Bulletin No. A1225
January 15, 2004
RED THREAD® II Performance Plus™ PIPING
SIGNIFICANT FEATURES which make RED THREAD
II Performance Plus Piping Systems ideal:
•
Available in 8" - 24" diameters with bell x spigot end
configuration.
•
Pipe is constructed of fiberglass and amine cured epoxy
resin.
•
Its fiberglass and epoxy resin construction offers
internal and external corrosion resistance.
•
RED THREAD II Performance Plus piping has improved
flow characteristics compared to traditional materials.
•
It is lightweight and easy to install.
•
Pipe is rated at 450 psig static pressure at 200°F.
•
Pipe is manufactured in 39-foot random lengths.
Dimensional Data*
Nominal Pipe
Size (In.)
(In.)
8
10
12
14
16
18
20
24
Nominal I.D.
(In.)
(mm)
8.36
10.36
12.28
14.02
16.02
17.82
19.83
23.84
212
263
312
356
407
453
504
606
Nominal
Wall Thickness
(In.)
(mm)
Nominal O.D.
(In.)
(mm)
8.71
10.82
12.82
14.66
16.74
18.66
20.74
24.90
221
275
326
372
425
474
527
632
0.175
0.234
0.270
0.330
0.370
0.418
0.457
0.460
4.4
5.9
6.9
8.4
9.4
10.6
11.6
11.7
Nominal Weight
Capacity
(Lbs./Ft.)
(kg/m) (Gal/Ft.) (Cu.Ft./Ft.)
4.1
6.6
9.2
12.5
16.0
20.7
25.2
35.0
6.1
9.8
13.7
18.6
23.8
30.8
37.5
52.1
2.85
4.38
6.15
8.02
10.47
12.96
16.04
23.17
0.38
0.59
0.82
1.07
1.40
1.73
2.15
3.10
General Specifications
Nom.
Pipe
Size
(In.)
8
10
12
14
16
18
20
24
External Pressure(2)
Maximum Ratings
Min. Bending
Radius(1)
Entire
Temp. Range
(Ft.)
(m)
184
229
271
310
354
395
439
527
56
70
83
95
108
120
134
161
psig
MPa
@75°F
@210°F
@24°C
30
21
20
24
23
22
20
19
19
18
16
20
19
14
14
13
.207
.145
.138
.165
.159
.148
.141
.131
® and ™ Trademarks of Varco I/P, Inc.
© Copyright 2002, Varco L.P.
*
@99°C
.131
.124
.110
.138
.131
.099
.094
.088
All values are nominal. Tolerances or maximum/minimum limits can be obtained from Smith
Fibercast.
(1) Sharper bends should be eliminated to avoid stress concentration which could result in premature pipe failure under pressure conditions.
(2) Vacuum Service: A full vacuum within the pipe is equivalent to 14.7 psig (1.01 bars) external
pressure at sea level. Maximum external pressure ratings are based on test data obtained using ASTM D2924.
SMITH FIBERCAST • A VARCO COMPANY
2700 W. 65TH ST., LITTLE ROCK, AR 72209-8592 • 501-568-4010 • FAX 501-568-4465
25 S. MAIN ST., SAND SPRINGS, OK 74063 • 918-245-6651 • FAX 918-245-7566
RED THREAD II Performance Plus PIPING
ASTM D2996 Designation Codes at 75°F:
8"
10"
12"
14" - 16"
18" - 24"
RTRP-11AH1-2112
RTRP-11AH1-2114
RTRP-11AH1-2115
RTRP-11AH1-2116
RTRP-11AH1-2110
RED THREAD II Performance Plus pipe must
be joined using 8000 series adhesive and the
appropriate Smith Fibercast tapering tool.
Designation Codes for physical properties only; dimensions are not
in compliance with ASTM D2996
Average Physical Properties
Property
Axial Tensile – ASTM D2105
Ultimate Stress
Design Stress
Modulus of Elasticity
Value @ 75° F / @ 24°C
(psig)
(MPa)
10,300
2,575
1.82 x 106
Poisson’s Ratio
Value @ 210° F / @ 99° C
(psig)
(MPa)
71
17.8
12548
7,700
1,925
1.18 x 106
0.38
53
13.3
8136
0.38
Axial Compression – ASTM D695
Ultimate Stress
Design Stress
Modulus of Elasticity
33,300
8,325
1.26 x 106
230
57.4
8687
19,400
4,850
0.6 x 106
134
33.4
4137
Beam Bending – ASTM D2925
Ultimate Stress
Design Stress(1)
Modulus of Elasticity (long term)
23,000
2,875
1.46 x 106
158.6
19.8
10000
16,000
2,000
0.96 x 106
110
13.8
6630
34,000
234
43,500
300
89.9(2)
8,380(2)
57.8(2)
Hydrostatic Burst – ASTM D1599
Ultimate Hoop Tensile Stress
Hydrostatic Design – ASTM D2992,
Procedure A – Hoop Tensile Stress
Cyclic 150 x 106 Cycles
Coefficient of Linear Thermal Expansion
– ASTM D696
13,040(2)
0.88 x 10-5 in./in./°F
•
1.58 x 10-5 mm/mm/°C
0.23 BTU/(ft.)(hr.)(°F)
•
0.14 W/(m)(°C)
Specific Gravity – ASTM D792
1.8
•
1.8
Flow Factor – SF
Hazen-Williams Coefficient
150
•
150
Thermal Conductivity – ASTM D177
(1) Beam bending design stress is 1/8 of ultimate to account for combined stress (i.e. bending
and pressure).
8" - 16" product is
rated to 300 psig cyclic
per API Spec 15LR,
6th Edition, at 200°F.
SMITH FIBERCAST • A VARCO COMPANY
http://www.smithfibercast.com
(2) The hydrostatic design stress cyclic at 150°F is 10,450 psi, per ASTM D2992, Procedure
A. Based on complete data sets obtained at 150°F and 200°F, the extrapolated value at
75°F is 13,040 psi.
All dimensions listed above are nominal in nature and should only be
used for system layout and take off. Actual fittings and fabrication work
should be measured before bonding to ensure dimensional accuracy.
Smith Fibercast does not warrant and is in no way responsible for the installation of the goods and shall not be responsible for the workmanship
of any distributor, contractor or others involved in the installation of the
goods.
PRINTED IN U.S.A., 5M104
Descargar