Make sure your Adobe Acrobat Reader is up
to date in order to access the latest features
of this schematic.
SCHEMATIC FEATURES AND TIPS
GET
Adobe Acrobat Reader
SAVE
a copy of this schematic
THE BOOKMARKS PANEL WILL ALLOW YOU TO
QUICKLY NAVIGATE TO POINTS OF INTEREST.
THE FUNCTION ISOLATION TOOLS ISOLATE
CIRCUITS FOR TRACING HYDRAULIC LINES
Function Isolation Tools
Grids On/Off
All Circuits Off
STANDARD VIEW
All Circuits On
021 (Orange) (Pilot Pump Output)
032 (Red) (Main Pump Output)
577 (Lt Green) (Drain/Return Line)
Machine Views
Machine View - Front
Machine View - Rear
Implement Stack
UTILIZE HYPERTEXT TO NAVIGATE TO COMPONENTS AND THEIR MACHINE LOCATION QUICKLY. HYPERTEXT IS INDICATED BY TEXT THAT IS BLUE AND UNDERLINED.
021 (Orange) (Pilot Output)
CIRCUIT ISOLATED
CLICK HERE TO VIEW THE SCHEMATIC
SYMBOLS AND DEFINITIONS PAGE
ELECTRICAL SYMBOLS
T
Pressure
Switch
Temperature
Switch
Level
Switch
Circuit Breaker
BASIC HYDRAULIC SYMBOLS
Fluid
Conditioner
Pump
or Motor
Spring
Variability
(Adjustable)
HOTKEYS (Keyboard Shortcuts)
VIEW ALL CALLOUTS
WHEN ONLY ONE CALLOUT IS SHOWING ON A
MACHINE VIEW, CLICKING ON THIS BUTTON WILL
MAKE ALL OF THE CALLOUTS VISIBLE. THIS
BUTTON IS TYPICALLY LOCATED IN THE TOP RIGHT
CORNER OF EVERY MACHINE VIEW PAGE.
© 2021 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE
WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
FUNCTION
KEYS
Zoom In
Zoom Out
Fit to Page
Hand Tool
Find
“CTRL” / “+”
“CTRL” / “-”
“CTRL” / “0” (zero)
“SPACEBAR” (hold down)
“CTRL” / “F”
Search
“CTRL” / “SHIFT” / “F”
Due to different monitor sizes and PDF reader
preferences there may be some variance in linked
schematic locations. This document is best viewed at
a screen resolution of 1024 X 768.
SCHEMATIC SYMBOLS AND DEFINITIONS
INTERNAL PASSAGEWAYS
VALVES
ENVELOPES
Two Position
One Position
Three Position
PORTS
Two-way
Three-Way
FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
Infinite
Positioning
Two
Position
PARALLEL
FLOW
PUMPS
Unidirectional
Three
Position
Unidirectional
CONTROL
AB
AB
Single Acting
Shifted Position
Normal Position
Spring
Loaded
Fluid
Conditioner
Spring
(Adjustable)
Spring
Pressure
Compensation
Control
Valves
Line Restriction
(Variable)
Restriction
Line Restriction
(Fixed)
Line Restriction
Variable and Pressure
Compensated
2-Section
Pump
Attachment
Pump: Variable and
Pressure Compensated
Bidirectional
MOTORS
Double Acting
Infinite Position
CHECK
Basic
Symbol
Variability
FIXED DISPLACEMENT
P T
P T
Pump
or Motor
Bidirectional
VARIABLE DISPLACEMENT
NON- COMPENSATED
CYLINDERS
Four-Way
BASIC HYDRAULIC
COMPONENT SYMBOLS
FIXED DISPLACEMENT
CROSS
FLOW
ACCUMULATORS
Shuttle
Unidirectional
Bidirectional
VARIABLE DISPLACEMENT
NON- COMPENSATED
Pilot
Controlled
Spring Loaded Gas Charged
Unidirectional
Bidirectional
PILOT CONTROL
RELEASED PRESSURE
External Return
ROTATING SHAFTS
Internal Return
Unidirectional
Bidirectional
REMOTE SUPPLY PRESSURE
Simplified
Complete
Internal
Supply Pressure
Hydraulic Pneumatic
Energy Triangles
COMBINATION CONTROLS
Solenoid
Solenoid
or Manual
Solenoid
and Pilot
Solenoid and
Pilot or Manual
MEASUREMENT
LINES
Servo
Thermal
Detent
Crossing
Joining
Manual Shutoff
General Manual
Push Button
Pedal
Spring
Vented
Pressurized
Transducer
(Fluid)
Transducer
(Gas / Air)
M
Generator
Electric
Motor
Pressure
Switch
Pressure Switch
(Adjustable)
Temperature
Switch
Electrical
Wire
Return Above Fluid Level
Temperature
Switch
Level
Switch
Flow
Switch
Wire, Cable, or Harness Assembly Identification:
Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
AG-C4
111-7898
Part Number: for
Connector Plug
Plug
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine.
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure.
Its resistance changes to give an indication to the gauge of the temperature or pressure.
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay.
Solenoid: A solenoid is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet
when current flows through them. It also has an internal switch that places
the latch coil circuit open at the time the coil latches.
1
L-C12
3E-5179
2
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine.
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
a normally open reed switch; it opens the contacts of a normally closed reed switch.
Circuit Breaker
HARNESS AND WIRE SYMBOLS
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it.
© 2021 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE
WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
Return Below Fluid Level
T
Pressure
Switch
BASIC ELECTRICAL COMPONENT SYMBOLS
T
Flow
ELECTRICAL SYMBOLS
HYDRAULIC SYMBOLS - ELECTRICAL
G
Temperature
Pressure
FLUID STORAGE RESERVOIRS
MANUAL CONTROL
Push-pull Lever
MAIN AUX.
Receptacle
Pin or Socket Number
Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
harness (C1, C2, C3, ...)
L-C12
3E-5179
5A
Fuse (5 Amps)
Harness identification code:
This example indicates wire group 325,
wire 135 in harness "AG".
Component
9X-1123
Part Number
325-AG135 PK-14
Wire Gauge*
Wire Color
*Wire gauge is shown in AWG (American Wire Gauge)
but could also be shown in metric denoted with mm
1
2
Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
sockets and the receptacle contains all pins.
1
2
Sure-Seal connector: Typical representation
of a Sure-Seal connector. The plug and receptacle
contain both pins and sockets.
M0132805
November 2021
966 and 972 Wheel Loader
Cooling System
EL91-UP
W991-UP
J8R1-UP
M7P1-UP
PUBLICATIONS.CAT.COM
© 2021 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
Schematic
Location
A-7
Machine
Location
1
Block As - Engine
B-5
2
Cooler Gp - Transmission Oil
B-4
3
Engine - Head / Thermostat Housing
E-6
4
Filter Gp - Engine Oil (Cooler)
B-6
5
Pump Gp - Water
C-4
6
Pump Gp - Water (Inlet Bonnet)
C-4
7
Radiator Gp
C-1
8
Sensor Gp - Temperature (Coolant)
E-7
9
Tank Gp - Coolant (Shunt)
F-1
10
Valve As - Fluid Sampling
A-5
11
Description
Air Conditioner and Mounting Gp - Cab Heater
TAP LOCATION
Tap
Number
SOS
Description
Fluid Sampling Port
Schematic
Location
A-5
7
6
5
4
3
2
1
NOTE: DUAL PORT CONFIGURATION
CAP PRESSURE 15 PSI (1 BAR)
VENT LINE
F
F
OVERFILL
(9) SENSOR GP
TEMPERATURE
(COOLANT)
234-5012
E
(4) ENGINE HEAD /
THERMOSTAT HOUSING
523-4232
VENT LINE
(10) TANK GP - SHUNT
486-0884
C9.3B ENGINE
E
(6) PUMP GP - WATER
346-9561
D
D
M0132805
24 Page, (Dimensions: 34 inches x 28 inches
SHUNT LINE
(7) PUMP GP
WATER (INLET BONNET)
278-0244
C
(8) RADIATOR GP
599-2434
(5) FILTER GP - ENGINE
OIL (COOLER)
450-1117
B
(2) BLOCK AS
ENGINE
277-7261
C
B
JACKET WATER HEATER
(OPTIONAL )
(3) COOLER GP
TRANSMISSION OIL
364-9906
CAB HEATER
LINE PATTERNS
Pressure Line
Pilot / Load Sensing Pressure
Drain / Return Lines
DRAIN
(1) AIR CONDITIONER
A
AND MOUNTING GP
(CAB HEATER)
595-1961
7
Air Line
Component Group
CALLOUTS
Taps (Pressure, Sampling, Sensor - by letter)
YY
(11) VALVE AS
FLUID SAMPLING
(SOS PORT)
183-7264
6
Do not operate or work on this product unless you have
read and understood the instruction and warnings in the
relevant Operation and Maintenance Manuals and
relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or
death. Proper care is your responsibility.
SOS
CAB HEATER CIRCUIT
HEATED COOLANT CIRCUIT
DRAIN / RETURN LINE
COOLING CIRCUIT
4
3
DL
Callout Number
(Machine Location from
Component LocationsTable)
D
A
Connectors (By letter)
(52) VALVE GP - CONTROL
138-1234
Part Number
Component
Name
THIS SCHEMATIC IS FOR THE 966 AND 972 WHEEL LOADER COOLING SYSTEM
MEDIA NUMBER: M0132805
SCHEMATIC PART NUMBER: 570-8383, CHANGE: 00, VERSION: -
COOLING CIRCUIT COLOR DESCRIPTIONS
5
DL
2
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
in neutral and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
1
MACHINE - LEFT VIEW
VIEW ALL CALLOUTS
5
4
9
10
6
SOS
2
11
7
3
MACHINE - RIGHT VIEW
VIEW ALL CALLOUTS
1
8