User Guide WinTrac™ ™6 Revision B September 2018 TK 56497-8-UG-EN Introduction This Disclaimer is subject to the terms and conditions set out in the End User License Agreement (the ”License Agreement”). The manufacturer, Thermo King® Corporation (”Thermo King”), assumes no responsibility for any act or action taken on the part of the owner or operator in the repair or operation of the products covered by this manual that are contrary to the manufacturer’s printed instructions. The use or copying of this program or user manual in violation of the License Agreement may void the License Agreement and result in termination of the License Agreement at the discretion of Thermo King Corporation. Thermo King Standard Temperature Profiles (“profiles”) are provided only as guidelines for setting up refrigerated trailers using OptiSet™ Plus. Thermo King offers these profiles to assist its valued customers and the shipping community. Every reasonable effort has been made to incorporate reliable data and information, but Thermo King does not guarantee or assume responsibility for the accuracy of all materials or for their use. These profiles should not be utilized without referring to applicable laws and regulations and/or evaluating the transit and trailer circumstances for each load. Thermo King makes no warranties or guaranties regarding the applicability of such information in specific situations, as described hereafter. Actual carrying temperatures are influenced by the placement/stacking/stowage of the manifest cargo within the refrigerated trailer, the air infiltration into the trailer, and the airflow and temperature stratification in the load. Moreover, refrigerated trailers use conditioned air from refrigeration units for cooling cargo and, as a result, there is a temperature differential between the air entering the unit (the return air) and the air exiting the unit (the discharge air). The amount of the temperature differential is a function of environmental factors, the profile settings, the airflow and the refrigeration capacity. The temperature differential, which is distributed within the trailer’s cargo space, results in the product being exposed to a range of carrying temperatures. The effect of carrying temperatures on the quality of perishable items can differ based on an array of factors, such as load mix, packaging, time in transit and storage and, in the case of horticultural items different maturities or ripeness stages, varieties, growing regions, and growing conditions. The profiles assume transit times of five days or less. WinTrac™ is a registered trademark of TK in the United States and/or other countries. Information in this document is subject to change without notice. Companies, names, and data used in any examples are fictitious unless otherwise noted. (c) Thermo King Corporation 2016. All rights reserved. All trademarks are fully acknowledged. Software License The product includes software that is licensed under a non-exclusive, non-sublicensable, terminable and limited license to use the software as installed on the product for its intended purpose. Any removal, reproduction, reverse engineering, or other unauthorized use of the software is strictly prohibited. Hacking the product or installing unapproved software may void the warranty. The owner or operator shall not reverse engineer, decompile, or disassemble the software, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation. The product may include third party software separately licensed as specified in any documentation accompanying the product or in an about screen on a mobile application or website that interfaces with the product. ©2017 Ingersoll Rand TK 56497-8-UG-EN Introduction Thermo King Machine Information Policy This Machine Information Policy applies to all Thermo King products (the “Products”). Separate terms may apply to a specific Product or when a customer has entered into an agreement with Thermo King, such as a subscription agreement for a telematics service. “Thermo King” means Thermo King Corporation, its affiliated companies and parent companies, and the affiliated companies of parent companies. “Machine Information” means information about a Product that is created by, collected by, or stored by Collection Equipment and that is shared with Thermo King. “Collection Equipment” means any device, software, app, diagnostic, service, or other product interface or connection that interacts or connects with a Product or service. Machine Information (i) may include, but is not limited to, the following types of information: model number, serial number, usage, performance, operation, location, diagnostic, software version, hardware version, configuration, setting, mode, alarm, and sensor information, but (ii) does not include Personal Information (where "Personal Information" means any information or set of information that identifies or could be used by or on behalf of Thermo King to identify an individual). A Product may include Collection Equipment, such as telematics equipment, as a standard feature and Machine Information may be collected in accordance with this Policy without activation of a telematics service or a subscription agreement. When a customer enters into a subscription agreement, Personal Information may be processed as well by Thermo King and the terms and conditions of such processing of Personal Information will be provided for in the separate subscription agreement between the customer and Thermo King and/or in the applicable privacy policy. Machine Information can be obtained by Thermo King and automatically, manually, or polled and in real time, logged or offline modes via Collection Equipment, including when a Product is connected to an authorized third party telematics service provider. Machine Information may also be collected and processed for Thermo King by business partners or third parties who process information on behalf of Thermo King using systems that interact or connect with the Product. Thermo King collects and uses Machine Information for, among other things, legitimate business reasons such as customer service; product, warranty and claims administration; product development, service, and improvement; monitoring product efficiency and performance; statistics and analytics, meeting governmental reporting and records requirements; maintenance of records; internal research; safety management; and financial and sales data management. Thermo King may provide service alerts, product offers, service offers, or other notifications based on Machine Information. Machine Information may be transferred if Thermo King sells or transfers a business or asset. Machine Information may be aggregated and the aggregated information may be disclosed to third parties or published as reports. Thermo King may disclose Machine Information if required to do so by law or to protect and defend the rights or property of Thermo King. Thermo King will take reasonable precautions to protect Machine Information in its possession from loss, misuse and unauthorized access, disclosure, alteration and destruction. Additional information or terms concerning Machine Information may be provided with a specific Product. Use of a Product serves as acceptance of the terms of this Machine Information Policy. Customers that would like to opt-out of sharing Machine Information with Thermo King or have any questions or concerns regarding the use or disclosure of Machine Information should forward such inquiries to the email address [email protected]. Thermo King will use all reasonable efforts to honor such requests as quickly as possible. Thermo King reserves the right to modify or amend this Machine Information Policy at any time. TK 56497-8-UG-EN 3 Introduction System Requirements for Application Installation To use WinTrac™, the user will need: • 2.50 GHz or faster processor. • 16GB or more RAM. • Minimum of 1 GB of available hard disk space. • Operating Systems: – Windows 7, Windows 8.1, Windows 10 • USB 2.0 or above port. • Display resolution: Best viewed in the resolution recommended by Windows for the specific PC (or 1280 x 1024). • Must have Administrative User Rights. If problems occur during the installation, contact Thermo King directly at: Thermo King Corporate Headquarters 314 West 90th Street Minneapolis, Minnesota 55420 (866) 776–2708 For European Serviced Areas (ESA) please contact your local Thermo King dealer or Regional Area Service Manager. Go to www.europe.thermoking.com and select dealer locator for your local Thermo King dealer. Or refer to the Thermo King Service Directory for contact information. For Asia Pacific (AP): (800) 820-6615 [email protected] COLD LINE: 888-887-2202 License Agreement Thank you for purchasing Thermo King WinTrac Software. It is important that you read this notice before using this Software. If you choose not to be bound by the terms and conditions of this agreement, promptly return the complete package. OWNERSHIP OF PROGRAM This Software was developed for Thermo King Corporation and Thermo King holds an exclusive license for the transport temperature control industry, with the right to sublicense. Thermo King is willing to let you use this Software under the following terms and conditions listed below. Nothing contained herein shall be deemed to convey any title or ownership interest in the Software to you. LICENSE Thermo King Corporation grants you a non-exclusive, non-transferable license to use WinTrac Software under the following conditions: • You use the Software with a single-user system at your normal place of business. • You will not transfer, lease, or otherwise rent the Software to another party. • You will not merge, modify, or reverse-engineer the licensed Software. • You acknowledge that the Software includes proprietary information of Thermo King and the developer and you will utilize your best efforts to protect the Software and the information it contains. BACK-UP COPY POLICY You have the right to load the contents of the installation media into a computer and you may copy the Software solely for back-up or archival purposes. LIMITATION OF LIABILITY WinTrac software is made available to you on an “AS IS, WHERE IS” basis, without any warranty of any kind, expressed or implied. 4 TK 56497-8-UG-EN Introduction Thermo King expressly disclaims ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND ALL WARRANTIES ARISING FROM COURSE OF DEALING, OR USAGE OF TRADE. Thermo King shall have no responsibility of any kind for: • The correctness of the Software • Your ability to use the Software or consequences of using the Software • Problems arising from defects in the Software • Claims of third parties arising from use by you • Any special, indirect, incidental, or consequential damages whatsoever. Accordingly, you shall indemnify and hold Thermo King, its subcontractors, developers, or suppliers of any tier, harmless from any loss, liability or expense arising out of your use of the Software. TERM This license agreement is in effect as long as you use the Software in your normal business. Thermo King may terminate this agreement at any time if you are in breach of any term or condition set forth herein. You may terminate your obligation of confidentiality by discontinuing use of the Software, erasing the Software from your computer and returning the Software to Thermo King. Revision History Revision A (Oct 2017) New manual. Revision B (Oct 2018) Updates throughout manual for 6.2 software release. TK 56497-8-UG-EN 5 Table of Contents Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Global Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Display Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Printer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 User Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Date Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Welcome to WinTrac Software™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Main WinTrac Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Shortcut Pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Open File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Seek Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Global Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 General Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Communications Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Database Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Display Units Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Printer Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 User Level Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Date Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Tab Switching Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 WinTrac™ Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Graphical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Sliders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Zooming the Graph Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Time of Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Symbol Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Viewing Data from Multi-Temp Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Changing the Display Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 File Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Communications Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 View Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Tabular Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Global Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Display Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Zoom In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Zoom Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Tools Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Flash Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Warm Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Cold Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 6 TK 56497-8-UG-EN Table of Contents Service Modification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Calibrate Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Setup DAS Logging Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Configure iBox™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 iBox™ Third Party Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Live Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 USB Flash Drive Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Configure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Manage Send . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Manage Retrieve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 OptiSet™ Plus Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Help Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 About . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Debugging Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 OptiSet™ Plus Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Shortcut Pane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Tab Switching Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 File Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 View Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Tools Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Navigate Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Help Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Customer Configuration Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Unit Setup Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Programmable Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Main Menu Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Hourmeter Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Programmable Hourmeters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Viewable Hourmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Cycle Sentry Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Defrost Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Access Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Language Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Unit Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 OptiSet™ Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 CargoWatch™ Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Temperature Profiles Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Manage Temperature Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Upload Temperature Profiles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Import/Export Temperature Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Generate Interchange File Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 TK 56497-8-UG-EN 7 Table of Contents Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 8 TK 56497-8-UG-EN Getting Started WinTrac contains a Global Settings window which allows the user to personalize the WinTrac software. Choose the language of your choice, temperature units, printouts, etc. Global Settings Allows the user to modify WinTrac software settings. Click on the Global Settings button on the toolbar. A window with seven tabs will appear. The user can choose between the various options on the different tabs. Click OK to apply the new settings. The settings will be retained the next time the WinTrac software is used. To cancel any changes, click Cancel. General WinTrac software allows the user to select a working language that can be set as shown below, default will be English. All WinTrac screens, messages, and printouts will reflect the language that is chosen. WinTrac software keeps diagnostic log files as it works. The files can be automatically deleted as selected below in order to conserve space. On each startup of the application, WinTrac will search and delete all the log files that are older than the selected time period. TK 56497-8-UG-EN 9 Getting Started Communications The default COM port for communications may be selected from the settings window. For SR-4 controllers, the connection status will be shown in the bottom status bar (lower left). N o t e : WinTrac automatically detects valid ports. Automatic download mode: When enabled, and the Seek Device button is clicked on the main WinTrac toolbar, WinTrac will continually check the serial port for the presence of a valid Thermo King device. On detecting a Thermo King data logger, WinTrac will automatically download all new data from the device and store this data to the appropriate file. The computer can be left unattended in this mode. Database By default, WinTrac will operate with the database created on installation of the package. However, this tab allows the user to target an alternative database located on a different drive or directory. This tab also provides the user with the option to store the unprocessed data downloaded from Thermo King data loggers. By default, WinTrac will store the unprocessed data after it has been processed and stored to the appropriate WinTrac file. Retaining the unprocessed data from your Thermo King units may be useful for diagnostic purposes. This data is stored in \download directory as *.wtd files. Display Units This tab allows the user to choose Celsius or Fahrenheit as the temperature units, and PSI, Bar, or kPa as the pressure units used throughout application. The defaults are: PSI and Fahrenheit. 10 TK 56497-8-UG-EN Getting Started Printer This tab allows the user to set the font size in printouts of temperature data in tabular reports. User Level User Level can be set as shown below, default being User. User Level affects the accessibility of advanced features. The Engineering user level requires a password. Date Format The Date Format can be set in US format or European format as shown below. TK 56497-8-UG-EN 11 Welcome to WinTrac Software™ ™ Welcome to WinTrac data logging software for Windows. WinTrac software is the easiest way to manage your data storage and display requirements for Thermo King data logging units. WinTrac is compatible with Thermo King SR-2/SR-3/SR-4, VPRS, and TouchPrint. This manual introduces you to the main features of WinTrac software, showing you how to do the most common tasks quickly and easily. This manual also contains tips and hints on using WinTrac software as efficiently as possible. This section gives you a quick overview on how to use WinTrac software, and introduces you to the main features of WinTrac. Main WinTrac Window The main WinTrac window is shown below. It consists of a Title Bar, a common Ribbon Control, a Shortcut Pane, and two Tab Switching Buttons. • Title Bar (1) - Catalogs all the available top-level commands within the WinTrac application. • Ribbon Control (2) - Contains the submenus. • Shortcut Pane (3) - Contains only icons for the most frequently used commands. • Tab Switching Buttons (4) - Used to switch between the WinTrac and OptiSet™ Plus functions. I m p o r t a n t : Icons that are grayed out indicate that they are currently disabled and cannot be operated nor selected by the user. This visually indicates to the user which actions cannot be taken in the current situation. Refer to (“WinTrac™ Functions,” p. 25) for additional details regarding the functions associated with the Title Bar and Ribbon Control. Shortcut Pane The Shortcut Pane contains eight buttons, all associated with commonly used WinTrac functions. The initial available functions are described here. Refer to (“WinTrac™ Functions,” p. 25) for details on the remaining functions. When the WinTrac application is first opened, only three icons on the Shortcut Pane are enabled. The pane can be pinned and unpinned as shown below. Click on the Unpin button to hide the Shortcut Pane. 12 TK 56497-8-UG-EN Welcome to WinTrac Software™ Click on the black tab to bring the Shortcut Pane into view. Click on the Pin button to keep the Shortcut Pane in view. Open File Used to open a file from a folder and other file management options stored in the WinTrac File Management System. WinTrac stores a file for each Thermo King unit or data logger used. These files can be organized into folders for easy management of the data. The user can organize files by type, or by customer, or even by individual trailer/container. The user can store as many files as possible in a particular folder, or even store sub-folders within a folder. This allows the user to organize WinTrac files in any way. Use the WinTrac software to perform any file management tasks on WinTrac data files. Click on Open File. TK 56497-8-UG-EN 13 Welcome to WinTrac Software™ The Open WinTrac File window appears. The user can perform all file management tasks from this window, including importing existing files into WinTrac, moving files, creating new folders, etc. WinTrac creates three folders by default, My Trailers, Imported Files, and Sample Files. The user can also access the Browse, Import, or Merge functions from this screen. • Browse - The user can view files on a local directory without importing them into the WinTrac file database. • Import - The user can import files from a local directory into the WinTrac file database. When a file is imported, it is assigned a new file name and is stored in the Imported Files folder. • Merge - Allows the user to select two or more data logger files and merge the contents. The merged files will be listed in the left view. The Open WinTrac File window also contains a toolbar, allowing the user to perform many of the common file management tasks at the touch of a button. • N e w F o l d e r : Allows the user to create a new folder for storing WinTrac data files. The folder can be renamed by typing in a new name and pressing Enter. N o t e : The user can also access this feature quickly from the pop-up menu. Click the right mouse button on a file or folder to display the pop-up menu. 14 TK 56497-8-UG-EN Welcome to WinTrac Software™ • O p e n : Expands a folder and shows its contents. The view on the left contains all the folders and files in the WinTrac file management system. The view on the right contains more detailed information on the file(s) selected. The right window can be resized if required. Select a folder and click Open. N o t e : The user can double-click the file in the left view to open a file. The user can also highlight the individual file and right-click to open. Select an item to view the expanded information to the right. With the item still highlighted, click on Open. The contents of the file can now be viewed. Select the file and click Open. N o t e : The user can also highlight the individual file and right-click to open. TK 56497-8-UG-EN 15 Welcome to WinTrac Software™ The file is opened and available to view. 16 • C u t : Select an item and click on the Cut icon. A strikethrough is added on the item and allows the user to paste the item to another location. • P a s t e : Select a new location where the strikethrough item will be placed. Click Paste. The item is placed in the new location. TK 56497-8-UG-EN Welcome to WinTrac Software™ • D e l e t e : Allows the user to select an item and permanently delete it. Select the item to be deleted and click the Delete icon. A warning message will appear. Click Yes to delete the item or No to keep the item. If Yes, the item will no longer appear. Care should be taken when using this function since entire folders (including all files) can be deleted. • R e f r e s h : Clicking on this icon will refresh the screen data. The user can refresh the screen data after performing some file management tasks to see any changes that have occurred. The user can also use the right mouse button to access a pop-up menu with additional functions as illustrated below. Highlight an item and then right-click to view the pop-up menu and available options. TK 56497-8-UG-EN 17 Welcome to WinTrac Software™ Seek Device I m p o r t a n t : The user must be in either Technician or Engineering mode to have full functionality. Used to communicate with the Thermo King Data Loggers and Units. The user can view the operating parameters of the Thermo King units, alter certain settings, and download logged data storing it to a file on a PC. Click on Seek Device. A communications progress window appears. This window indicates the type of device detected and the progress of the communications. On detecting a Thermo King device on the current COM port, WinTrac displays the settings window for the device. A typical settings window is shown below. The settings window allows the user to view the current parameters of the Thermo King unit, change the settings if required, and download any logged data from the device. 18 TK 56497-8-UG-EN Welcome to WinTrac Software™ The user can easily change the settings of the TK device from the settings window. Change the parameter(s) to the desired new setting and click on the Update Unit button located at the bottom of the settings window. WinTrac communicates with the unit and updates the setting(s). After clicking the Update Unit button, WinTrac presents the user with a list of the changes, and asks for confirmation of these changes before updating the controller. If the new setting(s) are correct, click the OK button. To cancel the changes, click the Cancel button. Successful update. Click OK. The Unit SN and Truck/Trailer ID are updated. TK 56497-8-UG-EN 19 Welcome to WinTrac Software™ The settings window allows the user to download logged data from the Thermo King data logger. Click on the Download Data button located at the bottom of the settings window. Download has been saved. Click OK. The file is added to the My Trailers folder. Global Settings Displays the Global Settings window and allows for customization of the WinTrac software for languages, communications settings, database, temperature units, printer settings, and user level. Click on Global Settings. 20 TK 56497-8-UG-EN Welcome to WinTrac Software™ A window with seven tabs will appear. The user can choose between the various options on the different tabs. Click OK to apply the new settings. The settings will be retained the next time the WinTrac software is used. To cancel any changes, click Cancel. General Tab WinTrac software allows the user to select a working language that can be set as shown below, default will be English. All WinTrac screens, messages, and printouts will reflect the language that is chosen. WinTrac software keeps diagnostic log files as it works. The files can be automatically deleted as selected below in order to conserve space. On each startup of the application, WinTrac will search and delete all the log files that are older than the selected time period. TK 56497-8-UG-EN 21 Welcome to WinTrac Software™ Communications Tab The default COM port for communications may be selected from this window. N o t e : WinTrac automatically detects valid ports. Automatic download mode: When enabled, and the Seek Device button is clicked on the main WinTrac toolbar, WinTrac will continually check the serial port for the presence of a valid Thermo King device. On detecting a Thermo King data logger, WinTrac will automatically download all new data from the device and store this data to the appropriate file. The computer can be left unattended in this mode. Database Tab By default, WinTrac will operate with the database created on installation of the package. However, this tab allows the user to target an alternative database located on a different drive or directory. This tab also provides the user with the option to store the unprocessed data downloaded from Thermo King data loggers. By default, WinTrac will store the unprocessed data after it has been processed and stored to the appropriate WinTrac file. Retaining the unprocessed data from your Thermo King units may be useful for diagnostic purposes. This data is stored in \download directory as *.wtd files. Display Units Tab This tab allows the user to choose Celsius or Fahrenheit as the temperature units, and PSI, Bar, or kPa as the pressure units used throughout application. The defaults are PSI and Fahrenheit. 22 TK 56497-8-UG-EN Welcome to WinTrac Software™ Printer Tab This tab allows the user to set the font size in printouts of temperature data in tabular reports. User Level Tab User Level can be set as shown below, default being User. The User Level affects the accessibility of advanced features. • User - User has full access to the TK Devices. User also gains access to a special Tools menu allowing access to features such as calibrating sensors, flash programming a TK device with a new version of software, setting up modes on TK devices, etc. This is the normal dealer level and the default installation mode. • Technician - User has all the access granted to Default Users, and in addition will see more information in downloaded loggers data which can be used for maintenance and diagnostics. • Engineering (Password Required) - User has all the access granted to Default Users and Technicians, and in addition will see more information in downloaded loggers data which can be used for maintenance and diagnostics. Date Format The Date Format can be set in US format or European format as shown below. TK 56497-8-UG-EN 23 Welcome to WinTrac Software™ Tab Switching Buttons The WinTrac button is selected when the WinTrac application is opened. The user can switch between the WinTrac and OptiSet Plus functions using these buttons. To switch to the OptiSet Plus functions, simply click on the OptiSet Plus button. 24 TK 56497-8-UG-EN WinTrac™ ™ Functions The WinTrac Title Bar has specific menus which provide access to such functions as file management, communications, viewing, USB Flash Drive, OptiSet Plus, and Help. It has additional functionality than the Shortcut Pane. Graphical Data Allows the viewing of data within the WinTrac data files. The user can quickly browse through the data, zooming in and out of the data views, modify graph scales with ease, and identify symbol occurrences. Sliders Using the sliders is the quickest way to select a range of data in the main graphing window. The chronological scale, located above the graphical display, shows the chronological extent of the file. The sliders are used to select a range of data. To move a slider, click on the horizontal bar of a slider, hold the mouse button depressed, and drag the slider to the desired location. Zooming the Graph Window Once the target range of data has been selected using the sliders, it is possible to zoom in on a particular trip or a particular day. N o t e : The maximum zoom resolution is two hours. Using the left mouse button, click in the graph window. Hold the mouse button and drag the mouse left or right to select the interval to be zoomed. The interval to be zoomed appears highlighted. The date and time extents (i.e., From, To) of the interval appear in the status bar. TK 56497-8-UG-EN 25 WinTrac™ Functions Release the mouse button to complete the zoom interval. WinTrac provides the user with two alternative ways to zoom the data. On the Ribbon Control, if the user clicks the Zoom In icon without selecting a zoom interval, WinTrac will automatically zoom the current display by a factor of two. The Zoom Out icon allows the user to zoom out of the current display. The Shortcut Pane can also be used to Zoom In or Zoom Out without selecting a zoom interval. 26 TK 56497-8-UG-EN WinTrac™ Functions Time of Data To determine the exact date and time occurrence of a record or event, simply position the cursor on the data - the date and time corresponding to the location of the cursor is displayed in the status bar. Symbol Identification WinTrac marks certain important events/occurrences using symbols. To identify a symbol, use the legend to the right of the screen. TK 56497-8-UG-EN 27 WinTrac™ Functions Viewing Data from Multi-Temp Units WinTrac graphs the data pertaining to the different zones of a Multi-Temperature unit on separate worksheets. In the example below, the data from zone 1 (or compartment 1) is graphed on the worksheet titled SR3 MT Zone 1. The data from zone 2 is graphed on the worksheet titled SR3 MT Zone 2 and similarly for zone 3. To switch between worksheets, simply click the relevant worksheet tab located at the lower left corner of the graph window. Changing the Display Settings The WinTrac display is fully customizable. Refer to (“Display Settings,” p. 35) for complete details. File Menu The File menu has the following functions: • O p e n F i l e : Opens a WinTrac file for viewing. • C l o s e : Closes the current open file. • I m p o r t : Imports a file into database. • B r o w s e t o f i l e s : Opens Windows Explorer at file storage. • P r i n t : Print options for currently open file. • E x i t : Exits the WinTrac application. Communications Menu Used to communicate with the Thermo King Data Loggers and Units. The user can view the operating parameters of the Thermo King units, alter certain settings, and download logged data storing it to a file on a PC. I m p o r t a n t : The user must be in either Technician or Engineering mode to have full functionality. 28 TK 56497-8-UG-EN WinTrac™ Functions • S e e k D e v i c e : Refer to (“Seek Device,” p. 18) for complete details. View Menu The View menu features the functions needed for viewing the data in WinTrac data files. The user can also personalize the display of the WinTrac data using Global Settings and Display Settings. Other functions include turning a legend on or off, zooming in, and zooming out. Tabular Data The Tabular Data option displays a text equivalent of the graphed data. The data displayed in the tabular data window can be printed or exported for importing to any standard spreadsheet package (e.g., Microsoft Excel). With a data file already opened, the user can view the graphical data presented in a tabular data view. Click on Tabular Data from the Ribbon Control or Tabular Data View from the Shortcut Pane. N o t e : Alternatively, the user can position the mouse pointer in the graph window and double click the left mouse button. This launches the tabular data window and highlights the record in the tabular data window which corresponds to the mouse pointer location on the graph. The Tabular Data View displays the text equivalent of the graphed data. The user can filter the data displayed in the tabular data window. The filter options are as follows: TK 56497-8-UG-EN • All data - This filter displays all data including headers, time logs, event logs, alarms, etc. • Alarm only - Limits the displayed data to alarm occurrences only. • Time log only - Limits the displayed data to time logs only. These are the records stored in the data logger at fixed time intervals (i.e., the Log Interval) . • Alarms and time log - Limits the displayed data to alarm occurrences and time logs only. 29 WinTrac™ Functions 30 • S e a r c h : The user can search the tabular data. Any matching keywords will be displayed in the table. • E x p o r t : The data displayed in the tabular data window can be written to a .CSV file. This file format can be imported into any standard spreadsheet package. • E x p o r t A s P D F : The user can export the data as a PDF. • E x p o r t A s H T M L : The user can export the data as HTML and can specify the output file name and path. • P r i n t : The user can print the data displayed in the tabular data window. • O p t i o n s : The user can personalize the tabular data display. Choose to enable/disable the plotting of sensors, change the sensor colors, define an average sensor, rename the sensor labels, and much more. The Display Settings window displays the Graphical display settings on the first tab and the Tabular Data display settings on the second tab. TK 56497-8-UG-EN WinTrac™ Functions To view a sensor, select the sensor by clicking in the appropriate cell in the column entitled Enabled. The sensor is enabled when the cell appears checked. Click Apply to update the display. N o t e : To view a sensor in the Tabular Data window, you must select this sensor in the Tabular Data settings. To change the color of a sensor, click on the cell indicating the sensor color. The color selection window appears. Choose the new sensor color using the left mouse button. Click Apply to update the display. To rename a sensor label, use the left mouse button and double-click the cell displaying the sensor label to be changed. The label text appears highlighted. Enter the new sensor label and click Apply to update the display. TK 56497-8-UG-EN 31 WinTrac™ Functions To re-scale a graph, select the graph to be resized from the drop-down selection box. Use the Up and Down spin buttons to adjust the minimum and maximum values of the graph scale or manually enter the values. Click Apply to update the graph with the new scale settings. 32 • C l o s e : Closes the tabular data view and returns the user to the graphical display. • T r a c e M o d e : The trace feature associates a record displayed in the tabular data window with its corresponding record in the graphical display. In Trace Mode, while scrolling through the tabular data window records, WinTrac simultaneously synchronizes the graphical display by scrolling a vertical line along the time axis. This eliminates the need to search through the contents of the tabular data window to find the records corresponding to a region of the graph. Select the Trace Mode check box and click on a row in the tabular data window. TK 56497-8-UG-EN WinTrac™ Functions WinTrac immediately highlights the corresponding record on the graph by positioning the vertical solid line in the graphical display window. The Tabular Data can also be viewed in a split screen view. Place the cursor over the ellipsis and resize the screen downward to reveal the Tabular Data. TK 56497-8-UG-EN 33 WinTrac™ Functions Global Settings Allows the user to modify WinTrac software settings. Refer to (“Global Settings,” p. 20) for details. N o t e : The same Global Settings functionality is available from the Shortcut Pane. 34 TK 56497-8-UG-EN WinTrac™ Functions Display Settings Allows the user to personalize the tabular data display. Choose to enable/disable the plotting of sensors, change the sensor colors, or define an average sensor. Click on Display Settings from either the Ribbon Control or Shortcut Pane. The Display Settings window displays the graphical display settings on the first tab and the Tabular Data display settings on the second tab. To view a sensor, select the sensor by clicking in the appropriate cell in the column entitled ‘Enabled’. The sensor is enabled when the cell appears checked. Click Apply to update the display. The sensor is enabled when the cell appears checked. Click Apply to update the display. N o t e : To view a sensor in the Tabular Data window, you must select this sensor in the Tabular Data settings. TK 56497-8-UG-EN 35 WinTrac™ Functions To change the color of a sensor, click on the cell indicating the sensor color. The color selection window appears. Choose the new sensor color using the left mouse button. Click Apply to update the display. To rename a sensor label, use the left mouse button and double-click the cell displaying the sensor label to be changed. The label text appears highlighted. Enter the new sensor label and click Apply to update the display. To re-scale a graph, select the graph to be resized from the drop-down selection box. Use the Up and Down spin buttons to adjust the minimum and maximum values of the graph scale or manually enter the values. Click Apply to update the graph with the new scale settings. N o t e : Using the elastic scales is the most efficient way to resize the graph scale. 36 TK 56497-8-UG-EN WinTrac™ Functions Use the Up and Down spin buttons to adjust the minimum and maximum values of the graph scale or use the check boxes and manually enter the values. Click the Apply button to update the graph with the new scale settings. Legend Allows the user to show or hide the legend at the right of the screen. Click on Legend to hide the legend pane. The legend on the right of the screen is hidden and the graphical display expands. To unhide the legend, click on Legend. The legend appears on the right side of the screen TK 56497-8-UG-EN 37 WinTrac™ Functions Zoom In The Zoom In feature allows the user to obtain a larger image of the graphical data being displayed. Click on Zoom In from either the Ribbon Control or Shortcut Pane. 38 TK 56497-8-UG-EN WinTrac™ Functions The user can click on Zoom In a maximum of 10 times to get the desired result. Zoom Out The Zoom Out feature allows the user to obtain a smaller image of the graphical data being displayed. Click on Zoom Out from either the Ribbon Control or Shortcut Pane. TK 56497-8-UG-EN 39 WinTrac™ Functions The user can click on Zoom Out a maximum of 10 times to get the desired result. 40 TK 56497-8-UG-EN WinTrac™ Functions Tools Menu The Tools menu allows the user perform tasks such as calibrating sensors, flash programming a TK device with a new version of software, setting up modes on TK devices, etc. To access the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. Flash Load N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. Allows the user to perform software updates to the various components in the system. When Base Controller and/or HMI Control Panel flash load files are downloaded from the Thermo King iService website, the flash load files are downloaded as a *.ZIP file. When flash load files for these applications are unzipped, the following files will be included: • SR-2/SR-3: The traditional *.mXX and *.cXX files will be unzipped. These two files are for use when flash loading a unit in the traditional manner by using a Data Cable to connect the unit to a computer equipped with WinTrac. N o t e : Both the *.mXX and *.cXX files must be present in order to perform a flash load using a Data Cable, even though only one of them is shown by WinTrac. • SR-3 Only: A *.FLA file will also be unzipped. This file is for use when flash loading an SR-3 unit using a WinTrac configured USB Flash Drive. The Flashload Directory on the configured USB Flash Drive contains sub-directories for HMI and flash load *.FLA/ files. The *.FLA/ files must be placed in the correct directory on the flash drive using either the WinTrac Manage Send/Retrieve feature or Windows Explorer. • SR-4 Only: A *.FLI file will be unzipped. This file is for use when flash loading an SR-4 unit using a WinTrac configured USB Flash Drive or Mini USB Cable. The Flashload Directory on the configured USB Flash Drive contains sub-directories for HMI and flash load *.FLI/ files. The *.FLI/ files must be placed in the correct directory TK 56497-8-UG-EN 41 WinTrac™ Functions within the /ICON/folder on the flash drive using either the WinTrac Manage Send/Retrieve feature or Windows Explorer. Base Controller and HMI Control Panel software is available on the Thermo King TSA Info Central website. Go to: http://www.thermoking.com/tk/index.asp Choose iService Login. After logging in, choose either TSA Info Central or EMEA Info Central as applicable. • For TSA Info Central: Select Home > Software and Downloads > Truck and Trailer > Microprocessors > Trailer Microprocessor Updates. • For ESA/EMEA InfoCentral: Select Home > Software Updates > Microprocessors and then the applicable controller and unit configuration. Base Controller Software - The file name for the *.ZIP file containing both the traditional .mXX and .cXX files and the *.FLA/*.FLI file is (Example) “Micro Code Xxxx Update for the SR-3 Single Temp Base Controller.zip”. Double click this file to download the software. Highlight the zip file(s) and extract all files. HMI Control Panel Software - The file name for the *.ZIP file containing both the traditional .mXX and .cXX files and the *.FLA/*.FLI file is (Example) “Micro Code Xxxx Update for the SR-3 HMI Control Panel.zip”. Double click this file to download the software. Highlight the zip file(s) and extract all files. I m p o r t a n t : When flash loading from a computer, connect the Data Cable to the ServiceWatch port to update the controller and the CargoWatch port to update the HMI for SR-3, or connect a Mini USB Cable to the gray USB port (J11) on the Base Controller for SR-4. A USB Flash Drive can be used to update both the controller and HMI. Controller Flash Load • For SR-3, verify the Data Cable is connected to the ServiceWatch port on the Control Panel. • For SR-4, verify the Mini USB Cable is connected to the gray USB port (J11) on the Base Controller. Click on the Flash Load Icon to begin the process for flash loading the Base Controller. Select flash load option and click OK. Navigate to your local directory and locate the flash load file that was downloaded from Info Central. Highlight the file and click Open. Below are examples of SR-3 and SR-4 files. Figure 1. 42 SR-3 TK 56497-8-UG-EN WinTrac™ Functions Figure 2. SR-4 Click Yes to continue. N o t e : The example below illustrates SR-3 (SR-4 similar). Click OK. N o t e : If the flash loading process fails, WinTrac will prompt you to re-try. Check all power and communications connections before re-trying as this may have led to the flash load failure. N o t e : If flash load re-try still fails, try powering down your device and powering it up again before retrying. This may help WinTrac to find the device when starting the flash load process. HMI Flash Load • For SR-3, verify the Data Cable is connected to the CargoWatch port on the Control Panel. • For SR-4, verify the Mini USB Cable is connected to the gray USB port (J11) on the Base Controller. Click on the Flash Load Icon to begin the process for flash loading the HMI. Select flash load option and click OK. Navigate to your local directory and locate the flash load file that was downloaded from Info Central. Highlight the file and click Open. Below are examples of SR-3 and SR-4 files. TK 56497-8-UG-EN 43 WinTrac™ Functions Figure 3. SR-3 Figure 4. SR-4 Click Yes to continue. The flash load process may take some time. N o t e : The example below illustrates SR-3 (SR-4 similar). Click OK. N o t e : If the flash loading process fails, WinTrac will prompt you to re-try. Check all power and communications connections before re-trying as this may have led to the flash load failure. N o t e : If flash load re-try still fails, try powering down your device and powering it up again before retrying. This may help WinTrac to find the device when starting the flash load process. Warm Restart N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. A warm restart reboots the controller or data logger. The user will not lose any logged data or any unit settings. A warm restart has the same affect as powering off the TK device and switching it back on again. Click on the Warm Restart icon. WinTrac will search for a TK device and ask to confirm the actions before restarting the device. Click Yes to continue. 44 TK 56497-8-UG-EN WinTrac™ Functions Click Yes to continue. WinTrac will confirm that the TK device was restarted. Click OK. Cold Restart N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. A cold restart will reset all settings back to default. Any logged data on your data logger or controller will remain. Click on the Cold Restart icon. WinTrac will search for a TK device and ask to confirm the actions before restarting the device. Click Yes to continue. TK 56497-8-UG-EN 45 WinTrac™ Functions Click Yes to continue. WinTrac will confirm that the TK device was restarted. Click OK. Service Modification NOTICE Equipment Operation! Use of the Service Modification feature may alter the operation of the Thermo King refrigeration unit. It is recommended that this feature be used by trained Thermo King service personnel only. N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. Units based on Thermo Kings Global Data Table (DAS, HMI, iBox, SR-2/SR-3/SR-4, etc.) can be directly configured from WinTrac using the Service Modification facility. Use of the Service Modification feature may alter the operation of the Thermo King refrigeration unit. We recommend this feature be used by trained TK Service Personnel only. 46 TK 56497-8-UG-EN WinTrac™ Functions A .CSV format file containing the desired settings can be uploaded into the unit. To accomplish this, select the Service Modification icon. WinTrac will ask for the name of the modification file to send to the unit. Once the file is selected, WinTrac checks the connections to the unit and, if valid, will send the modification data to the unit and check that the changes were accepted. Click on Service Modification to begin. Verify you want to continue by clicking Yes. Select the required .CSV file and click Open. WinTrac checks for controller connection and will also validate the .CSV file. Click Yes to continue with the Service Modification. TK 56497-8-UG-EN 47 WinTrac™ Functions WinTrac will perform a warm restart of the TK device. Click Yes to continue. Service Modification will show success or failure. If any failure occurs, contact Thermo King Service personnel to check and resolve the problem. Click OK. 48 TK 56497-8-UG-EN WinTrac™ Functions Calibrate Sensor N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. The user can calibrate the sensors on the DAS data logger using the WinTrac software. The user can choose either ice-bath calibration or sensor-grade calibration for DAS data logger. • I c e - B a t h C a l i b r a t i o n : WinTrac will calibrate the sensor and inform you when calibration is complete. If the Sensor reading is too far from 0°C (32°F), WinTrac will inform you that the chosen sensor is out of range. This also prevents the accidental calibration of a different sensor. • G r a d e d - S e n s o r C a l i b r a t i o n : Choose the required sensor grade (it should be stamped on the sensor). WinTrac will calibrate the sensor and inform you when calibration is complete. Setup DAS Logging Modes N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. When main power is removed from the DAS data logger, the DAS is capable of running in two different logging modes in order to continue logging yet conserve the battery of your Thermo King unit. When main power is removed from the DAS, it enters into Countdown Mode. The DAS continues to log as normal when in this mode. The user can set the duration of Countdown Mode from WinTrac in the logging modes window. Once countdown mode has expired, DAS enters Conservative Mode. In this mode, the DAS remains in sleep mode and only powers-up each logging interval. The DAS then performs a log and goes back into sleep mode. The user can adjust the duration of Conservative Mode by setting the number of logs performed in Conservative Mode from the logging modes window. Configure iBox™ ™ N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. N o t e : Not applicable for TK BlueBox. WinTrac can be used to configure iBox settings. By selecting Configure iBox from the Tools menu with an iBox connected, the user will be able to change various settings on the iBox, including the serial number and protocol selection. TK 56497-8-UG-EN 49 WinTrac™ Functions iBox™ ™ Third Party Communications N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. WinTrac now supports sending iBox Third Party Communications. Select the iBox Third Party Communications icon from the Tools menu. A window displays that will allow the user to query various settings on the unit. Verify the communication cable is connected to the ‘3rd Party’ RS232 port before attempting these commands. 50 TK 56497-8-UG-EN WinTrac™ Functions Live Data N o t e : To access this feature from the Tools menu, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. This feature allows the user to view SR-4 Single Temperature unit data. Select the Live Data icon from the Tools menu to view data from the SR-4 Single Temperature unit. Return Air, Discharge Air, Battery Voltage, Engine Temperature, Engine RPM, Coil temperature, Suction Pressure, and Discharge Pressure will be displayed in graph/gauge form and are updated in five second intervals. The graphical tiles can be reordered and enlarged. Setpoint, Ambient, Oil Pressure, Oil Level, ETV Position, and Condenser and Evaporator fan states are listed in text in the right pane and are also updated in five second intervals. USB Flash Drive Menu I m p o r t a n t : Only a USB 2.0 flash drive can be used. N o t e : Illustrations shown are for SR-3 (SR-4 similar). When a properly configured USB 2.0 flash drive is connected to the front panel USB connector, the flash drive user interface is shown on the HMI Control Panel. The USB flash drive provides CargoWatch and ServiceWatch Data Logger downloads, flash loading HMI Control Panel and Base Controller software, and sending and retrieving OptiSet Plus files. Using a properly configured and enabled flash drive, the following functions may be available: TK 56497-8-UG-EN • Download the ServiceWatch Data Logger • Download the CargoWatch Data Logger • Flash load Base Controller Software • Flash load HMI Control Panel Software • Send OptiSet Plus Files • Retrieve OptiSet Plus Files 51 WinTrac™ Functions Configure A USB 2.0 flash drive must be configured using the WinTrac application before the flash drive can be used with truck and trailer units equipped with a USB Communications Port. When the USB flash drive is configured, only empty file folders are created on the flash drive. The files required for flash loads and/or OptiSet Plus must be placed in the appropriate flash drive folders. Insert the USB flash drive into a USB Port on a computer. If a USB flash drive is not connected to a computer, the Configure, Manage Send, and Manage Retrieve functions will not be available to use. Click Configure. If the USB flash drive is already configured, the user will receive a message as shown below. Click Yes to continue. If the USB flash drive has not been previously configured, a new window pops up which allows the user to enter company name and author name. Type in the Company Name and Author Name. The UFD Serial Number and Creation Date is captured automatically by the system. • Download Operations - Select options CargoWatch, ServiceWatch as applicable. • Flashload Operations - Select options HMI, Multi-Temp Controller, Single Temp Controller as applicable. • OptiSet Plus Operations - Select options Send and/or Retrieve as applicable. After selecting options, click Next. 52 TK 56497-8-UG-EN WinTrac™ Functions Click Next. Click Next again. Review selection(s). If any changes are needed, click Previous to go back and update. Click Finish to accept. TK 56497-8-UG-EN 53 WinTrac™ Functions The USB flash drive is now configured. Click OK. Manage Send Select the files which need to be sent to the USB flash drive. The maximum number of files selected in a single directory is 10 in the USB flash drive. Click on Manage Send, a new window will open. N o t e : The USB flash drive must be configured prior to proceeding. Click on the Right Arrow icon to move the files from the PC to the USB flash drive. Click Browse under either FLASHLOAD or OPTISET PLUS to bring up a window to search for specific files not already listed. To remove/deselect files from the selection, click on the red X. 54 TK 56497-8-UG-EN WinTrac™ Functions If Browse under FLASHLOAD was selected, click on the applicable radio button to select the required operation. Click Ok to view the file(s). Select file(s) to send. Click Open to continue. TK 56497-8-UG-EN 55 WinTrac™ Functions Click Next or Review & Finish after selection(s). Review selection(s). If any changes are needed, click Previous to go back and update. Click Finish to accept. Click OK. 56 TK 56497-8-UG-EN WinTrac™ Functions Manage Retrieve Select the files which you need to retrieve from the USB flash drive. The maximum number of files selected in a single directory is 10. Click on Manage Retrieve, a new window will open. N o t e : The USB flash drive must be configured prior to proceeding. Click on the Left Arrow icon to move the files from the USB flash drive to the PC. To remove/ deselect files from the selection, click on the red X. The selected file is moved to the PC as shown below. Click Next or Review & Finish. Review selection(s). If any changes are needed, click Previous to go back and update. Click Finish to accept. TK 56497-8-UG-EN 57 WinTrac™ Functions Click OK. OptiSet™ ™ Plus Menu OptiSet Plus provides custom temperature control based on particular commodities. The set of temperature control parameters for a given commodity is called a temperature profile. Refer to (“Temperature Profiles Menu,” p. 71) for information on creating temperature profiles. The OptiSet Plus application produces a file called an interchange file that can be uploaded into the Thermo King unit with WinTrac. • S e n d O p t i S e t P l u s : Use this feature to send an interchange file. WinTrac will ask for the name of the interchange file to send to the TK unit. WinTrac will check to verify that the interchange file being uploaded is suitable for the target system. • R e t r i e v e O p t i S e t P l u s : The user can retrieve the current OptiSet Plus configuration from the controller, and save it to the PC in a file that can be opened using the OptiSet Plus PC application. Simply select this feature and follow the on-screen instructions. This function is useful for validating and saving a unit's current OptiSet Plus configuration prior to making changes. • R e s e t O p t i S e t P l u s : This feature will send an OptiSet Plus reset to the ServiceWatch device. • O p t i S e t P l u s : This feature will take the user to the OptiSet Plus functions of WinTrac. This has the same functionality as the bottom Tab Switching OptiSet Plus Button. Help Menu The Help menu features User Guide, About, and Debugging Options. It allows the user to access the online User Guide, view the WinTrac version and release information, and view the software debugging options. User Guide The User Guide familiarizes the user with the main features of the WinTrac software, presenting information on how to accomplish the most common functions quickly and easily. It also contains tips and hints on using the WinTrac software as efficiently as possible. About Allows the user to view the WinTrac version and release information. Click the About icon to open the information dialogue box. Click OK to return to the main screen. 58 TK 56497-8-UG-EN WinTrac™ Functions Debugging Options WinTrac software has the ability to have debug logs that contain module level debugging/trace information. The level of information logged is based on the selected Message level. The software will log time stamp, file name/method name, and a message for each debug/trace message. TK 56497-8-UG-EN • Error - Information related only to errors. • Warning - Information related to Warning and Errors. • Information - Information related to Informational, Warning, and Errors. • TraceMessages - Information related to all. 59 OptiSet™ ™ Plus Functions OptiSet Plus allows the user to create, send, and retrieve OptiSet Plus configurations from the unit. It also allows the user to create and manage temperature profiles. The main OptiSet Plus window is shown below. It consists of a Title Bar (1), a common Ribbon Control (2), a Shortcut Pane (3), and two Tab Switching Buttons (4) used to switch between the WinTrac and OptiSet Plus functions. The Title Bar has specific menus which provide access to such functions as file management, viewing, navigation, and Help. It has additional functionality than the Shortcut Pane. N o t e : Icons that are grayed out indicate that they are currently disabled and cannot be operated nor selected by the user. This visually indicates to the user which actions cannot be taken in the current situation. Shortcut Pane The left Shortcut Pane contains five menu icons, all associated with commonly used OptiSet Plus functions. The available functions are described here. When the OptiSet Plus application is first opened, only the Customer Configuration Menu on the Shortcut Pane is enabled. Once Customer Configuration is loaded or completed, the other menus will be available. C u s t o m e r C o n f i g u r a t i o n M e n u : Access the Customer Configuration Menu. U n i t S e t u p M e n u : Access the Unit Setup Menu. C a r g o W a t c h S e t u p M e n u : Access the CargoWatch Setup Menu. 60 TK 56497-8-UG-EN OptiSet™ Plus Functions T e m p e r a t u r e P r o f i l e s M e n u : Access the Temperature Profiles Menu. G e n e r a t e I n t e r c h a n g e F i l e M e n u : Access the Generate Interchange File Menu. Tab Switching Buttons The user can switch between the WinTrac and OptiSet Plus functions using these buttons. To switch to the WinTrac functions, simply click on the WinTrac button. File Menu The File menu features all the functions needed to perform file management tasks, including creating a new OptiSet Plus configuration file, opening and saving a file, and exiting the application. • N e w : Creates a new OptiSet Plus configuration file. • O p e n : Opens an existing OptiSet Plus configuration file. • S a v e : Saves the active OptiSet Plus configuration file. • S a v e A s : Saves the active OptiSet Plus configuration file with a new name. • R e c e n t : Opens a recently used OptiSet Plus configuration file • E x i t : Exits the WinTrac application. View Menu The View menu has the following functions: • G l o b a l S e t t i n g s : Opens the Global Settings Options. Refer to (“Global Settings,” p. 20) for complete details. • C u s t o m e r I n f o S e t u p : Opens OptiSet Plus Customer Information Setup. Previously entered information can be edited or new information can be added. N o t e : The user must enter Customer Info details in order to save the OSP file. TK 56497-8-UG-EN 61 OptiSet™ Plus Functions Tools Menu The Tools menu allows the user perform various OptiSet Plus tasks. To access the Tools menu from OptiSet Plus, press 'Ctrl' + 'Shift' + 'T' keys simultaneously. The Tools menu will appear in the Title Bar. • I m p o r t T e l e m a t i c s F i l e : The user will be prompted to select the XML file to import. Choose a file name and save location for the OSP file to be created. An OSP file will be created based on the selected telematics XML file. • E x p o r t T e l e m a t i c s F i l e : The user will be prompted to select the OSP file to export. Choose a file name and save location for the XML file to be created. An XML file will be created based on the selected OSP file. • S e n d O p t i S e t P l u s : Use this feature to send an interchange file. WinTrac will ask for the name of the interchange file to send to the TK unit. WinTrac will check to verify that the interchange file being uploaded is suitable for the target system. • R e t r i e v e O p t i S e t P l u s : The user can retrieve the current OptiSet Plus configuration from the controller, and save it to the PC in a file that can be opened using the OptiSet Plus PC application. Simply select this feature and follow the on-screen instructions. This function is useful for validating and saving a unit's current OptiSet Plus configuration prior to making changes. • R e s e t O p t i S e t P l u s : This feature will send an OptiSet Plus reset to the ServiceWatch device. Navigate Menu The Navigate menu has essentially the same functions as the Shortcut Pane with the exception of a WinTrac button. 62 • C u s t o m e r C o n f i g u r a t i o n : Switch to the Customer Configuration Menu. Refer to (“Customer Configuration Menu,” p. 63) for complete details. • U n i t S e t u p : Switch to the Unit Setup Menu. Refer to (“Unit Setup Menu,” p. 64) for complete details. • C a r g o W a t c h S e t u p : Switch to the Cargo Watch Setup Menu. Refer to (“CargoWatch™ Setup Menu,” p. 69) for complete details. • T e m p e r a t u r e P r o f i l e s : Switch to the Temperature Profiles Menu. Refer to (“Temperature Profiles Menu,” p. 71) for complete details. TK 56497-8-UG-EN OptiSet™ Plus Functions • G e n e r a t e I n t e r c h a n g e F i l e / R e p o r t : Switch to the Generate Interchange File Menu. Refer to (“Generate Interchange File Menu,” p. 79) for complete details. • W i n T r a c : Returns the user to the WinTrac functions. Help Menu The Help menu features Help File, About, and Debugging Options. It allows the user to access the User Guide, view the WinTrac version and release information, and view the software debugging options. Refer to (“Help Menu,” p. 58) for complete details. Customer Configuration Menu OptiSet Plus begins at the Customer Configuration screen. The user must complete the following fields: TK 56497-8-UG-EN • Author Name - Enter the name of the author of the configuration file to be created in this field. • Customer Name - Enter the name of the customer for the configuration file to be created in this field. • Self - Select this button to enter the Customer Name previously entered in Customer Information Setup. Refer to (“View Menu,” p. 61). • Vehicle Category - Select the vehicle category and the list of unit models are displayed in the Unit Model drop down menu. • Controller Software Revision - Select the correct controller software revision for the unit controller from the drop down menu. • HMI Software Revision - Select the correct HMI software revision for the unit controller from the drop down menu. • Unit Model - Select the appropriate Unit Model from the drop down menu. • Fresh Frozen Range - Choices are 15°F (-9°C) or 24°F (-4°C). All setpoints less than or equal to this value will be treated as Frozen Ranges. All setpoints greater than this value will be treated as Fresh Ranges. • ETV (Electronic Throttle Valve) - Specify if the unit is equipped with the optional Electronic Throttle Valve (ETV). If the unit is equipped with an ETV, this feature should be set to Enabled. If the unit is not equipped with an ETV, this feature should be set to Disabled. • Comments - Enter any necessary comments. This field does not have to be completed in order to proceed. 63 OptiSet™ Plus Functions When the mandatory fields have been completed, all top menu and side toolbar options are enabled. The user can Save the configuration file or click Next to proceed to Unit Setup. Unit Setup Menu Allows the user to setup the Thermo King unit in terms of Programmable Features, Main Menu Configuration, Hourmeter Setup, Cycle Sentry Setup, Defrost Setup, Access Code, Language Setup, Unit Configuration, and OptiSet Plus. 64 TK 56497-8-UG-EN OptiSet™ Plus Functions • B o t t o m T o o l b a r : This is the row of button commands along the bottom of the OptiSet Plus interface. – Reset - Resets all of the OptiSet Plus values to the default unit settings. – Back - Switches to the previous OptiSet Plus menu screen. – Next - Switches to the next OptiSet Plus menu screen. Programmable Features Allows the user to modify the Programmable Features settings. N o t e : Field selections may affect the availability of other fields. Refer to the applicable Microprocessor Based Control System Diagnostic Manual for a complete list of available features. Main Menu Configuration Allows the user to customize the HMI. N o t e : Field selections may affect the availability of other fields. Refer to the applicable Microprocessor Based Control System Diagnostic Manual for a complete list of available features. Hourmeter Setup Allows the user to program or enable hourmeter viewing on the HMI. TK 56497-8-UG-EN 65 OptiSet™ Plus Functions Programmable Hourmeters Allows the user to enable or disable Total Run Time Reminder Hours, Engine Run Time Reminder Hours, Pretrip Reminder Hours, Controller Power On Hours, and Engine Run Time Service Due Date. • • • • • T o t a l R u n T i m e R e m i n d e r # 1 H o u r s : Allows the user to enable or disable Total Run Time Reminder #1 Hours Hourmeter. Also allows the user to set the meter limit and the elapsed time of the hourmeter. Default option is Disabled. – M e t e r L i m i t : When enabling the option, the user can enter a value in whole hours and default is 100 hours. – E l a p s e d T i m e : When enabling the option, the user can enter a value in whole hours and default is 0 hours. T o t a l R u n T i m e R e m i n d e r # 2 H o u r s : Allows the user to enable or disable Total Run Time Reminder #2 Hours Hourmeter. Also allows the user to set the meter limit and the elapsed time of the hourmeter. Default option is Disabled. – M e t e r L i m i t : When enabling the option, the user can enter a value in whole hours and default is 100 hours. – E l a p s e d T i m e : When enabling the option, the user can enter a value in whole hours and default is 0 hours. C o n t r o l l e r P o w e r O n H o u r s : Allows the user to enable or disable Controller Power On Reminder Hours Hourmeter. Also allows the user to set the meter limit and the elapsed time of the hourmeter. Default option is Disabled. – M e t e r L i m i t : When enabling the option, the user can enter a value in whole hours and default is 100 hours. – E l a p s e d T i m e : When enabling the option, the user can enter a value in whole hours and default is 0 hours. P r e t r i p R e m i n d e r H o u r s : Allows the user to enable or disable Pretrip Reminder Hours Hourmeter. Also allows the user to set the meter limit and the elapsed time of the hourmeter. Default option is Disabled. – M e t e r L i m i t : When enabling the option, the user can enter a value in whole hours and default is 100 hours. – E l a p s e d T i m e : When enabling the option, the user can enter a value in whole hours and default is 0 hours. E n g i n e R u n T i m e R e m i n d e r # 1 H o u r s : Allows the user to enable or disable Engine Run Time Reminder #1 Hours Hourmeter. Also allows the user to set the meter limit and the elapsed time of the hourmeter. Default option is Disabled. – 66 M e t e r L i m i t : When enabling the option, the user can enter a value in whole hours and default is 1500 hours. TK 56497-8-UG-EN OptiSet™ Plus Functions – • • E l a p s e d T i m e : When enabling the option, the user can enter a value in whole hours and default is 0 hours. E n g i n e R u n T i m e R e m i n d e r # 2 H o u r s : Allows the user to enable or disable Engine Run Time Reminder #2 Hours Hourmeter. Also allows the user to set the meter limit and the elapsed time of the hourmeter. Default option is Disabled. – M e t e r L i m i t : When enabling the option, the user can enter a value in whole hours and default is 100 hours. – E l a p s e d T i m e : When enabling the option, the user can enter a value in whole hours and default is 0 hours. E n g i n e R u n T i m e S e r v i c e D u e D a t e E n a b l e d : Allows the user to enable or disable Engine Run Time Service Due Date. Also allows the user to set the due date. Default option is Disabled. When enabling the option, the user can set the date using the calendar icon. Viewable Hourmeters Allows the user to enable or disable Total Hours, Total Run Time Hours, Engine Hours, Total Run Time Reminder #1 Hours, Total Run Time Reminder #2 Hours, Controller Power On Hours, Pretrip Reminder Hours, Engine Run Time Reminder #1 Hours, Engine Run Time Reminder #2 Hours. N o t e : Field selections may affect the availability of other fields. TK 56497-8-UG-EN • T o t a l H o u r s : Allows the user to enable or disable viewing on the HMI of the Total Hours Hourmeter. • T o t a l R u n T i m e H o u r s : Allows the user to enable or disable viewing on the HMI of the Total Unit Run Hours Hourmeter. • E n g i n e H o u r s : Allows the user to enable or disable viewing on the HMI of the Engine Hours Hourmeter. • T o t a l R u n T i m e R e m i n d e r # 1 H o u r s : Allows the user to enable or disable viewing on the HMI of the Total Run Time Reminder #1 Hours Hourmeter. • T o t a l R u n T i m e R e m i n d e r # 2 H o u r s : Allows the user to enable or disable viewing on the HMI of the Total Run Time Reminder #2 Hours Hourmeter. • C o n t r o l l e r P o w e r O n H o u r s : Allows the user to enable or disable viewing on the HMI of the Controller Power On Hours Hourmeter. • P r e t r i p R e m i n d e r H o u r s : Allows the user to enable or disable viewing on the HMI of the Pretrip Reminder Hours Hourmeter. • E n g i n e R u n T i m e R e m i n d e r # 1 H o u r s : Allows the user to enable or disable viewing on the HMI of the Engine Run Time Reminder #1 Hours Hourmeter. • E n g i n e R u n T i m e R e m i n d e r # 2 H o u r s : Allows the user to enable or disable viewing on the HMI of the Engine Run Time Reminder #2 Hours Hourmeter. 67 OptiSet™ Plus Functions Cycle Sentry Setup Allows the user to modify the Cycle Sentry settings. N o t e : Field selections may affect the availability of other fields. Refer to the applicable Microprocessor Based Control System Diagnostic Manual for a complete list of available features. Defrost Setup Allows the user to modify the Defrost settings. N o t e : Field selections may affect the availability of other fields. • D e f r o s t I n t e r v a l i n R a n g e w i t h F r e s h S e t p o i n t : Allows the user to select the maximum interval between defrosts if operating with a fresh setpoint and the return air temperature is within range of the setpoint when the interval expires. • D e f r o s t I n t e r v a l N o t i n R a n g e w i t h F r e s h S e t p o i n t : Allows the user to select the maximum interval between defrosts if operating with a fresh setpoint and the return air temperature is not within range of the setpoint when the interval expires. • D e f r o s t I n t e r v a l i n R a n g e w i t h F r o z e n S e t p o i n t : Allows the user to select the maximum interval between defrosts if operating with a frozen setpoint and the return air temperature is within range of the setpoint when the interval expires. • D e f r o s t I n t e r v a l N o t i n R a n g e w i t h F r o z e n S e t p o i n t : Allows the user to select the maximum interval between defrosts if operating with a frozen setpoint and the return air temperature is not within range of the setpoint when the interval expires. • M a x i m u m D e f r o s t D u r a t i o n : Allows the user to select the maximum duration that the unit can be in defrost. Access Code Allows the user to require and set a security code to enter the HMI’s Guarded Access. Enter any 1 to 4 digit number from 1 to 9999. Language Setup Allows the user to configure which languages will be available on the HMI. Multiple languages can be enabled. If so, a screen will appear asking the operator to select the display language. The languages available are dependent on the software revision in the HMI control panel. English is included in all versions. Only one software revision can be installed, and only the languages supported in that revision are available. Depending on unit configuration the following languages may be enabled or disabled: 68 TK 56497-8-UG-EN OptiSet™ Plus Functions N o t e : For HMI Software Revision 6830 and later, all of these languages are available for selection with HMI availability. Arabic French Polish Bulgarian German Portuguese Chinese (Mandarin) Greek Romanian Czech Hebrew Russian Danish Hungarian Spanish Dutch Italian Swedish English Japanese Turkish Finnish Norwegian English is always ENABLED by default. When an available language is ENABLED, it will be viewable on the HMI. Multiple languages can be ENABLED. If so, a screen will appear asking the operator to select the display language. Unit Configuration Allows the user to modify the Hardware Configuration settings. The user can determine the unit’s configuration in the fields as shown below: N o t e : Field selections may affect the availability of other fields. Refer to the applicable Microprocessor Based Control System Diagnostic Manual for a complete list of available features. OptiSet™ ™ Plus N o t e : This feature is enabled for Single Temperature Trailer platforms only. Allows the user to determine which type of OptiSet Plus profiles are allowed to be used. • T e m p e r a t u r e P r o f i l e S e l e c t i o n : Allows the user to select which temperature profile types will be available in the HMI. CargoWatch™ ™ Setup Menu N o t e : This feature enabled for Trailer platforms only. Allows the user to set the CargoWatch in terms of Logging Interval, Countdown Timer, Conservative Log Count, and SOT on Setpoint Change. N o t e : Field selections may affect the availability of other fields. TK 56497-8-UG-EN 69 OptiSet™ Plus Functions • L o g g i n g I n t e r v a l : Allows the user to select the time interval at which timed logs will take place. • C o u n t d o w n T i m e r : Allows the user to select the amount of time to continue logging after the unit has been powered off. Available options for selection are: x Hours where x is any value from 0 to 96. • C o n s e r v a t i v e L o g C o u n t : Allows the user to select the number of times to perform a log after the unit has been powered off and the Countdown timer has expired. Available options for selection are: Integers from 0 to 400. • S O T O n S e t p o i n t C h a n g e : Allows the user to enable the logging of a Start of Trip header each time the setpoint is changed. • A u t o m a t i c S O T a t M i d n i g h t : Allows the user to enable the logging of a Start of Trip header at midnight. • L o g S e n s o r s : These are the six CargoWatch sensors. Each tab allows the user to configure the specific settings for each log sensor. – S e n s o r L o g g i n g : Allows the user to enable or disable the logging of Log Sensor. – I n d e p e n d e n t S e n s o r : N a m e : Allows the user to assign a text name to the log sensor to be shown on handheld printer reports. Available options for selection are: Return Air Other Return Air Discharge Air Other Discharge Air Spare Return Air Other Spare Return Air Spare Discharge Air Other Spare Discharge Air USDA 1 USDA 2 USDA 3 Spare USDA 1 Spare USDA 2 Spare USDA 3 Spare 70 Other Other Spare Front Rear Side Right Side Left Side Spare Front Spare Rear Spare Side Spare Right Side Spare Left Side Fresh Frozen Chilled Dry Spare Fresh Spare Frozen Spare Chilled Spare Dry Ambient Spare Ambient Log Sensor 1 (Default) Log Sensor 2 Log Sensor 3 Log Sensor 4 Log Sensor 5 Log Sensor 6 – O u t o f R a n g e C h e c k i n g : Allows the user to enable logging of Alarm Codes 150, 151, or 152 due to the log sensor going out of the selected range versus setpoint. – S e n s o r A v e r a g i n g : Allows the user to enable or disable the logging of the averaged log sensor. TK 56497-8-UG-EN OptiSet™ Plus Functions • D i g i t a l I n p u t : These are the three CargoWatch digital inputs. Each tab allows the user to configure the specific logging settings for each input. – • D o o r O p e n L o g g i n g : Allows the user to enable logging of the door switch connected to digital input. B o t t o m T o o l b a r : This is the row of button commands along the bottom of the OptiSet Plus interface. – Reset - Resets all of the OptiSet Plus values to the default unit settings. – Back - Switches to the previous OptiSet Plus menu screen. – Next - Switches to the next OptiSet Plus menu screen. Temperature Profiles Menu N o t e : This feature is enabled for Single Temperature Trailer platforms only. A temperature profile is a defined set of unit settings that define the temperature control algorithm and associated settings. Temperature profiles are designed to achieve maximum cargo preservation while optimizing unit performance with simple, easy-to-understand steps. OptiSet Plus contains a full library of standard and pre-defined temperature profiles for transporting commodities. Temperature profiles can be uploaded from the library, modified and saved, imported, and exported. If an existing temperature profile is modified, it must be saved using a different name provided by the user. If any temperature profile is modified or created from scratch, it is done so at the customers own risk and Thermo King cannot be liable if the results are unsatisfactory. There are three tabs to assist with Temperature Profiles: TK 56497-8-UG-EN • Manage Temperature Profiles • Upload Temperature Profiles • Import/Export Temperature Profiles 71 OptiSet™ Plus Functions • B o t t o m T o o l b a r : This is the row of button commands along the bottom of the OptiSet Plus interface. – Reset - Resets all of the OptiSet Plus values to the default unit settings. – Back - Switches to the previous OptiSet Plus menu screen. – Next - Switches to the next OptiSet Plus menu screen. Manage Temperature Profiles Allows the user to create new or modify existing temperature profiles. If a temperature profile is customized or a new one is created, information must be populated in all of the fields before it can be saved. Profile names should be under 24 characters long to verify proper interaction with the Human Machine Interface (HMI). N o t e : Field selections may affect the availability of other fields. Depending on the temperature profile selected, the following options may be available: • T e m p e r a t u r e P r o f i l e s : Select an existing temperature profile from the list of those available for the particular unit. • G e n e r a l T a b : Depending on unit configuration the following features may be available: N o t e : Selecting Create from the bottom toolbar will display a drop down list that has Named Profile and Numeric Profile as choices. Selecting any option will enable all available data fields. 72 TK 56497-8-UG-EN OptiSet™ Plus Functions • TK 56497-8-UG-EN – Named/Numeric: Select whether the new temperature profile has a name or number associated with it. Named temperature profiles are associated to specific commodities, numeric profiles are similar to temperature ranges in previous versions of OptiSet. If Numeric is selected, a complete set of ranges must be programmed. These ranges will cover the entire setpoint range. – Profile Name in OptiSet Plus: Enter the name that OptiSet Plus will display with the new temperature profile. – Profile Name In HMI: Enter the name that the HMI controller will associate with the new temperature profile. Profile names must be under 24 characters long. – Current Operating Mode: Determines the operating mode, either Continuous, Cycle Sentry, Selectable, or Temp Range Control. – Setpoint Low: Allows the lower setpoint limit to be set to a minimum of -30º F (-34º C) and a maximum of 90º F (32º C) in one degree increments. – Setpoint High: Allows the upper setpoint limit to be set to a maximum of 90º F (32º C) in one degree increments. The minimum setting is determined by the setting of Setpoint Low or Fresh Frozen Range. – Setpoint Default: Allows the default setpoint to be programmed. It can be set to any temperature from Setpoint Low to Setpoint High. This is the value that will be used for the setpoint when the commodity is selected, unless overridden by the operator. – Modulation Control: Use of the ETV and the Modulation Mode allow very precise temperature control. This mode provides constant airflow in the trailer by operating in Continuous Run. – Cycle Sentry Modulation: The user can either Disable or Enable this feature. C y c l e S e n t r y T a b : Depending on unit configuration the following features may be available: – MNTL Max Null Timer: Maximum Null Time Limit will cause the unit to start independently of box temperature demand, based on a timer that periodically starts the unit to move air inside the trailer. – MOTL Min Off Timer: Minimum Off Time Limit will not allow the unit to restart until a minimum amount of time has passed. Eliminates short cycle restarts and helps keep the engine off more. – High Speed Pulldown: If enabled, this feature offers the fastest temperature pulldown because the unit will run at highest capacity until the return air reaches setpoint. – Fuel Saver II: Allows more low speed operation after restart from Cycle Sentry null. – Null Restart Temperature: Amount of change in return air temperature before the unit is started after Cycle Sentry null. – Door Switch Option: Determines door switch operation. – Minimum Run Time: The user can set this feature from 0 - 60 minutes. 73 OptiSet™ Plus Functions • • 74 – Maximum Ambient: When ambient temperature is less than user defined maximum ambient, the unit will be allowed to go into NULL mode. – Minimum Ambient: When ambient temperature is more than user defined minimum ambient, the unit will be allowed to go into NULL mode. – Auto Ambient Cycle Sentry Mode: This is not a user configurable parameter. It will automatically be Enabled/Disabled based on the value selection of Maximum Ambient and Minimum Ambient. If the maximum ambient value is set at or above 140°F (60°C) and the minimum ambient value is set at or below -50°F (-46°C), or the maximum ambient and minimum ambient are the same, this feature is not Enabled. C o n t i n u o u s T a b : Depending on unit configuration the following features may be available: – High Speed Pulldown: If enabled, this feature offers the fastest temperature pulldown because the unit will run at highest capacity until the return air reaches setpoint. – Fuel Saver II: If enabled, this will allow more low speed operation after the unit has reached setpoint the first time unless high speed capacity is needed to get back to setpoint. If disabled, unit may run in low speed with the return air above setpoint for extended periods of time if low speed capacity is not great enough to get the return air back to setpoint. – LSC To LSC FSII Switch Point: Set this feature higher to obtain higher fuel economy. However, temperature control will not be as precise. Setting this feature lower will provide tighter temperature control, but the unit will use more fuel. – Door Switch Option: Determines door switch operation. – Minimum Discharge Air Mode: If enabled, this feature limits the minimal discharge air temperature to prevent top freeze. This can impact the units ability to reach setpoint. C y c l e S e n t r y M o d u l a t i o n T a b : Depending on unit configuration the following features may be available: TK 56497-8-UG-EN OptiSet™ Plus Functions – MNTL Max Null Timer: Maximum Null Time Limit will cause the unit to start independently of box temperature demand, based on a timer that periodically starts the unit to move air inside the trailer. – MOTL Min Off Timer: Minimum Off Time Limit will not allow the unit to restart until a minimum amount of time has passed. Eliminates short cycle restarts and helps keep the engine off more. – Null Restart Temperature: Amount of change in return air temperature before the unit is started after Cycle Sentry null. – Floor Limit: Floor limit is a product protection feature. It limits how cold the discharge air can be that blows from the unit onto the load, or into the air chute. Example: If you have a Floor Limit setting of 10°F with a setpoint of 35°F, Discharge Air will go no lower than 25° F. Setting Floor Limit can have significant impact upon the unit’s ability to maintain setpoint in extreme ambient/high heat load situations, fuel consumption, and load quality. For these reasons, Floor Limit settings should take into account the products hauled, the coldest temperature the product will tolerate without damage, how the product is packaged and the load is configured, and whether or not chutes are used in the trailer, and if so, whether they are in good working order. Generally speaking, the higher the floor limit, the easier it will be for the unit to maintain setpoint in high heat load situations at low speed, potentially saving fuel. Higher floor limits may be desirable with air chutes provided they are in good repair. This is because the discharge air will be warmed slightly as it picks up heat from the ceiling, especially on hot, sunny days. Lower floor limits require more high speed operation to maintain setpoint (higher fuel consumption), but provide better chill damage protection for sensitive cargoes. • TK 56497-8-UG-EN – Door Switch Option: Determines door switch operation. – Minimum Run Time: The user can set this feature from 0 - 60 minutes. – Maximum Ambient: When ambient temperature is less than user defined maximum ambient, the unit will be allowed to go into NULL mode. – Minimum Ambient: When ambient temperature is more than user defined minimum ambient, the unit will be allowed to go into NULL mode. – Auto Ambient Cycle Sentry Mode: This is not a user configurable parameter. It will automatically be Enabled/Disabled based on the value selection of Maximum Ambient and Minimum Ambient. If the maximum ambient value is set at or above 140°F (60°C) and the minimum ambient value is set at or below -50°F (-46°C), or the maximum ambient and minimum ambient are the same, this feature is not Enabled. C o n t i n u o u s M o d u l a t i o n T a b : Depending on unit configuration the following features may be available: 75 OptiSet™ Plus Functions – Controlling Sensor: Determines the controlling sensor, either the Return Air Temperature Sensor or Discharge Air Temperature Sensor. – PMAX: Modulation Pulldown Option. Not available if unit is not configured as an ETV or Modulation is programmed Off. PMAX = ON - The minimum discharge air is not regulated. A time and temperature integral limits the amount of time that the discharge air temperature is below the floor limit. PMAX = OFF - High Speed Modulation is entered when the discharge air reaches the floor (return air control) or the setpoint (discharge air control), but the unit remains in high speed (diesel), or cool (electric). Limited pulldown capacity is maintained while controlling the minimum discharge air temperature. – Floor Limit: Floor limit is a product protection feature. It limits how cold the discharge air can be that blows from the unit onto the load, or into the air chute. Example: If you have a Floor Limit setting of 10°F with a setpoint of 35°F, Discharge Air will go no lower than 25° F. Setting Floor Limit can have significant impact upon the unit’s ability to maintain setpoint in extreme ambient/high heat load situations, fuel consumption, and load quality. For these reasons, Floor Limit settings should take into account the products hauled, the coldest temperature the product will tolerate without damage, how the product is packaged and the load is configured, and whether or not chutes are used in the trailer, and if so, whether they are in good working order. Generally speaking, the higher the floor limit, the easier it will be for the unit to maintain setpoint in high heat load situations at low speed, potentially saving fuel. Higher floor limits may be desirable with air chutes provided they are in good repair. This is because the discharge air will be warmed slightly as it picks up heat from the ceiling, especially on hot, sunny days. Lower floor limits require more high speed operation to maintain setpoint (higher fuel consumption), but provide better chill damage protection for sensitive cargoes. • 76 – High Speed Modulation: Set to ON to provide higher airflow and higher refrigeration capacity while in modulation, but will use more fuel. Set to OFF to save fuel. Cool climates and low heat load conditions may work well with this setting. – High Speed Modulation Ceiling: Determines the switch point for low speed to high speed modulation and for the termination of high speed modulation. – Low Ambient Temperature Override: Low ambient temperatures could result in “coldspots” forming in the refrigerated environment; these cold-spots could be detrimental to the commodity being transported. To reduce the risk from these cold-spots, the temperature override feature switches the unit to run in high speed periodically, increasing air-flow and eliminating the “cold-spot”. Available only if High Speed Modulation is On. – High Ambient Temperature Override: High ambient temperatures could result in “hotspots” forming in the refrigerated environment; these hot-spots could be detrimental to the commodity being transported. To reduce the risk from these hot-spots, the temperature override feature switches the unit to run in high speed periodically, increasing air-flow and eliminating the “hot-spot”. Available only if High Speed Modulation is On. – Freeze Protection: The freeze protection mode controls the discharge air temperature to 35°F minus the programmed floor limit. It is a subset of return air modulation control. It is designed for higher temperature setpoints that have a high refrigeration load or are transported in a lightly insulated trailer. Available only if return air modulation control is enabled. – Door Switch Option: Determines door switch operation. B o t t o m T o o l b a r : This is the row of button commands along the bottom of the OptiSet Plus Manage Temperature Profiles interface. TK 56497-8-UG-EN OptiSet™ Plus Functions – Back: Switches to the previous Temperature Profile in the group – Group Name: Displays the group name which is used by OptiSet Plus to index the Temperature Profiles. If there is more than one range in a numeric Temperature Profile, the number of ranges will be indicated with a (#) following the Group Name. – Next: Switches to the next Temperature Profile in the group. – Create: Create a new Temperature Profile. Select from either Named Profile or Numeric Profile. – Customize: Customize an existing Temperature Profile. – Delete: Delete the Temperature Profile from the library. – Save: Saves the new or modified Temperature Profile. If a temperature profile is customized or a new one is created, information must be populated in all of the fields before it can be saved. Profile names should be under 24 characters long to verify proper interaction with the HMI. – Cancel: Cancel changes to the Temperature Profile. Upload Temperature Profiles Selecting this tab allows the user upload existing temperature profiles to the application. The following options are available: TK 56497-8-UG-EN • T e m p e r a t u r e P r o f i l e s L i b r a r y : Browse for a temperature profile in the Thermo King or User Library. Holding the shift key allows the selection of multiple temperature profiles within a span. Holding the ctrl key allows individual selection of multiple temperature profiles. • A d d : Add the selected temperature profile to the Selected Profiles list for upload to the application. • R e m o v e : Remove the selected temperature profile from the Selected Profiles list for upload to the application. • R e m o v e A l l : Remove all of the temperature profiles from the Selected Profiles list for upload to the application. • S e l e c t e d P r o f i l e s : List of the selected temperature profiles for upload to the application. A maximum of 64 temperature profiles can be uploaded. Multiple ranges indicated with a (#) will count individual ranges against the maximum number of temperature profiles allowed. 77 OptiSet™ Plus Functions • B o t t o m T o o l b a r : This is the row of button commands along the bottom of the OptiSet Plus interface. – Reset - Resets all of the OptiSet Plus values to the default unit settings. – Back - Switches to the previous OptiSet Plus menu screen. – Next - Switches to the next OptiSet Plus menu screen. Import/Export Temperature Profiles Selecting this tab allows the user to import or export existing temperature profiles. There are two tabs under Import/Export Temperature Profiles, Import and Export. • • 78 I m p o r t T a b : Selecting this accesses the Import Temperature Files Menu with the following commands: – Select File To Import Temperature Profiles - Browse for an existing temperature profile outside of the application libraries to import. – Profiles From Import File - Select an existing temperature profile to import from within the application. – Add - Add the selected temperature profile to the Selected Profiles list for import. – Add All - Add all of the temperature profiles in the list to the Selected Profiles list for import. – Remove - Remove the selected temperature profile from the Selected Profiles list for import. – Remove All - Remove all of the temperature profiles from the Selected Profiles list for import. – Import - Select the Import button when the desired temperature profiles are in the Selected Profiles list for import. The selected temperature profiles will be imported into the User Library. – Selected Profiles - List of the selected temperature profiles for import. E x p o r t T a b : Selecting this accesses the Export Temperature Files Menu with the following commands: TK 56497-8-UG-EN OptiSet™ Plus Functions • – Profiles From Custom Profile Library - Select an existing temperature profile to export from the application. – Add - Add the selected temperature profile to the Selected Profiles list for export. – Remove - Remove the selected temperature profile from the Selected Profiles list for export. – Remove All - Remove all of the temperature profiles from the Selected Profiles list for export. – Export - Select the Export button when the desired temperature profiles are in the Selected Profiles list for export. The temperature profiles are placed in a file which can then be imported into another installation of OptiSet Plus. – Selected Profiles - List of the selected temperature profiles for export. B o t t o m T o o l b a r : This is the row of button commands along the bottom of the OptiSet Plus interface. – Reset - Resets all of the OptiSet Plus values to the default unit settings. – Back - Switches to the previous OptiSet Plus menu screen. – Next - Switches to the next OptiSet Plus menu screen. Generate Interchange File Menu OptiSet Plus can generate a report file or an OSP interchange file that gives detailed information about the current OptiSet Plus configuration. Check any combination of the following components to include in the Report or Interchange File. TK 56497-8-UG-EN 79 OptiSet™ Plus Functions • U n i t S e t u p : Select to include Unit Setup information in the Report or Interchange File. • C a r g o W a t c h S e t u p : Select to include CargoWatch Setup information in the Report or Interchange File. • T e m p e r a t u r e P r o f i l e s : Select to include Temperature Profiles information in the Report or Interchange File. • G e n e r a t e R e p o r t : Select to generate a Report with the selected components. All Report files should be saved to the "UserDataStore/Reports" folder to maintain consistency and preservation of file locations. If "Print" is used, the file should be saved to the same location. The following options are available: • 80 – Print - Print the active report file. Click "Print" to save the file in different formats. Selecting "Adobe PDF" will generate a .pdf file. This feature is enabled only if acrobat reader is installed on the computer. – Save - Save the active report file. The active report can be generated for Unit Setup and CargoWatch Setup separately. Select "Save" to generate the report. This report is in .html format. All Report files should be saved to the "UserDataStore/Reports" folder to maintain consistency and preservation of file locations. G e n e r a t e I n t e r c h a n g e F i l e : Select to generate an OSP Interchange File with the selected components. All interchange files should be saved to the "UserDataStore/OPTISETPLUS" folder to maintain consistency and preservation of file locations. OptiSet Plus interchange files can be uploaded into Thermo King transport refrigeration units using the Wintrac Service Tool. TK 56497-8-UG-EN Glossary TK 56497-8-UG-EN Ambient Air The air surrounding an object. Ambient Temperature Temperature of the air surrounding an object. Base Controller The brains and the muscle of the truck/trailer control system. Box A temperature controlled compartment. Capacity The ability of a refrigeration system to remove heat. Cargo The goods or materials being transported. CargoWatch™ The CargoWatch data logger is part of the HMI Control Panel. The data logger is downloaded using the CargoWatch port located just above the HMI Control Panel. Celsius The metric unit of temperature measurement (°C). Continuous Mode In Continuous Mode the unit is started and continues to run, even if all temperature control requirements are satisfied. This provides constant airflow over and around the cargo. Cycle Sentry Mode Cycle Sentry Mode automatically starts the unit when cooling, heating or defrosting is required and stops the unit when all requirements are satisfied. In Diesel Mode operation the unit also starts and stops as necessary to keep the engine warm and the unit battery charged. In Electric Mode operation the unit starts and stops as necessary to keep the unit battery charged. DAS Data Acquisition System. An electronic device that monitors and stores unit operating and temperature data for later review. Economy Mode If Economy Mode is turned on, a relaxed set of default values are used for both Cycle Sentry and Continuous Mode operation. The result is increased fuel economy. ETV Electronic Throttling Valve. A device used with the microprocessor to precisely control the refrigeration system. Fahrenheit A unit of temperature measurement (°F). HMI Human Machine Interface. The full functioned graphics HMI consists of an LCD graphics display screen and eight touch sensitive keys. The four keys on the sides of the control panel are used to turn the unit on and off, initiate a manual defrost cycle, and select the desired operating mode. The function of the four keys located below the display screen change as required by the current menu. These are known as software controlled keys or ‘soft keys’. The current function of the key is controlled by software and displayed directly above the key. This definition will change depending on the application. The HMI is a message center. Interchange File The interchange file is the output from the OptiSet Plus PC application. This is read by the Wintrac PC application. Wintrac then uploads the temperature profiles recorded in the interchange file to the Transport Refrigeration Unit. Null An inactive state (not heating or cooling) when box temperature equals the temperature setpoint. Modulation An optional system that reduces cargo dehydration and avoids “top freeze”. Setpoint The temperature selected on a thermostat or microprocessor controller. This is normally the desired box temperature. Temperature Describes the intensity of heat. The two common scales for this measurement are Fahrenheit (°F) and Celsius (°C). Temperature Profile A set of attributes that are specific to maintaining temperature on the controller. May either be user created or part of a Thermo King optimized library. 81 Glossary 82 TracKing™ Existing Thermo King PC application that can be used to remotely monitor cargo conditions and microprocessor settings of a load in transit. WinTrac™ Existing Thermo King PC application that can be used to download existing temperature profiles from a Transport Refrigeration Unit for examination in OptiSet Plus. TK 56497-8-UG-EN Notes TK 56497-8-UG-EN 83 Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club Car®, Ingersoll Rand®, Thermo King® and Trane® — work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. TK 56497-8-UG-EN 01 Sep 2018 Supersedes TK 56497-8-UG-EN (October 2017) ©2017 Ingersoll Rand
0
Puede agregar este documento a su colección de estudio (s)
Iniciar sesión Disponible sólo para usuarios autorizadosPuede agregar este documento a su lista guardada
Iniciar sesión Disponible sólo para usuarios autorizados(Para quejas, use otra forma )