EN54 IP Networked System PUBLIC ADDRESS AND VOICE ALARM FEATURES • Alarm, prerecorded and live messages. • Music broadcasting. • Management of speaker zones. • Microphone desks connected by bus or through the corporate data network. • Reception of 4 simultaneous digital audio channels via IP connection. • Output/input contacts for emergency functions, message activation, zone control ... • Audio outputs with individual volume control. • Critical path supervision: speaker lines, amplifiers, cards, power, contacts, prerecorded messages ... • Call point software for live or prerecorded messages, alarm notification ... • PC integration (XML) and direct integrations (JSON, SNMP, API/DLL). • Control data reception and transmission via IP connection. • Compatible with SIP protocol. • Linked systems through corporate network and accessible from IP points (microphones, SIP phones ...). • Double Ethernet connection (Layer 2 & 3) and double power supply input for redundant installations. • Operation over the Internet via VPN FEATURES Suitable for both centralized or distributed systems, scalable and modular, for infrastructures of any type and size, linked through the corporate data network. DIAGRAM Audio inputs Volume control Fire Alarm System integration Analog Control microphones Noise sensors IP microphones Speaker areas SIP compatibility IP audio channels High capacity Network connection Global control AoIP layer 2 or layer 3 EQUIPMENT COMPACT Audio matrix (main unit) with IP connection With Input/Output contacts card UMX-C16 and audio input card UMX-EA3. With 8 free slots to insert cards UMX-C16 | UMX-EA3 | UMX-2M3 UMX-2SA | UMX-MC6 | UMX-2SB* Up to 20 COMPACT networked COMPACT-E Expansion unit With 10 free slots to insert cards UMX-2SA | UMX-MC6 | UMX-2SB* Up to 10 COMPACT-E (each COMPACT) EQUIPMENT COMPACT Includes power supply and control module 1 – ETH A connector 2 – ETH B connector (redundant network) 3 – CAN bus for microphones and noise sensors 4 – FAIL contacts (system alarms) 5 – GND 6 – Input contacts (3), supervised 7 – Output contacts (3) 8 – Main power supply 9 – Secondary power supply (redundant) 10 – Audio bus expansion (to COMPACT-E) 11 – Main power supply fuse 12 – Secondary power supply fuse 13 – Grounding EQUIPMENT UMX-C16 I/O contacts card 16 input contacts with possibility of supervision. 4 output contacts (dry contact or referred to ground). EQUIPMENT UMX-EA3 Card with two audio inputs Audio level adjustment. Possibility to pre-set the zones for each input Priority by PTT or VOX Signal of activated zones (ACK) Configurable sensitivity 0 dB | -20 dB | -60 dB | -60 dB + speechfilter EQUIPMENT UMX-2M3 Card with two music audio inputs Stereo RCA connectors; internal sum of the L and R • Audio level adjustment • Configurable sensitivity via software AUX H (775 mV) and AUX L (100 mV) EQUIPMENT UMX-2SA Card with two audio outputs 2 x 0dB / 600 Ohm and priority (RJ45) Up to +4dB for ProSound power units Fault detection and indication in amplifier or speaker lines Transformer balanced outputs Volume control from front panel or remote device Fault detection and indication in amplifier or speaker lines Bass / treble equalization or 10 bands EQUIPMENT UMX-MC6 Card with 6 speakers subzone outputs Security paging Compatible with 3 or 4 wire attenuators Double 100 V input channel I (music) Channel II (paging and/or backup). A/B zones configuration EQUIPMENT UMX-2SB* Card with speakers subzone outputs (4, 8, 12 or 16) 2 balanced audio outputs directed to 4, 8, 12 or 16 sub-zones (depending on the model) Individual volume adjustment in music program subzones Volume control from front panel or remote device Double 100 V input: channel I (music) and channel II (warnings and / or backup) Speaker lines and power units measurement Sub-zones outputs with security paging *UMX-2SB1: 4 subzones UMX-2SB2: 8 subzones UMX-2SB3: 12 subzones UMX-2SB4: 16 subzones A/B zones configuration Bass / treble equalization or 10 bands SPEAKERS ZONES 1 x COMPACT 10 x COMPACT-E A | Individual alarm and music volume control B | Individual music volume control and general alarm volume control 108 x UMX-2SA 22 x UMB-2SB C | General alarm and music volume control 1 x UMX-2SA 107 x UMX-MC6 216 zones 352 zones 642 zones EXAMPLES UMX-2SA Card with two audio outputs UMX-2SA Up to 8 cards in COMPACT Up to 10 cards in COMPACT-E Individual voice volume control Individual music volume control Voice & music Voice & music EXAMPLES UMX-2SA + UMX-MC6 Card with two audio outputs Card with subzone outputs UMX-MC6 Multiple combinations n x UMX-2SA m x UMX-MC6 n+m ≤ 108 UMX-2SA General voice volume control General music volume control 1 2 6 Voice Music & backup EXAMPLES 1 UMX-2SA + UMX-MC6 UMX-MC6 Card with two audio outputs Card with subzone outputs 1 x backup for several zone amplifiers Voice & music 6 UMX-2SA Voice & music 1 UMX-MC6 UMX-2SA Backup 2 2 6 EXAMPLES UMX-2SB4 Card with subzone outputs 1 General voice volume control Individual music volume control UMX-2SB4 Up to 2 cards in COMPACT Up to 2 cards in COMPACT-E 2 16 Voz Música y backup EXAMPLES UMX-2SB Card with subzone outputs 1A Up to 2 cards in COMPACT Up to 2 cards in COMPACT-E A + B mode 1B UMX-2SB General voice volume control Individual music volume control 8A 8B Voz Música y backup EXAMPLES COMPACT + 2 x UMX-2SB COMPACT-E + UMX-2SB + UMX-2SA + (UMX-2SA + 4 x UMX-6MC) 74 zones MICROPHONES ME-200B Fireman's panel with microphone Emergency message board. For evacuation in case of fire or similar circumstances With handheld microphone for sending live announcements Controls to activate emergency mode and send pre-recorded warning and evacuation messages. Ready to be installed on the front of the COMPACT audio matrix MICROPHONES MD-30ETH | MD-30C Microphone desk “local” 18 configurable keys sending messages to individual zones, groups of zones. Ethernet connection (MD-30ETH) Bus connection (MD-30C) max 16 max 4 MICROPHONES DC-700ETH Microphone desk “global or “local” Live recording or pre-recorded messages broadcasting through the Ethernet network Supervision of the PA/VA system Configuration of parameters. Fireman’s microphone functions Equivalent to a VACIE remote control unit. Sending notifications to zones / groups. Activation of pre-evacuation and evacuation prerecorded messages (EN 54). Activation of generic prerecorded messages Live announcements, with or without warning tone (gong). Music source connection and music program sending via Ethernet. Monitor speaker Alarm led System alarm list. MICROPHONES ME-200C Fireman's remote panel with microphone Remote equipment for sending emergency messages For evacuation in case of fire or similar circumstances Safety key Push buttons to activate the emergency mode. It incorporates warning microphone. POWER UNITS DA-500D2 | DA-500D4 Digital class D power units Digital power unit with 2 or 4 outputs of 500 W of RMS power at 100V. High energy efficiency and minimum heat generation (class D) Reduction of the rack space required Voltage, current and temperature monitoring and protection circuits Automatic disconnection to avoid possible overload, short circuit or overheating POWER SUPPLY MS-150 Power supply and switchover to emergency power supply (batteries not included) LC-XB12100P Sealed Pb battery 12 V DC, 100 Ah Rack format (19”) Monitoring the presence of the battery and its impedance Protects the battery from temperature variations Alarm messages via voltage-free contacts Up to 6 outputs for amplifier and 3 auxiliary outputs, protected by fuse All connectors are plug-in Built-in lightning protection IP INTERFACE IF-704ETH | IF-722ETH IF-704ETH IF-722ETH = COMPACT + 2 x UMX-SA = COMPACT + UMX-EA3 + UMX-SA Interface for connecting power units anywhere in the network It receives messages from global IP microphone desks and SIP telephones of a COMPACT system, as well as the general music channels UBS frontal input for music It has 16 GB for storing audio messages 1 20 2 19 NOISE SENSOR NS-CAN Noise sensor Bus connection, up to 16 units Sending the noise level measured in the particular location where it is placed Automatic adjustment of the volume of each zone according to the ambient noise. Microphone capsule in a weatherproof housing It’s possible to assign one or several sensors to one zone It’s also possible to assign a different weight to each sensor. Opcionalmente puede conectarse un micrófono externo SOFTWARE SCM-01 Setup and control software “call point” SCIN-01 integration software COM-PAM PA/VA server 24/7 COM-PCC PA/VA PC control SOFTWARE Call point | MENUS File Menu Exit Edit menu Screen Design Area Add Area Delete Area Rename Area Resize Area Zone Add Zone Delete Zone Group Add Group Delete Group Device Add Device Delete Device Image Add Background Image Delete Background Image View Meny Event Log Message Log Device Status Message Board State Board Information Board Zone Status Zoom Bar Group Menu New Group Group Information Schedule Menu New Message Schedule Message Time Schedule Information New Volume Schedule Volume Schedule Information Messages Menu Message Sequence/New Message Sequence Message Sequence/Message Sequence Information Managing prerecorded Messages (PC) Managing prerecorded Messages (Device) User Menu Change User New User User Info New Profile Profiles Info User Configuration Options Menu Language General Configuration General Optimus Status Log Levels Logs Backup Audio Settings PA Messages Play/Record Local Monitor / Record Key board short cuts User interface Configuration Setups Help Menu About… CERTIFICATE MUCHAS GRACIAS!!!!!!!!! GRACIAS THANKS VERY MUCH MARKETING