— Introduction to MV Switchgear Primary and Secondary AIS & GIS [email protected], +353 87 820 1376 — Types of MV switchgear – Primary AIS (Air Insulated Switchgear) PAIS – Primary GIS (Gas Insulated Switchgear) PGIS – Secondary AIS (Air Insulated Switchgear) SAIS – Secondary GIS (Ring Main Units) RMU May 11, 2022 Slide 2 — Types of MV switchgear MV switchgear comparison overview Primary AIS & GIS Secondary AIS Ring Main Unit Rated Voltage Up to 40.5kV Up to 24kV Up to 36kV Rated current 4000A 1250A max 630A max Circuit breaker ratings 4000A 630-1250A 200A Switch disconnect ratings 2500A (GIS only) 1250A 630A Short time current Up to 50kA 3 seconds 21kA 1 second 16kA 1 second Configuration Withdrawable or Fixed Removable CB Fixed Summary 4000A Withdrawable (AIS) Fixed (GIS) 40kA 1250A Fixed or Removable CB 21kA 630A Fixed 16kA May 11, 2022 Slide 3 — IEC 62271-200 New definitions and classifications of MV switchgears The latest revision of switchgear classification rules is focused on the user point of view, in particular on aspects like service and maintenance of the switchgear, according to international best practice, from installation to end of life de-commissioning In this context the Loss of Service Continuity has been chosen as a fundamental parameter for the user May 11, 2022 Slide 4 — LSC (Loss of Service Continuity) A category defining the possibility to keep other compartments and/or functional units energized when opening a main circuit compartment 1. LSC1 The whole switchgear shall be put out of service for opening a main circuit compartment for normal operation and/or normal maintenance or for having access to any switchgear components 2. LSC2A The same as LSC1 with the exception that the main busbars and the functional units adjacent to the one in maintenance can remain energized 3. LSC2B The same as LSC2B with the exception that the cable compartment can remain energized May 11, 2022 Slide 5 — LSC1 Compartments without any physical and electrical segregation among them B A Medium Voltage Switchgear – Lateral Section May 11, 2022 Slide 6 A Circuit Breaker Compartment Feeder Compartment Busbar Compartment B Auxiliary compartment — LSC2A Busbar and apparatus compartments physically and electrically segregated B C A Medium Voltage Switchgear – Lateral Section May 11, 2022 Slide 7 A Circuit Breaker Compartment Feeder Compartment B Busbar Compartment C Auxiliary Сompartment — LSC2B Busbar, feeder and apparatus compartments physically and electrically segregated B D A C Medium Voltage Switchgear – Lateral Section May 11, 2022 Slide 8 A Circuit Breaker Compartment B Busbar Compartment C Feeder Compartment D Auxiliary compartment — Primary AIS — Air insulated switchgear for primary applications UniGear ZS1 UniGear ZS1 For any application in Utilities, Power Plants, Data Centers, Industry, Oil & Gas, Marine, etc. IEC 62271-200 type tested LSC2B Fully Compartmentalized Internal arc classified from Front, Lateral, Rear Single or double busbar solution Fully accessible from the front Mechanical Safety Interlocks Metal Shutters operated by CB movement Closed door apparatus racking May 11, 2022 Slide 10 — UniGear ZS1 Design of a typical functional unit IEC 62271-200: Metal enclosed LSC2B-PM Enclosure IP4X (IP3XD) Internal partitioning IP2X Busbar compartment – tool-based access for maintenance; ready for future extensions Low voltage compartment Circuit breaker compartment – interlock-controlled access (can be combined also with procedure-based access) May 11, 2022 Slide 11 1. Cable compartment – interlockcontrolled access (can be combined also with procedure-based access) — Unigear ZS1 Shutters 1. Control Wiring Socket 2. Upper Shutter (closed) 3. Lateral Cover 4. Lower Shutter (closed) 5. Travel Rail May 11, 2022 Slide 12 View of fixed contacts with shutters opened. NOTE: Current Sensors fitted. Shutters are opened and closed by movement of the Circuit Breaker. 1. 2. 3. 4. Upper Shutter (opened) Contact System Fixed Contact Housing Contact Arm — UniGear ZS1 Electrical characteristics Rated voltage [kV] 12 17.5 24 Test voltage (50-60 Hz/1 min) [kV] 28 38 50 Impulse withstand voltage [kV] 75 95 125 Rated frequency [Hz] 50/60 50/60 50/60 Rated short-time withstand current [kA 3s] Up to 50 50 31.5 Peak withstand current [kA] Up to 125 125 80 Internal arc withstand current [kA 1s] Up to 50 50 31.5 Rated current of the main busbars [A] Up to 4000 4000 3150 Rated circuit-breaker thermal current [A] Up to 4000 4000 3150 630 630 630 1250 1250 1250 1600 1600 1600 2000 2000 2000 2500 2500 2300 3150 3150 2500 3600 3600 2500 4000 4000 3150 Feeders rated current with natural ventilation Feeders rated current with forced ventilation May 11, 2022 Slide 13 [A] — Circuit breakers for UniGear ZS1 UniGear ZS1 is used solely with ABB breaking technologies Vacuum and SF6 breakers available VD4 Vacuum technology: VD4 – embedded poles, spring type actuator for 30,000 operations VSC – fused vacuum contactor for motor feeders HD4 SF6 technology: HD4 – SF6 Auto Puffer, motor operated, spring wound circuit breaker May 11, 2022 Slide 14 — Current and voltage metering in UniGear ZS1 UniGear ZS1 is equipped with ABB metering instruments Current and voltage metering sensors and transformers available Conventional CTs and VTs: TPU – support-type CTs KOKS – ring-type CTs BD ring-type CTs TJC – single-pole VTs without fuses TJP – single-pole VTs with fuses KOLMA, KOLA, ... – core balance CTs May 11, 2022 Slide 15 — Protection and control for UniGear ZS1 UniGear ZS1 can be equipped with full range of ABB protection devices Relion Range 615 series – Feeder, Motor, Transformer and Line differential protection and control IEDs – Arc protection embedded (3 channels) – Withdrawable and compact design – Web browser based user interface Relion Range 630 series – Feeder, Motor and Transformer protection and control IEDs – Advanced programmable control schemes – 8 controllable primary apparatus – Web browser based user interface May 11, 2022 Slide 16 — Internal Arc classification UniGear ZS1 is Internal Arc Classified (IAC) in compliance with IEC 62271200, Annex A, in all five criteria Accessibility type IAC AFLR – A – authorized personnel only – F, L, R – front, lateral and rear Type tested as per the rated fault conditions, i.e. up to IAC AFLR 50kA/1s Internal arc test in laboratory May 11, 2022 Slide 17 Pressure release flaps — Internal Arc Test – five criteria Internal arc classified IAC AFLR according to the IEC 62271-200 Annex A UniGear is in full accordance to all the five criteria: 1. The doors of the switchboard must remain closed and no opening of the cover panels must occur 2. Any part of the switchboard which may be hazardous for personnel must not be ejected 3. No holes must appear in the external housing of the switchboard in any parts accessible to personnel 4. The vertically and horizontally arranged fabric indicators placed outside the switchboard must not get burnt 5. All the switchboard earthing connections must remain effective Front, rear and lateral arc resistance May 11, 2022 Slide 18 — Internal Arc protection measures For full IAC AFLR classification, additional protection is by means of a pressure relief channel, installed above the switchgear pressure release flaps The application may vary as per particular situation, for example: – Gas exhaust channel with outlets away from the switchgear room – tested up to 50kA/1s – Channels with top chimneys, without need for external outlets – tested up to 50kA/0,5s 2 3 1 4 Gas exhaust channels for full IAC protection May 11, 2022 Slide 19 5 6 — UniGear Product Portfolio – UniGear ZS1 (12-17,5kV and 24kV) – Standard single busbar version – Duplex – double busbar version with two CBs – Double BusBar – one CB and two line disconnectors – UniGear 550 (12-17,5kV) - Compact Version – UniGear 500R (12kV) - Compact, with fixed CB and ENA certification – Unigear MCC (7,2kV) – Is limitor (12-17,5kV and 24kV) May 11, 2022 Slide 20 — Primary GIS — Primary GIS – ZX Range ZX0 ZX0.2 ZX1.2 ZX2 Up to Up to Up to Up to 1250A 25kA 2500A 31.5kA 2500A 31.5kA 4000A 40kA 24kV 36kV 40.5kV 40.5kV May 11, 2022 Slide 22 — Gas-insulated switchgear Type ZX0.2 Design – Metal-enclosed and gas-tight – Each panel consists of one gas compartment as a sealed pressure system – SF6 gas-insulated – Stainless steel enclosures – Coupling of units by solid-insulated busbars without gas handling – Cable access from the front – Outer cone cable connections – Panel widths on a 600 mm grid for all functions and current ratings – Wall or free-standing installation May 11, 2022 Slide 23 — Gas-insulated switchgear Type ZX0.2 13 1 12 11 2 3 10 7 6 9 8 4 5 1. Removable low voltage compartment 2. Disconnector operating mechanism 3. Mechanism bay with operator controls 4. Circuit-breaker operating mechanism 5. Cable connector 6. Window-type current transformer 7. Bushing with outer cone 8. Isolatable voltage transformer on the cable 9. Pressure relief disk 10. Vacuum circuit-breaker 11. Three position disconnector 12. Busbars 13. Plug-in busbar voltage transformers May 11, 2022 Slide 24 — Gas-insulated switchgear Type ZX0.2 Advantages – Partitioned function compartments provide maximum safety – Completely shockproof arrangement – High voltage section totally independent of environmental influences – Maximum availability for the operator – Very Compact, compared to AIS – Minimum maintenance requirement – Longer life than other system types May 11, 2022 Slide 26 — Secondary AIS — Secondary AIS UniSec Main Features – SF6 switch-disconnector GSec – Removable circuit breaker VD4/R_Sec and HD4/R_Sec type in vacuum type and SF6 insulator – Withdrawable circuit breaker Vmax option – Contactor VSC/P – Wide portfolio available of units – LSC2A & LSC2B service continuity classification – Internal arc IAC AFLR May 11, 2022 Slide 28 — Electrical Characteristics Rated voltage kV 12 17.5 24 Test voltage (50-60 Hz x 1 min) kV 28 38 50 Impulse withstand voltage kV 75 95 125 Rated frequency Hz 50 50 50 Rated main busbar current A 630/800/1250 630/800/1250 630/800/1250 Rated normal current of apparatus – VD4-HD4 removable circuit-breaker A 630/800 630/800 630 – GSec gas switch-disconnector A 630/800 630/800 630 – Vmax withdrawable A 630/1250 630/1250 Rated short time withstand current kA (3s) 16/21/251 16/21/251 16/21/251 Peak current kA 40/50/63 40/52.5/631 40/52.5 Internal arc withstand current (IAC AFLR) kA (1s) 12,5/16/212 12,5/16/212 12,5/16/2 May 11, 2022 Slide 29 1. 25 kA 2 s 25 kA 3 s for withdrawable CB panel 2. 25 kA 1s for 12-17,5kV withdrawable CB panel — Typical Panels removable CB units 1. SBC = switch-disconnector unit with circuit-breaker Standard accessories – voltage indicators 2. SBS = switch-disconnector unit with circuit-breaker for sectionalizing M M B C May 11, 2022 A B C Slide 30 A Optional accessories – motor operation device – wide range of protection relays – pressure indication – CT’s and VT’s (SBC) – CT’s (SBS & SBR) – surge arresters Dimensions A 750 mm B 1700 mm – 1922 mm with LV comp. 1922 mm with gas absorbers 2032 mm with gas ducts C 1187 mm 1325 mm with gas absorbers and LV 1310 mm with gas ducts and LV — Removable circuit-breakers 1. VD4/R-Sec available also with REF 601 on board 2. HD4/R-Sec available also with REF 601 on board UniSec can be equipped with vacuum or gas circuit-breakers with lateral operating mechanism. The circuit-breaker can be fully remote controlled Protection relay type REF601 can be integrated in the circuit-breaker, including current sensors for current measuring type KECA May 11, 2022 Slide 31 — Ring Main Units — SafeRing SafeRing Ring Main Units: General – 12/24/36 kV 630 A – Integrated control and monitoring unit – SF6 – insulated – Transformer protection • fixed vacuum circuit breaker • fuse switch disconnector May 11, 2022 Slide 33 — SafeRing SafeRing Ring Main Units: General Rated voltage 12 kV 17.5 kV 24 kV Rated Current 630A 630A 630A Basic Insulation Level 75kV 95kV 125kV Short Circuit, 3 sec. 21kA 21kA 16kA Making Capacity 52,5kA 40kA 40kA Max Fuse Size (IEC 60420) 125A 63A 63A SafeRing is tested according to the following IEC standards: 60056, 60129, 60265, 62271-200, 60420, 60694 May 11, 2022 Slide 34 — SafeRing SafeRing Ring Main Units: Standard Configurations May 11, 2022 DV CCV CCCV CCCC Slide 35 C = cable feeder 630 A load break disconnect V = 200 A Vacuum CB CCVV — Safering SafeRing Ring Main Units: Dimensions 1021 765 1345 100 595 490 2 way unit 686 mm 3 way unit 1021 mm 4 way unit 1346 mm May 11, 2022 Slide 36 1. Fixing bracket — Recent Developments — UFES (Ultra Fast Earthing Switch) – ABB has developed an extremely fast-acting earthing switch, which opens the possibility for new arc protection concepts for medium voltage switchgear systems – The fast-acting earthing switch UFES is an innovative combination of the ABB technologies vacuum interrupter and Is-limiter – The reliable detection of current and light, in combination with the extreme short operation time, ensures immediate extinguishing of every arc. This prevents the switchgear system to be protected against thermal and mechanical damages May 11, 2022 Slide 38 — UFES (Ultra Fast Earthing Switch) Features of UFES: Benefits of UFES: – Reliable detection of current and light of the internal arc – Increased system availability – Arc fault duration ≤ 4 ms – Reduction of downtimes and repair costs – Final clearing of the fault current by the upstream circuit-breaker – Increased operator safety under maintenance conditions May 11, 2022 Slide 39 — UniGear ZS1 Digital 24 kV, 3150 A, 31.5 kA – Busbar arrangement KECA 80 C184 • Single busbar Protection relay with IEC 61850 – Current sensors • KECA 80 C184 • KECA 80 C216 KEVA 24 B20 Current sensor – Voltage sensors • KEVA 24 B20 Voltage sensor – Protection and control relays • Relion 615 series (REF615, RED615, REM615) • Relion 620 series (REF620, REM620) May 11, 2022 Slide 40 — Adapter, to combine Current and Voltage signals into one RJ-45 Current sensor Protection relay Adapter Shielded cable with RJ45 Voltage sensor May 11, 2022 Slide 41 — UniGear Digital … – Wide functionality with minimum product range – Linear characteristic – no saturation – Current accuracy class 0.5 / 5P – Voltage accuracy class 0.5 / 3P – Late changes possible during design – Eliminates risk of ferro-resonance – Smaller and lighter devices – Error-free connection and safe secondary signal – Shorter lead times – Less technical parameters to specify – Busbar voltage measuring easily achieved May 11, 2022 Slide 42 — World’s first gas-insulated switchgear (GIS) installation with new eco-efficient gas mixture, AirPlus Oerlikon substation (ewz) Zurich, Switzerland ABB Technology and Solution Equipment in pilot substation includes: The fluoroketone-based SF6 alternative gas mixture is a chemical compound developed for switchgear applications in collaboration with 3M – 8 bays of 170 kV GIS It has a dielectric performance very similar to SF6 but with a very low GWP (Global Warming Potential) May 11, 2022 Slide 43 – 50 panels of 24 kV GIS — ABB in Ireland At a glance Lisburn, EL Local regional office EL Product supply & suppor Dundalk, PAPI IAPI QCS technology centre R&D for QCS product line Sales & marketing support 180 5 People work for ABB in Ireland Sites where products are sold, serviced or engineered Want to know more? [email protected] www.abb.ie Skilled and experienced Irish team, backed by global networks May 11, 2022 Slide 44 Dublin, HQ EL, PA, & MO Automation, Power, Sales, Engineering, & Management Dublin, Cylon Controls Production & Service Cork PAEN Process Automation Project delivery — ABB Ireland Registered Training Provider with Engineers Ireland ABB Electrification ABB Motion 1. Technical overview of LV Switchgear and Panel Selection. 1. Harmonics, VSDs & Mitigation technologies 2. LV Selectivity / Discrimination 2. IE5 Synchronous Reluctance Drive and Motor Package 3. IEC61439 Standard for Circuit Breakers & Assemblies 4. Arc Fault Detection Devices (New MCBs & RCBOs) 5. Electric Vehicle Charging Infrastructure 6. The Fundamentals & Principles of Building Energy Management Systems 7. Introduction to MV Switchgear 8. Building Services Integration BACnet and other options 9. IIoT for Electrical installations 10. Building Automation – KNX universal protocol & DALI Click here to view ABB offering on Engineers Ireland May 11, 2022 Slide 45 David Supple Product Marketing Director Electrification Distribution Solutions ABB Ltd. Belgard Road, Tallaght, Dublin 24, Ireland Mobile: +353 87 820 1376 Email: [email protected]
0
Puede agregar este documento a su colección de estudio (s)
Iniciar sesión Disponible sólo para usuarios autorizadosPuede agregar este documento a su lista guardada
Iniciar sesión Disponible sólo para usuarios autorizados(Para quejas, use otra forma )