EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W Lab ID#: AD19850109 Report: 20PS815A Receipt Date: Sep 17, 2019 Test Date: Sep 16, 2019 Report Date: Sep 19, 2019 DUT INFORMATION DUT SPECIFICATIONS Brand XPG Rated Voltage (Vrms) 100-240 Manufacturer (OEM) Channel Well Technology Rated Current (Arms) 12-6 Series Core Reactor Gold Rated Frequency (Hz) 47-63 Model Number Rated Power (W) 850 Serial Number Type ATX12V DUT Notes Cooling 120mm Fluid Dynamic Bearing Fan (HA1225H12F-Z) Semi-Passive Operation ✗ Cable Design Fully Modular TEST EQUIPMENT Chroma 63601-5 x4 Electronic Loads Chroma 63600-2 x2 63640-80-80 x20 63610-80-20 x2 AC Sources Chroma 6530, Keysight AC6804B Power Analyzers N4L PPA1530 x2 Sound Analyzer Bruel & Kjaer 2270 G4 Microphone Bruel & Kjaer Type 4955-A Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2 Tachometer UNI-T UT372 x2 Digital Multimeter Keysight U1273AX, Fluke 289, Keithley 2015 - THD UPS CyberPower OLS3000E 3kVA x2 Transformer 3kVA x2 All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 1/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W RESULTS Temperature Range (°C /°F) 30-32 / 86-89.6 ErP Lot 3/6 Ready ✓ (EU) No 617/2013 Compliance ✓ ALPM (Alternative Low Power Mode) compatible ✓ 115V 230V Average Efficiency 89.299% Average Efficiency 91.268% Efficiency With 10W (≤500W) or 2% (>500W) 74.172 Average Efficiency 5VSB 78.881% Average Efficiency 5VSB 79.524% Standby Power Consumption (W) 0.0574353 Standby Power Consumption (W) 0.0362833 Average PF 0.961 Average PF 0.988 Avg Noise Output 25.79 dB(A) Avg Noise Output 26.79 dB(A) Efficiency Rating (ETA) PLATINUM Efficiency Rating (ETA) PLATINUM Noise Rating (LAMBDA) A- Noise Rating (LAMBDA) A- POWER SPECIFICATIONS Rail Max. Power 3.3V 5V 12V 5VSB -12V Amps 22 22 70.8 3 0.3 Watts 120 850 15 3.6 Total Max. Power (W) 850 HOLD-UP TIME & POWER OK SIGNAL (230V) Hold-Up Time (ms) 20.6 AC Loss to PWR_OK Hold Up Time (ms) 19 PWR_OK Inactive to DC Loss Delay (ms) 1.6 All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 2/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W CABLES AND CONNECTORS Modular Cables Description Cable Count Connector Count (Total) Gauge In Cable Capacitors ATX connector 20+4 pin (650mm) 1 1 16-20AWG No 4+4 pin EPS12V (650mm) 2 2 16AWG No 6+2 pin PCIe (650mm+150mm) 2 4 16-18AWG No 6+2 pin PCIe (650mm) 2 2 16AWG No SATA (500mm+145mm+145mm+145mm) 3 12 18AWG No 4-pin Molex (500mm+150mm+150mm+150mm) 1 4 18AWG No All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 3/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W General Data Manufacturer (OEM) CWT PCB Type Double Sided Primary Side Transient Filter 4x Y caps, 2x X caps, 2x CM chokes, 1x MOV Inrush Protection NTC Thermistor & Relay Bridge Rectifier(s) 2x GBU15L06 (600V, 15A @ 115°C) APFC MOSFETS 2x Infineon IPA60R125P6 (600V, 19A @ 100°C, 0.125Ohm) & 1x SPN5003 FET (for reduced no-load consumption) APFC Boost Diode 1x CREE C3D10060A (600V, 10A @ 150°C) Hold-up Cap(s) 1x Nippon Chemi-Con (420V, 680uF, 2,000h @ 105°C, KMZ) Main Switchers 2x Infineon IPA60R125P6 (600V, 19A @ 100°C, 0.125Ohm) APFC Controller Champion CM6500UNX Resonant Controllers Champion CU6901V Topology Primary side: Half-Bridge & LLC converter Secondary side: Synchronous Rectification & DC-DC converters Secondary Side +12V MOSFETS 5V & 3.3V 8x Inte ational Rectifier IRFH7004PBF (40V, 164A @ 100°C, 1.4mOhm) DC-DC Converters:2x UBIQ QM3054M6 (30V, 61A @ 100°C, 4.8mOhm) & 2x UBIQ QN3107M6N (30V, 70A @ 100°C, 2.6mOhm) PWM Controllers: ANPEC APW7159C Electrolytics: 8x Nippon Chemi-Con (4-10,000h @ 105°C, KY), 2x Nippon Chemi-Con (105°C, W), 1x Nippon Chemi-Con (1-5,000h Filtering Capacitors @ 105°C, KZE), 1x Rubycon (4-10,000h @ 105°C, YXJ) Polymers: 25x FPCAP Supervisor IC Weltrend WT7502 (OVP, UVP, PG, SCP) Fan Model Hong Hua HA1225H12F-Z (120mm, 12V, 0.58A, Fluid Dynamic Bearing Fan) 5VSB Circuit Rectifier 1x Galaxy Microelectronics D10PS45L SBR (45V, 10A) & InPower Semiconductor ISD04N65A (650V, 4A, 2.5Ohm) Standby PWM Controller On-Bright OB5282CP All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 4/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE INFO The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used 5VSB EFFICIENCY INFO This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 5/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W 5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC) Test # 5VSB DC/AC (Watts) 0.045A 0.228 1 Efficiency PF/AC Volts 0.032 72.152% 5.062V 0.316 0.090A 0.456 2 115.15V 0.059 76.510% 5.061V 0.596 0.550A 2.778 3 115.15V 0.258 80.035% 5.050V 3.471 1.000A 5.039 4 115.14V 0.346 79.782% 5.038V 6.316 1.500A 7.537 5 115.14V 0.395 79.833% 5.024V 9.441 3.000A 14.951 6 115.14V 0.457 78.615% 4.984V 19.018 115.15V 5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC) Test # 5VSB DC/AC (Watts) 0.045A 0.228 1 Efficiency PF/AC Volts 0.011 66.087% 5.062V 0.345 0.090A 0.456 2 230.33V 0.019 72.266% 5.061V 0.631 0.550A 2.777 3 230.33V 0.102 78.093% 5.048V 3.556 1.000A 5.037 4 230.34V 0.167 79.323% 5.037V 6.350 1.500A 7.535 5 230.33V 0.222 79.710% 5.023V 9.453 3.000A 14.948 6 230.33V 0.319 79.761% 4.983V 18.741 230.33V All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 6/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W 115V All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 7/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W EFFICIENCY GRAPH 115V INFO This graph depicts the PSU’s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations NOISE GRAPH 115V INFO The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 8/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W VAMPIRE POWER -115V INFO This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 9/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W 10-110% LOAD TESTS 115V Test # 1 2 3 4 5 6 7 8 9 10 11 CL1 CL2 DC/AC 12V 5V 3.3V 5VSB 5.252A 1.979A 1.992A 0.993A 84.996 12.068V 5.058V 3.314V 5.040V 98.562 11.527A 2.969A 2.987A 1.192A 169.483 12.022V 5.056V 3.312V 5.035V 187.019 18.201A 3.465A 3.473A 1.393A 254.605 12.010V 5.054V 3.310V 5.028V 277.551 24.880A 3.961A 3.991A 1.593A 339.794 12.001V 5.051V 3.308V 5.022V 370.741 31.233A 4.954A 4.993A 1.795A 425.122 11.994V 5.048V 3.305V 5.016V 466.835 37.510A 5.951A 5.996A 1.997A 509.669 11.993V 5.043V 3.302V 5.009V 564.902 43.615A 6.950A 7.002A 2.200A 594.989 12.057V 5.039V 3.299V 5.001V 663.916 49.955A 7.948A 8.011A 2.404A 680.336 12.049V 5.035V 3.296V 4.994V 765.540 56.708A 8.449A 8.500A 2.405A 765.284 12.040V 5.032V 3.294V 4.992V 867.841 63.210A 8.952A 9.024A 3.016A 850.126 12.030V 5.028V 3.291V 4.974V 973.833 70.285A 8.955A 9.029A 3.017A 934.894 12.025V 5.026V 3.290V 4.973V 1082.019 0.158A 14.005A 14.001A 0.000A 118.805 12.053V 5.049V 3.299V 5.073V 141.770 70.872A 1.003A 0.999A 1.000A 866.104 12.032V 5.038V 3.301V 5.021V 988.377 (Watts) Fan Speed PSU Noise Temps PF/AC (RPM) (dB[A]) (In/Out) Volts 86.236% 659 10.1 40.02°C 0.980 44.27°C 115.17V 90.623% 663 10.2 40.74°C 0.986 45.75°C 115.17V 91.733% 666 10.3 41.33°C 0.991 47.35°C 115.17V 91.653% 669 10.4 41.81°C 0.988 48.37°C 115.16V 91.065% 1010 21.5 42.58°C 0.989 49.85°C 115.16V 90.223% 1260 28.2 42.70°C 0.991 50.91°C 115.15V 89.618% 1512 32.2 43.40°C 0.992 52.53°C 115.15V 88.870% 1817 38.8 43.81°C 0.993 53.29°C 115.15V 88.183% 2000 42.0 44.60°C 0.994 54.75°C 115.15V 87.297% 2171 43.5 45.52°C 0.994 56.22°C 115.16V 86.403% 2293 45.9 46.64°C 0.995 58.30°C 115.16V 83.801% 1041 22.3 42.48°C 0.985 50.31°C 115.18V 87.629% 2245 44.5 45.91°C 0.994 56.96°C 115.16V Efficiency All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 10/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W 20-80W LOAD TESTS 115V Test # 12V 5V 3.3V 5VSB 1.216A 0.496A 0.482A 0.198A DC/AC Efficiency (Watts) 11.969V 5.060V 3.317V 5.057V 26.121 2.486A 0.991A 0.996A 0.396A 40.094 9.4 0.945 81.041% 11.979V 5.057V 3.315V 5.051V 49.474 3.639A 1.482A 1.478A 0.595A 59.542 5.058V 3.314V 5.048V 71.765 4.897A 1.979A 1.991A 0.793A 79.950 9.5 0.962 82.968% 12.131V 646 115.17V 3 651 9.8 115.17V 0.977 4 86.097% 5.044V 641 PF/AC Volts 115.18V 2 3.314V (dB[A]) 0.866 75.277% 5.058V PSU Noise (RPM) 19.663 1 12.118V Fan Speed 656 9.9 92.860 115.17V RIPPLE MEASUREMENTS 115V Test 12V 5V 3.3V 5VSB Pass/Fail 10% Load 5.5 mV 5.2 mV 11.1 mV 6.9 mV Pass 20% Load 10.1 mV 5.3 mV 11.7 mV 7.0 mV Pass 30% Load 8.5 mV 5.6 mV 12.4 mV 6.8 mV Pass 40% Load 9.3 mV 6.7 mV 14.1 mV 7.5 mV Pass 50% Load 9.3 mV 8.1 mV 18.2 mV 8.2 mV Pass 60% Load 14.3 mV 14.7 mV 34.2 mV 38.2 mV Pass 70% Load 16.2 mV 14.9 mV 36.7 mV 39.2 mV Pass 80% Load 16.2 mV 15.4 mV 35.7 mV 39.0 mV Pass 90% Load 17.2 mV 15.4 mV 36.3 mV 41.1 mV Pass 100% Load 18.9 mV 11.4 mV 25.2 mV 17.5 mV Pass 110% Load 19.7 mV 12.5 mV 26.7 mV 19.4 mV Pass Crossload 1 13.5 mV 6.1 mV 21.1 mV 11.9 mV Pass Crossload 2 17.8 mV 13.9 mV 28.6 mV 36.6 mV Pass All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 11/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W 230V All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 12/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W EFFICIENCY GRAPH 230V INFO This graph depicts the PSU’s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations NOISE GRAPH 230V INFO The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 13/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W VAMPIRE POWER -230V INFO This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 14/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W 10-110% LOAD TESTS 230V Test # 1 2 3 4 5 6 7 8 9 10 11 CL1 CL2 DC/AC 12V 5V 3.3V 5VSB 5.253A 1.978A 1.991A 0.992A 85.002 12.069V 5.059V 3.314V 5.040V 97.530 11.528A 2.969A 2.990A 1.192A 169.495 12.021V 5.056V 3.312V 5.035V 184.631 18.202A 3.465A 3.473A 1.392A 254.615 12.010V 5.054V 3.310V 5.029V 273.460 24.889A 3.962A 3.990A 1.593A 339.805 11.997V 5.051V 3.308V 5.022V 363.848 31.241A 4.955A 4.993A 1.795A 425.130 11.991V 5.048V 3.305V 5.016V 456.902 37.515A 5.950A 5.998A 1.997A 509.663 11.991V 5.044V 3.302V 5.009V 550.844 43.623A 6.948A 7.002A 2.200A 594.991 12.055V 5.039V 3.299V 5.002V 645.540 49.960A 7.946A 8.012A 2.403A 680.337 12.048V 5.035V 3.296V 4.995V 742.589 56.723A 8.450A 8.500A 2.404A 765.295 12.037V 5.032V 3.294V 4.992V 839.845 63.220A 8.952A 9.025A 3.016A 850.070 12.027V 5.028V 3.292V 4.974V 938.586 70.301A 8.955A 9.029A 3.017A 934.884 12.022V 5.027V 3.290V 4.973V 1038.380 0.159A 14.003A 14.000A 0.000A 118.818 12.055V 5.049V 3.300V 5.074V 140.912 70.869A 1.004A 1.001A 1.000A 865.867 12.029V 5.038V 3.301V 5.021V 951.779 (Watts) Fan Speed PSU Noise Temps PF/AC (RPM) (dB[A]) (In/Out) Volts 87.155% 662 10.2 40.25°C 0.858 44.94°C 230.37V 91.802% 663 10.2 40.62°C 0.937 45.69°C 230.37V 93.109% 666 10.3 41.41°C 0.962 46.96°C 230.37V 93.392% 667 10.3 41.60°C 0.970 48.08°C 230.37V 93.046% 948 19.3 42.19°C 0.977 49.46°C 230.37V 92.524% 1248 31.2 42.70°C 0.980 50.56°C 230.38V 92.170% 1490 32.2 43.27°C 0.982 51.76°C 230.37V 91.617% 1814 38.8 43.64°C 0.984 52.53°C 230.37V 91.123% 2001 42.0 44.57°C 0.985 54.15°C 230.37V 90.569% 2237 44.4 45.97°C 0.986 56.24°C 230.38V 90.033% 2294 45.9 47.03°C 0.987 58.07°C 230.37V 84.321% 1122 24.4 42.00°C 0.917 49.55°C 230.38V 90.974% 2252 44.7 45.55°C 0.986 56.45°C 230.38V Efficiency All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 15/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W 20-80W LOAD TESTS 230V Test # 12V 5V 3.3V 5VSB 1.216A 0.497A 0.482A 0.198A DC/AC Efficiency (Watts) 11.975V 5.062V 3.317V 5.060V 26.512 2.487A 0.989A 0.995A 0.396A 40.102 9.8 0.697 80.919% 11.982V 5.059V 3.315V 5.053V 49.558 3.639A 1.484A 1.476A 0.595A 59.548 5.059V 3.314V 5.049V 71.067 4.898A 1.979A 1.990A 0.793A 79.952 9.8 0.797 83.791% 12.131V 652 230.36V 3 654 9.9 230.36V 0.849 4 86.628% 5.045V 653 PF/AC Volts 230.36V 2 3.314V (dB[A]) 0.500 74.223% 5.059V PSU Noise (RPM) 19.678 1 12.116V Fan Speed 657 9.9 92.293 230.37V RIPPLE MEASUREMENTS 230V Test 12V 5V 3.3V 5VSB Pass/Fail 10% Load 5.4 mV 4.9 mV 10.5 mV 6.8 mV Pass 20% Load 10.7 mV 5.5 mV 12.5 mV 6.6 mV Pass 30% Load 8.6 mV 6.1 mV 12.7 mV 6.9 mV Pass 40% Load 8.4 mV 8.3 mV 31.2 mV 24.3 mV Pass 50% Load 9.5 mV 8.1 mV 16.3 mV 8.5 mV Pass 60% Load 9.4 mV 9.2 mV 18.7 mV 9.2 mV Pass 70% Load 10.5 mV 8.5 mV 16.0 mV 8.7 mV Pass 80% Load 10.9 mV 8.7 mV 20.3 mV 8.7 mV Pass 90% Load 11.9 mV 9.6 mV 18.8 mV 9.1 mV Pass 100% Load 19.6 mV 11.1 mV 24.3 mV 17.5 mV Pass 110% Load 19.9 mV 12.3 mV 24.8 mV 18.2 mV Pass Crossload 1 15.7 mV 6.3 mV 19.9 mV 12.9 mV Pass Crossload 2 19.1 mV 10.6 mV 20.7 mV 18.2 mV Pass All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 16/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus EFFICIENCY AND NOISE LEVEL CERTIFICATIONS Anex XPG Core Reactor 850W Top side Power specifications label CERTIFICATIONS 115V Aristeidis Bitziopoulos Lab Director CERTIFICATIONS 230V All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics PAGE 17/17 › The link to the original test results document should be provided in any case www.cybenetics.com [email protected] Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted CYBENETICS LTD Syrou 6, Latsia, 2231, Nicosia Cyprus