DIAGRAMA UNIFILAR DIRECCIÓN DE INFRAESTRUCTURA CARRETERA CUARTO ELECRTRICO TABLERO 2 ALUMBRADO PÚBLICO 30 POLOS, 220 VOLTS NQ304L100S, 3F-4H, MCA. SQUARE D CON ZAPATAS PRINCIPALES A B C N T 1P - 15 A 10 KA 1 2P - 15 A 10 KA 2, 4 2P - 15 A 10 KA 3, 5 2P - 15 A 10 KA 6, 8 2P - 15 A 10 KA 7, 9 2P - 15 A 10 KA 10, 12 T-41 mm; 3F-4 AL., 1N-4 AL., 1TF-6d AL.; L=8.0; e%=0.276 2P - 15 A 10 KA 11, 13 2P - 15 A 10 KA 15, 17 2P - 15 A 10 KA 16,18 2P - 15 A 10 KA 19,21 2P - 15 A 10 KA 20,22 1P - 15 A 10 KA 23 1P - 15 A 10 KA 29 1P - 15 A 10 KA 27 A B C N T T-21 mm; 1F-12, 1N-12, 1TF-14d; L=40.0; e%=1.347 T-21 mm; 2F-10, 1TF-14d; L=70.0; e%=0.579 T-21 mm; 2F-10, 1TF-14d; L=200.0; e%=2.878 T-21 mm; 2F-10, 1TF-10d; L=180.0; e%=2.960 T-21 mm; 2F-10, 1TF-14d; L=40.0; e%=0.331 T-21 mm; 2F-10, 1TF-14d; L=180.0; e%=2.590 T-21 mm; 2F-10, 1TF-14d; L=140.0; e%=2.302 T-21 mm; 2F-10, 1TF-14d; L=140.0; e%=2.302 T-21 mm; 2F-10, 1TF-14d; L=70.0; e%=0.723 T-21 mm; 2F-10, 1TF-14d; L=180.0; e%=2.960 T-21 mm; 2F-10, 1TF-14d; L=40.0; e%=0.413 T-21 mm; 1F-10, 1TF-14d; L=45.0; e%=0.374 T-21 mm; 1F-10, 1TF-14d; L=40.0; e%=0.561 T-21 mm; 1F-10, 1TF-14d; L=52.0; e%=0.486 648.00 W CONTACTOS CUARTO PLANTA DE EMERGENCÍA 400.00 W ALUMBRADO TECHO, LADO A 700.00 W ALUMBRADO LADO A, DIRECCIÓN C.D. OBREGÓN 800.00 W ALUMBRADO CENTRAL, DIRECCIÓN C.D. OBREGÓN 400.00 W ALUMBRADO TECHO, LADO B 700.00 W ALUMBRADO LADO B, DIRECCIÓN C.D. OBREGÓN 800.00 W ALUMBRADO LADO B, DIRECCIÓN NAVOJOA 800.00 W ALUMBRADO CENTRAL, DIRECCIÓN NOVOJOA 500.00 W ALUMBRADO LATERAL TECHO LADO A 800.00 W ALUMBRADO LADO A, DIRECCIÓN NOVOJOA 500.00 W ALUMBRADO LATERAL TECHO LADO B 160.00 W ALUMBRADO CUARTO PLANTA DE EMERGENCIA 1 270.00 W ALUMBRADO CARRILES LADO A 2 180.00 W ALUMBRADO CARRILES LADO B 3 CUARTO ELÉCTRICO TABLERO 7 SANITARIOS 12 POLOS, 220 VOLTS QO112L125G, 2F-3H, MCA. SQUARE D CON ZAPATAS PRINCIPALES A B N T 1P - 15 A 10 KA T-16 mm; 1F-12, 1TF-14d; L=35.0; e%=0.449 1P - 15 A 10 KA 1P - 15 A 10 KA 1P - 15 A 10 KA 2P - 50 A 10 KA ACOMETIDA DE MEDIA TENSION PROPIEDAD DE C.F.E. 34.5 KV, 3F-4H B C N 1,3 1P - 15 A 10 KA 2 ITM PRINCIPAL ITM "B3" TRANSICIÓN AEREO EN POSTE DE CONCRETO DE 13 METROS 2P - 50 A 10 KA 3P - 300 A 35 KA 1P - 15 A 10 KA 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=5.0; %e=0.177 5 1P - 15 A 10 KA 97,411.00 W 355.05 AMP 7 1P - 15 A 10 KA 8 CORTACIRCUITO DE DE DISTRIBUCIÓN TIPO XS CON LISTÓN FUSIBLE 8A, 35 KV APARTARRAYOS POLIMÉRICOS, 35 KV 1P - 15 A 10 KA 9 1P - 15 A 10 KA MEDIDOR 13-20 2 MTS. (CONDUCTOR) 3F-4 AWG ALAMBRE DE COBRE 11 1P - 15 A 10 KA 12 kWH 1P - 15 A 10 KA 13 3P - 100 A 10 KA T-41 mm: CABLE DE CONTROL; L=10.0 ; %e=0.003 PROPIEDAD DE C.F.E. 25, 27, 29 ITM PRINCIPAL ITM "A" ITM PRINCIPAL ITM "B1" 3P - 500 A 35 KA 3P - 300 A 35 KA 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=12.0; %e=0.582 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=5.0; %e=0.177 15,6205.00 W 569.35 AMP 1TF-1/0 AWG 648.00 W CONTACTO SANITARIOS MUJERES 3,892.00 W CENTRO DE CARGA "8" A 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=5.0; %e=0.177 97,411.00 W 355.05 AMP TABLERO DE CONTROL Y TRANSFERENCIA AUTOMATICA ATS OTDA/220 3F-4H, 60Hz, 300 AMP VOLTAJE 220/127 V B C N T T-53 mm; 2F-1/0 AL, 1N-1/0 AL 1TF-4d AL; L=95.0; e%=2.620 T-21 mm; 1F-12, 1TF-14d; L=30.0; e%=0.758 T-41 mm; 2F-4 AL, 1N-4 AL, 1TF-6d AL; L=100.0; e%=3.232 T-21 mm; 1F-10, 1N-10, 1TF-14d; L=20.0; e%=0.402 T-21 mm; 1F-10, 1N-10, 1TF-14d; L=25.0; e%=0.628 T-16 mm; 1F-12, 1TF-14d; L=10.0; e%=0.062 T-21 mm; 1F-12, 1TF-14d; L=25.0; e%=0.381 T-21 mm; 1F-10, 1N-10, 1TF-14d; L=40.0; e%=1.205 T-21 mm; 1F-10, 1N-10, 1TF-14d; L=15.0; e%=0.301 T-16 mm; 1F-12, 1TF-14d; L=23.0; e%=0.191 7,318.00 W TABLERO "7" SANITARIOS 486.00 W ALUMBRADO PLANTA ALTA 3,584.00 W CENTRO DE CARGA "8" VIGILANCIA 648.00 W CONTACTOS PA ADMINISTRACIÓN 810.00 W CONTACTOS PB BAÑOS Y COMEDOR 120.00 W ALUMBRADO CUARTO ELÉCTRICO 293.00 W ALUMBRADO PLANTA BAJA 972.00 W CONTACTOS PA ENCARGADO DE TURNO 648.00 W CONTACTOS PB RECEPCIÓN 160.00 W ALUMBRADO TECHO DE AMBULANCIAS T-53 mm; 3F-1/0 AL., 1N-1/0 AL., 1TF-4d AL.; L=55.0; e%=1.559 N T 1P - 15 A 10 KA 1 1P - 15 A 10 KA 2,3 2P - 20 A 10 KA 4 TF 7,318.00 W 46.20 AMP T 2P - 100 A 10 KA 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=5.0; %e=0.177 TRANSFORMADOR TIPO POSTE DE 150 KVA OPERACION ESTRELLA-ESTRELLA CORRIENTE NOMINAL: 393.66 AMP ALT OP: 1000 M.S.N.M. Z% = 4.0, 60 Hz VOLTAJE PRIMARIO 34,500 Volts VOLTAJE SECUNDARIO 220 / 127 Volts T BODEGA CENTRO DE CARGA 8 VIGILANCIA QOX204, 2F-3H, MCA. SQUARE D T-53 mm; 2F-1/0 AL, 1N-1/0 AL 1TF-4d AL; L=95.0; e%=2.620 10,12 T CONTACTO SANITARIOS HOMBRES B C A 2,4 T1 2P- 100 A 10 KA B N 648.00 W B C T-41 mm; 2F-4 AL, 1N- AL, 1TF-6d; L=20.0; e%=0.702 7,9 A BOMBA HIDRONEUMATICO T T-16 mm; 1F-12, 1TF-14d; L=35.0; e%=1.179 6 GENERADOR ELECTRICO DE 80 KW MODELO PLY80 MARCA GENERAC OTTOMOTORES BASE INTEGRADO CONECTADO A TANQUE DE DIESEL F.P. 0.80, 60 Hz VOLTAJE DE ENTRADA 220/127 Volts VOLTAJE DE SALIDA 220/127 Volts ALUMBRADO EXTERIOR 1,492.00 W T-16 mm; 1F-12, 1TF-14d; L=35.0; e%=1.179 5 CUARTO ELÉCTRICO TABLERO 3 OFICINAS 30 POLOS, 220 VOLTS NQ304L100S, 3F-4H, MCA. SQUARE D CON ZAPATAS PRINCIPALES ALUMBRADO SANITARIOS MUJERES 144.00 W T-16 mm; 1F-10, 1TF-12d; L=36.0; e%=1.665 4 7,658.00 W 27.91 AMP ALUMBRADO SANITARIOS HOMBRES 247.00 W T-16 mm; 1F-12, 1TF-14d; L=35.0; e%=0.262 1P - 20 A 10 KA TF 247.00 W T-16 mm; 1F-12, 1TF-14d; L=35.0; e%=0.449 1P - 15 A 10 KA N T T-16 mm; 1F-12, 1TF-14d; L=18.0; e%=0.388 T-16 mm; 1F-10, 1N-10; 1TF-10d; L=20.0; e%=1.033 T-16 mm; 1F-10, 1N-10; 1TF-14d; L=15.0; e%=0.324 696.00 W ALUMBRADO VIGILANCIA 2500.00 W CONTACTO VIGILANCIA 696.00 W CONTACTO VIGILANCIA TF 3,892.00 W 24.57 AMP PRINCIPAL TF 15,039.00 W 54.82 AMP LISTA DE MATERIALES UNIDAD CUARTO ELÉCTRICO TABLERO 4 AIRES ACONDICIONADOS 30 POLOS, 220 VOLTS NQ424AB225S, 3F-4H, MCA. SQUARE D CON ZAPATAS PRINCIPALES A B C N T 2P - 30 A 10 KA 1, 3 2P - 30 A 10 KA 2, 4 2P - 30 A 10 KA 5,7 2P - 30 A 10 KA 6,8 2P - 30 A 10 KA 9,11 2P - 30 A 10 KA 10,12 2P - 30 A 10 KA 13,15 AJUSTADO 3P - 225 A 25 KA 2P - 30 A 10 KA 14,16 2P - 30 A 10 KA 17,19 2P - 30 A 10 KA 18,20 2P - 30 A 10 KA 21,23 2P - 30 A 10 KA 22,24 2P - 30 A 10 KA 25,27 2P - 30 A 10 KA 26,28 2P - 30 A 10 KA 31,29 A B C N T-35 mm; 2F-8, 1TF-10d; L=45.0; e%=1.548 T-35 mm; 2F-8, 1TF-10d; L=40.00; e%=1.376 T-35 mm; 2F-8, 1TF-10d; L=35.0; e%=1.204 T-35 mm; 2F-8, 1TF-10d; L=10.0; e%=0.344 T-35 mm; 2F-8, 1TF-10d; L=25.0; e%=0.860 T-35 mm; 2F-8, 1TF-10d; L=25.0; e%=0.860 T-35 mm; 2F-8, 1TF-10d; L=25.0; e%=0.860 T-35 mm; 2F-8, 1TF-10d; L=25.0; e%=0.860 T-35 mm; 2F-8, 1TF-10d; L=8.00; e%=0.275 T-35 mm; 2F-8, 1TF-10d; L=16.0; e%=0.550 T-35 mm; 2F-8, 1TF-10d; L=18.0; e%=0.619 T-35 mm; 2F-8, 1TF-10d; L=30.0; e%=1.032 T-35 mm; 2F-8, 1TF-10d; L=35.0; e%=1.204 T-35 mm; 2F-8, 1TF-10d; L=26.0; e%=0.894 T-35 mm; 2F-8, 1TF-10d; L=32.0; e%=1.100 DESCRIPCION m CABLE CAL. 12 AWG THHW-LS MCA.VIAKON (VERDE) m CABLE CAL. 14 AWG THHW-LS MCA.VIAKON (VERDE) m CABLE CAL. 12 AWG THHW-LS MCA.VIAKON (NEGRO) m m m CABLE CAL. 12 AWG THHW-LS MCA.VIAKON (BLANCO) CABLE CAL. 14 AWG THHW-LS MCA.VIAKON (NEGRO) CABLE CAL. 14 AWG THHW-LS MCA.VIAKON (BLANCO) 2,500.00 W AIRE ACONDICIONADO CASETA 1B 2,500.00 W AIRE ACONDICIONADO CASETA 2B PZA. TUBO CONDUIT DE PVC DE (1/2", 3/4", 1") MCA. POLIFLEX 2,500.00 W AIRE ACONDICIONADO CASETA 3B 2,500.00 W AIRE ACONDICIONADO TELEMÁTICA 1 PZA. PZA. CENTRO DE CARGA QO8 Y ACCESORIOS, MCA. SQUARE D CAJA CUADRADA DE PVC TAM.4X4" PROF.2 1/8" (C/CHIQ.1/2,3/4") CON TAPA PLANA, MCA.COOPER 2,500.00 W AIRE ACONDICIONADO CASETA 4A PZA. CAJA CUADRADA DE PVC TAM.4 11/16X4 11/16" PROF.2 1/8" (C/CHIQ.1 1/4") CON TAPA, MCA.COOPER PZA. CAJA RECTANGULAR DE PVC, TAM.4X2 1/8" PROF.1 1/2", MCA.COOPER PZA. ABRAZADERA P/UNICANAL DE (3/4, 1 1/4") MCA. COOPER 2,500.00 W AIRE ACONDICIONADO TELEMÁTICA 2 2,500.00 W AIRE ACONDICIONADO ADMINISTRACIÓN 1 PZA. CONTRATUERCA GALVANIZADA DE (1/2, 3/4, 1, 1 1/4") MCA. COOPER 2,500.00 W AIRE ACONDICIONADO ADMINISTRACIÓN 2 PZA. CONECTOR DE RESORTE PARA CABLE, MCA. 3M 2,500.00 W AIRE ACONDICIONADO PASILLO PLANTA ALTA PZA. CONECTOR PARA CABLE USO RUDO 1/2", MCA. COOPER 2,500.00 W AIRE ACONDICIONADO ENCARGADO DE TURNO 1 PZA. CONECTOR CONDUIT PARED PVC DE (1/2, 3/4, 1 1/4") MCA. COOPER 2,500.00 W AIRE ACONDICIONADO ENCARGADO DE TURNO 2 2,500.00 W AIRE ACONDICIONADO CASETA 5A 2,500.00 W AIRE ACONDICIONADO CASETA 6A 2,500.00 W AIRE ACONDICIONADO RECEPCIÓN 2,500.00 W AIRE ACONDICIONADO LOCKERS PZA. PZA. PZA. PZA. PZA. PZA. PZA. TMO. PZA. CURVA CONDUIT PVC DE (1/2, 3/4, 1 1/4") MCA. COOPER MONITOR PVC DE (1/2, 3/4, 1, 1 1/4") MCA. COOPER SOPORTE TIPO COLGANTE SIMPLE C/CLIP, P/TUBERIA SOPORTE TIPO COLGANTE SIMPLE P/CAJA REGISTRO SOPORTE TIPO COLUMPIO P/TUBERIAS TERMINAL DE ANILLO AMARILLO (CAL.12-10 AWG) MCA. BURNDY TORNILLO CABEZA REDONDA DE 3/16" TUBERIA CONDUIT PVC DE (1/2, 3/4, 1 1/4) MCA. OMEGA LUMINARIO DE EMERGENCIA CON 2 LAMPARAS LED, MCA. STEVEZ T TF 37,500.00 W 136.68 AMP TELEMÁTICA 1 TABLERO 5 TELEMÁTICA 30 POLOS, 220 VOLTS NQ304L100S, 3F-4H, MCA. SQUARE D CON ZAPATAS PRINCIPALES ACONDICIONADOR DE VOLTAJE DE 100 KVA MARCA VOGAR GABINETE G-8 3F-4H, F.P. 0.99, 60 Hz VOLTAJE NOMINAL 220/127 Volts PLANTA DE EMERGENCIA TABLERO 1 PRINCIPAL 30 POLOS, 220 VOLTS NF304AB42S, 3F-4H, MCA. SQUARE D CON INTERRUPTOR PRINCIPAL A B C N 3P - 50 A 25 KA 3P - 100 A 25 KA 3P - 125 A 25 KA LAN-3100 7, 9, 11 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=5.0; %e=0.151 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=5.0; %e=0.151 2T-103 mm: 6F-400 AL., 2N-400 AL., 2TF-1/0d AL.; L=35.0; %e=1.059 AJUSTADO 3P - 400 A 42 KA 3P - 50 A 25 KA 8, 10, 12 3P - 100 A 25 KA 97,411.00 W 355.05 AMP 97,411.00 W 355.05 AMP 13, 15, 17 3P - 50 A 25 KA 14, 16, 18 2P - 100 A 25 KA 23,25 1P - 15 A 25 KA 21 2P - 100 A 25 KA 20,22 A B C N T T-41 mm; 3F-4 AL., 1N-4 AL., 1TF-6d AL.; L=35.0; e%=1.209 7,658.00 W TABLERO 2 ALUMBRADO PUBLICO T-53 mm; 3F-1/0 AL., 1N-1/0 AL., 1TF-4d AL.; L=45.0; e%=1.275 15,039.00 W TABLERO 3 OFICINAS T-63 mm; 3F-2/0 AL., 1N-2/0 AL., 1TF-4d AL.; L=45.0; e%=2.564 37,500.00 W TABLERO 4 AIRES ACONDICIONADOS T-41 mm; 3F-4 AL., 1N-4 AL., 1TF-6d AL.; L=65.0; e%=1.233 4,208.00 W TABLERO 5 TELEMÁTICA 1 T-53 mm; 3F-2/0 AL., 1N-2/0 AL., 1TF-6d AL.; L=70.0; e%=1.006 T-41 mm; 3F-4 AL., 1N-4 AL., 1TF-6d AL.; L=150.0; e%=1.009 T-53 mm; 2F-1/0 AL., 1N-1/0 AL., 1TF-4d AL.; L=50.0; e%=2.733 T-16 mm; 1F-12, 1N-12, 1TF-14d; L=45.0; e%=1.739 T-53 mm; 2F-1/0 AL., 1N-1/0 AL., 1TF-4d AL.; L=70.0; e%=1.132 1P - 15 A 10 KA 3 1P - 15 A 10 KA 4 1P - 15 A 10 KA 5 1P - 15 A 10 KA 7 1P - 15 A 10 KA 9,456.00 W TABLERO 6 TELEMÁTICA 2 1,492.00 W BOMBA TRATAMIENTO DE AGUA 8 14,500.00 W SCHNEIDER TELEMÁTICA 9 746.00 W BOMBA DE AGUA 11 8 1P - 15 A 10 KA 1P - 15 A 10 KA 1P - 15 A 10 KA 6,812.00 W 1P - 15 A 10 KA CENTRO DE CARGA 8 VIGILANCÍA EQUIPO UPS DE 15 KVA MARCA VOGAR 5-9 MINUTOS TIEMPO DE RESPALDO 3F-4H, F.P. 0.90, 60 Hz VOLTAJE NOMINAL 220/127 Volts TF TELEMÁTICA 1 ITM "C" PANELES SOLARES TABLERO FV SISTEMA FOTOVOLTAICO 30 POLOS, 220 VOLTS NQ304AB225S, 3F-4H, MCA. SQUARE D CON INTERRUPTOR PRINCIPAL C N 2P - 40 A 10 KA 2P - 40 A 10 KA 2, 4 2P - 40 A 10 KA 5, 7 2P - 40 A 10 KA 6, 8 AJUSTADO 3P - 200 A 25 KA 2P - 40 A 10 KA 9, 11 2P - 40 A 10 KA 10, 12 2P - 40 A 10 KA 17,19 1P - 15 A 10 KA 14,16 1P - 15 A 10 KA 13 1P - 15 A 10 KA 15 A B C N 3P - 50 A 25 KA T-41 mm; 3F-4 AL., 1N-4 AL., 1TF-6d AL.; L=45.0; e%=0.854 T-27 mm; 2F-8, 1N-8, 1TF-10d; L=6.0; e%=0.636 T-27 mm; 2F-8, 1N-8, 1TF-10d; L=8.0; e%=0.847 T-27 mm; 2F-8, 1N-8, 1TF-10d; L=4.0; e%=0.350 T-27 mm; 2F-8, 1N-8, 1TF-10d; L=5.0; e%=0.401 T-27 mm; 2F-8, 1N-8, 1TF-10d; L=9.0; e%=0.953 T-27 mm; 2F-8, 1N-8, 1TF-10d; L=10.0; e%=1.059 T-27 mm; 2F-8, 1N-8, 1TF-10d; L=11.0; e%=1.165 T-27 mm; 2F-8, 1N-8, 1TF-14d; L=29.0; e%=3.072 T-16 mm; 1F-10, 1N-14, 1TF-14d; L=25.0; e%=0.104 T-16 mm; 1F-10, 1N-14, 1TF-14d; L=25.0; e%=0.421 7,000.00 W INVERSOR 3 7,000.00 W INVERSOR 4 6,360.00 W INVERSOR 1 5,830.00 W INVERSOR 2 7,700.00 W INVERSOR 5 7,700.00 W INVERSOR 6 7,700.00 W INVERSOR 7 7,700.00 W INVERSOR 8 80.00 W ALUMBRADO EN CUARTO DE INVERSORES 324.00 W CONTACTO EN CUARTO DE INVERSORES 12 3P - 50 A 10 KA 25, 27, 29 A B C N T T-16 mm; 1F-12, 1N-12, 1TF-10d; L=15.0; e%=0.062 T-16mm; 1F-10, 1TF-12d; L=35.0; e%=0.703 T-16 mm; 1F-10, 1N-10, 1TF-10d; L=40.0; e%=0.803 T-16 mm; 1F-10, 1N-10, 1TF-10d; L=20.0; e%=0.201 T-16 mm; 1F-10, 1N-10, 1TF-10d; L=15.0; e%=0.238 T-16 mm; 1F-12, 1TF-12d; L=16.0; e%=0.080 T-16 mm; 1F-10, 1N-10, 1TF-10d; L=18.0; e%=0.090 T-16 mm; 1F-10, 1N-10, 1TF-10d; L=27.0; e%=0.428 CONTACTOS ENCARGADOS DE TURNO 324.00 W CONTACTOS PASILLO PA 512.00 W CONTACTOS TELEMÁTICA 162.00 W CONTACTOS TELEMÁTICA 162.00 W CONTACTOS TELEMÁTICA 512.00 W CONTACTOS TELEMÁTICA 512.00 W CONTACTOS TELEMÁTICA 324.00 W CONTACTOS TELEMÁTICA SIMBOLOGIA Acometida M T-16 mm; 1F-10, 1N-10, 1TF-10d; L=22.0; e%=0.221 324.00 W 1P - 15 A 10 KA 1P - 20 A 10 KA CONTACTOS TELEMÁTICA 3 MC-4; 3F-4 AL., 1N-4 AL., 1TF-6d AL.; L=5.0; e%=0.095 C 4,208.00 W 15.34 AMP T-16 mm; 1F-10, 1N-10, 1TF-14d; L=8.0; e%=0.121 78.00 W LUMINARIAS 486.00 W CONTACTOS CASETA T-27 mm; 1F-10, 1N-10, 1TF-12d; L=50.0; e%=0.874 C N T-21 mm; 1F-10, 1N-10, 1TF-14d; L=15.0; e%=0.301 T-21 mm; 1F-10, 1N-10, 1TF-14d; L=15.0; e%=0.301 1P - 15 A 10 KA T-21 mm; 1F-10, 1N-10, 1TF-14d; L=15.0; e%=0.301 4 1P - 15 A 10 KA T-21 mm; 1F-10, 1N-10, 1TF-14d; L=15.0; e%=0.226 5 1P - 15 A 10 KA T-21 mm; 1F-10, 1N-10, 1TF-14d; L=22.0; e%=0.349 6 1P - 15 A 10 KA Motor PRINCIPAL 1P - 20 A 10 KA 1P - 15 A 10 KA 1P - 15 A 10 KA 1P - 15 A 10 KA TF 1P - 20 A 10 KA ALUMBRADO TELEMÁTICA EXTERIOR 3 B 648.00 W CONTACTOS TELEMÁTICA EXTERIOR 648.00 W CONTACTOS TELEMÁTICA EXTERIOR 648.00 W CONTACTOS TELEMÁTICA EXTERIOR 486.00 W CONTACTOS TELEMÁTICA EXTERIOR 512.00 W CONTACTOS TELEMÁTICA EXTERIOR 512.00 W CONTACTOS TELEMÁTICA EXTERIOR 100.00 W CARRIL 1B N T T-16 mm; 1F-10, 1N-10, 1TF-14d; L=13.0; e%=0.141 1P - 15 A 10 KA 350.00 W T-21 mm; 1F-10, 1N-10, 1TF-14d; L=30.0; e%=0.093 1P - 15 A 10 KA T-21 mm; 1F-10, 1N-10, 1TF-14d; L=25.0; e%=0.077 11 N 1P - 20 A 10 KA 1P - 15 A 10 KA 1P - 20 A 10 KA 1P - 15 A 10 KA C CARRIL 2B 100.00 W CARRIL 3B 100.00 W CARRIL 4A 1P - 15 A 10 KA T-27 mm; 1F-10, 1N-10, 1TF-14d; L=35.0; e%=0.108 13 1P - 15 A 10 KA T-21 mm; 1F-10, 1N-10, 1TF-14d; L=40.0; e%=0.124 14 1P - 15 A 10 KA T-21 mm; 1F-10, 1N-10, 1TF-14d; L=45.0; e%=0.139 15 100.00 W CARRIL 5A 100.00 W 1P - 15 A 10 KA CARRIL 6A 1P - 15 A 10 KA 1P - 15 A 10 KA T-16 mm; 1F-10, 1N-10, 1TF-14d; L=30.0; e%=0.232 18 1P - 15 A 10 KA 19 1P - 15 A 10 KA 20 1P - 15 A 10 KA 21 1P - 15 A 10 KA 22 1P - 15 A 10 KA 1P - 15 A 10 KA 1P - 15 A 10 KA 1P - 15 A 10 KA 29 3P - 100 A 10 KA 26, 28, 30 1P - 20 A 10 KA A 564.00 W CASETA 5A 564.00 W CASETA 6A 250.00 W TDISA 3B 250.00 W TDISA 4A 250.00 W TDISA 5A 250.00 W 250.00 W MC-4; 3F-2/0 AL., 1N-2/0 AL., 1TF-6d AL.; L=5.0; e%=0.072 CUADRO DE AREA AREA TOTAL T-16 mm; 1F-12, 1N-12, 1TF-12d; L=15.0; e%=0.061 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=8.0; e%=0.121 78.00 W 486.00 W T-27 mm; 1F-10, 1N-10, 1TF-12d; L=50.0; e%=0.874 LUMINARIAS CONTACTOS CASETA PRINCIPAL N T T-16 mm; 1F-12, 1N-12, 1TF-12d; L=15.0; e%=0.061 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=8.0; e%=0.121 78.00 W 486.00 W T-16 mm; 1F-10, 1N-10, 1TF-12d; L=55.0; e%=0.962 LUMINARIAS CONTACTOS CASETA PRINCIPAL TF CASETA 5A CENTRO DE CARGA CASETA 3 POLOS, 220 VOLTS QOD3, 1F-2H, MCA. SQUARE D CON ZAPATAS PRINCIPALES A N T 1P - 20 A 10 KA 1 1P - 15 A 10 KA 2 TELEPEAJE 1B 1P - 20 A 10 KA 3 TELEPEAJE 6A A N T-16 mm; 1F-12, 1N-12, 1TF-12d; L=15.0; e%=0.061 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=8.0; e%=0.121 78.00 W 486.00 W T-27 mm; 1F-10, 1N-10, 1TF-12d; L=60.0; e%=1.049 LUMINARIAS CONTACTOS CASETA PRINCIPAL T TF 564.00 W 6.17 AMP PRINCIPAL TF 9,456.00 W 34.47 AMP ESTUDIO Y PROYECTO DE REINGENIERÍA DEL SISTEMA ELÉCTRICO DE LAS PLAZAS DE COBRO, ESTACIÓN DON, FUNDICIÓN, GUAYMAS, ESPERANZA, HERMOSILLO Y MAGDALENA, DE LA AUTOPISTA ESTACIÓN DON NOGALES. DSP-K-30 MC4-2; 3F-1/0 AL., 1N-1/0 AL., 1TF-6d AL.; L=5.0; e%=0.072 CASETA 6A CENTRO DE CARGA CASETA 3 POLOS, 220 VOLTS QOD3, 1F-2H, MCA. SQUARE D CON ZAPATAS PRINCIPALES 9,456.00 W 34.47 AMP A N T 1P - 20 A 10 KA 1 1P - 15 A 10 KA 2 1P - 20 A 10 KA 3 A N T T-16 mm; 1F-12, 1N-12, 1TF-12d; L=15.0; e%=0.061 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=8.0; e%=0.121 T-27 mm; 1F-10, 1N-10, 1TF-12d; L=60.0; e%=1.049 TF 564.00 W 6.17 AMP CUARTO PARAMÉDICOS CENTRO DE CARGA 9 PARAMÉDICOS QOX206, 2F-3H, MCA. SQUARE D B C N T 1P - 15 A 10 KA 1P - 20 A 10 KA 2 2P - 30 A 10 KA 3,4 2P - 50 A 10 KA 5,6 2P - 100 A 10 KA 7,8 B C N T 6,812.00 W 43.01 AMP TF T-16 mm; 1F-10, 1N-10, 1TF-14d; L=15.0; e%=0.301 T-16 mm; 1F-10, 1N-10; 1TF-10d; L=15.0; e%=0.062 648.00 W CONTACTOS 80.00 W ALUMBRADO 2,500.00 W AIRE ACONDICIONADO VIGILANCIA 3,584.00 W CC, SEGURIDAD PRIVADA CUARTO PARAMÉDICOS CENTRO DE CARGA 9 PARAMÉDICOS QOX206, 2F-3H, MCA. SQUARE D B T-16 mm; 2F-10, 1N-10, 1TF-10d; L=15.0; e%=0.775 T-27 mm; 2F-4 AL., 1N-4 AL., 1TF-10d AL.; L=30.0; e%=0.980 23,853.49 M2 564.00 W 6.17 AMP N T 1 58,446.00 Watts T 1P - 15 A 10 KA TDISA 2B T-21 mm; 1F-10, 1N-10, 1TF-14d; L=45.0; e%=0.787 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=45.0; e%=0.349 N 3 T-21 mm; 1F-10, 1N-10, 1TF-14d; L=40.0; e%=0.699 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=35.0; e%=0.271 25 CASETA 3B 2 CASETA 4A T-16 mm; 1F-10, 1N-10, 1TF-14d; L=35.0; e%=0.271 24 1 564.00 W T-16 mm; 1F-10, 1N-10, 1TF-14d; L=30.0; e%=0.232 23 Carga demandada T 1P - 20 A 10 KA CASETA 1B T-21 mm; 1F-10, 1N-10, 1TF-14d; L=35.0; e%=0.612 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=25.0; e%=0.194 0.6 CASETA 4A CENTRO DE CARGA CASETA 3 POLOS, 220 VOLTS QOD3, 1F-2H, MCA. SQUARE D CON ZAPATAS PRINCIPALES 564.00 W 250.00 W Factor de demanda CASETA 2B A T-21 mm; 1F-10, 1N-10, 1TF-14d; L=25.0; e%=0.437 17 CONTACTOS CASETA PRINCIPAL TF 564.00 W T-21 mm; 1F-12, 1N-12, 1TF-14d; L=35.0; e%=0.612 16 N 97,411.00 Watts 564.00 W 6.17 AMP 564.00 W T-21 mm; 1F-10, 1N-10, 1TF-14d; L=30.0; e%=0.524 12 486.00 W T-27 mm; 1F-12, 1N-12, 1TF-12d; L=45.0; e%=0.787 Carga total instalada LUMINARIAS T ROBOTICA 100.00 W 78.00 W CASETA 3B CENTRO DE CARGA CASETA 3 POLOS, 220 VOLTS QOD3, 1F-2H, MCA. SQUARE D CON ZAPATAS PRINCIPALES 3 10 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=8.0; e%=0.121 564.00 W 6.17 AMP 2 9 T-16 mm; 1F-12, 1N-12, 1TF-12d; L=15.0; e%=0.061 TF 1 T-21 mm; 1F-10, 1N-10, 1TF-14d; L=35.0; e%=0.108 8 T 168.00 W CARGA INSTALADA T 1 C T-21 mm; 1F-10, 1N-10, 1TF-14d; L=15.0; e%=0.238 7 C N 2 T-16 mm; 1F-12, 1TF-14d; L=15.0; e%=0.131 1P - 15 A 10 KA A B B T 3 TELEMÁTICA 2 ITM "D" Contactos a 220 volts TF CASETA 1B CENTRO DE CARGA CASETA 3 POLOS, 220 VOLTS QOD3, 1F-2H, MCA. SQUARE D CON ZAPATAS PRINCIPALES TELEMÁTICA 2 TABLERO 6 TELEMÁTICA 30 POLOS, 220 VOLTS NQ304L100S, 3F-4H, MCA. SQUARE D CON ZAPATAS PRINCIPALES 2 EQUIPO UPS DE 30 KVA MARCA VOGAR 5-30 MINUTOS TIEMPO DE RESPALDO 3F-4H, F.P. 0.90, 60 Hz VOLTAJE NOMINAL 220/127 Volts T T-16 mm; 1F-12, 1N-12, 1TF-12d; L=15.0; e%=0.061 564.00 W 6.17 AMP 1P - 15 A 10 KA 58,794.00 W 214.30 AMP N PRINCIPAL TF Contactos duplex T 1P - 20 A 10 KA MC4-4; 3F-4 AL., 1N-4 AL., 1TF-6d AL.; L=5.0; e%=0.095 4,208.00 W 15.34 AMP N Medidor Alumbrado CASETA 2B CENTRO DE CARGA CASETA 3 POLOS, 220 VOLTS QOD3, 1F-2H, MCA. SQUARE D CON ZAPATAS PRINCIPALES 2 1P - 15 A 10 KA 9,456.00 W 34.47 AMP CONTACTOS ADMINISTRACIÓN 648.00 W 1 T-16 mm; 1F-10, 1N-10, 1TF-10d; L=15.0; e%=0.151 1 3P - 80 A 25 KA ALUMBRADO TELEMÁTICA INTERIOR 648.00 W C T-16 mm; 1F-10, 1N-10, 1TF-10d; L=20.0; e%=0.317 A B T-53 mm; 3F-1/0 AL., 1N-1/0 AL., 1TF-6d AL.; L=35.0; e%=0.503 80.00 W DSP-K-15 4.208.00 W 15.34 AMP T 1, 3 T 1P - 15 A 10 KA 97,411.00 W 355.05 AMP A B N 2 1, 3, 5 3P - 300 A 35 KA B C 1P - 15 A 10 KA T 2, 4, 6 ITM PRINCIPAL ITM "B2" A 1 C N T 1P - 15 A 10 KA 1 1P - 20 A 10 KA 2,3 T-53 mm; 2F-1/0 AL., 1N-1/0 AL., 1TF-4d AL.; L=70.0; e%=1.797 2P - 30 A 10 KA 4 B C N T 3,584.00 W 22.63 AMP TF T-16 mm; 1F-12, 1TF-14d; L=10.0; e%=0.058 T-16 mm; 2F-10, 1N-10; 1TF-10d; L=10.0; e%=0.517 T-16 mm; 1F-10, 1N-10, 1TF-14d; L=10.0; e%=0.301 112.00 W CONTACTOS 2,500.00 W ALUMBRADO 972.00 W AIRE ACONDICIONADO VIGILANCIA 78.00 W 486.00 W LUMINARIAS CONTACTOS CASETA PRINCIPAL DIAGRAMA UNIFILAR PE-14
Puede agregar este documento a su colección de estudio (s)
Iniciar sesión Disponible sólo para usuarios autorizadosPuede agregar este documento a su lista guardada
Iniciar sesión Disponible sólo para usuarios autorizados(Para quejas, use otra forma )