
0.040
0.040
0.040
0.050
0.050
0.050
0.060
0.060
0.070
0.070
0.070
0.090
0.090
0.090
0.110
0.110
0.110
0.110
Exterior,
m2/m
0.0244
0.0250
0.0320
0.0344
0.0360
0.0421
0.0436
0.0454
0.0521
0.0530
0.0594
0.0628
0.0646
0.0792
0.0817
0.0841
0.0994
0.1009
0.1030
0.1033
Interior,
m2/m
Area de Superficie
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tuberia
1/4
Diámetro
Tamaño
Espesor de
Nominal Tipo
Pared
Exterior
Interior
E.U., pulg
t, mm
D, mm
d, mm
24
21
45
33
24
57
48
34
70
60
106
75
55
139
109
77
173
147
114
108
47
50
82
94
103
141
151
164
215
225
281
312
333
502
532
564
785
811
845
850
Area Metalica, Area de Flujo,
mm2
mm2
Sección Transversal
Tabla 5.2 (SI) Datos de Tubos de Cobre
05.fm Page 109 Thursday, March 3, 2016 12:42 PM
0.216
0.188
0.400
0.295
0.216
0.512
0.424
0.302
0.622
0.539
0.954
0.677
0.488
1.249
0.973
0.691
1.543
1.316
1.015
0.967
Tubo,
kg/m
0.047
0.050
0.082
0.094
0.103
0.141
0.151
0.164
0.215
0.225
0.281
0.312
0.333
0.502
0.532
0.564
0.785
0.811
0.845
0.850
Agua,
kg/m
Masa
Presión de Trabajoa,b,c
ASTM B88 a 120°C
MPa (Calibre)
Cocido
Estirado
5.868
11.004
5.033
9.432
6.164
11.556
4.399
8.253
3.144
5.895
4.930
9.246
4.027
7.543
2.820
5.282
4.109
7.702
3.523
6.605
4.668
8.757
3.234
6.061
2.303
4.309
3.634
6.812
2.792
5.240
1.958
3.668
2.972
5.571
2.517
4.716
1.924
3.599
1.827
3.427
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
4
3 1/2
3
2 1/2
2
1 1/2
K
L
M
DWV
K
L
M
DWV
K
L
M
K
L
M
DWV
K
L
M
K
L
M
DWV
1.83
1.52
1.24
1.07
2.11
1.78
1.47
1.07
2.41
2.03
1.65
2.77
2.29
1.83
1.14
3.05
2.54
2.11
3.40
2.79
2.41
1.47
41.28
41.28
41.28
41.28
53.98
53.98
53.98
53.98
66.68
66.68
66.68
79.38
79.38
79.38
79.38
92.08
92.08
92.08
104.78
104.78
104.78
104.78
37.62
38.23
38.79
39.14
49.76
50.42
51.03
51.84
61.85
62.61
63.37
73.84
74.80
75.72
77.09
85.98
87.00
87.86
97.97
99.19
99.95
101.83
Diámetro
Tamaño
Espesor de
Nominal Tipo
Pared
Exterior
Interior
E.U., pulg
t, mm
D, mm
d, mm
Tuberia
0.130
0.130
0.130
0.130
0.170
0.170
0.170
0.170
0.209
0.209
0.209
0.249
0.249
0.249
0.249
0.289
0.289
0.289
0.329
0.329
0.329
0.329
Exterior,
m2/m
0.1183
0.1201
0.1219
0.1228
0.1564
0.1585
0.1603
0.1628
0.1942
0.1966
0.1990
0.2320
0.2350
0.2378
0.2423
0.2701
0.2733
0.2761
0.3078
0.3115
0.3139
0.3200
Interior,
m2/m
Area de Superficie
226
190
157
135
343
292
243
177
487
413
337
666
554
446
281
852
714
596
1084
895
776
478
1 111
1 148
1 181
1 203
1 945
1 997
2 045
2 111
3 004
3 079
3 154
4 282
4 395
4 503
4 667
5 806
5 944
6 063
7 538
7 727
7 846
8 144
Area Metalica, Area de Flujo,
mm2
mm2
Sección Transversal
Tabla 5.2 (SI) Datos de Tubos de Cobre (Continuo)
05.fm Page 110 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
2.025
1.701
1.399
1.204
3.070
2.606
2.171
1.585
4.35
3.69
3.02
5.96
4.95
3.98
2.51
7.62
6.39
5.33
9.69
8.00
6.94
4.27
Tubo,
kg/m
1.111
1.148
1.182
1.203
1.945
1.997
2.045
2.111
3.004
3.079
3.154
4.282
4.395
4.503
4.667
5.806
5.944
6.063
7.538
7.727
7.846
8.144
Agua,
kg/m
Masa
Presión de Trabajoa,b,c
ASTM B88 a 120°C
MPa (Calibre)
Cocido
Estirado
2.786
5.226
2.324
4.351
1.896
3.558
1.627
3.048
2.455
4.606
2.069
3.951
1.717
3.220
1.241
2.331
2.275
4.268
1.917
3.592
1.558
2.917
2.193
4.109
1.813
3.392
1.448
2.717
0.903
1.696
2.082
3.903
1.738
3.254
1.441
2.703
2.041
3.827
1.675
3.144
1.448
2.717
0.883
1.655
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
110
K
L
M
DWV
K
L
M
DWV
K
L
M
DWV
K
L
M
K
L
M
4.06
3.18
2.77
1.83
4.88
3.56
3.10
2.11
6.88
5.08
4.32
2.77
8.59
6.35
5.38
10.29
7.11
6.45
130.18
130.18
130.18
130.18
155.58
155.58
155.58
155.58
206.38
206.38
206.38
206.38
257.18
257.18
257.18
307.98
307.98
307.98
122.05
123.83
124.64
126.52
145.82
148.46
149.38
151.36
192.61
196.22
197.74
200.84
240.00
244.48
246.41
287.40
293.75
295.07
0.409
0.409
0.409
0.409
0.489
0.489
0.489
0.489
0.648
0.648
0.648
0.648
0.808
0.808
0.808
0.968
0.968
0.968
Exterior,
m2/m
0.3834
0.3889
0.3917
0.3975
0.4581
0.4663
0.4694
0.4755
0.6050
0.6163
0.6212
0.6309
0.7541
0.7681
0.7742
0.9028
0.9229
0.9269
Interior,
m2/m
Area de Superficie
1610
1266
1108
737
2309
1698
1484
1016
4314
3212
2741
1771
6705
5004
4259
9621
6722
6112
11 699
12 042
12 201
12 572
16 701
17 311
17 525
17 993
29 137
30 238
30 710
31 680
45 241
46 942
47 686
64 873
67 771
68 382
Area Metalica, Area de Flujo,
mm2
mm2
Sección Transversal
14.39
11.32
9.91
6.59
20.64
15.18
13.27
9.09
38.56
28.71
24.50
15.83
59.93
44.73
38.07
85.99
60.09
54.63
Tubo,
kg/m
11.70
12.04
12.20
12.57
16.70
17.31
17.53
17.99
29.14
30.24
30.71
31.62
45.15
46.94
47.69
64.87
67.77
68.38
Agua,
kg/m
Masa
Presión de Trabajoa,b,c
ASTM B88 a 120°C
MPa (Calibre)
Cocido
Estirado
1.965
3.682
1.531
2.875
1.338
2.510
0.883
1.655
1.972
3.696
1.434
2.696
1.255
2.351
0.855
1.600
2.096
3.930
1.544
2.903
1.317
2.468
0.841
1.579
2.096
3.937
1.551
2.910
1.317
2.468
2.103
3.937
1.455
2.724
1.317
2.468
c
altas de los tubos pueden ser calculadas utilizando las tensiones admisibles para temperaturas más bajas.
Si los accesorios soldados o de soldadura fuerte son utilizados en tubos estirados en frio, utilice las capacidades de recocido. Presiones admisibles de tubo completo pueden utilizarse con accesorios de
tipo de compresión o con flama nominal adecuada.
a Cuando se utilizan accesorios soldados o de soldadura fuerte, la junta determina la presión límite.
b Las presiones de trabajo fueron calculadas utilizando tensiones admisibles de la Norma ASME B3 1.9. Un 5% de tolerancia de laminador ha sido utilizado en el espesor de la pared. Las capacidades más
12
10
8
6
5
Diámetro
Tamaño
Espesor de
Nominal Tipo
Pared
Exterior
Interior
E.U., pulg
t, mm
D, mm
d, mm
Tabla 5.2 (SI) Datos de Tubos de Cobre (Continuo)
05.fm Page 111 Thursday, March 3, 2016 12:42 PM
Tuberia
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
111
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Tipo y
Grado
Termoplasticos
PVC 1120
T I,G1
PVC 1200
T I,G2
PVC 2120
T II,G1
CPVC 4120 T IV,G1
PB 2110
T II,G1
PE 2306
Gr. P23
PE 3306
Gr. P34
PE 3406
Gr. P33
HDPE 3408 Gr. P34
PP
Copolímer
ABS
o de
acrilonitrilo
ABS 1210
T I,G2
ABS 1316
T I,G3
ABS 2112
T II,G1
PVDF
Designación
Material
Tuberia
5-2-2
3-5-5
4-4-5
7,000
5,500
6-3-3
1,275
1,600
705
2,000
1,000
8,000
4,800
5,000
5,000
2,000
7,500
355434-C
12454-B
12454-C
14333-D
23447-B
Celda
No.
1,000
1,600
1,250
2,000
2,000
2,000
2,000
1,000
630
630
630
800
280
176
140
212
210
180
140
180
180
180
275
150
150
150
210
210
140
160
180
180
210
640
1,000
800
306
800
320
<500
440
1.78
1.06
0.96
0.91
1.55
0.93
1.40
3.8
8.5
12
1.3
1.5
0.8
125,000
250,000
340,000
240,000
423,000
38,000
90,000
130,000
150,000
110,000
120,000
420,000
410,000
55.0
40.0
40.0
79.0
56.0
30.0
35.0
30.0
35.0
72.0
80.0
70.0
60.0
120.0
60.0
0.8
1.7
2.7
1.3
0.95
1.5
1.1
28.0
3.4
1.1
2.9
2.9
2.9
1.0
Limite de
Coeficiente
Fuerza de Modulo de
Conductividad, Costo
Temperatura Limite
de
Relativ
Gravedad Impacto, Elasticida,
Térmica
Superior, °F Superior,
Expansión,
b
c
o de
Btu·pulg/
HDS , Especifica pie·lb/pulg
psi
pulg/106
2·°F
psi
(a
73°F)
Tubod
h·pie
(a
73°F)
ASME
pulg·°F
Fab.
B31
Propiedades de Materiales de Tubos Plásticosa [2012S, Ch 46, Tbl 7]
Tensión de
Resistencia
Diseño
a la
Hidrostáticob,
Tracción,
psi (a 73°F)
psi
ASME
(a 73°F)
Fab.
B31
Tabla 5.3 (I-P)
05.fm Page 112 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
112
Tipo y
Grado
ERW
Estirado
Celda
No.
9,000
44,000
60,000
36,000
8,000
44,000
12,800
9,000
Tensión de
Resistencia
Diseño
a la
Hidrostáticob,
Tracción,
psi (a 73°F)
psi
ASME
(a 73°F)
Fab.
B31
200
800
400
200
300
9,200
8,200
5,000
7,000
7.80
8.90
30.0
27,500,000
17,000,000
1,000,000
1,000,000
6.31
9.5
9 to 11
9 to 13
344
1.3
2.9
1.3
3.5
Limite de
Coeficiente
Fuerza de Modulo de
Conductividad, Costo
Temperatura Limite
de
Impacto,
Relativ
Gravedad
Térmica
Superior,
Elasticida,
Superior, °F
Expansión,
b,
c
o de
Especifica pie·lb/pulg
Btu·pulg/
HDS
psi
pulg/106
2
psi
(a 73°F)
Tubod
h·pie ·°F
(a 73°F)
ASME
pulg·°F
Fab.
B31
Propiedades de Materiales de Tubos Plásticosa [2012S, Ch 46, Tbl 7] (Continuo)
Las propiedades enumeradas son para materiales específicos enumerados ya que cada plástico tiene otras formulaciones. Consulte al fabricante del sistema elegido. Estos valores son para propósitos comparativos.
La tensión de diseño hidrostático (HDS) es equivalente a la tensión de diseño admisible.
Relativo al agua a 62.4 lb/pie3
Basado sólo en costo de tubería, sin factorización en accesorios, juntas, perchas y mano de obra.
Tuberia
113
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
a
b
c
d
Epoxi-Glass
RTRP11AF
PoliésterRTRPGlass
12EF
Para Comparación
Acerp
A 53 B
Cobre
Tipo L
Termoestable
Designación
Material
Tabla 5.3 (I-P)
05.fm Page 113 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Tipo
y Grado
Termoplasticos
PVC 1120
T I,G1
PVC 1200
T I,G2
PVC 2120
T II,G1
CPVC 4120
T IV,G1
PB 2110
T II,G1
PE 2306
Gr. P23
PE 3306
Gr. P34
PE 3406
Gr. P33
HDPE 3408
Gr. P34
PP
Copolímero
ABS
de
acrilonitrilo
ABS 1210
T I,G2
ABS 1316
T I,G3
ABS 2112
T II,G1
PVDF
Designación
Material
Tuberia
5-2-2
3-5-5
4-4-5
48
38
6-3-3
8.8
11
4.9
14
7
55
33
34
34
14
52
355434-C
12454-B
12454-C
14333-D
23447-B
Celda
No.
7
11
8.6
14
14
14
14
7
4.3
4.3
4.3
5.5
Tensión de
Resistencia
Diseño
a la
Hidrostáticob
Tracción, MPa (a 23°C)
MPa
(a 23°C) Fab. ASME
B31
138
80
60
100
99
82
60
82
82
82
135
66
66
66
99
82
60
70
82
82
99
4.4
6.9
5.5
2.1
5.5
2.2
3.4
3.0
1780
1060
960
910
1550
930
1400
200
450
640
70
80
43
0.86
1.72
2.34
1.65
2.92
0.26
0.62
0.90
1.03
0.76
0.83
2.90
2.83
99
72
72
142
101
54
63
54
63
130
144
126
108
216
108
0.115
0.245
0.389
0.187
0.137
0.216
0.159
28.0
3.4
1.1
2.9
2.9
2.9
1.0
Upper
Modulo de Coeficiente
Costo
Temperature Limite
Fuerza de
Conductividad,
Densidad,
Elasticidad,
Relativo
de
Limit, °C Superior,
Impacto
Térmica, W/
b
3
kg/m
GPa
HDS ,
de
Expansión ,
(a 23°C)
(m·K)
(a 23°C) m/(m·K)
Tuboc
ASME MPa
Fab.
B31
Tabla 5.3 (SI) Propiedades de Materiales de Tubos Plásticosa [2012S, Ch 46, Tbl 7]
05.fm Page 114 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
114
Tipo
y Grado
Celda
No.
62
303
413
248
55
303
88
62
Tensión de
Resistencia
Diseño
a la
Hidrostáticob
Tracción, MPa (a 23°C)
MPa
(a 23°C) Fab. ASME
B31
93
99
427
204
63
56
34
48
7800
8900
1600
190
117
6.90
6.90
11.4
17.1
16 to 20
16 to 23
49.6
0.187
0.418
1.3
3.5
Upper
Modulo de Coeficiente
Costo
Temperature Limite
Fuerza de
Conductividad,
Densidad,
Elasticidad,
Relativo
de
Limit, °C Superior,
Impacto
Térmica, W/
b,
3
kg/m
GPa
HDS
de
Expansión ,
(a 23°C)
(m·K)
(a 23°C) m/(m·K)
Tuboc
ASME MPa
Fab.
B31
Las propiedades enumeradas son para materiales específicos enumerados ya que cada plástico tiene otras formulaciones. Consulte al fabricante del sistema elegido. Estos valores son para propósitos comparativos.
La tensión de diseño hidrostático (HDS) es equivalente a la tensión de diseño admisible.
Basado sólo en costo de tubería, sin factorización en accesorios, juntas, perchas y mano de obra.
Tuberia
115
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
a
b
c
Termoestable
Epoxi-Glass RTRP-11AF
PoliésterRTRP-12EF
Glass
Para Comparación
Acerp
A 53 B
ERW
Cobre
Tipo L
Estirado
Designación
Material
Tabla 5.3 (SI) Propiedades de Materiales de Tubos Plásticosa [2012S, Ch 46, Tbl 7] (Continuo)
05.fm Page 115 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
2.5 a 12 pulg. (65 a 300 mm)
XS
A53 B ERW acero
XS
A53 B ERW acero
Standard
Estándarc
A53 B ERW acero
Acero
SDR-11
Estándarc
PB
Acero (CW)
Vapor y Condensado
2 pulg, (50 mm) y menor
Estándar
A 53 B ERW acero
2.5 a 12 pulg. (65 a 300 mm)
Peso
Estándar
Tipo L
Sch 80
Sch 80
SDR-11
Material de Tubo
Clase
Sistema
Presión Máxima a
Temperatura,
Material
Temperaturaa, psig
°F (°C)
[kPa (calibre)]
Hierro fundido
250 (120)
125 (860)
Cobre forjado
250 (120)
200 (1030)
PVC
75 (24)
CPVC
150 (65)
PB
160 (70)
Metal
160 (70)
Acero forjado
250 (120)
400 (2760)
Acero forjado
250 (120)
250 (1720)
Hierro fundido
250 (120)
175 (1200)
Hierro fundido
250 (120)
400 (2760)
MI o hierro dúctil
230 (110)
300 (2070)
PB
160 (70)
Hierro Forjado
90 (620)
Hierro Maleable
90 (620)
Hierro Forjado
100 (690)
Hierro Maleable
125 (860)
Hierro Forjado
200 (1380)
Hierro Maleable
250 (1720)
Acero forjado
250 (1720)
Acero forjado
200 (1380)
Hierro forjado
100 (690)
Acero forjado
700 (4830)
Acero forjado
500 (3450)
Hierro forjado
200 (1380)
Accesorios
Hilo
125
Soldadura o soldadura de platab
Solvente
Sch 80
Solvente
Sch 80
Fusión por calor
Reborde de Inserción
Soldadura
Estándar
Brida
150
Brida
125
Brida
250
Ranura
Fusión por calor
Hilo
125
Hilo
150
Hilo
125
Hilo
150
Hilo
250
Hilo
300
Soldadura
Estándar
Brida
150
Brida
125
Soldadura
XS
Brida
300
Brida
250
Tipo de Junta
Tabla 5.4 Aplicación de Tubos, Accesorios y Valvulas Para Calefaccion y Aire Acondicionado
Acero (CW)
Agua de Recirculación
2 pulg (50 mm) y más pequeños Cobre, duro
PVC
CPVC
PB
Aplicación
Tuberia
05.fm Page 116 Thursday, March 3, 2016 12:42 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
116
117
Estándar
SDR-11
Acero, galvanizado
PB
Fusión por calor
Reborde de inserción
Hilo
Soldadura o soldadura de platab
MJ
Fusión por calor
Reborde de Inserción
Soldadura o soldadura de platab
Soldar
Soldadura
Tipo de Junta
150
125
MJ
Clase
Cobre forjado
Hierro forjado
PB
Metal
Cobre forjado
Hierro forjado
galvanizado
Hierro maleable
galvanizado
PB
Metal
Cobre forjado
Acero forjado
Material
Accesorios
75 (24)
75 (24)
75 (24)
75 (24)
75 (24)
75 (24)
75 (24)
75 (24)
75 (24)
125 (860)
125 (860)
350 (2410)
350 (2410)
250 (1720)
Sistema
Presión Máxima a
Temperatura,
Temperaturaa, psig
°F (°C)
[kPa (calibre)]
Máximas presiones de trabajo admisible han sido rebajadas en esta tabla. Mayores presiones del sistema pueden ser utilizadas para temperaturas menores y tamaños de tuberías más pequeños. Tuberías, accesorios,
juntas y válvulas deben ser todas consideradas.
Cobre, duro
Tipo K
Clase 50
SDR 9, 11
SDR 7, 11.5
Tipo L
Tipo L or K
Estándar
Peso
Cobre, duro
Hierro ductil
PB
Cobre, duro
A53 B SML acero
Material de Tubo
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tuberia
b Soldaduras basadas en plomo y antimonio no deben utilizarse para sistemas de agua potable. Soldaduras y soldaduras de plata deben utilizarse.
c Tubos extra fuerte es recomendado para toda la tubería de condensado roscada para permitir la corrosión.
a
Agua Potable,
Dentro del edificio
Aguas Subterráneas
A través de 12 pulg. (300 mm)
A través de 6 pulg. (150 mm)
Refrigerante
Aplicación
Tabla 5.4 Aplicación de Tubos, Accesorios y Valvulas Para Calefaccion y Aire Acondicionado (Continuo)
05.fm Page 117 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
05.fm Page 118 Thursday, March 3, 2016 12:42 PM
–30
–20
–10
0
10
20
32
40
50
60
70
80
90
100
120
140
160
180
200
212
220
240
260
280
300
320
340
360
380
400
500
600
700
800
900
1000
Expansión Térmica Lineal, pulg./100 pie
Acero
Acero Inoxidable
Cobre
Carbono
Tipo 304
–0.19
–0.30
–0.32
–0.12
–0.20
–0.21
–0.06
–0.10
–0.11
0
0
0
0.08
0.11
0.12
0.15
0.22
0.24
0.24
0.36
0.37
0.30
0.45
0.45
0.38
0.56
0.57
0.46
0.67
0.68
0.53
0.78
0.79
0.61
0.90
0.90
0.68
1.01
1.02
0.76
1.12
1.13
0.91
1.35
1.37
1.06
1.57
1.59
1.22
1.79
1.80
1.37
2.02
2.05
1.52
2.24
2.30
1.62
2.38
2.43
1.69
2.48
2.52
1.85
2.71
2.76
2.02
2.94
2.99
2.18
3.17
3.22
2.35
3.40
3.46
2.53
3.64
3.70
2.70
3.88
3.94
2.88
4.11
4.18
3.05
4.35
4.42
3.23
4.59
4.87
4.15
5.80
5.91
5.13
7.03
7.18
6.16
8.29
8.47
7.23
9.59
9.79
8.34
10.91
11.16
9.42
12.27
12.54
118
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
–14.6
–14.6
–14.5
–14.4
–14.3
–14.2
–14.0
–13.7
–13.0
–11.8
–10.0
–7.2
–3.2
0
2.5
10.3
20.7
34.6
52.3
75.0
103.3
138.3
181.1
232.6
666.1
1528
3079
Temperatura,
°F
Tuberia
Vacío
Presión de Vapor
Saturada, psig
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 5.5 (I-P) Expansión Térmica de Tubos de Metal
05.fm Page 119 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 5.5 (SI) Expansión Térmica de Tubos de Metal
Expansión Térmica Lineal, mm/m
Vaccío
Presión de Vapor
Saturada, kPa (gage)
Acero
Carbono
Acero Inoxidable
Tipo 304
Cobre
34
29
23
18
12
7
0.16
0.10
0.05
0
0.07
0.13
0.25
0.17
0.08
0
0.09
0.18
0.27
0.18
0.09
0
0.10
0.20
100.7
100.7
100.0
99.3
98.6
97.9
96.5
94.5
89.6
81.4
69.0
49.6
22.1
0
0
4
10
16
21
27
32
38
49
60
71
82
93
100
0.20
0.25
0.32
0.38
0.44
0.51
0.57
0.63
0.76
0.88
1.02
1.14
1.27
1.35
0.30
0.38
0.47
0.56
0.65
0.75
0.84
0.93
1.13
1.31
1.49
1.68
1.87
1.98
0.31
0.38
0.47
0.57
0.66
0.75
0.85
0.94
1.14
1.33
1.50
1.71
1.92
2.03
17.2
104
1.41
2.07
2.10
71.0
116
1.54
2.26
2.30
142.7
127
1.68
2.45
2.49
238.6
138
1.82
2.64
2.68
360.6
149
1.96
2.83
2.88
517.1
160
2.11
3.03
3.08
712.3
171
2.25
3.23
3.28
953.6
182
2.40
3.43
3.48
1 249
193
2.54
3.63
3.68
1 604
204
2.69
3.83
4.06
9 039
304
4.11
5.65
5.77
404
5.67
7.56
7.72
504
7.31
9.54
9.76
Tuberia
119
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temperatura,
°C
05.fm Page 120 Thursday, March 3, 2016 12:42 PM
NPS, in.
1/2
3/4
1
1 1/2
2
2 1/2
3
4
6
8
10
12
14
16
18
20
Espaciamiento de Percha, pie
Tubo de Acero Standar*
Tubo de Cobre
Agua
Vapor
Agua
7
7
7
9
10
11
12
14
17
19
20
23
25
27
28
30
8
9
9
12
13
14
15
17
21
24
26
30
32
35
37
39
5
5
6
8
8
9
10
12
14
16
18
19
Tamaño de Varilla,
pulg.
1/4
1/4
1/4
3/8
3/8
3/8
3/8
1/2
1/2
5/8
3/4
7/8
1
1
1 1/4
1 1/4
Fuente: Adaptado de Norma MSS SP-69
* El espacio no aplica donde los cálculos de extensión son hechos o donde las cargas concentradas son colocadas
entre soportes como bridas, válvulas, especialidades, etc.
Espaciamiento de Percha, m
Diámetro Exterior
Tubo de Acero Standar*
Tubo de Cobre
Nominal, mm
Agua
Vapor
Agua
15
2.1
2.4
1.5
20
2.1
2.7
1.5
25
2.1
2.7
1.8
40
2.7
3.7
2.4
50
3.0
4.0
2.4
65
3.4
4.3
2.7
80
3.7
4.6
3.0
100
4.3
5.2
3.7
150
5.2
6.4
4.3
200
5.8
7.3
4.9
250
6.1
7.9
5.5
300
7.0
9.1
5.8
350
7.6
9.8
400
8.2
10.7
450
8.5
11.3
500
9.1
11.9
Tamaño de Varilla,
mm
6.4
6.4
6.4
10
10
10
10
13
13
16
19
22
25
25
32
32
Fuente: Adaptado de Norma MSS SP-69
* El espacio no aplica donde los cálculos de extensión son hechos o donde las cargas concentradas son colocadas
entre soportes como bridas, válvulas, especialidades, etc.
120
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tuberia
Tabla 5.6 (SI) Espaciamiento de Percha Sugerido y Tamaño de Varillas para
Tramos Horizontales Rectos
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 5.6 (I-P) Espaciamiento de Percha Sugerido y Tamaño de Varillas para
Tramos Horizontales Rectos
05.fm Page 121 Thursday, March 3, 2016 12:42 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 5.7 (I-P) Capacidades de Varillas Trenzadas de Acero ASTM A36
Diámetro de Varilla,
Area de Raíz de Hilo Grueso,
Carga Maxima,*
lb
pulg.
pulg2
1/4
0.027
240
3/8
0.068
610
1/2
0.126
1130
5/8
0.202
1810
3/4
0.302
2710
7/8
0.419
3770
1
0.552
4960
1 1/4
0.889
8000
* Basado en una tensión admisible de 12,000 psi reducido al 25% utilizando la raíz de área de acuerdo con la norma
B31.1 de ASME y Norma MSS SP-58.
Tabla 5.7 (SI)
Capacidades de Varillas Trenzadas de Acero ASTM A36
Diámetro de Varilla,
mm
Area de Raíz de Hilo Grueso,
mm2
Carga Maxima,*
N
6.4
17.4
1 070
10
43.9
2 720
13
81.3
5 030
16
130.3
8 060
19
194.8
12 100
22
270.3
16 800
25
356.1
22 100
32
573.5
35 600
* Basado en una tensión admisible de 83,000 MPa reducido al 25% utilizando la raíz de área de acuerdo con la norma
B31.1 de ASME y Norma MSS SP-58.
Tuberia
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
121
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
06.fm Page 122 Thursday, March 3, 2016 12:43 PM
Servicio de Calentamiento
de Agua
SERVICIO DE CALENTAMIENTO DE AGUA
El uso de energía de calentamiento de agua es solamente superado por el espacio acondicionado en la mayoría de edificios de viviendas y es también importante en muchos entornos industriales y comerciales. En algunos climas y aplicaciones, el calentamiento de agua es el uso mayor
de energía en un edificio. Además, la disponibilidad rápida de cantidades adecuadas de agua caliente es un factor importante en satisfacción del usuario. Ambos, derroche de energía y agua puede
ser significativo en sistemas pobremente diseñados de servicio de calentamiento de agua: de equipos y tuberías de más o infradimensión, de diseño pobre de la construcción y de mal diseño de
sistemas y estrategias de operación. Buen servicio de diseño del sistema de calentamiento de agua
y prácticas operativas pueden a menudo reducir los primeros costos y costos operativos.
Elementos del Sistema
Un sistema de servicio de calentamiento de agua tiene: (1) una o más fuentes d de energía de
calor, (2) equipo de transferencia de calor, (3) un sistema de distribución y (4) dispositivos de uso
de terminales de agua caliente.
Las Fuentes de energía de calor pueden ser (1) quema de combustible; (2) conversión eléctrica; (3) geotérmica, aire u otra energía ambiental; y/o (5) calor residual recuperado de fuentes
como gases de combustión, sistemas de aire acondicionado y ventilación, ciclos de refrigeración y
proceso de descarga de desperdicios.
El Equipo de transferencia de calor es directo, indirecto o una combinación de los dos.
Para equipo directo, el calor es derivado de la quema de combustible o conversión directa de
energía eléctrica en calor y es aplicada dentro del equipo de calentamiento de agua. Para equipo
de transferencia de calor indirecta, la energía de calor es desarrollada de fuentes de calor remotas
(ej. calderos; colección de energía solar; aire, geotérmica u otra fuente ambiental; cogeneración;
refrigeración; calor residual) y es después transferida al agua en una pieza separada de equipo.
Tanques de almacenamiento pueden ser parte de o asociadas con cualquier tipo de equipo de
transferencia de calor.
El Terminal de dispositivos de uso de agua son accesorios de plomería y equipo que requieren agua caliente que pueden tener períodos de flujo irregular, flujo constante y ningún flujo.
Estos patrones y el uso de agua relacionado varían con diferentes edificios, aplicaciones de proceso y preferencias personales.
Legionella pheumophila (Enfermedad de Legionarios)
La enfermedad de Legionarios (una forma de neumonía grave) es causada por la inhalación
de la bacteria Legionella pneumophila. Esto ha sido descubierto en el sistema de agua de servicios
de varios edificios a través del mundo.
La temperatura del agua de servicio en el margen de 140°F (60°C) es recomendado para limitar el potencial para el crecimiento de L. pneumophila. Esta temperatura alta aumenta el potencial
de escaldado, por consiguiente cuidado debe tenerse como instalar una válvula mezcladora o contra escaldadura.
Más información sobre este tema puede ser encontrado en la Pauta 12-2000 de ASHRAE.
122
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Los Sistemas de distribución transportan agua caliente producida por equipo de calentamiento de agua al terminal de dispositivos de uso de agua caliente. El agua consumida debe ser
repuesta del servicio principal de agua del edificio. Para sitios donde constante suministro de temperaturas son deseados, la tubería de circulación o un medio de mantenimiento de calor deben ser
suministrados.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
6.
06.fm Page 123 Thursday, March 3, 2016 12:43 PM
Tabla 6.1
Uso Residencial Típico de Agua Caliente [2011ª, Ch 50, Tbl 4]
Flujo Bajo
(Ahorradores de
Agua Usados),
Galones/Tarea
(Litros/Tarea)
Flujo Ultra bajo,
Galones/Tarea
(Litros/Tarea)
Preparación de comida
Lavar platos a mano
Lavavajilla automática
Lavadora de ropa
Ducha o bañera
Lavar manos y cara
5 (19)
4 (15)
15 (57)
32 (121)
20 (76)
4 (15)
3 (11)
4 (15)
15 (57)
21 (80)
15 (57)
2 (8)
3 (11)
3 (11)
3 a 10 (38)
5 a 15 (57)
10 a 15 (57)
1 a 2 (8)
123
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Uso
Flujo Alto,
Galones/Tarea
(Litros/Tarea)
Servicio de Calentamiento
de Agua
La mayor dificultad en el diseño de sistemas de calentamiento de agua viene de la incertidumbre acerca del diseño de las cargas de agua caliente, especialmente para edificios aún no construidos. Aunque esto es bastante simple para probar las velocidades de flujo máximas de varios
aparatos y accesorios de agua caliente, las velocidades de flujo actuales y duración son dependientes del usuario. Además, el tiempo de los diferentes eventos de uso de agua caliente varía de día a
día, con algunas coincidencias, pero casi nunca todos los accesorios serán utilizados simultáneamente. Como el número de aparatos y accesorios que utilizan agua caliente crece, el porcentaje de
estos accesorios utilizados simultáneamente decrece.
Parte de la información de carga de agua caliente aquí está basada en la prueba de campo de
escala limitada combinada con análisis estadístico para estimar la demanda de carga o factor de
diversidad (porcentaje de la carga posible total que es en realidad utilizada en un momento) versus el número de puntos de uso final, número de personas, etc. La mayoría del trabajo para
proveer estos factores de diversidad datan de 1930 a los 1960; sigue siendo, sin embargo, la mejor
información disponible actualmente (con unas pocas excepciones, como se ha señalado). De
mucha preocupación es el hecho de que la mayoría de los datos de aquellos estudios tempranos
fueron para accesorios que utilizaban agua a caudales mucho más altos que los accesorios de eficiencia energética modernos (ej. cabezales de ducha de flujo bajo y aireadores de fregadero, lavavajillas y lavadoras de eficiencia energética). Utilizando la información de diversidad de carga
mayor usualmente resulta en un sistema de calentamiento d agua que adecuadamente sirve las cargas, pero a menudo resulta en sobredimensionamiento sustancial. El sobredimensionamiento
puede ser un disuasivo para el uso de equipo de calentamiento de agua de alto rendimiento, el cual
puede tener costos muy altos por unidad de capacidad que el equipo menos eficiente.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Diversidad de Carga
Tabla 6.2 (I-P) HUD-FHA Capacidades Mínimas de Calentamiento de Agua para
Unidades de Vivienda de Una y Dos Familias [2011A, Ch 50, Tbl5]
Número de Baños
Número de Dormitorios
Gasa
Almacenamiento, gal
1000 Btu/h entrada
1 h descarga, gal
Recuperación, gph
Eléctricoa
Almacenamiento, gal
kW entrada
1 h descarga, gal
Recuperación, gph
Aceitea
Almacenamiento, gal
1000 Btu/h entrada
1 h descarga, gal
Recuperación, gph
Tipo Tanque Indirectob,c
I-W-H-descarga nominal,
gal en 3 h, 100°F elevación
Fabricante, descarga nominal,
gal en 3 h, 100°F elevación
Capacidad tanque, gal
1 a 1.5
2
3
2
2 a 2.5
3
4
5
3
3 a 3.5
4
5
6
50
50
92
42
20
27
43
23
30
36
60
30
30
36
60
30
30
36
60
30
40
36
70
30
40
38
72
32
50
47
90
40
40
38
72
32
50
38
82
32
50
47
90
40
20
2.5
30
10
30
3.5
44
14
40
4.5
58
18
40
4.5
58
18
50
5.5
72
22
50
5.5
72
22
66
5.5
88
22
50
5.5
72
22
66
5.5
88
22
66 80
5.5 5.5
88 102
22 22
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
30
70
89
59
40
40
66
66e
66
66
66
66
66
e
49
49
75
75
75
75
75
75
75
66
66
66
66e
82
66
82
82
82
2.75 2.75
15
15
3.25 3.25e 3.75 3.25 3.75 3.75 3.75
25
25e
35
25
35
35
tanque.
35
Nota: Aplica sólo a calentadores de agua tipo
Capacidad de almacenamiento, entrada y requisitos de recuperación indicados son típicos y pueden variar con el
fabricante. Cualquier combinación de requisitos para producir 1 hora de descarga fija es satisfactoria.
b Capacidades de calentadores de agua conectados a una caldera (180°F agua de caldera, conexión interna o
externa).
c Capacidades del calentador y entradas son mínimo permisible. Variaciones en el tamaño del tanque son permitidas
cuando la recuperación está basada en 4 gph/kW a 100°F aumento para eléctrica. Valoración de recuperación de
AGA para gas, y valoración de IBR para vapor y calentadores de agua caliente.
d Capacidades de calentadores conectados a una caldera (200°F agua de caldera, conexión interna o externa).
e También para 1 a 1.5 baños y 4 dormitorios para calentadores de agua indirectos.
a
124
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tipo sin Tanque Indirectoc,d
I-W-H-descarga nominal, gpm,
100°F elevación
Fabricante, descarga nominal, gal
en 5 min, 100°F elevación
1
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Servicio de Calentamiento
de Agua
06.fm Page 124 Thursday, March 3, 2016 12:43 PM
06.fm Page 125 Thursday, March 3, 2016 12:43 PM
6
190
14.6
350
44
300
5.5
387
23
114
20.5
337
62
250
284
310
240
133
Tabla 6.3 Uso de Agua Caliente Promedio Total y Pico [2011A, Ch 50, Tbl 6]
Uso Promedio de Agua Caliente, gal (L)
Grupo
Cada Hora
Diario
Semanal
Mensual
Total
Pico
Total
Pico
Total
Pico
Total
Pico
Todaslas
familias
2.6
(9.8)
4.6
(17.3)
62.4
(236)
67.1
(254)
436
(1652)
495
(1873)
1897
(7178)
2034
(7700)
Familias
“típicas”
2.6
(9.9)
5.8
(21.9)
63.1
(239)
66.6
(252)
442
(1673)
528
(1981)
1921
(7270)
2078
(7866)
125
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota: Aplica sólo a calentadores de agua tipo tanque.
a Capacidad de almacenamiento, entrada y requisitos de recuperación indicados son ípicos y pueden variar con el
fabricante. Cualquier combinación de requisitos para producir 1 hora de descarga fija es satisfactoria.
b Capacidades de calentadores de agua conectados a una caldera (82°C agua de caldera, conexión interna o externa).
c Capacidades del calentador y entradas son mínimo permisible. Variaciones en el tamaño del tanque son permitidas
cuando la recuperación está basada en 4.2 mL (s·kW) a 55°C aumento para eléctrica, valoración de recuperación
de AGA para gas, y valoración de IBR para vapor y calentadores de agua caliente.
d Capacidades de calentadores conectados a una caldera (93°C agua de caldera, conexión interna o externa).
e También para 1 a 1.5 baños y 4 dormitorios para calentadores de agua indirectos.
Servicio de Calentamiento
de Agua
Número de Baños
1 a 1.5
2 a 2.5
3 a 3.5
Número de Dormitorios
1
2
3
2
3
4
5
3
4
5
Gasa
Almacenamiento, L
76 114 114 114 150 150 190 150 190 190
kW entrada
7.9 10.5 10.5 10.5 10.5 11.1 13.8 11.1 11.1 13.8
1 h descarga, L
163 227 227 227 265 273 341 273 311 341
Recuperación, mL/s
24 32 32
32 32 36 42
34 34
42
a
Eléctrico
Almacenamiento, L
76 114 150 150 190 190 250 190 250 250
kW entrad
2.5 3.5 4.5 4.5 5.5 5.5 5.5 5.5 5.5 5.5
1 h descarga, L
114 167 220 220 273 273 334 273 334 334
Recuperación, mL/s
10 15 19
19 23 23 23
23 23
23
Aceitea
Almacenamiento, L
114 114 114 114 114 114 114 114 114 114
kW entrada
20.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5
1 h descarga, L
337 337 337 337 337 337 337 337 337 337
Recuperación, mL/s
62 62 62
62 62 62 62
62 62
62
Tipo de tanques indirectob,c
I-W-H-descarga nominal, L en
150 150
250 250e 250 250 250 250
3 h, 55 K elevación
Fabricante-descarga nominal,
186 186
284 284e 284 284 284 284
L en 3 h, 55 K elevación
Capacidad de Tanque, L
250 250
250 250e 310 250 310 310
Tipo sin tanque indirectoc,d
I-W-H-descarga nominal,
170 170
200 200e 240 200 240 240
mL/s, 55 K elevación
Fabricante-descarga nominal,
57 57
95 95e 133 95 133 133
L en 5 min, 55 K elevación
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 6.2 (SI) HUD-FHA Capacidades Mínimas de Calentamiento de Agua para
Unidades de Vivienda de Una y Dos Familias [2011A, Ch 50, Tbl5]
Tabla 6.4 Demandas de Agua Caliente y Uso para Varios Tipos de Edificios*
[201A, Ch 50, Tbl 7]
Tipo de Edificio
Máximo por Hora
Dormitorios para
hombres
3.8 gal/estudiante
(14.4 L/estudiante)
5.0 gal/estudiante
Dormitorios para mujeres
(19 L/estudiante)
Moteles: Número de unidadesa
6.0 gal/unidad
20 o menos
(23 L/unidad)
5.0 gal/unidad
60
(20 L/unidad)
4.0 gal/unidad
100 o más
(15 L/unidad)
4.5 gal/cama
Hogares de Ancianos
(17 L/cama)
0.4 gal/persona
Edificio de Oficina
(1.5 L/persona)
Establecimientos de Comida
Tipo A: Restaurantes
1.5 gal/max comidas/h
de comida
(5.7 L/max comidas/h)
completa y
cafeterías
Tipo B: Drive-ins,
parrillas, cafeterías, 0.7 gal/max comidas/h
sánduche y tiendas (2.6 L/max comidas/h)
de aperitivos
Máximo Diario
Promedio Diario
22.0 gal/estudiante
(83.3 L/estudiante)
26.5 gal/estudiante
(100 L/estudiante
13.1 gal/estudiante
(49.7 L/estudiante)
12.3 gal/estudiante
(46.6 L/estudiante)
35.0 gal/unidad
(132.6 L/unidad)
25.0 gal/unidad
(94.8 L/unidad)
15.0 gal/unidad
(56.8 L/unidad)
30.0 gal/cama
(114 L/cama)
2.0 gal/persona
(7.6 L/persona)
20.0 gal/unidad
(75.8 L/unidad)
14.0 gal/unidad
(53.1 L/unidad)
10.0 gal/unidad
(37.9 L/unidad)
18.4 gal/cama
(69.7 L/cama)
1.0 gal/persona
(3.8 L/persona)
11.0 gal/max comidas/dia
(41.7 L/max comidas/día)
6.0 gal/max comidas/dia
(22.7 L/max comida/día)
42.0 gal/apartamento
(159.2 L/apartamento)
40.0 gal/aparatmento
(151.6 L/apartamento)
38.0 gal/apartamento
(144 L/apartment)
37.0 gal/apartamento
(140.2 L/apartamento)
35.0 gal/apartamento
(132.7 L/apartamento)
0.6 gal/estudianteb
(2.3 L/estudianteb)
1.8 gal/estudinteb
(6.8 L/estudianteb)
*Datos anteriores artefactos y accesorios de flujo bajo modernos.
a Interpolar para valores intermedios.
b Por dia de operación.
126
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Casas de apartamentos: Número de apartmentos
12.0 gal/apartamento
80.0 gal/apartamento
20 o menos
(45.5 L/ apartamento) (303.2 L/apartamento)
10.0 gal/apartamento
73.0 gal/apartamento
50
(37.9 L/apartmento)
(276.7 L/apartamento)
8.5 gal/apartamento
66.0 gal/apartamento
75
(32.2 L/apartamento)
(250 L/apartmento)
7.0 gal/apartamento
60.0 gal/apartamento
100
(26.5 L/apartamento)
(227.4 L/apartamento)
5.0 gal/apartamento
50.0 gal/apartamento
200 o más
(19 L/apartamento)
(195 L/apartamento)
0.6 gal/estudiante
1.5 gal/estudiante
Escuelas Primarias
(2.3 L/estudiante)
(5.7 L/estudiante)
1.0 gal/estudiante
3.6 gal/estudiante
Junior y bachilleratos
(3.8 L/estudiante)
(13.6 L/estudiante)
2.4 gal/comidas
promedo/diab
(9.1 L/promedio
comidas/diab)
0.7 gal/comidas
promedio/diab
(2.6 L/promedio
comidas/díab)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Servicio de Calentamiento
de Agua
06.fm Page 126 Thursday, March 3, 2016 12:43 PM
2
6
20
50–150
3
20
28
10
150
20
0.30
0.90
0.30
1.25
Club
Casa de
Apartamento
2
4
20
15
3
10
20
5
30
20
1.00
0.40
2
8
30
—
12
—
—
—
225
—
Gimnasio
0.60
2
6
20
50–150
3
20
28
10
75
20
400
600
100
35
30
165
20
10
0.25
Hospital
1.00
30
15
0.40
20
10
0.25
0.80
Planta
Industrial
2
12
—
20–100
12
20
—
—
225
20
2
8
20
50–200
3
30
28
10
75
30
Hotel
Nota: Fuentes de datos anteriores a artefactos y accesorios de flujo bajo.
a Los requisitos del lavaplatos serán tomados de la tabla o de los datos del fabricante par modelos a ser utilizados, si es conocido.
b Proporción de capacidad del tanque de almacenamiento para demanda/h máxima probable.
c Los baños Whirlpool requieren consideración específica basado en la capacidad. No están incluidos en la categoría de bañeras.
Lavabo, Lavatorio privado
Lavabo, lavatorio público
Bañerac
Lavaplatosa
Lavabo para pie
Fregadero Cocina
Lavandería, tina esstacionaria
Fregadero despensa
Ducha
Fregadero servicio
Ducha de hidroterapia
BañoHubbard
Baño de pierna
Baño de brazo
Baño de asiento
Baño de flujo continuo
Fregadero de lavado circular
Fregadero de lavado semi circular
FACTOR DE DEMANDA
FACTOR DE CAPACIDAD DE
20.
ALMACENAMIENTOb
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
2.00
20
10
0.30
Edificio
Oficina
2
6
—
—
—
20
—
10
30
20
0.70
0.30
Residencia
Privada
2
—
20
15
3
10
20
5
30
15
Tabla 6.5 (I-P) Demanda de Agua Caliente por Accesorio para Varios Tipos de Edificios [2011A, Ch 50, Tbl 10]
(Galones de agua por hora por accesorio, calculado a una temperatura final de 140°F)
06.fm Page 127 Thursday, March 3, 2016 12:43 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
127
1.00
30
15
0.40
2
15
—
20–100
3
20
—
10
225
20
Escuela
1.00
0.40
2
8
30
20–100
12
20
28
10
225
20
YMCA
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Servicio de Calentamiento
de Agua
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
7.6
23
76
190–570
11
76
106
38
568
76
0.30
0.90
0.30
1.25
Club
Casa de
Apartamento
7.6
15
76
57
11
38
76
19
114
76
Hospital
7.6
23
76
190–570
11
76
106
38
284
76
1520
2270
380
130
114
625
76
38
0.25
0.60
Gimnasio
7.6
30
114
—
46
—
—
—
850
—
0.40
1.00
1.00
114
57
0.40
76
38
0.25
0.80
Planta
Industrial
7.6
45.5
—
76–380
46
76
—
—
850
76
7.6
30
76
190–760
11
114
106
38
284
114
Hotel
2.00
76
38
0.30
Edificio de
Oficina
7.6
23
—
—
—
76
—
38
114
76
0.70
0.30
Residencia
Privada
7.6
—
76
57
11
38
76
19
114
57
Demanda de Agua Caliente por Accesorio para Varios Tipos de Edificios [2011A, Ch 50, Tbl 10]
(Litros de agua por hora por accesorio, calculado a una temperatura final de 60°C)
1.00
114
57
0.40
7.6
57
—
76–380
11
76
—
38
850
76
Escuela
1.00
0.40
7.6
30
114
76–380
46
76
106
38
850
76
YMCA
Servicio de Calentamiento
de Agua
Nota: Fuentes de datos anteriores a artefactos y accesorios de flujo bajo.
a Los requisitos del lavaplatos serán tomados de esta tabla o de los datos del fabricante par modelo a ser utilizado, si es conocido.
b Proporción de capacidad del tanque de almacenamiento para demanda/h máxima probable. La capacidad de almacenamiento puede ser reducida donde el suministro sin límites de vapor es disponible del
sistema de vapor central o planta de caldera grande.
c Los baños Whirlpool requieren consideración específica basado en la capacidad. No están incluidos en la categoría de bañeras.
Lavabo, lavatorio privado
Lavabo, lavatorio público
Bañerac
Lavaplatosa
Lavabo para pie
Fregadero de cocina
Lavandería, tina estacionaria
Fregadero de despensa
Ducha
Fregadero de servicio
Ducha de hidroterapia
Baño Hubbard
Baño de la pierna
Baño del brazo
Baño de asiento
Baño de flujo continuo
Fregadero de lavado circular
Fregadero de lavado semicircular
FACTOR DE DEMANDA
FACTOR DE CAPACIDAD DE
20.
ALMACENAMIENTOb
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
Tabla 6.5 (SI)
06.fm Page 128 Thursday, March 3, 2016 12:43 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
128
06.fm Page 129 Thursday, March 3, 2016 12:43 PM
25°F
(14 K)
50°F
(28 K)
55°F
(31 K)
75°F
(42 K)
77°F
(43 K)
100°F
(56 K)
504
(0.15)
2,520
(0.74)
5,040
(1.48)
7,560
(2.22)
10,080
(2.95)
12,600
(3.69)
15,120
(4.43)
17,640
(5.17)
20,160
(5.91)
22,680
(6.65)
25,200
(7.39)
30,240
(8.86)
35,280
(10.3)
40,320
(11.8)
45,360
(13.3)
50,400
(14.8)
1,260
(0.37)
6,300
(1.85)
12,600
(3.69)
18,900
(5.54)
25,200
(7.39)
31,500
(9.23)
37,800
(11.1)
44,100
(12.9)
50,400
(14.8)
56,700
(16.6)
63,000
(18.5)
75,600
(22.2)
88,200
(25.8)
100,800
(29.5)
113,400
(33.2)
126,000
(36.9)
2,520
(0.74)
12,600
(3.69)
25,200
(7.39)
37,800
(11.1)
50,400
(14.8)
63,000
(18.5)
75,600
(22.2)
88,200
(25.8)
100,800
(29.5)
113,400
(33.2)
126,000
(36.9)
151,200
(44.3)
176,400
(51.7)
201,600
(59.1)
226,800
(66.5)
252,000
(73.9)
2,772
(0.81)
13,860
(4.06)
27,720
(8.12)
41,580
(12.2)
55,440
(16.2)
69,300
(20.3)
83,160
(24.4)
97,020
(28.4)
110,880
(32.5)
124,740
(36.6)
138,600
(40.6)
166,320
(48.7)
194,040
(56.9)
221,760
(65.0)
249,480
(73.1)
277,200
(81.2)
3,780
(1.11)
18,900
(5.54)
37,800
(11.1)
56,700
(16.6)
75,600
(22.2)
94,500
(27.7)
113,400
(33.2)
132,300
(38.8)
151,200
(44.3)
170,100
(49.9)
189,000
(55.4)
226,800
(66.5)
264,600
(77.5)
302,400
(88.6)
340,200
(99.7)
378,000
(110.8)
3,881
(1.14)
19,404
(5.69)
38,808
(11.4)
58,212
(17.1)
776,196
(22.8)
97,020
(28.4)
116,424
(34.1)
135,828
(39.8)
155,232
(45.5)
174,636
(51.2)
194,040
(56.9)
232,848
(68.2)
271,656
(79.6)
310,464
(91.0)
349,272
(102.4)
388,080
(113.7)
5,040
(1.48)
25,200
(7.39)
50,400
(14.8)
75,600
(22.2)
100,800
(29.5)
126,000
(36.9)
151,200
(44.3)
176,400
(51.7)
201,600
(59.1)
226,800
(66.5)
252,000
(73.9)
302,400
(88.6)
352,800
(103.4)
403,200
(118.2)
453,600
(132.9)
504,000
(147.7)
*Divida la tabla de valores por la eficiencia de entrada para determinar la tasa de entrada de calor requerida.
129
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
0.1
(6.3)
0.5
(31.5)
1.0
(63.1)
1.5
(94.6)
2.0
(126)
2.5
(158)
3.0
(189)
3.5
(221)
4.0
(252)
4.5
(284)
5.0
(315)
6.0
(379)
7.0
(442)
8.0
(505)
9.0
(568)
10.0
(631)
Elevación de Temperatura
10°F
(6 K)
Servicio de Calentamiento
de Agua
Tasa de
Flujo
gpm
(mL/s)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 6.6 Tasas de Calor de Salida de Calentador de Agua Sin Tanque Btu/h (kW)*
[2011A, Ch 50, Tbl 15]
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
—
—
—
—
1.5
2.5
—
1.5
2.5
2.5
1.5
2.5
1.5
—
1.5
0.75
1
—
Gimnasio
0.75
1
1.5
Club
0.75
—
1.5
1.5
—
0.75
—
1.5
1.5
—
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota: Datos anteriores artefactos y accesorios de flujo bajo modernos.
Lavabo, Lavatorio Privado
Lavavo, Lavatorio Público
Bañera
Lavaplatos*
Baño terapeútico
Fregadero de cocina
Fregadero de despensa
Fregadero de servicio
Ducha
Fuente de lavado circular
Fuente de lavado
semicircular
1.5
1.5
—
1.5
3
—
3
2.5
2.5
1.5
2.5
—
0.75
2.5
2.5
1.5
2.5
—
0.75
1
—
Planta Industrial Edificio de Oficina Escuela
0.75
1
—
Hoteles y Dormitrios
0.75
0.75
0.75
0.75
1
1
1
1
1.5
1.5
—
—
Cinco unidades de accesorios por 250 capacidades de asiento
5
—
—
—
3
1.5
3
—
2.5
2.5
—
—
2.5
2.5
2.5
2.5
1.5
1.5
3.5
—
2.5
—
4
—
Hospital
YMCA
Servicio de Calentamiento
de Agua
Demanda de Agua Caliente en Unidades de Accesorios [140°F (60°C) Agua] [2011A, Ch 50, Tbl 16]
Apartamentos
Tabla 6.7
06.fm Page 130 Thursday, March 3, 2016 12:43 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
130
06.fm Page 131 Thursday, March 3, 2016 12:43 PM
Servicio de Calentamiento
de Agua
Curva Cazador Modificada para el Cálculo del Caudal de Agua Caliente
[2011A, Ch 50, Fig 25]
(Datos Anteriores de Artefactos y Accesorios de Flujo Bajo Modernos)
131
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 6.1 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 6.1 (I-P) Curva Cazador Modificada para el Cálculo del Caudal de Agua Caliente
[2011A, Ch 50, Fig 25]
(Datos Anteriores de Artefactos y Accesorios de Flujo Bajo Modernos)
Figura 6.2 (I-P) Sección Ampliada de la Curva Cazador Modificada [2011A, Ch 50, Fig 26]
Datos Anteriores de Artefactos y Accesorios de Flujo Bajo Modernos)
132
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 6.2 (SI) Sección Ampliada de la Curva Cazador Modificada [2011A, Ch 50, Fig 26]
Datos Anteriores de Artefactos y Accesorios de Flujo Bajo Modernos)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Servicio de Calentamiento
de Agua
06.fm Page 132 Thursday, March 3, 2016 12:43 PM
07.fm Page 133 Thursday, March 3, 2016 12:44 PM
USO DE ENERGIA SOLAR
Uso de Energia Solar
Figura 7.1 (I-P) Márgenes de Uso Típico y Eficiencias de Varios Colectores Solares Líquidos
Márgenes de Uso Típico y Eficiencias de Varios Colectores Solares Líquidos
133
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 7.1 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
7.
07.fm Page 134 Thursday, March 3, 2016 12:44 PM
FR
Leyenda por Figura 7.1:
=
temperatura de fluido promedio, °F (°C)
=
temperatura aire ambiente, °F (°C)
=
radiación normal incidente, más radiación difusa, °F·ft2·h/Btu (K·m2/W)
=
coeficiente de pérdida de calor total
=
absorbencia
=
FR, –FRUL(t1 – ta)/t = eficiencia
=
fracción de radiación solar que llega al colector
=
factor de remoción de calor del colect
Tabla 7.1 Insolación Total
Uso de Energia Solar
Btu/h·ft2 (K·m2/W) en Superficie Horizontal, Tiempo de Sol
7
Ene. 21
40º Latitud N
0
(0)
8
9
10
11
12
1
2
3
4
28
83 127 154 164 154 127
83
28
(88) (262) (400) (485) (517) (485) (400) (262) (88)
5
0
(0)
Jul 21
114 174 225 265 290 298 290 265
225 174 114
(359) (548) (709) (835) (914) (939) (914) (835) (709) (548) (359)
Ene. 21
10
83 151 204 237 249 237 204
151
83
10
(32) (262) (476) (643) (747) (785) (747) (643) (476) (262) (32)
Jul 21
98
169 231 278 307 317 307 278
231 169 98
(309) (533) (728) (876) (968) (999) (968) (876) (728) (533) (309)
24º Latitud N
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
134
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
ti
ta
It
UL



07.fm Page 135 Thursday, March 3, 2016 12:44 PM
Uso de Energia Solar
135
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 7.2 (SI) Variación con Altitud Solar y Tiempo del Año para Irradiación Normal Directa
[2011A, Ch 35, Fig 4]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 7.2 (I-P) Variación con Altitud Solar y Tiempo del Año para Irradiación Normal Directa
[2011A, Ch 35, Fig 4]
Figura 7.3 (I-P) Irradiación Diaria Total para Superficies Horizontal, Inclinada y Vertical a 40°
Latitud Norte (± Figuras LAT son Grados de Inclinación por Encima o por Debajo de la Latitud)
[2011A, Ch 35, Fig 6]
136
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 7.3 (SI) Irradiación Diaria Total para Superficies Horizontal, Inclinada y Vertical a 40°
Latitud Norte (± Figuras LAT son Grados de Inclinación por Encima o por Debajo de la Latitud)
[2011A, Ch 35, Fig 6]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Uso de Energia Solar
07.fm Page 136 Thursday, March 3, 2016 12:44 PM
07.fm Page 137 Thursday, March 3, 2016 12:44 PM
Categoria*
Día Solar, Btu/ft2·día
2000 (Día Claro)
1500 (Levemente Nublado) 1000 (Día Nublado)
Sin esmalte
1600
1200
900
B
1000
700
400
C
400
200
—
D
—
—
—
E
—
—
—
A
1285
971
658
B
1128
815
533
C
908
595
282
D
407
157
—
E
—
—
—
A
1316
971
658
B
1191
877
564
C
1003
689
376
D
595
313
63
E
219
31
—
A
872
655
436
B
841
623
405
C
810
592
374
D
685
467
280
E
592
374
Uso de Energia Solar
Pintado
Ssuperficie Selectiva
Tubo Evacuado
156
Ti – Ta, °F
Aplicación
A
–9
Calefacción de piscina, clima cálido
B
9
Calefacción de piscina, clima fresco
C
36
Calentamiento de agua, clima cálido
D
90
Calentamiento de agua, clima fresco
E
144
Aire Acondicionado
*Categorías
*Derivada de Datos de Puntuación Solar y Corporación de Certificación (SRCC), www.solar-rating.org (Oct. 2006).
137
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
A
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 7.2 (I-P) Capacidades de Rendimiento Térmico* para Tipos Genéricos de
Colectores de Líquidos de Placa Plana [2012S, Ch 37, Tbl 3]
07.fm Page 138 Thursday, March 3, 2016 12:44 PM
Día Solar, MJ/m2·día
Categoría*
17.0 (Levemente Nublado)
11.4 (Día Nublado)
A
18.2
13.6
10.2
B
11.4
7.9
4.5
C
4.5
2.3
—
D
—
—
—
E
—
—
—
A
14.6
11.0
7.5
B
12.8
9.3
6.1
C
10.3
6.8
3.2
D
4.6
1.8
—
E
—
—
—
A
14.9
11.0
7.5
B
13.5
10.0
6.4
C
11.4
7.8
4.3
D
6.8
3.6
0.7
E
2.5
0.4
—
A
9.9
7.4
5.0
B
9.6
7.1
4.6
C
9.2
6.7
4.2
D
7.8
5.3
3.2
E
6.7
4.2
Uso de Energia Solar
Sin esmalte
Pintado
Superficie Selectiva
Tubo evacuado
1.8
Ti – Ta, °F
Aplicación
A
–5
Calefacción de piscina, clima cálido
B
5
Calefacción de piscina, clima fresco
C
20
Calentador de agua, clima cálido
D
50
Calentador de agua, clima fresco
E
80
Aire Acondicionado
*Categorías
*Derivada de Datos de Puntuación Solar y Corporación de Certificación (SRCC), www.solar-rating.org (Oct. 2006).
138
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
22.7 (Día Claro)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 7.2 (SI) Capacidades de Rendimiento Térmico* para Tipos Genéricos de
Colectores de Líquidos de Placa Plana [2012S, Ch 37, Tbl 3]
07.fm Page 139 Thursday, March 3, 2016 12:44 PM
Uso de Energia Solar
139
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 7.5 Aire Solar y Sistema de Calentamiento de Agua de Servicio [2011A, CH35, Fig 28]
(Adaptado de Beckman et al 1977)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 7.4 Sistema de Calefacción Solar de Base Líquida [2011A, Ch 35, Fig 28]
(Adaptado de Beckman et al. 1977)
Figura 7.6 Coleccion Solar, Almacenamiento y Sistema de Distribucion para Agua Caliente
Domestica y Espacio de Calentamiento [2011A, CH35, Fig25]
140
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 7.7 Calefaccion de locales y sistema de enfriamiento utilizando maquina de absorcion de
agua de bromuro de litio [2011A, Ch 35, Fig 26]
Colector de concentracion deseable, agua de temperatura >190°F (88°C)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Uso de Energia Solar
07.fm Page 140 Thursday, March 3, 2016 12:44 PM
08.fm Page 141 Thursday, March 3, 2016 2:58 PM
CICLOS DE REFRIGERACION
Los ciclos de refrigeración transfieren energía térmica de una región de temperatura baja TR a
un de temperatura alta. Generalmente la temperatura más alta del disipador de calor es el aire
ambiente o agua de refrigeración, a temperatura T0, la temperatura de los alrededores.
Las leyes primera y segunda de termodinámica pueden ser aplicadas a componentes individuales para determinar los balances de energía y masa y la irreversibilidad de los componentes.
Este procedimiento está ilustrado en secciones más adelante en este capítulo.
El rendimiento de un ciclo de refrigeración está usualmente descrito por un coeficiente de
rendimiento (COP), definido como el beneficio del ciclo (cantidad de calor removido) dividido
por la entrada de energía requerida para operar el ciclo:
COP =
Efecto de refrigeración útil
Energía neta suministrada desde sou externa
Para un sistema mecánico de compresión de vapor, la energía neta suministrada está generalmente en la forma de trabajo, mecánico o eléctrico, y puede incluir trabajo al compresor y ventiladores o bombas. De esta manera,
Q evap
COP = --------------W net
En un ciclo de refrigeración ´por absorción, la energía neta suministrada está usualmente en
la forma de calor en el generador y trabajo en las bombas y ventiladores, o
COP
 R = ---------------------- COP  rev
141
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
En muchos casos, el trabajo suministrado a un sistema de absorción es muy pequeño comparado a la cantidad de calor suministrado al generador, por eso el término trabajo es a menudo
descuidado.
Aplicando la segunda ley a un ciclo entero de refrigeración muestra que un ciclo completamente reversible operando bajo las mismas condiciones tiene el mismo coeficiente de rendimiento
(COP). La salida del actual ciclo de un ciclo reversible ideal está dada por la eficiencia de refrigeración:
Ciclos de Refrigeracion
Q evap
COP = ------------------------------Q gen + W net
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
8.
08.fm Page 142 Thursday, March 3, 2016 2:58 PM
Ciclos de Refrigeracion
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Calor en evaporador 4Q1 = m(h1 – h4) Btu/min [4Q1 = m(h1 – h4) – m(h1 – h2) kW]
Trabajo de compresión 1W2 = m(h2 – h1) con s = constante Btu/min (kW)
Calentar condensador 2Q3 = m(h2 – h3) Btu/min (kW)
Expansión por flujo de estrangulamiento h3 = h4
h1 – h4
4Q1
Coeficiente de rendimiento
COP = --------- = ---------------h2 – h1
1W 2
donde
m
=
tasa de flujo del refrigeramte, lb/min (kg/s)
h
=
entalpia, Btu/lb (kJ/kg)
s
=
entropía Btu/lb·°R (kJ/kg·K)
Desplazamiento del compresor teórico, D = m v1 ft3/min (m3/s)
donde v1 = volumen especifico en la aspiración, ft3/lb (m3/kg).
Para un ciclo dado, capacidad en tons (kW) de refrigeración:
 tons   200 Btu  min – ton 
m = ---------------------------------------------------------------------h1 – h4
(I-P)
kW
m = ----------------h1 – h4
(SI)
142
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 8.1 Ciclo de Refrigeración por Compresión de Vapor de una Etapa Teórica
08.fm Page 143 Thursday, March 3, 2016 2:58 PM
Ciclos de Refrigeracion
Figura 8.2 Esquemática de Expansión Directa, Real, Una Sola Etapa del Sistema de
Refrigeración Mecánico de Compresión a Vapor
[2013F, Ch 2, Fig 14]
143
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 8.3 Diagrama de Entalpia de Presión del Sistema Actual y el Sistema de Una Sola Etapa
Teórica que Opera Entre las Temperaturas de Aire de Entrada tR y t0 [2013F, Ch 2, Fig 15]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Hay caídas de presión en el evaporador, condensador y tubería. Hay potencia de entrada al
evaporador y condensador. Hay pérdidas y ganancias de calor entre el refrigerante y el medio
ambiente. El líquido es sub enfriado; el vapor de aspiración es sobrecalentado.
08.fm Page 144 Thursday, March 3, 2016 2:58 PM
Ciclos de Refrigeracion
La refrigeración por absorción utiliza calor como la principal entrada energética en vez de
energía mecánica o eléctrica para conducir el ciclo. El uso de calor de desecho puede hacer de la
refrigeración por absorción más económicamente atractiva.
El equipo puede ser categorizado ampliamente por si usa agua o amoniaco como refrigerante.
Los productos primarios en la categoría de refrigerante de agua son grandes enfriadores comerciales, los cuales utilizan bromuro de litio (LiBr) como absorbente. Hay tres productos primarios en
la categoría de refrigerante de amoníaco: (1) refrigeradoras domésticas, (2) enfriadores residenciales y (3) unidades grandes de refrigeración.
144
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 8.4 Similitudes Entre Sistemas de Compresión a Vapor y Absorción [2010R, Ch 18, Fig 1]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Refrigeración por Absorción
08.fm Page 145 Thursday, March 3, 2016 2:58 PM
Potencia eléctrica
0.01 a
0.04 kW/ton
100 a
1700 tons
Tabla 8.1 (SI) Características del Típico Calentamiento Indirecto,
Refrigerador de Agua de Absorción de Bromuro de Litio
Temperatura de entrada de
fluido caliente
Tasa de entrada de calor
(por kilovatio de
refrigeración
Temperatura de agua de
refrigeración
Flujo de agua de
refrigeración (por kilovatio
de refrigeración)
Temperatura de agua
refrigerada
Flujo de agua refrigerada
(por kilovatio de
refrigeración
Potencia eléctrica (por
kilovatio de refrigeración)
Capacidades nominales
Efecto Simple
60 to 80 kPa (calibre)
Efecto Doble
790 kPa (calibre)
1.48 a 1.51 kW
780 a 810 W
115 a 132°C, con tan bajo como 88°C
para algunas máquinas más pequeñas para
aplicaciones de calor de desecho
188°C
1.51 a 1.54 kW, con tan bajo como 1.43 kW
para algunas maquinas más pequeñas
0.83 kW
30°C
30°C
65 mL/s, con hasta 115 mL/s para
algunas máquinas más pequeñas
65 a 80 mL/s
6.7°C
7°C
43 mL/s, con 47 mL/s para algunas máquinas
internacionales más pequeñas
43 mL/s
3 a 11 W con un mínimo de 1 W para
algunas máquinas más pequeñas
180 a 5800 kW, con 18 a 35 kW para
algunas máquinas más pequeñas
3 a 11 W
350 a 6000 kW
145
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Presión de entrada de vapor
Consumo de vapor (por
kilovatio de refrigeración
Ciclos de Refrigeracion
Capacidades nominales
0.01 to 0.04 kW/ton con un mínimo de 0.004 kW/ton
para algunas máquinas más pequeñas
50 a 1660 tons, con 5 a 10 tons para
algunas máquinas más pequeñas
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 8.1 (I-P) Características del Típico Calentamiento Indirecto,
Refrigerador de Agua de Absorción de Bromuro de Litio
Simple Efecto
Doble Efecto
Presión de entrada de vapor
9 a 12 psig
115 psig
9.7 a
Consumo de vapor
18.3 a 18.7 lb/ton·h
10 lb/ton·h
240 a 270°F, con tan bajo como 190°F para
Temperatura de entrada de
algunas máquinas más pequeñas para
370°F
fluido caliente
aplicaciones de calor de desecho
18,100 to 18,500 Btu/ton·h, con tan bajo
Tasa de entrada de calor
como 17,100 Btu/ton·h para algunas
10,000 Btu/ton·h
máquinas más pequeñas
Temperatura de agua de
85°F
85°F
enfriamiento. in
Flujo de agua de
3.6 gpm/ton, con hasta 6.4 gpm/ton para
3.6 a
enfriamiento
algunas máquinas más pequeñas
4.5 gpm/ton
Temperatura de agua
44°F
44°F
refrigerada
2.4 gpm/ton, con 2.6 gpm/ton para
Flujo de agua refrigerada
2.4 gpm/ton
algunas máquinas internacionales más pequeñas
08.fm Page 146 Thursday, March 3, 2016 2:58 PM
Características de Rendimiento
Consumo de combustible (alto valor calorífico de combustible)
Coeficiente de rendimiento (COP) (alto valor calorífico)
Temperatura de agua de enfriamiento
Flujo de agua de enfriamiento
Temperatura de agua fría
Flujo de agua fría
Potencia eléctrica
Capacidades nominales
12,000 a 13,044 Btu/ton·h
0.92 a 1.0
85°F
4.4 a 4.5 gpm/ton
44°F
2.4 gpm/ton
0.01 a 0.04 kW/ton
100 a 1500 tons
Tabla 8.2 (SI) Características de Doble Efecto Típico, Calentamiento Directo,
Enfriador de Agua de Absorción de Bromuro de Litio
Ciclos de Refrigeracion
Características de Rendimiento
Consumo de combustible (alto valor calorífico de combustible)
(por kilovatio de refrigeración)
Coeficiente de rendimiento (COP) (alto valor calorífico)
Temperatura de agua de enfriamiento
Flujo de agua de enfriamiento (por kilovatio de refrigeración)
Temperatura de agua fría
Flujo de agua fría (por kilovatio de refrigeración)
Potencia eléctrica (por kilovatio de refrigeración)
Capacidades Nominales
1 a 1.1 kW
0.92 a 1.0
30°C
79 a 81 mL/s
7°C
43 mL/s
3 a 11 W
350 a 5300 kW
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
146
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 8.2 (I-P) Características de Doble Efecto Típico, Calentamiento Directo,
Enfriador de Agua de Absorción de Bromuro de Litio
09.fm Page 147 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
9.
REFRIGERANTES
Datos Refrigerantes
Tabla 9.1
Refrigerante
Datos Refrigerantes
Formula Química
Masa
Molecular
Punto de Ebullición
Grupo de
Normal
Seguridad
°C
°F
Hidrocarburos Halogenados
CFC (ya no se fabrican)
R-11
CCl3F
137.4
24
75
A1
R-12
CCl2F2
120.9
–30
–22
A1
R-113
CCl2FCClF2
167.4
48
118
A1
R-114
CClF2CClF2
170.9
4
38
A1
HCFC (descontinuado)
R-22
CHClF2
86.5
–41
–41
A1
R-123
CHCl2CF3
153.0
27
81
B1
HFCs
CH2F2
52.0
–52
–62
A2
R-125
CHF2CF3
120.0
–49
–56
A1
R-134a
CH2FCF3
102.0
–26
–15
A1
R-143a
CH3CF3
66.0
–47
–53
A2
CH3CH2CH3
44.0
–42
–44
A3
CH(CH3)2CH3
58.1
–12
11
A3
R-717 (ammonia)
NH3
17
–33
–28
B2
R-718 (water)
H2O
18
100
212
A1
(mix approx 79% N2, 21% O2)
29
CO2
44
–78
–109
A1
R-404A
(R-125, R-143a, R-134a)
(44/52/4)
97.6
–47
–52
A1
R-407C
(R-32, R-125, R-134a)
(23/25/52)
86.2
–43
–46
A1
R-410A
(R-32, R-125) (50/50)
72.6
–52
–61
A1
(R-125, R-143a) (50/50)
98.9
–46.7
–52.1
A1
Hidrocarburos
R-290 (propane)
R-600a
(isobutane)
Refrigerantes Naturales
R-744 (carbon
dioxide)
A1
Datos Refrigerantes
R-729 (air)
Mezclas Zeotrópicasc
Mezcla Azeotrópicac
R-507A
Lubricantes habituales:
1. Aceites minerales(MO)—CFCs, HCFCs
2. Bencenos de Alquilo (AB)—HCFCs
3. Ésteres de poliol (POE)—HCFCs, HFCs, mezclas
El efecto ambiental del cloro en CFCs y HCFCs ha resultado en que CFCs ya no se fabriquen
y que el fabricante de HCFCs sea eliminado.
147
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
R-32
09.fm Page 148 Thursday, March 3, 2016 12:46 PM
148
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.1 (I-P) Refrigerante 22 (Clorodifluormetano) Propiedades de Líquido Saturado y
Vapor Saturado [2013F, Ch 30, Fig 2]
09.fm Page 149 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
Refrigerante 22 (Clorodifluormetano) Propiedades de Líquido Saturado y
Vapor Saturado [2013F, Ch 30, Fig 2]
149
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.1 (SI)
09.fm Page 150 Thursday, March 3, 2016 12:46 PM
Densidad,
lb/ft3 Líquido
Volumen,
pie3/lb Vapor
0.263
0.436
0.698
1.082
1.629
2.388
2.865
3.417
4.053
4.782
5.615
6.561
7.631
8.836
10.190
11.703
13.390
14.696
15.262
17.336
19.624
22.142
24.906
27.929
31.230
34.824
38.728
42.960
47.536
52.475
57.795
63.514
69.651
76.225
83.255
90.761
98.763
107.28
116.33
125.94
136.13
146.92
158.33
170.38
183.09
196.50
210.61
225.46
241.06
257.45
274.65
292.69
311.58
331.37
352.08
373.74
396.38
420.04
444.75
470.56
497.50
525.62
554.98
585.63
617.64
651.12
686.20
723.74
98.28
97.36
96.44
95.52
94.59
93.66
93.19
92.71
92.24
91.76
91.28
90.79
90.31
89.82
89.33
88.83
88.33
87.97
87.82
87.32
86.80
86.29
85.76
85.24
84.71
84.17
83.63
83.08
82.52
81.96
81.39
80.82
80.24
79.65
79.05
78.44
77.83
77.20
76.57
75.92
75.27
74.60
73.92
73.23
72.52
71.80
71.06
70.30
69.52
68.72
67.90
67.05
66.18
65.27
64.32
63.34
62.31
61.22
60.07
58.84
57.53
56.10
54.52
52.74
50.67
48.14
44.68
32.70
146.06
90.759
58.384
38.745
26.444
18.511
15.623
13.258
11.309
9.6939
8.3487
7.2222
6.2744
5.4730
4.7924
4.2119
3.7147
3.4054
3.2872
2.9181
2.5984
2.3204
2.0778
1.8656
1.6792
1.5150
1.3701
1.2417
1.1276
1.0261
0.9354
0.8543
0.7815
0.7161
0.6572
0.6040
0.5558
0.5122
0.4725
0.4364
0.4035
0.3734
0.3459
0.3207
0.2975
0.2762
0.2566
0.2385
0.2217
0.2062
0.1918
0.1785
0.1660
0.1544
0.1435
0.1334
0.1238
0.1149
0.1064
0.0984
0.0907
0.0834
0.0764
0.0695
0.0626
0.0556
0.0479
0.0306
Datos Refrigerantes
Presión,
psia
–150
–140
–130
–120
–110
–100
–95
–90
–85
–80
–75
–70
–65
–60
–55
–50
–45
–41.46b
–40
–35
–30
–25
–20
–15
–10
–5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
205.06c
*Temperaturas en escala ITS-90
bPunto
Enthalpia, Btu/lb
Liquido
Vapor
–28.119
87.566
–25.583
88.729
–23.046
89.899
–20.509
91.074
–17.970
92.252
–15.427
93.430
–14.154
94.018
–12.880
94.605
–11.604
95.191
–10.326
95.775
–9.046
96.357
–7.763
96.937
–6.477
97.514
–5.189
98.087
–3.897
98.657
–2.602
99.224
–1.303
99.786
–0.381
100.181
0.000
100.343
1.308
100.896
2.620
101.443
3.937
101.984
5.260
102.519
6.588
103.048
7.923
103.570
9.263
104.085
10.610
104.591
11.964
105.090
13.325
105.580
14.694
106.061
16.070
106.532
17.455
106.994
18.848
107.445
20.250
107.884
21.662
108.313
23.083
108.729
24.514
109.132
25.956
109.521
27.409
109.897
28.874
110.257
30.350
110.602
31.839
110.929
33.342
111.239
34.859
111.530
36.391
111.801
37.938
112.050
39.502
112.276
41.084
112.478
42.686
112.653
44.308
112.799
45.952
112.914
47.621
112.996
49.316
113.040
51.041
113.043
52.798
113.000
54.591
112.907
56.425
112.756
58.305
112.539
60.240
112.247
62.237
111.866
64.309
111.378
66.474
110.760
68.757
109.976
71.196
108.972
73.859
107.654
76.875
105.835
80.593
103.010
91.208
91.208
de ebullición normal
Entropía, Btu/lby°F
Liquido
Vapor
–0.07757
0.29600
–0.06951
0.28808
–0.06170
0.28090
–0.05412
0.27439
–0.04675
0.26846
–0.03959
0.26307
–0.03608
0.26055
–0.03261
0.25815
–0.02918
0.25585
–0.02580
0.25366
–0.02245
0.25155
–0.01915
0.24954
–0.01587
0.24761
–0.01264
0.24577
–0.00943
0.24400
–0.00626
0.24230
–0.00311
0.24067
–0.00091
0.23955
0.00000
0.23910
0.00309
0.23759
0.00615
0.23615
0.00918
0.23475
0.01220
0.23341
0.01519
0.23211
0.01815
0.23086
0.02110
0.22965
0.02403
0.22848
0.02694
0.22735
0.02983
0.22625
0.03270
0.22519
0.03556
0.22415
0.03841
0.22315
0.04124
0.22217
0.04406
0.22121
0.04686
0.22028
0.04966
0.21936
0.05244
0.21847
0.05522
0.21758
0.05798
0.21672
0.06074
0.21586
0.06350
0.21501
0.06625
0.21417
0.06899
0.21333
0.07173
0.21250
0.07447
0.21166
0.07721
0.21083
0.07996
0.20998
0.08270
0.20913
0.08545
0.20827
0.08821
0.20739
0.09098
0.20649
0.09376
0.20557
0.09656
0.20462
0.09937
0.20364
0.10222
0.20261
0.10509
0.20153
0.10800
0.20040
0.11096
0.19919
0.11397
0.19790
0.11705
0.19650
0.12022
0.19497
0.12350
0.19328
0.12693
0.19136
0.13056
0.18916
0.13450
0.18651
0.13893
0.18316
0.14437
0.17835
0.16012
0.16012
cPunto
crítico
150
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,*
°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.2 (I-P) R-22 (Clorodifluormetano) Propiedades de Líquido Saturado y Vapor Saturado
[2013F, Ch 30, Tbl R-22]
09.fm Page 151 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.2 (SI) R-22 (Clorodifluormetano) Propiedades de Líquido Saturado y Vapor Saturado
[2013F, Ch 30, Tbl R-22]
*Temperaturas en escala ITS-90
Densidad,
kg/m3 Líquido
1571.3
1544.9
1518.2
1491.2
1463.7
1435.6
1429.9
1424.2
1418.4
1412.6
1409.2
1406.8
1401.0
1395.1
1389.1
1383.2
1377.2
1371.1
1365.0
1358.9
1352.7
1346.5
1340.3
1334.0
1327.6
1321.2
1314.7
1308.2
1301.6
1295.0
1288.3
1281.5
1274.7
1267.8
1260.8
1253.8
1246.7
1239.5
1232.2
1224.9
1217.4
1209.9
1202.3
1194.6
1186.7
1178.8
1170.7
1162.6
1154.3
1145.8
1137.3
1128.5
1119.6
1110.6
1101.4
1091.9
1082.3
1072.4
1062.3
1052.0
1041.3
1030.4
1001.4
969.7
934.4
893.7
844.8
780.1
662.9
523.8
Volumen,
m3/kg Vapor
8.26600
3.64480
1.77820
0.94342
0.53680
0.32385
0.29453
0.26837
0.24498
0.22402
0.21260
0.20521
0.18829
0.17304
0.15927
0.14682
0.13553
0.12528
0.11597
0.10749
0.09975
0.09268
0.08621
0.08029
0.07485
0.06986
0.06527
0.06103
0.05713
0.05352
0.05019
0.04710
0.04424
0.04159
0.03913
0.03683
0.03470
0.03271
0.03086
0.02912
0.02750
0.02599
0.02457
0.02324
0.02199
0.02082
0.01972
0.01869
0.01771
0.01679
0.01593
0.01511
0.01433
0.01360
0.01291
0.01226
0.01163
0.01104
0.01048
0.00995
0.00944
0.00896
0.00785
0.00685
0.00595
0.00512
0.00434
0.00356
0.00262
0.00191
Entalpia, kJ/kg
Líquido
90.71
101.32
111.94
122.58
133.27
144.03
146.19
148.36
150.53
152.70
154.00
154.89
157.07
159.27
161.47
163.67
165.88
168.10
170.33
172.56
174.80
177.04
179.30
181.56
183.83
186.11
188.40
190.70
193.01
195.33
197.66
200.00
202.35
204.71
207.09
209.47
211.87
214.28
216.70
219.14
221.59
224.06
226.54
229.04
231.55
234.08
236.62
239.19
241.77
244.38
247.00
249.65
252.32
255.01
257.73
260.47
263.25
266.05
268.89
271.76
274.66
277.61
285.18
293.10
301.46
310.44
320.38
332.09
349.56
366.90
bPunto de ebullición normal
Vapor
358.97
363.85
368.77
373.70
378.59
383.42
384.37
385.32
386.26
387.20
387.75
388.13
389.06
389.97
390.89
391.79
392.69
393.58
394.47
395.34
396.21
397.06
397.91
398.75
399.57
400.39
401.20
401.99
402.77
403.55
404.30
405.05
405.78
406.50
407.20
407.89
408.56
409.21
409.85
410.47
411.07
411.66
412.22
412.77
413.29
413.79
414.26
414.71
415.14
415.54
415.91
416.25
416.55
416.83
417.07
417.27
417.44
417.56
417.63
417.66
417.63
417.55
417.06
416.09
414.49
412.01
408.19
401.87
387.28
366.90
Entropía, kJ/(kgyK)
Liquido
0.5050
0.5646
0.6210
0.6747
0.7260
0.7752
0.7849
0.7944
0.8039
0.8134
0.8189
0.8227
0.8320
0.8413
0.8505
0.8596
0.8687
0.8778
0.8868
0.8957
0.9046
0.9135
0.9223
0.9311
0.9398
0.9485
0.9572
0.9658
0.9744
0.9830
0.9915
1.0000
1.0085
1.0169
1.0254
1.0338
1.0422
1.0505
1.0589
1.0672
1.0755
1.0838
1.0921
1.1004
1.1086
1.1169
1.1252
1.1334
1.1417
1.1499
1.1582
1.1665
1.1747
1.1830
1.1913
1.1997
1.2080
1.2164
1.2248
1.2333
1.2418
1.2504
1.2722
1.2945
1.3177
1.3423
1.3690
1.4001
1.4462
1.4927
Vapor
2.0543
1.9980
1.9508
1.9108
1.8770
1.8480
1.8428
1.8376
1.8327
1.8278
1.8250
1.8231
1.8186
1.8141
1.8098
1.8056
1.8015
1.7975
1.7937
1.7899
1.7862
1.7826
1.7791
1.7757
1.7723
1.7690
1.7658
1.7627
1.7596
1.7566
1.7536
1.7507
1.7478
1.7450
1.7422
1.7395
1.7368
1.7341
1.7315
1.7289
1.7263
1.7238
1.7212
1.7187
1.7162
1.7136
1.7111
1.7086
1.7061
1.7036
1.7010
1.6985
1.6959
1.6933
1.6906
1.6879
1.6852
1.6824
1.6795
1.6766
1.6736
1.6705
1.6622
1.6529
1.6424
1.6299
1.6142
1.5922
1.5486
1.4927
cPunto crítico
151
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
Presión,
MPa
0.00201
0.00481
0.01037
0.02047
0.03750
0.06453
0.07145
0.07894
0.08705
0.09580
0.10132
0.10523
0.11538
0.12628
0.13797
0.15050
0.16389
0.17819
0.19344
0.20968
0.22696
0.24531
0.26479
0.28543
0.30728
0.33038
0.35479
0.38054
0.40769
0.43628
0.46636
0.49799
0.53120
0.56605
0.60259
0.64088
0.68095
0.72286
0.76668
0.81244
0.86020
0.91002
0.96195
1.01600
1.07240
1.13090
1.19190
1.25520
1.32100
1.38920
1.46010
1.53360
1.60980
1.68870
1.77040
1.85510
1.94270
2.03330
2.12700
2.22390
2.32400
2.42750
2.70120
2.99740
3.31770
3.66380
4.03780
4.44230
4.88240
4.99000
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,*
°C
–100
–90
–80
–70
–60
–50
–48
–46
–44
–42
–40.81b
–40
–38
–36
–34
–32
–30
–28
–26
–24
–22
–20
–18
–16
–14
–12
–10
–8
–6
–4
–2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
65
70
75
80
85
90
95
96.15c
09.fm Page 152 Thursday, March 3, 2016 12:46 PM
Temp., °F
10
30
60
100
150
Temp., °F
30
60
100
150
Temp., °F
100
150
200
250
300
100
150
200
250
300
Temp., °F
150
200
250
300
Presión = 60 psia
Temp. Sat. = 21.94°F
V
h
s
0.9271
1.001
1.096
1.212
108.35
0.2271
113.17
0.2367
119.74
0.2488
128.19
0.2633
Presión = 90 psia
Temp. Sat. = 44.47°F
V
H
s
0.6401
0.7088
0.7906
111.69
0.2253
118.50
0.2379
127.18
0.2528
Presión = 180 psia
Temp. Sat. = 88.72°F
V
h
s
0.3177
114.29
0.2164
0.3678
123.90
0.2329
0.4132
133.45
0.2479
0.4558
143.10
0.2620
0.4965
152.93
0.2754
Presión = 220 psia
Temp. Sat. = 103.09°F
V
h
s
0.2900
0.3299
0.3666
0.4012
122.30
0.2263
132.20
0.2419
142.09
0.2564
152.10
0.2700
Presión = 260 psia
Temp. Sat. = 115.66°F
V
h
s
0.2356
120.58
0.2203
0.2720
130.90
0.2366
0.3046
141.06
0.2514
0.3351
151.27
0.2653
V = volumen de vapor, ft3/lb
h = entalpia, Btu/lb
s = entropía, Btu/lb °F
152
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Temp., °F
Presión = 30 psia
Temp. Sat. = 11.85°F
V
h
s
1.760
103.92
0.2325
1.943
109.92
0.2453
2.078
114.55
0.2545
2.255
120.92
0.2663
2.473
129.17
0.2804
Presión = 75 psia
Temp. Sat. = 34.06°F
V
h
s
0.7851
107.81
0.2229
0.7847
112.45
0.2306
0.8639
119.13
0.2429
0.9591
127.69
0.2576
Presión = 135 psia
Temp. Sat. = 69.39°F
V
h
s
0.4492
116.50
0.2260
0.5092
125.59
0.2416
0.5655
134.79
0.2561
0.6193
144.20
0.2698
0.6713
153.84
0.2829
Presión = 200 psia
Temp. Sat. = 96.17°F
V
h
s
0.2776
113.22
0.2126
0.3251
123.11
0.2295
0.3674
132.83
0.2448
0.4067
142.60
0.2591
0.4441
152.52
0.2726
Presión = 240 psia
Temp. Sat. = 109.57°F
V
h
s
0.2606
121.45
0.2232
0.2985
131.56
0.2392
0.3330
141.58
0.2538
0.3654
151.69
0.2676
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.3 (I-P) Vapor Sobrecalentado Propiedades Termodinámicas de R-22
09.fm Page 153 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.3 (SI) Vapor Sobrecalentado Propiedades Termodinámicas de R-22
Temp., °C
–20
– 10
0
10
20
40
60
Temp., °C
10
20
30
40
50
60
70
Temp., °C
20
40
60
80
100
120
140
Temp. °C
60
80
100
120
140
160
16.56
15.82
15.15
13.99
13.01
24.77
23.58
22.53
21.58
20.73
19.95
19.24
38.34
34.89
32.15
29.90
28.00
26.37
58.00
51.61
46.90
43.20
40.19
37.66
35.49
70.76
63.11
57.47
53.04
49.43
46.40
252.9
0.9569
259.5
0.9809
266.3
1.004
280.1
1.050
294.1
1.093
Presión = 600 kPa
Temp. Sat. = 5.84°C
265.1
0.9332
263.1
0.9576
270.2
0.9814
277.3
1.005
284.5
1.027
291.8
1.049
299.1
1.071
Presión = 1000 kPa
Temp. Sat. = 23.38°C
271.4
0.9416
286.8
0.9891
302.2
1.034
317.9
1.077
333.7
1.119
349.9
1.159
Presión = 1400 kPa
Temp. Sat. = 36.25°C
364.7
0.8930
281.3
0.9445
297.7
0.9922
314.0
1.037
330.4
1.080
346.9
1.121
363.7
1.161
Presión = 1800 kPa
Temp. Sat. = 46.65°C
275.2
0.9064
292.8
0.9575
309.9
1.005
326.9
1.049
343.9
1.091
361.1
1.132
Datos Refrigerantes
40
60
80
100
120
140
160

Presión = 400 kPa
Temp. Sat. = 6.57°C
h
s
 = densidad de vapor, kg/m3;
h = entalpia, kJ/kg
s = entropía, kJ/(kg·K)
153
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,°C
Presión= 200 kPa
Temp. Sat. = 25.20°C

h
s
8.647
243.8
0.9847
8.267
250.0
1.009
7.923
256.3
1.032
7.609
262.8
1.056
7.321
269.3
1.078
6.810
282.7
1.122
6.370
296.4
1.165
Presión = 500 kPa
Temp. Sat. = 0.11°C
20.19
257.8
0.9552
19.28
264.7
0.9791
19.46
271.7
1.002
17.73
278.7
1.025
17.06
285.8
1.048
16.44
293.0
1.069
15.87
300.2
1.091
Presión = 800 kPa
Temp. Sat. = 15.44°C
32.77
259.7
0.9214
29.67
274.5
0.9702
27.23
289.3
1.016
25.24
304.4
1.060
23.57
319.8
1.102
22.14
335.4
1.143
20.89
351.3
1.183
Presión = 1200 kPa
Temp. Sat. = 30.21°C
47.73
268.2
0.9163
43.00
284.1
0.9657
39.36
300.0
1.012
36.44
315.9
1.056
34.02
332.1
1.098
31.96
348.4
1.138
30.18
365.0
1.178
Presión = 1600 kPa
Temp. Sat. = 41.69°C
60.82
278.4
0.9249
54.80
295.3
0.9742
50.20
311.9
1.020
46.53
328.6
1.064
43.48
345.4
1.105
40.90
362.4
1.146
09.fm Page 154 Thursday, March 3, 2016 12:46 PM
154
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.2 (I-P) Diagrama Presión-Entalpia para Refrigerante 123 [2013F, Ch 30, Fig 5]
09.fm Page 155 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
155
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.2 (SI) Diagrama Presión-Entalpia para Refrigerante 123 [2013F, Ch 30, Fig 5]
09.fm Page 156 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
Volumen,
ft3/lb
Vapor
7431.6
3871.0
2111.6
1201.0
709.46
433.83
273.77
177.81
118.57
80.999
56.576
40.333
29.299
21.655
16.264
14.174
12.396
10.878
9.5779
8.4595
7.4943
6.6586
5.9327
5.3002
4.7474
4.2629
3.8371
3.4617
3.1301
2.8362
2.5753
2.4753
2.3429
2.1356
1.9503
1.7841
1.6349
1.5006
1.3795
1.2701
1.1710
1.0812
0.9996
0.9253
0.8577
0.7959
0.6876
0.5965
0.5195
0.4539
0.3979
0.3497
0.3080
0.2719
0.2404
0.2128
0.1885
0.1670
0.1479
0.1309
0.1155
0.1016
0.0889
0.0770
0.0658
0.0544
518.66
43.97
0.0403
362.63c
531.10
34.34
*Temperaturas en escala ITS-90
0.0291
Presión,
psia
–140
–130
–120
–110
–100
–90
–80
–70
–60
–50
–40
–30
–20
–10
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
82.08b
85
90
95
100
105
110
115
120
125
130
135
140
145
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
Entalpia, Btu/lb
b
Entropía, Btu/lb·°F
Liquido
Vapor
Liquido
Vapor
cp /cv
Vapor
–22.241
–20.033
–17.826
–15.619
–13.410
–11.195
–8.975
–6.746
–4.509
–2.260
0.000
2.272
4.558
6.857
9.170
10.332
11.498
12.667
13.840
15.017
16.198
17.382
18.570
19.762
20.958
22.158
23.362
24.570
25.782
26.998
28.218
28.728
29.443
30.671
31.904
33.141
34.383
35.628
36.879
38.134
39.393
40.657
41.926
43.200
44.479
45.763
48.347
50.953
53.583
56.237
58.918
61.627
64.367
67.141
69.952
72.805
75.704
78.655
81.666
84.749
87.916
91.188
94.594
98.186
102.059
106.459
71.783
72.974
74.187
75.421
76.676
77.950
79.244
80.556
81.885
83.231
84.592
85.967
87.355
88.754
90.163
90.871
91.582
92.294
93.008
93.723
94.440
95.158
95.877
96.597
97.317
98.038
98.760
99.481
100.203
100.924
101.645
101.945
102.365
103.085
103.804
104.521
105.238
105.953
106.666
107.377
108.086
108.792
109.497
110.198
110.896
111.591
112.970
114.333
115.678
117.001
118.300
119.572
120.813
122.019
123.184
124.303
125.367
126.368
127.294
128.128
128.851
129.431
129.822
129.950
129.670
128.628
–0.06050
–0.05370
–0.04710
–0.04070
–0.03447
–0.02840
–0.02247
–0.01668
–0.01101
–0.00545
0.00000
0.00535
0.01061
0.01578
0.02086
0.02337
0.02587
0.02834
0.03080
0.03324
0.03566
0.03806
0.04045
0.04282
0.04518
0.04752
0.04984
0.05215
0.05444
0.05673
0.05899
0.05993
0.06124
0.06348
0.06571
0.06792
0.07012
0.07231
0.07449
0.07665
0.07881
0.08095
0.08308
0.08520
0.08732
0.08942
0.09359
0.09773
0.10184
0.10592
0.10997
0.11400
0.11801
0.12201
0.12599
0.12997
0.13396
0.13795
0.14196
0.14600
0.15010
0.15426
0.15853
0.16297
0.16769
0.17298
0.23363
0.22843
0.22379
0.21966
0.21600
0.21275
0.20989
0.20737
0.20516
0.20323
0.20157
0.20014
0.19892
0.19790
0.19706
0.19670
0.19638
0.19609
0.19585
0.19563
0.19544
0.19529
0.19517
0.19507
0.19500
0.19495
0.19493
0.19493
0.19495
0.19499
0.19505
0.19508
0.19513
0.19522
0.19534
0.19546
0.19560
0.19576
0.19593
0.19611
0.19630
0.19650
0.19671
0.19693
0.19716
0.19739
0.19788
0.19839
0.19892
0.19945
0.19999
0.20053
0.20106
0.20158
0.20207
0.20254
0.20296
0.20334
0.20365
0.20387
0.20398
0.20395
0.20372
0.20320
0.20222
0.20036
1.1237
1.1212
1.1187
1.1165
1.1144
1.1124
1.1106
1.1090
1.1075
1.1061
1.1050
1.1040
1.1032
1.1026
1.1022
1.1021
1.1020
1.1020
1.1020
1.1021
1.1023
1.1025
1.1028
1.1031
1.1035
1.1040
1.1046
1.1052
1.1059
1.1067
1.1075
1.1079
1.1085
1.1095
1.1106
1.1119
1.1132
1.1146
1.1162
1.1178
1.1196
1.1215
1.1236
1.1258
1.1281
1.1306
1.1362
1.1426
1.1499
1.1583
1.1681
1.1793
1.1925
1.2079
1.2262
1.2482
1.2749
1.3079
1.3496
1.4035
1.4755
1.5762
1.7258
1.9693
2.4318
3.6383
112.667
125.064
0.18039
0.19551
118.800
118.800
Punto de ebullición normal
0.18779
0.18779
c

Punto crítico
156
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
0.003
0.006
0.011
0.020
0.036
0.060
0.097
0.154
0.236
0.354
0.519
0.744
1.046
1.445
1.963
2.274
2.625
3.019
3.460
3.952
4.499
5.106
5.778
6.519
7.334
8.229
9.208
10.278
11.445
12.713
14.090
14.696
15.580
17.192
18.931
20.804
22.819
24.980
27.297
29.776
32.425
35.251
38.261
41.464
44.868
48.479
56.360
65.173
74.986
85.868
97.892
111.13
125.66
141.56
158.91
177.80
198.31
220.53
244.58
270.54
298.53
328.69
361.16
396.11
433.76
474.41
Densidad,
lb/ft3
Líquido
108.90
108.12
107.35
106.57
105.80
105.03
104.26
103.48
102.70
101.92
101.13
100.34
99.54
98.73
97.92
97.51
97.10
96.69
96.28
95.86
95.44
95.02
94.60
94.17
93.74
93.31
92.88
92.44
92.01
91.56
91.12
90.94
90.67
90.22
89.77
89.31
88.85
88.39
87.92
87.45
86.98
86.50
86.01
85.52
85.03
84.53
83.52
82.49
81.43
80.34
79.23
78.08
76.89
75.66
74.38
73.04
71.64
70.16
68.60
66.92
65.11
63.12
60.91
58.37
55.33
51.32
Temp.,*
°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.4 (I-P) R-123 (2,2 Dicloro-1,1,1- Trifluoretano) Propiedades de Líquido
Saturado y Vapor Saturado [2013F, Ch 20, Tbl R-123]
09.fm Page 157 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.4 (SI) R-123 (2,2 Dicloro-1,1,1 Trifluoretano) Propiedades de Líquido
Saturado y Vapor Saturado [2013F, Ch 30, Tbl R-123]
Temp.,*
°C
Presión,
MPa
Densidad, kg/m3
Líquido
Vapor
123.92
335.98
133.17
341.25
142.46
346.66
151.81
352.21
161.25
357.88
170.78
363.65
180.41
369.52
190.15
375.45
200.00
381.44
201.98
382.64
203.97
383.84
205.97
385.05
207.96
386.25
209.97
387.46
211.97
388.66
213.99
389.87
216.00
391.08
218.02
392.29
220.05
393.49
222.08
394.70
224.12
395.91
226.16
397.12
228.03
398.22
228.21
398.32
230.26
399.53
232.31
400.73
234.38
401.93
236.44
403.14
238.51
404.34
240.59
405.54
242.67
406.73
244.76
407.93
246.86
409.12
248.95
410.31
251.06
411.50
253.17
412.69
255.28
413.87
257.41
415.05
259.53
416.23
261.67
417.40
263.81
418.57
265.95
419.73
268.10
420.89
270.26
422.05
272.42
423.20
274.60
424.35
276.77
425.50
278.96
426.63
281.15
427.77
283.35
428.89
285.55
430.01
287.77
431.13
289.99
432.23
292.22
433.33
294.45
434.43
296.70
435.51
298.95
436.59
301.21
437.66
303.49
438.72
305.77
439.77
317.32
444.88
329.15
449.67
341.32
454.07
353.92
457.94
367.10
461.05
381.13
463.01
396.61
462.89
416.22
456.82
437.39
437.39
bPunto de ebullición normal
Entropía, kJ/(kgyK)
Líquido
Vapor
0.6712
0.7179
0.7625
0.8054
0.8468
0.8868
0.9256
0.9633
1.0000
1.0072
1.0144
1.0216
1.0287
1.0358
1.0428
1.0499
1.0569
1.0638
1.0707
1.0776
1.0845
1.0913
1.0975
1.0981
1.1049
1.1116
1.1183
1.1250
1.1317
1.1383
1.1449
1.1515
1.1581
1.1646
1.1711
1.1776
1.1840
1.1905
1.1969
1.2033
1.2096
1.2160
1.2223
1.2286
1.2349
1.2411
1.2474
1.2536
1.2598
1.2660
1.2722
1.2783
1.2845
1.2906
1.2967
1.3028
1.3089
1.3150
1.3211
1.3271
1.3572
1.3872
1.4173
1.4475
1.4782
1.5101
1.5443
1.5867
1.6325
1.7691
1.7422
1.7206
1.7034
1.6901
1.6800
1.6726
1.6675
1.6642
1.6638
1.6634
1.6631
1.6628
1.6626
1.6625
1.6624
1.6623
1.6623
1.6624
1.6625
1.6626
1.6628
1.6630
1.6630
1.6633
1.6635
1.6639
1.6642
1.6646
1.6651
1.6655
1.6660
1.6665
1.6670
1.6676
1.6682
1.6688
1.6694
1.6701
1.6707
1.6714
1.6721
1.6728
1.6735
1.6743
1.6750
1.6758
1.6766
1.6774
1.6781
1.6789
1.6797
1.6806
1.6814
1.6822
1.6830
1.6838
1.6846
1.6854
1.6862
1.6902
1.6938
1.6969
1.6992
1.7003
1.6991
1.6939
1.6763
1.6325
cp /cv
Vapor
1.117
1.113
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.105
1.103
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.110
1.107
1.105
1.103
1.102
1.102
1.102
1.110
1.107
1.105
1.103
1.102
cPunto crítico
157
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
1709.6
1687.4
1665.1
1642.6
1620.0
1597.0
1573.8
1550.1
1526.1
1521.3
1516.4
1511.5
1506.6
1501.6
1496.7
1491.7
1486.7
1481.7
1476.6
1471.5
1466.4
1461.3
1456.6
1456.2
1451.0
1445.8
1440.6
1435.4
1430.1
1424.8
1419.4
1414.1
1408.7
1403.3
1397.8
1392.3
1386.8
1381.2
1375.6
1370.0
1364.3
1358.6
1352.8
1347.0
1341.2
1335.3
1329.3
1323.4
1317.3
1311.2
1305.1
1298.9
1292.6
1286.3
1279.9
1273.5
1266.9
1260.3
1253.7
1246.9
1211.9
1174.4
1133.6
1088.3
1036.8
975.7
896.9
765.9
550.0
Entalpia, kJ/kg
Líquido
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
–80
0.00013
–70
0.00034
–60
–50
0.00177
–40
0.00358
–30
0.00675
–20
0.01200
–10
0.02025
0
0.03265
2
0.03574
4
0.03907
6
0.04264
8
0.04647
10
0.05057
12
0.05495
14
0.05963
16
0.06463
18
0.06995
20
0.07561
22
0.08163
24
0.08802
26
0.09480
27.82b
0.10133
28
0.10198
30
0.10958
32
0.11762
34
0.12611
36
0.13507
38
0.14452
40
0.15447
42
0.16495
44
0.17597
46
0.18755
48
0.19971
50
0.21246
52
0.22584
54
0.23985
56
0.25451
58
0.26985
60
0.28589
62
0.30264
64
0.32013
66
0.33838
68
0.35740
70
0.37722
72
0.39787
74
0.41936
76
0.44171
78
0.46494
80
0.48909
82
0.51416
84
0.54019
86
0.56720
88
0.59520
90
0.62423
92
0.65430
94
0.68544
96
0.71768
98
0.75103
100
0.78553
110
0.97603
120
1.19900
130
1.45780
140
1.75630
150
2.09870
160
2.49010
170
2.93720
180
3.45060
c
183.68
3.66180
*Temperaturas en escala ITS-90
Volumen,
m3/kg
Vapor
83.6670
32.8420
14.3330
6.84600
3.53190
1.94700
1.13640
0.69690
0.44609
0.40991
0.37720
0.34759
0.32075
0.29637
0.27420
0.25401
0.23559
0.21877
0.20338
0.18929
0.17637
0.16451
0.15453
0.15360
0.14356
0.13431
0.12577
0.11789
0.11060
0.10385
0.09759
0.09179
0.08641
0.08140
0.07674
0.07240
0.06836
0.06458
0.06106
0.05777
0.05469
0.05180
0.04910
0.04656
0.04418
0.04195
0.03985
0.03787
0.03601
0.03426
0.03261
0.03105
0.02958
0.02819
0.02687
0.02563
0.02445
0.02334
0.02228
0.02128
0.01697
0.01361
0.01094
0.00879
0.00703
0.00555
0.00425
0.00292
0.00182
09.fm Page 158 Thursday, March 3, 2016 12:46 PM
158
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.3 (I-P) Diagrama de Presión-Entalpia para Refrigerante 134a [2013F, Ch 30, Fig.8]
09.fm Page 159 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
Diagrama de Presión-Entalpia para Refrigerante 134a [2013F, Ch 30, Fig.8]
159
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.3 (SI)
09.fm Page 160 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
Presión,
psia
–153.94a
0.057
0.072
0.129
0.221
0.365
0.583
0.903
1.359
1.993
2.392
2.854
3.389
4.002
4.703
5.501
6.406
7.427
8.576
9.862
11.299
12.898
14.671
14.696
16.632
18.794
21.171
23.777
26.628
29.739
33.124
36.800
40.784
45.092
49.741
54.749
60.134
65.913
72.105
78.729
85.805
93.351
101.39
109.93
119.01
128.65
138.85
149.65
161.07
173.14
185.86
199.28
213.41
228.28
243.92
260.36
277.61
295.73
314.73
334.65
355.53
377.41
400.34
424.36
449.52
475.91
503.59
532.68
563.35
588.75
–150
–140
–130
–120
–110
–100
–90
–80
–75
–70
–65
–60
–55
–50
–45
–40
–35
–30
–25
–20
–15
–14.93b
–10
–5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
205
210
213.91c
Densidad,
lb/ft3
Líquido
99.33
98.97
98.05
97.13
96.20
95.27
94.33
93.38
92.42
91.94
91.46
90.97
90.49
90.00
89.50
89.00
88.50
88.00
87.49
86.98
86.47
85.95
85.94
85.43
84.90
84.37
83.83
83.29
82.74
82.19
81.63
81.06
80.49
79.90
79.32
78.72
78.11
77.50
76.87
76.24
75.59
74.94
74.27
73.58
72.88
72.17
71.44
70.69
69.93
69.14
68.32
67.49
66.62
65.73
64.80
63.83
62.82
61.76
60.65
59.47
58.21
56.86
55.38
53.76
51.91
49.76
47.08
43.20
31.96
* Temperaturas en escala ITS-90
Volumen,
ft3/lb
Vapor
568.59
452.12
260.63
156.50
97.481
62.763
41.637
28.381
19.825
16.711
14.161
12.060
10.321
8.8733
7.6621
6.6438
5.7839
5.0544
4.4330
3.9014
3.4449
3.0514
3.0465
2.7109
2.4154
2.1579
1.9330
1.7357
1.5623
1.4094
1.2742
1.1543
1.0478
0.9528
0.8680
0.7920
0.7238
0.6625
0.6072
0.5572
0.5120
0.4710
0.4338
0.3999
0.3690
0.3407
0.3148
0.2911
0.2693
0.2493
0.2308
0.2137
0.1980
0.1833
0.1697
0.1571
0.1453
0.1343
0.1239
0.1142
0.1051
0.0964
0.0881
0.0801
0.0724
0.0647
0.0567
0.0477
0.0313
Entalpia, Btu/lb
Líquido
–32.992
–31.878
–29.046
–26.208
–23.360
–20.500
–17.626
–14.736
–11.829
–10.368
–8.903
–7.432
–5.957
–4.476
–2.989
–1.498
0.000
1.503
3.013
4.529
6.051
7.580
7.600
9.115
10.657
12.207
13.764
15.328
16.901
18.481
20.070
21.667
23.274
24.890
26.515
28.150
29.796
31.452
33.120
34.799
36.491
38.195
39.913
41.645
43.392
45.155
46.934
48.731
50.546
52.382
54.239
56.119
58.023
59.954
61.915
63.908
65.936
68.005
70.118
72.283
74.509
76.807
79.193
81.692
84.343
87.214
90.454
94.530
103.894
a̯ Punto triple
Vapor
80.362
80.907
82.304
83.725
85.168
86.629
88.107
89.599
91.103
91.858
92.614
93.372
94.131
94.890
95.650
96.409
97.167
97.924
98.679
99.433
100.184
100.932
100.942
101.677
102.419
103.156
103.889
104.617
105.339
106.056
106.767
107.471
108.167
108.856
109.537
110.209
110.871
111.524
112.165
112.796
113.414
114.019
114.610
115.186
115.746
116.289
116.813
117.317
117.799
118.258
118.690
119.095
119.468
119.807
120.108
120.366
120.576
120.731
120.823
120.842
120.773
120.598
120.294
119.822
119.123
118.097
116.526
113.746
103.894
Entropía, Btu/lby°F
Líquido
–0.09154
–0.08791
–0.07891
–0.07017
–0.06166
–0.05337
–0.04527
–0.03734
–0.02959
–0.02577
–0.02198
–0.01824
–0.01452
–0.01085
–0.00720
–0.00358
0.00000
0.00356
0.00708
0.01058
0.01406
0.01751
0.01755
0.02093
0.02433
0.02771
0.03107
0.03440
0.03772
0.04101
0.04429
0.04755
0.05079
0.05402
0.05724
0.06044
0.06362
0.06680
0.06996
0.07311
0.07626
0.07939
0.08252
0.08565
0.08877
0.09188
0.09500
0.09811
0.10123
0.10435
0.10748
0.11062
0.11376
0.11692
0.12010
0.12330
0.12653
0.12979
0.13309
0.13644
0.13985
0.14334
0.14693
0.15066
0.15459
0.15880
0.16353
0.16945
0.18320
b
Vapor
0.27923
0.27629
0.26941
0.26329
0.25784
0.25300
0.24871
0.24490
0.24152
0.23998
0.23854
0.23718
0.23590
0.23470
0.23358
0.23252
0.23153
0.23060
0.22973
0.22892
0.22816
0.22744
0.22743
0.22678
0.22615
0.22557
0.22502
0.22451
0.22403
0.22359
0.22317
0.22278
0.22241
0.22207
0.22174
0.22144
0.22115
0.22088
0.22062
0.22037
0.22013
0.21989
0.21966
0.21944
0.21921
0.21898
0.21875
0.21851
0.21826
0.21800
0.21772
0.21742
0.21709
0.21673
0.21634
0.21591
0.21542
0.21488
0.21426
0.21356
0.21274
0.21180
0.21069
0.20935
0.20771
0.20562
0.20275
0.19814
0.18320
Calor Específico cp
Btu/lby°F
Líquido
Vapor
0.2829
0.1399
0.2830
0.1411
0.2834
0.1443
0.2842
0.1475
0.2853
0.1508
0.2866
0.1540
0.2881
0.1573
0.2898
0.1607
0.2916
0.1641
0.2925
0.1658
0.2935
0.1676
0.2945
0.1694
0.2955
0.1713
0.2965
0.1731
0.2976
0.1751
0.2987
0.1770
0.2999
0.1790
0.3010
0.1811
0.3022
0.1832
0.3035
0.1853
0.3047
0.1875
0.3060
0.1898
0.3061
0.1898
0.3074
0.1921
0.3088
0.1945
0.3102
0.1969
0.3117
0.1995
0.3132
0.2021
0.3147
0.2047
0.3164
0.2075
0.3181
0.2103
0.3198
0.2132
0.3216
0.2163
0.3235
0.2194
0.3255
0.2226
0.3275
0.2260
0.3297
0.2294
0.3319
0.2331
0.3343
0.2368
0.3368
0.2408
0.3394
0.2449
0.3422
0.2492
0.3451
0.2537
0.3482
0.2585
0.3515
0.2636
0.3551
0.2690
0.3589
0.2747
0.3630
0.2809
0.3675
0.2875
0.3723
0.2948
0.3775
0.3026
0.3833
0.3112
0.3897
0.3208
0.3968
0.3315
0.4048
0.3435
0.4138
0.3571
0.4242
0.3729
0.4362
0.3914
0.4504
0.4133
0.4675
0.4400
0.4887
0.4733
0.5156
0.5159
0.5512
0.5729
0.6012
0.6532
0.6768
0.7751
0.8062
0.9835
1.0830
1.4250
2.1130
3.0080


Punto de ebullición normal
cp /cv
Vapor
1.1637
1.1623
1.1589
1.1559
1.1532
1.1509
1.1490
1.1475
1.1465
1.1462
1.1460
1.1459
1.1460
1.1462
1.1466
1.1471
1.1478
1.1486
1.1496
1.1508
1.1521
1.1537
1.1537
1.1554
1.1573
1.1595
1.1619
1.1645
1.1674
1.1705
1.1740
1.1777
1.1818
1.1862
1.1910
1.1961
1.2018
1.2079
1.2145
1.2217
1.2296
1.2382
1.2475
1.2578
1.2690
1.2813
1.2950
1.3101
1.3268
1.3456
1.3666
1.3903
1.4173
1.4481
1.4837
1.5250
1.5738
1.6318
1.7022
1.7889
1.8984
2.0405
2.2321
2.5041
2.9192
3.6309
5.1360

c
Punto crítico
160
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,*
°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.5 (I-P) R-134a (1,1,1,2 Tetrafluoretano) Propiedades de Líquido Saturado y
Vapor Saturado [2013F, Ch 30, Tbl R-134a]
09.fm Page 161 Thursday, March 3, 2016 12:46 PM
–103.30a
–100
–90
–80
–70
–60
–50
–40
–30
–28
–26.07b
–26
–24
–22
–20
–18
–16
–14
–12
–10
–8
–6
–4
–2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
85
90
95
100
101.06c
0.00039
0.00056
0.00152
0.00367
0.00798
0.01591
0.02945
0.05121
0.08438
0.09270
0.10133
0.10167
0.11130
0.12165
0.13273
0.14460
0.15728
0.17082
0.18524
0.20060
0.21693
0.23428
0.25268
0.27217
0.29280
0.31462
0.33766
0.36198
0.38761
0.41461
0.44301
0.47288
0.50425
0.53718
0.57171
0.60789
0.64578
0.68543
0.72688
0.77020
0.81543
0.86263
0.91185
0.96315
1.0166
1.0722
1.1301
1.1903
1.2529
1.3179
1.3854
1.4555
1.5282
1.6036
1.6818
1.7628
1.8467
1.9337
2.0237
2.1168
2.2132
2.3130
2.4161
2.5228
2.6332
2.9258
3.2442
3.5912
3.9724
4.0593
* Temperaturas en escala ITS-90
Densidad,
kg/m3
Líquido
1591.1
1582.4
1555.8
1529.0
1501.9
1474.3
1446.3
1417.7
1388.4
1382.4
1376.7
1376.5
1370.4
1364.4
1358.3
1352.1
1345.9
1339.7
1333.4
1327.1
1320.8
1314.3
1307.9
1301.4
1294.8
1288.1
1281.4
1274.7
1267.9
1261.0
1254.0
1246.9
1239.8
1232.6
1225.3
1218.0
1210.5
1202.9
1195.2
1187.5
1179.6
1171.6
1163.4
1155.1
1146.7
1138.2
1129.5
1120.6
1111.5
1102.3
1092.9
1083.2
1073.4
1063.2
1052.9
1042.2
1031.2
1020.0
1008.3
996.2
983.8
970.8
957.3
943.1
928.2
887.2
837.8
772.7
651.2
511.9
Volumen,
m3/kg
Vapor
35.4960
25.1930
9.7698
4.2682
2.0590
1.0790
0.60620
0.36108
0.22594
0.20680
0.19018
0.18958
0.17407
0.16006
0.14739
0.13592
0.12551
0.11605
0.10744
0.09959
0.09242
0.08587
0.07987
0.07436
0.06931
0.06466
0.06039
0.05644
0.05280
0.04944
0.04633
0.04345
0.04078
0.03830
0.03600
0.03385
0.03186
0.03000
0.02826
0.02664
0.02513
0.02371
0.02238
0.02113
0.01997
0.01887
0.01784
0.01687
0.01595
0.01509
0.01428
0.01351
0.01278
0.01209
0.01144
0.01083
0.01024
0.00969
0.00916
0.00865
0.00817
0.00771
0.00727
0.00685
0.00645
0.00550
0.00461
0.00374
0.00268
0.00195
Entalpia, kJ/kg
Entropía, kJ/(kgyK)
Líquido
Vapor
Líquido
Vapor
cp /cv
Vapor
71.46
75.36
87.23
99.16
111.20
123.36
135.67
148.14
160.79
163.34
165.81
165.90
168.47
171.05
173.64
176.23
178.83
181.44
184.07
186.70
189.34
191.99
194.65
197.32
200.00
202.69
205.40
208.11
210.84
213.58
216.33
219.09
221.87
224.66
227.47
230.29
233.12
235.97
238.84
241.72
244.62
247.54
250.48
253.43
256.41
259.41
262.43
265.47
268.53
271.62
274.74
277.89
281.06
284.27
287.50
290.78
294.09
297.44
300.84
304.28
307.78
311.33
314.94
318.63
322.39
332.22
342.93
355.25
373.30
389.64
334.94
336.85
342.76
348.83
355.02
361.31
367.65
374.00
380.32
381.57
382.78
382.82
384.07
385.32
386.55
387.79
389.02
390.24
391.46
392.66
393.87
395.06
396.25
397.43
398.60
399.77
400.92
402.06
403.20
404.32
405.43
406.53
407.61
408.69
409.75
410.79
411.82
412.84
413.84
414.82
415.78
416.72
417.65
418.55
419.43
420.28
421.11
421.92
422.69
423.44
424.15
424.83
425.47
426.07
426.63
427.14
427.61
428.02
428.36
428.65
428.86
429.00
429.04
428.98
428.81
427.76
425.42
420.67
407.68
389.64
0.4126
0.4354
0.5020
0.5654
0.6262
0.6846
0.7410
0.7956
0.8486
0.8591
0.8690
0.8694
0.8798
0.8900
0.9002
0.9104
0.9205
0.9306
0.9407
0.9506
0.9606
0.9705
0.9804
0.9902
1.0000
1.0098
1.0195
1.0292
1.0388
1.0485
1.0581
1.0677
1.0772
1.0867
1.0962
1.1057
1.1152
1.1246
1.1341
1.1435
1.1529
1.1623
1.1717
1.1811
1.1905
1.1999
1.2092
1.2186
1.2280
1.2375
1.2469
1.2563
1.2658
1.2753
1.2848
1.2944
1.3040
1.3137
1.3234
1.3332
1.3430
1.3530
1.3631
1.3733
1.3836
1.4104
1.4390
1.4715
1.5188
1.5621
1.9639
1.9456
1.8972
1.8580
1.8264
1.8010
1.7806
1.7643
1.7515
1.7492
1.7472
1.7471
1.7451
1.7432
1.7413
1.7396
1.7379
1.7363
1.7348
1.7334
1.7320
1.7307
1.7294
1.7282
1.7271
1.7260
1.7250
1.7240
1.7230
1.7221
1.7212
1.7204
1.7196
1.7188
1.7180
1.7173
1.7166
1.7159
1.7152
1.7145
1.7138
1.7131
1.7124
1.7118
1.7111
1.7103
1.7096
1.7089
1.7081
1.7072
1.7064
1.7055
1.7045
1.7035
1.7024
1.7013
1.7000
1.6987
1.6972
1.6956
1.6939
1.6920
1.6899
1.6876
1.6850
1.6771
1.6662
1.6492
1.6109
1.5621
1.164
1.162
1.156
1.151
1.148
1.146
1.146
1.148
1.152
1.153
1.154
1.154
1.155
1.156
1.158
1.159
1.161
1.163
1.165
1.167
1.169
1.171
1.174
1.176
1.179
1.182
1.185
1.189
1.192
1.196
1.200
1.204
1.209
1.214
1.219
1.224
1.230
1.236
1.243
1.249
1.257
1.265
1.273
1.282
1.292
1.303
1.314
1.326
1.339
1.354
1.369
1.386
1.405
1.425
1.448
1.473
1.501
1.532
1.567
1.607
1.653
1.705
1.766
1.838
1.924
2.232
2.820
4.369
20.81

a̯Punto triple
b
Punto de ebullición normal
c
Punto crítico
161
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
Presión,
MPa
R-134a (1,1,1,2- Tetrafluoretano) Propiedades de Líquido Saturado
y Vapor Saturado [2013F, Ch 30, Tbl R-134a]
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,*
°C
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.5 (SI)
09.fm Page 162 Thursday, March 3, 2016 12:46 PM
Presión =
15 psia
Temp. Sat. = 14.25°F
Temp, °F
V
h
s
0
3.118
103.35
0.2324
V
h
s
20
3.268
107.07
40
3.417
110.88
0.2403
1.584
106.18
0.2255
0.2481
1.663
110.06
60
3.565
0.2335
114.79
0.2558
1.741
114.03
80
0.2413
3.712
118.79
0.2633
1.818
118.08
0.2489
100
3.858
122.87
0.2708
1.895
122.22
0.2564
120
4.004
127.05
0.2781
1.971
126.44
0.2638
140
4.149
131.31
0.2853
2.046
130.75
0.2711
Presión =
45 psia
Temp. Sat. = 34.94°F
Temp, °F
Presión =
60 psia
Temp. Sat. = 49.94°F
V
h
s
40
1.077
109.20
0.2243
V
h
s
60
1.132
113.24
80
1.187
117.36
0.2323
0.8269
112.41
0.2255
0.2400
0.8699
116.60
100
1.240
0.2334
121.55
0.2477
0.9120
120.86
0.2412
120
140
1.293
125.82
0.2552
0.9533
125.18
0.2488
1.345
130.17
0.2625
0.9940
129.58
0.2562
Presión =
150 psia
Temp. Sat. = 105.14°F
Temp, °F
Presión =
200 psia
Temp. Sat. = 125.19°F
V
h
s
125
0.3433
122.06
0.2274
V
h
s
150
0.3692
128.08
175
0.3937
134.13
0.2375
0.2596
125.69
0.2289
0.2472
0.2807
132.07
200
0.4171
0.2391
140.23
0.2566
0.3003
138.42
225
0.2489
0.4397
146.41
0.2658
0.3189
144.80
250
0.2584
0.4616
152.66
0.2748
0.3366
151.23
0.2676
Presión = 250 psia
Temp. Sat. = 141.79°F
Temp, °F
Presión = 300 psia
Temp. Sat. = 156.07°F
V
h
s
150
0.1920
122.93
0.2210
V
h
s
175
0.2118
129.79
200
0.2295
136.47
0.2320
0.1646
127.20
0.2252
0.2423
0.1817
134.35
225
0.2460
0.2362
143.10
0.2522
0.1969
141.29
250
0.2466
0.2614
149.73
0.2617
0.2110
148.15
0.2564
275
0.2761
156.37
0.2709
0.2242
154.99
0.2659
300
0.2902
163.07
0.2798
0.2367
161.84
0.2750
V = volume de vapr, ft3/lb
h = entalpia, Btu/lb
s = entropía, Btu/lb·°F
162
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Presión =
30 psia
Temp. Sat. = 15.39°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.6 (I-P) Vapor Sobrecalentado Propiedades Termodinámicas de R-134a
09.fm Page 163 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.6 (SI) Vapor Sobrecalentado Propiedades Termodinámicas de R-134a
Temp,
°F
0
20
40
60
80
100
120
140
Temp,
°F
40
60
80
100
120
140
Temp,
°F
150
175
200
225
250
275
300
V
1.584
1.663
1.741
1.818
1.895
1.971
2.046
106.18
110.06
114.03
118.08
122.22
126.44
130.75
V
Presión = 60 psia
Temp. Sat. = 49.94°F
h
Presión = 45 psia
Temp. Sat. = 34.94°F
V
h
s
1.077
109.20
0.2243
1.132
113.24
0.2323
1.187
117.36
0.2400
1.240
121.55
0.2477
1.293
125.82
0.2552
1.345
130.17
0.2625
Presión = 150 psia
Temp. Sat. = 105.14°F
V
h
s
0.3433
122.06
0.2274
0.3692
128.08
0.2375
0.3937
134.13
0.2472
0.4171
140.23
0.2566
0.4397
146.41
0.2658
0.4616
152.66
0.2748
Presión = 250 psia
Temp. Sat. = 141.79°F
V
h
s
0.1920
122.93
0.2210
0.2118
129.79
0.2320
0.2295
136.47
0.2423
0.2460
143.10
0.2522
0.2614
149.73
0.2617
0.2761
156.37
0.2709
0.2902
163.07
0.2798
0.8269
0.8699
0.9120
0.9533
0.9940
112.41
116.60
120.86
125.18
129.58
s
0.2255
0.2335
0.2413
0.2489
0.2564
0.2638
0.2711
s
0.2255
0.2334
0.2412
0.2488
0.2562
Presión = 200 psia
Temp. Sat. = 125.19°F
V
h
s
0.2596
0.2807
0.3003
0.3189
0.3366
125.69
132.07
138.42
144.80
151.23
0.2289
0.2391
0.2489
0.2584
0.2676
Datos Refrigerantes
Temp,
°F
Presión = 30 psia
Temp. Sat. = 15.39°F
h
Presión = 300 psia
Temp. Sat. = 156.07°F
V
h
s
0.1646
0.1817
0.1969
0.2110
0.2242
0.2367
127.20
134.35
141.29
148.15
154.99
161.84
0.2252
0.2362
0.2466
0.2564
0.2659
0.2750
V = volume de vapr, ft3/lb
h = entalpia, Btu/lb
s = entropía, Btu/lb·°F
163
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
125
150
175
200
225
250
Presión = 15 psia
Temp. Sat. = 14.25°F
V
h
s
3.118
103.35
0.2324
3.268
107.07
0.2403
3.417
110.88
0.2481
3.565
114.79
0.2558
3.712
118.79
0.2633
3.858
122.87
0.2708
4.004
127.05
0.2781
4.149
131.31
0.2853
09.fm Page 164 Thursday, March 3, 2016 12:46 PM
164
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.4 (I-P) Diagrama Presión-Entalpia para Refrigerante 717 (Amoniaco) [2013F, Ch 30, Fig. 18]
09.fm Page 165 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
165
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.4 (SI) Diagrama Presión-Entalpia para Refrigerante 717 (Amoniaco) [2013F, Ch 30, Fig. 18]
09.fm Page 166 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
Presión,
psia
Calor Esprcifico cp,
cp /cv
Btu/lby°F
Vapor
Líquido
Vapor
Líquido
Vapor
–0.18124
1.63351
1.0044
0.4930
1.3252
–0.15922
1.60421
1.0100
0.4959
1.3262
–0.13142
1.56886
1.0176
0.5003
1.3278
–0.10416
1.53587
1.0254
0.5056
1.3296
–0.07741
1.50503
1.0331
0.5118
1.3319
–0.05114
1.47614
1.0406
0.5190
1.3346
–0.02534
1.44900
1.0478
0.5271
1.3379
0.00000
1.42347
1.0549
0.5364
1.3419
0.02491
1.39938
1.0617
0.5467
1.3465
0.02987
1.39470
1.0631
0.5490
1.3475
0.03720
1.38784
1.0651
0.5524
1.3491
0.04939
1.37660
1.0684
0.5583
1.3520
0.06148
1.36567
1.0716
0.5646
1.3550
0.07347
1.35502
1.0749
0.5711
1.3584
0.08536
1.34463
1.0782
0.5781
1.3619
0.09715
1.33450
1.0814
0.5853
1.3657
0.10885
1.32462
1.0847
0.5929
1.3698
0.12045
1.31496
1.0880
0.6009
1.3742
0.13197
1.30552
1.0914
0.6092
1.3789
0.14340
1.29629
1.0948
0.6179
1.3840
0.15474
1.28726
1.0983
0.6271
1.3894
0.16599
1.27842
1.1019
0.6366
1.3951
0.17717
1.26975
1.1056
0.6465
1.4012
0.18827
1.26125
1.1094
0.6569
1.4078
0.19929
1.25291
1.1134
0.6678
1.4147
0.21024
1.24472
1.1175
0.6791
1.4222
0.22111
1.23667
1.1218
0.6909
1.4301
0.23192
1.22875
1.126
0.703
1.438
0.24266
1.22095
1.131
0.716
1.447
0.25334
1.21327
1.136
0.730
1.457
0.26396
1.20570
1.141
0.744
1.467
0.27452
1.19823
1.147
0.758
1.478
0.28503
1.19085
1.153
0.774
1.490
0.29549
1.18356
1.159
0.790
1.502
0.30590
1.17634
1.166
0.807
1.515
0.31626
1.16920
1.173
0.824
1.529
0.32659
1.16211
1.180
0.843
1.544
0.33688
1.15508
1.188
0.862
1.561
0.34713
1.14809
1.197
0.883
1.578
0.35736
1.14115
1.206
0.905
1.597
0.36757
1.13423
1.216
0.928
1.617
0.37775
1.12733
1.227
0.952
1.638
0.38792
1.12044
1.239
0.978
1.662
0.39808
1.11356
1.251
1.006
1.687
0.40824
1.10666
1.265
1.035
1.715
0.41840
1.09975
1.280
1.067
1.745
0.42857
1.09281
1.296
1.101
1.778
0.43875
1.08582
1.313
1.138
1.813
0.44896
1.07878
1.333
1.178
1.853
0.45919
1.07167
1.354
1.222
1.896
0.46947
1.06447
1.377
1.270
1.944
0.47980
1.05717
1.403
1.322
1.998
0.49019
1.04974
1.432
1.381
2.058
0.50066
1.04217
1.465
1.446
2.126
0.51121
1.03443
1.502
1.519
2.203
0.52188
1.02649
1.543
1.602
2.290
0.53267
1.01831
1.591
1.697
2.392
0.54360
1.00986
1.646
1.806
2.509
0.55472
1.00109
1.711
1.935
2.648
0.56605
0.99193
1.788
2.088
2.814
0.57763
0.98232
1.882
2.272
3.015
0.58953
0.97216
1.999
2.501
3.265
0.60182
0.96133
2.148
2.790
3.582
0.61462
0.94966
2.346
3.171
4.000
0.62809
0.93690
2.624
3.693
4.575
0.64249
0.92269
3.047
4.460
5.420
0.67662
0.88671
5.273
8.106
9.439
0.78093
0.78093



b Punto de ebullición normal
c Punto Crítico
Entropía, Btu/lby°F
166
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Densidad, lb/ Volumen, ft3/
Entropia, Btu/lb
ft3
lb
Líquido
Vapor
Líquido
Vapor
–107.78a
0.883
45.75
249.92
–69.830
568.765
–100
1.237
45.47
182.19
–61.994
572.260
–90
1.864
45.09
124.12
–51.854
576.688
–80
2.739
44.71
86.546
–41.637
581.035
–70
3.937
44.31
61.647
–31.341
585.288
–60
5.544
43.91
44.774
–20.969
589.439
–50
7.659
43.50
33.105
–10.521
593.476
–40
10.398
43.08
24.881
0.000
597.387
–30
13.890
42.66
18.983
10.592
601.162
–27.99b
14.696
42.57
18.007
12.732
601.904
–25
15.962
42.45
16.668
15.914
602.995
–20
18.279
42.23
14.684
21.253
604.789
–15
20.858
42.01
12.976
26.609
606.544
–10
23.723
41.79
11.502
31.982
608.257
–5
26.895
41.57
10.226
37.372
609.928
0
30.397
41.34
9.1159
42.779
611.554
5
34.253
41.12
8.1483
48.203
613.135
10
38.487
40.89
7.3020
53.644
614.669
15
43.126
40.66
6.5597
59.103
616.154
20
48.194
40.43
5.9067
64.579
617.590
25
53.720
40.20
5.3307
70.072
618.974
30
59.730
39.96
4.8213
75.585
620.305
35
66.255
39.72
4.3695
81.116
621.582
40
73.322
39.48
3.9680
86.666
622.803
45
80.962
39.24
3.6102
92.237
623.967
50
89.205
38.99
3.2906
97.828
625.072
55
98.083
38.75
3.0045
103.441
626.115
60
107.63
38.50
2.7479
109.076
627.097
65
117.87
38.25
2.5172
114.734
628.013
70
128.85
37.99
2.3094
120.417
628.864
75
140.59
37.73
2.1217
126.126
629.647
80
153.13
37.47
1.9521
131.861
630.359
85
166.51
37.21
1.7983
137.624
630.999
90
180.76
36.94
1.6588
143.417
631.564
95
195.91
36.67
1.5319
149.241
632.052
100
212.01
36.40
1.4163
155.098
632.460
105
229.09
36.12
1.3108
160.990
632.785
110
247.19
35.83
1.2144
166.919
633.025
115
266.34
35.55
1.1262
172.887
633.175
120
286.60
35.26
1.0452
178.896
633.232
125
307.98
34.96
0.9710
184.949
633.193
130
330.54
34.66
0.9026
191.049
633.053
135
354.32
34.35
0.8397
197.199
632.807
140
379.36
34.04
0.7817
203.403
632.451
145
405.70
33.72
0.7280
209.663
631.978
150
433.38
33.39
0.6785
215.984
631.383
155
462.45
33.06
0.6325
222.370
630.659
160
492.95
32.72
0.5899
228.827
629.798
165
524.94
32.37
0.5504
235.359
628.791
170
558.45
32.01
0.5136
241.973
627.630
175
593.53
31.64
0.4793
248.675
626.302
180
630.24
31.26
0.4473
255.472
624.797
185
668.63
30.87
0.4174
262.374
623.100
190
708.74
30.47
0.3895
269.390
621.195
195
750.64
30.05
0.3633
276.530
619.064
200
794.38
29.62
0.3387
283.809
616.686
205
840.03
29.17
0.3156
291.240
614.035
210
887.64
28.70
0.2938
298.842
611.081
215
937.28
28.21
0.2733
306.637
607.788
220
989.03
27.69
0.2538
314.651
604.112
225
1042.96
27.15
0.2354
322.918
599.996
230
1099.14
26.57
0.2178
331.483
595.371
235
1157.69
25.95
0.2010
340.404
590.142
240
1218.68
25.28
0.1849
349.766
584.183
245
1282.24
24.55
0.1693
359.695
577.309
250
1348.49
23.72
0.1540
370.391
569.240
260
1489.71
21.60
0.1233
395.943
547.139
c
270.05
1643.71
14.05
0.0712
473.253
473.253
a̯Punto triple
*Temperaturas en escala ITS-90
Temp.,*
°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.7 (I-P) R-717 (Amoniaco) Propiedades de Líquido Saturado y Vapor
Saturado [2013F, Ch 30, Tbl R-717]
09.fm Page 167 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.7 (SI) R-717 (Amoniaco) Propiedades de Líquido Saturado y Vapor
Saturado [2013F, Ch 30, Tbl R-717]
a
Presión,
MPa
Entalpia, kJ/kg
Liquido
–143.15
–110.81
–68.06
–24.73
19.17
28.01
36.88
45.77
48.76
54.67
63.60
72.55
81.52
90.51
99.52
108.55
117.60
126.67
135.76
144.88
154.01
163.16
172.34
181.54
190.76
200.00
209.27
218.55
227.87
237.20
246.57
255.95
265.37
274.81
284.28
293.78
303.31
312.87
322.47
332.09
341.76
351.45
361.19
370.96
380.78
390.64
400.54
410.48
420.48
430.52
440.62
466.10
491.97
518.26
545.04
572.37
600.34
629.04
658.61
689.19
721.00
754.35
789.68
827.74
869.92
919.68
992.02
1119.22
Vapor
Entropía, kJ/(kgyK)
Liquido
1341.23
–0.4716
1355.55
–0.3094
1373.73
–0.1040
1391.19
0.0945
1407.76
0.2867
1410.96
0.3245
1414.11
0.3619
1417.23
0.3992
1418.26
0.4117
1420.29
0.4362
1423.31
0.4730
1426.28
0.5096
1429.21
0.5460
1432.08
0.5821
1434.91
0.6180
1437.68
0.6538
1440.39
0.6893
1443.06
0.7246
1445.66
0.7597
1448.21
0.7946
1450.70
0.8293
1453.14
0.8638
1455.51
0.8981
1457.81
0.9323
1460.06
0.9662
1462.24
1.0000
1464.35
1.0336
1466.40
1.0670
1468.37
1.1003
1470.28
1.1334
1472.11
1.1664
1473.88
1.1992
1475.56
1.2318
1477.17
1.2643
1478.70
1.2967
1480.16
1.3289
1481.53
1.3610
1482.82
1.3929
1484.02
1.4248
1485.14
1.4565
1486.17
1.4881
1487.11
1.5196
1487.95
1.5509
1488.70
1.5822
1489.36
1.6134
1489.91
1.6446
1490.36
1.6756
1490.70
1.7065
1490.94
1.7374
1491.06
1.7683
1491.07
1.7990
1490.57
1.8758
1489.27
1.9523
1487.09
2.0288
1483.94
2.1054
1479.72
2.1823
1474.31
2.2596
1467.53
2.3377
1459.19
2.4168
1449.01
2.4973
1436.63
2.5797
1421.57
2.6647
1403.08
2.7533
1379.99
2.8474
1350.23
2.9502
1309.12
3.0702
1239.32
3.2437
1119.22
3.5542
b Punto de ebullición normal
Vapor
cp /cv
Vapor
7.1213
6.9088
6.6602
6.4396
6.2425
6.2056
6.1694
6.1339
6.1221
6.0992
6.0651
6.0317
5.9989
5.9667
5.9351
5.9041
5.8736
5.8437
5.8143
5.7853
5.7569
5.7289
5.7013
5.6741
5.6474
5.6210
5.5951
5.5695
5.5442
5.5192
5.4946
5.4703
5.4463
5.4226
5.3991
5.3759
5.3529
5.3301
5.3076
5.2853
5.2631
5.2412
5.2194
5.1978
5.1763
5.1549
5.1337
5.1126
5.0915
5.0706
5.0497
4.9977
4.9458
4.8939
4.8415
4.7885
4.7344
4.6789
4.6213
4.5612
4.4975
4.4291
4.3542
4.2702
4.1719
4.0483
3.8571
3.5542
1.325
1.327
1.330
1.335
1.342
1.343
1.345
1.347
1.348
1.349
1.351
1.353
1.355
1.358
1.360
1.363
1.365
1.368
1.371
1.375
1.378
1.382
1.385
1.389
1.393
1.398
1.402
1.407
1.412
1.417
1.422
1.428
1.434
1.440
1.446
1.453
1.460
1.468
1.475
1.484
1.492
1.501
1.510
1.520
1.530
1.541
1.553
1.565
1.577
1.591
1.605
1.643
1.687
1.739
1.799
1.870
1.955
2.058
2.187
2.349
2.562
2.851
3.26
3.91
5.04
7.62
20.66

c Punto crítico
Datos Refrigerantes
Volumen,
m3/kg
Vapor
15.602
9.0079
4.7057
2.6277
1.5533
1.4068
1.2765
1.1604
1.1242
1.0567
0.96396
0.88082
0.80614
0.73896
0.67840
0.62373
0.57428
0.52949
0.48885
0.45192
0.41830
0.38767
0.35970
0.33414
0.31074
0.28930
0.26962
0.25153
0.23489
0.21956
0.20543
0.19237
0.18031
0.16914
0.15879
0.14920
0.14029
0.13201
0.12431
0.11714
0.11046
0.10422
0.09840
0.09296
0.08787
0.08310
0.07863
0.07445
0.07052
0.06682
0.06335
0.05554
0.04880
0.04296
0.03787
0.03342
0.02951
0.02606
0.02300
0.02027
0.01782
0.01561
0.01360
0.01174
0.00999
0.00828
0.00638
0.00444
a̯Punto triple
167
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Densidad,
kg/m3
Liquido
–77.65
0.00609
732.9
–70
0.01094
724.7
–60
0.02189
713.6
–50
0.04084
702.1
–40
0.07169
690.2
–38
0.07971
687.7
–36
0.08845
685.3
–34
0.09795
682.8
–33.33b
0.10133
682.0
–32
0.10826
680.3
–30
0.11943
677.8
–28
0.13151
675.3
–26
0.14457
672.8
–24
0.15864
670.3
–22
0.17379
667.7
–20
0.19008
665.1
–18
0.20756
662.6
–16
0.22630
660.0
–14
0.24637
657.3
–12
0.26782
654.7
–10
0.29071
652.1
–8
0.31513
649.4
–6
0.34114
646.7
–4
0.36880
644.0
–2
0.39819
641.3
0
0.42938
638.6
2
0.46246
635.8
4
0.49748
633.1
6
0.53453
630.3
8
0.57370
627.5
10
0.61505
624.6
12
0.65866
621.8
14
0.70463
618.9
16
0.75303
616.0
18
0.80395
613.1
20
0.85748
610.2
22
0.91369
607.2
24
0.97268
604.3
26
1.03450
601.3
28
1.09930
598.2
30
1.16720
595.2
32
1.23820
592.1
34
1.31240
589.0
36
1.39000
585.8
38
1.47090
582.6
40
1.55540
579.4
42
1.64350
576.2
44
1.73530
572.9
46
1.83100
569.6
48
1.93050
566.3
50
2.03400
562.9
55
2.31110
554.2
60
2.61560
545.2
65
2.94910
536.0
70
3.31350
526.3
75
3.71050
516.2
80
4.14200
505.7
85
4.61000
494.5
90
5.11670
482.8
95
5.66430
470.2
100
6.25530
456.6
105
6.89230
441.9
110
7.57830
425.6
115
8.31700
407.2
120
9.11250
385.5
125
9.97002
357.8
130
10.89770
312.3
132.25c
11.33300
225.0
*Temperaturas en escala ITS-90
Temp.,*
°C
09.fm Page 168 Thursday, March 3, 2016 12:46 PM
168
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.5 (I-P) Diagrama de Presión-Entalpia para Refrigerante 404A [2013F, Ch 30, Fig. 14]
09.fm Page 169 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
169
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.5 (SI) Diagrama de Presión-Entalpia para Refrigerante 404A [2013F, Ch 30, Fig. 14]
09.fm Page 170 Thursday, March 3, 2016 12:46 PM
Burbuja
–129.56
–120.05
–112.90
–107.10
–102.18
–94.08
–87.49
–81.89
–77.00
–72.64
–65.08
–58.65
–53.01
–51.20
–47.98
–43.42
–39.24
–35.37
–31.77
–28.39
–25.21
–22.20
–19.34
–16.62
–14.01
–11.52
–9.12
–6.81
–4.59
–2.44
–0.36
1.65
6.43
10.89
15.07
19.02
22.76
26.32
29.71
32.96
36.07
39.07
44.73
50.02
54.99
59.68
64.13
68.36
72.40
76.26
79.97
83.53
90.27
96.57
102.48
108.06
113.34
118.36
123.14
127.71
132.09
136.28
146.07
154.97
162.50
*Temperaturas en escala ITS-90
Rocío
–127.50
–118.11
–111.03
–105.29
–100.42
–92.40
–85.87
–80.32
–75.46
–71.14
–63.64
–57.25
–51.65
–49.85
–46.65
–42.11
–37.96
–34.11
–30.53
–27.17
–24.01
–21.02
–18.17
–15.46
–12.87
–10.39
–8.01
–5.71
–3.50
–1.36
0.71
2.71
7.47
11.90
16.07
20.00
23.72
27.27
30.64
33.88
36.98
39.96
45.60
50.86
55.81
60.48
64.91
69.13
73.15
76.99
80.68
84.23
90.94
97.21
103.09
108.64
113.90
118.89
123.65
128.19
132.54
136.71
146.42
155.22
162.50
Densidad,
lb/ft3
Líquido
89.61
88.64
87.92
87.33
86.83
86.01
85.33
84.76
84.25
83.80
83.01
82.34
81.74
81.55
81.20
80.71
80.26
79.83
79.44
79.06
78.71
78.37
78.05
77.74
77.44
77.15
76.87
76.60
76.34
76.09
75.84
75.60
75.03
74.48
73.97
73.47
72.99
72.54
72.09
71.67
71.25
70.84
70.06
69.32
68.60
67.90
67.23
66.57
65.93
65.30
64.68
64.07
62.87
61.70
60.53
59.37
58.20
57.03
55.83
54.61
53.35
52.03
48.36
43.51
35.84
b
Entalpia, Btu/lb
Volumen, ft3/lb
Vapor
36.2311
24.7754
18.9245
15.3578
12.9493
9.8941
8.0300
6.7705
5.8607
5.1716
4.1954
3.5353
3.0582
2.9217
2.6968
2.4132
2.1845
1.9960
1.8379
1.7033
1.5873
1.4863
1.3974
1.3187
1.2484
1.1852
1.1281
1.0763
1.0290
0.9857
0.9459
0.9091
0.8285
0.7609
0.7033
0.6537
0.6104
0.5724
0.5387
0.5085
0.4815
0.4570
0.4145
0.3789
0.3485
0.3222
0.2994
0.2793
0.2614
0.2454
0.2311
0.2181
0.1955
0.1764
0.1601
0.1460
0.1336
0.1226
0.1127
0.1038
0.0956
0.0881
0.0713
0.0556
0.0279
Líquido
–26.33
–23.56
–21.49
–19.81
–18.38
–16.02
–14.10
–12.46
–11.02
–9.74
–7.51
–5.60
–3.91
–3.37
–2.41
–1.03
0.23
1.40
2.50
3.53
4.51
5.44
6.32
7.16
7.97
8.75
9.50
10.22
10.92
11.60
12.25
12.89
14.41
15.84
17.19
18.47
19.69
20.86
21.98
23.05
24.09
25.10
27.01
28.82
30.53
32.16
33.73
35.23
36.68
38.08
39.44
40.76
43.29
45.70
48.02
50.25
52.42
54.54
56.61
58.65
60.67
62.68
67.80
73.49
80.85
Vapor
71.76
73.11
74.14
74.98
75.69
76.86
77.82
78.64
79.35
79.98
81.07
82.00
82.81
83.07
83.53
84.18
84.78
85.32
85.83
86.30
86.75
87.16
87.56
87.93
88.29
88.62
88.95
89.26
89.56
89.84
90.12
90.38
91.01
91.58
92.11
92.61
93.07
93.50
93.91
94.30
94.66
95.00
95.64
96.21
96.73
97.20
97.62
98.01
98.37
98.69
98.98
99.25
99.70
100.05
100.32
100.51
100.61
100.64
100.58
100.43
100.20
99.85
98.42
95.51
80.85
Puntos de burbuja y rocío en una atmósfera estándar
Entropía, Btu/lby°F
Líquido
–0.07039
–0.06215
–0.05611
–0.05129
–0.04727
–0.04076
–0.03555
–0.03119
–0.02742
–0.02409
–0.01839
–0.01360
–0.00944
–0.00812
–0.00577
–0.00246
0.00055
0.00332
0.00588
0.00827
0.01051
0.01263
0.01463
0.01653
0.01834
0.02007
0.02172
0.02331
0.02484
0.02632
0.02774
0.02911
0.03237
0.03539
0.03822
0.04088
0.04339
0.04578
0.04804
0.05021
0.05229
0.05428
0.05804
0.06155
0.06485
0.06795
0.07090
0.07371
0.07639
0.07896
0.08143
0.08381
0.08833
0.09259
0.09663
0.10047
0.10417
0.10773
0.11118
0.11456
0.11787
0.12114
0.12934
0.13833
0.14987
c
Vapor
0.22616
0.22201
0.21920
0.21710
0.21544
0.21292
0.21106
0.20960
0.20841
0.20741
0.20581
0.20457
0.20357
0.20326
0.20273
0.20203
0.20141
0.20088
0.20041
0.19998
0.19960
0.19925
0.19894
0.19864
0.19838
0.19813
0.19790
0.19768
0.19748
0.19729
0.19711
0.19694
0.19655
0.19621
0.19590
0.19562
0.19537
0.19514
0.19492
0.19471
0.19452
0.19434
0.19400
0.19368
0.19338
0.19309
0.19281
0.19253
0.19226
0.19198
0.19170
0.19143
0.19085
0.19026
0.18962
0.18895
0.18823
0.18745
0.18660
0.18566
0.18464
0.18349
0.17987
0.17416
0.14987
Punto Crítico
170
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Temperatura,* °F
Presión, psia
1
1.5
2
2.5
3
4
5
6
7
8
10
12
14
14.7b
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
55
60
65
70
75
80
85
90
95
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
360
380
400
450
500
548.24c
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.8 (I-P) R-404A [R-125/143a/134a (44/52/4)] Propiedades del Líquido en
Línea de Burbuja y Vapor en Línea de Rocío [2013F, Ch 30, Tbl R-404A]
09.fm Page 171 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.8 (SI) R-404A [R-125/143a/134a (44/52/4)] Propiedades de Líquido en
Línea de Burbuja y Vapor en Línea de Rocío [2013F, Ch 30, Tbl R-404A]
Presión,
MPa
Temperatura,* °C
*Temperaturas en escala ITS-90
Densidad,
kg/m3
Líquido
1447.1
1440.6
1434.9
1429.9
1425.4
1421.3
1392.4
1359.4
1337.7
1321.0
1307.1
1306.3
1295.1
1284.5
1275.0
1266.2
1258.0
1250.4
1243.3
1236.5
1230.1
1223.9
1218.0
1212.4
1206.9
1201.6
1196.5
1191.6
1186.7
1182.0
1177.5
1173.0
1162.3
1152.0
1142.3
1132.9
1123.8
1115.1
1106.5
1098.2
1090.2
1082.2
1066.9
1052.0
1037.5
1023.4
1009.5
995.7
982.1
968.6
955.1
941.6
928.1
914.4
900.6
886.5
872.2
857.5
842.4
826.8
810.5
793.4
755.6
709.8
486.5
Volumen,
m3/kg
Vapor
3.05794
2.57690
2.22992
1.96748
1.76182
1.59620
0.83425
0.43619
0.29837
0.22779
0.18467
0.18240
0.15551
0.13443
0.11846
0.10592
0.09581
0.08748
0.08049
0.07454
0.06941
0.06494
0.06101
0.05752
0.05441
0.05162
0.04909
0.04680
0.04471
0.04279
0.04103
0.03940
0.03584
0.03284
0.03029
0.02809
0.02618
0.02449
0.02300
0.02166
0.02046
0.01937
0.01749
0.01590
0.01455
0.01338
0.01236
0.01146
0.01066
0.00994
0.00930
0.00871
0.00817
0.00768
0.00723
0.00680
0.00641
0.00604
0.00569
0.00536
0.00505
0.00475
0.00417
0.00361
0.00206
bPuntos
Entalpia,
kJ/kg
Líquido
81.16
83.85
86.19
88.26
90.13
91.83
103.81
117.48
126.44
133.31
138.97
139.31
143.83
148.12
151.97
155.49
158.73
161.75
164.57
167.23
169.75
172.14
174.43
176.61
178.71
180.73
182.68
184.56
186.38
188.15
189.86
191.53
195.51
199.26
202.81
206.18
209.41
212.49
215.46
218.32
221.09
223.77
228.89
233.75
238.37
242.81
247.07
251.19
255.17
259.05
262.83
266.52
270.14
273.70
277.20
280.66
284.09
287.50
290.89
294.29
297.70
301.15
308.25
315.97
343.92
Vapor
311.61
312.92
314.06
315.07
315.99
316.83
322.78
329.58
334.00
337.36
340.08
340.25
342.40
344.41
346.20
347.81
349.28
350.63
351.88
353.04
354.13
355.15
356.12
357.03
357.90
358.72
359.51
360.26
360.98
361.67
362.33
362.96
364.45
365.81
367.06
368.21
369.28
370.27
371.19
372.05
372.85
373.59
374.94
376.12
377.14
378.02
378.78
379.42
379.95
380.38
380.70
380.92
381.05
381.08
381.01
380.83
380.55
380.15
379.62
378.96
378.14
377.15
374.49
370.45
343.92
Entropía,
kJ/(kgyK)
Líquido
0.4716
0.4865
0.4993
0.5106
0.5206
0.5296
0.5917
0.6587
0.7007
0.7320
0.7571
0.7586
0.7783
0.7967
0.8130
0.8277
0.8411
0.8534
0.8649
0.8755
0.8855
0.8950
0.9039
0.9125
0.9206
0.9283
0.9358
0.9429
0.9498
0.9564
0.9628
0.9690
0.9837
0.9973
1.0101
1.0222
1.0336
1.0444
1.0547
1.0646
1.0741
1.0832
1.1005
1.1166
1.1318
1.1462
1.1599
1.1730
1.1856
1.1977
1.2095
1.2208
1.2319
1.2427
1.2532
1.2635
1.2737
1.2837
1.2937
1.3036
1.3135
1.3234
1.3438
1.3657
1.4455
Vapor
1.7532
1.7450
1.7382
1.7324
1.7273
1.7229
1.6953
1.6707
1.6578
1.6494
1.6434
1.6430
1.6387
1.6349
1.6318
1.6292
1.6270
1.6250
1.6233
1.6217
1.6203
1.6190
1.6179
1.6168
1.6158
1.6149
1.6141
1.6133
1.6125
1.6118
1.6112
1.6105
1.6091
1.6078
1.6066
1.6055
1.6044
1.6035
1.6025
1.6016
1.6007
1.5999
1.5982
1.5965
1.5949
1.5932
1.5914
1.5896
1.5878
1.5858
1.5838
1.5817
1.5794
1.5770
1.5745
1.5718
1.5689
1.5658
1.5624
1.5587
1.5547
1.5503
1.5397
1.5255
1.4455
Calor Específico cp
kJ/(kgyK)
Líquido
1.220
1.218
1.216
1.215
1.214
1.214
1.215
1.225
1.234
1.243
1.251
1.252
1.259
1.266
1.273
1.279
1.285
1.291
1.297
1.303
1.308
1.313
1.319
1.324
1.329
1.334
1.339
1.344
1.349
1.353
1.358
1.363
1.374
1.386
1.397
1.409
1.420
1.432
1.443
1.455
1.466
1.478
1.503
1.528
1.554
1.582
1.611
1.643
1.676
1.712
1.751
1.794
1.841
1.893
1.952
2.019
2.095
2.183
2.288
2.414
2.569
2.765
3.381
4.771
—
Vapor
0.640
0.646
0.651
0.655
0.660
0.663
0.691
0.725
0.749
0.767
0.784
0.785
0.798
0.811
0.823
0.834
0.844
0.855
0.864
0.873
0.882
0.891
0.899
0.907
0.915
0.923
0.931
0.938
0.946
0.953
0.960
0.967
0.984
1.001
1.018
1.034
1.051
1.067
1.084
1.100
1.117
1.134
1.169
1.206
1.244
1.285
1.329
1.376
1.426
1.481
1.541
1.607
1.681
1.763
1.856
1.962
2.085
2.229
2.401
2.609
2.868
3.197
4.233
6.536
—
cp/cv
Vapor
1.163
1.162
1.161
1.161
1.160
1.160
1.159
1.159
1.161
1.163
1.166
1.166
1.169
1.171
1.174
1.177
1.179
1.182
1.185
1.188
1.190
1.193
1.196
1.199
1.202
1.205
1.208
1.211
1.214
1.217
1.220
1.223
1.231
1.239
1.247
1.256
1.264
1.274
1.283
1.293
1.303
1.313
1.336
1.360
1.386
1.414
1.445
1.478
1.515
1.556
1.601
1.652
1.709
1.774
1.847
1.932
2.032
2.149
2.289
2.459
2.672
2.944
3.797
5.689
—
de burbuja y rocío en una atmósfera estándar
171
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
Rocío
–92.50
–90.32
–88.42
–86.74
–85.22
–83.84
–74.08
–62.97
–55.75
–50.25
–45.74
–45.47
–41.90
–38.53
–35.51
–32.78
–30.27
–27.94
–25.78
–23.75
–21.83
–20.02
–18.29
–16.65
–15.08
–13.57
–12.12
–10.73
–9.39
–8.09
–6.83
–5.61
–2.72
–0.02
2.52
4.91
7.18
9.34
11.40
13.37
15.26
17.08
20.52
23.73
26.75
29.60
32.30
34.87
37.32
39.67
41.91
44.07
46.15
48.15
50.08
51.95
53.76
55.51
57.21
58.86
60.46
62.01
64.99
67.81
72.05
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Burbuja
0.005
–93.70
0.006
–91.48
0.007
–89.56
0.008
–87.86
0.009
–86.32
0.01
–84.93
0.02
–75.05
0.04
–63.85
0.06
–56.57
0.08
–51.03
0.1
–46.50
0.10132b –46.22
0.12
–42.63
0.14
–39.24
0.16
–36.20
0.18
–33.45
0.2
–30.93
0.22
–28.59
0.24
–26.42
0.26
–24.37
0.28
–22.45
0.3
–20.62
0.32
–18.89
0.34
–17.24
0.36
–15.66
0.38
–14.15
0.4
–12.69
0.42
–11.29
0.44
–9.94
0.46
–8.64
0.48
–7.37
0.5
–6.15
0.55
–3.24
0.6
–0.53
0.65
2.02
0.7
4.42
0.75
6.70
0.8
8.87
0.85
10.94
0.9
12.92
0.95
14.81
1.0
16.64
1.1
20.09
1.2
23.32
1.3
26.35
1.4
29.22
1.5
31.93
1.6
34.51
1.7
36.97
1.8
39.33
1.9
41.58
2.0
43.75
2.1
45.84
2.2
47.85
2.3
49.80
2.4
51.68
2.5
53.50
2.6
55.26
2.7
56.97
2.8
58.63
2.9
60.24
3.0
61.81
3.2
64.82
3.4
67.67
c
3.729
72.05
09.fm Page 172 Thursday, March 3, 2016 12:46 PM
172
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.6 (I-P) Diagrama de Presión-Entalpia para Refrigerante 407C [2013F, Ch 30, Fig 15]
09.fm Page 173 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
173
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.6 (SI) Diagrama Presión-Entalpia para Refrigerante 407C [2013F, Ch 30, Fig 15]
09.fm Page 174 Thursday, March 3, 2016 12:46 PM
1
1.5
2
2.5
3
4
5
6
7
8
10
12
14
14.7b
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
55
60
65
70
75
80
85
90
95
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
360
380
400
450
500
550
600
650
673.36c
Temp.,* °F
Burbuja Rocío
–125.19 –111.30
–115.58 –101.85
–108.36 –94.75
–102.52 –88.99
–97.57
–84.12
–89.43
–76.11
–82.81
–69.61
–77.20
–64.09
–72.30
–59.27
–67.94
–54.97
–60.38
–47.55
–53.96
–41.23
–48.34
–35.71
–46.53
–33.93
–43.32
–30.78
–38.77
–26.31
–34.61
–22.23
–30.76
–18.45
–27.18
–14.93
–23.83
–11.64
–20.66
–8.54
–17.67
–5.60
–14.84
–2.82
–12.13
–0.17
–9.55
2.37
–7.07
4.79
–4.70
7.12
–2.41
9.37
–0.20
11.53
1.93
13.61
3.98
15.63
5.98
17.58
10.71
22.21
15.13
26.53
19.27
30.58
23.18
34.40
26.88
38.02
30.39
41.46
33.75
44.73
36.96
47.87
40.04
50.87
43.00
53.75
48.60
59.21
53.83
64.30
58.75
69.08
63.39
73.59
67.79
77.86
71.98
81.92
75.97
85.79
79.80
89.49
83.47
93.04
87.00
96.45
93.69
102.90
99.94
108.92
105.82
114.56
111.37
119.88
116.64
124.91
121.66
129.69
126.45
134.24
131.03
138.58
135.43
142.73
139.66
146.71
149.59
155.98
158.73
164.41
167.22
172.09
175.17
179.07
182.79
185.22
186.94
186.94
*Temperaturas en escala ITS-90
Densidad,
lb/ft3
Líquido
94.24
93.28
92.55
91.97
91.47
90.64
89.97
89.40
88.89
88.44
87.66
86.98
86.39
86.19
85.85
85.36
84.91
84.50
84.10
83.73
83.38
83.05
82.73
82.43
82.14
81.85
81.58
81.32
81.06
80.82
80.58
80.34
79.78
79.25
78.75
78.27
77.82
77.38
76.95
76.54
76.15
75.76
75.02
74.32
73.64
72.99
72.37
71.76
71.17
70.59
70.02
69.47
68.40
67.35
66.33
65.33
64.34
63.37
62.39
61.42
60.44
59.46
56.92
54.21
51.15
47.39
41.60
31.59
Volumen,
ft3/lb
Vapor
43.0887
29.4430
22.4776
18.2333
15.3685
11.7361
9.5211
8.0252
6.9450
6.1272
4.9690
4.1864
3.6210
3.4593
3.1928
2.8570
2.5862
2.3632
2.1761
2.0169
1.8798
1.7603
1.6553
1.5622
1.4791
1.4045
1.3371
1.2759
1.2201
1.1690
1.1220
1.0786
0.9835
0.9037
0.8359
0.7774
0.7264
0.6816
0.6419
0.6064
0.5746
0.5458
0.4959
0.4540
0.4183
0.3875
0.3607
0.3372
0.3163
0.2976
0.2808
0.2656
0.2393
0.2171
0.1982
0.1819
0.1676
0.1550
0.1438
0.1337
0.1246
0.1163
0.0984
0.0835
0.0706
0.0586
0.0457
0.0317
b
Entalpia,
Btu/lb
Líquido
Vapor
–26.34
93.96
–23.40
95.34
–21.18
96.37
–19.39
97.21
–17.87
97.92
–15.37
99.09
–13.34
100.03
–11.60
100.83
–10.09
101.52
–8.74
102.13
–6.39
103.19
–4.38
104.08
–2.62
104.85
–2.06
105.10
–1.05
105.54
0.39
106.15
1.70
106.71
2.92
107.22
4.06
107.70
5.13
108.14
6.15
108.55
7.10
108.93
8.02
109.30
8.89
109.64
9.72
109.97
10.53
110.28
11.30
110.58
12.04
110.86
12.76
111.13
13.46
111.39
14.13
111.64
14.79
111.88
16.34
112.44
17.81
112.96
19.19
113.44
20.49
113.88
21.74
114.29
22.92
114.67
24.06
115.03
25.16
115.37
26.21
115.68
27.23
115.98
29.16
116.53
30.99
117.03
32.72
117.47
34.36
117.88
35.94
118.24
37.45
118.57
38.90
118.87
40.30
119.15
41.66
119.39
42.97
119.61
45.49
119.99
47.88
120.29
50.17
120.52
52.36
120.68
54.48
120.78
56.53
120.82
58.53
120.80
60.47
120.73
62.38
120.61
64.25
120.42
68.84
119.71
73.37
118.56
78.00
116.83
83.04
114.18
89.56
109.19
99.99
99.99
Entropía,
Btu/lby°F
Líquido
Vapor
–0.07002
0.28254
–0.06135
0.27716
–0.05499
0.27346
–0.04994
0.27066
–0.04572
0.26841
–0.03889
0.26495
–0.03345
0.26234
–0.02889
0.26025
–0.02496
0.25852
–0.02149
0.25705
–0.01556
0.25464
–0.01059
0.25272
–0.00629
0.25114
–0.00492
0.25065
–0.00249
0.24979
0.00092
0.24863
0.00402
0.24760
0.00687
0.24668
0.00950
0.24586
0.01196
0.24510
0.01426
0.24442
0.01643
0.24378
0.01848
0.24319
0.02042
0.24265
0.02227
0.24213
0.02404
0.24165
0.02573
0.24120
0.02735
0.24077
0.02891
0.24036
0.03041
0.23998
0.03186
0.23961
0.03326
0.23926
0.03656
0.23844
0.03963
0.23771
0.04250
0.23703
0.04519
0.23641
0.04773
0.23584
0.05014
0.23530
0.05243
0.23480
0.05462
0.23432
0.05671
0.23387
0.05871
0.23344
0.06250
0.23265
0.06602
0.23191
0.06932
0.23122
0.07244
0.23058
0.07538
0.22997
0.07818
0.22938
0.08086
0.22882
0.08341
0.22828
0.08587
0.22776
0.08823
0.22725
0.09271
0.22625
0.09691
0.22529
0.10088
0.22434
0.10464
0.22340
0.10824
0.22246
0.11168
0.22152
0.11500
0.22056
0.11821
0.21958
0.12132
0.21857
0.12435
0.21753
0.13167
0.21473
0.13879
0.21152
0.14595
0.20765
0.15363
0.20253
0.16351
0.19401
0.17797
0.17797
Puntos de burbuja y rocío en una atmósfera estándar
Calor Específico cp,
Btu/lby°F
Líquido
Vapor
0.3065
0.1568
0.3063
0.1600
0.3063
0.1624
0.3065
0.1644
0.3068
0.1662
0.3074
0.1693
0.3081
0.1719
0.3087
0.1742
0.3094
0.1762
0.3100
0.1781
0.3112
0.1814
0.3123
0.1844
0.3133
0.1871
0.3137
0.1880
0.3143
0.1896
0.3153
0.1919
0.3162
0.1941
0.3172
0.1961
0.3180
0.1981
0.3189
0.1999
0.3197
0.2017
0.3205
0.2034
0.3213
0.2051
0.3221
0.2067
0.3229
0.2083
0.3236
0.2098
0.3244
0.2113
0.3251
0.2127
0.3258
0.2141
0.3265
0.2155
0.3272
0.2169
0.3279
0.2182
0.3296
0.2214
0.3313
0.2246
0.3329
0.2276
0.3346
0.2305
0.3362
0.2333
0.3378
0.2361
0.3393
0.2389
0.3409
0.2416
0.3424
0.2442
0.3440
0.2468
0.3471
0.2520
0.3502
0.2570
0.3533
0.2621
0.3564
0.2671
0.3596
0.2721
0.3628
0.2772
0.3660
0.2824
0.3693
0.2876
0.3727
0.2929
0.3761
0.2983
0.3832
0.3095
0.3907
0.3213
0.3986
0.3338
0.4070
0.3473
0.4161
0.3618
0.4260
0.3777
0.4368
0.3951
0.4487
0.4143
0.4620
0.4358
0.4769
0.4600
0.5248
0.5373
0.5982
0.6546
0.7284
0.8572
1.0271
1.2973
2.4146
3.0022
—
—
c
cp/cv
Vapor
1.183
1.182
1.181
1.181
1.181
1.181
1.182
1.182
1.183
1.184
1.186
1.188
1.189
1.190
1.191
1.193
1.195
1.197
1.199
1.201
1.203
1.205
1.207
1.209
1.211
1.213
1.215
1.217
1.219
1.221
1.223
1.225
1.230
1.235
1.240
1.245
1.250
1.255
1.260
1.266
1.271
1.276
1.287
1.298
1.310
1.321
1.334
1.346
1.359
1.373
1.387
1.401
1.432
1.466
1.502
1.542
1.586
1.635
1.689
1.750
1.819
1.897
2.151
2.541
3.217
4.683
10.265
—
Punto critic
174
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Presión ,
psia
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.9 (I-P) R-407C[R-32/125/134a (23/25/52)] Propiedades de Líquido en
Línea de Burbuja y Vapor en Línea de Rocío [2013F, Ch 30, Tbl R-407C]
09.fm Page 175 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.9 (SI) R-407C[R-32/125/134a (23/25/52)] Propiedades de Líquido en
Línea de Burbuja y Vapor en Línea de Rocío [2013F, Ch 30, Tbl R-407C]
Presión ,
MPa
*Temperaturas en escala ITS-90
Densidad, Volumen,
kg/m3
m3/kg
Líquido
Vapor
1495.5
1466.7
1433.7
1412.0
1395.3
1381.5
1380.7
1369.7
1359.1
1349.7
1341.0
1333.0
1325.5
1318.4
1311.8
1305.5
1299.5
1293.7
1288.2
1282.9
1277.8
1272.8
1268.0
1263.4
1258.8
1254.4
1250.1
1239.8
1230.0
1220.7
1211.7
1203.1
1194.9
1186.8
1179.1
1171.5
1164.1
1149.9
1136.2
1123.0
1110.2
1097.7
1085.5
1073.5
1061.7
1050.0
1038.5
1027.1
1015.7
1004.4
993.1
981.8
970.5
959.0
947.5
935.9
924.1
899.9
874.6
847.6
818.1
785.1
746.0
484.2
1.89703
0.99017
0.51705
0.35346
0.26975
0.21865
0.21595
0.18411
0.15916
0.14025
0.12542
0.11347
0.10362
0.09536
0.08833
0.08227
0.07699
0.07235
0.06824
0.06457
0.06127
0.05830
0.05559
0.05313
0.05087
0.04879
0.04687
0.04267
0.03915
0.03615
0.03356
0.03131
0.02933
0.02757
0.02600
0.02460
0.02332
0.02111
0.01926
0.01768
0.01631
0.01512
0.01408
0.01315
0.01231
0.01157
0.01089
0.01027
0.00971
0.00919
0.00871
0.00827
0.00786
0.00747
0.00711
0.00677
0.00645
0.00587
0.00533
0.00484
0.00439
0.00395
0.00352
0.00207
b Puntos
Entropía,
kJ/(kgyK)
Líquido
Vapor
0.5259
1.9471
0.5910
1.9104
0.6612
1.8761
0.7050
1.8573
0.7374
1.8445
0.7635
1.8349
0.7650
1.8343
0.7854
1.8273
0.8043
1.8210
0.8211
1.8156
0.8362
1.8110
0.8499
1.8069
0.8625
1.8033
0.8742
1.8000
0.8851
1.7970
0.8954
1.7942
0.9050
1.7917
0.9141
1.7894
0.9228
1.7872
0.9310
1.7851
0.9389
1.7832
0.9465
1.7814
0.9537
1.7796
0.9607
1.7780
0.9674
1.7764
0.9739
1.7750
0.9801
1.7735
0.9950
1.7702
1.0087
1.7672
1.0216
1.7644
1.0338
1.7618
1.0452
1.7594
1.0561
1.7571
1.0665
1.7550
1.0764
1.7529
1.0859
1.7509
1.0950
1.7491
1.1122
1.7455
1.1283
1.7421
1.1434
1.7389
1.1577
1.7358
1.1713
1.7328
1.1843
1.7298
1.1967
1.7269
1.2086
1.7241
1.2200
1.7212
1.2311
1.7184
1.2418
1.7155
1.2522
1.7126
1.2624
1.7097
1.2723
1.7068
1.2819
1.7038
1.2914
1.7007
1.3006
1.6976
1.3097
1.6944
1.3187
1.6911
1.3276
1.6877
1.3450
1.6805
1.3622
1.6726
1.3795
1.6639
1.3970
1.6540
1.4152
1.6424
1.4348
1.6281
1.5384
1.5384
Calor Específico cp
kJ/(kgyK)
Líquido
Vapor
1.281
0.668
1.283
0.694
1.291
0.727
1.299
0.750
1.306
0.769
1.312
0.786
1.312
0.787
1.318
0.800
1.324
0.813
1.329
0.825
1.334
0.837
1.339
0.848
1.344
0.858
1.349
0.868
1.354
0.877
1.358
0.886
1.362
0.895
1.367
0.903
1.371
0.911
1.375
0.919
1.379
0.927
1.383
0.934
1.387
0.942
1.391
0.949
1.395
0.956
1.399
0.963
1.403
0.970
1.413
0.987
1.422
1.004
1.432
1.020
1.441
1.036
1.451
1.052
1.460
1.067
1.469
1.082
1.479
1.098
1.488
1.113
1.498
1.128
1.517
1.159
1.537
1.190
1.557
1.222
1.578
1.255
1.600
1.289
1.622
1.324
1.645
1.361
1.669
1.400
1.695
1.440
1.722
1.483
1.750
1.529
1.780
1.577
1.813
1.629
1.847
1.684
1.884
1.744
1.924
1.810
1.968
1.881
2.016
1.958
2.069
2.044
2.128
2.139
2.268
2.365
2.451
2.657
2.701
3.050
3.065
3.613
3.647
4.486
4.726
6.029
—
—
de burbuja y rocío en una atmósfera estándar
c
Entalpia,
kJ/kg
Líquido
Vapor
90.48
366.78
103.24
372.75
117.72
379.47
127.17
383.77
134.39
386.99
140.31
389.59
140.67
389.75
145.39
391.78
149.86
393.68
153.86
395.36
157.51
396.86
160.87
398.22
163.99
399.47
166.91
400.62
169.65
401.69
172.24
402.69
174.71
403.62
177.06
404.49
179.30
405.32
181.45
406.10
183.52
406.85
185.52
407.55
187.44
408.23
189.30
408.87
191.11
409.48
192.86
410.07
194.56
410.64
198.61
411.95
202.42
413.15
206.02
414.25
209.44
415.25
212.71
416.18
215.83
417.03
218.83
417.83
221.71
418.57
224.50
419.25
227.19
419.89
232.34
421.03
237.20
422.03
241.82
422.89
246.24
423.63
250.48
424.27
254.57
424.80
258.51
425.25
262.33
425.61
266.05
425.89
269.66
426.10
273.19
426.23
276.64
426.29
280.02
426.28
283.34
426.20
286.60
426.06
289.82
425.85
292.99
425.57
296.12
425.21
299.23
424.79
302.31
424.29
308.43
423.06
314.54
421.46
320.71
419.45
327.02
416.91
333.64
413.66
340.83
409.34
378.48
378.48
cp/cv
Vapor
1.182
1.181
1.182
1.184
1.187
1.190
1.190
1.193
1.196
1.199
1.201
1.204
1.207
1.210
1.213
1.216
1.219
1.222
1.224
1.227
1.230
1.233
1.236
1.239
1.242
1.245
1.248
1.255
1.262
1.270
1.278
1.286
1.294
1.302
1.310
1.319
1.327
1.346
1.365
1.385
1.406
1.428
1.452
1.477
1.504
1.533
1.564
1.597
1.633
1.671
1.713
1.758
1.808
1.863
1.923
1.990
2.065
2.243
2.475
2.789
3.239
3.935
5.159
—
Punto critic
175
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
Rocío
–74.81
–65.02
–53.95
–46.79
–41.34
–36.90
–36.63
–33.11
–29.79
–26.83
–24.15
–21.69
–19.41
–17.29
–15.31
–13.43
–11.66
–9.98
–8.38
–6.85
–5.38
–3.97
–2.61
–1.31
–0.04
1.18
2.36
5.17
7.79
10.24
12.56
14.76
16.85
18.84
20.74
22.56
24.32
27.63
30.73
33.63
36.37
38.97
41.43
43.78
46.03
48.18
50.25
52.24
54.15
56.00
57.79
59.51
61.19
62.81
64.38
65.91
67.40
70.25
72.94
75.50
77.92
80.21
82.37
86.03
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
0.01
0.02
0.04
0.06
0.08
0.1
0.10132b
0.12
0.14
0.16
0.18
0.2
0.22
0.24
0.26
0.28
0.3
0.32
0.34
0.36
0.38
0.4
0.42
0.44
0.46
0.48
0.5
0.55
0.6
0.65
0.7
0.75
0.8
0.85
0.9
0.95
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.63c
Temperatura,* °C
Burbuja
–82.45
–72.50
–61.25
–53.96
–48.42
–43.90
–43.63
–40.05
–36.67
–33.65
–30.92
–28.41
–26.09
–23.93
–21.90
–19.99
–18.19
–16.47
–14.83
–13.27
–11.77
–10.33
–8.94
–7.61
–6.31
–5.06
–3.85
–0.98
1.70
4.22
6.60
8.85
11.00
13.04
15.00
16.88
18.69
22.11
25.30
28.30
31.14
33.83
36.39
38.84
41.18
43.43
45.59
47.67
49.68
51.63
53.51
55.34
57.11
58.83
60.51
62.14
63.73
66.80
69.73
72.53
75.22
77.82
80.32
86.03
09.fm Page 176 Thursday, March 3, 2016 12:46 PM
176
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.7 (I-P) Diagrama Presión-Entalpia para Refrigerante 410A [2013F. Ch 30, Fig 16]
09.fm Page 177 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
Diagrama Presión-Entalpia para Refrigerante 410A [2013F. Ch 30, Fig 16]
177
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.7 (SI)
09.fm Page 178 Thursday, March 3, 2016 12:46 PM
1
1.5
2
2.5
3
4
5
6
7
8
10
12
14
14.70b
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
55
60
65
70
75
80
85
90
95
100
110
120
130
140
150
160
170
180
190
200
220
240
260
280
300
320
340
360
380
400
450
500
550
600
692.78c
Temp.,* °F
Burbuja
–135.16
–126.03
–119.18
–113.63
–108.94
–101.22
–94.94
–89.63
–84.98
–80.85
–73.70
–67.62
–62.31
–60.60
–57.56
–53.27
–49.34
–45.70
–42.32
–39.15
–36.17
–33.35
–30.68
–28.13
–25.69
–23.36
–21.12
–18.96
–16.89
–14.88
–12.94
–11.07
–6.62
–2.46
1.43
5.10
8.58
11.88
15.03
18.05
20.93
23.71
28.96
33.86
38.46
42.80
46.91
50.82
54.56
58.13
61.55
64.84
71.07
76.89
82.35
87.51
92.40
97.04
101.48
105.71
109.78
113.68
122.82
131.19
138.93
146.12
158.40
Rocío
–134.98
–125.87
–119.02
–113.48
–108.78
–101.07
–94.80
–89.48
–84.84
–80.71
–73.56
–67.48
–62.16
–60.46
–57.42
–53.13
–49.19
–45.56
–42.18
–39.01
–36.02
–33.20
–30.53
–27.98
–25.54
–23.20
–20.96
–18.81
–16.73
–14.73
–12.79
–10.91
–6.45
–2.30
1.60
5.27
8.75
12.06
15.21
18.22
21.11
23.89
29.14
34.05
38.65
42.99
47.11
51.02
54.76
58.33
61.76
65.05
71.28
77.10
82.57
87.73
92.61
97.26
101.69
105.93
109.99
113.89
123.01
131.38
139.09
146.25
158.40
*Temperaturas en escala ITS-90
Densidad, Volumen,
lb/ft3
ft3/lb
Líquido
Vapor
92.02
91.10
90.41
89.84
89.36
88.57
87.92
87.36
86.87
86.44
85.67
85.02
84.44
84.26
83.93
83.45
83.02
82.61
82.23
81.87
81.54
81.21
80.90
80.61
80.33
80.05
79.79
79.54
79.29
79.05
78.82
78.59
78.05
77.54
77.06
76.60
76.15
75.73
75.32
74.93
74.54
74.17
73.46
72.78
72.13
71.51
70.90
70.32
69.75
69.20
68.66
68.13
67.10
66.11
65.14
64.19
63.26
62.34
61.42
60.52
59.61
58.70
56.39
53.97
51.32
48.24
34.18
47.6458
32.5774
24.8810
20.1891
17.0211
13.0027
10.5514
8.8953
7.6992
6.7935
5.5105
4.6434
4.0168
3.8375
3.5423
3.1699
2.8698
2.6225
2.4151
2.2386
2.0865
1.9540
1.8375
1.7343
1.6422
1.5594
1.4847
1.4168
1.3549
1.2982
1.2460
1.1979
1.0925
1.0040
0.9287
0.8638
0.8073
0.7576
0.7135
0.6742
0.6389
0.6070
0.5515
0.5051
0.4655
0.4314
0.4016
0.3755
0.3523
0.3316
0.3130
0.2962
0.2669
0.2424
0.2215
0.2034
0.1876
0.1736
0.1613
0.1501
0.1401
0.1310
0.1114
0.0952
0.0814
0.0690
0.0293
b
Entalpia,
Btu/lb
Líquido Vapor
–30.90
100.62
–27.97
101.90
–25.76
102.86
–23.98
103.63
–22.47
104.27
–19.98
105.33
–17.96
106.18
–16.24
106.89
–14.74
107.50
–13.40
108.05
–11.08
108.97
–9.10
109.75
–7.36
110.42
–6.80
110.63
–5.80
111.01
–4.39
111.54
–3.09
112.01
–1.89
112.45
–0.77
112.85
0.28
113.22
1.27
113.56
2.22
113.88
3.11
114.19
3.97
114.47
4.79
114.74
5.57
115.00
6.33
115.24
7.06
115.47
7.76
115.69
8.45
115.90
9.11
116.10
9.75
116.30
11.27
116.75
12.70
117.16
14.05
117.53
15.33
117.88
16.54
118.20
17.70
118.49
18.81
118.77
19.88
119.02
20.91
119.26
21.90
119.48
23.79
119.89
25.57
120.24
27.25
120.56
28.85
120.83
30.38
121.08
31.85
121.29
33.27
121.48
34.63
121.65
35.95
121.79
37.22
121.91
39.67
122.09
41.99
122.20
44.21
122.25
46.34
122.24
48.40
122.18
50.38
122.07
52.31
121.91
54.19
121.70
56.03
121.44
57.83
121.13
62.23
120.14
66.54
118.80
70.89
117.02
75.47
114.59
90.97
90.97
Entropía,
Btu/lby°F
Líquido
Vapor
–0.08330
0.32188
–0.07439
0.31477
–0.06786
0.30981
–0.06267
0.30602
–0.05834
0.30296
–0.05133
0.29820
–0.04574
0.29455
–0.04107
0.29162
–0.03704
0.28916
–0.03349
0.28705
–0.02743
0.28356
–0.02235
0.28075
–0.01795
0.27840
–0.01655
0.27766
–0.01407
0.27638
–0.01059
0.27461
–0.00743
0.27305
–0.00452
0.27164
–0.00184
0.27036
0.00067
0.26919
0.00301
0.26811
0.00522
0.26711
0.00730
0.26617
0.00928
0.26530
0.01116
0.26448
0.01296
0.26371
0.01467
0.26297
0.01632
0.26228
0.01791
0.26162
0.01943
0.26098
0.02090
0.26038
0.02232
0.25980
0.02568
0.25845
0.02880
0.25722
0.03171
0.25610
0.03444
0.25505
0.03702
0.25408
0.03946
0.25316
0.04178
0.25231
0.04400
0.25149
0.04611
0.25072
0.04815
0.24999
0.05198
0.24862
0.05555
0.24736
0.05890
0.24618
0.06205
0.24508
0.06503
0.24403
0.06787
0.24304
0.07057
0.24210
0.07316
0.24119
0.07565
0.24031
0.07804
0.23946
0.08258
0.23783
0.08683
0.23628
0.09084
0.23478
0.09464
0.23333
0.09827
0.23190
0.10175
0.23049
0.10509
0.22909
0.10832
0.22769
0.11145
0.22629
0.11450
0.22488
0.12182
0.22124
0.12888
0.21732
0.13590
0.21295
0.14320
0.20777
0.16781
0.16781
Puntos de burbuja y rocío en una atmósfera estándar
Calor Específico cp,
Btu/lby°F
Líquido
Vapor
0.3215
0.1568
0.3212
0.1600
0.3213
0.1626
0.3214
0.1648
0.3216
0.1668
0.3221
0.1703
0.3226
0.1733
0.3231
0.1760
0.3236
0.1785
0.3241
0.1807
0.3251
0.1848
0.3261
0.1884
0.3270
0.1917
0.3274
0.1928
0.3279
0.1947
0.3288
0.1975
0.3297
0.2002
0.3305
0.2027
0.3313
0.2050
0.3321
0.2073
0.3329
0.2094
0.3337
0.2115
0.3345
0.2135
0.3352
0.2154
0.3360
0.2173
0.3367
0.2191
0.3374
0.2208
0.3382
0.2226
0.3389
0.2242
0.3396
0.2259
0.3403
0.2275
0.3410
0.2290
0.3427
0.2328
0.3445
0.2365
0.3462
0.2400
0.3478
0.2434
0.3495
0.2467
0.3512
0.2499
0.3528
0.2531
0.3545
0.2562
0.3561
0.2592
0.3578
0.2622
0.3611
0.2681
0.3644
0.2738
0.3678
0.2795
0.3712
0.2852
0.3746
0.2908
0.3781
0.2965
0.3816
0.3022
0.3851
0.3080
0.3888
0.3139
0.3925
0.3200
0.4001
0.3325
0.4081
0.3457
0.4165
0.3599
0.4255
0.3751
0.4350
0.3915
0.4452
0.4094
0.4564
0.4290
0.4685
0.4507
0.4820
0.4747
0.4971
0.5016
0.5443
0.5857
0.6143
0.7083
0.7303
0.9059
0.9603
1.2829
—
—
c
cp/cv
Vapor
1.228
1.227
1.227
1.228
1.228
1.229
1.230
1.232
1.233
1.234
1.237
1.240
1.243
1.244
1.245
1.248
1.251
1.254
1.256
1.259
1.261
1.264
1.267
1.269
1.272
1.274
1.277
1.279
1.282
1.284
1.287
1.289
1.295
1.301
1.308
1.314
1.320
1.326
1.333
1.339
1.345
1.352
1.365
1.378
1.392
1.406
1.420
1.435
1.451
1.467
1.483
1.500
1.537
1.576
1.619
1.665
1.716
1.772
1.833
1.901
1.977
2.063
2.333
2.728
3.367
4.579
—
Punto critic
178
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Presión ,
psia
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.10 (I-P) R-410A [R-32/125 (50/50)] Propiedades de Líquido en Línea de
Burbuja y Vapor en Línea de Rocío [2013F Ch 30, Tbl R-410A]
09.fm Page 179 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.10 (SI) R-410A [R-32/125 (50/50)] Propiedades de Líquido en Línea de
Burbuja y Vapor en Línea de Rocío [2013F, Ch 30, Tbl R-410A]
Presión,
MPa
Temperatura,* °C
*Temperaturas en escala ITS-90
Densidad,
kg/m3
Líquido
Volumen,
m3/kg
Vapor
1460.6
1432.9
1401.1
1380.0
1363.9
1350.5
1349.7
1339.0
1328.8
1319.6
1311.2
1303.4
1296.2
1289.4
1283.0
1276.9
1271.1
1265.5
1260.2
1255.0
1250.1
1245.3
1240.6
1236.1
1231.8
1227.5
1223.3
1213.4
1203.9
1194.9
1186.3
1178.1
1170.1
1162.4
1154.9
1147.6
1140.5
1126.8
1113.7
1101.0
1088.8
1076.9
1065.2
1053.8
1042.6
1031.6
1020.7
1009.9
999.2
988.6
978.0
967.5
957.0
946.4
935.8
925.2
914.5
892.6
870.0
846.3
821.0
793.5
762.6
459.5
2.09888
1.09659
0.57309
0.39193
0.29918
0.24256
0.23957
0.20427
0.17661
0.15565
0.13921
0.12595
0.11503
0.10587
0.09807
0.09135
0.08550
0.08035
0.07579
0.07172
0.06806
0.06476
0.06176
0.05902
0.05652
0.05421
0.05209
0.04743
0.04352
0.04019
0.03732
0.03482
0.03262
0.03068
0.02894
0.02738
0.02596
0.02351
0.02145
0.01970
0.01819
0.01687
0.01571
0.01468
0.01376
0.01293
0.01218
0.0115
0.01088
0.01031
0.00978
0.00929
0.00883
0.00841
0.00802
0.00764
0.00729
0.00665
0.00607
0.00555
0.00506
0.00460
0.00417
0.00218
b
Entalpia, kJ/kg
Liquido
76.56
89.26
103.64
113.00
120.14
125.99
126.34
130.99
135.39
139.34
142.93
146.23
149.29
152.15
154.84
157.38
159.80
162.10
164.29
166.40
168.43
170.38
172.26
174.08
175.84
177.55
179.21
183.17
186.89
190.40
193.74
196.92
199.96
202.88
205.69
208.40
211.02
216.03
220.76
225.26
229.56
233.68
237.65
241.48
245.19
248.79
252.29
255.71
259.05
262.32
265.52
268.67
271.77
274.82
277.84
280.82
283.78
289.62
295.43
301.26
307.16
313.24
319.65
368.55
Vapor
378.76
384.25
390.29
394.10
396.92
399.17
399.31
401.05
402.67
404.09
405.36
406.50
407.53
408.49
409.36
410.18
410.94
411.65
412.32
412.95
413.54
414.10
414.64
415.14
415.63
416.09
416.53
417.54
418.46
419.28
420.03
420.71
421.33
421.89
422.41
422.88
423.31
424.07
424.68
425.19
425.59
425.89
426.11
426.25
426.31
426.31
426.24
426.10
425.90
425.64
425.33
424.95
424.51
424.02
423.47
422.85
422.18
420.62
418.78
416.60
414.03
410.97
407.24
368.55
Entropia,
kJ/(kg·K)
Líquido
Vapor
0.4588
2.0927
0.5258
2.0432
0.5978
1.9956
0.6426
1.9687
0.6758
1.9500
0.7024
1.9358
0.7040
1.9350
0.7247
1.9243
0.7441
1.9147
0.7612
1.9065
0.7766
1.8993
0.7905
1.8928
0.8034
1.8871
0.8153
1.8818
0.8264
1.8770
0.8368
1.8726
0.8466
1.8685
0.8558
1.8647
0.8646
1.8611
0.8703
1.8577
0.8810
1.8545
0.8887
1.8514
0.8960
1.8486
0.9031
1.8458
0.9099
1.8432
0.9165
1.8407
0.9228
1.8383
0.9379
1.8326
0.9518
1.8275
0.9649
1.8227
0.9772
1.8183
0.9888
1.8141
0.9998
1.8102
1.0103
1.8065
1.0204
1.8030
1.0300
1.7996
1.0392
1.7964
1.0567
1.7903
1.0730
1.7846
1.0883
1.7792
1.1027
1.7741
1.1165
1.7691
1.1296
1.7644
1.1421
1.7597
1.1542
1.7552
1.1657
1.7508
1.1769
1.7464
1.1878
1.7421
1.1983
1.7379
1.2085
1.7336
1.2185
1.7294
1.2282
1.7251
1.2377
1.7209
1.2470
1.7166
1.2561
1.7123
1.2651
1.7079
1.2740
1.7035
1.2913
1.6944
1.3085
1.6849
1.3254
1.6747
1.3425
1.6638
1.3600
1.6517
1.3783
1.6380
1.5181
1.5181
Puntos de burbuja y rocío en una atmósfera estándar
Calor Específico cp,
cp/cv
kJ/(kgyK)
Vapor
Líquido
Vapor
1.344
0.668
1.227
1.345
0.696
1.228
1.351
0.734
1.231
1.358
0.762
1.235
1.364
0.785
1.239
1.369
0.805
1.243
1.370
0.807
1.244
1.375
0.823
1.247
1.380
0.839
1.251
1.385
0.854
1.255
1.390
0.868
1.259
1.395
0.881
1.263
1.399
0.893
1.266
1.404
0.904
1.270
1.408
0.916
1.274
1.413
0.926
1.277
1.417
0.936
1.281
1.421
0.946
1.285
1.426
0.956
1.288
1.430
0.965
1.292
1.434
0.975
1.295
1.438
0.983
1.299
1.443
0.992
1.303
1.447
1.001
1.306
1.451
1.009
1.310
1.455
1.017
1.313
1.459
1.025
1.317
1.469
1.045
1.326
1.479
1.064
1.335
1.489
1.083
1.344
1.499
1.101
1.354
1.509
1.119
1.363
1.519
1.136
1.373
1.529
1.154
1.382
1.540
1.171
1.392
1.550
1.188
1.402
1.560
1.205
1.413
1.581
1.239
1.434
1.603
1.274
1.457
1.624
1.31
1.481
1.647
1.347
1.506
1.670
1.385
1.532
1.694
1.424
1.560
1.719
1.465
1.590
1.745
1.509
1.621
1.772
1.555
1.655
1.800
1.603
1.690
1.830
1.655
1.728
1.861
1.709
1.769
1.894
1.768
1.813
1.929
1.831
1.860
1.967
1.898
1.911
2.008
1.971
1.966
2.052
2.050
2.026
2.100
2.136
2.091
2.153
2.230
2.163
2.211
2.333
2.243
2.348
2.575
2.429
2.522
2.879
2.663
2.752
3.276
2.970
3.070
3.815
3.386
3.541
4.596
3.987
4.306
5.826
4.929
—
—
—
c
Punto crítico
179
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
Rocío
–88.14
–78.70
–68.04
–61.14
–55.90
–51.62
–51.36
–47.98
–44.79
–41.94
–39.36
–36.99
–34.80
–32.76
–30.85
–29.05
–27.35
–25.73
–24.19
–22.72
–21.31
–19.95
–18.65
–17.39
–16.18
–15.00
–13.86
–11.16
–8.64
–6.28
–4.05
–1.93
0.08
1.99
3.83
5.58
7.27
10.47
13.46
16.26
18.91
21.41
23.80
26.07
28.25
30.34
32.34
34.28
36.14
37.94
39.68
41.37
43.00
44.59
46.14
47.64
49.10
51.91
54.59
57.15
59.59
61.93
64.17
71.36
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Burbuja
0.01
–88.23
0.02
–78.79
0.04
–68.12
0.06
–61.22
0.08
–55.98
0.1
–51.70
0.10132b –51.44
0.12
–48.06
0.14
–44.87
0.16
–42.02
0.18
–39.44
0.2
–37.07
0.22
–34.89
0.24
–32.85
0.26
–30.94
0.28
–29.14
0.3
–27.44
0.32
–25.82
0.34
–24.28
0.36
–22.81
0.38
–21.40
0.4
–20.04
0.42
–18.74
0.44
–17.48
0.46
–16.27
0.48
–15.10
0.5
–13.96
0.55
–11.26
0.6
–8.74
0.65
–6.38
0.7
–4.15
0.75
–2.04
0.8
–0.03
0.85
1.89
0.9
3.72
0.95
5.48
1.0
7.17
1.1
10.36
1.2
13.34
1.3
16.15
1.4
18.79
1.5
21.30
1.6
23.68
1.7
25.96
1.8
28.13
1.9
30.22
2.0
32.22
2.1
34.16
2.2
36.02
2.3
37.82
2.4
39.56
2.5
41.25
2.6
42.89
2.7
44.48
2.8
46.02
2.9
47.53
3.0
48.99
3.2
51.81
3.4
54.49
3.6
57.05
3.8
59.50
4.0
61.85
4.2
64.10
4.903c
71.36
09.fm Page 180 Thursday, March 3, 2016 12:46 PM
180
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.8 (I-P) Diagrama Presión-Entalpia para Refrigerante 507A [2013F, Ch 30, Fig 17]
09.fm Page 181 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
181
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.8 (SI) Diagrama Presión-Entalpia para Refrigerante 507A [2013F, Ch 30, Fig 17]
09.fm Page 182 Thursday, March 3, 2016 12:46 PM
–150
–145
–140
–135
–130
–125
–120
–115
–110
–105
–100
–95
–90
–85
–80
–75
–70
–65
–60
–55
–52.13b
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
159.12c
Presión,**
psia
0.386
0.497
0.801
1.004
1.249
1.541
1.887
2.295
2.773
3.329
3.974
4.715
5.566
6.535
7.636
8.879
10.280
11.849
13.603
14.696
15.554
17.719
20.112
22.750
25.649
28.827
32.300
36.086
40.203
44.671
49.508
54.733
60.367
66.429
72.941
79.923
87.396
95.384
103.91
112.99
122.65
132.92
143.82
155.38
167.62
180.56
194.24
208.68
223.92
239.97
256.88
274.68
293.40
313.08
333.77
355.50
378.33
402.31
427.52
454.04
481.99
511.55
537.40
Densidad, Volumen,
lb/ft3
ft3/lb
Líquido
Vapor
92.41
91.88
91.36
90.84
90.32
89.80
89.29
88.77
88.26
87.75
87.23
86.72
86.20
85.68
85.16
84.64
84.11
83.58
83.05
82.51
82.20
81.97
81.43
80.88
80.33
79.77
79.20
78.63
78.05
77.46
76.87
76.27
75.66
75.04
74.41
73.77
73.12
72.45
71.78
71.09
70.38
69.66
68.92
68.16
67.39
66.58
65.76
64.90
64.02
63.10
62.14
61.14
60.09
58.99
57.82
56.57
55.22
53.76
52.15
50.32
48.19
45.55
41.76
30.64
86.952
68.522
54.501
43.729
35.377
28.844
23.692
19.596
16.315
13.669
11.521
9.7644
8.3201
7.1254
6.1316
5.3004
4.6018
4.0116
3.5108
3.0839
2.8676
2.7184
2.4043
2.1331
1.8983
1.6941
1.5160
1.3601
1.2231
1.1025
0.9960
0.9016
0.8177
0.7430
0.6763
0.6165
0.5629
0.5146
0.4711
0.4318
0.3962
0.3638
0.3344
0.3076
0.2832
0.2608
0.2403
0.2214
0.2041
0.1880
0.1732
0.1595
0.1468
0.1349
0.1238
0.1134
0.1036
0.0943
0.0855
0.0769
0.0684
0.0597
0.0499
0.0326
Entalpia, Btu/lb
Líquido
–32.027
–30.571
–29.121
–27.677
–26.235
–24.796
–23.359
–21.921
–20.484
–19.045
–17.604
–16.161
–14.716
–13.266
–11.813
–10.356
–8.894
–7.427
–5.954
–4.475
–3.625
–2.990
–1.499
0.000
1.506
3.020
4.541
6.071
7.610
9.158
10.716
12.284
13.862
15.452
17.052
18.665
20.290
21.929
23.581
25.249
26.931
28.630
30.346
32.080
33.834
35.609
37.406
39.228
41.076
42.952
44.860
46.803
48.784
50.809
52.885
55.018
57.221
59.509
61.903
64.439
67.182
70.265
74.107
83.010
Vapor
67.009
67.711
68.416
69.126
69.838
70.554
71.272
71.993
72.716
73.440
74.166
74.892
75.619
76.346
77.073
77.800
78.525
79.248
79.970
80.690
81.101
81.406
82.119
82.829
83.534
84.235
84.931
85.621
86.304
86.981
87.651
88.313
88.966
89.610
90.245
90.868
91.480
92.079
92.664
93.234
93.788
94.324
94.840
95.336
95.808
96.255
96.675
97.065
97.421
97.740
98.019
98.251
98.431
98.551
98.600
98.568
98.435
98.177
97.759
97.125
96.173
94.697
92.081
83.010
Entropía,
Btu/lb·°F
Líquido
Vapor
–0.08831
0.23154
–0.08365
0.22872
–0.07908
0.22607
–0.07460
0.22358
–0.07019
0.22125
–0.06586
0.21906
–0.06160
0.21701
–0.05740
0.21509
–0.05326
0.21328
–0.04918
0.21159
–0.04515
0.21001
–0.04117
0.20852
–0.03723
0.20713
–0.03335
0.20583
–0.02950
0.20462
–0.02569
0.20348
–0.02192
0.20242
–0.01819
0.20143
–0.01449
0.20050
–0.01082
0.19963
–0.00873
0.19916
–0.00719
0.19882
–0.00358
0.19807
0.00000
0.19737
0.00355
0.19671
0.00708
0.19610
0.01058
0.19553
0.01407
0.19500
0.01753
0.19450
0.02097
0.19404
0.02439
0.19360
0.02779
0.19319
0.03118
0.19281
0.03455
0.19245
0.03791
0.19211
0.04126
0.19179
0.04459
0.19148
0.04791
0.19118
0.05123
0.19089
0.05454
0.19061
0.05784
0.19032
0.06114
0.19004
0.06444
0.18976
0.06773
0.18946
0.07103
0.18916
0.07434
0.18884
0.07764
0.18850
0.08096
0.18814
0.08429
0.18775
0.08764
0.18732
0.09101
0.18686
0.09441
0.18634
0.09784
0.18576
0.10130
0.18511
0.10482
0.18438
0.10840
0.18354
0.11206
0.18256
0.11583
0.18141
0.11973
0.18003
0.12382
0.17833
0.12821
0.17616
0.13311
0.17318
0.13918
0.16842
0.15339
0.15339
Calor Específico cp,
Btu/lb·°F
Líquido
Vapor
0.2919
0.1470
0.2904
0.1487
0.2893
0.1504
0.2885
0.1522
0.2879
0.1540
0.2876
0.1558
0.2874
0.1576
0.2874
0.1595
0.2875
0.1614
0.2878
0.1633
0.2882
0.1652
0.2887
0.1672
0.2893
0.1692
0.2900
0.1712
0.2908
0.1733
0.2917
0.1754
0.2926
0.1776
0.2937
0.1798
0.2948
0.1821
0.2960
0.1844
0.2967
0.1858
0.2972
0.1868
0.2985
0.1893
0.30000
0.1918
0.3014
0.1944
0.3030
0.1971
0.3046
0.1998
0.3063
0.2026
0.3081
0.2056
0.3100
0.2086
0.3119
0.2117
0.3140
0.2149
0.3161
0.2183
0.3184
0.2218
0.3208
0.2254
0.3233
0.2291
0.3260
0.2330
0.3288
0.2371
0.3318
0.2414
0.3350
0.2460
0.3384
0.2508
0.3421
0.2560
0.3460
0.2616
0.3503
0.2676
0.3549
0.2742
0.3599
0.2814
0.3654
0.2894
0.3715
0.2983
0.3783
0.3083
0.3858
0.3196
0.3944
0.3325
0.4043
0.3475
0.4157
0.3650
0.4291
0.3858
0.4453
0.4112
0.4652
0.4427
0.4904
0.4833
0.5237
0.5375
0.5700
0.6142
0.6399
0.7313
0.7590
0.9326
1.0130
1.3606
1.9550
2.8693


cp/cv
Vapor
1.1650
1.1637
1.1626
1.1616
1.1607
1.1599
1.1593
1.1588
1.1584
1.1581
1.1580
1.1581
1.1583
1.1586
1.1592
1.1599
1.1607
1.1618
1.1631
1.1646
1.1655
1.1663
1.1682
1.1704
1.1728
1.1755
1.1785
1.1818
1.1854
1.1894
1.1938
1.1986
1.2038
1.2095
1.2157
1.2226
1.2301
1.2384
1.2476
1.2577
1.2690
1.2816
1.2956
1.3113
1.3289
1.3488
1.3713
1.3970
1.4265
1.4606
1.5003
1.5471
1.6029
1.6706
1.7541
1.8597
1.9972
2.1831
2.4480
2.8546
3.5556
5.0420
10.2379

bPunto de ebullición normal
*Temperaturas en escala ITS-90
**Pequeñas desviaciones de comportamiento azeotrópico que ocurren en algunas condiciones; presiones c̯Punto crítico
tabuladas son promedios de presiones de puntos de burbuja y rocío
182
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Temp.*°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.11 (I-P) R-507A [R-125/143a (50/50)] Propiedades de Líquido Saturado y
Vapor Saturado [2013F, Ch 30, Tbl R-507A]
09.fm Page 183 Thursday, March 3, 2016 12:46 PM
Temp.,* °C
Presión,**
MPa
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.11 (SI)
R-507A [R-125/143a (50/50)] Propiedades de Líquido Saturado y
Vapor Saturado [2013F, Ch 30, Tbl R-507A]
Densidad,
kg/m3
Líquido
Volumen,
m3/kg
Vapor
–100
0.00295
1476.9
4.92920
–95
0.00458
1461.7
3.25360
–90
0.00693
1446.8
2.20850
–85
0.01019
1431.9
1.53750
–80
0.01464
1417.1
1.09510
–75
0.02058
1402.3
0.79638
–70
0.02836
1387.4
0.59012
–65
0.03837
1372.5
0.44482
–60
0.05105
1357.4
0.34056
–55
0.06688
1342.3
0.26444
–50
0.08638
1326.9
0.20801
–48
0.09533
1320.7
0.18960
–46.74b
0.10132
1316.8
0.17902
–46
0.10499
1314.5
0.17313
–44
0.11541
1308.2
0.15836
–42
0.12662
1301.9
0.14510
–40
0.13867
1295.6
0.13317
–38
0.15159
1289.2
0.12240
–36
0.16542
1282.8
0.11268
–34
0.18022
1276.3
0.10388
–32
0.19602
1269.7
0.09590
–30
0.21287
1263.2
0.08865
–28
0.23081
1256.5
0.08205
–26
0.24989
1249.8
0.07604
–24
0.27016
1243.1
0.07055
–22
0.29167
1236.3
0.06553
–20
0.31446
1229.4
0.06094
–18
0.33858
1222.5
0.05673
–16
0.36408
1215.4
0.05286
–14
0.39102
1208.4
0.04931
–12
0.41945
1201.2
0.04603
–10
0.44941
1193.9
0.04301
–8
0.48096
1186.6
0.04023
–6
0.51416
1179.2
0.03765
–4
0.54906
1171.7
0.03527
–2
0.58571
1164.0
0.03306
0
0.62417
1156.3
0.03101
2
0.66450
1148.5
0.02910
4
0.70676
1140.5
0.02733
6
0.75099
1132.4
0.02568
8
0.79728
1124.2
0.02415
10
0.84566
1115.9
0.02271
12
0.89622
1107.4
0.02138
14
0.94900
1098.7
0.02012
16
1.00410
1089.9
0.01895
18
1.06150
1080.9
0.01785
20
1.12140
1071.7
0.01683
22
1.18370
1062.4
0.01586
24
1.24860
1052.8
0.01495
26
1.31610
1043.0
0.01410
28
1.38640
1032.9
0.01329
30
1.45940
1022.6
0.01253
32
1.53520
1011.9
0.01182
34
1.61400
1001.0
0.01114
36
1.69580
989.7
0.01050
38
1.78070
978.1
0.00989
40
1.86880
966.0
0.00932
42
1.96020
953.5
0.00877
44
2.05490
940.5
0.00825
46
2.15310
926.9
0.00776
48
2.25480
912.7
0.00728
50
2.36030
897.7
0.00683
55
2.64090
856.2
0.00578
60
2.94760
806.1
0.00480
65
3.28380
739.1
0.00384
70
3.65570
599.6
0.00260
70.62c
3.70500
490.8
0.00204
* Temperaturas en escala ITS-90
** Pequeñas desviaciones de comportamiento azeotrópico que ocurre en algunas condiciones: presiones
tabuladas son promedios de presiones de punto de burbuja y rocío
Calor Específico cp,
cp/cv
kJ/(kgyK)
Vapor
Líquido
Vapor
1.219
0.618
1.164
1.210
0.631
1.162
1.205
0.644
1.161
1.203
0.658
1.159
1.203
0.672
1.159
1.205
0.686
1.158
1.208
0.701
1.158
1.213
0.716
1.159
1.220
0.732
1.160
1.227
0.749
1.161
1.235
0.766
1.164
1.239
0.773
1.165
1.241
0.777
1.166
1.243
0.780
1.166
1.247
0.787
1.167
1.251
0.795
1.169
1.255
0.803
1.170
1.259
0.810
1.172
1.264
0.818
1.174
1.269
0.826
1.176
1.274
0.835
1.178
1.279
0.843
1.180
1.284
0.852
1.183
1.289
0.861
1.186
1.295
0.870
1.188
1.301
0.879
1.191
1.307
0.888
1.195
1.313
0.898
1.198
1.319
0.908
1.202
1.326
0.918
1.206
1.333
0.929
1.210
1.340
0.940
1.214
1.348
0.951
1.219
1.355
0.962
1.224
1.363
0.974
1.230
1.372
0.987
1.236
1.381
0.999
1.242
1.390
1.012
1.249
1.399
1.026
1.256
1.410
1.040
1.264
1.420
1.055
1.272
1.431
1.071
1.282
1.443
1.088
1.291
1.455
1.105
1.302
1.468
1.124
1.314
1.482
1.144
1.327
1.497
1.165
1.341
1.513
1.188
1.356
1.530
1.212
1.372
1.548
1.239
1.391
1.568
1.268
1.411
1.589
1.299
1.433
1.612
1.333
1.458
1.637
1.371
1.485
1.664
1.413
1.516
1.695
1.459
1.551
1.729
1.511
1.591
1.767
1.570
1.636
1.811
1.638
1.689
1.860
1.716
1.750
1.918
1.807
1.823
1.985
1.915
1.910
2.225
2.304
2.228
2.677
3.060
2.855
3.940
5.190
4.625
31.960
44.630
36.780



b Punto de ebullición normal
c Punto critic
183
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
Entropía,
kJ/(kgyK)
Líquido
Vapor
0.4323
1.7579
0.4669
1.7377
0.5003
1.7197
0.5327
1.7036
0.5642
1.6893
0.5950
1.6766
0.6250
1.6652
0.6545
1.6552
0.6833
1.6463
0.7116
1.6384
0.7395
1.6314
0.7505
1.6288
0.7574
1.6273
0.7615
1.6264
0.7724
1.6241
0.7832
1.6219
0.7940
1.6198
0.8047
1.6178
0.8153
1.6159
0.8260
1.6141
0.8365
1.6123
0.8470
1.6107
0.8575
1.6092
0.8679
1.6077
0.8783
1.6063
0.8886
1.6049
0.8989
1.6037
0.9091
1.6024
0.9193
1.6013
0.9295
1.6001
0.9397
1.5991
0.9498
1.5980
0.9599
1.5971
0.9699
1.5961
0.9800
1.5952
0.9900
1.5943
1.0000
1.5934
1.0100
1.5925
1.0199
1.5917
1.0299
1.5908
1.0398
1.5900
1.0498
1.5891
1.0597
1.5883
1.0696
1.5874
1.0796
1.5865
1.0895
1.5856
1.0995
1.5846
1.1094
1.5836
1.1194
1.5826
1.1294
1.5815
1.1394
1.5804
1.1495
1.5792
1.1595
1.5779
1.1697
1.5765
1.1799
1.5750
1.1901
1.5734
1.2004
1.5717
1.2108
1.5698
1.2213
1.5678
1.2320
1.5655
1.2427
1.5631
1.2536
1.5603
1.2818
1.5519
1.3120
1.5401
1.3465
1.5215
1.4007
1.4740
1.4358
1.4358
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Entalpia,
kJ/kg
Líquido
Vapor
74.41
303.90
80.48
306.85
86.51
309.83
92.53
312.83
98.54
315.85
104.57
318.88
110.60
321.92
116.66
324.96
122.74
328.00
128.87
331.03
135.03
334.05
137.51
335.25
139.07
336.01
139.99
336.45
142.48
337.65
144.99
338.84
147.49
340.03
150.01
341.21
152.54
342.38
155.08
343.55
157.63
344.72
160.18
345.88
162.75
347.03
165.33
348.17
167.92
349.30
170.52
350.43
173.13
351.54
175.76
352.65
178.39
353.75
181.04
354.83
183.71
355.91
186.39
356.97
189.08
358.02
191.78
359.06
194.51
360.08
197.25
361.08
200.00
362.07
202.77
363.05
205.56
364.00
208.37
364.94
211.20
365.85
214.04
366.75
216.91
367.61
219.80
368.46
222.71
369.28
225.65
370.07
228.61
370.83
231.60
371.55
234.61
372.25
237.66
372.91
240.73
373.52
243.84
374.10
246.98
374.63
250.16
375.11
253.39
375.54
256.65
375.91
259.96
376.22
263.33
376.46
266.74
376.61
270.23
376.68
273.78
376.66
277.41
376.52
286.91
375.54
297.28
373.26
309.30
368.44
328.32
353.47
340.45
340.45
09.fm Page 184 Thursday, March 3, 2016 12:46 PM
184
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.9 (I-P) Diagrama Presión-Entalpia para Refrigerante 1234yf [2012F, Ch 30, Fig 12]
09.fm Page 185 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
185
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.9 (SI) Diagrama Presión-Entalpia para Refrigerante 1234yf [2012F, Ch 30, Fig 12]
09.fm Page 186 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
Presión,
psia
–60
–55
–50
–45
–40
–35
–30
–25
–21.07b
–20
–15
–10
–5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
202.46c
5.111
5.932
6.855
7.889
9.046
10.333
11.761
13.341
14.696
15.084
17.001
19.104
21.404
23.914
26.647
29.615
32.831
36.309
40.062
44.105
48.451
53.116
58.113
63.459
69.167
75.255
81.737
88.629
95.949
103.71
111.94
120.64
129.84
139.55
149.80
160.60
171.97
183.93
196.51
209.72
223.59
238.13
253.39
269.37
286.11
303.64
321.99
341.19
361.28
382.32
404.35
427.45
451.72
477.33
490.55
Densidad,
lb/ft3
Líquido
82.49
82.03
81.58
81.11
80.65
80.18
79.71
79.23
78.85
78.75
78.26
77.77
77.28
76.78
76.27
75.76
75.24
74.72
74.19
73.65
73.11
72.55
71.99
71.42
70.84
70.25
69.65
69.04
68.42
67.78
67.14
66.47
65.80
65.10
64.39
63.66
62.92
62.14
61.35
60.52
59.66
58.77
57.83
56.84
55.80
54.68
53.49
52.21
50.80
49.24
47.47
45.39
42.73
38.53
29.69
*Temperaturas en escala ITS-90
Volumen,
ft3/lb
Vapor
7.1955
6.2622
5.4710
4.7974
4.2215
3.7271
3.3012
2.9329
2.6781
2.6132
2.3349
2.0917
1.8786
1.6913
1.5262
1.3802
1.2508
1.1357
1.0332
0.9416
0.8596
0.7860
0.7198
0.6601
0.6062
0.5573
0.5130
0.4728
0.4361
0.4027
0.3721
0.3441
0.3185
0.2949
0.2732
0.2532
0.2347
0.2176
0.2017
0.1870
0.1733
0.1606
0.1487
0.1375
0.1270
0.1172
0.1078
0.0990
0.0905
0.0823
0.0743
0.0662
0.0578
0.0475
0.0337
Entalpia,
Btu/lb
Líquido
Vapor
–5.458
76.593
–4.109
77.395
–2.749
78.198
–1.380
79.002
0.000
79.808
1.390
80.614
2.790
81.420
4.200
82.226
5.315
82.859
5.621
83.032
7.053
83.837
8.495
84.641
9.948
85.444
11.412
86.244
12.887
87.043
14.374
87.839
15.871
88.632
17.381
89.422
18.902
90.208
20.434
90.989
21.979
91.765
23.536
92.536
25.106
93.301
26.688
94.059
28.283
94.810
29.891
95.552
31.513
96.285
33.149
97.008
34.799
97.720
36.463
98.420
38.142
99.106
39.837
99.779
41.548
100.435
43.275
101.075
45.021
101.696
46.784
102.296
48.568
102.874
50.373
103.428
52.201
103.955
54.054
104.452
55.935
104.916
57.845
105.342
59.789
105.726
61.769
106.061
63.792
106.340
65.861
106.554
67.986
106.690
70.175
106.731
72.445
106.653
74.816
106.421
77.328
105.976
80.050
105.213
83.145
103.888
87.241
101.103
93.995
93.995
b
Entropía,
Btu/lby°F
Líquido
Vapor
–0.01330
0.19200
–0.00995
0.19146
–0.00662
0.19097
–0.00330
0.19055
0.00000
0.19017
0.00328
0.18984
0.00655
0.18956
0.00981
0.18932
0.01236
0.18916
0.01305
0.18912
0.01628
0.18896
0.01949
0.18883
0.02269
0.18874
0.02588
0.18868
0.02906
0.18865
0.03223
0.18865
0.03538
0.18867
0.03853
0.18872
0.04166
0.18878
0.04479
0.18887
0.04790
0.18898
0.05101
0.18910
0.05411
0.18924
0.05720
0.18939
0.06029
0.18955
0.06337
0.18972
0.06644
0.18989
0.06951
0.19007
0.07257
0.19025
0.07563
0.19044
0.07869
0.19062
0.08174
0.19079
0.08479
0.19096
0.08784
0.19112
0.09090
0.19126
0.09395
0.19140
0.09701
0.19151
0.10008
0.19160
0.10315
0.19167
0.10624
0.19171
0.10934
0.19171
0.11246
0.19167
0.11561
0.19158
0.11879
0.19144
0.12200
0.19122
0.12526
0.19093
0.12857
0.19053
0.13196
0.19001
0.13543
0.18933
0.13903
0.18844
0.14281
0.18725
0.14688
0.18561
0.15147
0.18315
0.15752
0.17853
0.16763
0.16763
Punto de ebullición normal
Calor específico, cp
Btu/lby°F
Líquido
Vapor
0.2688
0.1776
0.2707
0.1796
0.2727
0.1817
0.2746
0.1838
0.2766
0.1859
0.2787
0.1880
0.2807
0.1903
0.2828
0.1925
0.2844
0.1943
0.2848
0.1948
0.2870
0.1971
0.2891
0.1995
0.2912
0.2019
0.2934
0.2043
0.2956
0.2068
0.2979
0.2094
0.3001
0.2120
0.3024
0.2147
0.3048
0.2174
0.3072
0.2202
0.3096
0.2231
0.3121
0.2261
0.3147
0.2291
0.3173
0.2323
0.3199
0.2355
0.3227
0.2389
0.3255
0.2425
0.3285
0.2462
0.3315
0.2501
0.3346
0.2543
0.3379
0.2587
0.3413
0.2635
0.3450
0.2686
0.3488
0.2742
0.3530
0.2802
0.3574
0.2867
0.3623
0.2940
0.3676
0.3019
0.3735
0.3107
0.3801
0.3206
0.3875
0.3318
0.3959
0.3446
0.4055
0.3594
0.4167
0.3767
0.4300
0.3974
0.4459
0.4227
0.4655
0.4544
0.4906
0.4956
0.5241
0.5513
0.5717
0.6314
0.6458
0.7571
0.7788
0.9837
1.094
1.5170
—
—


c
cpcv
Vapor
1.1241
1.1243
1.1247
1.1252
1.1258
1.1265
1.1274
1.1285
1.1294
1.1297
1.1310
1.1325
1.1342
1.1361
1.1381
1.1404
1.1429
1.1457
1.1486
1.1519
1.1555
1.1594
1.1637
1.1685
1.1736
1.1793
1.1856
1.1926
1.2002
1.2087
1.2181
1.2286
1.2402
1.2533
1.2679
1.2843
1.3028
1.3239
1.3479
1.3756
1.4077
1.4453
1.4898
1.5432
1.6082
1.6891
1.7922
1.9275
2.1127
2.3809
2.8031
3.5641
5.3442
—

Punto crítico
186
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,* °F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.12 (I-P) R-1234yf (2,3,3,3-Tetrafluoroprop Propiedades de Líquido
Saturado y Vapor Saturado [2013F, Ch 30, Tbl R-1234yf]
09.fm Page 187 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.12 (SI) R-1234yf (2,3,3,3-Tetrafluoroprop-1-ene) Propiedades de Líquido
Saturado y Vapor Saturado [2013F, Ch 30, Tbl R-1234yf]
–50
–45
–40
–35
–30
–29.49b
–28
–26
–24
–22
–20
–18
–16
–14
–12
–10
–8
–6
–4
–2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
85
90
94.70c
0.03742
0.04862
0.06237
0.07904
0.09906
0.10132
0.10810
0.11778
0.12812
0.13916
0.15092
0.16344
0.17676
0.19090
0.20590
0.22178
0.23860
0.25637
0.27514
0.29495
0.31582
0.33780
0.36092
0.38523
0.41075
0.43753
0.46561
0.49503
0.52583
0.55804
0.59172
0.62690
0.66363
0.70194
0.74189
0.78351
0.82686
0.87197
0.91890
0.96769
1.0184
1.0711
1.1257
1.1825
1.2413
1.3023
1.3656
1.4311
1.4989
1.5692
1.6419
1.7171
1.7949
1.8754
1.9586
2.0445
2.1334
2.2252
2.3201
2.4181
2.5194
2.7879
3.0803
3.3822
Densidad,
kg/m3
Líquido
1318.4
1305.2
1291.9
1278.3
1264.5
1263.1
1259.0
1253.4
1247.7
1242.0
1236.3
1230.5
1224.7
1218.8
1212.9
1207.0
1200.9
1194.9
1188.7
1182.5
1176.3
1170.0
1163.6
1157.2
1150.6
1144.0
1137.4
1130.6
1123.8
1116.9
1109.9
1102.8
1095.5
1088.2
1080.8
1073.3
1065.7
1057.9
1050.0
1042.0
1033.8
1025.5
1017.0
1008.3
999.4
990.4
981.1
971.6
961.8
951.7
941.3
930.6
919.5
907.9
895.8
883.2
870.0
856.1
841.4
825.7
809.0
760.4
694.1
475.6
*Temperaturas en escala ITS-90
Volumen,
m3/kg
Vapor
0.42472
0.33259
0.26354
0.21110
0.17079
0.16719
0.15732
0.14512
0.13404
0.12398
0.11482
0.10647
0.09884
0.09187
0.08548
0.07962
0.07424
0.06930
0.06474
0.06054
0.05667
0.05309
0.04977
0.04670
0.04385
0.04121
0.03875
0.03646
0.03433
0.03235
0.03049
0.02876
0.02714
0.02562
0.02420
0.02287
0.02162
0.02044
0.01934
0.01830
0.01732
0.01639
0.01552
0.01469
0.01392
0.01318
0.01248
0.01182
0.01119
0.01059
0.01002
0.00948
0.00897
0.00848
0.00801
0.00756
0.00712
0.00671
0.00631
0.00592
0.00555
0.00464
0.00372
0.00210
Entalpia,
kJ/kg
Liquido
Vapor
139.63
329.85
145.31
333.21
151.07
336.58
156.90
339.95
162.81
343.32
163.42
343.67
165.20
344.67
167.60
346.02
170.01
347.36
172.43
348.71
174.87
350.05
177.32
351.39
179.79
352.73
182.27
354.06
184.76
355.39
187.26
356.72
189.78
358.04
192.31
359.36
194.86
360.68
197.42
361.99
200.00
363.29
202.59
364.59
205.20
365.88
207.82
367.16
210.45
368.44
213.10
369.70
215.77
370.96
218.45
372.21
221.15
373.45
223.87
374.67
226.60
375.89
229.34
377.09
232.11
378.28
234.89
379.45
237.69
380.61
240.51
381.75
243.35
382.87
246.21
383.98
249.09
385.06
251.98
386.13
254.90
387.17
257.84
388.19
260.81
389.18
263.80
390.14
266.81
391.08
269.85
391.98
272.92
392.85
276.02
393.68
279.15
394.48
282.32
395.23
285.53
395.93
288.77
396.58
292.06
397.18
295.39
397.71
298.78
398.18
302.22
398.57
305.72
398.87
309.30
399.07
312.95
399.16
316.69
399.11
320.54
398.90
330.81
397.40
342.79
393.32
369.55
369.55
b
Entropía,
kJ/(kgyK)
Líquido
Vapor
0.7573
1.6098
0.7825
1.6060
0.8074
1.6031
0.8321
1.6007
0.8566
1.5990
0.8591
1.5988
0.8663
1.5984
0.8760
1.5980
0.8857
1.5976
0.8954
1.5973
0.9050
1.5970
0.9146
1.5968
0.9242
1.5967
0.9338
1.5967
0.9433
1.5967
0.9528
1.5968
0.9623
1.5969
0.9717
1.5970
0.9812
1.5973
0.9906
1.5975
1.0000
1.5978
1.0094
1.5981
1.0187
1.5985
1.0281
1.5989
1.0374
1.5993
1.0467
1.5998
1.0560
1.6003
1.0653
1.6008
1.0746
1.6013
1.0838
1.6018
1.0931
1.6024
1.1023
1.6029
1.1115
1.6034
1.1208
1.6040
1.1300
1.6045
1.1392
1.6051
1.1484
1.6056
1.1576
1.6061
1.1668
1.6066
1.1759
1.6071
1.1851
1.6075
1.1943
1.6079
1.2035
1.6083
1.2128
1.6087
1.2220
1.6089
1.2312
1.6092
1.2405
1.6094
1.2498
1.6095
1.2592
1.6095
1.2685
1.6095
1.2779
1.6093
1.2874
1.6091
1.2969
1.6087
1.3065
1.6082
1.3162
1.6076
1.3260
1.6068
1.3359
1.6058
1.3459
1.6045
1.3561
1.6030
1.3664
1.6011
1.3770
1.5989
1.4049
1.5909
1.4370
1.5762
1.5087
1.5087
Punto de ebullición normal
Calor Específico cp,
kJ/(kgyK)
Líquido
Vapor
1.128
0.746
1.143
0.762
1.157
0.778
1.173
0.794
1.188
0.811
1.190
0.813
1.195
0.818
1.201
0.825
1.207
0.832
1.214
0.839
1.220
0.847
1.227
0.854
1.234
0.862
1.240
0.869
1.247
0.877
1.254
0.885
1.261
0.893
1.268
0.901
1.275
0.909
1.282
0.918
1.289
0.926
1.297
0.935
1.304
0.944
1.312
0.953
1.320
0.962
1.327
0.972
1.335
0.982
1.344
0.992
1.352
1.002
1.361
1.013
1.369
1.024
1.378
1.035
1.387
1.047
1.397
1.060
1.407
1.073
1.417
1.086
1.427
1.101
1.438
1.116
1.449
1.132
1.461
1.149
1.473
1.167
1.486
1.186
1.500
1.207
1.515
1.229
1.531
1.252
1.548
1.277
1.566
1.305
1.586
1.335
1.607
1.367
1.631
1.403
1.656
1.442
1.685
1.485
1.717
1.534
1.752
1.589
1.792
1.651
1.837
1.724
1.890
1.808
1.951
1.907
2.025
2.028
2.114
2.176
2.227
2.364
2.702
3.168
4.186
5.688


c
cp/cv
Vapor
1.124
1.125
1.126
1.127
1.129
1.129
1.130
1.131
1.132
1.133
1.135
1.136
1.137
1.139
1.141
1.142
1.144
1.146
1.149
1.151
1.153
1.156
1.159
1.162
1.165
1.168
1.172
1.176
1.180
1.185
1.190
1.195
1.201
1.207
1.213
1.220
1.228
1.236
1.245
1.254
1.265
1.276
1.289
1.302
1.317
1.333
1.351
1.371
1.393
1.418
1.445
1.477
1.512
1.553
1.600
1.655
1.719
1.797
1.891
2.009
2.158
2.803
4.820

Punto crítico
187
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
Presión,
MPa
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,* °C
09.fm Page 188 Thursday, March 3, 2016 12:46 PM
188
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 9.10 (I-P) Diagrama de Presión-Entalpia para Refrigerante 1234ze(E) [2013F, Ch 30, Fig 13]
09.fm Page 189 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos Refrigerantes
189
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 9.10 (SI) Diagrama de Presión-Entalpia para Refrigerante 1234ze(E) [2013F, Ch 30, Fig 13]
09.fm Page 190 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
Presión,
psia
Densidad,
lb/ft3
Líquido
Volumen,
ft3/lb
Vapor
–60
–55
–50
–45
–40
–35
–30
–25
–20
–15
–10
–5
–2.13b
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
190
195
200
205
210
215
220
225
228.87c
2.845
3.352
3.930
4.588
5.332
6.170
7.112
8.167
9.343
10.651
12.100
13.702
14.696
15.467
17.406
19.531
24.386
27.141
30.132
33.372
36.874
40.651
44.719
49.090
53.781
58.805
64.178
69.914
76.031
82.543
89.468
96.821
104.62
112.88
121.62
130.86
140.62
150.91
161.75
173.17
185.19
197.81
211.08
225.00
239.60
254.91
270.94
287.74
305.31
323.71
342.95
363.09
384.16
406.20
429.29
453.47
478.86
505.59
527.39
85.94
85.51
85.08
84.64
84.20
83.75
83.31
82.86
82.40
81.94
81.48
81.02
80.75
80.55
80.07
79.59
78.62
78.13
77.63
77.12
76.61
76.09
75.56
75.03
74.49
73.95
73.39
72.83
72.26
71.68
71.09
70.49
69.87
69.25
68.62
67.97
67.30
66.62
65.92
65.21
64.46
63.70
62.90
62.08
61.22
60.32
59.38
58.39
57.36
56.26
55.09
53.84
52.47
50.96
49.25
47.25
44.75
41.14
30.54
13.049
11.195
9.6481
8.3497
7.2553
6.3287
5.5409
4.8682
4.2916
3.7955
3.3671
2.9958
2.8048
2.6730
2.3914
2.1449
1.7381
1.5699
1.4211
1.2890
1.1714
1.0665
0.9727
0.8887
0.8132
0.7452
0.6839
0.6285
0.5783
0.5327
0.4913
0.4535
0.4191
0.3876
0.3588
0.3324
0.3081
0.2857
0.2651
0.2460
0.2284
0.2121
0.1970
0.1829
0.1698
0.1575
0.1461
0.1353
0.1252
0.1157
0.1067
0.0981
0.0899
0.0819
0.0742
0.0664
0.0584
0.0493
0.0327
*Temperaturas en escala ITS-90
Entalpia,
Btu/lb
Líquido
Vapor
–5.694
85.631
86.455
–4.282
–2.862
87.280
88.107
–1.435
0.000
88.935
1.443
89.763
2.893
90.592
4.352
91.421
5.819
92.250
7.294
93.078
8.777
93.906
10.268
94.732
11.130
95.206
11.768
95.556
13.277
96.379
14.794
97.199
17.855
98.832
19.399
99.643
20.953
100.451
22.516
101.255
24.088
102.055
25.670
102.849
27.262
103.638
28.864
104.422
30.477
105.199
32.100
105.970
33.733
106.733
35.378
107.488
37.034
108.235
38.702
108.973
40.381
109.701
42.073
110.418
43.778
111.124
45.497
111.818
47.229
112.498
48.977
113.164
50.741
113.814
52.523
114.447
54.323
115.062
56.142
115.655
57.983
116.227
59.847
116.773
61.735
117.291
63.648
117.778
65.590
118.230
67.561
118.643
69.564
119.012
71.602
119.330
73.679
119.590
75.802
119.783
77.977
119.896
80.217
119.913
82.537
119.810
84.962
119.553
87.528
119.088
90.298
118.319
93.404
117.046
97.247
114.672
105.815
105.815
b
Entropía,
Btu/lby°F
Líquido
Vapor
–0.01389
0.21461
0.21385
–0.01038
–0.00690
0.21314
0.21250
–0.00344
0.00000
0.21192
0.00341
0.21139
0.00680
0.21091
0.01017
0.21049
0.01352
0.21011
0.01685
0.20977
0.02016
0.20948
0.02345
0.20922
0.02534
0.20909
0.02672
0.20900
0.02998
0.20882
0.03322
0.20867
0.03964
0.20846
0.04283
0.20839
0.04600
0.20836
0.04916
0.20834
0.05231
0.20835
0.05544
0.20837
0.05856
0.20842
0.06167
0.20848
0.06476
0.20855
0.06785
0.20864
0.07092
0.20874
0.07398
0.20885
0.07704
0.20897
0.08008
0.20910
0.08312
0.20923
0.08615
0.20937
0.08917
0.20950
0.09219
0.20964
0.09520
0.20978
0.09821
0.20991
0.10122
0.21003
0.10424
0.21015
0.10725
0.21025
0.11027
0.21035
0.11329
0.21042
0.11633
0.21047
0.11937
0.21050
0.12243
0.21049
0.12551
0.21046
0.12860
0.21037
0.13171
0.21024
0.13485
0.21006
0.13803
0.20980
0.14124
0.20946
0.14450
0.20902
0.14783
0.20846
0.15125
0.20775
0.15479
0.20683
0.15851
0.20564
0.16249
0.20402
0.16693
0.20171
0.17239
0.19784
0.18470
0.18470
Punto de ebullición normal
Calor Específico, cp
Btu/lby°F
Líquido
Vapor
0.2816
0.1749
0.2831
0.1765
0.2846
0.1782
0.2861
0.1798
0.2876
0.1815
0.2891
0.1832
0.2907
0.1850
0.2923
0.1868
0.2939
0.1886
0.2955
0.1904
0.2971
0.1923
0.2988
0.1943
0.2997
0.1954
0.3005
0.1963
0.3022
0.1983
0.3039
0.2004
0.3074
0.2047
0.3092
0.2069
0.3111
0.2093
0.3130
0.2116
0.3149
0.2141
0.3168
0.2166
0.3188
0.2192
0.3209
0.2218
0.3230
0.2246
0.3251
0.2274
0.3273
0.2304
0.3296
0.2335
0.3320
0.2367
0.3344
0.2400
0.3369
0.2435
0.3396
0.2471
0.3424
0.2510
0.3454
0.2550
0.3486
0.2593
0.3520
0.2638
0.3557
0.2686
0.3597
0.2738
0.3641
0.2793
0.3689
0.2853
0.3740
0.2918
0.3797
0.2990
0.3859
0.3070
0.3927
0.3159
0.4002
0.3261
0.4085
0.3379
0.4179
0.3518
0.4286
0.3684
0.4412
0.3884
0.4564
0.4131
0.4754
0.4442
0.4999
0.4846
0.5327
0.5391
0.5791
0.6165
0.6495
0.7354
0.7699
0.9416
1.027
1.3857
—
—


c
cpcv
Vapor
1.1187
1.1186
1.1186
1.1188
1.1190
1.1193
1.1198
1.1204
1.1210
1.1219
1.1228
1.1239
1.1246
1.1251
1.1265
1.1280
1.1316
1.1336
1.1359
1.1384
1.1410
1.1440
1.1471
1.1506
1.1544
1.1584
1.1629
1.1677
1.1730
1.1787
1.1850
1.1918
1.1993
1.2076
1.2166
1.2266
1.2376
1.2498
1.2635
1.2789
1.2962
1.3160
1.3387
1.3649
1.3956
1.4316
1.4745
1.5260
1.5889
1.6670
1.7661
1.8954
2.0709
2.3216
2.7077
3.3761
4.8045
—

Punto crítico
190
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temp.,* °F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.13 (I-P) R-1234ze(E) (Trans,3,3,3Tetrafluoropropeno) Propiedades de
Líquido Saturado y Vapor Saturado [2013F, Ch 30, Tbl 1234ze(E)]
09.fm Page 191 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.13 (SI) R-1234ze(E) (Trans-1,3,3,3-Tetrafluoropropeno) Propiedades de
Líquido Saturado y Vapor Saturado [2013F, Ch 30, Tbl R-1234ze(E)]
Temp.,* °C
*Temperatura en escala ITS-90
Volumen,
m3/kg
Vapor
0.76577
0.58495
0.45294
0.35512
0.28166
0.22578
0.18277
0.1751
0.16838
0.15535
0.14351
0.13275
0.12296
0.11403
0.10587
0.0984
0.09157
0.0853
0.07954
0.07425
0.06937
0.06487
0.06072
0.05689
0.05334
0.05006
0.04701
0.04418
0.04155
0.0391
0.03682
0.0347
0.03272
0.03087
0.02914
0.02752
0.026
0.02458
0.02324
0.02199
0.02081
0.0197
0.01866
0.01768
0.01675
0.01587
0.01504
0.01426
0.01352
0.01282
0.01215
0.01152
0.01092
0.01035
0.0098
0.00929
0.00879
0.00832
0.00722
0.00623
0.00531
0.00444
0.00354
0.00204
Entalpia,
kJ/kg
Vapor
349.66
353.11
356.57
360.04
363.51
366.97
370.43
371.15
371.81
373.19
374.56
375.93
377.3
378.67
380.03
381.39
382.74
384.09
385.43
386.77
388.1
389.43
390.75
392.06
393.37
394.66
395.95
397.23
398.5
399.77
401.02
402.26
403.49
404.71
405.91
407.1
408.28
409.44
410.59
411.72
412.83
413.92
414.99
416.05
417.07
418.08
419.06
420.01
420.93
421.82
422.67
423.48
424.26
424.98
425.66
426.29
426.85
427.35
428.27
428.59
428.03
426.05
421.1
395.81
Liquid
137.92
143.85
149.85
155.9
162.01
168.18
174.41
175.72
176.92
179.44
181.97
184.52
187.07
189.63
192.21
194.79
197.39
200
202.62
205.25
207.89
210.55
213.22
215.89
218.59
221.29
224.01
226.74
229.48
232.23
235
237.79
240.58
243.4
246.22
249.07
251.92
254.8
257.69
260.6
263.53
266.48
269.44
272.43
275.44
278.48
281.54
284.62
287.74
290.88
294.05
297.26
300.49
303.76
307.07
310.42
313.81
317.24
326.04
335.25
345.05
355.81
368.55
395.81
bPunto
Entropía,
kJ/(kgyK)
Liquid
Vapor
0.75
1.6989
0.7763
1.6935
0.8022
1.6889
0.8279
1.6851
0.8532
1.6819
0.8783
1.6794
0.9031
1.6774
0.9082
1.6771
0.9129
1.6768
0.9228
1.6762
0.9325
1.6757
0.9423
1.6753
0.952
1.6749
0.9617
1.6746
0.9713
1.6743
0.9809
1.6742
0.9905
1.674
1
1.6739
1.0095
1.6739
1.019
1.6739
1.0284
1.674
1.0379
1.6741
1.0472
1.6742
1.0566
1.6744
1.0659
1.6746
1.0753
1.6749
1.0846
1.6751
1.0938
1.6754
1.1031
1.6757
1.1123
1.6761
1.1215
1.6764
1.1307
1.6768
1.1398
1.6772
1.149
1.6776
1.1581
1.678
1.1672
1.6784
1.1763
1.6788
1.1854
1.6792
1.1945
1.6797
1.2036
1.6801
1.2127
1.6805
1.2217
1.6808
1.2308
1.6812
1.2399
1.6815
1.2489
1.6819
1.258
1.6822
1.2671
1.6824
1.2762
1.6826
1.2854
1.6828
1.2945
1.6829
1.3037
1.683
1.3129
1.6829
1.3222
1.6829
1.3315
1.6827
1.3408
1.6824
1.3502
1.682
1.3596
1.6815
1.3691
1.6809
1.3932
1.6786
1.4179
1.675
1.4439
1.6693
1.4719
1.6602
1.5047
1.6437
1.575
1.575
de ebullición normal
Calor Específico cp,
kJ/(kgyK)
Líquido
Vapor
1.181
0.735
1.192
0.747
1.203
0.759
1.215
0.772
1.227
0.786
1.239
0.8
1.251
0.814
1.254
0.818
1.257
0.82
1.262
0.827
1.267
0.833
1.272
0.839
1.277
0.846
1.283
0.852
1.288
0.859
1.294
0.865
1.299
0.872
1.305
0.879
1.31
0.887
1.316
0.894
1.322
0.901
1.328
0.909
1.334
0.917
1.34
0.925
1.346
0.933
1.353
0.942
1.359
0.95
1.366
0.959
1.373
0.968
1.379
0.977
1.387
0.987
1.394
0.997
1.401
1.007
1.409
1.018
1.417
1.028
1.425
1.04
1.434
1.051
1.443
1.064
1.452
1.076
1.462
1.089
1.472
1.103
1.483
1.117
1.495
1.132
1.507
1.148
1.52
1.165
1.534
1.183
1.549
1.201
1.565
1.221
1.582
1.242
1.6
1.265
1.619
1.29
1.64
1.317
1.662
1.347
1.685
1.379
1.711
1.416
1.739
1.457
1.769
1.504
1.803
1.557
1.91
1.728
2.069
1.99
2.337
2.435
2.884
3.36
4.677
6.459
¥
¥
cPunto
cp/cv
Vapor
1.119
1.119
1.119
1.12
1.121
1.122
1.124
1.125
1.125
1.126
1.127
1.128
1.129
1.131
1.132
1.134
1.135
1.137
1.139
1.141
1.143
1.145
1.147
1.15
1.152
1.155
1.158
1.161
1.164
1.168
1.172
1.176
1.18
1.184
1.189
1.194
1.2
1.206
1.212
1.219
1.226
1.234
1.242
1.251
1.261
1.272
1.284
1.296
1.31
1.326
1.343
1.362
1.383
1.406
1.433
1.463
1.498
1.538
1.667
1.866
2.209
2.927
5.309
¥
crítico
191
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos Refrigerantes
0.02096
0.02796
0.03676
0.04768
0.06107
0.07731
0.09681
0.10132
0.10562
0.11505
0.12513
0.13589
0.14736
0.15957
0.17255
0.18634
0.20097
0.21648
0.23289
0.25025
0.26858
0.28793
0.30833
0.32981
0.35242
0.37619
0.40116
0.42738
0.45487
0.48368
0.51385
0.54542
0.57843
0.61293
0.64896
0.68655
0.72576
0.76663
0.8092
0.85352
0.89964
0.9476
0.99745
1.0492
1.103
1.1588
1.2168
1.2768
1.3391
1.4036
1.4704
1.5396
1.6111
1.6852
1.7619
1.8411
1.923
2.0077
2.2319
2.4751
2.739
3.0256
3.3377
3.6362
Densidad,
kg/m3
Líquido
1373.9
1361.4
1348.7
1335.9
1322.9
1309.7
1296.3
1293.4
1290.8
1285.4
1279.9
1274.3
1268.8
1263.1
1257.5
1251.8
1246
1240.2
1234.4
1228.5
1222.5
1216.5
1210.4
1204.3
1198.1
1191.9
1185.6
1179.2
1172.8
1166.2
1159.7
1153
1146.3
1139.4
1132.5
1125.6
1118.5
1111.3
1104
1096.7
1089.2
1081.5
1073.8
1065.9
1057.8
1049.6
1041.2
1032.6
1023.8
1014.8
1005.5
996
986.2
976
965.6
954.8
943.7
932.1
901.2
866.5
826.4
776.8
707.2
489.2
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
–50
–45
–40
–35
–30
–25
–20
–18.96b
–18
–16
–14
–12
–10
–8
–6
–4
–2
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
85
90
95
100
105
109.37c
Presión,
MPa
Nombre químico o Composición
(% por masa)
Ethane
Propylene
R-125/143a (50/50)
R-125/143a/134a (44/52/4)
R-22/115 (48.8/51.2)
Chlorodifluoromethane
Ammonia
170
1270
507A
404A
502
22
717
Carbon dioxide
Ethane
Difluoromethane
R-32/125 (50/50)
R-125/143a (50/50)
R-125/143a/134a (44/52/4)
Propylene
R-22/115 (48.8/51.2)
Chlorodifluoromethane
R-32/125/134a (23/25/52)
Propane
Ammonia
2,3,3,3-tetrafluoropropene*
744
170
32
410A
507A
404A
1270
502
22
407C
290
717
1234yf
Evaporator 20°F/Condenser 86°F
Carbon dioxide
744
Evaporator –25°F/Condenser 86°F
No.
Refrigerante
36.3
48.2
55.8
57.5
57.8
66.3
69.1
70.5
72.9
93.2
94.7
293.6
421.9
16.0
22.1
26.5
27.6
28.8
28.8
146.8
195.7
113.6
169.3
156.5
183.7
172.9
189.2
189.3
206.1
211.7
273.6
279.6
675.1
1046.2
169.3
172.9
189.2
206.1
211.7
189.3
675.1
1046.2
71.3
2.99
51.8
47.1
2.86
3.13
126.6
2.74
478.5
51.1
2.92
3.51
49.4
2.9
71.9
73.5
2.94
124.1
111.2
2.95
2.8
70.1
2.3
3.19
55.7
2.48
3.00
42.1
7.14
66.8
45.1
7.46
463.9
43.5
7.34
7.81
115.7
6.57
10.61
4.76
66.0
4.6
3.86
0.42
1.61
2.78
2.80
4.25
1.58
3.92
4.05
2.72
1.80
2.85
3.59
0.43
4.44
4.60
1.73
3.03
56.8
5.35
3.52
0.43
0.084
0.399
0.296
0.287
0.429
0.381
0.46
0.476
0.316
0.229
1.238
0.726
0.087
0.307
0.48
0.521
0.54
0.416
1.314
0.711
1.15
5.91
1.89
0.942
0.935
0.619
1.58
0.649
0.616
0.651
0.902
0.421
0.203
16.7
2.32
1.48
1.61
1.52
3.63
0.878
0.457
4.44
2.47
3.05
2.62
2.62
2.63
2.50
2.54
2.50
1.77
1.62
1.20
0.73
7.19
6.95
7.06
7.13
6.98
6.28
2.66
1.61
0.809
0.754
0.787
0.795
0.772
0.813
0.79
0.842
0.848
0.815
0.797
1.314
1.342
1.569
1.589
1.722
1.817
1.833
1.637
2.805
2.779
5.835
6.254
5.987
5.93
6.105
5.799
5.975
5.598
5.564
5.78
5.924
3.588
3.514
3.007
2.967
2.739
2.595
2.573
2.88
1.681
1.698
86.0
179.8
94.8
111.0
118.0
95.8
102.8
94.3
93.5
115.8
139.4
115.8
142.3
285.6
149.8
106.3
102.1
100.6
120.3
136.2
196.3
Descarga
Presión de Presión de
Volumen Desplazamiento Consumo
Coeficiente
Relación
Efecto
Refrigerante Líquido
del Comde
de
Evapor- CondensEspecífico
de Rendide Com- Refrigerante Circulado, Circulado,
presor
Energía,
Compresor
ador,
ador,
de Succión
miento
presión Neto, Btu/lb
lb/min
gal/min
ft3/min
hp
Temp., °F
psia
psia
Gas, ft3/lb
Tabla 9.14 (I-P) Rendimiento Refrigerante Comparativo por Kilovatio de Refrigeración [2013F, Ch 29, Tbl 8
Datos Refrigerantes
09.fm Page 192 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
192
No.
54.7
193
7.9
15.9
41.1
58.7
83.9
111.7
107.9
113.6
127.6
169.3
156.5
172.9
183.7
189.2
273.6
279.6
58.7
83.9
111.7
2.57
2.44
2.11
2.01
2.06
2.04
1.92
1.96
1.92
2.09
1.84
1.9
1.98
1.85
1.89
1.89
3.29
3.44
3.37
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
59.2
66.9
140.5
127.4
64.1
69.2
54.6
55.5
64.7
484.9
130.7
73.5
74.7
49.6
75.2
112.2
119.5
60.0
65.8
3.38
2.99
1.42
1.57
3.12
2.89
3.67
3.61
3.09
0.41
1.53
2.72
2.68
4.03
2.66
1.78
1.67
3.33
3.04
0.26
0.246
0.301
0.345
0.327
0.292
0.34
0.402
0.331
0.083
0.379
0.279
0.284
0.407
0.308
0.223
0.368
0.349
0.307
9.41
5.3
4.57
3.01
1.07
0.868
0.719
0.726
0.725
3.61
1.26
0.604
0.588
0.404
0.416
0.577
4.78
1.74
1.41
31.81
15.85
6.50
4.72
3.34
2.51
2.64
2.62
2.24
1.49
1.92
1.64
1.57
1.63
1.11
1.03
7.99
5.81
4.28
0.413
0.414
0.42
0.425
0.433
0.433
0.429
0.444
0.432
0.421
0.439
0.433
0.443
0.451
0.455
0.445
0.764
0.782
0.778
*Sobrecalentamiento requerido
Fuente: Datos de NIST CYCLE _ D 4.0, cero subenfriamiento, cero sobrecalentamiento, a menos que se indique, no pérdidas de línea, 100% de eficiencia, temperaturas promedio
3.1
6.5
19.5
Trichlorotrifluoroethane*
Tetrafluoroethane
134a
56.3
113
Dichlorodifluoromethane
12
58.1
66.5
Dichlorotrifluoroethane
2,3,3,3-tetrafluoropropene*
1234yf
Butane*
R-12/152a (73.8/26.2)
500
81.0
123
Ammonia
717
85.3
90.8
600
Propane
290
29.2
Chlorodifluoromethane
22
92.8
Isobutane*
R-32/125/134a (23/25/52)
407C
102.0
600a
R-22/115 (48.8/51.2)
502
145.0
40.6
R-32/125 (50/50)
410A
1234ze(E) Trans-1,3,3,3-tetrafluoropropene*
Difluoromethane
32
Evaporator 45°F/Condenser 86°F
147.7
17.9
Isobutane*
600a
33.1
24.4
Tetrafluoroethane
11.409
11.397
11.226
11.084
10.899
10.903
11.004
10.623
10.925
11.186
10.743
10.885
10.655
10.474
10.379
10.602
6.171
6.03
6.063
86.0
86.0
86.0
86.0
86.0
90.6
91.6
86.0
94.2
137.4
90.7
104.5
102.7
91.8
103.7
116.4
86.0
86.0
94.7
Descarga
Presión de Presión de
Volumen Desplazamiento Consumo
Coeficiente
Relación
Efecto
Refrigerante Líquido
del Comde
de
Evapor- CondensEspecífico
de Rendide Com- Refrigerante Circulado, Circulado,
presor
Energía,
Compresor
ador,
ador,
de Succión
miento
presión Neto, Btu/lb
lb/min
gal/min
ft3/min
hp
Temp., °F
psia
psia
Gas, ft3/lb
1234ze(E) Trans-1,3,3,3-tetrafluoropropene*
134a
Nombre químico o Composición
(% por masa)
Refrigerante
Tabla 9.14 (I-P) Rendimiento Refrigerante Comparativo por Kilovatio de Refrigeración [2013F, Ch 29, Tbl 8 (Continuo)
09.fm Page 193 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
No.
0.152
Propileno
R-125/143a (50/50)
R-125/143a/134a (44/52/4)
R-22/115 (48.8/51.2)
Clorodifluormetano
Amoniaco
1270
507A
404A
502
22
717
2,3,3,3-Tetrafluoropropano*
Amoniaco
1234yf
Propano
Clorodifluormetano
22
717
R-22/115 (48.8/51.2)
502
290
Propileno
1270
R-32/125/134a (23/25/52)
R-125/143a/134a (44/52/4)
404A
407C
R-125/143a (50/50)
507A
Difluormetano
32
R-32/125 (50/50)
Etano
170
410A
Dióxido de Carbono
744
Evaporador –6.7°C/Condensador 30°C
0.183
Etano
0.250
0.332
0.385
0.396
0.399
0.457
0.476
0.486
0.503
0.643
0.653
2.024
2.909
0.110
0.190
0.199
0.199
1.012
Dióxido de Carbono
170
1.349
0.783
1.167
1.079
1.267
1.192
1.304
1.305
1.421
1.460
1.886
1.928
4.655
7.213
1.167
1.192
1.304
1.421
1.460
1.305
4.655
7.213
120.5
3.13
3.47
288.6
1113.0
167.1
3.19
2.8
165.9
3.51
5.98
109.5
2.99
8.30
0.90
6.03
9.13
3.40
8.42
8.70
2.86
114.9
2.9
5.85
118.8
170.9
2.94
3.87
294.4
258.6
2.95
6.13
7.72
2.92
163.1
2.3
0.93
9.54
9.89
3.72
2.74
129.5
2.48
6.44
97.8
155.3
104.9
7.46
7.14
1079.1
101.1
7.34
7.81
269.1
6.57
10.61
10.22
153.6
4.6
6.51
132.1
5.35
7.57
0.0077
0.0015
0.0072
0.0053
0.0051
0.0077
0.0068
0.0083
0.0085
0.0057
0.0041
0.0222
0.0130
0.0016
0.0055
0.0086
0.0093
0.0097
0.0075
0.0236
0.0128
0.0718
0.3689
0.1180
0.0588
0.0584
0.0386
0.0986
0.0405
0.0385
0.0406
0.0563
0.0263
0.0127
1.0425
0.1448
0.0924
0.1005
0.0949
0.2266
0.0548
0.0285
0.5954
0.3313
0.4093
0.3518
0.3520
0.3527
0.3359
0.3410
0.3349
0.2381
0.2178
0.1612
0.0977
0.9643
0.9326
0.9470
0.9565
0.9360
0.8422
0.3567
0.2160
0.1715
0.1599
0.1669
0.1686
0.1637
0.1724
0.1675
0.1785
0.1798
0.1728
0.1690
0.2786
0.2845
0.3327
0.3369
0.3651
0.3853
0.3887
0.3471
0.5947
0.5892
5.835
6.254
5.987
5.93
6.105
5.799
5.975
5.598
5.564
5.78
5.924
3.588
3.514
3.007
2.967
2.739
2.595
2.573
2.88
1.681
1.698
30.0
82.1
34.9
43.9
47.8
35.4
39.3
34.6
34.2
46.6
59.7
46.6
61.3
140.9
65.4
41.3
38.9
38.1
49.1
57.9
91.3
Desplaza- Consumo
Descarga
Presiónde
RefrigVolumen
Coeficiente
Presión de Relación Efecto de
Líquido
de
de
Evaporerante
Específico de Gas miento de
de RendiCondens- de Com- Refrigerante
Circulado,
Compresor
ador,
Circulado,
de Aspiración, Compresor, Energía,
miento
ador, MPa presión Neto, kJ/kg
L/s
L/s
kW
Temp., °C
MPa
g/s
m3/kg
744
Evaporador –31.7°C/Condensador 30°C
Nombre Químico o Composición
(% por masa)
Refrigerante
Tabla 9.14 (SI) Rendimiento Refrigerante Comparativo por Kilovatio de Refrigeración [2013F, Ch 29, Tbl 8]
Datos Refrigerantes
09.fm Page 194 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
194
Tetrafluoretano
Isobutano*
Propano
Amoniaco
R-12/152a (73.8/26.2)
717
500
Tetrafluoroethane
134a
195
Butano*
Diclorotrifluormetano
Triclorotrifluoroetano*
600
123
113
0.021
0.045
0.134
0.201
0.054
0.110
0.283
0.405
0.578
0.770
0.377
0.280
0.744
0.783
0.880
1.167
1.079
1.192
0.388
0.401
0.458
0.558
0.588
1.267
1.304
1.886
1.928
0.405
0.578
0.770
2.57
2.44
2.11
2.01
2.06
2.04
1.92
1.96
1.92
2.09
1.84
1.9
1.98
1.85
1.89
1.89
3.29
3.44
3.37
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
137.6
155.5
326.9
296.3
149.1
161.0
126.9
129.0
150.4
1127.8
303.9
171.0
173.7
115.3
175.0
261.1
278.0
139.6
153.0
7.27
6.43
3.06
3.37
6.71
6.21
7.88
7.75
6.65
0.89
3.29
5.85
5.76
8.67
5.71
3.83
3.60
7.16
6.54
0.0047
0.0044
0.0054
0.0062
0.0059
0.0052
0.0061
0.0072
0.0059
0.0015
0.0068
0.0050
0.0051
0.0073
0.0055
0.0040
0.0066
0.0063
0.0055
0.5874
0.3309
0.2853
0.1879
0.0668
0.0542
0.0449
0.0453
0.0453
0.2254
0.0787
0.0377
0.0367
0.0252
0.0260
0.0360
0.2984
0.1086
0.0880
4.2686
2.1269
0.8725
0.6332
0.4483
0.3364
0.3536
0.3514
0.3010
0.1998
0.2580
0.2205
0.2112
0.2187
0.1484
0.1381
1.0723
0.7798
0.5745
0.0876
0.0878
0.0891
0.0901
0.0918
0.0918
0.0910
0.0941
0.0916
0.0893
0.0931
0.0918
0.0939
0.0956
0.0965
0.0944
0.1620
0.1658
0.1650
11.409
11.397
11.226
11.084
10.899
10.903
11.004
10.623
10.925
11.186
10.743
10.885
10.655
10.474
10.379
10.602
6.171
6.03
6.063
30.0
30.0
30.0
30.0
30.0
32.6
33.1
30.0
34.6
58.6
32.6
40.3
39.3
33.2
39.8
46.9
30.0
30.0
34.8
DesplazaConsumo
Descarga
miento
Coeficiente
de
de
de Com
de RendiEnergía,
Compresor
presor,
miento
kW
Temp., °C
L/s
*Sobrecalentamiento requerido
Datos de NIST CYCLE_D 4.0, cero sub-enfriamiento, cero sobrecalentamiento, a menos que se indique, no pérdidas de línea, 100% de eficiencias, temperaturas promedio.
Isobutano*
600a
1234ze(E) Trans-1,3,3,3-Tetrafluoropropano*
Diclorodifluormetano
12
2,3,3,3-Tetrafluoropropano*
0.626
Clorodifluormetano
22
290
1234yf
0.640
R-32/125/134a (23/25/52)
407C
0.703
R-22/115 (48.8/51.2)
502
1.000
1.018
R-32/125 (50/50)
Difluormetano
0.123
0.168
0.228
410A
32
Evaporador 7.2°C/Condensador 30°C
600a
1234ze(E) Trans-1,3,3,3-Tetrafluoropropano*
134a
No.
Presiónde
RefrigVolumen
Presión de Relación Efecto de
Líquido
Evaporerante
Específico de Gas
Condens- de Com- Refrigerante
Circulado,
Nombre Químico o Composición
ador,
Circulado,
de Aspiración,
ador, MPa presión Neto, kJ/kg
L/s
(% por masa)
MPa
g/s
m3/kg
Refrigerante
Tabla 9.14 (SI) Rendimiento Refrigerante Comparativo por Kilovatio de Refrigeración [2013F, Ch 29, Tbl 8] (Continuo)
09.fm Page 195 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
½
5/8
¾
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
Cobre
Tipo L,
OD
Tamaño
de Línea
Temperatura de Succión Saturada, °F
–40
–20
0
20
Correspondiente p, psi/100 ft
0.97
1.41
1.96
2.62
0.09
0.15
0.24
0.36
0.16
0.28
0.44
0.68
0.28
0.47
0.76
1.15
0.43
0.73
1.17
1.78
0.88
1.49
2.37
3.61
1.54
2.59
4.13
6.28
2.44
4.10
6.53
9.92
5.07
8.52
13.53
20.51
8.97
15.07
23.88
36.16
14.34
24.02
38.05
57.56
21.31
35.73
56.53
85.39
30.09
50.32
79.66
120.39
53.85
89.97
142.32 214.82
86.74
144.47 228.50 344.70
179.88 299.39 472.46 710.75
–60
0.64
0.05
0.09
0.15
0.24
0.49
0.86
1.36
2.83
5.03
8.05
11.98
16.93
30.35
48.89
101.60
Líneas de Succión (t = 2°F)
–60
40
Correspondiente p, psi/100 ft
3.44
3.55
3.55
3.55
3.55
3.55
3.55
0.53
0.56
0.61
0.65
0.70
0.75
0.79
1.00
1.04
1.14
1.23
1.31
1.40
1.48
1.70
1.77
1.93
2.09
2.23
2.38
2.51
2.63
2.73
2.98
3.22
3.44
3.66
3.87
5.31
5.52
6.01
6.49
6.96
7.40
7.81
9.23
9.60
10.46
11.29
12.10
12.87
13.58
14.57
15.14
16.49
17.80
19.07
20.28
21.41
30.06
31.29
34.08
36.80
39.43
41.93
44.26
52.96
55.04
59.95
64.74
69.36
73.76
77.85
84.33
87.66
95.48
103.11 110.47 117.48 124.00
125.18 129.88 141.46 152.76 163.67 174.05 183.71
176.20 182.83 199.13 215.05 230.40 245.01 258.61
313.91 325.75 354.81 383.16 410.51 436.55 460.78
502.77 521.74 568.28 613.69 657.49 699.20 738.00
1037.34 1076.62 1172.66 1266.36 1356.75 1442.81 1522.89
40
Temperatura de Succión Saturada, °F
–40
–20
0
20
Líneas de Descarga (t = 1°F, p = 3.55 psi)
Velocidad t = 1°F
Caída
=
100 fpm p = 3.6
1.3
2.6
2.1
4.9
3.1
8.1
4.4
12.8
7.5
25.9
11.4
45.2
16.1
71.4
28.0
147.9
43.2
261.2
61.7
416.2
83.5
618.4
108.5
871.6
169.1
1554.2
243.1
2497.7
424.6
5159.7
Ver nota a
p = 17.4
6.09
11.39
18.87
29.81
60.17
104.41
164.68
339.46
597.42
950.09
1407.96
1982.40
3525.99
5648.67
11660.71
t = 5°F
Caida
Líneas de Líquido
Tabla 9.15 (I-P) Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 404A (Aplicaciones de una o Etapa Alta)
[2010R, Ch 1, Tbl 6]
Datos Refrigerantes
09.fm Page 196 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
196
Acero
IPS SCH
3/8
80
1/2
80
3/4
80
1
80
1 1/4 80
1 1/2 80
2
40
2 1/2 40
3
40
4
40
5
40
6
40
8
40
10
40
12
IDb
14
30
16
30
Cobre
Tipo L,
OD
Tamaño
de Línea
0.11
0.18
0.27
0.39
0.22
0.35
0.53
0.76
0.51
0.79
1.18
1.71
0.99
1.55
2.32
3.36
2.13
3.33
4.97
7.20
3.26
5.08
7.57
10.96
7.55
11.78
17.57
25.45
12.04
18.74
27.94
40.49
21.26
33.11
49.37
71.55
43.34
67.50
100.66 145.57
78.24
121.87 181.32 262.52
126.52 197.09 293.24 424.04
258.81 402.66 599.91 867.50
468.14 728.40 1083.73 1569.40
748.94 1163.62 1733.87 2507.30
968.21 1506.59 2244.98 3246.34
1395.24 2171.13 3230.27 4678.48
0.64
0.07
0.14
0.31
0.60
1.30
1.98
4.61
7.34
12.98
26.47
47.78
77.26
158.09
286.19
457.37
592.13
852.84
3.44
Correspondiente p, psi/100 ft
0.97
1.41
1.96
2.62
–60
0.04
0.08
0.18
0.35
0.75
1.14
2.65
4.23
7.48
15.30
27.58
44.58
91.40
165.52
264.36
342.81
493.87
40
Líneas de Succión (t = 2°F)
Temperatura de Succión Saturada, °F
–40
–20
0
20
0.40
0.79
1.78
3.48
7.45
11.35
26.36
41.93
74.10
150.75
272.21
439.72
898.42
1625.34
2600.54
3362.07
4845.26
3.55
0.44
0.86
1.93
3.79
8.12
12.37
28.71
45.67
80.71
164.20
296.49
478.94
978.56
1770.31
2832.50
3661.96
5277.44
0.47
0.93
2.09
4.09
8.77
13.35
31.01
49.32
87.16
177.32
320.19
517.21
1056.75
1911.78
3058.84
3954.59
5699.16
0.51
0.99
2.24
4.38
9.39
14.31
33.22
52.84
93.38
189.98
343.04
554.13
1132.18
2048.23
3277.16
4236.83
6105.92
0.54
1.06
2.38
4.66
9.99
15.21
35.33
56.19
99.31
202.03
364.80
589.28
1203.99
2178.15
3485.04
4505.59
6493.24
Correspondiente p, psi/100 ft
3.55
3.55
3.55
3.55
0.57
1.12
2.51
4.92
10.54
16.06
37.29
59.31
104.82
213.24
385.05
621.99
1270.82
2299.05
3678.47
4755.67
6853.65
3.55
Líneas de Descarga (t = 1°F, p = 3.55 psi)
Temperatura de Succión Saturada, °F
–60
–40
–20
0
20
40
1.3
2.1
3.9
6.5
11.6
16.0
30.4
43.3
66.9
115.3
181.1
261.7
453.2
714.4
1024.6
1249.2
1654.7
1.9
3.8
8.6
16.9
36.3
55.3
128.4
204.7
361.6
735.6
1328.2
2148.0
4394.4
7938.5
12,681.8
16,419.6
23,662.2
4.3
8.5
19.2
37.5
80.3
122.3
283.5
450.9
796.8
1623.0
2927.2
4728.3
9674.1
17,477.4
27,963.7
36,152.5
52,101.2
Velocidad t = 1°F t = 5°F
Caída
Caida
=
100 fpm p = 3.6 p = 17.4
Líneas de Líquido
Ver nota a
Tabla 9.15 (I-P) Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 404A (Aplicaciones de una o Etapa Alta)
[2010R, Ch 1, Tbl 6] (Continuo)
09.fm Page 197 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
197
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
34.10
52.78
0.94
1.86
3.43
5.71
11.37
20.31
31.54
67.66
120.40
195.94
401.89
715.93
22
28
35
42
54
67
79
105
130
156
206
257
785.73
484.40
273.26
128.09
82.75
46.57
23.46
14.15
7.72
3.91
2.22
1.28
455.1
0.67
1059.73 1607.24
518.54
319.22
179.89
84.12
54.30
30.50
15.36
9.26
5.04
2.55
1.45
0.83
337.2
0.43
4974.31
2805.00
1372.94
847.54
478.70
224.52
145.45
81.90
41.32
25.00
13.66
6.93
3.94
2.27
679.1
1.19
Correspondiente p, Pa/m
1189.91 1885.42 2851.68
669.47
326.58
201.19
113.08
19.12
9.61
5.78
3.14
1.59
0.90
0.53
18
0.52
240.6
0.27
0.30
165.5
0.16
–50
Líneas de Succión (t = 0.04 K/m)
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
15
12
Cobre
Tipo L,
OD,
Mm
Tamaño
de Línea
6949.80
3917.77
1921.03
1188.02
670.69
314.97
203.96
114.98
58.16
35.17
19.25
9.79
5.57
3.22
863.2
1.69
5
7641.29
7084.63
1309.04
1213.68
2116.83
738.92
685.09
4317.73
346.97
321.69
1962.62
225.07
208.67
4003.19
126.86
117.62
21.23
19.68
38.78
10.79
10.00
64.15
6.16
5.71
35.96
3.55
3.29
59.48
875.6
1.87
875.6
1.73
–50
8185.11
4625.02
2267.48
1402.20
791.51
371.66
241.08
135.89
68.72
41.54
22.74
11.56
6.59
3.81
875.6
2.00
8713.94
4923.84
2413.98
1492.80
842.65
395.67
256.66
144.67
73.16
44.23
24.21
12.30
7.02
4.05
875.6
2.13
Correspondiente p, Pa/m
9463.30
5347.26
2621.57
1621.17
915.11
429.70
278.73
157.11
79.45
48.03
26.29
13.36
7.62
4.40
875.6
2.31
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
Líneas de Descarga (t = 0.02 K/m, p = 74.90)
9923.61
5607.37
2749.09
1700.03
959.63
450.60
292.29
164.76
83.32
50.37
27.57
14.01
7.99
4.61
875.6
2.42
5
2366.6
1522.1
879.6
607.3
391.5
219.3
157.3
101.4
60.3
41.1
26.0
15.5
10.1
6.7
4.1
Velocidad
=
0.5 m/s
33 992.3
19 177.4
9382.5
5788.8
3264.9
1529.9
989.8
556.9
280.4
169.3
92.5
46.8
26.6
15.3
54 651.2
30 811.3
15 109.7
9335.2
5265.6
2473.4
1601.8
903.2
456.2
276.3
151.1
76.7
43.7
25.2
Ver nota a
t ̯=
t =
0.02 K/m
0.05 K/m
Caida
Caída
p = 875.6 p = 2189.1
8.0
13.3
Líneas de Líquido (40°C)
Tabla 9.15 (SI) Succión, Descarga y Capacidades de Línea de Líquido en kilovatios de Refrigerante 404A (Aplicaciones de Una o Etapa Alta)
[2010R, Ch 1, Tbl 6]
Datos Refrigerantes
09.fm Page 198 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
198
40
40
40
40
40
40
40
40
IDb 1044.01 1705.26 2658.28 3970.05
30
50
65
80
100
125
150
200
250
300
350
30
6830.36
80
400
4275.41
1065.97 1661.62 2485.16
80
589.35
287.77
177.97
98.60
48.38
27.33
17.16
7.38
4.83
7.57
918.60
449.08
277.71
153.84
75.47
42.72
26.81
11.55
1373.79
671.57
415.78
230.29
112.96
63.93
40.20
17.29
11.35
5.30
1947.52 3176.58 4959.92 7407.49
1351.59 2207.80 3436.53 5140.20
652.69
360.41
176.25
108.75
60.26
29.51
16.68
10.47
4.49
2.95
3.53
2.70
12 725.25
8843.83
2363.28
1155.17
714.27
396.56
194.49
110.18
69.20
29.81
19.57
9.13
4.66
2.07
40
2.25
1.80
1.20
32
1.37
1.15
0.80
80
0.70
0.51
25
1.05
679.1
80
0.61
455.1
20
0.40
337.2
Correspondiente p, Pa/m
80
0.26
240.6
80
0.31
5
–50
9671.59
6044.77
3341.30
1635.36
1012.44
560.67
275.59
155.95
98.04
42.22
27.72
12.95
6.61
2.94
1.49
875.6
6983.73
3860.32
1889.38
1169.71
647.76
318.40
180.17
113.27
48.78
32.03
14.96
7.64
3.39
1.72
875.6
7434.94
4109.73
2011.45
1245.28
689.61
338.98
191.81
120.59
51.94
34.10
15.93
8.14
3.61
1.83
875.6
Correspondiente p, Pa/m
8074.30
4463.15
2184.43
1352.37
748.91
368.13
208.31
130.96
56.40
37.03
17.30
8.84
3.92
1.99
875.6
8467.06
4680.25
2290.69
1418.15
785.34
386.03
218.44
137.33
59.14
38.83
18.14
9.27
4.12
2.09
875.6
10 431.52 11 173.92 11 895.85 12 918.83 13 547.24
6519.73
3603.84
1763.85
1091.99
604.72
297.25
168.20
105.75
45.54
29.90
13.97
7.13
3.17
1.61
875.6
5
17 677.86 18 019.86 19 435.74 20 818.96 22 164.04 24 070.04 25 240.87
12 266.49 12 503.79 13 486.26 14 446.06 15 379.40 16 701.95 17 514.38
9488.03
5930.04
3277.89
1604.32
991.91
550.03
270.35
152.98
96.18
41.42
27.20
12.68
6.48
2.88
1.46
863.2
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
15
0.16
165.5
–50
Líneas de Descarga (t = 0.02 K/m, p = 74.90)
Líneas de Succión (t = 0.04 K/m)
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
10
mm SCH
Acero
Cobre
Tipo L,
OD,
Mm
Tamaño
de Línea
5944.7
4487.7
3680.9
2566.4
1628.2
940.3
650.6
414.3
240.5
155.7
109.2
57.5
41.8
23.4
14.1
7.6
4.6
Velocidad
=
0.5 m/s
87 994.9
61 061.2
47 161.0
29 521.7
16 342.0
7988.0
4939.2
2735.7
1344.9
761.1
477.6
205.7
134.9
63.0
32.1
14.3
7.2
139 346.8
96 691.3
74 677.7
46 743.9
25 838.1
12 629.7
7819.0
4335.6
2131.2
1205.9
758.2
326.5
214.0
100.0
51.1
22.7
11.5
Ver nota a
t ̯=
t =
0.02 K/m
0.05 K/m
Caida
Caída
p = 875.6 p = 2189.1
Líneas de Líquido (40°C)
Tabla 9.15 (SI) Succión, Descarga y Capacidades de Línea de Líquido en kilovatios de Refrigerante 404A (Aplicaciones de Una o Etapa Alta)
[2010R, Ch 1, Tbl 6] (Continuo)
09.fm Page 199 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
199
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
1/2
5/8
3/4
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
Cobre
Tipo L,
OD
Tamaño
de Línea
0.67
0.05
0.09
0.16
0.25
0.50
0.88
1.39
2.91
5.15
8.24
12.27
17.34
31.09
49.99
103.91
Correspondiente p, psi/100 ft
1.01
1.46
2.02
2.71
3.6
0.09
0.15
0.24
0.37
0.55
0.17
0.28
0.45
0.69
1.02
0.28
0.48
0.77
1.17
1.74
0.44
0.74
1.18
1.81
2.68
0.90
1.51
2.40
3.66
5.41
1.57
2.63
4.18
6.35
9.41
2.48
4.17
6.61
10.04
14.84
5.17
8.65
13.70 20.76
30.66
9.14 15.27 24.19 36.62
54.04
14.61 24.40 38.55 58.29
85.90
21.75 36.22 57.15 86.47 127.52
30.66 51.13 80.55 121.93 179.33
54.88 91.25 143.93 217.14 319.89
88.20 146.87 230.77 348.36 512.29
182.97 303.62 477.80 720.09 1057.14
Temperatura de Succión Saturada, °F
–60
–40
–20
0
20
40
Líneas de Succión (t = 2°F)
3.65
0.55
1.04
1.76
2.72
5.48
9.54
15.04
31.03
54.69
86.95
129.07
181.70
323.48
518.62
1070.49
Correspondiente p, psi/100 ft
3.65
3.65
3.65
3.65
0.60
0.65
0.70
0.75
1.13
1.22
1.31
1.40
1.92
2.08
2.24
2.38
2.97
3.22
3.45
3.68
5.99
6.49
6.96
7.41
10.42
11.28
12.11
12.90
16.43
17.79
19.09
20.34
33.90
36.70
39.40
41.96
59.74
64.68
69.43
73.96
94.98 102.84 110.39 117.58
140.99 152.66 163.87 174.54
198.48 214.91 230.69 245.71
353.35 382.60 410.70 437.44
566.52 613.40 658.45 701.32
1169.35 1266.13 1359.11 1447.60
Temperatura de Succión Saturada, °F
–60
–40
–20
0
20
40
3.65
0.79
1.48
2.52
3.89
7.84
13.63
21.50
44.36
78.18
124.29
184.50
259.74
462.40
741.34
1530.21
Líneas de Descarga (t = 1°F, p = 3.65 psi)
1.3
2.0
3.0
4.2
7.2
11.0
15.6
27.1
41.8
59.6
80.6
104.8
163.3
234.8
410.1
Velocidad
=
100 fpm
t = 5°F
Caída
p = 17.8
5.96
11.13
18.45
29.14
58.74
102.09
161.04
331.97
584.28
929.27
1377.19
1935.27
3449.44
5526.55
11,383.18
t = 1°F
Caída
p = 3.65
2.5
4.7
7.9
12.5
25.2
44.0
69.5
144.0
254.3
405.2
601.0
847.0
1513.6
2427.4
5019.4
Ver Nota a
Líneas de Líquido
Tabla 9.16 (I-P) Succión, Descarga y Capacidades de Líneas de Líquido en Toneladas de Refrigerante 507A (Aplicaciones de una o Etapa Alta)
[2010R, Ch 1, Tbl 7]
Datos Refrigerantes
09.fm Page 200 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
200
Acero
IPS SCH
3/8
80
1/2
80
3/4
80
1
80
1 1/4 80
1 1/2 80
2
40
2 1/2 40
3
40
4
40
5
40
6
40
8
40
10
40
12
IDb
14
30
16
30
Cobre
Tipo L,
OD
Tamaño
de Línea
0.04
0.08
0.18
0.35
0.76
1.16
2.70
4.31
7.63
15.57
28.10
45.48
93.13
168.64
269.75
349.22
503.20
0.07
0.14
0.31
0.61
1.32
2.01
4.68
7.45
13.19
26.88
48.52
78.45
160.66
290.60
464.87
601.87
866.37
0.12
0.23
0.51
1.01
2.16
3.29
7.65
12.18
21.54
43.92
79.19
128.06
261.94
473.82
758.01
979.92
1414.32
0.18
0.35
0.80
1.57
3.36
5.12
11.89
18.93
33.45
68.12
122.99
198.91
406.93
735.12
1174.36
1520.49
2191.17
0.27
0.53
1.20
2.34
5.02
7.65
17.76
28.24
49.90
101.75
183.27
296.40
606.38
1095.44
1752.56
2269.19
3265.09
0.39
0.77
1.74
3.41
7.32
11.15
25.88
41.17
72.75
148.00
266.91
431.69
882.01
1595.65
2553.03
3300.65
4756.74
3.6
0.40
0.78
1.76
3.45
7.39
11.26
26.15
41.59
73.50
149.53
270.00
436.14
891.10
1612.10
2579.36
3334.69
4805.79
3.65
0.43
0.86
1.93
3.77
8.08
12.30
28.56
45.43
80.29
163.33
294.93
476.41
973.39
1760.97
2817.55
3642.64
5249.60
0.47
0.93
2.09
4.08
8.74
13.32
30.93
49.19
86.93
176.85
319.34
515.85
1053.96
1906.72
3050.75
3944.13
5684.09
0.51
0.99
2.24
4.38
9.39
14.30
33.20
52.80
93.32
189.84
342.79
553.73
1131.36
2046.75
3274.79
4233.77
6101.51
0.54
1.06
2.39
4.67
10.00
15.23
35.36
56.24
99.39
202.20
365.11
589.78
1205.02
2180.00
3488.00
4509.42
6498.76
0.57
1.12
2.52
4.94
10.57
16.10
37.38
59.45
105.06
213.74
385.94
623.44
1273.79
2304.41
3687.06
4766.76
6869.63
3.65
Correspondiente p, psi/100 ft
3.65
3.65
3.65
3.65
Correspondiente p, psi/100 ft
1.01
1.46
2.02
2.71
0.67
Líneas de Descarga (t = 1°F, p = 3.65 psi)
Temperatura de Succión Saturada, °F
–60
–40
–20
0
20
40
Líneas de Succión (t = 2°F)
Temperatura de Succión Saturada, °F
–60
–40
–20
0
20
40
1.2
2.1
3.8
6.3
11.2
15.5
29.4
41.9
64.6
111.4
174.9
252.8
437.7
690.0
989.6
1206.5
1598.2
Velocidad
=
100 fpm
4.2
8.3
18.7
36.6
78.4
119.4
276.7
440.6
777.9
1586.3
2857.5
4622.0
9443.9
17,086.7
27,298.3
35,292.2
50,861.5
p = 17.8
p = 3.65
1.9
3.7
8.4
16.4
35.2
53.8
124.8
198.9
351.5
714.9
1290.8
2087.5
4270.8
7715.1
12,324.9
15,957.5
22,996.2
t = 5°F
Caída
t = 1°F
Caída
Líneas de Líquido
Ver Nota a
Tabla 9.16 (I-P) Succión, Descarga y Capacidades de Líneas de Líquido en Toneladas de Refrigerante 507A (Aplicaciones de una o Etapa Alta)
[2010R, Ch 1, Tbl 7] (Continuo)
09.fm Page 201 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
201
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
12
15
18
22
28
35
42
54
67
79
105
130
156
206
257
Cobre
Tipo L,
OD,
mm
Tamaño
de Línea
173.7
0.16
0.31
0.55
0.97
1.91
3.52
5.86
11.68
20.86
32.31
69.31
123.41
200.86
412.07
733.42
–50
251.7
350.3
471.6
700.5
0.28
0.44
0.68
1.21
0.53
0.85
1.30
2.31
0.92
1.47
2.26
4.00
1.63
2.60
3.98
7.02
3.22
5.14
7.85
13.83
5.91
9.42
14.37
25.28
9.82
15.65
23.83
41.86
19.55
31.07
47.24
82.83
34.83
55.25
84.08
147.12
54.01
85.61
129.94 227.12
115.54 182.78 277.24 484.29
205.61 325.01 492.45 857.55
333.77 526.96 797.36 1389.26
683.01 1078.30 1631.18 2832.25
1216.78 1916.48 2891.11 5022.65
Correspondiente p, Pa/m
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
Líneas de Succión (t = 0.04 K/m)
–50
896.3
1.72
3.27
5.66
9.93
19.53
35.68
59.03
116.74
206.75
319.34
678.77
1202.46
1946.66
3966.22
7027.87
5
882.5
1.70
3.24
5.61
9.85
19.38
35.40
58.55
115.76
205.36
317.17
675.47
1194.03
1935.01
3937.64
6984.91
896.3
1.86
3.54
6.12
10.73
21.12
38.58
63.82
126.22
223.53
345.26
733.87
1300.07
2104.68
4288.18
7598.35
896.3
2.00
3.80
6.57
11.52
22.67
41.42
68.52
135.51
239.99
370.68
787.90
1395.78
2259.62
4603.88
8157.74
896.3
2.13
4.05
7.01
12.29
24.18
44.17
73.07
144.51
255.92
395.29
840.21
1488.45
2409.65
4909.55
8699.37
896.3
2.32
4.41
7.63
13.37
26.31
48.07
79.52
157.26
278.52
430.19
914.39
1619.87
2622.39
5343.00
9467.42
Correspondiente p, Pa/m
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
5
896.3
2.43
4.63
8.01
14.04
27.63
50.47
83.50
165.12
292.43
451.67
960.06
1700.76
2753.36
5609.84
9940.23
Líneas de Descarga(t = 0.02 K/m, p = 74.90)
Ver Nota a
t =
t =
Velocidad
0.02 K/m 0.05 K/m
=
Caída
Caída
0.5 m/s
p = 896.3 p = 2240.8
4.0
7.9
13.0
6.5
15.0
24.7
9.8
26.1
42.8
15.0
45.9
75.1
25.1
90.5
147.8
39.7
165.6
270.0
58.2
274.8
447.1
98.0
544.0
883.9
151.9
967.0
1567.7
211.9
1497.3
2420.9
378.2
3189.5
5154.4
586.7
5666.6
9129.4
849.9
9175.8
14 793.3
1470.7 18 734.6
30 099.9
2286.7 33 285.5
53 389.2
Líneas de Líquido (40°C)
Tabla 9.16 (SI) Succión, Descarga y Capacidades de Línea Líquida en Kilovatios de Refrigerante 507A (Aplicaciones de una o Etapa Alta)
[2010R, Ch 1. Tbl 7]
Datos Refrigerantes
09.fm Page 202 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
202
203
Acero
mm SCH
10 80
15 80
20 80
25 80
32 80
40 80
50 40
65 40
80 40
100 40
125 40
150 40
200 40
250 40
300 IDb
350 30
400 30
Cobre
Tipo L,
OD,
mm
0.16
0.31
0.71
1.40
3.01
4.59
10.69
17.06
30.20
61.60
111.17
179.98
368.55
666.52
1067.53
1380.23
1991.54
173.7
–50
–50
0.26
0.52
1.17
2.29
4.93
7.52
17.50
27.88
49.26
100.39
181.20
292.99
600.02
1085.29
1736.16
2247.80
3239.15
251.7
0.41
0.81
1.83
3.58
7.68
11.72
27.25
43.32
76.63
156.20
281.64
455.44
931.61
1685.18
2695.93
3485.20
5030.17
350.3
0.62
1.21
2.74
5.36
11.50
17.54
40.71
64.81
114.52
233.20
421.03
680.92
1393.04
2516.51
4020.13
5205.04
7500.91
471.6
1.06
2.09
4.71
9.23
19.76
30.09
69.87
111.37
196.37
400.40
721.18
1166.35
2386.16
4316.82
6896.51
8929.47
12 848.49
700.5
Correspondiente p, Pa/m
1.47
2.90
6.52
12.77
27.33
41.63
96.67
153.76
271.72
552.81
998.16
1612.43
3294.46
5960.02
9535.99
12 328.49
17 767.21
882.5
1.48
2.91
6.55
12.83
27.47
41.83
97.14
154.51
273.05
555.50
1003.06
1620.28
3310.49
5989.03
9582.41
12 388.50
17 853.70
896.3
1.60
3.15
7.09
13.87
29.70
45.23
105.02
167.05
295.22
600.59
1084.49
1751.80
3579.22
6475.19
10 360.26
13 394.13
19 302.97
896.3
1.72
3.38
7.61
14.89
31.88
48.56
112.76
179.35
316.95
644.81
1164.33
1880.77
3842.72
6951.89
11 122.98
14 380.20
20 724.05
896.3
1.83
3.60
8.11
15.88
34.00
51.78
120.24
191.26
338.00
687.62
1241.63
2005.64
4097.86
7413.46
11 861.49
15 334.97
22 100.02
896.3
896.3
1.99
3.92
8.83
17.28
37.00
56.35
130.86
208.14
367.84
748.33
1351.25
2182.72
4459.65
8067.98
12 908.71
16 688.86
24 051.18
Correspondiente p, Pa/m
896.3
5
2.09
4.12
9.27
18.15
38.85
59.17
137.39
218.54
386.21
785.70
1418.74
2291.73
4682.37
8470.90
13 553.39
17 522.33
25 252.33
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
5
Líneas de Descarga(t = 0.02 K/m, p = 74.90)
Líneas de Succión (t = 0.04 K/m)
Temperatura de Succión Saturada, °C
–40
–30
–20
–5
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Tamaño
de Línea
4.4
7.4
13.6
22.6
40.3
55.6
105.5
150.4
232.3
400.3
628.6
908.5
1573.2
2479.7
3556.5
4336.1
5743.9
7.1
13.9
31.4
61.6
132.0
201.0
466.6
743.5
1313.9
2675.6
4825.1
7803.5
15 964.7
28 840.0
46 140.3
59 651.3
85 963.1
11.3
22.2
49.9
97.7
209.4
319.0
740.7
1178.1
2082.0
4235.5
7638.5
12 338.1
25 241.5
45 664.6
72 953.4
94 458.7
9.3
Ver Nota a
t =
t =
Velocidad
0.02 K/m 0.05 K/m
=
Caída
Caída
0.5 m/s
p = 896.3 p = 2240.8
Líneas de Líquido (40°C)
Tabla 9.16 (SI) Succión, Descarga y Capacidades de Línea Líquida en Kilovatios de Refrigerante 507A (Aplicaciones de una o Etapa Alta)
[2010R, Ch 1. Tbl 7] (Continuo)
09.fm Page 203 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
–20
0
20
0.53
0.83
0.31
0.48
0.98
1.72
2.73
5.69
10.09
16.15
24.06
33.98
60.95
98.05
203.77 344.31
3/4
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
166.00
103.03
57.58
40.84
27.44
17.17
9.71
4.67
2.95
1.69
0.31
0.18
5/8
0.17
1.27
551.73
266.14
165.73
92.66
65.81
44.24
27.74
15.71
7.56
4.78
2.74
1.35
0.87
0.51
0.27
1.85
840.04
405.75
253.05
141.61
100.50
67.77
42.45
24.05
11.61
7.34
4.22
2.08
1.35
0.79
0.42
2.57
1229.69
594.85
370.82
208.22
147.66
99.53
62.53
35.45
17.14
10.85
6.23
3.08
2.00
1.17
0.62
3.46
Correspondiente p, psi/100 ft
–40
0.10
0.84
–60
Líneas de Succión (t = 2°F)
Temperatura de Succión Saturada, °F
1/2
Cobre
Tipo L,
OD
Tamaño
de Línea
19.39
30.63
63.20
111.20
177.12
262.44
369.45
658.32
1054.47 1099.10
2176.50 2268.62
24.28
50.19
88.43
140.83
208.65
293.70
523.21
839.82
1733.02
686.18
385.08
273.54
184.62
115.90
65.88
31.92
20.21
11.64
5.76
3.74
15.41
3.59
2.84
2.20
5.53
2.11
1.67
1.17
11.16
1.13
0.89
20
2356.89
1141.87
712.88
400.07
284.19
191.80
120.41
68.44
33.16
21.00
12.09
5.99
3.88
2.29
1.22
4.75
2437.49
1180.91
737.26
413.75
293.90
198.36
124.53
70.78
34.30
21.72
12.50
6.19
4.02
2.36
1.26
4.75
2510.41
1216.24
759.31
426.13
302.70
204.29
128.25
72.90
35.33
22.37
12.88
6.38
4.14
2.43
1.30
4.75
Correspondiente p, psi/100 ft
4.75
8.86
4.75
4.5
0
40
4.75
2567.98
1244.13
776.72
435.90
309.64
208.98
131.20
74.57
36.14
22.88
13.17
6.52
4.23
2.49
1.33
648.3
371.1
258.2
165.7
127.4
94.2
66.0
42.8
24.6
17.4
11.4
6.7
4.7
3.2
2.0
9049.5
4383.7
2729.8
1530.2
1087.5
733.0
459.7
260.7
125.9
79.7
45.8
22.6
14.3
8.6
4.6
20,561.73
9980.43
6228.40
3500.91
2491.00
1680.52
1056.39
601.13
291.48
185.04
106.59
52.92
33.53
20.24
10.81
Velocidad t = 1°F t = 5°F
Caída
Caída
=
100 fpm
p = 4.75 p = 23.3
Ver Nota a
–20
Temperatura de Succión Saturada, °F
–40
Líneas de Líquido
Líneas de Descarga (t = 1°F, p = 4.75 psi)
4.39
–60
40
Tabla 9.17 (I-P) Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 410A (Aplicaciones de Una o Etapa Alta) [2010R, Ch 1, Tbl 8]
Datos Refrigerantes
09.fm Page 204 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
204
205
2.28
5.30
89.34
182.90
331.22
529.89
80
80
80
80
80
80
40
40
40
40
40
40
40
40
IDb
30
30
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
5
6
8
10
12
14
16
988.28
685.86
55.19
30.58
14.98
8.46
1.49
0.69
0.35
0.16
SCH
3/8
–20
0
20
1628.96
2569.05
1779.99
1376.89
860.67
475.80
232.61
143.84
79.68
39.10
22.13
13.89
5.98
3.92
1.83
0.93
0.41
0.21
1.85
3852.37
2673.23
2064.68
1292.44
715.45
349.71
216.23
119.77
58.81
33.29
20.91
9.01
5.90
2.75
1.41
0.62
0.32
2.57
5575.79
3875.08
2992.85
1870.67
1035.51
506.16
312.97
173.76
85.22
48.23
30.32
13.06
8.58
4.00
2.04
0.91
0.46
3.46
Correspondiente p, psi/100 ft
1130.48
873.19
546.64
301.82
147.57
91.27
50.56
24.81
14.02
8.80
3.79
2.48
1.15
0.59
0.26
0.13
1.27
0.84
0.08
–40
7797.98
5410.92
4185.32
2615.83
1445.92
707.69
437.56
242.63
119.26
67.48
42.43
18.27
12.00
5.59
2.86
1.27
0.65
4.5
40
9771.20
6780.14
5244.38
3277.74
1811.80
886.76
548.97
304.02
149.44
84.56
53.16
22.89
15.03
7.02
3.59
1.59
0.81
4.75
–60
–20
0
10,184.73
7067.08
5466.33
3416.46
10,581.02
7342.06
5679.03
3549.40
1961.96
960.25
594.46
329.21
161.82
91.57
57.57
24.79
16.28
7.60
3.88
1.73
0.88
4.75
10,942.85
7593.13
5873.23
3670.77
2029.05
993.09
614.79
340.47
167.36
94.70
59.54
25.64
16.83
7.86
4.02
1.78
0.91
4.75
20
11,270.23
7820.29
6048.94
3780.59
2089.76
1022.80
633.19
350.66
172.37
97.53
61.32
26.41
17.34
8.10
4.14
1.84
0.93
4.75
Correspondiente p, psi/100 ft
1888.48
924.29
572.20
316.88
155.76
88.14
55.41
23.86
15.67
7.32
3.74
1.66
0.84
4.75
–40
Temperatura de Succión Saturada, °F
–60
IPS
Acero
Cobre
Tipo L,
OD
Líneas de Descarga (t = 1°F, p = 4.75 psi)
Líneas de Succión (t = 2°F)
Temperatura de Succión Saturada, °F
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Tamaño
de Línea
11,528.68
7999.63
6187.65
3867.29
2137.68
1046.26
647.71
358.70
176.32
99.77
62.73
27.01
17.74
8.28
4.23
1.88
0.95
4.75
40
2526.4
1907.2
1564.3
1090.7
692.0
399.6
276.5
176.1
102.2
66.2
46.4
24.4
17.7
10.0
6.0
3.2
1.9
41,220.5
28,647.5
22,125.4
13,829.2
7655.3
3741.9
2313.7
1284.6
630.0
356.5
224.2
96.6
63.3
29.5
15.1
6.7
3.4
91,435.1
63,445.8
49,074.9
30,716.4
16,977.6
8308.9
5137.0
2851.7
1398.4
793.0
498.0
214.7
140.9
65.8
33.6
15.0
7.6
Velocidad t ̯= 1°F t = 5°F
Caída
Caída
=
100 fpm
p = 4.75 p = 23.3
Ver Nota a
Líneas de Líquido
Tabla 9.17 (I-P) Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 410A (Aplicaciones de Una o Etapa Alta) [2010R, Ch 1, Tbl 8]
09.fm Page 205 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
–20
–5
2305.4
3584.6
1427.49 2276.75 3480.75 5095.42 8506.22 11 575.35 14 185.59 14 729.76 15 249.20 15 719.17 16 337.55 16 659.10
257
8302.53
9390.02
4079.57
7995.81
800.39 1280.57 1956.28 2868.65 4796.70
3928.86
390.21 625.92 957.07 1405.29 2352.81
206
2517.13
2424.14
156
1423.81
1371.21
240.18 384.82 590.29
668.47
643.78
130
433.60
417.58
134.69 216.27 331.96
244.38
235.35
105
123.57
119.01
62.89
74.82
72.05
79
40.95
39.44
40.48
20.81
20.04
22.70
56.35
100.35
101.10 155.22
65.21
36.61
28.38
866.21
488.64
229.02
147.94
83.26
42.00
1452.34
820.20
384.65
249.16
140.29
70.89
42.82
6532.82
3206.57
1978.69
1119.32
525.59
340.33
191.84
97.02
58.75
32.11
16.32
8595.32
4223.44
2605.89
1474.02
692.05
448.89
253.00
127.93
77.46
42.39
21.54
8860.22
4353.60
2686.20
1519.45
713.37
462.73
260.80
131.87
79.84
43.70
22.20
12.67
9208.77
4524.87
2791.88
1579.22
741.44
480.93
271.06
137.06
82.98
45.42
23.08
13.16
4613.92
2846.83
1610.30
756.03
490.40
276.39
139.76
84.62
46.31
23.53
13.42
6.2
1332.3
919.8
592.9
332.2
238.2
153.7
91.3
62.2
39.3
23.5
15.4
10.1
67
18.39
25.33
23.43
11.89
12.29
7.75
4.07
54
11.87
11.43
7.60
11.39
17.11
7.00
13.82
9.30
7.31
42
11.07
9.32
4.72
6.76
7.09
6.84
6.85
6.60
1172.1
35
6.03
3.04
3.98
5.37
4.00
1172.1
3.72
2.68
3.90
3.84
1172.1
1.87
1.72
2.29
3.73
1172.1
28
3.60
3.47
22
1172.1
1172.1
59 763.6
33 708.0
16 502.3
10 188.7
5744.4
2695.2
1746.4
982.0
495.7
299.6
163.7
83.0
47.3
27.2
14.3
95 683.0
53 996.3
26 500.6
16 386.3
9249.0
4350.8
2816.7
1590.3
804.1
486.0
266.4
135.3
77.2
44.6
23.5
t =
t =
Velocidad 0.02 K/m 0.05 K/m
=
Caída
Caída
0.5 m/s
p = 1179 p = 2935.8
1.06
1.54
2.83
1137.6
5
18
0.99
2.05
894.2
–5
0.61
1.20
599.1
Correspondiente p, Pa/m
–20
Ver Nota a
–30
Temperatura de Succión Saturada, °C
–40
–50
15
0.80
443.3
5
Líneas de Líquido (40°C)
Líneas de Descarga (t = 0.02 K/m, p = 74.90)
0.32
0.52
317.2
218.6
–30
Correspondiente p, Pa/m
–40
–50
Temperatura de Succión Satirada, °C
Líneas de Succión (t = 0.04 K/m)
12
Cobre
Tipo L,
OD,
Mm
Tamaño
de Línea
Tabla 9.17 (SI) Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante 410A (Aplicaciones de Una o Etapa Alta) [2010R, Ch 1, Tbl 8]
Datos Refrigerantes
09.fm Page 206 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
206
80
80
40
40
40
40
40
40
40
40
IDb 2075.09
30
32
40
50
65
80
100
125
150
200
250
300
350
30
3255.45
80
25
400
2035.01
1297.30
80
20
3870.92
2686.45
717.23
350.32
216.38
119.78
58.79
33.22
20.81
8.94
5.86
2.72
1.39
6064.31
4214.83
1125.10
549.37
339.76
188.24
92.36
52.18
32.75
14.09
9.24
4.30
2.19
0.97
80
0.61
80
15
0.49
317.2
218.6
0.31
–40
–20
9173.88
7085.49
4435.35
2451.89
1200.12
742.06
411.01
201.84
114.11
71.75
30.91
20.26
9.45
4.82
2.14
1.08
599.1
9135.88 13 220.36
6329.87
4896.39
3060.66
1692.00
827.18
511.52
283.69
139.17
78.69
49.39
21.28
13.95
6.50
3.32
1.47
0.74
443.3
–5
21 760.24
15 122.98
11 679.95
7310.97
4041.21
1975.34
1221.40
678.11
332.58
188.61
118.34
50.97
33.47
15.63
7.98
3.54
1.80
894.2
Correspondiente p, Pa/m
–30
5
–50
29 442.67
20 429.97
15 802.42
9876.55
5459.36
2672.01
1654.16
916.08
450.29
254.80
160.19
68.99
45.30
21.16
10.81
4.80
2.44
1137.6
35 992.70
24 974.96
19 317.94
12 073.76
6673.89
3266.45
2022.16
1121.21
550.47
311.49
195.83
84.33
55.37
25.86
13.21
5.87
2.98
1172.1
37 373.41
25 933.02
20 059.00
12 536.92
6929.91
3391.75
2099.73
1164.22
571.59
323.43
203.34
87.57
57.50
26.85
13.72
6.09
3.10
1172.1
–40
–20
38 691.36
26 847.53
20 766.37
12 979.03
7174.29
3511.36
2173.77
1205.28
591.74
334.84
210.51
90.66
59.53
27.80
14.20
6.31
3.21
1172.1
39 883.80
27 674.95
21 406.37
13 379.03
7395.39
3619.58
2240.77
1242.42
609.98
345.16
217.00
93.45
61.36
28.66
14.64
6.50
3.31
1172.1
Correspondiente p, Pa/m
–30
41 452.79
28 763.66
22 248.47
13 905.35
7686.32
3761.97
2328.92
1291.30
633.98
358.74
225.54
97.13
63.77
29.79
15.22
6.76
3.44
1172.1
–5
Temperatura de Succión Saturada, °C
–50
Líneas de Descarga (t = 0.02 K/m, p = 74.90)
Líneas de Succión (t = 0.04 K/m)
Temperatura de Succión Satirada, °C
10
mm SCH
Acero
Cobre
Tipo L,
OD,
Mm
Tamaño de
Línea
42 268.67
29 329.79
22 686.37
14 179.04
7837.60
3836.01
2374.75
1316.72
646.46
365.80
229.98
99.04
65.03
30.37
15.52
6.89
3.50
1172.1
5
9004.3
6797.4
5575.3
3887.3
2466.2
1424.2
985.4
627.6
364.2
235.8
165.4
87.1
63.2
35.5
21.3
11.5
6.9
Velocidad
=
0.5 m/s
153 611.4
106 757.2
82 451.9
51 535.6
28 528.0
13 944.5
8622.2
4787.0
2347.8
1328.6
835.4
359.8
235.9
110.2
56.2
25.0
242 779.1
168 461.9
130 304.0
81 440.3
45 016.9
22 032.9
13 639.9
7562.8
3713.1
2101.0
1320.9
568.9
174.5
89.1
39.6
20.1
p = 2935.8
p = 1179
12.7
t =
0.05 K/m
Caída
t =
0.02 K/m
Caída
Ver Nota a
Líneas de Líquido (40°C)
Tabla 9.17 (SI) Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante 410A (Aplicaciones de Una o Etapa Alta) [2010R, Ch 1, Tbl 8]
(Continuo)
09.fm Page 207 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
207
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
0.04
0.08
0.14
0.21
0.44
0.77
1.23
2.56
4.55
7.30
10.90
15.42
27.70
44.70
92.98
5/8
3/4
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
0.435
–60
1/2
CobreTipo
L,
OD
Tamaño de
Línea
170.14
81.91
50.85
28.37
20.08
13.47
8.42
4.74
2.27
1.43
0.82
0.40
0.26
0.15
0.08
0.7
–20
0
290.93
140.04
86.97
48.62
34.44
23.15
14.49
8.18
3.93
2.48
1.42
0.70
0.45
0.26
0.14
1.06
471.55
227.86
141.60
79.21
56.15
37.76
23.64
13.37
6.44
4.07
2.33
1.15
0.74
0.43
0.23
1.55
20
725.11
350.42
218.05
122.10
86.64
58.34
36.62
20.72
10.00
6.33
3.63
1.79
1.16
0.68
0.36
2.16
Correspondiente p, psi/100 ft
–40
Temperatura de Succión Saturada, °F
Líneas de Succión (t = 2°F)
1.33
2.26
3.48
7.05
12.25
19.33
39.99
70.56
112.34
166.39
234.63
417.91
670.58
1383.29 1458.72
1.02
1.74
2.68
5.42
9.45
14.93
30.90
54.50
86.88
128.89
181.34
323.50
519.62
1072.54
3.3
3.3
0.71
0.54
707.15
440.69
247.42
175.47
118.47
74.41
42.17
20.39
12.92
7.43
3.67
2.38
1.40
0.75
0
20
1534.15
743.71
463.48
260.22
184.54
124.59
78.25
44.35
21.44
13.59
7.82
3.86
2.50
1.47
0.78
3.3
1606.88
778.97
485.46
272.56
193.29
130.50
81.96
46.45
22.46
14.23
8.19
4.05
2.62
1.54
0.82
3.3
1674.23
811.62
505.80
283.98
201.39
135.97
85.40
48.40
23.40
14.83
8.53
4.22
2.73
1.61
0.86
3.3
Correspondiente p, psi/100 ft
–20
1738.88
842.96
525.33
294.95
209.17
141.22
88.70
50.27
24.30
15.40
8.86
4.38
2.84
1.67
0.89
3.3
40
672.4
385.0
267.8
171.8
132.2
97.7
68.5
44.4
25.5
18.0
11.8
6.9
4.9
3.4
2.1
Velocidad
=
100 fpm
7599.4
3676.9
2288.8
1281.5
907.9
611.3
383.7
217.1
104.7
66.2
37.9
18.7
11.8
7.1
17,220.64
8344.10
5209.13
2923.40
2076.59
1401.50
879.85
499.23
241.93
153.45
88.21
43.73
27.66
16.68
8.90
p = 16.9
p = 3.5
3.8
t = 5°F
Caída
t ̯= 1°F
Caída
Ver Nota a
–40
Temperatura de Succión Saturada °F
2.92
–60
40
Líneas de Liquido
Líneas de Descarga (t = 1°F, p = 3.3 psi)
Tabla 9.18 (I-P) Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 407C (Aplicaciones de Una o Alta Etapa) [2010R, Ch 1, Tbl 9]
Datos Refrigerantes
09.fm Page 208 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
208
209
Acero
IPS SCH
3/8 80
1/2 80
3/4 80
1
80
1 1/4 80
1 1/2 80
2
40
2 1/2 40
3
40
4
40
5
40
6
40
8
40
10 40
12 IDb
14 30
16 30
Cobre Tipo
L,
OD
0.04
0.07
0.16
0.32
0.69
1.06
2.49
3.97
7.04
14.38
26.00
42.13
86.32
156.54
250.23
324.38
468.29
0.435
–60
0.07
0.13
0.30
0.58
1.25
1.91
4.46
7.11
12.59
25.70
46.36
75.15
153.84
278.57
445.65
576.93
831.27
0.7
0
1.55
0.11
0.18
0.22
0.35
0.50
0.80
0.98
1.57
2.10
3.37
3.21
5.13
7.47
11.93
11.90
19.01
21.05
33.59
42.97
68.47
77.55
123.61
125.49 199.88
256.66 408.86
464.86 739.58
742.54 1183.19
961.33 1529.58
1385.24 2204.17
1.06
2.16
20
0.27
0.54
1.22
2.38
5.12
7.79
18.13
28.83
50.94
103.84
187.25
302.82
619.47
1120.60
1790.17
2317.81
3340.17
Correspondiente p, psi/100 ft
–20
40
–60
0.40
0.79
1.79
3.50
7.50
11.44
26.57
42.25
74.66
152.24
274.21
443.47
907.26
1638.95
2622.17
3395.13
4885.19
2.92
0.52
1.02
2.29
4.50
9.63
14.66
34.04
54.25
95.76
195.04
351.31
568.16
1162.36
2102.83
3359.45
4349.77
6258.81
3.3
–20
0
0.57
1.13
2.54
4.99
10.68
16.26
37.75
60.16
106.21
216.31
389.62
630.12
1289.12
2332.15
3725.82
4824.14
6941.37
3.3
0.60
1.18
2.66
5.22
11.18
17.03
39.54
63.02
111.24
226.57
408.09
659.99
1350.24
2442.72
3902.46
5052.85
7270.46
3.3
3.3
20
0.63
1.23
2.78
5.44
11.65
17.74
41.20
65.66
115.90
236.06
425.19
687.65
1406.83
2545.10
4066.02
5264.62
7575.17
Correspondiente p, psi/100 ft
0.55
1.07
2.42
4.74
10.15
15.46
35.89
57.21
100.99
205.68
370.46
599.14
1225.74
2217.49
3542.64
4586.95
6600.09
3.3
–40
Temperatura de Succión Saturada °F
–40
Líneas de Descarga (t= 1°F, p = 3.3 psi)
Líneas de Succión (t = 2°F)
Temperatura de Succión Saturada, °F
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Tamaño de
Línea
0.65
1.28
2.88
5.65
12.10
18.43
42.79
68.19
120.38
245.18
441.61
714.21
1461.15
2643.38
4223.03
5467.92
7867.69
3.3
40
2.0
3.4
6.2
10.3
18.4
25.4
48.1
68.6
106.0
182.6
286.8
414.5
717.7
1131.3
1622.5
1978.2
2620.4
Velocidad =
100 fpm
6.4
12.6
28.4
55.6
118.9
181.1
420.6
669.0
1182.3
2405.3
4343.2
7015.7
14,334.3
25,932.3
41,491.5
53,641.7
77,305.8
p = 16.9
p = 3.5
2.9
5.7
12.8
25.1
53.7
82.0
190.3
303.2
535.7
1092.0
1969.0
3184.3
6514.5
11,784.6
18,826.0
24,374.8
35,126.4
t = 5°F
Caída
t ̯= 1°F
Caída
Ver Nota a
Líneas de Liquido
Tabla 9.18 (I-P) Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 407C (Aplicaciones de Una o Alta Etapa) [2010R, Ch 1, Tbl 9]
(Continuo)
09.fm Page 209 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
–20
–5
34.83
54.01
0.97
1.91
3.52
5.86
11.68
20.86
32.31
69.31
123.41
200.86
412.07
733.42 1216.78 1916.48 2891.11 5022.65
28
35
42
54
67
79
105
130
156
206
257
526.96
325.01
182.78
85.61
55.25
31.07
15.65
9.42
5.14
2.60
1.47
797.36
492.45
277.24
129.94
84.08
47.24
23.83
14.37
7.85
3.98
2.26
1389.26
857.55
484.29
227.12
147.12
82.83
41.86
25.28
13.83
7.02
4.00
683.01 1078.30 1631.18 2832.25
333.77
205.61
115.54
19.55
9.82
5.91
3.22
1.63
0.92
2.31
0.55
1.30
22
0.85
18
0.53
1.21
700.5
0.31
0.68
471.6
15
0.44
350.3
0.16
0.28
251.7
173.7
–30
Correspondiente p, Pa/m
–40
–50
Temperatura de Succión Saturada, °C
Líneas de Succión (t = 0.04 K/m)
12
Cobre Tipo
L,
OD,
mm
Tamaño de
Línea
6984.91
3937.64
1935.01
1194.03
675.47
317.17
205.36
115.76
58.55
35.40
19.38
9.85
5.61
3.24
1.70
882.5
5
345.26
733.87
1300.07
319.34
678.77
1202.46
7598.35
223.53
206.75
7027.87
126.22
116.74
2104.68
63.82
59.03
4288.18
38.58
35.68
1946.66
21.12
19.53
3966.22
6.12
10.73
3.54
3.27
9.93
1.86
1.72
5.66
896.3
896.3
8157.74
4603.88
2259.62
1395.78
787.90
370.68
239.99
135.51
68.52
41.42
22.67
11.52
6.57
3.80
2.00
896.3
8699.37
4909.55
2409.65
1488.45
840.21
395.29
255.92
144.51
73.07
44.17
24.18
12.29
7.01
4.05
2.13
896.3
Correspondiente p, Pa/m
–20
9467.42
5343.00
2622.39
1619.87
914.39
430.19
278.52
157.26
79.52
48.07
26.31
13.37
7.63
4.41
2.32
896.3
–5
9940.23
5609.84
2753.36
1700.76
960.06
451.67
292.43
165.12
83.50
50.47
27.63
14.04
8.01
4.63
2.43
896.3
2286.7
1470.7
849.9
586.7
378.2
211.9
151.9
98.0
58.2
39.7
25.1
15.0
9.8
6.5
4.0
33 285.5
18 734.6
9175.8
5666.6
3189.5
1497.3
967.0
544.0
274.8
165.6
90.5
45.9
26.1
15.0
7.9
53 389.2
30 099.9
14 793.3
9129.4
5154.4
2420.9
1567.7
883.9
447.1
270.0
147.8
75.1
42.8
24.7
13.0
Velocidad t = 0.02 K/m t = 0.05 K/m
Caída
Caída
=
0.5 m/s
p = 896.3
p = 2240.8
Ver Nota a
–30
Temperatura de Succión Saturada, °C
–40
–50
Líneas de Líquido (40°C)
Líneas de Descarga (t = 0.02 K/m, p = 74.90)
5
Tabla 9.18 (SI) Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante 407C (Aplicaciones de Una o Alta Etapa) [2010R, Ch 1, Tbl 9]
Datos Refrigerantes
09.fm Page 210 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
210
80
40
40
40
40
40
40
40
40
IDb 1067.53 1736.16
30
40
50
65
80
100
125
150
200
250
300
350
30
2695.93 4020.13
80
32
400
1685.18 2516.51
1085.29
80
25
600.02
292.99
181.20
100.39
49.26
27.88
17.50
7.52
4.93
2.29
1.17
1991.54 3239.15
1380.23 2247.80
666.52
368.55
179.98
111.17
61.60
30.20
17.06
10.69
4.59
3.01
1.40
0.71
1393.04
680.92
421.03
233.20
114.52
64.81
40.71
17.54
11.50
5.36
2.74
–5
5
8929.47
6896.51
4316.82
2386.16
1166.35
721.18
400.40
196.37
111.37
69.87
30.09
19.76
9.23
4.71
2.09
1.06
700.5
12 328.49
9535.99
5960.02
3294.46
1612.43
998.16
552.81
271.72
153.76
96.67
41.63
27.33
12.77
6.52
2.90
1.47
882.5
5030.17 7500.91 12 848.49 17 767.21
3485.20 5205.04
931.61
455.44
281.64
156.20
76.63
43.32
27.25
11.72
7.68
3.58
1.83
1.21
80
0.81
20
0.52
80
0.31
80
0.62
471.6
15
0.41
350.3
SCH
0.26
–20
10
0.16
251.7
173.7
–30
Correspondiente p, Pa/m
–40
–50
17 853.70
12 388.50
9582.41
5989.03
3310.49
1620.28
1003.06
555.50
273.05
154.51
97.14
41.83
27.47
12.83
6.55
2.91
1.48
896.3
19 302.97
13 394.13
10 360.26
6475.19
3579.22
1751.80
1084.49
600.59
295.22
167.05
105.02
45.23
29.70
13.87
7.09
3.15
1.60
896.3
–40
–20
20 724.05
14 380.20
11 122.98
6951.89
3842.72
1880.77
1164.33
644.81
316.95
179.35
112.76
48.56
31.88
14.89
7.61
3.38
1.72
896.3
22 100.02
15 334.97
11 861.49
7413.46
4097.86
2005.64
1241.63
687.62
338.00
191.26
120.24
51.78
34.00
15.88
8.11
3.60
1.83
896.3
Correspondiente p, Pa/m
–30
24 051.18
16 688.86
12 908.71
8067.98
4459.65
2182.72
1351.25
748.33
367.84
208.14
130.86
56.35
37.00
17.28
8.83
3.92
1.99
896.3
–5
Temperatura de Succión Saturada, °C
–50
Líneas de Descarga (t = 0.02 K/m, p = 74.90)
Líneas de Succión (t = 0.04 K/m)
Temperatura de Succión Saturada, °C
mm
Acero
Cobre Tipo
L,
OD,
mm
Tamaño de
Línea
25 252.33
17 522.33
13 553.39
8470.90
4682.37
2291.73
1418.74
785.70
386.21
218.54
137.39
59.17
38.85
18.15
9.27
4.12
2.09
896.3
5
5743.9
4336.1
3556.5
2479.7
1573.2
908.5
628.6
400.3
232.3
150.4
105.5
55.6
40.3
22.6
13.6
7.4
4.4
85 963.1
59 651.3
46 140.3
28 840.0
15 964.7
7803.5
4825.1
2675.6
1313.9
743.5
466.6
201.0
132.0
61.6
31.4
13.9
7.1
136 129.3
94 458.7
72 953.4
45 664.6
25 241.5
12 338.1
7638.5
4235.5
2082.0
1178.1
740.7
319.0
209.4
97.7
49.9
22.2
11.3
Velocidad t = 0.02 K/m t = 0.05 K/m
Caída
Caída
=
0.5 m/s
p = 896.3
p = 2240.8
Ver Nota a
Líneas de Líquido (40°C)
Tabla 9.18 (SI) Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante 407C (Aplicaciones de Una o Alta Etapa) [2010R, Ch 1, Tbl 9]
(Continuo)
09.fm Page 211 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
211
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
½
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
Acero
IPS
SCH
1/2
40
3/4
40
1
40
1 1/4
40
1 1/2
40
2
40
Cobre
Tipo L,
OD
Tamaño de Línea
Tabla 9.19 (I-P)
—
0.50
0.95
2.0
3.0
5.7
0.79
—
—
0.52
1.1
1.9
3.0
6.2
10.9
17.5
26.0
36.8
–40
0.38
0.8
1.5
3.2
4.7
9.1
0.58
1.2
2.3
4.8
7.2
13.9
0.85
1.8
3.4
7.0
10.5
20.2
Líneas de Succión (t = 2°F)
Temperatura de Succión Saturada, °F
–20
0
20
Correspondiente p, psi/100 ft
1.15
1.6
2.22
—
—
0.40
0.32
0.51
0.76
0.86
1.3
2.0
1.7
2.7
4.0
3.1
4.7
7.0
4.8
7.5
11.1
10.0
15.6
23.1
17.8
27.5
40.8
28.4
44.0
65.0
42.3
65.4
96.6
59.6
92.2
136.3
1.2
2.5
4.8
9.9
14.8
28.5
2.91
0.6
1.1
2.9
5.8
10.1
16.0
33.1
58.3
92.9
137.8
194.3
40
1.5
3.3
6.1
12.6
19.0
36.6
1.7
3.7
6.9
14.3
21.5
41.4
Líneas de Descarga
(t = 1°F, p = 3.05 psi)
Temperatura de Succión
Saturada, °F
–40
40
0.75
0.85
1.4
1.6
3.7
4.2
7.5
8.5
13.1
14.8
20.7
23.4
42.8
48.5
75.4
85.4
120.2
136.2
178.4
202.1
251.1
284.4
Cobre
Tipo L,
OD
1/2
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
Acero
IPS
SCH
1/2
80
3/4
80
1
80
1 1/4
80
1 1/2
80
2
40
Tamaño de Línea
3.8
6.9
11.5
20.6
28.3
53.8
2.3
3.7
7.8
13.2
20.2
28.5
49.6
76.5
109.2
147.8
192.1
Vel. =
100 fpm
5.7
12.8
25.2
54.1
82.6
192.0
p = 3.05
3.6
6.7
18.2
37.0
64.7
102.5
213.0
376.9
601.5
895.7
1263.2
t = 1°F
Líneas de Líquido
Ver Notas a y b
Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 22 (Aplicaciones de Una o Alta Etapa)
[2010R, Ch 1, Tbl 3]
Datos Refrigerantes
09.fm Page 212 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
212
9.2
16.2
33.1
0.79
–40
14.6
25.7
52.5
22.1
39.0
79.5
32.2
56.8
115.9
Líneas de Succión (t = 2°F)
Temperatura de Succión Saturada, °F
–20
0
20
Correspondiente p, psi/100 ft
1.15
1.6
2.22
Tamaño mostrado es recomendado donde cualquier gas generado en el receptor debe devolver hasta la
línea de condensado al condensador sin restringir el flujo de condensado. Los condensadores de agua
enfriada, donde la temperatura ambiente del receptor puede ser más alta que la temperatura de condensación del refrigerante, cae dentro de esta categoría.
 Actual L e  Capacidad Actual  1.8
 -----------------------  -----------------------------------------------
 Tabla L e  Capacidad de Tabla
Datos Refrigerantes
213
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
a
t = Tabla  t
2. Capacidad de Línea de otras temperaturas de saturación t y longitudes equivalentes Le
 Tabla L e Actual t 0.55
Capacidad de Línea = Capacidad de tabla  -----------------------  -----------------------
 Actual L e Tabla t 
3. Temperatura de saturación t para otras capacidades y longitudes equivalentes Le
45.4
80.1
163.2
2.91
40
65.9
116.4
237.3
Cobre
Tipo L,
OD
Acero
IPS
SCH
2 1/2
40
3
40
4
40
Tamaño de Línea
76.7
118.5
204.2
Vel. =
100 fpm
305.8
540.3
1101.2
p = 3.05
t = 1°F
Líneas de Líquido
Ver Notas a y b
b
1.11
1.07
1.03
0.97
0.90
0.86
0.80
Línea de Succión
0.79
0.88
0.95
1.04
1.10
1.18
1.26
Línea de Descarga
La línea de caída de presión p es conservativa; si el sub-enfriamiento es sustancial o la línea es
corta, una línea de menor tamaño puede ser utilizada. Aplicaciones con sub enfriamiento muy
pequeño o líneas muy largas pueden requerir una línea más grande.
Temperatura de
Condensación, °F
80
90
100
110
120
130
140
4. Valores basados en 105°F temperatura de condensación. Multiplicar capacidades de la tabla
por los siguientes factores para otras temperaturas de condensación.
58.1
102.8
209.5
Líneas de Descarga
(t = 1°F, p = 3.05 psi)
Temperatura de Succión
Saturada, °F
–40
40
Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 22 (Aplicaciones de Una o Alta Etapa)
[2010R, Ch 1, Tbl 3] (Continuo)
Notass:
1. Las capacidades de la Tabla están en toneladas de refrigeración.
p = caída de presión de línea de presión, psi por 100 pie of longitud de línea equivalente
t = Cambio correspondiente en temperatura de saturación, °F por 100 pie
Acero
IPS
SCH
2 1/2
40
3
40
4
40
Cobre Tipo L,
OD
Tamaño de Línea
Tabla 9.19 (I-P)
09.fm Page 213 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
0.32
0.61
1.06
1.88
3.73
6.87
11.44
22.81
40.81
63.34
136.0
0.47
0.88
1.86
3.52
7.31
10.98
79
105
10
15
20
25
32
40
196
–40
Líneas de Descarga
(t = 0.02 K/m, p = 74.90)
0.72
1.35
2.84
5.37
11.12
16.71
98.13
210.3
1.06
1.98
4.17
7.87
16.27
24.45
145.9
312.2
1.78
3.30
6.95
13.11
27.11
40.67
247.2
527.8
337.9
721.9
LINEA DE ACERO
2.42
4.48
9.44
17.82
36.79
55.21
3.04
5.62
11.80
22.29
46.04
68.96
431.3
919.7
3.23
5.97
12.55
23.70
48.94
73.31
458.5
977.6
3.44
6.36
13.36
25.24
52.11
78.07
488.2
1041.0
5
Temperatura de Succión Saturada, °C
Correspondiente p, Pa/m
277
378
572
731
–40
–20
5
LINEA DE COBRE TIPO L
0.50
0.75
1.28
1.76
2.30
2.44
2.60
0.95
1.43
2.45
3.37
4.37
4.65
4.95
1.66
2.49
4.26
5.85
7.59
8.06
8.59
2.93
4.39
7.51
10.31
13.32
14.15
15.07
5.82
8.71
14.83
20.34
26.24
27.89
29.70
10.70
15.99
27.22
37.31
48.03
51.05
54.37
17.80
26.56
45.17
61.84
79.50
84.52
90.00
35.49
52.81
89.69
122.7
157.3
167.2
178.1
63.34
94.08
159.5
218.3
279.4
297.0
316.3
Temperatura de Succión Saturada, °C
–30
–20
–5
Líneas de Succión (t = 0.04 K/m)
10.66
16.98
29.79
48.19
83.56
113.7
15.96
29.62
62.55
118.2
244.4
366.6
2190.9
4697.0
11.24
21.54
37.49
66.18
131.0
240.7
399.3
794.2
1415.0
7.08
11.49
17.41
26.66
44.57
70.52
103.4
174.1
269.9
376.5
672.0
t =
0.02 K/m
p = 749
Velocidad =
0.5 m/s
Líneas de Líquido
Ver Nota a
Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante 22 (Aplicaciones de Una o Alta Etapa)
[2010R, Ch 1, Tbl 3]
12
15
18
22
28
35
42
54
67
Línea
Nominal
OD,
mm
Tabla 9.19 (SI)
Datos Refrigerantes
09.fm Page 214 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
214
32.23
51.44
90.95
185.6
47.19
75.19
132.8
270.7
215
 Actual L e  Capacidad Actual  1.8
 -----------------------  -----------------------------------------------
 Tabla L e  Capacidad de Tabla
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
5
es recomendado donde cualquier gas generado en el receptor debe devolver hasta la línea de condensado al condensador sin restringir el flujo de condensado. Los condensadores de agua enfriada, donde la temperatura ambiente del receptor puede ser más alta que la temperatura de condensación del refrigerante, cae
dentro de esta categoría.
aTamaño
t = Tabla t
3. Temperatura de saturación t para otras capacidades y longitudes equivalentes Le
2. Capacidad de línea para otras temperaturas de saturación t y longitudes equivalentes Le
 Tabla L e Actual t 0.55
Capacidad de línea = Capacidad de Tabla  -----------------------  -----------------------
 Actual L e Tabla t 
t = cambio correspondiente en temperatura de saturación, K/m
p = caída de presión por unidad equivalente a longitud de la línea, Pa/m
78.51
124.8
220.8
450.1
196
21.21
33.84
59.88
122.3
Correspondiente p, Pa/m
277
378
572
–40
Líneas de Descarga
(t = 0.02 K/m, p = 74.90)
141.3
224.7
397.1
809.7
–20
150.5
239.3
422.9
862.2
5
187.5
267.3
412.7
711.2
Velocidad =
0.5 m/s
707.5
1127.3
1991.3
4063.2
t =
0.02 K/m
p = 749
Líneas de Líquido
Ver nota a
1.00
0.91
40
50
Línea de Succión
Línea de
Descarga
1.11
1.00
0.88
0.80
La línea de caída de presión p es conservativa; si el sub-enfriamiento es sustancial o la
línea es corta, una línea de menor tamaño puede ser utilizada. Aplicaciones con sub enfriamiento muy pequeño o líneas muy largas pueden requerir una línea más grande.
1.10
30
b
1.18
20
Temperatura de
Condensación, °C
4. Valores basados en temperaturas de condensación de 40°c. Multiplicar las capacidades de
la tabla por los siguientes factores para otras temperaturas de condensación.
132.9
211.4
373.6
761.7
–40
Temperatura de Succión Saturada, °C
731
LINEA DE ACERO
106.4
169.5
299.5
610.6
Temperatura de Succión Saturada, °C
–30
–20
–5
Líneas de Succión (t = 0.04 K/m)
Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante 22 (Aplicaciones de Una o Alta Etapa)
[2010R, Ch 1, Tbl 3] (Continuo)
1. Las capacidades de la tabla están en kilovatios de refrigeración.
Notas:
50
65
80
100
Línea
Nominal
OD,
mm
Tabla 9.19 (SI)
09.fm Page 215 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
IPS
1/2
3/4
1
1 1/4
½
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
Acero
SCH
80
80
80
40
Cobre Tipo
L,
OD
Tamaño de Línea
Tabla 9.20 (I-P)
0.35
0.79
1.56
4.09
0.43
0.98
1.92
5.03
0.53
1.19
2.33
6.12
1.00
0.14
0.27
0.71
1.45
2.53
4.02
8.34
14.80
23.70
35.10
49.60
88.90
143.00
0.28
0.64
1.25
3.30
1.93
0.35
0.66
1.75
3.54
6.17
9.77
20.20
35.80
57.10
84.80
119.43
213.00
342.00
Correspondiente p, psi/100 ft
1.19
1.41
1.66
0.18
0.23
0.29
0.34
0.43
0.54
0.91
1.14
1.42
1.84
2.32
2.88
3.22
4.04
5.02
5.10
6.39
7.94
10.60
13.30
16.50
18.80
23.50
29.10
30.00
37.50
46.40
44.60
55.80
69.10
62.90
78.70
97.40
113.00
141.00
174.00
181.00
226.00
280.00
0
0.22
0.51
1.00
2.62
40
Temperatura de Succión Saturada, °F
10
20
30
Líneas de Succión (t = 2°F)
0.79
1.79
3.51
9.20
0
0.54
1.01
2.67
5.40
9.42
14.90
30.80
54.40
86.70
129.00
181.00
323.00
518.00
0.84
1.88
3.69
9.68
20
0.57
1.07
2.81
5.68
9.91
15.70
32.40
57.20
91.20
135.00
191.00
340.00
545.00
0.88
1.97
3.86
10.10
40
0.59
1.12
2.94
5.95
10.40
16.40
34.00
59.90
95.50
142.00
200.00
356.00
571.00
Temperatura de Succión
Saturada, °F
Líneas de Descarga
(t = 1°F, p = 2.2 psi/100 ft)
IPS
1/2
3/4
1
1 1/4
1/2
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
—
—
Acero
SCH
80
80
80
80
Cobre Tipo L,
OD
Tamaño de Línea
3.43
6.34
10.50
18.80
4.38
9.91
19.50
41.80
Velocidad t = 1°F
=
100 fpm p = 2.2
2.13
2.79
3.42
5.27
7.09
14.00
12.10
28.40
18.40
50.00
26.10
78.60
45.30
163.00
69.90
290.00
100.00
462.00
135.00
688.00
175.00
971.00
—
—
—
—
Ver Notas a y b
Líneas de Liquido
Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 134a (Aplicaciones de Una o Alta Etapa)
[2010R, Ch 1, Tbl 5]
Datos Refrigerantes
09.fm Page 216 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
216
SCH
40
40
40
40
40
3.94
7.60
12.10
21.40
43.80
1.00
0
20
30
4.95
9.56
15.20
26.90
54.90
6.14
11.90
18.90
33.40
68.00
7.54
14.60
23.10
41.00
83.50
Correspondiente p, psi/100 ft
1.19
1.41
1.66
10
Temperatura de Succión Saturada, °F
Líneas de Succión (t = 2°F)
9.18
17.70
28.20
49.80
101.60
1.93
40
a
 Actual L e  Capacidad Actual  1.8
 -----------------------  -----------------------------------------------
 Tabla L e  Capacidad de Tabla
Tamaño mostrado es recomendado donde cualquier gas generado en el receptor debe devolver hasta
la línea de condensado al condensador sin restringir el flujo de condensado. Los condensadores de
agua enfriada, donde la temperatura ambiente del receptor puede ser más alta que la temperatura de
condensación del refrigerante, cae dentro de esta categoría.
t = Tabla t
 Tabla L e Actual t 0.55
Capacidad de Línea = Capacidad de Tabla  -----------------------  -----------------------
 Actual L e Tabla t 
3. Temperatura de saturación  para otras capacidades y longitudes equivalente Le
14.50
28.00
44.60
78.80
160.00
20
15.20
29.30
46.70
82.50
168.00
40
IPS
1 1/2
2
2 1/2
3
4
Acero
SCH
80
40
40
40
40
Cobre Tipo L,
OD
Tamaño de Línea
25.90
49.20
70.10
108.00
187.00
63.70
148.00
236.00
419.00
853.00
Velocidad t = 1°F
=
100 fpm p = 2.2
Líneas de Liquido
Ver Notas a y b
0.968
0.902
0.834
110
120
130
Línea de Descarga
1.156
1.078
1.026
0.961
0.882
0.804
La línea de caída de presión p es conservativa; si el sub-enfriamiento es sustancial o la línea es
corta, una línea de menor tamaño puede ser utilizada. Aplicaciones con sub enfriamiento muy
pequeño o líneas muy largas pueden requerir una línea más grande
1.032
b
1.095
90
100
Línea de Succión
1.158
80
Temperatura de Condensación, °F
4. Valores basados en temperatura de condensación de 105°F. Multiplicar las capacidades de la tabla
por los siguientes factores para otras temperaturas de condensación.
13.80
26.60
42.40
75.00
153.00
0
Temperatura de Succión
Saturada, °F
Líneas de Descarga
(t = 1°F, p = 2.2 psi/100 ft)
Succión, Descarga y Capacidades de Línea de Líquido en Toneladas de Refrigerante 134a (Aplicaciones de Una o Alta Etapa)
[2010R, Ch 1, Tbl 5] (Continuo)
Notas:
1. Las capacidades de la tabla están en toneladas de refrigeración.
p = Caída de presión de la línea de fricción, psi por 100 pie de longitud de línea equivalente
t = cambio correspondiente en temperatura de saturación, °F por 100 pie
2. Capacidad de línea para otras temperaturas de saturación t y longitudes equivalente Le
IPS
1 1/2
2
2 1/2
3
4
Acero
Cobre Tipo
L,
OD
Tamaño de Línea
Tabla 9.20 (I-P)
09.fm Page 217 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
217
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
0.62
1.18
2.06
3.64
7.19
13.20
21.90
43.60
77.70
120.00
257.00
0.87
1.62
3.41
6.45
13.30
20.00
10
15
20
25
32
40
318
–10
Líneas de Succión (t = 0.04 K/m)
Líneas de Descarga
(t = 0.02 K/m, p = 538 Pa/m)
Temperatura de Succión Saturada, °C
–5
0
5
10
Temperatura de Succión Saturada, °C
Correspondiente p, Pa/m
368
425
487
555
–10
0
10
LINEA DE COBRE TIPO L
0.76
0.92
1.11
1.33
1.69
1.77
1.84
1.45
1.76
2.12
2.54
3.23
3.37
3.51
2.52
3.60
3.69
4.42
5.61
5.85
6.09
4.45
5.40
6.50
7.77
9.87
10.30
10.70
8.80
10.70
12.80
15.30
19.50
20.30
21.10
16.10
19.50
23.50
28.10
35.60
37.20
38.70
26.80
32.40
39.00
46.50
59.00
61.60
64.10
53.20
64.40
77.30
92.20
117.00
122.00
127.00
94.60
115.00
138.00
164.00
208.00
217.00
226.00
147.00
177.00
213.00
253.00
321.00
335.00
349.00
313.00
379.00
454.00
541.00
686.00
715.00
744.00
LINEA DE ACERO
1.06
1.27
1.52
1.80
2.28
2.38
2.47
1.96
2.36
2.81
3.34
4.22
4.40
4.58
4.13
4.97
5.93
7.02
8.88
9.26
9.64
7.81
9.37
11.20
13.30
16.70
17.50
18.20
16.10
19.40
23.10
27.40
34.60
36.10
37.50
24.20
29.10
34.60
41.00
51.90
54.10
56.30
t = 0.02 K/m
p = 538 Pa/m
8.50
16.30
28.40
50.10
99.50
183.00
304.00
605.00
1080.00
1670.00
3580.00
12.30
22.80
48.20
91.00
188.00
283.00
Velocidad =
0.5 m/s
6.51
10.60
16.00
24.50
41.00
64.90
95.20
160.00
248.00
346.00
618.00
9.81
15.60
27.40
44.40
76.90
105.00
Líneas de Líquido
Ver Nota a
Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante134a (Aplicaciones de una o Alta Etapa)
[2010R, Ch 1, Tbl 5]
12
15
18
22
28
35
42
54
67
79
105
Línea
Nominal OD,
mm
Tabla 9.20 (SI)
Datos Refrigerantes
09.fm Page 218 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
218
38.60
61.50
109.00
222.00
318
–10
219
 Actual L e  Actual capacity 1.8
 -----------------------  -------------------------------------
 Table L e  Table capacity
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
546.00
871.00
1540.00
3140.00
t = 0.02 K/m
p = 538 Pa/m
Línea de Descarga
0.682
0.856
1.0
1.110
20
30
40
50
1.239
1.120
1.0
0.888
Temperatura de Condensación, °C Línea de Succión
. aTamaño es recomendado donde cualquier gas generado en el receptor debe devolver hasta la línea de con- bLa línea de caída de presión p es conservativa; si el sub-enfriamiento es sustancial o la línea
densado al condensador sin restringir el flujo de condensado. Los condensadores de agua enfriada, donde
es corta, una línea de menor tamaño puede ser utilizada. Aplicaciones con sub enfriamiento
la temperatura ambiente del receptor puede ser más alta que la temperatura de condensación del refriger- muy pequeño o líneas muy largas pueden requerir una línea más grande
ante, cae dentro de esta categoría.
t = Tabla t
3. Temperatura de saturación t para otras capacidades y longitudes equivalentes Le
173.00
246.00
380.00
655.00
Velocidad =
0.5 m/s
Líneas de Líquido
Ver Nota a
4. Valores basados en 40°cd e temperatura de condensación. Multiplicar las capacidades de la
tabla por los siguientes factores para otras temperaturas de condensación
Líneas de Succión (t = 0.04 K/m)
Líneas de Descarga
(t = 0.02 K/m, p = 538 Pa/m)
Temperatura de Succión Saturada, °C
–5
0
5
10
Temperatura de Succión Saturada, °C
Correspondiente p, Pa/m
368
425
487
555
–10
0
10
LINEA DE ACERO (Continuado)
46.70
56.00
66.80
79.10
100.00
104.00
108.00
74.30
89.30
106.00
126.00
159.00
166.00
173.00
131.00
158.00
288.00
223.00
281.00
294.00
306.00
268.00
322.00
383.00
454.00
573.00
598.00
622.00
Succión, Descarga y Capacidades de Línea de Líquido en Kilovatios de Refrigerante134a (Aplicaciones de una o Alta Etapa)
[2010R, Ch 1, Tbl 5] (Continuo)
Notas:
1. Las capacidades de la tabla están en kilovatios de refrigeración.
p = caída de presión por longitud de línea equivalente Pa/m
t = cambio correspondiente en temperatura de saturación, K/m
2. Capacidad de línea para otras temperaturas de saturación t y longitudes equivalentes Le
 Table L e Actual t 0.55
Capacidad de Línea = Capacidad de Tabla  -----------------------  -----------------------
 Actual L e Table t 
50
65
80
100
Línea
Nominal OD,
mm
Tabla 9.20 (SI)
09.fm Page 219 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
22
40.0
20.0
0.0
–20.0
–40.0
–30.0
–10.0
10.0
–10.0
10.0
30.0
10.0
30.0
50.0
30.0
50.0
70.0
50.0
70.0
90.0
Temp.de
Temp
Succión
Gas de
Refrigerante
Saturada., Succión.,
°F
°F
5/8
0.233
0.119
0.117
0.118
0.156
0.153
0.154
0.199
0.194
0.195
0.244
0.242
0.242
0.300
0.296
0.296
1/2
0.146
0.067
0.065
0.066
0.087
0.085
0.086
0.111
0.108
0.109
0.136
0.135
0.135
0.167
0.165
0.165
7/8
0.484
0.298
0.292
0.295
0.389
0.362
0.383
0.496
0.484
0.486
0.608
0.603
0.605
0.748
0.737
0.738
3/4
0.348
0.197
0.194
0.195
0.258
0.253
0.254
0.328
0.320
0.322
0.403
0.399
0.400
0.495
0.488
0.488
0.825
0.580
0.570
0.575
0.758
0.744
0.747
0.986
0.942
0.946
1.18
1.17
1.18
1.46
1.44
1.44
1 1/8
Tubería OD,pulg.
1 3/8
1 5/8
Area, pulg2
1.256
1.780
0.981
1.52
0.963
1.49
0.972
1.50
1.28
1.98
1.26
1.95
1.26
1.95
1.63
2.53
1.59
2.46
1.60
2.47
2.00
3.10
1.99
3.07
1.99
3.08
2.46
3.81
2.43
3.75
2.43
3.76
3.094
3.03
2.97
3.00
3.96
3.88
3.90
5.04
4.92
4.94
6.18
6.13
6.15
7.60
7.49
7.50
2 1/8
4.770
5.20
5.11
5.15
6.80
6.67
6.69
8.66
8.45
8.48
10.6
10.5
10.6
13.1
12.9
12.9
2 5/8
6.812
8.12
7.97
8.04
10.6
10.4
10.4
13.5
13.2
13.2
16.6
16.4
16.5
20.4
20.1
20.1
3 1/8
9.213
11.8
11.6
11.7
15.5
15.2
15.2
19.7
19.2
19.3
24.2
24.0
24.0
29.7
29.3
29.3
3 5/8
11.970
16.4
16.1
16.3
21.5
21.1
21.1
27.4
26.7
26.8
33.5
33.3
33.3
41.3
40.7
40.7
4 1/8
Tabla 9.21 (I-P) Capacidad de Refrigeración Mínima en Toneladas para Arrastre de Petróleo hasta los Elevadores de Succión (Tubería de Cobre Tipo L)
[2010R, Ch 1, Tbl 20]
Datos Refrigerantes
09.fm Page 220 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
220
40.0
30.0
20.0
10.0
0.0
10.0
30.0
50.0
20.0
40.0
60.0
30.0
50.0
70.0
40.0
60.0
80.0
50.0
70.0
90.0
Temp.de
Temp
Succión
Gas de
Saturada., Succión.,
°F
°F
5/8
0.233
0.161
0.135
0.130
0.182
0.152
0.147
0.205
0.172
0.166
0.207
0.193
0.187
0.232
0.212
0.206
1/2
0.146
0.089
0.075
0.072
0.101
0.084
0.081
0.113
0.095
0.092
0.115
0.107
0.103
0.128
0.117
0.114
Notas:
1. La capacidad de refrigeración está basada en temperatura líquida de 90°F
y sobrecalentamiento como está indicado por la temperatura que aparece.
Para otras temperaturas de línea de líquido, use factores de corrección en
la tabla de la derecha.
2. Valores calculados utilizando ISO 32 aceite mineral para R-22. R-134a
calculado usando ISO 32 aceite basado en ester.
134a
Refrigerante
50
1.17
1.26
22
134a
0.484
0.400
0.336
0.323
0.453
0.379
0.366
0.510
0.427
0.413
0.517
0.480
0.465
0.577
0.528
0.512
7/8
Refrigerante
0.348
0.259
0.218
0.209
0.294
0.246
0.237
0.331
0.277
0.268
0.335
0.311
0.301
0.374
0.342
0.332
3/4
1.20
1.14
60
0.825
0.78
0.66
0.63
0.88
0.74
0.71
0.99
0.83
0.81
1.01
0.94
0.91
1.12
1.03
1.00
1 1/8
1.13
1.10
70
3.094
4.06
3.42
3.28
4.61
3.86
3.73
5.19
4.34
4.20
5.25
4.88
4.72
5.87
5.37
5.21
2 1/8
4.770
7.0
5.9
5.6
7.9
6.6
6.4
8.9
7.5
7.2
9.0
8.4
8.1
10.1
9.2
8.9
2 5/8
1.07
1.06
0.94
0.98
0.87
0.94
Temperatura de Líquido, °F
80
100
110
Tubería OD,pulg.
1 3/8
1 5/8
Area, pulg2
1.256
1.780
1.32
2.03
1.11
1.71
1.07
1.64
1.49
2.31
1.25
1.93
1.21
1.87
1.68
2.60
1.41
2.17
1.36
2.10
1.70
2.63
1.58
2.44
1.53
2.37
1.90
2.94
1.74
2.69
1.69
2.61
0.80
0.89
120
6.812
10.9
9.2
8.8
12.4
10.3
10.0
13.9
11.6
11.3
14.1
13.1
12.7
15.7
14.4
14.0
3 1/8
0.74
0.85
130
9.213
15.9
13.4
12.8
18.0
15.1
14.6
20.3
17.0
16.4
20.5
19.1
18.5
22.9
21.0
20.4
3 5/8
0.67
0.80
140
11.970
22.1
18.5
17.8
25.0
20.9
20.2
28.2
23.6
22.8
28.5
26.5
25.6
31.8
29.1
28.3
4 1/8
Tabla 9.21 (I-P) Capacidad de Refrigeración Mínima en Toneladas para Arrastre de Petróleo hasta los Elevadores de Succión (Tubería de Cobre Tipo L)
[2010R, Ch 1, Tbl 20] (Continuo)
09.fm Page 221 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
221
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Temp.de
Temp.
RefrigGas de
Saturada,
erante
Succión,
°C
°C
22
–40
–35
–25
–15
–20
–15
–5
5
–5
0
10
20
5
10
20
30
15
0.334
0.317
0.307
0.527
0.501
0.485
0.713
0.676
0.650
0.862
0.807
0.774
12
0.182
0.173
0.168
0.287
0.273
0.264
0.389
0.369
0.354
0.470
0.440
0.422
0.561
0.532
0.516
0.885
0.841
0.815
1.198
1.136
1.092
1.449
1.356
1.301
18
28
1.817
1.723
1.672
2.867
2.724
2.638
3.879
3.678
3.537
4.692
4.393
4.213
22
0.956
0.907
0.880
1.508
1.433
1.388
2.041
1.935
1.861
2.468
2.311
2.217
3.223
3.057
2.967
5.087
4.834
4.680
6.883
6.526
6.275
8.325
7.794
7.476
35
5.203
4.936
4.791
8.213
7.804
7.555
11.112
10.535
10.131
13.441
12.582
12.069
42
54
9.977
9.464
9.185
15.748
14.963
14.487
21.306
20.200
19.425
25.771
24.126
23.141
Tubería Nominal OD, mm
14.258
16.371
15.888
27.239
25.882
25.058
36.854
34.940
33.600
44.577
41.731
40.027
67
26.155
24.811
24.080
41.283
39.226
37.977
55.856
52.954
50.924
67.560
63.246
60.665
79
Tabla 9.21 (SI) Capacidad de Refrigeración Mínima en Kilovatios para Arrastre de Petróleo
hasta los Elevadores de Succión (Tubería de Cobre, ASTM B 88M Tipo B, Tamaño Métrico) [2010R, Ch 1, Tbl 19]
Datos Refrigerantes
09.fm Page 222 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
53.963
51.189
49.681
85.173
80.929
78.353
115.240
109.254
105.065
139.387
130.488
125.161
105
93.419
88.617
86.006
147.449
140.102
135.642
199.499
189.136
181.884
241.302
225.896
216.675
130
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
222
223
15
0.502
0.450
0.436
0.543
0.500
0.484
0.655
0.615
0.582
0.721
0.679
0.657
12
0.274
0.245
0.238
0.296
0.273
0.264
0.357
0.335
0.317
0.393
0.370
0.358
18
0.844
0.756
0.732
0.913
0.840
0.813
1.100
1.033
0.978
1.211
1.141
1.104
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
22
1.437
1.287
1.247
1.555
1.431
1.386
1.874
1.761
1.667
2.063
1.944
1.881
28
2.732
2.447
2.370
2.956
2.720
2.634
3.562
3.347
3.168
3.921
3.695
3.576
4.848
4.342
4.206
5.244
4.827
4.674
6.321
5.938
5.621
6.957
6.555
6.345
35
7.826
7.010
6.790
8.467
7.792
7.546
10.204
9.586
9.075
11.232
10.583
10.243
42
54
67
79
39.340
35.235
34.129
42.559
39.168
37.929
51.292
48.184
45.617
56.456
53.195
51.486
105
81.164
72.695
70.414
87.806
80.809
78.254
105.823
99.412
94.115
116.479
109.749
106.224
1.17
1.20
134a
20
1.10
1.08
30
0.89
0.91
50
Temperatura de Líquido, °C
25.957
23.248
22.519
28.081
25.843
25.026
33.843
31.792
30.099
37.250
35.098
33.971
22
Refrigerante
15.006
13.440
13.019
16.234
14.941
14.468
19.565
18.380
17.401
21.535
20.291
19.640
Tubería Nominal OD, mm
Notas:
1. La capacidad de refrigeración en kilovatios está basada en evaporador saturado como está indicado en la tabla y temperatura de condensación de 40°C. Para otras temperaturas de línea de líquido, use los factores de corrección en la tabla
de la derecha.
2. Valores calculados utilizando ISO 32 aceite mineral para R-22 y R-502. R-134a calculado utilizando ISO 32 aceite
basado en ester.
Temp.de
Temp.
RefrigGas de
Saturada,
erante
Succión.,
°C
°C
134a
–10
–5
5
15
–5
0
10
20
5
10
20
30
10
15
25
35
Tabla 9.21 (SI) Capacidad de Refrigeración Mínima en Kilovatios para Arrastre de Petróleo
hasta los Elevadores de Succión (Tubería de Cobre, ASTM B 88M Tipo B, Tamaño Métrico) [2010R, Ch 1, Tbl 19] (Continuo)
09.fm Page 223 Thursday, March 3, 2016 12:46 PM
130
140.509
125.847
121.898
152.006
139.894
135.471
183.197
172.098
162.929
201.643
189.993
183.891
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
22
120.0
110.0
100.0
90.0
80.0
110.0
140.0
170.0
120.0
150.0
180.0
130.0
160.0
190.0
140.0
170.0
200.0
150.0
180.0
210.0
Temp. Temp. de
Refrigerante Saturada, Descarga
°F
de Gas, °F
5/8
0.233
0.421
0.399
0.385
0.433
0.406
0.387
0.442
0.414
0.394
0.451
0.421
0.399
0.460
0.428
0.404
1/2
0.146
0.235
0.223
0.215
0.242
0.226
0.216
0.247
0.231
0.220
0.251
0.235
0.222
0.257
0.239
0.225
7/8
0.484
1.05
0.996
0.960
1.06
1.01
0.956
1.10
1.03
0.982
1.12
1.05
0.994
1.15
1.07
1.01
3/4
0.348
0.695
0.659
0.635
0.716
0.671
0.540
0.730
0.884
0.650
0.744
0.693
0.658
0.760
0.707
0.666
0.825
2.03
1.94
1.87
2.11
1.97
1.88
2.15
2.01
1.91
2.19
2.05
1.94
2.24
2.08
1.96
1 1/8
Tubería OD, pulg.
1 3/8
1 5/8
Area, pulg2
1.256
1.780
3.46
5.35
3.28
5.07
3.16
4.89
3.56
5.50
3.34
5.16
3.18
4.92
3.83
5.62
3.40
5.26
3.24
3.00
3.70
5.73
3.46
3.35
3.28
5.06
3.78
5.85
3.51
5.44
3.31
5.12
3.094
10.7
10.1
9.76
11.0
10.3
9.82
11.2
10.5
9.96
11.4
10.7
10.1
11.7
10.8
10.2
2 1/8
4.770
18.3
17.4
16.8
18.9
17.7
16.9
19.3
18.0
17.2
19.6
18.3
17.4
20.0
18.6
17.6
2 5/8
6.812
28.6
27.1
26.2
29.5
27.6
26.3
30.1
28.2
26.8
30.6
28.6
27.1
31.3
29.1
27.4
3 1/8
Tabla 9.22 (I-P) Capacidad de Refrigeración Mínima en Toneladas para Arrastre de Petróleo
hasta los Elevadores de Gas Caliente (Tubería de Cobre Tipo L)
[2010R, Ch 1, Tbl 19]
Datos Refrigerantes
09.fm Page 224 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
9.213
41.8
39.6
38.2
43.0
40.3
38.4
43.9
41.1
39.1
44.7
41.8
39.5
45.7
42.4
40.0
3 5/8
11.970
57.9
54.9
52.9
59.6
55.9
53.3
60.8
57.0
54.2
62.0
57.9
54.8
63.3
58.9
55.5
4 1/8
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
224
120.0
110.0
100.0
90.0
80.0
110.0
140.0
170.0
120.0
150.0
180.0
130.0
160.0
190.0
140.0
170.0
200.0
150.0
180.0
210.0
5/8
0.233
0.360
0.331
0.318
0.364
0.333
0.320
0.372
0.340
0.326
0.378
0.346
0.331
0.383
0.351
0.334
1/2
0.146
0.199
0.183
0.176
0.201
0.184
0.177
0.206
0.188
0.180
0.209
0.191
0.183
0.212
0.194
0.184
0.348
0.581
0.535
0.512
0.587
0.538
0.516
0.600
0.549
0.526
0.610
0.558
0.534
0.618
0.566
0.538
3/4
0.484
0.897
0.825
0.791
0.906
0.830
0.796
0.926
0.848
0.811
0.942
0.861
0.824
0.953
0.873
0.830
7/8
0.825
1.75
1.61
1.54
1.76
1.62
1.55
1.80
1.65
1.58
1.83
1.68
1.61
1.86
1.70
1.62
1 1/8
3.094
9.12
8.39
8.04
9.21
8.44
8.09
9.42
8.62
8.25
9.57
8.76
8.38
9.69
8.88
8.44
2 1/8
6.812
24.4
22.5
21.6
24.7
22.6
21.7
25.2
23.1
22.1
25.7
23.5
22.5
26.0
23.8
22.6
3 1/8
9.213
35.7
32.8
31.4
36.0
33.0
31.6
36.8
33.7
32.2
37.4
34.2
32.8
37.9
34.7
33.0
3 5/8
11.970
49.5
45.6
43.6
50.0
45.8
43.9
51.1
46.8
44.8
52.0
47.5
45.5
52.6
48.2
45.8
4 1/8
0.92
—
134a
–40
—
0.95
–20
0.96
0.97
0
1.04
1.02
+40
Temperatura de Succión Saturada, °F
4.770
15.7
14.4
13.8
15.8
14.5
13.9
16.2
14.8
14.2
16.5
15.0
14.4
16.7
15.3
14.5
2 5/8
22
Refrigerante
Tubería OD, pulg.
1 3/8
1 5/8
Area, pulg2
1.256
1.780
2.96
4.56
2.72
4.20
2.61
4.02
2.99
4.61
2.74
4.22
2.62
4.05
3.05
4.71
2.79
4.31
2.67
4.13
3.10
4.79
2.84
4.38
2.72
4.19
3.14
4.85
2.88
4.44
2.74
4.23
Notas
1. Capacidad de refrigeración en toneladas basada en temperatura de succión saturada de 20°F con sobrecalentamiento de
15°F en la temperatura de condensación saturada indicada con 15°F de subenfriamiento. Para otras temperaturas de succión saturada con 15°F de sobrecalentamiento, use los factores de corrección de la tabla de la derecha.
2. Tabla calculada utilizando ISO 32 aceite mineral para R-22, y ISO 32 aceite basado en ester para R-134a.
134a
Temp. Temp. de
Refrigerante Saturada, Descarga
°F
de Gas, °F
Tabla 9.22 (I-P) Capacidad de Refrigeración Mínima en Toneladas para Arrastre de Petróleo
hasta los Elevadores de Gas Caliente (Tubería de Cobre Tipo L)
[2010R, Ch 1, Tbl 19] (Continuo)
09.fm Page 225 Thursday, March 3, 2016 12:46 PM
Datos Refrigerantes
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
225
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
22
Refrigerante
50
40
30
20
0.630
0.611
0.595
100
110
0.584
90
1.103
0.601
90
100
1.092
1.121
1.156
1.071
1.132
0.035
1.062
1.092
0.982
1.006
0.032
15
0.618
0.565
90
80
0.579
80
0.535
80
0.596
0.549
70
70
0.563
60
12
22
2.956
2.881
2.811
3.127
3.040
2.964
3.242
3.157
3.067
3.310
3.209
3.125
18
0.735
1.691
1.650
1.836
1.785
1.740
1.903
1.853
1.800
1.943
1.884
1.834
5.941
6.100
6.291
5.830
6.001
6.163
5.635
5.779
5.945
5.343
5.477
5.619
28
10.540
10.823
11.162
10.343
10.647
10.934
9.998
10.254
10.547
9.480
9.717
9.969
35
17.016
17.473
18.020
16.698
17.189
17.653
16.140
16.554
17.028
15.305
15.687
16.094
42
32.627
33.503
34.552
32.018
32.959
33.847
30.948
31.740
32.649
29.346
30.078
30.859
54
Diámetro de Tubería, Nominal OD, mm
56.435
57.951
59.766
55.382
47.009
58.546
53.531
54.901
56.474
50.761
52.027
43.377
67
85.532
87.831
90.580
83.936
86.403
88.732
81.131
83.208
85.591
76.933
48.851
80.897
79
130
176.467 305.493
181.209 313.702
186.882 323.523
173.173 299.791
178.263 308.603
183.069 316.922
167.386 289.773
171.671 297.190
176.588 305.702
158.726 173.780
162.682 281.630
116.904 288.938
105
Capacidad de Refrigeración Míníma en Kilovatios para Arrastre de Petróleo hasta los Elevadores de Gas Caliente
(Tubería de Cobre, ASTM B 88M Tipo B, Tamaño Métrico) [2010R, Ch 1, Tbl 20]
Temp. de
Temp. de
Descarga
Descarga
Saturada, °C de Gas., °C
Tabla 9.22 (SI)
Datos Refrigerantes
09.fm Page 226 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
226
227
50
40
30
20
0.510
0.479
0.467
100
110
0.465
90
0.874
0.477
90
100
0.857
0.878
0.936
0.852
0.930
0.829
0.849
0.904
0.790
0.808
0.860
15
0.507
0.452
90
80
0.463
80
0.431
80
0.493
0.441
70
70
0.469
12
60
Temp. de
Temp. de
Descarga
Descarga
Saturada, °C de Gas., °C
1.441
1.476
1.573
1.432
1.469
1.563
1.393
1.426
1.519
1.327
1.358
1.445
18
4.665
4.779
5.093
4.637
4.756
5.061
4.513
4.260
4.918
4.298
4.399
4.681
28
22
134a
–50
0.87
—
8.278
8.480
9.037
8.227
8.439
8.979
8.007
8.196
8.726
7.626
7.805
8.305
35
54
25.624
26.248
27.973
25.466
26.122
27.794
24.785
25.371
27.011
23.605
24.159
25.709
67
44.322
45.402
48.385
44.048
45.184
48.075
42.870
43.885
46.722
40.830
41.788
44.469
79
67.173
68.811
73.332
66.759
68.480
72.863
64.974
66.512
70.812
61.881
63.334
67.396
105
130
10
—
1.06
138.590 239.921
141.969 245.772
151.296 261.918
137.735 238.443
141.285 244.588
150.328 260.242
134.052 232.066
137.225 237.560
145.096 252.916
127.671 221.020
130.668 226.207
139.050 240.718
Temperatura de Succión Saturada, °C
–40
–30
–20
0
5
0.90
0.93
0.96
—
1.02
—
—
—
1.02
1.04
13.364
13.690
14.589
13.281
13.624
14.496
12.926
13.232
14.087
12.311
12.600
13.408
42
Diámetro de Tubería, Nominal OD, mm
Refrigerante
2.454
2.514
2.679
2.439
2.502
2.662
2.374
2.430
2.587
2.261
2.314
2.462
22
Capacidad de Refrigeración Míníma en Kilovatios para Arrastre de Petróleo hasta los Elevadores de Gas Caliente
(Tubería de Cobre, ASTM B 88M Tipo B, Tamaño Métrico) [2010R, Ch 1, Tbl 20] (Continuo)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
1. La capacidad de refrigeración en kilovatios está basada en el evaporador saturada a 5°C,
y la temperatura de condensación como está indicado en la tabla. Para otras temperaturas de línea de líquido , use los factores de corrección en la tabla de la derecha.
2. Valores calculados utilizando ISO 32 aceite mineral para R-22, e ISO 32 aceite basado
en ester para R-134a.
Notas:
134a
Refrigerante
Tabla 9.22 (SI)
09.fm Page 227 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
80
80
80
80
40
40
40
40
40
40
40
40
40
40
ID*
3/8
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
5
6
8
10
12
–40
p = 0.31
—
—
—
—
3.2
4.9
9.5
15.3
27.1
55.7
101.1
164.0
337.2
611.6
981.6
Líneas de Succión (t = 1°F)
Temperatura de Succión Saturada, °F
–20
0
20
p = 0.49
p = 0.73
p = 1.06
—
—
—
—
—
—
—
—
2.6
2.1
3.4
5.2
5.6
8.9
13.6
8.4
13.4
20.5
16.2
26.0
39.6
25.9
41.5
63.2
46.1
73.5
111.9
94.2
150.1
228.7
170.4
271.1
412.4
276.4
439.2
667.5
566.8
901.1
1366.6
1027.2
1634.3
2474.5
1644.5
2612.4
3963.5
t = Tabla t
 Actual L e  Actual capacity 1.8
 -----------------------  -------------------------------------
 Table L e  Table capacity
3. Temperatura de saturación t para otras capacidades y longitudes equivalentes Le
 -----------------------  -----------------------
 Actual L e Table t 
Notas:
1. Las capacidades de la tabla están en toneladas de refrigeración.
p = caída de presión debido a línea de fricción psi por 100 pie de longitud equivalente
t = cambio correspondiente en temperatura de saturación, °F por 100 pie
2. Capacidad de línea para otras temperaturas de saturación t y longitudes equivalentes Le
 Table L e Actual t 0.55
Capacidad de Línea = Capacidad de Tabla
SCH
IPS
Tamaño de Línea de
Acero
—
3.1
7.1
13.9
36.5
54.8
105.7
168.5
297.6
606.2
1095.2
1771.2
3623.0
—
—
Líneas de
Descarga
t = 1°F
p = 2.95
3/8
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
4
5
6
8
10
12
IPS
80
80
80
80
80
80
40
40
40
40
40
40
40
40
ID*
SCH
Tamaño de Línea de
Acero
p =2.0 psi
t = 0.7°F
12.1
24.0
54.2
106.4
228.6
349.2
811.4
1292.6
2287.8
4662.1
—
—
—
—
—
Líneas de Líquido
Velocidad =
100 fpm
8.6
14.2
26.3
43.8
78.1
107.5
204.2
291.1
449.6
774.7
—
—
—
—
—
Líneas de Descarga
0.78
0.89
1.00
1.11
Líneas de Succión
1.05
1.02
1.00
0.98
5. Capacidades de línea de líquido y descarga basadas en succión de 20°F. La temperature del evaporador es 0°F. La capacidad está afectada menos del 3% cuando es aplicada de extremos de –40 to +40°F
Temperatura de
Condensación, °F
70
80
90
100
4. Valores basados en temperatura de condensación de 90°F Multiplicar las capacidades de la table por
los siguientes factores para otras temperaturas de condensación:
40
p = 1.46
—
—
3.8
7.6
19.9
29.9
57.8
92.1
163.0
333.0
600.9
971.6
1989.4
3598.0
5764.6
Tabla 9.23 (I-P) Succión, Descarga y Capacidades de Línea de Líquido (Aplicaciones de Un o Etapa Alta) [2010R, Ch 2, Tbl 2]
Datos Refrigerantes
09.fm Page 228 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
228
–40
Δp = 76.9
0.8
1.4
3.0
5.8
12.1
18.2
35.4
56.7
101.0
206.9
375.2
608.7
1252.3
2271.0
3640.5
Líneas de Succión (Δt = 0.02 K/m)
Temperatura de Succión Saturada, °C
–30
–20
–5
Δp = 116.3 Δp = 168.8 Δp = 276.6
1.2
1.9
3.5
2.3
3.6
6.5
4.9
7.7
13.7
9.4
14.6
25.9
19.6
30.2
53.7
29.5
45.5
80.6
57.2
88.1
155.7
91.6
140.6
248.6
162.4
249.0
439.8
332.6
509.2
897.8
601.8
902.6
1622.0
975.6
1491.4
2625.4
2003.3
3056.0
5382.5
3625.9
5539.9
9733.7
5813.5
8873.4
15568.9
+5
Δp = 370.5
4.9
9.1
19.3
36.4
75.4
113.3
218.6
348.9
616.9
1258.6
2271.4
3672.5
7530.4
13619.6
21787.1
 Actual L e  Actual capacity 1.8
 -----------------------  -------------------------------------
 Table L e  Table capacity
Datos Refrigerantes
229
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Δt = Tabla Δt
3. Temperatura de saturación Δt para otras capacidades y longitudes equivalentes Le
 -----------------------  -----------------------
 Actual L e Table t 
Notas:
1. Las capacidades de la tabla están en kilovatios de refrigeración.
Δp = caída de presión debido a fricción de línea, Pa/m
Δt = Cambio correspondiente en temperatura de saturación, K/m
2. Capacidad de línea para otras temperaturas de saturación Δt y longitudes equivalentes Le
 Table L e Actual t 0.55
Línea de capacidad = Capacidad de Tabla
10
15
20
25
32
40
50
65
80
100
125
150
200
250
300
Tamaño de
Línea
Nominal de
Acero, mm
10
15
20
25
32
40
50
65
80
10
—
—
—
—
—
Tamaño de
Línea
Nominal de
Acero, mm
63.8
118.4
250.2
473.4
978.0
1469.4
2840.5
4524.8
8008.8
63.8
—
—
—
—
—
Δp = 450.0
Líneas de Líquido
Velocidad =
0.5 m/s
3.9
63.2
110.9
179.4
311.0
423.4
697.8
994.8
1536.3
3.9
—
—
—
—
—
Líneas de Descarga
0.86
1.00
1.24
1.43
Líneas de Succión
1.04
1.00
0.96
0.91
5. Capacidades de línea de líquido basado en succión −5°C.
Temperatura de
Condensación, °C
20
30
40
50
4. Los valores están basados en temperatura de condensación de 30°C. Multiplicar las capacidades de la
tabla por los siguientes factores para otras temperaturas de condensación:
Líneas de Descarga
Δt = 0.02 K/m, Δp = 684.0 Pa/m
Temperatura de Succión Saturada °C
–40
–20
+5
8.0
8.3
8.5
14.9
15.3
15.7
31.4
32.3
33.2
59.4
61.0
62.6
122.7
126.0
129.4
184.4
189.4
194.5
355.2
364.9
374.7
565.9
581.4
597.0
1001.9
1029.3
1056.9
2042.2
2098.2
2154.3
3682.1
3783.0
3884.2
5954.2
6117.4
6281.0
12 195.3
12 529.7
12 864.8
22 028.2
22 632.2
23 237.5
35 239.7
36 206.0
37 174.3
Tabla 9.23 (SI) Succión, Descarga y Capacidades de Líquido en Kilovatios para Amoniaco (Aplicaciones de Una o Alta Etapa) [2010R, Ch 2, Tbl 2]
09.fm Page 229 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
110
250
43
93.5
146
334
533
768
1365
—
—
—
1
1¼
1½
2
2½
3
4
5
6
8
—
—
—
819
461
320
200
87.5
56
26
13
6
5:1
153–246
247–411
—
—
—
—
—
—
—
39–64
439
2886
28–38
286
65–107
16–27
134
108–152
9–15
69
1616
—
30
1016
Descongelamiento
de Gas Calientea
Líquido de Alta
Presión
a 3 psia
—
—
—
2000
1000
500
300
225
150
100
50
—
Ecualizador
Lado Altob
8874
5130
3550
2261
1312
850
470
200
—
—
—
—
Suministro
5533
3200
2214
1410
870
530
300
120
—
—
—
—
Retorno
11596
6378
3624
2000
1102
638
362
203
—
—
—
—
Vent
Flujo por Gravedad de Líneas de Enfriamiento
de Termosifón Lubricante,c 1000 Btu/h
Fuente: Wile (1977).
a Clasificación para ramales de líneas de gas caliente bajo 100 pie con presión de entrada mínima de 105 psig, presión de descongelamiento de 70 psig, y evaporadores –20°F diseñados para una temperatura diferencial de 10°F.
b Tamaños de líneas basados en experiencia utilizando el total de toneladas del evaporador del sistema.
c De Frick Co. (1995). Valores por tamaños de línea sobre 4 pulg. son extrapolados.
—
—
—
1024
576
400
70
32.5
16.5
22
¾
7.5
4:1
10
3:1
Relación de Sobrealimentación
Líquido Bombeado
½
Tamaño
Nominal, pulg.
Tabla 9.24 (I-P) Capacidades de Línea de Amoniaco Líquido (Capacidad en Toneladas de Refrigeración, Excepto como se ha Señalado)
[2010R, Ch 2, Tbl 3]
Datos Refrigerantes
09.fm Page 230 Thursday, March 3, 2016 12:46 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
230
231
1875
2700
4800
—
—
—
65
80
100
125
150
200
4:1
—
—
—
3600
2026
1407
879
387
5:1
—
—
—
2880
1620
1125
703
308
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
—
—
—
—
10 150
5683
3573
1544
—
3411
2089
1154
570
324
176
106
Líquido de Alta
Descongelamiento
Presión
de Gas Calientea
a 21 kPaa
—
—
—
7034
3517
1759
1055
791
Ecualizador
Lado Altob
2600
1504
1041
663
385
249
138
59
Suministro
1622
938
649
413
255
155
88
35
Retorno
3400
1869
1062
586
323
187
106
60
Vent
Flujo por Gravedad de Líneas de
Enfriamiento de Termosifón lubricantec
Fuente: Wile (1977).
aClasificación para ramales de líneas de gas caliente bajo 30 m con una presión de entrada mínima de 724 kPa (calibrre), presión de descongelamiento de 483 kPa (calibre),y evaporadores –29°c diseñados
para una temperatura diferencial 5.6 K.
bTamaños de líneas basado en experiencia utilizando el total de kilovatios del evaporador del sistema.
c
De Frick Co. (1995). Valores para tamaños de línea sobre 100 mm son extrapolados.
1175
50
3:1
513
40
Tamaño
Nominal, mm
Capacidades de Línea de Amoniaco Líquido en Kilovatios [2010R, Ch 2, Tbl 3]
Relación de Sobrealimentación
Líquido Bombeado
Tabla 9.24 (SI)
09.fm Page 231 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
09.fm Page 232 Thursday, March 3, 2016 12:46 PM
El aceite en compresores refrigerantes lubrica, actúa como enfriador y sella la succión del
lado de la descarga. El aceite mezcla bien con los refrigerantes de hidrocarburos en temperaturas
altas, la miscibilidad es reducida como la temperatura decrece. El aceite sale dl compresor y se
disuelve en el refrigerante en el condensador y pasa a través de la línea del líquido al evaporador
donde se separa. En sistemas de mayor temperatura, regresa por gravedad o es arrastrada por el
vapor de retorno. Sistemas halocarbonados de temperatura baja necesitan un separador de aceite
en la descarga del compresor. Retorno de aceite hasta tuberías verticales requiere velocidad de
refrigerante significativa. Los lubricantes generalmente no son miscibles con amoniaco y se separan fácilmente del líquido. Separadores de aceite en la descarga de los compresores son esenciales. El aceite debe ser periódicamente o continuamente removido y retornado al compresor.
No hay un lubricante ideal. Para refrigerantes halocarbonados, hay lubricantes minerales,
ambos nafténicos y parafínicos y lubricantes sintéticos, éster y glicol. Los grados de viscosidad
requeridos varían con la temperatura y la solubilidad del refrigerante en el lubricante. Aditivos son
utilizados para mejorar las propiedades del lubricante o impactar nuevas características. Estos
pueden ser compuestos polares, polímeros o compuestos que contienen elementos activos como
azufre o fosforo. Los lubricantes deben estar secos; normalmente casi todos los lubricantes hidrocarburos tienen un contenido de humedad cerca de 30 ppm. Los lubricantes sintéticos polialquileno glicoles (PAGs) son comúnmente utilizados en automóviles sistemas R-134a;
polialfaolefinas (PAOs) son utilizados principalmente un aceite inmiscible en sistemas de amoniaco; ésteres de poliol son utilizados con refrigerantes HF en todos los tipos de compresores. Bajo
punto de fluidez es esencial para aceites en sistemas de amoniaco.
Tabla 9.25 (I-P) Comparaciones de Rendimiento de Refrigerante Secundario
[2010R, Ch 13, Tbl 1]
Concentración Punto de
(por Peso), Congelación, gpm/tona
%
°F
Caída de
Presión,b
psi
Coeficiente de
Transferencia de Calorc hi,
Btu/hyft2y°F
Glicol propileno
39
–5.1
2.56
2.91
205
Glicol etileno
38
–6.9
2.76
2.38
406
Metanol
26
–5.3
2.61
2.05
473
Cloruro de sodio
23
–5.1
2.56
2.30
558
Cloruro de calcio
22
–7.8
2.79
2.42
566
Agua amoniacal
14
–7.0
2.48
2.44
541
Tricloroetileno
100
–123
7.44
2.11
432
d-Limoneno
100
–142
6.47
1.48
321
Cloruro de metileno
100
–142
6.39
1.86
58
R-11
100
–168
7.61
2.08
428
a Basado en la temperatura de entrada del refrigerante secundario en la bomba de 25°F.
b Basado en una longitud de tubos de 16 ft con 1.06 pulg. Diámetro interior y utilización del Diagrama de Moody
(1944) para una velocidad promedio de 7 fps. Pérdidas de Entrada/salida igual una Vel. HD (V2/2g) para velocidad de 7 fps. Las evaluaciones están a una temperatura mayor de 20°F y un margen de temperatura de 10°F.
c Basadoen la curva de ajuste de ecuación de Kern (1950) adaptación de Sieder y Tate’s (1936) ecuación de transferencia
de calor utilizando tubos de 16 pie para L/D = 181 y temperatura de película de 5°F más baja que la temperatura mayor
promedio con velocidad de 7 fps.
232
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Datos Refrigerantes
Refrigerante
Secundario
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Lubricantes en Sistemas Refrigerantes
09.fm Page 233 Thursday, March 3, 2016 12:46 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 9.25 (SI) Comparaciones de Rendimiento de Refrigerante Secundario
[2010R, Ch 13, Tbl 1]
Coeficiente de
Punto de
Caída de
Concentración
Transferencia de Calorc
Congelación, L/(sykW)a
Presión,b kPa
(por Peso), %
hi, W/(m2·K
°C
Refrigerante
Secundario
Glicol propileno
39
–20.6
0.0459
20.064
1164
Glicol etileno
38
–21.6
0.0495
16.410
2305
Metanol
26
–20.7
0.0468
14.134
2686
Cloruro de sodio
23
–20.6
0.0459
15.858
3169
Cloruro de calcio
22
–22.1
0.0500
16.685
3214
Agua amoniacal
14
–21.7
0.0445
16.823
3072
Tricloroetileno
100
–86.1
0.1334
14.548
2453
d-Limoneno
100
–96.7
0.1160
10.204
1823
Cloruro de metileno
100
–96.7
0.1146
12.824
3322
R-11
100
–111.1
0.1364
14.341
2430
a
b
c
Basado en la temperatura de entrada del refrigerante secundario en la bomba de 3.9°C.
Basado en una longitud de tubos de 4.9 m con 26.8 mm. Diámetro interior y utilización del Diagrama de
Moody (1944) para una velocidad promedio de 213 m/s. Pérdidas de entrada/salida igual (V2/2g) para
velocidad de 2.13 m/s. Las evaluaciones están a una temperatura mayor de –6.7°Cc y un margen de temperatura de 5.6 K.
Basadoen la curva de ajuste de ecuación de Kern (1950) adaptación de Sieder y Tate’s (1936) ecuación de
transferencia de calor utilizando tubos de 4.9 m para L/D = 181 y temperatura de película de 2,8°C más baja
que la temperatura mayor promedio con velocidad de 2.134 m/s.
Tabla 9.26 Energía de Bombeo Relativo Requerida* [2010R, Ch 13, Tbl 3]
1.000
Metanol
1.078
Glicol propileno
1.142
Glicol etileno
1.250
Cloruro de sodio
1.295
Cloruro de calcio
1.447
d-Limoneno
2.406
Cloruro de metileno
3.735
Tricloroetileno
4.787
Agua amoniacal
1.000
Metanol
1.078
R-11
5.022
Datos Refrigerantes
Factor de Energía
Agua amoniacal
* Basado en la misma presión de la bomba, carga de refrigeración, 20°F (–6.7°C) temperatura promedio, 10°F (6 K)
margen, y punto de congelación (para refrigerantes secundarios a base de agua 20 to 23°F (11 to 13 K) debajo de la
temperatura de refrigeración secundaria más baja.
233
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Refrigerante Secundario
10.fm Page 234 Thursday, March 3, 2016 12:48 PM
SEGURIDAD DE REFRIGERANTES
Seguridad de Refrigerantes
234
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 10.1 Clasificación del Grupo de Seguridad del Refrigerante [Std 34-2010, Fig 1]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
10.
Dióxido de carbono
717
744
CH3CHF2
CF3CF=CH2
CO2
NH3
CH3CH2CH3
A2
A1
B2
A3
A2
A2
A1
B1
Al
Grupo de
Seguridad
16,000
40,000
320
5300
12,000
20,000
50,000
9100
59,000
(ppm v/v)
75
72
0.22
9.5
32
83
210
57
210
(g/m3)
RCLc
4.7
4.5
0.014
0.56
2.0
5.1
13
3.5
13
(lb/1000 ft3)
235
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Seguridad de Refrigerantes
la Norma 34 de ASHRAE.
b El nombre químico preferido está seguido por el nombre popular en paréntesis.
c Datos tomados de J.M. Calm, “Base de Datos de Refrigerante ARTI,” Instituto Tecnológico de Refrigeración y Aire Acondicionado (ARTI), Arlington, VA, Julio 2001; J.M. Calm, “Datos de Toxicidad
para Determinar los Límites de Concentración del Refrigerante,” Reporte DE/CE 23810-110, Instituto Tecnológico de Refrigeración y Aire Acondicionado (ARTI), Arlington, VA, Septiembre 2000;
J.M. Calm, “La Toxicidad de los Refrigerantes,” Actas de la Conferencia Internacional de Refrigeración 1966 , Purdue University, West Lafayette, IN, pp. 157–62, 1996; D.P. Wilson y R.G. Richard,
“Determinación de los Límites de Inflamabilidad Inferior del Refrigerante (LFLs) en cumplimiento con la Propuesta de Adenda p a la Norma 34-1992 de ANSI/ASHRAE (1073-RP),” Transacciones de
ASHRAE 2002, 108(2); D.W. Coombs, “HFC-32 Evaluación de la Potencia Anestésica en Ratones por Inhalación,” Huntingdon Life Sciences Ltd., Huntingdon, Cambridgeshire, Inglaterra, febrero 2004
y enmienda febrero 2006; D.W. Coombs, “HFC-22 Un Estudio de Evaluación para Investigar el Potencial de la Sensibilización Cardiaca en los Perros Beagle,” Huntingdon Life Sciences Ltd., Huntingdon, Cambridgeshire, Inglaterra, Agosto 2005; y otros estudios de toxicidad
a El nombre químico y fórmula química no son parte de esta norma. Los nombres químicos conforme a la nomenclatura IUPAC14,15 excepto donde nombres inequívocos acortados son utilizados siguiendo
2,3,3,3-tetrafluoro-1-propano
Amoniaco
290
1234yf
1,1-difluoretano
Propano
152a
CH3CClF2
CH2FCF3
1,1,1,2-tetrafluoretano
1-cloro-1,1-difluoretano
134a
142b
CHCl2CF3
2,2-dicloro-1,1,1-trifluoretano
CHClF2
Clorodifluormetano
Fórmula
Químicaa
22
Nombre Químicoa,b
Datos del Refrigerante y Clasificaciones de Seguridad [Std 34-2010, Tbl 1, Abreviado]
123
Número de
Refrigerante
Tabla 10.1
10.fm Page 235 Thursday, March 3, 2016 12:48 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
R-32/125 (50.0/50.0)
130,000
76,000
130,000
130,000
A1
A1
A1
A1
(±2.0/±1.0/±2.0)
(±2.0/±2.0/±2.0)
(+0.5, –1.5/+1.5, –0.5)
(ppm v/v)
Grupo de
Seguridad
Tolerancias de
Composición
520
390
270
500
(g/m3)
RCLa
32
25
17
31
(lb/1000 ft3)
Datos tomados de J.M. Calm, “Base de Datos de Refrigerante ARTI,” Instituto Tecnológico de Refrigeración y Aire Acondicionado (ARTI), Arlington, VA, Julio 2001; J.M. Calm, “Datos de Toxicidad
para Determinar los Límites de Concentración del Refrigerante,” Reporte DE/CE 23810-110, Instituto Tecnológico de Refrigeración y Aire Acondicionado (ARTI), Arlington, VA, Septiembre 2000; J.M.
Calm, “La Toxicidad de los Refrigerantes,” Actas de la Conferencia Internacional de Refrigeración 1966 , Purdue University, West Lafayette, IN, pp. 157–62, 1996; D.P. Wilson y R.G. Richard, “Determinación de los Límites de Inflamabilidad Inferior del Refrigerante (LFLs) en cumplimiento con la Propuesta de Adenda p a la Norma 34-1992 de ANSI/ASHRAE (1073-RP),” Transacciones de ASHRAE
2002, 108(2); D.W. Coombs, “HFC-32 Evaluación de la Potencia Anestésica en Ratones por Inhalación,” Huntingdon Life Sciences Ltd., Huntingdon, Cambridgeshire, Inglaterra, febrero 2004 y enmienda
febrero 2006; D.W. Coombs, “HFC-22 Un Estudio de Evaluación para Investigar el Potencial de la Sensibilización Cardiaca en los Perros Beagle,” Huntingdon Life Sciences Ltd., Huntingdon, Cambridgeshire, Inglaterra, Agosto 2005; y otros estudios de toxicidad.
d R-507, R-508, y R-509 son designaciones alternativas permitidas para R-507A, R-508A, y R-509A debido cambio en designaciones después de la asignación de R-500 hasta R-509. Los cambios correspondientes no fueron hechos para R-500 hasta R-506.
h En lugares con alturas mayores de 4920 ft (1500 m), el ODL y RCL será 69,100 ppm.
j
En lugares con alturas mayores de 3300 ft (1000 m) pero bajo o igual a 4920 ft (1500 m), el ODL y RCL será 112,000 ppm, y en alturas mayores de 4920 ft (1500 m), el ODL y RCL será 69,100 ppm.
c
507A
R-125/143a (50.0/50.0)
R-32/125/134a (23.0/25.0/52.0)
410Aj
d,j
R-125/143a/134a (44.0/52.0/4.0)
407Ch
Composición (Masa %)
404Aj
Número de
Refrigerante
Tabla 10.2 Clasificaciones de Seguridad y Datos para Mezclas de Refrigerante [Std 34-2010, Tbl 2, Abreviado]
Seguridad de Refrigerantes
10.fm Page 236 Thursday, March 3, 2016 12:48 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
236
10.fm Page 237 Thursday, March 3, 2016 12:48 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Norma 15-2010 de ASHRAE, Norma de Seguridad para Sistemas de
Refrigeración
(Ver norma completa para guía detallada)
7. RESTRICCIONES EN EL USO DE REFRIGERANTE
7.1 General. Las clasificaciones de ocupación, sistema de refrigeración y seguridad de refrigerante citadas en esta sección. Serán determinadas de acuerdo con las Secciones 4, 5 y 6 respectivamente.
7.2 Límites de Concentración del Refrigerante. La concentración de refrigerante en una
descarga completa de cada circuito independiente de sistemas de alta probabilidad no deben
exceder las cantidades mostradas en la Tabla 1 ó 2 de la Norma 341 de ASHRAE excepto según lo
previsto en las Secciones 7.2.1 y 7.2.2 de esta norma. El volumen de espacio ocupado será determinado de acuerdo con la Sección 7.3.
Excepciones:
a. Equipo listado que contiene no más de 6.6 lb (3 kg) de refrigerante, independientemente de su
clasificación de seguridad del refrigerante, está exento de la Sección 7.2 siempre que el equipo
esté instalado de acuerdo con el listado y con las instrucciones de instalación del fabricante.
b. El equipo listado para uso en laboratorios con más de 100 pie2 (9.3 m2) de espacio por
persona, independientemente de la clasificación de seguridad del refrigerante, está exento
de la Sección 7.2 siempre que el equipo esté instalado de acuerdo con el listado y las
instrucciones de instalación del fabricante.
Seguridad de Refrigerantes
237
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
7.2.1 Ocupaciones Institucionales. Las cantidades mostradas en la Tabla 1 ó 2 de la
Noma 341 de ASHRAE serán reducidas al 50% para todas las áreas de ocupaciones institucionales. Además, el total de todos los refrigerantes del Grupo A2, B2, A3 y B3 no deben exceder 550
lb (250 kg) en las áreas ocupadas y salas de máquinas de las ocupaciones institucionales.
7.2.2 Ocupaciones Industriales y Cámaras Frigoríficas. La Sección 7.2 no aplica en ocupaciones industriales y cámaras frigoríficas donde las siguientes siete condiciones serán cumplidas:
1. El espacio (s) que contiene la maquinaria es (son) separada de las otras ocupaciones por la
construcción apretada con puertas herméticas.
2. El acceso está restringido a personal autorizado.
3. El área del piso por ocupante no es menos de 100 pie2 (9.3 m2)
Excepción: El área mínima del piso no aplicará donde el espacio está dotado con salida
directamente al exterior o en salidas de la construcción aprobadas.
4. Detectores de refrigerante están instalados con ubicación de detección y nivel de alarma como
es requerido en las salas de maquinarias de refrigeración de acuerdo con la Sección 8.11.21.1.
5. Llamas abiertas y superficies que excedan 800°F (426,7°C) no son permitidas donde
cualquier grupo de refrigerante A2, B2, A3 o B3 aparte de R-717 (amoniaco) es utilizado.
6. Todos los equipos eléctricos se ajustan a la Clase 1, División 2 de NFPA 705 donde la cantidad de cualquier Grupo A2, B3, A3 o B3 refrigerante aparte de R-717 (amoniaco) en un
circuito independiente excedería 25% del límite de inflamabilidad más bajo (LFL) tras la
liberación al espacio basado en el volumen determinado por la Sección 7.3.
7. Todas las partes que contienen refrigerante en sistemas que excedan 100 hp (74.6 kW)
potencia de excitación del compresor, excepto evaporadores utilizados para refrigeración
o deshumidificación, condensadores utilizados para calefacción, control y presión de las
válvulas de desahogo para cualquiera, y tubería de conexión, están situadas en una sala de
maquinaria o exteriores.
7.3 Cálculos de Volumen. El volumen utilizado para convertir de límites de concentración
del refrigerante a límites de cantidad del sistema de refrigeración para refrigerantes en la Sección
7.2 estarán basadas en el volumen de espacio al cual el refrigerante dispersa en el caso de una fuga
de refrigerante.
7.3.1 Espacios no Conectados. Donde un sistema de refrigeración o una parte del mismo está
situado en una o más espacios ocupados cubiertos que no conectan a través de aberturas permanentes o
ductos HVAC, el volumen del espacio más pequeño ocupado será utilizado para determinar el límite de
la cantidad de refrigerante en el sistema. Donde diferentes pisos y niveles de piso se conectan a través
de un atrio abierto o arreglo de entrepiso, el volumen a ser utilizado en calcular el límite de la cantidad
de refrigerante será determinado multiplicando el área del piso del espacio más bajo por 8.2 pie (2.5 m).
7.3.2 Espacios Ventilados. Donde un sistema de refrigeración o un parte del mismo está situado entre un transportador de aire, en un sistema de ducto de distribución de aire, o en un espacio
ocupado servido por un sistema de ventilación mecánica, todo el sistema de distribución de aire
debe ser analizado para determinar el peor caso de distribución de refrigerante fugado. El peor
caso o el volumen más pequeño en el cual el refrigerante fugado se dispersa deberá utilizarse para
determinar el límite de cantidad de refrigerante en el sistema, sujeto al siguiente criterio.
10.fm Page 238 Thursday, March 3, 2016 12:48 PM
Seguridad de Refrigerantes
Máximo lb (kg) para Varias Ocupaciones
Pública/Mercantil
Residencial Comercial
Grande
Amoniaco Sellado/Sistema de Absorción de Agua
Corredores o vestíbulos en público
0 (0)
0 (0)
3.3 (1.5)
3.3 (1.5)
En lugares adyacentes al aire libre
0 (0)
0 (0)
22 (10)
22 (10)
En otros lugares públicos que no sea
0 (0)
6.6 (3)
6.6 (3)
22 (10)
corredores o vestíbulos
Tipo de Sistema de Refrigeración
Sistemas de Unidades
En otros lugares públicos que no sea
corredores o vestíbulos
Institucional
0 (0)
0 (0)
6.6 (3)
22 (10)
238
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tabla 1 Límites de Cantidad Especial para Absorción de Amoniaco/Agua Sellada y
Sistemas Autónomos
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
7.3.2.1 Cierres. Cierres en el sistema de distribución de aire debe ser considerado. Si uno o
más espacios de los muchos arreglados en paralelo pueden ser cerrados de la fuente de la fuga de
refrigerante, el volumen (es) no debe ser utilizado en el cálculo.
Excepciones:
a. Amortiguadores de humo, compuertas cortafuego y combinación de amortiguadores humo/
fuego que se cierran solo en una emergencia no asociada como una fuga de refrigerante; y
b. Amortiguadores, como cajas de volumen de aire variable (VAV), que dan cierre limitado
donde el flujo de aire no es reducido por debajo del 10% de su máximo (con el ventilador
funcionando).
7.3.2.2 Plenos. El espacio por encima de un techo suspendido no debe ser no debe ser incluido al calcula el límite de la cantidad de refrigerante en el sistema a no ser que tal espacio es parte
del suministro de aire o sistema de retorno.
7.3.2.3 Ductos de Retorno y Suministro. El volumen de los ductos de retorno y suministro y
plenos deben ser incluidos cuando se calcule el límite de cantidad de refrigerante en el sistema.
7.4 Ubicación en una Sala de Máquinas o al Aire Libre. Todos los componentes que contienen refrigerante deben estar ubicados en una sala de máquina o al aire libre, donde
a. la cantidad de refrigerante necesitada excede los límites definidos por la Sección 7.2 y
Sección 7.3, o
b. equipos de absorción de fuego directo, distintos de los sistemas de absorción sellados que
no excedan los límites de cantidad de refrigerante indicado en la Tabla 1 de esta norma, es
utilizado.
7.4.1 Refrigerantes No Inflamables. Las salas de maquinaria requeridas por la Sección 7.4
serán construidas de acuerdo con la Sección 8.11 para refrigerantes de Grupo A1 y B1.
7.4.2 Refrigerantes Inflamables. Las salas de maquinaria requeridas por la Sección 7.4 serán
construidas de acuerdo con las Secciones 8.11 y 8.12 para refrigerantes del Grupo A2, B2, A3 y B3.
7.5 Restricciones Adicionales
7.5.1 Todas las Ocupaciones. Las Secciones 7.5.1.1 hasta 7.5.1.8 aplican a todas las ocupaciones.
7.5.1.1 Refrigerantes Inflamables. El total de todos los Grupos A2, B2, A3 y B3 refrigerantes aparte de R-717 (amoniaco) no debe exceder 1100 lb (500 kg) sin aprobación de AHJ.
7.5.1.2 Pasillos y Vestíbulos. Los sistemas de refrigeración instalados en un pasillo o
vestíbulo público debe ser limitado a cualquiera
a. sistemas de unidades que contienen no más que las cantidades de refrigerante del Grupo
A1 o B1 indicado en la Tabla 1 ó 2 de la Norma 34 de ASHRAE o
b. absorción sellada y sistemas de unidades que tienen cantidades de refrigerante menos que
o igual a aquellos indicados en la Tabla 1 de esta norma.
7.5.1.3 Tipo de Refrigerante y Pureza. Los refrigerantes deben ser de un tipo especificado
por el fabricante del equipo a menos que esté convertida de acuerdo con la Sección 7.5.1.8 Refrigerantes utilizado en equipo nuevo se ajustará a ARI 7003 en pureza a no ser de otra manera especificada por el fabricante del equipo.
7.5.1.4 Refrigerantes Recuperados. Los refrigerantes recuperados no deben ser reutilizados
excepto en el sistema de donde fueron removidos o como indicado en las Secciones 7.5.1.5 ó
7.5.1.6. Cuando la contaminación es evidente por descoloramiento, olor, resultados de la prueba
de ácido o historia del sistema, los refrigerantes recuperados deben ser reclamados de acuerdo con
la Sección 7.5.1.6 antes de la reutilización.
10.fm Page 239 Thursday, March 3, 2016 12:48 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
7.5.1.5 Refrigerantes Reciclados. Los refrigerantes reciclados no deben ser reutilizados
excepto en sistemas que utilizan la misma designación de lubricante y refrigerante y que pertenecen al mismo propietario de cuyo sistema fueron removidos. Cuando la contaminación es evidente por descoloramiento, olor, resultados de prueba de ácidos o historia del sistema,
refrigerantes reciclados serán reclamados de acuerdo con la Sección 7.5.1.6.
Excepciones: Adición de un segundo refrigerante para poder utilizar refrigerantes reciclados, es
utilizado como un absorbente o es un aditivo deliberado.
7.5.1.6 Refrigerantes Reclamados. Refrigerantes usados no deben ser reutilizados en un
equipo diferente del propietario, a no ser que sean probados y encontrado que reúnen los requisitos de AHRI 7003. Refrigerantes contaminados no deben ser utilizados a menos que sean reclamados y encontrado que reúnen los requisitos de AHRI 700.
7.5.1.7 Mezcla. Los refrigerantes incluyendo mezclas de refrigerantes, con diferentes designaciones en la Norma 341 de ASHRAE no se mezclaran en un sistema.
Excepciones: La adición de un segundo refrigerante es permitido donde es especificado por el
fabricante del equipo para mejorar el retorno del aceite a temperaturas bajas. El refrigerante y la
cantidad agregada deben seguir las instrucciones del fabricante.
7.5.1.8 Refrigerante o Conversión de Lubricante. El tipo del refrigerante o lubricante en un
sistema no debe ser cambiado sin evaluación para idoneidad, notificación a AHJ y el usuario,
observación debida de los requisitos de seguridad y reemplazo o aumento de signos e identificación como es requerido en la Sección 11.2.3
7.5.2 Aplicaciones para Confort Humano. Refrigerantes del Grupo A2, A3, B1, B2 y B3 no
deben utilizarse en sistemas de alta probabilidad para confort humano
Excepciones:
a. Esta restricción no aplica a absorción sellada y unidades del sistema que tienen cantidades
de refrigerante menores que o igual a aquellas indicadas en la Tabla 1 de esta norma.
b. Esta restricción no aplica a ocupaciones industriales.
7.5.3 Refrigerantes de Alta Inflamabilidad. Refrigerantes del Grupo A3 y B3 no deben ser
utilizados excepto donde están aprobados por el AHU.
Excepciones:
a. Esta restricción no aplica a laboratorios con más de 100 pie2 (9.3 m2) de espacio por persona.
b. Esta restricción no aplica a ocupaciones industriales.
c. Esta restricción no aplica a sistemas de unidades portátiles enumeradas que contienen no
más de 0.331 lb (150 g) del Grupo A3 de refrigerante, siempre que el equipo esté instalado de conformidad con el listado y las instrucciones de instalación del fabricante.
239
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Seguridad de Refrigerantes
8.1 Fundaciones. Las fundaciones y soportes para unidades de condensado o unidades del
compresor será de construcción incombustible y capaz de soportar cargas impuestas por tales unidades. Materiales de aislamiento como caucho son permisibles entre la fundación y unidades de
condensado o compresor.
8.2 Guardas. Maquinaria en movimiento será guardada de acuerdo con las normas de seguridad aprobadas.4
8.3 Acceso Seguro. Una entrada clara y sin obstáculos y espacio será proporcionado para
inspección, servicio y parada de emergencia de las unidades de condensado, unidades del compresor, condensadores, válvulas de cierre y otros componentes útiles de maquinaria de refrigeración.
Escaleras permanentes, plataformas o equipo de acceso portátil serán suministradas de acuerdo
con los requisitos de AHJ.
8.4 Conexiones de Agua. Suministro de agua y conexiones de descarga serán hechas de acuerdo con los requisitos de AHJ.
8.5 Seguridad Eléctrica. El equipo eléctrico y cableado será instalado de acuerdo con el
Código Eléctrico Nacional5 y los requisitos de AHJ.
8.6 Equipo de Gas Combustible. Dispositivos de gas combustible y equipo utilizado con
sistemas de refrigeración será instalado de acuerdo con las normas de seguridad aprobadas y los
requisitos de AHJ.
8.7 Instalación de Conducto de Aire. Sistemas de conductos de aire de equipo de aire
acondicionado para confort humano que utilizan refrigeración mecánica deben ser instalados de
acuerdo con las normas de seguridad aprobadas, los requisitos de AHJ y los requisitos de la Sección 8.11.7.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
8. RESTRICCIONES DE INSTALACION
240
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
8.8 Partes Refrigerantes en Conducto de Aire. Uniones y todas las partes refrigerantes de
un sistema de refrigeración situados en un conducto de aire que lleva aire acondicionado hacia y
desde un espacio ocupado será construido para soportar una temperatura de 700°F (371.1°C) sin
fugas en la corriente de aire.
8.9 Inspección de Unión de Tubo del Refrigerante. Las uniones de tubo del refrigerante erigidas en las instalaciones deben ser expuestas para inspección visual antes de ser cubiertos o encerrados.
8.10 Ubicación de Tubería del Refrigerante
8.10.1 La tubería del refrigerante que cruza un espacio abierto que proporciona pasadizos en
cualquier edificio no debe ser menor de 7.25 pie (2.2 m) sobre el piso a menos que la tubería está
ubicada contra el techo de tal espacio y es permitido por AHJ.
8.10.2 Los pasadizos no deben estar obstruidos por la tubería del refrigerante. La tubería del
refrigerante no debe ser ubicada en ningún elevador, montaplatos u otro eje que contiene un objeto
en movimiento o en cualquier eje que tiene aberturas a las viviendas o medios de salida. La
tubería del refrigerante no debe ser instalada en una escalera pública cerrada, rellano de la escalera
o medios de salida.
8.10.3 La tubería del refrigerante no debe penetrar pisos, techos o tejados.
Excepciones:
a. Penetraciones que conectan el sótano y el primer piso.
b. Penetraciones que conectan el piso alto y una maquinaria y una maquinaria del ático o
instalación en el tejado.
c. Penetraciones que conectan pisos adyacentes servidos por el sistema de refrigeración.
d. Penetraciones de un sistema directo donde la concentración del refrigerante no supera lo
enumerado en la Tabla 1 ó 2 de la Norma 341 de ASHRAE para el espacio ocupado más
pequeño a través del cual la tubería de refrigerante atraviesa.
e. En otra de las ocupaciones industriales y donde la concentración del refrigerante excede
lo enumerado en la Tabla 1 ó 2 de la Norma 34 de ASHRAE para los espacios ocupados
más pequeños, las penetraciones que conectan piezas separadas de equipos que son
1. Cerrada por un gas hermético aprobado, ducto resistente al fuego o eje con aberturas a
aquellos pisos servidos por el sistema de refrigeración o
2. Ubicadas en la pared exterior de un edificio cuando está ventilado al exterior o al
espacio servido por el sistema y no utilizado como un pozo de ventilación, patio cerrado o espacio similar.
8.10.4 Tubería del refrigerante instalada en pisos de concreto deben ser encajonada en ductos
de tubos. La Tubería del refrigerante debe ser apropiadamente aislada y apoyada para prevenir
daños por vibraciones perjudiciales, estrés o corrosión.
8.11 Sala de Maquinaria de Refrigeración, Requisitos Generales. Cuando el sistema de
refrigeración está ubicado en el interior y una sala de maquinaria es requerida por la Sección 7.4,
la sala de maquinaria se hará de conformidad con las disposiciones siguientes.
8.11.1 Las salas de maquinarias no están prohibidas de albergar otro equipo mecánico a menos
que esté específicamente prohibido en alguna parte en esta norma. Una sala de maquinaria debe estar
dimensionada para que las partes sean accesibles con espacio para servicio, mantenimiento y operaciones. Habrá un espacio claro no menor de 7.25 pie (2.2 m) bajo el equipo situado sobre los pasadizos.
8.11.2 Cada sala de maquinaria de refrigeración tendrá una puerta hermética o puertas con apertura hacia el exterior, de cierre automático si se abren en el edificio y adecuadas en número para asegurar la libertad para las personas de escapar en una emergencia. Con la excepción de las puertas de
acceso y paneles en los ductos de aire y unidades de manejo de aire conforme a la Sección 8.11.7, no
habrá aberturas que permitan el paso de escape de refrigerante a otras partes del edificio.
8.11.2.1 Cada sala de maquinaria de refrigeración debe contener un detector, ubicado en un
área donde el refrigerante de una fuga se concentrará, que actúe una alarma y ventilación
mecánica de acuerdo con la Sección 8.11.4 a un valor no mayor que el correspondiente TLV-TWA
(o medida de toxicidad compatible con éste). La alarma anunciará alarmas audibles y visibles dentro de la sala de maquinaria de refrigeración y fuera de cada entrada a la sala de maquinaria de
refrigeración. Las alarmas requeridas en esta sección serán de tipo de ajuste manual con el reajuste ubicado dentro de la sala de maquinaria de refrigeración.
Las alarmas fijadas en otros niveles (como IDLH) y alarmas de reajuste automático son permitidas además de aquellas requeridas por esta sección. El significado de cada alarma debe estar
claramente marcado por señalización cerca de los anunciadores.
Excepciones:
a. Para amoniaco, referir a la Sección 8.12 (h).
b. Detectores no son necesarios cuando los sistemas que sólo utilizan R-7187 (agua) están
ubicados en la sala de maquinaria de refrigeración.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Seguridad de Refrigerantes
10.fm Page 240 Thursday, March 3, 2016 12:48 PM
10.fm Page 241 Thursday, March 3, 2016 12:48 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
8.11.3 Las salas de maquinaria serán ventilados al exterior, utilizando ventilación mecánica
de acuerdo con las Secciones 8.11.4 y 8.11.5.
8.11.4 La ventilación mecánica referida en la Sección 8.11.3 se hará por uno o más ventiladores
motorizados capaces de extraer aire de la sala de máquinas por lo menos en la cantidad dada en la fórmula en la Sección 8.11.5. Para obtener un reducido flujo de aire para ventilación normal, varios ventiladores o ventiladores de varias velocidades serán utilizados. Provisiones deben hacerse para el aire
interior para reemplazar el que está siendo evacuado. Aperturas para el aire de entrada serán situadas
para evitar recirculación. El suministro de aire y ductos de escape en la sala de maquinaria no servirán
para otra área. La descarga del aire será a los exteriores de tal manera de no causar molestia o daño.
8.11.5 La ventilación mecánica requerida para evacuar una acumulación de refrigerante
debido a fugas o rupturas del sistema será capaz de remover aire de la sala de maquinaria en no
menos de la siguiente cantidad:
donde
Q
=
G
=
Q = 100 x G0.5
(I-P)
Q = 70 x G0.5
(SI)
corriente de aire
masa de refrigerante en el sistema más grande, cualquier parte de la cual está situada en la sala de maquinarias, lb (kg)
Una parte de la ventilación mecánica de la sala de maquinaria de refrigeración será
a. Operada, cuando está ocupada, para suministrar por lo menos 0.5 cfm/pie2 (2.54 K/s/m2)
del área de la sala de maquinaria ó 20 cfm (9.44 L/s) por persona y
b. Operable, cuando está ocupada a un volumen requerido de no exceder lo más alto de una
elevación de temperatura de 18°F (10°C) sobre la temperatura de aire de entrada o una
temperatura máxima de 122°F (50°C)
Cuando un sistema de refrigeración está ubicado en el exterior más de 20 pie (6.1 m) de las
aperturas del edificio y está encerrada por un ático, cobertizo u otra estructura abierta, ventilación
natural o mecánica será provista. Los requisitos para tal ventilación natural son como sigue:
a. La sección transversal de abertura libre para la ventilación de una sala de maquinaria será
por lo menos
F = G0.5
(I-P)
F = 0.138 G0.5
(SI)
241
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Seguridad de Refrigerantes
8.11.7 No habrá corriente de aire hacia o desde un espacio ocupado a través de una sala de
maquinaria a menos que el aire es conducido y sellado de tal manera para prevenir cualquier fuga
de refrigerante de entrar a la corriente de aire. Puertas de acceso y paneles en las unidades de conductos y tratamiento de aire serán empaquetadas y ajustadas.
8.11.8 Acceso. El acceso a la sala de maquinaria de refrigeración será restringido a personal
autorizado. Las puertas serán claramente marcadas o signos permanentes serán publicados en
cada entrada para indicar esta restricción.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
donde
F = el área de abertura libre, pie2 (m2)
G = la masa de refrigerante en el sistema más grande, cualquier parte de la cual está
situada en la sala de maquinaria, lb (kg)
b. Las ubicaciones de las aberturas de ventilación por gravedad estarán basadas en la densidad relativa del refrigerante al aire.
8.11.6 Llamas no abiertas que usan aire de combustión de la sala de maquinaria serán instaladas
donde cualquier refrigerante es utilizado. El equipo de combustión no deberá instalarse en la misma
sala de maquinaria con equipo que contiene refrigerante excepto bajo una de las condiciones siguientes:
a. el aire de combustión es conducido desde fuera de la sala de maquinaria y sellado de tal
manera para prevenir cualquier fuga de refrigerante de entrar en la cámara de combustión o
b. un detector de refrigerante, conforme a la Sección 8.11.2.1, es empleado para cerrar
automáticamente el proceso de combustión en el evento de fuga de refrigerante.
Excepciones:
a. Salas de maquinarias donde solamente el dióxido de carbono (R-744) o agua (R-718) es
el refrigerante.
b. Salas de maquinarias donde solamente amoniaco (R-717) es el refrigerante y motores de
combustión interna son utilizados como la fuerza motriz para los compresores.
10.fm Page 242 Thursday, March 3, 2016 12:48 PM
Seguridad de Refrigerantes
9.7.8 Para sistemas en los cuales una o más de las siguientes condiciones aplica, dispositivos
de alivio de presión y tapones fusible descargarán a la atmósfera en una ubicación no menor de
1.5 pie (4.57 m) sobre el nivel del suelo colindante y no menor de 20 pie (6.1 m) de cualquier ventana, aberturas de ventilación o salida en cualquier edificio.
a. Cualquier sistema que contiene un refrigerante Grupo A3 o B3.
b. Cualquier sistema que contiene más de 6.6 lb (3 kg) de un refrigerante Grupo A2, B1 o B2.
c. Cualquier sistema que contiene más de 110 lb (50 kg) de un refrigerante Grupo A1.
d. Cualquier sistema para el cual una sala de maquinaria es requerida por las disposiciones
de la Sección 7.4.
La descarga será terminada en una manera que evitará ambos el refrigerante descargado de
ser rociado directamente sobre el personal en la vecindad y material extraño o escombros de entrar
en la tubería de descarga. La tubería de descarga conectada al lado de la descarga de un tapón de
fusible o miembro de ruptura debe tener dispositivos para evitar conectar la tubería en el caso de
que el tapón de fusible o miembro de ruptura funcione.
Excepciones: Cuando R-718 (agua) es el único refrigerante, descarga a un drenaje de piso es también aceptable si todas de las siguientes tres condiciones son cumplidas:
242
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
9. DISEÑO Y CONSTRUCCION DE EQUIPOS Y SISTEMAS
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
8.12 Sala de Maquinaria, Requisitos Especiales. En casos especificados en las reglas de la
Sección 7.4, una sala de maquinaria de refrigeración debe reunir los siguientes requisitos especiales además de los de la Sección 8.11:
a. No habrá dispositivo generador de llama o superficie caliente operando continuamente
sobre 800°F (427°C) permanentemente instalado en la sala.
b. Las puertas que comunican con el edificio serán aprobadas, cerradura automática, puertas
contra incendios herméticas.
c. Paredes, piso y techo será ajustados y de construcción no combustible. Paredes, piso y
techo que separan la sala de maquinaria de refrigeración de otros espacios ocupados serán
de por lo menos de una hora de construcción resistente al fuego.
d. La sala de maquinaria de refrigeración tendrá una puerta que abra directamente a los exteriores o a través de un vestíbulo equipado con cerradura automática, puertas muy ajustadas.
e. Aberturas exteriores, si están presentes, no estarán bajo ningún escape contra incendio o
ninguna escalera abierta.
f. Todas las tuberías que atraviesen las paredes interiores, techo o piso de tales salas estarán
fuertemente selladas a las paredes, techo o piso a través de los cuales pasan.
g. Cuando los Grupos refrigerantes A2, A3, B2 y B3 son utilizados, la sala de maquinaria se
ajustará a la Clase 1, División 2, del Código Eléctrico Nacional.5 Cuando los Grupos
refrigerantes A1 y B1 son utilizados, la sala de maquinaria no necesita cumplir con la
Clase 1, División 2 del Código Eléctrico Nacional.
Excepciones: Cuando amoniaco es utilizado, los requisitos de la Clase 1, División 2 del
Código Eléctrico Nacional no aplicará siempre que los requisitos de la Sección 8,12(h)
son cumplidos.
h. Cuando amoniaco (R-717) es utilizado, la sala de maquinaria no requiere cumplir con la
Case 1, División 3 del Código Eléctrico Nacional,5 siempre que (1) el sistema de ventilación
mecánica en la sala de maquinaria es rodado continuamente y fallas del sistema de ventilación mecánica acciona una alarma ó (2) la sala de maquinaria es equipada con un detector,
conforme a la Sección 8.11.2.1, excepto que el detector deberá alarmar a 1000 ppm.
i. Control remoto del equipo mecánico en la sala de la maquinaria de refrigeración debe ser
suministrada inmediatamente fuera de la puerta de la sala de maquinaria únicamente para
el propósito de apagar el equipo en una emergencia. Los ventiladores estarán en un circuito eléctrico separado y tendrán un interruptor de control situado inmediatamente fuera
de la puerta de la sala de maquinaria.
8.13 Descarga de Emergencia Manual del Refrigerante Amoniaco. Cuando sea requerido
por AHJ, la descarga de emergencia manual o arreglos de difusión para refrigerantes amoniaco
deben ser suministrados.
8.14 Descarga de Purga. La descarga de los sistemas de purga deben ser gobernados por las
mismas reglas como dispositivos de alivio de presión y tapones fusible (ver Sección 9.7.8) y serán
canalizados en conjunto con estos dispositivos.
Excepciones: Cuando R-718 (agua) es el refrigerante.
10.fm Page 243 Thursday, March 3, 2016 12:48 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
1. La presión de ajuste del dispositivo de alivio de presión no exceda 15 psig.
2. El drenaje de piso está dimensionado para manejar no menos que el caudal de un tubo
simple roto en cualquier intercambiador de calor que contiene refrigerante, y
3. Cualquiera:
a. El AHJ encuentra aceptable que el fluido de trabajo, inhibidor de corrosión y otros
aditivos utilizados en este tipo del sistema de refrigeración puede frecuentemente ser
descargado al sistema de alcantarillado, o
b. Un tanque de captura, dimensionado para manejar la descarga esperada, está instalado
y equipado con una válvula de drenaje cerrada normalmente y una línea de rebose
para drenaje.
9.7.8.1 La aplicación de las válvulas de alivio de presión que descargan de un recipiente de
presión superior a un recipiente de presión inferior del sistema deberá cumplir con (a) hasta (c)
como sigue:
a. La válvula de alivio de presión que protege el recipiente de presión superior será seleccionado para entregar capacidad de acuerdo con la Sección 9.7.5 sin exceder la presión de
trabajo permisible máxima del recipiente de presión superior dando cuenta por el cambio
en masa de la capacidad de flujo debido a la contra presión elevada.
b. La capacidad de la válvula de alivio de presión que protege la parte del sistema que recibe una
descarga de una válvula de alivio de presión que protege un recipiente de presión superior
debe ser por lo menos la suma de la capacidad requerida en la Sección 9.7.5 más la masa de
capacidad de flujo de la válvula de alivio de presión descargando en esa parte del sistema.
c. La presión de diseño del cuerpo de la válvula de alivio utilizado en el recipiente de
presión superior debe ser tasado para operación en la presión de diseño del recipiente de
presión superior en ambas áreas que contienen presión de la válvula.
9.7.8.2 Descarga de Amoniaco. El amoniaco de las válvulas de alivio de presión será descargado en uno o más de lo siguiente:
a. La atmósfera, de acuerdo a la Sección 9.7.8.
b. Un tanque que contiene un alón de gua por cada libra de amoniaco (8.3 litros de agua por
cada kilogramo de amoniaco) que será liberado en una hora del dispositivo de alivio superior conectado a la tubería de descarga. El agua será impedida de congelación. La tubería
de descarga del dispositivo de alivio de presión distribuirá el amoniaco en el fondo del
tanque pero no inferior a 3.3 pie (10 m) bajo el máximo nivel del líquido. El tanque contendrá el volumen de agua y amoniaco sin desbordar.
c. Otros sistemas de tratamientos que reúnan los requisitos de AHJ.
Seguridad de Refrigerantes
243
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
9.7.8.3 Descarga Opcional de Dióxido de Azufre. Cuando el dióxido de azufre es utilizado, la
descarga será en el tanque de solución absorbente que será utilizado para ningún otro propósito excepto
la absorción del dióxido de azufre. La solución absorbente será un galón de solución de dicromato
estándar (2.5 libras de dicromato de sodio por galón de agua) (300 gramos de de dicromato de sodio
por litro de agua) ´por cada libro de dióxido de azufre en el sistema (8.3 litros de solución de dicromato
estándar por cada kilogramo de dióxido de azufre en el sistema). Las soluciones hechas con sosa
caústica o ceniza de sosa utilizados en lugar de dicromato de sodio a menos que la cantidad y fuerza
tiene el equivalente a la potencia de dióxido de azufre absorbente. El tanque será construido de no
menos de 1/8 de pulg. (3.2 m) o acero o hierro calibre No. 11 US. El tanque tendrá una tapa abatible o,
si es del tipo cerrado, tendrá un orificio de respiración en la parte superior. Todas las conexiones de la
tubería serán a través de la parte superior del tanque solamente. La tubería de descarga de la válvula de
alivio de presión descargará el dióxido de azufre en el centro del tanque cerca del fondo.
9.7.8.4 El tamaño de la tubería de descarga de un dispositivo de alivio de presión o tapón de
fusible no será menos que el tamaño de salida del dispositivo de alivio de presión o tapón de fusible. Donde las salidas de dos o más dispositivos de alivio o tapones de fusible están conectadas a
una línea común o encabezamiento, el efecto de contrapresión que se desarrollará cuando más de
un dispositivo de alivio o tapón de fusible opera será considerado. El tamaño del encabezamiento
de descarga común aguas abajo para cada uno de los dos o más dispositivos de alivio o tapones de
fusible que se espera que operen simultáneamente estará basado en la suma de las zonas de salida
con debida tolerancia para la caída de presión en todas la secciones corriente abajo.
La longitud máxima de la tubería de descarga instalada en las salidas de los dispositivos de
alivio de presión y tapones de fusible descargando a la atmósfera será determinada por el método
Apéndice Normativo E. Ver Tabla 3 para la capacidad de flujo de varias longitudes equivalentes
de tubería de descarga para válvulas de alivio convencionales.
11.fm Page 244 Thursday, March 3, 2016 12:48 PM
Carga de Refrigeracion
CARGA DE REFRIGERACION
Carga de Transmisión
El coeficiente total de la transferencia de calor U de la pared, piso o techo de un espacio
refrigerado puede derivarse de:
1
U = --------------------------------------------------------------------------1  f i + x1  k 1 + x2  k 2 + 1  f o
donde
U
x
k
fi
fo
=
=
=
=
=
coeficiente de transferencia de calor total, Btu/h·pie2·°F (W/[m2·K])
espesor de pared, in. (mm)
conductividad térmica del material de pared, Btu·pulg./h·ft2·°F (W/[m2·K])
película interior o conductancia de superfice, Btu/h·pie2·°F (W/[m2·K])
película exterior o conductancia de superficie, Btu/h·pie·°F (W/[m2·K])
1.65 Btu/h·ft2·°F (9.37 W/[m2·K]) para fi y fo es utilizado frecuentemente para aire tranquilo.
Si la superficie externa está expuesta a viento de 15 mph (24 km/h), fo es incrementada a 6 Btu/
h·pie2·°F (34 W/[m2·K]).
Con paredes de gran espesor, la resistencia x/k hace U tan pequeño que l/fp tiene poco efecto
y puede ser omitida del cálculo.
Después de establecer U, la ganancia de calor está dada por la ecuación básica:
q = UAt
donde
q
=
A
=
t
=
fuga de calor, Btu/h (W)
área exterior de la sección, pie2 (m2)
diferencia entre temperatura de aire exterior y temperatura de aire del espacio
refrigerado, °F (°C)
La ganancia de calor latente debido a transmisión de humedad a través de paredes, pisos y
techos debido a instalaciones frigoríficas de construcción moderna es insignificante.
Tabla 11.1 Conductividad Térmica de Aislamiento para Paredes, Pisos y Techo,
Btu·in/h·pie2·°F (W/[m2·K])
Tabla 11.2 Espesor de Aislamiento Mínimo
Temperatura de Almacenamiento
°F (°C)
50 (10)
25 (–4)
–15 (–26)
Tabla 11.3
Tipos de Superficie Típica
Superficies de color oscuro
Superficies de color medio
Superficies de color claro
Espesor de Poliuretano Expandido
in. (mm)
2 (50)
3 (75)
5 (100)
Efecto del Sol
Pared Este
°F (°C)
8 (5)
6 (4)
4 (3)
Pared Sur
°F (°C)
5 (3)
4 (3)
2 (2)
Pared Oeste Tejado Plano
°F (°C)
°F (°C)
8 (5)
20 (11)
6 (4)
15 (9)
4 (3)
9 (5)
Nota: Agregar °F (°C) a la diferencia de temperatura normal para cálculos de fuga de calor para compensar por los
efectos del sol—no utilizar para diseño de aire acondicionado.
244
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Poliuretano
Poliuretano
Poliestireno Fibra de Vidrio y Poliestireno
Vidrio Celular
(Expandido)
(Tablero)
(Extrusionado)
(Perlas Moldeadas)
k = 0.16 (0.023) k = 0.18 (0.026) k = 0.20 (0.029)
k = 0.33 (0.036)
k = 0.28 (0.048)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
11.
11.fm Page 245 Thursday, March 3, 2016 12:48 PM
Q1 = mc1(t1 – t2)
2. Eliminación de calor para congelar el producto.
Q2 = mhif
3. Eliminación de calor en enfriamiento desde el punto de congelación a la temperatura final
bajo el punto de congelamiento:
Q3 = mc2 (tf – t2)
donde
Q1, Q2, Q3, Q4 = eliminación de calor, Btu (kJ)
m
= peso del producto, lb (kg)
c1
= calor específico del producto por encima de congelación, Btu/lb·°F
(kJ/[kg·K])
= temperatura inicial del producto por encima de congelación, °F (°C)
t1
= temperatura inferior del producto por encima de congelación, °F (°C)
t2
tf
= temperatura de congelación del producto, °F (°C)
hif
= calor latente de fusión del producto, Btu/lb (kJ/kg)
c2
= calor específico del producto debajo de congelación, Btu/lb·°F
(kJ/[kg·K])
= temperatura final del producto debajo de congelación, °F (°C)
t3
Calores específicos encima y debajo de congelación para muchos productos están dados en la
Tabla 3 del Capítulo 19 en el Manual de Refrigeración 2010 de ASHRAE.
La capacidad del sistema de refrigeración para productos traídos a espacios refrigerados está
determinada por el tiempo asignado para eliminación de calor y se asume que el producto está
adecuadamente expuesto para eliminar el calor en ese tiempo. El cálculo es:
Q1 + Q2 + Q3
q = --------------------------------n
carga de enfriamiento del producto, Btu/h (kW)
período de tiempo asignado, h
Un calor latente del producto de fusión está relacionado a su contenido de agua y puede ser
estimado multiplicando el porcentaje de agua del producto (expresado como un decimal) por el
calor latente del agua de fusión, 144 Btu/lb (334 kJ/kg). La mayoría de los productos congelados
en el intervalo de 26 a 31°F (–3 a –0.5°C). Cuando la temperatura de congelación exacta no es
conocida, asuma que esta es 28°F (–2.2°C).
245
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
donde
q
=
n
=
Carga de Refrigeracion
1. Eliminación de calor en enfriamiento desde la temperatura inicial hasta un punto de congelación del producto:
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Carga de Producto
11.fm Page 246 Thursday, March 3, 2016 12:48 PM
Carga de Refrigeracion
Tabla 11.4 Equivalente de Calor de Motores Eléctricos
Pérdidas del Motor en Carga Conectada en
Espacio Exterior el Exterior de Espacio
Refrigerado
Refrigerado
Btu/hp·h (kW/kW)
Btu/hp·h (kW/kW)
Btu/hp·h (kW/kW)
1/8 a 1/3 (0.1 a 0.4)
4600 (1.8)
2550 (1.0)
2100 (0.8)
1/2 a 3 (0.4 a 2.2)
3800 (1.5)
2550 (1.0)
1300 (0.5)
5 a 20 (2.2 a 15)
3300 (1.3)
2550 (1.0)
800 (0.3)
Equivalencia de Calor Aproximado de Ocupación por Persona
qp = 1295 – 11.5t (272 – 6t)
donde
qp = ganancia de calor por persona, Btu/h (kW)
t
= temperatura del espacio refrigerado, °F (°C)
Motor hp (kW)
Carga Conectada en
Espacio Refrigerado
Carga de Aire de Infiltración
Ganancia de calor a través de puertas de intercambio de aire es:
qt = qDtDf (1 – E)
donde
qt
=
q
=
Dt
Df
E
=
=
=
ganancia de calor promedio para las 24-h u otro período, Btu/h (kW)
carga de refrigeración latente y sensible para carga máxima establecida, Btu/h
(kW)
factor tiempo abierto de puerta
Factor flujo de puerta
eficacia de dispositivo de protección de puerta
q = 3790 WH1.5 (Qs/A)(1/Rs)
W
Rs
=
=
(Qs/A)(1/Rs)
 P p + 60 o 
D t = --------------------------------3600 d
=
=
=
=
=
(SI)
carga de calor sensible de aire de infiltración por pie cuadrado de abertura de
puerta como se lee en la Figura 11.1, ton/ft2 (kW/m2)
ancho de la puerta, ft (m)
relación de calor sensible de la ganancia de calor de aire de infiltración, a partir de
un gráfico sicrométrico.
El factor de tiempo abierto de puerta Dt puede ser calculado como sigue:
donde
Dt
P
p
o
d
(I-P)
parte decimal de tiempo de puerta es abierto
número de pasajes de puerta
tiempo de cierre de puerta abierta, segundos por pasaje
puerta de tiempo simplemente se encuentra abierta, min
el período de tiempo diario (u otro), h
246
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
q = 0.5773790 WH
donde
Qs/A =
1.5
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Carga Interna
11.fm Page 247 Thursday, March 3, 2016 12:48 PM
Carga de Refrigeracion
Ganancia de Calor Sensible por Intercambio de Aire para Puerta Continuamente
Abierta con Flujo Totalmente Establecido [2010R, Ch 24, Fig 5]
247
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 11.1 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 11.1 (I-P) Ganancia de Calor Sensible por Intercambio de Aire para Puerta
Continuamente Abierta con Flujo Totalmente Establecido [2010R, Ch 24, Fig 5]
11.fm Page 248 Thursday, March 3, 2016 12:48 PM
Carga de Refrigeracion
La carga relacionada con equipos consiste esencialmente de carga del ventilador donde la circulación de aire forzado es utilizada, recalentamiento donde el control de humedad es proporcionado, descongelación de ganancia de calor donde la descongelación ocurre y evaporación de la
humedad donde el proceso de descongelación está expuesto a aire refrigerado. Para seleccionar
con precisión el equipo extractor de calor, una distinción será hecha entre esas cargas de calor de
equipo que se sienten entre el espacio refrigerado y aquellos que son introducidos directamente al
fluido refrigerante.
El equipo de ganancia de calor suele ser menor a temperaturas de espacio aproximadamente
por encima de 30°F (–1°C), pero puede ser de hasta 15%.
Factor de Seguridad
Generalmente, un 10% del factor de seguridad es aplicado a la carga calculada para permitir
por posibles discrepancias entre los criterios de diseño y operación actual. La capacidad del
sistema de refrigeración será suficiente para manejar la carga con el tiempo real de operación, permitiendo ciclos de descongelación.
Enfriadores de Aire de Circulación Forzada
El serpentín refrigerante y ventilador accionado por motor son los componentes básicos y
medios de descongelación del serpentín son agregados para operaciones de baja temperatura
donde la congelación del serpentín puede impedir el rendimiento. Los ventiladores de hélice de
accionamiento directo son los más comunes, pero para tiros largos, configuración a través de
extracción es preferida. Para cargas sobre 32°F (0°C),la separación del serpentín es generalmente
6 a 8 fins por pulg- (240 a 320 fins por metro); 32°F (0°C) un máximo de 4 fins por pulg. (160 fins
por metro) es preferido. La distribución uniforme del refrigerante halocarbono es por lo general
alcanzado en serpentines de expansión directa por los distribuidores de refrigerantes. Las unidades en sistemas de refrigeración más grandes son a menudo tipos de recirculación que bombean
líquido con discos de orificio.
Las capacidades de los enfriadores de aire están generalmente basadas en la diferencia de
temperatura entre el aire de entada y el serpentín. Cuanto más alto sea el TD, menor la humedad
relativa del espacio. Entre 8°F (5°C) y 16°F (9°C) TD es habitual, excepto para los productos
envasados y salas de trabajo donde el TD de 25°F (14°C) es común. Unidades de baja temperatura
generalmente tienen el TD bajo 15°F (8°C) para la economía del sistema y limita la frecuencia de
descongelamiento.
El control más frecuente de flujo del refrigerante es una válvula de expansión, más frecuentemente tipo termostático. Las válvulas de expansión eléctrica, que requieren una válvula, controlador y sensor de control también están disponibles.
Sistemas grandes de refrigeración con más frecuencia tienen evaporadores inundados, más a
menudo válvulas de flotador de lado bajo. Las válvulas del refrigerante que abren o cierran el flujo
son generalmente válvulas de solenoide. Flujos más grandes pueden requerir válvulas de solenoide accionadas por piloto. Cuando se decide limitar la carga del motor del compresor durante el
descenso de temperatura, una válvula reguladora de presión del evaporador puede ser utilizada
para limitar la presión de succión del compresor.
248
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Descongelamiento para serpentines y bandejas de drenaje de unidades de temperatura baja
puede ser de gas caliente, eléctrico o agua. Generalmente el descongelamiento es hecho con el
ventilador apagado. El control de descongelación es generalmente por microprocesador, con un
termostato instalado dentro del serpentín. Generalmente una elevación a 45°F (7°C) retorna la
unidad al ciclo de operación. Líneas de desagüe deben estar bien inclinadas, aisladas y atrapadas
fuera del espacio refrigerado.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Carga Relacionada con Equipos
11.fm Page 249 Thursday, March 3, 2016 12:48 PM
Carga de Refrigeracion
249
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 11.3 Enfriador Unitario Tipo Sobrealimentación de Líquido [2010R, Ch 14, Fig 4]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 11.2 Enfriador de Perfil Bajo [2010R. Ch 14, Fig 3]
12.fm Page 250 Thursday, March 3, 2016 2:00 PM
DATOS DE CARGA DE AIRE ACONDICIONADO
Datos de Carga de Aire
Cargas de Enfriamiento
Obtener datos del tiempo apropiado y seleccionar las condiciones de diseño. Además de la
bola seca convencional con coincidente medio de bola húmeda, también considerar el punto de
condensación con coincidente medio de bola seca, particularmente con espacios que requieren
grandes cantidades de aire exterior o control cerrado de humedad. Seleccionar la bola seca interior, bola húmeda y tasa de ventilación, incluyendo variaciones permisibles y límites de control.
Considerar horarios propuestos de ocupación, iluminación y procesos que contribuyen a la carga
interna. Varios momentos diferentes de días y meses deben frecuentemente ser analizados para
determinar el tiempo de carga máxima.
La Norma 183-2007 de ANSI/ASHRAE/ACCA fija los estándares mínimos para cálculos de
carga no residencial.
Actualmente hay dos métodos de ASHRAE para calcular la carga de enfriamiento. El primero es el método de Balance de Calor (HB), cuyas ecuaciones están codificadas en un programa de
computación genérica ligado a un programa de interface del usuario. El código de fuente para
estos programas está en el Juego de Herramientas de Cálculo de Carga de ASHRAE.
El segundo método es el método de Series de Tiempo Radiante (RTS), una simplificación del
método de balance de calor, que aún requieren un programa informático complejo para un edificio
de varias habitaciones
Debido a la variación en los coeficientes de transferencia de calor, precisión de construcción
y manera de la operación actual del edificio, un cálculo de carga de refrigeración nunca puede ser
más que una buena estimación de la carga real.
Para la estimación preliminar de la carga de refrigeración, las cifras aquí son una guía muy
áspera. Los métodos de cálculo de la carga de refrigeración aproximada presentado aquí son útiles
para el diseñador experimentado.
Para el diseño y componentes de tamaño de sistemas de central de aire acondicionado, se
necesita más que la carga de refrigeración. El tipo de sistema, energía del ventilador y ubicación,
ganancia y pérdida de calor directo, fugas de conductos, calor extraído de las luces y tipo de
sistema de retorno todas deben ser consideradas.
Cargas de Calefacción
Métodos Previos de Cálculo de Cargas de Enfriamiento
Los procedimientos descritos en los Capítulos 17 y 18 del Manual de Fundamentos 2013 de
ASHRAE son los más actuales y medios derivados científicamente para estimar la carga de enfriamiento para un espacio definido de un edificio, pero métodos en ediciones anteriores del Manual
de ASHRAE son válidos para muchas aplicaciones. Estos procedimientos anteriores son simplificaciones de los principios del Balance de Calor y su uso requiere experiencia para hacer frente a
circunstancias atípicas o inusuales. En realidad, cualquier estimado de carga de calefacción o
enfriamiento no es mejor que los supuestos utilizados para definir condiciones y parámetros tales
como composición física de las diversas superficies envolventes, condiciones de ocupación y uso
y condiciones del clima ambiente. La experiencia del practicante nunca puede ser ignorada.
La diferencia primaria entre los métodos del Balance de Calor (HB) y las Series de Tiempo
Radiante (RTS) y los viejos métodos es el acercamiento directo de los nuevos métodos, comparados a las simplificaciones necesitadas por la capacidad limitada del ordenador disponible previamente.
El método de función de transferencia (TFM), por ejemplo, necesitó muchos pasos de cálculo. Este fue originalmente diseñado para análisis de energía con énfasis en el uso de energía diario, mensual y anual, y por consiguiente fue más orientado para promediar cargas de refrigeración
por hora que cargas de diseño de pico.
250
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Cálculos similares para cargas de enfriamiento son hechas, pero las temperaturas fuera de los
espacios acondicionados son generalmente menores que las temperaturas de espacio mantenidas.
Ganancias térmicas solares y ganancias térmicas internas no son incluidas y almacenamiento térmico de la estructura de edificios o contenido es generalmente ignorado. Esto es generalmente
suficiente para hacer frente a una situación de peor caso. Hay muy a menudo necesidad para
refrigeración en meses fríos, para espacios perimetrales con ganancias térmicas solares y espacios
interiores con ganancia térmica significante
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
12.
12.fm Page 251 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
251
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
El método diferencia de temperatura total equivalente con un promedio de tiempo
(TETD/TA) ha sido un método altamente seguro (si subjetivo) de estimación de carga desde su
presentación inicial en el Manual de Fundamentos de 1967. Originalmente intencionado como un
método manual de cálculo, demostró adecuado sólo como una aplicación informática debido a la
necesidad de calcular un perfil extendido de valores de ganancia de calor por hora de la que los
componentes radiales tuvieron que ser promediados sobre un tiempo representativo de la masa
general del edificio involucrado. Debido a la percepción de las características de almacenamiento
térmico de un edificio determinado es casi enteramente subjetiva, con poca información específica
para que el usuario juzgue variaciones, el método de diferencia de temperatura total equivalente
con un promedio de tiempo (TETD/TA) la utilidad principal siempre ha sido al ingeniero con
experiencia.
El método diferencial de temperatura de carga de refrigeración con factores de carga de
refrigeración solar (CLTD/CLF) intentó simplificar los métodos de dos pasos TFN y TETD/TA
en una técnica de un solo paso que procedió directamente de datos brutos a carga de enfriamiento
sin conversión intermedia de ganancia de calor radiante a carga de refrigeración. Una serie de factores fueron tomados de los resultados de cálculo de carga de enfriamiento (producidos por métodos más sofisticados) como “diferencias de temperatura de carga de enfriamiento” y “factores de
carga de enfriamiento” para uso en ecuaciones de conducción tradicional (q = UAt). Los resultados son valores de carga de enfriamiento aproximados en vez de valores de ganancia de calor sencillo. Las simplificaciones y suposiciones utilizadas en el trabajo original para derivar aquellos
factores que limitan la aplicabilidad de este método a aquellos tipos de edificios y condiciones
para lo cual los factores CLTD/CLF fueron derivados, el método no debe utilizarse más allá de la
gama de aplicabilidad.
Los procedimientos TFM, TETD/TA Y CLTD/CLF no han sido invalidados o desacreditados.
Ingenieros experimentados los han utilizado exitosamente en millones de edificios alrededor del
mundo. La exactitud de cálculos de carga de refrigeración en la práctica depende principalmente
en la disponibilidad de información exacta y el juicio del ingeniero de diseño en los supuestos utilizados en la interpretación de los datos disponibles. Aquellos factores tienen mayor influencia en
el éxito de un proyecto que lo hacen la elección de un método de cálculo de carga de enfriamiento
especial.
El beneficio principal de cálculos HB y RTS es su dependencia algo reducida en la entrada
puramente subjetiva (ej. la determinación de un período de tiempo promedio adecuado para
TETD/TA, determinando factores de seguridad apropiados para agregar a los resultados redondeados TFM, determinar si los factores CLTD/CLF son aplicables de un aplicación única específica).
Sin embargo, utilizando las técnicas al día en diseño del mundo real todavía requiere juicio en la
parte del ingeniero de diseño y cuidado en elegir suposiciones apropiadas, al igual que en la aplicación de métodos de cálculo antiguos.
5.0†
1.5
3.0†
1.0
40
75
45
100
25
50
240
365
380
320
265
500
475
400
330
625
240
200
100
275
175
350
340
360
—
—
600
700
135
150
285
240
200
375
160
230
150
150
80
220
140
300
280
280
—
—
500
550
100
120
105
160
90
100
60
165
110
220
200
190
—
—
380
400
80
100
Refrigeración
pie2/ton†
Pro
Al
400
350
250
90
185
150
Ba
450
400
240
9.0†
2.0
5.5†
11†
30†
1.0
1.0
1.0
1.0
4†
1.0
1.5
1.5
1.5
1.5
4.0†
9†
25†
0.75
0.75
0.75
0.75
2.5†
0.75
1.25
1.0
1.0
1.0
2.5†
7.5†
12†
0.5
0.5
0.5
0.5
2†
0.5
1.0
0.5
0.5
0.5
35
150
250
50
80
150
60
110
125
85
400
360
15
50
200
200
70
100
200
80
130
150
100
600
600
17
23
100
300
25
50
100
40
80
100
70
200
200
13
Luces y Otro
Eléctrico W/pie2
Ba
Pro
Al
0.7
0.9
1.1
0.5
0.7
0.9
0.75
1.0
1.1
1.5
—
—
—
—
1.0
1.0
1.0
1.0
1.0
1.2
—
0.8
0.7
1.8
1.5
2.6
—
—
—
—
1.5
1.25
1.40
1.6
1.6
1.8
—
1.2
1.1
2.4
2.0
4.2
—
—
—
—
2.0
1.45
1.5
2.1
2.2
2.4
—
1.6
1.4
3.7
3.0
1.1
—
—
—
—
0.8
1.0
0.9
0.9
0.9
1.1
—
0.5
0.5
1.2
1.1
1.7
—
—
—
—
1.2
1.1
1.2
1.1
1.3
1.5
—
0.8
0.7
1.6
1.4
Tasa de Suministro de Aire
Este-Sur-Oeste
Norte
Ba
Pro
Al
Ba
Pro
0.8
1.2
1.7
0.5
0.8
—
—
—
—
—
1.0
1.6
2.2
0.9
1.3
2.6
—
—
—
—
1.4
1.2
1.4
1.3
2.0
1.8
—
1.3
1.2
2.1
1.8
Al
1.3
—
2.0
0.9
1.1
2.0
1.6
2.5
0.7
0.95
—
0.9
0.8
0.8
0.9
—
—
0.9
0.9
1.3
1.8
3.6
2.5
4.0
1.0
1.0
—
1.0
1.0
1.2
1.3
—
—
1.1
1.0
cfm/pie2
Interna
Pro
—
2.0
1.2
Ba
—
1.0
0.8
2.0
2.5
5.5
3.8
6.5
1.3
1.1
—
1.1
1.2
1.4
2.0
—
—
1.4
1.3
Al
—
3.0
1.9
Refrigeración y cantidades de aire para las aplicaciones enumeradas en esta tabla de cifras de verificación de carga de refrigeración están basadas en todo el sistema de aire y cantidades de aire exterior normales para ventilación excepto como se indica.
†Las cargas de refrigeración son para toda la aplicación
*Cantidades de aire para áreas de fabricación pesada están basadas en medios suplementarios para remover el calor excesivo.
Clasificaciones
Apartamento, Gran Altura
Auditorios, Iglesias,Teatros
Instalaciones Educativas
Escuelas, Colegios, Univers.
Fábricas,
Áreas de Ensamb.
Industria Ligera
Industria Pesada*
Hospitales
Cuartos de Pacientes
Áreas Públicas
Hoteles, Moteles, Dormitorio
Bibliotecas y Museos
Edificios de Oficina (general)
Oficinas Privadas
Departamento Estenográfico
Residencial
Grande
Medio
Restaurantes Grandes
Medio
Centros Comerciales, Tiendas de Departamentos
y Tiendas Especializadas
Salones de Belleza y Peluquería.
Centros Comerciales
Refrigeración para calefacción central y planta de
refrigeración
Distritos Urbanos
Campos Universitarios
Centros Comerciales
Centros Residenciales
Datos de Carga de Aire
Cifras de Verificación de Carga de Refrigeración
Ocupación pie2/
Persona
Ba
Pro
Al
325
175
100
15
11
6
30
25
20
Tabla 12.1 (I-P)
12.fm Page 252 Thursday, March 3, 2016 2:00 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
252
3.7
7.0
9.3
4.6
2.3
10.8
16.1
21.5
32.3† 53.8† 96.9†
59†
118†
323†
10.8
10.8
10.8
10.8
43†
10.8
16.1
16.1
16.1
16.1
4.2
43†
97†
269†
8.1I
8.1
8.1
8.1
27†
8.1
13.5
10.8
10.8
10.8
27†
81†
129†
5.4
5.4
5.4
5.4
22†
5.4
10.8
5.4
5.4
5.4
3.3
13.9
23.2
4.6
7.4
13.9
5.6
10.2
11.6
7.9
37.2
33.4
1.4
4.6
18.6
27.9
7.0
9.3
18.6
7.4
12.1
13.9
9.3
55.7
55.7
1.6
2.3
9.3
18.6
2.3
4.6
9.3
3.7
7.4
9.3
6.5
18.6
18.6
1.2
Luces y Otro
Eléctrico W/m2
Ba
Pro
Al
7.5
9.7
11.8
5.4
7.5
9.7
8.1
10.8 11.8
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
6.1
10.0
8.5
7.0
13.2
12.5
10.6
8.7
16.5
4.2
4.0
4.0
2.1
5.8
3.7
7.9
7.4
7.4
13.2
14.5
2.6
3.2
9.6
6.3
6.3
5.3
2.6
7.3
4.6
9.2
9.0
9.5
15.8
18.5
3.6
4.0
7.5
6.3
5.3
9.9
4.2
2.8
2.4
2.6
1.6
4.4
2.9
5.8
5.3
5.0
10.0
10.6
2.1
2.6
Refrigeración m2/
kW†
Ba
Pro
Al
11.9 10.6
9.2
10.6
6.6
2.4
6.3
4.9
4.0
-
7.6
5.1
5.1
5.1
5.1
5.1
6.1
4.1
3.6
9.1
7.6
-
13.2
7.6
6.4
7.1
8.1
8.1
9.1
6.1
5.6
12.2
10.2
-
21.3
10.2
7.4
7.6
10.7
11.2
12.2
8.1
7.1
18.8
15.2
-
5.6
4.1
5.1
4.6
4.6
4.6
5.6
2.5
2.5
6.1
5.6
-
8.6
6.1
5.6
6.1
5.6
6.6
7.6
4.1
3.6
8.1
7.1
-
13.2
7.1
6.1
7.1
6.6
10.2
9.1
6.6
6.1
10.7
9.1
Tasa de Suministro de Aire
Este-Sur-Oeste
Norte
Ba
Pro
Al
Ba
Pro
Al
4.1
6.1
8.6
2.5
4.1
8.6
10.2
8.1
11.2
4.6
6.6
10.2
5.6
4.6
10.2
8.1
12.7
3.6
4.8
4.6
4.1
4.1
4.6
4.6
4.6
9.1
6.6
18.3
12.7
20.3
5.1
5.1
5.1
5.1
6.1
6.6
5.6
5.1
L/sm2
Interna
Ba
Pro
0.0
0.0
5.1
10.2
4.1
6.1
12.7
10.2
27.9
19.3
33.0
5.6
5.6
5.6
6.1
7.1
10.2
7.1
6.6
Al
0.0
15.2
9.7
Refrigeración y cantidades de aire para las aplicaciones enumeradas en esta tabla de cifras de verificación de carga de refrigeración están basadas en todo el sistema de aire y cantidades de aire exterior normales para ventilación excepto como se indica.
†Las cargas de refrigeración son para toda la aplicación
*Cantidades de aire para áreas de fabricación pesada están basadas en medios suplementarios para remover el calor excesivo.
Apartamento, Gran Altura
Auditorios, Iglesias, Teatros
Instalaciones Educativas
Escuelas, Colegios, Universidades
Fábricas,
Áreas de Ensamblaje
Industria Ligera
Industria Pesada*
Hospitales
Cuartos de Pacientes
Áreas Públicas
Hoteles, Moteles, Dormitorios
Bibliotecas y Museos
Edificios de Oficinas (General)
Oficinas Privadas
Departamento Estenográfico
Residencial
Grande
Medio
Restaurantes
Grande
Medio
Centros Comerciales, Tiendas de Departamentos
y Tiendas de Especialidades
Salones de Belleza y Peluquerías
Centros Comerciales
Refrigeración para Central de Calefacción y
Planta de Refrigeración
Distritos Urbanos
Campos Universitarios
Centros Comerciales
Centros Residenciales
Clasificaciones
Cifras de Verificación de Carga de Refrigeración
Ocupación m2/
Persona
Ba
Pro
Al
30.2 16.3
9.3
1.4
1.0
0.6
2.8
2.3
1.9
Tabla 12.1 (SI)
12.fm Page 253 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
253
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
12.fm Page 254 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
q = UA(CLTD)
Paredes
q = UA(CLTD)
Conducción
de Vidrio
q = UA(CLTD)
Vidrio Solar
q = A(SC)SCL
Particiones,
Cielo raso,
Pisos
q = UA(TD)
Diseño de coeficientes de transmisión de
calor, pp. 179–84
Área calculada de los planos
q = ENTRADA
Evaluación de entrada de planos
eléctricos o datos de artefactos de
alumbrado, pp. 194–96 (191–94)
Interno
Luces
Ecuación
Referencia, Tabla, Descripción
Diseño de coeficientes de transmisión de
calor, pp. 179–84
Areas calculadas de los planos CLTD, pp.
185–86
Diseño de coeficientes de transmisión de
calor, pp. 179–84
Áreas calculadas de los planos CLTD, pp.
187–89
Área de Cristal calculada de los planos
Factores-U p. 174
CLTD para conducción de la carga a
través del cristal, p. 174
Factores de carga de refrigeración solar,
pp. 190–91 (188)
Área de cristal neta de los planos
Coeficientes de sombreado para
combinación de cristal y sombreado
interno , p. 192 (189)
Calcular el área de sombreado de las
proyecciones de construcción
Cristal sombreado externamente: utilizar
datos de orientación norte
Gente
Sensible
Latente
Equipo y Artefactos
Energía
Aire de Infiltración
Sensible
Latente
Total
qs = No. (Sens. H.G.)
Número de gente en el espacio
Ganancia del calor sensible de ocupantes,
p. 193 (190)
Ganancia de calor latente de ocupantes
ql = No. (Lat. H.G.)
qs = GANANCIA DE CALOR Tasa recomendada de ganancia de calor,
pp. 197–210 (206)
q = GANANCIA DE CALOR pp. 198–99 (195–96)
Q = L/s (SI)
Diferencia de temperatura de aire
qs = 1.10 (CFM) t (I-P)
interior-exterior, °F (°C)
qs = 120Q t (SI)
Diferencia de relación de humedad de
ql = 4840 (CFM) W (I-P)
aire interior-exterior, grano/lbda (g/kW)
ql = 3.0Q W (SI)
q = 4.5 (CFM) h (I-P)
Diferencia de entalpia de aire interiorq = 1.20Q h (SI)
exterior, Btu/lbda (kJ/kg)
ADVERTENCIA: datos aproximados – Utilizado para cálculos preliminares solamente. Ver Manual de Aplicación
para Cálculo de Carga de Calor y Refrigeración de ASHRAE (Spitler 2008) y Juego de Herramientas para Cálculo
de Carga de ASHRAE.
254
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Fuente de Carga
Externo
Techo
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.2 Resumen de las Fuentes de Carga y Ecuaciones para
Diseño de Espacios Estimados para Cargas de Refrigeración
12.fm Page 255 Thursday, March 3, 2016 2:00 PM
(Además del flujo de calor a través de los materiales de construcción la resistencia de las
superficies y espacios de aire deben ser incluidas en el cálculo de los factores-U.)
Q (Btu/h) = U  Area (ft2)  diferencia de temperatura (°F)
(I-P)
Q (W) = U  Area (m2)  diferencia de temperatura (K)
(SI)
donde U = coeficiente global de transmisión de calor, Btu/h·ft2·°F (W/[m2·K]), de materiales +
resistencias interior y exterior:
1/U = R (resistencia de componentes)
Para capas múltiples de materiales homogéneos, los valores R son agregados en series :
+ 0.25 R perno


-  + R superficie caliente
1\U = R superficie fria +  --------------------------------------------------------------- + 0.75 R espacio de perno 
(Además, en serie, Raislamiento, Rentablado, R cartón de yeso, etc.)
Flujo de Calor por Conducción a Través del Acristalamiento
La ganancia de radiación solar a través del acristalamiento es usualmente más significativa en
cálculos de carga de refrigeración que la ganancia de calor por conducción. La ganancia de calor
solar es descuidada en los cálculos de carga de calefacción.
Flujo de calor por conducción a través del acristalamiento incluye resistencia de la superficie
(datos aproximados)
Acristalamiento simple
U = 1.1 (6.2)
Acristalamiento doble
U = 0.55 (3.1)
Acristalamiento triple
U = 0.33 (1.9)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
255
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos de Carga de Aire
1/U = Rsuperficie fria + R1 + R2 + Rn... + Rsuperficie caliente
Para paredes de entramado de madera, entramado 16 in. (400 mm) en el centro (series y paralelo):
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Flujo de Calor Q a través de los Materiales de Construcción
12.fm Page 256 Thursday, March 3, 2016 2:00 PM
Resistencia Térmica Efectiva de Espacios de Aire Plano,a, b, c
h·pie2·F/Btu [2013F, Ch 26, Tbl3]
Espacio de Aire
Emitancia Efectiva effd,e
Posición
Dirección
de
0.75 in. Espacio de Airec
0.5 in. Espacio de Airec
de Flujo Temp.d Temp.
d
Espacio
Térmico Media., Dif.,
de Aire
0.03 0.05 0.2 0.5 0.82 0.03 0.05 0.2 0.5 0.82
°F
°F
Subida
Datos de Carga de Aire
Horiz.
10
2.13 2.03 1.51 0.99 0.73 2.34 2.22 1.61 1.04 0.75
50
30
1.62 1.57 1.29 0.96 0.75 1.71 1.66 1.35 0.99 0.77
50
10
2.13 2.05 1.60 1.11 0.84 2.30 2.21 1.70 1.16 0.87
0
20
1.73 1.70 1.45 1.12 0.91 1.83 1.79 1.52 1.16 0.93
0
10
2.10 2.04 1.70 1.27 1.00 2.23 2.16 1.78 1.31 1.02
20
1.69 1.66 1.49 1.23 1.04 1.77 1.74 1.55 1.27 1.07
10
2.04 2.00 1.75 1.40 1.16 2.16 2.11 1.84 1.46 1.20
90
10
2.47 2.34 1.67 1.06 0.77 3.50 3.24 2.08 1.22 0.84
50
30
2.57 2.46 1.84 1.23 0.90 2.91 2.77 2.01 1.30 0.94
50
10
2.66 2.54 1.88 1.24 0.91 3.70 3.46 2.35 1.43 1.01
0
20
2.82 2.72 2.14 1.50 1.13 3.14 3.02 2.32 1.58 1.18
0
10
2.93 2.82 2.20 1.53 1.15 3.77 3.59 2.64 1.73 1.26
20
2.90 2.82 2.35 1.76 1.39 2.90 2.83 2.36 1.77 1.39
10
3.20 3.10 2.54 1.87 1.46 3.72 3.60 2.87 2.04 1.56
90
10
2.48 2.34 1.67 1.06 0.77 3.55 3.29 2.10 1.22 0.85
50
30
2.66 2.54 1.88 1.24 0.91 3.77 3.52 2.38 1.44 1.02
50
10
2.67 2.55 1.89 1.25 0.92 3.84 3.59 2.41 1.45 1.02
0
20
2.94 2.83 2.20 1.53 1.15 4.18 3.96 2.83 1.81 1.30
0
10
2.96 2.85 2.22 1.53 1.16 4.25 4.02 2.87 1.82 1.31
20
3.25 3.15 2.58 1.89 1.47 4.60 4.41 3.36 2.28 1.69
10
3.28 3.18 2.60 1.90 1.47 4.71 4.51 3.42 2.30 1.71
50
50
Horiz.
Vertical
50
50
Bajada
Horiz.
50
50
a Ver Capítulo 25 del Manual –Fundamentales de ASHRAE (2013). Valores de resistencia térmica de R = 1/C, donde
C = hc +  eff hr, hc es ,  eff hr es coeficiente de radiación  0.0068 eff [(tm + 460)/100]3, y tm es temperatura media
del espacio de aire.
b Valores aplican por condiciones ideales (ej. espacios de aire de espesor uniforme delimitados por superficies para-
lelas, lisas, planas sin fuga hacia o desde el espacio). Esta tabla no debe utilizarse para revestimiento hueco o
revestimiento perfilado.
valor de resistencia individual no puede dar cuenta de múltiples espacios de aire; cada espacio de aire requiere
un cálculo de resistencia separada que aplique sólo para condiciones delimitadas establecidas. Resistencias de espacios horizontales con flujo de calor descendentes son independientes substancialmente de la diferencia de temperatura.
d La interpolación es permitida para otros valores de temperatura media, diferencia de temperatura, y emitancia efectiva  eff. La interpolación y extrapolación moderada para espacios de aire mayores de 3.5 pulg. también es permitido.
e La emitancia efectiva  del espacio de aire está dada por 1/ = 1/ + 1/  1, donde  y  son emitancias de
eff
eff
1
2
1
2
espacio de aire (ver Tabla 12.2). También, la oxidación, corrosión y acumulación de polvo y suciedad puede
dramáticamente incrementar la emitancia de la superficie. Los valores de emitancia de 0.05 solamente
deberían ser utilizados donde la superficie altamente reflectante puede ser mantenida sobre la vida útil del
montaje.
c Un
256
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
90
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.3 (I-P)
12.fm Page 257 Thursday, March 3, 2016 2:00 PM
Resistencia Térmica de Espacios de Aire Planos,a,b,c
(m2·K)/W [2013F, Ch 26, Tbl 3]
Espacio de Air
Emitancia Efectiva eff d,e
Posición
Dirección
del
20 mm Espacio de Airec
13 mm Espacio de Airec
de Flujo Temp.d Temp.
d
Espacio
Térmico Media., Dif., 0.03 0.05 0.2 0.5 0.82 0.03 0.05 0.2 0.5 0.82
de Aire
°C
K
Subida




Horiz.
Horiz.




Vertical
Bajada
Horiz.




5.6
16.7
5.6
11.1
5.6
11.1
5.6
5.6
16.7
5.6
11.1
5.6
11.1
5.6
5.6
16.7
5.6
11.1
5.6
11.1
5.6
0.37
0.29
0.37
0.30
0.37
0.30
0.36
0.43
0.45
0.47
0.50
0.52
0.51
0.56
0.44
0.47
0.47
0.52
0.52
0.57
0.58
0.36
0.28
0.36
0.30
0.36
0.29
0.35
0.41
0.43
0.45
0.48
0.50
0.50
0.55
0.41
0.45
0.45
0.50
0.50
0.55
0.56
0.27
0.23
0.28
0.26
0.30
0.26
0.31
0.29
0.32
0.33
0.38
0.39
0.41
0.45
0.29
0.33
0.33
0.39
0.39
0.45
0.46
0.17
0.17
0.20
0.20
0.22
0.22
0.25
0.19
0.22
0.22
0.26
0.27
0.31
0.33
0.19
0.22
0.22
0.27
0.27
0.33
0.33
0.13
0.13
0.15
0.16
0.18
0.18
0.20
0.14
0.16
0.16
0.20
0.20
0.24
0.26
0.14
0.16
0.16
0.20
0.20
0.26
0.26
0.41
0.30
0.40
0.32
0.39
0.31
0.38
0.62
0.51
0.65
0.55
0.66
0.51
0.65
0.62
0.66
0.68
0.74
0.75
0.81
0.83
0.39
0.29
0.39
0.32
0.38
0.31
0.37
0.57
0.49
0.61
0.53
0.63
0.50
0.63
0.58
0.62
0.63
0.70
0.71
0.78
0.79
0.28
0.24
0.30
0.27
0.31
0.27
0.32
0.37
0.35
0.41
0.41
0.46
0.42
0.51
0.37
0.42
0.42
0.50
0.51
0.59
0.60
0.18
0.17
0.20
0.20
0.23
0.22
0.26
0.21
0.23
0.25
0.28
0.30
0.31
0.36
0.21
0.25
0.26
0.32
0.32
0.40
0.40
0.13
0.14
0.15
0.16
0.18
0.19
0.21
0.15
0.17
0.18
0.21
0.22
0.24
0.27
0.15
0.18
0.18
0.23
0.23
0.30
0.30
media del espacio de aire.
condiciones ideales (ej. espacios de aire de espesor uniforme delimitados por superficies paralelas, lisas, planas sin fuga hacia o desde el espacio). Esta tabla no debe utilizarse para revestimiento hueco o
revestimiento perfilado.
c Un valor de resistencia individual no puede dar cuenta de múltiples espacios de aire; cada espacio de aire requiere un
cálculo de resistencia separada que aplique sólo para condiciones delimitadas establecidas. Resistencias de espacios
horizontales con flujo de calor descendentes son independientes substancialmente de la diferencia de temperatura.
d La interpolación es permitida para otros valores de temperatura media, diferencia de temperatura, y emitancia efectiva  eff. La interpolación y extrapolación moderada para espacios de aire mayores de 90 mm. también es permitido.
e La emitancia efectiva  del espacio de aire está dada por 1/ = 1/ + 1/  1, donde  y  son emitancias de
eff
eff
1
2
1
2
espacio de aire (ver Tabla 12.2). También, la oxidación, corrosión y acumulación de polvo y suciedad puede
dramáticamente incrementar la emitancia de la superficie. Los valores de emitancia de 0.05 solamente
deberían ser utilizados donde la superficie altamente reflectante puede ser mantenida sobre la vida útil del
montaje.
b Valores aplican por
257
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
a Ver Capítulo 25. Valores de resistencia térmica fueron determinados de R = 1/C, donde C = h +  h , h es coeficic
eff r c
ente de conducción/convección,  eff hr es coeficiente de radiación  0.227 eff [(tm + 273)/100]3, y tm es temperatura
Datos de Carga de Aire
32.2
10.0
10.0
17.8
17.8
45.6
45.6
32.2
10.0
10.0
17.8
17.8
45.6
45.6
32.2
10.0
10.0
17.8
17.8
45.6
45.6
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.3 (SI)
12.fm Page 258 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
Posición de
Superficie
Película Superficial Coeficientes/Resistencias [2013, Ch 26, Tbl 10]
Dirección de
Flujo Térmico
Interior
Horizontal
Ascendente
Inclinación a 45°
Ascendente
Vertical
Horizontal
Inclinación a 45°
Descendente
Horizontal
Descendente
Exterior (cualquier posición)
Viento 15 mph
Cualquiera
(para invierno)
Viento7.5 mph
Cualquiera
(para verano)
hi
1.63
1.60
1.46
1.32
1.08
ho
Emitancia de Superficie, 
Reflectante
 = 0.20
 = 0.05
Ri
hi
Ri
hi
Ri
0.61
0.91
1.10
0.76
1.32
0.62
0.88
1.14
0.73
1.37
0.68
0.74
1.35
0.59
1.70
0.76
0.60
1.67
0.45
2.22
0.92
0.37
2.70
0.22
4.55
Ro
6.00
0.17
—
—
—
—
4.00
0.25
—
—
—
—
No Reflectante
 = 0.90
Notas:
1. Conductancia de superficie hi y ho medido en Btu/h·ft2·°F; resistencia Ri y Ro en h·pie2·°F/Btu.
2. Ninguna superficie tiene ambos un valor de resistencia del espacio de aire y un valor de resistencia superficial.
3. Las conductancias son para las superficies de la emitancia declarada frente a los alrededores virtuales del cuerpo
negro a la misma temperatura como el aire ambiente. Valores basados en temperatura de superficie/aire diferencia
de 10°F y temperaturas de superficie de 70°F.
4. Ver Capítulo 4 para información más detallada.
5. El condensado puede tener efecto significativo en la emitancia de superficie (ver Tabla 12.2). También, la oxidación, corrosión y acumulación de polvo y suciedad puede dramáticamente incrementar la emitancia de la superficie. Los valores de emitancia de 0.05 solamente deberían ser utilizados donde la superficie altamente reflectante
puede ser mantenida sobre la vida útil del montaje.
Tabla 12.4 (SI) Película Superficial Coeficientes/Resistencias [2013F, Ch 26, Tbl 10]
Posición de
Superficie
Dirección de
Flujo Térmico
Viento (para
verano) a 3.4 m/s
Cualquiera
hi
9.26
9.09
8.29
7.50
6.13
ho
34.0
0.030
—
—
—
—
22.7
0.044
—
—
—
—
Notas:
1. Conductancia de superficie hi y ho medido en W/(m2 K); resistencia Ri y Ro en (m2·K)/W.
2. Ninguna superficie tiene ambos un valor de resistencia del espacio de aire y un valor de resistencia superficial.
3. Las conductancias son para las superficies de la emitancia declarada frente a los alrededores virtuales del cuerpo
negro a la misma temperatura como el aire ambiente. Valores basados en temperatura de superficie/aire diferencia
de 5.6 K y temperaturas de superficie de 21°C.
4. Ver Capítulo 4 para información más detallada.
5. El condensado puede tener efecto significativo en la emitancia de superficie (ver Tabla 12.2). También, la oxidación, corrosión y acumulación de polvo y suciedad puede dramáticamente incrementar la emitancia de la superficie. Los valores de emitancia de 0.05 solamente deberían ser utilizados donde la superficie altamente reflectante
puede ser mantenida sobre la vida útil del montaje.
258
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Interior
Horizontal
Ascendente
Inclinación a 45° Ascendente
Vertical
Horizontal
Inclinación a 45° Descendente
Horizontal
Descendente
Exterior (cualquier posición)
Viento (para
Cualquiera
invierno) a 6.7 m/s
Emitancia de Superficie, 
Reflectante
 = 0.20
 = 0.05
Ri
hi
Ri
hi
Ri
0.11
5.17
0.19
4.32
0.23
0.11
5.00
0.20
4.15
0.24
0.12
4.20
0.24
3.35
0.30
0.13
3.41
0.29
2.56
0.39
0.16
2.10
0.48
1.25
0.80
Ro
No reflectante
 = 0.90
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.4 (I-P)
12.fm Page 259 Thursday, March 3, 2016 2:00 PM
Película Superficial Europea Coeficientes/Resistencias
[2013, Ch 26, Tbl 11]
Posición de Superficie
Interiores
Horizontal, inclinación a 45°
Dirección de Flujo
Térmico
Ascendente
Descendente
Vertical, inclinación más allá de 45°
Exteriores
Tabla 12.5 (SI)
Cualquier dirección
h,
Btu/h·pie2·°F
R,
h·pie2·°F/Btu
1.76
1.06
1.36
4.4
0.57
0.97
0.74
0.23
Película Superficial Europea [2013F, Ch 26, Tbl 11]
Interiores
Horizontal, inclinación a 45°
Dirección de Flujo
Térmico
h,
W/(m2·K)
R,
(m2·K)/W
10
6
7.7
25
0.1
0.17
0.13
0.04
Ascendente
Descendente
Vertical, inclinación más allá de 45°
Exteriores
Tabla 12.6
Cualquier dirección
Emisividad de Varias Superficies y Emitancias Efectivas de
Cara a los Espacios de Airea [2013F, Ch 26, Tbl 2]
Superficie
a
b
0.30b
b
0.29
—
0.65
—
0.12
0.20
0.04
0.74
0.04
0.2
0.58
0.27
0.06
0.03
0.25
0.05
0.50
0.12
0.20
0.038
0.41
0.038
0.16
0.35
0.21
0.056
0.029
0.24
0.047
0.47
0.06
0.11
0.02
0.59
0.02
0.11
0.41
0.16
0.03
0.015
0.15
0.026
0.35
0.90
0.82
0.82
0.84
0.77
0.72
0.70
Valores aplican en un margen de 4 to 40 m de espectro electromagnético. También, oxidación, corrosión y acumulación de polvo y suciedad, puede incrementar dramáticamente la emitancia de la superficie. . Los valores de emitancia de 0.05 deben ser solamente utilizados donde la superficie altamente reflectiva puede ser mantenida sobre la
vida útil del ensamblaje. Excepto como se indica, datos de. VDI (1999).
Valores basados en datos en Bassett y Trethowen (1984).
259
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Papel aluminio, brillante
Papel aluminio, con condensado apenas
visible >0.7 g/pie2 (>0.5 g/m2)
Papel de aluminio con condensado
claramente visible >2.9 g/pie2 (>2.0 g/m2)
Hoja de aluminio
Aluminio-papel recubierto, pulido
Latón, no oxidado
Cobre, negro oxidado
Cobre, pulido
Hierro y acero, pulido
Hierro y acero, oxidado
Plomo, oxidado
Níquel, no oxidado
Plata, pulida
Acero, galvanizado, brillante
Estaño, no oxidado
Pintura de aluminio
Materiales de construcción: madera, papel,
mampostería, pinturas no metálicas
Vidrio ordinario
Emitancia Efectiva eff
de Espacio de Aire
Emisividad
Emitancia de
Promedio  Emitancia de una
Superficie ;
Ambas
Otro, 0.9
Superficies 
0.05
0.05
0.03
Datos de Carga de Aire
Posición de Superficie
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.5 (I-P)
12.fm Page 260 Thursday, March 3, 2016 2:00 PM
Temp. de Temp.
Aire de
AireVentilación, Sole,
°F
°F
Datos de Carga de Aire
c
d
e
f
80
120
140
160
1.9
1.9
1.9
100
120
140
160
1.9
1.9
1.9
80
120
140
160
100
120
140
160
4.4
6.1
7.6
4.0
5.8
7.2
6.0
8.7
11
4.1
6.5
8.3
6.9
10
13
6.5
6.5
6.5
1.9
2.2
2.3
3.3
1.9
2.4
2.7
4.2
1.9
2.6
3.2
5.0
Parte B. Superficie Reflectivaf
6.5
8.1
8.8
13
6.5
8.2
9.0
14
6.5
8.3
9.2
15
17
18
18
17
18
19
25
26
27
19
20
21
30
31
32
6.5
6.5
6.5
6.5
6.5
6.5
10
12
14
8.5
11
13
12
15
18
8.8
12
15
12
16
20
7.0
7.3
7.6
7.4
7.8
8.2
8.0
10
11
Aunque el término resistencia efectiva es comúnmente utilizado cuando hay ventilación en el ático, esta tabla
incluye valores para situaciones sin ventilación. La resistencia efectiva del ático agregada a la resistencia (1/U) del
techo rinde la resistencia efectiva de esta combinación basado en temperaturas de habitación y aire-sol. Estos
valores aplicados a una estructura de madera con una cubierta de la azotea y techado que tiene una conductancia de
1.0 Btu/h.pie2·°F.
Esta condición no puede ser lograda en el campo a no ser que se tomen medidas extremas para sellar herméticamente el ático.
Basado en la descarga de aire hacia afuera del ático.
Cuando se determine la resistencia del techo, no agregue el efecto de una superficie reflectante hacia el ático,
como se da razón en la parte B de esta tabla.
Temperatura de la superficie del techo en vez de temperatura aire-sol puede ser utilizada si 0.25 es restada de la
resistencia del ático mostrada.
Las superficies con emitancia efectiva  eff = 0.05 entre las vigas techo hacia el espacio del ático.
260
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
b
Ventilacion
Ventilacion Mecánicac
Natural
Tasa de Ventilacion, cfm/p2
0
0.1
0.5
1.0
1.5
Resistencia de Techo Rd, °F·p2·h/Btu
20
10
20
10
20
10
20
10
20
Parte A. Superficies No reflectivas
1.9
2.8
3.4
6.3 9.3 9.6
16
11
20
1.9
2.8
3.5
6.5
10
9.8
17
12
21
1.9
2.8
3.6
6.7
11
10
18
13
22
Sin
Ventilacionb
10
a
Resistencia Térmica Efectiva de Áticos Ventiladosa
(Condición de Verano)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.7 (I-P)
12.fm Page 261 Thursday, March 3, 2016 2:00 PM
49
60
71
32
49
60
71
0.33
0.33
0.33
38
49
60
71
0.33
0.33
0.33
27
49
60
71
0.33
0.39
0.40 0.58 0.77
0.33
0.42
0.48 0.74 1.07
0.33
0.46
0.56 0.88 1.34
Parte B. Superficies reflectantesf
1.14
1.14
1.43
1.55 2.29 2.99
1.14
1.14
1.44
1.58 2.46 3.17
1.14
1.14
1.46
1.62 2.64 3.17
32
49
60
71
1.14
1.14
1.14
1.14
1.14
1.14
1.32
1.36
1.39
1.41
1.46
1.51
1.76 2.29 2.11 2.99 2.29 3.34
2.11 2.64 2.46 3.52 2.82 3.87
2.29 2.82 2.82 3.87 3.17 4.40
38
49
60
71
1.14
1.14
1.14
1.14
1.14
1.14
1.23
1.28
1.34
1.30
1.37
1.44
1.41 1.76 1.50 2.11 1.55 2.11
1.76 2.11 1.94 2.64 2.11 2.82
1.94 2.46 2.29 3.17 2.64 3.52
c
d
e
f
0.33
0.33
0.33
0.44
0.46
0.48
0.49
0.55
0.60
0.81 1.18 1.07 1.76 1.21 2.29
0.92 1.39 1.34 2.11 1.51 2.64
1.02 1.58 1.50 2.46 1.76 2.99
0.70 1.06 0.72 1.21
1.02 1.53 1.14 1.76
1.27 1.94 1.46 2.29
2.99 4.40 3.34 5.28
3.17 4.58 3.52 5.46
3.34 4.75 3.70 5.63
Aunque el término resistencia efectiva es comúnmente utilizado cuando hay ventilación en el ático, esta tabla
incluye valores para situaciones sin ventilación. La resistencia efectiva del ático agregada a la resistencia (1/U) del
techo rinde la resistencia efectiva de esta combinación basado en temperaturas de habitación y aire-sol. Estos
valores aplicados a una estructura de madera con una cubierta de la azotea y techado que tiene una conductancia de
5.7 W/(m2·K)
Esta condición no puede ser lograda en el campo a no ser que se tomen medidas extremas para sellar herméticamente el ático.
Basado en la descarga de aire hacia afuera del ático.
Cuando se determine la resistencia del techo, no agregue el efecto de una superficie reflectante hacia el ático, como
se da razón en la parte B de esta tabla.
Temperatura de la superficie del techo en vez de temperatura aire-sol puede ser utilizada si 0.04 es restada de la
resistencia del ático mostrada.
Las superficies con emitancia efectiva  eff = 0.05 entre las vigas techo hacia el espacio del ático.
261
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos de Carga de Aire
b
Sin
Ventilacionb
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
27
Ventilacion
Ventilacion Mecánicac
Natural
Tasa de Ventilación, L/s por m2
0
0.1
0.5
1.0
1.5
Resistencia de Techo Rd, K·m2·/W
10
20
10
20
10
20
10
20
10
20
Parte A. Superficies no reflectantes
0.33
0.33
0.49
0.60 1.11 1.64 1.69 2.82 1.94 3.52
0.33
0.33
0.49
0.62 1.14 1.76 1.72 2.99 2.11 3.70
0.33
0.33
0.49
0.63 1.18 1.94 1.76 3.17 2.29 3.87
Temp. de Temp.
Aire de
AireVentilación, Sole,
°C
°C
a
Resistencia Térmica Efectiva de Áticos Ventiladosa
(Condición de Verano)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.7 (SI)
12.fm Page 262 Thursday, March 3, 2016 2:00 PM
Construcción y Materiales Aislantes: Valores de Diseñoa
[2013F, Ch 26, Tbl 1]
Descripción
Densidad,
lb/pie3
Resistencia
Calor
Conductividadb
R,
Específico
k,
2
cp,
2·°F h·pie ·°F/
Btu·in/h·pie
Btu
Btu/lb·°F
Materiales Aislantes
Mantas y bloquesc,d
Bloques de fibra de vidrio
Datos de Carga de Aire
Roca y bloquees de lana de escoria
Lana mineral, filtro
Tablero y losas
Vidrio celular
Losas de fibra de cemento, madera triturada con cemento
Portland aglomerado con oxysulfido de magnesia
Tablero de fibra de vidrio
Caucho expandido (rígido)
Poliestireno extruido, piel suave
Envejecido por Can/ULC/ Norma S770-2003
Envejecido 180 días
Producto europeo
Envejecido 5 años a 75°F
Soplado con potencial de calentamiento global (GWP) (<5)
agente de expansión
Poliestireno expandido, perlas moldeadas
Fibra de vidriod
Áticos, ~4 a 12 pulg.
Áticos, ~12 a 22 pulg.
Ático cerrado o cavidades de pared
Roca y bloques de lanad
Áticos, ~3.5 a 4.5 pulg.
Áticos, ~5 a 17 pug.
Ático cerrado o cavidades de pared
Vermiculita, dilatada
Rociador aplicado
Celulosa, rociada en las cavidades de pared abiertas
Fibra de vidrio, rociada en pared abierta o cavidades del
ático
Espuma de poliuretano
Densidad baja, célula abierta
Densidad media, célula cerrada, envejecido 180 días
0.32 a 0.33
0.28 a 0.30
0.26 a 0.27
0.23
—
0.25 a 0.26
0.23 a 0.24
0.28
0.24
—
—
—
—
—
—
—
—
—
0.2
—
—
—
—
0.2
—
—
—
—
7.5
25 a 27
22
—
1.5 a 6.0
4
—
1.4 a 3.6
1.4 a 3.6
1.9
2 a 2.2
0.29
0.50 a 0.53
0.57
—
0.23 a 0.24
0.2
—
0.18 a 0.20
0.20
0.21
0.21
—
—
—
—
—
—
—
—
0.20
—
0.31
0.2
—
0.4
0.35
—
—
—
0.24 a 0.25
—
—
—
1.0 a 1.5
1.8
10
—
4.0 a 8.0
10. a 11.
21 a 23
9
—
—
0.24 a 0.26
0.23
0.26
—
0.23 a 0.25
0.27 a 0.29
0.36 a 0.37
0.36
—
—
—
—
—
—
—
—
—
—
—
0.35
—
—
0.2
0.2
—
0.2
0.14 a 0.19
—
0.35
1.6 a 2.3
0.16 a 0.17
—
—
—
—
0.15 a 0.16
0.14 a 0.16
—
—
—
—
—
1.0 a 1.2
1.2 a 1.6
3.5
2a4
4 a 7.5
7.5 a 11
—
0.31 a 0.32
0.27 a 0.28
0.27 – 0.28
0.27 a 0.31
0.31 a 0.36
0.36 a 0.42
—
—
—
—
—
—
—
0.33
—
—
—
0.26
—
—
0.4 a 0.5
0.5 a 0.6
1.8 a 2.3
0.36 a 0.38
0.34 a 0.36
0.24 a 0.25
—
—
—
—
—
—
1.5 a 1.6
1.5 a 1.8
4.0
7.0 a 8.2
4.0 a 6.0
0.34
0.32 a 0.33
0.27 a 0.29
0.47
0.44
—
—
—
—
—
—
—
—
0.32
—
1.6 a 2.6
0.27 a 0.28
—
—
1.0
0.27 a 0.29
—
—
1.8 a 2.3
—
0.45 a 0.65
1.9 a 3.2
0.23 a 0.26
—
0.26 a 0.29
0.14 a 0.20
—
—
—
—
—
0.35
—
—
262
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tablero de fibras mineral, fieltro mojado
Tablero fibra de lana
Pisos y paredes
Techo
Loseta acústicae
Tablero de perlita
Poliisocianurato
Sin revestir, envejecido por
Can/ULC Norma S770-2003
Con recubrimiento de aluminio, envejecido 180 días
Tablero de espuma fenólica con facers, envejecida
Relleno Suelto
Fibra de celulosa, relleno suelto
Aplicación ático hasta 4 pulg.
Aplicación ático > 4 pulg.
Aplicación pared, densamente compactada
Perlita, expandida
0.47 a 0.51
0.61 a 0.75
0.79 a 0.85
1.4
—
2 a 2.3
2.8
1a3
1a8
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (I-P)
12.fm Page 263 Thursday, March 3, 2016 2:00 PM
Construcción y Materiales Aislantes: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Descripción
Panel de Construcción y Revestimiento
Panel
Panel de asbesto/cemento
Panel de cemento
Panel de fibra/cemento
Densidad,
lb/pie3
—
—
—
—
—
—
—
0.62
0.68
0.79
0.85
1.08
0.24
0.2
0.2
0.2
0.45
0.45
0.21
0.45
0.45
0.45
0.45
0.45
—
—
—
—
—
0.4
0.5
0.5
1.32
1.09
1.06
0.94
1.35
—
—
—
0.31
0.31
0.31
0.3
0.3
0.14
0.33
0.28
0.73
0.82
1.0
—
—
—
0.31
0.32
0.32
0.71
0.94
1.18
0.73
0.63
—
—
0.85
0.82
0.21
0.31
0.31
—
0.29
0.45
—
—
—
—
0.21
0.87
1.19
1.4
—
0.31
0.28
0.31
—
—
—
—
—
0.21
0.15
0.21
0.15
0.79
0.24
0.35
0.24
0.35
0.28
—
—
—
0.81
1.05
0.59
—
—
—
6.9
0.62
1.82
2.96
—
0.28
0.28
0.29
—
0.29i
0.32
—
0.21
—
—
—
0.06
0.12
Inapreciable
—
—
—
—
—
—
—
2.8
—
—
2.38
0.68
1.59
0.51
—
0.34
0.08
—
—
—
—
—
—
0.19
263
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Yeso o tablero de yeso. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tableros de fibra orientada (OSB) . . . . . . . . . . . . . . . . . 7/16 in.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 pulg.
Madera terciada (abeto Douglas). . . . . . . . . . . . . . . . . . . . 1/2 in.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/8 pulg.
Madera terciada/paneles de madera . . . . . . . . . . . . . . . . . . 3/4 in.
Tablero de fibra vegetal
Revestimiento, densidad regular. . . . . . . . . . . . . . . . 1/2 in.
18
Densidad intermedia . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 in.
22
Revestimiento basado en clavo. . . . . . . . . . . . . . . . . 1/2 in.
25
Respaldo de tejas . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8 in.
18
Tablero de insonorización. . . . . . . . . . . . . . . . . . . . . 1/2 in.
15
Paneles de azulejos, planos o acústicos . . . . . . . . . . . . . . .
18
Laminado de cartón . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
Tablero homogéneo de papel de pulpa . . . . . . . . . . . . . . . .
30
Madera Prensada
Densidad media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50
Alta densidad, grados de servicio y servicio templado. . . .
55
Alta densidad, grado templado estándar . . . . . . . . . . . . . . .
63
Aglomerado
Densidad baja . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
Densidad media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50
Densidad alta . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
62
Contrapiso. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/8 in.
44
Tablero de plaqueta . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
Tejas
Asbesto cemento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
120
Madera, 16 pulg., 7 1/2 pulg. exposición . . . . . . . . . . . . . .
—
Madera, doble, 16 pulg., 12 pulg. exposición. . . . . . . . . . .
—
Madera, más pulg. tablero de respaldo . . . . . . . . . . 5/16 in.
—
Revestimiento
Asbesto/cemento, recubierto. . . . . . . . . . . . . . . . . . . 1/4 in.
—
Recubrimiento rollo de asfalto . . . . . . . . . . . . . . . . . . . . . .
—
Recubrimiento aislante de asfalto (1/2 pulg. cama) . . . . . .
—
Recubrimiento de madera prenaada . . . . . . . . . . . . 7/16 in.
—
Madera, gota, 8 pulg. . . . . . . . . . . . . . . . . . . . . . . . . . 1 in.
—
Madera, bizel
Recubierto, 8 pulg.. . . . . . . . . . . . . . . . . . . . . . . 1/2 in.
—
Recubierto, 10 pulg.. . . . . . . . . . . . . . . . . . . . . . 3/4 in.
—
Madera, madera terciada, 3/8 pulg. recubierto . . . . . . . . . .
—
Aluminio, acero o vinilo,h, i sobre-revestimiento . . . . . . . .
Hueco respaldado. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Tablero aislado respaldado . . . . . . . . . . . . . . . . 3/8 in.
—
Refuerzo de aluminio. . . . . . . . . . . . . . . . . . . . . 3/8 in.
—
Vidrio arquitectónico (soda, flotador de cal) . . . . . . . . . . .
158
Membrana de Edificio
Fieltro permeable al vapor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Vapor: sello, 2 capas de 15 lb de fieltro fregado . . . . . . . . . . . . . .
—
Vapor: sello, película plástica . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Materiales de Acabado de Piso
Alfombra, y almohadilla de uretano rebotado . . . . . . . . . . . 3/4 in.
7
Alfombra y almohadilla de caucho (una pieza). . . . . . . . . . 3/8 in.
20
Alfombra de pelo con almohadilla de caucho . . . . . 3/8 a 1/2 pulg
18
Linóleo/baldosas de corcho . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 in.
29
Recubrimiento de piso de caucho/PVC . . . . . . . . . . . . . . . . . . . . .
—
Baldosas de caucho. . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 in.
119
Terrazo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 in.
—
Metales (Ver Capítulo 33, Tabla 3 en el Manual – Fundamentales 2013 de ASHRAE)
4
1.7
1.7
1.3
0.5
0.4
1.1
—
—
—
—
—
Datos de Carga de Aire
120
71
88
61
26
20
40
41
41
29
34
28
Resistencia
Calor
Conductividadb
R,
Específico
k,
2
cp,
2·°F h·pie ·°F/
Btu·in/h·pie
Btu
Btu/lb·°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (I-P)
12.fm Page 264 Thursday, March 3, 2016 2:00 PM
Construcción y Materiales Aislantes: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Descripción
Datos de Carga de Aire
Techado
Tejas de asbesto/cemento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Asfalto (bitumen con relleno inerte). . . . . . . . . . . . . . . . . . . . . . . .
Rollos de asfalto para techo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tejas de asfalto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Techo armado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8 in.
Asfalto fundido (pesado, 20% arenilla) . . . . . . . . . . . . . . . . . . . . .
Paja de caña . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fieltro de techo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pizarra. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 in.
Paja . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tejas de madera, plano y película plástica . . . . . . . . . . . . . . . . . . .
Materiales de Enlucido
Enlucido de cemento, agregado de arena . . . . . . . . . . . . . . . . . . . .
Agregado de arena . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8 in.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 in.
Enlucido de yeso. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Agregado liviano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 in.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/8 in.
en malla de metal . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 in.
Agregado perlita . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Agregado arena. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
en malla de metal . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 in.
Agregado de vermiculita . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Yeso perlita. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Teja de barro, hueco
1 célula profunda . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 in.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 in.
2 células profundas . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 in.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 in.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 in.
3 células profundas . . . . . . . . . . . . . . . . . . . . . . . . . . 12 in.
Ladrillo liviano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bloques de hormigónf, g
Calizo agregado
Hormigón 8 pulg., 36 lb, 138 lb/pie3, 2 núcleos . . . . . . . . .
Con perlita-núcleos llenos . . . . . . . . . . . . . . . . . . . . . . . . . .
Hormigón, 12 pulg., 55 lb, 138 lb/pie3, 2 núcleos. . . . . . . .
Con perlita-núcleos llenos . . . . . . . . . . . . . . . . . . . . . . . . . .
Resistencia
Calor
Conductividadb
R,
Específico
k,
2
cp,
2·°F h·pie ·°F/
Btu·in/h·pie
Btu
Btu/lb·°F
120
100
119
144
70
70
70
59
17
141
—
15
—
—
2.98
4.0
7.97
—
—
—
1.32
0.62
8.32
—
0.49
—
0.21
—
—
—
0.15
0.44
0.33
—
—
—
0.05
—
0.94
0.24
—
—
—
0.36
0.3
0.35
—
—
—
0.3
—
0.31
116
—
—
70
80
45
45
—
45
105
—
30
40
45
50
60
25
38
38
98
90
97
5.0
—
—
2.63
3.19
—
—
—
1.5
5.6
—
1.0
1.39
1.7
1.8
2.08
0.55
1.32
0.48
4.4
3.33
4.5
—
0.08
0.15
—
—
0.32
0.39
0.47
—
—
0.13
—
—
—
—
—
—
—
—
—
—
—
0.2
0.2
0.2
—
—
—
—
—
0.32
0.2
—
—
—
—
—
—
—
—
—
—
—
—
150
140
130
120
110
100
90
80
70
8.4 a 10.2
7.4 a 9.0
6.4 a 7.8
5.6 a 6.8
4.9 a 5.9
4.2 a 5.1
3.6 a 4.3
3.0 a 3.7
2.5 a 3.1
—
—
—
—
—
—
—
—
—
—
—
—
0.19
—
—
—
—
—
—
—
—
—
—
—
50
48
—
—
—
—
—
—
1.39
1.51
0.80
1.11
1.52
1.85
2.22
2.50
—
—
0.21
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2.1
—
3.7
—
—
—
—
—
264
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tablero de pulpa o papel de yeso . . . . . . . . . . . . . . . . . . . . . . . . . .
Enlucido arena /cemento, condicionado. . . . . . . . . . . . . . . . . . . . .
Enlucido cal/cemento/arena, condicionado . . . . . . . . . . . . . . . . . .
Enlucido yeso/arena (3:1) condicionado . . . . . . . . . . . . . . . . . . . .
Materiales de Mampostería
Unidades de mampostería
Ladrillo, arcilla cocida
Densidad,
lb/pie3
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (I-P)
12.fm Page 265 Thursday, March 3, 2016 2:00 PM
Construcción y Materiales Aislantes: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Descripción
Densidad,
lb/pie3
Con perlita-núcleos llenos . . . . . . . . . . . . . . . . . . . . . . . . .
Con vermiculita-núcleos llenos . . . . . . . . . . . . . . . . . . . . .
Piedra, cal o arena . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cuarcítico y gres . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calcítica, dolomita, calizo, mármol y granito . . . . . . . . . . . . . . . .
Hormigonesi
Arena y gripio u hormigones agregados de piedra
(Hormigones con >50% arena cuarzosa o cuarcita tienen
conductividades en extremo más alto de margen)
Agregado liviano u hormigones de calizo
Esquisto expandido, arcilla o pizarra; escorias expandidas;
cenizas;
Piedra pómez (con densidad hasta100 lb/pie3); escoria
(hormigón enarenado tiene conductividades en extremo
más alto de margen)
Hormigón fibra de yeso (87.5% yeso, 12.5% virutas de madera) . . .
Cemento/cal, mortero y estuco . . . . . . . . . . . . . . . . . . . . . . . . . . .
Perlita, vermiculita y perlas de poliestireno . . . . . . . . . . . . . . . . .
Hormigones de espuma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.11 a 0.97
0.22
—
—
—
2.0
1.92 a 1.37
1.23
—
—
0.22
—
1.71 a 1.28
—
—
—
—
—
3.7 a 2.3
3.3
3.2
2.7
—
—
—
—
—
1.93 a 1.65
—
—
—
—
—
—
—
—
—
4.2
3.0
3.2 a 1.90
6.8 a 4.4
5.3 a 3.9
4.8
4.5
3.5
—
—
0.21
—
—
—
—
—
—
2.6 a 2.3
—
—
—
180
160
140
120
180
160
140
120
100
—
—
72
43
24
13
30
22
16
11
8
9.2 a 6.3
5.8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.19
—
—
—
0.19
—
—
—
—
150
163
—
—
—
3.95
6.45
1.26
1.35
1.67
—
—
0.19
—
—
0.2
0.2
150
140
130
120
10.0 a 20.0
9.0 a 18.0
7.0 a 13.0
6.4 a 9.1
—
—
—
—
—
0.19 a 0.24
—
—
100
4.7 a 6.2
—
0.2
80
60
40
51
120
100
80
50
3.3 a 4.1
2.1 a 2.5
1.3
1.66
9.7
6.7
4.5
1.8 a 1.9
—
—
—
—
—
—
—
—
0.2
—
—
0.2
—
—
—
—
40
1.4 a 1.5
—
0.15 a 0.23
30
1.1
—
—
20
0.8
—
—
120
5.4
—
—
100
4.1
—
—
80
3.0
—
—
70
2.5
—
—
265
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Azulejo, partición de yeso
3 por 12 por 30 pulg., solido. . . . . . . . . . . . . . . . . . . . . . . .
4 células . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 por 12 por 30 pulg., 3 células . . . . . . . . . . . . . . . . . . . . .
Calizo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Datos de Carga de Aire
Normal-peso agregado (arena y gripio)
Hormigón 8 pulg., 33 a 36 lb, 126 a 136 lb/pie3,
—
2 ó 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con perlita-núcleos llenos
—
Con vermiculita-núcleos llenos
—
Hormigón 12 pulg., 50 lb, 125 lb/pie3, 2 núcleos
—
Medio-peso agregado (combinaciones de agregado normal y ligero)
3
Hormigón 8 pulg., 26 a 29 lb, 97 a 112 lb/pie ,
—
2 ó 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con perlita-núcleos llenos . . . . . . . . . . . . . . . . . . . . . . . . .
—
Con vermiculita-núcleos llenos . . . . . . . . . . . . . . . . . . . . .
—
Con moldeado EPS-núcleos (perlas) llenos . . . . . . . . . . . .
—
Con moldeado EPS insertos en los núcleos . . . . . . . . . . . .
—
Agregado ligero (esquisto expandido, arcilla, pizarra o escoria, piedra pómez)
Hormigón 6 pulg., 16 a 17 lb, 85 a 87 lb/pie3,
—
2 ó 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con perlita-núcleo lleno . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Con vermiculita-núcleos llenos . . . . . . . . . . . . . . . . . .
—
Hormigón 8 pulg., 19 a 22 lb, 72 a 86 lb/pie3 . . . . . . . . . .
—
Con perlita-núcleos llenos . . . . . . . . . . . . . . . . . . . . . . . . .
—
Con vermiculita-núcleos llenos . . . . . . . . . . . . . . . . . . . . .
—
Con moldeado-EPS-núcleos (perlas) llenos . . . . . . . . . . . .
—
Con espuma UF-núcleos llenos . . . . . . . . . . . . . . . . . . . . .
—
Con EPS moldeados insertados en núcleos . . . . . . . . . . . .
—
Hormigón 12 pulg., 32 a 36 lb, 80 a 90 lb/pie3,
—
2 ó 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Resistencia
Calor
Conductividadb
R,
Específico
k,
2
cp,
2·°F h·pie ·°F/
Btu·in/h·pie
Btu
Btu/lb·°F
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (I-P)
12.fm Page 266 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
Construcción y Materiales Aislantes: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Resistencia
Calor
Conductividadb
R,
Específico
k,
2
cp,
2·°F h·pie ·°F/
Btu·in/h·pie
Btu
Btu/lb·°F
Descripción
Densidad,
lb/pie3
Hormigones de espumas y hormigones celulares. . . . . . . . . . . . . .
60
2.1
—
—
40
1.4
—
—
20
0.8
—
—
Hormigón aireado (secado al horno) . . . . . . . . . . . . . . . . . . . . . . .
Hormigón poliestireno (secado al horno) . . . . . . . . . . . . . . . . . . . .
Hormigón polímero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 a 50
16 a 50
122
1.4
2.54
11.4
—
—
—
0.2
0.2
—
138
7.14
—
—
Cemento polímero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hormigón escoria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
117
60
5.39
1.5
—
—
—
—
Maderas (12% contenido de humedad)j
Maderas duras
Roble . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Abedul . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Arce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ceniza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maderas blandas
Pino del sur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pino amarillo del sur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pino blanco del este . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Douglas abeto/alerce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ciprés del sur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Abeto/dobladillo, picea/pino/abeto . . . . . . . . . . . . . . . . . . .
Picea. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cedro rojo del oeste . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maderas de la costa oeste, cedros . . . . . . . . . . . . . . . . . . . .
Cedro blanco del este. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Secoya de California . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pino (secado al horno) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Picea
80
2.25
—
—
100
3
—
—
125
8.53
—
—
—
41 a 47
43 45
40 a 44
38 a 42
—
36 s 41
31
25
34 a 36
31 a 32
24 a 31
25
22
22 a 31
23
24 a 28
23
25
—
1.12 a 1.25
1.16 a 1.22
1.09 a 1.19
1.06 a 1.14
—
1.00 s 1.12
1.06 a 1.16
0.85 a 0.94
0.95 a 1.01
0.90 a 0.92
0.74 a 0.90
0.74 a 0.85
0.83 a 0.86
0.68 a 0.90
0.82 a 0.89
0.74 a 0.82
0.64
0.69
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.39k
—
—
—
—
0.39k
—
—
—
—
—
—
—
—
—
—
—
0.45
0.45
Notas para la Tabla 12.8
a
d
e
f
g
h
i
j
 1.874  10 + 5.753  10 M 
k = 0.1791 + -------------------------------------------------------------------------------1 + 0.01M
–2
k
–4
donde  es la densidad de la madera húmeda en lb/ft3, y M es el contenido de la humedad en porcentaje.
De Wilkes (1979), una ecuación empírica para calor específico de madera húmeda a 75°F es como sigue:
 0.299 + 0.01 M 
c p = ----------------------------------------- + c p
 1 + 0.01 M 
donde cp y representa el calor de sorción y se denota por
c p = M 1.921  10

–3
– 3.168  10
–5
M

donde M es el contenido de humedad en porcentaje por masa.
266
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
b
c
Los valores son para temperatura media de 75°F. Los valores representativos para materiales secos se pretenden que sean valores de diseño (no
especificación) para materiales en uso normal. Valores térmicos de materiales aislantes pueden diferir de los valores de diseño dependiendo de
los valores in-situ (ej. contenido de humedad y densidad, orientación, etc.) y variabilidad de fabricación. Para propiedades de un producto
específico, utilice valores suministrados por el fabricante o pruebas imparciales.
El símbolo  también utilizado para representar conductividad térmica.
No incluye soporte de papel y revestimiento, si los hay. Donde el aislamiento forma límites del espacio de aire (reflectante o lo contrario) ver
Tablas 12.2 y 12.3 para valores de aislamiento de espacio de aire con emitancia efectiva apropiada y condiciones de temperatura de espacio.
La conductividad varía con el diámetro de la fibra (ver Capítulo 25). Bloque de fibra, manta y aislamientos de fibra mineral sueltos son fabricados para
alcanzar valores R especificados, los más comunes de los cuales están indicados en la tabla. Debido a las diferencias en los procesos de fabricación y
materiales, el espesor del producto, densidades y condiciones térmicas varían sobre las considerables gamas para un valor específico R.
Los valores de aislamiento de la loseta acústica varían, dependiendo en la densidad del tablero y en el tipo, tamaño y profundidad de las perforaciones.
Los valores de bloques totalmente rellenos de cemento pueden ser aproximados utilizando valores para hormigón con la densidad de unidad similar.
Los valores para bloques de hormigón y concreto son representativos de contenido de humedad de uso normal.
Los valores para revestimiento de vinilo o metal aplicados sobre las superficies planas varían ampliamente, dependiendo de la ventilación del
espacio de aire debajo del revestimiento, si el espacio de aire es reflectante o no reflectante y en el espesor, tipo y aplicación de aislante en el
tablero de respaldo utilizado. Los valores son promedios para uso como guías de diseño y fueron obtenidos de muchas pruebas de caja caliente
con guarda (Norma ASTM C1363) en tipos huecos respaldados y tipos hechos utilizando respaldo de fibra de maderas, plástico espumado y
fibra de vidrio. Desvío de ± 50% o más de estos valores puede ocurrir.
Calor específico de vinilo = 0.25 Btu/lb·°F.
Ver Adams (1971), MacLean (1941), y Wilkes (1979). Los valores de conductividad indicados son para transferencia de calor a través del
grano. La conductividad térmica varía de forma lineal con la densidad y los márgenes de densidad indicados son aquellos normalmente encontrados para las especies de madera dadas, .Si la densidad de las especies de madera no es conocida, utilice los valores medios de conductividad.
Para extrapolación a otros contenidos de humedad, la siguiente ecuación empírica desarrollada por Wilkes (1979) puede ser utilizada:
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (I-P)
12.fm Page 267 Thursday, March 3, 2016 2:00 PM
Materiales de Construcción y Asilamiento: Valores de Diseñoa
[2013F, Ch 26, Tbl 1]
Descripción
Densidad,
kg/m3
Calor
Conductividadb Resistencia
Específico
k,
R,
cp,
2·K)/W
W/(m·K)
(m
kJ/(kg·K)
Materiales Aislantes
Mantas y bloquesc,d
Bloques de fibra de vidrio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Roca y bloques, lana de escoria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Caucho expandido (rígido) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Poliestireno extruido, piel suave . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Envejecido por Can/ULC Norma S770-2003 . . . . . . . . . . . . . .
Envejecido 180 días . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Producto Europeo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Envejecido 5 años a 24°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Soplado con potencial de calentamiento global (GWP) (<5)
agente de expansión . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Poliestirreno expandido, perlas moldeadas
Fibra de vidriod
áticos, ~100 a 600 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
áticos, ~600 a 1100 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ático cerrado o cavidades de pared . . . . . . . . . . . . . . . . . . . . . .
Roca y escoriasd
áticos, ~90 a 115 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
áticos, ~125 a 430 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ático cerrado o cavidades de pared . . . . . . . . . . . . . . . . . . . . . .
Vermiculita, exfoliada
Rociador aplicado
Celulosa, rociada en las cavidades de pared abiertas . . . . . . . .
Fibra de vidrio, rociada en paredes abiertas o cavidades del
ático . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Espuma de poliuretano
Densidad baja, célula abierta. . . . . . . . . . . . . . . . . . . . . . . . . . .
Densidad media, célula cerrada, envejecido 180 días. . . . . . . .
—
—
—
—
—
—
—
—
—
0.8
—
—
—
—
0.8
—
—
—
—
0.8
120
0.042
—
400 a 430
0.072 a 0.076
—
—
350
—
24 a 96
64
—
22 a 58
22 a 58
30
32 a 35
0.082
—
0.033 a 0.035
0.029
—
0.026 a 0.029
0.029
0.030
0030
—
—
—
—
—
—
1.3
0.8
—
1.7
1.5
—
—
—
0.035 a 0.036
—
—
—
16 a 24
29
160
—
64 a 130
160 a 180.
340 a 370
140
—
26 a 37
—
—
—
0.035 a 0.037
0.033
0.037
—
0.033 a 0.036
0.039 a 0.042
0.052 a 0.053
0.052
—
0.023 a 0.025
0.022 a 0.023
0.020 a 0.023
—
—
—
—
—
—
—
—
—
—
—
—
—
1.5
—
—
0.8
0.8
—
0.8
0.6 a 0.8
—
1.5
—
—
—
—
16 a 19
19 a 26
56
32 a 64
64 a 120
120 a 180
—
0.045 a 0.046
0.039 a 0.040
0.039 a 0.040
0.039 a 0.045
0.045 a 0.052
0.052 a 0.061
—
—
—
—
—
—
—
1.4
—
—
—
1.1
—
—
6.4 a 8.0
8 a 9.6
29 a 37
0.052 a 0.055
0.049 a 0.052
0.035 a 0.036
—
—
—
—
—
—
24 a 26
24 a 29
64
112 a 131
64 a 96
0.049
0.046 a 0.048
0.039 a 0.042
0.068
0.063
—
—
—
—
—
—
—
—
1.3
—
26 a 42
0.039 a 0.040
—
—
16
0.039 a 0.042
—
—
29 a 37
—
7.2 a 10
30 a 51
0.033 a 0.037
—
0.037 a 0.042
0.020 a 0.029
—
—
—
—
—
1.5
—
—
267
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tablero de fibra mineral, fieltro mojado . . . . . . . . . . . . . . . . . . . . . . .
Tablero de lana de roca . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pisos y paredes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Techo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Loseta acústicae . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tablero de perlita . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Poliisoianurato . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sin revestir envejecido por Can/ULC Norma S770-2003 . . . . . .
Con recubrimiento de aluminio, envejecido 180 días. . . . . . . .
Tablero de espuma fenólica con facers, envejecido
Relleno Suelto
Fibra de celulosa, relleno suelto
Aplicación de ático hasta 100 mm . . . . . . . . . . . . . . . . . . . . . .
Aplicación de ático > 100 mm . . . . . . . . . . . . . . . . . . . . . . . . .
Aplicación de pared, denso lleno . . . . . . . . . . . . . . . . . . . . . . .
Perlita, expandido
0.046 a 0.048
0.040 a 0.043
0.037 a 0.039
0.033
—
0.036 a 0.037
0.033 a 0.035
0.040
0.035
Datos de Carga de Aire
Lana mineral, fieltro. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tablero y losas
Vidrio celular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Losas de fibra de cemento, madera triturad con cemento Portland
aglomerado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
con oxysulfido de magnesia . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tablero de fibra de vidrio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.5 a 8.2
9.8 a 12
13 a 14
22
—
32 a 37
45
16 a 48
16 a 130
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (SI)
12.fm Page 268 Thursday, March 3, 2016 2:00 PM
Materiales de Construcción y Asilamiento: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Descripción
Datos de Carga de Aire
Panel de Construcción y Revestimiento
Panel
Panel de cemento/asbesto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Panel de cemento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fibra/panel de cemento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Yeso o panel de yeso. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Panel de fibra orientada (OSB) . . . . . . . . . . . . . . . . . . . . . . 9 a 11 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.7 mm
Madera contrachapada (abeto douglas) . . . . . . . . . . . . . . . . . 12.7 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.9 mm
Madera contrachapada/panel de madera . . . . . . . . . . . . . . . . . 19.0 mm
Panel de fibra vegetal
Revestimiento, densidad regular . . . . . . . . . . . . . . . . . 12.7 mm
Densidad intermedia . . . . . . . . . . . . . . . . . . . . . . . 12.7 mm
Revestimiento a base de clavo . . . . . . . . . . . . . . . . . . . 12.7 mm
Respaldo de tejas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.5 mm
Tablero de insonorización . . . . . . . . . . . . . . . . . . . . . . 12.7 mm
Paneles de azulejo, plano o acústico . . . . . . . . . . . . . . . . . . . . .
Laminado de cartón . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tablero homogéneo de papel de pulpa. . . . . . . . . . . . . . . . . . . .
Madera prensada
Densidad media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alta
densidad,
servicio
. . . . grado
. . . . . de
. . .servicio
. . . . . . templado
. . . . . . . .y. grado
. . . . . de
.......
Densidad,
kg/m3
1900
1150
1400
1000
400
300
640
650
650
460
540
450
650
290
350
400
290
240
290
480
480
0.57
0.25
0.25
0.19
0.07
0.06
0.16
—
—
—
—
—
—
—
—
—
—
—
0.058
0.072
0.072
—
—
—
—
—
—
—
0.11
0.12
0.14
0.15
0.19
0.11
0.23
0.19
0.19
0.17
0.24
—
—
—
1.00
0.84
0.84
0.84
1.88
1.88
1.15
1.88
1.88
1.88
1.88
1.88
1.88
1.30
1.30
1.30
1.30
1.26
0.59
1.38
1.17
0.105
0.12
0.144
—
—
—
1.30
1.34
1.34
0.102
0.135
1.18
—
0.072
—
—
—
1.22
—
1.30
1.30
—
1.21
1.88
—
—
—
—
0.037
0.15
0.21
0.25
—
—
—
—
—
0.037
0.026
0.26
—
0.14
—
1.30
1.17
1.30
—
1.01
1.47
1.47
0.12
1.17
—
—
—
—
—
—
1.0
0.14
0.18
0.10
—
0.11
0.32
0.52
—
1.22i
1.34
—
0.84
—
—
—
0.011
0.21
Inapreciable
—
—
—
—
—
—
—
0.40
—
—
0.42
0.12
0.28
0.09
—
0.06
0.014
—
—
—
—
—
—
0.80
1.17
1.17
1.22
268
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
800
880
Alta densidad, grado de templado estándar . . . . . . . . . . . . . . . .
1010
Aglomerado
Densidad baja . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
590
Densidad media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
800
Densidad alta . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1000
Contra-piso. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.9 mm
640
Tablero de plaqueta. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
700
Tejas
Asbesto/cemento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1900
Madera, 400 mm, 190 mm expuesto . . . . . . . . . . . . . . . . . . . . .
—
Madera, doble, 400 mm, 300 mm expuesto . . . . . . . . . . . . . . . .
—
Madera, más pulg. placa de cemento . . . . . . . . . . . . . . . . 8 mm
—
Revestimiento
Asbesto/cemento, recubierto . . . . . . . . . . . . . . . . . . . . . 6.4 mm
—
Recubrimiento rollo de asfalto . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Revestimiento aislante de asfalto (12.7 mm cama) . . . . . . . . . .
—
Revestimiento de madera prensada . . . . . . . . . . . . . . . . 11 mm
Madera, gota, 200 mm . . . . . . . . . . . . . . . . . . . . . . . . . . 25 mm
—
Madera, bisel
200 mm, recubierto . . . . . . . . . . . . . . . . . . . . . . . . . 13 mm
—
250 mm, recubierto . . . . . . . . . . . . . . . . . . . . . . . . . 19 mm
—
Madera, madera contrachapada, recubierta 9.5mm . . . . . . . . . .
—
Aluminio, acero o vinilo,h, i sobre revestimiento
Hueco respaldado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Panel aislado-respaldado . . . . . . . . . . . . . . . . . . . . . 9.5 mm
—
Papel aluminio-respaldado . . . . . . . . . . . . . . . . . . . 9.5 mm
—
Vidrio arquitectónico (8oda, flotador de cal). . . . . . . . . . . . . . .
2500
Membrana de Edificio
Vapor – fieltro permeable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Vapor: sello, 2 capas de fieltro de fregado 0.73 kg/m2 . . . . . . . . . . . .
—
Vapor: sello, película plástica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Materiales de Acabado de Piso
Alfombra y almohadilla de uretano rebotado . . . . . . . . . . . . . . 19 mm
110
Alfombra y almohadilla de caucho . . . . . . . . . . . . . . . . . . . . . . 9.5 mm
320
Alfombra de pelo con almohadilla de caucho. . . . . . . . 9.5 a 12.7 mm
290
Linóleo/baldosas de caucho . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4 mm
465
Recubrimiento de piso de caucho/PVC . . . . . . . . . . . . . . . . . . . . . . . .
—
Baldosas de caucho . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 mm
1900
terrazzo. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 mm
—
Metales (Ver Capítulo 33, Tabla 3 en el Manual Fundamentales de ASHRAE 2013)
Calor
Conductividadb Resistencia
Específico
k,
R,
cp,
2·K)/W
W/(m·K)
(m
kJ/(kg·K)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (SI)
12.fm Page 269 Thursday, March 3, 2016 2:00 PM
Materiales de Construcción y Asilamiento: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Descripción
Techado
Tejas de asbesto/cemento. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Asfalto (bitumen con relleno inerte) . . . . . . . . . . . . . . . . . . . . . . . . . .
Agregado liviano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 mm
En malla de metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 mm
Agregado de perlita . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Agregado de arena . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
En malla de metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 mm
Agregado de Vermiculita. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enlucido de perlita . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Teja de barro, hueco
1 célula profunda. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 mm
2 células profundas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 mm
3 células profundas . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 mm
Ladrillo liviano. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bloques de hormigónf, g
Calizo agregado
~200 mm, 16.3 kg, 2200 kg/m3 hormigón, 2 núcleos. . . . . . . .
Con núcleos de perlita llenos . . . . . . . . . . . . . . . . . . . . . . . . . .
~300 mm, 25 kg, 2200 kg/m3 hormigón, 2 núcleos. . . . . .
Con núcleos de perlita llenos . . . . . . . . . . . . . . . . . . . . . . .
1920
1600
1900
2300
920
920
920
950
270
2250
—
240
—
—
0.43
0.58
1.15
—
—
—
0.19
0.09
1.20
—
0.07
—
0.037
—
—
—
0.027
0.078
0.059
—
—
—
0.009
—
0.166
1.00
—
—
—
1.51
1.26
1.47
—
—
—
1.26
—
1.30
1860
—
—
1120
1280
—
720
1680
—
480
600
720
840
960
400
600
600
1560
1440
1550
0.72
—
—
0.38
0.46
720
720
—
0.22
0.81
—
0.14
0.20
0.25
0.26
0.30
0.08
0.19
0.07
0.63
0.48
0.65
—
0.013
0.026
—
—
—
—
0.083
—
—
0.023
—
—
—
—
—
—
—
—
—
—
—
0.84
0.84
0.84
—
—
0.056
0.066
—
1.34
0.84
—
—
—
—
—
—
—
—
—
—
—
—
2400
2240
2080
1920
1760
1600
1440
1280
1120
1.21 a 1.47
1.07 a 1.30
0.92 a 1.12
0.81 a 0.98
0.71 a 0.85
0.61 a 0.74
0.52 a 0.62
0.43 a 0.53
0.36 a 0.45
—
—
—
—
—
—
—
—
—
—
—
—
0.80
—
—
—
—
—
—
—
—
—
—
—
800
770
—
—
—
—
—
—
0.20
0.22
0.14
0.20
0.27
0.33
0.39
0.44
—
—
0.88
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.37
—
0.65
—
—
—
—
—
269
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tablero de pulpa, papel de yeso. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enlucido de arena/cemento, condicionado . . . . . . . . . . . . . . . . . . . . .
Enlucido de arena/cemento/cal, condicionado . . . . . . . . . . . . . . . . . .
Enlucido de arena/yeso (3:1), condicionado . . . . . . . . . . . . . . . . . . . .
Materiales de Mampostería
Unidades de mampostería
Ladrillo, arcilla cocida . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calor
Conductividadb Resistencia
Específico
k,
R,
cp,
2·K)/W
W/(m·K)
(m
kJ/(kg·K)
Datos de Carga de Aire
Rollos de asfalto para techo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tejas de asfalto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Techo armado. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mm
Asfalto fundido (pesado, 20% arenilla) . . . . . . . . . . . . . . . . . . . . . . .
Caña de paja. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fieltro de techo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
pizarra . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 mm
Paja. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tejas de madera, plano y película plástica. . . . . . . . . . . . . . . . . . . . . .
Materiales de Enlucido
Enlucido de cemento, agregar arena . . . . . . . . . . . . . . . . . . . . . . . . . .
Agregado de arena . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mm
Enlucido de yeso . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Densidad,
kg/m3
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (SI)
12.fm Page 270 Thursday, March 3, 2016 2:00 PM
Materiales de Construcción y Asilamiento: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Datos de Carga de Aire
Descripción
Densidad,
kg/m3
Peso normal agregado (arena y ripio)
~200 mm, 16 kg, 2100 kg/m3 hormigón,
—
2 ó 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con núcleos de perlita llenos . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Con núcleos de vermiculita llenos . . . . . . . . . . . . . . . . . . . . . . .
—
~300 mm, 22.7 kg, 2000 kg/m3 hormigón, 2 núcleos . . . . . . . .
—
Peso medio agregado (combinación de agregado liviano y normal)
~200 mm, 13 kg, 1550 a 1800 kg/m3 hormigón,
2 o 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con núcleos de perlita llenos . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
Con núcleos de vermiculita llenos . . . . . . . . . . . . . . . . . . . . . . .
—
Con EPS moldeados-núcleos llenos (perlas) . . . . . . . . . . . . . . .
—
Con EPS moldeados insertados en núcleos . . . . . . . . . . . . . . . .
—
Masa baja agregada (esquisto expandido , arcilla, pizarra o escoria, piedra pómez)
~150 mm, 7 1/2 kg, 1400 kg/m2 hormigón,
—
2 ó 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con núcleos de perlita llenos . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con núcleos de vermiculita llenos . . . . . . . . . . . . . . . . . . .
200 mm, 8 a 10 kg, 1150 a 1380 kg/m2 hormigón . . . . . . . . . .
Con núcleos de perlita llenos . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con núcleos de vermiculita llenos . . . . . . . . . . . . . . . . . . . . . . .
Con EPS moldeado – núcleos llenos (perlas) . . . . . . . . . . . . . .
Con espuma UF – núcleos llenos . . . . . . . . . . . . . . . . . . . . . . . .
Con EPS moldeado insertados en núcleos . . . . . . . . . . . . . . . . .
300 mm, 16 kg, 1400 kg/m3, hormigón,
2 o 3 núcleos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con núcleos de perlita llenos . . . . . . . . . . . . . . . . . . . . . . . . . . .
Con núcleos de vermiculita llenos . . . . . . . . . . . . . . . . . . . . . . .
Piedra, cal o arena . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cuarcita y arenisca . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calcítica, dolomita, calizo, mármol y granito . . . . . . . . . . . . . . . . . . .
Hormigonesi
Arena y gripio, o piedra agregado hormigón
(hormigón con >50% cuarzo o arena de cuarcito tienen
conductividades en extremo más alto de margen )
Masa baja agregada u hormigones de caliza
Esquisto expandido, arcilla o pizarra, escoria expandida; cenizas;
Piedra pómez (con densidad hasta 1600 lg/m2);
Escoria (hormigones enarenados tienen conductividades en
extremo más alto)
Hormigón fibra de yeso
(87.5% yeso, 12.5% virutas de madera) . . . . . . . . . . . . . . . . .
Cemento, cal, mortero y estuco. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Perlita, vermiculita, y perlas de poliestireno . . . . . . . . . . . . . . . . . . . .
Hormigones de espuma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
—
0.20 a 0.17
0.92
—
—
—
0.35
0.34 a 0.24
0.217
—
—
0.92
—
0.30 a 0.22
—
—
—
—
—
0.65 a 0.41
0.58
0.56
0.47
—
—
—
—
—
0.34 a 0.29
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.74
0.53
0.56 a 0.33
1.20 a 0.77
0.93 a 0.69
0.85
0.79
0.62
—
—
0.88
—
—
—
—
—
—
—
0.46 a 0.40
—
—
—
2880
2560
2240
1920
2880
2560
2240
1920
1600
—
—
10.4
6.2
3.46
1.88
4.33
3.17
2.31
1.59
1.15
1.6 a 1.1
1.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.88
—
—
—
0.88
—
—
—
—
2400
2600
—
—
—
0.57
0.93
0.222
0.238
0.294
—
—
0.79
—
—
0.84
0.84
2400
2240
2080
1920
1600
1280
960
640
1.4 a 2.9
1.3 a 2.6
1.0 a 1.9
0.9 a 1.3
0.68 a 0.89
0.48 a 0.59
0.30 a 0.36
0.18
—
—
—
—
—
—
—
—
—
0.80 a 1.00
—
—
0.84
0.84
—
—
800
0.24
—
0.84
1920
1600
1280
800
1.40
0.97
0.65
0.26 a 0.27
—
—
—
—
—
—
—
—
640
0.20 a 0.22
—
0.63 a 0.96
480
0.16
—
—
320
0.12
—
—
1920
1600
1280
1120
0.75
0.60
0.44
0.36
—
—
—
—
—
—
—
—
270
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Azulejo partición de yeso
75 por 300 por 760 mm, sólido . . . . . . . . . . . . . . . . . . . . . . . . .
4 células . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100 por 300 por 760 mm, 3 células . . . . . . . . . . . . . . . . . . . . . .
Calizo
Calor
Conductividadb Resistencia
Específico
k,
R,
cp,
2·K)/W
W/(m·K)
(m
kJ/(kg·K)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (SI)
12.fm Page 271 Thursday, March 3, 2016 2:00 PM
Materiales de Construcción y Asilamiento: Valores de Diseñoa
[2013F, Ch 26, Tbl 1] (Continuo)
Densidad,
kg/m3
Descripción
Hormigones de espuma y hormigones de celular . . . . . . . . . . . . . . . .
Hormigón aireado (secado en horno). . . . . . . . . . . . . . . . . . . . . . . . . .
Hormigón (secado en horno) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hormigón polímero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cemento polímero . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hormigón escoria. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
960
640
320
430 a 800
255 a 800
1950
2200
1870
960
1280
1600
2000
0.30
0.20
0.12
0.20
0.37
1.64
1.03
0.78
0.22
0.32
0.43
1.23
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.84
0.84
—
—
—
—
—
—
—
—
660 a 750
680 a 725
635 a 700
615 a 670
—
570 a 660
500
400
535 a 580
500 a 515
390 a 500
400
350
350 a 500
360
390 a 450
370
395
—
0.16 a 0.18
0.17 a 0.18
0.16 a 0.17
0.15 a 0.16
—
0.14 a 0.16
0.13
0.10
0.14 a 0.15
0.13
0.11 a 0.13
0.09
0.09
0.10 a 0.13
0.10
0.11 a 0.12
0.092
0.10
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.63k
—
—
—
—
1.63k
—
—
—
—
—
—
—
—
—
—
—
1.88
1.88
Datos de Carga de Aire
Maderas (12% contenido de humedad)j
Maderas duras
Robles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Abedul . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Arce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ceniza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maderas Suaves
Pino del sur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pino amarillo del sur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pino blanco del este. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Abeto Douglas/alerce . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ciprés del sur. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dobladillo/abeto, picea/pino/abeto . . . . . . . . . . . . . . . . . . . . . .
Picea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cedro rojo del oeste . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maderas de la Costa Oeste, cedros . . . . . . . . . . . . . . . . . . . . . .
Cedro blanco del este . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Secoya de California . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pino (secado en horno) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Picea (secado en horno) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calor
Conductividadb Resistencia
Específico
k,
R,
cp,
2·K)/W
W/(m·K)
(m
kJ/(kg·K)
Notas para la Tabla 12.8
a
d
e
f
g
h
i
j
 1.874  10 + 5.753  10 M 
k = 0.1791 + -------------------------------------------------------------------------------1 + 0.01 M
–2
k
–4
donde  es la densidad de la madera húmeda en kg/m3, y M es el contenido de la humedad en porcentaje.
De Wilkes (1979), una ecuación empírica para calor específico de madera húmeda a 24°C es como sigue::
 0.299 + 0.01 M 
c p = ----------------------------------------- + c p
 1 + 0.01M 
donde cp y representa el calor de sorción y se denota por
c p = M  1.921  10 – 3.168  10 M 
–3
–5
donde M es el contenido de humedad en porcentaje por masa.
271
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
b
c
Los valores son para temperatura media de 24°C. Los valores representativos para materiales secos se pretenden que sean valores de diseño (no
especificación) para materiales en uso normal. Valores térmicos de materiales aislantes pueden diferir de los valores de diseño dependiendo de
los valores in-situ (ej. contenido de humedad y densidad, orientación, etc.) y variabilidad de fabricación. Para propiedades de un producto específico, utilice valores suministrados por el fabricante o pruebas imparciales.
El símbolo  también utilizado para representar conductividad térmica.
No incluye soporte de papel y revestimiento, si los hay. Donde el aislamiento forma límites del espacio de aire (reflectante o lo contrario) ver
Tablas 12.2 y 12.3 para valores de aislamiento de espacio de aire con emitancia efectiva apropiada y condiciones de temperatura de espacio.
La conductividad varía con el diámetro de la fibra (ver Capítulo 25). Bloque de fibra, manta y aislamientos de fibra mineral sueltos son fabricados para alcanzar valores R especificados, los más comunes de los cuales están indicados en la tabla. Debido a las diferencias en los procesos
de fabricación y materiales, el espesor del producto, densidades y condiciones térmicas varían sobre las considerables gamas para un valor
específico R.
Los valores de aislamiento de la loseta acústica varían, dependiendo en la densidad del tablero y en el tipo, tamaño y profundidad de las perforaciones.
Los valores de bloques totalmente rellenos de cemento pueden ser aproximados utilizando valores para hormigón con la densidad de unidad
similar.
Los valores para bloques de hormigón y concreto son representativos de contenido de humedad de uso normal.
Los valores para revestimiento de vinilo o metal aplicados sobre las superficies planas varían ampliamente, dependiendo de la ventilación del
espacio de aire debajo del revestimiento, si el espacio de aire es reflectante o no reflectante y en el espesor, tipo y aplicación de aislante en el
tablero de respaldo utilizado. Los valores son promedios para uso como guías de diseño y fueron obtenidos de muchas pruebas de caja caliente
con guarda (Norma ASTM C1363) en tipos huecos respaldados y tipos hechos utilizando respaldo de fibra de maderas, plástico espumado y
fibra de vidrio. Desvío de ± 50% o más de estos valores puede ocurrir.
Calor específico de vinilo = 1.0 kJ/(kg·K).
Ver Adams (1971), MacLean (1941), y Wilkes (1979). Los valores de conductividad indicados son para transferencia de calor a través del
grano. La conductividad térmica varía de forma lineal con la densidad y los márgenes de densidad indicados son aquellos normalmente encontrados para las especies de madera dadas. Si la densidad de las especies de madera no es conocida, utilice los valores medios de conductividad.
Para extrapolación a otros contenidos de humedad, la siguiente ecuación empírica desarrollada por Wilkes (1979) puede ser utilizada:
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.8 (SI)
12.fm Page 272 Thursday, March 3, 2016 2:00 PM
Tabla 12.9 (I-P)
Datos de Carga de Aire
Techo
No.
1
2
3
4
5
8
9
10
13
14
2
–2
0
8
11
16
24
25
31
31
32
4
–5
–4
2
3
8
17
16
22
25
27
Tabla 12.10 (I-P)
Techo
No.
4
–5
–4
2
3
8
17
16
23
25
28
Tabla 12.11 (I-P)
Techo
No.
1
2
3
4
5
8
9
10
13
14
2
–2
0
8
12
16
24
26
31
30
32
4
–5
–4
2
3
8
17
16
22
25
27
6
–6
–6
–2
–2
3
11
9
15
20
23
8
9
1
3
–4
1
9
4
9
16
19
10
44
30
22
5
10
14
5
8
16
19
Tiempo solar, h
12
14
76
92
64
86
47
68
27
55
30
52
27
43
17
36
16
30
23
33
24
32
16
86
89
77
75
68
54
54
45
43
40
18
58
70
68
80
70
58
65
56
49
45
20
23
36
47
67
59
52
63
59
49
45
22
8
14
29
43
41
42
51
52
43
42
24
2
5
16
23
27
32
37
41
37
37
Diferencias de Temperatura de Carga de Refrigeración (CLTDs)
para Techos Planos – Latitud 36°N, Julio
6
–6
–6
–2
–1
3
12
9
15
20
23
8
12
4
4
–3
2
9
4
10
16
20
10
45
32
24
7
12
15
7
9
17
20
Tiempo solar, h
12
14
75
90
63
84
47
67
29
55
31
52
28
42
19
37
17
30
24
33
25
32
16
84
87
75
74
67
54
54
45
43
40
18
60
70
68
79
70
58
64
56
49
45
20
26
39
48
67
59
53
63
58
49
46
22
9
15
30
45
42
43
52
52
44
42
24
2
5
17
24
27
33
38
42
37
37
Diferencias de Temperatura e Carga de Refrigeración (CLTDs)
para Techos Planos — Latitud 48°N, Julio
6
–5
–5
–1
–1
3
11
9
15
20
23
8
15
6
6
–2
3
10
5
10
16
20
10
44
32
24
8
13
16
8
10
18
20
Tiempo solar, h
12
14
69
83
60
78
45
63
29
52
31
49
27
40
19
35
17
29
24
32
24
31
16
79
81
71
69
63
51
51
43
41
38
18
59
68
65
74
66
55
60
53
47
43
20
29
41
48
65
58
51
61
56
47
44
22
9
16
30
45
42
42
51
51
43
41
24
2
5
17
25
27
32
38
41
37
36
PRECAUCION: Datos aproximados—Utilizar sólo para cálculos preliminares. También, ver notas en la página siguiente.
272
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
1
2
3
4
5
8
9
10
13
14
2
–2
0
8
11
16
25
26
32
31
32
Diferencias de Temperatura de Carga de Refrigeración (CLTDs)
para Techos Planos—Latitud 24°N, Julio
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Diferencias de Temperatura de Carga de Refrigeración (CLTDs)
0
1
7
9
12
16
18
21
19
19
1
2
3
4
5
8
9
10
13
14
–1
0
4
6
9
13
14
18
17
18
2
–2
–1
3
4
7
12
12
15
16
17
3
Tabla 12.9 (SI)
–3
–2
1
2
4
9
9
13
14
15
4
–3
–3
0
1
3
8
7
11
12
14
5
–3
–3
–1
–1
2
7
5
8
11
13
6
0
–2
0
–2
1
6
3
7
10
12
7
7
2
3
–2
1
6
2
6
9
11
8
16
9
7
0
3
7
2
5
9
11
9
25
18
13
4
7
9
4
6
9
11
10
33
27
19
9
12
12
7
7
11
12
11
41
34
26
16
17
16
11
9
13
13
46
41
32
23
23
19
15
13
16
16
49
46
37
30
28
23
20
17
18
18
Tiempo solar, h
12
13
14
49
48
40
36
33
27
25
21
21
20
15
46
47
41
41
37
29
29
24
23
22
16
41
44
41
43
38
31
33
28
26
23
17
33
39
37
43
38
32
35
31
27
24
18
24
31
33
41
36
31
36
32
27
25
19
14
22
27
37
33
29
35
32
27
25
20
8
14
21
31
28
27
32
31
26
24
21
5
8
17
25
23
24
29
29
24
23
22
Diferencias de Temperatura de Carga de Refrigeración (CLTDs) para Techos Planos—Latitud 40°N, Julio
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
PRECAUCION: Datos aproximados – Utilizar sólo para cálculos preliminares. También, ver notas en la página siguiente.
1
Techo
No.
12.fm Page 273 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
273
3
5
13
19
19
21
25
26
22
22
23
1
3
9
13
15
18
21
23
21
21
24
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
12.fm Page 274 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
Corr. CLTD = CLTD + (78  tr) + (tm  85)
(I-P)
Corr. CLTD = CLTD + (25.5  tr) + (tm  25.5)
(SI)
donde tr = temperatura interior y tm = temperatura exterior media, o tm = temperatura
exterior máxima  (margen diario)/2.
Ningún ajuste recomendado para color o para ventilación de espacio de aire encima de un
techo.
Para propósitos de diseño, los datos son suficientes para más o menos 2 semanas desde el 21
día del mes determinado.
Tabla 12.12
Clasificaciones de Techo para Utilizar con Tablas CLTD
para Techos Planos
Ubicación
Techo
de Masas Suspendido
Sin
Masa
interior
aislante
Sin
Masa
uniformemente
colocada
Con
Sin
Masa
exterior
aislante
Con
Hormigón
(Pesado)
Madera
Techo del
2 pulg.
Cubierta
1 pulg.
Ático
(Hormigón de Acero
(25 mm)
Comb.
Duro
50 mm)
0 a 10 (0 a 1.76)
10 a 20 (1.76 a 3.52)
20 a 25 (3.52 a 4.40)
0 a 5 (0 a 0.88)
5 a 10 (0.88 a 1.76)
10 a 20 (1.76 a 3.52)
20 a 25 (3.52 a 4.40)
*
*
*
*
*
*
*
2
4
5
5
8
13
14
*
*
*
*
*
*
*
*
*
*
*
*
*
*
0 a 5 (0 a 0.88)
1
2
1
1
5 a 15 (0.88 a 2.64)
15 a 25 (2.64 a 4.40)
0 a 5 (0 a 0.88)
5 a 10 (0.88 a 1.76)
10 a 15 (1.76 a 2.64)
15 a 20 (2.64 a 3.52)
20 a 25 (3.52 a 4.40)
0 a 5 (0 a 0.88)
5 a 10 (0.88 a 1.76)
10 a 15 (1.76 a 2.64)
15 a 25 (2.64 a 4.40)
0 a 10 (0 a 1.76)
10 a 15 (1.76 a 2.64)
15 a 20 (2.64 a 3.52)
2
4
*
4
5
9
10
*
*
*
*
*
*
*
*
*
3
*
*
*
*
2
3
4
5
3
4
5
1
2
1
1
2
2
4
*
*
*
*
*
*
*
2
2
*
*
*
*
*
*
*
*
*
*
*
*Denota techo que no es posible con los parámetros elegidos.
274
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Con
R,
h·pie2·°F/Btu
2
(m ·K/W)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Notas para Datos de CLTD para Tejados Planos
1. Los datos aplican directamente a (1) superficie oscura, (2) la temperatura interna es 78°F
(25.5°C), (3) la temperatura máxima exterior de 95°F (35°C) con temperatura media de
85°F (29.4°C) y margen diario de 21°F (11.6°C), (4) la radiación solar típica de un día
claro en el 21 día del mes, (5) resistencia de película de superficie exterior de
0.333 h·pie2·°F/Btu (0.059 m2·K/W), y (6) resistencia de la superficie interior de
0.685 h·pie2·°F/Btu (0.121 m2·K/W).
2. Ajustes a las temperaturas de diseño
12.fm Page 275 Thursday, March 3, 2016 2:00 PM
Cara
Tiempo Solar, h
a la
Pared 6 8 10 12 14 16 18 20 6
Tiempo Solar, h
8 10 12 14 16 18 20
Tiempo Solar, h
6
8
10 12 14 16 18 20
Masa Baja, Pared Valor-R Bajo Masa Baja, Pared Valor-R Medio Masa Baja, Pared Valor-R Alto
N
–2 13 18 22 28 32 34 17 1
0
6 13 18 23 28 30 –2
2
12 18 23 28 32 29
NE
0 39 53 39 30 30 24 13 0
3 20 36 39 35 32 27 –2
9
36 46 38 32 29 22
E
0 44 63 48 32 30 24 13 1
3 22 43 46 40 34 28 –2 10 42 55 44 35 30 23
SE
–2 25 44 42 32 30 24 13 0
1 13 28 35 35 32 27 –2
S
–3 3 12 24 31 30 23 13 0 –1 1
7 16 24 27 25 –2 –1
4
13 24 29 28 22
SO –3 3 13 22 40 58 52 20 1 –1 1
7 15 29 43 47 –2 –1
5
13 24 42 54 44
26 40 38 33 29 22
–3 3 13 22 42 73 75 27 2
0
2
7 15 30 52 61 –1 –1
5
13 23 46 69 61
NO –3 3 13 22 37 62 67 25 1
0
2
7 15 27 45 54 –1 –1
5
13 22 40 60 55
Masa Alta, Pared Valor-R Bajo Masa Alta, Pared Valor-R Medio Masa Alta, Pared Valor-R Alto
N
3 3
NE
3 6 20 31 33 32 31 27 11 9 14 21 25 26 27 26 13 10 10 15 21 24 27 27
7 12 16 21 25 27 10 8
8 10 12 15 18 21 12
9
8
8
10 13 16 19
E
4 6 22 36 39 36 33 29 12 10 15 24 29 30 30 29 14 11 11 17 24 28 30 31
SE
3 4 14 25 30 30 30 26 10 8 11 17 21 24 25 25 13 10
9
S
3 1
3
7 14 20 23 22 8
6
5
7
10 14 17
SO
5 3
4
8 14 26 38 40 13 10 9
9 11 17 24 30 17 13 10
8
9
12 18 25
6
5
6 10 14 17 18 10
8
12 17 21 24 25
O
7 4
4
8 15 28 45 51 17 13 11 11 13 18 28 36 21 16 12 10 11 13 20 30
NO
6 3
4
8 14 25 40 46 15 12 10 10 12 17 25 32 19 14 11
9
10 12 18 26
PRECAUCION: Datos aproximados. Utilizar sólo para cálculos preliminares.
Tabla 12.14 (I-P) Diferencias de Temperatura de Carga de Refrigeración (CLTDs) Aproximadas
para Paredes Iluminadas por Luz Solar—Latitud 36°N, Julio
Cara
a la
Pared 6
Tiempo Solar, h
8 10 12 14 16 18 20 6
Tiempo Solar, h
8
10 12 14 16 18 20 6
Tiempo Solar, h
8 10 12 14 16 18 20
–1 12 14 21 28 29 30 17 0
0
5
NE
1 41 46 30 29 29 24 14 0
4
21 33 33 31 30 27 –2 12 36 39 32 30 28 23
10 16 22 26 27 –2 3
9 15 21 27 28 27
E
1 49 64 48 31 30 24 14 1
4
26 45 47 40 34 29 –2 14 46 56 45 34 30 23
SE
–1 31 52 52 36 30 24 14 1
2
16 34 44 41 35 29 –2 7 31 48 47 37 31 23
S
–3 4 18 39 47 40 25 14 0
–1
2
SO
–2 4 13 23 50 67 59 23 1
0
2
8
17 34 51 54 –1 –1 5 13 28 50 62 51
O
–2 4 13 21 42 73 78 31 2
0
2
8
15 30 52 63 –1 –1 5 13 23 46 69 65
–2 4 13 21 29 53 65 28 1
0
2
8
15 24 39 51 –2 –1 5 13 21 33 53 55
NO
11 25 36 38 32 –2 –1 6 21 37 44 37 25
Masa Alta, Pared Valor-R Bajo Masa Alta, Pared Valor-R Medio Masa Alta, Pared Valor-R Alto
N
3
3
6 10 15 20 23 25 9
7
8
NE
3
7 20 28 29 29 29 26 10
9
14 20 23 24 25 25 13 10 10 15 19 22 24 25
9
11 14 17 19 11 9
7
7
9 11 14 17
8 25 38 40 37 34 29 12 11 17 25 30 31 31 30 15 11 12 18 25 30 31 31
E
4
SE
4
5 17 30 37 36 33 29 12 10 13 20 26 29 29 28 14 11 10 14 20 26 29 30
S
3
2
4 11 22 31 33 29 10
SO
6
3
4
8
7
9
14 20 24 25 13 10 7
7 10 15 21 24
8 16 31 44 46 15 12 10 10 13 19 28 34 19 15 11 10 10 14 21 29
O
7
4
5
9 15 28 46 54 17 14 12 11 13 18 28 37 22 17 13 11 11 14 20 30
NO
6
3
4
8 14 22 35 43 14 11 10 10 12 15 22 30 18 14 11 9 10 12 17 24
PRECAUCION: Datos aproximados – Utilizar sólo para cálculos preliminares.
275
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Masa Baja, Pared Valor-R Bajo Masa Baja, Pared Valor-R Medio Masa Baja, Pared Valor-R Alto
N
Datos de Carga de Aire
O
4
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.13 (I-P) Diferencias de Temperatura de Carga de Refrigeración (CLTDs) Aproximadas
para Paredes Iluminadas por Luz Solar—Latitud 24°N, Julio
12.fm Page 276 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
Cara
Tiempo Solar, h
a la
Pared 6 8 10 12 14 16 18 20
Masa Baja, Pared Valor-R Bajo
N
3 10 13 21 27 28 27 21
NE 10 42 38 26 28 29 24 15
E 10 54 64 47 31 29 25 15
SE 4 36 59 61 45 31 25 15
S –2 5 28 52 62 51 29 15
SO –1 5 12 29 59 75 65 29
O –1 5 13 21 41 72 80 41
NO –2 5 12 21 27 45 62 37
Masa Alta, Pared Valor-R Bajo
N
3 4 6 10 14 19 22 24
NE 4 10 22 26 26 27 27 25
E
4 11 28 40 40 37 34 29
SE 4 7 20 35 43 42 38 32
S
5 3 6 16 31 41 43 37
SO 7 4 5 9 19 36 50 52
O
8 5 6 9 15 27 45 55
NO 6 4 5 8 14 20 31 41
Tiempo Solar, h
6
8
Tiempo Solar, h
10 12 14 16 18 20 6
Masa Baja, Pared Valor-R Medio
1 2 6 10 16 21 25 26
1 7 23 31 30 29 28 26
1 8 30 47 48 40 34 29
1 4 20 40 51 49 40 32
1 0 3 16 34 48 50 40
2 0 3 8 20 40 58 61
2 0 3 8 15 29 51 64
2 0 2 8 14 22 34 47
Masa Alta, Pared Valor-R Medio
9 8 8 9 11 14 17 19
10 10 15 20 22 23 24 24
12 12 19 27 32 32 32 30
13 12 15 23 30 34 34 32
13 10 9 12 19 27 32 33
18 14 12 12 15 23 32 39
19 15 12 12 14 19 28 38
14 11 10 10 12 15 20 28
8 10 12 14 16 18 20
Masa Baja, Pared Valor-R Alto
–1 5 9 14 21 26 27 27
0 18 36 34 28 28 28 23
0 20 49 57 44 34 29 23
–1 11 36 55 56 43 33 24
–1 0 9 30 50 57 47 30
–1 0 6 14 33 58 69 57
–1 0 6 13 22 45 69 69
–1 0 5 13 20 29 46 54
Masa Alta, Pared Valor-R Alto
12 9 8 8 9 11 14 17
13 10 12 16 19 22 23 24
15 12 14 20 27 31 32 32
16 12 12 17 24 30 34 34
16 12 10 10 14 21 28 32
22 17 13 11 12 16 24 33
23 18 14 12 12 14 20 30
18 14 11 9 10 12 16 22
276
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota 1. Aplicar datos directamente a (1) superficie oscura, (2) temperatura interior de 78°F, (3) temperatura máxima exterior
de 95°F con temperatura media de 85°F y margen diario de 21°F, (4) resistencia de película de superficie exterior de 0.333
(h·pie2·°F)/Btu, y (5) resistencia de superficie interior de 0.685 (h·pie2·°F)/Btu.
Nota 2. Ajustes a temperaturas de diseño:
Corr. CLTD = CLTD + (78  tr) + (tm  85)
donde tr = temperatura interior y tm = temperatura media exterior, de tm = temperatura exterior máxima  (margen diario)/2
Note 3. Ajustes a meses distintos de julio: Para propósitos de diseño, los datos suficientes para más o menos 2 semanas desde
el 21 día del mes determinado.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.15 (I-P) Diferencias de Temperatura de Carga de Refrigeración (CLTDs)
Aproximadas para Paredes Iluminadas por Luz Solar
—Latitud 48°N, Julio
PRECAUCION: Datos aproximados Utilizar sólo para cálculos preliminares.
12.fm Page 277 Thursday, March 3, 2016 2:00 PM
7
4
13
16
8
0
0
1
0
8
6
23
28
18
2
2
2
2
9
6
26
34
26
6
4
4
4
6
0
0
1
1
1
1
1
1
7
0
0
1
0
0
0
1
0
8
1
2
3
1
–1
0
0
0
9
2
7
8
4
0
0
1
0
6
–1
–1
–1
–1
–1
–1
–1
–1
7
–1
1
1
0
–1
–1
–1
–1
8
2
7
8
4
–1
0
0
–1
9
4
14
18
11
1
1
1
1
6
2
2
2
2
2
3
4
3
7
1
2
2
2
2
3
3
2
8
2
4
4
3
1
2
2
2
9
3
8
9
6
2
2
2
2
6
5
6
7
7
6
9
10
8
7
4
5
6
6
6
8
9
7
8
4
5
6
6
5
7
8
6
9
4
6
7
6
4
6
7
6
6
6
7
8
8
8
11
12
10
7
6
6
7
7
7
10
11
9
8
5
6
6
6
6
8
9
8
9
4
6
6
6
5
7
8
7
Tiempo Solar, h
Masa Baja, Pared Valor-R Bajo (No. 1)
10 11 12 13 14 15 16 17 18
7
9 12 14 15 16 16 16 16
24 19 16 15 16 16 16 15 13
36 33 27 20 17 17 17 16 14
31 32 31 27 22 18 17 16 14
12 18 24 28 29 28 24 19 15
7
9 14 22 29 36 39 38 34
7
9 12 15 23 33 41 44 44
7
9 12 14 16 21 28 34 36
Masa Baja, Pared Valor-R Medio (No. 4)
10 11 12 13 14 15 16 17 18
3
4
6
7
9 11 12 13 14
12 16 18 18 18 17 17 17 16
15 21 25 27 26 24 22 21 19
9 15 20 24 26 26 24 23 21
1
3
7 11 16 19 23 24 23
1
3
4
7 10 15 20 26 29
1
3
4
6
8 12 17 22 28
1
2
4
6
8 11 13 17 21
Masa Baja, Pared Valor-R Alto (No. 2)
10 11 12 13 14 15 16 17 18
5
6
8 10 12 13 14 15 16
20 22 21 18 17 16 16 16 16
26 31 32 29 24 21 19 18 17
18 24 28 29 28 25 22 19 17
4
8 13 18 23 26 27 26 22
3
5
7 11 17 23 29 34 36
3
5
7
9 13 18 26 33 38
3
5
7
9 12 14 18 23 28
Masa Alta, Pared Valor-R Baja (No. 5)
10 11 12 13 14 15 16 17 18
3
4
5
7
8
9 11 12 13
11 14 15 16 16 16 16 16 16
14 18 22 22 22 21 21 19 19
10 14 18 21 22 22 21 21 19
2
4
7 11 14 17 19 20 20
3
3
5
7
9 14 18 22 26
3
4
5
6
8 11 16 21 25
2
3
4
6
8
9 12 15 19
Masa Alta, Pared Valor-R Media (No. 11)
10 11 12 13 14 15 16 17 18
4
4
5
6
6
7
8
8
9
8
9 11 12 12 13 13 13 13
9 12 14 16 17 17 17 17 17
8
9 12 13 15 16 17 17 17
4
4
6
7
9 11 13 14 15
6
6
6
7
8
9 12 14 17
7
6
7
7
7
8 11 13 16
5
5
6
6
7
7
8 10 12
Masa Alta, Pared Valor-R Alta (No. 16)
10 11 12 13 14 15 16 17 18
4
4
4
4
5
6
6
7
8
6
7
8
9 11 12 12 13 13
7
8 11 12 14 16 17 17 17
6
7
8 10 12 14 15 16 17
4
4
4
5
6
8
9 11 13
7
6
6
6
6
7
8 10 12
7
7
6
6
6
7
8
9 11
6
6
5
5
6
6
7
8
9
19
15
11
11
11
11
25
34
31
20
9
8
8
8
8
13
18
16
21
6
6
6
6
6
7
9
8
22
4
4
4
4
4
4
5
5
19
15
16
18
19
22
32
33
25
20
15
14
16
17
19
32
36
27
21
14
13
14
14
17
28
33
27
22
12
11
12
12
13
23
28
23
19
16
14
15
16
18
34
41
32
20
15
13
13
13
15
29
37
30
21
12
10
11
11
12
22
28
23
22
9
8
8
8
8
15
19
16
19
13
15
18
18
19
27
29
22
20
13
14
16
17
18
27
30
23
21
13
13
14
15
16
24
28
22
22
12
12
13
13
13
21
24
19
19
10
14
17
17
16
18
18
14
20
11
14
17
17
16
20
21
16
21
11
13
16
16
15
20
22
17
22
11
13
15
15
14
19
21
17
19
9
13
18
17
14
15
14
11
20
9
14
18
17
15
17
17
13
21
10
14
17
17
15
18
19
15
22
11
13
17
17
15
19
21
16
PRECAUCION: Datos aproximados. Utilizar sólo para cálculos preliminares.
277
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
6
–1
1
1
0
–1
–1
–1
–1
Datos de Carga de Aire
Cara a la
Pared
N
NE
E
SE
S
SO
O
NO
Cara a la
Pared
N
NE
E
SE
S
SO
O
NO
Cara a la
Pared
N
NE
E
SE
S
SO
O
NO
Cara a la
Pared
N
NE
E
SE
S
SO
O
NO
Cara a la
Pared
N
NE
E
SE
S
SO
O
NO
Cara a la
Pared
N
NE
E
SE
S
SO
O
NO
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.13 (SI) Diferencias de Temperatura de Carga de Refrigeración para
Paredes Iluminadas por Luz Solar—Latitud 40°N, Julio
12.fm Page 278 Thursday, March 3, 2016 2:00 PM
Tiempo Solar, h
5
6
7
8
9
N
NE
E
SE
S
SO
O
NO
Caliente
0
0
0
0
0
0
0
0
0
19
54
57
26
5
5
5
5
10
35
124
139
74
15
15
15
15
55
36
150
177
104
23
23
23
23
113
36
144
180
114
30
30
30
30
170
N
NE
E
SE
S
SO
O
NO
Caliente
0
0
0
0
0
0
0
0
0
25
79
86
42
8
8
8
8
20
29
129
153
90
17
17
17
17
66
28
139
184
125
24
24
24
24
120
32
120
182
142
36
30
30
30
171
N
NE
E
SE
S
SO
O
NO
Caliente
14
32
31
11
3
3
3
3
5
28
101
112
58
11
11
11
11
32
24
130
165
106
18
18
18
18
73
27
126
188
143
30
24
24
24
120
31
95
182
164
58
30
30
30
163
10 11 12 13 14 15 16 17 18 19 20 21 22
Datos de Carga de Aire
Latitud 24°N, Julio
38 40 42 42 40 38
115 78 58 49 44 38
154 107 68 54 46 40
106 83 59 50 44 38
35 40 43 43 40 37
35 39 42 61 88 110
35 39 41 67 116 160
35 39 41 51 83 122
218 253 271 273 258 225
Latitud 36°N, Julio
36 39 40 41 39 36
84 58 50 45 41 37
155 107 67 54 45 39
140 119 86 58 48 40
53 70 80 79 68 52
35 38 57 90 122 141
35 38 40 66 115 159
35 38 40 40 56 93
215 246 263 265 251 221
Latitud 48°N, Julio
34 37 38 38 37 35
61 49 44 41 38 35
153 104 65 51 43 38
168 152 119 77 54 43
90 116 130 130 116 88
34 46 82 122 152 168
34 36 38 64 112 156
34 36 38 38 40 67
200 226 241 242 230 205
39
32
33
32
32
118
186
151
176
43
25
25
25
24
105
184
158
115
32
14
14
14
14
62
118
106
54
11
6
6
6
6
24
44
39
24
6 3
3 1
3 1
3 1
3 1
12 6
21 11
19 9
12 6
1
1
1
1
1
3
5
5
3
32
32
33
34
38
144
188
129
178
33
26
26
27
29
127
191
148
124
36
17
17
17
18
85
149
127
66
12
7
7
7
7
32
53
43
28
6 3
3 2
3 2
3 2
3 2
15 8
25 12
21 10
13 7
1
1
1
1
1
4
6
5
3
31
31
32
35
56
166
186
106
170
27
26
27
28
37
146
193
134
125
34
19
19
20
24
106
167
134
76
25
10
10
10
12
50
89
76
35
9 4
4 2
4 2
4 2
5 3
22 11
36 17
30 14
16 8
2
1
1
1
1
5
9
7
4
Las tablas no consideran el tipo de zona y son conservadoras. Los datos aplican directo a: (1) vidrio estándar de doble
fuerza sin sombra en el interior y (2) cielo claro, día 21 del mes.
Ajustes a los datos de la tabla:
• Latitudes distintas a 24, 36 y 48°N.
Interpolación lineal es aceptable.
• Meses distintos a julio.
Para propósitos de diseño, los datos serán suficientes para más o menos 2 semanas del 21 día del mes determinado.
• Otro tipo de vidrio y sombra interna.
Utilice los coeficientes de sombreado como multiplicador.
• Vidrio sombreado externamente.
Utilice la orientación norte.
278
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Cara al
Vidrio
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.16 (I-P) Carga de Refrigeración Solar
para Vidrios Iluminados por Luz Solar (SCL)
Las Tablas no consideran el tipo de zona y son conservadoras.
Utilizar sólo para cálculos preliminares.
12.fm Page 279 Thursday, March 3, 2016 2:00 PM
Carga de Refrigeración Solar (W/m2) para Vidrios Iluminados por
Luz Solar – Latitud 40°N, Julio
Utilizar sólo para cálculos preliminares.
Tiempo Solar, h
Cara al
Vidrio
5
6
N
3
79 85 88 101 110 120 126 126 123 113 98 98 113 38 19
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23
9
3
3
NE
6 268 406 422 353 236 173 151 139 126 117 101 82 57 22
9
6
3
0
E
6 293 495 583 576 485 334 211 167 142 123 104 82 57 22
9
6
3
0
SE
3 148 299 413 473 473 413 306 198 154 129 107 85 57 22
9
6
3
0
6
0
28 54 79 129 202 268 306 302 265 198 132 98 63 25 13
3
0
SO
0
28 54 76 95 110 123 202 318 419 476 479 419 293 110 54 25 13
6
O
0
28 54 76 95 110 120 126 205 359 498 589 605 491 180 85 41 19
9
NO
0
28 54 76 95 110 120 126 126 158 265 381 450 410 145 69 35 16
9
76 217 378 532 665 759 810 816 772 684 554 394 221 91 44 22
6
Caliente 0
9
Aplicar los datos directamente a vidrio estándar de doble fuerza y cielo claro en el 21 día del mes.
Ajustes a los datos de la tabla:
• Para propósitos de diseño, los datos serán suficientes para más o menos 2 semanas desde el 21 día de julio.
• Para otros tipos de vidrio y sombra interna, multiplique los valores por coeficientes de sombreado apropiados.
• Para vidrios sombreados externamente, utilice valores de orientación norte.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
279
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos de Carga de Aire
S
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.16 (SI)
12.fm Page 280 Thursday, March 3, 2016 2:00 PM
Tipo de Vidrio
Datos de Carga de Aire
Claro
Claro
Patrón claro
Patrón absorbente de
calor
Coloreado
Absorbente de calorf
Patrón absorbente de
calor
Coloreado
Absorbente de calor
o patrón
Absorbente de calorf
Absorbente de calor
o patrón
3/32c
1/4 a 1/2
1/8 a 1/2
1/8
—
3/16, 7/32
3/16, 1/4
0.74, 0.71
0.46
3/16, 1/4
—
1/8, 7/32
0.59, 0.45
—
0.44 a 0.30
3/8
0.34
0.57
0.53
0.45
0.30
0.36
0.54
0.52
0.40
0.28
0.32
0.36
0.28
0.31
0.29 a 0.15
—
Vidrio revestido
reflectante
Tipo de Sombreado
Cortina Enrollable
Cortinas
Venecianas
Opacas
Translúcidas
Medio Luz Oscuro Blanco
Luz
d
d
0.87 a 0.80 0.74
0.67
0.81
0.39
0.44
(0.63)e (0.58)e
0.80 a 0.71
0.87 a 0.79
Espesor
Transmisión
Nominal,a
Solarb
pulg.
0.42
0.40
S.C. = 0.30g
0.24
0.25
0.23
= 0.40
= 0.50
= 0.60
0.33
0.42
0.50
0.29
0.38
0.44
a Referirse a la literatura del fabricante para valores.
b Para cortinas verticales con persianas opacas blanca y beige en la posición cerrada herméticamente, SC es 0.25 y 0.29
cuando es utilizada con vidrio de 0.71 a 0.80 de transmitancia.
c Espesor de vidrio residencial típico.
d De Van Dyck y Konen (1982), por 45° abra las cortinas venecianas, 35° incidencia solar, y 35° ángulo de perfil.
e Valores para cortinas venecianas cerradas. Utilice estos valores sólo cuando la operación está automatizada para la reduc-
* Nota: el coeficiente de sombreado (SC) ha sido sustituído por el coeficiente de ganancia de calor solar (SHGC) incluido
el efecto del ángulo de incidencia de radiación solar en el vidrio, y el efecto del tipo de encuadre. Esta tabla de coeficiente de sombreado es suficientemente exacta para los cálculos aproximados de carga de refrigeración de esta publicación. Para la parte de vidrio de un solo panel claro y fenestración coloreada, SC = SHGC/0.87. Esto no incluye efectos
de cuadro.
280
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
ción de la ganancia solar ( en contraposición al uso de la luz del día).
f Se refiere a vidrios absorbentes de calor coloreados de gris, bronce y verde.
g SC para vidrio sin dispositivo de sombreado.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.17 (I-P) Coeficientes de Sombreado para el Vidrio Solo con Sombreado
Interior por Cortinas Venecianas o Cortinas Enrollables
12.fm Page 281 Thursday, March 3, 2016 2:00 PM
Tipo de Vidrio
Coloreado
Absorbente de calorc
Luz
0.64
0.55
0.57
0.53
0.54
0.25
0.33
0.42
0.50
0.52
0.23
0.29
0.38
0.44
1.00
0.94
0.90
0.87
0.83
0.83
0.69
0.69
0.69
0.60
0.30
0.40
0.50
0.60
1.00
0.95
0.92
0.88
0.85
0.85
0.73
0.73
0.73
0.64
2.4 a 3.2
6
0.88
0.81
0.88
0.82
0.57
0.51
6
0.55
0.58
0.39
0.36
0.19
0.27
0.34
0.18
0.26
0.33
0.20
0.30
0.40
6
3
0.71
0.80
a Referirse a la literatura del fabricante para los valores.
b Para cortinas verticales con persianas opacas blancas y beige en la posición de cerrado herméticamente.
SC es 0.25 y 0.29 cuando son utilizados con vidrio de 0.71 a 0.80 de transmitancia.
c Se refiere a vidrios absorbentes de calor coloreados de gris, bronce y verde.
d Se refiere a unidades fabricadas en fábrica con 5, 6 ó 13 mm de espacio de aire o ventanas principales más ventanas de
tormentas.
* Nota: el coeficiente de sombreado (SC) ha sido sustituído por el coeficiente de ganancia de calor solar (SHGC) incluido
el efecto del ángulo de incidencia de radiación solar en el vidrio, y el efecto del tipo de encuadre. Esta tabla de coeficiente de sombreado es suficientemente exacta para los cálculos aproximados de carga de refrigeración de esta publicación, Para la parte de vidrio de un solo panel claro y fenestración coloreada, SC = SHGC/0.87. Esto no incluye efectos
de cuadro.
281
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Triple
Claro
Claro
Medio
2.4 a 6
6 a 13
9.5
13
3a 7
3
5.8 a 6.4
5.8 a 6.4
3 a 5.6
9.5
Vidrio revestido reflectante
Vidrio Aislado
Dobled
Claro afuera, claro adentra
Claro afuera, claro adentro
Absorción de calor hacia
afuera, claro adentro
Vidrio revestido reflectante
Cortinas Venecianasb
Datos de Carga de Aire
Sólo vidrio
Sólo
Claro
Claro
Claro
Claro
Patrón Claro
Patrón absorbente de calor
Absorbente de calor c
Patrón absorbente de calor
Sin Sombreado Interior
Espesor
Nominal
Cada
ho = 22.7
ho = 17.0
Panela, mm
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.17 (SI) Coeficientes de Sombreado* para Vidrio sin o con Sombreado
Interior de Cortinas Venecianas
Datos de Carga de Aire
Teatro, Matinée
Teatro, noche
Oficinas, hoteles, apartamentos
Oficinas, hoteles, apartamentos
Gran almacén, tienda al por menor
Droguería, banco
Restaurantec
Fábrica
Salón de baile
Fábrica
Bolera
Fábrica
Fábrica
Gimnasio
Ubicación
Varón
Adulto
390
390
450
475
550
550
490
800
900
1000
1500
1500
1600
2000
Ajustado,
M/Fa
330
350
400
450
450
500
550
750
850
1000
1450
1450
1600
1800
Calor Total, Btu/h
225
245
245
250
250
250
275
275
305
375
580
580
635
710
Calor
Sensible,
Btu/h
105
105
155
200
200
250
275
475
545
625
870
870
965
1090
Calor
Latente,
Btu/h
27
38
35
19
58
49
54
Alto V
60
Bajo V
% de Calor Sensible que
es Radianteb
Notas:
1. Valores tabulados están basados en 75°F temperatura de bulbo seco de sala. Para 80°F bulbo seco de sala,, el calor total permanece el mismo, pero los valores de calor sensible serán disminuidos en
aproximadamente 20% y los valores de calor latente aumentados por consiguiente.
2. También ver Tabla 4, Capítulo 9, para tipos adicionales de generación de calor metabólico.
3. Todos los valores serán redondeados cerca de 5 Btu/h
a La ganancia de calor ajustado está basado en porcentaje normal de hombres, mujeres y niños, para la aplicación indicada, y asume que la ganancia de una hembra adulta es 85% d aquella para un varón
adulto y la ganancia de un niño es 75% de aquella para un adulto varón, .
b Los valores aproximados de los datos en la Tabla 6, Capítulo 9, donde V es la velocidad del aire con límites mostrados en esa tabla. .
c La ganancia ajustada de calor incluye 60 Btu/h para comida por individuo (30 Btu/h sensible y 30 Btu/h latente).
d Calcule una persona por bolera actualmente boleando y todos los otros sentados (400 Btu/h) o de pie o caminando lentamente (550 Btu/h).
Sentado en el teatro
Sentado en el teatro, noche
Sentado, trabajo muy liviano
Trabajo de oficina moderadamente activo
De píe, trabajo ligero, caminar
Caminar, de pie
Trabajo sedentario
Trabajo de banco ligero
Baile moderado
Caminar 3 mph, trabajo en máquina liviana
Bolosd
Trabajo pesado
Trabajo en maquinaria pesada, elevador
Atletismo
Grado de Actividad
Tabla 12.18 (I-P) Tipos Representativos en la que el Calor y la Humedad son Emitidos por
los Seres Humanos en Diferentes Estados de Actividad [2013F, Ch 18, Tbl 1]
12.fm Page 282 Thursday, March 3, 2016 2:00 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
282
Teatro, Matinée
Noche, Teatro
Oficinas, hoteles, apartamentos
Oficinas, hoteles, apartamentos
Grandes Almacenes, tiendas al por menor
Droguería, banco
Restaurantec
Fábrica
Salón de baile
Fábrica
Bolera
Fábrica
Fábrica
Gimnasio
Sentado en el teatro
Sentado en el teatro, noche
Sentado, trabajo muy ligero
Trabajo de oficina moderadamente activo
De pie, trabajo ligero, caminar
Caminar, de pie
Trabajo sedentario
Trabajo de banco ligero
Baile moderado
Caminar 4.8 km/h trabajo en máquina liviana
Bolosd
Trabajo pesado
Trabajo en máquina pesada; elevador
Atletismo
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Varón
Adulto
115
115
130
140
160
160
145
235
265
295
440
440
470
585
Calor
Calor
Ajustado, Sensible, W Latente, W
a
M/F
95
65
30
105
70
35
115
70
45
130
75
55
130
75
55
145
75
70
160
80
80
220
80
140
250
90
160
295
110
185
425
170
255
425
170
255
470
185
285
525
210
315
Calor Total, W
27
38
35
19
58
49
54
Alto V
60
Bajo V
% Calor Sensible que es
Radianteb
Notas:
1. Valores tabulados están basados en 24°C temperatura de bulbo seco de sala. Para 27°C bulbo seco de sala, el calor total permanece el mismo, pero los valores de calor sensible serán disminuidos en aproximadamente 20% y los valores de calor latente aumentados por consiguiente.
2. También ver Tabla 4, Capítulo 9, para tipos adicionales de generación de calor metabólico.
3. Todos los valores serán redondeados cerca de 5 W.
a La ganancia de calor ajustado está basado en porcentaje normal de hombres, mujeres y niños, para la aplicación indicada, y asume que la ganancia de una hembra adulta es 85% de aquella para un varón
adulto y la ganancia de un niño es 75% de aquella para un adulto varón, .
b Los valores aproximados de los datos en la Tabla 6, Capítulo 9, donde V es la velocidad del aire con límites mostrados en esa tabla. .
c La ganancia ajustada de calor incluye 18 W para comida por individuo (9 W sensible y 9 W latente).
d Calcule una persona por bolera actualmente boleando y todos los otros sentados (117 W) o de pie o caminando lentamente (231 W).
Ubicación
Grado de Actividad
Tabla 12.18 (SI) Tipos Representativos en la que el Calor y la Humedad son Emitidos por
los Seres Humanos en Diferentes Estados de Actividad [2013F, Ch 18, Tbl 1]
12.fm Page 283 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
283
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
12.fm Page 284 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
La energía absorbida por la estructura y contenidos contribuye al espacio de la carga de
refrigeración solo después de un lapso de tiempo, algunos todavía siguen re-irradiando después
que las fuentes de calor han sido apagadas. Esto puede hacer que la carga disminuya que la ganancia de calor instantáneo.
La tasa instantánea de la ganancia de calor de las luces , qel Btu/h (kW):
donde
W
Ful
Fsa
3.41
=
=
=
=
qel = 3.41 WFulFsa
(I-P)
qel = qel = WFulFsa
(SI)
total vatiaje de luces instalado
factor de uso de iluminación (proporción en uso)
factor de tolerancia especial de iluminación
factor de conversión
284
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
El total de vatiaje de luz es obtenido de los tipos de todas las lámparas instaladas, ambos
para iluminación general y para uso de exhibición. Los balastos no están incluidos, pero están
dirigidos por un factor separado. Los vatiajes de balastos magnéticos son significativos; el consumo de energía de balastos electrónicos de alta eficiencia pueden ser significativos comparados a
aquellos de las lámparas.
El factor de uso de iluminación es la relación del vatiaje en uso, por las condiciones bajo las
cuales el estimado de la carga se está haciendo, al vatiaje total instalado. Para aplicaciones comerciales como tiendas, el uso del factor es generalmente de 1.0.
El factor de tolerancia especial es la relación del consumo de potencia de los artefactos de
alumbrado, incluyendo lámparas y balastos, al consumo de potencia nominal de las lámparas.
Para luces incandescentes, este factor es 1. Para luces fluorescentes, representa la potencia consumida por el balasto así como el efecto del balasto en el consumo de potencia de la lámpara. El
factor de tolerancia especial puede ser menor de 1 para balastos electrónicos que reducen el consumo de electricidad por debajo del consumo de potencia de la lámpara. Utilice los valores del
fabricante para alimentación del sistema (lámparas + balastos), cuando estén disponibles.
Para lámparas de descarga de alta intensidad (ej. aluro de metal, vapor de mercurio, lámparas
de vapor de sodio de alta y baja presión), el consumo de potencia del sistema de iluminación
actual estará disponible del fabricante del artefacto o balasto. Los balastos disponibles para haluro
de metal y lámparas de vapor de sodio de alta presión pueden tener factores de tolerancia especial
desde alrededor de 1.3 (para lámparas de vatiaje bajo) hasta 1.1 (para lámparas de vatiaje alto).
Un procedimiento alternativo es estimar la ganancia de calor de iluminación en una base por
pie cuadrado. Tal método puede ser requerido cuando los planes finales de iluminación no están
disponibles. Tabla 12.19 (Tabla 12.15) muestran la densidad de potencia de iluminación máxima
(LPD) (ganancia de calor de iluminación por pie cuadrado (metro) permitido por la Norma de
ASHRAE 90.1-2010 para una gama de tipos de espacios.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Ganancia de Calor de Iluminación
12.fm Page 285 Thursday, March 3, 2016 2:00 PM
Densidades de Potencia de Iluminación Utilizando el Método
Espacio por Espacio [Std 90.1-2010, Tbl 9.6.1]
Datos de Carga de Aire
285
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
LPD,
LPD,
Tipos de Espacio Específico – Edificio
W/ft2
W/ft2
Oficina – adjunta
1.1 Gimnasio/centro de ejercicios
Oficina – plan abierto
1.1
Área de Juego
1.4
Conferencia/reunión/uso múltiple
1.3
Área de Ejercicios
0.9
Sala de clase/conferencia/entrenamiento
Palacio de Justicia/estación de policía/
1.4
penitenciaría
Para penitenciaria
1.3
Sala de la Corte
1.9
Vestíbulo
1.3
Celdas de confinamiento
0.9
Para hotel
1.1
Cámaras de los jueces
1.3
Para teatro de artes escénicas
3.3 Estaciones de bomberos
Teatro para películas
1.1
Cuarto de máquina
0.8
Audiencia/área de sentados
0.9
Dormitorios
0.3
Para gimnasio
0.4 Oficina de Correo – área de selección
1.2
Para centro de ejercicios
Centro de Convenciones – espacio de
0.3
1.3
exhibición
Para centro de convenciones
0.7 Biblioteca
Para penitenciaría
0.7
Archivo de tarjetas y catalogación
1.1
Para edificios religiosos
1.7
Estantes
1.7
Para campo de deportes
0.4
Área de lectura
1.2
Para teatro de artes escénicas
2.6 Hospital
Para teatro de películas
1.2
Emergencia
2.7
Para transporte
0.5
Recuperación
0.8
Atrio – primeros tres pisos
0.6
Estación de enfermeras
1.0
Atrio – cada piso adicional
0.2
Examen/tratamiento
1.5
Salón/recreación
1.2
Farmacia
1.2
Para hospital
0.8
Cuarto de paciente
0.7
Comedor
0.9
Sala de operaciones
2.2
Para penitenciaría
1.3
Enfermería
0.6
Para hotel
1.3
Suministro médico
1.4
Para motel
1.2
Terapia física
0.9
Para salón bar/comedor
1.4
Radiología
0.4
Para comedor familiar
2.1
Lavadero –lavadora
0.6
Preparación de alimentos
1.2 Automotor – servicio de reparación
0.7
Laboratorio
1.4 Fabricación
Baños
Panel bajo (<piso de 25 pies a altura
0.9
1.2
de techo)
Vestidor/armario/cuarto de prueba
Panel alto (piso de 25 pies a altura
0.6
1.7
de techo)
Corredor/transición
0.5
Fabricación detallada
2.1
Para hospital
1.0 Sala de equipos
1.2
Para instalación de fabricación
0.5
Sala de control
0.5
Escaleras-activa
0.6 Hotel/mote/cuarto de huéspedes
1.1
Almacenamiento activo
0.8 Dormitorio – viviendas
1.1
Tipos de Espacio Común*
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.19 (I-P)
12.fm Page 286 Thursday, March 3, 2016 2:00 PM
Tipos de Espacio Común*
Datos de Carga de Aire
Para hospital
Almacenamiento inactivo
Para museo
Eléctrico/mecánico
Taller
Área de Ventas [para iluminación de
acento, ver la Sección 9.6.2(B) de la
Norma de ASHRAE 90.1]
LPD,
LPD,
Tipos de Espacio Específico – Edificio
W/ft2
W/ft2
0.9 Museo
0.3
Exhibición general
1.0
0.8
Restauración
1.7
Banco/oficina – área de actividad
1.5
1.5
bancaria
1.9 Edificios religiosos
1.7
2.4
0.9
1.7
1.7
2.7
2.3
1.4
1.4
0.9
0.2
0.6
1.0
1.5
*En los casos donde ambos un tipo de espacio común y un tipo específico de edificio están indicados, el tipo de espacio específico del edificio aplica.
286
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Púlpito de adoración, coro
Sala de fraternidad
Venta al por menor
Área de ventas [para iluminación de
acento, ver sección 9.6.3(C) de
Norma 90.1 de ASHRAE]
Corredor de centro comercial
Campo de deporte
Área de círculo de deportes
Área de deportes de cancha
Área de campo de juego interior
Bodega
Almacenaje de material fino
Medio/almacenaje de material
voluminoso
Garaje de estacionamiento – área de
garaje
Transportación
Aeropuerto—corredor
Aire/tren/bus—área de equipaje
Terminal—mostrador de boleto
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.19 (I-P) Densidades de Potencia de Iluminación Utilizando el Método
Espacio por Espacio [Std 90.1-2010, Tbl 9.6.1] (Continuo)
12.fm Page 287 Thursday, March 3, 2016 2:00 PM
Tipos de Espacio Común*
Oficina – adjunta
Oficina – plan abierto
Conferencia/reunión/uso múltiple
Sala de clases/conferencia/
entrenamiento
LPD,
LPD,
Tipos de Espacio Específico – Edificio
W/m2
W/m2
12 Gimnasio/centro de ejercicio
12 Área de juego
15
14
Área de ejercicio
10
15
Para centro de convención
Para penitenciaría
Para edificios religiosos
Para campos de deportes
Para teatro de artes escénicas
Para teatro de películas
Para transporte
Atrio – primeros tres pisos
Atrio – cada piso adicional
Salón/recreación
Para hospital
Área de comedor
Para penitenciaría
Para hotel
Para motel
Para salón bar/comedor
Para comedor familiar
Preparación de alimentos
Laboratorio
Baños
8
8
18
4
28
13
5
6
2
13
9
10
14
14
13
15
23
13
15
Vestidor/armario/cuarto de prueba
Corredor/transición
Para hospital
Para instalación de fabricación
Escaleras – activas
Almacenaje activo
3
10
6
5
11
5
6
9
20
10
14
9
3
13
14
12
18
13
29
9
11
16
13
8
24
6
15
10
4
6
8
13
18
23
13
5
12
12
287
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
14
14
12
36
12
10
4
Datos de Carga de Aire
Para penitenciaría
Vestíbulo
Para hotel
Para teatro de artes escénicas
Para teatro de películas
Audiencia/área de sentados
Para gimnasio
Para centro de ejercicios
Palacio de Justicia/estación de policía/
penitenciaría
Sala de la Corte
Celdas de confinamiento
Cámaras de los Jueces
Estaciones de Bomberos
Cuarto de máquina
Dormitorios
Oficina de correo—área de selección
Centro de convención—especio de
exhibición
Biblioteca
Archivo de tarjetas y catalogación
Estantes
Área de lectura
Hospital
Emergencia
Recuperación
Estación de enfermeras
Examen/tratamiento
Farmacia
Cuarto de paciente
Sala de operación
Enfermería
Suministro médico
Terapia física
Radiología
Lavandería – lavadora
Automotor – servicio/reparación
Fabricación
Panel bajo (<piso de7.6 m a altura de
techo)
Panel alto (piso de 7.6 m a altura de
techo)
Fabricación detallada
Sala de equipos
Sala de control
Hotel/motel/cuartos de huéspedes
Dormitorio – viviendas
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.19 (SI) Tabla 12.15 Densidades de Potencia de Iluminación Utilizando el
Método Espacio por Espacio [Std 90.1-2010, Tbl 9.6.1]
12.fm Page 288 Thursday, March 3, 2016 2:00 PM
Tipos de Espacio Común*
Datos de Carga de Aire
Para hospital
Almacenaje inactivo
Para museo
Eléctrico/mecánico
Taller
Área de ventas [para iluminación de
acento, ver Sección 9.6.2 (B) de
Norma de ASHRAE 90.1]
LPD,
LPD,
Tipos de Espacio Específico – Edificio
W/m2
W/m2
10 Museo
3
Exhibición general
11
9
Restauración
18
Banco/oficina – área de actividad
16
16
bancaria
20 Edificios religiosos
18
26
10
18
18
29
25
15
15
10
2
6
11
16
*En los casos donde ambos un tipo de espacio común y un tipo específico de edificio están indicados, el tipo de espacio específico del edificio aplica.
288
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Púlpito de adoración, coro
Sala de fraternidad
Venta al por menor
Área de ventas [para iluminación de
acento, ver Sección 9.6.3(C) de
Norma de ASHRAE 90.1]
Corredor de centro comercial
Campo de deporte
Área de círculo de deportes
Área de deportes de cancha
Área de campo de juego interior
Bodega
Almacenaje de material fino
Medio/almacenaje de material grueso
Garaje de estacionamiento – área de
garaje
Transporte
Aeropuerto – corredor
Aire/tren/bus – área de equipaje
Terminal—mostrador para boletos
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.19 (SI) Tabla 12.15 Densidades de Potencia de Iluminación Utilizando el
Método Espacio por Espacio [Std 90.1-2010, Tbl 9.6.1] (Continuo)
12.fm Page 289 Thursday, March 3, 2016 2:00 PM
Tabla 12.20 Parámetros de Ganancia de Calor de Iluminación para Condiciones
de Operación Típica [2013F, Ch 18, Tbl 3]
Categoría de
Luminaria
Espacio
Fracción
de
Radiativa
Fracción
Notas
0.64 a
0.74
0.48 a
0.68
Luminaria
fluorescente
empotrada
con lente
0.40 a
0.50
0.61 a
0.73
Luminaria
fluorescente
compacta
0.12 a
0.24
Utilice valores medios en la mayoría de las situaciones
Puede fracción de espacio alta, y bajar la fracción radiatia para luminarias con retorno del lado de ranura
• Puede utilizar valores bajos de ambas fracciones para
luminaria directa/indirecta
• Puede utilizar valores altos de ambas fracciones para
retornos de conductos
Puede ajustar valores en la misma manera como para
las luminarias fluorescentes empotradas sin lentes
•
Utilice valores medios o altos si las características
detalladas no se conocen
Utilice valor bajo para fracción de espacio y valor alto
para fracción radiativa si hay grandes huecos en el
reflector de la luminaria
Utilice valores medios si el tipo de lámpara no es conocido
Utilice valor bajo para fracción de espacio si lámpara
estándar (ej.Lamp-A) es utilizada
Utilice valor alto para fracción de espacio si la lámpara
reflectora (ej. Lamp-BR) es utilizada
Utilice valor bajo para fracción radiativa para luminaria
de montaje de superficie
Utilice valor alto para fracción radiativa para luminaria
colgante
0.95 a 1.0 •
•
Luminaria
incandescente
0.70 a
0.80
0.95 a 1.0
•
•
No en techo
luminaria
fluorescente
•
1.0
0.5 a 0.57
•
Fuente: Fisher y Chantrasrisalai (2006).
289
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
•
Datos de Carga de Aire
•
•
Luminaria
fluorescente
empotrada sin
lente
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
La Tabla 12.20 proporciona una serie de datos de diseño bajo condiciones de operación típicas: flujo de aire 1 cfm/pie2 (6 L/s m2), suministran aire entre 59°F y 62°F (15°C y 18°C),temperatura de cuarto entre 72°F y 75°F (22°C y 24°C) y la entrada de calor de iluminación en un
intervalo de 0.9 a 2.6 W/pie2 (10 a 28 W/m2). Para una luminaria fluorescente sin lentes, la
Figura 12.1 suministra datos más precisos. Los datos pueden utilizarse con juicio.
Figura 12.1 (I-P) Parámetros de Ganancia de Calor para Luminaria Fluorescente Empotrada sin
Lentes [2013F, Ch 18, Fig 3]
290
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 12.1 (SI) Parámetros de Ganancia de Calor para Luminaria Fluorescente Empotrada sin
Lentes [2013F, Ch 18, Fig 3]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Datos de Carga de Aire
12.fm Page 290 Thursday, March 3, 2016 2:00 PM
12.fm Page 291 Thursday, March 3, 2016 2:00 PM
La tasa instantánea de ganancia de calor del equipo operado por motores eléctricos dentro de
un espacio condicionado .
=
=
=
=
=
(I-P)
qem = (P/EM) FUM FLM
(SI)
calor equivalente de la operación del equipo, Btu/h (kW)
potencia nominal del motor, hp (kW)
rendimiento del motor, fracción decimal < 1.0
factor de utilización del motor 1.0 ó <1.0 (proporción operacional)
factor de carga del motor 1.0 ó <1.0
Cuando el motor está fuera del espacio condicionado, pero la carga está dentro,
qem = 2545 P FUM FLM
(I-P)
qem = P FUM FLM
(SI)
Cuando el motor está dentro del espacio condicionado, pero la carga está fuera,
 1.0 – E M 
- F UM F LM
q em = 2545 P  -------------------- EM 
La salida de calor de un motor es generalmente proporcional a la carga del motor, dentro de
los límites de sobrecarga nominal. Debido a la corriente del motor sin carga típicamente alta, pérdidas fijas y otras razones, FLM es generalmente asumida a ser la unidad, y ningún ajuste debe ser
hecha para baja carga o sobrecarga a no ser que la situación es fija y puede ser exactamente establecida y los datos de eficiencia de carga reducida pueden ser obtenidos del fabricante del motor.
A menos que la literatura técnica del fabricante lo indique de otra manera, la ganancia de
calor del motor debe sr igual dividida entre componentes radiantes y convectivos para los cálculos
de carga de refrigeración subsiguientes.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
291
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos de Carga de Aire
donde
qem
P
EM
FUM
FLM
qem = 2545 (P/EM) FUM FLM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Ganancia de Calor de Motores y Sus Cargas
12.fm Page 292 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire


Fuente: Norma 90.1-2010 de ASHRAE
* Eficiencias nominales establecidas en acuerdo con la Norma MG1 NEMA. Diseño A y Diseño B son designaciones
de clase de diseño de la Asociación Nacional de Fabricantes Eléctricos (NEMA) para frecuencia fija pequeña y
mediana AC de motores de inducción jaula de ardilla.
292
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Eficiencia de Carga Completa Nominal Mínima (%) para Motores Fabricados en o después
de Diciembre 19, 2010
Motores Enfriados por
Motores a Prueba de
Ventilador Totalmente
Goteo Abiertos
Cubiertos
2
4
6
2
4
6
Número de Postes
Velocidad Sincrónica (RPM)
3600
1800
1200
3600
1800
1200
Caballos de fuerza del Motor
1
77.0
85.5
82.5
77.0
85.5
82.5
1.5
84.0
86.5
86.5
84.0
86.5
87.5
2
85.5
86.5
87.5
85.5
86.5
88.5
3
85.5
89.5
88.5
86.5
89.5
89.5
5
86.5
89.5
89.5
88.5
89.5
89.5
7.5
88.5
91.0
90.2
89.5
91.7
91.0
10
89.5
91.7
91.7
90.2
91.7
91.0
15
90.2
93.0
91.7
91.0
92.4
91.7
20
91.0
93.0
92.4
91.0
93.0
91.7
25
91.7
93.6
93.0
91.7
93.6
93.0
30
91.7
94.1
93.6
91.7
93.6
93.0
40
92.4
94.1
94.1
92.4
94.1
94.1
50
93.0
94.5
94.1
93.0
94.5
94.1
60
93.6
95.0
94.5
93.6
95.0
94.5
75
93.6
95.0
94.5
93.6
95.4
94.5
100
93.6
95.4
95.0
94.1
95.4
95.0
125
94.1
95.4
95.0
95.0
95.4
95.0
150
94.1
95.8
95.4
95.0
95.8
95.8
200
95.0
95.8
95.4
95.4
96.2
95.8
250
95.0
95.8
95.4
95.8
96.2
95.8
300
95.4
95.8
95.4
95.8
96.2
95.8
350
95.4
95.8
95.4
95.8
96.2
95.8
400
95.8
95.8
95.8
95.8
96.2
95.8
450
95.8
96.2
96.2
95.8
96.2
95.8
500
95.8
96.2
96.2
95.8
96.2
95.8
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.21 (I-P) Eficiencia de Carga Completa Nominal Mínima para Motores
Eléctricos de Servicio General 60 HZ NEMA (Subtipo I) Frecuencia de 600 Voltios o
Menos (Bobinado Libre)* [2013F, Ch 18, Tbl 4]
12.fm Page 293 Thursday, March 3, 2016 2:00 PM


293
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos de Carga de Aire
Fuente: Norma 90.1-2010 de ASHRAE
* Eficiencias nominales establecidas en acuerdo con la Norma MG1 NEMA. Diseño A y Diseño B son designaciones de clase de diseño de la Asociación Nacional de Fabricantes Eléctricos (NEMA) para frecuencia fija
pequeña y mediana AC de motores de inducción jaula de ardilla.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Eficiencia de Carga Completa Nominal Mínina para Motores Fabricados en o después de
Diciembre 19, 2010
Motores Enfriados por
Motores a Prueba de Goteo
Ventilador Totalmente
Abiertos
Cubiertos
2
4
6
2
4
6
Número de Postes
Velocidad Sincrónica (RPM)
3600
1800
1200
3600
1800
1200
Kilovatios de motor
0.8
77.0
85.5
82.5
77.0
85.5
82.5
1.1
84.0
86.5
86.5
84.0
86.5
87.5
1.5
85.5
86.5
87.5
85.5
86.5
88.5
2.2
85.5
89.5
88.5
86.5
89.5
89.5
3.7
86.5
89.5
89.5
88.5
89.5
89.5
5.6
88.5
91.0
90.2
89.5
91.7
91.0
7.5
89.5
91.7
91.7
90.2
91.7
91.0
11.1
90.2
93.0
91.7
91.0
92.4
91.7
14.9
91.0
93.0
92.4
91.0
93.0
91.7
18.7
91.7
93.6
93.0
91.7
93.6
93.0
22.4
91.7
94.1
93.6
91.7
93.6
93.0
29.8
92.4
94.1
94.1
92.4
94.1
94.1
37.3
93.0
94.5
94.1
93.0
94.5
94.1
44.8
93.6
95.0
94.5
93.6
95.0
94.5
56.0
93.6
95.0
94.5
93.6
95.4
94.5
74.6
93.6
95.4
95.0
94.1
95.4
95.0
93.3
94.1
95.4
95.0
95.0
95.4
95.0
111.9
94.1
95.8
95.4
95.0
95.8
95.8
149.2
95.0
95.8
95.4
95.4
96.2
95.8
186.5
95.0
95.8
95.4
95.8
96.2
95.8
223.8
95.4
95.8
95.4
95.8
96.2
95.8
261.1
95.4
95.8
95.4
95.8
96.2
95.8
298.4
95.8
95.8
95.8
95.8
96.2
95.8
357.7
95.8
96.2
96.2
95.8
96.2
95.8
373.0
95.8
96.2
96.2
95.8
96.2
95.8
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.21 (SI) Eficiencia de Carga Completa Nominal Mínima para Motores
Eléctricos de Servicio General 60 HZ NEMA (Subtipo I) Frecuencia de 600 Voltios o
Menos (Bobinado Libre)* [2013F, Ch 18, Tbl 4]
Datos de Carga de Aire
Gabinete: servicio caliente (grande), aislado*
Servicio caliente (grande), sin aislamiento
Pruebas (grande)*
Pruebas (pequeño 15-estante)
Urna de preparación de café
Calentadores de cajón, 2-cajones (mantener humedad)*
Cocinar huevo
Máquina de café expreso*
Calentador de alimentos: mesa de vapor (tipo 2 pozos)
Congelador (pequeño)
Rodillo de perro caliente*
Placa caliente: un quemador, alta velocidad
Caja comida caliente (mantener seco)*
Caja comida caliente (mantener húmedo)*
Horno micro-onda: comercial (trabajo pesado)
Horno: encimera de hornear con transportador/acabado*
Panini*
Palomitas de maíz*
Reserva
1,200
3,500
1,400
3,900
1,200
500
700
1,200
3,500
1,100
2,400
3,000
2,500
3,300
0
12,600
3,200
200
Nominal
6,800
6,800
17,400
14,300
13,000
4,100
10,900
8,200
5,100
2,700
3,400
3,800
31,100
31,100
10,900
20,500
5,800
2,000
Tasa de Energía, Btu/h
Tarifa de Ganancia de Calor, Btu/h
Radiante Convectivo
Latente
Total
Sensible
Sensible
400
800
0
1,200
700
2,800
0
3,500
1,200
0
200
1,400
0
900
3,000
3,900
200
300
700
1,200
0
0
200
200
300
400
0
700
400
800
0
1,200
300
600
2,600
3,500
500
600
0
1,100
900
1,500
0
2,400
900
2,100
0
3,000
900
1,600
0
2,500
900
1,800
600
3,300
0
0
0
0
2,200
10,400
0
12,600
1,200
2,000
0
3,200
100
100
0
200
0.18
0.51
0.08
0.27
0.09
0.12
0.06
0.15
0.69
0.41
0.71
0.79
0.08
0.11
0.00
0.61
0.55
0.10
Factor de
Uso FU
Tarifas Recomendadas de Ganancia de Calor Radiante y Convectivo de Artefactos Eléctricos Cubiertos
durante Condiciones Libres (Listo para cocinar) [2013F, Ch 18, Tbl 5A]
Artefacto
Tabla 12.22 (I-P)
Ganancia de calor: qs = qinput FU FR, donde FU es el factor de uso y FR es el factor de radiación.
Utensilios de Cocina
12.fm Page 294 Thursday, March 3, 2016 2:00 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
0.33
0.20
0.86
0.00
0.17
0.00
0.43
0.33
0.09
0.45
0.38
0.30
0.36
0.27
0.00
0.17
0.38
0.50
Factor de
Radiación
FR
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
294
Nominal
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Artefacto
Reserva
Tasa de Energía, Btu/h
Tarifas Recomendadas de Ganancia de Calor Radiante y Convectivo de Artefactos Eléctricos Cubiertos
durante Condiciones Libres (Listo para cocinar) [2013F, Ch 18, Tbl 5A] (Continuo)
Tarifa de Ganancia de Calor, Btu/h
Factor de
Radiante Convectivo
Uso FU
Latente
Total
Sensible
Sensible
Horno de cocción rápida (cuarzo-halógeno)*
41,000
0
0
0
0
0
0.00
Horno de cocción rápida (micro onda//convección)*
24,900
4,100
1,000
3,100
0
1,000
0.16
Armario frigorífico*
4,800
1,200
300
900
0
1,200
0.25
Mesa de preparación refrigerada*
2,000
900
600
300
0
900
0.45
Vapor (panecillo)
5,100
700
600
100
0
700
0.14
Tostadora: 4 rodajas (grande): cocina
6,100
3,000
200
1,400
1,000
2,600
0.49
contacto (vertical)
11,300
5,300
2,700
2,600
0
5,300
0.47
transportador pequeño
32,800
10,300
3,000
7,300
0
10,300
0.31
transportador pequeño
5,800
3,700
400
3,300
0
3,700
0.64
Barquillera
3,100
1,200
800
400
0
1,200
0.39
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos Swierczyna et al. (2008) y (2009).
Tabla 12.22 (I-P)
12.fm Page 295 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
295
0.00
0.24
0.25
0.67
0.86
0.07
0.51
0.29
0.11
0.67
Factor de
Radiación
FR
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Datos de Carga de Aire
Gabinete: servicio caliente (grande), aislado*
Servicio caliente (grande), sin aislamiento
Prueba (grande)*
Prueba (pequeña -15 estantes)
Urna de preparación de café
Calentadores de cajón, 2-cajones (mantener humedad)*
Cocinar huevo
Máquina de café expreso*
Calentador de comida: mesa de vapor (tipo 2 pozos)
Congelador (pequeño)
Rodillo de perro caliente*
Placa caliente: un quemador, alta velocidad
Caja de comida caliente (mantener eco)*
Caja de comida caliente (mantener húmedo)*
Horno microonda: comercial(trabajo duro)
Horno: encimera de hornear con transportador/acabado*
Panini*
Palomitas de maiz*
Horno de cocción rápida (cuarzo-halógeno)*
Horno de cocción rápida (microonda/convección)*
Armario frigorífico*
Reserva
352
1026
410
1143
352
147
205
352
1026
322
703
879
733
967
0
3693
938
59
0
1202
352
Nominal
1993
1993
5099
4191
3810
1202
3194
2403
1495
791
996
1114
9115
9115
3194
6008
1700
586
12 016
7297
1407
Tarifa de Energía, W
Tarifa de Ganancia de Calor, W
Radiante Convectivo
Latente
Total
Sensible
sensible
117
234
0
352
205
821
0
1026
352
0
59
410
0
264
879
1143
59
88
205
352
0
0
59
59
88
117
0
205
117
234
0
352
88
176
762
1026
147
176
0
322
264
440
0
703
264
615
0
879
264
469
0
733
264
528
176
967
0
0
0
0
645
3048
0
3693
352
586
0
938
29
29
0
59
0
0
0
0
293
909
0
293
88
264
0
352
0.18
0.51
0.08
0.27
0.08
0.12
0.06
0.15
0.69
0.41
0.71
0.79
0.08
0.11
0
0.61
0.55
0.1
0
0.16
0.25
Factor de
Uso FU
Tarifas Recomendadas de Ganancia de Calor Radiante y Convectivo de Artefactos Eléctricos Cubiertos
durante Condiciones Libres (Listo para cocinar) [2013F, Ch 18, Tbl 5A]
Artefacto
Tabla 12.22 (SI)
12.fm Page 296 Thursday, March 3, 2016 2:00 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
0.33
0.20
0.86
0.00
0.17
0.00
0.43
0.33
0.08
0.45
0.38
0.30
0.36
0.27
0.00
0.17
0.38
0.50
0.00
0.24
0.25
Factor de
Radiación
FR
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
296
Nominal
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Artefacto
Reserva
Tarifa de Energía, W
Tarifas Recomendadas de Ganancia de Calor Radiante y Convectivo de Artefactos Eléctricos Cubiertos
durante Condiciones Libres (Listo para cocinar) [2013F, Ch 18, Tbl 5A] (Continuo)
Tarifa de Ganancia de Calor, W
Factor de
Radiante Convectivo
Uso FU
Latente
Total
Sensible
sensible
Mesa de preparación refrigerada*
586
264
176
88
0
264
0.45
Vapor (panecillo)
1495
205
176
29
0
205
0.14
Tostadora 4 rebanadas (grande):cocina
1788
879
59
410
293
762
0.49
contacto (vertical)
3312
1553
791
762
0
1553
0.47
transportador (grande)
9613
3019
879
2139
0
3019
0.31
transportador pequeño
1700
1084
117
967
0
1084
0.64
Barquillera
909
352
234
117
0
352
0.39
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos Swierczyna et al. (2008) y (2009).
Tabla 12.22 (SI)
12.fm Page 297 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
297
0.67
0.86
0.07
0.51
0.29
0.11
0.67
Factor de
Radiación
FR
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
12.fm Page 298 Thursday, March 3, 2016 2:00 PM
Artefacto
Tarifa de Energía,
Btu/h
Datos de Carga de Aire
Nominal
Reserva
Tarifa de
Ganancia
de Calor, Factor de Factor de
Radiación
Btu/h
Uso FU
FR
Radiante
Sensible
10,800
0.84
0.35
4,600
0.97
0.39
500
0.02
0.28
1,000
0.06
0.36
500
0.06
0.19
298
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Parrilla: cocción baja 3 pies
36,900
30,900
Fundidor de queso*
12,300
11,900
Freidora: tetera
99,000
1,800
Freidora: grasa profunda abierta, 1-vat 47,800
2,800
Freidora: presión
46,100
2,700
Plancha: doble cara 3 pies (concha de
72,400
6,900
1,400
0.10
0.20
almeja abajo)*
Plancha: doble cara 3 pies (concha de
72,400
11,500
3,600
0.16
0.31
almeja arriba)*
Plancha: plana 3 pies
58,400
11,500
4,500
0.20
0.39
Plancha –pequeña 3 pies*
30,700
6,100
2,700
0.20
0.44
Placa de inducción*
71,700
0
0
0.00
0.00
Wok de inducción*
11,900
0
0
0.00
0.00
Horno: combi: en modo combi*
56,000
5,500
800
0.10
0.15
Horno: combi: modo de convección
56,000
5,500
1,400
0.10
0.25
Horno: convección tamaño completo
41,300
6,700
1,500
0.16
0.22
Horno: convección tamaño medio *
18,800
3,700
500
0.20
0.14
Hervidor de pasta*
75,100
8,500
0
0.11
0.00
Tapa de cocina: tapa quitada/horno
16,600
4,000
1,000
0.24
0.25
prendido*
Tapa de cocina: 3 elementos
51,200
15,400
6,300
0.30
0.41
encendidos/horno prendido
Tapa de cocina: 6 elementos
51,200
33,200
13,900
0.65
0.42
encendidos/horno apagado
Tapa de cocina: 6 elementos
67,800
36,400
14,500
0.54
0.40
encendidos/horno encendido
Cocina: tapa caliente
54,000
51,300
11,800
0.95
0.23
Asador*
37,900
13,800
4,500
0.36
0.33
Salamandra*
23,900
23,300
7,000
0.97
0.30
Caldera de vapor: grande (60 gal) tapa
110,600
2,600
100
0.02
0.04
a fuego lento hacia abajo*
Caldera de vapor: pequeña (40 gal)
73,700
1,800
300
0.02
0.17
tapa a fuego lento hacia abajo*
Vapor, compartimiento: atmosférico* 33,400
15,300
200
0.46
0.01
Sartén basculante/cacerola de estofado 32,900
5,300
0
0.16
0.00
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos Swierczyna et al. (2008) y (2009).
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.23 (I-P) Tarifas Recomendadas de Ganancia de Calor Radiante de
Artefactos Eléctricos Cubiertos durante Condiciones Libres (Listo para Cocinar)
[2013F, Ch 18, Tbl 5B]
12.fm Page 299 Thursday, March 3, 2016 2:00 PM
Artefacto
Tarifa de Energía,
W
Nominal Reserva
299
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Parrilla: cocción baja 900 mm
10 814
9056
Fundidor de queso*
3605
3488
Freidora: cafetera
29 014
528
Freidora: grasa profunda - abierta, 1-vat 14 008
821
Freidora: presión
13 511
791
Plancha: doble cara 900 mm (concha de
21 218
2022
410
0.10
0.20
almeja abajo)*
Plancha: doble cara 900 mm (concha de
21 218
3370
1055
0.16
0.31
almeja arriba)*
Plancha: plana 900 mm
17 115
3370
1319
0.20
0.39
Plancha: pequeña 900 mm*
8997
1788
791
0.20
0.44
Placa de inducción*
21 013
0
0
0.00
0.00
Wok de inducción*
3488
0
0
0.00
0.00
Horno: combi: en modo combi*
16 411
1612
234
0.10
0.15
Horno: combi: modo de convección
16 412
1612
410
0.10
0.25
Horno: convección tamaño completo
12 103
1964
440
0.16
0.22
Horno: convección tamaño medio*
5510
1084
147
0.20
0.14
Hervidor de pasta*
22 010
2491
0
0.11
0.00
Tapa de cocina: tapa quitada/horno
4865
1172
293
0.24
0.25
prendido*
Tapa de cocina: 3 elementos prendidos/
15 005
4513
1846
0.30
0.41
horno apagado
Tapa de cocina: 6 elementos prendidos/
15 005
9730
4074
0.65
0.42
horno apagado
Tapa de cocina: 6 elementos prendidos/
19 870
10 668
4250
0.54
0.40
horno prendido
Cocina: tapa caliente
15 826
15 035
3458
0.95
0.23
Asador*
11 107
4044
1319
0.36
0.33
Salamandra*
7004
6829
2051
0.97
0.30
Caldera de vapor: grande (225 L), tapa
32 414
762
29
0.02
0.04
a fuego lento, bajo *
Caldera de vapor: pequeña (150 L),
21 599
528
88
0.02
0.17
tapa a fuego lento, bajo*
Vapor, compartimento, atmosférico*
9789
4484
59
0.46
0.01
Sartén basculante/cacerola de estofado
9642
1553
0
0.16
0.00
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos Swierczyna et al. (2008) y (2009).
Datos de Carga de Aire
Tarifa de
Ganancia
de Calor, Factor de Factor de
Radiación
W
Uso FU
FR
Radiante
Sensible
3165
0.84
0.35
1348
0.97
0.39
147
0.02
0.28
293
0.06
0.36
147
0.06
0.19
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.23 (SI) Tarifas Recomendadas de Ganancia de Calor Radiante de
Artefactos Eléctricos Cubiertos durante Condiciones Libres (Listo para Cocinar)
[2013F, Ch 18, Tbl 5B]
Datos de Carga de Aire
Artefacto
Tarifa de Ganancia de Calor,
Btu/h (W)
Reserva
Sensible
42,000 (12 309)
6200 (1817)
49,600 (14 536)
7000 (2051)
Factor de Radiation FR
0.15
0.14
Factor de Uso FU
N/A
N/A
Tarifa de Ganancia de Calor, Btu/h (W)
Descubierto
Cubierto
Radiante Convectivo
Radiante
Latente Total
Sensible
Sensible
Sensible
0
4450
13490
17940
0
(0)
(1304)
(3954) (5258)
(0)
0
4750
16970
21720
0
(0)
(1392)
(4973) (6366)
(0)
0
1980
2790
4770
0
(0)
(580)
(818)
(1398)
(0)
0
1980
2790
4770
0
(0)
(580)
(818)
(1398)
(0)
0
2280
4170
6450
0
(0)
(668)
(1222) (1890)
(0)
1040
3010
4850
800
800
(234)
(305)
(882)
(1421)
(234)
500
0
0
0
500
(147)
(0)
(0)
(0)
(147)
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos Swierczyna et al. (2008) y (2009)
Nota; Los valores de carga de calor son prorrateados para 30% lavado y 70% reserva.
Calentador de refuerzo*
Lavavajilla (tipo puerta, desinfección agua caliente)
lavado
Lavavajilla*(tipo contador bajo, desinfección química)
reserva
Lavavajilla* (tipo contador bajo, desinfección agua
caliente) reserva
Lavavajilla (tipo puerta, desinfección química) lavado
Lavavajilla (tipo transportador, desinfección agua
caliente) reserva
Lavavajilla (tipo transportador, desinfección química)
Tarifa de Energía,
Btu/h (W)
Lavado/
Nominal
Reserva
46,800
5700/43,600
(13 716) (1671/12 778)
46,800
5700/N/A
(13 716)
(1671/N/A)
18,400
1200/13,300
(5393)
(352/3898)
18,400
1200/13,300
(5393)
(352/3898)
26,600
1200/18,700
(7796)
(352/5480)
26,600
1700/19,700
(7796)
(498/5774)
130,000
0
(38 099)
(0)
N/A
0
0
0.26
0.00
0
0.26
0.34
0
N/A
0.27
0
0.36
0.35
Factor de
Radiation
FR
Factor de
Uso FU
Tarifas Recomendadas de Ganancias de Calor Convectivo y Radiante de Equipos de Lavado y Desinfección
durante Condiciones Libres (Reservas) o de Lavado [2013F, Ch 18, Tbl 5E]
Artefacto
Tabla 12.25
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos Swierczyna et al. (2008) y (2009)
Tarifa de Energía,
Btu/h (W)
Nominal
40 lb (18 kg)
40 lb (18 kg)
Tarifas Recomendadas de Ganancias de Calor Radiante de Artefactos de Combustible Sólido Cubierto durante Condiciones
Libres (Listo para Cocinar) [2013F, Ch 18, Tbl 5D]
Parrilla: combustible sólido: carbón
Parrilla: combustible sólido: madera(mezquite)*
Tabla 12.24
12.fm Page 300 Thursday, March 3, 2016 2:00 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
300
12.fm Page 301 Thursday, March 3, 2016 2:00 PM
Artefacto
Tarifa de Energía,
Btu/h
Nominal Reserva
95,000
132,000
100,000
96,000
44,000
80,000
80,000
69,200
96,700
87,900
73,900
12,400
4,700
9,000
108,200
8,000
1,800
0.07
0.23
108,200
14,700
4,900
0.14
0.33
90,000
75,700
75,700
44,000
170,000
105,000
56,300
80,000
20,400
6,000
5,800
11,900
68,300
20,500
4,500
23,700
3,700
400
1,000
1,000
7,800
3,500
1,100
0
0.23
0.08
0.08
0.27
0.40
0.20
0.08
0.30
0.18
0.07
0.17
0.08
0.11
0.17
0.24
0.00
7,400
2,000
0.30
0.27
60,100
7,100
0.50
0.12
120,000
120,800
11,500
1.01
0.10
145,000
122,900
13,600
0.85
0.11
99,000
90,000
35,000
35,000
87,400
23,300
500
33,300
5,200
11,500
300
5,300
0.88
0.26
0.01
0.95
0.06
0.49
0.60
0.16
145,000
5,400
0
0.04
0.00
52,000
3,300
300
0.06
0.09
100,000
4,300
0
0.04
0.00
26,000
104,000
8,300
10,400
0
400
0.32
0.10
0.00
0.04
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos
Swierczyna et al. (2008) y (2009).
301
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
25,000
120,000
Datos de Carga de Aire
Parrilla: lote*
Parrilla: cadena (transportador)
Parrilla: sobre cocción (vertical)*
Parrilla: baja cocción 3 pies
Freidora: rosquilla
Freidora: abierto profundo-grasa, 1 tina
Freidora: presión
Plancha: doble cara 3 pies (concha de
almeja abajo)*
Plancha: doble cara 3 pies (concha de
almeja arriba)*
Plancha: plana 3 pies
Horno: combi: en modo combi*
Horno: combi: modo convección
Horno: convección tamaño completo
Horno: transportador (pizza)
Horno: cubierta
Horno: estante mini-rotación*
Hervidor de pasta*
Tapa de cocina: tapa quitada/horno
prendido *
Tapa de cocina: 3 quemadores
prendidos/horno apagado
Tapa de cocina: 6 quemadores
prendidos/horno apagado
Tapa de cocina: 6 quemadores
prendidos/horno prendido
Cocina: wok*
Retermalización*
Olla arrocera*
Salamandra*
Caldera de vapor: grande (60 gal) tapa
a fuego lento baja*
Caldera de vapor: pequeña (10 gal)
tapa a fuego lento baja*
Caldera de vapor: pequeña (40 gal)
tapa a fuego lento
Vapor: compartimento: atmosférico*
Sartén basculante/cacerola de estofado
Tarifa de
Ganancia
de Calor, Factor de Factor de
Radiación
Btu/h
Uso FU
FR
Radiante
Sensible
8,100
0.73
0.12
13,200
0.73
0.14
2,500
0.88
0.03
9,000
0.77
0.12
2,900
0.28
0.23
1,100
0.06
0.23
800
0.11
0.09
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.26 (I-P) Tarifas Recomendadas de Ganancia de Calor Radiante de
Artefactos de Gas Cubierto durante Condiciones Libres (Listo para Cocinar)
[2013F, Ch 18, Tbl 5C]
12.fm Page 302 Thursday, March 3, 2016 2:00 PM
Artefacto
Tarifa de Energía,
W
Datos de Carga de Aire
Nominal Reserva
27 842
38 685
29 307
28 135
12 895
20 280
28 340
25 761
21 658
3634
23 446
1377
322
0.06
0.23
23 446
2638
234
0.11
0.09
31 710
2345
528
0.07
0.23
31 710
4308
1436
0.14
0.33
26 376
22 185
22 185
12 895
49 822
30 772
16 500
23 446
5979
1758
1700
3488
20 017
6008
1319
6946
1084
117
293
293
2286
1026
322
0
0.23
0.08
0.08
0.27
0.40
0.20
0.08
0.30
0.18
0.07
0.17
0.08
0.11
0.17
0.24
0.00
7327
2169
586
0.30
0.27
35 169
17 614
2081
0.50
0.12
35 169
35 403
3370
1.01
0.10
42 495
36 018
3986
0.85
0.11
29 014
26 376
10 257
10 257
25 614
6829
147
9759
1524
3370
88
1553
0.88
0.26
0.01
0.95
0.06
0.49
0.60
0.16
42 495
1583
0
0.04
0.00
15 240
967
88
0.06
0.09
29 307
1260
0
0.04
0.00
7620
30 479
2432
3048
0
117
0.32
0.10
0.00
0.04
*Artículos con un asterisco aparecen sólo en Swierczyna et al. (2009); todos los otros tipos aparecen en ambos
Swierczyna et al. (2008) y (2009).
302
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Parrilla: lote*
Parrilla: cadena (transportador)
Parrilla: sobre cocción (vertical)*
Parrilla: baja cocción 900 mm
Freidora: rosquilla
Freidora: abierto, profundo, grasa
1 tina
Freidora: presión
Plancha: doble cara 900 mm (concha
de almaja abajo)*
Plancha: doble cara 900 mm (concha
de almeja arriba)*
Plancha: plana 900 mm
Horno: combi: en modo combi*
Horno: combi: modo convección
Horno: convección tamaño completo
Horno: transportador (pizza)
Horno: cubierta
Horno: estante mini rotación*
Hervidor de pasta*
Tapa de cocina: tapa quitada/horno
prendido*
Tapa de cocina: 3 quemadores
prendidos/horno apagado
Tapa de cocina: 6 quemadores
prendidos/horno apagado
Tapa de cocina: 6 quemadores
prendidos/horno prendido
Cocina: wok*
Retermalización*
Olla arrocera*
Salamandra*
Caldera de vapor: grande (225 L) tapa a
fuego lento baja*
Caldera de vapor: pequeña(38 L) tapa a
fuego lento baja*
Caldera de vapor: pequeña(150 L) tapa
a fuego lento baja
Vapor: compartimento: atmosférico*
Sartén basculante/cacerola de estofado
Tarifa de
Ganancia
de Calor, Factor de Factor de
Radiación
W
Uso FU
FR
Radiante
Sensible
2374
0.73
0.12
3869
0.73
0.14
733
0.88
0.03
2638
0.77
0.12
850
0.28
0.23
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.26 (SI) Tarifas Recomendadas de Ganancia de Calor Radiante de
Artefactos de Gas Cubierto durante Condiciones Libres (Listo para Cocinar)
[2013F, Ch 18, Tbl 5C]
12.fm Page 303 Thursday, March 3, 2016 2:00 PM
La ganancia de calor varía significativamente. En un laboratorio, la ganancia de calor varía de 15 a
70 Btu·h/pie2 (50 a 220 W/m2). El equipo médico es my variado en tipo y aplicación. La Tabla 12.27
es relevante para equipos portátiles y de tipo banco. Para equipo grande, tal como MRI, obtener la
ganancia de calor del fabricante.
Tabla 12.27 Ganancia de Calor Recomendada de Equipo Médico Típico [2013F, Ch 18m Tbl 6]
Placa, W
250
500
180
360
1440
1000
1688
230
180
1200
330
72
N/A
1800
621
968
1725
2070
Pico, W
177
504
33
204
54
147
605
60
35
256
65
21
198
1063
337
534
Promedio, W
166
221
29
114
50
109
596
59
34
229
63
20
173
1050
302
82
480
18
Fuente: Hosni et al. (1999)
Tabla 12.28 Ganancia de Calor Recomendada de Equipo de Laboratorio Típico [2013F, Ch 18, Tbl 7]
Equipo
Balance Analítico
Centrífuga
Fotómetro de llama
Microscópico fluorescente
Generador de funciones
Incubadora
Agitador orbital
Osciloscopio
Evaporador rotativo
Espectrónicos
Espectrofotómetro
Espectrofluorómetro
Termociclador
Cultivo de tejidos
Pico, W
Promedio, W
7
138
288
5500
50
100
180
150
200
58
515
600
3125
100
72
345
75
94
36
575
200
N/A
340
1840
N/A
475
2346
7
89
136
1176
45
85
107
144
205
29
461
479
1335
16
38
99
74
29
31
106
122
127
405
965
233
132
1178
7
87
132
730
44
84
105
143
178
29
451
264
1222
16
38
97
73
28
31
104
121
125
395
641
198
46
1146
Fuente: Hosni et al. (1999).
303
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Analizador Electroquímico
Placa, W
Datos de Carga de Aire
Equipo
Sistema de anestesia
Manta cálida
Medidor de presión arterial
Sangre cálida
ECG/RESP
Electrocirugía
Endoscopio
Bisturí harmónico
Bomba histeroscópica
Láser sonoro
Microscopio óptico
Oxímetro de pulso
Caminadora de esfuerzo
Sistema de ultrasonido
Succión de vacío
Sistema de rayos X
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Equipo de Hospital y Laboratorio
Fabricante A (modelo A); procesador 2.8 GHz , 1 GB RAM
Fabricante A (modelo B); procesador 2.6 GHz , 2 GB RAM
Fabricante B (modelo A); procesador 3.0 GHz, 2 GB RAM
Fabricante B (modelo B); procesador 3.0 GHz , 2 GB RAM
Fabricante A (modelo C); procesador2.3 GHz , 3 GB RAM
Fabricante 1; procesador 2.0 GHz, 2 GB RAM, 17 in. screen
Manufacturer 1; 1.8 GHz processor, 1 GB RAM, pantalla 17 pulg.
Fabricante 1; procesador 2.0 GHz, 2 GB RAM, pantalla 14 pulg.
Fabricante 2; procesador 2.13 GHz, 1 GB RAM, pantalla 14 pulg., tableta PC
Fabricante 2; procesador 366 MHz, 130 MB RAM (pantalla 4 pulg.)
Fabricante 3; procesador 900 MHz, 256 MB RAM (pantalla 10.5 pulg.)
Fabricante X (modelo A); pantalla 30 pulg.
Fabricante X (modelo B); pantalla 22 pulg.
Fabricante Y (modelo A); pantalla 19 pulg.
Fabricante Y (modelo B); pantalla 17 pug.
Fabricante Z (modelo A); pantalla 17 pulg.
Fabricante Z (modelo C); pantalla 15 pulg.
Descripción
480
480
690
690
1200
130
90
90
90
70
50
383
360
288
240
240
240
Potencia de Placa,
W
73
49
77
48
97
36
23
31
29
22
12
90
36
28
27
29
19
Potencia Promedio,
W
0.10a
0.10a
0.10a
0.10a
0.10a
0.25b
0.25b
0.25b
0.25b
0.25b
0.25b
0.40c
0.40c
0.40c
0.40c
0.40c
0.40c
Fracción
Radiante
Fuente: Hosni and Beck (2008).
a El Consumo de potencia para computadoras de escritorio más recientes en modo operativo varían de 50 a 100 W, pero un valor conservador de alrededor de 65 W puede ser utilizado. . Consumo de potencia en modo de sueño es insignificante. Debido al ventilador de enfriamiento, aproximadamente el 90% de la carga es por convección y el 10% es por radiación. El consumo actual de potencia es alrededor del 10 al 15% del valor de la placa.
b El consumo de potencia de las computadoras portátiles es relativamente pequeño: dependiendo en la velocidad del procesador y el tamaño de la pantalla, varía de alrededor de 15 a 40 W. De esta manera,
diferenciar entre partes radiativas y convectivas de la carga de refrigeración no es necesario y la carga completa puede ser clasificada como convectiva. De otro modo, una fracción de 75/25%.entre componentes radiativo y convectivo puede ser utilizada. El consumo de potencia actual para computadoras portátiles es alrededor del 25% de los valores de placa.
c Los monitores de pantalla plana han reemplazado los monitores de tubos de rayos catódicos (CRT) en muchos lugares de trabajo, proporcionando mejor resolución y siendo mucho más ligeros. El consumo de potencia depende en el tamaño y resolución y va de alrededor de 20W (para tamaño de 15 pulg.) a 90 W (para 30 pulg.). Los tamaños más comunes en lugares de trabajo son de 19 y 22 pulg. para
el cual un promedio delvalor de consume de potencia de 30W puede ser utilizado. Utilice una fracción de 60/40% entre componentes convectivos y radiativos. En modo inactivo, los monitores tienen consumo de potencia insignificante. Los valores de placa no deben utilizarse.
Monitor de pantalla planac
Computadora portátilb
Computadora de Escritorioa
Equipo
Datos de Carga de Aire
Tabla 12.29 (I-P) Ganancia de Calor Recomendada de Equipo Informático Típico [2013F, Ch 18, Tbl 8]
12.fm Page 304 Thursday, March 3, 2016 2:00 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
304
Potencia de Placa,
W
Fabricante A (modelo A); procesador 2.8 GHz , 1 GB RAM
480
Fabricante A (modelo B); procesador 2.6 GHz, 2 GB RAM
480
Fabricante B (modelo A); procesador 3.0 GHz, 2 GB RAM
690
Fabricante B (modelo B); procesador 3.0 GHz, 2 GB RAM
690
Fabricante A (modelo C); procesador 2.3 GHz, 3 GB RAM
1200
Fabricante 1; procesador2.0 GHz, 2 GB RAM, pantalla 430 mm
130
Fabricante 1; procesador 1.8 GHz , 1 GB RAM, pantalla 430 mm
90
Fabricante 1; procesador 2.0 GHz, 2 GB RAM, pantalla 355 mm
90
Fabricante 2; procesador 2.13 GHz, 1 GB RAM, pantalla 355 mm, tableta PC
90
Fabricante 2; procesador 366 MHz , 130 MB RAM (pantalla 355 mm)
70
Fabricante 3; procesador 900 MHz , 256 MB RAM (pantalla 265 mm)
50
Fabricante X (modelo A); pantalla 760 mm
383
Fabricante X (modelo B); pantalla 560 mm
360
Fabricante Y (modelo A); pantalla 480 mm
288
Fabricante Y (modelo B); pantalla 430 mm
240
Fabricante Z (modelo A); pantalla 430 mm
240
Fabricante Z (modelo C); pantalla 380 mm
240
Descripción
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Potencia Promedio,
W
73
49
77
48
97
36
23
31
29
22
12
90
36
28
27
29
19
Fracción
Radiante
0.10a
0.10a
0.10a
0.10a
0.10a
0.25b
0.25b
0.25b
0.25b
0.25b
0.25b
0.40c
0.40c
0.40c
0.40c
0.40c
0.40c
Fuente: Hosni and Beck (2008).
a El Consumo de potencia para computadoras de escritorio más recientes en modo operativo varían de 50 a 100 W, pero un valor conservador de alrededor de 65 W puede ser utilizado. . Consumo de potencia en modo de sueño es insignificante. Debido al ventilador de enfriamiento, aproximadamente el 90% de la carga es por convección y el 10% es por radiación. El consumo actual de potencia es alrededor del 10 al 15% del valor de la placa.
b El consumo de potencia de las computadoras portátiles es relativamente pequeño: dependiendo en la velocidad del procesador y el tamaño de la pantalla, varía de alrededor de 15 a 40 W. De esta manera,
diferenciar entre partes radiativas y convectivas de la carga de refrigeración no es necesario y la carga completa puede ser clasificada como convectiva. De otro modo, una fracción de 75/25%.entre componentes radiativo y convectivo puede ser utilizada. El consumo de potencia actual para computadoras portátiles es alrededor del 25% de los valores de placa.
c Los monitores de pantalla plana han reemplazado a los monitores de tubos de rayos catódicos (CRT) en muchos lugares de trabajo, proporcionando mejor resolución y siendo mucho más ligeros. El consumo de potencia depende en el tamaño y resolución y va de alrededor de 20W (para tamaño de 380 mm.) a 90 W (para 760 mm.). Los tamaños más comunes en lugares de trabajo son de 480 y 560 mm.
para el cual un promedio del valor de consume de potencia de 30W puede ser utilizado. Utilice una fracción de 60/40% entre componentes convectivos y radiativos. En modo inactivo, los monitores
tienen consumo de potencia insignificante. Los valores de placa no deben utilizarse.
Monitor de pantalla plana c
Computadora portátilb
Computadora de escritorioa
Equipo
Tabla 12.29 (SI) Ganancia de Calor Recomendada de Equipo Informático Típico [2013F, Ch 18, Tbl 8]
12.fm Page 305 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
305
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
12.fm Page 306 Thursday, March 3, 2016 2:00 PM
Datos de Carga de Aire
Potencia de
Placa, W
Potencia
Promedio, W
Fracción
Radiante
430
137
0.30a
890
74
0.30a
508
88
0.30a
508
98
0.30a
635
110
0.30a
1344
130
0.30a
600
40
30
15
d
d
Media, tipo escritorio
700
135
d
Pequeño, tipo escritorio
Grande, multiuso, tipo de
oficina
19
16
d
Equipo
Descripción
Impresora láser,
escritorio típico,
tipo oficina
pequeñaa
Velocidad de impresión hasta
10 páginas por minuto
Velocidad de impresión hasta
35 páginas por minuto
Velocidad de impresión hasta
19 páginas por minuto
Velocidad de impresión hasta
17 páginas por minuto
Velocidad de impresión hasta
19 páginas por minuto
Velocidad de impresión hasta
24 páginas por minuto
Pequeña, tipo escritorio
Multifunción
(copia,
impresión,
escaneo)b
Escánerb
Máquina
copiadorac
1750
1440
1850
936
40
400
456
Fuente: Hosni and Beck (2008).
a Varias impresoras láser, disponibles y comúnmente utilizadas en oficinas personales fueron probadas para consumo
de potencia en modo de impresión, los cuales variaron de 75 a 140 W, dependiendo en el modelo, la capacidad de
impresión y velocidad. El consumo de potencia promedio de 110 W puede ser utilizado. La división entre convección y radiación es aproximadamente 70/30%.
b Los sistemas pequeños de multifunción (copia, escaneo, impresión) utilizan alrededor de 15 a 30 W, los de tamaño
medio utilizan alrededor de 135 W. . El consuo de potencia en modo inactivo es insignificante. Los valores de
placa no representan el consumo de potencia actual y no deberían utilizarse Escáner pequeños de una sola hoja
consumen menos de 20 W y no contribuyen significativamente a la carga de refrigeración de un edificio.
c El consumo de potencia para máquinas copiadoras grandes en oficinas grandes y centros de copia van desde alrededor de 550 a 1100 W en modo de copia. El consumo en modo inactivo varía desde alrededor de 130 a 300 W.
Contar el consumo de energía en modo inactivo como en su mayoría por convección en cálculos de carga de refrigeración.
d La división entre ganancia de calor convectiva y radiante no fue determinada para estos tipos de equipo.
306
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Máquina de fax Media
Pequeña
Trazador
Fabricante A
Fabricante B
800 (inactivo
d (inactivo 0.00c)
260 W)
550 (inactivo
d (inactivo 0.00c)
135 W)
1060 (inactivo
d (inactivo 0.00c)
305 W)
90
d
20
d
250
d
140
d
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.30 Ganancia de Calor Recomendada de
Impresoras Láser Típicas y Copiadoras [2013F, Ch 18, Tbl 9]
12.fm Page 307 Thursday, March 3, 2016 2:00 PM
Equipo
Cafetera, 10 tazas
Lector de microficha
Lector de micropelícula
Lector de micropelícula/impresora
Horno microonda, 1 pie3 (28 L)
Trituradora de papel
Enfriador de agua, 32 qt/h (30 L/h)
Tasa Recomendada de
Ganancia de Calor, W
125
600 a 3300
600 a 6600
230
80
390 a 2150
390 a 4300
150
72
1150 a 1920
1725
240 a 275
72
575 a 960
862
240 a 275
440
60
370
48
4800
1500
85
520
1150
600
250 a 3000
700
Datos de Carga de Aire
Equipo de procesamiento de correo
Máquina Plegadora
Máquina de inserción, 3600 a 6800 piezas/h
Máquina rotuladora, 1500 a piezas/h
Medidor de franqueo
Máquinas expendedoras
Cigarrillo
Comida fría/bebidas
Bebidas calientes
Bocadillo
Otras
Impresora de código de barras
Cajas registradoras
Estación de trabajo de procesamiento
de cheques,12 bolsas
Capacidad de
Entrada Máxima, W
2470
1050 sensible,
1540 Btu/h (450 W) latent
85
520
1150
400
200 a 2420
350
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
307
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.31 Ganancia de Calor Recomendada de Equipo de Oficina Misceláneo
[2013F, Ch 18, Tbl 10]
12.fm Page 308 Thursday, March 3, 2016 2:00 PM
Factor
deCarga,
W/pie2
Datos de Carga de Aire
Tipo de Uso
100% Computadora
portátil, liviana
0.25
Media
0.33
50% Computadora
portátil, liviana
0.40
Media
0.50
100% Computadora de
escritorio
0.60
Medium
0.80
100% Computadora de
escritorio, dos monitores
100% Computadora de
escritorio, pesada
1.00
100% Computadora de
escritorio, en pleno
2.00
1.50
Descripción
167 pie2/estación de trabajo, todo uso computador portátil, 1 impresora
por 10, altavoces, misceláneos.
125 pie2/estación de trabajo, todo uso computador portátil, 1 impresora
por 10, altavoces, misceláneos.
167 pie2/estación de trabajo, 50% computador portátil/50%
computadora de escritorio, 1 impresora por 10, altavoces, misceláneos.
125 pie2/estación de trabajo, 50% computador portátil/50%
computadora de escritorio, 1 impresora por 10, altavoces, misceláneos
167 pie2/estación de trabajo, todo uso computadora de escritorio,
1 impresora por 10, altavoces, misceláneos.
125 pie2/estación de trabajo, todo uso computadora de escritorio,
1 impresora por 10, altavoces, misceláneos.
125 pie2/estación de trabajo, todo uso computadora de escritorio,
2 monitores, 1 impresora por 10, altavoces, misceláneos.
85 pie2/estación de trabajo, todo uso computadora de escritorio,
2 monitores, 1 impresora por 8, altavoces, misceláneos.
85 pie2/estación de trabajo, todo uso computadora de escritorio,
2 monitores, 1 impresora por 8, altoparlantes, misceláneos, no
diversidad.
Fuente: Wilkins and Hosni (2011).
Tabla 12.32 (SI) Factores de Carga Recomendados para Varios Tipos de Oficinas
[2013F, Ch 18, Tbl 11]
Factor
deCarga,
W/m2
Tipo de Uso
100% Computadora
portátil, liviana
2.69
Media
3.55
4.31
Media
5.38
100% Computadora de
escritorio, liviana
6.46
Media
8.61
100% Computadora de
escritorio, dos monitores
100% Computadora de
escritorio, pesada
100% Computadora de
escritorio, en pleno
10.76
16.15
21.52
Fuente: Wilkins and Hosni (2011).
Tabla 12.33 Factores de Diversidad Recomendados para Equipo de Oficina
[2013F, Ch 18, Tbl 12]
Dispositivo
Factor de Diversidad Recomendado
Computadora de escritorio
75%
Monitor LCD
60%
Ordenador portátil
75%
308
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
50% Computadora
portátil, liviana
Descripción
15.5 m2/estación de trabajo, todo uso computadora portátil, 1 impresora
por 10, altavoces, misceláneos.
11.6 m2/estación de trabajo, todo uso computadora portátil, 1 impresora
por 10, altavoces, misceláneos.
15.5 m2/estación de trabajo, 50% computadora portátil/50%
computadora de escritorio, 1 impresora por 10, altavoces, misceláneos.
11.6 m2/estación de trabajo, 50% computadora portátil/50%
computadora de escritorio, 1 impresora por 10, altavoces, misceláneos.
15.5 m2/estación de trabajo, todo uso computadora de escritorio,
1 impresora por 10, altavoces, misceláneos.
11.6 m2/estación de trabajo, todo uso computadora de escritorio,
1impresora por10, altavoces, misceláneos.
11.6 m2/estación de trabajo, todo uso computadora de escritorio,
2 monitores, 1 impresora por 10, altavoces, misceláneos.
7.9 m2/estación de trabajo, todo uso computadora de escritorio,
2 monitores, 1 impresora por 8, altavoces, misceláneos.
7.9 m2/estación de trabajo, todo uso computadora de escritorio,
2 monitores, 1 impresora por 8, altavoces, misceláneos no diversidad.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.32 (I-P) Factores de Carga Recomendados para Varios Tipos de Oficina
[2013F, Ch 18, Tbl 11]
12.fm Page 309 Thursday, March 3, 2016 2:00 PM
Tipo de Accesorio Expuesto
Btu/h·ft de Accesorio*
Calor Latente Calor Sensible Efecto de Refrigeración Total
38
70
144
322
400
207
400
576
1288
1600
245
470
720
1610
2000
64
70
366
400
430
470
52
219
298
876
350
1095
196
784
980
36
192
204
768
240
960
Datos de Carga de Aire
Temperatura baja
Comida congelada
Cubierta individual
Cubierta individual, doble isla
2 Cubiertas
3 Cubiertas
4 ó 5 Cubiertas
Helado
Una cubierta
Una cubierta, doble isla
Temperatura estándar
Carnes
Cubierta individual
Cubierta múltiple
Lechería
Cubierta múltiple
Producir
Cubierta individual
Cubierta múltiple
* Estas figuras son magnitudes generales para accesorios ajustados para temperaturas promedio de productos deseados y aplican a ambientes de tiendas delante de las vitrinas de 72°F a 74°F con 50% a 55% rh. Elevar el bulbo seco de 3°F a 5°F y la
humedad de 5% a 10% puede incrementar la remoción de calor 25% ó más. Temperaturas igualmente inferiores y humedades como en invierno, tienen un efecto igualmente marcado en la reducción de la eliminación de calor desde el espacio.
Tabla 12.34 (SI) Efecto de Refrigeración Producido
por Accesorios Expuestos Refrigerados Abiertos
Tipo de Accesorio Expuesto
36
67
138
310
384
199
384
554
1238
1538
236
452
692
1540
1923
62
67
352
384
413
452
50
211
286
842
336
1053
188
754
942
35
184
196
738
231
923
* Estas figuras son magnitudes generales para accesorios ajustados para temperaturas promedio de productos deseados y aplican a ambientes de tiendas delante de las vitrinas de 22°C a 23°C con 50% a 55% rh. Elevar el bulbo seco de 2°C a 3°C y la
humedad de 5% a 10% puede incrementar la remoción de calor 25% ó más. Temperaturas igualmente inferiores y humedades como en invierno, tienen un efecto igualmente marcado en la reducción de la eliminación de calor desde el espacio.
309
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Temperatura baja
Comida congelada
Cubierta individual
Cubierta individual, doble isla
2 Cubiertas
3 Cubiertas
4 ó 5 Cubiertas
Helado
Cubierta individual
Cubierta individual, doble isla
Temperatura estándar
Carnes
Cubierta individual
Cubierta múltiple
Lechería
Cubierta múltiple
Producir
Cubierta individual
Cubierta múltiple
W/m de accesorio*
Calor Latente Calor Sensible Efecto de Refrigeración Total
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 12.34 (I-P) Efecto de Refrigeración Producido por
Accesorios Expuestos Refrigerados Abiertos
13.fm Page 310 Thursday, March 3, 2016 2:04 PM
VENTILACIÓN
Norma 62.2-2010 de ASHRAE, Ventilación y Calidad de Aire Interior
Aceptable en Edificios Residenciales de Baja Altura
(Ver la norma completa para orientación detallada)
Ventilación residencial de baja altura para estructuras familiares múltiples e individuales de
tres pisos o menos grado o superior, incluyendo casas fabricadas y modulares. Cuyos sistemas de
ventilación mecánica son requeridos para cada unidad de vivienda:
Ventilación
cfm = 0.01 (pie2 área de piso) + 7.5 (número de habitaciones + 1)
(L/s = 0.05 (m2 área de piso) + 3.5 (número de habitaciones + 1)
Excepciones: (a) el edificio no tiene enfriamiento mecánico y está en la zona 1 ó 2 del mapa
de zona climático (ver Figura 14.1) ó (b) el edificio está térmicamente acondicionado para ocupación humana para menos de 876 horas por año y si la autoridad que tiene jurisdicción determina
que la ventilación de la ventana es suficiente.
Maneras alternativas pueden utilizarse para proporcionar la tasa de ventilación requerida
cuando es aprobada por un licenciado profesional de diseño. En calor, climas húmedos, el escape
mecánico neto para toda la casa no excederá 7.5 cfm por 100 pie2 (35 L/s por 100 m2). En climas
fríos severos, sistemas de suministro neto no excederán 7.5 cfm por 100 pie2 (35 L/s por 100 m2).
(Los climas están definidos en la Figura 14.1.)
Las tasas de extracción mecánica local están mostradas en las Tablas 13.1 y 13.2
Aberturas de ventilación: no menos del 4% del piso, no menos de 5 pie2 (0.5 m2) por cuartos
habitables; y no menos de 4% del espacio del piso, no menos de 1.5 pie2 (0.15 m2) para retretes y
cuartos de servicio.
Los conductos de suministro para acondicionadores térmicos excepto enfriadores evaporativos, tendrán un filtro MERV 6 ó mejor de acuerdo con la Norma 52.2 de ASHRAE.
Las corrientes de aire se refieren todos a la corriente de aire entregada como prueba, o la
capacidad de los ventiladores a 0.25 pulg. w.g.(62.5 Pa) con el tamaño del conducto que cumpla
con el tamaño prescriptivo de la Tabla 13.3.
Tabla 13.1 Tasas de Corriente de Aire de Escape de
Ventilación Local Intermitente [Std 62.2-2010, Tbl 5.1]
Aplicación
Corriente de Aire
Notas
Campana de cocina con ventilación (incluyendo combinaciones de la
100 cfm (50 L/s) campana de cocina y artefactos) requeridos si la tasa de flujo del
ventilador de escape es menor a 5 cambios de aire de cocina por hora.
Cuarto de Baño 50 cfm (25 L/s)
Cocina
Aplicación
Cocina
Cuarto de Baño
Flujo de Aire
5 ach
20 cfm (10 L/s)
Notas
Basado en volumen de la cocina.
Tabla 13.3 Dimensionamiento de Conductos Prescriptiva [Std 62.2-2010, Tbl 5.3]
Tipo de Conducto
Capacidad del ventilador
cfm @ 0.25 in. w.g.
(L/s @ 62.5 Pa)
Diámetro, in. (mm)
3 (75)
4 (100)
5 (125)
6 (150)
7 (175) y más allá
Conducto Flexible
50
(25)
80
(40)
Conducto Liso
100
(50)
125
50
80
100
125
(65)
(25)
(40)
(50)
(65)
Longitud Máxima, ft (m)
X
X
X
X
5 (2)
X
X
X
70 (21) 3 (1)
X
X
105 (32) 35 (11) 5 (2)
X
NL 70 (21) 35 (11) 20 (7)
NL 135 (42) 85 (26) 55 (17)
NL
NL 135 (42) 95 (29)
NL
NL
NL 145 (45)
NL
NL
NL
NL
NL
NL
NL
NL
Esta tabla no asume codos. Deducir 15 pie (5 m) de longitud de conducto admisible para cada codo.
NL = sin límite en la longitud del conducto de este tamaño.
X = no permitido, cualquier longitud de conducto de este tamaño con giros y accesorios asumidos excederán la caída de la presión
nominal.
310
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tabla 13.2 Tasas de Corriente de Aire de Escape de Ventilación Local Continua
[Std 62.2-2010, Tbl 5.2]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
13.
13.fm Page 311 Thursday, March 3, 2016 2:04 PM
(Ver norma completa para guía detallada.)
General
311
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 13.1 Sistema de Ventilación [Std 62. 1-2010, Fig. 3.1]
Ventilación
La utilización de sistemas de ventilación natural es permitida en vez de o conjuntamente con
ventilación mecánica. Espacios naturalmente ventilados estarán permanentemente abiertos a pared
manejable o aberturas de techo al aire libre; área libre de abrir por lo menos 4% del área neta de
piso ocupable. Si los espacios interiores son ventilados a través de cuartos adjuntos, el área libre
entre cuartos deberá estar permanentemente sin obstáculo y por lo menos el 8% del área del cuarto
interior, no menos de 25 pie2 (2.3 m2). Los ocupantes deben tener acceso inmediato a las aberturas.
Todas las superficies de corriente de aire serán diseñadas para resistir crecimiento de moho y
resistir erosión. La construcción de canalización debe reunir las normas de SMACNA. Los artefactos que queman combustible deben tener aire suficiente para combustión y remoción adecuada
de productos de combustión, que deben ser ventilados directamente al aire libre. Los filtros o depuradores de aire con un mínimo MERV 6 por la Norma 52.2 de ASHRAE deberán ser provisto
aguas arriba de todos los serpentines refrigerantes u otros dispositivos con superficies húmedas a
través de la cual el aire es suministrado a espacios ocupables. La humedad relativa debe estar bajo
65% cuando el rendimiento del sistema es analizado con el aire libre en el punto de rocío de
diseño y la media de bulbo seco coincidente, cargas interiores de espacios sensibles y latentes en
valores de diseño de enfriamiento y cargas solares del espacio en cero. El mínimo declive de las
bandejas de drenaje 1/8 pulg. por pie (10 mm por metro) a la salida en el punto más bajo y la línea
de drenaje tendrán trampa P u otro sello cuando la bandeja de drenaje está en presión estática negativa respecto a la salida. La bandeja de drenaje se extenderá del borde delantero de la bobina a
una distancia de la mitad de la dimensión vertical de la bobina.
La descarga de equipo de no combustión que captura contaminantes generados por el equipo
será descargada directamente al aire libre.
Investigar la calidad de aire del exterior. Encuestar y documentar la calidad de aire exterior local,
con descripción de problemas de aire notables y condiciones referente a su aceptabilidad. Si no es aceptable, trátelo. La limpieza para ozono se requiere solamente si en un área de alto ozono (ver Apéndice E
de la norma) y si el diseño mínimo de corriente de aire exterior es 1.5 de cambios de aire o más.
Las entradas de aire exterior deben estar situadas de modo que la distancia más corta de la
entrada a cualquier fuente contaminante específico igualará o excederá la Norma 62.1 de
ASHRAE Tabla 5-1.
Diseñar la entrada para controlar la lluvia y arrastre de nieve e incluir alambreras para pájaros.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Norma 62.1-2010 de ASHRAE, Ventilación para Calidad de Aire Interior
Aceptable
13.fm Page 312 Thursday, March 3, 2016 2:04 PM
Distancia de Separación Mínima de Entrada de Aire
[Std 62.1-2010, Tbl 5-1]
Objeto
Clase 2 escape de aire/ salida de alivio (Nota 1)
10 (3)
Clase 3 escape de aire/salida de alivio (Nota 1)
15 (5)
Clase 4 escape de aire/salida de alivio (Nota 2)
30 (10)
Respiraderos de instalación sanitaria 3 pie (1 m) sobre el nivel de la entrada
de aire exterior
Respiraderos de instalación sanitaria terminando menos de 3 pie (1 m) sobre
el nivel de la entrada de aire exterior
Respiraderos, chimeneas y humos de artefactos de combustión y equipos
(Nota 3)
10 (3)
3 (1)
15 (5)
Entrada de garaje, área de carga de automóvil, o fila para drive-in (Nota 4)
15 (5)
Zona de carga de camiones o muelle, parqueadero de buses/área de marcha
lenta (Nota 4)
25 (7.5)
Entrada de carros, calle o lugar de paqueo (Nota 4)
5 (1.5)
Carretera con alto volumen de tráfico
25 (7.5)
Techo, grado de paisaje u otra superficie directamente bajo la entrada
(Notas 5 y 6)
1 (0.30)
Almacenamiento de basura/ zona de recolección, contenedores
Ventilación
Distancia Mínima,
ft (m)
Entrada de torre de enfriamiento o pileta
Escape de torre de enfriamiento
15 (5)
15 (5)
25 (7.5)
Clasificaciones de aire:
• Clase 1: Aire con baja concentración de contaminantes, baja intensidad de irritación sensorial y olor inofensivo.
• Clase 2: Aire con concentración moderada de contaminantes, leve intensidad de
irritación sensorial, u olores levemente ofensivos. El aire de Clase 2 también incluye aire
que no es necesariamente perjudicial u objetable pero que es inapropiado para transferencia o recirculación a espacios utilizados para diferentes propósitos.
• Clase 3: Aire con significante concentración de contaminantes, significante intensidad
de irritación sensorial u olor ofensivo.
Clase 4: Aire con gases o humos altamente objetables o con partículas potencialmente dañinas, bio-aerosoles, o gases en concentraciones lo suficientemente altas para ser consideradas
dañinas.
312
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota 1: Estos requisitos aplican a la distancia de las salidas de aire exterior por un sistema de ventilación a las salidas
de escape/alivio para cualquier otro sistema de ventilación.
Nota 2: La distancia mínima indicada no aplica a las salidas de aire de escape de las campanas de humo de laboratorio. Los criterios de separación para escape de la campana de humo deben estar en conformidad con NFPA 455 y
ANSI/AIHA Z9.56. La información sobre criterios de separación para ambientes industriales pueden encontrarse
en el Manual de Ventilación Industrial7 ACGIH y en el Manual de ASHRAE — Aplicaciones HVAC.8
Nota 3: Distancias de separación más cortas serán permitidas cuando están determinadas de acuerdo con (a) ANSI
Z223.1/NFPA 549 para equipos y artefactos que queman gas combustible, (b) NFPA 3110 para equipos y artefactos que queman aceite, o (c) NFPA 21111 para otros equipos y artefactos de combustión.
Nota 4: Distancia medida a los lugares más cercanos que el escape de vehículos es probable ser localizado.
Nota 5: Distancia de separación más corta sera permitida donde la superficies exteriores están inclinadas más de 45
grados horizontal o que son menores de 1 pulg. (3 cm) de amcho.
Note 6: Where snow accumulation is expected, the surface of the snow at the expected average snow depth constitutes the “other surface directly below intake.”
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 13.4
13.fm Page 313 Thursday, March 3, 2016 2:04 PM
Corrientes de Aire [Std 62.1-2010, Tbl 5-2]
Clase de Aire
4
4
3
4
3
2
El Procedimiento de la Tasa de Ventilación, el Procedimiento de Ventilación Natural o el Procedimiento de Calidad de Aire Interior (IAQ) deberán utilizarse para diseñar los sistemas de ventilación. El Procedimiento de Calidad de Aire Interior (IAQ) está basado en el análisis de fuentes
contaminantes, concentraciones y objetivos y aceptabilidad percibida de objetivos. Utilice técnicas
de diseño que puedan ser demostradas en forma fiable para dar lugar a concentraciones de contaminantes interiores igual a o inferior que lo obtenido por el procedimiento de tasa de ventilación.
Procedimientos de la Norma 62.1-2010 de ASHRAE
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
313
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Ventilación
6.2 Procedimiento de Tasa de Ventilación. El flujo de la toma de aire exterior (Vot) para un
sistema de ventilación deberá ser determinado de acuerdo con las Secciones 6.2.1 a la 6.2.7.
Nota: Explicación adicional de términos utilizados abajo está contenido en el Apéndice A,
junto con un esquema de sistema de ventilación esquemático (Figura A-1).
6.2.1 Tratamiento de Aire Exterior. Si el aire exterior es juzgado de ser inaceptable de acuerdo con la Sección 4.1, cada sistema de ventilación provee aire exterior a través de un ventilador
de suministro que deberá cumplir con las siguientes secciones:
Excepción: Los sistemas que suministran aire para estacionamientos encerrados, bodegas, cuartos
de almacenaje, armarios de conserjes, cuartos de basura, área de reciclaje, áreas de embarque/
recepción/distribución.
Nota: Espacios ocupados ventilados con aire exterior que es juzgado ser inaceptable están
sujetos a reducir la calidad de aire cuando el aire exterior no es limpiado antes de la introducción
a los espacios ocupados.
6.2.1.1 Partículas más Pequeñas que 10 Micrómetros (PM10). Cuando el edificio está
situado en un área donde la norma nacional o pauta para PM101 está excedido, filtros de partículas
o dispositivos de limpieza de aire deben ser suministrados para limpiar el aire del exterior en cualquier sitio antes de su introducción a espacios ocupados. Filtros de partículas o depuradores de
aire tendrán un Valor de Informe de Eficiencia Mínima (MERV) de 6 o más alto cuando están calificados de acuerdo con la Norma 52.2.15 de ANSI/ASHRAE.
Nota: Ver Apéndice E para recursos relacionados con PM10 seleccionado de normas nacionales y pautas.
6.2.1.2 Partículas Más Pequeñas que 2.5 Micrómetros (PM2.5), Cuando la construcción
está situada en un área donde la norma nacional o pauta para PM2.51 está excedida, filtros de
partículas o dispositivos depuradores de aire deben ser suministrados para limpiar el aire exterior
en cualquier sitio antes de su introducción a espacios ocupados. Filtros de partículas o depuradores de aire tendrán un Valor de Informe de Eficiencia Mínima (MERV) de 11 o más alto cuando
especificado de acuerdo con la Norma de ASHRAE 52.2.15
Nota: Ver Apéndice E para recursos relacionados con las pautas y normas nacionales seleccionadas PM2.5.
6.2.1.3 Ozono. Dispositivos depuradores de aire para ozono serán proporcionados cuando el
más reciente promedio de tres años cuarto anual más alto diario máximo de ocho horas promedio
de concentración de ozono excede 0.107 ppm (209 µg/m3).
Nota: Ver Apéndice E para una lista de ubicaciones en Estados Unidos que exceden el más
reciente promedio de tres años cuarto anual más alto diario máximo de ocho horas promedio de
concentración de ozono de 0.107 ppm.
Tales dispositivos depuradores de aire tendrán una eficiencia de remoción de ozono volumétrica
mínima de 40% cuando es instalado, operado y mantenido de acuerdo con las recomendaciones del
fabricante y serán aprobadas por la autoridad que tiene jurisdicción. Tales dispositivos deben ser
operados cuando los niveles de ozono exterior se espera que excedan 0.107 ppm (209 µg/m3).
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 13.5
Descripción
Descarga de equipo de impresión Diazo
Campanas de grasa de cocina comercial
Campanas de cocina comercial aparte de la grasa
Campanas de laboratorio
Campanas de ventilación de cocina residencial
Cuarto de máquinas de ascensor hidráulico
13.fm Page 314 Thursday, March 3, 2016 2:04 PM
6.2.1.4 Otros Contaminantes Exteriores. Cuando el edificio está situado en un área donde
la norma nacional para uno o más contaminantes no abordado específicamente en la Sección 6.2.1
está excedida, cualquier asunción de diseño y/o cálculos relacionados al impacto en la calidad de
agua interior debe ser incluida en los documentos de diseño.
6.2.2 Cálculos de Zona. Los parámetros de la zona de ventilación serán determinados de acuerdo
con la Sección 6.2.2.1 a la 6.2.2.3 para cada zona de ventilación servida por el sistema de ventilación.
6.2.2.1 Corriente de Aire Exterior de la Zona de Respiración. La corriente de aire exterior
requerida en la zona de respiración del espacio ocupable o espacios en una zona de ventilación, ej.
la corriente de aire exterior de la zona de respiración (Vbz), será no menor que el valor determinado de acuerdo con la Ecuación 6-1.
Vbz = Rp · Pz + Ra · Az
(6-1)
donde
Az =
Pz =
Rp =
Ventilación
Ra
=
zona de área de piso; el área neta del piso ocupable de la zona de ventilación pie2 (m2)
zona de población; el número de gente en la zona de ventilación durante uso típico
tasa de corriente de aire exterior requerido por persona como está determinado en la Tabla 6-1
Nota: Estos valores están basados en ocupantes adaptados.
la tasa de corriente de aire exterior requerida por área de unidad como determinada de la
Tabla 6-1
6.2.2.2 Eficacia de Distribución de Aire de la Zona. La eficacia de distribución de aire de la
zona (Ez) no debe ser mayor que el valor de infracción determinado utilizando la Tabla 6-2.
Nota: Para algunas configuraciones, el valor de infracción depende del espacio y la temperatura de aire suministrado.
6.2.2.3 Corriente de Aire Exterior de la Zona. La zona de corriente de aire exterior (Voz),
ej. la tasa de corriente de aire exterior que debe ser suministrada a la zona de ventilación por el
sistema de distribución de aire de suministro, será determinada de acuerdo con la Ecuación 6-2.
Voz = Vbz/Ez
(6-2)
6.2.3 Sistemas de Una Zona. Para sistemas de ventilación donde uno o más transportadores
de aire suministran solo aire exterior y aire recirculado sólo a una zona de ventilación, el flujo de
entrada de aire exterior (Vot) será determinado de acuerdo con la Ecuación 6-3.
Vot = Voz
(6-3)
6.2.4 Sistemas de Aire Exterior 100%. Para sistemas de ventilación donde uno o más transportadores de aire suministran sólo aire exterior a una o más zonas de ventilación, el flujo de
entrada de aire exterior (Vot) será determinado de acuerdo con la Ecuación 6-4.
Vot = all zonesVoz
314
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
(6-4)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota: La Ecuación 6-1 da razón de fuentes de gente relacionada y fuentes de área relacionada
independientemente en la determinación de la tasa de aire exterior requerida en la zona de respiro.
El uso de la Ecuación 6-1 en el contexto de esta norma no necesariamente implica que un aumento
simple de las tasas de corriente de aire exterior de fuentes diferentes pueda ser aplicado a cualquier otro aspecto de calidad de aire interior.
6.2.2.1.1 Diseño de la Zona de Población. El diseño de la zona de población (Pz) igualará el
número de gente más grande (pico) esperado ocupar la zona de ventilación durante el uso típico.
Excepción:
a. Si el número de gente esperada a ocupar la zona de ventilación fluctúa, zona de población
igual al número promedio de personas será permitido, siempre que tal promedio es determinado de acuerdo con la Sección 6.2.6.2.
b. Si el número más grande o promedio de gente espera ocupar la zona de ventilación no
puede ser establecida por un diseño específico, un valor estimado para la zona de
población será permitida, siempre que tal valor es el producto del área neta ocupable de
la zona de ventilación y la densidad de ocupación por defecto indicada en la Tabla 6-1
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Excepción: El depurador de aire para ozono no se requiere cuando:
a. El diseño del sistema mínimo de flujo de entrada de aire exterior resulta en 1.5 ach o menos.
b. Los controles a condición de que el sentido del nivel de ozono exterior y reducir el flujo
de aire de entrada para resultar en 1.5 ach o menos mientras cumplen con los requisitos
del flujo de aire exterior de la Sección 6.
c. El aire exterior es traído dentro del edificio y calentado por fuego directo, unidades de
aire compensatorias.
13.fm Page 315 Thursday, March 3, 2016 2:04 PM
Categoría de Ocupación
Valores en Mora
Area
Densidad Tasa de Aire
de
Gente Tasa de Tasa
de
Aire
Exterior
Aire Exterior Rp Exterior
Clase
Ocupante
Combinada
Notas
(Ver
de
Ra
(Ver Nota 5)
Aire
Nota 4)
#/1000
cfm/
L/s·
cfm/
L/s·
cfm/pie2
pie2
Persona Persona (L/s·m2)
(100 m2) Persona Persona
0.12 (0.6)
0.06 (0.3)
0.06 (0.3)
0.06 (0.3)
25
30
15
50
10
7
9
9
4.9
3.5
4.5
4.4
2
1
1
2
5
0.18 (0.9)
25
17
8.6
2
5
0.18 (0.9)
25
17
8.6
3
5
5
3.8
3.8
5
5
5
5
5
5
5
3.8
0.12 (0.6)
0.12 (0.6)
0.06 (0.3)
0.06 (0.3)
0.18 (0.9)
0.18 (0.9)
0.18 (0.9)
0.18 (0.9)
0.12 (0.6)
0.12 (0.6)
0.06 (0.3)
0.06 (0.3)
25
35
65
150
20
25
25
20
25
25
35
100
15
13
8
8
19
17
17
19
15
15
12
8
7.4
6.7
4.3
4.0
9.5
8.6
8.6
9.5
7.4
7.4
5.9
4.1
1
1
1
1
2
2
2
2
1
1
1
1
3.8
3.8
3.8
3.8
0.18 (0.9)
0.18 (0.9)
0.18 (0.9)
0.12 (0.6)
70
100
100
20
10
9
9
14
5.1
4.7
4.7
7.0
2
2
2
2
2.5
2.5
2.5
—
0.06 (0.3)
0.06 (0.3)
0.06 (0.3)
0.06 (0.3)
25
20
50
—
7
8
6
3.5
4
3.1
1
1
1
1
2.5
0.12 (0.6)
2
65
32.5
2
2.5
2.5
2.5
0.06 (0.3)
0.06 (0.3)
0.12 (0.6)
10
20
10
11
8
17
5.5
4.0
8.5
1
1
2
2.5
0.12 (0.6)
10
17
8.5
1
3.8
2.5
0.06 (0.3)
0.06 (0.3)
30
120
10
6
4.8
2.8
1
1
A
B
315
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
2.5
2.5
2.5
3.8
Ventilación
Instalaciones Correccionales
Celda
5
Sala de estar
5
Estaciones de los guardias
5
Reserva/espera
7.5
Instalaciones Educacionales
Guardería (hasta 4 años)
10
Habitación de enfermo de
10
guardería
Salas de clases (años 5–8)
10
Salas de clases (año 9 y más)
10
Aula de conferencias
7.5
Sala de conferencia (asientos fijos)
7.5
Aula de arte
10
Laboratorios de ciencias
10
Laboratorios universidad/colegio
10
Taller madera/metal
10
Laboratorio de computación
10
Centro de medios
10
Música/teatro/danza
10
Ensamblaje de multiuso
7.5
Servicio de Comida y Bebida
Salas de restaurantes
7.5
Cafeteria/restaurante comida rápida 7.5
Bares, salón de cocteles
7.5
Cocina
7.5
General
Salas de descanso
5
Estaciones de café
5
Conferencia/reunión
5
Corredores
—
Cuartos de almacenaje para
5
líquidos o geles
Hoteles, Moteles, Resorts, Dormitorios
Dormitorio/sala
5
Cuarteles áreas de dormir
5
Lavanderías, central
5
Lavanderías entre unidades de
5
vivienda
Vestíbulos/pre función
7.5
Ensamblaje de usos múltiples
5
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 6-1 Tasas de Ventilación Mínima en Zonas de Respiración
(Esta tabla no es válida en aislación; debe ser utilizada en conjunto con las notas que acompañan.)
13.fm Page 316 Thursday, March 3, 2016 2:04 PM
(Esta tabla no es válida en aislación; debe ser utilizada en conjunto con las notas que acompañan.)
Ventilación
Categoría de Ocupación
Valores en Mora
Area
Densidad Tasa de Aire
de
Gente Tasa de Tasa
de
Aire
Exterior
Aire Exterior Rp Exterior
Clase
Ocupante
Combinada
Notas
(Ver
de
Ra
(Ver Nota 5)
Aire
Nota 4)
#/1000
cfm/
L/s·
cfm/
L/s·
cfm/pie2
pie2
Persona Persona (L/s·m2)
(100 m2) Persona Persona
5
5
2.5
2.5
0.12 (0.6)
0.06 (0.3)
50
10
7
11
3.5
5.5
1
1
5
2.5
0.06 (0.3)
2
35
17.5
1
5
5
5
2.5
2.5
2.5
0.06 (0.3)
0.06 (0.3)
0.06 (0.3)
5
30
60
17
7
6
8.5
3.5
3.0
1
1
1
5
2.5
0.06 (0.3)
5
17
8.5
2
7.5
5
3.8
2.5
0.06 (0.3)
0.06 (0.3)
15
4
12
20
6.0
10.0
1
1
10
5.0
0.18 (0.9)
7
36
18
3
5
5
10
2.5
2.5
5
0.18 (0.9)
0.12 (0.6)
0.12 (0.6)
B
10
10
2
23
17
70
11.5
8.5
35
2
1
2
7.5
3.8
0.12 (0.6)
7
25
12.5
2
—
7.5
10
—
3.8
5
0.00 (0.0)
0.06 (0.3)
0.06 (0.3)
8
4.1
B
—
100
—
1
1
2
5
5
5
5
5
5
7.5
7.5
2.5
2.5
2.5
2.5
2.5
2.5
3.8
3.8
0.06 (0.3)
0.06 (0.3)
0.06 (0.3)
0.06 (0.3)
0.12 (0.6)
0.06 (0.3)
0.12 (0.6)
0.06 (0.3)
150
120
70
50
10
150
40
40
5
6
6
6
17
5
11
9
2.7
2.8
2.9
3.1
8.5
2.7
5.3
4.6
1
1
1
1
1
1
1
1
5
—
2.5
—
0.06 (0.3)
0.06 (0.3)
7.5
7.5
7.5
20
3.8
3.8
3.8
10
0.12 (0.6)
0.06 (0.3)
0.06 (0.3)
0.12 (0.6)
15
40
25
25
16
9
10
25
7.8
4.6
5.0
12.4
2
1
2
2
7.5
3.8
0.18 (0.9)
10
26
12.8
2
7.5
7.5
3.8
3.8
0.06 (0.3)
0.12 (0.6)
8
20
15
14
7.6
7.0
1
2
F,G
F
1
1
316
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Edificios de Oficina
Salas de descanso
Vestíbulos entrada principal
Cuartos de almacenaje ocupables
para materiales secos
Espacio de oficina
Áreas de recepción
Entrada de datos de teléfono
Espacios Misceláneos
Bóvedas de banco/caja de
seguridad
Bancos o vestíbulos bancarios
Computadora (sin impresora)
Fabricación general (excluye
industria pesada y procesos que
usan químicos)
Farmacia (área de preparación)
Estudios de fotografía
Recepción de embarque
Clasificación, embalaje, montaje
liviano
Armarios de teléfonos
Espera de transportación
Bodegas
Espacios de Concurrencia Pública
Área de sentado en auditorio
Lugares de culto religioso
Salas de audiencia
Cámaras legislativas
Bibliotecas
Vestíbulos
Museos (para niños)
Museos/galerías
Residencial
Unidad de vivienda
Corredores comunes
Venta al por Menor
Ventas (excepto como abajo)
Áreas comunes de centro comercial
Peluquería
Salones de belleza y uñas
Tiendas de animales (áreas de
animal)
Supermercado
Lavandería operada por monedas
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 6-1 Tasas de Ventilación Mínima en Zonas de Respiración (Continuo)
13.fm Page 317 Thursday, March 3, 2016 2:04 PM
(Esta tabla no es válida en aislación; debe ser utilizada en conjunto con las notas que acompañan.)
Categoría de Ocupación
Deportes y Entretenimientos
Arena de deporte (área de juego)
Gimnasio,, estadio (area de juego)
Áreas de espectadores
Natación (piscina y terraza)
Disco/pistas de baile
Club de salud/sala de aeróbicos
Club de salud/salas de pesas
Bolera (sentado)
Casinos de juego
Salas de juego
Escenarios/estudios
Valores en Mora
Area
Densidad Tasa de Aire
de
Gente Tasa de Tasa
de
Aire
Exterior
Aire Exterior Rp Exterior
Clase
Ocupante
Combinada
Notas
(Ver
de
Ra
(Ver Nota 5)
Aire
Nota 4)
#/1000
cfm/
L/s·
cfm/
L/s·
cfm/pie2
pie2
Persona Persona (L/s·m2)
(100 m2) Persona Persona
—
—
7.5
—
20
20
20
10
7.5
7.5
10
—
—
3.8
—
10
10
10
5
3.8
3.8
5
0.30 (1.5)
0.30 (1.5)
0.06 (0.3)
0.48 (2.4)
0.06 (0.3)
0.06 (0.3)
0.06 (0.3)
0.12 (0.6)
0.18 (0.9)
0.18 (0.9)
0.06 (0.3)
E
C
D
—
30
150
—
100
40
10
40
120
20
70
8
4.0
21
22
26
13
9
17
11
10.3
10.8
13.0
6.5
4.6
8.3
5.4
1
2
1
2
2
2
2
1
1
1
1
6.2.5 Sistemas de Recirculación de Zona Múltiple. Para sistemas de ventilación donde uno
o más transportadores de aire suministran una mezcla de aire exterior y aire recirculado a más de
una zona de ventilación, el flujo de entrada de aire exterior (Vot) será determinado de acuerdo con
las Secciones 6.2.5.1 a la 6.2.5.4.
6.2.5.1 Fracción de Aire Exterior Primario. La fracción de aire exterior primario (Zpz) será
determinado por zonas de ventilación de acuerdo con la Ecuación 6-5.
Zpz = Voz/Vpz
(6-5)
317
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
ITEM-NOTAS ESPECIFICAS PARA LA TABLA 6-1
A Para bibliotecas de escuela secundaria y universidades, utilizar valores mostrados para Bibliotecas – Espacios de Concurrencia Pública .
B La tasa no puede ser suficiente cuando los materiales almacenados incluyen aquellos que tienen emisiones potencialmente
dañinas.
C La tasa no permite el control de humedad. Ventilación adicional o deshumidificación puede ser requerida para remover
humedad. “Superficie de cubierta” se refiere al área alrededor de la piscina que se espera esté mojada durante el uso normal de la piscina, ej., cuando la piscina está ocupada. El área de la cubierta que se espera que no esté mojada será designada como un espacio tipo (por ejemplo, “área de espectador”).
D La tasa no incluye escape especial para efectos de escenario, ej., vapores de hielo seco, humo.
E Cuando el equipo de combustión es pretendido ser utilizado en la superficie de juego, ventilación de dilución adicional y/
o control de la fuente debe ser suministrado.
F Ocupación por defecto para unidades de vivienda será de dos personas por estudio y unidades de u dormitorio, con una
persona adicional para cada dormitorio adicional.
G El aire de una vivienda residencial no debe ser recirculada o transferida a cualquier otro espacio de esa vivienda.
Ventilación
NOTAS GENERALES PARA LA TABLA 6-1
1 Requisitos relacionados: Las tasas en esta tabla están basadas en todos los otros requisitos aplicables de eta norma que
están cumpliendo.
2 Humo de Tabaco Ambiental: Esta tabla aplica a las áreas libres ETS. Referirse a la Sección 5.17 para requisitos para
construcciones que contengan áreas ETS y áreas libres ETS.
3 Densidad del Aire: Las tasas de corriente de aire volumétricas están basadas en una densidad de aire de 0.075 lbda/pie3
(1.2 kgda/m3), que corresponde a aire seco a una presión barométrica de 1 atm (101.3 kPa) y una temperatura de aire de
70°F (21°C). Las tasas pueden ser ajustadas para densidad actual pero tal ajuste no es requerido para conformidad con
esta norma.
4 Densidad de ocupante por defecto: La densidad de ocupante será utilizada cuando la densidad de ocupante actual no es
conocida.
5 Tasa de aire exterior combinada por defecto (por persona): Esta tasa está basada en la densidad de ocupante por
defecto.
6 Ocupaciones no cotizadas: Si la categoría de ocupación para un espacio propuesto o zona no está cotizado, los requisitos
para la categoría de ocupación cotizada que es más similar en términos de densidad de ocupante, actividades y construcción de edificios deben ser utilizados.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 6-1 Tasas de Ventilación Mínima en Zonas de Respiración (Continuo)
13.fm Page 318 Thursday, March 3, 2016 2:04 PM
Eficacia de Distribución de Aire de la Zona
Ventilación
Ez
1.0
1.0
0.8
1.0
1.0
1.2
1.0
0.7
0.8
0.5
1. “Aire frio” es aire más frio que la temperatura del espacio.
2. “Aire caliente” es el aire más caliente que la temperatura del espacio.
3. “Techo” incluye cualquier punto sobre la zona de respiración. .
4. “Piso” incluye cualquier punto bajo la zona de respiración .
5. Como una alternativa para utilizar los valores de arriba , Ez puede ser considerada como igual a eficacia de cambio
de aire determinada de acuerdo con la Norma 12917 ANSI/ASHRAE para todas las configuraciones de distribución de aire excepto flujo unidireccional.
Vou = Dall zones(Rp · Pz) + all zones(Ra · Az)
(6-6)
6.2.5.3.1 Diversidad de Ocupante. La relación de diversidad de ocupante (D) será determinado de acuerdo con la Ecuación 6-7 para tener en cuenta las variaciones en población dentro de
las zonas de ventilación servidas por el sistema.
D = Ps/all zones Pz,
(6-7)
donde el sistema de población (Ps) es la población total en el área servida por el sistema.
Excepción: Métodos alternativos para dar cuenta de la diversidad de ocupantes serán permitidos,
siempre que el valor resultante de Vou no es menor que el determinado utilizando la Ecuación 6-6.
Nota: La entrada de aire exterior sin corregir (Vou) es ajustado para diversidad del ocupante,
pero no se corrige para la eficacia de la ventilación del sistema.
6.2.5.3.2 Población del Sistema de Diseño. La población del sistema de diseño (Ps) igualará
al más grande número (pico) de gente esperando ocupar todas las zonas de ventilación servidas
por el sistema de ventilación durante uso típico.
318
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
donde Vpz es la zona de corriente de aire primaria, ej., la tasa de corriente de aire primario a la
zona de ventilación del transportador de aire, incluyendo aire exterior y aire recirculado.
Nota: Para propósitos de diseño del sistema VAV, Vpz es el valor de corriente de aire primario
de la zona más baja que se espera en la condición de diseño analizada.
Nota: En algunos casos es aceptable determinar estos parámetros para zonas seleccionadas
solamente como esbozado en la Normativa del Apéndice A.
6.2.5.2 Eficiencia del Sistema de Ventilación. La eficiencia del sistema de ventilación (Ev)
será determinada de acuerdo con la Tabla 6-3 o la Normativa del Apéndice A.
6.2.5.3 Toma de Aire Exterior Sin Corregir. El flujo de la toma de aire exterior sin corregir
(Vou) será determinada de acuerdo con la Ecuación 6-6.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 6-2
Configuración de Distribución de Aire
Suministro de techo de aire frio
Suministro de techo de aire caliente y retorno de piso.
Suministro de techo de aire caliente 15°F (8°C) o más sobe la temperatura del espacio y
retorno al techo.
Suministro de techo de aire caliente menor de 15°F (8°C) sobre la temperatura del
espacio y retorno al techo siempre que 150 fpm (0.8 m/s) chorro de aire de suministro
alcance dentro de 4.5 ft (1.4 m) del nivel del piso. Nota: Para aire de suministro
velocidad más baja, Ez = 0.8.
Suministro de piso de aire frio y retorno de techo siempre que los 150 fpm (0.8 m/s)
chorro de suministro alcance 4.5 pie (1.4 m) ó más sobre el piso. Nota: La mayoría de los
sistemas de distribución de aire bajo el suelo cumplen con esta condición.
Suministro de piso de aire frio y retorno de techo, siempre que la ventilación de
desplazamiento de baja velocidad alcance flujo unidireccional y estratificación térmica.
Suministro de piso de aire caliente y retorno de piso.
Suministro de piso de aire caliente y retorno de techo.
Suministro de compensación dibujado en el lado opuesto de la habitación del escape y/o
del retorno.
Suministro de compensación dibujado cerca del escape y/o lugar de retorno.
13.fm Page 319 Thursday, March 3, 2016 2:04 PM
Eficacia de la Ventilación del Sistema
Ev
1.0
0.9
0.8
0.7
0.6
Use Apéndice A
1. “Max (Zpz)” se refiere al valor más grande de Zpz, calculado utilizando la Ecuación 6-5, entre todas las zonas de
ventilación servidas por el sistema.
2. Para valores de Max (Zpz) entre 0.15 y 0.55, el valor correspondiente de Ev puede ser determinado por la interpolación de los valores en la tabla.
3. Los valores de Ev en esta tabla están basados en una fracción de aire exterior promedio de 0.15 para el sistema (ej.,
la relación de la toma de aire exterior sin corregir (Vou) a la zona total de la corriente de aire primaria para todas las
zonas servidas por el transportador de aire). Para sistemas con valores más altos de la fracción de aire exterior promedio, esta tabla puede resultar en valores bajos irreales de Ev y el uso del Apéndice A puede producir resultados
más prácticos.
Nota: La población del sistema de diseño es siempre igual a o menor que la suma de
población de la zona de diseño para todas las zonas en el área servida por el sistema, debido a que
todas las zonas pueden o no estar simultáneamente ocupadas en la población de diseño.
6.2.5.4 Toma de Aire Exterior. El diseño del flujo de la toma de aire exterior (Vot) será determinada de acuerdo con la Ecuación 6-8.
Vot = Vou/Ev
(6-8)
T = 50v/Vbz
(SI)
(6-9)
6.2.7 Reposición Dinámica. El sistema puede ser diseñado para reponer el flujo de entrada
de aire exterior (Vot) y/o espacio o corriente de aire de la zona de ventilación (Voz) como las condiciones de operación cambien.
6.2.7.1 Ventilación de Control de la Demanda (DCV)
319
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
T = 3v/Vbz (I-P)
donde
T = período de tiempo promedio, min.
v
= el volumen de la zona de ventilación para el cual el promedio está siendo aplicado, pie3 (m3)
Vbz = la corriente de aire exterior de la zona de respiración calculada utilizando la Ecuación 6-1
y valor de diseño de la población de la zona (Pz), cfm (L/s).
Ajustes de diseño aceptable basado en esta provisión opcional incluye lo siguiente:
a. Zonas con ocupación fluctuante: la población de la zona (Pz) puede ser promediada sobre
el tiempo (T).
b. Zonas con interrupción intermitente de aire de suministro: la corriente de aire exterior promedio suministrada a la zona de respiración sobre el tiempo (T) deberá ser no menor que la corriente de aire exterior de la zona de respiración (Vbz) calculada utilizando la Ecuación 6-1.
c. Sistemas con cierre intermitente de la entrada de aire exterior: la toma de aire exterior
promedio sobre el tiempo (T) será no menor que la entrada de aire exterior mínima (Vot)
calculada utilizando la Ecuación 6-3, 6-4 ó 6-8 como sea apropiado.
Ventilación
6.2.6 Diseño para Variar las Condiciones de Operación.
6.2.6.1 Condiciones de Carga Variables. Los sistemas de ventilación deben diseñarse para
ser capaces de proveer no menos de las mínimas tasas de ventilación requeridas en la zona de
respiración cuando las zonas servidas por el sistema están ocupadas, incluyendo todas las condiciones de carga total y parcial.
Nota: El flujo de entrada de aire exterior mínimo puede ser menos que el valor de diseño en
condiciones de carga parcial.
6.2.6.2 Condiciones de Corto Plazo. Si es conocido que el pico de ocupación será de duración corta y/o la ventilación será variada o interrumpida por un corto período de tiempo, el diseño
será basado en las condiciones de promedio sobre un período de tiempo (T) determinado por la
Ecuación 6-9a utilizando unidades I-P (Ecuación 6-9b utilizando unidades SI).
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 6-3
Max (ZP)
0.15
0.25
0.35
0.45
0.55
>0.55
6.3.4.2 Evaluación Subjetiva. Utilizando una evaluación subjetiva del ocupante conducida en el
edificio terminado, determinar las tasas de corriente de aire exterior mínimas requeridas para obtener el
nivel de aceptabilidad especificado en la Sección 6.3.3 dentro de cada zona servida por el sistema.
Notas:
a. El Apéndice B presenta un acercamiento a la evaluación subjetiva del ocupante.
320
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
6.2.7.1.1 La Ventilación de Control de la Demanda (DCV) será permitido como un medio
opcional de reposición dinámica.
Excepción: CO2-ventilación de control de la demanda (DCV) no será aplicada en zonas con fuentes internas de CO2 aparte de los ocupantes o con mecanismos de remoción de CO2, como limpiadores de aire gaseoso.
6.2.7.1.2 La corriente de aire de la zona de respiración (Vbz) será restablecida en respuesta a
la ocupación actual y será no menor que los componentes del edificio (Ra Az) de la zona de Ventilación de Control de la Demanda (DVC).
Nota: Ejemplos de métodos de reposición o dispositivos incluye contadores de población, sensores de dióxido de carbono (CO2), temporizadores, horarios de ocupación o sensores de ocupación.
6.2.7.1.3 El sistema de ventilación será controlado tales como el estado de equilibrio que proporciona a cada zona con no menos de la corriente de aire exterior de la zona de respiración (Vbz)
para la población actual de la zona.
6.2.7.1.4 Cuando el sistema mecánico del aire acondicionado es deshumidificador, el flujo de
entrada de aire exterior total actual para el edificio no será menor a la corriente de aire de escape
total coincidente.
6.2.7.1.5 Documentación. Una descripción escrita del equipo, métodos, secuencias de control,
puntos de ajuste y las funciones operativas destinadas serán proporcionadas. Una tabla será proporcionada que muestre la corriente de aire de entrada exterior mínima y máxima para cada sistema.
6.2.7.2 Eficacia de Ventilación. Variaciones en la eficacia con la cual el aire exterior es distribuido a los ocupantes bajo diferentes corrientes de aire del sistema de ventilación y temperaturas será permitido como una base opcional de restitución dinámica.
6.2.7.3 Fracción de Aire Exterior. Una fracción mayor del aire exterior en el suministro de
aire debido a la entrada de aire exterior adicional para el enfriamiento libre o reposición de aire de
escape será permitido como una base opcional de restauración dinámica.
6.3 Procedimiento de la Calidad de Aire Interior (IAQ). La corriente de aire exterior de la
zona de respiración (Vbz) y/o sistema de flujo de entrada de aire exterior (Vot) será determinado de
acuerdo con las Secciones 6.3.1 al 6.3.5.
6.3.1 Fuentes Contaminantes. Los contaminantes o mezclas de preocupación para
propósitos de diseño serán identificados. Para cada contaminante o mezcla de preocupación, fuentes internas (ocupantes y materiales) y fuentes exteriores serán identificadas y la tasa de emisión
para cada contaminante de preocupación de cada fuente será determinada.
Nota: El Apéndice B enumera información para algunos contaminantes potenciales de
preocupación.
6.3.2 Concentración de Contaminantes. Para cada contaminante de preocupación, un límite
de concentración y su correspondiente período de exposición y una referencia apropiada a una
autoridad competente se especificará.
Nota: El Apéndice B incluye pautas de concentración para algunos contaminantes potenciales de preocupación.
6.3.3 Calidad de Aire Interior Percibida. El nivel de diseño de aceptabilidad de aire interior
se especificará en términos del porcentaje de los ocupantes del edificio y/o visitantes que expresan
satisfacción con la calidad de aire interior (IAQ) percibida.
6.3.4 Enfoque de Diseño. Las tasas de corriente de aire exterior del sistema y zona serán
mayores de aquellas determinadas de acuerdo con la Sección 6.3.4.1 y cualquiera 6.3.4.2 ó
6.3.4.3, basada en tasas de emisión, límites de concentración y otros parámetros de diseño relevantes (e., eficacias en limpieza de aire y suministro de tasas de corriente de aire).
6.3.4.1 Análisis de Balance de Masa. Utilizando un análisis de balance de masa dinámico o
estado estable, determinar las tasas de corriente de aire exterior mínimas requeridas para lograr los
límites de concentración especificadas en la Sección 6.3.2 para cada contaminante o mezcla de
preocupación dentro de cada zona servida por el sistema.
Notas:
a. El Apéndice D incluye ecuaciones de balance de masa y estado estable que describen el
impacto de la limpieza de aire y tasas de recirculación para sistemas de ventilación que
sirven a una zona.
b. En el edificio terminado, medida de la concentración de contaminantes o mezclas de
preocupación pueden ser útiles como un medio de comprobar la exactitud del análisis de
diseño del balance de masa, pero tal medida no es requerida para cumplimiento.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Ventilación
13.fm Page 320 Thursday, March 3, 2016 2:04 PM
13.fm Page 321 Thursday, March 3, 2016 2:04 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
321
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Ventilación
6.3.4.3 Zona Similar. Las tasas de corriente de aire exterior mínimas serán no menores que aquellas encontradas de acuerdo con la Sección 6.3.4.2 para una zona sustancialmente similar (ej. en una
zona con contaminantes de preocupación idénticos, límites de concentración, eficacia de limpieza de
aire y nivel de aceptabilidad especificado; y con tasas de emisión y fuentes contaminantes similares).
6.3.5 Procedimiento Combinado de Calidad de Aire Interior (IAQ) y Procedimiento de Tasa
de Ventilación. El Procedimiento de la Calidad de Aire Interior (IAQ) en conjunción con el Procedimiento de la Tasa de Ventilación puede ser aplicado a una zona o sistema. En este caso, el Procedimiento de la Tasa de Ventilación debe utilizarse para determinar la corriente de aire exterior mínima de
la zona requerida y el Procedimiento de la Calidad de Aire Interior (IAQ) será utilizada para determinar
el aire exterior adicional o limpieza de aire necesaria para obtener los límites de concentración de los
contaminantes de preocupación.
Nota: La mejora de la calidad de aire interior a través del uso de limpieza de aire o provisión de
aire exterior adicional en conjunto con tasas de ventilación mínimas pueden ser cuantificados utilizando el procedimiento de calidad de aire interior (IAQ).
6.3.6 Documentación. Cuando el procedimiento de la calidad de aire interior (IAQ) es utilizado,
la siguiente información será incluida en la documentación de diseño: los contaminantes de preocupación considerados en el proceso de diseño, las fuentes y tasas de emisión de los contaminantes de
preocupación, los límites de concentración y los períodos de exposición y las referencias para estos
límites y el acercamiento analítico utilizado para determinar las tasas de ventilación y requisitos de
limpieza de aire. El monitoreo de contaminantes y ocupante y/o planes de evaluación del visitante también deberán ser incluidos en la documentación.
6.4 Procedimiento de Ventilación Natural. Los sistemas de ventilación natural deben ser diseñados de acuerdo con esta sección e incluirán sistemas de ventilación mecánica de acuerdo con la Sección
6.2 y(o Sección 6.3.
Excepción:
a. Una ingeniería de sistema de ventilación natural, cuando es aprobada por la autoridad que
tiene jurisdicción, no necesita reunir los requisitos de la Sección 6.4
b. Los sistemas de ventilación mecánica no son necesarios cuando:
1. Las aberturas de ventilación natural que cumplan con los requisitos de la Sección 6.4
están permanentemente abiertas o tienen controles que previenen a las aberturas ser cerradas durante períodos de ocupación esperada, o
2. La zona no es servida por equipo de calefacción o enfriamiento.
6.4.1 Área de Piso a ser Ventilada. Espacios o porciones de espacio, a ser naturalmente ventiladas deben estar situadas dentro de una distancia basada en la altura del techo, como determinado por
las Secciones 6.4.1.1, 6.4.1.2 ó 6.4.1.3, de las aberturas de pared operables que reúnan los requisitos de
la Sección 6.4.2. Para espacios con techos que no están paralelos al piso, la altura del techo será determinada de acuerdo con la Sección 6.4.1.4.
6.4.1.1 Abertura Lateral Única. Para espacios con aberturas operables en un lado del espacio, la
distancia máxima desde las aberturas operables es 2H, donde H es la altura del techo.
6.4.1.2 Abertura Lateral Doble. Para espacios con aberturas operables en dos lados opuestos del
espacio, la distancia máxima de las aberturas operables es 5H, donde H es la altura del techo.
6.4.1.3 Aberturas de las Esquinas. Para espacios con aberturas operables en dos lados adyacentes de un espacio (ej. dos lados de una esquina), la distancia máxima de las aberturas operables es
5H a lo largo de una línea trazada entre las dos aberturas que están más alejados. El área del piso fuera
de esa línea debe cumplir con la Sección 6.4.1.1.
6.4.1.4 Altura del techo. La altura del techo, H, a ser utilizado en las secciones 6.4.1.1 al 6.4.1.3
será la altura del techo mínima en el espacio.
Excepción: Para techos que están aumentando en altura a medida que aumenta la distancia desde las
aberturas, la altura del techo será determinada como la altura promedio del techo dentro de 20 pie (6 m)
de las aberturas operables.
6.4.2 Ubicación y Tamaño de las Aberturas. Espacios, o porciones de espacios, a ser ventilados
naturalmente estarán permanentemente abiertos a paredes operables abiertas directamente al aire libre,
el área que se puede abrir de la cual es un mínimo del 4% del área neta del piso ocupable. Donde las
aberturas están cubiertas con persianas o de, otro modo obstruido, el área que se puede abrir estará
basada en la zona neta libre sin obstáculos a través de las aberturas. Donde las habitaciones interiores, o
porciones de habitaciones, sin aberturas directas al aire libre son ventiladas a través de habitaciones
adjuntas, la abertura entre habitaciones debe estar permanentemente sin obstrucción y tener un área
libre de no menos que el 8% del área de la habitación interior no menos que 25 píe2 (2.3 m2).
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
b. El nivel de aceptabilidad a menudo aumenta en respuesta a las tasas de corriente de aire exterior incrementadas, nivel incrementado de los depuradores de aire interior y/o exterior o tasa
de emisión contaminante interior y/o exterior disminuida.
13.fm Page 322 Thursday, March 3, 2016 2:04 PM
Tabla 6-4 Tasas de Escape Mínimas
Ventilación
Categoría de Ocupación
Tasa de Escape,
cfm (L/s)/unidad
—
—
—
—
—
—
—
—
—
Tasa de Escape,
cfm/pie2 (L/s·m2)
0.50 (—)
0.70 (3.5)
1.50 (7.5)
0.50 (2.5)
0.60 (3.0)
1.00 (5.0)
0.50 (2.5)
1.00 (5.0)
1.00 (5.0)
Notas
B
A
Clase de
Aire
1
2
2
2
2
2
2
2
2
—
1.00 (5.0)
3
—
—
—
—
—
—
—
—
50/100 (25/50)
—
—
25/50 (12.5/25)
50/70 (25/35)
—
0.30 (1.5)
0.70 (3.5)
0.25 (1.25)
0.50 (2.5)
—
0.75 (3.7)
0.90 (4.5)
—
—
1.00 (5.0)
1.50 (7.5)
—
—
0.50 (2.5)
2
2
2
2
4
2
2
3
2
3
4
2
2
2
F
C
F
G
F
F
E
D
A Se mantienen donde los motores están en marcha, deben tener un sistema de escape que directamente conecte al escape
del motor y prevenir escape de humos.
B Cuando el equipo de combustión está destinado ser utilizado en la superficie de juego, ventilación de dilución adicional
y/o control de fuente será proporcionado.
C Escape no es requerido si dos o más lados comprenden paredes que están por lo menos 50% abiertas al exterior.
D La tarifa es para inodoro y/o urinario. Proporcione la tarifa más alta cuando los períodos de uso intensivo se espera que
ocurra, ej. inodoros en teatros, escuelas e instalaciones deportivas. La tarifa más alta podrá utilizarse.
E La tarifa es para una sala de baño destinada a ser ocupada por una persona a la vez. Para la operación continua del
sistema durante horas normales de uso, la tarifa más baja puede ser utilizada. De otra manera utilice la tarifa más alta.
F Ver otras normas aplicables para tasa de escape.
G Para operación continua del sistema, la tasa más baja puede ser utilizada. De otra manera utilice la tasa más alta.
322
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Arenas
Aulas de Arte
Salas de reparación de automóviles
Barberías
Salones de Belleza y Uñas
Células con inodoros
Copia, salas de impresión
Cuartos oscuros
Laboratorios educativos de ciencia
Armarios de conserje, cuartos de basura,
reciclaje
Cocinas pequeñas
Cocinas – comercial
Armario/vestuarios
Cuartos de armarios
Cabinas de pinturas
Estacionamientos
Tiendas de animales (zonas de animales)
Cuartos de maquinarias de refrigeración
Cocinas residenciales
Almacenaje de ropa socia
Cuartos de almacenaje, químicos
Inodoros – privado
Inodoros – públicos
Talleres de madera/Aulas
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
6.4.3 Control y Accesibilidad. Los medios para abrir las aberturas operables requeridas
deben estar fácilmente accesibles a los ocupantes del edificio siempre que el espacio esté ocupado. Los controles serán diseñados para coordinar apropiadamente la operación de los sistemas
de ventilación natural y mecánico.
6.5 Ventilación de Escape. El diseño de la corriente de aire de escape será determinado de
acuerdo con los requisitos en la Tabla 6-4. Aire de reposición de escape puede ser cualquier combinación de aire exterior, aire recirculado y aire de transferencia.
6.6 Procedimientos de Documentación de Diseño. Criterios de diseño y supuestos serán
documentados y deberán estar disponibles para operación del sistema dentro de un tiempo razonable después de la instalación. Ver Secciones 4.3, 5.1.3, 5.16.4, 6.2.7.1.5 y 6.3.6 con relación a
supuestos que deben ser detallados en la documentación.
13.fm Page 323 Thursday, March 3, 2016 2:04 PM
Este apéndice presenta un procedimiento alternativo para calcular la eficiencia de ventilación
del sistema (Ev) que debe utilizarse cuando los valores de la Tabla 6-3 no son usados. En este procedimiento alternativo, Ev es igual al valor más bajo calculado de la zona de eficiencia de ventilación (Evz) (ver la Ecuación A-8 abajo). La Figura A-1 contiene una esquemática del sistema de
ventilación que representa la mayoría de las cantidades utilizadas en este apéndice.
A1. EFICIENCIA DE LA VENTILACION DEL SISTEMA
Para cualquier sistema de recirculación de zona múltiple, la eficiencia de ventilación del
sistema (Ev) será calculada de acuerdo con las Secciones A1.1 a la A1.3.
A1.1 Fracción de Aire Exterior Promedio. La fracción de aire exterior promedio (Xs) para
el sistema de ventilación será determinada de acuerdo con la Ecuación A-1.
Xs = Vou/Vps
(A-1)
323
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura A.1 Esquemática de Sistema de Ventilación
Ventilación
donde la toma de aire exterior incorrecta (Vou) se encuentra de acuerdo con la Sección 6.2.5.3 y la
corriente de aire primaria del sistema (Vps) es encontrada en la condición analizada.
Nota: Para propósitos de diseños del sistema de volumen de aire variable (VAV), Vps es la
corriente de aire primario más alta esperada del sistema en el diseño de la condición analizada. La
corriente de aire primario del sistema en el diseño es usualmente menor que la suma de los valores
de corriente de aire primario de la zona de diseño, debido a que la corriente de aire primario rara
vez se eleva simultáneamente en todas las zonas del volumen de aire variable (VAV).
A1.1 Eficacia de Ventilación de la Zona. La eficacia de ventilación de la zona (Evz), ej., la
eficiencia con la cual un sistema distribuye aire exterior desde la toma a una zona de respiración
individual, será determinada de acuerdo con la Sección A1.2.1 ó A1.2.2.
A1.2.1 Sistemas de Suministro Único. Para sistemas de “suministro único”, en donde todo
el aire suministrado a cada zona de ventilación es una mezcla de aire exterior y nivel de sistema de
aire recirculado, eficiencia de ventilación de la zona (Evz) será determinado de acuerdo con la
Ecuación A-2. Ejemplos de sistemas de suministro único incluye recalentamiento de volumen
constante, volumen de aire variable (VAV) de ducto único, ventilador único doble conducto y
sistemas de zona múltiple.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
INFORMATIVO APÉNDICE A—SISTEMAS DE ZONA MÚLTIPLE
13.fm Page 324 Thursday, March 3, 2016 2:04 PM
(A-2)
Evz = (Fa + Xs · Fb – Zpz · Ep · Fc)/Fa
(A-3)
Ventilación
donde las fracciones de aire del sistema Fa, Fb, y Fc son determinadas de acuerdo con la Ecuación
A-4, A-5, y A-6, respectivamente.
Fa = Ep + (1 – Ep) · Er
(A-4)
Fb = Ep
(A-5)
Fc = 1 – (1 – Ez) · (1 – Er) · (1 – Ep)
(A-6)
donde la fracción de aire primario de la zona (Ep) es determinada de acuerdo con la Ecuación A-7;
la fracción de recirculación secundaria de la zona (Er) es determinado por el diseñador basado en
la configuración del sistema; y la eficacia de distribución de aire de la zona (Ez) es determinado de
acuerdo con la Sección 6.2.2.2.
Nota: Para sistemas de retorno de pleno con recirculación secundaria (ej., ventilador accionado AV con retorno de pleno) Er es usualmente menos de 1,0, aunque los valores pueden variar
desde 0.1 a 1.2 dependiendo de la ubicación de la zona de ventilación relativa a otras zonas y el
transportador de aire. Para sistemas de retorno por conducto con recirculación secundaria (ej.,
ventilador accionado, volumen de aire variable VAV con retorno por conducto), Er es típicamente
0.0, mientras que para aquellos con nivel de sistema de recirculación (ej., sistemas de ventilador
doble conducto doble con retorno de conducto) Er es típicamente 1.0. Para otros tipos de sistemas,
Er es típicamente 0.75.
Ep = Vpz/Vdz
(A-7)
Ev = mínimo (Evz)
(A-8)
A4. CALCULOS ALTERNATIVOS
Ecuaciones de masa o balance de flujo para sistemas de zona múltiple pueden utilizarse para
determinar la eficiencia de ventilación del sistema y otros parámetros de diseño, siempre que ellos
resulten en la toma de aire exterior (Vot) que está dentro del 5% del valor de la corriente de aire
obtenido utilizando la eficiencia de ventilación del sistema (Ev) calculado utilizando la Ecuación
A-8 o que representan con más precisión una configuración particular del sistema.
A4. PROCESO DE DISEÑO
La eficiencia de ventilación del sistema y por consiguiente el flujo de toma de aire exterior
para el sistema (Vot) determinado como parte del proceso de diseño están basados en el diseño y
flujos de aire mínimos suministrados a zonas de ventilación así como el diseño de los requisitos
de aire exterior a las zonas. Para los propósitos de diseño del sistema de volumen de aire variable
(VAV), la eficiencia de ventilación de la zona (Evz) para cada zona de ventilación se encontrará
utilizando la corriente de aire primario de la zona mínima esperada (Vpz) y utilizando la corriente
de aire primaria del sistema más alto esperado (V ps) en la condición de diseño analizada.
Nota: Incrementando los valores de flujo de aire suministrados a la zona durante el proceso
de diseño, particularmente a las zonas críticas que requieren la fracción más alta del aire exterior,
reduce el requisito de flujo de toma de aire exterior del sistema determinado en el cálculo.
324
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
donde Vdz es la corriente de aire de descarga de la zona
Nota: Para zona única y sistemas de suministro único, Ep es 1.0.
A1.3 Eficiencia de la Ventilación del Sistema. La eficiencia de la ventilación del sistema
igualará la eficiencia de ventilación de la zona más baja entre todas las zonas de ventilación servidas por el transportador de aire, de acuerdo con la Ecuación A.8.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Evz = 1 + Xs – Zpz
donde la fracción de aire exterior promedio (Xs) para el sistema es determinado de acuerdo con la
Ecuación A-1 y la fracción de aire exterior primario (Zpz), para la zona es determinado de acuerdo
con la Sección 6.2.5.1.
A1.2.2 Sistemas de Recirculación Secundaria. Para sistemas de “recirculación secundaria”
en donde todo o parte del aire de suministro a cada zona de ventilación es aire recirculado (que no
ha sido directamente mezclado con aire exterior) de otras zonas, la eficiencia de ventilación de la
zona (Evz) será determinada de acuerdo con la Ecuación A-3. Ejemplos de sistemas de recirculación secundaria incluyen sistemas de ventilador doble, ducto doble y ventilador accionado caja
de mezcla, y sistemas que incluyen ventiladores de transferencia para salas de conferencia.
13.fm Page 325 Thursday, March 3, 2016 2:04 PM
Ejemplo: En edificios de oficina, generalmente solo es necesario calcular Evz para una zona de
ventilación interior típica, debido a que los parámetros indicados arriba son generalmente iguales
para todos los espacios interiores. Si el aire de suministro aéreo es utilizado para calentar el
perímetro, generalmente también es necesario calcular Evz para la zona perimetral con el primario
esperado más bajo o la tasa de corriente de aire de descarga por área de unidad. No otros cálculos
para Evz son típicamente necesarios, aún si el edificio tiene 1000 zonas de ventilación, proporcionando la ventilación Excepción: para cualquier sala de conferencias o no ocupación de oficina
Excepción: las zonas están calculadas separadamente.
A4. SIMBOLOS
Az
Ep
Er
Evz
Ez
Fa
Fb
Fc
Ps
Pz
Ra
Rp
Vbz
325
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Ev
Ventilación
D
= Área del Piso de Zona: El área neta del piso ocupable de la zona de ventilación pie2
(m2).
= Diversidad de Ocupantes: La proporción de la población del sistema a la suma de las
poblaciones de la zona.
= Fracción de Aire Primario: La fracción de aire primario en el aire de descarga a la zona
de ventilación.
= Fracción de Recirculación Secundario: En sistemas con recirculación secundaria de
aire de retorno, la fracción de aire recirculado secundario a la zona que es representativa
del promedio de aire de retorno del sistema antes que aire directamente recirculado de la
zona.
= Eficiencia de Ventilación del Sistema: La eficiencia con la cual el sistema distribuye
aire desde la toma de aire exterior a la zona de respiración en la zona crítica de ventilación, el cual requiere la fracción más grande de aire exterior en la corriente de aire primaria. Nota: Ev puede ser determinada de acuerdo con la Sección 6.2.5.2 o la Sección A1.
= Eficiencia de Ventilación de la Zona: La eficiencia con la cual el sistema distribuye aire
desde la toma de aire exterior a la zona de respiración en cualquier zona de ventilación
particular.
= Eficacia de Distribución de Aire de la Zona: Una medida de la eficacia de la distribución de aire de suministro a la zona de respiración. Nota: Ez es determinado de acuerdo
con la Sección 6.2.2.2
= Fracción de Aire de Suministro: La fracción de aire de suministro a la zona de ventilación que incluye fuentes de aire desde fuera de la zona.
= Fracción de Aire Mixto: La fracción de aire de suministro a la zona de ventilación de
aire primario completamente mezclado.
= Fracción de Aire Exterior: La fracción de aire exterior a la zona de ventilación que
incluye fuentes de aire desde fuera de la zona.
= Población del Sistema: El número simultáneo de ocupantes en el área servida por el
sistema de ventilación.
= Población de la Zona: Ver Sección 6.2.2.1.
= Tasa de Aire Exterior del Área: Ver Sección 6.2.2.1.
= Tasa de Aire Exterior de la Gente: Ver Sección 6.2.2.1.
= Corriente de Aire Exterior de la Zona de Respiración: Ver Sección 6.2.2.1.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
A3.1 Seleccionando las Zonas para Cálculo. La eficiencia de ventilación de la zona (Evz) será
calculada para todas las zonas de ventilación.
Excepción: Debido a que la eficiencia de ventilación del sistema (Ev) es determinada por el valor
mínimo de la eficiencia de ventilación de la zona (Evz), de acuerdo con la Ecuación A-8, el cálculo
de Evz no es requerido para ninguna zona de ventilación que tiene un valor Evz que es igual o más
grande que el de la zona de ventilación para el cual un cálculo ha sido hecho.
Nota: El valor de Evz para una zona de ventilación será igual a o más grande que para otra
zona de ventilación si todos los siguientes son verdaderos relativo a la otra zona de ventilación:
a. Área de piso por ocupante (Az/Pz) no es menor
b. La tasa mínima de corriente de aire de descarga de la zona por área de unidad (Vdz/Az) no
es menor
c. La fracción de aire primario (Ep) no es menor
d. La eficacia de distribución del aire de la zona (Ez) no es menor
e. La tasa de aire exterior del área (Ra) no es mayor
f. La tasa de aire exterior de gente (Rp) no es mayor
13.fm Page 326 Thursday, March 3, 2016 2:04 PM
Ventilación
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
326
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Vdz = Corriente de Aire de Descarga de la Zona: La corriente de aire (suministro) de descarga esperada a la zona que incluye corriente de aire primario y corriente de aire recirculado secundario, cfm (L/s).
Vot = Flujo de Toma de Aire Exterior: Ver Secciones 6.2.3, 6.2.4. 6.2.5.4.
Vou = Toma de Aire Exterior Incorrecto: Ver Sección 6.2.5.3.
Voz = Corriente de Aire Exterior de la Zona: Ver Sección 6.2.2.3.
Vps = Corriente de Aire Primario del Sistema: La corriente de aire primario total suministrada a todas las zonas servidas por el sistema de la unidad de tratamiento de aire en el
cual la toma de aire exterior está situada.
Vpz = Corriente de Aire Primario de la Zona: Ver Sección 6.2.5.1.
Xs = Fracción de Aire Exterior Promedio: En el transportador de aire primario, la fracción
del flujo de toma de aire exterior en la corriente de aire primario del sistema.
Zpz = Fracción de Aire Exterior Primario: La fracción de aire exterior requerida en el aire
primario suministrado a la zona de ventilación antes de la introducción de cualquier recirculación secundaria aireó la ventilación para cualquier cuarto de conferencias o zonas de
ocupación fuera de oficina se calculan por separado.
13.fm Page 327 Thursday, March 3, 2016 2:04 PM
Función de Espacio
Relación de
TodoelEscape
Aire de
Temp.
Presión a
Ach
Ach
de Aire de
Recirculación
RH (k), Diseño
Zonas
Mínimo Mínimo Habitación
por Medio de
%
(l),
Adyacentes Exterior Total Directamente Unidades de
°F (°C)
(n)
al Exterior (j) Habitación (a)
Cirugía y Cuidado Crítico
Quirófanos Clases B y C, (m),
(n), (o)
Positivo
4
20
N/R
No
30–60
68–75
(20–24)
Operativo/salas citoscópicas
quirúrgicas, (m), (n) (o)
Positivo
4
20
N/R
No
30–60
68–75
(20–24)
Salas de parto (Cesárea) (m),
(n), (o)
Positivo
4
20
N/R
No
30–60
68–75
(20–24)
Área de servicio sub-estéril
N/R
2
6
N/R
No
N/R
N/R
Sala de recuperación
N/R
2
6
N/R
No
30–60
70–75
(21–24)
Cuidado intensivo y crítico
Positivo
2
6
N/R
No
30–60
70–75
(21–24)
Cuidado intensivo de heridas
(unidad de quemados)
Positivo
2
6
N/R
No
40–60
70–75
(21–24)
Cuidado intensivo de recién
nacidos
Positivo
2
6
N/R
No
30–60
70–75
(21–24)
2
6
N/R
N/R
30–60
70–75
(21–24)
Positivo
3
15
N/R
No
30–60
70–75
(21–24)
Médico/anestesia almacenaje
de gas (r)
Negativo
N/R
8
Si
N/R
N/R
N/R
Positivo
3
15
N/R
No
30–60
Salas de espera ER (q)
Negativo
2
100000
Si
N/R
max 65
70–75
(21–24)
Triage
Negativo
2
12
Si
N/R
max 60
70–75
(21–24)
Descontaminación ER
Negativo
2
12
Si
No
N/R
N/R
Salas de espera radiología (q)
Negativo
2
12
Si
N/R
max 60
70–75
(21–24)
Operativo Clase A/Salas de
Procedimiento (o), (d)
Positivo
3
15
N/R
No
30–60
70–75
(21–24)
70–75
(21–24)
Enfermería de hospitalización
Cuarto de paciente (s)
N/R
2
6
N/R
N/R
max 60
Negativo
N/R
10
Si
No
N/R
N/R
Suite de sala de recién nacido
N/R
2
6
N/R
No
30–60
72–78
(22–26)
Sala de protección de medio
ambiente (f), (n), (t)
Positivo
2
12
N/R
No
max 60
70–75
(21–24)
Sala II (e), (n), (u)
Negativo
2
12
Si
No
max 60
70–75
(21–24)
N/R
N/R
10
Si
No
N/R
N/R
Cuarto de baño
Antesala de aislamiento AII (t)
(u)
Labor/parto/recuperación/post
parto (LDRP) (s)
N/R
2
6
N/R
N/R
70–75
max 60
(21–24)
Labor/parto/
recuperación(LDR) (s)
N/R
2
6
N/R
N/R
max 60
70–75
(21–24)
Corredor
N/R
N/R
2
N/R
N/R
N/R
N/R
327
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Sala ocular con láser
70–75
(21–24)
Ventilación
N/R
Sala de trauma (crisis o choque)
(c)
Sala de Tratamiento (p)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 13.6 Parámetros de Diseño de Ventilación para Centros de Salud
[Std 170-2008, Tbl 7-1]
13.fm Page 328 Thursday, March 3, 2016 2:04 PM
Función de Espacio
Relación de
TodoelEscape
Aire de
Temp.
Presión a
Ach
Ach
de Aire de
Recirculación
RH (k), Diseño
Zonas
Mínimo Mínimo Habitación
por Medio de
%
(l),
Adyacentes Exterior Total Directamente Unidades de
°F (°C)
(n)
al Exterior (j) Habitación (a)
Centro de Enfermería Especializada
Sala de residentes
N/R
2
2
N/R
N/R
N/R
70–75
(21–24)
Reunión de residentes/
actividad/comida
N/R
4
4
N/R
N/R
N/R
70–75
(21–24)
Negativo
2
6
N/R
N/R
N/R
70–75
(21–24)
N/R
2
6
N/R
N/R
N/R
70–75
(21–24)
Negativo
N/R
10
Si
N/R
N/R
70–75
(21–24)
Terapia física
Terapia ocupacional
Cuarto de baño
Radiología (v)
Rayos-X (diagnóstico y
tratamiento)
2
6
N/R
N/R
max 60
72–78
(22–26)
Positivo
3
15
N/R
No
max 60
70–75
(21–24)
Cuarto negro (g)
Negativo
2
10
Si
No
N/R
N/R
Broncoscopio, colecta de
esputo y administración de
pentamidina (n)
Negativo
2
12
Si
No
N/R
68–73
(20–23)
Laboratorio, general (v)
Negativo
2
6
N/R
No
N/R
70–75
(21–24)
Laboratorio, bacteriología (v)
Negativo
2
6
Si
No
N/R
70–75
(21–24)
Laboratorio, bioquímica (v)
Negativo
2
6
Si
No
N/R
70–75
(21–24)
Laboratorio, citología (v)
Negativo
2
6
Si
No
N/R
70–75
(21–24)
Laboratorio, lavar vidrios
Negativo
2
10
Si
No
N/R
N/R
Laboratorio, histología (v)
Negativo
2
6
Si
No
N/R
70–75
(21–24)
Laboratorio, microbiología (v)
Negativo
2
6
Si
No
N/R
70–75
(21–24)
Laboratorio, medicina nuclear
(v)
Negativo
2
6
So
No
N/R
70–75
(21–24)
Laboratorio, patología (v)
Negativo
2
6
Si
No
N/R
70–75
(21–24)
Laboratorio, serología (v)
Negativo
2
6
Si
No
N/R
70–75
(21–24)
Laboratorio, esterilizante
Negativo
2
10
Si
No
N/R
70–75
(21–24)
Laboratorio, transferencia de
medios (v)
Positivo
2
4
N/R
No
N/R
70–75
(21–24)
Sala de autopsia (n)
Negativo
2
12
Si
No
N/R
68–75
(20–24
Cuerpo no refrigerado-cuarto
de conservación (h)
Negativo
N/R
10
Si
No
N/R
70–75
(21–24)
Farmacia (b)
Positivo
2
4
N/R
N/R
N/R
N/R
Ventilación
Diagnóstico y Tratamiento
328
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
N/R
Rayos-X
Rayos-X (cirugía/cuidado
crítico y cateterismo)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 13.6 Parámetros de Diseño de Ventilación para Centros de Salud (Continuo)
[Std 170-2008, Tbl 7-1]
13.fm Page 329 Thursday, March 3, 2016 2:04 PM
Función de Espacio
Relación de
TodoelEscape
Aire de
Temp.
Presión a
Ach
Ach
de Aire de
Recirculación
RH (k), Diseño
Zonas
Mínimo Mínimo Habitación
por Medio de
%
(l),
Adyacentes Exterior Total Directamente Unidades de
°F (°C)
(n)
al Exterior (j) Habitación (a)
N/R
2
6
N/R
N/R
max 60
70–75
(21–24)
Sala de medicación
Positivo
2
4
N/R
N/R
max 60
70–75
(21–24)
Endoscopía
Positivo
2
15
N/R
No
30-60
68–73
(20–23)
Limpieza de endoscopio
Negativo
2
10
Si
No
N/R
N/R
N/R
2
6
N/R
N/R
max 60
70–75
(21–24)
Hidroterapia
Negativo
2
6
N/R
N/R
N/R
72–78
(22–26)
Terapia física
Negativo
2
6
N/R
N/R
Max 65
72–78
(22–26)
Negativo
N/R
10
Si
No
N/R
N/R
Sala de examen
Cuarto de tratamiento
Esterilización
Cuarto de equipo esterilizador
Centro Médico y Suministro Quirúrgico
Negativo
2
6
Si
No
N/R
72–78
(22–26)
Cuarto de trabajo de limpieza
Positivo
2
4
N/R
No
max 60
72–78
(22–26)
Almacenaje estéril
Positivo
2
4
N/R
N/R
max 60
72–78
(22–26)
72–78
(22–26)
Servicio
Centro de preparación de
comida (i)
2
10
N/R
No
N/R
Negativo
N/R
10
Si
No
N/R
N/R
Almacenaje de dietas
N/R
N/R
2
N/R
No
N/R
72–78
(22–26)
Lavandería, general
Negativo
2
10
Si
No
N/R
N/R
Lencerías sucias clasificación y
almacenaje
Negativo
N/R
10
Si
No
N/R
N/R
Almacenaje lencerías limpias
Positivo
N/R
2
N/R
N/R
N/R
72–78
(22–26)
Lencería y cuarto de verter
basura
Negativo
N/R
10S
Si
No
N/R
N/R
Cuarto de urinarios
Negativo
N/R
10
Si
No
N/R
N/R
Cuarto de baño
Negativo
N/R
10
Si
No
N/R
72–78
(22–26)
Armario del conserje
Negativo
N/R
10
Si
No
N/R
N/R
10
Si
No
N/R
N/R
Espacio de Apoyo
Cuarto de trabajo desperdicios
o tenencia de basura
Negativo
2
Cuarto de trabajo limpieza o
tenencia limpieza
Positivo
2
4
N/R
N/R
N/R
N/R
Almacenaje de material
peligroso
Negativo
2
10
Si
No
N/R
N/R
Nota: N/R = ningún requisito
329
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
N/R
Lavado de cerámica
Ventilación
Sucio o cuarto de
descontaminación
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 13.6 Parámetros de Diseño de Ventilación para Centros de Salud (Continuo)
[Std 170-2008, Tbl 7-1]
13.fm Page 330 Thursday, March 3, 2016 2:04 PM
Proveer un manual O&M junto con planos de diseño del sistema final, actualizados y mantenidos en el sitio.
Tabla 13.7
Actividad de Mantenimiento Mínimo y Frecuencia
Item
Ventilación
Filtros y dispositivos de limpieza
de aire
Amortiguadores de aire exterior
y Actuadores
Código de
Actividad
A
B
Humidificadores
C
Bobinas de deshumidificación
D
Bandejas de drenaje y otras
superficies adyacentes sujetas a
humectación
Rejillas de admisión de aire
exterior, pantallas de aves,
eliminadores de vapor y áreas
adyacentes
Frecuencia Mínimaa
De acuerdo al Manual O&M
Cada tres meses o de acuerdo con el Manual
O&M
Cada tres meses de uso o de acuerdo con el
Manual O&M
Regularmente cuando es probable que
deshumidifaciones ocurran pero no menos que
uno por año o como especificado en el Manual
O&M
Uno por año durante la estación fría o como
especificado en el Manual O&M
E
Cada seis meses o como especificado en el
Manual O&M
Sensores utilizados para control
de aire exterior mínimo dinámico
F
Cada seis meses o periódicamente de acuerdo
con el Manual O&M
Sistemas de tratamiento de aire
excepto para unidades bajo
2000 cfm (1000 L/s)
G
Una vez cada cinco años
Torres de enfriamiento
H
De acuerdo con el Manual O&M o el proveedor
del sistema de tratamiento
I
Periódicamente de acuerdo con el Manual
O&M
Desagües de piso situados en
cámaras o cuartos que sirven
como cámaras de aire
Equipo/ acceso a los
componentes
Contaminación microbiana
visible
Intrusión de agua o acumulación
J
K
K
Código de Actividad:
A Mantener de acuerdo al Manual O&M.
B Inspeccionar visualmente o monitorear para función apropiada.
C Limpiar y mantener en límite de ensuciamiento y crecimiento microbiano.
D Inspeccionar visualmente para limpieza y crecimiento microbiano y limpiar cuando la suciedad es observada.
E Inspeccionar visualmente para limpieza e integridad y limpiar cuando es necesario.
F Verificar precisión y recalibrar o reemplazar como sea necesario.
G Medir cantidad mínima de aire exterior. Si las tasas de flujo de aire mínimas medidas son menos del 90% de la tasa
de aire exterior mínima en el Manual O&M, ellas serán ajustadas o modificadas para traerlas arriba del 90% serán
evaluadas para determinar si las tasas medidas están en conformidad con esta norma.
H Trate de limitar el crecimiento de contaminantes microbiológicos.
I Mantener para prevenir el transporte de contaminantes del desagüe del piso a la cámara.
J Mantenga despejado el espacio provisto para mantenimiento de rutina e inspeccionar alrededor del equipo de ventilación.
K Investigar y rectificar.
* Las frecuencias mínimas pueden ser aumentadas o disminuidas si está indicado en el Manual O&M.
330
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
D
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Operación y Mantenimiento
14.fm Page 331 Thursday, March 3, 2016 2:14 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
14.
DISEÑO DE CONSERVACION DE ENERGIA
Sostenibilidad
El reconocimiento del impacto de las actividades de la industria de la construcción en el ecosistema de la tierra está cambiando la manera de aproximarse al diseño, construcción, operación,
mantenimiento, reutilización y demolición de lo que crea—es decir direccionando las consecuencias ambientales y económicas a largo plazo de sus acciones. Mientras este diseño sostenible
ético—o de sostenibilidad—cubre las cosas más allá del ámbito de Calefacción, Ventilación, Aire
Acondicionado y refrigeración (HVAC&R), el diseño para el uso eficiente de los recursos de
energía es un elemento clave de diseño sostenible.
La aproximación básica al diseño de energía eficiente es reduciendo las cargas y potencia
requerida, mejorando los sistemas de transporte y proporcionando componentes eficientes y controles
“inteligentes.” Esto incluye entendiendo la relación entre energía y potencia, manteniendo simplicidad,
utilizando presupuestos autoimpuestos y aplicando energía-prácticas de diseño inteligente.
Un ejemplo de diseñadores de presupuesto han fijado para sí mismos para edificios de oficinas en un clima típico de Estados Unidos:
Iluminación instalada 0.8 W/pie2 (9 W/m2)
Potencia térmica
20 Btu/h·pie2 (70 W/m2)
Espacio sensible de
2
2 Cabeza de sistema
15 Btu/h·pie (45 W/m ) hidráulico
65 pie agua (180 kPa)
enfriamiento
Espacio de carga de
10 Btu/h·pie2 (30 W/m2) Enfriador de agua
0.50 kW/ton (0.14 kW/kW)
calefacción
(agua-refrigerada)
Presión de sistema de 3.0 in. agua (0.75 kPa) Auxiliares de
0.12 kW/ton (0.035 kW/kW)
ventilación
agua refrigerada
Circulación de aire
1 cfm/pie2 (5 L/s·m2)
Energía eléctrica anual 15 kW/pie2·y (160 kW/m2·y)
2
Energía eléctrica global 3.0 W/pie2 (30 W/m2) Energía térmica anual 5 Btu/pie2 ·y°F·día
(30 W/m ·y·°C·día)
Entonces, como el diseño procede, compare con el presupuesto:
1. Minimice el impacto de los requisitos funcionales del edificio—para reducir, redistribuir
o cambiar (retraso) cargas.
2. Minimice cargas—buscar en el pico y operar con carga parcial.
3. Maximice la eficiencia del subsistema—incluyendo oportunidades para reclamar, redistribuir y almacenar energía para uso futuro.
4. Estudiar maneras alternativas para integrar el subsistema en el edificio—utilice soluciones de diseño fácil de entender para fomentar la simplicidad de operación.
•
•
•
•
•
•
•
•
•
•
Considere sistemas separados para servir áreas esperadas para operar en muy diferentes
horarios o condiciones de diseño.
Organizar los sistemas así los espacios con cargas relativamente constantes y tiempo independiente son servidos por sistemas separados de los sistemas que sirven los espacios perimetrales.
Suministro de secuencia de refrigeración y calefacción para prevenir la operación
simultánea de sistemas de calefacción y refrigeración al mismo espacio.
Provea controles para permitir la operación en un modo ocupado y en un modo desocupado.
Donde la temperatura diurna oscila y los niveles de humedad permiten, considere el acoplamiento del aire de distribución y masa del edificio para permitir al enfriamiento de la
noche reducir el requisito de refrigeración mecánica del día.
Donde el clima lo permite, considere sistemas de modo mixto de HVAC y ventilación natural.
Seleccione los dispositivos de conversión de energía adaptado a incrementos de carga.
Seleccione el equipo más eficiente práctica tanto al diseño y condiciones de operación de
carga parcial.
Considere seriamente técnicas de compra de ciclo de vida para dispositivos de gran potencia.
Transportar energía por la mayoría de los medios más de eficiencia energética.
Proporcionar sistema de control inteligente que provean información a operadores y gerentes.
Sumario
En los sistemas de diseño de Calefacción, Ventilación, Aire Acondicionado y Refrigeración
(HVAC&R), la necesidad de abordar los problemas inmediatos como económicos, rendimiento y
restricciones de espacios no debería impedir a los diseñadores de considerar completamente diferentes fuentes de energía. Considere la viabilidad y confianza de los recursos de energía para la
331
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Diseño de Conservacion
de Energia
•
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Diseño de Sistema de Calefacción, Ventilación, Aire Acondicionado y
Refrigeración (HVAC&R)
14.fm Page 332 Thursday, March 3, 2016 2:14 PM
Norma 90.1-2010 de ANSI/ASHRAE/IES, Norma Energética para Edificios Excepto Edificios
Residenciales de Poca Altura.
La norma incluye requisitos mínimos de eficiencia energética para edificios nuevos o
porciones de edificios y sus sistemas, sistemas nuevos y equipo en los edificios existentes.
Hay un movimiento fuerte para proveer considerablemente mayor ahorro de energía
que lo requerido por esta norma. La norma ha tenido frecuentes adendas y es revisada cada
tres años.
Camino Prescriptivo para Flexibilidad de Cumplimientos
Sección 5. Envolvente del Edificio. Las Tablas en la norma cubren ocho zona climáticas (ver el siguiente mapa del Apéndice B) para ocupaciones no residenciales, residencial
y semi-climatizadas para valores de aislamiento mínimos permitidos de elementos envolventes y ganancia máxima permitida de calor solar de fenestración.
Sección 6. HVAC; eficiencias de equipo mínimas. Controles requeridos. La potencia del
ventilador permitida para sistemas de aire de suministro (<9400 L/s, 1.9 lW/1000 L/s para
sistemas CAV, 2.7 kW/1000 L/S para sistemas VAV; para 9400 L/s o mayor, 1.7 kW/1000 L/s
CAV, 2.4kW/1000 L/s VAV). Sistemas hidrónicos con potencia de bomba excediendo 10 hp
(7 kW) y teniendo válvulas de control que cambian la tasa de flujo con carga serán designados
para flujo variable, capaz de reducir el flujo 50% (si la cabeza de la bomba excede 300kPa y el
motor excede 37kW, la demanda del motor no debe exceder del 30% al 50% de flujo). Los
ventiladores de los equipos de rechazo de calor con motor 7.5 hp (5.6 kW) o más grande
automáticamente será capaz de reducir la velocidad del ventilador con carga a 3/3 o menos del
diseño. La energía de escape será recobrable 50% para sistemas con ambos suministros de
5000 cfm (2400 L/s) o mayor y mínimo 70% aire exterior. Los sistemas de recuperación de
calor son requeridos para sistemas de servicio de agua caliente donde la instalación opera
24 horas del día, el rechazo de calor excede 6.000.000 Btu/h (1800 k/W) y el servicio de carga
de calentamiento de agua excede 1.000.000 Btu/h (300 W). Al calentar espacios descubiertos,
calor radiante deberá utilizarse.
Sección 7. Servicio de calentamiento de agua—eficiencias mínimas del equipo.
Sección 8. Potencia: Conductores de alimentación dimensionados par caída máxima
de voltaje del 2% en la carga de diseño, conductores de circuito derivado3%.
Sección 9. Iluminación. Limitaciones en las densidades de poder de iluminación, controles requeridos.
Sección 10. Otros equipos. Eficiencias mínimas permitidas del motor eléctrico.
Alternativa a los Métodos Prescriptivos de Cumplimiento
Sección 11. Método de presupuesto de costo de energía.
Norma 90.2-2007de ASHRAE, Diseño de Eficiencia Energética de Edificios Residenciales de
Baja Altura
Requisitos mínimos prescritos para envolvente y equipo con el costo de energía anual
alterno del método de cumplimiento.
Norma 100.2006 de ASHRAE, Conservación de energía en Edificios Existentes.
Un edificio o complejo de edificios cumple cuando los siguientes requisitos se han
cumplido y registrados en la Forma A de la norma y la parte que determina el cumplimiento ha (1) conducido una encuesta de energía como lo requerido por la norma en la
Sección 5, (2) declarado por escrito que los requisitos de operación y mantenimiento en la
Sección 5 han sido cumplidos y (3) ha declarado por escrito que el edificio y modificaciones en la Sección 7 se han cumplido.
Requisitos más estrictos más detallados pueden esperarse en ediciones futuras de la
norma.
332
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Diseño de Conservacion
de Energia
Normas de Eficiencia Energética
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
operación a largo término del edificio. Normas de energía y legislación representan sólo lo mínimo que puede obtenerse, esforzarse para utilizar mejor la energía.
14.fm Page 333 Thursday, March 3, 2016 2:14 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
333
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Diseño de Conservacion
de Energia
Figura 14.1 Zonas Climáticas para Ubicaciones en los Estados Unidos [Std 90. 1-2010, Fig. B-1]
334
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
250 a 350%
250 a 300%
Constante
65%
Medio
25%
250 a 300%
Constante
95%
Alto
125 a 150%
250 a 300%
Constante
Clasificación de Velocidad
a
60%
Medio
Expresado como porcentaje de par nominal de caballos de fuerza.
Factor de Potencia de Carga Completa
Eficiencia
95%
Alto
Constante
250%
250%
3500 a 1750
3450 a 1725
3450 a 1725
3450 a 1725
Velocidades de Carga Completa a 60 Hz
(Dos Polos, Cuatro Polos)
Para
Desglose de
Rotor Enclavado
Tasas, hp (kW)
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Ninguno
Interruptor
centrifugo
0.05 a 5
(0.04 a 3.7)
Interruptor
centrífugo
0.05 a 0.5
(0.04 a 0.4)
Interruptor
centrífugo
0.05 a 5
(0.04 a 3.7)
Método de Arranque
25%
125%
Constante o
ajustable
60%
Bajo
3100 a 1550
0.01 a 0.25
(0.04 a 0.19)
Ninguno
Recorrido
Polo Sombreado
80%
Alto-Medio
Constante
150 a 350%
250 a 350%
3500 a 1750
0.5 (0.4) y arriba
Controlador de motor
Polifásico,
60-Hz
ELECTRICAL
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Curvas Par de Velocidad
0.05 a 5
(0.04 a 3.7)
Recorrido
Arranque de
Capacitor
Carrera de
Capacitor
Inicio
Inicio
Recorrido
Recorrido
Recorrido
Inicio
Arranque de
Capacitor
Carrera de
Inducción
Capacitor
Dividido
Permanente
Características de Motores AC (No Hermético) [2012S, Ch 45, Tbl 4]
Fase Dividida
Tabla 15.1
15.
Inicio
Diagrama de Conexión
Electrical
15.fm Page 334 Thursday, March 3, 2016 2:13 PM
15.fm Page 335 Thursday, March 3, 2016 2:13 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 15.2 (I-P)
Amperios de Motores a Plena Carga
Los valores son para motores con características de par normal a velocidades con correa habituales.
Electrical
335
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tamaño de AC Trifásico Jaula Tamaño de
de Ardilla y Rotor
Arranque
Caballos Arranque
Caballos
Monofásico AC
Recomendado Devanado (Tipo Recomendado
de
de
Trifásico
Inducción)
Monofásico
Fuerza
Fuerza
230 V 460 V 200 V 230 V 460 V
230 V
115 V 200 V 230 V
1/6
00
4.4
2.5
2.2
1/6
1/4
00
5.8
3.3
2.9
1/4
1/2
00
00
2.3
2
1
00
9.8
5.6
4.9
1/2
3/4
00
00
3.2
2.8
1.4
00
13.8 7.9
6.9
3/4
1
00
00
4.1
3.6
1.8
00
16
9.2
8
1
1.5
00
00
6.0
5.2
2.6
0
20
11.5
10
1.5
2
0
00
7.8
6.8
3.4
0
24
13.8
12
2
3
0
0
11.0 9.6
4.8
1
34
19.6
17
3
5
1
0
17.5 15.2 7.6
1
56
32.2
28
5
7.5
1
1
25.3 22
11
2
80
46
40
7.5
10
2
1
32.2 28
14
2
100 57.5
50
10
15
2
2
48.3 42
21
3
15
20
3
2
62.1 54
27
20
25
3
2
78.2 68
34
25
30
3
3
92
80
40
30
40
4
3
119.6 104
52
40
50
4
3
149.5 130
65
50
60
5
4
177.1 154
77
60
75
5
4
220.8 192
96
75
100
5
4
285.2 248 124
100
125
6
5
358.8 312 156
125
150
6
5
414 360 180
150
200
6
5
552 480 240
200
15.fm Page 336 Thursday, March 3, 2016 2:13 PM
Amperios de Motores a Plena Carga
Electrical
336
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Los valores son para motores con características de par normal a velocidades con correa habituales.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 15.2 (SI)
Tamaño de Trifásico AC Jaula Tamaño de
de Ardilla y Rotor
Arranque
Potencia Arranque
Potencia
Monofásico AC
Nominal, Recomendado Devanado (Tipo Recomendado
Nominal,
Trifásico
Inducción)
Monofásico
W
kW
230 V 460 V 200 V 230 V 460 V
230 V
115 V 200 V 230 V
0.12
00
4.4
2.5
2.2
0.12
0.19
00
5.8
3.3
2.9
0.19
0.37
00
00
2.3
2
1
00
9.8
5.6
4.9
0.37
0.56
00
00
3.2
2.8
1.4
00
13.8 7.9
6.9
0.56
0.75
00
00
4.1
3.6
1.8
00
16
9.2
8
0.75
1.12
00
00
6.0
5.2
2.6
0
20
11.5
10
1.12
1.5
0
00
7.8
6.8
3.4
0
24
13.8
12
1.5
2.2
0
0
11.0 9.6
4.8
1
34
19.6
17
2.2
3.7
1
0
17.5 15.2 7.6
1
56
32.2
28
3.7
5.6
1
1
25.3 22
11
2
80
46
40
5.6
7.5
2
1
32.2 28
14
2
100 57.5
50
7.5
11
2
2
48.3 42
21
3
11
15
3
2
62.1 54
27
15
19
3
2
78.2 68
34
19
22
3
3
92
80
40
22
30
4
3
119.6 104
52
30
37
4
3
149.5 130
65
37
45
5
4
177.1 154
77
45
56
5
4
220.8 192
96
56
75
5
4
285.2 248 124
75
93
6
5
358.8 312 156
93
112
6
5
414 360 180
112
150
6
5
552 480 240
150
15.fm Page 337 Thursday, March 3, 2016 2:13 PM
Fórmulas Eléctricas Útiles
Encontrar
Corriente
Contínua
Monofásico
Trifásico
Amperios cuando la
potencia es conocida
hp  746
--------------------E
hp  746
-----------------------EF
hp  746
----------------------------------------1.73  E    F
Amperios cuando el
kilovatio es conocido
kW  1000
-------------------------E
kW  1000
-------------------------EF
kW  1000
------------------------------1.73  E  F
kVA  1000
----------------------------E
kVA  1000
----------------------------1.73  E
IEF
----------------------1000
I  E  1.73  F
---------------------------------------1000
IE
-----------1000
I  E  1.73
----------------------------1000
I EF
--------------------------------746
I  E  1.73    F
-------------------------------------------------746
Amperios cuando
kVA es conocido
IE
-----------1000
Kilovatios
kVA
I E
---------------------746
Potencia—(Salida)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 15.3 (I-P)
1 = amperios; E = voltios;  = Eficiencia expresada como decimal; F = factor de potencia; kW = kilovatios;
kVA = kilovoltios-amperes; hp = caballo de fuerza.
Tabla 15.3 (SI)
Encontrar
Monofásico
Trifásico
1000P
1000 P-------------- F 
1000 P
---------------------- 1.73F 
1000 kVA/
1000 kVA/(1.73)
kVA
Desconectado, kW
IE/1000
IE/1000
1.73 IE/1000
IEF/1000
  IEF/1000
1 = amperios; E = voltios;  = eficiencia expresada como decimal; F = factor de potencia; P = kilovatios;
kVA = kilovoltios-amperios
Controladores del Motor
Los controladores del motor de inducción velocidad constante trifásico son por lo general de
voltaje completo excepto cuando la corriente de arranque debe ser reducida en motores grandes
para cumplir con las limitaciones del sistema de potencia; tales controladores pueden ser de varios
tipos de fila. Todos son utilizados para arrancar y parar el motor e incluye protección de sobrecorriente.
Accionamientos de Velocidad Variable (VSDs)
337
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Electrical
Con mucho los medios más eficientes de energía de variar el flujo de ventiladores y bombas
accionadas por motores eléctricos son los (VSDs). Su aplicación involucra consideración
cuidadosa de sus efectos (aquí VSD es considerada sinónimo con accionamiento de frecuencia
variable [VFD], accionamiento modulado ancho de pulso [PWM drive], accionamiento de velocidad ajustable [ASD] y accionamiento de frecuencia ajustable [AFD].) Un accionamiento de
Velocidad Variable (VSD) consiste de un controlador de modulación de ancho de pulso con transistores bipolares de puerta aislada (IGBTs) y un motor de inducción. El transistor bipolar de puerta
aislada (IGBT) cambia las características de formas de ondas aplicadas a un motor debido a la
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Amperios cuando la
potencia es conocida
Amperios cuando kVA
es conocido
Fórmulas Eléctricas Útiles
Corriente
Contínua
15.fm Page 338 Thursday, March 3, 2016 2:13 PM
Electrical
338
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 15.1 Pico de Voltaje de Motor y Límites dv/dt
(Reimpreso de la Norma NEMA, MG1, Parte 30,
por permiso de la Asociación Nacional de Fabricantes Eléctricos)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
velocidad en el cual los ciclos del transistor bipolar de puerta aislada (IGBT) encienden y apagan.
A la velocidad de conmutación de hasta 20 k Hz la impedancia en el cable conectado es mucho
menor que la impedancia del motor, particularmente para motores pequeños, causando reflectancia de pulso a los terminales del motor para formar voltaje alto perjudicial. La norma de motor
MG1 de la Asociación Nacional de Fabricantes Eléctricos (NEMA) establece los limites de accionamiento modulado de ancho de pulso (PWM) y establece un pico de 1600 V y un mínimo de
tiempo de subida de 0.1 para motores nominal inferiores a 600 V. Voltaje máximo de fabricante
típico soportan niveles que van de 1000V a 1800 V. Cuando se especifica motores para operación
en accionamientos de velocidad variable (VSDs), el voltaje que soporta el nivel basado en el dv/dt
del accionamiento y la distancia del cable conocido debe ser especificado.
Armónicas causadas por la porción de un accionamiento de velocidad variable (VSD)
afectando la alimentación de línea y son denominados armónicos del lado de la red. Líneas de salida armónicas son causadas únicamente por la sección de inversor del accionamiento de velocidad
variable (VSD) y son conocidas como lado de la carga o armónicas del motor. Generalmente, el
accionamiento modulado de ancho de pulso (PMW) que contienen reacción de barra interna o
reactores de línea AC trifásica no causan interferencia con otros equipos eléctricos. Puede haber
problemas cuando un accionamiento de velocidad variable (VSD) es conmutado a un generador
de reserva, o cuando los capacitores de corrección de factor de potencia son utilizados.
15.fm Page 339 Thursday, March 3, 2016 2:13 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Sistemas Fotovoltaicos
Figura 15.2 Voltaje de Corriente Representativo y Curvas de Voltaje de Potencia
para Dispositivos Fotovoltaicos [2012S, Ch 37, Fig 30]
Pmax = Isc Voc FF
Los parámetros típicos de una célula son la densidad de corriente JSC = 206 mA/in.2; Va = 0.58 V;
Vmax = 0.47 V; FF = 0.72; y Pmax = 2273 mW.
Las baterías de plomo ácido de ciclo profundo son comúnmente cableadas para que la potencia pueda ser suministrada en la noche o cuando el sistema fotovoltaico (PV) no pueda cumplir la
demanda. Los controles de carga de la batería regulan la potencia de los módulos para prevenir
sobre carga de la batería. Los inversores convierten la corriente directa en corriente alterna.
Estructuras de montaje y cableado completan un sistema fotovoltaico (PV).
339
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Electrical
Un módulo fotovoltaico (PV) está compuesto de una serie de células que proveen voltaje de
operación alrededor de 15 V, encapsulado en fábrica, con una caja de conexiones para el cableado
a oros módulos u otros equipos eléctricos.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Las células fotovoltaicas (PV) convierten la luz del sol directamente en electricidad. Una
célula fotovoltaica consiste de un material fotovoltaico activo, rejillas de metal, recubrimientos
antirreflejantes y material de apoyo, un dispositivo de dos terminales con cables negativos y positivos. La corriente depende de la cantidad de luz en la célula y del voltaje externo aplicado.
Cuando la célula está cortocircuitada, la corriente Isc está al máximo y el voltaje a través de la
célula es cero. Cuando el circuito fotovoltaico (PV) está abierto, el voltaje está al máximo Voc y la
corriente es cero. Entre circuito abierto y corto, la potencia de salida es mayor de cero. Al iluminar
y cargar una célula fotovoltaica (PV) con voltaje igual a las células Vmax la potencia de salida es
maximizada. La célula puede ser cargada usando cargas de resistencia, cargas electrónicas o baterías. Un parámetro adicional, factor de relleno FF puede ser calculado de tal manera que
16.fm Page 340 Thursday, March 3, 2016 12:53 PM
Absorbentes y Desecantes
ABSORBENTES Y DESECANTES
Figura 16.1 (I-P) Ciclo de Desecante [2013F, Ch 32, Fig 3]
340
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Los absorbentes son materiales que tienen una habilidad de atraer y retener otros gases o
líquidos. Ellos pueden ser utilizados para atraer gases o líquidos a más de vapor de agua, una característica que los hace muy útiles en el proceso de separación de químicos. Los desecantes son
unos subconjuntos de los absorbentes; tienen una particular afinidad por el agua.
Madera, fibras naturales, arcillas y otros materiales sintéticos atraen y liberan la humedad
como los desecantes comerciales lo hacen, pero ellos carecen la capacidad de retención. Además,
los desecantes comerciales continúan en atraer humedad aún cuando el aire circundante es bastante seco.
Todos los desecantes atraen humedad hasta que alcanzan equilibrio con el aire circundante.
La humedad es usualmente removida del desecante por regeneración, calentándolo a temperaturas
entre 120 y 500°F (50 y 260°C) y exponiéndolos a una corriente de aire de barrido. Después que
el desecante se seca, debe ser enfriado para que pueda atraer humedad una vez más. La sorción
siempre genera calor sensible igual al calor latente del vapor de agua tomado por el desecante más
un calor adicional de sorción que varía entre el 5 y 25% del calor latente del agua de vapor. Este
calor es transferido al desecante y al aire circundante.
Atraer y retener la humedad está descrito como adsorción o absorción. La adsorción no cambio al desecante, excepto por el aumento de peso (masa) de vapor de agua. Absorción, por otra
parte cambia el desecante. Un ejemplo de un absorbente es la sal de mesa, la cual cambia de
sólido a líquido a medida que absorbe humedad.
La economía de operación del desecante depende en el costo de la energía de mover un material dado a través de este ciclo. La deshumidificación de aire (cargar el desecante con vapor de
agua) generalmente procede sin entrada de energía distinta de los costos del ventilador y bomba.
La porción mayor de energía es invertido en regenerar el desecante (moviendo del punto 2 al
punto 3) y enfriando el desecante (del punto 3 al punto 1).
En equipo comercial, los desecantes duran de 10.000 a 100.000 (10.000 a 100.000) h y más
antes de ser reemplazadas. Dos mecanismos causan pérdida de la capacidad del desecante: (1)
cambio en las características de absorción a través de reacciones químicas con contaminantes y
(2) pérdida del área de superficie efectiva a través de la obstrucción o degradación hidrotermal.
Los absorbentes líquidos son más susceptibles a reacción química con contaminantes de corriente de aire que son sólidos. Absorbentes sólidos tienden a ser menos reactivos químicamente y
más sensitivas a obstrucción, una función del tipo y calidad de material de partículas en la corriente de aire.
En aplicaciones de aire acondicionado, el equipo desecante está diseñado para minimizar la
necesidad de reemplazar el desecante de la misma manera que los sistemas de enfriamiento de
compresión de vapor son diseñados para evitar la necesidad para reemplazo del compresor.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
16.
16.fm Page 341 Thursday, March 3, 2016 12:53 PM
Absorbentes y Desecantes
Ciclo de Desecante [2013F, Ch 32, Fig 3]
341
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.2 Diagrama de Flujo para Deshumidificador Absorbente de Líquidos
[2012S, Ch 24. Fig 2]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 16.1 (SI)
Figura 16.3 Diagrama de Flujo para Unidad de Absorbente de Líquido con Superficie Extendida
de Medios de Contacto del Aire [2012S, Ch 24. Fig 3]
342
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.4 Unidad de Deshumidificación Típico Rotativo Sólido [2012S, Ch24, Fig 7]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Absorbentes y Desecantes
16.fm Page 342 Thursday, March 3, 2016 12:53 PM
16.fm Page 343 Thursday, March 3, 2016 12:53 PM
343
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Para gel de sílice, medios acanalados soporte estructurado, con la profundidad de la base de
16 pulg. en la dirección de la corriente de aire, la relación del aire de proceso al aire de reactivación es aproximadamente 3:1. El aire de proceso entra en la máquina en condiciones de confort
normal e 70°F (21°C), 50% rh (8.0 gramos por kilogramo de aire seco).
Absorbentes y Desecantes
Ambos desecantes líquido y sólido pueden utilizarse en el equipo diseñado para el secado de
aire y gases.
El rendimiento del desecante depende en el equipo, las características de los desecantes, temperatura inicial y contenido húmedo del gas a ser secado y métodos de reactivación. Las unidades
ensambladas en fábrica están disponibles hasta una capacidad cerca de 80.000 cfm (38 m3/s)
En la deshumidificación del desecante líquido, la humedad es absorbida en el aire debido a la
diferencia en la presión de vapor de agua entre el aire y la solución desecante. Una concentración
de solución mayor resulta en una presión de vapor de agua inferior. Una temperatura de solución
inferior resulta en una presión de vapor de agua inferior. Mediante el control de temperatura y
concentración de la solución desecante, el acondicionador puede enviar aire a una humedad y temperatura controlada con precisión. La unidad deshumidifica el aire durante el clima húmedo y lo
humidifica durante el clima seco.
Cuando deshumidifica, el agua es automáticamente removida del desecante líquido en el
regenerador para mantener el desecante en la concentración adecuada. Cuando el acondicionador
está siendo utilizado para humidificar el aire, el ventilador del regenerador y la bomba de solución
desecante son típicamente parados para ahorrar energía. Debido a que el acondicionador y regenerador son unidades separadas, pueden estar en ubicaciones diferentes y conectadas por tubería.
Esto puede sustancialmente bajar el costo de los conductos y requerir espacio mecánico. Comúnmente, un regenerador único sirve a muchas unidades del acondicionador.
El regenerador puede dimensionarse para que coincida la carga de deshumidificación de la
unidad o unidades del acondicionador. La capacidad del regenerador es afectada por las temperaturas de la fuente de calor del regenerador; temperaturas de la fuente más altas producen mayor
capacidad. La capacidad del regenerador también es afectada por la concentración del desecante;
concentración más alta resulta en capacidad reducida.
La humedad relativa del aire que sale del acondicionador es prácticamente constante por una
concentración de un desecante dado, entonces la capacidad del regenerador puede ser mostrada
como una función de humedad relativa del aire entregado y la temperatura de la fuente de calor
del regenerador.
Un deshumidificador del desecante sólido giratorio típico puede tener una base de perlas de
material granular o puede ser dividido finamente e impregnado a través de un medio estructurado
que se asemeja a un cartón corrugado enrollado en un tambor, para que el aire pase libremente a
través de canales alineados longitudinalmente a través del tambor.
El desecante puede ser un solo material, como un gel de sílice, o una combinación, como un
cloruro de litio seco mezclado con zeolitas. El amplio ámbito de aplicaciones para sistemas de
deshumidificación requiere esta flexibilidad para minimizar los costos de instalación y operación.
Variables de rendimiento para diseño de sistema para aire de proceso y aire de reactivación
incluye
• temperatura de aire de entrada
• contenido de humedad, y
• velocidad en la cara de la base del desecante.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Deshumidificación del Desecante
16.fm Page 344 Thursday, March 3, 2016 12:53 PM
Absorbentes y Desecantes
Figura 16.5 (I-P) Efecto de Cambios en la Velocidad de Aire de Proceso en Salida de Humedad del
Deshumidificador [2012S, Ch 24, Fig 8]
Efecto de Cambios en la Velocidad de Aire de Proceso en Salida de Humedad del
Deshumidificador [2012S, Ch 24, Fig 8]
344
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.5 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Modelo del Típico Deshumidificador Desecante Sólido Rotativo
16.fm Page 345 Thursday, March 3, 2016 12:53 PM
Absorbentes y Desecantes
345
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.6 (SI) Efecto de Cambios en Humedad de Entrada de Aire de Proceso en
Salida de Humedad del Deshumidificador [2012S, Ch 24, Fig 9]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 16.6 (I-P) Efecto de Cambios en Humedad de Entrada de Aire de Proceso en
Salida de Humedad del Deshumidificador [2012S, Ch 24, Fig 9]
Figura 16.7 (I-P) Efecto de Cambios en la Temperatura de Entrada de Aire de Reactivación en la
Salida de Humedad del Deshumidificador [2012S, Ch 24, Fig 10]
Efecto de Cambios en la Temperatura de Entrada de Aire de Reactivación en la
Salida de Humedad del Deshumidificador [2012S, Ch 24, Fig 10]
346
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.7 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Absorbentes y Desecantes
16.fm Page 346 Thursday, March 3, 2016 12:53 PM
16.fm Page 347 Thursday, March 3, 2016 12:53 PM
Absorbentes y Desecantes
Efecto de Cambios en Humedad de Entrada de Aire de Proceso en la Temperatura
de Salida del Deshumidificador [2012S, Ch 24, Fig 11]
347
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.8 (SI)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 16.8 (I-P) Efecto de Cambios en Humedad de Entrada de Aire de Proceso en la
Temperatura de Salida del Deshumidificador [2012S, Ch 24, Fig 11]
Figura 16.9 (I-P) Efecto de Cambios en Temperatura de Entrada de Aire de Reactivación en la
Temperatura de Salida del Deshumidificador [2012S, Ch 24, Fig 12]
348
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.9 (SI) Efecto de Cambios en Temperatura de Entrada de Aire de Reactivación en la
Temperatura de Salida del Deshumidificador [2012S, Ch 24, Fig 12]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Absorbentes y Desecantes
16.fm Page 348 Thursday, March 3, 2016 12:53 PM
16.fm Page 349 Thursday, March 3, 2016 12:53 PM
Absorbentes y Desecantes
349
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 16.10 (SI) Datos de Rendimiento Térmico para Deshumidificador Desecante
Sólido Rotativo [2012S, Ch 24, Fig 14]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 16.10 (I-P) Datos de Rendimiento Típico para el Deshumidificador Desecante
Sólido Rotativo [2012S, Ch 24, Fig 14]
17.fm Page 350 Thursday, March 3, 2016 12:57 PM
Calor Combinado y
Sistemas Electricos
CALOR COMBINADO Y SISTEMAS ELECTRICOS
Calor combinado y energía (CHP) es la producción simultánea de energía (potencia)
mecánica o eléctrica y energía térmica útil de una fuente de energía única. Energía térmica recuperada del combustible utilizado en motores alternativos, turbinas o células de combustible.
El calor combinado y energía (CHP) puede operar en un ciclo de contrapresión, tocando
fondo o combinado. La Figura 17.1 muestra un ejemplo de configuraciones de contrapresión y
tocando fondo. En un ciclo de contrapresión, la energía del combustible genera ejes o energía
eléctrica y la energía térmica de la corriente existente es recuperada para otras aplicaciones como
procesar calor para sistemas de calefacción o enfriamiento. En un ciclo de tocar fondo, el eje o la
energía eléctrica se genera a partir de la última energía térmica que queda después de que la
energía térmica de nivel más alto ha sido utilizada para satisfacer las cargas térmicas. Un ciclo de
contrapresión típico recupera calor del proceso para generar electricidad. Un ciclo combinado utiliza salida térmica de una fuente primaria para generar potencia en el eje adicional (ej. la combustión de la turbine de escape genera vapor para un generador de turbina a vapor).
Sistemas de calor combinado y energía (CHP) de rejilla aislada, en los cuales la salida eléctrica es utilizada en el sitio para satisfacer todos los requisitos térmicos y eléctricos en sitio, hacen
referencia a sistemas de energía total. Sistemas de calor combinado y energía (CHP) de rejilla
paralela, los cuales están activamente atados a la red de suministro eléctrico, pueden en una base
contractual o tarifa, intercambiar energía con o reducir la carga en la empresa de servicio público
(reduciendo así la demanda de capacidad). Esto puede eliminar o disminuir la necesidad para
redundancia en el sitio de la capacidad de generación de respaldo y permite la operación a la máxima eficiencia térmica al satisfacer la carga térmica de la instalación; esto puede producir más
energía eléctrica que las necesidades de la instalación.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 17.1 Ciclos de Calor Combinado y Energía (CHP) [2012S, Ch 7, Fig 1]
350
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
17.
X
Fuente: Adaptado de NRL (2003)
DG = Generación Distribuida (generación de energía en el sitio)
Compartimentos de
Depósitos de
Combustibles:
5 kW a 2 MW
X
Microturbinas:
30 a 500 kW
X
X
Turbinas a vapor:
500 kW a 100 MW
X
X
X
Motores Alternativos:
50 kW a 16 MW
X
X
X
X
X
Sólo Potencia Correccion
Pico de
de Carga
de respuesta afeitar de
Fundamental de demanda
cliente
Turbinas a gas:
500 kW a 50 MW
Energía de
Reserva
X
X
X
X
X
Potencia
Superior
X
X
X
X
Apoyo Red
de
Suministro
Eléctrico
X
X
X
X
X
CHP
Residencial, comercial, Industria ligera
Edificios comerciales, industrias ligeras,
combustibles residuales.
Edificios institucionales/campos, industrial,
combustibles residuales
Comercio grande, institucional, industrial, red de
suministro eléctrico, combustibles residuales.
Edificios comerciales, institucional, industrial, red
de suministro eléctrico (unidades grandes),
combustibles residuales.
Sectores de Mercado Aplicable
Aplicaciones y Mercados para los Sistemas de Generación Distribuida/Calor Combinado y Energía (DG/CHP) [2012S, Ch 7, Tbl 1]
Tecnologías DG
Tabla 17.1
17.fm Page 351 Thursday, March 3, 2016 12:57 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
351
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Calor Combinado y
Sistemas Electricos
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
17.fm Page 352 Thursday, March 3, 2016 12:57 PM
Tabla 17.2
Tasas de Consumo de Combustible [2004S, Ch 7, Tbl 11]
Combustible
Calor Combinado y
Sistemas Electricos
Aceite combustible
Gasolina
Consumo Típico para Diferentes
Tipos de Motores de Gas
Valor Calorífico,
Btu/gal (MJ/m3)
137,000 a 156,000 (38 a 43)
130,000 (36)
Margen de Consumo,
Btu/hp·h (W/W)
7000 a 9000 (0.58 a 0.75)
10,000 a 14,000 (0.83 a 1.17)
Consumo de Gas,
Btu/hp·h (W/W)
8,100 (0.67)
9,200 (0.76)
10,250 (0.85)
Índice de Compresión
Turboalimentador
Aspirado Naturalmente
Aspirado Naturalmente
10.5:1
10.5:1
7.5:1
Tabla 17.3 Porcentaje Mínimo de Reservas de Motores para
Aire Acondicionado y Refrigeración [2004S, Ch 7, Tbl 12]
Nivel del mar
1000 ( 300)
2000 ( 600)
3000 ( 900)
4000 (1200)
5000 (1500)
10,000 (3000)
Aire
Acondicionado
Refrigeración
15
12
10
10
10
10
10
20
17
14
11
10
10
10
Aire
Acondicionado
20
18
16
14
12
10
10
Refrigeración
30
28
26
24
22
20
10
Aire de Ventilación para Salas de Equipos de Máquinas
[2012S, Ch 7, Tbl 10]
Elevación de
Temperatura de Aire
Ambiente,a
°F (°C)
10 (5)
20 (10)
30 (15)
Corriente de aire, cfm/hp (L/s por Kilowatt)
Silenciador y
Tubo de Escapeb
Silenciador y
Tubo de Escapec
Aire o RadiadorMotor Refrigeradod
140 (100)
70 (50)
50 (35)
280 (190)
140 (100)
90 (65)
550 (380)
280 (200)
180 (130)
a Escape menos entrada
b Aislado o encerrado en conducto de ventilación.
c Sin aislamiento.
d Calor descargado en sala de máquina.
352
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tabla 17.4
Radiador de Salida de
Turboalimentador
Aspirado Naturalmente
Altitud,
pie (m)
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tamaño del Motor
17.fm Page 353 Thursday, March 3, 2016 12:57 PM
Procedimiento
1. Tomar muestra de aceite lubricante
Cambiar filtros de aceite lubricante
Limpíar depurador de aire, combustible
Limpiar filtros de combustible
Cambiar aceite lubricante
Limpiar respiradero del cárter
Ajustar válvulas
Lubricar tacómetro, bomba de cebado de
8.
combustible y chumaceras de mando auxiliares
Servicio de sistema de encendido; ajuste de
9. distancia de interruptor, sincronización,
separación de los electrodos de la bujía, magneto.
10. Comprobar magneto transistorizado
Lubricación nivelada de sistema de tubería de
11.
aceite
12. Cambiar depurador de aire
Reemplazar sellos del turboalimentador y
13.
cojinetes
1000 a 2000 (bomba
de combustible N/A)
N/A
1000 a 2000
N/A
6000 a 8000
3000 a 5000
3000 a 5000
2000 a 3000
2000 a 3000
4000 a 8000
4000 a 8000
8000 a 12,000
(8000 a 12 000)
8000 a 12,000
(8000 a 12 000)
24,000 a 36,000
(24 000 a 36 000)
24,000 a 36,000
(24 000 a 36 000)
353
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Reemplazar aros de pistón, revestimiento del
cilindro (si es aplicable), cojinetes de metal y
14. cabezales de cilindro; reacondicionar o
reemplazar turboalimentadores; reemplazar
empaques y sellos.
Igual al numeral 14, más reacondicionar o
15. reemplazar cigüeñal, reemplazar todos los
cojinetes
1000 a 2000
Calor Combinado y
Sistemas Electricos
2.
3.
4.
5.
6.
7.
Horas entre Procedimientos
Motor a Diesel
Motor a Gas
Una vez por mes
Una vez por mes
más una vez en cada más una vez en cada
cambio de aceite
cambio de aceite
350 a 750
500 a 1000
350 a 750
350 a 750
500 a 750
N/A
500 a 1000
1000 a 2000
350 a 700
350 a 750
1000 a 2000
1000 a 2000
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 17.5 Mantenimiento de Motor Recomendado [2012S, Ch 7, Tbl 13]
Figura 17.2 (I-P) Curva Funcional para Motor a Gas Impulsado, Típico de 100 Toneladas,
Enfriador Alternativo [2012S, Ch 7, Fig 64]
354
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 17.2 (SI) Curva Funcional para Motor a Gas Impulsado, Típico de 350 kW,
Enfriador Alternativo [2012S, Ch 7, Fig. 64]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Calor Combinado y
Sistemas Electricos
17.fm Page 354 Thursday, March 3, 2016 12:57 PM
17.fm Page 355 Thursday, March 3, 2016 12:57 PM
Calor Combinado y
Sistemas Electricos
355
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 17.4 Balance Calorífico para Motor Turboalimentador [2012S, Ch 7, Fig 46]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 17.3 Balance Calorífico para Motor Aspirado Naturalmente [2012S, Ch 7, Fig. 45]
Figura 17.5 Calor Combinado y Energía (CHP) Diagrama Límite
de Energía de Calefacción y Potencia [2012S, Ch 7, Fig 6]
Tabla 17.6 Temperaturas Normalmente Requeridas para
Varias Aplicaciones de Calefacción [2012S, Ch 7, Tbl 17]
Tabla 17.7
Temperatura, °F (°C)
190 a 245 (90 a 120)
120 a 250 (50 a 120)
120 a 200 (50 a 93)
150 a 250 (66 a 120)
190 a 250 (90 a 120)
212 a 330 (100 a 165)
190 a 350 (90 a 175)
Flujos de Masa de Escape a Plena Carga y Temperaturas
para Varios Motores [2004S, Ch 7, Tbl 6]
Tipo de Motor
Dos ciclos
Soplador – gas cargado
Turboalimentador gas
Soplador – diesel cargado
Turboalimentador diesel
Cuatro ciclos
Gas aspirado naturalmente
Turboalimentador gas
Diesel aspirado naturalmente
Turboalimentador diesel
Turbina a Gas, no regenerativa
Flujo de Masa,
lb/bhp·h (g/[kW·s])
Temperatura,
°F (°C)
16 (2.7)
14 (2.4)
18 (3.0)
16 (2.7)
700 (370)
800 (430)
600 (320)
650 (340)
9 (1.5)
10 (1.7)
12 (2.0)
13 (2.2)
18 a 48* (3.0 a 8.1*)
1200 (650)
1200 (650)
750 (400)
850 (450)
800 a 1050* (430 a 570*)
*Flujos de masas inferiores corresponden a turbinas a gas más eficientes.
356
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Aplicación
Máquinas de refrigeración por absorción
Calefacción de locales
Calefacción de agua (doméstico)
Calefacción en proceso
Evaporación (agua)
Calefacción de combustible de residuo
Productores de potencia auxiliar, con turbinas a vapor o
expansores binarios
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Calor Combinado y
Sistemas Electricos
17.fm Page 356 Thursday, March 3, 2016 12:57 PM
17.fm Page 357 Thursday, March 3, 2016 12:57 PM
Calor Combinado y
Sistemas Electricos
357
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 17.6 (SI) Eficiencia de Turbina a Vapor Sin Condensación de una Sola Etapa
[2012S, Ch 7, Fig 36]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 17.6 (I-P) Eficiencia de Turbina a Vapor Sin condensación de una Sola Etapa
[2012S, Ch 7, Fig 38]
Figura 17.7 Sistema de Calor Combinado y Energía de Extracción Automática de Tubina
[2012S, Ch 7, Fig 59]
Permite la extracción de vapor de escape en una o más estaciones
para que coincida con las condiciones de escape requeridas para varios procesos.
Tabla 17.8 (I-P) Tasas de Vapor Teóricas para Turbinas a Vapor en
Condiciones Comunes, lb/kWh [2012S, Ch 7, Tbl 15, Condensado]
Tabla 17.8 (SI) Tasas de Vapor Teóricas para Turbinas a Vapor en Condiciones
Comunes, kg/kWh [2012S, Ch 7, Tbl 15, Condensado]
Presión de
escape, kPa
6
12
101.8
200
300
400
500
600
700
1000 kPa, 0 K
Supercalentar
4.8
5.4
9.3
12.7
16.5
21.4
27.9
37.5
53.0
1500 kPa, 0 K
Supercalentar
4.5
4.9
7.9
10.2
12.4
14.9
17.7
21.0
25.0
2000 kPa, 50 K
Supercalentar
4.0
4.4
6.7
8.3
9.8
11.4
13.0
14.8
16.7
3000 kPa, 168 K
Supercalentar
3.3
3.5
5.0
5.9
6.7
7.5
8.2
8.9
9.7
358
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Condiciones de Vapor del Regulador
150 psig, 366°F, 200 psig, 388°F,
250 psig, 500°F,
400 psig, 750°F,
Saturado
Saturado
94°F Supercalentar 302°F Supercalentar
2 in. Hg (abs.)
10.52
10.01
9.07
7.37
4 in. Hg (abs.)
11.76
11.12
10.00
7.99
0 psig
19.37
17.51
15.16
11.20
10 psig
23.96
21.09
17.90
12.72
30 psig
33.6
28.05
22.94
15.23
50 psig
46.0
36.0
28.20
17.57
60 psig
53.9
40.4
31.10
18.75
70 psig
63.5
45.6
34.1
19.96
75 psig
69.3
48.5
35.8
20.59
Presión de
Escape
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Calor Combinado y
Sistemas Electricos
17.fm Page 358 Thursday, March 3, 2016 12:57 PM
17.fm Page 359 Thursday, March 3, 2016 12:57 PM
Las turbinas a gas de combustión están disponibles en tamaños de 38 a 644,000 hp (28 a 480 kW),
y pueden quemar una amplia gama de combustibles gaseosos y líquidos. Ellas consisten de una sección
de compresor de aire, un combustor (mezcla de combustible/aire y cámara de combustión), y una sección de turbina de expansión. Las eficiencias térmicas de turbina simple van de 28% a 36% (basado en
el valor calorífico más alto de combustible). Las velocidades de rotación varían de 3600 a 100,000 rpm.
Algunas turbinas utilizan regeneradores y recuperadores como intercambiadores de calor para precalentar el aire de combustión, aumentando la eficiencia de la máquina.
Calor Combinado y
Sistemas Electricos
Figura 17.8 Turbina de Eje único Ciclo Simple [2012S, Ch 7, Fig 22]
Figura 17.10 Diagrama de Entropía de Temperatura para Ciclo Brayton [2012S, Ch 7, Fig 21]
359
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 17.9 Turbinas de Eje único Ciclo Simple [2012S, Ch 7, Fig 23]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Turbinas de Combustión
Figura 17.11 (I-P) Características de
Rendimiento de Motor de Turbina
[2012S, Ch 7, Fig 24]
Figura 17.11 (SI) Características de
´Rendimiento de Motor de Turbina
[2012S, Ch 7, Fig 24]
Células de Combustible
Tabla 17.9
Resumen de las Características de Células de Combustible
[2012S, Ch 7, Tbl 14]
Disponible
Comercialmente
Margen Dimensional
Ácido
Fosfórico
(PAFC)
Oxido Sólido
(SOFC)
Carbonato
Fundido
(MCFC)
Membrana de
Intercambio de
Protones
(PEMFC)
Sí
No
Sí
Sí
100 ta 200 kW 1 kW a 10 MW 250 kW a 10 MW 500 W a 250 kW
Eficiencia (LHV)
40%
45 a 60%
45 a 55%
30 a 40%
Eficiencia (HHV)
36%
40 a 54%
40 a 50%
27 a 36%
Temperatura Operativa
Promedio
Características de
Recuperación de Calor
400°F (200°C) 1800°F (980°C) 1200°F (650°C)
Agua Caliente
Agua caliente,
vapor
Agua caliente,
vapor
200°F (90°C)
140°F (60°C)
agua
Fuente; Adaptada de Foley y Sweetser (2002).
360
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Las células de combustible convierten energía química de un combustible a base de
hidrógeno directamente en electricidad sin combustión. En la célula, un combustible rico en
hidrógeno pasa sobre el ánodo, mientras un gas rico en oxígeno (aire) pasa sobre el cátodo. Los
catalizadores ayudan a dividir el hidrógeno en iones de hidrógeno y electrones. Los iones de
hidrógeno se mueven a través de un circuito externo, proporcionando así una corriente directa a un
potencial de voltaje fijo. Una planta de energía típica de célula de combustible integrado consiste
de un reformador de combustible (procesador), el cual genera gas rico en hidrógeno de combustible, una etapa de potencia (pila) donde ocurre el proceso electromecánico y un acondicionador de
energía (inversor) que convierte la energía eléctrica DC generada en la célula de combustible en
energía eléctrica AC. La mayoría de las aplicaciones de célula de combustible involucran interconectividad con la red eléctrica, de esta manera el acondicionador de energía debe sincronizar las
salidas eléctricas de las células de combustible con la red eléctrica. Un número creciente de aplicaciones de células de combustible son independientes de la red eléctrica para alimentar de forma
fiable los sistemas críticos o remotos.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Calor Combinado y
Sistemas Electricos
17.fm Page 360 Thursday, March 3, 2016 12:57 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 17.13 Célula de Óxido Sólido
(SOFC) [2012S, Ch 7, Fig 29]
Figura 17.12 Célula de Ácido Fosfórico (PAFC)
[2012S, Ch 7, Fig 28]
17.fm Page 361 Thursday, March 3, 2016 12:57 PM
Figura 17.12 Célula de Membrana de Intercambio
de Protones (PEMFC) [2012S, Ch 7, Fig 31]
Figura 17.14 Célula de Carbonato
Fundido (MCFC) [2012S, Ch 7, Fig 30]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
361
Calor Combinado y
Sistemas Electricos
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
18.fm Page 362 Thursday, March 3, 2016 12:59 PM
COMBUSTIBLES Y COMBUSTIÓN
Tabla 18.1 (I-P)
Tamaño
de
Diámetro
Tubería
Interno.
de Acero
pulg
Nominal,
pulg.
Combustibles y Combustión
¼
3/8
½
¾
1
1¼
1½
2
2½
3
4
Capacidad Máxima de Tubería de Gs en Pie Cúbico por Hora
[2013F, Ch 22, Tbl 26]
Longitud de Tubería, pie
10
20
30
40
50
60
70
80
90
100 125 150 175 200
0.364
32
22
18
15
14
12
11
11
10
9
8
8
7
6
0.493
72
49
40
34
30
27
25
23
22
21
18
17
15
14
0.622
132
92
73
63
56
50
46
43
40
38
34
31
28
26
0.824
278
190
152
130
115
105
96
90
84
79
72
64
59
55
1.049
520
350
285
245
215
195
180
170
160
150
130
120
110
100
1.380
1,050
730
590
500
440
400
370
350
320
305
275
250
225
210
1.610
1,600
1,100
890
760
670
610
560
530
490
460
410
380
350
320
2.067
3,050
2,100 1,650 1,450 1,270 1,150 1,050 990
930
870
780
710
650
610
2.469
4,800
3,300 2,700 2,300 2,000 1,850 1,700 1,600 1,500 1,400 1,250 1,130 1,050 980
3.068
8,500
5,900 4,700 4,100 3,600 3,250 3,000 2,800 2,600 2,500 2,200 2,000 1,850 1,700
4.026
17,500 12,000 9,700 8,300 7,400 6,800 6,200 5,800 5,400 5,100 4,500 4,100 3,800 3,500
Nota: La capacidad es en pie cúbico por hora a presiones de gas de 0.5 psig o menos y una presión de caída de 03 pulg.
de agua, gravedad específica = 0.60.
Propiedad literaria por la Asociación Americana de Gas y la Asociación Nacional de Protección de Incendio. Utilizado
por permiso del titular de los derechos del autor.
Tabla 18.1 (SI) Capacidad Máxima de Tubería de Gas en Pie Cúbico por Hora
[2013F, Ch 22, Tbl 26]
(A presiones de gas de 3.5 kPa sobre atm. O menos y una caída de presión de 75 Pa.
Densidad = 0.735 kg/m3)
Longitud de Tubería, m
20
30
40
50
60
70
80
90
100 125 150 175 200
8
9.25
0.19 0.13 0.11 0.09 0.08 0.07 0.07 0.06 0.06 0.06 0.05 0.05 0.19 0.13
10
12.52
0.43 0.29 0.24 0.20 0.18 0.16 0.15 0.14 0.13 0.12 0.12 0.11 0.43 0.29
15
15.80
0.79 0.54 0.44 0.37 0.33 0.30 0.28 0.26 0.24 0.23 0.22 0.21 0.79 0.54
20
20.93
1.65 1.13 0.91 0.78 0.69 0.63 0.58 0.54 0.50 0.47 0.45 0.43 1.65 1.13
25
26.14
2.95 2.03 1.63 1.40 1.24 1.12 1.03 0.96 0.90 0.85 0.81 0.77 2.95 2.03
32
35.05
6.4
4.4
3.5
3.0
2.7
2.4
2.2
2.1
1.9
1.8
1.7
1.7
6.4
4.4
40
40.89
9.6
6.6
5.3
4.5
4.0
3.6
3.3
3.1
2.9
2.8
2.6
2.5
9.6
6.6
50
52.50
18.4 12.7 10.2
8.7
7.7
7.0
6.4
6.0
5.6
5.3
5.0
4.8
18.4 12.7
65
62.71
29.3 20.2 16.2 13.9 12.3 11.1 10.2
9.5
8.9
8.4
8.0
7.7
29.3 20.2
80
77.93
51.9 35.7 28.6 24.5 21.7 19.7 18.1 16.8 15.8 14.9 14.2 13.5 51.9 35.7
100
102.26
105.8 72.7 58.4 50.0 44.3 40.1 36.9 34.4 32.2 30.4 28.9 27.6 105.8 72.7
Nota:La capacidad es en litros por segundo a presión de gas de 3.5 kPa (calibre) o menor y una caída de presión de 75
kPa; densidad = 0.735 kg/m3.
Derechos de autor por la Asociación Americana de Gas y la Asociación Nacional de Protección de Incendio. Utilizado
por permiso del titular.
362
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tamaño
de
Diámetro
Tubería
Interno,
de Acero
10
mm
Nominal,
mm
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
18.
18.fm Page 363 Thursday, March 3, 2016 12:59 PM
Grado No.
Gravedad API
Densidad, lb/gal
Valor Calorífico, Btu/gal
1
38 to 45
6.950 to 6.675
137,000 to 132,900
2
30 to 38
7.296 to 6.960
141,800 to 137,000
4
20 to 28
7.787 to 7.396
148,100 to 143,100
5L
17 to 22
7.940 to 7.686
150,000 to 146,800
5H
14 to 18
8.080 to 7.890
152,000 to 149,400
6
8 to 15
8.448 to 8.053
155,900 to 151,300
Tabla 18.2 (SI) Gravedad API Típica, Densidad y Valor Calorífico
de Grados Estándar de Aceite Combustible [2013F, Ch 28, Tbl 6]
Densidad, kg/m3
Valor Calorífico, GJ/m3
1
833 a 800
38.2 a 37.0
2
874 a 834
39.5 a 38.2
4
933 a 886
41.3 a 39.9
5L
951 a 921
41.8 a 40.9
5H
968 a 945
42.4 a 41.6
6
1012 a 965
43.5 a 42.2
Combustibles y Combustió
Grado No.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
363
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 18.2 (I-P) Gravedad API Típica, Densidad y Valor Calorífico
de Grados Estándar de Aceite Combustible [2013F, Ch 28, Tbl 6]
18.fm Page 364 Thursday, March 3, 2016 12:59 PM
Combustibles y Combustión
Los aceites combustibles para calefacción están ampliamente clasificados como aceites combustibles destilados (aceites más ligeros) o aceites combustibles residuales (aceites más pesados).
La ASTM ha establecido especificaciones para las propiedades del aceite combustible el cual subdivide los aceites en varios grados. Grades No. 1 y 2 son aceites combustibles destilados. Los
Grades 4.5 (ligero), 5 (Pesado) y 6 son aceites combustibles residuales. Las especificaciones para
los grados están basadas en las características requeridas de aceites combustibles para uso en diferentes tipos de quemadores. La especificación de la norma ANSI para aceites combustibles es
ASTM Norma D396-86.
Grado No. 1 es un destilado ligero destinado para quemadores tipo vaporización. Volatilidad
alta es esencial para la continua evaporación del aceite combustible con residuo mínimo.
Grado No. 2 es un destilado más pesado (Gravedad API) que el No. 1. Es usado principalmente con quemadores de atomización de presión (pistola) que rocía el aceite dentro de una
cámara de combustión. El vapor de aceite atomizado es mezclado con aire y arde. Este grado es
utilizado en la mayoría de quemadores domésticos y muchos quemadores comercial-industrial de
capacidad media.
Grado No. 4 es un combustible intermedio que es considerado ya sea un residuo ligero o un
destilado pesado. Proyectado para quemadores que atomizan aceites de la más alta viscosidad que
los quemadores domésticos puedan manejar, su margen de viscosidad permisible permite ser
bombeado y atomizado a temperaturas de almacenaje relativamente bajas.
Grado No. 5 (Ligero) es un combustible residuo de viscosidad intermedia para quemadores
que manejan combustible más viscoso que el No. 4 sin precalentamiento. El precalentamiento
puede ser necesario en algunos equipos para quemar y, en climas más fríos, para la manipulación.
Grado No. 5 (Pesado) es un combustible residuo más viscoso que el (Ligero) No. 5, pero
proyectado para propósitos similares. El precalentamiento es usualmente necesario para quemar y,
en climas más fríos, para manipulación.
Grado No. 6 algunas veces referido como Bunker C, es un aceite de alta viscosidad utilizado
sobre todo en calefacción industrial y comercial. Requiere precalentamiento en el tanque de almacenaje para permitir bombeo y precalentamiento adicional en el quemador para permitir atomización.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 18.1 (I-P) Viscosidad Aproximada de Aceites Combustibles [2013F, Ch 28, Fig 2]
364
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tipos de Aceites Combustibles
18.fm Page 365 Thursday, March 3, 2016 12:59 PM
Combustibles y Combustió
Viscosidad Aproximada de Aceites Combustibles [2013F, Ch 28, Fig 2]
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
365
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 18.1 (SI)
18.fm Page 366 Thursday, March 3, 2016 12:59 PM
Combustibles y Combustión
Los combustibles para motores fijos primarios son diesel y aceites de turbinas a gas, gases
naturales y gases de petróleo licuado. Otros combustibles incluyen gas de alcantarilla, gas fabricado y mezcla de gases. Gasolina y las series JP de combustibles de turbinas a gas son raramente
utilizados para motores fijos.
Las propiedades de los tres grados de aceites combustibles diesel (1-D, 2-D y 4-D) están indicadas en la Norma ASTM D 975.
Grado No. 2-D incluye la clase de aceites de gas destilado de más baja volatilidad. Estos
combustibles son utilizados en motores de alta velocidad con cargas relativamente altas y velocidades uniformes, o en motores que no requieren combustibles con la más alta volatilidad u otras
propiedades especificadas para el Grado N o. 1-D.
Grado No 4-D cubre la clase de destilados más viscosos y mezcla de estos destilados con
aceites combustibles residuales. Estos combustibles son utilizados en motores de velocidad baja y
media que involucran cargas sostenidas en velocidad esencialmente constante.
Especificaciones de propiedad y métodos de prueba para aceites combustible diesel Grado
No. 1-D, 2-D y 4-D, son esencialmente idénticos a las especificaciones de aceites combustibles de
Grado No 1, 2 y 4, respectivamente. Sin embargo, aceites combustible diesel tienen una especificación adicional para número de cetano, el cual mide la calidad de ignición e influye en la rugosidad de combustión. Los requisitos del número de cetano dependen del diseño del motor, tamaño
velocidad y variaciones de carga y condiciones de arranque y atmosféricas. Un incremento en el
número de cetano sobre valores actualmente requeridos no mejora el rendimiento del motor. De
esta manera, el número de cetano debe ser tan bajo como sea posible para asegurar la máxima disponibilidad de combustible. La Norma ASTM D 975 proporciona muchos métodos para estimar e
número de cetano de otras propiedades de aceite combustible.
La Norma ASTM D 2880 para aceites combustibles de turbinas a gas relaciona los grados de
aceite combustible de turbinas a gas a combustible y grados de aceite combustible diesel.
Tabla 18.3 Requisitos Aproximados de Aire para Combustión Estequiométrico
de Varios Combustibles [2013F, Ch 28, Tbl 10]
Combustibles líquidos
Combustible No. 1
Combustible No. 2
Combustible No. 5
Combustible No. 6
Combustibles gaseosos
Gas Natural
Butano
Propano
Aire Teórico Requerido para Combustión
lb/lb (kg/kg) combustible
9.6
11.2
10.3
6.2
11.2
lb/gal (Mg/m3) combustible
103 (12.34)
106 (12.70)
112 (13.42)
114 (13.66)
pie3/pie3 (m3/m3) combustible
9.6
31.1
24.0
366
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tipo de combustible
Combustibles Sólidos
Antracita
Semi-bituminoso
Bituminoso
Lignito
Coque
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tipos y Propiedades de Combustibles Líquidos para Motores
18.fm Page 367 Thursday, March 3, 2016 12:59 PM
Tipo de Combustible
12.1
13.9
14.1
11.2
17.2
11.2
9.9
11.4
11.6
12.5
14.2
9.2
8.4
9.6
9.8
10.5
12.1
7.8
7.3
8.4
8.5
9.1
10.6
6.8
15.0
16.5
12.3
13.6
10.5
11.6
9.1
10.1
18.2
20.2
21.0
15.1
16.8
17.5
12.9
14.4
15.0
11.3
12.6
13.0
Combustibles y Combustió
Combustibles Gaseosos
Gas Natural
Gas Propano (comercial)
Gas Butano (comercial)
Gas Mixto (gas de agua natural y carburado)
Gas de agua carburado
Gas de coque
Combustibles Líquidos
Aceite Combustible No. 1 y 2
Aceite Combustible No. 6
Combustibles Sólidos
Carbón Bituminoso
Antracita
Coque
Teórico o Porcentaje de CO2 a Valores de
Exceso de Aire Dado
Máximo
CO2, %
20%
40%
60%
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
367
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 18.4 Valores Máximos Aproximados de CO2 (Estequiométrico) Teórico
y Valores de CO2 de Varios Combustibles
con Porcentajes Diferentes de Exceso de Aire [2013F, Ch 28, Tbl 11]
18.fm Page 368 Thursday, March 3, 2016 12:59 PM
Velocidad
de
Bombeo,
gph
10
40
70
100
130
160
190
220
Longitud de Recorrido en Pie a una Elevación de Succión Máxima de 10 pies
25
50
75
100
125
150
175
200
250
300
1/2
1/2
1/2
1/2
1/2
3/4
3/4
3/4
1/2
1/2
1/2
3/4
3/4
3/4
3/4
1
1/2
1/2
3/4
3/4
3/4
3/4
1
1
1/2
1/2
3/4
3/4
1
1
1
1
1/2
1/2
3/4
3/4
1
1
1
1
1/2
3/4
3/4
1
1
1
1
1 1/4
1/2
3/4
3/4
1
1
1
1 1/4
1 1/4
3/4
3/4
1
1
1
1 1/4
1 1/4
1 1/4
3/4
3/4
1
1
1 1/4
1 1/4
1 1/4
1/4
1
1
1
1 1/4
1 1/4
1 1/4
2
2
Combustibles y Combustión
Tabla 18.5 (SI) Tamaño Nominal Recomendado para Líneas de Succión de Aceite
Combustible desde el Depósito a la Bomba (Grados Destilados No. 1 y No. 2)
[2013F, Ch 22, Tbl 28]
Nota: Los tamaños (en milímetros) son nominales.
368
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Velocidad Longitud de Recorrido en Metros a una Elevación de Succión Máxima de 9.0 kPa
de
Bombeo,
10
20
30
40
50
60
70
80
90
100
L/h
50
15
15
15
15
15
20
20
20
25
25
100
15
15
15
15
20
20
20
20
25
25
200
15
20
20
20
20
20
25
25
25
25
300
15
20
20
20
20
25
25
25
25
32
400
20
20
20
20
25
25
25
25
32
32
500
20
25
25
25
25
25
32
32
32
32
600
20
25
25
25
25
32
32
32
32
50
700
20
25
25
25
25
32
32
32
50
50
800
20
25
25
25
32
32
32
32
50
50
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 18.5 (I-P) Tamaño Nominal Recomendado para Líneas de Succión de Aceite
Combustible desde el Depósito a la Bomba (Grados Destilados No. 1 y No. 2)
[2013F, Ch 22, Tbl 28]
18.fm Page 369 Thursday, March 3, 2016 12:59 PM
Velocidad
de
Bombeo,
gph
10
40
70
100
130
160
190
220
Longitud de Recorrido en Pie a una Elevación de Succión Máxima de 15 pie
25
50
75
100
125
150
175
200
250
300
1 1/2
1 1/2
1 1/2
2
2
2
2
2 1/2
1 1/2
1 1/2
2
2
2
2
2 1/2
2 1/2
1 1/2
1 1/2
2
2
2 1/2
2 1/2
2 1/2
2 1/2
1 1/2
2
2
2 1/2
2 1/2
2 1/2
2 1/2
3
1 1/2
2
2
2 1/2
2 1/2
2 1/2
3
3
1 1/2
2 1/2
2 1/2
3
3
3
3
3
2
2 1/2
2 1/2
3
3
3
3
4
2
2 1/2
2 1/2
3
3
3
4
4
2 1/2
2 1/2
3
3
3
4
4
4
2½
3
3
3
4
4
4
4
Notas:
1. Tamaños de tuberías más pequeño de 1 pulg. IPS no son recomendados para uso con aceites combustibles de grado
residual.
2. Líneas de transporte de aceite combustible desde el puerto de descarga de la bomba a los quemadores y retorno del
tanque puede ser reducida en uno o dos tamaños, dependiendo de la longitud de la tubería y pérdidas de presión.
Notas:
1. Tamaños (en milímetros) son nominales.
2. Tamaños de tuberías más pequeñas de 25 mm ISO no son recomendadas para uso con aceites combustibles de grado
residual.
3. Líneas que conducen aceite combustible desde el puerto de descarga de la bomba a los quemadores y retorno del
tanque puede ser reducida por uno o dos tamaños, dependiendo en la longitud de la tubería y pérdidas de presión.
369
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Velocidad Longitud de Recorrido en Metros a una Elevación de Succión Máxima de 4.5 kPa
de
Bombeo,
10
20
30
40
50
60
70
80
90
100
L/h
50
40
40
40
50
50
50
65
65
65
80
100
40
40
50
50
65
65
65
65
80
80
200
40
50
50
50
65
65
65
80
80
80
300
50
50
65
65
65
80
80
80
80
80
400
50
50
65
65
80
80
80
80
80
100
500
50
65
65
65
80
80
80
80
100
100
600
65
65
65
80
80
80
100
100
100
100
700
65
65
65
80
80
100
100
100
100
100
800
65
65
80
80
100
100
100
100
100
100
Combustibles y Combustió
Tabla 18.6 (SI) Tamaño Nominal Recomendado para Líneas de Succión de Aceite
Combustible desde el Depósito a la Bomba (Grados Residuales No. 5 y No. 6)
[2013F, Ch 22, Tbl 27]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 18.6 (I-P) Tamaño Nominal Recomendado para Líneas de Succión de Aceite
Combustible desde el Depósito a la Bomba (Grados Residuales No. 5 y No. 6)
[2013F, Ch 22, Tbl 27]
19.fm Page 370 Thursday, March 3, 2016 1:00 PM
POSESIÓN Y OPERACIÓN
El costo de mantenimiento de los sistemas mecánicos varía ampliamente dependiendo de la
configuración, ubicación de los equipos, accesibilidad, complejidad del sistema, función de servicio, geografía y requisitos de confiabilidad del sistema.
Dohrmann y Alereza (1986) obtuvieron costos e información del sistema HVAC de 342 edificios situados en 35 estados en los Estados Unidos. En 1983 dólares de Estados Unidos, los datos recogidos mostraron un costo medio de mantenimiento del sistema HVAC de $0.30/pie2 ($3.40/m2) por
año, con un costo mediano de $0.24/pie2 ($2.60/m2) por año. La antigüedad del inmueble tiene un
significante estadísticamente, pero menos efecto en costos de mantenimiento de HVAC. Análisis
también indicaron que el tamaño del inmueble no es estadísticamente significante en la explicación
de variación de costos. El tipo de programa de mantenimiento o agencia de servicio que la dirección
del edificio elija puede también tener un efecto significante en los costos totales de mantenimiento
de HVAC. Aunque una rutina minuciosa o extensiva y programas de mantenimiento preventivo
cuestan más de administrar, generalmente extienden la vida del equipo; mejoran la confiabilidad y
reducen el tiempo de inactividad del sistema, costos de energía y los costos globales del ciclo de
vida.
Algunos datos de costo de mantenimiento están disponibles, ambos en el dominio público y
de fuentes propias utilizados por varios proveedores de servicios comerciales. Estas fuentes
pueden incluir fabricantes de equipos, proveedores de servicios independientes, aseguradores,
agencias gubernamentales (ej. la Administración de Servicios Generales de los Estados Unidos) y
organizaciones relacionadas a la industria [ej. los Propietarios de Edificios y Asociación de Directores (BOMA) y publicaciones de la industria de servicios. Más tradicional, productos utilizados
ampliamente y componentes son probables de tener estadísticamente registros confiables. Sin
embargo, cambios de diseño o modificaciones necesitados por cambios en la industria, como
refrigerantes alternativos, pueden hacer los datos históricos menos relevantes.
Productos HVAC nuevos, componentes, configuraciones del sistema, sistemas de control y
protocolos, y aplicaciones de sistemas revisados o actualizados presentan un reto adicional.
Cuidado es requerido cuando se utiliza datos no extraídos de amplia experiencia o reportes de
campo. En muchos casos, la información de mantenimiento es patentada o fue patrocinado por
una entidad o grupo particular. Cuidado especial debe tomarse cuando se utiliza estos datos. Es de
responsabilidad del usuario obtener estos datos y determinar sus propiedades y conveniencia para
la aplicación que está siendo considerada.
El proyecto de investigación TRP-1237 (Abramson et al. 2005) de ASHRAE reveló una
herramienta estandarizada de recolección de datos basado en internet y base de datos sobre
vida de servicio de equipos HVAC y costos de mantenimiento. La base de datos fue sembrada
con datos en 163 edificios alrededor del país. Los datos de costo de mantenimiento fueron
reunidos para costos totales de mantenimiento del sistema HVAC de 100 instalaciones. En
2004 dólares, el costo de mantenimiento promedio de HVAC de estos datos fue $0.74/pie2
($5.06/m2) y el costo medio fue $0.44/pie2 ($4.74/m2). La Tabla 19.1 compara estas figuras
con estimaciones reportadas por Dohrmann y Alereza (1986), ambos en términos de dólares
contemporáneos y en 2004 dólares y muestran que el costo por pie cuadrado (metro) varía
ampliamente entre estudios.
Costos de Mantenimiento Estimados
Los costos totales de mantenimiento de HVAC para edificios existentes y nuevos con
varios tipos de equipos pueden ser estimados en varias maneras, utilizando varios recursos.
Los requisitos de mantenimiento de equipos pueden ser obtenidos de los fabricantes de equipos para grandes o personalizadas piezas de equipos. Estimar las necesidades de trabajo en
casa puede ser difícil, los Propietarios de Edificios y Asociación de Directores (BOMA) provee orientación sobre este tópico. Muchas compañías de servicio mecánico independientes
ofrecen contratos de mantenimiento preventivo. Estas compañías típicamente tienen programas de estimación de propiedad desarrollados a través de su experiencia, y a menudo proporcionan costos de mantenimiento generalizado a ingenieros y propietarios a pedido, sin
obligación.
370
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Posesión y Operación
Costos de Mantenimiento
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
19.
19.fm Page 371 Thursday, March 3, 2016 1:00 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 19.1
Comparación de Costos de Mantenimiento Entre los Estudios
[2011A, Ch 37, Tbl 6]
Costo por pie2 (m2),
Como Reportado Consumidor
Índice de
Precios
Media
Mediana
Costo por pie2 (m2),
2004 Dólares
Media
Mediana
Dohrmann y Alereza (1986)
$0.32
($3.44)
$0.24
($2.58)
99.6
$0.61
($6.57)
$0.46
($4.95)
Abramson et al. (2005)
$0.47
($5.06)
$0.44
($4.74)
188.9
$0.47
($5.06)
$0.44
($4.74)
Encuesta
Cuando se evalúan varios sistemas HVAC durante diseño o modificación, la magnitud absoluta de costos de mantenimiento no debe ser tan importante como los costos relativos. Cualquier
método de estimación o recurso sea seleccionado, debe ser utilizado consistentemente a través de
cualquier evaluación. Información mezclada de recursos diferentes en una evaluación puede suministrar resultados erróneos.
Aplicando costos simples por unidad de área de piso del edificio para mantenimiento es altamente desalentador. Los costos de mantenimiento pueden ser generalizados por tipos de sistemas.
Cuando se proyecten costos de mantenimiento para sistemas diferentes de HVAC, los componentes grandes del sistema necesitan ser identificados con un nivel requerido de mantenimiento. Los
costos potenciales a largo plazo de cuestiones ambientales en costos de mantenimiento también
deben ser considerados.
Posesión y Operación
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
371
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
19.fm Page 372 Thursday, March 3, 2016 1:00 PM
Resumen y Datos de Costo de Operación y Posesión
[2011A, Ch 37, Tbl 1]
COSTOS DE POSESIÓN
I.
Costo Inicial del Sistema
II.
Costos Periódicos
_______
A. Impuesto sobre la Renta
_______
B.
Impuestos Prediales
_______
C.
Seguro
_______
D. Renta
E.
_______
Otros Costos Periódicos
_______
Total Costos Periódicos
_______
III. Costos de Reposición
_______
IV. Valor de Recuperación
_______
Costos Totales de Posesión
_______
COSTOS DE OPERACIÓN
V.
Costos Anuales de Servicios Públicos, combustible, agua, etc.
A. Servicios Públicos
Electricidad
_______
2.
Gas Natural
_______
3.
Agua/desagüe
_______
4.
Vapor comprado
_______
5.
Agua fría/caliente comprada
_______
Combustibles
1.
Propano
_______
2.
Aceite combustible
_______
3.
Diesel
_______
4.
Carbón
_______
C.
Generación de electricidad en el sitio
D.
Otros costos de servicio público, combustible, agua,
_______
etc.
Total
_______
_______
VI. Asignaciones Mantenimiento Anual/Costos
A. Trabajo en casa
_______
B.
Servicio de Mantenimiento Contratado
_______
C.
Materiales en casa
_______
Otras asignaciones de mantenimiento/costos
D.
(ej. tratamiento de agua)
Total
_______
_______
VII. Costos de Administración Anual
_______
Costos Totales Anuales de Operación
COSTOS TOTALES ANUALES DE OPERACIÓN Y POSESIÓN
_______
_______
372
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Posesión y Operación
B.
1.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 19.2
19.fm Page 373 Thursday, March 3, 2016 1:00 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Recuperación Simple
Esto ignora la inflación y el valor temporal del dinero. Los ahorros de la corriente de costos
de ingreso anual y otros factores son estimados y divididos en el desembolso del capital inicial; el
resultado es el tiempo de recuperación simple en años.
Costos del Ciclo de Vida
Una representación en dólares actuales del costo de una inversión sobre su tiempo de vida es
útil para evaluar mutuamente alternativas exclusivas que tienen el mismo tiempo de vida esperado.
Una tasa de descuento es necesaria para un cálculo del costo de ciclo de vida. La tasa de descuento representa el costo del capital a los propietarios de edificios. En esencia, es la tasa sobre un
préstamo (u obligación) ajustado a la cuenta por inflación e impuestos. Un 3% real de tasa de descuento es típica para análisis de política energética. Tasas más altas son a menudo utilizadas por
inversionistas privados para la evaluación económica de construcción comercial. Para explicar
inflación y subida de combustible, o baja la tasa de descuento o infla la energía futura y los costos
de mantenimiento.
El costo de ciclo de vida es calculado determinando el valor actual del costo de una inversión.
Para sistemas alternativos, esto es
LCC = IC + ESPWF (COSTOenergía + COSTOmant.)
donde
LCC
= costo de ciclo de vida
IC
= costo inicial de prima de alternativa
ESPWF
= factor de valor actual de series iguales
COSTOenergía = ahorro de costo de energía anual
= reducción de costo de mantenimiento anual
COSTOmant
ESPWF para otros tiempos de vida y tasas de descuento puede ser calculado de
n
1 + d  – 1
ESPWF = ----------------------------n
d 1 + d 
Los pagos iguales futuros para reembolsar un valor actual de dinero están determinados por el
factor de recuperación de capital, que es lo recíproco del factor del valor actual para una serie de
pagos iguales.
i
i  1 + i  n - = -------------------------CRF = -------------------------n
n
1 + i – 1
1 – 1 + i
Análisis de Recuperación Mejorada
Similar a la recuperación simple pero el costo del dinero es considerado
ln  CRF/[i – CRF] -
n = ---------------------------------------------ln  1 + i 
373
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Posesión y Operación
Factores de Recuperación de Capital
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
donde n = tiempo de vida en años y d = tasa de descuento en porcentaje/100.
Tenga en cuenta que ESPWF puede ser usada solamente cuando los costos anuales permanecen constantes.
19.fm Page 374 Thursday, March 3, 2016 1:00 PM
7
10
15
Factores de Valores Actuales
Tasa de Descuento
2.5%
6.35
8.75
12.38
3.0%
6.23
8.53
11.94
3.5%
6.11
8.32
11.52
4.0%
6.00
8.11
11.12
4.5%
5.89
7.91
10.74
7%
5.39
7.02
9.11
10%
4.8
6.14
7.61
15%
4.16
5.02
5.85
Tabla 19.4 Factores de Recuperación de Capital Anual [2003A, Ch 36, Tbl 5]
Tasa de Rendimiento o Tasa de Interés, % por Año
Años
4.5
6
8
10
2
0.526 40
0.534 00
0.545 44
0.560 77
0.576 19
4
0.272 25
0.278 74
0.288 59
0.301 92
0.315 47
6
0.187 67
0.193 88
0.203 36
0.216 32
0.229 61
8
0.145 48
0.151 61
0.161 04
0.174 01
0.187 44
10
0.120 24
0.126 38
0.135 87
0.149 03
0.162 75
12
0.103 48
0.109 67
0.119 28
0.132 70
0.146 76
14
0.091 57
0.097 82
0.107 58
0.121 30
0.135 75
16
0.082 68
0.089 02
0.098 95
0.112 98
0.127 82
18
0.075 82
0.082 24
0.092 36
0.106 70
0.121 93
Figure 19.1 Factor de Recuperacion de Capital [2003A, Ch 36, Fig 1]
374
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Posesión y Operación
3.5
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 19.3
Tiempo de Vida
(años)
20.fm Page 375 Thursday, March 3, 2016 2:15 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
20.
ACUSTICA
Presión Acústica y Nivel de Presión Acústica
La intensidad acústica es difícil de medir directamente, pero la presión acústica es relativamente fácil de medir; el oído humano y micrófonos son dispositivos sensibles a la presión. Una
escala de decibelios para presión acústica puede ser creada en una manera análoga a la escala de
decibelios para la intensidad acústica, con una presión de referencia de20 µPa, lo que corresponde
al umbral de audibilidad aproximado. Como la presión al cuadrado es proporcional a la intensidad, el nivel de presión acústica es
Lp = 10 log(p/pref )2 re pref
Ya que p/pref es 20 Pa, que es 2  10−5 Pa, y ya que 10 logp2 = 20 logp,
Lp = 20 log(p/2  10–5) re 20 Pa
donde p es el valor de la media cuadrática (rms) de presión en micropascales . O
Lp = 20 log p + 94 db re 20 Pa
El oído humano responde a través de una amplia gama de presiones acústicas. La escala de
alcance lineal para presión acústica en la Tabla 20.1 es difícil en esta forma; por consiguiente, las
anotaciones logarítmicas equivalentes deberán ser utilizadas.
Tabla 20.1 Presiones Acústicas Típicas y Niveles de Presiones Acústicas
[2013F, Ch 8, Tbl 1]
Fuente
Presión
Acústica,
Pa
Reacción
Subjetiva
Peligro extremo
Despegue de je militar a 100 pie (30 m)
200
140
Fuego de artillería a 10 pie (3 m)
63.2
130
Despegue de jet de pasajeros a 50 pie (15 m)
20
120
Umbral de dolor
Banda de rock volumen alto
6.3
110
Umbral de malestar
Bocina de automóvil a 10 pie (3 m)
2
100
Motor a diesel grande sin escape a 130 pie (40 m)
0.6
90
Acelerar camión diesel en 50 pie (15 m)
0.2
80
Tren de carga en 100 pie (30 m)
0.06
70
Discurso en 3 pie (1 m)
0.02
60
Acondicionador de aire de ventana en 3 pie (3 m)
0.006
50
Área residencial tranquila
0.002
40
Conversación en secreto en 6 pie (2 m)
0.0006
30
Zumbido de insecto en 3 pie (1 m)
0.0002
20
Umbral de buena audición
0.00006
10
Débil
Umbral de excelente audición juvenil
0.00002
0
Umbral de audición
Muy alto
Moderado
Acustica
375
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nivel de
Presión
Acústica,
dB re 20
Pa
20.fm Page 376 Thursday, March 3, 2016 2:15 PM
Para estimar los niveles de múltiples fuentes de los niveles de cada fuente, las intensidades
(no los niveles) deben ser agregados. De esta manera, los niveles deben ser primero convertidos
para encontrar las intensidades, las intensidades sumadas y entonces convertidas de nuevo a un
nivel, de esta manera la combinación de múltiples niveles L1, L2, etc., producen un nivel Lsuma
dado por
L sum = 10 log
L  10
i 10 i
L  10
2
2
Donde para nivel de presión acústica (Lp) 10 i
es p i  p ref , y Li es el nivel de presión
acústica para la fuente i th.
Un método más simple y ligeramente menos preciso está descrito en la Tabla 20.2 Este método, aunque no es exacto, resulta en error de 1 dB o menos. El proceso con una serie de niveles
puede ser acortado combinando la más grande con la siguiente más grande, después la cuarta más
grande y así sucesivamente hasta que la combinación de los niveles restantes es 10 dB más bajo
que el nivel combinado. El proceso puede ser entonces parado.
Potencia Acústica y Nivel de Potencia Acústica
Una característica fundamental de una fuente acústica es su habilidad de radiar energía. Algunas entradas de energía excitan la fuente, que irradia alguna fracción de esta energía en la forma
de acústica. Debido a que la potencia de la unidad radiada a través de una esfera de unidad produce la intensidad de la unidad, la base de referencia de la potencia, establecida por acuerdos
internacionales, es 1 picovatio (pW) (1012 W). La cantidad de referencia utilizada será declarada
explícitamente. Una definición de nivel de potencia acústica es, por consiguiente
Lw = logw/(10–12W) dB re 1 pW
Tabla 20.2
o
Lw = 10 logw + 120 dB re 1 pW
Combinación de Dos Niveles de Acústica [2013F, Ch 8, Tbl 3]
2a4
5a9
10 y más
3
2
1
0
Acustica
0a1
Número de decibeles a agregar a niveles más altos para
obtener nivel combinado
Figura 20.1 Curvas que Muestran Respuestas de Ponderación para Sonómetros
[2013F, Ch 8, Fig 1]
376
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Diferencia entre niveles a ser combinados, dB
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Combinación de Niveles Acústicos
20.fm Page 377 Thursday, March 3, 2016 2:15 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 20.3 Banda Media y Frecuencias Aproximadas de Corte Superior e Inferior
para Octavas y 1/3 de Octava de Filtros de Banda [2013F, Ch 8, Tbl 4]
Bandas de Octava, Hz,
I-P (SI)
Inferior
11.2 (11.2)
22.4 (22.4)
45 (45)
90 (90)
180 (180)
355 (355)
1,400 (1 400)
2,800 (2 800)
31.5 (31.5)
63 (63)
125 (125)
250 (250)
500 (500)
1,000 (1 000)
2,000 (2 000)
4,000 (4 000)
22.4 (22.4)
45 (45)
90 (90)
180 (180)
355 (355)
710 (710)
1,400 (1 400)
2,800 (2 800)
5,600 (5 600)
8,000 (8 000) 11,200 (11 200)
Inferior
Banda Media
Superior
11.2 (11.2)
12.5 (12.5)
14 (14)
14 (14)
16 (16)
18 (18)
18 (18)
20 (20)
22.4 (22.4)
22.4 (22.4)
25 (25)
28 (28)
28 (28)
31.5 (31.5)
35.5 (35.5)
35.5 (35.5)
40 (40)
45 (45)
45 (45)
50 (50)
56 (56)
56 (56)
63 (63)
71 (71)
71 (71)
80 (80)
90 (90)
112 (112)
90 (90)
100 (100)
112 (112)
125 (125)
140 (140)
140 (140)
160 (160)
180 (180)
180 (180)
200 (200)
224 (224)
224 (224)
250 (250)
280 (280)
280 (280)
315 (315)
355 (355)
355 (355)
400 (400)
450 (450)
450 (450)
500 (500)
560 (560)
560 (560)
630 (630)
710 (710)
710 (710)
800 (800)
900 (900)
900 (900)
1,000 (1 000)
1,120 (1 120)
1,120 (1 120)
1,250 (1 250)
1,400 (1 400)
1,400 (1 400)
1,600 (1 600)
1,800 (1 800)
1,800 (1 800)
2,000 (2 000)
2,240 (2 240)
2,240 (2 240)
2,500 (2 500)
2,800 (2 800)
2,800 (2 800)
3,150 (3 150)
3,550 (3 550)
3,550 (3 550)
4,000 (4 000)
4,500 (4 500)
4,500 (4 500)
5,000 (5 000)
5,600 (5 600)
5,600 (5 600)
6,300 (6 300)
7,100 (7 100)
7,100 (7 100)
8,000 (8 000)
9,000 (9 000)
9,000 (9 000) 10,000 (10 000)11,200 (11 200)
11,200 (11 200)12,500 (12 500)14,000 (14 000)
11,200 (11 200)16,000 (16 000)22,400 (22 400) 14,000 (14 000)16,000 (16 000)18,000 (18 000)
18,000 (18 000)20,000 (20 000)22,400 (22 400)
377
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Acustica
5,600 (5 600)
16 (16)
Superior
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
710 (710)
Banda Meda
Bandas 1/3 de Octava, Hz
I-P (SI)
20.fm Page 378 Thursday, March 3, 2016 2:15 PM
Salas de conferencia grandes sin amplificación de
voz
Acustica
Bibliotecas
Gimnasios, Estadios
Interiores
Gimnasios y piscinasg
Espacios con grandes capacidades de asientos
con amplificador de vozg
25
30
55
30
45
35
50
60
70
50
55
75
N/A
= No applicable
a Valores y márgenes están basados en juicios y experiencias y representan líneas generales de aceptabilidad para
ocupaciones típicas de construcción. .
b NC: estas parcelas métricas de niveles de sonido de banda de octava contra una familia de curvas de referencia, con
la capacidad del número igual al valor de la línea de tangente más alta.
RC: cuando la calidad del sonido en el espacio es importante, el RC métrico provee una herramienta de diagnóstico
para cuantificar ambos el nivel de interferencia del habla y desbalance espectral.
c dBA y dBC: estas son mediciones de nivel de presión de sonido en general con valoración A y C y sirven como
buenas referencias para una medición rápida de un solo número. Ellas también son apropiadas para especificación
en casos donde datos de sonido de banda octava no están disponibles para diseño.
d Ruido intrusivo está dirigido aquí para uso en la evaluación de un posible no HVAC ruido que es probable de contribuir a los niveles de ruido de fondo.
e Un consultor acústico experimentado debe mantenerse para consultor sobre espacios acústicos críticos (bajo RC30) y para todos los espacios de artes escénicas.
f Algunos educadores y otros creen que criterios de sonido relacionados con HVAC para escuelas, como enumerados
en ediciones previas de esta tabla, son muy altos e impiden el aprendizaje para grupos afectados de todas las
edades. Ver ANSI/ASA, Norma S12 60 (ASA 2009, 2010) para acústicas de salas de clases y una justificación para
bajar el criterio de sonido en las escuelas. Los componentes de HVAC de ruido total reúnen los requisitos de fondo
de esa norma si lOS antecedentes relacionadas de HVAC suenan aproximadamente NC/RC 25. Dentro de esta categoría, diseños para escuelas K-8 deben ser más silenciosos que aquellos para escuelas secundarias y colegios.
g RC ó NC criterios para estos espacios necesitan solamente ser seleccionados para el habla deseada y condiciones auditivas.
378
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Análisis Nivel de Presión
Banda de Acústica Total
Octavaa Aproximadaa
NC/RCb dBAc dBCc
Habitaciones con intrusión Ruido de Tráfico
N/A
45
70
de fuentes de ruido exteriordSobrevuelos de Aeronaves
N/A
45
70
Residencias, Apartamentos, Áreas de Vivienda
30
35
60
Condominios
Baños, cocinas, cuartos de servicio
35
40
60
Hoteles/Moteles
Habitaciones Individuales o suites
30
35
60
Cuartos de reunión/banquetes
30
35
60
Pasillos y vestíbulos
40
45
65
Áreas de servicio/soporte
40
45
65
Edificios de oficina
Oficinas ejecutivas y privadas
30
35
60
Salas de conferencia
30
35
60
Salas de teleconferencia
25
30
55
Oficinas abiertas
40
45
65
Pasillos y vestíbulos
40
45
65
Salas de Audiencia
Discurso sin amplificador
30
35
60
Discurso con amplificador
35
40
60
Espacios para Artes
Teatros dramáticos, concierto y salas de recitales
20
25
50
Escénicas
Estudios de enseñanza de música
25
30
55
Salones para práctica de música
30
35
60
Hospitales y Clínicas
Habitaciones de pacientes
30
35
60
Salas
35
40
60
Salas de operaciones y procedimientos
35
40
60
Pasillos y vestíbulos
40
45
65
Laboratorios
Prueba/investigación con comunicación de
50
55
75
expresión mínima
Uso de teléfono extensivo y comunicación de voz
45
50
70
Enseñanza en grupo
35
40
60
Iglesias, Mezquitas,
Asamblea general con programas de música
25
30
55
Sinagogas
críticose
Escuelasf
Salas de Clase
30
35
60
Salas de conferencia grandes con amplificación
30
35
60
de voz
Tipos de Habitación
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 20.4 Pautas de Diseño para Calefacción, Ventilación y Aire Acondicionado
(HVAC)-Sonidos de Fondo Relacionados en Habitaciones [2011A, Ch 48, Tbl 1]
20.fm Page 379 Thursday, March 3, 2016 2:15 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 20.5 Comparación de Métodos de Evaluación Acústica [2011A, Ch 48, Tbl 4]
Método
Resumen
Considera
Evalúa la
Efectos de
Calidad del
Interferencia
Sonido
del Habla
Componentes
Actualmente
Especificados por
cada Método
Torres de enfriamiento
Enfriadores de agua
Unidades de
condensación
dBA
Ninguna evaluación de calidad
Frecuentemente utilizada para
ordenanzas de ruido exterior
Sí
No
NC
Puede evaluar componentes
Evaluación de calidad limitada
No evalúa ruido de frecuencia baja
Sí
Algo
Difusores de
Terminales de aire
Sí
Sí
No utilizado para
componente de
evaluación
Sí
Algo
Ver NC
Algo
No utilizado para
componente de
evaluación
RC
Mark II
NCB
RNC
Utilizado para evaluar sistemas
No debe utilizarse para evaluar
componentes
Evalúa calidad de sonido
Proporciona capacidad de
diagnóstico mejorado
Puede evaluar componentes
Alguna evaluación de calidad
Alguna evaluación de calidad
Intenta cuantificar las
fluctuaciones
Sí
Acustica
379
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 20.2 Curvas de Criterios de Ruido (NC) y Espectro Típico (Curva con Símbolos)
[2013F, Ch 8, Fig 7]
20.fm Page 380 Thursday, March 3, 2016 2:15 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Acustica
Figura 20.4 Trayectorias Típicas de Ruido y Propagación de Vibración en Sistemas HVAC
[2011A, Ch 48, Fig 1]
380
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 20.3 Curvas Criterios de Habitaciones, Mark II [2011A, Ch 48, Fig 6]
20.fm Page 381 Thursday, March 3, 2016 2:15 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 20.5 (I-P) Comparación de Dispersor de 5 pie y Rendimiento de Silenciador Reactivo —
Revestimiento de Película para Ajustarse a la Norma NFPA 90A [2011A, Ch 48, Fig 23]
Acustica
381
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 20.5 (SI) Comparación de Dispersor de 1.5 m y Rendimiento de Silenciador Reactivo —
Revestimiento de Película para Ajustarse a la Norma NFPA 90A [2011A, Ch 48, Fig 23]
20.fm Page 382 Thursday, March 3, 2016 2:15 PM
Acustica
Un número de normas de acústica AHRI, AMCA, CTI y ANSI son utilizadas por fabricantes
de equipos para proveer datos de acústica precisos. Datos suministrados por fabricantes de acuerdo con la norma apropiada deben ser utilizados de preferencia a cualquier información empírica
anterior en la evaluación del ruido resultante de un elemento de equipo en particular.
382
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 20.7 Frecuencias en la cual Diferentes Tipos de Equipo Mecánico Generalmente
Controlan Espectros Acústicos [2011A, Ch 48, Fig 4]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Figura 20.6 Varias Configuraciones de Salida para Ventiladores Centrífugos y
Sus Posibles Condiciones de Ruido [2011A, Ch 48, Fig 25]
20.fm Page 383 Thursday, March 3, 2016 2:15 PM
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 20.6 Clase de Transmisión Acústica (STC) y Valores de Pérdidas de
Transmisión de Equipo Mecánico Típico de Pared de Habitación, Piso y
Tipos de Tumbados, dB [2011A, Ch 48, Tbl 40]
Tipo de Construcción de Habitación
STC
8 pulg. (200 mm) CMU*
8 pulg. (200 mm) CMU con 5/8 puñg. (16 mm)
GWB* en listones de enrasar
5/8 pulg. (16 mm) GWB en ambos lados de 3 5/8
pul. (92 mm) tornillos de metal
5/8 piñh. (16 mm) GWB en ambos lados de 3 5/8
pul. (92 mm) tornillos de metal con aislamiento
de fibra de vidrio en la cavidad
2 capas de 5/8 pulg. (16 mm) GWB en ambos
lados de 3 5/8 pul. (92 mm ) tornillos de metal
con aislamiento de fibra de vidrio en la cavidad
Doble fila de 3 5/8 puñ. (92 mm) tornillos de
metal, 1 pul. (25 mm) aparte, cada uno con 2
capas de 5/8 pul. (16 mm) GWB y aislamiento de
fibra de vidrio en la cavidad
6 pul. (150 mm) concreto sólido piso/tumbado
6 pul. (150 mm) con piso de concreto sólido 4
pul. (100 mm) losa de concreto aislada y
aislamiento de fibra de vidrio en la cavidad
6 pul. (150 mm) piso de concreto sólido con dos
capas de 5/8 pul. (16 mm) GWB colgado en
aisladores de muelle con aislamiento de fibra de
vidrio en la cavidad
50
Octava de Frecuencia a Mitad de
Banda, Hz
63 125 250 500 1000 2000 4000
35 35 41 44 50
57 64
53
33
32
44
50
56
59
65
38
18
16
33
47
55
43
47
49
16
23
44
58
64
52
53
56
19
32
50
62
67
58
63
64
23
40
54
62
71
69
74
53
40
40
40
49
58
67
76
72
44
52
58
73
87
97 100
84
53
63
70
84
93
104 105
Acustica
383
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota: La composición del material actual (ej. densidad, porosidad, rigidez), afecta la pérdida de transmisión en los
valores de la Clase de Transmisión Acústica (STC).
*CMU = unidad de mampostería de concreto, GWB = paneles de yeso.
20.fm Page 384 Thursday, March 3, 2016 2:15 PM
Fuente Acústica
Vía No.
Ventiladores de circulación, rejillas, registros, difusores, equipo unitario en
1
habitación
Bobina de inducción y unidades mezcladoras de ventilador accionado por volumen
1, 2
de aire variable (VAV)
Equipo unitario situado fuera de habitación servida; equipo de tratamiento de aire
remotamente ubicado, como ventiladores, sopladores, amortiguadores, accesorios de
2, 3
conductos y depuradores de aire.
Compresores, bombas y otros equipos de rotación y reciprocidad (excluyendo
4, 5, 6
equipo de tratamiento de aire)
Torres de enfriamiento; condensadores enfriados por aire
4, 5, 6, 7
Extractores de aire, acondicionadores de aire de ventana
7, 8
Transmisor acústico entre habitaciones
9, 10
No.
Vías de Transmisión
Métodos de Reducción de Ruido
1 Sonido directo irradiado de la fuente de El sonido directo puede ser controlado solo por la
sonido al oído
selección de equipo silencioso.
Sonido reflejado de paredes, techo y Sonido reflejado es controlado agregando la
piso
absorción acústica a la habitación y a la ubicación
del equipo.
2 Aire y sonido propagado por
Conducto de diseño y accesorios para turbulencia
estructuras sólidas radiadas con
baja, ubicar conductos de alta velocidad en áreas no
cubiertas y a través de paredes de
críticas; aislar los conductos y plenos acústicos en
conductos y plenos es transmitido a
conductos de suministro y aire de retorno
través de paredes y techos en la
habitación
3 Sonido aéreo radiado a través de
Seleccionar ventiladores para potencia acústica
conductos de suministro y aire de
mínima, utilizar conductos alineados con material
retorno a los difusores en la habitación absorbente de sonido, utilice silenciadores de
y luego al oyente por la Vía 1
conductos o plenos acústicos en conductos de
suministro y aire de retorno.
4 Ruido transmitido a través del equipo Ubicar equipos de habitaciones lejos de áreas
de las paredes de la habitación y pisos a críticas, utilice bloques de mampostería o concreto
habitaciones adyacentes
para equipos de paredes de habitación y piso.
5 Vibración transmitida a través de la
Instalar todas las maquinarias sobre aisladores de
estructura del edificio a las paredes y vibración adecuadamente diseñados, diseñar
techos adyacentes, desde la cual irradia habitación de equipo mecánico para cargas
como ruido dentro de la habitación por dinámicas, rotación balanceada y equipo
la Vía 1 1
alternativo.
6 Transmisión de vibración a lo largo de Aislar la tubería y conductos de la estructura con
las tuberías y paredes del conducto
neopreno o soportes de suspensión, instalar los
conectores flexibles entre tuberías, conductos y
máquinas vibradoras.
7 Ruido radiado al exterior de las
Instalar equipo lejos de las zonas críticas, utilice
ventanas de la habitación
barreras y cubiertas para interruptor las vías de
ruido, seleccione equipo silencioso.
8 Ruido interior sigue la Vía 1
Seleccione equipo silencioso.
9 Ruido transmitido a un difusor de aire Diseñe e instale conductos de atenuación para que
en una habitación, en un conducto y
coincida con la pérdida de transmisión de la pared
afuera a través de un difusor de aire en entre las habitaciones.
otra habitación
10 Transmisión de sonido a través, encima Extender la partición a la losa de techo y sellar
y alrededor de participación de
herméticamente, sellar toda la tubería, conductos,
habitación
ductos y otras penetraciones de partición.,
384
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Acustica
Fuentes Acústicas, Vías de Transmisión y Métodos de Reducción
de Ruido Recomendados [2011A, Ch 48, Tbl 6]
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Tabla 20.7
21.fm Page 385 Thursday, March 3, 2016 1:49 PM
VIBRACION
Donde k es la rigidez del aislador de vibración (fuerza por unidad de deflexión) y M es l masa dsel
equipo apoyado por el aislador.
3.13
f n = ----------- Hz
 st
donde  st es la deflexión estática del aislador en pulgadas.
Transmisibilidad es la relación de las amplitudes de la fuerza transmitida a la estructura del
edificio a la fuerza excitante producida por el equipo de vibración. Transmisibilidad es inversamente proporcional al cuadrado de la frecuencia perturbadora, fd, a la frecuencia natural, fn.
1
T = ---------------------------------1 –  f d  f n 2
en fd = fn ocurre la resonancia. El aislamiento de vibración es efectivo sólo en una relación a fd/fn > 3.5.
Cuando la rigidez de la estructura de soporte no es grande con respecto a la rigidez del aislador, se convierte en un sistema de libertados de dos grados. En este caso, elija un aislador que proporcionará deflexión estática ocho a diez veces que la de la deflexión estática de piso estimada
debido al peso agregado del equipo. Apoyo sísmico debe ser incluido en o con los aisladores para
limitar el movimiento del equipo.
Figura 21.2 Sistema de Libertad de Dos Grados [2013F, Ch 8, Fig 11]
385
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Figura 21.1 Sistema de Libertad de un solo Grado [2013F, Ch 8, Fig 8]
Vibracion
1 k
Frecuencia Natural, f n = ------ ----2 M
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
21.
Sistemas de bomba de empaquetado
Succión final y succión doble/caja dividida
En línea
Tanque montado vertical
Montado en la base
Alternativo grande
Bombas
Acoplado cerrado
Máquinas de Refrigeración y Enfriadores
Alternativo
Centrífugo, espiral
Tornillo
Absorción
Alternativo enfriado por aire, espiral
Tornillo refrigerado por aire
Compresores de Aire y Bombas de Vacío
Tanque montado horizontal
Tipo de Equipo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
10
15
Todo
Todo
Todo
7.5
10
5 a 25
30
40
50 a 125
150
Todo
Caballaje
RPM
y Otro
Vibracion
B
C
A
A
C
C
C
A
A
C
C
C
C
A
A
A
A
A
A
0.25
0.25
1.00
0.25
0.25
1.00
0.75
0.75
0.75
0.75
0.75
0.25
0.75
0.75
1.50
0.75
0.75
0.75
0.75
2
1
1
1
1
4
3
3
3
3
3
2
3
3
3
3
3
3
3
Losa en Grado
C
C
A
A
C
C
C
A
A
C
C
C
C
A
A
A
A
A
A
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
0.75
0.75
1.50
1.50
0.75
0.75
1.50
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
0.75
1.50
1.50
C
C
A
A
C
C
C
A
A
C
C
C
C
A
A
A
A
A
B
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
0.75
1.50
1.50
1.50
1.50
1.50
2.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
2.50
1.50
1.50
2.50
C
C
A
A
C
C
C
C
A
C
C
C
C
A
A
A
A
A
B
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
0.75
1.50
1.50
2.50
1.50
2.50
3.50
2.50
1.50
1.50
1.50
1.50
1.50
2.50
1.50
2.50
1.50
2.50
2.50
16
10,16
10,16
16
16
3,15
3,15
3,15
3,14,15
3,14,15
2,4,5,12
2,4,5,8,12
2,3,12
2,3,4,8,12
2,3,4,12
Ubicación del Equipo (Nota 1)
Espacio de piso
Notas de
Hasta 20 pie
20 a 30 pie
30 a 40 pie
Ref.
Tipo Tipo
Defl.
Tipo Tipo
Tipo Tipo
Defl.
Tipo Tipo
Defl.
Defl.
Base Disyun Mín,pul. Base Disy.
Base Disy Min. pulg. Base Disy. Min Pulg.
Tabla 21.1 (I-P) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47]
21.fm Page 386 Thursday, March 3, 2016 1:49 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
386
Todo
Hasta
300
301 a
500
501 y
arriba
1
1
1
A
A
A
6.4
6.4
6.4
A
A
A
4
4
4
19
64
89
3
3
3
3
C
C
C
B
3
C
C
3
3
A
4
1
4
A
B
A
4
4
A
A
1.50
2.50
3.50
1.50
2.50
3.50
0.75
1.50
0.12
19
64
89
C
C
C
B
C
C
C
B
B
A
A
A
3
3
3
3
3
3
3
4
4
4
4
4
2.50
2.50
3.50
1.50
2.50
3.50
0.75
2.50
0.25
38
64
89
3,8,9
3,8,9
3,8,9
9,8
9,8
9,8
4,9,8
4
5,18
5,18
5,8,18
Ubicación del Equipo (Nota 1)
Espacio de piso
Notas de
Hasta 20 pie
20 a 30 pie
30 a 40 pie
Ref.
Tipo Tipo
Defl.
Tipo Tipo
Tipo Tipo Defl.Min. Tipo Tipo Defl.Min
Defl.
Base Disyun Mín,pul. Base Disy.
Base Disy
pulg.
Base Disy.
Pulg.
Losa en Grado
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Calderas
Tubo de humo
Todo
Todo A
1
0.25
B
4
0.75
Tubo de agua, aleta de cobre
Todo
Todo A
1
0.12
A
1
0.12
Ventiladores Axil, Ventiladores Impelentes, Ventiladores de Gabinete, Ventiladores Centrífugos en Línea,
Hasta 22 pulg. diámetro
Todo
Todo A
2
0.25
A
3
0.75
Hasta
24 pulg. Diámetro y arriba
B
3
2.50
C
3
3.50
300
2 in. SP
301 a
B
3
0.75
B
3
1.50
500
501 y
B
3
0.75
B
3
1.50
arriba
Hasta
C
3
2.50
C
3
3.50
300
301 a
2.1 in. SP
C
3
1.50
C
3
1.50
500
Arriba
501 y
3
0.75
C
3
1.50
C
Torres de Enfriamiento
Tipo de Equipo
Caballaje
RPM
y Otro
Tabla 21.1 (I-P) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 387 Thursday, March 3, 2016 1:49 PM
Vibracion
387
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Ventiladores Helicoidales
Montado en la Pared
Montado en el Techo
Bombas de calor, Serpentín-Ventilador,
Unidades de Salas de Informática
Unidades de Condensación
40
24 pulg. Diámetro y arriba
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Hasta
300
301 a
500
501 y
Hasta
300
301 a
500
501 y
arriba
Todo
Todo
50
Todo
Ventiladores Centrífugos
Hasta 22 pulg. diámetro
Tipo de Equipo
Caballaje
RPM
y Otro
Vibracion
B
A
A
A
A
C
C
C
B
B
B
1.50
0.75
2.50
1.50
1.00
0.25
0.25
0.75
0.25
3
3
3
3
3
1
1
3
1
0.25
2.50
2
3
Losa en Grado
A
A
A
A
C
C
C
B
B
B
B
4
3
1
1
3
3
3
3
3
3
3
0.75
0.75
0.25
0.25
1.50
1.50
3.50
0.75
1.50
3.50
0.75
A
A
A
B
C
C
C
B
B
B
B
4
3
1
4
3
3
3
3
3
3
3
1.50
0.75
0.25
1.50
1.50
2.50
3.50
0.75
2.50
3.50
0.75
A/D
A/D
A
D
C
C
C
B
B
B
B
4
3
1
4
3
3
3
3
3
3
3
1.50
1.50
0.25
1.50
2.50
2.50
3.50
1.50
2.50
3.50
1.50
2,3,8,9,19
2,3,8,9,19
2,3,8,9,19
8,19
8,19
8,19
9,19
Ubicación del Equipo (Nota 1)
Espacio de piso
Notas de
Hasta 20 pie
20 a 30 pie
30 a 40 pie
Ref.
Tipo Tipo
Defl.
Tipo Tipo
Tipo Tipo Defl.Min. Tipo Tipo Defl.Min
Defl.
Base Disyun Mín,pul. Base Disy.
Base Disy
pulg.
Base Disy.
Pulg.
Tabla 21.1 (I-P) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 388 Thursday, March 3, 2016 1:49 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
388
0.75
0.75
0.75
3
3
3
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tipos Base:
A. Ninguna base, seccionadores unidos directamente al equipo (Nota 28)
B. Rieles de acero estructural o base (Notas 29 y 30)
C. Base de inercia de concreto (Nota 30)
D. Base de acera montado (Nota 31)
C
C
C
A
A
1.50
1.50
3.50
1.50
2.50
A
C
C
C
A
A
A
3
3
3
3
3
3
3
0.75
1.50
2.50
3.50
1.50
2.50
3.50
C
C
C
A
A
C
A
Tipos de Aisladores:
1. Cojinete, caucho o fibra de vidrio (Notas 20 y 21)
2. Aislador de piso de caucho o suspensión (Notas 20 y 25)
3. Aislador piso de muelle o suspensión (Notas 22, 23 y 26)
4. Aislador de resorte restringido (notas 22 y 24)
5. Restricción de empuje (Nota 27)
6. Resorte de Aire (Nota 25)
3
3
3
3
3
0.75
3.50
3
3
3
3
3
3
3
0.75
2.50
3.50
1.50
2.50
3.50
2,3,4,9
2,3,4,8,9
4,19
4,19
2,4,8,19
19
Notas de
Ref.
7
7
2,3,4
2,3,4,9
0.75
3
3
3
30 a 40 pie
Defl.
Tipo
Min
de
Pulg.
Disy.
5,6,8,17
0.75
3
A
A
Tipo
de
Base
2.50
0.75
0.75
3
Defl.
Mín,
Pulg.
3
Tipo Tipo
de
de
Base Disyun
Todo A
Hasta A
300
15,
4 in. SP 301 a
A
500
501 y A
arriba
Hasta B
300
15,
301 a B
4 in. SP 500
501 y
arriba B
Todo
Todo A/D
10
Caballaje RPM
y Otro
Ubicación del Equipo (Nota 1)
Espacio de piso
Hasta 20 pie
20 a 30 pie
Defl.
Tipo Tipo
Tipo Tipo
Min.
de
de Defl. de
de
pulg.
Base Disy
Base Disy.
Equipo Embalado en el Techo
1
0.25
D
3
0.75
Ver Referencia Nota 17
Equipo Rotativo Canalizado
A
3
0.50
A
3
0.50
A
3
0.50
A
3
0.50
Ventiladores pequeños, cajas accionadas por 600 cfm
ventiladores
601 cfm
A
3
0.75
A
3
0.75
A
3
0.75
A
3
0.75
Generadores Accionados por Motor
Todo
Todo A
3
0.75
C
3
1.50
C
3
2.50
C
3
3.50
Tuberías y Conductos
(Ver secciones sobre Aislador de Vibración y Ruido en Sistemas de Tuberías y Aislador de Vibración de Conductos para selección de aisladores.)
Unidades Integrales AH, AC, H y V
Todos
Tipo de Equipo
Losa en Grado
Tabla 21.1 (I-P) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 389 Thursday, March 3, 2016 1:49 PM
Vibracion
389
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Vibracion
Notas para la Tabla: Guía de Selección para Aislamiento de Vibración
Estas notas son las apropiadas para la columna titulada Notas de Referencia en la Tabla 47 y a otros números de referencia a través de la tabla. Aunque la guía es conservativa, casos pueden aparecer donde la transmisión de vibración al edificio está siendo excesiva. Si el problema persiste después que todos los cortos circuitos han sido eliminados, esto puede casi siempre ser corregido alterando la ruta de apoyo (ej. del techo al
piso), incrementando la deflexión aisladora, utilizando resortes de aire de baja frecuencia, cambiando la velocidad de operación, mejorando el equilibrio del componente de rotación, o, como un último recurso, cambiando la frecuencia del piso reforzando o agregando masa. La asistencia de un consultor de vibración calificado puede ser muy útil resolviendo estos problemas.
Nota 1. Las deflexiones del aislador mostradas están basadas en una solidez del piso razonablemente esperada de acuerdo a la extensión del piso y la clase de equipo. Ciertos espacios pueden dictar los espacios más altos
de aislamiento. Por ejemplo, las vigas de las varillas del techo pueden requerir una deflexión estática de 1.5 pulg. en las fábricas, pero 2.5 pulg. en edificios de oficinas comerciales.
Nota 2. Para un equipo grande capaz de generar fuerzas vibratorias sustanciales y ruido propagada por estructura sólida, incrementa la deflexión del aislador, si es necesario, por lo que la rigidez del aislador es menor que
un décimo de la rigidez de la estructura de soporte, como está definido por la deflexión debido a la carga en el soporte del equipo.
Nota 3. Para equipo ruidoso contiguo o cerca de áreas sensitivas al ruido, ver la sección sobre Aislamiento de Sonido de Sala de Equipo Mecánico.
Nota 4. Algunos diseños no pueden ser instalados directamente en aisladores individuales (tipo A) y el fabricante del equipo o un especialista en vibración debe ser consultado sobre la necesidad de apoyo suplementario
(tipo base).
Nota 5. Las condiciones de carga debido al viento deben ser consideradas. Restricciones pueden ser logradas con aisladores de resorte restringidos (tipo 4), refuerzos de amortiguadores suplementarios o topes de límites.
Ver también Capítulo 55.
Nota 6. Ciertos tipos de equipos requieren una base de montaje de curva (Tipo D. Ruido de sonido aéreo debe ser considerado.
Nota 7. Ver la sección sobre Colgadores de Tubería Flexibles y Soportes para lugares de suspensión de equipo adyacente y en salas de equipos.
Nota 8. Para evitar problemas de resonancia del aislador, seleccione deflexión del aislador para que la frecuencia de resonancia sea 40% o menos de la más baja velocidad de operación normal del equipo (ver Capítulo 8
en el Manual de ASHRAE del 2009 – Fundamentos). Algunos equipos, como mandos de frecuencia variable y equipo de alta velocidad, como enfriadores de tornillo y ventiladores de aleta axial, contienen frecuencia de
vibración muy alta. Este equipo crea nuevos cambios técnicos en el aislamiento de ruido de alta frecuencia y vibración de una estructura de edificio. Las resonancias estructurales, ambas, internas y externas, a los aisladores pueden degradar significativamente su rendimiento en altas frecuencias. Desafortunadamente, en la actualidad no existe prueba estándar para medir las propiedades dinámicas de alta frecuencia de los aisladores y
productos disponibles comercialmente no están probados para determinar su efectividad para altas frecuencias. Para reducir la posibilidad de transmisión de vibración de alta frecuencia, agregue una almohadilla gruesa
de 1 pulg. (tipo 1, Nota 20) a la placa de base de los aisladores de resorte (tipo 3, Notas 22, 23, 24). Para algunos sitios sensitivos, resortes de aire (Nota 25) pueden requerirse. Si el equipo está situado cerca de áreas sensitivas extremadamente ruidosas, siga las recomendaciones de un consultor acústico.
Nota 9. Para limitar movimiento no deseado, restricciones de empuje (tipo 5) son necesarios para todas las unidades montadas en el techo o suspendidas en el techo operando a 2 pulg. de agua o más del total de la
presión estática.
Nota 10. Bombas de más de 75 hp pueden necesitar extra masa y restricciones.
Nota 11. Ver texto para discusión completa.
Tabla 21.1 (I-P) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 390 Thursday, March 3, 2016 1:49 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
390
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Aislamiento para Equipo Específico
Nota 12. Máquinas de Refrigeración: centrífuga grande, tornillo, y máquinas de refrigeración alternativas pueden generar niveles de ruido muy altos; atención especial es requerida cuando tal equipo está instalado en
ubicaciones de piso superior o cerca de áreas sensitivas al ruido. Si el equipo está ubicado cerca de áreas extremadamente sensitivas al ruido, siga las recomendaciones de un consultor acústico.
Nota 13. Compresores: los dos compresores alternativos básicos son (1) cilindro simple o doble vertical, horizontal o culata en L, que son usualmente compresores de aire, y (2) compresores de refrigeración y aire Y,
W y cabeza de varios o multi-cilindro. Compresores de cilindro doble o simple generan fuerzas vibratorias altas requiriendo bases grandes de inercia (tipo C) y son generalmente no adecuados para ubicaciones de piso
superior. Si este equipo debe ser instalado en una ubicación de piso superior o a ubicación a nivel cerca de áreas sensitivas al ruido, los datos de fuerza desequilibrada máxima esperados deben ser obtenidos del fabricante
del equipo y un especialista en vibración consultado para diseño del sistema de aislamiento.
Nota 14. Compresores: cuando se utiliza compresores pluricilíndricos y multicabezales Y, W, obtener la magnitud de fuerzas desequilibradas del fabricante del equipo para que la necesidad de una base de inercia puede
ser evaluada.
Nota 15. Compresores: compresores montados en la base a través de 5 hp y compresores de aire tipo tanque horizontal a través de 10 hp pueden ser instalados directamente en aisladores de resorte (tipo 3) con bases
estructurales (tipo B) si es necesario, y compresores 15 a 100 hp en aisladores de resorte (tipo 3) con bases de inercia (tipo C) un peso (con una masa) 1 a 2 veces el peso del compresor (masa).
Nota 16. Bombas: bases de inercia de concreto (tipo C) son preferidos para todas las bombas de acoplado flexible y son deseados para la mayoría de las bombas de acoplado cerrado, aunque bases de acero (tipo B)
pueden utilizarse. Las bombas de acoplado cerrado no deben instalarse directamente en aisladores individuales (tipo A) porque el rotor sobresale por la base de soporte del motor, ocasionando que el montaje trasero esté
en tensión. Los requisitos principales para bases tipo C son fuerza y forma para acomodar los soportes del codo de la base. La masa no es usualmente un factor, excepto para bombas sobre 75 hp, donde la masa extra
ayuda a limitar el exceso de movimiento debido al par de arranque y fuerzas. Las bases de concreto (tipo C) deben ser diseñadas para un espesor de un décimo de la dimensión más larga con un espesor mínimo como
sigue: (1) para un máximo de 30 hp, 6 pulg.; (2) para 40 a 70 hp, 8 pulg.; y (3) para 100 hp y máximo 12 pulg.
Las bombas sobre 75 hp y bombas de varias etapas pueden exhibir un movimiento excesivo en el arranque (“agitado”); dispositivos de retención suplementarios pueden ser instalados si es necesario. Las bombas sobre
125 hp pueden generar fuerzas de arranque altas, un especialista en vibración debe ser consultado.
Nota 17. Equipo de Aire Acondicionado de Techo Integrado: Este equipo es instalado generalmente sobre estructuras de peso liviano (poca masa) que son susceptibles a problemas de transmisión de vibración y
sonido. Los problemas de sonido se ven agravados por equipo montado con restricción, que requiere grandes aberturas en el techo para suministro y retorno de aire.
La tabla muestra selecciones de aislador de vibración tipo D para todos los espacios hasta 10 pies, pero cuidado extremo debe tenerse para los equipos situados en espacios de más de 20 pies, especialmente si la construcción es viguetas abierta o losas delgadas, peso liviano (masa baja). El procedimiento recomendado es determinar la deflexión adicional causada por el equipo en el techo. Si la deflexión del techo adicional es 0.25
pulg. o menos, el aislador debe ser seleccionado para 10 veces la deflexión adicional del techo. Si la deflexión del techo adicional está sobre 0.25 pulg., refuerzo del techo suplementario debe ser instalado para traer la
deflexión del techo bajo 0.25 pulg., o la unidad debe ser relocalizada a un posición más rígida del techo.
Para unidades mecánicas capaces de generar niveles de ruido altos, montar la unidad en una plataforma sobre la cubierta del techo para proveer un espacio de aire (zona de amortiguamiento) y colocar la unidad fuera de
la penetración del techo asociado para permitir tratamiento acústico de los ductos antes de que entren al edificio.
Algunos equipos en la azotea tienen compresores, ventiladores y otros equipos internamente aislados. Este aislamiento no siempre es confiable debido a cortocircuitos internos, deflexión estática inadecuada o resonancias del panel. Es recomendado que el equipo de la azotea sobre 300 lb sea aislado externamente, como si el aislamiento interno no fuera utilizado.
Nota 18. Torres de Enfriamiento. Estas son normalmente aisladas con aisladores de resorte restringido (tipo 4) directamente bajo la torre o torre de estiba. Aisladores de alta deflexión propuestos para usarlos directamente bajo el ensamblaje del ventilador del motor deben utilizarse con precaución extrema para asegurar la estabilidad y seguridad bajo todas las condiciones climáticas. Ver Nota 5.
Nota 19. Ventiladores y Equipos de Tratamiento de Aire: Considere lo siguiente al seleccionar sistemas de aislamiento para ventiladores y equipo de tratamiento de aire:
1. Ventiladores con diámetros de rueda de 22 pulg. y menos y todos los ventiladores operando a velocidades hasta 300 rpm no generan grandes fuerzas vibratorias. Para ventiladores que operan bajo 300 rpm, seleccione
la deflexión del aislador para que la frecuencia natural del aislador sea 40% o menos que la velocidad del ventilador. Por ejemplo, para un ventilador operando a 275 rpm, 0.4 × 275 = 110 rpm. Por consiguiente, un aislador de frecuencia natural de 110 rpm o menor es requerido. Esto puede ser logrado con una deflexión del aislador de 3 pulg. (tipo 3).
2. Los conectores de conductos flexibles deben ser instalados en la toma y descarga de todos los ventiladores y equipos de tratamiento de aire para reducir la transmisión de vibración a las estructuras de los conductos de
aire.
3. Bases de inercia (tipo C) son recomendados para todos los ventiladores clase 2 y 3 y equipos de tratamiento de aire debido a que la masa extra permite el uso de resortes más rígidos, los cuales limitan los movimientos
agitados.
4. Restricciones de empuje (tipo 5) que incorporan la misma deflexión como aisladores deben ser utilizados para todas las cabezas de los ventiladores, ventiladores suspendidos y todos los montados de base y equipo de
tratamiento de aire suspendido que operen a una presión estática total de 2 pulg. o más. Ajustes a los movimientos de restricción deberán ser hechos bajo presiones estáticas operacionales normales.
Tabla 21.1 (I-P) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 391 Thursday, March 3, 2016 1:49 PM
Vibracion
391
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Sistemas de bomba de empaquetado
Terminal de succión y caja dividida
En línea grande
Tanque montado en vertical
Base montada
Alternativa Grande
Bombas
Acoplamiento cerrado
Máquinas de Refrigeración y Enfriadores
Alternativo
Centrífugo, espiral
Tornillo
Absorción
Receptor refrigerado por aire, espiral
Tornillo refrigerado por aire
Compresores de Aire y Bombas de Vacío
Tanque montado en horizontal
Tipo de Equipo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
7.5
11
Todo
Todo
Todo
5.6
7.5
3.7 a 19
22
30
37 a 93
110
Todo
B
C
A
A
C
C
C
A
A
C
C
C
C
A
A
A
A
A
A
6.4
6.4
25
6.4
6.4
25
19
19
19
19
19
6.4
19
19
38
19
19
19
19
2
1
1
1
1
4
3
3
3
3
3
2
3
3
3
3
3
3
3
C
C
A
A
C
C
C
A
A
C
C
C
C
A
A
A
A
A
A
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
19
19
38
38
19
19
38
19
19
19
19
19
19
19
19
38
19
38
38
C
C
A
A
C
C
C
A
A
C
C
C
C
A
A
A
A
A
B
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
19
38
38
38
38
38
64
38
38
38
38
38
38
38
38
64
38
38
64
Ubicación del Equipo (Nota 1)
Distancia de Piso
Potencia
Calidad
en
losa
en el Eje, RPM
Hasta 6 m
6a9m
kW y
Min.
Min. Tipo Tipo
Min. Tipo Tipo
Tipo Tipo
Otro
Defl.,
de
Defl., de
de
Defl., de
de
de
Base Aislador mm Base Aislador mm Base Aislador mm
Tabla 21.1 (SI) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47]
21.fm Page 392 Thursday, March 3, 2016 1:49 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
C
C
A
A
C
C
C
C
A
C
C
C
C
A
A
A
A
A
B
Tipo
de
Base
3
3
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
19
38
38
64
38
64
89
64
38
38
38
38
38
64
38
64
38
64
64
16
10,16
10,16
16
16
3,15
3,15
3,15
3,14,15
3,14,15
2,4,5,12
2,4,5,8,12
2,3,12
2,3,4,8,12
2,3,4,12
Notas de
9 a 12 m
Ref.
Min.
Tipo
Defl.,
de
Aislador mm
Vibracion
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
392
Hasta
300
300 a
500
501 y
más
3
3
3
C
C
C
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
501 Pa
SP
19
38
64
C
C
C
3
3
3
38
38
89
C
C
C
3
3
3
38
64
89
Calderas
Tubo de humos
Todo
Todo A
1
6.4
B
4
19
B
4
38
Tubo de agua, aletas de cobre
Todo
Todo A
1
3
A
3
A
1
3
Ventiladores Axiles, Ventiladores Impelentes, Ventiladores de Gabinete, Secciones de Ventilador, Ventiladores Centrífugos en Línea
Hasta 560 mm diámetro
Todo
Todo A
2
6.4
A
3
19
A
3
19
500 Pa Hasta
610 mm diámetro y más
B
3
64
C
3
89
C
3
89
SP
300
300 a
B
3
19
B
3
38
C
3
64
500
501 y
B
3
19
B
3
38
B
3
38
más
Torres de Enfriamiento
Tipo de Equipo
Ubicación del Equipo (Nota 1)
Distancia de Piso
Potencia
Calidad
en
losa
en el Eje, RPM
Hasta 6 m
6a9m
kW y
Min.
Min. Tipo Tipo
Min. Tipo Tipo
Tipo Tipo
Otro
Defl.,
de
Defl., de
de
Defl., de
de
de
Base Aislador mm Base Aislador mm Base Aislador mm
Hasta
A
1
6.4
A
4
89
A
4
89
300
301 a
Todo
A
1
6.4
A
4
64
A
4
64
500
501 y
A
1
6.4
A
4
19
A
4
19
arriba
4
A
3
B
C
C
3
3
3
3
C
C
3
3
C
C
4
4
4
A
B
B
4
64
64
89
38
64
89
19
64
6.4
38
64
89
3,8,9
3,8,9
3,8,9
9,8
9,8
9,8
4,9
4
5,18
5,18
5,8,18
Notas de
9 a 12 m
Ref.
Min.
Tipo
Defl.,
de
Aislador mm
A
Tipo
de
Base
Tabla 21.1 (SI) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 393 Thursday, March 3, 2016 1:49 PM
Vibracion
393
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Ventiladores Helicoidales
Montado en pared
Montado en techo
Bombas Caloríficas, Ventiladores de
Serpentín, Unidades de Sala de
Computadoras
Unidades de Condensación
610 mm diámetro y más
Ventiladores Centrífugos
Hasta 560 mm diámetro
Tipo de Equipo
Todo
Todo
Todo
Todo
Todo
Todo
Todo
Hasta
300
300 a
500
501 y
más
Hasta
300
300 a
500
501 y
más
Todo
Todo
37
30
Todo
A
A
A
A
C
C
C
B
B
B
B
19
64
38
25.4
6.4
6.4
19
6.4
3
3
1
1
3
1
38
3
3
64
3
6.4
2
3
A
A
A
A
C
C
C
B
B
B
B
4
3
1
1
3
3
3
3
3
3
3
19
19
6.4
6.4
38
38
89
19
38
89
19
A
A
A
B
C
C
C
B
B
B
B
4
3
1
4
3
3
3
3
3
3
3
38
19
6.4
38
38
64
89
19
64
89
19
Ubicación del Equipo (Nota 1)
Distancia de Piso
Potencia
Calidad en losa
en el Eje, RPM
Hasta 6 m
6a9m
kW y
Min.
Min. Tipo Tipo
Min. Tipo Tipo
Tipo Tipo
Otro
Defl.,
de
Defl., de
de
Defl., de
de
de
Base Aislador mm Base Aislador mm Base Aislador mm
A/D
A/D
A
D
C
C
C
B
B
B
B
Tipo
de
Base
Tabla 21.1 (SI) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 394 Thursday, March 3, 2016 1:49 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
4
3
1
4
3
3
3
3
3
3
3
38
38
6.4
38
64
64
89
38
64
89
38
2,3,8,9,19
2,3,8,9,19
2,3,8,9,19
8,19
8,19
8,19
9,19
Notas de
9 a 12 m
Ref.
Min.
Tipo
Defl.,
de
Aislador mm
Vibracion
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
394
Todo A
Hasta A
300
a A
1 kPa SP 301
500
501 y A
más
>1 kPa Hasta B
SP11,
300
a B
>1 kPa SP 301
500
501 y B
más
Todo
Todo A/D
11
7.5
19
6.4
3
1
19
19
19
3
3
19
3
3
19
19
3
3
D
C
C
C
A
A
A
A
3
3
3
3
3
3
3
3
19
38
38
89
38
64
89
19
C
C
C
A
A
A
A
3
3
3
3
3
3
3
38
64
89
38
64
89
19
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Tipos Base:
A. Ninguna base, seccionadores unidos directamente al equipo (Nota 28)
B. Rieles de acero estructural o base (Notas 29 y 30)
C. Base de inercia de concreto (Nota 30)
D. Base de acera montado (Nota 31)
3
3
3
3
3
3
3
Tipos de Aisladores:
1. Cojinete, caucho o fibra de vidrio (Notas 20 y 21)
2. Aislador de piso de caucho o suspensión (Notas 20 y 25)
3. Aislador piso de muelle o suspensión (Notas 22, 23 y 26)
4. Aislador de resorte restringido (notas 22 y 24)
5. Restricción de empuje (Nota 27)
6. Resorte de Aire (Nota 25)
3
3
3
12.7
19
89
64
64
89
38
64
89
19
7
7
2,3,4
5,6,8,17
2,3,4,9
2,3,4,9
2,3,4,8,9
4,19
4,19
2,4,8,19
19
Notas de
9 a 12 m
Ref.
Min.
Tipo
Defl.,
de
Aislador mm
Ver referencia Nota 17
C
C
C
A
A
C
A
Tipo
de
Base
3
12.7
A
3
12.7 A
3
12.7
A
Ventiladores pequeños, cajas accionados por 300 L/s Todo A
ventilador
301 L/s Todo A
3
19
A
3
19
A
3
19
A
Generadores accionados por motor
Todo A
3
19
C
3
38
C
3
64
C
Tuberías y Conductos
(Ver secciones sobre Aislador de Vibración y Ruido en Sistemas de Tuberías y Aislador de Vibración de Conductos para selección de aisladores)
Equipo Montado en el Techo
Unidades Integrales AH, AC, H y V
Todo
Tipo de Equipo
Ubicación del Equipo (Nota 1)
Distancia de Piso
Potencia
Calidad
en
losa
en el Eje, RPM
Hasta 6 m
6a9m
kW y
Min.
Min. Tipo Tipo
Min. Tipo Tipo
Tipo Tipo
Otro
Defl.,
de
Defl., de
de
Defl., de
de
de
Base Aislador mm Base Aislador mm Base Aislador mm
Tabla 21.1 (SI) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 395 Thursday, March 3, 2016 1:49 PM
Vibracion
395
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Vibracion
Notas para la Tabla: Guía de Selección para Aislamiento de Vibración
Estas notas son las apropiadas para la columna titulada Notas de Referencia en la Tabla 47 y a otros números de referencia a través de la tabla. Aunque la guía es conservativa, casos pueden aparecer
donde la transmisión de vibración al edificio está siendo excesiva. Si el problema persiste después que todos los cortos circuitos han sido eliminados, esto puede casi siempre ser corregido alterando la ruta
de apoyo (ej. del techo al piso), incrementando la deflexión aisladora, utilizando resortes de aire de baja frecuencia, cambiando la velocidad de operación, mejorando el equilibrio del componente de rotación, o, como un último recurso, cambiando la frecuencia del piso reforzando o agregando masa. La asistencia de un consultor de vibración calificado puede ser muy útil resolviendo estos problemas.
Nota 1. Las deflexiones del aislador mostradas están basadas en una solidez del piso razonablemente esperada de acuerdo a la extensión del piso y la clase de equipo. Ciertos espacios pueden dictar los espacios más altos de aislamiento. Por ejemplo, las vigas de las varillas del techo pueden requerir una deflexión estática de 38 mm en las fábricas, pero 64 mm en edificios de oficinas comerciales.
Nota 2. Para un equipo grande capaz de generar fuerzas vibratorias sustanciales y ruido propagada por estructura sólida, incrementa la deflexión del aislador, si es necesario, por lo que la rigidez del aislador
es menor que un décimo de la rigidez de la estructura de soporte, como está definido por la deflexión debido a la carga en el soporte del equipo.
Nota 3. Para equipo ruidoso contiguo o cerca de áreas sensitivas al ruido, ver la sección sobre Aislamiento de Sonido de Sala de Equipo Mecánico,
Nota 4. Algunos diseños no pueden ser instalados directamente en aisladores individuales (tipo A) y el fabricante del equipo o un especialista en vibración debe ser consultado sobre la necesidad de apoyo
suplementario (tipo base).
Nota 5. Las condiciones de carga debido al viento deben ser consideradas. Restricciones pueden ser logradas con aisladores de resorte restringidos (tipo 4), refuerzos de amortiguadores suplementarios o
topes de límites. Ver también Capítulo 55.
Nota 6. Ciertos tipos de equipos requieren una base de montaje de curva (Tipo D. Ruido de sonido aéreo debe ser considerado.
Nota 7. Ver la sección sobre Colgadores de Tubería Flexibles y Soportes para lugares de suspensión de equipo adyacente y en salas de equipos.
Nota 8. Para evitar problemas de resonancia del aislador, seleccione deflexión del aislador para que la frecuencia de resonancia sea 40% o menos de la más baja velocidad de operación normal del equipo
(ver Capítulo 8 en el Manual de ASHRAE del 2009—Fundamentos). Algunos equipos, como mandos de frecuencia variable y equipo de alta velocidad, como enfriadores de tornillo y ventiladores de aleta
axial, contienen frecuencia de vibración muy alta. Este equipo crea nuevos cambios técnicos en el aislamiento de ruido de alta frecuencia y vibración de una estructura de edificio. Las resonancias estructurales, ambas, internas y externas, a los aisladores pueden degradar significativamente su rendimiento en altas frecuencias. Desafortunadamente, en la actualidad no existe prueba estándar para medir las
propiedades dinámicas de alta frecuencia de los aisladores y productos disponibles comercialmente no están probados para determinar su efectividad para altas frecuencias. Para reducir la posibilidad de
transmisión de vibración de alta frecuencia, agregue una almohadilla gruesa de 25 mm (tipo 1, Nota 20) a la placa de base de los aisladores de resorte (tipo 3, Notas 22, 23, 24). Para algunos sitios sensitivos,
resortes de aire (Nota 25) pueden requerirse. Si el equipo está situado cerca de áreas sensitivas extremadamente ruidosas, siga las recomendaciones de un consultor acústico.
Nota 9. Para limitar movimiento no deseado, restricciones de empuje (tipo 5) son necesarios para todas las unidades montadas en el techo o suspendidas en el techo operando a 500 Pa o más del total de la
presión estática.
Nota 10. Bombas de más de 55 kW pueden necesitar extra masa y restricciones.
Nota 11. Ver texto para discusión completa.
Tabla 21.1 (SI) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 396 Thursday, March 3, 2016 1:49 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
396
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Aislamiento para Equipo Específico
Nota 12. Máquinas de Refrigeración: centrífuga grande, tornillo, y máquinas de refrigeración alternativas pueden generar niveles de ruido muy altos; atención especial es requerida cuando tal equipo está
instalado en ubicaciones de piso superior o cerca de áreas sensitivas al ruido. Si el equipo está ubicado cerca de áreas extremadamente sensitivas al ruido, siga las recomendaciones de un consultor acústico.
Nota 13. Compresores: los dos compresores alternativos básicos son (1) cilindro simple o doble vertical, horizontal o culata en L, que son usualmente compresores de aire, y (2) compresores de refrigeración y aire Y, W y cabeza de varios o multi-cilindro. Compresores de cilindro doble o simple generan fuerzas vibratorias altas requiriendo bases grandes de inercia (tipo C) y son generalmente no adecuados para ubicaciones de piso superior. Si este equipo debe ser instalado en una ubicación de piso superior o a ubicación a nivel cerca de áreas sensitivas al ruido, los datos de fuerza desequilibrada máxima
esperados deben ser obtenidos del fabricante del equipo y un especialista en vibración consultado para diseño del sistema de aislamiento.
Nota 14. Compresores: cuando se utiliza compresores pluricilíndricos y multicabezales Y, W, obtener la magnitud de fuerzas desequilibradas del fabricante del equipo para que la necesidad de una base de
inercia puede ser evaluada.
Nota 15. Compresores: compresores montados en la base a través de 4 kW y compresores de aire tipo tanque horizontal a través de 8 kW pueden ser instalados directamente en aisladores de resorte (tipo
3) con bases estructurales (tipo B) si es necesario, y compresores 10 a 75 kW en aisladores de resorte (tipo 3) con bases de inercia (tipo C) un peso (con una masa) 1 a 2 veces el peso del compresor (masa).
Nota 16. Bombas: bases de inercia de concreto (tipo C) son preferidos para todas las bombas de acoplado flexible y son deseados para la mayoría de las bombas de acoplado cerrado, aunque bases de acero
(tipo B) pueden utilizarse. Las bombas de acoplado cerrado no deben instalarse directamente en aisladores individuales (tipo A) porque el rotor sobresale por la base de soporte del motor, ocasionando que
el montaje trasero esté en tensión. Los requisitos principales para bases tipo C son fuerza y forma para acomodar los soportes del codo de la base. La masa no es usualmente un factor, excepto para bombas
sobre 55 kW, donde la masa extra ayuda a limitar el exceso de movimiento debido al par de arranque y fuerzas. Las bases de concreto (tipo C) deben ser diseñadas para un espesor de un décimo de la dimensión más larga con un espesor mínimo como sigue: (1) para un máximo de 20 kW, 150 mm; (2) para 30 a 35 kW, 200 mm; y (3) para 75 kW y máximo 300 mm. Las bombas sobre 55 kW y bombas de varias
etapas pueden exhibir un movimiento excesivo en el arranque (“agitado”); dispositivos de retención suplementarios pueden ser instalados si es necesario. Las bombas sobre 90 kW pueden generar fuerzas
de arranque altas, un especialista en vibración debe ser consultado.
Nota 17. Equipo de Aire Acondicionado de Techo Integrado: Este equipo es instalado generalmente sobre estructuras de peso liviano (poca masa) que son susceptibles a problemas de transmisión de
vibración y sonido. Los problemas de sonido se ven agravados por equipo montado con restricción, que requiere grandes aberturas en el techo para suministro y retorno de aire. La tabla muestra selecciones
de aislador de vibración tipo D para todos los espacios hasta 6 m., pero cuidado extremo debe tenerse para los equipos situados en espacios de más de 6 m, especialmente si la construcción es viguetas abierta o losas delgadas, peso liviano (masa baja). El procedimiento recomendado es determinar la deflexión adicional causada por el equipo en el techo. Si la deflexión del techo adicional es (6 mm) o menos,
el aislador debe ser seleccionado para 10 veces la deflexión adicional del techo. Si la deflexión del techo adicional está sobre 6 mm, refuerzo del techo suplementario debe ser instalado para traer la deflexión del techo bajo 6 mm, o la unidad debe ser relocalizada a un posición más rígida del techo.
Para unidades mecánicas capaces de generar niveles de ruido altos, montar la unidad en una plataforma sobre la cubierta del techo para proveer un espacio de aire (zona de amortiguamiento) y colocar la
unidad fuera de la penetración del techo asociado para permitir tratamiento acústico de los ductos antes de que entren al edificio.
Algunos equipos en la azotea tienen compresores, ventiladores y otros equipos internamente aislados. Este aislamiento no siempre es confiable debido a cortocircuitos internos, deflexión estática inadecuada o resonancias del panel. Es recomendado que el equipo de la azotea sobre 135 kg sea aislado externamente, como si el aislamiento interno no fuera utilizado.
Nota 18. Torres de Enfriamiento. Estas son normalmente aisladas con aisladores de resorte restringido (tipo 4) directamente bajo la torre o torre de estiba. Aisladores de alta deflexión propuestos para
usarlos directamente bajo el ensamblaje del ventilador del motor deben utilizarse con precaución extrema para asegurar la estabilidad y seguridad bajo todas las condiciones climáticas. Ver Nota 5.
Nota 19. Ventiladores y Equipos de Tratamiento de Aire: Considere lo siguiente al seleccionar sistemas de aislamiento para ventiladores y equipo de tratamiento de aire:
Ventiladores con diámetros de rueda de 560 mm y menos y todos los ventiladores operando a velocidades hasta 300 rpm no generan grandes fuerzas vibratorias. Para ventiladores que operan bajo 300 rpm,
seleccione la deflexión del aislador para que la frecuencia natural del aislador sea 40% o menos que la velocidad del ventilador. Por ejemplo, para un ventilador operando a 275 rpm, 0.4 × 275 = 110 rpm.
Por consiguiente, un aislador de frecuencia natural de 110 rpm o menor es requerido. Esto puede ser logrado con una deflexión del aislador de 75 mm (tipo 3).
Los conectores de conductos flexibles deben ser instalados en la toma y descarga de todos los ventiladores y equipos de tratamiento de aire para reducir la transmisión de vibración a las estructuras de los
conductos de aire.
Bases de inercia (tipo C) son recomendados para todos los ventiladores clase 2 y 3 y equipos de tratamiento de aire debido a que la masa extra permite el uso de resortes más rígidos, los cuales limitan los
movimientos agitados.
Restricciones de empuje (tipo 5) que incorporan la misma deflexión como aisladores deben ser utilizados para todas las cabezas de los ventiladores, ventiladores suspendidos y todos los montados de base
y equipo de tratamiento de aire suspendido que operen a una presión estática total de 500 Pa o más. Ajustes a los movimientos de restricción deberán ser hechos bajo presiones estáticas operacionales normales.
Tabla 21.1 (SI) Guía de Selección para Aislamiento de Vibración [2011A, Ch 48, Tbl 47] (Continuo)
21.fm Page 397 Thursday, March 3, 2016 1:49 PM
Vibracion
397
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Vibracion
Nota 23. Aisladores de Resorte Abierto (tipo 3) consiste de placas de carga superior e inferior con pernos de ajuste para
nivelación del equipo. Los resortes deben ser diseñados con una rigidez horizontal de por lo menos 80% de la rigidez
vertical (kx/ky) para asegurar estabilidad. Del mismo modo, los resortes deben tener una relación mínima de 0.8 para el
diámetro dividido por la altura del resorte desviado.
Nota 22. Resortes de acero son los más populares y versátiles aisladores para aplicaciones de HVAC porque están
disponibles para casi cualquier deflexión y virtualmente tienen una vida ilimitada. Los aisladores de resorte pueden tener
una barrera acústica de caucho para reducir la transmisión de vibración de alta frecuencia y ruido que puede migrar bajo la
bobina de resorte de acero. Deben estar protegidos de corrosión si son instalados en el exterior o en un ambiente corrosivo.
Los tipos básicos incluye lo siguiente:
Nota 21. Fibra de vidrio con revestimiento elástico (tipo 1). Este tipo de almohadilla aislada es almohadilla de fibra de
vidrio moldeada pre-comprimida revestida individualmente con una membrana elastomérica hermética-húmeda, flexible.
La frecuencia natural de los aisladores de vibración de fibra de vidrio debe ser esencialmente constante para el rango de
carga de funcionamiento del equipo soportado. La carga de peso (masa) es distribuida uniformemente sobre toda la
superficie de la almohadilla. Placas de carga de metal pueden utilizarse para este propósito.
Nota 20. Los aisladores de caucho están disponibles en configuraciones de almohadillas (tipo 1) y moldeadas (tipo 2). Las
almohadillas son utilizadas en capas simples o múltiples. Los aisladores moldeados vienen en una gama de 30 a 70
durómetros (una medida de rigidez). El material en exceso de 70 durómetros es usualmente ineficaz como un aislador. Los
aisladores están diseñados hasta para deflexión 0.5 pulg. (13 mm), pero son utilizados donde 0.3 pulg. (8 mm) o menos
deflexión es requerida. Caucho sólido y tejido compuesto y almohadillas de caucho también hay disponibles. Ellos proveen
capacidades de carga alta con pequeña deflexión y son utilizados como barreras de ruido bajo columnas y para soportes de
tubería. Este tipo de almohadillas trabaja bien sólo cuando ellas están apropiadamente cargadas y la carga del peso (masa)
está distribuida equitativamente sobre toda la superficie de la almohadilla. Placas de carga de metal pueden utilizarse para
este propósito.
Aisladores de Vibracion: Materiales, Tipos y Configuraciones
Notas 20 al 31incluye figuras para asistir en la evaluación de aisladores comercialmente disponibles para equipo HVAC. El aislador seleccionado para una aplicación
particular depende de la deflexión requerida, vida, costo y compatibilidad con las estructuras asociadas.
21.fm Page 398 Thursday, March 3, 2016 1:49 PM
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
398
All rights reserved. No further reproduction or distribution is permitted. Distributed by Techst
Nota 26. Suspensores de aislamiento (tipos 2 y 3) son usados para equipo y tubería suspendida y tienen caucho y resortes,
o una combinación de elementos de resorte y caucho. Los criterios deben ser similares a aisladores de resorte abiertos,
aunque estabilidad lateral es menos importante. Donde la desalineación de la varilla de soporte angular es una
preocupación, utilice suspensores que tengan suficiente espacio y/o incorporar cojinetes de caucho para prevenir que la
varilla toque la cubierta. Arreglos giratorios o de traslación pueden ser necesarios para conexiones a los sistemas de
tuberías sujetos a grandes movimientos térmicos.
Suspensores de resorte precomprimidos incorporan algunas formas de precompresión o precargas del resorte de aisladores
para minimizar el movimiento del equipo aislado o sistema. Estos son típicamente utilizados en sistemas de tuberías que
pueden cambiar peso (masa) sustancialmente entre instalación y operación.
Nota 25. Resortes de aire pueden ser diseñados para cualquier frecuencia, pero son económicos solamente en aplicaciones
con frecuencias naturales de 1.33 Hz o menos (6 pulg. [150 mm] o mayor deflexión). Ellos no transmiten ruido de alta
frecuencia y a menudo so n utilizados para reemplazar resortes de deflexión alta en trabajos de problemas (ej.
transformadores grandes en instalaciones de piso superior). Un suministro de aire constante (un compresor de aire con un
secador de aire) y válvulas de nivelación son típicamente requeridas.
Nota 24. Aisladores de resorte restringido (tipo 4) tienen pernos de sujeción para limitar el movimiento vertical como el
horizontal. Son utilizados con (a) equipo con variaciones grandes en masa (ej. Calderos, enfriadores y torres de
enfriamiento) para restringir movimiento y prevenir tensión en la tubería cuando el agua es removida y (b) equipo exterior
como unidades de condensado y torres de enfriamiento para prevenir movimiento excesivo debido a las cargas debidas al
viento. Los criterios de resorte serán los mismos como los aisladores de resorte abierto y las restricciones deben tener un
espacio adecuado para que ellos sean activados sólo cuando una restricción temporaria es necesaria.
Montajes Cerrados de aisladores de resorte alojados consiste de dos empotramientos telescópicos separados por un
material resiliente. Estos proveen apoyo lateral y algunos, amortiguamiento vertical al equipo en movimiento, pero no
limita el movimiento vertical. Debe tenerse cuidado en la selección e instalación.
21.fm Page 399 Thursday, March 3, 2016 1:49 PM
Vibracion
399
Copyrighted material licensed to armando roman on 2017-06-21 for licensee's use only.
Translated by permission. Translation by ATEAAR. ASHRAE assumes no responsibility for the accuracy of the translation.
To purchase the English language edition, contact ASHRAE.
AISLAMIENTO DIRECTO (Tipo A)
Vibracion
Nota 30. Riel
Descargar