Ports available for ISO
Testing?
A1, A2, A3 for Air Flow
Vm, Vr, Vp for Vacuum
Page 1
Start Here
Short Test Note:
Complete all the tests in red. For the
short test only you may test in milking
position* without teatcup plugs. You
may test pulsation with plugs only in
the units you are testing.
1
Yes
Connect AFM to
Interceptor. Remove any
Control or Float Valves.
Ensure flushing systems
are not operating.
Drain and
assemble
Plant
Yes
No
Wait until
15
minutes
elapsed
RECEIVER
Nominal
Working
Vacuum
EXCEPTION
FROM ISO
1b.
Nominal Working
Vacuum kPa.
This may not be
available so use
a vacuum within
the guidelines
given in the
standards.
LEGEND:
(Short test in red)
1
Measure system vacuum levels
2
Check Reserve Characteristics
3
Check Regulation Characteristics
4
Measure Vacuum Drop in Airline
5
Test Regulation Sensitivity
6
Reserve (Vacuum off Cluster)
7
Check Vacuum Gauge Accuracy
8
Test Vacuum Pump(s)
9
Vacuum Pump Exhaust Pressure
10
Test Airline & Milk System Leakage
11
Automatic Cluster Removers
12
Cluster Air Admission
13
Individual Cluster Air Admission
14
Pulsator & Ancillary Equipment
15
Test Pulsation
07/20
Configure Machine in Milking
Position* Complete Test Report
Part A and Visual Check Part 2
Yes
No
Open AFM.
Check
Regulator is
free.
• Endeavor to install Ports or
• Carry out Short Test or
• Discontinue Test
Read Test
Gauge at
Receiver
(Vm)
1a.
Working
Vacuum at
Receiver
kPa
Vacuum
<55 kPa
No
*Milking Position:
Liners plugged, vacuum
on cluster, regulator(s)
or VSD Transducer
connected, all controls
e.g. ACR’s in the milking
position. All vacuum
operated equipment
connected.
Note: Some tests
require milking position*
but with
Vacuum off Cluster.
2 Check Reserve Characteristics
Measure System Vacuum Levels
15 minutes
elapsed
Start the plant
and carefully
close the AFM.
Read Test
Gauge at
Regulator or
VSD Sensor
(Vr)
Vacuum
Regulation
Deviation
1c.
Vac Reg Dev
difference
between 1a.
& 1b. kPa
1d.
Working
Vacuum
Regulator
kPa
REGULATOR
Read Test
Gauge
near Vacuum
Pump
(Vp)
Machine in
Milking Position*
and test gauge
at Receiver (Vm)
and Regulator
(Vr)
1e.
Working
Vacuum near
Vacuum Pump
kPa
VACUUM PUMP
INTERCEPTOR
RECEIVER
REGULATOR
Adjust Test
Gauge at
receiver to
2kPa below
working
Vacuum 1a
Adjust Test
Gauge at
regulator to
2kPa below
Working
Vacuum 1d
Remove Regulator or
Transducer
Adjust Test Gauge
at receiver to 2kPa
below Working
Vacuum 1a
Subtract
2a from
2c
Adjust Test Gauge
at regulator to
2kPa below
Working Vacuum
1d
Record
Regulator
Leakage
Record
Required
Standard
Effective
Reserve L/min
Record
Required
Cleaning
Reserve
2a.
Effective
Reserve
L/min
2b.
Airflow at
2kPa
below
1d
2c.
Manual
Reserve
L/min
2d.
Regulation
Loss
L/min
2e.
Airflow at 2kPa
below vacuum 1d.
Regulator/transducer
disconnected
2f.
Regulator
Leakage
2e -2b
2g.
Required
Standard
Effective
Reserve L/min
2h.
Required
Cleaning
Reserve
L/min
3 Check Regulation Characteristics
Reconnect
Regulator
or
Transducer
Machine in Milking
Position*. Vacuum
Recorder at or near
Receiver (eg long
milk tube)
3a.
Average
Receiver
Vacuum
RECEIVER
Open
1 cluster for
each 32
clusters
Record
Minimum
Vacuum
Record Average
Vacuum during
Air Inlet
3b.
Minimum
Vacuum kPa
3c.
Average Vacuum
During Air Inlet
kPa
3h.
Calculate
Regulation
Overshoot
3g.
Calculate
Regulation
Undershoot
3f.
Calculate
Fall Off
Vacuum Drop
Record
Average
Vacuum after
clusters closed
Record
Regulation
Overshoot 3d
minus 3e kPa
Record
Regulation
Undershoot
3c minus 3b kPa
Record Fall Off
Vacuum Drop
3a minus 3c
kPa
3e.
Average Vacuum
after stop of Air
Inlet kPa
Copyright © 2020 by New Zealand Milking and Pumping Trade Association. All rights reserved.
Close
Cluster(s)
Record
Maximum
Vacuum
3d.
Maximum
Vacuum
Increase kPa
To
Page 2
4
RECEIVER
7
Calculate
Vacuum
Drop Between
Regulator and
Receiver kPa
Machine in
Milking Position*
AFM at Receiver
(A1) Test Gauge
at Regulator (Vr)
Adjust AFM
2kPa below
Working Vacuum
1a
Page 2
Start Here
5
Measure Vacuum Drop In Airline
Record 4a
Vacuum at
Receiver
(kPa) and 4b
Vacuum at
Regulator
(kPa)
4c.
Record
Vacuum Drop
between
Regulator
and Receiver
(4b - 4a)
Move Test
Gauge near
Vacuum
Pumps (Vp)
4d.
Record
Vacuum near
Vacuum
Pumps
Yes
Close AFM. Pull out claw
buttons or close snap
clamps (if none then ring
long milk tubes)
Calculate
Vacuum
Drop Between
Vacuum Pumps
and
Receiver
Deactivate
pulsators
Yes
Machine Milking
Position* except
vacuum off clusters
Read Vacuum in
Milking System at
Receiver (Vm)
4e.
Record Vacuum
drop between
Vacuum Pumps
and Receiver
(4d - 4a)
Does machine
have Pulsator Stop
System?
Is
Vacuum Pump
Variable Speed
Drive?
RECEIVER
5a.
Working Vacuum in
Milking System kPa
5b.
5a minus 1a Regulation
Sensitivity kPa
REGULATOR
6
Test Regulation Sensitivity
No
No
Do you wish
to test Reserve
Vacuum off
Cluster?
EXCEPTION
FROM ISO
Do you
wish to test
Yes
Reserve Vacuum
off Cluster?
Record
minimum
Vacuum
Pump
Speed
(8b)
Reserve (Vacuum off Cluster)
Reconnect
Pulsators
No
Test to
establish a
value that
can be
revisited
during a
Short Test
used for
diagnostic or
logistical
reasons
1f.
Record vacuum on AFM
as Vacuum at minimum
Vacuum Pump Speed
Yes
Machine in
Milking
Position*
except
Vacuum off
cluster. AFM
at interceptor
(A3) and test
gauge at
Interceptor
(Vp).
INTERCEPTOR
No
6a
Close AFM.
Record
vacuum at
interceptor
(Vacuum off
Cluster)
Adjust AFM to 2kPa
below Working
Vacuum 6a
6b
Effective Reserve
Vacuum off Cluster
L/m
INTERCEPTOR
Check Vacuum Gauge Accuracy
EXCEPTION
FROM ISO
Disconnect
Regulator /
Transducer
(safety valves
may also need to
be disconnected
depending on
vacuum setting)
AFM at
interceptor (A3)
and test gauge at
regulator or near
the farm vacuum
gauge.
REGULATOR
Test to ensure
gauge is
capable of
indicating
above and
below working
vacuum.
Adjust AFM
to 5kPa
below
working
vacuum
4a
INTERCEPTOR
Read
Farm
Gauge
Read
Test
Gauge
Difference
between 7a
and 7b
7a.
Farm Gauge
Vacuum kPa
7b.
Test Gauge
Vacuum
kPa
7c.
Farm Gauge
Error 4a
minus 5 kPa
Adjust
AFM to
Working
Vacuum 4a
Read
Farm
Gauge
Read
Test
Gauge
Difference
between 7d
and 7e
7d.
Farm Gauge
Vacuum
kPa
7e.
Test Gauge
Vacuum
kPa
7f.
Farm Gauge
Error @ working
vacuum 4a
INTERCEPTOR
INTERCEPTOR
* Milking Position:
Liners plugged, vacuum on cluster, regulator(s)
or VSD Transducer connected, all controls e.g.,
ACR’s in the milking position. All vacuum
operated equipment connected.
NOTE: Some Tests require Milking Position* but
Vacuum off Cluster.
Read
Farm
Gauge
Read
Test
Gauge
Difference
between
7g and 7h
7g.
Farm
Gauge
Vacuum
kPa
7h.
Test Gauge
Vacuum
kPa
7i.
Farm Gauge
Error @ 4a
plus 5kPa
9 Vacuum Pump Exhaust Pressure
8 Test Vacuum Pump(s)
Open AFM. Isolate vacuum
pump(s) from all other parts of
the milking machine. Connect
AFM and test gauge to the
interceptor (A3 and Vp).
Adjust AFM
to Working
Vacuum 4a
plus 5kPa
Adjust Vacuum
to 50kPa
8a. Pump
Capacity
50kPa L/min
Pump 1
2
3
4
8c. Pump Speed @ 50kPa
1
2
3
4
Be aware of exposed
rotating equipment.
Replace guarding as
soon as possible.
Vacuum Pump
is liquid ring or oil
lubricated
No
Yes
Check oil or
water flow rate
if practical
Vacuum Pump Oil
or water flow rate
Drops/min or l/min
Copyright © 2020 by New Zealand Milking and Pumping Trade Association. All rights reserved.
VACUUM PUMP
EXHAUST
EXCEPTION
FROM ISO
Is Vacuum
Pump Capacity
and operation within
Standards?
No
Connect Test
Gauge to
Vacuum Pump
Exhaust (Pe)
AFM @ 50 kPa
Yes
9a. Vacuum Pump
Exhaust Pressure
kPa
To
Page 3
Air Flow Start
Adjust
Vacuum to
Working
Vacuum at
Pump Reading
1e Read AFM
Connect the Main Airline,
Receiver Airline, Pulsator Airline
and any other airlines.
Disconnect Ancillary Equipment
on Airlines. Stop or Isolate
Pulsators. Isolate the milk
system from the vacuum
system. Remove the
Regulator(s) or VSD Transducer.
Ring long milk tubes.
Record Air Flow
Start Pump
Capacity
L/min
Connect AFM to interceptor
A3. Test Gauge at Vacuum
Pump (Vp). Adjust vacuum
to Working Vacuum 1e
Read AFM.
10a. Airflow Vacuum
System Connected
L/min
10b.
Air flow start minus 10a
Vacuum System Leakage
L/min Airflow Vacuum
System Connected L/min
No
12 Cluster Air Admission
12a.
Air flow CAA
connected
L/m
INTERCEPTOR
INTERCEPTOR
Pump Capacity
at Working
Vacuum
1e L/min
Connect CAA.
Adjust
vacuum to
vacuum 1e
Read AFM
11 Automatic Cluster Removers (if present)
10 Test Airline & Milk System Leakage
Subtract
12a
from 10c
Connect Milking
System with Vacuum
off clusters.
Adjust Vacuum to 1e.
Read AFM.
ACR’s
present
Yes
Connect ACR’s.
Adjust vacuum to
vacuum 1e.
Read AFM
Disconnect
ACR’s.
No
11a.
Air Flow ACR’s
connected
10c.
Airflow Milking
System Connected
L/min
11b.
10c - 11a
ACR consumption
10d.
10a minus 10c
Milking System
Leakage L/min
13 Individual Cluster Air Admission
Reading 12b
is ≥ 4L and ≤ 12L
per cluster
(or < 35L per cluster)
for vented liners
Yes
12b.
CAA
Consumption
L/m
Do you wish
to test all clusters
individually?
Machine in
Milking
Position but
pulsators
disconnected
Yes
Connect a
Flow Meter
between the
Long Milking
Tube and
Claw
Vacuum
on
Cluster
Close Air
Vent
13a.
Record
as total
Claw Air
Admission
13b.
Record
as Air
Leakage
Subtract
13b
from
13a
Repeat
for all
Clusters
No
Do you wish to
group test clusters to
isolate an issue?
Yes
Go to
Additional
Tests
Flowchart
13c.
Air Vent
Admission
No
14 Pulsators & Ancillary Equipment
15 Test Pulsation
If readings 14b, 14d or 14f are high, the
components can be split into sub-groups
and added one sub-group at a time to isolate
leaks or excessive consumptions
Connect milk system
ancillary equipment.
Adjust AFM to
Vacuum 1e
Subtract 14a
from 12a
Connect Pulsators.
Adjust AFM to
vacuum 1e.
Subtract 14c
from 14a.
Pulsator
consumption
L/m
Connect Vacuum
System Ancillary
Equipment. Adjust
AFM to vacuum 1e.
Subtract 14e
from 14c
Vacuum System
Ancillary Equipment
Leaks L/m
14a.
Record air flow with
milk system ancillary
equipment
connected L/m
14b.
Milk System
Ancillary
Equipment
Leaks L/m
14c.
Record air flow
with pulsators
connected
L/m
14d.
Pulsator
Consumption
L/m
14e.
Record air flow with
vacuum system ancillary
equipment connected
L/m
14f.
Vacuum System
Ancillary
Equipment
Leaks L/m
Return milking
machine to
milking position
(connect
transducer or
regulator).
Remove
Airflow
Meter
Copyright © 2020 by New Zealand Milking and Pumping Trade Association. All rights reserved.
Carry out
Pulsation
Testing
15a.
Record
Maximum
Pulsation
Chamber
Vacuum in B
Phase
15b.
1a minus 15a
Pulsation
Chamber
Vacuum.
Shut Off
Machine.
Wash and
sanitise Plugs
and
Equipment.
End
Additional Tests (not required for ISO)
Releaser Milk Pump Additional Tests
Claw Air Admission Additional Test
EXCEPTION
FROM ISO
For Diagnostic or Logistic
reasons Claw Air Admission
can be divided into groups for
comparison.
Releaser Milk
Pump is
diaphragm type
Machine in Milking
Position* Except Regulator/
Transducer still
disconnected, pulsators
stopped or isolated,
Vacuum off Cluster
No
Record as Air Flow without
Claw Air Admission L/min
Record
Rate
Divide Plant into
even groups
Connect 1 group at
a time at vacuum
1e
SUM
EACH
GROUP
Draw water
through pump
Releaser Milk
Pump spm/rpm
Record rate if
single speed
controller
Connect AFM to Interceptor
(A3) Use Test Gauge at
Vacuum Pump (Vp)
Adjust AFM to Working
Vacuum 1e
Yes
Record as
Total Claw Air
Admission
L/min
Record Group 1
Record Group 2
Record Group 3
Record Group 4
Record Group 5
L/min
Copyright © 2020 by New Zealand Milking and Pumping Trade Association. All rights reserved.
Draw water
through pump
Measure vacuum
on intake for each
head
Measure vacuum
on intake at receiver.
All heads connected.
Dead End Test
each head kPa
Dead End Test all
heads kPa/bubbles
Check for bubbles
in the receiver