Subido por Daniel Figueroa

MV GEORGIOS S-

Anuncio
UNITED SURVEYS CHILE
Marine & Cargo Surveyors – Quality Control Service
www.unitedsurveychile.com
[email protected] |Phone +56-55-2560490 |Direct 24/7 +56 9 93233396 - +56 9 54135955
INSPECTION REPORT
United Ref. Nr: US-ANF-1810325
Cave Ref: 2018/0261/JMB
In compliance with the instructions received of Messrs. CAVE & Co Ltd. on behalf of P&I Club, we
certify that we UNITED SURVEYS CHILE have carried out a loading supervision of Copper
concentrate according to IMSBC CODE on board the vessel.
-
At Las Ventanas Port – Chile and the undersigned surveyor attended from October 22th to
October 25th, 2018:
1. - General view of MV GEORGIOS S – Berthed at Las Ventanas
Port.
1
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
VESSEL DETAILS
Vessel Name
Flag
GRT
DWT
Agent
Type of ship
Year of Build
IMO
GEORGIOS S
VALLETA
29,417
55,725
ULTRAMAR
BULK CARRIER
2006
9303053
2. - View of MV GEORGIOS S.
1. DATES & TIMES OF OPERATIONS DETAILS
1.1 DATES & TIMES OF OPERATIONS DETAILS
19-10-2018
20-10-2018
21-10-2018
22-10-2018
22-10-2018
23-10-2018
24-10-2018
25-10-2018
20:00
20:25 – 23:59
00:00 – 15:20
15:20 – 23:59
00:00 – 00:20
00:20 - 23:59
00:00 – 20:58
20:48
22:30
23:20 – 23:45
23:56 – 00:25
00:30 – 00:40
00:35
01:10
02:30
12:50
11:00
20:00
05:00
06:20
07:10 – 09:35
09:45
14:00
22:00
05:00
06:55
13:35
17:00
Vessel arrival to Quintero bay pilot station.
Vessel waiting at anchorage due to pier N°2 is busy
Vessel waiting at anchorage due to pier N°2 is busy
Vessel waiting at road due to heavy swell
Vessel waiting at road due to heavy swell
Vessel waiting at anchorage due to pier N°2 is busy
Vessel waiting at anchorage due to pier N°2 is busy
POB for berthing manoeuvres
Vessel berthed
USC surveyor attended on board vessel, meeting with Captain.
Hold inspection by USC Surveyor LH4.
Hold inspection by USC Surveyor LH1.
Commenced operation in LH4
Stopped operation due to problems in conveyor belt
Can test performed by USC.
Resume operation
Can test performed by USC.
Can test performed by USC.
Can test performed by USC.
Completed loading operation in LH4
Shifting from LH4 to LH1
Commenced loading operation in LH1
Can test performed by USC.
Can test performed by USC.
Can test performed by USC.
Completed cargo operation in LH1
Completed trimming accepted by the vessel
Departure
2
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
2. WEATHER CONDITIONS
2.1 WEATHER CONDITIONS
The atmospheric conditions during the survey were good; the inspection was carried out without
any restriction. No rain or strong wind or heavy swell was observed during this survey.
3.
INSPECTION REPORT
According instruction received from P&I the scope to be inspected was as follow:

To carried out a survey loading supervision of Copper concentrate according to IMSBC CODE
on board the vessel GEORGIOS S.
3.1.
PRE-LOADING INSPECTION

On board the vessel, our Surveyor met with the Vessel´s Master prior to loading operations.
Vessel´s Master receipt all information of cargo, pre-shipment certificate (in order), shipper’s
declaration with abstract of recommendations of IMSBC code, regarding to operations with this
type of cargo. Additionally our surveyor provides recommendations to Vessel´s Master.

Access to stockpile was denied to external Surveyors by internal Codelco Terminal´s safety
procedures.

Pre-shipment Certificate Nr. PVE-10-1636/2018 PVE-10-1637/2018 was issued by SGS
Laboratories on behalf of Messrs. Anglo American Sur, Chile..
CARGO CERTIFICATES – PVE-10-1636/2018 Copper Concentrate LH1
Pre-shipment certificate was issued by SGS
Parameters of moisture according to Pre-shipment certificate, as follows:
Angle of repose
43 to 45 degree
Load factor
0,55 m3 / wmt
Flow Moisture Point
11 %
Transportable Moisture limit
9,90 %
Moisture content
8,27 %
Sampling Tonnage
10,450.00 tons
Note: Due to Transportable moisture (9,9 %) was a higher value than moisture contents (8,27 %),
It means that copper concentrate was according to “International Maritime Solid Bulk Cargo Code
(IMSBC).
3
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
CARGO CERTIFICATES – PVE-10-1637/2018 Copper Concentrate LH4
Pre-shipment certificate was issued by SGS
Parameters of moisture according to Pre-shipment certificate, as follows:
Angle of repose
44 to 46 degree
Load factor
0,55 m3 / wmt
Flow Moisture Point
10,56 %
Transportable Moisture limit
9,5 %
Moisture content
7,40 %
Sampling Tonnage
11,600.00 tons
Note: Due to Transportable moisture (9,5 %) was a higher value than moisture contents (7,40 %),
It means that copper concentrate was according to “International Maritime Solid Bulk Cargo Code
(IMSBC).
3.2.
PRE-LOADING INSPECTION


On board the vessel, our Surveyor met with the Vessel´s Master prior to loading
operations. Vessel´s Master receipt all information of cargo, pre-shipment certificate (in
order), shipper’s declaration with abstract of recommendations of IMSBC code, regarding
to operations with this type of cargo. Additionally our surveyor provides
recommendations to Vessel´s Master.
Access to stockpile was denied to external Surveyors by internal Codelco Terminal´s safety
procedures.
3.2.1. DETAILS OF CARGO ACCORDING TO CARGO MANIFEST
Mate’s Receipt 1
Shipper
Consignee
Description
POL/POD
Weight
ANGLO AMERICAN SUR S.A.
To order
Los Bronces Copper concentrates
Ventanas Port, Chile / Huludao, China .
10,449.480 WMT
Mate’s Receipt 2
Shipper
Consignee
Description
POL/POD
Weight
ANGLO AMERICAN SUR S.A.
To order
Los Bronces Copper concentrates
Ventanas Port, Chile / Huludao, China .
11,611.250 WMT
4
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
4. INSPECTION OF CARGO HOLDS
Inspection of holds Nr. 1 & 4 was performed jointly with shipper representative and Chief Officer.
Hold was found dry and clean. Hold was approved by shipper’s surveyor.
Our inspector found the hold in good condition, clean & dry. Tank top plating and bulkheads were
found and without signs of water. Bilge covers were found with the seal.
Hatch Covers
Drain Holes
Non Return Valves
Acting Cleats
Compression Bars
Deck Beams & Brackets
Hull Frames & Brackets
Bulkhead
Ladders
Pipping & Casing
Tank Top Taking
Bilges
HOLD Nr.1
Rubber gaskets in general good condition.
No damage noted, clean.
No damage noted.
General good condition.
General good condition.
No damage noted.
No damage noted.
No damage noted, clean and dry.
General good condition.
No damage noted.
Clean and dry, rusty.
Sealed with burlap.
3. - View of access stevedores, LH1.
4. - View of rubber gasket condition, LH1.
5
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
5. - View of compression bars condition, LH1.
6. - View of compression bars condition, LH1.
7. - View of non return valve condition, LH1.
8. - View of acting cleats condition, LH1.
9. - View of hold condition, LH1.
10. - View of hold condition, LH1.
6
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
11. - View of bilge, LH1.
Hatch Covers
Drain Holes
Non Return Valves
Acting Cleats
Compression Bars
Deck Beams & Brackets
Hull Frames & Brackets
Bulkhead
Ladders
Pipping & Casing
Tank Top Taking
Bilges
12. - View of bilge sealed with burlap.
HOLD Nr.4
Rubber gaskets in general good condition.
No damage noted, clean.
No damage noted.
General good condition.
General good condition.
No damage noted.
No damage noted.
No damage noted, clean and dry.
General good condition.
No damage noted.
Clean and dry, rusty.
Covered sealed.
13. - View of access stevedores, LH4.
14. - View of compression bars condition, LH4.
7
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
15. - View of compression bars condition, LH4.
16. - View of rubber gasket condition, LH4.
17. - View of non-return valve condition, LH4.
18. - View of acting cleats condition, LH4.
19. - View of cargo hold condition, LH4.
20. - View of cargo hold condition, LH4.
8
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
21. - View of bilge, LH4.
22. - View of bilge covered sealed, LH4.
5. CARGO DISTRIBUTION
5.1. CARGO DISTRIBUTION
HOLD 5
HOLD 4
----
11,600.00 wmt
Huladao, China
Copper
Concentrates
STOWAGE PLAN
HOLD 3
----
HOLD 2
HOLD 1
----
10,450.00 wmt
Huludao, China
Copper
Concentrates
Total Cargo loaded on board Holds Nr. 1 & 4: 23,736.00 wmt (as per Shore Figure)
Op. Nr.
1
2
3
4
Sequence
Loading LH4
Loading LH1
Loading LH1
Loading LH1
LOADING SEQUENCE
Cargo WMT
Comments
11,600.00
Huludao Cargo
6,000.00
Huludao Cargo
3,000.00
Huludao Cargo
1,450.00
Huludao Cargo
6. LOADING OPERATIONS
6.1
LOADING OPERATIONS
Loading operations was performed using a conveyor belt feeder located inside the covered
warehouse. The cargo was transported by the belt conveyor at an average rate of 800 to 1000
wmt per hour approximately. Conditions of the material during this transportation remained good.
9
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
23. - View of loading system (conveyor belt).
24. - View of loading operation in Hold Nr.1.
25. - View of loading operation in Hold Nr.1.
26. - View of loading operation in Hold Nr.4.
7. CONDITION OF CARGO
7.1 CONDITION OF CARGO
In Cargo Holds Nr.1 & 4, the cargo showed no apparent dirt and/or foreigner materials. The cargo
is in clean condition.
The condition of cargo was inspected during all loading operation and did not present any sign of
apparent contamination. Furthermore, the cargo presented a dry fine granular appearance,
without water puddles standing on it.
10
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
27. - View of cargo condition in Hold Nr.1 .
28. - View of final cargo condition in Hold Nr.1.
29. - View of cargo condition in Hold Nr.4.
30. - View of final cargo condition in Hold Nr.4.
8. CAN TEST
8.1
CAN TEST
In order to ascertain mechanically the Transportable Moisture Limit (TML) of copper concentrates
loaded onboard MV. GEORGIOS S it was performed can test. Disposed sample of copper
concentrates (0.5 to 2 kg) in a cylinder recipient to be lifted and drop on to a hard surface about 25
times from 20 cm (height) with intervals of 1 or 2 seconds. Afterwards, we could observe the
surface of product without abnormalities and Transportable Moisture Limit (TML) according to
“International Maritime Solid Bulk Cargo Code (IMSBC) recommendations”.
Cant test was carried out in cargo holds Nr. 1 & 4, finding the cargo without alterations regarding to
the moisture presence.
11
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
31. - View of United Surveyor conducting can 32. - View of obtained sample, LH1.
test in hold Nr.1.
33. - View of United Surveyor conducting can 34. - Once can test was performed, the cargo
test in hold Nr.1.
not showed alterations regarding to the
moisture presence, LH1.
35. - View of United Surveyor conducting can 36. - Once can test was performed, the cargo
test in hold Nr.1.
not showed alterations regarding to the
moisture presence, LH1.
12
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
37. - Once can test was performed, the cargo 38. - Once can test was performed, the cargo
not showed alterations regarding to the not showed alterations regarding to the
moisture presence, LH1.
moisture presence, LH1.
39. - View of United Surveyor conducting can 40. - Once can test was performed, the cargo
test in hold Nr.4.
not showed alterations regarding to the
moisture presence, LH4.
41. - Once can test was performed, the cargo 42. - Once can test was performed, the cargo
not showed alterations regarding to the not showed alterations regarding to the
moisture presence, LH4.
moisture presence, LH4.
13
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
9. CONCLUSIONS

Cargo Holds Nr. 1 & 4 were found clean, dry and suitable for receiving the copper
concentrates in bulk.

In Cargo Holds Nr 1 & 4, the cargo showed no apparent dirt and/or foreigner material had
been observed. The cargo is in apparently and superficially cleans condition.

Parameters of Pre-shipment certificate stated that cargo was suitable for transportation.

Can test was performed in cargo holds Nr. 1 & 4, finding the cargo without alterations
regarding to the moisture presence.

Vessel’s Master was informed during all time about loading procedure and IMSBC Code
recommendations. Copper concentrates were loaded under our continual supervision.

The final moisture ascertained, as per moisture method for the Copper cargo loaded
10,449.480 wmt was 8,72% for LH1. And 11,611.250 wmt was 7,79% for LH4. (Moisture
certificate is attached to this report. Ventanas Port, Holds Nr 1 & 4)
10. ATTENDING PARTIES
Name
Mr. Santi Borchan
Mr. Daniel Figueroa
Position
Master
United Surveys Chile
On behalf of
Owner
P&I Club
11. ATTACHMENTS

Pre Shipment Certificate issued by Laboratories on behalf of Shipper.

Shipper Declaration issued by Laboratories on behalf of Shipper.

Statements of facts

Mate´s receipt.

Moisture certificate

Cargo manifest

Notice of Readiness

Stowage plan

No damage certificate
14
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
United Ref. No: US-ANF-1810325
This report is issued without any prejudice and in the interest of whom it may concern.
UNITED SURVEYS CHILE
René Albornoz Palma
Operations Service Manager
Antofagasta, Chile. October 27th, 2018
JMV//rap
15
In accepting this survey it is agreed that extent of the obligation of this company with respect there to is limited to furnishing a surveyor believed to the competent and in the making of this
inspection the surveyor is acting impartially and to the best of his ability and no liability shall attach to the company or the surveyor for the accuracy there off. Our responsibility can never exceed
the amount of our fees.
Descargar