D
C
B
C
re
FU
0.4
Roping
2:1
100
D/sheave
100
CW sheave
100
1200
mm x HD
2000
mm
Cabin
CW
800
mm x CD
1300
mm
Door
OP
600
mm x OPH
2000
Speed
0.4
OH
Pit
mm
(m/s)
2.0
(KW)
≥3300
(mm)
≥300
(mm)
380V 3phase 5wire,50Hz,fluctuation ±7%
Support Force (N)
R1
R2
R3
R4
P1
P2
P3
P4
45000 34000
P
ci
si
on
Hoistway Liight Per≤7000
CAR&CWT.RAIL BRACKET SPACING≤2000
FU
JI
The work that the owner and the
construction party should complete
1.The constrution and waterproofing
of pit about the shaft and machine
room;
2.The dynamic power from the
receving box,piping of lighting
earth line project and including
the main switch;
3.Reserved hole about each exists
and machine room floor;
4.The filling and whitewash project
after finishing theinstallation
about elevators door frane;
5.Machine room
door,ventilation,lighting and the
cinder and concreate on the floor
after finishing the construction;
6.Piping and wring about the
emergency call from machine room to
management room;
OH
≥3300
Rise
H
Others:
In accrodance with the provising og
the building ordinance,it is not
allowed to arrange water
pipe,electricity pipe, wind pipe in
the shaft that are inprespective
with the elevator.
5F
4F
3F
300
1F
-1F
Drawing
-2F
Drawing No.
-3F
Pit
Approver
FT-J 400 -11-
Manufacturing no.
≥300
Project name
FUJI PRECISION
B
∅
∅
m/s
HW
2F
50
Pit Depth
≥300
FU
Pit plan
Side open
Speed
Shaft
Power
300
JI
Pr
e
Rise=H
HD=2000
E
Finished floor
HW=1200
∅
∅
T/sheave
car sheave
700
CH=2200(Ceiling net height2050)
OH ≥3300
Pr
e
JI
FU
840
io
is
If there is interference,
you need to knock on the wall
By others
ec
200
Door type
Machine
28800 17200
Finished floor
P1
150
30
2-200×200
OVERHEAD HEIGHT
The hook(15kn,indicate on the hook)
Note:Can't break into the elevator shaft
876
400
n
HD=2000
CD=1300
587
840
876
726
DOOR OPENING HEIGHT
284
284
78
Hoistway plan
D
OPH
OH
/
4
4
CW=800
HW=1200
WALL OPENING WIDTH
600
600
CAR DBG=920
200
ROP
TJJ 400 / 0.4
3
600
P2
OP=600
400 kg
base station remaining stations
lighting
78
load
100 Wx400 H
Bottom box Lop 100 Wx500 H
∅50 hole
No bottom box
3
ci
si
on
E direction Doorway schematic
Facing Hoistway
WT DBG=680
re
500
HW=1400
CAR HEIGHT
DOOR OPENING WIDTH
ci
si
on
wall
ROP=800
Overhead plan
600
Shaft
wall
100
/
CWT DBG DISTANCE BETWEEN COUNTERWEIGHT GUIDE RAILS
Finished floor
OP=600
HW=1200
F/P/D
CAR DBG DISTANCE BETWEEN CAR GUIDE RAILS
Lop hole
(See table)
150
Shaft
Thickness≤50
R2
type
CAR INSIDE DEPTH
800
ec
is
400
700
OPH=2000
OH ≥3300
JI
HD=2000
FU
876
350
246
R2
CAR INSIDE WIDTH
CD
CH
2
2
210 200
840
R1
Net height=2100
429
500
R1
CW
HOISTWAY DEPTH
Left and right load beam
Door beam
Pr
50
≥350
The hook
HOISTWAY WIDTH
HD
OP
1
600
Controller
1
600
500
HW
200
Schematic diagram of hook
400
Other
io
n
Brick & Concrete
1300
Concrete
Technical Requirement
JI
P
Control cabinet size
Hoistway Structure
200
Steel belt traction
MRL Home elevator
A
NOTE
A