Ametek Transducer Comp MTD1 1/9/02 5:10 PM Page 1 Digital & Analog Transducers Power Measurement Catalog Scientific Columbus Power Measurement Catalog SCIENTIFIC COLUMBUS SCIENTIFIC COLUMBUS ■ ROCHESTER INSTRUMENT SYSTEMS Headquarters Rochester Factory AMETEK Precision Instruments-UK Asia Pacific Headquarters 50 Fordham Road Wilmington, Massachusetts 01887 Tel: 978-988-4101 Fax: 978-988-4179 Email: [email protected] 255 North Union Street Rochester, New York 14605 Tel: 585-263-7700 Fax: 585-454-7805 Email: [email protected] 2 Queens Drive Kings Norton Business Centre Birmingham B30 3HH England Tel: +44 121 246 2260 Fax: +44 121 246 2270 Ametek Singapore PTE. LTD. 10 Ang Mo Kio Street 65 #05-12 Techpoint Singapore 569059 (65) 484-2388 x124 (65) 481-6588 W W W. S C I E N T I F I C C O L U M B U S . C O M PUB. NO. 1648 Power Measurement You Can Rely On DPMS Contents Page Digital Power Measurement System 6-9 Digital Power Measurement System Digital Transducer Digital Display Specifications 6 7 8 9 10-29 Watt or Var Combined Watt/Watthour Combined Var/Varhour Volt-Amp Combined Volt-Amp/Volt-Amphour 10-15 16-23 16-23 24-29 24-29 Current or Voltage Harmonics Transducer Accuracy Watt or Var Combined Watt/Var Analog Totalizers Combined Watt/Watthour Combined Var/Varhour Phase Angle (Power Factor) Phase Angle or Voltage Angle Frequency Temperature 31-40 36 41 42-47 48-52 53 54-61 54-61 62-67 68-71 72-75 76-79 99-108 Introduction Current or Voltage Watt or Var Combined Watt/Var 99 100-102 103-105 106-108 Instrumentation 110-125 DC Watt Transducer DC Voltage Isolation Amplifier DC Instrument Amplifier Analog-to-Pulse Converter Registers Calibrator 110-111 112-115 116-117 118-121 122-123 124-125 Reference 126-137 Case Dimensions Glossary Special Options & Abbreviations AC & Calibration Formulas Terms & Conditions 126-127 128-131 132 133 134 Other SCIENTIFIC COLUMBUS Products 30 80 109 Reference JEM10 Meter DM-10 Demand Manager SC-30 Field Standard Instrumentation 31-79 Exceltronic II XLG Transducers (Accuracy to ± 0.2% of Reading) 81 82-88 89 90-91 92-97 98 98 XLG Exceltronic Transducers (Accuracy to ± 0.2% of Reading) Introduction Specifications Enclosure Drawings Ordering Procedure Wiring Diagrams Test Equipment JEM Multifunction Transducer XLP Plug-In Digilogic Transducers (Accuracy to ± 0.1% of Reading) Exceltronic XLP Modular Plug-In Transducers (Accuracy to ± 0.2% of Reading) 81-98 Exceltronic 4-5 1 2-3 Page Digilogic Registration Reply Card Contents Transducer Overview Selecting the Proper Watt or Var Transducer for the Job Contents 1 SCI Transducer Cat. 1-51(MTD) 1 1/9/02, 5:21 PM SCIENTIFIC Meeting Your Accuracy, Output, and Bud COLUMBUS Scientific Columbus offers four dedicated lines of transducers that give you flexibility for meeting your power-measurement needs. get Requirements–Without Compromise. Metal Cans: Seamless, cold-rolled steel cans, primed and painted inside and out, assure the product’s integrity and long life. Technical Support and Applications Assistance 1-800-274-5368 Fast Price Quotations Speak directly to a Scientific Columbus technical specialist who will help you with questions pertaining to installation, mounting, accuracy, or measurement applications. Our Local Sales Representative Will Come to You 1. Digilogic™ Line - These are the most accurate commercially available transducers and are ideal for your most precise measurement applications (accuracy to 0.1% of reading). See pages 10-29. Fast Delivery on Orders from Stock 3. Exceltronic® XLP Modular Plug-In Line - This innovative rack-mount housing allows you to place large numbers of transducers in a limited-space environment (accuracy to 0.2% of reading). See pages 81-98. Scientific Columbus maintains inventory on many popular models for one-day turnaround. Contact your representative or the factory for a list of stocked items. Transducer Functions Available: Current Voltage Phase Angle (Power Factor) Phase Angle Voltage Angle Frequency Temperature Maintenance, Rentals, and Calibration Services Available SCI Transducer Cat. 1-51(MTD) Scientific Columbus maintains a complete maintenance facility and state-of-the-art calibration laboratory traceable to the National Institute of Standards and Technology. For information and a list of services and rental equipment, consult the factory. Easy Installation: Keyhole slots make the unit easy to install and remove in the back of panels or tight corners. Sturdy Construction: Call 1-800-274-5368 for product information on our complete line of modular signal conditioners and alarms. 2 2-3 In addition to our factory fieldservice support, Scientific Columbus sales representatives will come to you to demonstrate products, discuss your application, or provide "handson" application assistance. 2. Exceltronic® Line - These are the most popular utility-grade transducers used in substations, generating plants, and a variety of applications requiring highaccuracy analog outputs (accuracy to 0.2% of reading). See pages 31-79. 4. Exceltronic® II XLG Line - Smaller can size, 4-20 mAdc output, and UL recognition in both U.S. and Canada make this line ideal for utility and process-control applications (accuracy to 0.2% of reading). See pages 99-108. Watt Var Watt/Var Watt/Watthour Var/Varhour Volt-Amp Volt-Amp/VoltAmphour Consult the factory for pricing and delivery estimates. Supported circuit boards with wide electrical traces make the unit durable and electrically strong for harsh environments. 3 1/9/02, 5:21 PM SCIENTIFIC Meeting Your Accuracy, Output, and Bud COLUMBUS Scientific Columbus offers four dedicated lines of transducers that give you flexibility for meeting your power-measurement needs. get Requirements–Without Compromise. Metal Cans: Seamless, cold-rolled steel cans, primed and painted inside and out, assure the product’s integrity and long life. Technical Support and Applications Assistance 1-800-274-5368 Fast Price Quotations Speak directly to a Scientific Columbus technical specialist who will help you with questions pertaining to installation, mounting, accuracy, or measurement applications. Our Local Sales Representative Will Come to You 1. Digilogic™ Line - These are the most accurate commercially available transducers and are ideal for your most precise measurement applications (accuracy to 0.1% of reading). See pages 10-29. Fast Delivery on Orders from Stock 3. Exceltronic® XLP Modular Plug-In Line - This innovative rack-mount housing allows you to place large numbers of transducers in a limited-space environment (accuracy to 0.2% of reading). See pages 81-98. Scientific Columbus maintains inventory on many popular models for one-day turnaround. Contact your representative or the factory for a list of stocked items. Transducer Functions Available: Current Voltage Phase Angle (Power Factor) Phase Angle Voltage Angle Frequency Temperature Maintenance, Rentals, and Calibration Services Available SCI Transducer Cat. 1-51(MTD) Scientific Columbus maintains a complete maintenance facility and state-of-the-art calibration laboratory traceable to the National Institute of Standards and Technology. For information and a list of services and rental equipment, consult the factory. Easy Installation: Keyhole slots make the unit easy to install and remove in the back of panels or tight corners. Sturdy Construction: Call 1-800-274-5368 for product information on our complete line of modular signal conditioners and alarms. 2 2-3 In addition to our factory fieldservice support, Scientific Columbus sales representatives will come to you to demonstrate products, discuss your application, or provide "handson" application assistance. 2. Exceltronic® Line - These are the most popular utility-grade transducers used in substations, generating plants, and a variety of applications requiring highaccuracy analog outputs (accuracy to 0.2% of reading). See pages 31-79. 4. Exceltronic® II XLG Line - Smaller can size, 4-20 mAdc output, and UL recognition in both U.S. and Canada make this line ideal for utility and process-control applications (accuracy to 0.2% of reading). See pages 99-108. Watt Var Watt/Var Watt/Watthour Var/Varhour Volt-Amp Volt-Amp/VoltAmphour Consult the factory for pricing and delivery estimates. Supported circuit boards with wide electrical traces make the unit durable and electrically strong for harsh environments. 3 1/9/02, 5:21 PM Selecting the Proper Watt or Var Transducer for the Job Selecting the Proper Watt or Var Transducer for the Job The Element When selecting a transducer, first determine the number of operating elements required. An element is an electronicmultiplier circuit that accepts voltage and current signals and generates an output signal proportional to the vector product of the two inputs. When one input is proportional to line voltage and the other to line current, the output signal becomes an analog of real power (watts = EI cos(ø)). Transducer Output: Scale Factor A transducer changes energy from one form to another. A watt or var transducer accepts a pair of ac input signals proportional to volts and amps and provides a dc output proportional to ac power (watts or vars). To be usable, the scale factor of this analog output must be specified in one of the following forms: CALIBRATION RANGE FOR STANDARD WATT, VAR, AND COMBINED WATT/VAR Nominal Input Voltage Current 1 Element From To (90% to 180% of Nominal) 11/2 or 2 Element From To 21/2 or 3 Element From To • Secondary Calibration Transducer output is related to the voltage and current inputs applied directly to the transducer input terminals. Standard watt transducers are available with 1, 11/2, 2, 21/2, and 3 elements. Var transducers are identical to watt transducers with one exception: the incoming voltage signal is internally phase-shifted by 90 degrees. Var (volt-amperes reactive) transducer output is an analog signal proportional to vars (vars = EI sin(ø)). • Primary Calibration Transducer output is related directly to the line voltage and currents “out at the load”. This method includes the effects of potential and current transformers between the load and the input to the transducer. 120 V 120 V 120 V 120 V 120 V 120 V 120 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 90 225 450 675 900 1350 2250 180 450 900 1350 1800 2700 4500 180 450 900 1350 1800 2700 4500 360 900 1800 2700 3600 5400 9000 270 675 1350 2025 2700 4050 6750 540 1350 2700 4050 5400 8100 13500 Calibrating Watts (or Vars) The term “calibrating watts (or vars)” is the point used to define the slope of the transducer-output curve. When applied to the transducer, calibrating watts (or vars) cause the rated dc output current to flow. 240 V 240 V 240 V 240 V 240 V 240 V 240 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 180 450 900 1350 1800 2700 4500 360 900 1800 2700 3600 5400 9000 360 900 1800 2700 3600 5400 9000 720 1800 3600 5400 7200 10800 18000 540 1350 2700 4050 5400 8100 13500 1080 2700 5400 8100 10800 16200 27000 Input Watts (or Vars) vs. Transducer Output Scale Factor: 500 W (or Vars)/mAdc 480 V 480 V 480 V 480 V 480 V 480 V 480 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 360 900 1800 2700 3600 5400 9000 720 1800 3600 5400 7200 10800 18000 720 1800 3600 5400 7200 10800 18000 1440 3600 7200 10800 14400 21600 36000 1080 2700 5400 8100 10800 16200 27000 2160 5400 10800 16200 21600 32400 54000 Circuit Configuration 3 phase, 4 wire 3 phase, 4 wire (balanced voltage*) 3 phase, 3 wire 3 phase, 3 wire (balanced voltage & load**) 1 phase, 2 wire Elements Required 3 2 1/2 2 1 1/2 1 * The individual phase-to-phase voltages have the same magnitude and equal phase displacement. ** The individual phase currents have the same magnitude and equal phase displacement. The 1000 W (or vars) value in the previous calculations refers to the effective range of the transducer and is usually twice the calibrating watts (or vars) value. The 150 Vac, 10 A, and 1000 W (or vars) values are maximum values. When calibrating watts (or vars) are applied, the resulting output is the rated output (RO). The watt or var transducer acts as a current generator. The rated output flows provided the load impedance is less than or equal to 10,000 Ω. In other words, the voltage across the output terminals rises to a value necessary to force the proper current flow through the load resistance. The available voltage is guaranteed to be greater than or equal to 10 Vdc, the compliance voltage of the transducer. Output in mAdc Nominal inputs for a watt or var transducer might be 120 Vac, 5 A. For linear operation, however, the input voltage may vary from 0 to 150 Vac and the current from 0 to 10 A. There is a maximum value for the product of the two inputs in addition to a maximum-current and a maximum-voltage value. This limit is twice the calibrating watts (or vars). For example, if the voltage varies up to 150 Vac, then the maximum-allowable current with linearity is 6.66 A (1000 W (or vars)/150 Vac). If the maximum current is 10 A, the maximum-allowable voltage is 100 Vac (1000 W (or vars)/10 A). 2 45 112.5 225 337.5 450 675 1125 90 225 450 675 900 1350 2250 90 225 450 675 900 1350 2250 180 450 900 1350 1800 2700 4500 135 337.5 675 1012.5 1350 2025 3375 270 675 1350 2025 2700 4050 6750 CALIBRATION RANGE FOR P-OPTION WATT, VAR, AND COMBINED WATT/VAR 1 Nominal Input Voltage Current ▼ Transducer Terminology The label on a toaster, power drill, or radio might read, “for use on 120 Vac,” and the actual measured voltage at the wall socket is 114.2 Vac. The device works because the 120 Vac statement is a nominal, or general-case value. Max. Linear Range of Transducer Output 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A ▼ The number of elements required is one less than the number of wires delivering power from the source to the load. 69 V 69 V 69 V 69 V 69 V 69 V 69 V Cal. Watts (or Vars) 0 0 500 W (or Vars) 1000 W (or Vars) Input Watts (or Vars)—1 Element The preceding graph indicates that the transducer has a linear output range of 2 mAdc which equals 1000 W (or vars). The calibrating watts (or vars) are stamped on the unit’s name plate. The standard calibrating watts (or vars) depend on the nominal-input voltage rating, the nominalinput current, and the number of elements. The following tables show calibration ranges for standard or P-Option watt, var, or combined watt/var transducers: 11/2 or 2 Element From To 21/2 or 3 Element From To 69 V 69 V 69 V 69 V 69 V 69 V 69 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 30 75 150 225 300 450 750 90 225 450 675 900 1350 2250 60 150 300 450 600 900 1500 180 450 900 1350 1800 2700 4500 90 225 450 675 900 1350 2250 270 675 1350 2025 2700 4050 6750 120 V 120 V 120 V 120 V 120 V 120 V 120 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 60 150 300 450 600 900 1500 180 450 900 1350 1800 2700 4500 120 300 600 900 1200 1800 3000 360 900 1800 2700 3600 5400 9000 180 450 900 1350 1800 2700 4500 540 1350 2700 4050 5400 8100 13500 240 V 240 V 240 V 240 V 240 V 240 V 240 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 120 300 600 900 1200 1800 3000 360 900 1800 2700 3600 5400 9000 240 600 1200 1800 2400 3600 6000 720 1800 3600 5400 7200 10800 18000 360 900 1800 2700 3600 5400 9000 1080 2700 5400 8100 10800 16200 27000 480 V 480 V 480 V 480 V 480 V 480 V 480 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 240 600 1200 1800 2400 3600 6000 720 1800 3600 5400 7200 10800 18000 480 1200 2400 3600 4800 7200 12000 1440 3600 7200 10800 14400 21600 36000 720 1800 3600 5400 7200 10800 18000 2160 5400 10800 16200 21600 32400 54000 AMETEK® Power Instruments 4 SCI Transducer Cat. 1-51(MTD) 1 Element From To (60% to 180% of Nominal) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 5 4-5 1/9/02, 5:21 PM Selecting the Proper Watt or Var Transducer for the Job Selecting the Proper Watt or Var Transducer for the Job The Element When selecting a transducer, first determine the number of operating elements required. An element is an electronicmultiplier circuit that accepts voltage and current signals and generates an output signal proportional to the vector product of the two inputs. When one input is proportional to line voltage and the other to line current, the output signal becomes an analog of real power (watts = EI cos(ø)). Transducer Output: Scale Factor A transducer changes energy from one form to another. A watt or var transducer accepts a pair of ac input signals proportional to volts and amps and provides a dc output proportional to ac power (watts or vars). To be usable, the scale factor of this analog output must be specified in one of the following forms: CALIBRATION RANGE FOR STANDARD WATT, VAR, AND COMBINED WATT/VAR Nominal Input Voltage Current 1 Element From To 11/2 or 2 Element From To (90% to 180% of Nominal) 21/2 or 3 Element From To • Secondary Calibration Transducer output is related to the voltage and current inputs applied directly to the transducer input terminals. Standard watt transducers are available with 1, 11/2, 2, 21/2, and 3 elements. Var transducers are identical to watt transducers with one exception: the incoming voltage signal is internally phase-shifted by 90 degrees. Var (volt-amperes reactive) transducer output is an analog signal proportional to vars (vars = EI sin(ø)). • Primary Calibration Transducer output is related directly to the line voltage and currents “out at the load”. This method includes the effects of potential and current transformers between the load and the input to the transducer. 120 V 120 V 120 V 120 V 120 V 120 V 120 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 90 225 450 675 900 1350 2250 180 450 900 1350 1800 2700 4500 180 450 900 1350 1800 2700 4500 360 900 1800 2700 3600 5400 9000 270 675 1350 2025 2700 4050 6750 540 1350 2700 4050 5400 8100 13500 Calibrating Watts (or Vars) The term “calibrating watts (or vars)” is the point used to define the slope of the transducer-output curve. When applied to the transducer, calibrating watts (or vars) cause the rated dc output current to flow. 240 V 240 V 240 V 240 V 240 V 240 V 240 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 180 450 900 1350 1800 2700 4500 360 900 1800 2700 3600 5400 9000 360 900 1800 2700 3600 5400 9000 720 1800 3600 5400 7200 10800 18000 540 1350 2700 4050 5400 8100 13500 1080 2700 5400 8100 10800 16200 27000 Input Watts (or Vars) vs. Transducer Output Scale Factor: 500 W (or Vars)/mAdc 480 V 480 V 480 V 480 V 480 V 480 V 480 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 360 900 1800 2700 3600 5400 9000 720 1800 3600 5400 7200 10800 18000 720 1800 3600 5400 7200 10800 18000 1440 3600 7200 10800 14400 21600 36000 1080 2700 5400 8100 10800 16200 27000 2160 5400 10800 16200 21600 32400 54000 Circuit Configuration 3 phase, 4 wire 3 phase, 4 wire (balanced voltage*) 3 phase, 3 wire 3 phase, 3 wire (balanced voltage & load**) 1 phase, 2 wire Elements Required 3 2 1/2 2 1 1/2 1 * The individual phase-to-phase voltages have the same magnitude and equal phase displacement. ** The individual phase currents have the same magnitude and equal phase displacement. The 1000 W (or vars) value in the previous calculations refers to the effective range of the transducer and is usually twice the calibrating watts (or vars) value. The 150 Vac, 10 A, and 1000 W (or vars) values are maximum values. When calibrating watts (or vars) are applied, the resulting output is the rated output (RO). The watt or var transducer acts as a current generator. The rated output flows provided the load impedance is less than or equal to 10,000 Ω. In other words, the voltage across the output terminals rises to a value necessary to force the proper current flow through the load resistance. The available voltage is guaranteed to be greater than or equal to 10 Vdc, the compliance voltage of the transducer. 255 North Union Street 1 90 225 450 675 900 1350 2250 90 225 450 675 900 1350 2250 180 450 900 1350 1800 2700 4500 135 337.5 675 1012.5 1350 2025 3375 270 675 1350 2025 2700 4050 6750 Nominal Input Voltage Current Cal. Watts (or Vars) 0 0 500 W (or Vars) 1000 W (or Vars) Input Watts (or Vars)—1 Element The preceding graph indicates that the transducer has a linear output range of 2 mAdc which equals 1000 W (or vars). The calibrating watts (or vars) are stamped on the unit’s name plate. The standard calibrating watts (or vars) depend on the nominal-input voltage rating, the nominalinput current, and the number of elements. The following tables show calibration ranges for standard or P-Option watt, var, or combined watt/var transducers: Rochester, New York 14605 Phone: 1-800-274-5368 1 Element From To 11/2 or 2 Element From To (60% to 180% of Nominal) 21/2 or 3 Element From To 69 V 69 V 69 V 69 V 69 V 69 V 69 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 30 75 150 225 300 450 750 90 225 450 675 900 1350 2250 60 150 300 450 600 900 1500 180 450 900 1350 1800 2700 4500 90 225 450 675 900 1350 2250 270 675 1350 2025 2700 4050 6750 120 V 120 V 120 V 120 V 120 V 120 V 120 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 60 150 300 450 600 900 1500 180 450 900 1350 1800 2700 4500 120 300 600 900 1200 1800 3000 360 900 1800 2700 3600 5400 9000 180 450 900 1350 1800 2700 4500 540 1350 2700 4050 5400 8100 13500 240 V 240 V 240 V 240 V 240 V 240 V 240 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 120 300 600 900 1200 1800 3000 360 900 1800 2700 3600 5400 9000 240 600 1200 1800 2400 3600 6000 720 1800 3600 5400 7200 10800 18000 360 900 1800 2700 3600 5400 9000 1080 2700 5400 8100 10800 16200 27000 480 V 480 V 480 V 480 V 480 V 480 V 480 V 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A 240 600 1200 1800 2400 3600 6000 720 1800 3600 5400 7200 10800 18000 480 1200 2400 3600 4800 7200 12000 1440 3600 7200 10800 14400 21600 36000 720 1800 3600 5400 7200 10800 18000 2160 5400 10800 16200 21600 32400 54000 Fax: 585-454-7805 4 SCI Transducer Cat. 1-51(MTD) 45 112.5 225 337.5 450 675 1125 CALIBRATION RANGE FOR P-OPTION WATT, VAR, AND COMBINED WATT/VAR ▼ Nominal inputs for a watt or var transducer might be 120 Vac, 5 A. For linear operation, however, the input voltage may vary from 0 to 150 Vac and the current from 0 to 10 A. There is a maximum value for the product of the two inputs in addition to a maximum-current and a maximum-voltage value. This limit is twice the calibrating watts (or vars). For example, if the voltage varies up to 150 Vac, then the maximum-allowable current with linearity is 6.66 A (1000 W (or vars)/150 Vac). If the maximum current is 10 A, the maximum-allowable voltage is 100 Vac (1000 W (or vars)/10 A). Output in mAdc 2 Transducer Terminology The label on a toaster, power drill, or radio might read, “for use on 120 Vac,” and the actual measured voltage at the wall socket is 114.2 Vac. The device works because the 120 Vac statement is a nominal, or general-case value. AMETEK® Power Instruments Max. Linear Range of Transducer Output 0–1 A 0–2.5 A 0–5 A 0–7.5 A 0–10 A 0–15 A 0–25 A ▼ The number of elements required is one less than the number of wires delivering power from the source to the load. 69 V 69 V 69 V 69 V 69 V 69 V 69 V 5 4-5 1/9/02, 5:21 PM One Enclosure! 37 Measurements! Configure the DPMS to the exact measurment that you need. SCIENTIFIC Digital Transducer COLUMBUS DPMS Digital Power Measurement System With traditional transducers, one transducer is required for each measurement that you need. With the DPMS, one transducer can make multiple measurements. In fact, you can take up to 37 measurements simultaneously with just one DPMS unit! This means you can often specify one DPMS instead of multiple transducers. With direct communications capability, think of the savings that can be achieved in every aspect of a new project. Not only is it easier for Engineering, the DPMS will also save on wiring and valuable panel space. The DPMS can be configured to the exact measurement you need. Configuration is done easily with the included PC configuration software, or you can request that your DPMS come pre-configured from the factory. With optional voltage ranges, there is virtually no transducer application that a DPMS can’t fill. Fully Programmable Digital & Analog Transducer with Built-in Communications DPMS SCIENTIFIC Digital Power Measurement System COLUMBUS Fully Programmable Digital & Analog Transducer with Built-in Communications The DPMS makes an excellent back up strategy. Rather than stocking numerous types and quantities of back-up transducers, you can now stock far fewer DPMS units, which can be quickly and easily configured to your replacement needs. One of the most exciting innovations of the DPMS is its communication capabilities. With MODBUS and DNP as standard protocols, connections have never been simpler. The RS-485 port allows the transducer to communicate directly to your equipment through a multi-drop configuration, saving you valuable input ports and the need for multiplexors. All this and also a separate port to use with the DPMS-D external display. It gets even better! The DPMS also supports TLC. In those applications where accuracy is important, but it may not be practical to install equipment at the point you wish to actually measure, use TLC to correct for inaccuracies brought on by transformer and line losses. SCIENTIFIC COLUMBUS DPMS Digital Power Measurement System CHECK THE SPECS! You will find the DPMS to be highly accurate, durable, flexible, and economical. The future of transducers has arrived, and it’s the DPMS – Digital Programmable Measurement System from Rochester Instrument Systems, the world leader in transducer technology! AMETEK® Power Instruments 6 SCI Transducer Cat. 1-51(MTD) 255 North Union Street Rochester, New York 14605 The DPMS ships with configuration software to get you up and running quickly. Easily change transducer settings and outputs with DPMSTalk configuration software. Phone: 1-800-274-5368 Fax: 585-454-7805 7 6-7 1/9/02, 5:22 PM One Enclosure! 37 Measurements! SCIENTIFIC Digital Transducer COLUMBUS DPMS SCIENTIFIC Digital Power Measurement System COLUMBUS DPMS Configure the DPMS to the exact measurment that you need. Digital Power Measurement System With traditional transducers, one transducer is required for each measurement that you need. With the DPMS, one transducer can make multiple measurements. In fact, you can take up to 37 measurements simultaneously with just one DPMS unit! This means you can often specify one DPMS instead of multiple transducers. With direct communications capability, think of the savings that can be achieved in every aspect of a new project. Not only is it easier for Engineering, the DPMS will also save on wiring and valuable panel space. The DPMS can be configured to the exact measurement you need. Configuration is done easily with the included PC configuration software, or you can request that your DPMS come pre-configured from the factory. With optional voltage ranges, there is virtually no transducer application that a DPMS can’t fill. Fully Programmable Digital & Analog Transducer with Built-in Communications Fully Programmable Digital & Analog Transducer with Built-in Communications The DPMS makes an excellent back up strategy. Rather than stocking numerous types and quantities of back-up transducers, you can now stock far fewer DPMS units, which can be quickly and easily configured to your replacement needs. One of the most exciting innovations of the DPMS is its communication capabilities. With MODBUS and DNP as standard protocols, connections have never been simpler. The RS-485 port allows the transducer to communicate directly to your equipment through a multi-drop configuration, saving you valuable input ports and the need for multiplexors. All this and also a separate port to use with the DPMS-D external display. It gets even better! The DPMS also supports TLC. In those applications where accuracy is important, but it may not be practical to install equipment at the point you wish to actually measure, use TLC to correct for inaccuracies brought on by transformer and line losses. SCIENTIFIC COLUMBUS DPMS CHECK THE SPECS! You will find the DPMS to be highly accurate, durable, flexible, and economical. The future of transducers has arrived, and it’s the DPMS – Digital Programmable Measurement System from Rochester Instrument Systems, the world leader in transducer technology! Digital Power Measurement System AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Easily change transducer settings and outputs with DPMSTalk configuration software. Fax: 585-454-7805 6 SCI Transducer Cat. 1-51(MTD) The DPMS ships with configuration software to get you up and running quickly. 7 6-7 1/9/02, 5:22 PM Communicate with 15 DPMS Units! DPMS-D Optional Digital Display Display 4 line x 20 character vacuum fluorescent display allows Unit ID and 3 simultaneous measurements to be viewed Character height 0.19 inch Color-blue 3 key switches allow selection of data to be viewed 12 standard display screens and 4 custom display screens Displays in primary units (CT&PT ratios configured in DPMS) Quantities available for display Watts – per phase and total Vars – per phase and total Watthours – delivered and received Varhours – delivered and received Voltage – phase to neutral and phase to phase Current – phase and neutral (calculated) Volt Amps – per phase and total Power Factor – per phase and system frequency Distortion – total harmonic distortion of each voltage and current Watthours – bidirectional Varhours – bidirectional Communications Multi Addressing allows communication to up to 15 DPMS units per DPMS-D display module Half duplex RS-485 Recommended maximum distance between DPMS and DPMS-D is 4000 feet Fully Programmable Digital & Analog Transducer with Built-in Communications • Multi-Function Transducer is perfect solution for many varied applications • Configured by User (or factory as needed) • Programmable as 2, 2.5 or 3 elements • Configurable Analog Outputs and Digital Contact & Alarm Outputs • Excellent for replacement strategy: One unit replaces many makes and models • Highly Accurate • Excellent for back-up strategy: One unit on shelf backs up many varied units in the field. • Programmable Communications of MODBUS and DNP 3.0 • Economical • Remote Display Option available • Space Saving Size 3.75" x 5.375" x 6.5" • Transformer Loss Compensation (TLC) DIGITAL POWER MEASUREMENT SYSTEM Programmable Configuration 2 element for 3 phase 3 wire delta 2 1/2 element for 3 phase 4 wire wye 3 element for 3 phase 4 wire wye Additional Options: Nominal voltage input: P2 = 277V P3 = 480V P4 = 69V. Analog output option: A1 = 0-1mA A2 = 4-20mA. Power Requirements 95 to 256 VAC @ 50/60 Hz or DC Digital output option: D1 = Contact outputs. Mechanical Panel cutout 4.38 x 3.75 inches Weight 1.4 lbs. (0.64 kg.) Programming Kit: Environmental Operating Temperature range: -20° to +70°C Storage Temperature: -40° to +85°C Humidity: 20 to 90% RH non condensing RFI: no effect when subjected to 10 V/M @ 1 meter ESD: IEC 801-2 level 3 (8 kV) with no damage Surge Withstand: ANSI/IEEE C37.90, IEC 801-4 Class 4 Isolation: 2500 VAC RMS from power to Case or Communications port1 Fill in the order codes as shown below to create model number: Inputs Current Nominal – 5 amps Operating Range – 0 to 10 amps Burden per Element = 0.25 VA Voltage Nominal – 120 volts Operating Range – 85 to 150 volts Optional: 69 VAC Nominal, Range 50-85 277 VAC Nominal, Range 180320 VAC 480 VAC Nominal, Range 310-550 VAC Burden per Element: 0.05 VA Frequency 45 to 65 Hertz Sample Rate 128 Samples/Cycle Power Supply 95 to 265 VAC @ 50/60 Hz or DC 6 VA Maximum @ 120 V Outputs 3 Channel Analog: All (3) channels are independently configured and scaled with DPMSTalk software Option A1: 0 to ± 1 ma, maximum 10 volt compliance Option A2: 4 to 20 ma, maximum 12 volt compliance Response Time </= 200 mS 6 Channel Digital – Option D1: All (6) channels are independently configured and scaled with DPMSTalk software as KYZ contacts for energy measurements or as high/low threshold alarms. Solid state rated 50 ma @135 VAC/VDC with less than 5 volt drop 54,000 CPH maximum Environment Operating Temperature range: -20° to +70°C Storage Temperature: -40° to +85°C Humidity: 20 to 90% RH non condensing RFI: <1% when subjected to 10 V/M @ 1 meter ESD: IEC 801-2 level 3 (8 kV) with no damage Surge Withstand: ANSI/IEEE C37.90, IEC 801-4 Class 4 Isolation: 2500 VAC RMS from Input/Output/Power/Case 500 VAC RMS between digital outputs Communication/Configuration ports share common with the analog outputs Influences Affecting Accuracy Temperature: Conversion only: 75 ppm/°C Including analog outputs: 125 ppm/°C Long Term Stability: 0.1% of rated output/year, noncumulative Humidity: less than 0.05% of rated output over the operating range Mechanical Size: 3.75" x 5.375" x 6.5" Weight: 2.6 lbs. (1.2 kg.) Communications Hardware Protocol: RS-232 (full duplex) or RS-485 (half duplex) Programmable Software Protocol Modbus: RTU or ASCII Mode DNP 3.0 A portion of this product was funded by the New York State Energy Research and Development Authority (NYSERDA) R0 = Without Programming kit consisting of DPMSTalk Configuration Software and RS-232/485 adapter cable Example: DPMS-P3-A1-D1 is a DPMS at 480V with 1mA analog outputs, digital contact outputs, and with RS-232/485 adapter cable and DPMSTalk configuration software. Visit Us Online! WWW.ROCHESTER.COM AMETEK® Power Instruments 8 SCI Transducer Cat. 1-51(MTD) Measurement/Calculation Accuracy Volts, Amps, Watts, Vars: 0.2% Watthours, Varhours: 0.2% Neutral current: 0.75% Volt Amps: 0.5% Power Factor: ±0.008* (rated VA/input VA) Analog output: ±0.1% Measured and/or calculated quantities Watts – per phase and total Vars – per phase and total Voltage – phase to neutral and phase to phase Current – phase and neutral (calculated) Volt Amps – per phase and total Frequency Distortion – Total Harmonic Distortion of each voltage & current Watthours – delivered and received Varhours – delivered and received Power Factor – per phase and system DPMS Order Configuration Sheet A base DPMS is standard equipped with: a nominal potential of 120V, nominal current of 5 Amps, no analog outputs, no digital outputs, and communications kit for programming the DPMS. The communications kit is standard and includes DPMSTalk programming software and a RS-232/485 adapter with cable. DPMS Specifications Digital Display 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 9 8-9 1/9/02, 5:22 PM Communicate with 15 DPMS Units! Fully Programmable Digital & Analog Transducer with Built-in Communications DPMS-D Optional Digital Display Display 4 line x 20 character vacuum fluorescent display allows Unit ID and 3 simultaneous measurements to be viewed Character height 0.19 inch Color-blue 3 key switches allow selection of data to be viewed 12 standard display screens and 4 custom display screens Displays in primary units (CT&PT ratios configured in DPMS) Quantities available for display Watts – per phase and total Vars – per phase and total Watthours – delivered and received Varhours – delivered and received Voltage – phase to neutral and phase to phase Current – phase and neutral (calculated) Volt Amps – per phase and total Power Factor – per phase and system frequency Distortion – total harmonic distortion of each voltage and current Watthours – bidirectional Varhours – bidirectional Communications Multi Addressing allows communication to up to 15 DPMS units per DPMS-D display module Half duplex RS-485 Recommended maximum distance between DPMS and DPMS-D is 4000 feet • Multi-Function Transducer is perfect solution for many varied applications • Configured by User (or factory as needed) • Programmable as 2, 2.5 or 3 elements • Configurable Analog Outputs and Digital Contact & Alarm Outputs • Excellent for replacement strategy: One unit replaces many makes and models • Highly Accurate • Excellent for back-up strategy: One unit on shelf backs up many varied units in the field. • Programmable Communications of MODBUS and DNP 3.0 • Economical • Remote Display Option available • Space Saving Size 3.75" x 5.375" x 6.5" • Transformer Loss Compensation (TLC) Additional Options: Nominal voltage input: P2 = 277V P3 = 480V P4 = 69V. Analog output option: A1 = 0-1mA A2 = 4-20mA. Power Requirements 95 to 256 VAC @ 50/60 Hz or DC Digital output option: D1 = Contact outputs. Mechanical Panel cutout 4.38 x 3.75 inches Weight 1.4 lbs. (0.64 kg.) Programming Kit: Environmental Operating Temperature range: -20° to +70°C Storage Temperature: -40° to +85°C Humidity: 20 to 90% RH non condensing RFI: no effect when subjected to 10 V/M @ 1 meter ESD: IEC 801-2 level 3 (8 kV) with no damage Surge Withstand: ANSI/IEEE C37.90, IEC 801-4 Class 4 Isolation: 2500 VAC RMS from power to Case or Communications port1 Fill in the order codes as shown below to create model number: AMETEK® Power Instruments 255 North Union Street DIGITAL POWER MEASUREMENT SYSTEM Programmable Configuration 2 element for 3 phase 3 wire delta 2 1/2 element for 3 phase 4 wire wye 3 element for 3 phase 4 wire wye Measured and/or calculated quantities Watts – per phase and total Vars – per phase and total Voltage – phase to neutral and phase to phase Current – phase and neutral (calculated) Volt Amps – per phase and total Frequency Distortion – Total Harmonic Distortion of each voltage & current Watthours – delivered and received Varhours – delivered and received Power Factor – per phase and system Inputs Current Nominal – 5 amps Operating Range – 0 to 10 amps Burden per Element = 0.25 VA Voltage Nominal – 120 volts Operating Range – 85 to 150 volts Optional: 69 VAC Nominal, Range 50-85 277 VAC Nominal, Range 180320 VAC 480 VAC Nominal, Range 310-550 VAC Burden per Element: 0.05 VA Frequency 45 to 65 Hertz Sample Rate 128 Samples/Cycle Power Supply 95 to 265 VAC @ 50/60 Hz or DC 6 VA Maximum @ 120 V DPMS Order Configuration Sheet A base DPMS is standard equipped with: a nominal potential of 120V, nominal current of 5 Amps, no analog outputs, no digital outputs, and communications kit for programming the DPMS. The communications kit is standard and includes DPMSTalk programming software and a RS-232/485 adapter with cable. Outputs 3 Channel Analog: All (3) channels are independently configured and scaled with DPMSTalk software Option A1: 0 to ± 1 ma, maximum 10 volt compliance Option A2: 4 to 20 ma, maximum 12 volt compliance Response Time </= 200 mS 6 Channel Digital – Option D1: All (6) channels are independently configured and scaled with DPMSTalk software as KYZ contacts for energy measurements or as high/low threshold alarms. Solid state rated 50 ma @135 VAC/VDC with less than 5 volt drop 54,000 CPH maximum Measurement/Calculation Accuracy Volts, Amps, Watts, Vars: 0.2% Watthours, Varhours: 0.2% Neutral current: 0.75% Volt Amps: 0.5% Power Factor: ±0.008* (rated VA/input VA) Analog output: ±0.1% Environment Operating Temperature range: -20° to +70°C Storage Temperature: -40° to +85°C Humidity: 20 to 90% RH non condensing RFI: <1% when subjected to 10 V/M @ 1 meter ESD: IEC 801-2 level 3 (8 kV) with no damage Surge Withstand: ANSI/IEEE C37.90, IEC 801-4 Class 4 Isolation: 2500 VAC RMS from Input/Output/Power/Case 500 VAC RMS between digital outputs Communication/Configuration ports share common with the analog outputs Influences Affecting Accuracy Temperature: Conversion only: 75 ppm/°C Including analog outputs: 125 ppm/°C Long Term Stability: 0.1% of rated output/year, noncumulative Humidity: less than 0.05% of rated output over the operating range Mechanical Size: 3.75" x 5.375" x 6.5" Weight: 2.6 lbs. (1.2 kg.) Communications Hardware Protocol: RS-232 (full duplex) or RS-485 (half duplex) Programmable Software Protocol Modbus: RTU or ASCII Mode DNP 3.0 A portion of this product was funded by the New York State Energy Research and Development Authority (NYSERDA) R0 = Without Programming kit consisting of DPMSTalk Configuration Software and RS-232/485 adapter cable Example: DPMS-P3-A1-D1 is a DPMS at 480V with 1mA analog outputs, digital contact outputs, and with RS-232/485 adapter cable and DPMSTalk configuration software. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 8 SCI Transducer Cat. 1-51(MTD) DPMS Specifications Digital Display 9 8-9 1/9/02, 5:22 PM SCIENTIFIC Digilogic AC Watt or Var Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS DIGILOGIC AC WATT OR VAR TRANSDUCERS Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Applications u Accuracy to 0.1% of reading u Utility billing Outputs u 0 to ±1 mAdc u Exceptional reliability u Test laboratories u 1–5 or 1–3–5 mAdc u Excellent long-term stability u State estimation u 4–20 or 4–12–20 mAdc u No zero adjustment required u 10–50 or 10–30–50 mAdc 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* Temperature Effect on Accuracy ± 0.005% / ° C ±0.0065% / ° C ±0.009% / ° C ±0.01% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc 0–10,000 Ω Output Ripple Peak < 0.5% RO < 0.25% RO < 400 ms to 99% < 1 Second to 99% Response Time Power Factor < 0.5% RO < 0.25% RO < 400 ms to 99% < 1 Second to 99% ±0.04% VA (maximum) (Included in Accuracy specification above.) Gain Zero ± 1% of Reading (minimum) ±10% of Span (minimum) None Required ±5% of Zero Point (minimum) Frequency Range ± 1% of Reading (minimum) ±10% of Span (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz ±0.05% RO, Noncumulative Operating Humidity 60 Hz ± 0.1% of Span, Noncumulative ± 0.1% RO, Noncumulative Complete (Input/Output/Power/Case) Dielectric Withstand 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight Approximate Dimensions (excluding mounting plate) Overrange with Linearity ±0.2% of Span, Noncumulative 0–95% Noncondensing Isolation The Digilogic Transducer’s measurement accuracy allows precise measurement of the difference between terminal power and GSU high-side power. This difference, characterized as a station loss, is measurable because the random errors associated with this type of measurement are negligible when using high-accuracy Digilogic Transducers. See Table 2 on page 8. 0–10,000 Ω Any Stability (per year) As in any system, generation losses represent unrecovered expense. Within the generating station, losses between the generator terminals and the highvoltage side of the generator step-up (GSU) transformer can be significant. These losses, which result from the high currents and large voltage change through the GSU, can affect the precision of the control room real and reactive power and energy measurements. 10 Vdc See Table 2 on page 8. Load Standard Calibration Adjustments The exceptional accuracy of the Digilogic Transducer line allows for uncommon measurements that have real payback. P-Option* Vars (Var Transducer) 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A PF Effect on Accuracy Measure Power Plant Losses with Digilogic Watt or Var Transducers 0 to ±1 mAdc Vars (Var Transducer) P-Option* Watts (Watt Transducer) ±(0.09% Reading + 0.005% RO) ±(0.1% Reading + 0.05% RO) ±(0.15% Reading + 0.01% RO) ±(0.15% Reading + 0.05% RO) at 0–200% RO at 0–120% RO at 0–200% RO at 0–120% RO Accuracy Features 0 to ±1 mAdc Watts (Watt Transducer) Digilogic Digilogic watt and var transducers provide utility, laboratory, and industrial users with the highest degree of accuracy for applications requiring precision measurement of real and reactive electrical power. A precision electronic multiplier allows measurement of true power to within 0.1% of reading throughout a wide range of input voltage, current, power factor, and environmental conditions. 4 lbs., 6 oz. (2 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 4 lbs., 12 oz. (2.2 kg) 500–600 Watts/Element 4 lbs., 14 oz. (2.2 kg) 4 lbs., 8 oz. (2 kg) 7.2" W x 5.3" D x 5.8" H 7.0" W x 3.7" D x 5.6" H (183 mm x 135 mm x 147 mm) (178 mm x 94 mm x 142 mm) Style V Case, see page 123 Style I Case, see page 122 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. Specifications subject to change without notice. Knowing generation losses assists in the optimal scheduling of generation resources. Using Digilogic Transducers assures accurate and reliable loss measurement. AMETEK® Power Instruments 10 SCI Transducer Cat. 1-51(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 11 10-11 1/9/02, 5:22 PM SCIENTIFIC Digilogic AC Watt or Var Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS DIGILOGIC AC WATT OR VAR TRANSDUCERS Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Applications u Accuracy to 0.1% of reading u Utility billing Outputs u 0 to ±1 mAdc u Test laboratories u 1–5 or 1–3–5 mAdc u Excellent long-term stability u State estimation u 4–20 or 4–12–20 mAdc u No zero adjustment required u 10–50 or 10–30–50 mAdc 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ± 0.005% / ° C ±0.0065% / ° C ±0.009% / ° C ±0.01% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc 0–10,000 Ω Output Ripple Peak < 0.5% RO < 0.25% RO < 400 ms to 99% < 1 Second to 99% Response Time Power Factor Standard Calibration Adjustments The Digilogic Transducer’s measurement accuracy allows precise measurement of the difference between terminal power and GSU high-side power. This difference, characterized as a station loss, is measurable because the random errors associated with this type of measurement are negligible when using high-accuracy Digilogic Transducers. < 0.5% RO < 0.25% RO < 400 ms to 99% < 1 Second to 99% ±0.04% VA (maximum) (Included in Accuracy specification above.) Gain Zero ± 1% of Reading (minimum) ±10% of Span (minimum) None Required ±5% of Zero Point (minimum) Frequency Range ± 1% of Reading (minimum) ±10% of Span (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz ±0.05% RO, Noncumulative Operating Humidity 60 Hz ± 0.1% of Span, Noncumulative ± 0.1% RO, Noncumulative Complete (Input/Output/Power/Case) Dielectric Withstand 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight Approximate Dimensions (excluding mounting plate) Overrange with Linearity ±0.2% of Span, Noncumulative 0–95% Noncondensing Isolation As in any system, generation losses represent unrecovered expense. Within the generating station, losses between the generator terminals and the highvoltage side of the generator step-up (GSU) transformer can be significant. These losses, which result from the high currents and large voltage change through the GSU, can affect the precision of the control room real and reactive power and energy measurements. See Table 2 on page 8. 0–10,000 Ω Any Stability (per year) The exceptional accuracy of the Digilogic Transducer line allows for uncommon measurements that have real payback. 10 Vdc See Table 2 on page 8. Load PF Effect on Accuracy Measure Power Plant Losses with Digilogic Watt or Var Transducers P-Option* Vars (Var Transducer) Temperature Effect on Accuracy Compliance Voltage u Exceptional reliability 0 to ±1 mAdc Vars (Var Transducer) P-Option* Watts (Watt Transducer) ±(0.09% Reading + 0.005% RO) ±(0.1% Reading + 0.05% RO) ±(0.15% Reading + 0.01% RO) ±(0.15% Reading + 0.05% RO) at 0–200% RO at 0–120% RO at 0–200% RO at 0–120% RO Accuracy Features 0 to ±1 mAdc Watts (Watt Transducer) Digilogic Digilogic watt and var transducers provide utility, laboratory, and industrial users with the highest degree of accuracy for applications requiring precision measurement of real and reactive electrical power. A precision electronic multiplier allows measurement of true power to within 0.1% of reading throughout a wide range of input voltage, current, power factor, and environmental conditions. 4 lbs., 6 oz. (2 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 4 lbs., 12 oz. (2.2 kg) 4 lbs., 8 oz. (2 kg) 7.2" W x 5.3" D x 5.8" H 7.0" W x 3.7" D x 5.6" H (183 mm x 135 mm x 147 mm) (178 mm x 94 mm x 142 mm) Style V Case, see page 123 Style I Case, see page 122 500–600 Watts/Element 500–1000 Vars/Element 4 lbs., 14 oz. (2.2 kg) 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. Specifications subject to change without notice. Knowing generation losses assists in the optimal scheduling of generation resources. Using Digilogic Transducers assures accurate and reliable loss measurement. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 10 SCI Transducer Cat. 1-51(MTD) 11 10-11 1/9/02, 5:22 PM Ordering Procedure Digilogic AC Watt or Var Transducers Ordering Procedure Digilogic AC Watt or Var Transducers Table 3 Auxiliary Power Supply Selection ORDERING PROCEDURE Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Output Auxiliary Power Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 External Aux. Power Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 6 Table 6 Table 3 A2 DL342K5 -5 PAN7 -1 -RS Specify output voltage A4 -SM (P-Option Units) A2** (leave blank) Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Connection Single Phase 3 Phase, 3 Wire 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars 3 VA 3 VA External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 84-108% of Nominal Aux. Power Voltage 50-500 Hz Equals Input Frequency 6 VA 6 VA Current Option -3 -4 Std.*** -11 -5 15 A -8**** Current Range Calibration at Rated Output Nominal w/ Accuracy (5 A Nominal Input) 1A 0-2 A 100 W or Vars/Element 2.5 A 0-5 A 250 W or Vars/Element 5A 0-10 A 500 W or Vars/Element 7.5 A 0-15 A 750 W or Vars/Element 10 A 0-20 A 1000 W or Vars/Element 0-20 A1500 W or Vars/Element 25 A 0-30 A 2500 W or Vars/Element Option -0 Std.*** -1 -9 -2 Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element -7 *** Leave "Input" positions blank in the model number. **** Option -8 requires a Style V case. (See page 123 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) Table 5 Scaling Resistor (-RS)/Frequency Options Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor † You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 6 Other Options Option -SC†† -SM P-Option PAN6 PAN7 PAN8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc PAN6-B PAN7-B PAN8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc -Z Description Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option unidirectional units) †† You must specify the desired input value: 0 to ±1 mAdc units can be calibrated within 90-180% of their standardcalibration input watts or vars. (Example: A 2-element watt transducer is calibrated to 1000 W standard. The -SC option can be added for input levels from 900 W (90%) to 1800 W (180%).) P-Option units can be calibrated within 60-180% of their standard-calibration input watts or vars. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. AMETEK® Power Instruments 12 SCI Transducer Cat. 1-51(MTD) Voltage * 11/2- and 21/2-element units require a balanced voltage. Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. 50-500 Hz Equals Input Frequency Table 4 Input Selection Option -RS† -6 -12 -6-RS† -12-RS† Table 1 Base Model Number Selection Var Model No. DLV5C5 DLV5C511/2 DLV31K5 DLV31K521/2 DLV342K5 85-135 Vac 70-112% of Nominal Aux. Power Voltage DC external auxiliary power available; see Special Options on page 128. DL342K5A2-5-1-RS-SM-SC 3-element, 0 to ±1 mAdc Watt Transducer; 120 Vac external auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Watt Model No. DL5C5 DL5C511/2 DL31K5 DL31K521/2 DL342K5 Burden External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) -SC DL342K5PAN7A4-5-1-RS-SM-SC 3-element, 4-20 mAdc Watt Transducer; internal auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Element 1 11/2* 2 21/2* 3 Frequency Range ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. EXAMPLES: A2** A4 A4 0 to ±1 mAdc output Input Range Digilogic Base Model No. P-Option outputs Description (0 to ±1 mAdc Units) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 13 12-13 1/9/02, 5:22 PM Ordering Procedure Digilogic AC Watt or Var Transducers Ordering Procedure Digilogic AC Watt or Var Transducers Table 3 Auxiliary Power Supply Selection ORDERING PROCEDURE Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Output Auxiliary Power Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 External Aux. Power Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 6 Table 6 Table 3 A2 -5 PAN7 -1 -RS Specify output voltage A4 -SM (P-Option Units) A2** (leave blank) Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. DL342K5PAN7A4-5-1-RS-SM-SC 3-element, 4-20 mAdc Watt Transducer; internal auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Connection Single Phase 3 Phase, 3 Wire 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars AMETEK® Power Instruments External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 84-108% of Nominal Aux. Power Voltage 50-500 Hz Equals Input Frequency 6 VA 6 VA Current Option -3 -4 Std.*** -11 -5 15 A -8**** Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc PAN6-B PAN7-B PAN8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc Phone: 1-800-274-5368 Option -0 Std.*** -1 -9 -2 Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element -7 *** Leave "Input" positions blank in the model number. Table 5 Scaling Resistor (-RS)/Frequency Options Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor † You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 6 Other Options P-Option PAN6 PAN7 PAN8 Rochester, New York 14605 Voltage **** Option -8 requires a Style V case. (See page 123 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) Option -SC†† -SM 255 North Union Street Current Range Calibration at Rated Output Nominal w/ Accuracy (5 A Nominal Input) 1A 0-2 A 100 W or Vars/Element 2.5 A 0-5 A 250 W or Vars/Element 5A 0-10 A 500 W or Vars/Element 7.5 A 0-15 A 750 W or Vars/Element 10 A 0-20 A 1000 W or Vars/Element 0-20 A1500 W or Vars/Element 25 A 0-30 A 2500 W or Vars/Element -Z Description Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option unidirectional units) †† You must specify the desired input value: 0 to ±1 mAdc units can be calibrated within 90-180% of their standardcalibration input watts or vars. (Example: A 2-element watt transducer is calibrated to 1000 W standard. The -SC option can be added for input levels from 900 W (90%) to 1800 W (180%).) P-Option units can be calibrated within 60-180% of their standard-calibration input watts or vars. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. Fax: 585-454-7805 12 SCI Transducer Cat. 1-51(MTD) 3 VA 3 VA * 11/2- and 21/2-element units require a balanced voltage. Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. 50-500 Hz Equals Input Frequency Table 4 Input Selection Option -RS† -6 -12 -6-RS† -12-RS† Table 1 Base Model Number Selection Var Model No. DLV5C5 DLV5C511/2 DLV31K5 DLV31K521/2 DLV342K5 85-135 Vac 70-112% of Nominal Aux. Power Voltage DC external auxiliary power available; see Special Options on page 128. DL342K5A2-5-1-RS-SM-SC 3-element, 0 to ±1 mAdc Watt Transducer; 120 Vac external auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Watt Model No. DL5C5 DL5C511/2 DL31K5 DL31K521/2 DL342K5 Burden External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) -SC If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. Element 1 11/2* 2 21/2* 3 Frequency Range ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) DL342K5 EXAMPLES: A2** A4 A4 0 to ±1 mAdc output Input Range Digilogic Base Model No. P-Option outputs Description (0 to ±1 mAdc Units) 13 12-13 1/9/02, 5:22 PM Wiring Diagrams Digilogic AC Watt or Var Transducers Wiring Diagrams Digilogic AC Watt or Var Transducers WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) 1 Element, Single Phase, 2 Wire 1 Element, Single Phase, 2 Wire 11/2 Element, Single Phase, 3 Wire L1 LINE L1 - DC OUTPUT 1 7 L1 L2 - + 2 3 8 9 4 10 5 11 6 12 DC OUTPUT 1 6A 7 12A LINE N 11/2 Element, Single Phase, 3 Wire LINE L1 L2 LINE N Digilogic WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) L2 L2 - DC OUTPUT - + DC OUTPUT + + 2 3 8 9 4 10 5 11 6 12 6A 1 2 3 4 5 6 6A 7 8 9 10 11 12 12A 1 2 3 4 5 6 6A 7 8 9 10 11 12 12A 12A LOAD LOAD EXTERNAL AUX. POWER EXTERNAL AUX. POWER 11/2 Element, 3 Phase, 3 Wire, Delta L1 - DC OUTPUT 1 7 L3 L1 + 2 3 8 9 4 10 5 11 6 12 11/2 Element, 3 Phase, 3 Wire, Delta 2 Element, 3 Phase, 3 Wire, Delta LINE L2 6A DC OUTPUT 1 12A 7 LINE L2 L1 + 2 3 8 9 4 10 5 11 6 12 DC OUTPUT - DC OUTPUT 1 2 3 4 5 6 6A 1 2 3 4 5 6 6A 7 8 9 10 11 12 12A 7 8 9 10 11 12 12A L2 L3 EXTERNAL AUX. POWER LOAD 21/2 Element, 3 Phase, 4 Wire, Wye LINE L1 N L2 LOAD 3 Element, 3 Phase, 4 Wire, Wye LINE L1 N - 1 - + 2 3 4 5 6 DC OUTPUT 1 6A 2 DC OUTPUT L3 N LINE 3 4 5 6 9 10 11 12 - 2 3 4 5 6 6A EXTERNAL AUX. POWER 12A 7 8 DC OUTPUT 9 10 11 12 1 2 3 4 5 6 6A EXTERNAL AUX. POWER 12A LOAD 8 9 10 11 12 12A 7 8 9 10 11 12 12A LOAD LOAD LOAD A2 Models: Shown. A4 Models: External aux. power not required. Adjust AMETEK® Power Instruments 14 SCI Transducer Cat. 1-51(MTD) A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 J 1001-9111 (10K) 14-15 N + EXTERNAL AUX. POWER 7 Adjust L3 6A EXTERNAL AUX. POWER 8 + L2 + 1 7 L3 + L1 DC OUTPUT LINE L2 LOAD 3 Element, 3 Phase, 4 Wire, Wye L3 L1 L3 12A LINE L2 2 Element, 3 Phase, 3 Wire, Delta LINE L2 + EXTERNAL AUX. POWER L1 LOAD 6A EXTERNAL AUX. POWER 21/2 Element, 3 Phase, 4 Wire, Wye EXTERNAL AUX. POWER L3 - LOAD EXTERNAL AUX. POWER NOTE: For units with -8 option, connect current input to terminals 7 (•) & 10. LOAD EXTERNAL AUX. POWER NOTE: For units with -8 option, connect current input to terminals 7 (•) & 10. 1/9/02, 5:23 PM Fax: 585-454-7805 15 Wiring Diagrams Digilogic AC Watt or Var Transducers Wiring Diagrams Digilogic AC Watt or Var Transducers WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) 1 Element, Single Phase, 2 Wire 1 Element, Single Phase, 2 Wire 11/2 Element, Single Phase, 3 Wire L1 LINE L1 - DC OUTPUT 1 7 L1 L2 - + 2 3 8 9 4 10 5 11 6 12 DC OUTPUT 1 6A 7 12A LINE N 11/2 Element, Single Phase, 3 Wire LINE L1 L2 LINE N Digilogic WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) L2 L2 - DC OUTPUT - + DC OUTPUT + + 2 3 8 9 4 10 5 11 6 12 6A 1 2 3 4 5 6 6A 7 8 9 10 11 12 12A 1 2 3 4 5 6 6A 7 8 9 10 11 12 12A 12A LOAD LOAD EXTERNAL AUX. POWER EXTERNAL AUX. POWER 11/2 Element, 3 Phase, 3 Wire, Delta - DC OUTPUT 1 7 LINE L2 L3 L1 + 2 3 8 9 4 10 5 11 6 12 11/2 Element, 3 Phase, 3 Wire, Delta 2 Element, 3 Phase, 3 Wire, Delta L1 6A DC OUTPUT 1 12A 7 LINE L2 L1 + 2 3 8 9 4 10 5 11 6 12 DC OUTPUT - DC OUTPUT 1 2 3 4 5 6 6A 1 2 3 4 5 6 6A 7 8 9 10 11 12 12A 7 8 9 10 11 12 12A L2 L3 EXTERNAL AUX. POWER LOAD 21/2 Element, 3 Phase, 4 Wire, Wye LINE L1 N L2 LOAD 3 Element, 3 Phase, 4 Wire, Wye LINE L1 N - 1 - + 2 3 4 5 6 DC OUTPUT 1 6A 2 DC OUTPUT L3 N LINE 3 4 5 6 9 10 11 12 - 2 3 4 5 6 6A EXTERNAL AUX. POWER 12A 7 8 DC OUTPUT 9 10 11 12 1 2 3 4 5 6 6A EXTERNAL AUX. POWER 12A LOAD 8 9 10 11 12 12A 7 8 9 10 11 12 12A LOAD LOAD Adjust A2 Models: Shown. A4 Models: External aux. power not required. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 LOAD A2 Models: Shown. A4 Models: External aux. power not required. Fax: 585-454-7805 14 SCI Transducer Cat. 1-51(MTD) N + EXTERNAL AUX. POWER 7 Adjust L3 6A EXTERNAL AUX. POWER 8 + L2 + 1 7 L3 + L1 DC OUTPUT LINE L2 LOAD 3 Element, 3 Phase, 4 Wire, Wye L3 L1 12A LINE L2 2 Element, 3 Phase, 3 Wire, Delta L3 + EXTERNAL AUX. POWER L1 LOAD 6A EXTERNAL AUX. POWER 21/2 Element, 3 Phase, 4 Wire, Wye LINE L2 EXTERNAL AUX. POWER L3 - LOAD EXTERNAL AUX. POWER NOTE: For units with -8 option, connect current input to terminals 7 (•) & 10. LOAD EXTERNAL AUX. POWER NOTE: For units with -8 option, connect current input to terminals 7 (•) & 10. 15 14-15 1/9/02, 5:23 PM SCIENTIFIC Digilogic AC Watt/Watthour or Var/Varhour Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS DIGILOGIC AC WATT/WATTHOUR OR VAR/VARHOUR TRANSDUCERS Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Features ◆ Accuracy to 0.1% of reading Applications ◆ Utility billing Outputs ◆ 0 to ±1 mAdc ◆ Analog & digital outputs ◆ Test laboratories ◆ 1–5 or 1–3–5 mAdc ◆ Exceptional reliability ◆ Process control ◆ 4–20 or 4–12–20 mAdc ◆ Excellent long-term stability ◆ 10–50 or 10–30–50 mAdc ◆ Wide selection of current & voltage input ranges ◆ Relay and solid-state outputs for watthour and varhour functions 0 to ±1 mAdc Watts (Watt/Watthour Transducer) 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* Temperature Effect on Accuracy ±0.005% / ° C ±0.0065% / ° C ±0.009% / ° C ± 0.01% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc Load 0–10,000 Ω Output Ripple Peak < 0.5% RO Relay Contact Rating (-60XX option) See Table 2 on page 14. 0–10,000 Ω < 0.25% RO < 0.25% RO < 0.5% RO 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. One billion operations when operated within specifications. Relay Contact Life (-60XX option) Solid-State Output Contact Rating (-62XX option) 28 Vdc (maximum) VCESAT: 1 Vdc (maximum) at 7 mAdc < 400 ms to 99% < 1 Second to 99% < 1 Second to 99% < 400 ms to 99% Any ±0.04% VA (maximum) (Included in Accuracy specification above.) PF Effect on Accuracy Standard Calibration Adjustments 10 Vdc See Table 2 on page 14. Power Factor Gain Zero ±1% of Reading (minimum) ±10% of Span (minimum) None Required ± 5% of Zero Point (minimum) Stability (per year) ± 0.05% RO, Noncumulative The Digilogic Transducer is recognized as the premier power-system parameter-measurement device. A new twist in DL application results from the exceptional long-term stability of the patented Digilogic design. Many Scientific Columbus customers have found that the accuracy and stability of our Digilogic Transducers rival or exceed the precision of their best laboratory standards. As one Scientific Columbus customer stated, “If my standard indicates that one of my Digilogic Transducers is no longer accurate, I send the standard in for repair!” Approximate Dimensions (excluding mounting plate) 0–95% Noncondensing 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Surge Withstand Overrange with Linearity ±0.2% of Span, Noncumulative ±0.1% RO, Noncumulative Complete (Input/Output/Power/Case) All KYZ outputs are isolated. Dielectric Withstand Maximum Net Weight 60 Hz ±0.1% of Span, Noncumulative Operating Humidity Isolation ±1% of Reading (minimum) ±10% of Span (minimum) None Required ± 5% of Zero Point (minimum) 58–62 Hz Frequency Range 4 lbs., 12 oz. (2.2 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 5 lbs., 2 oz. (2.3 kg) 4 lbs., 14 oz. (2.2 kg) 7.2" W x 5.3" D x 5.8" H 7.0" W x 3.7" D x 5.6" H (183 mm x 135 mm x 147 mm) (178 mm x 94 mm x 142 mm) Style V Case, see page 123 Style I Case, see page 122 500–600 Watts/Element 5 lbs., 4 oz. (2.4 kg) 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. AMETEK® Power Instruments 16 SCI Transducer Cat. 1-51(MTD) P-Option* Vars (Var/Varhour Transducer) ±(0.09% Reading + 0.005% RO) ±(0.1% Reading + 0.05% RO) ± (0.15% Reading + 0.01% RO) ± (0.15% Reading + 0.05% RO) at 0–200% RO at 0–120% RO at 0–120% RO at 0–200% RO Accuracy Response Time Digilogic Transducers Used to Calibrate Accuracy Standards 0 to ±1 mAdc Vars (Var/Varhour Transducer) P-Option* Watts (Watt/Watthour Transducer) Digilogic Digilogic combined watt/watthour and var/varhour transducers provide high accuracy with two simultaneous outputs: an analog output directly proportional to instantaneous watts or vars, and a digital (pulse) output (Form-C mercury-wetted relay or solid-state) directly proportional to watthours or varhours. All models are available in either unidirectional or bidirectional configurations. 255 North Union Street Rochester, New York 14605 Specifications subject to change without notice. Phone: 1-800-274-5368 Fax: 585-454-7805 17 16-17 1/9/02, 5:23 PM SCIENTIFIC Specifications COLUMBUS SCIENTIFIC Digilogic AC Watt/Watthour or Var/Varhour Transducers COLUMBUS DIGILOGIC AC WATT/WATTHOUR OR VAR/VARHOUR TRANSDUCERS Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Features Applications ◆ Accuracy to 0.1% of reading ◆ Utility billing Outputs ◆ 0 to ±1 mAdc ◆ Analog & digital outputs ◆ Test laboratories ◆ 1–5 or 1–3–5 mAdc ◆ Exceptional reliability ◆ Process control ◆ 4–20 or 4–12–20 mAdc ◆ Excellent long-term stability ◆ 10–50 or 10–30–50 mAdc ◆ Wide selection of current & voltage input ranges ◆ Relay and solid-state outputs for watthour and varhour functions 0 to ±1 mAdc Watts (Watt/Watthour Transducer) 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* Temperature Effect on Accuracy ±0.005% / ° C ±0.0065% / ° C ±0.009% / ° C ± 0.01% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc Load 0–10,000 Ω Output Ripple Peak < 0.5% RO Relay Contact Rating (-60XX option) One billion operations when operated within specifications. Solid-State Output Contact Rating (-62XX option) 28 Vdc (maximum) VCESAT: 1 Vdc (maximum) at 7 mAdc < 400 ms to 99% < 1 Second to 99% ±0.04% VA (maximum) (Included in Accuracy specification above.) Gain Zero Stability (per year) ±1% of Reading (minimum) ±10% of Span (minimum) None Required ± 5% of Zero Point (minimum) The Digilogic Transducer is recognized as the premier power-system parameter-measurement device. A new twist in DL application results from the exceptional long-term stability of the patented Digilogic design. Many Scientific Columbus customers have found that the accuracy and stability of our Digilogic Transducers rival or exceed the precision of their best laboratory standards. As one Scientific Columbus customer stated, “If my standard indicates that one of my Digilogic Transducers is no longer accurate, I send the standard in for repair!” Approximate Dimensions (excluding mounting plate) 0–95% Noncondensing 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 4 lbs., 12 oz. (2.2 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 5 lbs., 2 oz. (2.3 kg) 4 lbs., 14 oz. (2.2 kg) 7.2" W x 5.3" D x 5.8" H 7.0" W x 3.7" D x 5.6" H (183 mm x 135 mm x 147 mm) (178 mm x 94 mm x 142 mm) Style V Case, see page 123 Style I Case, see page 122 500–600 Watts/Element 500–1000 Vars/Element 5 lbs., 4 oz. (2.4 kg) 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. Specifications subject to change without notice. Fax: 585-454-7805 16 SCI Transducer Cat. 1-51(MTD) ±0.2% of Span, Noncumulative ±0.1% RO, Noncumulative Complete (Input/Output/Power/Case) All KYZ outputs are isolated. Surge Withstand Overrange with Linearity 60 Hz ±0.1% of Span, Noncumulative Dielectric Withstand Maximum Net Weight ±1% of Reading (minimum) ±10% of Span (minimum) None Required ± 5% of Zero Point (minimum) 58–62 Hz ± 0.05% RO, Noncumulative Operating Humidity Isolation Phone: 1-800-274-5368 < 1 Second to 99% < 400 ms to 99% Any Frequency Range Rochester, New York 14605 < 0.25% RO < 0.5% RO 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. PF Effect on Accuracy 255 North Union Street See Table 2 on page 14. 0–10,000 Ω < 0.25% RO Relay Contact Life (-60XX option) Standard Calibration Adjustments 10 Vdc See Table 2 on page 14. Power Factor AMETEK® Power Instruments P-Option* Vars (Var/Varhour Transducer) ±(0.09% Reading + 0.005% RO) ±(0.1% Reading + 0.05% RO) ± (0.15% Reading + 0.01% RO) ± (0.15% Reading + 0.05% RO) at 0–200% RO at 0–120% RO at 0–120% RO at 0–200% RO Accuracy Response Time Digilogic Transducers Used to Calibrate Accuracy Standards 0 to ±1 mAdc Vars (Var/Varhour Transducer) P-Option* Watts (Watt/Watthour Transducer) Digilogic Digilogic combined watt/watthour and var/varhour transducers provide high accuracy with two simultaneous outputs: an analog output directly proportional to instantaneous watts or vars, and a digital (pulse) output (Form-C mercury-wetted relay or solid-state) directly proportional to watthours or varhours. All models are available in either unidirectional or bidirectional configurations. 17 16-17 1/9/02, 5:23 PM Ordering Procedure Digilogic AC Watt/Watthour or Var/Varhour Transducers Ordering Procedure Digilogic AC Watt/Watthour or Var/Varhour Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Description Output Auxiliary Power Pulse Output Mounting Orientation Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 Ext. Aux. Power A2*** A4 Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 5 Table 6 Table 7 Table 7 Table 3 (P-Option Units) A2*** (leave blank) A4 A2 -6070 PAN7 A4 Burden External Auxiliary Power (120 Vac std.) 85-135 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) 100-130 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA *** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) DLV31K521/2 P-Option outputs Frequency Range Digilogic Base Model No. 0 to ±1 mAdc output Input Range (0 to ±1 mAdc Units) -V -5 Specify counts per hour -1 -RS -SM Specify output voltage If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. DC external auxiliary power available; see Special Options on page 128. -SC Table 4 Pulse Output Selection Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Option -6070 -6270 -6096 -6296 Description Form-C Mercury-Wetted Relay, Unidirectional Form-C Solid-State, Unidirectional Form-C Mercury-Wetted Relay, Bidirectional Form-C Solid-State, Bidirectional CPH Range**** 2-14,000 2-900,000 2-14,000 2-900,000 Mounting Orientation***** -V (Vertical) or -H (Horizontal) Not Applicable -V (Vertical) or -H (Horizontal) Not Applicable **** Standard cph is one count/watthour or varhour unless otherwise specified. ***** You must specify the desired mounting orientation for units with mercury-wetted relays. Table 5 Input Selection EXAMPLES: DLV31K521/2A2-6070-V-5-1-RS-SM-SC Current 21/2-element, 0 to ±1 mAdc Var/Varhour Transducer; 120 Vac external auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). DLV31K521/2PAN7A4-6070-V-5-1-RS-SM-SC 21/2-element, 4-20 mAdc Var/Varhour Transducer; internal auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Element 1 2 21/2* 3 Var Model No. DLV5C5 DLV31K5 DLV31K521/2 DLV342K5 Current Range w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A 0-30 A Connection Single Phase 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire * 21/2-element units require a balanced voltage. Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element † Leave "Input" positions blank in the model number. Option -RS††† -6 -12 -6-RS††† -12-RS††† Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor ††† You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 7 Other Options P-Option** PAN6 PAN7 PAN8 PAN6-B PAN7-B PAN8-B Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc ** PAN models take -6070 or -6270 unidirectional pulse outputs; PAN-B models take -6096 or -6296 bidirectional pulse outputs. Option -SC†††† -SM -Z Description Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option unidirectional units) †††† You must specify the desired input value: 0 to ±1 mAdc units can be calibrated within 90-180% of their standard-calibration input watts or vars. (Example: A 2-element watt/watthour transducer is calibrated to 1000 W standard. The -SC option can be added for input levels from 900 W (90%) to 1800 W (180%).) P-Option units can be calibrated within 60-180% of their standard-calibration input watts or vars. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. AMETEK® Power Instruments 18 SCI Transducer Cat. 1-51(MTD) Calibration at Rated Output (5 A Nominal Input) Option 100 W or Vars/Element -0 250 W or Vars/Element Std.† 500 W or Vars/Element -1 750 W or Vars/Element -9 1000 W or Vars/Element -2 1500 W or Vars/Element 2500 W or Vars/Element Table 6 Scaling Resistor (-RS)/Frequency Options Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A 25 A †† Option -8 requires a Style V case. (See page 123 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) Table 1 Base Model Number Selection Watt Model No. DL5C5 DL31K5 DL31K521/2 DL342K5 Option -3 -4 Std.† -11 -5 -7 -8†† Voltage 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 19 18-19 1/9/02, 5:23 PM Ordering Procedure Digilogic AC Watt/Watthour or Var/Varhour Transducers Ordering Procedure Digilogic AC Watt/Watthour or Var/Varhour Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Description Output Auxiliary Power Pulse Output Mounting Orientation Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 Ext. Aux. Power A2*** A4 Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 5 Table 6 Table 7 Table 7 Table 3 (P-Option Units) A2*** (leave blank) A4 A2 -6070 PAN7 A4 Burden External Auxiliary Power (120 Vac std.) 85-135 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) 100-130 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA *** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) DLV31K521/2 P-Option outputs Frequency Range Digilogic Base Model No. 0 to ±1 mAdc output Input Range (0 to ±1 mAdc Units) -V -5 Specify counts per hour -1 -RS -SM Specify output voltage If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. DC external auxiliary power available; see Special Options on page 128. -SC Table 4 Pulse Output Selection Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Option -6070 -6270 -6096 -6296 Description Form-C Mercury-Wetted Relay, Unidirectional Form-C Solid-State, Unidirectional Form-C Mercury-Wetted Relay, Bidirectional Form-C Solid-State, Bidirectional CPH Range**** 2-14,000 2-900,000 2-14,000 2-900,000 Mounting Orientation***** -V (Vertical) or -H (Horizontal) Not Applicable -V (Vertical) or -H (Horizontal) Not Applicable **** Standard cph is one count/watthour or varhour unless otherwise specified. ***** You must specify the desired mounting orientation for units with mercury-wetted relays. Table 5 Input Selection EXAMPLES: DLV31K521/2A2-6070-V-5-1-RS-SM-SC Current 21/2-element, 0 to ±1 mAdc Var/Varhour Transducer; 120 Vac external auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). DLV31K521/2PAN7A4-6070-V-5-1-RS-SM-SC 21/2-element, 4-20 mAdc Var/Varhour Transducer; internal auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Element 1 2 21/2* 3 Var Model No. DLV5C5 DLV31K5 DLV31K521/2 DLV342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire * 21/2-element units require a balanced voltage. Option -RS††† -6 -12 -6-RS††† -12-RS††† Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor P-Option** PAN6 PAN7 PAN8 PAN6-B PAN7-B PAN8-B Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Option -SC†††† -SM Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element † Leave "Input" positions blank in the model number. ††† You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. -Z Description Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option unidirectional units) †††† You must specify the desired input value: 0 to ±1 mAdc units can be calibrated within 90-180% of their standard-calibration input watts or vars. (Example: A 2-element watt/watthour transducer is calibrated to 1000 W standard. The -SC option can be added for input levels from 900 W (90%) to 1800 W (180%).) P-Option units can be calibrated within 60-180% of their standard-calibration input watts or vars. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. Fax: 585-454-7805 18 SCI Transducer Cat. 1-51(MTD) Calibration at Rated Output (5 A Nominal Input) Option 100 W or Vars/Element -0 250 W or Vars/Element Std.† 500 W or Vars/Element -1 750 W or Vars/Element -9 1000 W or Vars/Element -2 1500 W or Vars/Element 2500 W or Vars/Element Table 7 Other Options ** PAN models take -6070 or -6270 unidirectional pulse outputs; PAN-B models take -6096 or -6296 bidirectional pulse outputs. AMETEK® Power Instruments Current Range w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A 0-30 A Table 6 Scaling Resistor (-RS)/Frequency Options Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A 25 A †† Option -8 requires a Style V case. (See page 123 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) Table 1 Base Model Number Selection Watt Model No. DL5C5 DL31K5 DL31K521/2 DL342K5 Option -3 -4 Std.† -11 -5 -7 -8†† Voltage 19 18-19 1/9/02, 5:23 PM Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) 21/2 Element, 3 Phase, 4 Wire, Wye -6270/-6296 Models -6070/-6096 Models - DC OUTPUT 1 L1 3 4 5 6 A B C D DC OUTPUT 1 L1 L2 - + 2 3 4 5 6 A B C LINE LINE LINE L2 + 2 -6270/-6296 Models -6070/-6096 Models LINE L1 DC OUTPUT 1 D L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G 7 H LOAD 8 9 10 11 12 E F G L2 L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 Digilogic 1 Element, Single Phase, 2 Wire 7 H 8 9 10 11 12 E F G H LOAD EXTERNAL AUX. POWER EXTERNAL AUX. POWER LOAD LOAD Omitted on -6070 Models Omitted on -6070 Models Omitted on -6270 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070/-6096 Models -6270/-6296 Models L1 - DC OUTPUT 1 2 LINE L2 L1 L3 - + 3 4 5 6 A B C D -6070/-6096 Models DC OUTPUT 1 2 LINE L2 LINE L3 L1 8 9 10 11 12 E F G H 7 8 3 4 5 6 A B C - D LOAD Omitted on -6070 Models LINE L3 DC OUTPUT L1 N 9 10 11 12 E F G - + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER + 1 2 3 4 5 6 A B C D 8 9 10 11 12 E F G EXTERNAL AUX. POWER H 7 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models Adjust A2 Models: Shown. A4 Models: External aux. power not required. Adjust AMETEK® Power Instruments 20 SCI Transducer Cat. 1-51(MTD) L2 DC OUTPUT EXTERNAL AUX. POWER H 7 EXTERNAL AUX. POWER L2 + 1 7 -6270/-6296 Models LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 21 20-21 1/9/02, 5:23 PM Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) 21/2 Element, 3 Phase, 4 Wire, Wye -6270/-6296 Models -6070/-6096 Models - DC OUTPUT 1 L1 3 4 5 6 A B C D DC OUTPUT 1 L1 L2 - + 2 3 4 5 6 A B C LINE LINE LINE L2 + 2 -6270/-6296 Models -6070/-6096 Models LINE L1 DC OUTPUT 1 D L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G 7 H LOAD 8 9 10 11 12 E F G L2 L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 Digilogic 1 Element, Single Phase, 2 Wire 7 H 8 9 10 11 12 E F G H LOAD EXTERNAL AUX. POWER EXTERNAL AUX. POWER LOAD LOAD Omitted on -6070 Models Omitted on -6070 Models Omitted on -6270 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070/-6096 Models -6270/-6296 Models L1 - DC OUTPUT 1 2 LINE L2 L1 L3 - + 3 4 5 6 A B C D -6070/-6096 Models DC OUTPUT 1 2 LINE L2 LINE L3 L1 8 9 10 11 12 E F G H 7 8 3 4 5 6 A B C - D LOAD LINE L3 DC OUTPUT L1 N 9 10 11 12 E F G 2 3 4 5 6 A B C D + 1 8 9 10 11 12 E F G 2 3 4 5 6 A B C D EXTERNAL AUX. POWER H 7 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models Adjust Adjust A2 Models: Shown. A4 Models: External aux. power not required. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. Fax: 585-454-7805 20 SCI Transducer Cat. 1-51(MTD) L2 DC OUTPUT EXTERNAL AUX. POWER H EXTERNAL AUX. POWER Omitted on -6070 Models - + 7 EXTERNAL AUX. POWER L2 + 1 7 -6270/-6296 Models 21 20-21 1/9/02, 5:23 PM Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) 21/2 Element, 3 Phase, 4 Wire, Wye -6270/-6296 Models -6070/-6096 Models LINE - DC OUTPUT 1 L2 L1 - + 2 3 4 5 6 A B C D DC OUTPUT 1 L1 - 3 4 5 6 A B C LINE LINE L2 + 2 -6270/-6296 Models -6070/-6096 Models LINE L1 D DC OUTPUT 1 L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 LOAD 8 9 EXTERNAL AUX. POWER 10 11 12 E F G H 7 LOAD 8 9 10 11 12 E F G L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 L2 Digilogic 1 Element, Single Phase, 2 Wire H 7 8 9 10 11 12 E F G H EXTERNAL AUX. POWER Omitted on -6070 Models LOAD LOAD Omitted on -6270 Models Omitted on -6070 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070/-6096 Models -6270/-6296 Models L1 LINE L2 L1 L3 LINE L2 -6070/-6096 Models -6270/-6296 Models L3 LINE L1 - DC OUTPUT - + DC OUTPUT 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT + 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G LOAD Omitted on -6070 Models L1 - 2 3 4 5 6 A B C D + EXTERNAL AUX. POWER 1 2 3 4 5 6 A B C D 8 9 10 11 12 E F G EXTERNAL AUX. POWER 7 H 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models A2 Models: Shown. A4 Models: External aux. power not required. Adjust Adjust AMETEK® Power Instruments 22 SCI Transducer Cat. 1-51(MTD) L2 DC OUTPUT EXTERNAL AUX. POWER H 7 EXTERNAL AUX. POWER N D 1 7 LINE L3 + 1 L2 LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 23 22-23 1/9/02, 5:23 PM Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Digilogic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) 21/2 Element, 3 Phase, 4 Wire, Wye -6270/-6296 Models -6070/-6096 Models LINE - DC OUTPUT 1 L2 L1 - + 2 3 4 5 6 A B C D DC OUTPUT 1 L1 - 3 4 5 6 A B C LINE LINE L2 + 2 -6270/-6296 Models -6070/-6096 Models LINE L1 D DC OUTPUT 1 L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 LOAD 8 9 EXTERNAL AUX. POWER 10 11 12 E F G H 7 LOAD 8 9 10 11 12 E F G L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 L2 Digilogic 1 Element, Single Phase, 2 Wire H 7 8 9 10 11 12 E F G H EXTERNAL AUX. POWER Omitted on -6070 Models LOAD LOAD Omitted on -6270 Models Omitted on -6070 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070/-6096 Models -6270/-6296 Models L1 LINE L2 L1 L3 LINE L2 -6070/-6096 Models -6270/-6296 Models L3 LINE L1 - DC OUTPUT - + DC OUTPUT 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT + 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G LOAD L1 2 3 4 5 6 A B C D + 1 2 3 4 5 6 A B C D 8 9 10 11 12 E F G EXTERNAL AUX. POWER 7 H 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models A2 Models: Shown. A4 Models: External aux. power not required. Adjust AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Adjust LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. Fax: 585-454-7805 22 SCI Transducer Cat. 1-51(MTD) L2 DC OUTPUT EXTERNAL AUX. POWER EXTERNAL AUX. POWER Omitted on -6070 Models - H 7 EXTERNAL AUX. POWER N D 1 7 LINE L3 + 1 L2 23 22-23 1/9/02, 5:23 PM SCIENTIFIC Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS DIGILOGIC AC VOLT-AMP OR COMBINED VOLT-AMP/VOLT-AMPHOUR TRANSDUCERS Specifications Digilogic combined volt-amp/volt-amphour transducers provide two simultaneous outputs: an analog output directly proportional to volt-amps and a digital (pulse) output (Form-C mercury-wetted relay or solid-state) directly proportional to volt-amphours. Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A Voltage Input Nominal Range** Overload Continuous Burden/Element 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Volt-Amps/Element Accuracy Features ◆ Accuracy to 0.2% of reading Applications ◆ Utility billing Outputs ◆ 0–1 mAdc ◆ Analog & digital outputs ◆ Test laboratories ◆ 1–5 mAdc ◆ Exceptional reliability ◆ Process control ◆ 4–20 mAdc ◆ Excellent long-term stability ◆ 10–50 mAdc ◆ Wide selection of current & voltage input ranges ◆ Relay and solid-state outputs for volt-amphour function P-Option* Volt-Amps (Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducer) 0–1 mAdc Volt-Amps (Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducer) 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* ±(0.2% Reading + 0.1% RO) at 0–200% RO ±(0.2% Reading + 0.15% RO) at 0–120% RO Temperature Effect on Accuracy ± 0.01% / ° C ±0.015% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C Compliance Voltage 10 Vdc See Table 2 on page 22. 0–10,000 Ω Load < 2% RO Output Ripple Peak Relay Contact Rating (-6070 option) 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. Relay Contact Life (-6070 option) One billion operations when operated within specifications. Solid-State Output Contact Rating (-6270 option) Response Time 28 Vdc (maximum) VCESAT: 1 Vdc (maximum) at 7 mAdc < 400 ms to 99% < 1 Second to 99% Power Factor Any (Included in Accuracy specification above.) PF Effect on Accuracy Standard Calibration Adjustments Gain Zero ±5% of Reading (minimum) None Required ±20% of Span (minimum) ± 5% of Zero Point (minimum) Frequency Range 58–62 Hz Stability (per year) ±0.2% RO, Noncumulative Operating Humidity Isolation 0–95% Noncondensing Complete (Input/Output/Power/Case) All KYZ outputs are isolated. 1500 VRMS at 60 Hz Dielectric Withstand ANSI/IEEE C37.90.1 Surge Withstand Determining Volt-Amphour Levels in Submetering Applications Maximum Volt-Amp Net Weight Volt-Amp/Volt-Amphour Digilogic Transducers can be employed in submetering applications to measure the level of volt-amps or volt-amphours. For example, install a Scientific Columbus Volt-Amp/Volt-Amphour Transducer and a counter to monitor the total system burden consumed by a specific process within your facility. Approximate Dimensions (excluding mounting plate) 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 8.0" W x 7.0" D x 6.0" H (203 mm x 178 mm x 152 mm) Special Case, contact factory for drawing Overrange with Linearity 500–1000 Volt-Amps/Element 500–600 Volt-Amps/Element 4 lbs., 8 oz. (2 kg) 4 lbs., 14 oz. (2.2 kg) 5 lbs., 8 oz. (2.5 kg) 6 lbs. (2.7 kg) No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration volt-amps on units with 0–1 mAdc output. Total input not to exceed 120% of standard-calibration volt-amps on units with P-Option outputs. AMETEK® Power Instruments 24 SCI Transducer Cat. 1-51(MTD) Digilogic Digilogic volt-amp transducers provide a dc output signal proportional to input volt-amps, using an arithmetic RMS volt-amp measurement technique. These transducers are accurate over any range of power factor, are immune to the effects of distorted wave forms, and are stable over time and in wide extremes of environmental conditions. 255 North Union Street Rochester, New York 14605 Specifications subject to change without notice. Phone: 1-800-274-5368 Fax: 585-454-7805 25 24-25 1/9/02, 5:23 PM SCIENTIFIC Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS DIGILOGIC AC VOLT-AMP OR COMBINED VOLT-AMP/VOLT-AMPHOUR TRANSDUCERS Specifications Digilogic combined volt-amp/volt-amphour transducers provide two simultaneous outputs: an analog output directly proportional to volt-amps and a digital (pulse) output (Form-C mercury-wetted relay or solid-state) directly proportional to volt-amphours. Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A Voltage Input Nominal Range** Overload Continuous Burden/Element 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Volt-Amps/Element Accuracy Features Applications ◆ Accuracy to 0.2% of reading ◆ Utility billing Outputs ◆ Analog & digital outputs ◆ Test laboratories ◆ 1–5 mAdc ◆ Exceptional reliability ◆ Process control ◆ 4–20 mAdc 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* ±(0.2% Reading + 0.1% RO) at 0–200% RO ±(0.2% Reading + 0.15% RO) at 0–120% RO Temperature Effect on Accuracy ± 0.01% / ° C ±0.015% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C Compliance Voltage ◆ 0–1 mAdc 10 Vdc See Table 2 on page 22. 0–10,000 Ω Load < 2% RO Output Ripple Peak Relay Contact Rating (-6070 option) Relay Contact Life (-6070 option) ◆ Excellent long-term stability ◆ 10–50 mAdc ◆ Wide selection of current & voltage input ranges ◆ Relay and solid-state outputs for volt-amphour function Solid-State Output Contact Rating (-6270 option) Response Time 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. One billion operations when operated within specifications. 28 Vdc (maximum) VCESAT: 1 Vdc (maximum) at 7 mAdc < 400 ms to 99% < 1 Second to 99% Power Factor Any (Included in Accuracy specification above.) PF Effect on Accuracy Standard Calibration Adjustments Gain Zero ±5% of Reading (minimum) None Required ±20% of Span (minimum) ± 5% of Zero Point (minimum) Frequency Range 58–62 Hz Stability (per year) ±0.2% RO, Noncumulative Operating Humidity Isolation 0–95% Noncondensing Complete (Input/Output/Power/Case) All KYZ outputs are isolated. 1500 VRMS at 60 Hz Dielectric Withstand ANSI/IEEE C37.90.1 Surge Withstand Determining Volt-Amphour Levels in Submetering Applications Maximum Volt-Amp Net Weight Volt-Amp/Volt-Amphour Digilogic Transducers can be employed in submetering applications to measure the level of volt-amps or volt-amphours. For example, install a Scientific Columbus Volt-Amp/Volt-Amphour Transducer and a counter to monitor the total system burden consumed by a specific process within your facility. Approximate Dimensions (excluding mounting plate) 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 8.0" W x 7.0" D x 6.0" H (203 mm x 178 mm x 152 mm) Special Case, contact factory for drawing Overrange with Linearity 500–1000 Volt-Amps/Element 500–600 Volt-Amps/Element 4 lbs., 8 oz. (2 kg) 4 lbs., 14 oz. (2.2 kg) 5 lbs., 8 oz. (2.5 kg) 6 lbs. (2.7 kg) No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration volt-amps on units with 0–1 mAdc output. Total input not to exceed 120% of standard-calibration volt-amps on units with P-Option outputs. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Specifications subject to change without notice. Fax: 585-454-7805 24 SCI Transducer Cat. 1-51(MTD) P-Option* Volt-Amps (Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducer) 0–1 mAdc Volt-Amps (Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducer) Digilogic Digilogic volt-amp transducers provide a dc output signal proportional to input volt-amps, using an arithmetic RMS volt-amp measurement technique. These transducers are accurate over any range of power factor, are immune to the effects of distorted wave forms, and are stable over time and in wide extremes of environmental conditions. 25 24-25 1/9/02, 5:23 PM Ordering Procedure Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers ORDERING PROCEDURE Ordering Procedure Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers Table 3 Auxiliary Power Supply Selection Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Output Auxiliary Power Pulse Output Mounting Orientation Current Input Voltage Input -RS/Freq. Option Option #2 Option #3 Ext. Aux. Power Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 5 Table 6 Table 7 Table 7 Table 3 A2** A4 (P-Option Units) A2** (leave blank) A4 0-1 mAdc output DLVA31K521/2 -6070 PAN7 Frequency Range Burden External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 85-135 Vac 70-112% of Nominal Aux. Power Voltage 50-500 Hz Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 84-108% of Nominal Aux. Power Voltage 50-500 Hz Equals Input Frequency 6 VA 6 VA ** For external auxiliary power voltages other than 120 Vac, you must specify the voltage in the last position of the complete model number. (Example: 240 Vac) A2 P-Option outputs Input Range Digilogic Base Model No. Description (0-1 mAdc Units) -V -5 Specify counts per hour A4 -1 -RS -SM Specify output voltage If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. -SC Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac, 240 Vac, 277 Vac, or 480 Vac DC external auxiliary power available; see Special Options on page 128. Table 4 Pulse Output Selection Option -6070 -6270 Description Form-C Mercury-Wetted Relay, Unidirectional Form-C Solid-State, Unidirectional CPH Range*** 2-14,000 Standard cph is one 2-900,000 count/volt-amphour. Mounting Orientation**** -V (Vertical) or -H (Horizontal) Not Applicable *** You must specify the desired counts per hour. This information is not part of the model number, but must be provided to the factory when you place your order. **** You must specify the desired mounting orientation for units with mercury-wetted relays. Table 5 Input Selection EXAMPLES: Current DLVA31K521/2A2-6070-V-5-1-RS-SM-SC 21/2-element, 0-1 mAdc Volt-Amp/Volt-Amphour Transducer; 120 Vac external auxiliary power; mercury-wetted relay (unidirectional); vertical mounting;10 A input; 240 V input; resistor scaling (example: 0-5 Vdc); seismic brace; special calibration (example: 7200 VA). DLVA31K521/2PAN7A4-6070-V-5-1-RS-SM-SC 21/2-element, 4-20 mAdc Volt-Amp/Volt-Amphour Transducer; internal auxiliary power; mercury-wetted relay (unidirectional); vertical mounting;10 A input; 240 V input; resistor scaling (example: 1-5 Vdc); seismic brace; special calibration (example: 7200 VA). Option -3 -4 Std.† -11 -5 -7 Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A Current Range w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A Voltage Calibration at Rated Output (5 A Nominal Input) 100 VA/Element 250 VA/Element 500 VA/Element 750 VA/Element 1000 VA/Element 1500 VA/Element Option -0 Std.† -1 -9 -2 Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 VA/Element 500 VA/Element 1000 VA/Element 1200 VA/Element 2000 VA/Element † Leave "Input" positions blank in the model number. Table 6 Scaling Resistor(-RS)/Frequency Options Table 1 Base Model Number Selection Element 1 2 21/2* 3 Volt-Amp Model No. DLVA5C5 DLVA31K5 DLVA31K521/2 DLVA342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 VA 1000 VA 1500 VA 1500 VA * 21/2-element units require a balanced voltage. Option -SC††† -SM P-Option PAN6 PAN7 PAN8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor This information is not part of the model number, but must be provided to the factory when you place your order. Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc -Z Description Special Calibration Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option units) ††† You must specify the desired input value: 0-1 mAdc units can be calibrated within 90-180% of their standard calibration input volt-amps. (Example: A 2-element volt-amp/ volt-amphour transducer is calibrated to 1000 VA standard. The -SC option can be added for input levels from 900 VA (90%) to 1800 VA (180%.)) P-Option units can be calibrated within 60-180% of their standard calibration input volt-amps. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any Special Options, or more than three options, you must first consult the factory for pricing and delivery estimates. AMETEK® Power Instruments 26 SCI Transducer Cat. 1-51(MTD) †† You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 kΩ/Vdc (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. Table 7 Other Options Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Option -RS†† -6 -12 -6-RS†† -12-RS†† 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 27 26-27 1/9/02, 5:24 PM Ordering Procedure Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers ORDERING PROCEDURE Ordering Procedure Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers Table 3 Auxiliary Power Supply Selection Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Output Auxiliary Power Pulse Output Mounting Orientation Current Input Voltage Input -RS/Freq. Option Option #2 Option #3 Ext. Aux. Power Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 5 Table 6 Table 7 Table 7 Table 3 A2** A4 (P-Option Units) A2** (leave blank) A4 0-1 mAdc output DLVA31K521/2 -6070 PAN7 Frequency Range Burden External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 85-135 Vac 70-112% of Nominal Aux. Power Voltage 50-500 Hz Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 84-108% of Nominal Aux. Power Voltage 50-500 Hz Equals Input Frequency 6 VA 6 VA ** For external auxiliary power voltages other than 120 Vac, you must specify the voltage in the last position of the complete model number. (Example: 240 Vac) A2 P-Option outputs Input Range Digilogic Base Model No. Description (0-1 mAdc Units) -V -5 -1 Specify counts per hour A4 -RS -SM Specify output voltage If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. -SC Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac, 240 Vac, 277 Vac, or 480 Vac DC external auxiliary power available; see Special Options on page 128. Table 4 Pulse Output Selection Option -6070 -6270 Description Form-C Mercury-Wetted Relay, Unidirectional Form-C Solid-State, Unidirectional CPH Range*** 2-14,000 Standard cph is one 2-900,000 count/volt-amphour. Mounting Orientation**** -V (Vertical) or -H (Horizontal) Not Applicable *** You must specify the desired counts per hour. This information is not part of the model number, but must be provided to the factory when you place your order. **** You must specify the desired mounting orientation for units with mercury-wetted relays. Table 5 Input Selection EXAMPLES: Current DLVA31K521/2A2-6070-V-5-1-RS-SM-SC 21/2-element, 0-1 mAdc Volt-Amp/Volt-Amphour Transducer; 120 Vac external auxiliary power; mercury-wetted relay (unidirectional); vertical mounting;10 A input; 240 V input; resistor scaling (example: 0-5 Vdc); seismic brace; special calibration (example: 7200 VA). DLVA31K521/2PAN7A4-6070-V-5-1-RS-SM-SC 21/2-element, 4-20 mAdc Volt-Amp/Volt-Amphour Transducer; internal auxiliary power; mercury-wetted relay (unidirectional); vertical mounting;10 A input; 240 V input; resistor scaling (example: 1-5 Vdc); seismic brace; special calibration (example: 7200 VA). Option -3 -4 Std.† -11 -5 -7 Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A Current Range w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A Voltage Calibration at Rated Output (5 A Nominal Input) 100 VA/Element 250 VA/Element 500 VA/Element 750 VA/Element 1000 VA/Element 1500 VA/Element Option -0 Std.† -1 -9 -2 Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 VA/Element 500 VA/Element 1000 VA/Element 1200 VA/Element 2000 VA/Element † Leave "Input" positions blank in the model number. Table 6 Scaling Resistor(-RS)/Frequency Options Table 1 Base Model Number Selection Element 1 2 21/2* 3 Volt-Amp Model No. DLVA5C5 DLVA31K5 DLVA31K521/2 DLVA342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 VA 1000 VA 1500 VA 1500 VA * 21/2-element units require a balanced voltage. Option -SC††† -SM AMETEK® Power Instruments P-Option PAN6 PAN7 PAN8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor This information is not part of the model number, but must be provided to the factory when you place your order. Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc -Z Description Special Calibration Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option units) ††† You must specify the desired input value: 0-1 mAdc units can be calibrated within 90-180% of their standard calibration input volt-amps. (Example: A 2-element volt-amp/ volt-amphour transducer is calibrated to 1000 VA standard. The -SC option can be added for input levels from 900 VA (90%) to 1800 VA (180%.)) P-Option units can be calibrated within 60-180% of their standard calibration input volt-amps. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any Special Options, or more than three options, you must first consult the factory for pricing and delivery estimates. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 26 SCI Transducer Cat. 1-51(MTD) †† You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 kΩ/Vdc (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. Table 7 Other Options Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Option -RS†† -6 -12 -6-RS†† -12-RS†† 27 26-27 1/9/02, 5:24 PM Wiring Diagrams Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers Wiring Diagrams Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Style V Case) AND P-OPTION UNITS (Special Case) WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Style V Case) AND P-OPTION UNITS (Special Case) 21/2 Element, 3 Phase, 4 Wire, Wye -6270 Models -6070 Models LINE L2 L1 -6270 Models -6070 Models LINE L1 L2 L1 - DC OUTPUT - + DC OUTPUT + 1 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT L2 L3 L1 N - + DC OUTPUT 1 9 10 11 12 E F G H 7 LOAD 8 9 Omitted on VA Models 2 3 4 5 6 A B C 1 D 2 3 4 5 6 A B C D EXTERNAL AUX. POWER 10 11 12 E F G H LOAD 8 9 10 11 12 E F G 7 H 8 9 10 11 12 E F G H Omitted on VA Models LOAD LOAD Omitted on VA Models Omitted on VA Models 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070 Models -6270 Models L1 LINE L2 L1 L3 LINE L2 -6070 Models L3 -6270 Models LINE LINE L1 - - + DC OUTPUT 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT 9 10 11 12 E F G EXTERNAL AUX. POWER H 7 8 9 10 11 12 E F G 2 3 4 5 6 A B C 2 3 4 5 6 A B C N D EXTERNAL AUX. POWER LOAD 7 8 9 10 11 12 E F G 7 H 8 9 10 11 12 E F G H Omitted on VA Models LOAD LOAD A2 Models: Shown. A4 Models: External aux. power not required. Adjust AMETEK® Power Instruments 28 SCI Transducer Cat. 1-51(MTD) L3 + EXTERNAL AUX. POWER Omitted on VA Models Adjust L2 DC OUTPUT 1 D H LOAD Omitted on VA Models L1 N - + 1 8 L3 D EXTERNAL AUX. POWER 7 L2 + 1 N EXTERNAL AUX. POWER 7 DC OUTPUT L3 + EXTERNAL AUX. POWER 8 L2 D EXTERNAL AUX. POWER 7 LINE LINE Digilogic 1 Element, Single Phase, 2 Wire Omitted on VA Models A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 29 28-29 1/9/02, 5:24 PM Wiring Diagrams Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers Wiring Diagrams Digilogic AC Volt-Amp or Combined Volt-Amp/Volt-Amphour Transducers WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Style V Case) AND P-OPTION UNITS (Special Case) WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Style V Case) AND P-OPTION UNITS (Special Case) 21/2 Element, 3 Phase, 4 Wire, Wye -6270 Models -6070 Models LINE L2 L1 -6270 Models -6070 Models LINE L1 L2 L1 - DC OUTPUT - + DC OUTPUT + 1 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT L2 L3 L1 N - + DC OUTPUT 1 9 10 11 12 E F G H 7 LOAD 8 9 Omitted on VA Models 2 3 4 5 6 A B C 1 D 2 3 4 5 6 A B C D EXTERNAL AUX. POWER 10 11 12 E F G H LOAD 8 9 10 11 12 E F G 7 H 8 9 10 11 12 E F G H Omitted on VA Models LOAD LOAD Omitted on VA Models Omitted on VA Models 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070 Models -6270 Models L1 LINE L2 L1 L3 LINE L2 -6070 Models L3 -6270 Models LINE LINE L1 - - + DC OUTPUT 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT 9 10 11 12 E F G EXTERNAL AUX. POWER H 7 8 9 10 11 12 E F G 2 3 4 5 6 A B C 2 3 4 5 6 A B C LOAD 7 8 9 10 Rochester, New York 14605 Phone: 1-800-274-5368 Adjust 11 12 E F G 7 H 8 9 10 11 12 E F G H LOAD Omitted on VA Models A2 Models: Shown. A4 Models: External aux. power not required. Fax: 585-454-7805 28 SCI Transducer Cat. 1-51(MTD) D Omitted on VA Models A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street N EXTERNAL AUX. POWER LOAD AMETEK® Power Instruments L3 + EXTERNAL AUX. POWER Omitted on VA Models Adjust L2 DC OUTPUT 1 D H LOAD Omitted on VA Models L1 N - + 1 8 L3 D EXTERNAL AUX. POWER 7 L2 + 1 N EXTERNAL AUX. POWER 7 DC OUTPUT L3 + EXTERNAL AUX. POWER 8 L2 D EXTERNAL AUX. POWER 7 LINE LINE Digilogic 1 Element, Single Phase, 2 Wire 29 28-29 1/9/02, 5:24 PM DM-10 DEMAND MANAGER EFFECTIVELY ELIMINATE EXCESS DEMAND CHARGES! Imput Signals All signals are optically isolated, 120 Vac norminal (90-140 V). Output Signal All pulse outputs are by (Form-A) relay contacts rated at 2A ac or dc, 200W. Relay operation is synchronized to the ac line zero crossing to maximize contact life. Maximum value in power consuption means staying within your contractual demand limits. Once you exceed that limit, the costs start adding up. The Scientific Columbus DM-10 Demand Manager accumulates pulses which allows it to predict the demand level obtainable by the end of a demand interval. It also calculates and displays the level of demand to be shed to stay below a contractual level. The DM-10 measures and stores customer demand by using the watthour KYZ pulses from an existing utility billing meter. The Demand Manager provides flexibility by featuring two user-defined alarm set points. The low set point (threshold) allows for internal control and monitoring of a desired demand level. The high threshold is set at the utility’s contractual peak point. The DM-10 Demand Manager features a serial RS-232 communication port for data retrieval. Connecting a portable printer to this port allows the user to obtain demand interval information. In addition, the port can be connected to a PC-compatible computer to download demand history in comma-delimited format for easy spreadsheet analysis. Maximum capacity of 1999 counts. The current demand interval is user-selectable at 15, 30 or 60 minutes. Storage is provided for 3500 sequential demand intervals providing 36 days of storage at 15 minute intervals. Each interval is time-stamped. Exceltronic current and voltage transducers are available as either average-sensing devices calibrated to indicate RMS, or as true-RMS devices. The average-sensing transducers are offered as single units or triple units which combine three individual measurements in one compact enclosure. Average-sensing voltage transducers also are available as expanded-scale voltage transducers. The Exceltronic current and voltage transducers provide a dc output signal proportional to input amps or volts. The dc output is a filtered, true current of 0–1, 1–5, 4–20, or 10–50 mAdc. Exceltronic Demand SCIENTIFIC SCIENTIFIC Exceltronic AC Current or Voltage Transducers COLUMBUS COLUMBUS Demand Count Inputs One set of KYZ inputs (Form-C). Each toggle of the input will increment the demand register. Cumulative Consuption Applications Features Outputs The cumulative total of all input counts is maintained. Register counts to 99,999,999 and then rolls over to zero. ◆ Accuracy to 0.15% of reading ◆ Substation monitoring ◆ 0–1 mAdc ◆ Exceptional reliability ◆ SCADA ◆ 1–5 mAdc Display and Keypad ◆ Excellent long-term stability ◆ Distribution circuit monitoring ◆ 4–20 mAdc The display and keypad are used to view all stored and operational values, set all controllable parameters, and indicate any detected error conditions. ◆ Average-sensing or true-RMS measurement available ◆ Process control ◆ 10–50 mAdc Keypad ◆ Expanded-scale voltage models available Four sealed-membrane keys provide all data entry and control by intuitive selection and scaling techniques. ◆ Most popular models are UL Recognized Serial Output Provides comma-delimited CSV data for downloading to a spreadsheet. The serial port is the master and utilizes X-on/X-off data-stream control. Baud rate is selectable from 300-4800 bps. Normal operation provides all current parameters and all demand intervals since the last download. Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. ◆ Up to six transducers in one module Auxiliary Power ◆ Two, four, or eight modules in one enclosure 90-140 Vac, 50 or 60 Hz, less than 1 A. ◆ Easy to install, expand, or repair Internal Battery ◆ Convenient front-panel access for calibration and outputcurrent jacks available User-replaceable battery provides memory backup and clock operation for up to eight accumulated months of power outage. Minimum life is 10 years without power outage. Battery condition is monitored and displayed. See pages 77–94 for more information. Time-of-Use The DM-10 features one time-of-use setting for operation during peak hours. AMETEK® Power Instruments 30 SCI Transducer Cat. 1-51(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 31 30-31 1/9/02, 5:24 PM DM-10 DEMAND MANAGER EFFECTIVELY ELIMINATE EXCESS DEMAND CHARGES! Imput Signals All signals are optically isolated, 120 Vac norminal (90-140 V). Output Signal All pulse outputs are by (Form-A) relay contacts rated at 2A ac or dc, 200W. Relay operation is synchronized to the ac line zero crossing to maximize contact life. Maximum value in power consuption means staying within your contractual demand limits. Once you exceed that limit, the costs start adding up. The Scientific Columbus DM-10 Demand Manager accumulates pulses which allows it to predict the demand level obtainable by the end of a demand interval. It also calculates and displays the level of demand to be shed to stay below a contractual level. The DM-10 measures and stores customer demand by using the watthour KYZ pulses from an existing utility billing meter. The Demand Manager provides flexibility by featuring two user-defined alarm set points. The low set point (threshold) allows for internal control and monitoring of a desired demand level. The high threshold is set at the utility’s contractual peak point. The DM-10 Demand Manager features a serial RS-232 communication port for data retrieval. Connecting a portable printer to this port allows the user to obtain demand interval information. In addition, the port can be connected to a PC-compatible computer to download demand history in comma-delimited format for easy spreadsheet analysis. Maximum capacity of 1999 counts. The current demand interval is user-selectable at 15, 30 or 60 minutes. Storage is provided for 3500 sequential demand intervals providing 36 days of storage at 15 minute intervals. Each interval is time-stamped. Exceltronic current and voltage transducers are available as either average-sensing devices calibrated to indicate RMS, or as true-RMS devices. The average-sensing transducers are offered as single units or triple units which combine three individual measurements in one compact enclosure. Average-sensing voltage transducers also are available as expanded-scale voltage transducers. The Exceltronic current and voltage transducers provide a dc output signal proportional to input amps or volts. The dc output is a filtered, true current of 0–1, 1–5, 4–20, or 10–50 mAdc. Demand Count Inputs One set of KYZ inputs (Form-C). Each toggle of the input will increment the demand register. Cumulative Consuption Features ◆ Substation monitoring ◆ 0–1 mAdc ◆ Exceptional reliability ◆ SCADA ◆ 1–5 mAdc Display and Keypad ◆ Excellent long-term stability ◆ Distribution circuit monitoring ◆ 4–20 mAdc The display and keypad are used to view all stored and operational values, set all controllable parameters, and indicate any detected error conditions. ◆ Average-sensing or true-RMS measurement available ◆ Process control ◆ 10–50 mAdc Keypad ◆ Expanded-scale voltage models available Four sealed-membrane keys provide all data entry and control by intuitive selection and scaling techniques. ◆ Most popular models are UL Recognized Serial Output Provides comma-delimited CSV data for downloading to a spreadsheet. The serial port is the master and utilizes X-on/X-off data-stream control. Baud rate is selectable from 300-4800 bps. Normal operation provides all current parameters and all demand intervals since the last download. Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. ◆ Up to six transducers in one module ◆ Two, four, or eight modules in one enclosure ◆ Easy to install, expand, or repair Internal Battery ◆ Convenient front-panel access for calibration and outputcurrent jacks available User-replaceable battery provides memory backup and clock operation for up to eight accumulated months of power outage. Minimum life is 10 years without power outage. Battery condition is monitored and displayed. See pages 77–94 for more information. TIFIE Time-of-Use The DM-10 features one time-of-use setting for operation during peak hours. D 30 SCI Transducer Cat. 1-51(MTD) Outputs ◆ Accuracy to 0.15% of reading 90-140 Vac, 50 or 60 Hz, less than 1 A. 255 North Union Street Rochester, NY 14605 Tel: 585-263-7700 Fax: 585-454-7805 E-Mail: [email protected] Applications The cumulative total of all input counts is maintained. Register counts to 99,999,999 and then rolls over to zero. Auxiliary Power Headquarters 50 Fordham Road CER Wilmington, MA 01887 Tel: 978-988-4101 Fax: 978-988-4179 E-Mail: [email protected] Exceltronic Demand SCIENTIFIC SCIENTIFIC Exceltronic AC Current or Voltage Transducers COLUMBUS COLUMBUS 31 30-31 1/9/02, 5:24 PM Specifications Exceltronic AC Average-Sensing Current or Voltage Transducers Specifications Current Input Voltage Input Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element External Input Range Auxiliary Frequency Range Power Burden/Element 0–1 mAdc Amps (Current Transducer) P-Option* Amps (Current Transducer) 5A 0–5 A 0–10 A 20 A 250 A 0.25 VA (maximum) at 5 A 5A 0–5 A 0–6 A 20 A 250 A 0.25 VA (maximum) at 5 A N/A N/A N/A N/A 120 V 0–150 V 0–150 V 180 V 2.2 VA (maximum) at 120 V 120 V 0–150 V 0–165 V 180 V 2.2 VA (maximum) at 120 V None Required 100–130 Vac 50–500 Hz 3 VA Nominal None Required 100–130 Vac 50–500 Hz 3 VA Nominal Rated Output (RO) = 5 A or 150 V/Element 1 mAdc for Standard Calibration Accuracy Standard A4 Models ±(0.15% Reading + 0.1% RO) ±(0.1% Reading + 0.05% RO) ± 0.5% of Span Temperature Effect on Accuracy ±0.01% / ° C Operating Temperature Range -20° C to +60° C Compliance Voltage 10 Vdc 0–10,000 Ω Load Output Ripple Peak Response Time Standard Calibration Adjustments Gain Zero 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* 0–1 mAdc Volts (Voltage Transducer) Current Input 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±(0.15% Reading + 0.1% RO) ±(0.1% Reading + 0.05% RO) ± 0.5% of Span ±0.025% / ° C ± 0.01% / ° C ± 0.025% / ° C -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc See Table 2 on page 30. 0–10,000 Ω See Table 2 on page 30. < 0.25% RO < 0.1% of Span < 400 ms to 99% < 1 Second to 99% < 400 ms to 99% < 1 Second to 99% ±10% of Reading (minimum) ±20% of Span (minimum) ±10% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) None Required ±5% of Zero Point (minimum) 50–500 Hz (specify nominal) ±0.1% RO, Noncumulative Stability (per year) ±0.15% of Span, Noncumulative ±0.25% RO, Noncumulative ±0.3% of Span, Noncumulative 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Case) Complete (Input/Output/Power/Case) Surge Withstand Complete (Input/Output/Power/Case) Single Triple 13 oz. (0.4 kg) 1 lb., 13 oz. (0.8 kg) 2 lbs., 11 oz. (1.2 kg) 3 lbs., 14 oz. (1.8 kg) 13 oz. (0.4 kg) 1 lb., 13 oz. (0.8 kg) 2 lbs., 11 oz. (1.2 kg) 3 lbs., 14 oz. (1.8 kg) Approximate Dimensions (excluding mounting plate) Single 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.2" W x 5.3" D x 5.8" H 4.4" W x 3.9" D x 4.7" H (183 mm x 135 mm x 147 mm) (112 mm x 99 mm x 119 mm) Style V Case, see page 123 Style II Case, see page 122 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. **Dielectric levels as indicated for UL Recognized models; levels may vary on non-UL Recognized models. N/A 120 V 0–150 V 7.5–150 V*** 180 V 0.035 VA (maximum) at 120 V Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element 85–135 Vac 50–500 Hz 2 VA Nominal 100–135 Vac 50–500 Hz 5 VA Nominal 85–135 Vac 50–500 Hz 2 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±(0.15% Reading + 0.1% RO) ± 0.5% of Span ±(0.15% Reading + 0.1% RO) ± 0.5% of Span Temperature Effect on Accuracy ± 0.01% / ° C ± 0.025% / ° C ±0.01% / ° C ±0.025% / ° C Operating Temperature Range -20° C to +60° C 0° C to +50° C -20° C to +60° C 0° C to +50° C External Input Range Auxiliary Frequency Range Power Burden/Element Rated Output (RO) = 5 A or 150 V/Element Accuracy Compliance Voltage 10 Vdc Response Time Standard Calibration Adjustments Gain Zero < 1% RO ≤ 1% of Span < 600 ms to 99% < 2 Seconds to 99% < 1% RO ≤ 1% of Span < 600 ms to 99% < 2 Seconds to 99% ± 5% of Reading (minimum) ±20% of Span (minimum) ±0.1% of RO ±5% of Zero Point (minimum) 2 :1 (maximum) ±0.1% RO, Noncumulative ± 0.1% RO, Noncumulative ±0.15% of Span, Noncumulative ±0.15% of Span, Noncumulative 0–95% Noncondensing Isolation Approximate Dimensions (excluding mounting plate) See Table 2 on page 30. 55–65 Hz (fundamental and through ninth harmonic) (specify nominal) Crest Factor Maximum Net Weight 0–10,000 Ω ± 5% of Reading (minimum) ±20% of Span (minimum) ±0.1% of RO ±5% of Zero Point (minimum) Frequency Range Stability (per year) 10 Vdc See Table 2 on page 30. 0–10,000 Ω Load Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 2 lbs., 1 oz. (0.9 kg) 3 lbs., 8 oz. (1.6 kg) 2 lbs., 1 oz. (0.9 kg) 3 lbs., 8 oz. (1.6 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. ** Operates at reduced accuracy from 0–0.25 Aac. ***Operates at reduced accuracy from 0–7.5 Vac. Specifications subject to change without notice. AMETEK® Power Instruments 32 SCI Transducer Cat. 1-51(MTD) N/A Surge Withstand Maximum Net Weight P-Option* Volts (Voltage Transducer) 0–1 mAdc Volts (Voltage Transducer) 5A 0–5 A 0.25–6 A** 15 A 250 A 0.2 VA (maximum) at 5 A Dielectric Withstand ANSI/IEEE C37.90.1 Triple P-Option* Amps (Current Transducer) Operating Humidity Complete (Input/Output/Case) 2500 VRMS** at 60 Hz Dielectric Withstand Voltage Input 0–1 mAdc Amps (Current Transducer) Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element Output Ripple Peak < 0.25% RO < 0.1% of Span Frequency Range Specifications P-Option* Volts (Voltage Transducer) Exceltronic Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element Specifications Exceltronic AC True-RMS Current or Voltage Transducers 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 33 32-33 1/9/02, 5:24 PM Specifications Exceltronic AC Average-Sensing Current or Voltage Transducers Specifications Current Input Voltage Input Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element External Input Range Auxiliary Frequency Range Power Burden/Element 0–1 mAdc Amps (Current Transducer) P-Option* Amps (Current Transducer) 5A 0–5 A 0–10 A 20 A 250 A 0.25 VA (maximum) at 5 A 5A 0–5 A 0–6 A 20 A 250 A 0.25 VA (maximum) at 5 A N/A N/A N/A N/A 120 V 0–150 V 0–150 V 180 V 2.2 VA (maximum) at 120 V 120 V 0–150 V 0–165 V 180 V 2.2 VA (maximum) at 120 V None Required 100–130 Vac 50–500 Hz 3 VA Nominal None Required 100–130 Vac 50–500 Hz 3 VA Nominal Rated Output (RO) = 5 A or 150 V/Element 1 mAdc for Standard Calibration Accuracy Standard A4 Models ±(0.15% Reading + 0.1% RO) ±(0.1% Reading + 0.05% RO) ± 0.5% of Span Temperature Effect on Accuracy ±0.01% / ° C Operating Temperature Range -20° C to +60° C Compliance Voltage 10 Vdc 0–10,000 Ω Load Output Ripple Peak Response Time Standard Calibration Adjustments Gain Zero 0–1 mAdc Volts (Voltage Transducer) Current Input 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±(0.15% Reading + 0.1% RO) ±(0.1% Reading + 0.05% RO) ± 0.5% of Span ±0.025% / ° C ± 0.01% / ° C ± 0.025% / ° C -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc See Table 2 on page 30. 0–10,000 Ω See Table 2 on page 30. < 0.25% RO < 0.1% of Span < 400 ms to 99% < 1 Second to 99% < 400 ms to 99% < 1 Second to 99% ±10% of Reading (minimum) ±20% of Span (minimum) ±10% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) None Required ±5% of Zero Point (minimum) 50–500 Hz (specify nominal) ±0.1% RO, Noncumulative Stability (per year) ±0.25% RO, Noncumulative ±0.15% of Span, Noncumulative ±0.3% of Span, Noncumulative 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Case) Complete (Input/Output/Power/Case) Surge Withstand Complete (Input/Output/Power/Case) Single Triple 13 oz. (0.4 kg) 1 lb., 13 oz. (0.8 kg) 2 lbs., 11 oz. (1.2 kg) 3 lbs., 14 oz. (1.8 kg) 13 oz. (0.4 kg) 1 lb., 13 oz. (0.8 kg) 2 lbs., 11 oz. (1.2 kg) 3 lbs., 14 oz. (1.8 kg) Approximate Dimensions (excluding mounting plate) Single 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.2" W x 5.3" D x 5.8" H 4.4" W x 3.9" D x 4.7" H (183 mm x 135 mm x 147 mm) (112 mm x 99 mm x 119 mm) Style V Case, see page 123 Style II Case, see page 122 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. **Dielectric levels as indicated for UL Recognized models; levels may vary on non-UL Recognized models. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 N/A 120 V 0–150 V 7.5–150 V*** 180 V 0.035 VA (maximum) at 120 V Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element 85–135 Vac 50–500 Hz 2 VA Nominal 100–135 Vac 50–500 Hz 5 VA Nominal 85–135 Vac 50–500 Hz 2 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* 1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±(0.15% Reading + 0.1% RO) ± 0.5% of Span ±(0.15% Reading + 0.1% RO) ± 0.5% of Span Temperature Effect on Accuracy ± 0.01% / ° C ± 0.025% / ° C ±0.01% / ° C ±0.025% / ° C Operating Temperature Range -20° C to +60° C 0° C to +50° C -20° C to +60° C 0° C to +50° C External Input Range Auxiliary Frequency Range Power Burden/Element Rated Output (RO) = 5 A or 150 V/Element Accuracy Compliance Voltage 10 Vdc Response Time Standard Calibration Adjustments Gain Zero < 1% RO ≤ 1% of Span < 600 ms to 99% < 2 Seconds to 99% ± 5% of Reading (minimum) ±20% of Span (minimum) ±0.1% of RO ±5% of Zero Point (minimum) Frequency Range Approximate Dimensions (excluding mounting plate) See Table 2 on page 30. < 1% RO ≤ 1% of Span < 600 ms to 99% < 2 Seconds to 99% ± 5% of Reading (minimum) ±20% of Span (minimum) ±0.1% of RO ±5% of Zero Point (minimum) 2 :1 (maximum) ±0.1% RO, Noncumulative ±0.15% of Span, Noncumulative ± 0.1% RO, Noncumulative ±0.15% of Span, Noncumulative 0–95% Noncondensing Isolation Maximum Net Weight 0–10,000 Ω 55–65 Hz (fundamental and through ninth harmonic) (specify nominal) Crest Factor Stability (per year) 10 Vdc See Table 2 on page 30. 0–10,000 Ω Load Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 2 lbs., 1 oz. (0.9 kg) 3 lbs., 8 oz. (1.6 kg) 2 lbs., 1 oz. (0.9 kg) 3 lbs., 8 oz. (1.6 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. ** Operates at reduced accuracy from 0–0.25 Aac. ***Operates at reduced accuracy from 0–7.5 Vac. Specifications subject to change without notice. Specifications subject to change without notice. Phone: 1-800-274-5368 Fax: 585-454-7805 32 SCI Transducer Cat. 1-51(MTD) N/A Surge Withstand Maximum Net Weight P-Option* Volts (Voltage Transducer) 0–1 mAdc Volts (Voltage Transducer) 5A 0–5 A 0.25–6 A** 15 A 250 A 0.2 VA (maximum) at 5 A Dielectric Withstand ANSI/IEEE C37.90.1 Triple P-Option* Amps (Current Transducer) Operating Humidity Complete (Input/Output/Case) 2500 VRMS** at 60 Hz Dielectric Withstand Voltage Input 0–1 mAdc Amps (Current Transducer) Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element Output Ripple Peak < 0.25% RO < 0.1% of Span Frequency Range Specifications P-Option* Volts (Voltage Transducer) Exceltronic Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element Specifications Exceltronic AC True-RMS Current or Voltage Transducers 33 32-33 1/9/02, 5:24 PM Ordering Procedure Exceltronic AC Average-Sensing & True-RMS Current or Voltage Transducers Ordering Procedure Exceltronic AC Average-Sensing & True-RMS Current or Voltage Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option Description Input Range Frequency Range Burden (0-1 mAdc Units) 0-1 mAdc output Base Model No. Output Auxiliary Power Table 1 Table 2 Table 3 Current or -RS/Freq. Voltage Input Option #1 Table 4 Table 5 Option #2 Option #3 Ext. Aux. Power Table 6 Table 6 Table 3 VT110A2 -1 VT110 PAN7 A4 -RS -SM Specify output voltage If A2 is selected, leave space blank; specify ext. aux. power voltage at end of model no. (P-Option Units) A2** (leave blank) External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) (voltage units only) A4 -SC Specify input value 85-135 Vac 50-500 Hz 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) DC external auxiliary power available; see Special Options on page 128. If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Table 4 Input Selection Current Units Only Voltage Units Only Calibration at Rated Output EXAMPLES: 2 VA VT110A2-1-RS-SM-SC 0-1 mAdc Average-Sensing Voltage Transducer with 0.25% accuracy, 240 V input, resistor scaling (converts current output to voltage output), seismic brace, special calibration (example: 360 V). VT110PAN7A4-1-RS-SM-SC 4-20 mAdc Average-Sensing Voltage Transducer, internal auxiliary power, 240 V input, resistor scaling (converts current output to voltage output), seismic brace, special calibration (example: 360 V). Output Option -3 Std.*** -5 -8**** Nominal 1A 5A 10 A 25 A Current Range 0-2 A 0-10 A 0-20 A 0-30 A (5 A Nominal Input) 1 A/Element 5 A/Element 10 A/Element 25 A/Element Exceltronic P-Option outputs None required for average-sensing units. A2** (leave blank) External Auxiliary Power (120 Vac std.) (true-RMS units only) Calibration at Rated Option Std.*** -1 -2 Nominal 120 V 240 V 480 V Voltage Range 0-150 V 0-300 V 0-600 V (120 V Nominal Input) 150 V/Element 300 V/Element 600 V/Element *** Leave "Input" positions blank in the model number. **** Option -8 requires a larger case: Style II case for Models CT510A2 and CT510A4; Style I case for Models 4044 and 4074. (See page 132 for case dimensions. Maximum height of terminal strip(s) is 1.07" on units with -8 option.) Table 1 Base Model Number Selection Current Model No. Voltage Model No. Description Current Voltage VT110A2* VT110A4* 3588 3588A4* 3567A Average Sensing, Single Unit Average Sensing, Single Unit Average Sensing, Triple Unit Average Sensing, Triple Unit True RMS, Single Unit 5A 5A 5A 5A 5A 150 V 150 V 150 V 150 V 150 V VT110 3588 3567 Average Sensing, Single Unit Average Sensing, Triple Unit True RMS, Single Unit 5A 5A 5A 150 V 150 V 150 V (0-1 mAdc Units) CT510A2* CT510A4* 4044 4044A4* 4074A (P-Option Units) CT510 4044 4074 Table 5 Scaling Resistor (-RS)/Frequency Options Calibration at Rated Output (5 A or 120 V Nominal Input) * On 0-1 mAdc Average-Sensing Current and Voltage units, A2 and A4 refer to accuracy. A2 denotes 0.25% accuracy, which is the standard/default; A4 denotes 0.15% optional accuracy. On P-Option Current and Voltage units, A2 and A4 refer to auxiliary power (see Table 3). Standard accuracy on P-Option Current and Voltage units is 0.50%. See Specifications on previous pages for more detail. P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Description Scaling Resistor 400 Hz 50 Hz (not UL Recognized) 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor Table 6 Other Options -SC†† -SM -Z Description 24 Vdc Loop-Powered (PA7 models only) (consult factory for specifications—requires a Style III case; see page 122 for case dimensions) Special Calibration (voltage units only) (consult factory for special calibration on current units) Seismic Brace Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units) AMETEK® Power Instruments 34 SCI Transducer Cat. 1-51(MTD) † You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Option -24 Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Option -RS† -6 -12 -6-RS† -12-RS† 255 North Union Street †† You must specify the desired input value: Voltage transducers can be calibrated within 70-120% of the calibration input voltage (150 V), or 105-180 V. Please consult the factory for input ranges other than 105-180 V. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 35 34-35 1/9/02, 5:24 PM Ordering Procedure Exceltronic AC Average-Sensing & True-RMS Current or Voltage Transducers Ordering Procedure Exceltronic AC Average-Sensing & True-RMS Current or Voltage Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option Description Input Range Frequency Range Burden (0-1 mAdc Units) 0-1 mAdc output Base Model No. Output Auxiliary Power Table 1 Table 2 Table 3 Current or -RS/Freq. Voltage Input Option #1 Table 4 Table 5 Option #2 Option #3 Ext. Aux. Power Table 6 Table 6 Table 3 VT110A2 -1 VT110 PAN7 A4 -RS -SM Specify output voltage If A2 is selected, leave space blank; specify ext. aux. power voltage at end of model no. (P-Option Units) A2** (leave blank) External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) (voltage units only) A4 -SC Specify input value 85-135 Vac 50-500 Hz 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) DC external auxiliary power available; see Special Options on page 128. If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Table 4 Input Selection Current Units Only Voltage Units Only Calibration at Rated Output EXAMPLES: 2 VA VT110A2-1-RS-SM-SC 0-1 mAdc Average-Sensing Voltage Transducer with 0.25% accuracy, 240 V input, resistor scaling (converts current output to voltage output), seismic brace, special calibration (example: 360 V). VT110PAN7A4-1-RS-SM-SC 4-20 mAdc Average-Sensing Voltage Transducer, internal auxiliary power, 240 V input, resistor scaling (converts current output to voltage output), seismic brace, special calibration (example: 360 V). Output Option -3 Std.*** -5 -8**** Nominal 1A 5A 10 A 25 A Current Range 0-2 A 0-10 A 0-20 A 0-30 A (5 A Nominal Input) 1 A/Element 5 A/Element 10 A/Element 25 A/Element Exceltronic P-Option outputs None required for average-sensing units. A2** (leave blank) External Auxiliary Power (120 Vac std.) (true-RMS units only) Calibration at Rated Option Std.*** -1 -2 Nominal 120 V 240 V 480 V Voltage Range 0-150 V 0-300 V 0-600 V (120 V Nominal Input) 150 V/Element 300 V/Element 600 V/Element *** Leave "Input" positions blank in the model number. **** Option -8 requires a larger case: Style II case for Models CT510A2 and CT510A4; Style I case for Models 4044 and 4074. (See page 132 for case dimensions. Maximum height of terminal strip(s) is 1.07" on units with -8 option.) Table 1 Base Model Number Selection Current Model No. Voltage Model No. Description Current Voltage VT110A2* VT110A4* 3588 3588A4* 3567A Average Sensing, Single Unit Average Sensing, Single Unit Average Sensing, Triple Unit Average Sensing, Triple Unit True RMS, Single Unit 5A 5A 5A 5A 5A 150 V 150 V 150 V 150 V 150 V VT110 3588 3567 Average Sensing, Single Unit Average Sensing, Triple Unit True RMS, Single Unit 5A 5A 5A 150 V 150 V 150 V (0-1 mAdc Units) CT510A2* CT510A4* 4044 4044A4* 4074A (P-Option Units) CT510 4044 4074 Table 5 Scaling Resistor (-RS)/Frequency Options Calibration at Rated Output (5 A or 120 V Nominal Input) * On 0-1 mAdc Average-Sensing Current and Voltage units, A2 and A4 refer to accuracy. A2 denotes 0.25% accuracy, which is the standard/default; A4 denotes 0.15% optional accuracy. On P-Option Current and Voltage units, A2 and A4 refer to auxiliary power (see Table 3). Standard accuracy on P-Option Current and Voltage units is 0.50%. See Specifications on previous pages for more detail. AMETEK® Power Instruments P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 255 North Union Street Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Rochester, New York 14605 Phone: 1-800-274-5368 Description Scaling Resistor 400 Hz 50 Hz (not UL Recognized) 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor Table 6 Other Options -SC†† -SM -Z Description 24 Vdc Loop-Powered (PA7 models only) (consult factory for specifications—requires a Style III case; see page 122 for case dimensions) Special Calibration (voltage units only) (consult factory for special calibration on current units) Seismic Brace Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units) †† You must specify the desired input value: Voltage transducers can be calibrated within 70-120% of the calibration input voltage (150 V), or 105-180 V. Please consult the factory for input ranges other than 105-180 V. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. Fax: 585-454-7805 34 SCI Transducer Cat. 1-51(MTD) † You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Option -24 Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Option -RS† -6 -12 -6-RS† -12-RS† 35 34-35 1/9/02, 5:24 PM Specifications Exceltronic AC ExpandedScale Voltage Transducers Harmonics TRANSDUCERS IN THE PRESENCE OF HARMONICS Harmonics are becoming a major issue in the quality of utility power signals, and our customers are concerned about their effect on measurement accuracy. Transducers can be affected by harmonics and have been the focal point of many questions and concerns. Two primary questions seem to surface when discussing transducers and harmonics: (1) Whether or not an average-sensing device or a true-RMS transducer should be used when harmonics are present, and (2) What is the performance of a watt or var transducer when harmonics are present? The harmonic performance for Scientific Columbus watt or var transducers is excellent. The design of the watt transducer makes it an inherently true-RMS device, as the multiplication of current and voltage results in the “square” term necessary for the computation. In addition, the analog nature of Scientific Columbus devices gives them an inherently better performance than many digital-sampling devices. Our data shows accurate readings by Scientific Columbus watt transducers up to the 15th-order harmonic. Voltage Input 0–1 mAdc Volts (Expanded-Scale Voltage Transducer) Any 20–60 V span between 90–150 V (customer specified)** 150 V 2 VA (maximum) at 120 V Span/Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Accuracy P-Option* Volts (Expanded-Scale Voltage Transducer) None Required 100–130 Vac 50–500 Hz 3 VA Nominal 0 mAdc at low end of range (customer specified) 1 mAdc at high end of range (customer specified) 1, 4, or 10 mAdc at low end of range (customer specified) 5, 20, or 50 mAdc at high end of range (customer specified) ±0.25% of Input Voltage for 60 Hz ±0.5% of Input Voltage for 60 Hz Temperature Effect on Accuracy ±0.007% / ° C ±0.015% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc See Table 2 on page 34. Load 0–10,000 Ω Output Ripple Peak < 2.5% RO < 2.5% of Span < 400 ms to 99% < 1 Second to 99% ±5% of Span ±5% of Span ±20% of Span ±5% of Span Response Time Standard Calibration Adjustments Gain Zero Frequency Range 55–65 Hz Stability (per year) ±0.25% of Input Voltage, Noncumulative 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Case) Dielectric Withstand Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight Approximate Dimensions (excluding mounting plate) Exceltronic To determine whether to use an average-sensing device or a true-RMS device, it is important to understand the difference between the two. An average-sensing device simply keeps a running average of the continuously varying signal at its input. A true-RMS device actually calculates, in analog circuitry, the root-meansquared value by: (1) Squaring each instantaneous input value, (2) taking the average (or Mean), and then (3) taking the square Root of the result. In a case where the sine wave is not distorted, both the averagesensing and the RMS output values would be the same. However, when a wave form is distorted, the RMS value reflects a truer measure of the wave form. For example, the self-heating in a transmission line is directly proportional to the square of the RMS value of the current wave form, not the square of the average value of the current wave form. In the presence of a distorted wave form, the average-sensing device provides an averaged answer and disregards some of the effects of distortion. Therefore, an RMS device is advantageous when a large harmonic content is present and precise measurement is required (i.e., capacitor banking switching). Specifications 1 lb., 3 oz. (0.5 kg) 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. **Minimum span must be at least 18% of low-end voltage. 3 lbs., 3 oz. (1.4 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. The same holds true for Scientific Columbus var transducers. A var transducer also calculates a true-RMS value, multiplying the current by the voltage, shifted 90 degrees in phase. As long as the frequency of the voltage signal remains at 60 Hz and the voltage signal remains clean (i.e., no harmonics), a true-RMS signal results. Since most harmonic content appears on the current axis, this method produces accurate signals for most users. For more information on transducers and their performance in the presence of harmonics, or for assistance in selecting the proper transducer for your application, please consult the factory at 1-800-950-6686 (U.S. and Canada). AMETEK® Power Instruments 36 SCI Transducer Cat. 1-51(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 37 36-37 1/9/02, 5:24 PM Specifications Exceltronic AC ExpandedScale Voltage Transducers Harmonics TRANSDUCERS IN THE PRESENCE OF HARMONICS Harmonics are becoming a major issue in the quality of utility power signals, and our customers are concerned about their effect on measurement accuracy. Transducers can be affected by harmonics and have been the focal point of many questions and concerns. Two primary questions seem to surface when discussing transducers and harmonics: (1) Whether or not an average-sensing device or a true-RMS transducer should be used when harmonics are present, and (2) What is the performance of a watt or var transducer when harmonics are present? The harmonic performance for Scientific Columbus watt or var transducers is excellent. The design of the watt transducer makes it an inherently true-RMS device, as the multiplication of current and voltage results in the “square” term necessary for the computation. In addition, the analog nature of Scientific Columbus devices gives them an inherently better performance than many digital-sampling devices. Our data shows accurate readings by Scientific Columbus watt transducers up to the 15th-order harmonic. Voltage Input 0–1 mAdc Volts (Expanded-Scale Voltage Transducer) Any 20–60 V span between 90–150 V (customer specified)** 150 V 2 VA (maximum) at 120 V Span/Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Accuracy P-Option* Volts (Expanded-Scale Voltage Transducer) None Required 100–130 Vac 50–500 Hz 3 VA Nominal 0 mAdc at low end of range (customer specified) 1 mAdc at high end of range (customer specified) 1, 4, or 10 mAdc at low end of range (customer specified) 5, 20, or 50 mAdc at high end of range (customer specified) ±0.25% of Input Voltage for 60 Hz ±0.5% of Input Voltage for 60 Hz Temperature Effect on Accuracy ±0.007% / ° C ±0.015% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc See Table 2 on page 34. Load 0–10,000 Ω Output Ripple Peak < 2.5% RO < 2.5% of Span < 400 ms to 99% < 1 Second to 99% ±5% of Span ±5% of Span ±20% of Span ±5% of Span Response Time Standard Calibration Adjustments Gain Zero Frequency Range 55–65 Hz Stability (per year) ±0.25% of Input Voltage, Noncumulative 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Case) Dielectric Withstand Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight Approximate Dimensions (excluding mounting plate) Exceltronic To determine whether to use an average-sensing device or a true-RMS device, it is important to understand the difference between the two. An average-sensing device simply keeps a running average of the continuously varying signal at its input. A true-RMS device actually calculates, in analog circuitry, the root-meansquared value by: (1) Squaring each instantaneous input value, (2) taking the average (or Mean), and then (3) taking the square Root of the result. In a case where the sine wave is not distorted, both the averagesensing and the RMS output values would be the same. However, when a wave form is distorted, the RMS value reflects a truer measure of the wave form. For example, the self-heating in a transmission line is directly proportional to the square of the RMS value of the current wave form, not the square of the average value of the current wave form. In the presence of a distorted wave form, the average-sensing device provides an averaged answer and disregards some of the effects of distortion. Therefore, an RMS device is advantageous when a large harmonic content is present and precise measurement is required (i.e., capacitor banking switching). Specifications 1 lb., 3 oz. (0.5 kg) 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 * P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. **Minimum span must be at least 18% of low-end voltage. 3 lbs., 3 oz. (1.4 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. The same holds true for Scientific Columbus var transducers. A var transducer also calculates a true-RMS value, multiplying the current by the voltage, shifted 90 degrees in phase. As long as the frequency of the voltage signal remains at 60 Hz and the voltage signal remains clean (i.e., no harmonics), a true-RMS signal results. Since most harmonic content appears on the current axis, this method produces accurate signals for most users. For more information on transducers and their performance in the presence of harmonics, or for assistance in selecting the proper transducer for your application, please consult the factory at 1-800-274-5368 (U.S. and Canada). AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 36 SCI Transducer Cat. 1-51(MTD) 37 36-37 1/9/02, 5:24 PM Ordering Procedure Exceltronic AC ExpandedScale Voltage Transducers Ordering Procedure Exceltronic AC ExpandedScale Voltage Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option Description Input Range Frequency Range Burden (0-1 mAdc Units) Base Model No. Output Auxiliary Power Input Range Table 1 Table 2 Table 3 Table 4 External Aux. Power None Required (P-Option Units) A2* (leave blank) A4** 0-1 mAdc output External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA 90–150 V * For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) P-Option outputs PAN7 A4 ** If the A4 option is selected, the voltage measurement range must stay within the Auxiliary Power Input Range of 84-108% of the Nominal Aux. Power Voltage. For example, if the Nominal Aux. Power Voltage is 120 Vac, the Auxiliary Power Input Range must be 100-130 Vac in order to be within 84-108% of 120 Vac. 100–130 V If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. DC external auxiliary power available; see Special Options on page 128. If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Exceltronic 3545 Table 4 Input Selection EXAMPLES: Measurement Range*** 90-150 V 180-300 V 360-600 V 3545 90-150 V 0-1 mAdc Expanded-Scale Voltage Transducer, 90-150 V input range. 3545PAN7A4 100-130 V 4-20 mAdc Expanded-Scale Voltage Transducer, internal auxiliary power, 100-130 V input range. Customer-Specified Span**** 20-60 V 40-120 V 80-240 V *** The standard measurement range is 90-150 V. This information goes in the "Input Range" position in the complete model number. **** The span should equal the maximum Measurement Range value minus the minimum Measurement Range value. Minimum span must be at least 18% of low-end voltage. This information is not part of the model number, but must be provided to the factory when you place your order. Table 1 Base Model Number Selection Model No. 3545 Description Expanded-Scale Voltage, Average Sensing, Single Unit Please consult the factory if you require any options with Expanded-Scale Voltage Transducers. Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc AMETEK® Power Instruments 38 SCI Transducer Cat. 1-51(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 39 38-39 1/9/02, 5:25 PM Ordering Procedure Exceltronic AC ExpandedScale Voltage Transducers Ordering Procedure Exceltronic AC ExpandedScale Voltage Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option Description Input Range Frequency Range Burden (0-1 mAdc Units) Base Model No. Output Auxiliary Power Input Range Table 1 Table 2 Table 3 Table 4 External Aux. Power None Required (P-Option Units) A2* (leave blank) A4** 0-1 mAdc output External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA 90–150 V * For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) P-Option outputs PAN7 A4 ** If the A4 option is selected, the voltage measurement range must stay within the Auxiliary Power Input Range of 84-108% of the Nominal Aux. Power Voltage. For example, if the Nominal Aux. Power Voltage is 120 Vac, the Auxiliary Power Input Range must be 100-130 Vac in order to be within 84-108% of 120 Vac. 100–130 V If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. DC external auxiliary power available; see Special Options on page 128. If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Exceltronic 3545 Table 4 Input Selection EXAMPLES: Measurement Range*** 90-150 V 180-300 V 360-600 V 3545 90-150 V 0-1 mAdc Expanded-Scale Voltage Transducer, 90-150 V input range. 3545PAN7A4 100-130 V 4-20 mAdc Expanded-Scale Voltage Transducer, internal auxiliary power, 100-130 V input range. Customer-Specified Span**** 20-60 V 40-120 V 80-240 V *** The standard measurement range is 90-150 V. This information goes in the "Input Range" position in the complete model number. **** The span should equal the maximum Measurement Range value minus the minimum Measurement Range value. Minimum span must be at least 18% of low-end voltage. This information is not part of the model number, but must be provided to the factory when you place your order. Table 1 Base Model Number Selection Model No. 3545 Description Expanded-Scale Voltage, Average Sensing, Single Unit Please consult the factory if you require any options with Expanded-Scale Voltage Transducers. Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. AMETEK® Power Instruments P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 255 North Union Street Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 38 SCI Transducer Cat. 1-51(MTD) 39 38-39 1/9/02, 5:25 PM Wiring Diagrams Exceltronic AC Current or Voltage Transducers Transducer Accuracy WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Styles III & II Cases) AND P-OPTION UNITS (Styles I & V Cases) 0-1 mAdc Units Triple Current or Voltage (Style II Case) Single Current or Voltage, Expanded-Scale Voltage (Style III Case) + 1 2 3 4 2 3 4 + DC + DC + AC INPUT DC It would be ideal if a measurement device could be specified as a percent-of-reading device; then the uncertainty of any reading would always be known and constant. However, in practical use, a transducer cannot be specified strictly as a percent-of-reading device. All electronic circuits have an inherent offset error, which is accounted for by adding a constant error term (such as % RO) to the accuracy specification. At Scientific Columbus, we express the total accuracy of our transducers as the percent of reading plus the offset error. For example, the accuracy of our typical current transducer (CT510A2) is 0.15% Reading + 0.1% RO. - OUTPUT 1 True-RMS Current or Voltage (Style II Case) EXTERNAL AUX. POWER - 2 3 4 AC INPUT BØ 1 2 3 - OUTPUT 4 AC INPUT CØ AC INPUT - OUTPUT + 1 2 3 4 5 6 Exceltronic 1 AØ DC OUTPUT Accuracy, as defined in this catalog, is “the degree of uncertainty with which a measured value agrees with the ideal value.” So, to understand accuracy, we must first define uncertainty. There are basically two ways to quantify uncertainty in a measured value: as a percentage of the measured value (reading) that varies with the input, or as a percentage of a fixed value. This fixed value can be either rated output (RO) or full scale, which results in a constant uncertainty over the range of inputs. The less the absolute value of the uncertainty, the more accurate the device. AC INPUT DC OUTPUT - UNDERSTANDING TRANSDUCER ACCURACY The chart below depicts the maximum uncertainty for a CT510A2 transducer compared with two competitive units. The operation of the devices is graphed from several input values. Each plot represents a different method of specifying transducer accuracy. Scientific Columbus’ CT510A2 accuracy is shown in bold. Example: CT510A2 - Nominal: 5 Amps, Full Scale: 10 Amps P-Option Units AC INPUT EXTERNAL AUX. POWER - DC OUTPUT AC INPUT + + 1 1 2 3 4 5 2 3 4 6 A PHASE C PHASE 2 3 4 + DC OUTPUT 1 - 1 B PHASE AC INPUT 2 3 4 A B Signal Input (Amps) + - DC OUTPUT Triple Current or Voltage (Style V Case) Maximum Uncertainty (% of Input Signal) Single Current or Voltage, Expanded-Scale Voltage, True-RMS Current or Voltage (Style I Case) DC OUTPUT 0.25% to Full Scale/Span Competitor #1 AC INPUT 0.15% Reading + 0.1% (RO) Scientific Columbus - EXTERNAL AUX. POWER Adj t Adjust AMETEK® Power Instruments 40 SCI Transducer Cat. 1-51(MTD) 0.25% Rated Output (RO) Competitor #2 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 41 40-41 1/9/02, 5:25 PM Wiring Diagrams Exceltronic AC Current or Voltage Transducers Transducer Accuracy WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Styles III & II Cases) AND P-OPTION UNITS (Styles I & V Cases) 0-1 mAdc Units Triple Current or Voltage (Style II Case) Single Current or Voltage, Expanded-Scale Voltage (Style III Case) + 1 2 3 4 2 3 4 + DC + DC + AC INPUT DC It would be ideal if a measurement device could be specified as a percent-of-reading device; then the uncertainty of any reading would always be known and constant. However, in practical use, a transducer cannot be specified strictly as a percent-of-reading device. All electronic circuits have an inherent offset error, which is accounted for by adding a constant error term (such as % RO) to the accuracy specification. At Scientific Columbus, we express the total accuracy of our transducers as the percent of reading plus the offset error. For example, the accuracy of our typical current transducer (CT510A2) is 0.15% Reading + 0.1% RO. - OUTPUT 1 True-RMS Current or Voltage (Style II Case) EXTERNAL AUX. POWER - 2 3 4 AC INPUT BØ 1 2 3 - OUTPUT 4 AC INPUT CØ AC INPUT - OUTPUT + 1 2 3 4 5 6 Exceltronic 1 AØ DC OUTPUT Accuracy, as defined in this catalog, is “the degree of uncertainty with which a measured value agrees with the ideal value.” So, to understand accuracy, we must first define uncertainty. There are basically two ways to quantify uncertainty in a measured value: as a percentage of the measured value (reading) that varies with the input, or as a percentage of a fixed value. This fixed value can be either rated output (RO) or full scale, which results in a constant uncertainty over the range of inputs. The less the absolute value of the uncertainty, the more accurate the device. AC INPUT DC OUTPUT - UNDERSTANDING TRANSDUCER ACCURACY The chart below depicts the maximum uncertainty for a CT510A2 transducer compared with two competitive units. The operation of the devices is graphed from several input values. Each plot represents a different method of specifying transducer accuracy. Scientific Columbus’ CT510A2 accuracy is shown in bold. Example: CT510A2 - Nominal: 5 Amps, Full Scale: 10 Amps P-Option Units AC INPUT EXTERNAL AUX. POWER - DC OUTPUT AC INPUT + + 1 1 2 3 4 5 2 3 4 6 A PHASE C PHASE 2 3 4 + DC OUTPUT 1 - 1 B PHASE AC INPUT 2 3 4 A B Signal Input (Amps) + - DC OUTPUT Triple Current or Voltage (Style V Case) Maximum Uncertainty (% of Input Signal) Single Current or Voltage, Expanded-Scale Voltage, True-RMS Current or Voltage (Style I Case) DC OUTPUT 0.25% to Full Scale/Span Competitor #1 AC INPUT 0.15% Reading + 0.1% (RO) Scientific Columbus - EXTERNAL AUX. POWER Adj t Adjust AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 40 SCI Transducer Cat. 1-51(MTD) 0.25% Rated Output (RO) Competitor #2 41 40-41 1/9/02, 5:25 PM SCIENTIFIC Exceltronic AC Watt or Var Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC AC WATT OR VAR TRANSDUCERS Features Specifications Applications Outputs Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element 0 to ±1 mAdc Watts (Watt Transducer) 120 V 0–150 V 200 V 0.035 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal Rated Output (RO) = 500 Watts or Vars/Element ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ± (0.2% Reading + 0.01% RO) ± (0.2% Reading + 0.05% RO) ± (0.2% Reading + 0.02% RO) ± (0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy Temperature Effect on Accuracy ±0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C ◆ Substation monitoring ◆ 0 to ±1 mAdc ◆ Exceptional reliability ◆ SCADA ◆ 1–5 or 1–3–5 mAdc Load 0–10,000 Ω ◆ Excellent long-term stability ◆ Energy-management systems ◆ 4–20 or 4–12–20 mAdc Output Ripple Peak < 0.5% RO < 0.25% RO ◆ 10–50 or 10–30–50 mAdc Response Time < 400 ms to 99% < 1 Second to 99% ◆ No zero adjustment required ◆ Most popular models are UL Recognized ◆ Distribution monitoring ◆ Process control Compliance Voltage 10 Vdc Gain Zero Stability (per year) < 400 ms to 99% < 1 Second to 99% ±0.15% VA (maximum) ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz ±0.1% RO, Noncumulative Approximate Dimensions (excluding mounting plate) Overrange with Linearity ±0.25% of Span, Noncumulative ±0.2% RO, Noncumulative Complete (Input/Output/Power/Case) 2500 VRMS*** at 60 Hz Surge Withstand Maximum Net Weight 60 Hz ± 0.15% of Span, Noncumulative 0–95% Noncondensing Dielectric Withstand ◆ Convenient front-panel access for calibration and outputcurrent jacks available < 0.25% RO ± 0.1% VA (maximum) Isolation ◆ Easy to install, expand, or repair < 0.5% RO ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) Operating Humidity ◆ Two, four, or eight modules in one enclosure See Table 2 on page 40. 0–10,000 Ω Any PF Effect on Accuracy Standard Calibration Adjustments 10 Vdc See Table 2 on page 40. Power Factor Frequency Range Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. P-Option* Vars (Var Transducer) 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A ◆ Accuracy to 0.2% of reading ◆ Self- or externally powered 0 to ±1 mAdc Vars (Var Transducer) P-Option* Watts (Watt Transducer) Exceltronic Exceltronic watt and var transducers provide utility and industrial users with a high degree of accuracy for applications requiring precise measurements. These transducers provide a dc-output signal proportional to input watts or vars. All models are available with a wide range of input and output options. ANSI/IEEE C37.90.1 3 lbs., 5 oz. (1.5 kg) 4 lbs., 8 oz. (2 kg) 3 lbs., 5 oz. (1.5 kg) 4 lbs., 8 oz. (2 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. ** Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. ***Dielectric levels as indicated for UL Recognized models; levels may vary on non-UL Recognized models. Specifications subject to change without notice. See pages 77–94 for more information. AMETEK® Power Instruments 42 SCI Transducer Cat. 1-51(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 43 42-43 1/9/02, 5:25 PM SCIENTIFIC Exceltronic AC Watt or Var Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC AC WATT OR VAR TRANSDUCERS Features Specifications Applications Outputs Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element 0 to ±1 mAdc Watts (Watt Transducer) 120 V 0–150 V 200 V 0.035 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal Rated Output (RO) = 500 Watts or Vars/Element ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ± (0.2% Reading + 0.01% RO) ± (0.2% Reading + 0.05% RO) ± (0.2% Reading + 0.02% RO) ± (0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy Temperature Effect on Accuracy ±0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C ◆ Substation monitoring ◆ 0 to ±1 mAdc ◆ Exceptional reliability ◆ SCADA ◆ 1–5 or 1–3–5 mAdc Load 0–10,000 Ω ◆ Excellent long-term stability ◆ Energy-management systems ◆ 4–20 or 4–12–20 mAdc Output Ripple Peak < 0.5% RO < 0.25% RO ◆ 10–50 or 10–30–50 mAdc Response Time < 400 ms to 99% < 1 Second to 99% ◆ No zero adjustment required ◆ Most popular models are UL Recognized ◆ Distribution monitoring Compliance Voltage 10 Vdc Standard Calibration Adjustments Gain Zero Stability (per year) < 400 ms to 99% < 1 Second to 99% ±0.15% VA (maximum) ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz ±0.1% RO, Noncumulative Approximate Dimensions (excluding mounting plate) Overrange with Linearity ±0.2% RO, Noncumulative ±0.25% of Span, Noncumulative Complete (Input/Output/Power/Case) 2500 VRMS*** at 60 Hz Surge Withstand Maximum Net Weight 60 Hz ± 0.15% of Span, Noncumulative 0–95% Noncondensing Dielectric Withstand ◆ Convenient front-panel access for calibration and outputcurrent jacks available < 0.25% RO ± 0.1% VA (maximum) Isolation ◆ Easy to install, expand, or repair < 0.5% RO ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) Operating Humidity ◆ Two, four, or eight modules in one enclosure See Table 2 on page 40. 0–10,000 Ω Any Frequency Range Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. 10 Vdc See Table 2 on page 40. Power Factor PF Effect on Accuracy ◆ Process control P-Option* Vars (Var Transducer) 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A ◆ Accuracy to 0.2% of reading ◆ Self- or externally powered 0 to ±1 mAdc Vars (Var Transducer) P-Option* Watts (Watt Transducer) Exceltronic Exceltronic watt and var transducers provide utility and industrial users with a high degree of accuracy for applications requiring precise measurements. These transducers provide a dc-output signal proportional to input watts or vars. All models are available with a wide range of input and output options. ANSI/IEEE C37.90.1 3 lbs., 5 oz. (1.5 kg) 4 lbs., 8 oz. (2 kg) 3 lbs., 5 oz. (1.5 kg) 4 lbs., 8 oz. (2 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. ** Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. ***Dielectric levels as indicated for UL Recognized models; levels may vary on non-UL Recognized models. Specifications subject to change without notice. See pages 77–94 for more information. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 42 SCI Transducer Cat. 1-51(MTD) 43 42-43 1/9/02, 5:25 PM Ordering Procedure Exceltronic AC Watt or Var Transducers Ordering Procedure Exceltronic AC Watt or Var Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option Base Model No. Output Auxiliary Power Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 External Aux. Power Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 6 Table 6 Table 3 0 to ±1 mAdc output Description A2** A4 (P-Option Units) A2** (leave blank) A4 A2 Input Range Frequency Range Burden (0 to ±1 mAdc Units) External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 85-135 Vac 50-500 Hz 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) XL342K5 -5 -1 -RS -SM -SC PAN7 Specify output voltage A4 Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. EXAMPLES: XL342K5A2-5-1-RS-SM-SC 3-element, 0 to ±1 mAdc Watt Transducer; 120 Vac external auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). XL342K5PAN7A4-5-1-RS-SM-SC 3-element, 4-20 mAdc Watt Transducer; internal auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Element 1 11/2* 2 21/2* 3 Var Model No. XLV5C5 XLV5C511/2 XLV31K5 XLV31K521/2 XLV342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars * 11/2- and 21/2-element units require a balanced voltage. Option -3 -4 Std.*** -11 -5 15 A -8**** Option -0 Std.*** -1 -9 -2 Nominal 69 V 120 V 240 V 277 V 480 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element -7 *** Leave "Input" positions blank in the model number. **** Option -8 requires a Style I case. (See page 122 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) Option -RS† -6 -12 -6-RS† -12-RS† Description Scaling Resistor 400 Hz 50 Hz (not UL Recognized) 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor † You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. Table 6 Other Options P-Option PAN6 PAN7 PAN8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω PAN6-B PAN7-B PAN8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc PA6 PA7 PA8 PA6-B PA7-B PA8-B Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc Option -20 -21 -24 -CE -SC†† -SM -Z Description 50-200% Calibration Adjustment (current outputs) 50-200% Calibration Adjustment (voltage outputs) (available only with 0 to ±1 mAdc units) 24 Vdc Loop-Powered (PA7 and PA7-B models only) (consult factory for specifications) Analog Output Shorting Relay (available only with 0 to ±1 mAdc units) Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units, except PAN-B models) AMETEK® Power Instruments 44 SCI Transducer Cat. 1-51(MTD) Voltage Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V This information is not part of the model number, but must be provided to the factory when you place your order. Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Current Current Range Calibration at Rated Output Nominal w/ Accuracy (5 A Nominal Input) 1A 0-2 A 100 W or Vars/Element 2.5 A 0-5 A 250 W or Vars/Element 5A 0-10 A 500 W or Vars/Element 7.5 A 0-15 A 750 W or Vars/Element 10 A 0-20 A 1000 W or Vars/Element 0-20 A1500 W or Vars/Element 25 A 0-30 A 2500 W or Vars/Element Table 5 Scaling Resistor (-RS)/Frequency Options Table 1 Base Model Number Selection Watt Model No. XL5C5 XL5C511/2 XL31K5 XL31K521/2 XL342K5 Table 4 Input Selection Exceltronic DC external auxiliary power available; see Special Options on page 128. P-Option outputs 255 North Union Street †† You must specify the desired input value: 0 to ±1 mAdc units can be calibrated within 90-180% of their standardcalibration input watts or vars. (Example: A 2-element watt transducer is calibrated to 1000 W standard. The -SC option can be added for input levels from 900 W (90%) to 1800 W (180%).) P-Option units can be calibrated within 60-180% of their standard-calibration input watts or vars. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 45 44-45 1/9/02, 5:25 PM Ordering Procedure Exceltronic AC Watt or Var Transducers Ordering Procedure Exceltronic AC Watt or Var Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option Base Model No. Output Auxiliary Power Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 External Aux. Power Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 6 Table 6 Table 3 0 to ±1 mAdc output Description A2** A4 (P-Option Units) A2** (leave blank) A4 A2 Input Range Frequency Range Burden (0 to ±1 mAdc Units) External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 85-135 Vac 50-500 Hz 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) XL342K5 -5 -1 -RS -SM -SC PAN7 Specify output voltage A4 Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. EXAMPLES: XL342K5A2-5-1-RS-SM-SC 3-element, 0 to ±1 mAdc Watt Transducer; 120 Vac external auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). XL342K5PAN7A4-5-1-RS-SM-SC 3-element, 4-20 mAdc Watt Transducer; internal auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Element 1 11/2* 2 21/2* 3 Var Model No. XLV5C5 XLV5C511/2 XLV31K5 XLV31K521/2 XLV342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars * 11/2- and 21/2-element units require a balanced voltage. Nominal 69 V 120 V 240 V 277 V 480 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element -7 *** Leave "Input" positions blank in the model number. **** Option -8 requires a Style I case. (See page 122 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) Option -RS† -6 -12 -6-RS† -12-RS† Description Scaling Resistor 400 Hz 50 Hz (not UL Recognized) 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor P-Option PAN6 PAN7 PAN8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω PAN6-B PAN7-B PAN8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc PA6 PA7 PA8 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc Option -20 -21 -24 -CE -SC†† -SM -Z Description 50-200% Calibration Adjustment (current outputs) 50-200% Calibration Adjustment (voltage outputs) (available only with 0 to ±1 mAdc units) 24 Vdc Loop-Powered (PA7 and PA7-B models only) (consult factory for specifications) Analog Output Shorting Relay (available only with 0 to ±1 mAdc units) Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units, except PAN-B models) † You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. †† You must specify the desired input value: 0 to ±1 mAdc units can be calibrated within 90-180% of their standardcalibration input watts or vars. (Example: A 2-element watt transducer is calibrated to 1000 W standard. The -SC option can be added for input levels from 900 W (90%) to 1800 W (180%).) P-Option units can be calibrated within 60-180% of their standard-calibration input watts or vars. This information is not part of the model number, but must be provided to the factory when you place your order. If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. Fax: 585-454-7805 44 SCI Transducer Cat. 1-51(MTD) Option -0 Std.*** -1 -9 -2 Table 6 Other Options PA6-B PA7-B PA8-B AMETEK® Power Instruments Option -3 -4 Std.*** -11 -5 15 A -8**** Voltage Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V This information is not part of the model number, but must be provided to the factory when you place your order. Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Current Current Range Calibration at Rated Output Nominal w/ Accuracy (5 A Nominal Input) 1A 0-2 A 100 W or Vars/Element 2.5 A 0-5 A 250 W or Vars/Element 5A 0-10 A 500 W or Vars/Element 7.5 A 0-15 A 750 W or Vars/Element 10 A 0-20 A 1000 W or Vars/Element 0-20 A1500 W or Vars/Element 25 A 0-30 A 2500 W or Vars/Element Table 5 Scaling Resistor (-RS)/Frequency Options Table 1 Base Model Number Selection Watt Model No. XL5C5 XL5C511/2 XL31K5 XL31K521/2 XL342K5 Table 4 Input Selection Exceltronic DC external auxiliary power available; see Special Options on page 128. P-Option outputs 45 44-45 1/9/02, 5:25 PM Wiring Diagrams Exceltronic AC Watt or Var Transducers Wiring Diagrams Exceltronic AC Watt or Var Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style II Case) WIRING DIAGRAMS FOR P-OPTION UNITS (Style I Case) 1 Element, Single Phase, 2 Wire 1 Element, Single Phase, 2 Wire 11/2 Element, Single Phase, 3 Wire LINE L1 L2 L1 DC OUTPUT - LINE N LINE L1 L2 DC OUTPUT + - + - 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 DC OUTPUT - + 1 2 3 4 5 6 7 8 9 10 11 12 LOAD 11/2 Element, 3 Phase, 3 Wire, Delta EXTERNAL AUX. POWER LINE L2 2 7 4 3 9 8 - 10 5 11 6 + 1 12 2 7 4 3 9 8 10 5 DC OUTPUT 2 3 4 5 6 7 8 9 10 11 12 LOAD L1 L3 - DC OUTPUT LINE L2 + 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 11 12 LOAD 21/2 Element, 3 Phase, 4 Wire, Wye LOAD LOAD EXTERNAL AUX. POWER 3 Element, 3 Phase, 4 Wire, Wye LINE LINE L1 21/2 Element, 3 Phase, 4 Wire, Wye LINE L2 L3 DC OUTPUT 2 L1 N LINE L2 L3 DC OUTPUT - + 1 3 4 5 6 L2 L3 L1 N + 1 6A 2 N - DC OUTPUT 1 3 4 5 6 - + 2 3 4 5 6 DC OUTPUT 9 10 11 EXT. AUX. POWER 7 12 12A 8 9 10 11 1 6A 2 3 4 5 6 6A EXTERNAL AUX. POWER 7 8 9 10 11 12 7 12A 8 9 10 11 12 12A 12 12A LOAD LOAD LOAD Adj t Adjust A2 Models: Shown. A4 Models: External aux. power not required. LOAD Adjust AMETEK® Power Instruments 46 SCI Transducer Cat. 1-51(MTD) N + EXTERNAL AUX. POWER 8 L3 6A EXT. AUX. POWER 7 L2 3 Element, 3 Phase, 4 Wire, Wye L1 - L3 6 EXTERNAL AUX. POWER LOAD LINE L2 + EXTERNAL AUX. POWER EXTERNAL AUX. POWER L2 2 Element, 3 Phase, 3 Wire, Delta L1 L3 DC OUTPUT + 1 L1 L3 DC OUTPUT - 1 EXTERNAL AUX. POWER 11/2 Element, 3 Phase, 3 Wire, Delta LINE L2 LINE N + NOTE: For units with -8 option, connect current input to terminals 7 (•) & 10. LOAD 2 Element, 3 Phase, 3 Wire, Delta L1 DC OUTPUT LOAD EXTERNAL AUX. POWER NOTES: (1) For units with -8 option, connect current input to terminals 7 (•) and 10 . (2) Bottom terminal strip (7-12) omitted on A4 models, except with -8 option. EXTERNAL AUX. POWER L1 L2 Exceltronic 1 11/2 Element, Single Phase, 3 Wire A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 47 46-47 1/9/02, 5:25 PM Wiring Diagrams Exceltronic AC Watt or Var Transducers Wiring Diagrams Exceltronic AC Watt or Var Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style II Case) WIRING DIAGRAMS FOR P-OPTION UNITS (Style I Case) 1 Element, Single Phase, 2 Wire 1 Element, Single Phase, 2 Wire 11/2 Element, Single Phase, 3 Wire LINE L1 L2 L1 DC OUTPUT - LINE N LINE L1 L2 DC OUTPUT + - + - 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 DC OUTPUT - + 1 2 3 4 5 6 7 8 9 10 11 12 LOAD 11/2 Element, 3 Phase, 3 Wire, Delta EXTERNAL AUX. POWER LINE L2 2 7 4 3 9 8 - 10 5 6 11 + 1 12 2 7 4 3 9 8 10 5 DC OUTPUT 2 3 4 5 6 7 8 9 10 11 12 LOAD L1 L3 - DC OUTPUT LINE L2 + 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 11 12 LOAD 21/2 Element, 3 Phase, 4 Wire, Wye LOAD LOAD EXTERNAL AUX. POWER 3 Element, 3 Phase, 4 Wire, Wye LINE LINE L1 21/2 Element, 3 Phase, 4 Wire, Wye LINE L2 L3 DC OUTPUT 2 L1 N LINE L2 L3 DC OUTPUT - + 1 3 4 5 6 L2 L3 L1 N + 1 6A 2 N - DC OUTPUT 1 3 4 5 6 - + 2 3 4 5 6 DC OUTPUT 9 10 11 EXT. AUX. POWER 7 12 12A 8 9 10 11 1 6A 2 3 4 5 6 6A EXTERNAL AUX. POWER 7 8 9 10 11 12 7 12A 8 9 10 11 12 12A 12 12A LOAD Adj t Adjust A2 Models: Shown. A4 Models: External aux. power not required. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 LOAD LOAD LOAD Phone: 1-800-274-5368 Adjust A2 Models: Shown. A4 Models: External aux. power not required. Fax: 585-454-7805 46 SCI Transducer Cat. 1-51(MTD) N + EXTERNAL AUX. POWER 8 L3 6A EXT. AUX. POWER 7 L2 3 Element, 3 Phase, 4 Wire, Wye L1 - L3 6 EXTERNAL AUX. POWER LOAD LINE L2 + EXTERNAL AUX. POWER EXTERNAL AUX. POWER L2 2 Element, 3 Phase, 3 Wire, Delta L1 L3 DC OUTPUT + 1 L1 L3 DC OUTPUT - 1 EXTERNAL AUX. POWER 11/2 Element, 3 Phase, 3 Wire, Delta LINE L2 LINE N + NOTE: For units with -8 option, connect current input to terminals 7 (•) & 10. LOAD 2 Element, 3 Phase, 3 Wire, Delta L1 DC OUTPUT LOAD EXTERNAL AUX. POWER NOTES: (1) For units with -8 option, connect current input to terminals 7 (•) and 10 . (2) Bottom terminal strip (7-12) omitted on A4 models, except with -8 option. EXTERNAL AUX. POWER L1 L2 Exceltronic 1 11/2 Element, Single Phase, 3 Wire 47 46-47 1/9/02, 5:25 PM SCIENTIFIC Exceltronic Combined AC Watt/Var Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC COMBINED AC WATT/VAR TRANSDUCERS Exceltronic combined watt/var transducers provide all the functions of the individual watt and var transducers, but require only half the panel space and half the wiring. These transducers use a common power supply and share the input voltage and current transformers. Because of this unique feature, the burden on the user’s transformers is the same as when only one watt or var transducer is used. Specifications Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Applications Outputs ◆ Substation line monitoring ◆ Two transducers in one enclosure ◆ Energy-management systems ◆ Excellent long-term stability ◆ Most popular models are UL Recognized ◆ Process control ◆ 0 to ±1 mAdc ◆ 1–5 or 1–3–5 mAdc ◆ 4–20 or 4–12–20 mAdc 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A 120 V 0–150 V 200 V 0.035 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* Temperature Effect on Accuracy ±0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage Load ◆ Accuracy to 0.2% of reading Output Ripple Peak Response Time 10 Vdc 20 Vdc 10 Vdc 20 Vdc 0–10,000 Ω See Table 2 on page 46. 0–10,000 Ω See Table 2 on page 46. < 0.5% RO < 0.25% RO < 0.5% RO < 0.25% RO < 400 ms to 99% < 1 Second to 99% < 400 ms to 99% < 1 Second to 99% Power Factor Any PF Effect on Accuracy Standard Calibration Adjustments Gain Zero ± 0.1% VA (maximum) ±0.15% VA (maximum) ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) Frequency Stability (per year) 60 Hz ±0.1% RO, Noncumulative Operating Humidity ◆ Up to three single-phase watt/var transducers in one module ◆ Two, four, or eight modules in one enclosure ◆ Easy to install, expand, or repair ◆ Convenient front-panel access for calibration and outputcurrent jacks available Overrange with Linearity ± 0.25% of Span, Noncumulative 2500 VRMS*** at 60 Hz ANSI/IEEE C37.90.1 Surge Withstand Approximate Dimensions (excluding mounting plate) ±0.2% RO, Noncumulative Complete (Input/Output/Power/Case) Dielectric Withstand Maximum Net Weight ±0.15% of Span, Noncumulative 0–95% Noncondensing Isolation Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. P-Option* Vars (Combined Watt/Var Transducer) ± (0.2% Reading + 0.01% RO) ± (0.2% Reading + 0.05% RO) ± (0.2% Reading + 0.02% RO) ± (0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy Features 0 to ±1 mAdc Vars (Combined Watt/Var Transducer) P-Option* Watts (Combined Watt/Var Transducer) Exceltronic Current Input 0 to ±1 mAdc Watts (Combined Watt/Var Transducer) 3 lbs., 10 oz. (1.6 kg) 3 lbs., 14 oz. (1.8 kg) 3 lbs., 10 oz. (1.6 kg) 3 lbs., 14 oz. (1.8 kg) 4.4" W x 3.9" D x 6.3" H (112 mm x 99 mm x 160 mm) Style IV Case, see page 123 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5 and 4–20/4–12–20 mAdc outputs. ** Total input not to exceed 200% of standard-calibration watts and vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts and vars on units with P-Option outputs. ***Dielectric levels as indicated for UL Recognized models; levels may vary on non-UL Recognized models. Specifications subject to change without notice. See pages 77–94 for more information. AMETEK® Power Instruments 48 SCI Transducer Cat. 1-51(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 49 48-49 1/9/02, 5:25 PM SCIENTIFIC Exceltronic Combined AC Watt/Var Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC COMBINED AC WATT/VAR TRANSDUCERS Exceltronic combined watt/var transducers provide all the functions of the individual watt and var transducers, but require only half the panel space and half the wiring. These transducers use a common power supply and share the input voltage and current transformers. Because of this unique feature, the burden on the user’s transformers is the same as when only one watt or var transducer is used. Specifications Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Applications Outputs ◆ Substation line monitoring ◆ Two transducers in one enclosure ◆ Energy-management systems ◆ Excellent long-term stability ◆ Most popular models are UL Recognized ◆ Process control ◆ 0 to ±1 mAdc ◆ 1–5 or 1–3–5 mAdc ◆ 4–20 or 4–12–20 mAdc 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A 120 V 0–150 V 200 V 0.035 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* Temperature Effect on Accuracy ±0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage Load ◆ Accuracy to 0.2% of reading Output Ripple Peak Response Time 10 Vdc 20 Vdc 10 Vdc 20 Vdc 0–10,000 Ω See Table 2 on page 46. 0–10,000 Ω See Table 2 on page 46. < 0.5% RO < 0.25% RO < 0.5% RO < 0.25% RO < 400 ms to 99% < 1 Second to 99% < 400 ms to 99% < 1 Second to 99% Power Factor Any PF Effect on Accuracy Standard Calibration Adjustments Gain Zero ± 0.1% VA (maximum) ±0.15% VA (maximum) ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) ±2% of Reading (minimum) ± 20% of Span (minimum) None Required ±5% of Zero Point (minimum) Frequency Stability (per year) 60 Hz ±0.1% RO, Noncumulative Operating Humidity ◆ Up to three single-phase watt/var transducers in one module ◆ Two, four, or eight modules in one enclosure ◆ Easy to install, expand, or repair ◆ Convenient front-panel access for calibration and outputcurrent jacks available Overrange with Linearity ± 0.25% of Span, Noncumulative 2500 VRMS*** at 60 Hz ANSI/IEEE C37.90.1 Surge Withstand Approximate Dimensions (excluding mounting plate) ±0.2% RO, Noncumulative Complete (Input/Output/Power/Case) Dielectric Withstand Maximum Net Weight ±0.15% of Span, Noncumulative 0–95% Noncondensing Isolation Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. P-Option* Vars (Combined Watt/Var Transducer) ± (0.2% Reading + 0.01% RO) ± (0.2% Reading + 0.05% RO) ± (0.2% Reading + 0.02% RO) ± (0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy Features 0 to ±1 mAdc Vars (Combined Watt/Var Transducer) P-Option* Watts (Combined Watt/Var Transducer) Exceltronic Current Input 0 to ±1 mAdc Watts (Combined Watt/Var Transducer) 3 lbs., 10 oz. (1.6 kg) 3 lbs., 14 oz. (1.8 kg) 3 lbs., 10 oz. (1.6 kg) 3 lbs., 14 oz. (1.8 kg) 4.4" W x 3.9" D x 6.3" H (112 mm x 99 mm x 160 mm) Style IV Case, see page 123 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5 and 4–20/4–12–20 mAdc outputs. ** Total input not to exceed 200% of standard-calibration watts and vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts and vars on units with P-Option outputs. ***Dielectric levels as indicated for UL Recognized models; levels may vary on non-UL Recognized models. Specifications subject to change without notice. See pages 77–94 for more information. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 48 SCI Transducer Cat. 1-51(MTD) 49 48-49 1/9/02, 5:25 PM Ordering Procedure Exceltronic Combined AC Watt/Var Transducers Ordering Procedure Exceltronic Combined AC Watt/Var Transducers Table 3 Auxiliary Power Supply Selection ORDERING PROCEDURE Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Description Base Model No. Output Auxiliary Power Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 Ext. Aux. Power A2** A4 Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 6 Table 6 Table 3 (P-Option Units) A2** (leave blank) A4 0 to ±1 mAdc output External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 85-135 Vac 50-500 Hz 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA -1 -RS Specify output voltage A4 PAN7 -SM -SC Specify input value DC external auxiliary power available; see Special Options on page 128. If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. XLWV342K5A2-5-1-RS-SM-SC 3-element, 0 to ±1 mAdc Watt/Var Transducer; 120 Vac external auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). XLWV342K5PAN7A4-5-1-RS-SM-SC 3-element, 4-20 mAdc Watt/Var Transducer; internal auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Watt/Var Model No. XLWV5C5 XLWVW5C511/2 XLWV31K5 XLWV31K521/2 XLWV342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Current Output Option -3 -4 Std.*** -11 -5 -7 Voltage Current Range Calibration at Rated Output w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A (5 A Nominal Input) 100 W or Vars/Element 250 W or Vars/Element 500 W or Vars/Element 750 W or Vars/Element 1000 W or Vars/Element 1500 W or Vars/Element Voltage Range Option -0 Std.*** -1 -9 -2 Nominal 69 V 120 V 240 V 277 V 480 V w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element *** Leave "Input" positions blank in the model number. Table 5 Scaling Resistor (-RS)/Frequency Options Description Scaling Resistor 400 Hz 50 Hz (not UL Recognized) 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor † You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 6 Other Options * 11/2- and 21/2-element units require a balanced voltage. Option -20 -C2 -C4 Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A Option -RS† -6 -12 -6-RS† -12-RS† Table 1 Base Model Number Selection Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars Table 4 Input Selection Exceltronic -5 If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. P-Option PAN6 PAN7 Output Range 1-5 mAdc 4-20 mAdc Compliance Voltage/ Maximum Load 20 Vdc/4000 Ω 20 Vdc/1000 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc PAN6-B PAN7-B 1-3-5 mAdc 4-12-20 mAdc 20 Vdc/4000 Ω 20 Vdc/1000 Ω 30 Vdc 30 Vdc -CE -SC†† -SM -UB -Z Description †† You must specify the desired input value: 50-200% Calibration Adjustment (current outputs) 0 to ±1 mAdc units can be calibrated within 90-180% of their standardComplete Isolation Between Watt & Var Analog Outputs calibration input watts or vars. (Example: A 2-element watt/var trans(for units with external auxiliary power—requires a ducer is calibrated to 1000 W or vars standard. The -SC option can be added for input levels from 900 W or vars (90%) to 1800 W or vars Style I case; see page 122 for case dimensions) (180%).) P-Option units can be calibrated within 60-180% of their Complete Isolation Between Watt & Var Analog Outputs standard-calibration input watts or vars. (for units with internal auxiliary power—requires a This information is not part of the model number, but must be provided Style I case; see page 122 for case dimensions) to the factory when you place your order. Analog Output Shorting Relay (available only with 0 to ±1 mAdc units) Special Calibration If you require additional options not shown here, see Special Seismic Brace (available with 0 to ±1 mAdc units) Options on page 128. When ordering any special options, or (consult factory if you desire this option with more than three options, you must first consult the factory for a P-Option unit) pricing and delivery estimates. Combination Unidirectional (watt)/Bidirectional (var) (available only with P-Option units) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option unidirectional units) AMETEK® Power Instruments 50 SCI Transducer Cat. 1-51(MTD) Burden ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) P-Option outputs Element 1 11/2* 2 21/2* 3 Frequency Range A2 XLWV342K5 EXAMPLES: Input Range (0 to ±1 mAdc Units) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 51 50-51 1/9/02, 5:26 PM Ordering Procedure Exceltronic Combined AC Watt/Var Transducers Ordering Procedure Exceltronic Combined AC Watt/Var Transducers Table 3 Auxiliary Power Supply Selection ORDERING PROCEDURE Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Description Base Model No. Output Auxiliary Power Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 Ext. Aux. Power A2** A4 Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 6 Table 6 Table 3 (P-Option Units) A2** (leave blank) A4 0 to ±1 mAdc output External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 85-135 Vac 50-500 Hz 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA -1 -RS Specify output voltage A4 PAN7 -SM -SC Specify input value DC external auxiliary power available; see Special Options on page 128. If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. XLWV342K5A2-5-1-RS-SM-SC 3-element, 0 to ±1 mAdc Watt/Var Transducer; 120 Vac external auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). XLWV342K5PAN7A4-5-1-RS-SM-SC 3-element, 4-20 mAdc Watt/Var Transducer; internal auxiliary power; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Watt/Var Model No. XLWV5C5 XLWVW5C511/2 XLWV31K5 XLWV31K521/2 XLWV342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Current Output Option -3 -4 Std.*** -11 -5 -7 (5 A Nominal Input) 100 W or Vars/Element 250 W or Vars/Element 500 W or Vars/Element 750 W or Vars/Element 1000 W or Vars/Element 1500 W or Vars/Element Option -0 Std.*** -1 -9 -2 Nominal 69 V 120 V 240 V 277 V 480 V w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element Description Scaling Resistor 400 Hz 50 Hz (not UL Recognized) 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor † You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc. Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. Table 6 Other Options * 11/2- and 21/2-element units require a balanced voltage. Output Range 1-5 mAdc 4-20 mAdc Compliance Voltage/ Maximum Load 20 Vdc/4000 Ω 20 Vdc/1000 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc PAN6-B PAN7-B 1-3-5 mAdc 4-12-20 mAdc 20 Vdc/4000 Ω 20 Vdc/1000 Ω 30 Vdc 30 Vdc Option -20 -C2 -CE -SC†† -SM -UB -Z Rochester, New York 14605 w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A Voltage Range This information is not part of the model number, but must be provided to the factory when you place your order. P-Option PAN6 PAN7 255 North Union Street Calibration at Rated Output *** Leave "Input" positions blank in the model number. -C4 AMETEK® Power Instruments Voltage Current Range Table 5 Scaling Resistor (-RS)/Frequency Options Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A Option -RS† -6 -12 -6-RS† -12-RS† Table 1 Base Model Number Selection Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars Table 4 Input Selection Exceltronic -5 If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. Phone: 1-800-274-5368 Description †† You must specify the desired input value: 50-200% Calibration Adjustment (current outputs) 0 to ±1 mAdc units can be calibrated within 90-180% of their standardComplete Isolation Between Watt & Var Analog Outputs calibration input watts or vars. (Example: A 2-element watt/var trans(for units with external auxiliary power—requires a ducer is calibrated to 1000 W or vars standard. The -SC option can be added for input levels from 900 W or vars (90%) to 1800 W or vars Style I case; see page 122 for case dimensions) (180%).) P-Option units can be calibrated within 60-180% of their Complete Isolation Between Watt & Var Analog Outputs standard-calibration input watts or vars. (for units with internal auxiliary power—requires a This information is not part of the model number, but must be provided Style I case; see page 122 for case dimensions) to the factory when you place your order. Analog Output Shorting Relay (available only with 0 to ±1 mAdc units) Special Calibration If you require additional options not shown here, see Special Seismic Brace (available with 0 to ±1 mAdc units) Options on page 128. When ordering any special options, or (consult factory if you desire this option with more than three options, you must first consult the factory for a P-Option unit) pricing and delivery estimates. Combination Unidirectional (watt)/Bidirectional (var) (available only with P-Option units) Zero-Based Output Calibration (ex.: PAN7-Z = 0-20 mAdc) (available only with P-Option unidirectional units) Fax: 585-454-7805 50 SCI Transducer Cat. 1-51(MTD) Burden ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) P-Option outputs Element 1 11/2* 2 21/2* 3 Frequency Range A2 XLWV342K5 EXAMPLES: Input Range (0 to ±1 mAdc Units) 51 50-51 1/9/02, 5:26 PM Wiring Diagrams Exceltronic Combined AC Watt/Var Transducers Analog Totalizers WIRING DIAGRAMS FOR 0 to ±1 mAdc AND P-OPTION UNITS (Style IV Case) 1 Element, Single Phase, 2 Wire 11/2 Element, Single Phase, 3 Wire LINE L1 L2 DC OUTPUT - DC OUTPUT COM WATT VAR 2 2A L1 LINE N In many applications, the need to sum the output of a series of transducers is necessary to help determine the operation of a total system. Scientific Columbus’ 9100 Series Analog Totalizers meet this requirement. For example, the total watts supplied by six separate watt transducers can be summed (or totalized) to give a total watts value for all six devices. Other quantities that can be measured and summed include vars, current, and voltage. L2 COM WATT VAR - + + 1 9100 SERIES ANALOG TOTALIZERS 4 3 5 + + 6 1 2 3 2A 4 5 6 7 9 8 10 11 12 13 7 9 8 10 11 12 13 u Up to six inputs u Up to three outputs (one analog and two Form-C pulse outputs) u Analog outputs can be a dc voltage (specify ranges from 0–10 Vdc) or a dc current (0–1, 1–5, 4–20, or 10–50 mAdc) u Inputs normally are 0–1 mAdc. Consult factory for other inputs. Exceltronic Each totalizer is custom designed to meet customer requirements. Options include: LOAD NOTE: Bottom terminal strip (7-13) omitted on A4 models. EXTERNAL AUX. POWER EXTERNAL AUX. POWER 11/2 Element, 3 Phase, 3 Wire, Delta LOAD 2 Element, 3 Phase, 3 Wire, Delta L1 DC OUTPUT L1 LINE L2 COM WATT VAR - + + 1 2 2A For more information on Scientific Columbus’ 9100 Series Analog Totalizers, please consult the factory at 1-800-274-5368 (U.S. and Canada). DC OUTPUT L3 COM WATT VAR - LINE L2 L3 3 4 5 + + 1 6 2 2A 3 4 5 6 Typical Totalizer Showing All Options 7 9 8 10 11 7 12 13 21/2 Element, 3 Phase, 4 Wire, Wye L1 LINE L2 L3 2 2A DC OUTPUT N 3 4 5 6 6A L1 2 2A 3 4 5 6 8 9 EXT. AUX. POWER 10 11 12 13 12A 7 8 9 10 output analog input #1 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #2 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #3 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #4 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #5 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #6 N 6A EXT. AUX. POWER 7 LINE L2 L3 + + 1 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER LOAD COM WATT VAR + + 1 12 13 3 Element, 3 Phase, 4 Wire, Wye COM WATT VAR - 11 EXTERNAL AUX. POWER LOAD DC OUTPUT 10 11 12 13 12A LOAD LOAD AMETEK® Power Instruments 52 SCI Transducer Cat. 52-89(MTD) TOTALIZED FORM-C PULSE OUTPUTS (Wh, Varh, Ah, or Vh) TOTALIZED FORM-C PULSE OUTPUTS (Wh, Varh, Ah, or Vh) 120 Vac EXTERNAL AUX. POWER A2 Models: Shown. A4 Models: External aux. power not required. Adjust TOTALIZED ANALOG OUTPUT 9100 SERIES TOTALIZER EXTERNAL AUX. POWER 9 8 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 53 52-53 1/9/02, 5:27 PM Ametek Transducer Comp MTD1 1/9/02 5:11 PM Page 2 Power Measurement You Can Rely On. AMETEK Power Instruments is Our Products Digital Power Measurement Fully programmable digital and analog transducers with built-in communications. pleased to offer you the very finest brand of power measurement instrumentation - Scientific Columbus. SCIENTIFIC COLUMBUS The Scientific Columbus name is renown for quality and dependability in energy meters, electrical transducers and calibration standards. Power mea- Electronic Energy Meters A complete line of electrical metering products that measure power consumption for utilities and industry. surement data that's not accurate is worthless. Consequently, data from instruments who's accuracy fluctuates under differing conditions become just as meaningless - especially if you are making decisions based on these measurements. Our commitment to high- Electrical Transducers Power-measurement transducers are ideal for power panels, switchgear, and plant process control. accuracy, high stability transducers, meters and calibration is unwavering. Digilogic ™ and Exceltronic transducer's ® .01% and 0.2% of reading (not full-scale) accuracy specifications remains the benchmark of the industry. And now our Digital Calibration Standards Laboratory and portable field standards provide high-accuracy calibration for meters and transducers. Transducers set a new standard, allowing one transducer to be configured for many different applications. Further, one transducer can take up to 37 distinct measurements. AMETEK insures that all of the Scientific Columbus line of transducers meet exacting quality standards that insure their accuracy remains constant over Power Instrumentation Measurement devices developed for specific applications to provide electrical isolation, conversion, and alarms. extended periods of times – sometimes even 20 years. For transducers you can count on… count on Scientific Columbus brand transducers from AMETEK! Technical Training Training courses conducted by qualified instructors are available to assist you in getting the highest performance from your products. Ametek Transducer Comp MTD1 1/9/02 5:11 PM Page 2 Power Measurement You Can Rely On. AMETEK Power Instruments is Our Products Digital Power Measurement Fully programmable digital and analog transducers with built-in communications. pleased to offer you the very finest brand of power measurement instrumentation - Scientific Columbus. SCIENTIFIC COLUMBUS The Scientific Columbus name is renown for quality and dependability in energy meters, electrical transducers and calibration standards. Power mea- Electronic Energy Meters A complete line of electrical metering products that measure power consumption for utilities and industry. surement data that's not accurate is worthless. Consequently, data from instruments who's accuracy fluctuates under differing conditions become just as meaningless - especially if you are making decisions based on these measurements. Our commitment to high- Electrical Transducers Power-measurement transducers are ideal for power panels, switchgear, and plant process control. accuracy, high stability transducers, meters and calibration is unwavering. Digilogic ™ and Exceltronic transducer's ® .01% and 0.2% of reading (not full-scale) accuracy specifications remains the benchmark of the industry. And now our Digital Calibration Standards Laboratory and portable field standards provide high-accuracy calibration for meters and transducers. Transducers set a new standard, allowing one transducer to be configured for many different applications. Further, one transducer can take up to 37 distinct measurements. AMETEK insures that all of the Scientific Columbus line of transducers meet exacting quality standards that insure their accuracy remains constant over Power Instrumentation Measurement devices developed for specific applications to provide electrical isolation, conversion, and alarms. extended periods of times – sometimes even 20 years. For transducers you can count on… count on Scientific Columbus brand transducers from AMETEK! Technical Training Training courses conducted by qualified instructors are available to assist you in getting the highest performance from your products. Wiring Diagrams Exceltronic Combined AC Watt/Var Transducers Analog Totalizers WIRING DIAGRAMS FOR 0 to ±1 mAdc AND P-OPTION UNITS (Style IV Case) 1 Element, Single Phase, 2 Wire 11/2 Element, Single Phase, 3 Wire LINE L1 L2 DC OUTPUT - DC OUTPUT COM WATT VAR 2 2A L1 LINE N In many applications, the need to sum the output of a series of transducers is necessary to help determine the operation of a total system. Scientific Columbus’ 9100 Series Analog Totalizers meet this requirement. For example, the total watts supplied by six separate watt transducers can be summed (or totalized) to give a total watts value for all six devices. Other quantities that can be measured and summed include vars, current, and voltage. L2 COM WATT VAR - + + 1 9100 SERIES ANALOG TOTALIZERS 4 3 5 + + 6 1 2 3 2A 4 5 6 7 9 8 10 11 12 13 7 9 8 10 11 12 13 u Up to six inputs u Up to three outputs (one analog and two Form-C pulse outputs) u Analog outputs can be a dc voltage (specify ranges from 0–10 Vdc) or a dc current (0–1, 1–5, 4–20, or 10–50 mAdc) u Inputs normally are 0–1 mAdc. Consult factory for other inputs. Exceltronic Each totalizer is custom designed to meet customer requirements. Options include: LOAD NOTE: Bottom terminal strip (7-13) omitted on A4 models. EXTERNAL AUX. POWER EXTERNAL AUX. POWER 11/2 Element, 3 Phase, 3 Wire, Delta LOAD 2 Element, 3 Phase, 3 Wire, Delta L1 DC OUTPUT L1 LINE L2 COM WATT VAR - + + 1 2 2A For more information on Scientific Columbus’ 9100 Series Analog Totalizers, please consult the factory at 1-800-274-5368 (U.S. and Canada). DC OUTPUT L3 COM WATT VAR - LINE L2 L3 3 4 5 + + 1 6 2 2A 3 4 5 6 Typical Totalizer Showing All Options 7 9 8 10 11 7 12 13 21/2 Element, 3 Phase, 4 Wire, Wye L1 LINE L2 L3 2 2A DC OUTPUT N 3 4 5 6 6A L1 2 2A 3 4 5 6 8 9 EXT. AUX. POWER 10 11 12 13 12A 7 8 9 10 output analog input #1 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #2 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #3 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #4 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #5 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER output analog input #6 N 6A EXT. AUX. POWER 7 LINE L2 L3 + + 1 WATT, VAR, CURRENT, OR VOLTAGE TRANSDUCER LOAD COM WATT VAR + + 1 12 13 3 Element, 3 Phase, 4 Wire, Wye COM WATT VAR - 11 EXTERNAL AUX. POWER LOAD DC OUTPUT 10 11 12 13 12A LOAD LOAD AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 TOTALIZED FORM-C PULSE OUTPUTS (Wh, Varh, Ah, or Vh) Fax: 585-454-7805 52 SCI Transducer Cat. 52-89(MTD) TOTALIZED FORM-C PULSE OUTPUTS (Wh, Varh, Ah, or Vh) 120 Vac EXTERNAL AUX. POWER A2 Models: Shown. A4 Models: External aux. power not required. Adjust TOTALIZED ANALOG OUTPUT 9100 SERIES TOTALIZER EXTERNAL AUX. POWER 9 8 53 52-53 1/9/02, 5:27 PM SCIENTIFIC Exceltronic AC Watt/Watthour or Var/Varhour Transducers COLUMBUS EXCELTRONIC AC WATT/WATTHOUR OR VAR/VARHOUR TRANSDUCERS Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Burden Power Rated Output (RO) = 500 Watts or Vars/Element Applications Features ◆ Accuracy to 0.2% of reading ◆ Analog & digital outputs ◆ Excellent long-term stability ◆ Exceptional reliability ◆ Energy-management systems ◆ Distribution monitoring ◆ Process control ◆ Wide selection of current & voltage input ranges Outputs 0 to ±1 mAdc Watts (Watt/Watthour Transducer) P-Option* Vars (Var/Varhour Transducer) 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A 120 V 0–150 V 200 V 0.03 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±(0.2% Reading + 0.01% RO) ±(0.2% Reading + 0.05% RO) ±(0.2% Reading + 0.02% RO) ±(0.3% Reading + 0.05% RO) at 0–200% RO at 0–200% RO at 0–120% RO at 0–120% RO Accuracy Temperature Effect on Accuracy ± 0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C ◆ 0 to ± 1 mAdc Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C ◆ 1–5 or 1–3–5 mAdc Compliance Voltage ◆ 4–20 or 4–12–20 mAdc 10 Vdc Load 0–10,000 Ω Output Ripple Peak < 0.5% RO 10 Vdc See Table 2 on page 52. See Table 2 on page 52. 0–10,000 Ω < 0.25% RO < 0.25% RO < 0.5% RO ◆ 10–50 or 10–30–50 mAdc Relay Contact Rating (-60XX option) 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. ◆ Relay and solid-state outputs for watthour and varhour functions Relay Contact Life (-60XX option) One billion operations when operated within specifications. Solid-State Output Contact Rating (-62XX option) Response Time 28 Vdc (maximum) VCESAT: 1 Vdc (maximum) at 7 mAdc < 400 ms to 99% < 1 Second to 99% Power Factor Transducer Accuracy Specsmanship Metrology is the science of measurement for determination of conformance to technical requirements. Scientific Columbus is dedicated to this science. Scientific Columbus transducers provide precise measurements which are rated as “Percent-of-Reading-plusPercent-of-RO” devices. What does this mean? Aren’t all accuracy specifications the same? Standard Calibration Adjustments Like any specification, what is defined may not be as important as how it is defined. When a Percent-of-Reading-plus-Percent-of-RO device is used in a measurement, the maximum measurement tolerance is known. However, many devices are specified as “Percent of Full Scale.” Full-scale specifications can result in a measurement tolerance of 3% or greater, when the tolerance is 0.3% from a Scientific Columbus, Percent-of-Reading-plus-Percent-of-RO Transducer. < 1 Second to 99% < 400 ms to 99% Any PF Effect on Accuracy Gain Zero ±0.1% VA (maximum) ±0.15% VA (maximum) ± 1% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) ± 1% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz Frequency Range Stability (per year) ±0.1% RO, Noncumulative Operating Humidity 0–95% Noncondensing 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Surge Withstand Approximate Dimensions (excluding mounting plate) Overrange with Linearity ±0.25% of Span, Noncumulative ± 0.2% RO, Noncumulative Complete (Input/Output/Power/Case) All KYZ outputs are isolated. Isolation Maximum Net Weight 60 Hz ±0.15% of Span, Noncumulative Dielectric Withstand No. 4 lbs., 12 oz. (2.2 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 5 lbs., 2 oz. (2.3 kg) 4 lbs., 14 oz. (2.2 kg) 7.2" W x 5.3" D x 5.8" H 7.0" W x 3.7" D x 5.6" H (183 mm x 135 mm x 147 mm) (178 mm x 94 mm x 142 mm) Style V Case, see page 123 Style I Case, see page 122 500–600 Watts/Element 5 lbs., 4 oz. (2.4 kg) 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. AMETEK® Power Instruments 54 SCI Transducer Cat. 52-89(MTD) 0 to ±1 mAdc Vars (Var/Varhour Transducer) P-Option* Watts (Watt/Watthour Transducer) Exceltronic Exceltronic combined watt/ watthour and var/varhour transducers provide two simultaneous outputs: an analog output directly proportional to instantaneous watts or vars, and a digital (pulse) output (Form-C mercury-wetted relay or solid-state) directly proportional to watthours or varhours. All models are available in either unidirectional or bidirectional configurations. SCIENTIFIC Specifications COLUMBUS 255 North Union Street Rochester, New York 14605 Specifications subject to change without notice. Phone: 1-800-274-5368 Fax: 585-454-7805 55 54-55 1/9/02, 5:27 PM SCIENTIFIC Exceltronic AC Watt/Watthour or Var/Varhour Transducers COLUMBUS EXCELTRONIC AC WATT/WATTHOUR OR VAR/VARHOUR TRANSDUCERS Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Burden Power Rated Output (RO) = 500 Watts or Vars/Element Applications Features ◆ Accuracy to 0.2% of reading ◆ Analog & digital outputs ◆ Excellent long-term stability ◆ Energy-management systems ◆ Distribution monitoring ◆ Process control ◆ Exceptional reliability ◆ Wide selection of current & voltage input ranges Outputs 0 to ±1 mAdc Watts (Watt/Watthour Transducer) 120 V 0–150 V 200 V 0.03 VA (maximum) at 120 V 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±(0.2% Reading + 0.01% RO) ±(0.2% Reading + 0.05% RO) ±(0.2% Reading + 0.02% RO) ±(0.3% Reading + 0.05% RO) at 0–200% RO at 0–200% RO at 0–120% RO at 0–120% RO Accuracy Temperature Effect on Accuracy ± 0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C ◆ 0 to ± 1 mAdc Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C ◆ 1–5 or 1–3–5 mAdc Compliance Voltage ◆ 4–20 or 4–12–20 mAdc 10 Vdc Load 0–10,000 Ω Output Ripple Peak < 0.5% RO < 0.25% RO < 0.25% RO < 0.5% RO 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. ◆ Relay and solid-state outputs for watthour and varhour functions Relay Contact Life (-60XX option) One billion operations when operated within specifications. Solid-State Output Contact Rating (-62XX option) Response Time 28 Vdc (maximum) VCESAT: 1 Vdc (maximum) at 7 mAdc < 400 ms to 99% < 1 Second to 99% Standard Calibration Adjustments Gain Zero ±0.1% VA (maximum) ±0.15% VA (maximum) ± 1% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) ± 1% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz Frequency Range Stability (per year) ±0.1% RO, Noncumulative Operating Humidity 0–95% Noncondensing 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Surge Withstand Like any specification, what is defined may not be as important as how it is defined. When a Percent-of-Reading-plus-Percent-of-RO device is used in a measurement, the maximum measurement tolerance is known. However, many devices are specified as “Percent of Full Scale.” Full-scale specifications can result in a measurement tolerance of 3% or greater, when the tolerance is 0.3% from a Scientific Columbus, Percent-of-Reading-plus-Percent-of-RO Transducer. Phone: 1-800-274-5368 Approximate Dimensions (excluding mounting plate) Overrange with Linearity ±0.25% of Span, Noncumulative ± 0.2% RO, Noncumulative Complete (Input/Output/Power/Case) All KYZ outputs are isolated. Isolation Maximum Net Weight 60 Hz ±0.15% of Span, Noncumulative Dielectric Withstand No. < 1 Second to 99% < 400 ms to 99% Any PF Effect on Accuracy What does this mean? Aren’t all accuracy specifications the same? 4 lbs., 12 oz. (2.2 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 500–1000 Watts/Element 5 lbs., 2 oz. (2.3 kg) 4 lbs., 14 oz. (2.2 kg) 7.2" W x 5.3" D x 5.8" H 7.0" W x 3.7" D x 5.6" H (183 mm x 135 mm x 147 mm) (178 mm x 94 mm x 142 mm) Style V Case, see page 123 Style I Case, see page 122 500–600 Watts/Element 500–1000 Vars/Element 5 lbs., 4 oz. (2.4 kg) 7.2" W x 5.3" D x 5.8" H (183 mm x 135 mm x 147 mm) Style V Case, see page 123 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. Specifications subject to change without notice. Fax: 585-454-7805 54 SCI Transducer Cat. 52-89(MTD) See Table 2 on page 52. 0–10,000 Ω Relay Contact Rating (-60XX option) Metrology is the science of measurement for determination of conformance to technical requirements. Scientific Columbus is dedicated to this science. Scientific Columbus transducers provide precise measurements which are rated as “Percent-of-Reading-plusPercent-of-RO” devices. Rochester, New York 14605 10 Vdc See Table 2 on page 52. ◆ 10–50 or 10–30–50 mAdc Transducer Accuracy Specsmanship 255 North Union Street P-Option* Vars (Var/Varhour Transducer) 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A Power Factor AMETEK® Power Instruments 0 to ±1 mAdc Vars (Var/Varhour Transducer) P-Option* Watts (Watt/Watthour Transducer) Exceltronic Exceltronic combined watt/ watthour and var/varhour transducers provide two simultaneous outputs: an analog output directly proportional to instantaneous watts or vars, and a digital (pulse) output (Form-C mercury-wetted relay or solid-state) directly proportional to watthours or varhours. All models are available in either unidirectional or bidirectional configurations. SCIENTIFIC Specifications COLUMBUS 55 54-55 1/9/02, 5:27 PM Ordering Procedure Exceltronic AC Watt/Watthour or Var/Varhour Transducers Ordering Procedure Exceltronic AC Watt/Watthour or Var/Varhour Transducers Table 3 Auxiliary Power Supply Selection ORDERING PROCEDURE Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Description Base Model No. Output Auxiliary Power Pulse Output Mounting Orientation Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 Ext. Aux. Power A2*** A4 Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 5 Table 6 Table 7 Table 7 Table 3 (P-Option Units) A2*** (leave blank) 0 to ±1 mAdc output A4 A2 -6070 A4 -V -5 Specify counts per hour -1 -RS -SM Specify output voltage If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. External Auxiliary Power (120 Vac std.) 85-135 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) 100-130 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA -SC DC external auxiliary power available; see Special Options on page 128. Table 4 Pulse Output Selection Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Option -6070 -6270 -6096 -6296 Description Form-C Mercury-Wetted Relay, Unidirectional Form-C Solid-State, Unidirectional Form-C Mercury-Wetted Relay, Bidirectional Form-C Solid-State, Bidirectional XLV31K521/2A2-6070-V-5-1-RS-SM-SC 21/2-element, 0 to ±1 mAdc Var/Varhour Transducer; 120 Vac external auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). XLV31K521/2PAN7A4-6070-V-5-1-RS-SM-SC 21/2-element, 4-20 mAdc Var/Varhour Transducer; internal auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Table 1 Base Model Number Selection Element 1 2 21/2* 3 Watt Model No. XL5C5 XL31K5 XL31K521/2 XL342K5 Var Model No. XLV5C5 XLV31K5 XLV31K521/2 XLV342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. ** PAN and PA models take -6070 or -6270 unidirectional pulse outputs; PAN-B and PA-B models take -6096 or -6296 bidirectional pulse outputs. P-Option** PAN6 PAN7 PAN8 PAN6-B PAN7-B PAN8-B PA6 PA7 PA8 PA6-B PA7-B PA8-B Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Current Option -3 -4 Std.† -11 -5 -7 -8†† Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A 25 A Current Range w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A 0-30 A Option -RS††† -6 -12 -6-RS††† -12-RS††† Voltage Calibration at Rated Output (5 A Nominal Input) Option 100 W or Vars/Element -0 250 W or Vars/Element Std.† 500 W or Vars/Element -1 750 W or Vars/Element -9 1000 W or Vars/Element -2 1500 W or Vars/Element 2500 W or Vars/Element Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element † Leave "Input" positions blank in the model number. †† Option -8 requires a Style V case. (See page 123 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) ††† You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 7 Other Options Option -20 -21 -24 -CE -SC†††† -SM -Z Description †††† You must specify the desired input value: 50-200% Calibration Adjustment (current outputs) 0 to ±1 mAdc units can be calibrated within 90-180% of their standard-calibration input watts or vars. (Example: A 2-element 50-200% Calibration Adjustment (voltage outputs) watt/watthour transducer is calibrated to 1000 W standard. The (available only with 0 to ±1 mAdc units) -SC option can be added for input levels from 900 W (90%) to 1800 W 24 Vdc Loop-Powered (PA7 and PA7-B models only) (180%).) P-Option units can be calibrated within 60-180% of their (consult factory for specifications) standard-calibration input watts or vars. Analog Output Shorting Relay This information is not part of the model number, but must be (available only with 0 to ±1 mAdc units) provided to the factory when you place your order. Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) If you require additional options not shown here, see Special (consult factory if you desire this option with Options on page 128. When ordering any special options, or a P-Option unit) more than three options, you must first consult the factory for Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) pricing and delivery estimates. (available only with P-Option units, except PAN-B models) AMETEK® Power Instruments 56 SCI Transducer Cat. 52-89(MTD) Mounting Orientation***** -V (Vertical) or -H (Horizontal) Not Applicable -V (Vertical) or -H (Horizontal) Not Applicable ***** You must specify the desired mounting orientation for units with mercury-wetted relays. Table 6 Scaling Resistor (-RS)/Frequency Options * 21/2-element units require a balanced voltage. CPH Range**** 2-14,000 2-900,000 2-14,000 2-900,000 *** Standard cph is one count/watthour or varhour unless otherwise specified. Table 5 Input Selection EXAMPLES: Burden Exceltronic PAN7 Frequency Range *** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) XLV31K521/2 P-Option outputs Input Range (0 to ±1 mAdc Units) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 57 56-57 1/9/02, 5:27 PM Ordering Procedure Exceltronic AC Watt/Watthour or Var/Varhour Transducers Ordering Procedure Exceltronic AC Watt/Watthour or Var/Varhour Transducers Table 3 Auxiliary Power Supply Selection ORDERING PROCEDURE Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Description Base Model No. Output Auxiliary Power Pulse Output Mounting Orientation Current Input Voltage Input -RS/Freq. Option #1 Option #2 Option #3 Ext. Aux. Power A2*** A4 Table 1 Table 2 Table 3 Table 4 Table 4 Table 5 Table 5 Table 6 Table 7 Table 7 Table 3 (P-Option Units) A2*** (leave blank) 0 to ±1 mAdc output A4 A2 -6070 A4 -V -5 Specify counts per hour -1 -RS -SM Specify output voltage If A2 is selected, leave this space blank; specify ext. aux. power voltage at end of model no. External Auxiliary Power (120 Vac std.) 85-135 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 70-112% of Nominal Aux. Power Voltage Equals Input Frequency 3 VA 3 VA External Auxiliary Power (120 Vac std.) 100-130 Vac 50-500 Hz Internal Auxiliary Power (self-powered) 84-108% of Nominal Aux. Power Voltage Equals Input Frequency 6 VA 6 VA -SC DC external auxiliary power available; see Special Options on page 128. Table 4 Pulse Output Selection Specify input value If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Option -6070 -6270 -6096 -6296 Description Form-C Mercury-Wetted Relay, Unidirectional Form-C Solid-State, Unidirectional Form-C Mercury-Wetted Relay, Bidirectional Form-C Solid-State, Bidirectional XLV31K521/2A2-6070-V-5-1-RS-SM-SC 21/2-element, 0 to ±1 mAdc Var/Varhour Transducer; 120 Vac external auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). XLV31K521/2PAN7A4-6070-V-5-1-RS-SM-SC 21/2-element, 4-20 mAdc Var/Varhour Transducer; internal auxiliary power; mercury-wetted relay (unidirectional); vertical mounting; 10 A input; 240 V input; resistor scaling (converts current output to voltage output); seismic brace; special calibration (example: 7200 W). Table 1 Base Model Number Selection Element 1 2 21/2* 3 Watt Model No. XL5C5 XL31K5 XL31K521/2 XL342K5 Var Model No. XLV5C5 XLV31K5 XLV31K521/2 XLV342K5 Connection Single Phase 3 Phase, 3 Wire 3 Phase, 4 Wire 3 Phase, 4 Wire Calibration at Rated Output (5 A, 120 V Nominal Input) 500 W or Vars 1000 W or Vars 1500 W or Vars 1500 W or Vars Table 2 Output Selection 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. P-Option** PAN6 PAN7 PAN8 PAN6-B PAN7-B PAN8-B PA6 PA7 PA8 ** PAN and PA models take -6070 or -6270 unidirectional pulse outputs; PAN-B and PA-B models take -6096 or -6296 bidirectional pulse outputs. PA6-B PA7-B PA8-B AMETEK® Power Instruments 255 North Union Street Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Rochester, New York 14605 Phone: 1-800-274-5368 Current Option -3 -4 Std.† -11 -5 -7 -8†† Nominal 1A 2.5 A 5A 7.5 A 10 A 15 A 25 A Option -RS††† -6 -12 -6-RS††† -12-RS††† Current Range w/ Accuracy 0-2 A 0-5 A 0-10 A 0-15 A 0-20 A 0-20 A 0-30 A Voltage Calibration at Rated Output (5 A Nominal Input) Option 100 W or Vars/Element -0 250 W or Vars/Element Std.† 500 W or Vars/Element -1 750 W or Vars/Element -9 1000 W or Vars/Element -2 1500 W or Vars/Element 2500 W or Vars/Element Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor Nominal 69 V 120 V 240 V 277 V 480 V Voltage Range w/ Accuracy 0-75 V 0-150 V 0-300 V 0-340 V 0-600 V Calibration at Rated Output (120 V Nominal Input) 250 W or Vars/Element 500 W or Vars/Element 1000 W or Vars/Element 1200 W or Vars/Element 2000 W or Vars/Element † Leave "Input" positions blank in the model number. †† Option -8 requires a Style V case. (See page 123 for case dimensions. Maximum height of terminal strip(s) is 1.07" for units with -8 option.) ††† You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 7 Other Options Option -20 -21 -24 -CE -SC†††† -SM -Z Description †††† You must specify the desired input value: 50-200% Calibration Adjustment (current outputs) 0 to ±1 mAdc units can be calibrated within 90-180% of their standard-calibration input watts or vars. (Example: A 2-element 50-200% Calibration Adjustment (voltage outputs) watt/watthour transducer is calibrated to 1000 W standard. The (available only with 0 to ±1 mAdc units) -SC option can be added for input levels from 900 W (90%) to 1800 W 24 Vdc Loop-Powered (PA7 and PA7-B models only) (180%).) P-Option units can be calibrated within 60-180% of their (consult factory for specifications) standard-calibration input watts or vars. Analog Output Shorting Relay This information is not part of the model number, but must be (available only with 0 to ±1 mAdc units) provided to the factory when you place your order. Special Calibration Seismic Brace (available with 0 to ±1 mAdc units) If you require additional options not shown here, see Special (consult factory if you desire this option with Options on page 128. When ordering any special options, or a P-Option unit) more than three options, you must first consult the factory for Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) pricing and delivery estimates. (available only with P-Option units, except PAN-B models) Fax: 585-454-7805 56 SCI Transducer Cat. 52-89(MTD) Mounting Orientation***** -V (Vertical) or -H (Horizontal) Not Applicable -V (Vertical) or -H (Horizontal) Not Applicable ***** You must specify the desired mounting orientation for units with mercury-wetted relays. Table 6 Scaling Resistor (-RS)/Frequency Options * 21/2-element units require a balanced voltage. CPH Range**** 2-14,000 2-900,000 2-14,000 2-900,000 *** Standard cph is one count/watthour or varhour unless otherwise specified. Table 5 Input Selection EXAMPLES: Burden Exceltronic PAN7 Frequency Range *** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) XLV31K521/2 P-Option outputs Input Range (0 to ±1 mAdc Units) 57 56-57 1/9/02, 5:27 PM Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) 21/2 Element, 3 Phase, 4 Wire, Wye 1 Element, Single Phase, 2 Wire 1 - + 2 3 4 5 6 A B C D DC OUTPUT 1 L1 L2 - + 2 3 4 5 6 A B C DC OUTPUT 1 D L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G 7 H LOAD 8 9 10 11 12 E F G L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 L2 Exceltronic - L1 L2 LINE LINE LINE LINE L1 DC OUTPUT -6270/-6296 Models -6070/-6096 Models -6270/-6296 Models -6070/-6096 Models 7 H 8 9 10 11 12 E F G H LOAD EXTERNAL AUX. POWER EXTERNAL AUX. POWER LOAD LOAD Omitted on -6070 Models Omitted on -6070 Models Omitted on -6270 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 3 Element, 3 Phase, 4 Wire, Wye 2 Element, 3 Phase, 3 Wire, Delta -6070/-6096 Models L1 - DC OUTPUT 1 2 LINE L2 L1 L3 - + 3 4 5 6 A B C -6070/-6096 Models -6270/-6296 Models DC OUTPUT 1 D 2 LINE L2 -6270/-6296 Models LINE L3 L1 L2 LINE L3 L1 N + 3 4 5 6 A B C - D DC OUTPUT - + 1 2 3 4 5 6 A B C D DC OUTPUT + 1 2 3 4 5 6 A B C D EXTERNAL AUX. POWER 7 8 9 10 11 12 E F G 7 H 8 9 10 11 12 E F G LOAD Omitted on -6070 Models EXTERNAL AUX. POWER H 7 EXTERNAL AUX. POWER EXTERNAL AUX. POWER 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models Adjust A2 Models: Shown. A4 Models: External aux. power not required. Adjust AMETEK® Power Instruments 58 SCI Transducer Cat. 52-89(MTD) L2 LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 59 58-59 1/9/02, 5:27 PM Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style I Case) 21/2 Element, 3 Phase, 4 Wire, Wye 1 Element, Single Phase, 2 Wire 1 - + 2 3 4 5 6 A B C D DC OUTPUT 1 L1 L2 - + 2 3 4 5 6 A B C DC OUTPUT 1 D L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G 7 H LOAD 8 9 10 11 12 E F G L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 L2 Exceltronic - L1 L2 LINE LINE LINE LINE L1 DC OUTPUT -6270/-6296 Models -6070/-6096 Models -6270/-6296 Models -6070/-6096 Models 7 H 8 9 10 11 12 E F G H LOAD EXTERNAL AUX. POWER EXTERNAL AUX. POWER LOAD LOAD Omitted on -6070 Models Omitted on -6070 Models Omitted on -6270 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 3 Element, 3 Phase, 4 Wire, Wye 2 Element, 3 Phase, 3 Wire, Delta -6070/-6096 Models L1 - DC OUTPUT 1 2 LINE L2 L1 L3 - + 3 4 5 6 A B C -6070/-6096 Models -6270/-6296 Models DC OUTPUT 1 D 2 LINE L2 -6270/-6296 Models LINE L3 L1 L2 LINE L3 L1 N + 3 4 5 6 A B C - D DC OUTPUT - + 1 2 3 4 5 6 A B C D DC OUTPUT + 1 2 3 4 5 6 A B C D EXTERNAL AUX. POWER 7 8 9 10 11 12 E F G 7 H 8 9 10 11 12 E F G LOAD EXTERNAL AUX. POWER Omitted on -6070 Models EXTERNAL AUX. POWER H 7 EXTERNAL AUX. POWER 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models Adjust Adjust A2 Models: Shown. A4 Models: External aux. power not required. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. Fax: 585-454-7805 58 SCI Transducer Cat. 52-89(MTD) L2 59 58-59 1/9/02, 5:27 PM Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) 1 Element, Single Phase, 2 Wire 21/2 Element, 3 Phase, 4 Wire, Wye -6270/-6296 Models -6070/-6096 Models - DC OUTPUT L1 - + 2 3 4 5 6 A B C D DC OUTPUT 1 L1 L2 - + 2 3 4 5 6 A B C LINE LINE LINE L2 DC OUTPUT 1 D L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 LOAD 8 9 EXTERNAL AUX. POWER 10 11 12 E F G H 7 LOAD 8 9 10 11 12 E F G L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 L2 Exceltronic 1 -6270/-6296 Models -6070/-6096 Models LINE L1 H 7 8 9 10 11 12 E F G H EXTERNAL AUX. POWER LOAD LOAD Omitted on -6070 Models Omitted on -6270 Models Omitted on -6070 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070/-6096 Models -6270/-6296 Models L1 LINE L2 -6070/-6096 Models L1 L3 LINE L2 -6270/-6296 Models L3 LINE L1 - DC OUTPUT - + DC OUTPUT 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT + 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G 2 LOAD Omitted on -6070 Models L1 - 3 4 5 6 A B C D + EXTERNAL AUX. POWER 1 2 3 4 5 6 A B C D 8 9 10 11 12 E F G EXTERNAL AUX. POWER 7 H 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models Adjust A2 Models: Shown. A4 Models: External aux. power not required. Adjust AMETEK® Power Instruments 60 SCI Transducer Cat. 52-89(MTD) L2 DC OUTPUT EXTERNAL AUX. POWER H 7 EXTERNAL AUX. POWER N D 1 7 L3 + 1 LINE L2 LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 61 60-61 1/9/02, 5:27 PM Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers Wiring Diagrams Exceltronic AC Watt/Watthour or Var/Varhour Transducers WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) WIRING DIAGRAMS FOR P-OPTION UNITS (Style V Case) 1 Element, Single Phase, 2 Wire 21/2 Element, 3 Phase, 4 Wire, Wye -6270/-6296 Models -6070/-6096 Models - DC OUTPUT L1 - + 2 3 4 5 6 A B C D DC OUTPUT 1 L1 L2 - + 2 3 4 5 6 A B C LINE LINE LINE L2 DC OUTPUT 1 D L2 L3 - + 2 L1 N 3 4 5 6 A B C DC OUTPUT 1 D 8 9 10 11 12 E F G H 7 LOAD 8 9 EXTERNAL AUX. POWER 10 11 12 E F G H 7 LOAD 8 9 10 11 12 E F G L3 N L3 N + 2 3 4 5 6 A B C D EXTERNAL AUX. POWER EXTERNAL AUX. POWER 7 L2 Exceltronic 1 -6270/-6296 Models -6070/-6096 Models LINE L1 H 7 8 9 10 11 12 E F G H EXTERNAL AUX. POWER LOAD LOAD Omitted on -6070 Models Omitted on -6270 Models Omitted on -6070 Models Omitted on -6270 Models NOTE: For 1-element units with -8 option, connect current input to terminals 7 (•) & 10. 2 Element, 3 Phase, 3 Wire, Delta 3 Element, 3 Phase, 4 Wire, Wye -6070/-6096 Models -6270/-6296 Models L1 LINE L2 -6070/-6096 Models L1 L3 LINE L2 -6270/-6296 Models L3 LINE L1 - DC OUTPUT - + DC OUTPUT 2 3 4 5 6 A B C D 1 2 3 4 5 6 A B C DC OUTPUT + 8 9 10 11 12 E F G H 7 8 9 10 11 12 E F G 2 LOAD L1 3 4 5 6 A B C D + 1 2 3 4 5 6 A B C D 8 9 10 11 12 E F G EXTERNAL AUX. POWER 7 H 8 9 10 11 12 E F G H LOAD Omitted on -6270 Models LOAD Omitted on -6070 Models Adjust Adjust A2 Models: Shown. A4 Models: External aux. power not required. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 LOAD Omitted on -6270 Models A2 Models: Shown. A4 Models: External aux. power not required. Fax: 585-454-7805 60 SCI Transducer Cat. 52-89(MTD) L2 DC OUTPUT EXTERNAL AUX. POWER EXTERNAL AUX. POWER Omitted on -6070 Models - H 7 EXTERNAL AUX. POWER N D 1 7 LINE L3 + 1 L2 61 60-61 1/9/02, 5:27 PM SCIENTIFIC Exceltronic AC Phase Angle (Power Factor) Transducers COLUMBUS Scientific Columbus offers a wide selection of phase angle trans-ducers that can be used to determine power factor. The transducers produce a dc output which is linearly proportional to the phase angle difference between the voltage and current in an ac power system. The power factor is equal to the cosine of the phase angle. Therefore, a conversion is required if the linear phase angle output is to be converted to power factor. (See Conversion Table on page 62.) SCIENTIFIC Specifications COLUMBUS EXCELTRONIC PHASE ANGLE (POWER FACTOR) TRANSDUCERS Specifications Current Input Voltage Input Nominal Range Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0.25–5 A 10 A 250 A 1 VA (maximum) at 5 A Nominal Range Overload Continuous Burden/Element PF-1, -2, -3 Models 120 V 95–135 V 150 V 5.5 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Type A & A1 Units Type A4 Units 100–130 Vac 50–500 Hz 3 VA Nominal ± 50 mVdc for Standard Calibration ±0.5 mAdc for Standard Calibration 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* Accuracy See table below. Operating Temperature Range Applications Outputs See table below. ◆ Bipolar output ◆ Generating stations ◆ 0 to ± 50 mVdc ◆ Exceptional reliability ◆ Process control ◆ 0 to ± 0.5 mAdc ◆ High accuracy ◆ Energy-management systems ◆ 1–3–5 mAdc -20° C to +60° C Compliance Voltage 5 Vdc for Type A4 Units Load See Table 1 on page 60. Output Ripple Peak Type A Units Type A1 & A4 Units Response Type A Units Time Type A1 & A4 Units Gain Zero ◆ 10–30–50 mAdc Frequency PF-1, -2, -3 Models Range PF-34 Models < 0.25% of Span < 10 ms to 99% < 400 ms to 99% < 1 Second to 99% ±10% of Reading (minimum) ±2% of RO (minimum) ±20% of Span (minimum) ±5% of Zero Point (minimum) Nominal ± 0.25% Nominal ±5% Stability (per year) ±1% of Span, Noncumulative Operating Humidity 0–95% Noncondensing Isolation 1500 VRMS at 60 Hz Surge Withstand Maximum Net Weight Approximate Dimensions (excluding mounting plate) Complete (Input/Output/Power/Case) Complete (Input/Output/Case) Dielectric Withstand ANSI/IEEE C37.90.1 2 lbs., 12 oz. (1.2 kg) 4 lbs., 2 oz. (1.9 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 *P-Option includes 1–3–5, 4–12–20, and 10–30–50 mAdc outputs. Specifications subject to change without notice. Model No./Accuracy 25 ° C PF-1A, PF-1A1, PF-1A4 ±0.01 PF from 0.8 Lead to 0.8 Lag ± 0.03 PF from 0.3 Lead to 0.3 Lag PF-2A, PF-2A1, PF-2A4 ±0.01 PF from 0.8 Lead to 0.8 Lag ±0.025 PF from 0.5 Lead to 0.5 Lag PF-3A, PF-3A1, PF-3A4 ±0.01 PF from 0.9 Lead to 0.9 Lag ± 0.02 PF from 0.7 Lead to 0.7 Lag PF-34A, PF-34A1, PF-34A4 ±0.01 PF from 0.8 Lead to 0.8 Lag ±0.025 PF from 0.5 Lead to 0.5 Lag AMETEK® Power Instruments 62 SCI Transducer Cat. 52-89(MTD) See Table 2 on page 61. See Table 1 on page 60. Standard Calibration Adjustments When utility rate tariffs are predicated on power factor, a Scientific Columbus Exceltronic Phase Angle (Power Factor) Transducer can be employed to help establish set points or targets. By installing a Scientific Columbus Exceltronic Phase Angle (Power Factor) Transducer and a Scientific Columbus Signal Conditioner together, a target can be set to give indication or alarm when a specific value is achieved. -20° C to +50° C 200 mV Peak to Peak < 1% RMS Power Factor ◆ 4–12–20 mAdc Utility Rate Tariffs and Power Factor PF-34 Models 120 V/220 V 95–135 V/190–250 V 150 V/275 V 5.5 VA (maximum) at 120 V None Required Temperature Effect on Accuracy Features P-Option* (Phase Angle (Power Factor) Transducer) Exceltronic All models have bipolar output; therefore indicating not only the phase angle but also whether it is lead or lag. The transducers provide a meaningful indication of phase angle on a three-phase system, only when balanced load conditions prevail. While all models may be used on three-phase, four-wire systems, only the PF-34 models can be used on three-phase, three-wire systems. The PF-34 models are recommended if varying line frequency is present. 0 to ±50 mVdc or 0 to ±0.5 mAdc (Phase Angle (Power Factor) Transducer) 255 North Union Street - 20° C to + 60 ° C (- 25 ° C to + 50 ° C for P-Option Units) PF-1 ±0.02 PF from 0.8 Lead to 0.8 Lag ±0.05 PF from 0.3 Lead to 0.3 Lag PF-2 ±0.02 PF from 0.8 Lead to 0.8 Lag ±0.04 PF from 0.5 Lead to 0.5 Lag PF-3 ±0.015 PF from 0.9 Lead to 0.9 Lag ±0.03 PF from 0.7 Lead to 0.7 Lag PF-34 ±0.02 PF from 0.8 Lead to 0.8 Lag ±0.04 PF from 0.5 Lead to 0.5 Lag Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 63 62-63 1/9/02, 5:28 PM SCIENTIFIC Exceltronic AC Phase Angle (Power Factor) Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC PHASE ANGLE (POWER FACTOR) TRANSDUCERS Scientific Columbus offers a wide selection of phase angle trans-ducers that can be used to determine power factor. The transducers produce a dc output which is linearly proportional to the phase angle difference between the voltage and current in an ac power system. The power factor is equal to the cosine of the phase angle. Therefore, a conversion is required if the linear phase angle output is to be converted to power factor. (See Conversion Table on page 62.) Specifications Current Input Voltage Input Nominal Range Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0.25–5 A 10 A 250 A 1 VA (maximum) at 5 A Nominal Range Overload Continuous Burden/Element PF-1, -2, -3 Models 120 V 95–135 V 150 V 5.5 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Type A & A1 Units Type A4 Units 100–130 Vac 50–500 Hz 3 VA Nominal ± 50 mVdc for Standard Calibration ±0.5 mAdc for Standard Calibration 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* Accuracy See table below. Operating Temperature Range Applications Outputs See table below. ◆ Bipolar output ◆ Generating stations ◆ 0 to ± 50 mVdc ◆ Exceptional reliability ◆ Process control ◆ 0 to ± 0.5 mAdc ◆ High accuracy ◆ Energy-management systems ◆ 1–3–5 mAdc -20° C to +60° C Compliance Voltage 5 Vdc for Type A4 Units Load See Table 1 on page 60. Output Ripple Peak Type A Units Type A1 & A4 Units Response Type A Units Time Type A1 & A4 Units Standard Calibration Adjustments Gain Zero ◆ 10–30–50 mAdc Frequency PF-1, -2, -3 Models Range PF-34 Models < 0.25% of Span < 10 ms to 99% < 400 ms to 99% < 1 Second to 99% ±10% of Reading (minimum) ±2% of RO (minimum) Nominal ± 0.25% Nominal ±5% ±1% of Span, Noncumulative Operating Humidity 0–95% Noncondensing 1500 VRMS at 60 Hz Surge Withstand Maximum Net Weight Rochester, New York 14605 Phone: 1-800-274-5368 Approximate Dimensions (excluding mounting plate) ANSI/IEEE C37.90.1 2 lbs., 12 oz. (1.2 kg) 4 lbs., 2 oz. (1.9 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 *P-Option includes 1–3–5, 4–12–20, and 10–30–50 mAdc outputs. Specifications subject to change without notice. Model No./Accuracy 25 ° C PF-1A, PF-1A1, PF-1A4 ±0.01 PF from 0.8 Lead to 0.8 Lag ± 0.03 PF from 0.3 Lead to 0.3 Lag PF-2A, PF-2A1, PF-2A4 ±0.01 PF from 0.8 Lead to 0.8 Lag ±0.025 PF from 0.5 Lead to 0.5 Lag PF-3A, PF-3A1, PF-3A4 ±0.01 PF from 0.9 Lead to 0.9 Lag ± 0.02 PF from 0.7 Lead to 0.7 Lag PF-34A, PF-34A1, PF-34A4 ±0.01 PF from 0.8 Lead to 0.8 Lag ±0.025 PF from 0.5 Lead to 0.5 Lag - 20° C to + 60 ° C (- 25 ° C to + 50 ° C for P-Option Units) PF-1 ±0.02 PF from 0.8 Lead to 0.8 Lag ±0.05 PF from 0.3 Lead to 0.3 Lag PF-2 ±0.02 PF from 0.8 Lead to 0.8 Lag ±0.04 PF from 0.5 Lead to 0.5 Lag PF-3 ±0.015 PF from 0.9 Lead to 0.9 Lag ±0.03 PF from 0.7 Lead to 0.7 Lag PF-34 ±0.02 PF from 0.8 Lead to 0.8 Lag ±0.04 PF from 0.5 Lead to 0.5 Lag Fax: 585-454-7805 62 SCI Transducer Cat. 52-89(MTD) Complete (Input/Output/Power/Case) Complete (Input/Output/Case) Dielectric Withstand 255 North Union Street ±20% of Span (minimum) ±5% of Zero Point (minimum) Stability (per year) Isolation AMETEK® Power Instruments See Table 2 on page 61. See Table 1 on page 60. ◆ 4–12–20 mAdc When utility rate tariffs are predicated on power factor, a Scientific Columbus Exceltronic Phase Angle (Power Factor) Transducer can be employed to help establish set points or targets. By installing a Scientific Columbus Exceltronic Phase Angle (Power Factor) Transducer and a Scientific Columbus Signal Conditioner together, a target can be set to give indication or alarm when a specific value is achieved. -20° C to +50° C 200 mV Peak to Peak < 1% RMS Power Factor Utility Rate Tariffs and Power Factor PF-34 Models 120 V/220 V 95–135 V/190–250 V 150 V/275 V 5.5 VA (maximum) at 120 V None Required Temperature Effect on Accuracy Features P-Option* (Phase Angle (Power Factor) Transducer) Exceltronic All models have bipolar output; therefore indicating not only the phase angle but also whether it is lead or lag. The transducers provide a meaningful indication of phase angle on a three-phase system, only when balanced load conditions prevail. While all models may be used on three-phase, four-wire systems, only the PF-34 models can be used on three-phase, three-wire systems. The PF-34 models are recommended if varying line frequency is present. 0 to ±50 mVdc or 0 to ±0.5 mAdc (Phase Angle (Power Factor) Transducer) 63 62-63 1/9/02, 5:28 PM Ordering Procedure Exceltronic AC Phase Angle (Power Factor) Transducers Ordering Procedure Exceltronic AC Phase Angle (Power Factor) Transducers Table 2 Output Selection ORDERING PROCEDURE P-Option PAN6-B PAN7-B PAN8-B Output Range 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc PA6-B PA7-B PA8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Base Model No. Output -RS/Freq. Option #1 Table 1 Table 2 Table 3 0 to ± 50 mVdc or 0 to ± 0.5 mAdc outputs Option #2 Option #3 Table 4 Table 4 External Aux. Power PF-34A4 -RS PF-34 PA7-B -SM Specify output voltage Table 3 Scaling Resistor (-RS)/Frequency Options -24 If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 227 Vac Aux., or 480 Vac Aux. EXAMPLES: PF-34A4-RS-SM 3-phase, 0 to ±0.5 mAdc Phase Angle (PF) Transducer; resistor scaling (converts current output to voltage output); seismic brace. PF-34PA7-B-RS-SM-24 3-phase, 4-12-20 mAdc Phase Angle (PF) Transducer; resistor scaling (converts current output to voltage output); seismic brace; 24 Vdc loop-powered. Output (Linear to Phase Angle) Output Load Required Phase Angle Range Power Factor Range PF-1A PF-1A1 PF-1A4 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±72.5 o 0 to ±72.5 o 0 to ±72.5 o Lead 0.3 to Unity to Lag 0.3 Lead 0.3 to Unity to Lag 0.3 Lead 0.3 to Unity to Lag 0.3 PF-2A PF-2A1 PF-2A4 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±60 o 0 to ±60 o 0 to ±60 o Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 PF-3A PF-3A1 PF-3A4 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±45.5 o 0 to ±45.5 o 0 to ±45.5 o Lead 0.7 to Unity to Lag 0.7 Lead 0.7 to Unity to Lag 0.7 Lead 0.7 to Unity to Lag 0.7 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±60 o 0 to ±60 o 0 to ±60 o Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 See Table 2 See Table 2 See Table 2 See Table 2 See Table 2 See Table 2 0 to ±72.5 o 0 to ±60 o 0 to ±45.5 o Lead 0.3 to Unity to Lag 0.3 Lead 0.5 to Unity to Lag 0.5 Lead 0.7 to Unity to Lag 0.7 See Table 2 See Table 2 0 to ±60 o Lead 0.5 to Unity to Lag 0.5 (0 to ± 50 mVdc or 0 to ± 0.5 mAdc Units) Single Phase or 3 Phase, 4 Wire Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor * You must specify the desired output voltage: For 0 to ±50 mVdc or 0 to ±0.5 mAdc units, specify range from 0 to ±5 Vdc. Load impedance is 2 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 4 Other Options Option -24 Table 1 Base Model Number Selection Model No. Option -RS* -6 -12 -6-RS* -12-RS* Exceltronic P-Option outputs If one of the bidirectional outputs at right is required, indicate the appropriate P-Option in the "Output" position of the complete model number. -SM Description 24 Vdc Loop-Powered (PA7-B models only) (consult factory for specifications) Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. 3 Phase, 3 Wire or 4 Wire PF-34A PF-34A1 PF-34A4 (P-Option Units) Single Phase or 3 Phase, 4 Wire PF-1 PF-2 PF-3 3 Phase, 3 Wire or 4 Wire PF-34 AMETEK® Power Instruments 64 SCI Transducer Cat. 52-89(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 65 64-65 1/9/02, 5:28 PM Ordering Procedure Exceltronic AC Phase Angle (Power Factor) Transducers Ordering Procedure Exceltronic AC Phase Angle (Power Factor) Transducers Table 2 Output Selection ORDERING PROCEDURE P-Option PAN6-B PAN7-B PAN8-B Output Range 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc PA6-B PA7-B PA8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Base Model No. Output -RS/Freq. Option #1 Table 1 Table 2 Table 3 0 to ± 50 mVdc or 0 to ± 0.5 mAdc outputs Option #2 Option #3 Table 4 Table 4 External Aux. Power PF-34A4 -RS PF-34 PA7-B -SM Specify output voltage Table 3 Scaling Resistor (-RS)/Frequency Options -24 If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 227 Vac Aux., or 480 Vac Aux. EXAMPLES: PF-34A4-RS-SM 3-phase, 0 to ±0.5 mAdc Phase Angle (PF) Transducer; resistor scaling (converts current output to voltage output); seismic brace. PF-34PA7-B-RS-SM-24 3-phase, 4-12-20 mAdc Phase Angle (PF) Transducer; resistor scaling (converts current output to voltage output); seismic brace; 24 Vdc loop-powered. Output (Linear to Phase Angle) Output Load Required Phase Angle Range Power Factor Range PF-1A PF-1A1 PF-1A4 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±72.5 o 0 to ±72.5 o 0 to ±72.5 o Lead 0.3 to Unity to Lag 0.3 Lead 0.3 to Unity to Lag 0.3 Lead 0.3 to Unity to Lag 0.3 PF-2A PF-2A1 PF-2A4 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±60 o 0 to ±60 o 0 to ±60 o Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 PF-3A PF-3A1 PF-3A4 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±45.5 o 0 to ±45.5 o 0 to ±45.5 o Lead 0.7 to Unity to Lag 0.7 Lead 0.7 to Unity to Lag 0.7 Lead 0.7 to Unity to Lag 0.7 0 to ±50 mVdc 0 to ±50 mVdc 0 to ±0.5 mAdc 100 Ω ≥50,000 Ω 0-10,000 Ω 0 to ±60 o 0 to ±60 o 0 to ±60 o Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 Lead 0.5 to Unity to Lag 0.5 See Table 2 See Table 2 See Table 2 See Table 2 See Table 2 See Table 2 0 to ±72.5 o 0 to ±60 o 0 to ±45.5 o Lead 0.3 to Unity to Lag 0.3 Lead 0.5 to Unity to Lag 0.5 Lead 0.7 to Unity to Lag 0.7 See Table 2 See Table 2 0 to ±60 o Lead 0.5 to Unity to Lag 0.5 (0 to ± 50 mVdc or 0 to ± 0.5 mAdc Units) Single Phase or 3 Phase, 4 Wire Description Scaling Resistor 400 Hz 50 Hz 400 Hz and Scaling Resistor 50 Hz and Scaling Resistor * You must specify the desired output voltage: For 0 to ±50 mVdc or 0 to ±0.5 mAdc units, specify range from 0 to ±5 Vdc. Load impedance is 2 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 4 Other Options Option -24 Table 1 Base Model Number Selection Model No. Option -RS* -6 -12 -6-RS* -12-RS* Exceltronic P-Option outputs If one of the bidirectional outputs at right is required, indicate the appropriate P-Option in the "Output" position of the complete model number. -SM Description 24 Vdc Loop-Powered (PA7-B models only) (consult factory for specifications) Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. 3 Phase, 3 Wire or 4 Wire PF-34A PF-34A1 PF-34A4 (P-Option Units) Single Phase or 3 Phase, 4 Wire PF-1 PF-2 PF-3 3 Phase, 3 Wire or 4 Wire PF-34 AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 64 SCI Transducer Cat. 52-89(MTD) 65 64-65 1/9/02, 5:28 PM Wiring Diagrams Exceltronic AC Phase Angle (Power Factor) Transducers Conversion Table Exceltronic AC Phase Angle (Power Factor) Transducers CONVERSION TABLE (% Full Scale to Power Factor) WIRING DIAGRAMS FOR 0 to ±50 mVdc AND 0 to ±0.5 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) Percent Full Scale Angle Angle in Decimals 1.000 .995 .990 .985 .980 .975 .970 .965 .960 .955 .950 .940 .930 .920 .910 .900 .890 .880 .870 .860 .850 .840 .830 .820 .810 .800 .790 .780 .770 .760 .750 .740 .730 .720 .710 .700 .680 .660 .640 .620 .600 .580 .560 .540 .520 .500 .480 .460 .440 .420 .400 .380 .360 .340 .320 .300 0°0' 5°44' 8°6.6' 9°56' 11°29' 12°50' 14°4.2' 15°12' 16°16' 17°15' 18°12' 19°57' 21°34' 23°4.4' 24°30' 25°50.5' 27°8' 28°21.5' 29°32.5' 30°41' 31°47' 32°52' 33°54' 34°55' 35°54' 36°52' 37°49' 38°44' 39°39' 40°32' 41°25' 42°16' 43°7' 43°57' 44°46' 45°34' 47°9' 48°42' 50°12.5' 51°41' 53°8' 54°33' 55°57' 57°19' 58°40' 60°0' 61°19' 62°37' 63°54' 65°10' 66°25' 67°40' 68°54' 70°7.4' 71°20.2' 72°32.5' 0.00° 5.73° 8.11° 9.94° 11.48° 12.84° 14.07° 15.20° 16.26° 17.25° 18.19° 19.95° 21.57° 23.07° 24.49° 25.84° 27.13° 28.36° 29.54° 30.68° 31.79° 32.86° 33.90° 34.92° 35.90° 36.87° 37.81° 38.74° 39.65° 40.54° 41.41° 42.27° 43.11° 43.95° 44.77° 45.57° 47.16° 48.70° 50.21° 51.68° 53.13° 54.55° 55.94° 57.32° 58.67° 60.00° 61.31° 62.61° 63.90° 65.17° 66.42° 67.67° 68.90° 70.12° 71.34° 72.54° (45.57°) FS = 0.7 PF 0.00 12.58 17.80 21.80 25.19 28.17 30.87 33.36 35.70 37.86 39.92 43.77 47.32 50.63 53.75 56.70 59.52 62.22 64.82 67.32 69.75 72.10 74.39 76.61 78.78 80.90 82.98 85.01 86.99 88.95 90.86 92.75 94.60 96.43 98.23 100.00 (60°) FS = 0.5 PF 0.00 9.56 13.52 16.56 19.13 21.40 23.45 25.34 27.10 28.76 30.32 33.25 35.94 38.46 40.82 43.07 45.21 47.26 49.24 51.14 52.98 54.77 56.50 58.19 59.84 61.45 63.02 64.57 66.08 67.56 69.02 70.45 71.86 73.24 74.61 75.95 78.59 81.17 83.68 86.14 88.55 90.92 93.24 95.53 97.78 100.00 (72.54°) FS = 0.3 PF 0.00 7.90 11.18 13.70 15.82 17.70 19.40 20.96 22.41 23.78 25.08 27.50 29.73 31.81 33.77 35.62 37.39 39.09 40.72 42.30 43.82 45.30 46.73 48.13 49.49 50.83 52.13 53.40 54.05 55.88 57.08 58.27 59.43 60.58 61.71 62.82 65.01 67.13 69.21 71.25 73.24 75.20 77.12 79.01 80.87 82.71 84.52 86.31 88.08 89.83 91.56 93.28 94.98 96.67 98.34 100.00 0 to ±50 mVdc and 0 to ±0.5 mAdc Units—PF-1, PF-2, PF-3 Models 1 Element, Single Phase, 2 Wire L1 - - + 1 2 LINE L2 L3 N DC OUTPUT DC OUTPUT 4 3 5 + 1 6 2 4 3 5 6 LOAD LOAD P-Option Units—PF-1, PF-2, PF-3 Models 1 Element, Single Phase, 2 Wire - DC OUTPUT 3 Element, 3 Phase, 4 Wire, Wye LINE L1 L2 L1 - + DC OUTPUT 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 EXTERNAL AUX. POWER LOAD 0 to ±50 mVdc and 0 to ±0.5 mAdc Units—PF-34 Models P-Option Units—PF-34 Models 3 Element, 3 Phase, 4 Wire, Wye 3 Element, 3 Phase, 4 Wire, Wye EXTERNAL AUX. POWER DC OUTPUT L1 + 1 2 3 4 5 LINE L2 L3 6 N - DC OUTPUT 8 9 10 11 L1 LINE L2 L3 N + 1 2 220V 120V JUMPER JUMPER 7 N EXTERNAL AUX. POWER LOAD - LINE L2 L3 + 1 3 4 5 6 220V 120V JUMPER JUMPER 12 7 8 9 10 11 12 LOAD LOAD Adjust NOTE: Connections for 3 Phase, 3 Wire PF-34 Models are the same, except there is no "N" line. AMETEK® Power Instruments 66 SCI Transducer Cat. 52-89(MTD) 3 Element, 3 Phase, 4 Wire, Wye LINE L1 L2 Exceltronic Power Factor 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 67 66-67 1/9/02, 5:28 PM Wiring Diagrams Exceltronic AC Phase Angle (Power Factor) Transducers Conversion Table Exceltronic AC Phase Angle (Power Factor) Transducers CONVERSION TABLE (% Full Scale to Power Factor) WIRING DIAGRAMS FOR 0 to ±50 mVdc AND 0 to ±0.5 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) Percent Full Scale Angle Angle in Decimals 1.000 .995 .990 .985 .980 .975 .970 .965 .960 .955 .950 .940 .930 .920 .910 .900 .890 .880 .870 .860 .850 .840 .830 .820 .810 .800 .790 .780 .770 .760 .750 .740 .730 .720 .710 .700 .680 .660 .640 .620 .600 .580 .560 .540 .520 .500 .480 .460 .440 .420 .400 .380 .360 .340 .320 .300 0°0' 5°44' 8°6.6' 9°56' 11°29' 12°50' 14°4.2' 15°12' 16°16' 17°15' 18°12' 19°57' 21°34' 23°4.4' 24°30' 25°50.5' 27°8' 28°21.5' 29°32.5' 30°41' 31°47' 32°52' 33°54' 34°55' 35°54' 36°52' 37°49' 38°44' 39°39' 40°32' 41°25' 42°16' 43°7' 43°57' 44°46' 45°34' 47°9' 48°42' 50°12.5' 51°41' 53°8' 54°33' 55°57' 57°19' 58°40' 60°0' 61°19' 62°37' 63°54' 65°10' 66°25' 67°40' 68°54' 70°7.4' 71°20.2' 72°32.5' 0.00° 5.73° 8.11° 9.94° 11.48° 12.84° 14.07° 15.20° 16.26° 17.25° 18.19° 19.95° 21.57° 23.07° 24.49° 25.84° 27.13° 28.36° 29.54° 30.68° 31.79° 32.86° 33.90° 34.92° 35.90° 36.87° 37.81° 38.74° 39.65° 40.54° 41.41° 42.27° 43.11° 43.95° 44.77° 45.57° 47.16° 48.70° 50.21° 51.68° 53.13° 54.55° 55.94° 57.32° 58.67° 60.00° 61.31° 62.61° 63.90° 65.17° 66.42° 67.67° 68.90° 70.12° 71.34° 72.54° AMETEK® Power Instruments 255 North Union Street (45.57°) FS = 0.7 PF 0.00 12.58 17.80 21.80 25.19 28.17 30.87 33.36 35.70 37.86 39.92 43.77 47.32 50.63 53.75 56.70 59.52 62.22 64.82 67.32 69.75 72.10 74.39 76.61 78.78 80.90 82.98 85.01 86.99 88.95 90.86 92.75 94.60 96.43 98.23 100.00 Rochester, New York 14605 (60°) FS = 0.5 PF 0.00 9.56 13.52 16.56 19.13 21.40 23.45 25.34 27.10 28.76 30.32 33.25 35.94 38.46 40.82 43.07 45.21 47.26 49.24 51.14 52.98 54.77 56.50 58.19 59.84 61.45 63.02 64.57 66.08 67.56 69.02 70.45 71.86 73.24 74.61 75.95 78.59 81.17 83.68 86.14 88.55 90.92 93.24 95.53 97.78 100.00 Phone: 1-800-274-5368 (72.54°) FS = 0.3 PF 0.00 7.90 11.18 13.70 15.82 17.70 19.40 20.96 22.41 23.78 25.08 27.50 29.73 31.81 33.77 35.62 37.39 39.09 40.72 42.30 43.82 45.30 46.73 48.13 49.49 50.83 52.13 53.40 54.05 55.88 57.08 58.27 59.43 60.58 61.71 62.82 65.01 67.13 69.21 71.25 73.24 75.20 77.12 79.01 80.87 82.71 84.52 86.31 88.08 89.83 91.56 93.28 94.98 96.67 98.34 100.00 0 to ±50 mVdc and 0 to ±0.5 mAdc Units—PF-1, PF-2, PF-3 Models 1 Element, Single Phase, 2 Wire L1 - - + 1 2 LINE L2 L3 N DC OUTPUT DC OUTPUT 4 3 5 + 1 6 2 4 3 5 6 LOAD LOAD P-Option Units—PF-1, PF-2, PF-3 Models 1 Element, Single Phase, 2 Wire - DC OUTPUT 3 Element, 3 Phase, 4 Wire, Wye LINE L1 L2 L1 - + DC OUTPUT 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 EXTERNAL AUX. POWER LOAD 0 to ±50 mVdc and 0 to ±0.5 mAdc Units—PF-34 Models P-Option Units—PF-34 Models 3 Element, 3 Phase, 4 Wire, Wye 3 Element, 3 Phase, 4 Wire, Wye EXTERNAL AUX. POWER DC OUTPUT L1 + 1 2 3 4 5 LINE L2 L3 6 N - DC OUTPUT 8 9 10 11 L1 LINE L2 L3 N + 1 2 220V 120V JUMPER JUMPER 7 N EXTERNAL AUX. POWER LOAD - LINE L2 L3 + 1 3 4 5 6 220V JUMPER 12 7 8 9 120V JUMPER 10 11 12 LOAD LOAD Adjust NOTE: Connections for 3 Phase, 3 Wire PF-34 Models are the same, except there is no "N" line. Fax: 585-454-7805 66 SCI Transducer Cat. 52-89(MTD) 3 Element, 3 Phase, 4 Wire, Wye LINE L1 L2 Exceltronic Power Factor 67 66-67 1/9/02, 5:28 PM SCIENTIFIC Exceltronic AC Phase Angle or Voltage Angle Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC AC PHASE ANGLE OR VOLTAGE ANGLE TRANSDUCERS Specifications Current Input The Model 6314 Voltage Angle Transducers measure the angle between two voltage inputs. All 6330 and 6314 models have a ±180° phase detector which prevents ambiguous readings when the input goes beyond full scale. The unique circuits use both zero-crossing times to measure the angle. They use phase-locked loops to reduce the effects of noise interference and harmonics on the inputs. Nominal Range Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range Overload Continuous Burden/Element Second Voltage Input Nominal Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden 0 to ±1 mAdc (Phase Angle Transducer) 5A 0.5–5 A 10 A 250 A 0.2 VA (maximum) at 5 A N/A 120 V 50–135 V 150 V 2.2 VA (maximum) at 120 V N/A None Required 100–130 Vac 50–500 Hz 3 VA Nominal ◆ Angle ranges from ± 45° to ±180° ◆ Circuits reduce noise & harmonic interference Applications ◆ SCADA Outputs ◆ 0 to ±1 mAdc ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* ±1° at 25° C Phase Angle Range (without ambiguous readings) 0 to ± 45°, 0 to ±60°, 0 to ±75°, and 0 to ±180° Temperature Effect on Accuracy ± 0.5° over Temperature Range ± 0.6° over Temperature Range ±0.5° over Temperature Range ±0.6° over Temperature Range Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage ◆ Substation monitoring ◆ 1–3–5 mAdc ◆ Generating stations ◆ 4–12–20 mAdc Output Ripple Peak ◆ 10–30–50 mAdc Response Time 10 Vdc 0–10,000 Ω Load Standard Calibration Adjustments Gain Zero Stability (per year) 10 Vdc See Table 2 on page 66. 0–10,000 Ω < 1% RO < 0.5% RO < 1% RO < 0.5% RO < 1 Second to 99% < 400 ms to 99% < 1 Second to 99% ±3% of Reading (minimum) ±20% of Span (minimum) ± 2% RO (minimum) ±5% of Zero Point (minimum) ±3% of Reading (minimum) ±20% of Span (minimum) ± 2% RO (minimum) ±5% of Zero Point (minimum) Nominal ± 3% ±1% RO, Noncumulative ± 1% of Span, Noncumulative Complete (Input/Output/Case) Complete (Input/Output/Power/Case) Operating Humidity ± 1% RO, Noncumulative Isolation Dielectric Withstand 1500 VRMS at 60 Hz ◆ One or two phase angle or voltage angle transducers in one module ◆ Two, four, or eight modules in one enclosure Surge Withstand ANSI/IEEE C37.90.1 Approximate Dimensions (excluding mounting plate) ◆ Easy to install, expand, or repair ±1% of Span, Noncumulative 0–95% Noncondensing Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. Maximum Net Weight See Table 2 on page 66. < 400 ms to 99% Frequency ◆ Convenient front-panel access for calibration and outputcurrent jacks available 100–130 Vac 50–500 Hz 3 VA Nominal None Required Accuracy Features P-Option* (Voltage Angle Transducer) 120 V 95–135 V 150 V 4 VA (maximum) at 120 V ±1 mAdc for Standard Calibration Rated Output (RO)** 0 to ±1 mAdc (Voltage Angle Transducer) P-Option* (Phase Angle Transducer) Exceltronic Model 6330 Phase Angle Transducers measure the phase angle between one voltage and one current input. These units are more stable and accurate than the PF Series Phase Angle Transducers used for determining power factor; they also provide a wider range of measurement. Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 2 lbs., 2 oz. (1 kg) 3 lbs., 8 oz. (1.6 kg) 2 lbs., 2 oz. (1 kg) 3 lbs., 8 oz. (1.6 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. * P-Option includes 1–3–5, 4–12–20, and 10–30–50 mAdc outputs. **For Phase Angle units, output is positive when current lags voltage. For Voltage Angle units, output is positive when “B” lags “A”. See pages 77–94 for more information. AMETEK® Power Instruments 68 SCI Transducer Cat. 52-89(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 69 68-69 1/9/02, 5:28 PM SCIENTIFIC Exceltronic AC Phase Angle or Voltage Angle Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC AC PHASE ANGLE OR VOLTAGE ANGLE TRANSDUCERS Specifications Current Input The Model 6314 Voltage Angle Transducers measure the angle between two voltage inputs. All 6330 and 6314 models have a ±180° phase detector which prevents ambiguous readings when the input goes beyond full scale. The unique circuits use both zero-crossing times to measure the angle. They use phase-locked loops to reduce the effects of noise interference and harmonics on the inputs. Nominal Range Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range Overload Continuous Burden/Element Second Voltage Input Nominal Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden 0 to ±1 mAdc (Phase Angle Transducer) 5A 0.5–5 A 10 A 250 A 0.2 VA (maximum) at 5 A N/A 120 V 50–135 V 150 V 2.2 VA (maximum) at 120 V N/A None Required 100–130 Vac 50–500 Hz 3 VA Nominal None Required 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* Applications ◆ Angle ranges from ± 45° to ±180° ◆ SCADA ◆ Circuits reduce noise & harmonic interference Outputs ◆ 0 to ±1 mAdc ±1 mAdc for Standard Calibration Phase Angle Range (without ambiguous readings) 5, 20, or 50 mAdc for Std. Calibration, depending on selected output range* 0 to ± 45°, 0 to ±60°, 0 to ±75°, and 0 to ±180° Temperature Effect on Accuracy ± 0.5° over Temperature Range ± 0.6° over Temperature Range ±0.5° over Temperature Range ±0.6° over Temperature Range Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage ◆ Substation monitoring ◆ 1–3–5 mAdc ◆ Generating stations ◆ 4–12–20 mAdc Output Ripple Peak ◆ 10–30–50 mAdc Response Time 10 Vdc 0–10,000 Ω Load Standard Calibration Adjustments Gain Zero Stability (per year) 10 Vdc See Table 2 on page 66. 0–10,000 Ω < 1% RO < 0.5% RO < 1% RO < 0.5% RO < 1 Second to 99% < 400 ms to 99% < 1 Second to 99% ±3% of Reading (minimum) ±20% of Span (minimum) ± 2% RO (minimum) ±5% of Zero Point (minimum) ±3% of Reading (minimum) ±20% of Span (minimum) ± 2% RO (minimum) ±5% of Zero Point (minimum) Nominal ± 3% ±1% RO, Noncumulative ± 1% of Span, Noncumulative Complete (Input/Output/Case) Complete (Input/Output/Power/Case) Operating Humidity ± 1% RO, Noncumulative Isolation Dielectric Withstand 1500 VRMS at 60 Hz ◆ One or two phase angle or voltage angle transducers in one module ◆ Two, four, or eight modules in one enclosure Surge Withstand ANSI/IEEE C37.90.1 Approximate Dimensions (excluding mounting plate) ◆ Easy to install, expand, or repair ±1% of Span, Noncumulative 0–95% Noncondensing Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. Maximum Net Weight See Table 2 on page 66. < 400 ms to 99% Frequency ◆ Convenient front-panel access for calibration and outputcurrent jacks available 100–130 Vac 50–500 Hz 3 VA Nominal ±1° at 25° C Accuracy Features P-Option* (Voltage Angle Transducer) 120 V 95–135 V 150 V 4 VA (maximum) at 120 V ±1 mAdc for Standard Calibration Rated Output (RO)** 0 to ±1 mAdc (Voltage Angle Transducer) P-Option* (Phase Angle Transducer) Exceltronic Model 6330 Phase Angle Transducers measure the phase angle between one voltage and one current input. These units are more stable and accurate than the PF Series Phase Angle Transducers used for determining power factor; they also provide a wider range of measurement. Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 2 lbs., 2 oz. (1 kg) 3 lbs., 8 oz. (1.6 kg) 2 lbs., 2 oz. (1 kg) 3 lbs., 8 oz. (1.6 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 * P-Option includes 1–3–5, 4–12–20, and 10–30–50 mAdc outputs. **For Phase Angle units, output is positive when current lags voltage. For Voltage Angle units, output is positive when “B” lags “A”. Specifications subject to change without notice. See pages 77–94 for more information. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 68 SCI Transducer Cat. 52-89(MTD) 69 68-69 1/9/02, 5:28 PM Ordering Procedure Exceltronic AC Phase Angle or Voltage Angle Transducers Wiring Diagrams Exceltronic AC Phase Angle or Voltage Angle Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) ORDERING PROCEDURE Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Base Model No. Output Angle Range Designator Table 1 Table 2 Table 1 0 to ± 1 mAdc output 6330 EXAMPLES: External Aux. Power 0 to ±1 mAdc Units 60 6330 PA7-B Model 6314 Voltage Angle Model 6330 Phase Angle LINE L1 L2 LINE L1 L2 180 Consult factory for options DC OUTPUT DC OUTPUT All P-Option units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. - + 1 2 LINE L1 L2 Exceltronic P-Option outputs Options 3 4 5 6 6330-60 0 to ±1 mAdc Phase Angle Transducer, 0 to ±60° input range. + 1 2 3 4 5 6 LOAD LOAD LOAD SYSTEM A SYSTEM B LINE L1 L2 LINE L1 L2 6330PA7-B-180 4-12-20 mAdc Phase Angle Transducer, 0 to ±180° input range. P-Option Units Table 1 Base Model Number Selection Model 6330 Phase Angle Phase Angle Model No. 6330 VoltageAngle Model No. 6314 Angle Range Designator 45 60 75 180 Power Factor 1 to ±0.7071 1 to ±0.5 1 to ±0.2588 1 to -1 and -1 to 1 Standard Calibration Input Output 0 to ±45° 0 to ±1mAdc 0 to ±60° 0 to ±1mAdc 0 to ±75° 0 to ±1mAdc 0 to ±180° 0 to ±1mAdc Model 6314 Voltage Angle LINE L1 L2 DC OUTPUT - DC OUTPUT + - + 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 Table 2 Output Selection If one of the bidirectional outputs at right is required, indicate the appropriate P-Option in the "Output" position of the complete model number. P-Option PAN6-B PAN7-B PAN8-B Output Range 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc PA6-B PA7-B PA8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Please consult the factory if you require any options with Phase Angle or Voltage Angle Transducers. EXTERNAL AUX. POWER EXTERNAL AUX. POWER LOAD LOAD SYSTEM A SYSTEM B Adjust AMETEK® Power Instruments 70 SCI Transducer Cat. 52-89(MTD) LOAD 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 71 70-71 1/9/02, 5:28 PM Ordering Procedure Exceltronic AC Phase Angle or Voltage Angle Transducers Wiring Diagrams Exceltronic AC Phase Angle or Voltage Angle Transducers WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) ORDERING PROCEDURE Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Base Model No. Output Angle Range Designator Table 1 Table 2 Table 1 0 to ± 1 mAdc output 6330 EXAMPLES: External Aux. Power 0 to ±1 mAdc Units 60 6330 PA7-B Model 6314 Voltage Angle Model 6330 Phase Angle LINE L1 L2 LINE L1 L2 180 Consult factory for options DC OUTPUT DC OUTPUT All P-Option units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. - + 1 2 LINE L1 L2 Exceltronic P-Option outputs Options 3 4 5 6 6330-60 0 to ±1 mAdc Phase Angle Transducer, 0 to ±60° input range. + 1 2 3 4 5 6 LOAD LOAD LOAD SYSTEM A SYSTEM B LINE L1 L2 LINE L1 L2 6330PA7-B-180 4-12-20 mAdc Phase Angle Transducer, 0 to ±180° input range. P-Option Units Table 1 Base Model Number Selection Model 6330 Phase Angle Phase Angle Model No. 6330 VoltageAngle Model No. 6314 Angle Range Designator 45 60 75 180 Power Factor 1 to ±0.7071 1 to ±0.5 1 to ±0.2588 1 to -1 and -1 to 1 Standard Calibration Input Output 0 to ±45° 0 to ±1mAdc 0 to ±60° 0 to ±1mAdc 0 to ±75° 0 to ±1mAdc 0 to ±180° 0 to ±1mAdc Model 6314 Voltage Angle LINE L1 L2 DC OUTPUT - DC OUTPUT + - + 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 Table 2 Output Selection If one of the bidirectional outputs at right is required, indicate the appropriate P-Option in the "Output" position of the complete model number. P-Option PAN6-B PAN7-B PAN8-B Output Range 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc PA6-B PA7-B PA8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Please consult the factory if you require any options with Phase Angle or Voltage Angle Transducers. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 EXTERNAL AUX. POWER EXTERNAL AUX. POWER LOAD LOAD SYSTEM A SYSTEM B Adjust Fax: 585-454-7805 70 SCI Transducer Cat. 52-89(MTD) LOAD 71 70-71 1/9/02, 5:28 PM SCIENTIFIC Exceltronic AC Frequency Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC AC FREQUENCY TRANSDUCERS Frequency transducers have an expanded-scale output. A variety of calibrations may be ordered, or the user may calibrate the transducer at the installation site to meet specific requirements. 0–1 mAdc (Frequency Transducer) Specifications Voltage Input 120 V 90–150 V 150 V 2 VA (maximum) at 120 V Nominal Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Accuracy 1 mAdc at Maximum Rated Frequency 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* ±0.02% of Center Frequency at 25° C ±0.05% of Center Frequency at 25° C Temperature Effect on Accuracy ±0.0025% / ° C ±0.01% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc Output Ripple Peak ◆ Filtering for fast-response devices ◆ Series components & devices added without recalibration Applications Outputs Response Time Standard Calibration Adjustments ◆ Process control ◆ 0–1 mAdc Stability (per year) ◆ Generating stations ◆ 1–5 mAdc Operating Humidity ◆ Substation monitoring ◆ 4–20 mAdc ◆ 10–50 mAdc Gain Zero < 1% RO < 0.25% of Span < 400 ms to 99% < 1 Second to 99% ±5% of Span (minimum) ±10% of Span (minimum) ±20% of Span (minimum) ±5% of Zero Point (minimum) ±0.02% of Center Frequency ±0.04% of Center Frequency 0–95% Noncondensing Isolation Complete (Input/Output/Case) Dielectric Withstand Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight ◆ Variety of calibration available See Table 2 on page 70. 0–10,000 Ω Load Features 100–130 Vac 50–500 Hz 3 VA Nominal None Required Exceltronic Customers can add series components and devices to the output signal circuit without having to recalibrate these transducers. Series components and devices include: indicators, recorders, resistors for alarms, and analog-to-digital pick-off points. P-Option* (Frequency Transducer) 1 lb., 14 oz. (0.9 kg) Approximate Dimensions (excluding mounting plate) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 *P-Option includes 1-5, 4-20, and 10-50 mAdc outputs. 3 lbs., 1 oz. (1.4 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. ◆ One or two frequency transducers in one module ◆ Two, four, or eight modules in one enclosure ◆ Easy to install, expand, or repair ◆ Convenient front-panel access for calibration and outputcurrent jacks available See pages 77–94 for more information. AMETEK® Power Instruments 72 SCI Transducer Cat. 52-89(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 73 72-73 1/9/02, 5:28 PM SCIENTIFIC Exceltronic AC Frequency Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC AC FREQUENCY TRANSDUCERS Frequency transducers have an expanded-scale output. A variety of calibrations may be ordered, or the user may calibrate the transducer at the installation site to meet specific requirements. 0–1 mAdc (Frequency Transducer) Specifications Voltage Input 120 V 90–150 V 150 V 2 VA (maximum) at 120 V Nominal Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Accuracy 1 mAdc at Maximum Rated Frequency 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* ±0.02% of Center Frequency at 25° C ±0.05% of Center Frequency at 25° C Temperature Effect on Accuracy ±0.0025% / ° C ±0.01% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc Output Ripple Peak Applications ◆ Filtering for fast-response devices ◆ Series components & devices added without recalibration Outputs Response Time Standard Calibration Adjustments ◆ Process control ◆ 0–1 mAdc Stability (per year) ◆ Generating stations ◆ 1–5 mAdc Operating Humidity ◆ Substation monitoring Gain Zero Isolation ◆ 4–20 mAdc < 1% RO < 0.25% of Span < 400 ms to 99% < 1 Second to 99% ±5% of Span (minimum) ±10% of Span (minimum) ±20% of Span (minimum) ±5% of Zero Point (minimum) ±0.02% of Center Frequency ±0.04% of Center Frequency 0–95% Noncondensing Complete (Input/Output/Case) Dielectric Withstand ◆ 10–50 mAdc Maximum Net Weight Approximate Dimensions (excluding mounting plate) *P-Option includes 1-5, 4-20, and 10-50 mAdc outputs. Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ◆ Variety of calibration available See Table 2 on page 70. 0–10,000 Ω Load Features 100–130 Vac 50–500 Hz 3 VA Nominal None Required Exceltronic Customers can add series components and devices to the output signal circuit without having to recalibrate these transducers. Series components and devices include: indicators, recorders, resistors for alarms, and analog-to-digital pick-off points. P-Option* (Frequency Transducer) ANSI/IEEE C37.90.1 1 lb., 14 oz. (0.9 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 3 lbs., 1 oz. (1.4 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. ◆ One or two frequency transducers in one module ◆ Two, four, or eight modules in one enclosure ◆ Easy to install, expand, or repair ◆ Convenient front-panel access for calibration and outputcurrent jacks available See pages 77–94 for more information. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 72 SCI Transducer Cat. 52-89(MTD) 73 72-73 1/9/02, 5:28 PM Ordering Procedure Exceltronic AC Frequency Transducers Ordering Procedure Exceltronic AC Frequency Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option 0-1 mAdc output Output Table 1 6281B Table 2 Table 3 6281 PAN7 A4 If A2 is selected, leave space blank; specify ext. aux. power voltage at end of model no. EXAMPLES: Scaling Resistor Option #1 Option #2 Option #3 External Auxiliary Power Table 4 Table 5 Table 5 Table 3 -RS -SM Specify voltage range (P-Option Units) A2** (leave blank) A4 External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) -Z If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Option -RS*** Description Scaling Resistor *** You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 5 Other Options Option -24 -Z Input Range * All 0-1 mAdc output units are calibrated for 0.5 mAdc output at center frequency. Description 24 Vdc Loop-Powered (PA7 models only) (consult factory for specifications) Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units) If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) (P-Option Units) 6281 6283 6284 45-55 Hz 375-425 Hz 55-65 Hz Frequency 0-1 mAdc Units Frequency P-Option Units Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. 3 VA 3 VA Table 4 Scaling Resistor (-RS) Option -SM 45-55 Hz 375-425 Hz 55-65 Hz 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency DC external auxiliary power available; see Special Options on page 128. Table 1 Base Model Number Selection 6281B 6283B 6284B Burden ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) 6281PAN7A4-RS-SM-Z 45-55 Hz, 4-20 mAdc Frequency Transducer; internal auxiliary power; resistor scaling; seismic brace; zero-based output calibration (-Z option converts 4-20 mAdc output to 0-20 mAdc output and -RS option converts current output to voltage output). Model No. Frequency Range None Required 6281B-RS-SM 45-55 Hz, 0-1 mAdc Frequency Transducer; resistor scaling (converts current output to voltage output); seismic brace. (0-1 mAdc Units)* Input Range Exceltronic P-Option outputs Base Model No. Auxiliary Power Description (0-1 mAdc Units) P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc AC DC INPUT OUTPUT - + 1 2 - DC OUTPUT EXTERNAL AUX. POWER + 1 3 AC INPUT 2 3 4 5 6 4 Adjust AMETEK® Power Instruments 74 SCI Transducer Cat. 52-89(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 75 74-75 1/9/02, 5:29 PM Ordering Procedure Exceltronic AC Frequency Transducers Ordering Procedure Exceltronic AC Frequency Transducers ORDERING PROCEDURE Table 3 Auxiliary Power Supply Selection Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option 0-1 mAdc output Output Table 1 6281B Table 2 Table 3 6281 PAN7 A4 If A2 is selected, leave space blank; specify ext. aux. power voltage at end of model no. EXAMPLES: Scaling Resistor Option #1 Option #2 Option #3 External Auxiliary Power Table 4 Table 5 Table 5 Table 3 -RS -SM Specify voltage range (P-Option Units) A2** (leave blank) A4 External Auxiliary Power (120 Vac std.) Internal Auxiliary Power (self-powered) -Z If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Option -RS*** Description Scaling Resistor *** You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. Table 5 Other Options Option -24 -Z Input Range * All 0-1 mAdc output units are calibrated for 0.5 mAdc output at center frequency. Description 24 Vdc Loop-Powered (PA7 models only) (consult factory for specifications) Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units) If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) (P-Option Units) 6281 6283 6284 45-55 Hz 375-425 Hz 55-65 Hz Frequency 0-1 mAdc Units Frequency P-Option Units Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. 3 VA 3 VA Table 4 Scaling Resistor (-RS) Option -SM 45-55 Hz 375-425 Hz 55-65 Hz 100-130 Vac 50-500 Hz 84-108% of Nominal Aux. Power Voltage Equals Input Frequency DC external auxiliary power available; see Special Options on page 128. Table 1 Base Model Number Selection 6281B 6283B 6284B Burden ** For external auxiliary power voltages other than 120 Vac, specify the voltage in the last position of the complete model number. (Example: 240 Vac Aux.) 6281PAN7A4-RS-SM-Z 45-55 Hz, 4-20 mAdc Frequency Transducer; internal auxiliary power; resistor scaling; seismic brace; zero-based output calibration (-Z option converts 4-20 mAdc output to 0-20 mAdc output and -RS option converts current output to voltage output). Model No. Frequency Range None Required 6281B-RS-SM 45-55 Hz, 0-1 mAdc Frequency Transducer; resistor scaling (converts current output to voltage output); seismic brace. (0-1 mAdc Units)* Input Range Exceltronic P-Option outputs Base Model No. Auxiliary Power Description (0-1 mAdc Units) P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc AC DC INPUT OUTPUT - + 1 2 - DC OUTPUT EXTERNAL AUX. POWER + 1 3 AC INPUT 2 3 4 5 6 4 Adjust AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 74 SCI Transducer Cat. 52-89(MTD) 75 74-75 1/9/02, 5:29 PM SCIENTIFIC Exceltronic Temperature Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC TEMPERATURE TRANSDUCERS Specifications 0–1 mAdc (Temperature Transducer) P-Option* (Temperature Transducer) 90–130 Vac 50–500 Hz 3.5 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 1 mAdc at Maximum Calibrated Temperature 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Accuracy See Table 1 on page 74. Temperature Effect on Accuracy ±0.015% / ° F ±0.02% / ° F Operating Temperature Range -20° C to +60° C (-4° F to +140° F) -20° C to +50° C (-4° F to +122° F) Compliance Voltage 10 Vdc Open Circuit Voltage Output Ripple Peak < 1% RO Response Time Standard Calibration Adjustments Features ◆ Compatible with nickel-iron, platinum, & copper RTDs ◆ Exceptional reliability ◆ Wide range of operating temperatures Applications Outputs < 50 ms to 99% < 1 Second to 99% ±10% of Span (minimum) ±3% of Span (minimum) ± 20% of Span (minimum) ±5% of Zero Point (minimum) ± 0.4% RO, Noncumulative ± 0.5% of Span, Noncumulative 0–95% Noncondensing Isolation ◆ Substation monitoring ◆ 1–5 mAdc Surge Withstand ◆ 4–20 mAdc Maximum Net Weight ◆ Excellent long-term stability < 0.25% of Span Operating Humidity ◆ 0–1 mAdc ◆ 10–50 mAdc Gain Zero Stability (per year) ◆ Process control ◆ Generating stations See Table 2 on page 74. 16 Vdc 0–10,000 Ω Load Input/Power/Case and Output/Power/Case Dielectric Withstand Approximate Dimensions (excluding mounting plate) Exceltronic Scientific Columbus temperature transducers offer an accurate, inexpensive method of measuring temperature through interface with a variety of RTD sensor types. These transducers have true current outputs that will simplify your own calibrating or scaling networks, as well as allow telemetering over long distances without line-drop error. To achieve higher accuracy, the true current output is compensated to be proportional to true temperature changes, rather than merely the resistance change of the RTD. 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 2 lbs., 1 oz. (0.9 kg) 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 Model 9015N 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 Models 9016P & 9019C 3 lbs., 8 oz. (1.6 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. *P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. ◆ One or two temperature transducers in one module ◆ Two, four, or eight modules in one enclosure ◆ Easy to install, expand, or repair ◆ Convenient front-panel access for calibration and outputcurrent jacks available See pages 77–94 for more information. AMETEK® Power Instruments 76 SCI Transducer Cat. 52-89(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 77 76-77 1/9/02, 5:29 PM SCIENTIFIC Exceltronic Temperature Transducers COLUMBUS SCIENTIFIC Specifications COLUMBUS EXCELTRONIC TEMPERATURE TRANSDUCERS Specifications 0–1 mAdc (Temperature Transducer) P-Option* (Temperature Transducer) 90–130 Vac 50–500 Hz 3.5 VA Nominal 100–130 Vac 50–500 Hz 6 VA Nominal 1 mAdc at Maximum Calibrated Temperature 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) Accuracy See Table 1 on page 74. Temperature Effect on Accuracy ±0.015% / ° F ±0.02% / ° F Operating Temperature Range -20° C to +60° C (-4° F to +140° F) -20° C to +50° C (-4° F to +122° F) Compliance Voltage 10 Vdc Open Circuit Voltage Output Ripple Peak < 1% RO Response Time Standard Calibration Adjustments Applications Features ◆ Compatible with nickel-iron, platinum, & copper RTDs ◆ Exceptional reliability Outputs < 0.25% of Span < 50 ms to 99% < 1 Second to 99% ±10% of Span (minimum) ±3% of Span (minimum) ± 20% of Span (minimum) ±5% of Zero Point (minimum) ± 0.4% RO, Noncumulative ± 0.5% of Span, Noncumulative 0–95% Noncondensing Operating Humidity Isolation ◆ 0–1 mAdc ◆ Substation monitoring ◆ 1–5 mAdc Surge Withstand ◆ 4–20 mAdc Maximum Net Weight ◆ Wide range of operating temperatures Gain Zero Stability (per year) ◆ Process control ◆ Generating stations See Table 2 on page 74. 16 Vdc 0–10,000 Ω Load Input/Power/Case and Output/Power/Case Dielectric Withstand Approximate Dimensions (excluding mounting plate) ◆ 10–50 mAdc ◆ Excellent long-term stability Exceltronic Scientific Columbus temperature transducers offer an accurate, inexpensive method of measuring temperature through interface with a variety of RTD sensor types. These transducers have true current outputs that will simplify your own calibrating or scaling networks, as well as allow telemetering over long distances without line-drop error. To achieve higher accuracy, the true current output is compensated to be proportional to true temperature changes, rather than merely the resistance change of the RTD. 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 2 lbs., 1 oz. (0.9 kg) Model 9015N Models 9016P & 9019C *P-Option includes 1–5, 4–20, and 10–50 mAdc outputs. 3.3" W x 2.1" D x 4.1" H (84 mm x 53 mm x 104 mm) Style III Case, see page 122 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 3 lbs., 8 oz. (1.6 kg) 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 Specifications subject to change without notice. Also available in XLP modular, plug-in format for limitedspace applications requiring large numbers of transducers. ◆ One or two temperature transducers in one module ◆ Two, four, or eight modules in one enclosure ◆ Easy to install, expand, or repair ◆ Convenient front-panel access for calibration and outputcurrent jacks available See pages 77–94 for more information. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 76 SCI Transducer Cat. 52-89(MTD) 77 76-77 1/9/02, 5:29 PM Ordering Procedure Exceltronic Temperature Transducers Ordering Procedure Exceltronic Temperature Transducers ORDERING PROCEDURE Table 3 Scaling Resistor (-RS) Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option -RS Base Model No. Output Scaling Resistor Option #1 Table 1 Table 2 Table 3 Option #2 Option #3 Table 4 Table 4 External Auxiliary Power Table 4 Other Options -RS PAN7 Option -24 -SM Specify output voltage All units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. -Z -SM -Z Description 24 Vdc Loop-Powered (PA7 models only) (consult factory for specifications) Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units) 9019C-RS-SM 0-1 mAdc Temperature Transducer for use with copper RTD, resistor scaling (converts current output to voltage output), seismic brace. WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Styles III & II Cases) AND P-OPTION UNITS (Style I Case) 9019CPAN7-RS-SM-Z 4-20 mAdc Temperature Transducer for use with copper RTD, resistor scaling, seismic brace, zero-based output calibration (-Z option converts 4-20 mAdc output to 0-20 mAdc output and -RS option converts current output to voltage output). 9015N Temperature 0-1 mAdc Units (Style III Case) 9016P & 9019C Temperature 0-1 mAdc Units (Style II Case) For Use w/ RTD Type Nickel-Iron Platinum Copper RTD Resistance 676 Ω at 77° F 100 Ω at 32° F 10 Ω at 77° F EXTERNAL AUX. POWER DC OUTPUT EXTERNAL AUX. POWER Table 1 Base Model Number Selection Model No. 9015N 9016P** 9019C If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. - DC OUTPUT Temperature Range* -200° F to +500° F -320° F to +1000° F -100° F to +300° F Temperature Span* 50° F thru 150° F 150° F thru 300° F 150° F thru 300° F Measurement Accuracy ±0.4° F or ±1° F ±0.8° F or ±1.5° F ±1° F or ±2° F - Maximum RTD Current <3 mAdc <5 mAdc <50 mAdc + 1 2 3 4 5 6 7 8 * You must specify minimum and maximum input temperature values from within the Temperature Range shown for each RTD type. The resulting temperature span (maximum temperature value minus minimum temperature value) must fall within the Temperature Span shown for each RTD type. (Example: Model 9015N temperature range = -195° F to -110° F and temperature span = 85° F.) Exceltronic 9019C EXAMPLES: *** You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. 0-1 mAdc output P-Option outputs Description Scaling Resistor*** + 1 2 3 4 5 6 7 8 RTD RTD This information is not part of the model number, but must be provided to the factory when you place your order. ** You must specify the Temperature Coefficient of Resistance (TCR) of your 100 Ω platinum RTD probe—whether it is designed to the American Standard (TCR = .00392 Ω/Ω/°C), U.S. Industrial Standard (TCR = .00391 Ω/Ω/°C), or European Standard (TCR = .00385 Ω/Ω/°C). This information is not part of the model number, but must be provided to the factory when you place your order. 9015N Temperature P-Option Units (Style I Case) RTD P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc - + 1 2 3 4 5 6 Adjust AMETEK® Power Instruments 78 SCI Transducer Cat. 52-89(MTD) AUX. POWER DC OUTPUT DC OUTPUT Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. EXTERNAL AUX. POWER 9016P & 9019C Temperature P-Option Units (Style I Case) EXTERNAL + 1 2 3 4 5 6 7 8 RTD 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 79 78-79 1/9/02, 5:29 PM Ordering Procedure Exceltronic Temperature Transducers Ordering Procedure Exceltronic Temperature Transducers ORDERING PROCEDURE Table 3 Scaling Resistor (-RS) Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option -RS Base Model No. Output Scaling Resistor Option #1 Table 1 Table 2 Table 3 Option #2 Option #3 Table 4 Table 4 External Auxiliary Power Table 4 Other Options -RS PAN7 Option -24 -SM Specify output voltage All units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. -Z -SM -Z Description 24 Vdc Loop-Powered (PA7 models only) (consult factory for specifications) Seismic Brace (available with 0-1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units) 9019C-RS-SM 0-1 mAdc Temperature Transducer for use with copper RTD, resistor scaling (converts current output to voltage output), seismic brace. WIRING DIAGRAMS FOR 0-1 mAdc UNITS (Styles III & II Cases) AND P-OPTION UNITS (Style I Case) 9019CPAN7-RS-SM-Z 4-20 mAdc Temperature Transducer for use with copper RTD, resistor scaling, seismic brace, zero-based output calibration (-Z option converts 4-20 mAdc output to 0-20 mAdc output and -RS option converts current output to voltage output). 9015N Temperature 0-1 mAdc Units (Style III Case) 9016P & 9019C Temperature 0-1 mAdc Units (Style II Case) For Use w/ RTD Type Nickel-Iron Platinum Copper RTD Resistance 676 Ω at 77° F 100 Ω at 32° F 10 Ω at 77° F EXTERNAL AUX. POWER DC OUTPUT EXTERNAL AUX. POWER Table 1 Base Model Number Selection Model No. 9015N 9016P** 9019C If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. - DC OUTPUT Temperature Range* -200° F to +500° F -320° F to +1000° F -100° F to +300° F Temperature Span* 50° F thru 150° F 150° F thru 300° F 150° F thru 300° F Measurement Accuracy ±0.4° F or ±1° F ±0.8° F or ±1.5° F ±1° F or ±2° F - Maximum RTD Current <3 mAdc <5 mAdc <50 mAdc + 1 2 3 4 5 6 7 8 * You must specify minimum and maximum input temperature values from within the Temperature Range shown for each RTD type. The resulting temperature span (maximum temperature value minus minimum temperature value) must fall within the Temperature Span shown for each RTD type. (Example: Model 9015N temperature range = -195° F to -110° F and temperature span = 85° F.) Exceltronic 9019C EXAMPLES: *** You must specify the desired output voltage: For 0-1 mAdc units, specify range from 0-10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. 0-1 mAdc output P-Option outputs Description Scaling Resistor*** + 1 2 3 4 5 6 7 8 RTD RTD This information is not part of the model number, but must be provided to the factory when you place your order. ** You must specify the Temperature Coefficient of Resistance (TCR) of your 100 Ω platinum RTD probe—whether it is designed to the American Standard (TCR = .00392 Ω/Ω/°C), U.S. Industrial Standard (TCR = .00391 Ω/Ω/°C), or European Standard (TCR = .00385 Ω/Ω/°C). This information is not part of the model number, but must be provided to the factory when you place your order. 9015N Temperature P-Option Units (Style I Case) RTD AMETEK® Power Instruments P-Option PAN6 PAN7 PAN8 PA6 PA7 PA8 Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Adjust 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 - + 1 2 3 4 5 6 + 1 2 3 4 5 6 7 8 RTD Fax: 585-454-7805 78 SCI Transducer Cat. 52-89(MTD) AUX. POWER DC OUTPUT DC OUTPUT Table 2 Output Selection 0-1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0-1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. EXTERNAL AUX. POWER 9016P & 9019C Temperature P-Option Units (Style I Case) EXTERNAL 79 78-79 1/9/02, 5:29 PM MAV 2 Meter Accuracy Verifier The XLP Series of transducers is a family of power instrumentation transducers in a compact, modular plug-in form. XLP transducers are ideal where large quantities of transducers are required, but space is limited. MAV2 offers Simplicity, Safety, and Accuracy — All In One Compact Portable Meter-testing Instrument. The MAV2 Meter Accuracy Verifier is a straightforward, safe, and cost-effective instrument for on-site verification and calibration of self-contained meter accuracy. Every aspect of the MAV2’s design and construction, from its menu-driven operation to the lightweight and compact package, is focused on the needs of the customer service representative or field technician—including accuracy assurance traceable to NIST. The MAV2 Verifier can be used by relatively “less technically trained” customer service personnel as well as trained meter technicians. Designed for safety, the MAV2 incorporates an electrically interlocked deadfront design in the meter socket adapter, insuring that there are no live circuits in the adapter socket until the meter is installed. Anyone qualified to replace a meter in the field is capable of using the MAV2. XLP transducers feature three enclosure widths to accomodate two, four, or eight modules. Each module consists of two parts: a plug-in assembly and a back-panel assembly. For current inputs, the current transformers are located on the back-panel assembly so the current inputs are not opened when the plug-in assembly is removed. New or additional plug-ins or back panels can be added in the field. MAV2 SPECIFICATIONS Watthour Accuracy ±0.1 % of Reading (0.05% typical) Operating Temperature Range -20° C to +60° C (Temperature Effect on Accuracy is 30 ppm/°C) Storage Temperature Range -30° C to +80° C Operating Voltage (Autoranging) 108–264 V (120 Volt L-G Nominal) Test Currents Full Load 15, 30, or 50 A Light Load 1.5, 3, or 5 A Meter Power Interlocks Redundant interlocks, activated by meter insertion, provide dead-front access to MAV2 meter adapter socket. Display Two lines of 16 characters each, 0.3-inch character height, Internally backlit Keyboard Three sealed keys (UP, DOWN, and ENTER) control all operations including Start and Stop of test. Interconnecting Cable Control unit is connected to the meter adapter socket by a spiral cable. Length range is two to seven feet. Disk Rotation Sensor Optional photo optical disk rotation sensor uses reflective measurement. Connecting the sensor automatically sets up the meter for rotation sensor operation. Pendant Snap Switch Optional snap switch is provided on a 30-inch cord. Plugging in the snap switch automatically configures the unit for snap-switch operation. Calibration and Certification Traceable to NIST. User calibration can be performed using the infrared optical pulse port. Calibration is digital, via the front-panel display and keyboard, and requires the installation of an internal hardware key as well as a special keyboard sequence. Size Meter Adapter Socket 7" diameter x 8" deep Hand-held Control Unit 9.6" H x 7" W x 3.7" D Carrying Case 15" H x 13.5" W x 9" D Weight Meter Adapter Socket 6.7 lbs. Hand-held Control Unit 6.4 lbs. Custom Case 3.5 lbs. Modules Available ◆ Current ◆ Voltage ◆ Combined Current/Voltage ◆ Expanded-Scale Voltage ◆ Watt ◆ Var ◆ Combined Watt/Var ◆ Phase Angle ◆ Voltage Angle Applications ◆ Modular concept & compact design save transducer panel space ◆ Substations ◆ Up to six transducers in one module ◆ SCADA ◆ Two, four, or eight modules in one enclosure ◆ Lower installation costs ◆ Easy to install ◆ Convenient front-panel access ◆ Frequency ◆ Generating stations Outputs ◆ 0 to ±1 mAdc ◆ 1–5 or 1–3–5 mAdc ◆ 4–20 or 4–12–20 mAdc ◆ Temperature (RTD) AMETEK® Power Instruments 80 SCI Transducer Cat. 52-89(MTD) Features XLP Plug-In The small size and light weight of the MAV2 Verifier make it possible for the customer service representative or technician to carry it in their vehicle, and bring it to distant locations such as apartment building meter rooms, without any special effort. Full-load testing capability to 50 amps eliminates the need for larger test instruments, and the affordability of the MAV2 makes it practical to have many units in the field. SCIENTIFIC Exceltronic XLP Modular Plug-In Transducers COLUMBUS 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 81 80-81 1/9/02, 5:29 PM MAV 2 Meter Accuracy Verifier The XLP Series of transducers is a family of power instrumentation transducers in a compact, modular plug-in form. XLP transducers are ideal where large quantities of transducers are required, but space is limited. MAV2 offers Simplicity, Safety, and Accuracy — All In One Compact Portable Meter-testing Instrument. The MAV2 Meter Accuracy Verifier is a straightforward, safe, and cost-effective instrument for on-site verification and calibration of self-contained meter accuracy. Every aspect of the MAV2’s design and construction, from its menu-driven operation to the lightweight and compact package, is focused on the needs of the customer service representative or field technician—including accuracy assurance traceable to NIST. The MAV2 Verifier can be used by relatively “less technically trained” customer service personnel as well as trained meter technicians. Designed for safety, the MAV2 incorporates an electrically interlocked deadfront design in the meter socket adapter, insuring that there are no live circuits in the adapter socket until the meter is installed. Anyone qualified to replace a meter in the field is capable of using the MAV2. TIFIE Headquarters 50 Fordham Road CER Wilmington, MA 01887 Tel: 978-988-4101 Fax: 978-988-4179 E-Mail: [email protected] 255 North Union Street Rochester, NY 14605 Tel: 585-263-7700 Fax: 585-454-7805 E-Mail: [email protected] XLP transducers feature three enclosure widths to accomodate two, four, or eight modules. Each module consists of two parts: a plug-in assembly and a back-panel assembly. For current inputs, the current transformers are located on the back-panel assembly so the current inputs are not opened when the plug-in assembly is removed. New or additional plug-ins or back panels can be added in the field. MAV2 SPECIFICATIONS Watthour Accuracy ±0.1 % of Reading (0.05% typical) Operating Temperature Range -20° C to +60° C (Temperature Effect on Accuracy is 30 ppm/°C) Storage Temperature Range -30° C to +80° C Operating Voltage (Autoranging) 108–264 V (120 Volt L-G Nominal) Test Currents Full Load 15, 30, or 50 A Light Load 1.5, 3, or 5 A Meter Power Interlocks Redundant interlocks, activated by meter insertion, provide dead-front access to MAV2 meter adapter socket. Display Two lines of 16 characters each, 0.3-inch character height, Internally backlit Keyboard Three sealed keys (UP, DOWN, and ENTER) control all operations including Start and Stop of test. Interconnecting Cable Control unit is connected to the meter adapter socket by a spiral cable. Length range is two to seven feet. Disk Rotation Sensor Optional photo optical disk rotation sensor uses reflective measurement. Connecting the sensor automatically sets up the meter for rotation sensor operation. Pendant Snap Switch Optional snap switch is provided on a 30-inch cord. Plugging in the snap switch automatically configures the unit for snap-switch operation. Calibration and Certification Traceable to NIST. User calibration can be performed using the infrared optical pulse port. Calibration is digital, via the front-panel display and keyboard, and requires the installation of an internal hardware key as well as a special keyboard sequence. Size Meter Adapter Socket 7" diameter x 8" deep Hand-held Control Unit 9.6" H x 7" W x 3.7" D Carrying Case 15" H x 13.5" W x 9" D Weight Meter Adapter Socket 6.7 lbs. Hand-held Control Unit 6.4 lbs. Custom Case 3.5 lbs. Modules Available ◆ Current ◆ Voltage ◆ Combined Current/Voltage ◆ Expanded-Scale Voltage ◆ Watt ◆ Var ◆ Combined Watt/Var ◆ Phase Angle ◆ Voltage Angle ◆ Frequency Applications ◆ Modular concept & compact design save transducer panel space ◆ Substations ◆ Up to six transducers in one module ◆ SCADA ◆ Two, four, or eight modules in one enclosure ◆ Lower installation costs ◆ Easy to install ◆ Convenient front-panel access ◆ Generating stations Outputs ◆ 0 to ±1 mAdc ◆ 1–5 or 1–3–5 mAdc ◆ 4–20 or 4–12–20 mAdc ◆ Temperature (RTD) D 80 SCI Transducer Cat. 52-89(MTD) Features XLP Plug-In The small size and light weight of the MAV2 Verifier make it possible for the customer service representative or technician to carry it in their vehicle, and bring it to distant locations such as apartment building meter rooms, without any special effort. Full-load testing capability to 50 amps eliminates the need for larger test instruments, and the affordability of the MAV2 makes it practical to have many units in the field. SCIENTIFIC Exceltronic XLP Modular Plug-In Transducers COLUMBUS 81 80-81 1/9/02, 5:29 PM Specifications Exceltronic XLP AC Average-Sensing Current or Voltage Transducers Specifications Current Input Voltage Input Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden/Element 0–1 mAdc Amps (Current Transducer) P-Option* Amps (Current Transducer) 5A 0–5 A 0–10 A 20 A 250 A 0.25 VA (maximum) at 5 A 5A 0–5 A 0–6 A 20 A 250 A 0.25 VA (maximum) at 5 A N/A N/A 120 V 0–150 V 0–150 V 180 V 2.2 VA (maximum) at 120 V N/A 100–130 Vac 50–500 Hz 3 VA Nominal None Required 0–1 mAdc Volts (Voltage Transducer) Specifications P-Option* Volts (Voltage Transducer) Voltage Input N/A 0–1 mAdc Volts (Expanded-Scale Voltage Transducer) 120 V 0–150 V 0–165 V 180 V 2.2 VA (maximum) at 120 V 100–130 Vac 50–500 Hz 3 VA Nominal Rated Output (RO) P-Option* Volts (Expanded-Scale Voltage Transducer) Any 20–60 V span between 90–150 V (customer specified)** 150 V 2 VA (maximum) at 120 V Span/Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden None Required None Required 100–130 Vac 50–500 Hz 3 VA Nominal 0 mAdc at low end of range (customer specified) 1 mAdc at high end of range (customer specified) 1 or 4 mAdc at low end of range (customer specified) 5 or 20 mAdc at high end of range (customer specified) ±0.25% of Input Voltage for 60 Hz Accuracy Temperature Effect on Accuracy ±0.007% / ° C ±0.01% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C 10 Vdc 25 Vdc Load 0–10,000 Ω 0–5,000 Ω for 1–5 mAdc units 0–1,250 Ω for 4–20 mAdc units Output Ripple Peak < 2.5% RO < 2.5% of Span Compliance Voltage Rated Output (RO) = 5 A or 150 V/Element 1 mAdc for Standard Calibration Accuracy Standard A4 Models ±0.25% RO ±0.1% RO ± 0.25% of Span ±0.25% RO ±0.1% RO ± 0.25% of Span Temperature Effect on Accuracy ± 0.01% / ° C ± 0.015% / ° C ±0.01% / ° C ±0.015% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc 25 Vdc 10 Vdc 25 Vdc Frequency Range 55–65 Hz Stability (per year) ± 0.25% of Input Voltage, Noncumulative 1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* Load 0–10,000 Ω 0–5,000 W for 1–5 mAdc units 0–1,250 W for 4–20 mAdc units 0–10,000 Ω 0–5,000 W for 1–5 mAdc units 0–1,250 W for 4–20 mAdc units Output Ripple Peak < 0.25% RO < 0.25% of Span < 0.25% RO < 0.25% of Span Response Time Standard Calibration Adjustments < 400 ms to 99% Gain Zero 50–500 Hz (specify nominal) ±0.1% RO, Noncumulative Stability (per year) ±0.15% of Span, Noncumulative Operating Humidity < 400 ms to 99% ± 0.25% RO, Noncumulative ± 0.3% of Span, Noncumulative ±20% of Span ±5% of Span 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Weights vary by model; consult factory. Maximum Net Weight See enclosure diagrams on page 85. Approximate Dimensions Specifications subject to change without notice. * P-Option includes 1–5 and 4–20 mAdc outputs. **Minimum span must be at least 18% of low-end voltage. 0–95% Noncondensing Isolation Complete (Input/Output/Case) Complete (Input/Output/Power/Case) Dielectric Withstand Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight Weights vary by model; consult factory. Approximate Dimensions See enclosure diagrams on page 85. *P-Option includes 1–5 and 4–20 mAdc outputs. Not available on all models. Specifications subject to change without notice. AMETEK® Power Instruments 82 SCI Transducer Cat. 52-89(MTD) ±5% of Span ±5% of Span Gain Zero Dielectric Withstand ± 10% of Reading (minimum) ±20% of Span (minimum) ± 10% of Reading (minimum) ±20% of Span (minimum) None Required None Required ±5% of Zero Point (minimum) ±5% of Zero Point (minimum) Frequency Range Response Time Standard Calibration Adjustments XLP Plug-In Compliance Voltage 5 or 20 mAdc for Std. Calibration, depending on selected output range* Specifications Exceltronic XLP AC ExpandedScale Voltage Transducers 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 83 82-83 1/9/02, 5:29 PM Specifications Exceltronic XLP AC Average-Sensing Current or Voltage Transducers Specifications Current Input Voltage Input Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden/Element 0–1 mAdc Amps (Current Transducer) P-Option* Amps (Current Transducer) 5A 0–5 A 0–10 A 20 A 250 A 0.25 VA (maximum) at 5 A 5A 0–5 A 0–6 A 20 A 250 A 0.25 VA (maximum) at 5 A N/A N/A 120 V 0–150 V 0–150 V 180 V 2.2 VA (maximum) at 120 V N/A 0–1 mAdc Volts (Voltage Transducer) Specifications P-Option* Volts (Voltage Transducer) Voltage Input N/A 0–1 mAdc Volts (Expanded-Scale Voltage Transducer) 120 V 0–150 V 0–165 V 180 V 2.2 VA (maximum) at 120 V 100–130 Vac 50–500 Hz 3 VA Nominal None Required None Required 100–130 Vac 50–500 Hz 3 VA Nominal 0 mAdc at low end of range (customer specified) 1 mAdc at high end of range (customer specified) 1 or 4 mAdc at low end of range (customer specified) 5 or 20 mAdc at high end of range (customer specified) ±0.25% of Input Voltage for 60 Hz Accuracy Temperature Effect on Accuracy ±0.007% / ° C ±0.01% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C 10 Vdc 25 Vdc Load 0–10,000 Ω 0–5,000 Ω for 1–5 mAdc units 0–1,250 Ω for 4–20 mAdc units Output Ripple Peak < 2.5% RO < 2.5% of Span Compliance Voltage Rated Output (RO) = 5 A or 150 V/Element 1 mAdc for Standard Calibration Accuracy Standard A4 Models ±0.25% RO ±0.1% RO ± 0.25% of Span ±0.25% RO ±0.1% RO ± 0.25% of Span Temperature Effect on Accuracy ± 0.01% / ° C ± 0.015% / ° C ±0.01% / ° C ±0.015% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc 25 Vdc 10 Vdc 25 Vdc Frequency Range 55–65 Hz Stability (per year) ± 0.25% of Input Voltage, Noncumulative 1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* Load 0–10,000 Ω 0–5,000 W for 1–5 mAdc units 0–1,250 W for 4–20 mAdc units 0–10,000 Ω 0–5,000 W for 1–5 mAdc units 0–1,250 W for 4–20 mAdc units Output Ripple Peak < 0.25% RO < 0.25% of Span < 0.25% RO < 0.25% of Span Response Time Standard Calibration Adjustments < 400 ms to 99% Gain Zero 50–500 Hz (specify nominal) ±0.1% RO, Noncumulative Stability (per year) ±0.15% of Span, Noncumulative Operating Humidity ± 0.25% RO, Noncumulative ± 0.3% of Span, Noncumulative ±20% of Span ±5% of Span 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Case) Surge Withstand Maximum Net Weight Approximate Dimensions * P-Option includes 1–5 and 4–20 mAdc outputs. **Minimum span must be at least 18% of low-end voltage. Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Weights vary by model; consult factory. See enclosure diagrams on page 85. Specifications subject to change without notice. 0–95% Noncondensing Isolation Complete (Input/Output/Case) Complete (Input/Output/Power/Case) Dielectric Withstand Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight Weights vary by model; consult factory. Approximate Dimensions See enclosure diagrams on page 85. *P-Option includes 1–5 and 4–20 mAdc outputs. Not available on all models. AMETEK® Power Instruments 255 North Union Street Specifications subject to change without notice. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 82 SCI Transducer Cat. 52-89(MTD) < 400 ms to 99% ±5% of Span ±5% of Span Gain Zero Dielectric Withstand ± 10% of Reading (minimum) ±20% of Span (minimum) ± 10% of Reading (minimum) ±20% of Span (minimum) None Required None Required ±5% of Zero Point (minimum) ±5% of Zero Point (minimum) Frequency Range Response Time Standard Calibration Adjustments XLP Plug-In Compliance Voltage 5 or 20 mAdc for Std. Calibration, depending on selected output range* Rated Output (RO) P-Option* Volts (Expanded-Scale Voltage Transducer) Any 20–60 V span between 90–150 V (customer specified)** 150 V 2 VA (maximum) at 120 V Span/Range Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden 100–130 Vac 50–500 Hz 3 VA Nominal None Required Specifications Exceltronic XLP AC ExpandedScale Voltage Transducers 83 82-83 1/9/02, 5:29 PM Specifications Exceltronic XLP Combined AC Watt/Var Transducers Specifications Exceltronic XLP AC Watt or Var Transducers 0 to ±1 mAdc Watts (Watt Transducer) Specifications 0 to ±1 mAdc Vars (Var Transducer) P-Option* Watts (Watt Transducer) Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A Voltage Input Nominal Range** Overload Continuous Burden/Element 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal Rated Output (RO) = 500 Watts or Vars/Element ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±(0.2% Reading + 0.01% RO) ±(0.2% Reading + 0.05% RO) ±(0.2% Reading + 0.02% RO) ±(0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy ± 0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc 25 Vdc 10 Vdc 25 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units Output Ripple Peak Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A Voltage Input Nominal Range** Overload Continuous Burden/Element 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Power Factor PF Effect on Accuracy Gain Zero ±0.1% VA (maximum) ±0.15% VA (maximum) ± 2% of Reading (minimum) ±20% of Span (minimum) ±5% of Zero Point (minimum) None Required ± 2% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) Frequency Range 58–62 Hz ±0.1% RO, Noncumulative Stability (per year) Operating Humidity 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 7 VA Nominal ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±(0.2% Reading + 0.01% RO) ±(0.2% Reading + 0.05% RO) ±(0.2% Reading + 0.02% RO) ±(0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy Temperature Effect on Accuracy ±0.005% / ° C ± 0.0075% / ° C ± 0.009% / ° C ± 0.012% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage Load 10 Vdc 25 Vdc 10 Vdc 25 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units 60 Hz ±0.15% of Span, Noncumulative < 0.5% RO ± 0.2% RO, Noncumulative ±0.25% of Span, Noncumulative < 400 ms to 99% Power Factor Any PF Effect on Accuracy Standard Calibration Adjustments Gain Zero 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Approximate Dimensions 500–1000 Watts/Element 500–600 Watts/Element Stability (per year) 60 Hz ±0.1% RO, Noncumulative 500–1000 Vars/Element Specifications subject to change without notice. ±0.25% of Span, Noncumulative 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Weights vary by model; consult factory. See enclosure diagrams on page 85. Approximate Dimensions Overrange with Linearity ±0.2% RO, Noncumulative 0–95% Noncondensing Maximum Net Weight 500–600 Vars/Element ± 0.15% of Span, Noncumulative Complete (Input/Output/Power/Case) Surge Withstand No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5 and 4–20/4–12–20 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. ±2% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) Dielectric Withstand See enclosure diagrams on page 85. Overrange with Linearity ±2% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) Isolation Weights vary by model; consult factory. Maximum Net Weight ±0.15% VA (maximum) Operating Humidity Complete (Input/Output/Power/Case) Dielectric Withstand ±0.1% VA (maximum) Frequency 0–95% Noncondensing Isolation 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5 and 4–20/4–12–20 mAdc outputs. Not available on XLPWV10-30 model. **Total input not to exceed 200% of standard-calibration watts and vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts and vars on units with P-Option outputs. AMETEK® Power Instruments 84 SCI Transducer Cat. 52-89(MTD) 100–130 Vac 50–500 Hz 7 VA Nominal Response Time Any P-Option* Vars (Combined Watt/Var Transducer) 85–135 Vac 50–500 Hz 3 VA Nominal Output Ripple Peak < 400 ms to 99% 0 to ±1 mAdc Vars (Combined Watt/Var Transducer) P-Option* Watts (Combined Watt/Var Transducer) Current Input < 0.5% RO Response Time Standard Calibration Adjustments 0 to ±1 mAdc Watts (Combined Watt/Var Transducer) XLP Plug-In Temperature Effect on Accuracy Load Specifications P-Option* Vars (Var Transducer) 255 North Union Street Rochester, New York 14605 Specifications subject to change without notice. Phone: 1-800-274-5368 Fax: 585-454-7805 85 84-85 1/9/02, 5:29 PM Specifications Exceltronic XLP Combined AC Watt/Var Transducers Specifications Exceltronic XLP AC Watt or Var Transducers 0 to ±1 mAdc Watts (Watt Transducer) Specifications 0 to ±1 mAdc Vars (Var Transducer) P-Option* Watts (Watt Transducer) Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A Voltage Input Nominal Range** Overload Continuous Burden/Element 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 5 VA Nominal Rated Output (RO) = 500 Watts or Vars/Element ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±(0.2% Reading + 0.01% RO) ±(0.2% Reading + 0.05% RO) ±(0.2% Reading + 0.02% RO) ±(0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy ± 0.005% / ° C ±0.0075% / ° C ±0.009% / ° C ±0.012% / ° C Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage 10 Vdc 25 Vdc 10 Vdc 25 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units Output Ripple Peak Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 20 A 250 A 0.2 VA (maximum) at 5 A Voltage Input Nominal Range** Overload Continuous Burden/Element 120 V 0–150 V 200 V 0.02 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden Rated Output (RO) = 500 Watts or Vars/Element Power Factor PF Effect on Accuracy Gain Zero ±0.1% VA (maximum) ±0.15% VA (maximum) ± 2% of Reading (minimum) ±20% of Span (minimum) ±5% of Zero Point (minimum) None Required ± 2% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) Frequency Range 58–62 Hz ±0.1% RO, Noncumulative Stability (per year) Operating Humidity 85–135 Vac 50–500 Hz 3 VA Nominal 100–130 Vac 50–500 Hz 7 VA Nominal ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* ±(0.2% Reading + 0.01% RO) ±(0.2% Reading + 0.05% RO) ±(0.2% Reading + 0.02% RO) ±(0.3% Reading + 0.05% RO) at 0–120% RO at 0–200% RO at 0–120% RO at 0–200% RO Accuracy Temperature Effect on Accuracy ±0.005% / ° C ± 0.0075% / ° C ± 0.009% / ° C ± 0.012% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage Load 10 Vdc 25 Vdc 10 Vdc 25 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units 0–10,000 Ω 0–5,000 Ω for 1–5/1–3–5 mAdc units 0–1,250 Ω for 4–20/4–12–20 mAdc units < 0.5% RO 60 Hz ±0.15% of Span, Noncumulative ±0.25% of Span, Noncumulative ± 0.2% RO, Noncumulative < 400 ms to 99% Power Factor Any PF Effect on Accuracy Standard Calibration Adjustments Gain Zero 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Approximate Dimensions 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element Stability (per year) AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 60 Hz ±0.1% RO, Noncumulative Specifications subject to change without notice. Phone: 1-800-274-5368 ±0.25% of Span, Noncumulative 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Weights vary by model; consult factory. See enclosure diagrams on page 85. Approximate Dimensions Overrange with Linearity ±0.2% RO, Noncumulative 0–95% Noncondensing Maximum Net Weight 500–600 Vars/Element ± 0.15% of Span, Noncumulative Complete (Input/Output/Power/Case) Surge Withstand No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5 and 4–20/4–12–20 mAdc outputs. **Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with P-Option outputs. ±2% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) Dielectric Withstand See enclosure diagrams on page 85. Overrange with Linearity ±2% of Reading (minimum) ±20% of Span (minimum) None Required ±5% of Zero Point (minimum) Isolation Weights vary by model; consult factory. Maximum Net Weight ±0.15% VA (maximum) Operating Humidity Complete (Input/Output/Power/Case) Dielectric Withstand ±0.1% VA (maximum) Frequency 0–95% Noncondensing Isolation 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. * P-Option includes 1–5/1–3–5 and 4–20/4–12–20 mAdc outputs. Not available on XLPWV10-30 model. **Total input not to exceed 200% of standard-calibration watts and vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts and vars on units with P-Option outputs. Specifications subject to change without notice. Fax: 585-454-7805 84 SCI Transducer Cat. 52-89(MTD) 100–130 Vac 50–500 Hz 7 VA Nominal Response Time Any P-Option* Vars (Combined Watt/Var Transducer) 85–135 Vac 50–500 Hz 3 VA Nominal Output Ripple Peak < 400 ms to 99% 0 to ±1 mAdc Vars (Combined Watt/Var Transducer) P-Option* Watts (Combined Watt/Var Transducer) Current Input < 0.5% RO Response Time Standard Calibration Adjustments 0 to ±1 mAdc Watts (Combined Watt/Var Transducer) XLP Plug-In Temperature Effect on Accuracy Load Specifications P-Option* Vars (Var Transducer) 85 84-85 1/9/02, 5:29 PM Specifications Exceltronic XLP AC Phase Angle or Voltage Angle Transducers 0 to ±1 mAdc (Phase Angle Transducer) Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element Second Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden 5A 0.5–5 A 10 A 250 A 0.2 VA (maximum) at 5 A None Required 100–130 Vac 50–500 Hz 2 VA Nominal None Required ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* Temperature Effect on Accuracy Operating Temperature Range Compliance Voltage Load ± 0.5° -20° C to +60° C ± 0.6° ±0.5° -20° C to +50° C ±0.6° -20° C to +60° C -20° C to +50° C 10 Vdc 25 Vdc 10 Vdc 25 Vdc 0–5,000 Ω for 1–3–5 mAdc units 0–1,250 Ω for 4–12–20 mAdc units 0–10,000 Ω 0–5,000 Ω for 1–3–5 mAdc units 0–1,250 Ω for 4–12–20 mAdc units < 1% RO Response Time ±3% of Reading (minimum) ±20% of Span (minimum) ± 2% RO (minimum) ±5% of Zero Point (minimum) ± 0.02% of Center Frequency at 25° C ± 0.005% of Center Frequency at 25° C ± 0.0025% / ° C ± 0.005% / ° C Operating Temperature Range -20° C to +60° C -20° C to +50° C 10 Vdc 25 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5 mAdc units 0–1,250 Ω for 4–20 mAdc units Compliance Voltage Load Output Ripple Peak < 1% RO < 1% of Span Response Time < 400 ms to 99% Gain Zero ±5% of Span (minimum) ±10% of Span (minimum) ± 20% of Span (minimum) ±5% of Zero Point (minimum) ±0.02% of Center Frequency ±0.04% of Center Frequency 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Case) Dielectric Withstand Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight Weights vary by model; consult factory. Approximate Dimensions See enclosure diagrams on page 85. Specifications subject to change without notice. ±3% of Reading (minimum) ±20% of Span (minimum) ±2% RO (minimum) ±5% of Zero Point (minimum) Nominal ± 3% Frequency ±1% RO, Noncumulative Stability (per year) Operating Humidity ± 1% of Span, Noncumulative ± 1% RO, Noncumulative ±1% of Span, Noncumulative 0–95% Noncondensing Isolation Complete (Input/Output/Case) Dielectric Withstand Complete (Input/Output/Power/Case) Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Surge Withstand Weights vary by model; consult factory. Maximum Net Weight Approximate Dimensions See enclosure diagrams on page 85. *P-Option includes 1–3–5 and 4–12–20 mAdc outputs. Specifications subject to change without notice. AMETEK® Power Instruments 86 SCI Transducer Cat. 52-89(MTD) 5 or 20 mAdc for Standard Calibration, depending on selected output range* *P-Option includes 1–5 and 4–20 mAdc outputs. < 400 ms to 99% Gain Zero 1 mAdc at Maximum Rated Frequency Temperature Effect on Accuracy Stability (per year) 0–10,000 Ω Output Ripple Peak Accuracy Standard Calibration Adjustments 0 to ± 45°, 0 to ±60°, 0 to ±75°, and 0 to ±180° 100–130 Vac 50–500 Hz 2 VA Nominal None Required XLP Plug-In 5 or 20 mAdc for Std. Calibration, depending on selected output range* 100–130 Vac 50–500 Hz 2 VA Nominal P-Option* (Frequency Transducer) 120 V 90–150 V 150 V 2 VA (maximum) at 120 V Nominal Range Overload Continuous Burden/Element Rated Output (RO) ±1° at 25° C Phase Angle Range (without ambiguous readings) Voltage Input External Input Range Auxiliary Frequency Range Power Burden 120 V 50–135 V 150 V 2.2 VA (maximum) at 120 V N/A 0–1 mAdc (Frequency Transducer) Specifications N/A Accuracy Standard Calibration Adjustments P-Option* (Voltage Angle Transducer) 120 V 95–135 V 150 V 4 VA (maximum) at 120 V ±1 mAdc for Standard Calibration Rated Output (RO) 0 to ±1 mAdc (Voltage Angle Transducer) P-Option* (Phase Angle Transducer) Specifications Exceltronic XLP AC Frequency Transducers 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 87 86-87 1/9/02, 5:29 PM Specifications Exceltronic XLP AC Phase Angle or Voltage Angle Transducers 0 to ±1 mAdc (Phase Angle Transducer) Specifications Current Input Nominal Range** Overload Continuous Overload 1 Second/Hour Burden/Element Voltage Input Nominal Range** Overload Continuous Burden/Element Second Voltage Input Nominal Range** Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden 5A 0.5–5 A 10 A 250 A 0.2 VA (maximum) at 5 A 100–130 Vac 50–500 Hz 2 VA Nominal 100–130 Vac 50–500 Hz 2 VA Nominal None Required ±1 mAdc for Standard Calibration 5 or 20 mAdc for Std. Calibration, depending on selected output range* Temperature Effect on Accuracy Operating Temperature Range Compliance Voltage Load -20° C to +60° C ± 0.6° -20° C to +50° C ±0.6° -20° C to +60° C -20° C to +50° C 10 Vdc 25 Vdc 10 Vdc 25 Vdc 0–10,000 Ω 0–5,000 Ω for 1–3–5 mAdc units 0–1,250 Ω for 4–12–20 mAdc units 0–10,000 Ω 0–5,000 Ω for 1–3–5 mAdc units 0–1,250 Ω for 4–12–20 mAdc units < 1% RO Output Ripple Peak Response Time Gain Zero ±3% of Reading (minimum) ±20% of Span (minimum) ± 2% RO (minimum) ±5% of Zero Point (minimum) 5 or 20 mAdc for Standard Calibration, depending on selected output range* ± 0.02% of Center Frequency at 25° C ± 0.005% of Center Frequency at 25° C ± 0.0025% / ° C ± 0.005% / ° C -20° C to +50° C 10 Vdc 25 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5 mAdc units 0–1,250 Ω for 4–20 mAdc units Compliance Voltage Load Output Ripple Peak < 1% RO < 1% of Span Response Time < 400 ms to 99% Gain Zero ±5% of Span (minimum) ±10% of Span (minimum) ± 20% of Span (minimum) ±5% of Zero Point (minimum) ±0.02% of Center Frequency ±0.04% of Center Frequency 0–95% Noncondensing Operating Humidity Isolation Dielectric Withstand Surge Withstand Maximum Net Weight Approximate Dimensions Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Weights vary by model; consult factory. See enclosure diagrams on page 85. Specifications subject to change without notice. ±3% of Reading (minimum) ±20% of Span (minimum) ±2% RO (minimum) ±5% of Zero Point (minimum) Nominal ± 3% Frequency ±1% RO, Noncumulative Stability (per year) Operating Humidity ± 1% of Span, Noncumulative ± 1% RO, Noncumulative ±1% of Span, Noncumulative 0–95% Noncondensing Isolation Complete (Input/Output/Case) Dielectric Withstand Complete (Input/Output/Power/Case) Complete (Input/Output/Case) Complete (Input/Output/Power/Case) 1500 VRMS at 60 Hz ANSI/IEEE C37.90.1 Surge Withstand Weights vary by model; consult factory. Maximum Net Weight Approximate Dimensions See enclosure diagrams on page 85. *P-Option includes 1–3–5 and 4–12–20 mAdc outputs. AMETEK® Power Instruments 255 North Union Street Specifications subject to change without notice. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 86 SCI Transducer Cat. 52-89(MTD) 1 mAdc at Maximum Rated Frequency -20° C to +60° C *P-Option includes 1–5 and 4–20 mAdc outputs. < 400 ms to 99% 100–130 Vac 50–500 Hz 2 VA Nominal None Required Operating Temperature Range Stability (per year) ±0.5° 120 V 90–150 V 150 V 2 VA (maximum) at 120 V Temperature Effect on Accuracy Standard Calibration Adjustments 0 to ± 45°, 0 to ±60°, 0 to ±75°, and 0 to ±180° ± 0.5° Accuracy P-Option* (Frequency Transducer) XLP Plug-In 5 or 20 mAdc for Std. Calibration, depending on selected output range* 0–1 mAdc (Frequency Transducer) Nominal Range Overload Continuous Burden/Element Rated Output (RO) ±1° at 25° C Phase Angle Range (without ambiguous readings) Voltage Input External Input Range Auxiliary Frequency Range Power Burden 120 V 50–135 V 150 V 2.2 VA (maximum) at 120 V N/A None Required Specifications N/A Accuracy Standard Calibration Adjustments P-Option* (Voltage Angle Transducer) 120 V 95–135 V 150 V 4 VA (maximum) at 120 V ±1 mAdc for Standard Calibration Rated Output (RO) 0 to ±1 mAdc (Voltage Angle Transducer) P-Option* (Phase Angle Transducer) Specifications Exceltronic XLP AC Frequency Transducers 87 86-87 1/9/02, 5:29 PM Enclosure Drawings Exceltronic XLP Modular Plug-In Transducers Specifications Exceltronic XLP Temperature Transducers ENCLOSURE DRAWINGS Specifications External Input Range Auxiliary Frequency Range Burden Power Rated Output (RO) 0–1 mAdc (Temperature Transducer) P-Option* (Temperature Transducer) 90–130 Vac 50–500 Hz 3.5 VA Nominal 100–130 Vac 50–500 Hz 5.5 VA Nominal 1 mAdc at Maximum Calibrated Temperature 5 or 20 mAdc for Standard Calibration, depending on selected output range* Accuracy Nickel-Iron Platinum Copper ± 0.015% / ° F ± 0.017% / ° F Operating Temperature Range -20° C to +60° C (-4° F to +140° F) -20° C to +50° C (-4° F to +122° F) Compliance Voltage 10 Vdc 25 Vdc Open Circuit Voltage 16 Vdc 30 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5 mAdc units 0–1,250 Ω for 4–20 mAdc units Load Output Ripple Peak < 1% RO < 1% of Span Response Time 4-Module Enclosure 6.57" (166.89 mm) 5.82" (147.83 mm) 0.8% of Span 0.5% of Span 0.8% of Span Temperature Effect on Accuracy Standard Calibration Adjustments 2-Module Enclosure 10.70" (271.78 mm) 9.94" (252.48 mm) 4.00" (101.60 mm) 4.52" MAX. (114.81 mm) 7.00" (177.80 mm) 7.00" 4.00" (101.60 mm) (177.80 mm) 1.50" (38.10 mm) 8.65" MAX. (219.71 mm) 1.50" (38.10 mm) (WIDTH BEHIND FRONT) (WIDTH BEHIND FRONT) < 50 ms to 99% Gain Zero Stability (per year) Operating Humidity ± 5% of Span (minimum) ± 3% of Span (minimum) ±20% of Span (minimum) ± 5% of Zero Point (minimum) ±0.4% RO, Noncumulative ±0.5% of Span, Noncumulative 8-Module Enclosure (front view) 0–95% Noncondensing Isolation Input/Power/Case and Output/Power/Case Dielectric Withstand 1500 VRMS at 60 Hz Surge Withstand Maximum Net Weight Approximate Dimensions ANSI/IEEE C37.90.1 18.95" (481.33 mm) Weights vary by model; consult factory. 18.19" (462.03 mm) See enclosure diagrams on page 85. *P-Option includes 1–5 and 4–20 mAdc outputs. Specifications subject to change without notice. Instrumentation 4.00" 7.00" (101.60 mm) (177.80 mm) 16.90" MAX. (429.26 mm) (WIDTH BEHIND FRONT) Enclosure Module (side view) 1.50" (38.10 mm) FRONT OF MODULE 0.061" (1.55 mm) BEHIND THIS LINE 11.65" (295.91 mm) 0.126" (3.20 mm) 1.19" (30.23 mm) AMETEK® Power Instruments 88 SCI Transducer Cat. 52-89(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 89 88-89 1/9/02, 5:29 PM Enclosure Drawings Exceltronic XLP Modular Plug-In Transducers Specifications Exceltronic XLP Temperature Transducers ENCLOSURE DRAWINGS Specifications External Input Range Auxiliary Frequency Range Burden Power Rated Output (RO) 0–1 mAdc (Temperature Transducer) P-Option* (Temperature Transducer) 90–130 Vac 50–500 Hz 3.5 VA Nominal 100–130 Vac 50–500 Hz 5.5 VA Nominal 1 mAdc at Maximum Calibrated Temperature 5 or 20 mAdc for Standard Calibration, depending on selected output range* Accuracy Nickel-Iron Platinum Copper ± 0.015% / ° F ± 0.017% / ° F Operating Temperature Range -20° C to +60° C (-4° F to +140° F) -20° C to +50° C (-4° F to +122° F) Compliance Voltage 10 Vdc 25 Vdc Open Circuit Voltage 16 Vdc 30 Vdc 0–10,000 Ω 0–5,000 Ω for 1–5 mAdc units 0–1,250 Ω for 4–20 mAdc units Load Output Ripple Peak < 1% RO < 1% of Span Response Time 4-Module Enclosure 6.57" (166.89 mm) 5.82" (147.83 mm) 0.8% of Span 0.5% of Span 0.8% of Span Temperature Effect on Accuracy Standard Calibration Adjustments 2-Module Enclosure 10.70" (271.78 mm) 9.94" (252.48 mm) 4.00" (101.60 mm) 4.52" MAX. (114.81 mm) 7.00" (177.80 mm) 7.00" 4.00" (101.60 mm) (177.80 mm) 1.50" (38.10 mm) 8.65" MAX. (219.71 mm) 1.50" (38.10 mm) (WIDTH BEHIND FRONT) (WIDTH BEHIND FRONT) < 50 ms to 99% Gain Zero Stability (per year) ± 5% of Span (minimum) ± 3% of Span (minimum) ±20% of Span (minimum) ± 5% of Zero Point (minimum) ±0.4% RO, Noncumulative ±0.5% of Span, Noncumulative Operating Humidity 8-Module Enclosure (front view) 0–95% Noncondensing Isolation Input/Power/Case and Output/Power/Case Dielectric Withstand 1500 VRMS at 60 Hz Surge Withstand Maximum Net Weight Approximate Dimensions ANSI/IEEE C37.90.1 18.95" (481.33 mm) Weights vary by model; consult factory. 18.19" (462.03 mm) See enclosure diagrams on page 85. *P-Option includes 1–5 and 4–20 mAdc outputs. Specifications subject to change without notice. 16.90" MAX. (429.26 mm) (WIDTH BEHIND FRONT) Enclosure Module (side view) 1.50" (38.10 mm) Instrumentation 4.00" 7.00" (101.60 mm) (177.80 mm) FRONT OF MODULE 0.061" (1.55 mm) BEHIND THIS LINE 11.65" (295.91 mm) 0.126" (3.20 mm) 1.19" (30.23 mm) AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 88 SCI Transducer Cat. 52-89(MTD) 89 88-89 1/9/02, 5:29 PM Ordering Procedure Exceltronic XLP Modular Plug-In Transducers Ordering Procedure Exceltronic XLP Modular Plug-In Transducers ORDERING PROCEDURE Table 2 Watt or Var Base Model Numbers Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. WATT OR VAR TRANSDUCERS IN ONE PLUG-IN MODULE Base Model No. Output Option #1 Option #2 Tables 1 thru 5 Table 6 Table 7 Table 7 A2 -FA Watt Model No. XLPW10 XLPW15 XLPW20 XLPW25 XLPW30 External Aux. Power 0 to ±1 mAdc output XLPWV20 Var Model No. XLPV10 XLPV15 XLPV20 XLPV25 XLPV30 Description 1-Element Watt 11/2-Element Watt 2-Element Watt 21/2-Element Watt 3-Element Watt COMBINED WATT/VAR TRANSDUCERS IN ONE PLUG-IN MODULE Description 1-Element Var 11/2-Element Var 2-Element Var 21/2-Element Var 3-Element Var Combined Watt/ Var Model No. XLPWV10 XLPWV15 XLPWV20 XLPWV25 XLPWV30 XLPWV10-30* Description 1-Element Watt/Var 11/2-Element Watt/Var 2-Element Watt/Var 21/2-Element Watt/Var 3-Element Watt/Var Three 1-Element Watt/Vars * Not available with 1-5 or 4-20 mAdc outputs. P-Option outputs EXAMPLES: P7-B Most XLP units have internal aux. power. Select A2 for external aux. power (120 Vac std.). If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. XLPWV20A2-FA 2-element, 0 to ±1 mAdc Watt/Var Plug-In Transducer; 120 Vac external auxiliary power; front access. XLPWV20P7-BA2-FA 2-element, 4-12-20 mAdc Watt/Var Plug-In Transducer; 120 Vac external auxiliary power; front access. You must specify a model number for each module position in the bin (l-r). Specify unused positions as either "blank" or "empty". 8-Position Bin 4-Position Bin 2-Position Bin Quantity of Blanks 10093-001K 10387-001K 10386-001K 10184-001 Table 1 Current or Voltage Base Model Numbers COMBINED CURRENT/VOLTAGE TRANSDUCERS IN ONE PLUG-IN MODULE Current Model No. XLPC XLPC2 XLPC3 Description One Current Unit Two Current Units Three Current Units Voltage Model No. XLPE XLPE2 XLPE3 XLPE4* Description One Voltage Unit Two Voltage Units Three Voltage Units Four Voltage Units Combined Current/ Voltage Model No. XLPCE XLPC2E XLPC3E* XLPCE2 XLPCE3* XLPCE4* XLPC2E2* XLPC2E3* XLPC2E4* XLPC3E2* XLPC3E3* Description One Voltage Unit (with 90-150 V expanded-scale option) Two Voltage Units (with 90-150 V expanded-scale option) Three Voltage Units (with 90-150 V expanded-scale option) XLPEX2 XLPEX3 ONE OR TWO VOLTAGE ANGLE TRANSDUCERS IN ONE PLUG-IN MODULE Phase Angle Model No. XLPF1-45 XLPF1-60 XLPF1-75 XLPF1-180 XLPF2-45 XLPF2-60 XLPF2-75 XLPF2-180 Voltage Angle Model No. XLPA1-45 XLPA1-60 XLPA1-75 XLPA1-180 XLPA2-45 XLPA2-60 XLPA2-75 XLPA2-180 Description One Current Unit/One Voltage Unit Two Current Units/One Voltage Unit Three Current Units/One Voltage Unit One Current Unit/Two Voltage Units One Current Unit/Three Voltage Units One Current Unit/Four Voltage Units Two Current Units/Two Voltage Units Two Current Units/Three Voltage Units Two Current Units/Four Voltage Units Three Current Units/Two Voltage Units Three Current Units/Three Voltage Units * Not available with 1-5 or 4-20 mAdc outputs. Description One 45° Voltage Angle Unit One 60° Voltage Angle Unit One 75° Voltage Angle Unit One 180° Voltage Angle Unit Two 45° Voltage Angle Units Two 60° Voltage Angle Units Two 75° Voltage Angle Units Two 180° Voltage Angle Units Table 4 Frequency Base Model Numbers Table 5 Temperature Base Model Numbers ONE OR TWO FREQUENCY TRANSDUCERS IN ONE PLUG-IN MODULE ONE OR TWO TEMPERATURE TRANSDUCERS IN ONE PLUG-IN MODULE Frequency Model No. XLPZ150 XLPZ160 XLPZ1400 XLPZ250 XLPZ260 XLPZ2400 Description One 50 Hz Frequency Unit One 60 Hz Frequency Unit One 400 Hz Frequency Unit Two 50 Hz Frequency Units Two 60 Hz Frequency Units Two 400 Hz Frequency Units 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Temperature Model No. XLP15 XLP16 XLP19 XLP25 XLP26 XLP29 Description One Nickel-Iron Temperature Unit One Platinum Temperature Unit One Copper Temperature Unit Two Nickel-Iron Temperature Units Two Platinum Temperature Units Two Copper Temperature Units See Table 1 on page 74 for additional ordering information. P-Option P6** P7** P6-B*** P7-B*** Output Range 1-5 mAdc 4-20 mAdc 1-3-5 mAdc 4-12-20 mAdc Compliance Voltage 25 Vdc 25 Vdc 25 Vdc 25 Vdc Maximum Load 5000 Ω 1250 Ω 5000 Ω 1250 Ω Max. Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 30 Vdc ** P6 and P7 options are available for all XLP types except Phase Angle and Voltage Angle. *** P6-B and P7-B options are available for all XLP types except Current, Voltage, Frequency, and Temperature. Table 7 Options Option -1 -5 A2**** -FA Description 240 V Input 10 A Input External Auxiliary Power (120 Vac std.) Front Access **** Most XLP transducers come standard with internal auxiliary power (A4 option). If you require external auxiliary power, the A2 option designator should come before any other options in the complete model number. If you require additional options not shown here, please consult the factory. Combined Watt/Watthour or Var/Varhour and Combined Phase/Voltage Angle transducers are available in XLP format on special order. Please consult the factory for more information. 90 SCI Transducer Cat 90-134(MTD) Description One 45° Phase Angle Unit One 60° Phase Angle Unit One 75° Phase Angle Unit One 180° Phase Angle Unit Two 45° Phase Angle Units Two 60° Phase Angle Units Two 75° Phase Angle Units Two 180° Phase Angle Units Table 6 Output Selection CURRENT OR VOLTAGE TRANSDUCERS IN ONE PLUG-IN MODULE Expanded-Scale Voltage Model No. XLPEX ONE OR TWO PHASE ANGLE TRANSDUCERS IN ONE PLUG-IN MODULE Instrumentation Position 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 Position 8 You must specify the size of enclosure and quantity of blank modules (if required). This information is not part of the model number, but must be provided to the factory when you place your order. Delete the "K" from the part numbers below if you do not want the factory to assemble your enclosure. Table 3 Phase Angle or Voltage Angle Base Model Numbers 91 90-91 1/9/02, 5:32 PM Ordering Procedure Exceltronic XLP Modular Plug-In Transducers Ordering Procedure Exceltronic XLP Modular Plug-In Transducers ORDERING PROCEDURE Table 2 Watt or Var Base Model Numbers Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. WATT OR VAR TRANSDUCERS IN ONE PLUG-IN MODULE Base Model No. Output Option #1 Option #2 Tables 1 thru 5 Table 6 Table 7 Table 7 A2 -FA Watt Model No. XLPW10 XLPW15 XLPW20 XLPW25 XLPW30 External Aux. Power 0 to ±1 mAdc output XLPWV20 Var Model No. XLPV10 XLPV15 XLPV20 XLPV25 XLPV30 Description 1-Element Watt 11/2-Element Watt 2-Element Watt 21/2-Element Watt 3-Element Watt COMBINED WATT/VAR TRANSDUCERS IN ONE PLUG-IN MODULE Description 1-Element Var 11/2-Element Var 2-Element Var 21/2-Element Var 3-Element Var Combined Watt/ Var Model No. XLPWV10 XLPWV15 XLPWV20 XLPWV25 XLPWV30 XLPWV10-30* Description 1-Element Watt/Var 11/2-Element Watt/Var 2-Element Watt/Var 21/2-Element Watt/Var 3-Element Watt/Var Three 1-Element Watt/Vars * Not available with 1-5 or 4-20 mAdc outputs. P-Option outputs EXAMPLES: P7-B Most XLP units have internal aux. power. Select A2 for external aux. power (120 Vac std.). If other than 120 Vac (std.), specify ext. aux. power voltage: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. XLPWV20A2-FA 2-element, 0 to ±1 mAdc Watt/Var Plug-In Transducer; 120 Vac external auxiliary power; front access. XLPWV20P7-BA2-FA 2-element, 4-12-20 mAdc Watt/Var Plug-In Transducer; 120 Vac external auxiliary power; front access. You must specify a model number for each module position in the bin (l-r). Specify unused positions as either "blank" or "empty". 8-Position Bin 4-Position Bin 2-Position Bin Quantity of Blanks 10093-001K 10387-001K 10386-001K 10184-001 Table 1 Current or Voltage Base Model Numbers COMBINED CURRENT/VOLTAGE TRANSDUCERS IN ONE PLUG-IN MODULE Current Model No. XLPC XLPC2 XLPC3 Description One Current Unit Two Current Units Three Current Units Voltage Model No. XLPE XLPE2 XLPE3 XLPE4* Description One Voltage Unit Two Voltage Units Three Voltage Units Four Voltage Units Combined Current/ Voltage Model No. XLPCE XLPC2E XLPC3E* XLPCE2 XLPCE3* XLPCE4* XLPC2E2* XLPC2E3* XLPC2E4* XLPC3E2* XLPC3E3* Description One Voltage Unit (with 90-150 V expanded-scale option) Two Voltage Units (with 90-150 V expanded-scale option) Three Voltage Units (with 90-150 V expanded-scale option) XLPEX2 XLPEX3 AMETEK® Power Instruments 255 North Union Street ONE OR TWO VOLTAGE ANGLE TRANSDUCERS IN ONE PLUG-IN MODULE Phase Angle Model No. XLPF1-45 XLPF1-60 XLPF1-75 XLPF1-180 XLPF2-45 XLPF2-60 XLPF2-75 XLPF2-180 Voltage Angle Model No. XLPA1-45 XLPA1-60 XLPA1-75 XLPA1-180 XLPA2-45 XLPA2-60 XLPA2-75 XLPA2-180 Rochester, New York 14605 Description One Current Unit/One Voltage Unit Two Current Units/One Voltage Unit Three Current Units/One Voltage Unit One Current Unit/Two Voltage Units One Current Unit/Three Voltage Units One Current Unit/Four Voltage Units Two Current Units/Two Voltage Units Two Current Units/Three Voltage Units Two Current Units/Four Voltage Units Three Current Units/Two Voltage Units Three Current Units/Three Voltage Units * Not available with 1-5 or 4-20 mAdc outputs. Phone: 1-800-274-5368 Description One 45° Voltage Angle Unit One 60° Voltage Angle Unit One 75° Voltage Angle Unit One 180° Voltage Angle Unit Two 45° Voltage Angle Units Two 60° Voltage Angle Units Two 75° Voltage Angle Units Two 180° Voltage Angle Units Table 4 Frequency Base Model Numbers Table 5 Temperature Base Model Numbers ONE OR TWO FREQUENCY TRANSDUCERS IN ONE PLUG-IN MODULE ONE OR TWO TEMPERATURE TRANSDUCERS IN ONE PLUG-IN MODULE Frequency Model No. XLPZ150 XLPZ160 XLPZ1400 XLPZ250 XLPZ260 XLPZ2400 Description One 50 Hz Frequency Unit One 60 Hz Frequency Unit One 400 Hz Frequency Unit Two 50 Hz Frequency Units Two 60 Hz Frequency Units Two 400 Hz Frequency Units 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. Temperature Model No. XLP15 XLP16 XLP19 XLP25 XLP26 XLP29 Description One Nickel-Iron Temperature Unit One Platinum Temperature Unit One Copper Temperature Unit Two Nickel-Iron Temperature Units Two Platinum Temperature Units Two Copper Temperature Units See Table 1 on page 74 for additional ordering information. P-Option P6** P7** P6-B*** P7-B*** Output Range 1-5 mAdc 4-20 mAdc 1-3-5 mAdc 4-12-20 mAdc Compliance Voltage 25 Vdc 25 Vdc 25 Vdc 25 Vdc Maximum Load 5000 Ω 1250 Ω 5000 Ω 1250 Ω Max. Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 30 Vdc ** P6 and P7 options are available for all XLP types except Phase Angle and Voltage Angle. *** P6-B and P7-B options are available for all XLP types except Current, Voltage, Frequency, and Temperature. Table 7 Options Option -1 -5 A2**** -FA Description 240 V Input 10 A Input External Auxiliary Power (120 Vac std.) Front Access **** Most XLP transducers come standard with internal auxiliary power (A4 option). If you require external auxiliary power, the A2 option designator should come before any other options in the complete model number. If you require additional options not shown here, please consult the factory. Combined Watt/Watthour or Var/Varhour and Combined Phase/Voltage Angle transducers are available in XLP format on special order. Please consult the factory for more information. Fax: 585-454-7805 90 SCI Transducer Cat 90-134(MTD) Description One 45° Phase Angle Unit One 60° Phase Angle Unit One 75° Phase Angle Unit One 180° Phase Angle Unit Two 45° Phase Angle Units Two 60° Phase Angle Units Two 75° Phase Angle Units Two 180° Phase Angle Units Table 6 Output Selection CURRENT OR VOLTAGE TRANSDUCERS IN ONE PLUG-IN MODULE Expanded-Scale Voltage Model No. XLPEX ONE OR TWO PHASE ANGLE TRANSDUCERS IN ONE PLUG-IN MODULE Instrumentation Position 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 Position 8 You must specify the size of enclosure and quantity of blank modules (if required). This information is not part of the model number, but must be provided to the factory when you place your order. Delete the "K" from the part numbers below if you do not want the factory to assemble your enclosure. Table 3 Phase Angle or Voltage Angle Base Model Numbers 91 90-91 1/9/02, 5:32 PM Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers WIRING DIAGRAMS WIRING DIAGRAMS Models C, C2, C3 Current Models CP7A2, C2P7A2, C3P7A2 Current with External Aux. Power Model CEP7A2 Current/Voltage with External Aux. Power Models CE, CE2, Current/Voltage (Consult factory for drawing of CE2P7A2) NUMBERS CORRESPOND TO CHANNEL NUMBERS ON P/C BOARD 1 1 2 INPUT CURRENT 1 INPUT CURRENT 1 AMPS 1 2 1 3 3 AMPS 2 4 INPUT CURRENT 2 2 AMPS 2 INPUT CURRENT 2 1 4 + OUTPUT 1 + OUTPUT 2 0-1 mAdc LOAD 0-10K OHMS 2 * 11 * OUTPUT LOAD RANGE OUTPUT 1-5 mA 4-20 mA LOAD RANGE 0-5K OHMS 0-1250 OHMS OUTPUT 2 * 10 11 + + * 6 OUTPUT 3 0-1 mAdc LOAD 0-10K OHMS 8 + 3 -007 + 9 OUTPUT 4 0-1 mAdc LOAD 0-10K OHMS 4 11 9 * * OUTPUT LOAD RANGE OUTPUT 1-5 mA 4-20 mA + OUTPUT 2 2 + LOAD RANGE 0-5K OHMS 0-1250 OHMS * 11 OUTPUT 5 0-1 mAdc LOAD 0-10K OHMS 12 14 OUTPUT 1 8 10 5 AUX. PWR. + 1 10 13 EXTERNAL AUX. POWER 7 OUTPUT 1 0-1 mAdc LOAD 0-10K OHMS 1 2 EXTERNAL AUX. POWER AUX. PWR. + 7 12 INPUT VOLTAGE 5 6 1 9 OUTPUT 3 12 INPUT VOLTAGE 2 5 8 10 3 VOLTS 2 4 VOLTS 5 OUTPUTS 9 4 XLP Plug-In OUTPUTS 8 INPUT CURRENT 1 3 + OUTPUTS OUTPUT 1 0-1 mAdc LOAD 0-10K OHMS INPUT VOLTAGE 4 5 7 1 VOLTS 4 AMPS 1 2 6 INPUT CURRENT 3 6 7 AMPS 3 INPUT CURRENT 3 AMPS 3 INPUT CURRENT 1 3 5 5 AMPS 1 OUTPUTS AMPS 1 12 -005 -008 Models E, E2, E3 Voltage Models EX, EX2, EX3 Expanded-Scale Voltage Models Z1, Z2 Frequency Models EP7A2, E2P7A2, E3P7A2 Voltage with External Aux. Power Models Z1P7A2, Z2P7A2 Frequency with External Aux. Power (Consult factory for drawing of Expanded-Scale Voltage with External Aux. Power) -013 Models CE3, C2E, C2E2, C2E3, C3E, C3E2, C3E3 Current/Voltage NUMBERS CORRESPOND TO CHANNEL NUMBERS ON PC BOARD 1 INPUT VOLTAGE 1 1 VOLTS 1 2 INPUT VOLTAGE 1 VOLTS 1 2 3 INPUT VOLTAGE 2 3 VOLTS 2 4 INPUT VOLTAGE 2 5 INPUT VOLTAGE 3 5 VOLTS 3 + * OUTPUTS * + OUTPUT 2 0-1 mAdc LOAD 0-10K OHMS 2 OUTPUT LOAD RANGE OUTPUT 1-5 mA 4-20 mA LOAD RANGE 0-5K OHMS 0-1250 OHMS OUTPUT 2 * 11 * 12 + 14 3 15 4 16 5 17 18 19 OUT 4 OUTPUT 5 0-1 mAdc OUT 5 OUTPUT 6 0-1 mAdc 2 6 OUTPUT 4 0-1 mAdc 12 8 20 + 9 21 10 22 + 11 OUT 6 12 INPUT CURRENT 1 INPUT VOLTAGE 4 VOLT 4 AMP 2 INPUT CURRENT 2 INPUT VOLTAGE 5 VOLT 5 AMP 3 INPUT CURRENT 3 INPUT VOLTAGE 6 VOLT 6 + OUT 1 OUT 2 OUT 3 AMETEK® Power Instruments 92 Rochester, New York 14605 15 18 + 7 19 OUT 5 255 North Union Street 3 6 OUTPUT 5 0-1 mAdc -013 14 17 OUTPUT 2 0-1 mAdc OUTPUT(S) 0-1 mA INTO 0-10K OHMS LOAD 14 2 5 OUT 4 OUTPUT 6 0-1 mAdc 13 16 OUTPUT 4 0-1 mAdc OUTPUT 3 0-1 mAdc 1 4 OUTPUT 1 0-1 mAdc + + 23 24 NUMBERS CORRESPOND TO CHANNEL NUMBERS ON PC BOARD AMP 1 AUX. PWR. -006 SCI Transducer Cat 90-134(MTD) 13 + 7 2 13 EXTERNAL AUX. POWER -006 VOLT 6 3 OUTPUT 3 OUTPUT 3 0-1 mAdc LOAD 0-10K OHMS + 10 11 3 INPUT VOLTAGE 6 1 9 10 + VOLT 5 8 OUTPUTS OUTPUT 1 0-1 mAdc LOAD 0-10K OHMS 9 + OUTPUT 1 8 INPUT VOLTAGE 5 VOLTS 3 7 1 VOLT 4 6 INPUT VOLTAGE 3 6 7 1 INPUT VOLTAGE 4 VOLTS 2 4 Models CE4, C2E4, Current/Voltage Model E4 Voltage 8 20 + 9 21 10 22 + 11 23 OUT 6 12 24 VOLT 1 INPUT VOLTAGE 1 AMP 2 INPUT CURRENT 2 AMP 3 INPUT CURRENT 3 XLPC2E4 ONLY + OUT 1 OUTPUT 1 0-1 mAdc + OUT 2 OUTPUT 2 0-1 mAdc + OUT 3 OUTPUT 3 0-1 mAdc OUTPUT(S) 0-1 mA INTO 0-10K OHMS LOAD -014 Phone: 1-800-274-5368 Fax: 585-454-7805 93 92-93 1/9/02, 5:32 PM Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers WIRING DIAGRAMS WIRING DIAGRAMS Models C, C2, C3 Current Models CP7A2, C2P7A2, C3P7A2 Current with External Aux. Power Models CE, CE2, Current/Voltage Model CEP7A2 Current/Voltage with External Aux. Power (Consult factory for drawing of CE2P7A2) NUMBERS CORRESPOND TO CHANNEL NUMBERS ON P/C BOARD 1 1 2 INPUT CURRENT 1 INPUT CURRENT 1 AMPS 1 2 1 3 3 AMPS 2 4 INPUT CURRENT 2 2 AMPS 2 INPUT CURRENT 2 1 4 AMPS 3 INPUT CURRENT 3 + OUTPUT 1 OUTPUT 1 0-1 mAdc LOAD 0-10K OHMS 9 + OUTPUT 2 0-1 mAdc LOAD 0-10K OHMS 2 11 VOLTS 5 * OUTPUT LOAD RANGE OUTPUT 1-5 mA 4-20 mA LOAD RANGE 0-5K OHMS 0-1250 OHMS 9 OUTPUT 2 * 10 11 + + * 6 OUTPUT 3 0-1 mAdc LOAD 0-10K OHMS 8 + 3 -007 + 9 OUTPUT 4 0-1 mAdc LOAD 0-10K OHMS 4 11 9 * * OUTPUT LOAD RANGE OUTPUT 1-5 mA 4-20 mA + OUTPUT 2 2 + LOAD RANGE 0-5K OHMS 0-1250 OHMS * 11 OUTPUT 5 0-1 mAdc LOAD 0-10K OHMS 12 14 OUTPUT 1 8 10 5 AUX. PWR. + 1 10 13 EXTERNAL AUX. POWER 7 OUTPUT 1 0-1 mAdc LOAD 0-10K OHMS 1 2 EXTERNAL AUX. POWER AUX. PWR. + 7 12 INPUT VOLTAGE 5 6 1 8 OUTPUT 3 12 INPUT VOLTAGE 2 5 + * 10 3 VOLTS 2 4 XLP Plug-In OUTPUTS 8 INPUT CURRENT 1 3 4 OUTPUTS 7 INPUT VOLTAGE 4 5 7 1 VOLTS 4 AMPS 1 2 6 INPUT CURRENT 3 6 OUTPUTS AMPS 3 INPUT CURRENT 1 3 5 5 AMPS 1 OUTPUTS AMPS 1 12 -005 -008 Models E, E2, E3 Voltage Models EX, EX2, EX3 Expanded-Scale Voltage Models Z1, Z2 Frequency Models EP7A2, E2P7A2, E3P7A2 Voltage with External Aux. Power Models Z1P7A2, Z2P7A2 Frequency with External Aux. Power (Consult factory for drawing of Expanded-Scale Voltage with External Aux. Power) -013 Models CE3, C2E, C2E2, C2E3, C3E, C3E2, C3E3 Current/Voltage NUMBERS CORRESPOND TO CHANNEL NUMBERS ON PC BOARD 1 INPUT VOLTAGE 1 1 VOLTS 1 2 INPUT VOLTAGE 1 VOLTS 1 2 3 INPUT VOLTAGE 2 3 VOLTS 2 4 INPUT VOLTAGE 2 5 INPUT VOLTAGE 3 5 VOLTS 3 + * OUTPUT 2 0-1 mAdc LOAD 0-10K OHMS 2 OUTPUT LOAD RANGE OUTPUT 1-5 mA 4-20 mA LOAD RANGE 0-5K OHMS 0-1250 OHMS 9 OUTPUT 2 * 10 11 * OUTPUT 3 0-1 mAdc LOAD 0-10K OHMS 12 VOLT 6 13 EXTERNAL AUX. POWER -006 OUTPUT 5 0-1 mAdc OUT 5 255 North Union Street Rochester, New York 14605 4 16 5 17 8 20 + 9 21 10 22 + 11 OUT 6 12 INPUT CURRENT 1 INPUT VOLTAGE 4 VOLT 4 AMP 2 INPUT CURRENT 2 INPUT VOLTAGE 5 VOLT 5 AMP 3 INPUT CURRENT 3 INPUT VOLTAGE 6 VOLT 6 + OUT 1 OUT 2 + 23 24 OUT 3 Phone: 1-800-274-5368 -013 14 3 15 17 6 18 + 7 19 OUTPUT 2 0-1 mAdc OUTPUT 5 0-1 mAdc OUT 5 OUTPUT(S) 0-1 mA INTO 0-10K OHMS LOAD 2 5 OUT 4 OUTPUT 6 0-1 mAdc 13 16 OUTPUT 4 0-1 mAdc OUTPUT 3 0-1 mAdc 1 4 OUTPUT 1 0-1 mAdc + 14 8 20 + 9 21 10 22 + 11 23 OUT 6 12 24 VOLT 1 INPUT VOLTAGE 1 AMP 2 INPUT CURRENT 2 AMP 3 INPUT CURRENT 3 XLPC2E4 ONLY + OUT 1 OUTPUT 1 0-1 mAdc + OUT 2 OUTPUT 2 0-1 mAdc + OUT 3 OUTPUT 3 0-1 mAdc OUTPUT(S) 0-1 mA INTO 0-10K OHMS LOAD -014 Fax: 585-454-7805 92 SCI Transducer Cat 90-134(MTD) 15 NUMBERS CORRESPOND TO CHANNEL NUMBERS ON PC BOARD AMP 1 AUX. PWR. -006 AMETEK® Power Instruments 3 19 OUT 4 OUTPUT 6 0-1 mAdc 14 18 OUTPUT 4 0-1 mAdc 12 2 6 2 + 13 + 7 3 OUTPUT 3 + + 10 11 3 INPUT VOLTAGE 6 1 OUTPUTS OUTPUTS * + VOLT 5 8 OUTPUT 1 0-1 mAdc LOAD 0-10K OHMS 9 + OUTPUT 1 8 INPUT VOLTAGE 5 VOLTS 3 7 1 VOLT 4 6 INPUT VOLTAGE 3 6 7 1 INPUT VOLTAGE 4 VOLTS 2 4 Models CE4, C2E4, Current/Voltage Model E4 Voltage 93 92-93 1/9/02, 5:32 PM Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers WIRING DIAGRAMS WIRING DIAGRAMS 1-Element Watt, Var, Watt/Var with External Aux. Power 1-Element Watt, Var, Watt/Var LINE A A B A 1 IA AMPS C LINE B A C 1 1 1 IA LINE B LINE B 2-Element Watt, Var, Watt/Var with External Aux. Power 2-Element Watt, Var, Watt/Var IA AMPS 2 2 2 3 3 3 IA AMPS AMPS 2 3 IC AMPS IC 4 AMPS 4 4 4 5 5 5 5 EA VOLTS E AB VOLTS 6 6 6 7 7 7 8 E CB EXTERNAL AUX. POWER VOLTS LOAD 8 8 9 LOAD VAR OUTPUT WATT * OUTPUT LOAD RANGE * WATT OUTPUT 12 * OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 10 11 VAR + VAR OUTPUT * OUTPUT LOAD RANGE * + WATT WATT OUTPUT * OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA OUTPUTS 11 + VAR OUTPUTS OUTPUTS + 9 9 LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 11 + VAR VAR OUTPUT * + WATT WATT OUTPUT 12 12 -001 10 * AUX. PWR. 10 * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 11 * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS VAR OUTPUT * VAR 12 13 * + WATT WATT OUTPUT 14 -003 -004 + -001 11/2-Element Watt, Var, Watt/Var A LINE B 11/2-Element Watt, Var, Watt/Var with External Aux. Power A C 1 LINE B C 21/2-Element Watt, Var, Watt/Var A LINE B C LINE B C N IA AMPS AMPS 2 A 1 IA AMPS 21/2-Element Watt, Var, Watt/Var with External Aux. Power N 1 IA AMPS 2 3 3 3 AMPS 4 5 5 AMPS 4 AMPS 4 IB AMPS IC E AC VOLTS VOLTS 6 6 7 7 E AN VOLTS LOAD EXTERNAL AUX. POWER 8 9 10 + 11 + VAR OUTPUT VAR WATT 12 * WATT OUTPUT * * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS OUTPUTS OUTPUTS 9 10 11 + VAR VAR OUTPUT + WATT 12 -002 * WATT OUTPUT * * VOLTS 10 OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS -005 VAR OUTPUT * VAR 12 13 WATT OUTPUT * + LOAD + + WATT OUTPUT WATT 3 15 * OUTPUT LOAD RANGE 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS EXTERNAL AUX. POWER ECN LOAD 11 14 EAN E CN VOLTS 9 VOLTS 8 2 IC 7 AUX. PWR. LOAD 8 AMPS OUTPUTS E AC IC 6 13 IB 5 AMPS 1 IA 2 IC XLP Plug-In 10 EXTERNAL AUX. POWER LOAD 9 E CB VOLTS 7 LOAD AUX. PWR. 8 E AB 6 VOLTS OUTPUTS EA VOLTS + * VAR OUTPUT * -011 14 -002 AMETEK® Power Instruments 94 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 95 94-95 1/9/02, 5:32 PM Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers WIRING DIAGRAMS WIRING DIAGRAMS 1-Element Watt, Var, Watt/Var with External Aux. Power 1-Element Watt, Var, Watt/Var LINE A A B A 1 IA AMPS C LINE B A C 1 1 1 IA LINE B LINE B 2-Element Watt, Var, Watt/Var with External Aux. Power 2-Element Watt, Var, Watt/Var IA AMPS 2 2 2 3 3 3 IA AMPS AMPS 2 3 IC AMPS IC 4 AMPS 4 4 4 5 5 5 5 EA VOLTS E AB VOLTS 6 6 6 7 7 7 8 E CB EXTERNAL AUX. POWER VOLTS LOAD 8 8 9 LOAD VAR OUTPUT WATT * OUTPUT LOAD RANGE * WATT OUTPUT 12 * OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 10 11 VAR + VAR OUTPUT * OUTPUT LOAD RANGE * + WATT WATT OUTPUT * OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA OUTPUTS 11 + VAR OUTPUTS OUTPUTS + 9 9 LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 11 + VAR VAR OUTPUT * + WATT 12 12 -001 10 WATT OUTPUT * AUX. PWR. 10 * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 11 * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS VAR OUTPUT * VAR 12 13 * + WATT WATT OUTPUT 14 -003 -004 + -001 11/2-Element Watt, Var, Watt/Var A LINE B 11/2-Element Watt, Var, Watt/Var with External Aux. Power A C 1 LINE B C 21/2-Element Watt, Var, Watt/Var A LINE B C LINE B C IA AMPS AMPS 2 A N 1 IA AMPS 21/2-Element Watt, Var, Watt/Var with External Aux. Power N 1 IA AMPS 2 3 3 3 AMPS 4 5 5 AMPS 4 AMPS 4 IB AMPS IC E AC VOLTS VOLTS 6 6 7 7 E AN VOLTS LOAD EXTERNAL AUX. POWER 8 9 10 + 11 + VAR OUTPUT VAR WATT * WATT OUTPUT * * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 12 OUTPUTS OUTPUTS 9 10 11 + VAR VAR OUTPUT * + WATT WATT OUTPUT * * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 12 -002 VOLTS 10 * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA -005 LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS VAR OUTPUT * VAR 12 13 WATT OUTPUT * + LOAD + + WATT OUTPUT WATT 3 15 * OUTPUT LOAD RANGE 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS EXTERNAL AUX. POWER ECN LOAD 11 14 EAN E CN VOLTS 9 VOLTS 8 2 IC 7 AUX. PWR. LOAD 8 AMPS OUTPUTS E AC IC 6 13 IB 5 AMPS 1 IA 2 IC XLP Plug-In 10 EXTERNAL AUX. POWER LOAD 9 E CB VOLTS 7 LOAD AUX. PWR. 8 E AB 6 VOLTS OUTPUTS EA VOLTS + * VAR OUTPUT * -011 14 -002 AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 94 SCI Transducer Cat 90-134(MTD) 95 94-95 1/9/02, 5:32 PM Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers WIRING DIAGRAMS WIRING DIAGRAMS 3-Element Watt, Var, Watt/Var with External Aux. Power LINE C A N N 1 IA AMPS AMPS 2 IB AMPS 4 13 2 14 3 15 E1A * OUTPUT LOAD RANGE 16 5 17 OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA 5 IC AMPS AMPS 6 7 EA 8 EB 9 EC VOLTS VOLTS VOLTS VOLTS VOLTS N 10 OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA 13 LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS WATT OUTPUT * 18 EA 7 19 EB 8 20 9 21 VOLTS * OUTPUTS OUTPUT LOAD RANGE 12 + + + WATT WATT OUTPUT 4 LOAD LINE VOLTS 10 22 11 23 AMPS 8 9 + 24 * LA VOLTS * LB 5 LA E 2A VOLTS + CH. 2 CHANNEL 2 OUTPUT 12 * LB 7 LA E 2B VOLTS LOAD RANGE 0-10K OHMS 0-5K OHMS 0-1250 OHMS LB 1 C H A N N E L 2 + CH. 1 CHANNEL 1 OUTPUT * 10 + 11 CH. 2 * C H A N N E L SYSTEM B 8 12 -012 -012 SYSTEM A 6 OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-3-5 mA 4-12-20 mA SYSTEM B 4 9 10 * 3 + CHANNEL 1 OUTPUT SYSTEM A LB E1B 2 LOAD CH. 1 11 VOLTS 2 C H A N N E L 5 E 2A LA E1A 1 7 EXTERNAL AUX. POWER 12 14 AMPS I 2A VAR OUTPUT LOAD 3 I 1A 1 CHANNEL 2 OUTPUT * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-3-5 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-1250 OHMS * -011 -003 Three 1-Element Watt/Vars in One Module with or without External Aux. Power A LINE B C Models T1, T2 Temperature N 1 1 AMPS AMPS VOLTS AMPS VOLTS 2 14 3 15 4 16 5 17 6 18 7 19 8 20 EC 22 11 23 12 24 4 VAR B OUTPUT WATT B OUTPUT O U T P U T S 6 RTD2 RTD2 7 8 COM 9 COM VAR C OUTPUT + + WC EXTERNAL AUX. POWER (opt.) RTD1 3 5 + + VC 10 2 RTD1 COM WB 21 WATT A OUTPUT O U T P U T S COM VB 9 VAR A OUTPUT + + WA IC EA COM VA IB N VOLTS 13 IA EB LOAD XLP Plug-In * VAR OUTPUT LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 6 6 N VAR LOAD IC EC 11 VOLTS 2 IB 4 C H A N N E L LINE 1 1 IA 3 AMPS Models A1, A2 Voltage Angle Models F1, F2 Phase Angle OUTPUTS B A LINE B C OUTPUTS 3-Element Watt, Var, Watt/Var WATT C OUTPUT * O U T P U T S OUTPUT LOAD RANGE OUTPUT 0-1 mA 1-5 mA 4-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-1250 OHMS CHANNEL 1 OUTPUT * 10 11 CHANNEL 2 OUTPUT * 12 COM -015 EXTERNAL AUX. POWER OUTPUT(S) 0 to + 1 mA INTO 0-5K OHMS LOAD + CH. 1 OUT + CH. 2 OUT 13 AUX. PWR. 14 -004 AMETEK® Power Instruments 96 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 97 96-97 1/9/02, 5:32 PM Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers Wiring Diagrams Exceltronic XLP Modular Plug-In Transducers WIRING DIAGRAMS WIRING DIAGRAMS 3-Element Watt, Var, Watt/Var with External Aux. Power LINE C A N N 1 IA AMPS AMPS 2 IB AMPS 4 13 2 14 3 15 E1A * OUTPUT LOAD RANGE 16 5 17 OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA 5 IC AMPS AMPS 6 7 EA 8 EB 9 EC VOLTS VOLTS VOLTS VOLTS VOLTS N 10 OUTPUT 0 to + 1 mA 1-5 mA 1-3-5 mA 4-20 mA 4-12-20 mA 13 LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS WATT OUTPUT * 18 EA 7 19 EB 8 20 9 21 VOLTS * OUTPUTS OUTPUT LOAD RANGE 12 + + + WATT WATT OUTPUT 4 LOAD LINE VOLTS 10 22 11 23 AMPS 8 9 + 24 * LA VOLTS * LB 5 LA E 2A VOLTS + CH. 2 CHANNEL 2 OUTPUT 12 * LB 7 LA E 2B VOLTS LOAD RANGE 0-10K OHMS 0-5K OHMS 0-1250 OHMS LB CH. 1 A LINE B C CHANNEL 1 OUTPUT * + 11 CH. 2 12 -011 -003 Three 1-Element Watt/Vars in One Module with or without External Aux. Power 1 C H A N N E L 2 + 10 * C H A N N E L SYSTEM B 8 -012 -012 SYSTEM A 6 OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-3-5 mA 4-12-20 mA SYSTEM B 4 9 10 * 3 + CHANNEL 1 OUTPUT SYSTEM A LB E1B 2 LOAD CH. 1 11 VOLTS 2 C H A N N E L 5 E 2A LA E1A 1 7 EXTERNAL AUX. POWER 12 14 AMPS I 2A VAR OUTPUT LOAD 3 I 1A 1 CHANNEL 2 OUTPUT * * OUTPUT LOAD RANGE OUTPUT 0 to + 1 mA 1-3-5 mA 4-12-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-1250 OHMS XLP Plug-In * VAR OUTPUT LOAD RANGE 0-10K OHMS 0-5K OHMS 0-5K OHMS 0-1250 OHMS 0-1250 OHMS 6 6 N VAR LOAD IC EC 11 VOLTS 2 IB 4 C H A N N E L LINE 1 1 IA 3 AMPS Models A1, A2 Voltage Angle Models F1, F2 Phase Angle OUTPUTS B A LINE B C OUTPUTS 3-Element Watt, Var, Watt/Var Models T1, T2 Temperature N 1 1 AMPS AMPS VOLTS AMPS VOLTS 2 14 3 15 4 16 5 17 6 18 7 19 8 20 IB EC N 22 11 23 LOAD 12 24 4 VAR B OUTPUT WATT B OUTPUT O U T P U T S 6 RTD2 RTD2 7 8 COM 9 COM VAR C OUTPUT + + WC EXTERNAL AUX. POWER (opt.) RTD1 3 5 + + VC 10 2 RTD1 COM WB 21 WATT A OUTPUT O U T P U T S COM VB 9 VAR A OUTPUT + + WA IC EA COM VA IA EB VOLTS 13 WATT C OUTPUT * O U T P U T S OUTPUT LOAD RANGE OUTPUT 0-1 mA 1-5 mA 4-20 mA LOAD RANGE 0-10K OHMS 0-5K OHMS 0-1250 OHMS CHANNEL 1 OUTPUT * 10 11 CHANNEL 2 OUTPUT * 12 COM -015 EXTERNAL AUX. POWER OUTPUT(S) 0 to + 1 mA INTO 0-5K OHMS LOAD + CH. 1 OUT + CH. 2 OUT 13 AUX. PWR. 14 -004 AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 96 SCI Transducer Cat 90-134(MTD) 97 96-97 1/9/02, 5:32 PM Test Equipment Exceltronic XLP Modular Plug-In Transducers AVAILABLE TEST EQUIPMENT Scientific Columbus offers three testing devices for use with XLP transducers: Test Fixture (Model XLP 6329B) This device is used for bench calibrating and troubleshooting XLP transducer modules. The test fixture contains all of the various types of current transformers necessary to cover all of the different transducer configurations. Special switching selects the transducer configuration for the unit under test. All calibration is performed using the single-phase method. This fixture is intended as a method of making electrical connections to the modules; it does not contain the necessary power source and reference standards. The Model 6444 Calibrator (see pages 120–121) is available for that purpose. Output Loop Tester (Model XLP 6304) This test module uses internal batteries to generate a very accurate 0.1 or 1 mAdc signal for testing equipment connected to the output loops of any of the XLP modules. A self-contained voltmeter measures the voltage across the loop under test to check for loop resistance or intermittent open circuits. SCIENTIFIC Exceltronic II XLG AC Transducers COLUMBUS The Exceltronic II XLG is a lower-priced line of transducers that meets all common energymeasurement needs. Its 0.2% accuracy level permits measurement or monitoring of any circuit at minimal cost. Smaller can size with 4–20 mAdc output makes these transducers ideal for industrial applications and generating stations. The XLG is available in current, voltage, watt, var, and combined watt/var units with 5 A or 120 V input levels on all units. The current and voltage units also have options for 10 A and 240 V inputs. Frequency levels of 50 or 60 Hz are available on all units. The 60 Hz XLG line is UL Recognized, and both 50 and 60 Hz models meet the ANSI/IEEE C37.90.1-1989 surgewithstand test. Input Signal Tester (Model XLP 6303) This plug-in test module measures all 5 A or 150 V inputs to the XLP back-panel assemblies. It does not measure RTD inputs to temperature transducers. Its self-contained meter (0-5 A and 0-150 V ranges) allows 2% full-scale accuracy measurements. A front-panel jack allows up to 0.25% accuracy with an external 0-1 mAdc meter, such as a battery-powered DVM (digital voltmeter). An overload indicator is mounted on the front panel of the tester to indicate false readings due to an input overload. ◆ Accuracy to 0.2% of reading ◆ Process control ◆ 0 to ±1 mAdc ◆ UL Recognized ◆ Generating stations ◆ 4–20 mAdc ◆ Excellent long-term stability ◆ SCADA ◆ 4–12–20 mAdc Consult the factory for complete information on these test devices. ◆ Isolated outputs on combined watt/var units ◆ Substation monitoring ◆ Unidirectional & bidirectional outputs on combination watt/var units Features Applications JEM MULTIFUNCTION TRANSDUCER As an alternative to the XLP plug-in transducers, Scientific Columbus offers a multifunction transducer packaged in a JEM®1-style case (dimensions are approximately 6.3" W x 7.6" D x 8.9" H or 161 mm x 192 mm x 227 mm). Functions available are watt, var, volt-amp, amp, amp2, volt, volt2, expanded-scale volt, plus integrated quantities for each of the above functions (watthours, etc.). Up to three functions can be packaged in one case (the third function is limited to one of the volt functions). Consult the factory for specifications and ordering information. Exceltronic II XLG Transducers Provide Unique Process-Control Measurements The Exceltronic II XLG Transducer line provides utilities with accuracy and measurement flexibility, and brings precision, utility-grade power measurement and control to the process-control industry. Through the development of patented measurement technology, outputs of 4–20 mAdc and zero-center 4–12–20 mAdc are combined with Exceltronic design in smaller, versatile enclosures. Scientific Columbus XLG Transducers provide precise measurement of voltage, current, watts (real power), and vars (reactive power), and can be utilized in many ways as inputs to your process-control system. Applications include early detection of machinery failure and electrical balance of the power system. AMETEK® Power Instruments 98 SCI Transducer Cat 90-134(MTD) XLG ◆ 2500 VRMS isolation ® Outputs 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 99 98-99 1/9/02, 5:33 PM SCIENTIFIC Exceltronic II XLG AC Transducers COLUMBUS Test Equipment Exceltronic XLP Modular Plug-In Transducers AVAILABLE TEST EQUIPMENT Scientific Columbus offers three testing devices for use with XLP transducers: The Exceltronic II XLG is a lower-priced line of transducers that meets all common energymeasurement needs. Its 0.2% accuracy level permits measurement or monitoring of any circuit at minimal cost. Smaller can size with 4–20 mAdc output makes these transducers ideal for industrial applications and generating stations. Test Fixture (Model XLP 6329B) This device is used for bench calibrating and troubleshooting XLP transducer modules. The test fixture contains all of the various types of current transformers necessary to cover all of the different transducer configurations. Special switching selects the transducer configuration for the unit under test. All calibration is performed using the single-phase method. This fixture is intended as a method of making electrical connections to the modules; it does not contain the necessary power source and reference standards. The Model 6444 Calibrator (see pages 120–121) is available for that purpose. Output Loop Tester (Model XLP 6304) This test module uses internal batteries to generate a very accurate 0.1 or 1 mAdc signal for testing equipment connected to the output loops of any of the XLP modules. A self-contained voltmeter measures the voltage across the loop under test to check for loop resistance or intermittent open circuits. The XLG is available in current, voltage, watt, var, and combined watt/var units with 5 A or 120 V input levels on all units. The current and voltage units also have options for 10 A and 240 V inputs. Frequency levels of 50 or 60 Hz are available on all units. The 60 Hz XLG line is UL Recognized, and both 50 and 60 Hz models meet the ANSI/IEEE C37.90.1-1989 surgewithstand test. Input Signal Tester (Model XLP 6303) This plug-in test module measures all 5 A or 150 V inputs to the XLP back-panel assemblies. It does not measure RTD inputs to temperature transducers. Its self-contained meter (0-5 A and 0-150 V ranges) allows 2% full-scale accuracy measurements. A front-panel jack allows up to 0.25% accuracy with an external 0-1 mAdc meter, such as a battery-powered DVM (digital voltmeter). An overload indicator is mounted on the front panel of the tester to indicate false readings due to an input overload. ◆ Accuracy to 0.2% of reading ◆ Process control ◆ 0 to ±1 mAdc ◆ UL Recognized ◆ Generating stations ◆ 4–20 mAdc ◆ Excellent long-term stability ◆ SCADA ◆ 4–12–20 mAdc Consult the factory for complete information on these test devices. ◆ Isolated outputs on combined watt/var units ◆ Substation monitoring ◆ Unidirectional & bidirectional outputs on combination watt/var units Features JEM MULTIFUNCTION TRANSDUCER As an alternative to the XLP plug-in transducers, Scientific Columbus offers a multifunction transducer packaged in a JEM®1-style case (dimensions are approximately 6.3" W x 7.6" D x 8.9" H or 161 mm x 192 mm x 227 mm). Functions available are watt, var, volt-amp, amp, amp2, volt, volt2, expanded-scale volt, plus integrated quantities for each of the above functions (watthours, etc.). Up to three functions can be packaged in one case (the third function is limited to one of the volt functions). Consult the factory for specifications and ordering information. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Exceltronic II XLG Transducers Provide Unique Process-Control Measurements The Exceltronic II XLG Transducer line provides utilities with accuracy and measurement flexibility, and brings precision, utility-grade power measurement and control to the process-control industry. Through the development of patented measurement technology, outputs of 4–20 mAdc and zero-center 4–12–20 mAdc are combined with Exceltronic design in smaller, versatile enclosures. Scientific Columbus XLG Transducers provide precise measurement of voltage, current, watts (real power), and vars (reactive power), and can be utilized in many ways as inputs to your process-control system. Applications include early detection of machinery failure and electrical balance of the power system. Fax: 585-454-7805 98 SCI Transducer Cat 90-134(MTD) Outputs XLG ◆ 2500 VRMS isolation ® Applications 99 98-99 1/9/02, 5:33 PM Specifications Exceltronic II XLG AC Average-Sensing Current or Voltage Transducers Ordering Procedure & Case Dimensions Exceltronic II XLG AC Average-Sensing Current or Voltage Transducers ORDERING PROCEDURE Specifications Option A 5A 0–5 A 0–7.5 A 15 A 250 A 0.25 VA (maximum) at 5 A Option D 10 A 0–10 A 0–15 A 20 A 250 A 0.35 VA (maximum) at 10 A Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden/Element Rated Output (RO) = 5 A or 150 V/Element N/A Option 3 240 V 0–300 V 0–300 V 300 V 2.2 VA (maximum) at 120 V None Required 85–150 Vac 50–500 Hz 2.5 VA (maximum) at 120 V None Required 85–150 Vac 50–500 Hz 2.5 VA (maximum) at 120 V 1 mAdc for Standard Calibration 20 mAdc for Standard Calibration 1 mAdc for Standard Calibration 20 mAdc for Standard Calibration N/A Operating Temperature Range Compliance Voltage Load ± 0.0075% / ° C (typical) - 0.015% / ° C (typical) V 10 1 - 1 EXAMPLE: XLGV10S1-1 Voltage Transducer, 1 element, self-powered (internal auxiliary power), 0-1 mAdc output, 120 V input. Elements 10 = 1 Element (single) 30 = 3 Element (triple) Auxiliary Power S = Self-Powered (internal auxiliary power)—0-1 mAdc units only E = External Auxiliary Power (120 Vac std.)—4-20 mAdc units only 50-60 Hz is standard on all XLG Current and Voltage Transducers. Output 1 = 0-1 mAdc 4 = 4-20 mAdc (unidirectional) -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc 15 Vdc 10 Vdc 15 Vdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc < 400 ms to 99% < 500 ms to 99% Current Units Voltage Units A=5A D = 10 A 1 = 120 V 3 = 240 V CASE DIMENSIONS (Styles III & II Cases) < 0.5% RO Response Time Gain Zero < 400 ms to 99% < 500 ms to 99% ±10% of Reading (minimum) ± 20% of Reading (minimum) ±10% of Reading (minimum) ± 20% of Reading (minimum) None Required ±5% of Zero Point (minimum) None Required ±5% of Zero Point (minimum) Frequency Range 48–62 Hz Stability (per year) ±0.25% RO, Noncumulative Operating Humidity Single Current or Voltage (Style III Case) SCREW HEAD PROTRUDES .46" (11.68 mm) 0–95% Noncondensing Complete (Input/Output/Case) Isolation Dielectric Withstand Complete (Input/Output/Power/Case) Complete (Input/Output/Case) Complete (Input/Output/Power/Case) .09" (2.29 mm) (TYP.) FROM CASE 2 SCREWS Single Triple 1 lb., 1 oz. (0.5 kg) 2 lbs., 9 oz. (1.2 kg) Approximate Dimensions (excluding mounting plate) Single 3.3" W x 2.1" D x 4.3" H (84 mm x 53 mm x 109 mm) Style III Case, see page 122 .75" (19.05 mm) .094" RAD. (2.39 mm) 3.53" (89.66 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 3.07" (77.98 mm) 3.50" (88.90 mm) ANSI/IEEE C37.90.1-1989 Maximum Net Weight .25" (6.35 mm) .23" (5.84 mm) .25" (6.35 mm) 2500 VRMS at 60 Hz Surge Withstand .187" DIA. (4.75 mm) 2 MOUNTING HOLES .07" (1.78 mm) 4.00" (101.60 mm) Triple Current or Voltage (Style II Case) 1.14" (28.96 mm) Triple 4.4" W x 3.9" D x 4.9" H (112 mm x 99 mm x 124 mm) Style II Case, see page 122 SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) .75" (19.05 mm) 2.00" (50.80 mm) .094" RAD. (2.39 mm) Specifications subject to change without notice. .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.75" (120.65 mm) 5.25" (133.35 mm) AMETEK® Power Instruments 100 4.15" (105.41 mm) .23" (5.84 mm) 3.77" (95.76 mm) 4.40" (111.76 mm) SCI Transducer Cat 90-134(MTD) S XLG -20° C to +60° C Output Ripple Peak XLG Input ± 0.2% RO Temperature Effect on Accuracy XLG Model Number: Transducer Type V = Voltage I = Current Option 1 120 V 0–150 V 0–150 V 180 V 2.2 VA (maximum) at 120 V Accuracy Standard Calibration Adjustments 4–20 mAdc Volts (Voltage Transducer) 0–1 mAdc Volts (Voltage Transducer) 1.50" (38.10 mm) Voltage Input Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element 4–20 mAdc Amps (Current Transducer) 2.05" (52.07 mm) Current Input 0–1 mAdc Amps (Current Transducer) 255 North Union Street .07" (1.78 mm) Terminal strips shown for illustration purposes only. For exact terminalstrip configuration on specific units, see connection diagrams on page 98. Drawings not to scale. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 101 100-101 1/9/02, 5:33 PM Specifications Exceltronic II XLG AC Average-Sensing Current or Voltage Transducers Ordering Procedure & Case Dimensions Exceltronic II XLG AC Average-Sensing Current or Voltage Transducers ORDERING PROCEDURE Specifications Option A 5A 0–5 A 0–7.5 A 15 A 250 A 0.25 VA (maximum) at 5 A Option D 10 A 0–10 A 0–15 A 20 A 250 A 0.35 VA (maximum) at 10 A Nominal Calibrating Range Range with Linearity Overload Continuous Burden/Element External Input Range Auxiliary Frequency Range Power Burden/Element Rated Output (RO) = 5 A or 150 V/Element N/A Option 3 240 V 0–300 V 0–300 V 300 V 2.2 VA (maximum) at 120 V None Required 85–150 Vac 50–500 Hz 2.5 VA (maximum) at 120 V None Required 85–150 Vac 50–500 Hz 2.5 VA (maximum) at 120 V 1 mAdc for Standard Calibration 20 mAdc for Standard Calibration 1 mAdc for Standard Calibration 20 mAdc for Standard Calibration N/A Operating Temperature Range Compliance Voltage Load ± 0.0075% / ° C (typical) - 0.015% / ° C (typical) V S 1 - 1 EXAMPLE: XLGV10S1-1 Voltage Transducer, 1 element, self-powered (internal auxiliary power), 0-1 mAdc output, 120 V input. Elements 10 = 1 Element (single) 30 = 3 Element (triple) Auxiliary Power S = Self-Powered (internal auxiliary power)—0-1 mAdc units only E = External Auxiliary Power (120 Vac std.)—4-20 mAdc units only 50-60 Hz is standard on all XLG Current and Voltage Transducers. Output 1 = 0-1 mAdc 4 = 4-20 mAdc (unidirectional) -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc 15 Vdc 10 Vdc 15 Vdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc < 400 ms to 99% < 500 ms to 99% Current Units Voltage Units A=5A D = 10 A 1 = 120 V 3 = 240 V CASE DIMENSIONS (Styles III & II Cases) < 0.5% RO Response Time Gain Zero < 400 ms to 99% < 500 ms to 99% ±10% of Reading (minimum) ± 20% of Reading (minimum) ±10% of Reading (minimum) ± 20% of Reading (minimum) None Required ±5% of Zero Point (minimum) None Required ±5% of Zero Point (minimum) Frequency Range 48–62 Hz Stability (per year) ±0.25% RO, Noncumulative Operating Humidity Single Current or Voltage (Style III Case) SCREW HEAD PROTRUDES .46" (11.68 mm) 0–95% Noncondensing Complete (Input/Output/Case) Isolation Dielectric Withstand Complete (Input/Output/Power/Case) Complete (Input/Output/Case) Complete (Input/Output/Power/Case) .09" (2.29 mm) (TYP.) FROM CASE 2 SCREWS Single Triple 1 lb., 1 oz. (0.5 kg) 2 lbs., 9 oz. (1.2 kg) Approximate Dimensions (excluding mounting plate) Single 3.3" W x 2.1" D x 4.3" H (84 mm x 53 mm x 109 mm) Style III Case, see page 122 1.14" (28.96 mm) 3.07" (77.98 mm) 3.50" (88.90 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES .07" (1.78 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) .75" (19.05 mm) 2.00" (50.80 mm) .094" RAD. (2.39 mm) Specifications subject to change without notice. .23" (5.84 mm) 3.77" (95.76 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.75" (120.65 mm) 5.25" (133.35 mm) Phone: 1-800-274-5368 4.15" (105.41 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) 4.40" (111.76 mm) Rochester, New York 14605 3.53" (89.66 mm) Triple Current or Voltage (Style II Case) 4.4" W x 3.9" D x 4.9" H (112 mm x 99 mm x 124 mm) Style II Case, see page 122 255 North Union Street .75" (19.05 mm) 4.00" (101.60 mm) Triple AMETEK® Power Instruments .094" RAD. (2.39 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS ANSI/IEEE C37.90.1-1989 Maximum Net Weight .25" (6.35 mm) .23" (5.84 mm) .25" (6.35 mm) 2500 VRMS at 60 Hz Surge Withstand .07" (1.78 mm) Terminal strips shown for illustration purposes only. For exact terminalstrip configuration on specific units, see connection diagrams on page 98. Drawings not to scale. Fax: 585-454-7805 100 SCI Transducer Cat 90-134(MTD) 10 XLG -20° C to +60° C Output Ripple Peak XLG Input ± 0.2% RO Temperature Effect on Accuracy XLG Model Number: Transducer Type V = Voltage I = Current Option 1 120 V 0–150 V 0–150 V 180 V 2.2 VA (maximum) at 120 V Accuracy Standard Calibration Adjustments 4–20 mAdc Volts (Voltage Transducer) 0–1 mAdc Volts (Voltage Transducer) 1.50" (38.10 mm) Voltage Input Nominal Calibrating Range Range with Linearity Overload Continuous Overload 1 Second/Hour Burden/Element 4–20 mAdc Amps (Current Transducer) 2.05" (52.07 mm) Current Input 0–1 mAdc Amps (Current Transducer) 101 100-101 1/9/02, 5:33 PM Wiring Diagrams Exceltronic II XLG AC Average-Sensing Current or Voltage Transducers Specifications Exceltronic II XLG AC Watt or Var Transducers WIRING DIAGRAMS FOR 0-1 mAdc AND 4-20 mAdc UNITS (Styles III & II Cases) Specifications 0-1 mAdc Units Triple Current or Voltage (Style II Case) Single Current or Voltage (Style III Case) AO CO - + - + - + 1 2 3 2 4 3 5 Voltage Input Nominal Range* Overload Continuous Burden/Element 6 8 11 10 9 CO AC INPUT AC INPUT 85–150 Vac 50–500 Hz 4 VA (maximum) at 120 V 85–150 Vac 50–500 Hz 4.5 VA (maximum) at 120 V ± (0.1% Reading + 0.05% RO) at 0–200% RO ± 0.2% of Output Range ± (0.1% Reading + 0.1% RO) at 0–200% RO ± 0.2% of Output Range Temperature Effect on Accuracy ±0.005% / ° C (typical) ±0.0075% / ° C (typical) ±0.0075% / ° C (typical) ±0.008% / ° C (typical) Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc 15 Vdc 10 Vdc 15 Vdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc < 400 ms to 99% < 500 ms to 99% Compliance Voltage < 0.5% RO Output Ripple Peak Response Time Power Factor 4-20 mAdc Units Single Current or Voltage (Style III Case) Gain Zero Frequency Range ±2% of Reading (minimum) ± 20% of Reading (minimum) None Required ±5% of Zero Point (minimum) ±2% of Reading (minimum) ± 20% of Reading (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz 60 Hz ±0.25% RO, Noncumulative Stability (per year) Triple Current or Voltage (Style II Case) 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Power/Case) 2500 VRMS at 60 Hz Dielectric Withstand AO EXTERNAL AUX. POWER AC INPUT BO Surge Withstand CO - + - + - + Approximate Dimensions (excluding mounting plate) DC OUTPUT - Overrange with Linearity + 1 2 3 1 4 5 2 3 4 5 6 6A EXTERNAL AUX. POWER 8 9 10 11 2 lbs., 11 oz. (1.2 kg) 4.4" W x 3.9" D x 4.9" H (112 mm x 99 mm x 124 mm) Style II Case, see page 122 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. 6 7 ANSI/IEEE C37.90.1-1989 Maximum Net Weight DC DC DC OUTPUT OUTPUT OUTPUT < 500 ms to 99% ± 0.2% RO (maximum) PF Effect on Accuracy Standard Calibration Adjustments < 400 ms to 99% Any XLG BO AC INPUT 120 V 0–150 V 180 V 0.035 VA (maximum) at 120 V 20 mAdc for Standard Calibration Load AO 5A 0–10 A 15 A 250 A 0.3 VA (maximum) at 5 A ±1 mAdc for Standard Calibration Accuracy 12 4–20 mAdc Vars (Var Transducer) 20 mAdc for Standard Calibration 4 7 0 to ±1 mAdc Vars (Var Transducer) 4–20 mAdc Watts (Watt Transducer) ±1 mAdc for Standard Calibration Rated Output (RO) = 500 Watts or Vars/Element + 1 Nominal Range* Overload Continuous Overload 1 Second/Hour Burden/Element External Input Range Auxiliary Frequency Range Power Burden DC DC DC OUTPUT OUTPUT OUTPUT AC INPUT DC OUTPUT - BO Current Input 0 to ±1 mAdc Watts (Watt Transducer) *Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with 4–20 mAdc output. Specifications subject to change without notice. 12 12A AO BO CO AC INPUT AC INPUT AC INPUT Adjust AMETEK® Power Instruments 102 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 103 102-103 1/9/02, 5:33 PM Wiring Diagrams Exceltronic II XLG AC Average-Sensing Current or Voltage Transducers Specifications Exceltronic II XLG AC Watt or Var Transducers WIRING DIAGRAMS FOR 0-1 mAdc AND 4-20 mAdc UNITS (Styles III & II Cases) Specifications 0-1 mAdc Units Triple Current or Voltage (Style II Case) Single Current or Voltage (Style III Case) AO CO - + - + - + 1 2 3 2 4 3 5 Voltage Input Nominal Range* Overload Continuous Burden/Element 6 8 11 10 9 CO AC INPUT AC INPUT 85–150 Vac 50–500 Hz 4 VA (maximum) at 120 V 85–150 Vac 50–500 Hz 4.5 VA (maximum) at 120 V ± (0.1% Reading + 0.05% RO) at 0–200% RO ± 0.2% of Output Range ± (0.1% Reading + 0.1% RO) at 0–200% RO ± 0.2% of Output Range Temperature Effect on Accuracy ±0.005% / ° C (typical) ±0.0075% / ° C (typical) ±0.0075% / ° C (typical) ±0.008% / ° C (typical) Operating Temperature Range -20° C to +70° C -20° C to +50° C -20° C to +60° C -20° C to +50° C 10 Vdc 15 Vdc 10 Vdc 15 Vdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750 Ω at 20 mAdc < 400 ms to 99% < 500 ms to 99% Compliance Voltage < 0.5% RO Output Ripple Peak Response Time Power Factor 4-20 mAdc Units Single Current or Voltage (Style III Case) Gain Zero Frequency Range ±2% of Reading (minimum) ± 20% of Reading (minimum) None Required ±5% of Zero Point (minimum) ±2% of Reading (minimum) ± 20% of Reading (minimum) None Required ±5% of Zero Point (minimum) 58–62 Hz 60 Hz ±0.25% RO, Noncumulative Stability (per year) Triple Current or Voltage (Style II Case) 0–95% Noncondensing Operating Humidity Isolation Complete (Input/Output/Power/Case) 2500 VRMS at 60 Hz Dielectric Withstand AO EXTERNAL AUX. POWER AC INPUT BO Surge Withstand CO - + - + - + Approximate Dimensions (excluding mounting plate) DC OUTPUT - Overrange with Linearity + 1 2 3 1 4 5 2 3 4 5 6 6A EXTERNAL AUX. POWER 8 9 10 11 2 lbs., 11 oz. (1.2 kg) 4.4" W x 3.9" D x 4.9" H (112 mm x 99 mm x 124 mm) Style II Case, see page 122 500–1000 Watts/Element 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. 6 7 ANSI/IEEE C37.90.1-1989 Maximum Net Weight DC DC DC OUTPUT OUTPUT OUTPUT < 500 ms to 99% ± 0.2% RO (maximum) PF Effect on Accuracy Standard Calibration Adjustments < 400 ms to 99% Any XLG BO AC INPUT 120 V 0–150 V 180 V 0.035 VA (maximum) at 120 V 20 mAdc for Standard Calibration Load AO 5A 0–10 A 15 A 250 A 0.3 VA (maximum) at 5 A ±1 mAdc for Standard Calibration Accuracy 12 4–20 mAdc Vars (Var Transducer) 20 mAdc for Standard Calibration 4 7 0 to ±1 mAdc Vars (Var Transducer) 4–20 mAdc Watts (Watt Transducer) ±1 mAdc for Standard Calibration Rated Output (RO) = 500 Watts or Vars/Element + 1 Nominal Range* Overload Continuous Overload 1 Second/Hour Burden/Element External Input Range Auxiliary Frequency Range Power Burden DC DC DC OUTPUT OUTPUT OUTPUT AC INPUT DC OUTPUT - BO Current Input 0 to ±1 mAdc Watts (Watt Transducer) *Total input not to exceed 200% of standard-calibration watts or vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts or vars on units with 4–20 mAdc output. Specifications subject to change without notice. 12 12A AO BO CO AC INPUT AC INPUT AC INPUT Adjust AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 102 SCI Transducer Cat 90-134(MTD) 103 102-103 1/9/02, 5:33 PM Ordering Procedure & Case Dimensions Exceltronic II XLG AC Watt or Var Transducers ORDERING PROCEDURE Wiring Diagrams Exceltronic II XLG AC Watt or Var Transducers WIRING DIAGRAMS FOR 0-1 mAdc AND 4-20 mAdc UNITS (Style II Case) XLG Model Number: XLG W 20 Transducer Type W = Watt R = Reactive (var) E 4 - A1 EXAMPLE: XLGW20E4-A1 Watt Transducer, 2 element, 120 Vac external auxiliary power, 4-20 mAdc output, 5 A/120 V input. Elements 10 = 1 Element 20 = 2 Element 25 = 21/2 Element 30 = 3 Element 2 Element, 3 Phase, 3 Wire, Delta 1 Element, Single Phase, 2 Wire L1 LINE L1 L2 - Output 1 = 0-1 mAdc 4 = 4-20 mAdc (unidirectional) 12 = 4-12-20 mAdc (bidirectional) L3 DC OUTPUT DC OUTPUT Auxiliary Power S = Self-Powered (internal auxiliary power) E = External Auxiliary Power (120 Vac std.) LINE L2 + - + 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 LOAD Input A=5A 1 = 120 V EXTERNAL AUX. POWER LOAD XLG Option 5 = 50 Hz (not UL Recognized) EXTERNAL AUX. POWER NOTE: Bottom terminal strip (7-12) omitted on S models. 21/2 Element, 3 Phase, 4 Wire, Wye 3 Element, 3 Phase, 4 Wire, Wye CASE DIMENSIONS (Style II Case) L1 1.14" (28.96 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) DC OUTPUT .75" (19.05 mm) 2 3 4 5 6 6A 2.00" (50.80 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) 4.15" (105.41 mm) 7 8 LINE L2 L3 N + 1 2 3 4 5 6 6A EXT. AUX. POWER .23" (5.84 mm) 1.50" (38.10 mm) L1 - + 1 N DC OUTPUT .094" RAD. (2.39 mm) 3.77" (95.76 mm) LINE L2 L3 9 10 11 EXT. AUX. POWER 12 12A 7 8 9 10 11 12 12A LOAD LOAD .07" (1.78 mm) 4.75" (120.65 mm) 5.25" (133.35 mm) Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams on page 101. Drawings not to scale. Adjust AMETEK® Power Instruments 104 SCI Transducer Cat 90-134(MTD) E Models: Shown. S Models: External aux. power not required. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 105 104-105 1/9/02, 5:33 PM Ordering Procedure & Case Dimensions Exceltronic II XLG AC Watt or Var Transducers ORDERING PROCEDURE Wiring Diagrams Exceltronic II XLG AC Watt or Var Transducers WIRING DIAGRAMS FOR 0-1 mAdc AND 4-20 mAdc UNITS (Style II Case) XLG Model Number: XLG W 20 E 4 - Transducer Type W = Watt R = Reactive (var) A1 EXAMPLE: XLGW20E4-A1 Watt Transducer, 2 element, 120 Vac external auxiliary power, 4-20 mAdc output, 5 A/120 V input. Elements 10 = 1 Element 20 = 2 Element 25 = 21/2 Element 30 = 3 Element 2 Element, 3 Phase, 3 Wire, Delta 1 Element, Single Phase, 2 Wire L1 LINE L1 L2 - Output 1 = 0-1 mAdc 4 = 4-20 mAdc (unidirectional) 12 = 4-12-20 mAdc (bidirectional) L3 DC OUTPUT DC OUTPUT Auxiliary Power S = Self-Powered (internal auxiliary power) E = External Auxiliary Power (120 Vac std.) LINE L2 + - + 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 LOAD Input A=5A 1 = 120 V EXTERNAL AUX. POWER LOAD XLG Option 5 = 50 Hz (not UL Recognized) EXTERNAL AUX. POWER NOTE: Bottom terminal strip (7-12) omitted on S models. 21/2 Element, 3 Phase, 4 Wire, Wye 3 Element, 3 Phase, 4 Wire, Wye CASE DIMENSIONS (Style II Case) L1 1.14" (28.96 mm) DC OUTPUT SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) .75" (19.05 mm) 2 3 4 5 6 6A 2.00" (50.80 mm) 4.15" (105.41 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) 7 8 LINE L2 L3 N + 1 2 3 4 5 6 6A EXT. AUX. POWER .23" (5.84 mm) 1.50" (38.10 mm) L1 - + 1 N DC OUTPUT .094" RAD. (2.39 mm) 3.77" (95.76 mm) LINE L2 L3 9 10 11 EXT. AUX. POWER 12 12A 7 8 9 10 11 12 12A LOAD LOAD .07" (1.78 mm) 4.75" (120.65 mm) 5.25" (133.35 mm) Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams on page 101. Drawings not to scale. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Adjust Fax: 585-454-7805 104 SCI Transducer Cat 90-134(MTD) E Models: Shown. S Models: External aux. power not required. 105 104-105 1/9/02, 5:33 PM Ordering Procedure & Case Dimensions Exceltronic II XLG Combined AC Watt/Var Transducers Specifications Exceltronic II XLG Combined AC Watt/Var Transducers ORDERING PROCEDURE 0 to ±1 mAdc Watts (Combined Watt/Var Transducer) Specifications Voltage Input Nominal Range* Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 15 A 250 A 0.3 VA (maximum) at 5 A Nominal Range* Overload Continuous Burden/Element 120 V 0–150 V 180 V 0.035 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden 4–20 mAdc Vars (Combined Watt/Var Transducer) 85–150 Vac 50–500 Hz 8 VA (maximum) at 120 V ±1 mAdc for Standard Calibration 20 mAdc for Standard Calibration ±(0.1% Reading + 0.05% RO) at 0–200% RO ±0.2% of Output Range ±(0.1% Reading + 0.1% RO) at 0–200% RO ±0.2% of Output Range Temperature Effect on Accuracy ± 0.005% / ° C (typical) ± 0.0075% / ° C (typical) ±0.0075% / ° C (typical) ±0.008% / ° C (typical) Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage Load 15 Vdc 10 Vdc 15 Vdc Any load from 0–750 Ω at 20 mAdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750Ω at 20 mAdc < 400 ms to 99% < 500 ms to 99% < 0.5% RO Response Time < 400 ms to 99% ±0.2% RO (maximum) PF Effect on Accuracy Standard Calibration Adjustments < 500 ms to 99% Any Power Factor Gain Zero ± 2% of Reading (minimum) ±20% of Reading (minimum) None Required ±5% of Zero Point (minimum) Frequency 30 E 1 - A1 - N EXAMPLE: XLGC30E1-A1-N Combined Watt/Var Transducer, 3 element, 120 Vac external auxiliary power, 0-1 mAdc output, 5 A/120 V input, nonisolated. Auxiliary Power S = Self-Powered (internal auxiliary power) E = External Auxiliary Power (120 Vac std.) Output 1 = 0-1 mAdc 4 = 4-20 mAdc (unidirectional) 12 = 4-12-20 mAdc (bidirectional) 15 = 4-20 mAdc Unidirectional (watts)/4-12-20 mAdc Bidirectional (vars) Input A=5A 1 = 120 V XLG 10 Vdc Any load from 0–10,000 Ω at 1 mAdc Output Ripple Peak C Elements 10 = 1 Element 20 = 2 Element 25 = 21/2 Element 30 = 3 Element 20 mAdc for Standard Calibration Accuracy XLG Transducer Type C = Combined Watt/Var ±1 mAdc for Standard Calibration Rated Output (RO) = 500 Watts or Vars/Element XLG Model Number: Options N = Nonisolated Outputs 5 = 50 Hz (not UL Recognized) ± 2% of Reading (minimum) ±20% of Reading (minimum) None Required ±5% of Zero Point (minimum) 60 Hz ±0.25% RO, Noncumulative Stability (per year) Operating Humidity CASE DIMENSIONS (Style IV Case) 0–95% Noncondensing Isolation Complete (Input/Output/Power/Case) Dielectric Withstand 2500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1-1989 Maximum Net Weight 1.14" (28.96 mm) 3 lbs., 5 oz. (1.5 kg) Approximate Dimensions (excluding mounting plate) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) 4.4" W x 3.9" D x 6.5" H (112 mm x 99 mm x 165 mm) Style IV Case, see page 123 500–1000 Watts/Element Overrange with Linearity 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. *Total input not to exceed 200% of standard-calibration watts and vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts and vars on units with 4–20 mAdc output. Specifications subject to change without notice. .75" (19.05 mm) .094" RAD. (2.39 mm) 2.00" (50.80 mm) Current Input 0 to ±1 mAdc Vars (Combined Watt/Var Transducer) 4–20 mAdc Watts (Combined Watt/Var Transducer) .23" (5.84 mm) 3.77" (95.76 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) 5.78" (146.81 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) 4.75" (120.65 mm) .07" (1.78 mm) 5.25" (133.35 mm) Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams on page 104. Drawings not to scale. AMETEK® Power Instruments 106 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 107 106-107 1/9/02, 5:33 PM Ordering Procedure & Case Dimensions Exceltronic II XLG Combined AC Watt/Var Transducers Specifications Exceltronic II XLG Combined AC Watt/Var Transducers ORDERING PROCEDURE 0 to ±1 mAdc Watts (Combined Watt/Var Transducer) Specifications Voltage Input Nominal Range* Overload Continuous Overload 1 Second/Hour Burden/Element 5A 0–10 A 15 A 250 A 0.3 VA (maximum) at 5 A Nominal Range* Overload Continuous Burden/Element 120 V 0–150 V 180 V 0.035 VA (maximum) at 120 V External Input Range Auxiliary Frequency Range Power Burden 4–20 mAdc Vars (Combined Watt/Var Transducer) 85–150 Vac 50–500 Hz 8 VA (maximum) at 120 V ±1 mAdc for Standard Calibration 20 mAdc for Standard Calibration ±(0.1% Reading + 0.05% RO) at 0–200% RO ±0.2% of Output Range ±(0.1% Reading + 0.1% RO) at 0–200% RO ±0.2% of Output Range Temperature Effect on Accuracy ± 0.005% / ° C (typical) ± 0.0075% / ° C (typical) ±0.0075% / ° C (typical) ±0.008% / ° C (typical) Operating Temperature Range -20° C to +60° C -20° C to +50° C -20° C to +60° C -20° C to +50° C Compliance Voltage Load 15 Vdc 10 Vdc 15 Vdc Any load from 0–750 Ω at 20 mAdc Any load from 0–10,000 Ω at 1 mAdc Any load from 0–750Ω at 20 mAdc < 400 ms to 99% < 500 ms to 99% < 0.5% RO Response Time < 400 ms to 99% ±0.2% RO (maximum) PF Effect on Accuracy Standard Calibration Adjustments < 500 ms to 99% Any Power Factor Gain Zero ± 2% of Reading (minimum) ±20% of Reading (minimum) None Required ±5% of Zero Point (minimum) Frequency 30 E 1 - A1 - N EXAMPLE: XLGC30E1-A1-N Combined Watt/Var Transducer, 3 element, 120 Vac external auxiliary power, 0-1 mAdc output, 5 A/120 V input, nonisolated. Auxiliary Power S = Self-Powered (internal auxiliary power) E = External Auxiliary Power (120 Vac std.) Output 1 = 0-1 mAdc 4 = 4-20 mAdc (unidirectional) 12 = 4-12-20 mAdc (bidirectional) 15 = 4-20 mAdc Unidirectional (watts)/4-12-20 mAdc Bidirectional (vars) Input A=5A 1 = 120 V XLG 10 Vdc Any load from 0–10,000 Ω at 1 mAdc Output Ripple Peak C Elements 10 = 1 Element 20 = 2 Element 25 = 21/2 Element 30 = 3 Element 20 mAdc for Standard Calibration Accuracy XLG Transducer Type C = Combined Watt/Var ±1 mAdc for Standard Calibration Rated Output (RO) = 500 Watts or Vars/Element XLG Model Number: Options N = Nonisolated Outputs 5 = 50 Hz (not UL Recognized) ± 2% of Reading (minimum) ±20% of Reading (minimum) None Required ±5% of Zero Point (minimum) 60 Hz ±0.25% RO, Noncumulative Stability (per year) Operating Humidity CASE DIMENSIONS (Style IV Case) 0–95% Noncondensing Isolation Complete (Input/Output/Power/Case) Dielectric Withstand 2500 VRMS at 60 Hz Surge Withstand ANSI/IEEE C37.90.1-1989 Maximum Net Weight 1.14" (28.96 mm) 3 lbs., 5 oz. (1.5 kg) Approximate Dimensions (excluding mounting plate) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) 4.4" W x 3.9" D x 6.5" H (112 mm x 99 mm x 165 mm) Style IV Case, see page 123 500–1000 Watts/Element Overrange with Linearity 500–600 Watts/Element 500–1000 Vars/Element 500–600 Vars/Element No additional error within voltage compliance. Reduce load resistance as required. *Total input not to exceed 200% of standard-calibration watts and vars on units with 0 to ±1 mAdc output. Total input not to exceed 120% of standard-calibration watts and vars on units with 4–20 mAdc output. Specifications subject to change without notice. .75" (19.05 mm) .094" RAD. (2.39 mm) 2.00" (50.80 mm) Current Input 0 to ±1 mAdc Vars (Combined Watt/Var Transducer) 4–20 mAdc Watts (Combined Watt/Var Transducer) .23" (5.84 mm) 3.77" (95.76 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) 5.78" (146.81 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) 4.75" (120.65 mm) 5.25" (133.35 mm) .07" (1.78 mm) Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams on page 104. Drawings not to scale. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 106 SCI Transducer Cat 90-134(MTD) 107 106-107 1/9/02, 5:33 PM Wiring Diagrams Exceltronic II XLG Combined AC Watt/Var Transducers How Accurate is your Cash Register? WIRING DIAGRAMS FOR 0-1 mAdc AND 4-20 mAdc ISOLATED UNITS (Style IV Case) Nonisolated units have the same connections as the Exceltronic Combined Watt/Var Transducers on page 48. 2 Element, 3 Phase, 3 Wire, Delta 1 Element, Single Phase, 2 Wire L1 LINE L1 L2 DC OUTPUT WATT - 2 3 4 5 6 6A + 1 2 3 4 5 6 6A EXTERNAL AUX. POWER 7 9 8 - 10 11 EXTERNAL AUX. POWER 12 12A DC OUTPUT VAR 7 + 2 3 5 6 12 12A The New Cash Register for the Industry! + JemStar is the metering solution for the new era of deregulation. At a time when old metering standards just won’t do, JemStar provides accuracy you can take to the bank. Put profit and loss control at your fingertips. A powerful meter, that exceeds industry standards, JEMSTAR is the new “cash register” for the industry. Accurate monitoring provides more data, and it allows you to provide customers with additional services and information. JEMSTAR can help turn your profits around. LOAD 3 Element, 3 Phase, 4 Wire, Wye LINE L2 L3 N 6A 6B L1 DC OUTPUT WATT 4 11 DC OUTPUT VAR - + 1 10 LINE L2 L3 N Metering for Today and for the Future + 1 2 3 1-888-880-JEM1 4 5 6 6A 6B EXT. AUX. POWER Simply Powerful EXT. AUX. POWER Watthour Accuracy: 0.07% Reading exceeds IEC 687 Class 0.2 The JEMSTAR accuracy is unparalleled in the industry. SCIENTIFIC COLUMBUS Contact Inputs (2) Channels Programmable for Pulse counter, Demand Synchronization, Status Input or TOU Rate Override. Thermal Demand Emulation, Demand Prediction Transformer Loss Compensation—TLC 7 8 9 10 11 12 12A 12B 7 8 9 Graphical Display 10 11 12 12A 12B Bi-Directional and 4 Quadrant Metering - + DC OUTPUT VAR LOAD - + DC OUTPUT VAR Per Phase and System Measurements Watts, Vars, VA, Q, Voltage, Current, PF, THD, Watthours, Varhours, VAhours, Qhours, Amphours LOAD Registers: Instantaneous, Consumption, Demand (Sliding & Fixed), Time of Peak, Average Power Factor, Coincident Demand, Coincident Power Factor, Cumulative Demand, Continuous Cumulative Demand, Simultaneous Communications I/R Port, RS-232, RS-485, Modem Instrumentation L1 DC OUTPUT WATT 9 8 LOAD 21/2 Element, 3 Phase, 4 Wire, Wye - L3 DC OUTPUT WATT + 1 LINE L2 In this industry an error rate as low as a fraction of a percent can mean the loss of hundreds of thousands of dollars. If you think of your meter as the “cash register” of your utility, you can envision the money you are losing through inaccurate measurements. Deregulation makes accurate metering your responsibility and even more important than ever before. S-Base, A-base, Switchboard Inputs and Outputs: Analog Outputs are fully Programmable for any instantaneous measurement. (3) channels of either 0-1 or 4-20 mA. Contact Outputs (4) Channels Programmable as Threshold Alarms, Site Monitoring Alarms, Energy Pulses, EOD Output or Demand Prediction Alarm Auto-ranging Voltage: 55-530 VAC Site Diagnostics include installation verification and on-going monitoring. www.rochester.com E Models: Shown. S Models: External aux. power not required. Adjust NOTE: Dynamic separation between the two analog outputs is limited to ±10 Vdc (±15 Vdc separation on E1 & S1 units). Headquarters 50 Fordham Road Wilmington, MA 01887 Tel: 978-988-4101 Fax: 978-988-4179 E-Mail: [email protected] 108 SCI Transducer Cat 90-134(MTD) 108-109 1/9/02, 5:33 PM 255 North Union Street Rochester, NY 14605 Tel: 585-263-7700 Fax: 585-454-7805 E-Mail: [email protected] 109 Wiring Diagrams Exceltronic II XLG Combined AC Watt/Var Transducers How Accurate is your Cash Register? WIRING DIAGRAMS FOR 0-1 mAdc AND 4-20 mAdc ISOLATED UNITS (Style IV Case) Nonisolated units have the same connections as the Exceltronic Combined Watt/Var Transducers on page 48. 2 Element, 3 Phase, 3 Wire, Delta 1 Element, Single Phase, 2 Wire L1 LINE L1 L2 DC OUTPUT WATT - 2 3 4 5 6 6A + 1 2 3 4 5 6 6A EXTERNAL AUX. POWER 7 9 8 - 10 11 EXTERNAL AUX. POWER 12 12A DC OUTPUT VAR 7 + 2 3 5 6 12 12A The New Cash Register for the Industry! + JemStar is the metering solution for the new era of deregulation. At a time when old metering standards just won’t do, JemStar provides accuracy you can take to the bank. Put profit and loss control at your fingertips. A powerful meter, that exceeds industry standards, JEMSTAR is the new “cash register” for the industry. Accurate monitoring provides more data, and it allows you to provide customers with additional services and information. JEMSTAR can help turn your profits around. LOAD 3 Element, 3 Phase, 4 Wire, Wye LINE L2 L3 N 6A 6B L1 DC OUTPUT WATT 4 11 DC OUTPUT VAR - + 1 10 LINE L2 L3 N Metering for Today and for the Future + 1 2 3 4 5 6 6A 6B EXT. AUX. POWER Simply Powerful EXT. AUX. POWER Watthour Accuracy: 0.07% Reading exceeds IEC 687 Class 0.2 The JEMSTAR accuracy is unparalleled in the industry. SCIENTIFIC COLUMBUS Thermal Demand Emulation, Demand Prediction Transformer Loss Compensation—TLC 7 8 9 10 11 12 12A 12B 7 8 9 Graphical Display 10 11 12 12A 12B Bi-Directional and 4 Quadrant Metering - + LOAD DC OUTPUT VAR - + DC OUTPUT VAR Per Phase and System Measurements Watts, Vars, VA, Q, Voltage, Current, PF, THD, Watthours, Varhours, VAhours, Qhours, Amphours LOAD Registers: Instantaneous, Consumption, Demand (Sliding & Fixed), Time of Peak, Average Power Factor, Coincident Demand, Coincident Power Factor, Cumulative Demand, Continuous Cumulative Demand, Simultaneous Communications I/R Port, RS-232, RS-485, Modem Inputs and Outputs: Analog Outputs are fully Programmable for any instantaneous measurement. (3) channels of either 0-1 or 4-20 mA. Contact Outputs (4) Channels Programmable as Threshold Alarms, Site Monitoring Alarms, Energy Pulses, EOD Output or Demand Prediction Alarm Contact Inputs (2) Channels Programmable for Pulse counter, Demand Synchronization, Status Input or TOU Rate Override. Instrumentation L1 DC OUTPUT WATT 9 8 LOAD 21/2 Element, 3 Phase, 4 Wire, Wye - L3 DC OUTPUT WATT + 1 LINE L2 In this industry an error rate as low as a fraction of a percent can mean the loss of hundreds of thousands of dollars. If you think of your meter as the “cash register” of your utility, you can envision the money you are losing through inaccurate measurements. Deregulation makes accurate metering your responsibility and even more important than ever before. S-Base, A-base, Switchboard Auto-ranging Voltage: 55-530 VAC Site Diagnostics include installation verification and on-going monitoring. E Models: Shown. S Models: External aux. power not required. Adjust NOTE: Dynamic separation between the two analog outputs is limited to ±10 Vdc (±15 Vdc separation on E1 & S1 units). AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 108 SCI Transducer Cat 90-134(MTD) 109 108-109 1/9/02, 5:33 PM SCIENTIFIC DC Watt Transducers COLUMBUS SCIENTIFIC Specifications, Ordering Procedure, & Wiring Diagram COLUMBUS DC WATT TRANSDUCERS The Model 6268 DC Watt Transducer is designed to monitor power in a dc power line and provide an analog output proportional to watts. Each unit is calibrated per customer requirement; dc current and voltage inputs must be specified prior to calibration. The current input can be direct from a customer-supplied 50 mVdc or 100 mVdc external shunt. The line-to-line voltage input connection can be made directly for voltages from 100 – 600 Vdc. An external multiplier resistance box is supplied for line-to-line voltages from 600 –1000 Vdc. DC Watt Transducer Specifications Current Input Nominal Range Overload Continuous Burden 50 mVdc or 100 mVdc from External Shunt (customer supplied) 0–150% of Rated Input ± 5 Vdc 10 mAdc (maximum—excluding shunts) Voltage Input Nominal Range Overload Continuous Burden 100–1000 Vdc (For input above 600 Vdc, an external multiplier resistance box is supplied.) Rated Voltage ±20% Rated Voltage + 30% 200 Ohms/Volt Nominal External Input Range Auxiliary Frequency Range Power Burden 105–130 Vac 60–500 Hz 6 VA Nominal ±1 mAdc at Nominal Inputs Rated Output (RO) 0 to ±1 mAdc Output Range ±0.75% RO ±0.5% RO Accuracy 50 mVdc Shunt 100 mVdc Shunt Scientific Columbus DC Watt Transducers have the same three-year warranty as the Exceltronic line. Temperature Effect on Accuracy ± 0.015% / ° C (excluding shunts) Operating Temperature Range -20° C to +60° C Compliance Voltage 10 Vdc 0–10,000 Ω Load Output Ripple Peak Features Applications ◆ High reliability ◆ DC rail systems ◆ Wide operating temperature range ◆ DC transmission lines ◆ Long-term stability Outputs ◆ 0 to ±1 mAdc ◆ DC control & monitoring ◆ Mining < 0.5% RO < 400 ms to 99% Response Time Standard Calibration Adjustments ± 2% of Reading (minimum) None Required Gain Zero ±0.2% RO, Noncumulative Stability (per year) Operating Humidity 0–95% Noncondensing Complete (Input/Output/Power/Case) Isolation Dielectric Withstand 2500 Vdc for 1 Second Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight 3 lbs., 14 oz. (1.8 kg) Approximate Dimensions (excluding mounting plate) 7.0" W x 3.7" D x 6.1" H (178 mm x 94 mm x 155 mm) Style I Case, see page 122 Specifications subject to change without notice. ORDERING PROCEDURE Model No. 6268 Scientific Columbus DC Watt Transducers perform well for monitoring dc power on electric rail systems. In a dc rail system, the catenary is energized to a specified dc level for operating the train. A Scientific Columbus DC Watt Transducer can derive an analog output signal proportional to watts to reflect the dc power delivered to the train. WIRING DIAGRAM (Style I Case) Please consult the factory if you require any options with the 6268 DC Watt Transducer. LINE Model 6268 DC Watt Transducer DC OUTPUT - 7 + 1 2 3 4 5 8 9 10 11 12 12A EXTERNAL AUX. POWER AMETEK® Power Instruments 110 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Instrumentation DC Rail Systems MV SHUNT LOAD Phone: 1-800-274-5368 Fax: 585-454-7805 111 110-111 1/9/02, 5:33 PM SCIENTIFIC DC Watt Transducers COLUMBUS SCIENTIFIC Specifications, Ordering Procedure, & Wiring Diagram COLUMBUS DC WATT TRANSDUCERS The Model 6268 DC Watt Transducer is designed to monitor power in a dc power line and provide an analog output proportional to watts. Each unit is calibrated per customer requirement; dc current and voltage inputs must be specified prior to calibration. The current input can be direct from a customer-supplied 50 mVdc or 100 mVdc external shunt. The line-to-line voltage input connection can be made directly for voltages from 100 – 600 Vdc. An external multiplier resistance box is supplied for line-to-line voltages from 600 –1000 Vdc. DC Watt Transducer Specifications Current Input Nominal Range Overload Continuous Burden 50 mVdc or 100 mVdc from External Shunt (customer supplied) 0–150% of Rated Input ± 5 Vdc 10 mAdc (maximum—excluding shunts) Voltage Input Nominal Range Overload Continuous Burden 100–1000 Vdc (For input above 600 Vdc, an external multiplier resistance box is supplied.) Rated Voltage ±20% Rated Voltage + 30% 200 Ohms/Volt Nominal External Input Range Auxiliary Frequency Range Power Burden 105–130 Vac 60–500 Hz 6 VA Nominal ±1 mAdc at Nominal Inputs Rated Output (RO) 0 to ±1 mAdc Output Range ±0.75% RO ±0.5% RO Accuracy 50 mVdc Shunt 100 mVdc Shunt Scientific Columbus DC Watt Transducers have the same three-year warranty as the Exceltronic line. Temperature Effect on Accuracy ± 0.015% / ° C (excluding shunts) Operating Temperature Range -20° C to +60° C Compliance Voltage 10 Vdc 0–10,000 Ω Load Output Ripple Peak Features Applications ◆ High reliability ◆ DC rail systems ◆ Wide operating temperature range ◆ DC transmission lines ◆ Long-term stability Outputs ◆ 0 to ±1 mAdc < 0.5% RO < 400 ms to 99% Response Time Standard Calibration Adjustments ± 2% of Reading (minimum) None Required Gain Zero ±0.2% RO, Noncumulative Stability (per year) Operating Humidity 0–95% Noncondensing Complete (Input/Output/Power/Case) Isolation ◆ DC control & monitoring Dielectric Withstand ◆ Mining 2500 Vdc for 1 Second Surge Withstand ANSI/IEEE C37.90.1 Maximum Net Weight 3 lbs., 14 oz. (1.8 kg) Approximate Dimensions (excluding mounting plate) 7.0" W x 3.7" D x 6.1" H (178 mm x 94 mm x 155 mm) Style I Case, see page 122 Specifications subject to change without notice. ORDERING PROCEDURE Model No. 6268 Scientific Columbus DC Watt Transducers perform well for monitoring dc power on electric rail systems. In a dc rail system, the catenary is energized to a specified dc level for operating the train. A Scientific Columbus DC Watt Transducer can derive an analog output signal proportional to watts to reflect the dc power delivered to the train. WIRING DIAGRAM (Style I Case) Please consult the factory if you require any options with the 6268 DC Watt Transducer. LINE Model 6268 DC Watt Transducer DC OUTPUT - 7 + 1 2 3 4 5 8 9 10 11 12 12A EXTERNAL AUX. POWER AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 MV SHUNT LOAD Fax: 585-454-7805 110 SCI Transducer Cat 90-134(MTD) Instrumentation DC Rail Systems 111 110-111 1/9/02, 5:33 PM SCIENTIFIC DC Voltage Isolation Amplifiers COLUMBUS The Model 6271A DC Voltage Isolation Amplifier is a linear amplifier designed to amplify dc shunted millivolt signals or dc voltages ranging from 0 –50 mV through 0 –1000 V, and provide complete isolation of the input signal. SCIENTIFIC Specifications COLUMBUS DC VOLTAGE ISOLATION AMPLIFIERS Specifications The output circuit is a hybrid amplifier operating in the transconductance mode to provide true current output. Load resistance variations from 0 –10,000 Ω have less than 0.1% effect on the output current. Current Input Units Only Nominal Range Overload Continuous Impedance Voltage Input Units Only Nominal Ranges Available Impedance 0–20 Vdc 21–1000 Vdc 0 to ±1 mAdc (DC Voltage Isolation Amplifier) — 0 to ±1 mAdc**† ±3 mAdc < 100 Ω 0 to ± 100 mVdc† 0 to ±50 mVdc thru 0 to ± 1000 Vdc (customer specified)† 5000 Ohms/Volt 1400 Ohms/Volt 108–132 Vac 58–62 Hz 2 VA Nominal 108–132 Vac 58–62 Hz 5 VA Nominal 0 to ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* External Input Range Auxiliary Frequency Range Power Burden Scientific Columbus DC Voltage Isolation Amplifiers have the same three-year warranty as the Exceltronic line. Rated Output (RO) ±0.5% RO at 25° C ±0.7% of Span Temperature Effect on Accuracy ±0.04% / ° C ±0.05% / ° C Operating Temperature Range -10° C to +70° C -10° C to +50° C Accuracy Features Applications Outputs Compliance Voltage 10 Vdc ◆ DC shunt inputs or dc voltage from 0–50 mV thru 0–1000 V ◆ 4000 Vdc input isolation ◆ Telemetering ◆ Recording devices ◆ 0 to ±1 mAdc Output Ripple Peak ◆ 1–5 or 1–3–5 mAdc Response Time ◆ A/D converters ◆ 4–20 or 4–12–20 mAdc Standard Calibration Adjustments ◆ 10–50 or 10–30–50 mAdc Stability (per year) See Table 2 on page 110. 0–10,000 Ω Load ◆ Complete isolation 6271A unit contributes < 0.25% RO at steady-state dc input 6271 unit contributes < 0.25% of Span at steady-state dc input < 400 ms to 99% < 1 Second to 99% ± 15% RO (minimum) ± 1% RO (minimum) ±20% of Span (minimum) ±5% of Zero Point (minimum) ±0.25% RO, Noncumulative ±0.4% of Span, Noncumulative Gain Zero Operating Humidity ◆ Filtered output Isolation Dielectric Withstand Maximum Net Weight Neutral-Current Sensor Warns of Magnetic Storms Approximate Dimensions (excluding mounting plate) 0–95% Noncondensing Input to (Output/Power/Case) Output/Power/Case Input to (Output/Power/Case) Output/Power/Case 4000 Vdc 1500 VRMS at 60 Hz 4000 Vdc 1500 VRMS at 60 Hz 2 lbs., 2 oz. (1 kg) 3 lbs., 8 oz. (1.6 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Other input ranges available; consult factory. † All inputs are zero-based spans. Specifications subject to change without notice. Instrumentation Off-the-shelf electronic components are used by a large investorowned utility to measure quasi-direct currents flowing in the neutrals of key transformers during solar-magnetic storms. The primary aim is to collect field data confirming the accuracy of recently developed models of dc current during geomagnetic activity. The geomagnetic current sensors interface with the utility’s SCADA system, so dispatchers can act accordingly when magnetic activity occurs. P-Option* (DC Voltage Isolation Amplifier) The neutral-current sensor consists of the Scientific Columbus Model 6271A DC Voltage Isolation Amplifier and a removable-yoke dc current sensor. The isolation amplifier filters out ac current and provides a precision 0 to ±1 mAdc bidirectional output to interface with the SCADA system. AMETEK® Power Instruments 112 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 113 112-113 1/9/02, 5:33 PM SCIENTIFIC DC Voltage Isolation Amplifiers COLUMBUS The Model 6271A DC Voltage Isolation Amplifier is a linear amplifier designed to amplify dc shunted millivolt signals or dc voltages ranging from 0 –50 mV through 0 –1000 V, and provide complete isolation of the input signal. SCIENTIFIC Specifications COLUMBUS DC VOLTAGE ISOLATION AMPLIFIERS Specifications The output circuit is a hybrid amplifier operating in the transconductance mode to provide true current output. Load resistance variations from 0 –10,000 Ω have less than 0.1% effect on the output current. Current Input Units Only Nominal Range Overload Continuous Impedance Voltage Input Units Only Nominal Ranges Available Impedance 0–20 Vdc 21–1000 Vdc 0 to ±1 mAdc (DC Voltage Isolation Amplifier) — 0 to ±1 mAdc**† ±3 mAdc < 100 Ω 0 to ± 100 mVdc† 0 to ±50 mVdc thru 0 to ± 1000 Vdc (customer specified)† 5000 Ohms/Volt 1400 Ohms/Volt 108–132 Vac 58–62 Hz 2 VA Nominal 108–132 Vac 58–62 Hz 5 VA Nominal 0 to ±1 mAdc for Standard Calibration 5, 20, or 50 mAdc for Standard Calibration, depending on selected output range* External Input Range Auxiliary Frequency Range Power Burden Scientific Columbus DC Voltage Isolation Amplifiers have the same three-year warranty as the Exceltronic line. Rated Output (RO) ±0.5% RO at 25° C ±0.7% of Span Temperature Effect on Accuracy ±0.04% / ° C ±0.05% / ° C Operating Temperature Range -10° C to +70° C -10° C to +50° C Accuracy Features Applications Outputs Compliance Voltage 10 Vdc ◆ DC shunt inputs or dc voltage from 0–50 mV thru 0–1000 V ◆ Telemetering ◆ Recording devices ◆ 0 to ±1 mAdc Output Ripple Peak ◆ 1–5 or 1–3–5 mAdc Response Time ◆ A/D converters ◆ 4–20 or 4–12–20 mAdc Standard Calibration Adjustments ◆ 10–50 or 10–30–50 mAdc Stability (per year) ◆ 4000 Vdc input isolation 6271 unit contributes < 0.25% of Span at steady-state dc input < 400 ms to 99% < 1 Second to 99% ± 15% RO (minimum) ± 1% RO (minimum) ±20% of Span (minimum) ±5% of Zero Point (minimum) ±0.25% RO, Noncumulative ±0.4% of Span, Noncumulative Gain Zero Isolation Dielectric Withstand Maximum Net Weight Neutral-Current Sensor Warns of Magnetic Storms Approximate Dimensions (excluding mounting plate) Rochester, New York 14605 Phone: 1-800-274-5368 Output/Power/Case Input to (Output/Power/Case) Output/Power/Case 4000 Vdc 1500 VRMS at 60 Hz 4000 Vdc 1500 VRMS at 60 Hz 2 lbs., 2 oz. (1 kg) 3 lbs., 8 oz. (1.6 kg) 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 7.0" W x 3.7" D x 5.6" H (178 mm x 94 mm x 142 mm) Style I Case, see page 122 * P-Option includes 1–5/1–3–5, 4–20/4–12–20, and 10–50/10–30–50 mAdc outputs. **Other input ranges available; consult factory. † All inputs are zero-based spans. The neutral-current sensor consists of the Scientific Columbus Model 6271A DC Voltage Isolation Amplifier and a removable-yoke dc current sensor. The isolation amplifier filters out ac current and provides a precision 0 to ±1 mAdc bidirectional output to interface with the SCADA system. 255 North Union Street 0–95% Noncondensing Input to (Output/Power/Case) Specifications subject to change without notice. Instrumentation Off-the-shelf electronic components are used by a large investorowned utility to measure quasi-direct currents flowing in the neutrals of key transformers during solar-magnetic storms. The primary aim is to collect field data confirming the accuracy of recently developed models of dc current during geomagnetic activity. The geomagnetic current sensors interface with the utility’s SCADA system, so dispatchers can act accordingly when magnetic activity occurs. Fax: 585-454-7805 112 SCI Transducer Cat 90-134(MTD) 6271A unit contributes < 0.25% RO at steady-state dc input Operating Humidity ◆ Filtered output AMETEK® Power Instruments See Table 2 on page 110. 0–10,000 Ω Load ◆ Complete isolation P-Option* (DC Voltage Isolation Amplifier) 113 112-113 1/9/02, 5:33 PM Ordering Procedure DC Voltage Isolation Amplifiers Ordering Procedure DC Voltage Isolation Amplifiers ORDERING PROCEDURE Table 3 Scaling Resistor (-RS) Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option -RS* Base Model No. Output Scaling Resistor Option #1 Table 1 Table 2 Table 3 0 to ±1 mAdc output Option #2 Input Table 4 Table 5 External Auxiliary Power Table 4 Other Options -RS 6271 PAN7 -SM Specify output voltage 100 mVdc Option -24 All units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. -SM -Z EXAMPLES: * You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. 6271A P-Option outputs Description Scaling Resistor Description 24 Vdc Loop-Powered (PA7 and PA7-B models only) (consult factory for specifications) Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units, except PAN-B models) 6271A-RS-SM-100 mVdc 0 to ±1 mAdc output DC Voltage Isolation Amplifier, resistor scaling (converts current output to voltage output), seismic brace, 0 to ±100 mVdc (std.) input calibration. Table 5 Input Selection 6271PAN7-RS-SM-100 mVdc 4-20 mAdc output DC Voltage Isolation Amplifier, resistor scaling (converts current output to voltage output), seismic brace, 0-100 mVdc (std.) input calibration. Type of Input Current Voltage Input Span 0 to ±1 mAdc 0 to ±50 mVdc thru 0 to ±1000 Vdc If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. All inputs for these units are zero-based spans. The standard input span is 0 to ±100 mVdc. All 0 to ±1 mAdc output units are inherently bidirectional; P-Option units are unidirectional or bidirectional as indicated in Table 2. Table 1 Base Model Number Selection WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) Model No. (0 to ±1 mAdc Units) 6271A 6271A DC Voltage Isolation Amplifier 0 to ±1 mAdc Units (P-Option Units) 6271 DC Voltage Isolation Amplifier P-Option Units 6271 EXTERNAL AUX. PWR. Table 2 Output Selection Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc PAN6-B PAN7-B PAN8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω PA6 PA7 PA8 PA6-B PA7-B PA8-B Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc + + 1 1 2 3 4 7 + Gain Adjust 5 2 3 4 5 6 6 8 7 DC INPUT 8 DC INPUT REF. REF. Zero Adjust + + UNIDIRECTIONAL BIDIRECTIONAL Adjust Caution: For 0 to ±1 mAdc units, external auxiliary power connects to terminals 1 & 2; for P-Option units, external auxiliary power connects to terminals 5 & 6. AMETEK® Power Instruments 114 SCI Transducer Cat 90-134(MTD) DC OUTPUT DC OUTPUT REF. Instrumentation 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. P-Option PAN6 PAN7 PAN8 Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω AUX. GAIN EXTERNAL AUX. POWER AUX. GAIN 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 115 114-115 1/9/02, 5:34 PM Ordering Procedure DC Voltage Isolation Amplifiers Ordering Procedure DC Voltage Isolation Amplifiers ORDERING PROCEDURE Table 3 Scaling Resistor (-RS) Option Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Option -RS* Base Model No. Output Scaling Resistor Option #1 Table 1 Table 2 Table 3 0 to ±1 mAdc output Option #2 Input Table 4 Table 5 External Auxiliary Power Table 4 Other Options -RS 6271 PAN7 -SM Specify output voltage 100 mVdc Option -24 All units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. -SM -Z EXAMPLES: * You must specify the desired output voltage: For 0 to ±1 mAdc units, specify range from 0 to ±10 Vdc. Load impedance is 1 MΩ/Vdc (minimum). For P-Option units, specify range from 0-15 Vdc (PAN models) or 0-40 Vdc (PA models). Load impedance is 200, 50, or 20 (kΩ/Vdc) (minimum) for units with outputs of 5, 20, or 50 mAdc, respectively. This information is not part of the model number, but must be provided to the factory when you place your order. 6271A P-Option outputs Description Scaling Resistor Description 24 Vdc Loop-Powered (PA7 and PA7-B models only) (consult factory for specifications) Seismic Brace (available with 0 to ±1 mAdc units) (consult factory if you desire this option with a P-Option unit) Zero-Based Output Calibration (ex.: PA7-Z = 0-20 mAdc) (available only with P-Option units, except PAN-B models) 6271A-RS-SM-100 mVdc 0 to ±1 mAdc output DC Voltage Isolation Amplifier, resistor scaling (converts current output to voltage output), seismic brace, 0 to ±100 mVdc (std.) input calibration. Table 5 Input Selection 6271PAN7-RS-SM-100 mVdc 4-20 mAdc output DC Voltage Isolation Amplifier, resistor scaling (converts current output to voltage output), seismic brace, 0-100 mVdc (std.) input calibration. Type of Input Current Voltage Input Span 0 to ±1 mAdc 0 to ±50 mVdc thru 0 to ±1000 Vdc If you require additional options not shown here, see Special Options on page 128. When ordering any special options, or more than three options, you must first consult the factory for pricing and delivery estimates. All inputs for these units are zero-based spans. The standard input span is 0 to ±100 mVdc. All 0 to ±1 mAdc output units are inherently bidirectional; P-Option units are unidirectional or bidirectional as indicated in Table 2. Table 1 Base Model Number Selection WIRING DIAGRAMS FOR 0 to ±1 mAdc UNITS (Style II Case) AND P-OPTION UNITS (Style I Case) Model No. (0 to ±1 mAdc Units) 6271A 6271A DC Voltage Isolation Amplifier 0 to ±1 mAdc Units (P-Option Units) 6271 DC Voltage Isolation Amplifier P-Option Units 6271 EXTERNAL AUX. PWR. Table 2 Output Selection Output Range 1-5 mAdc 4-20 mAdc 10-50 mAdc PAN6-B PAN7-B PAN8-B 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω PA6 PA7 PA8 PA6-B PA7-B PA8-B AMETEK® Power Instruments 255 North Union Street Maximum Open Circuit Voltage 30 Vdc 30 Vdc 30 Vdc 30 Vdc 30 Vdc 30 Vdc 1-5 mAdc 4-20 mAdc 10-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc 1-3-5 mAdc 4-12-20 mAdc 10-30-50 mAdc 40 Vdc/8000 Ω 40 Vdc/2000 Ω 30 Vdc/600 Ω 70 Vdc 70 Vdc 70 Vdc Rochester, New York 14605 Phone: 1-800-274-5368 + + 1 1 2 3 4 7 + Gain Adjust 5 2 3 4 5 6 6 8 7 DC INPUT 8 DC INPUT REF. Zero Adjust REF. + + UNIDIRECTIONAL BIDIRECTIONAL Adjust Caution: For 0 to ±1 mAdc units, external auxiliary power connects to terminals 1 & 2; for P-Option units, external auxiliary power connects to terminals 5 & 6. Fax: 585-454-7805 114 SCI Transducer Cat 90-134(MTD) DC OUTPUT DC OUTPUT REF. Instrumentation 0 to ±1 mAdc output is standard, and is specified by the Base Model Numbers. For outputs other than 0 to ±1 mAdc, indicate the appropriate P-Option in the "Output" position of the complete model number. P-Option PAN6 PAN7 PAN8 Compliance Voltage/ Maximum Load 15 Vdc/3000 Ω 15 Vdc/750 Ω 15 Vdc/300 Ω AUX. GAIN EXTERNAL AUX. POWER AUX. GAIN 115 114-115 1/9/02, 5:34 PM SCIENTIFIC DC Instrument Amplifiers COLUMBUS SCIENTIFIC Ordering Procedure & Wiring Diagrams COLUMBUS ORDERING PROCEDURE FOR DC INSTRUMENT AMPLIFIERS The Model 6181A DC Instrument Amplifier is a non-isolated unit with unmatched stability which provides a direct interface to low-level signals. Model No. 6181A Please consult the factory if you require any options with the 6181A DC Instrument Amplifier. Operating modes include: current-amplifier mode, voltageamplifier mode, transresistance mode, and transconductance mode. WIRING DIAGRAMS FOR DC INSTRUMENT AMPLIFIERS (Style II Case) Scientific Columbus DC Instrument Amplifiers have the same three-year warranty as the Exceltronic line. Current-Amplifier Mode Voltage-Amplifier Mode DC INPUT EXTERNAL AUX. POWER + + - + DC INPUT - + DC OUTPUT DC OUTPUT EXTERNAL AUX. POWER - R1 5 SPECIFICATIONS 1 2 3 4 5 6 7 3 IS CURRENT INPUT IL 6181 1 2 3 4 5 6 7 R1 Current Voltage 0–10 µA thru 0–5 mA 0–10 mV thru 0–8 V DC Output Limits (zero-based span) Current Voltage 0–10 mA (maximum) 0–8 V (maximum) Effective Input Impedance Current Voltage < 10 Ω >10 MΩ IL IS ± 0.5% of Maximum Output* Gain Stability ± 0.5% of Maximum Output* Zero Stability 20 µV / ° C (maximum), 5 µV / ° C (typical) Referenced to Input Response Time < 100 ms to 99% Maximum Net Weight * Must fall within input, output, and feedback resistance limits listed. R1 + R2 R1 ES 6 LOW INPUT IMPEDANCE (CURRENT INPUT) HIGH INPUT IMPEDANCE (VOLTAGE INPUT) HIGH OUTPUT IMPEDANCE (CURRENT OUTPUT) LOW OUTPUT IMPEDANCE (VOLTAGE OUTPUT) EXTERNAL AUX. POWER - 3 4 + DC OUTPUT EXTERNAL AUX. POWER 3 1 2 5 6 IS 5 7 CURRENT INPUT RK 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 = R1 + R2 R1 DC INPUT DC INPUT + EL ES Transconductance Mode 1 lb., 14 oz. (0.9 kg) Approximate Dimensions (excluding mounting plate) VOLTAGE OUTPUT + - DC OUTPUT + - 2 3 4 5 6 7 4 VOLTAGE INPUT 6 4 IL 3 1 VOLTAGE EL OUTPUT 6181 RK 5 CURRENT OUTPUT 6 RK 4 ES RK EL IS 6181 6 = RK ES = RK IL Instrumentation -10° C to +50° C = Transresistance Mode Dependent on externally selected components Operating Temperature Range EL 6 DC Linearity Accuracy/Temperature Effect/ Long-Term Stability 6181 R2 100–130 Vac 50–500 Hz 5 VA (maximum) DC Input Limits (zero-based span) VOLTAGE INPUT R2 7 R1 R2 R2 External Input Range Auxiliary Frequency Range Power Burden 3 4 R1 DC Instrument Amplifier Specifications 7 CURRENT OUTPUT 6 4 5 Specifications subject to change without notice. LOW INPUT IMPEDANCE (CURRENT INPUT) HIGH INPUT IMPEDANCE (VOLTAGE INPUT) LOW OUTPUT IMPEDANCE (VOLTAGE OUTPUT) HIGH OUTPUT IMPEDANCE (CURRENT OUTPUT) Zero Adjust AMETEK® Power Instruments 116 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 117 116-117 1/9/02, 5:34 PM SCIENTIFIC DC Instrument Amplifiers COLUMBUS SCIENTIFIC Ordering Procedure & Wiring Diagrams COLUMBUS ORDERING PROCEDURE FOR DC INSTRUMENT AMPLIFIERS The Model 6181A DC Instrument Amplifier is a non-isolated unit with unmatched stability which provides a direct interface to low-level signals. Model No. 6181A Please consult the factory if you require any options with the 6181A DC Instrument Amplifier. Operating modes include: current-amplifier mode, voltageamplifier mode, transresistance mode, and transconductance mode. WIRING DIAGRAMS FOR DC INSTRUMENT AMPLIFIERS (Style II Case) Scientific Columbus DC Instrument Amplifiers have the same three-year warranty as the Exceltronic line. Current-Amplifier Mode Voltage-Amplifier Mode DC INPUT EXTERNAL AUX. POWER + + - + DC INPUT - + DC OUTPUT DC OUTPUT EXTERNAL AUX. POWER - R1 5 SPECIFICATIONS 1 2 3 4 5 6 7 3 IS CURRENT INPUT IL 6181 1 2 3 4 5 6 7 R1 0–10 µA thru 0–5 mA 0–10 mV thru 0–8 V DC Output Limits (zero-based span) Current Voltage 0–10 mA (maximum) 0–8 V (maximum) Effective Input Impedance Current Voltage < 10 Ω >10 MΩ DC Linearity ± 0.5% of Maximum Output* Gain Stability ± 0.5% of Maximum Output* Zero Stability 20 µV / ° C (maximum), 5 µV / ° C (typical) Referenced to Input -10° C to +50° C Response Time < 100 ms to 99% Maximum Net Weight ES 6 HIGH INPUT IMPEDANCE (VOLTAGE INPUT) HIGH OUTPUT IMPEDANCE (CURRENT OUTPUT) LOW OUTPUT IMPEDANCE (VOLTAGE OUTPUT) EXTERNAL AUX. POWER + - 2 3 4 = R1 + R2 R1 Transconductance Mode + DC OUTPUT EXTERNAL AUX. POWER 3 1 EL ES DC INPUT DC INPUT 5 6 IS 5 7 CURRENT INPUT RK 4.4" W x 3.9" D x 4.7" H (112 mm x 99 mm x 119 mm) Style II Case, see page 122 * Must fall within input, output, and feedback resistance limits listed. R1 + R2 R1 LOW INPUT IMPEDANCE (CURRENT INPUT) 1 lb., 14 oz. (0.9 kg) Approximate Dimensions (excluding mounting plate) = Transresistance Mode Dependent on externally selected components Operating Temperature Range VOLTAGE OUTPUT + - DC OUTPUT + - 2 3 4 5 6 7 4 VOLTAGE INPUT 6 4 RK 6 = RK 6181 5 CURRENT OUTPUT 6 RK 4 ES RK EL IS IL 3 1 VOLTAGE EL OUTPUT 6181 ES = RK IL Instrumentation Accuracy/Temperature Effect/ Long-Term Stability EL 6 IL IS Current Voltage 6181 R2 100–130 Vac 50–500 Hz 5 VA (maximum) DC Input Limits (zero-based span) VOLTAGE INPUT R2 7 R1 R2 R2 External Input Range Auxiliary Frequency Range Power Burden 3 4 R1 DC Instrument Amplifier Specifications 7 CURRENT OUTPUT 6 4 5 Specifications subject to change without notice. LOW INPUT IMPEDANCE (CURRENT INPUT) HIGH INPUT IMPEDANCE (VOLTAGE INPUT) LOW OUTPUT IMPEDANCE (VOLTAGE OUTPUT) HIGH OUTPUT IMPEDANCE (CURRENT OUTPUT) Zero Adjust AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 116 SCI Transducer Cat 90-134(MTD) 117 116-117 1/9/02, 5:34 PM SCIENTIFIC Analog-to-Pulse Converters COLUMBUS Scientific Columbus analog-to-pulse converters are patented, high-accuracy, crystal-referenced devices for converting an analog signal into an integrated pulse output. Inputs may be from a watt, var, current, voltage, temperature, or other type of transducer for which integrated output information is required. Unidirectional and bidirectional models are available as well as multiple-channel (1, 2, or 3) models. The outputs can be either mercury-wetted relay or solid-state and can be fed into Scientific Columbus registers (see pages 118–119), pulse recorders, or other Form-A (2-wire) or Form-C (3-wire) receiving devices. A second, isolated Form-C relay may be added on some models. Isolated inputs are also available as an option on some models. Applications ◆ Accuracy to ± 0.1% of reading ◆ Converting any analog signal into a pulse signal ◆ Unidirectional or bidirectional ◆ Substations ◆ Generating stations ANALOG-TO-PULSE CONVERTERS Analog-to-Pulse Converters Specifications Current Input Voltage Input Models 6070, 6270, 6096, 6296, & SAF Range Overload Continuous 1 mAdc or ±1 mAdc Full Scale Models 6370, 6396 6570, & 6596 Range Overload Continuous 1 Vdc or ±1 Vdc Full Scale Outputs 0–200% of Full Scale Rating ±10 Vdc 85–135 Vac 50–500 Hz 2 VA Nominal Rated Output (RO) 2–14,000 cph Models 6070, 6370 6096, & 6396 Models 6270, 6296 6570, 6596, & SAF 2–900,000 cph ±(0.05% Reading + 0.005% RO) Models 6070, 6270, 6096, 6296, & SAF Models 6370, 6396, 6570, & 6596 ±(0.09% Reading + 0.01% RO) ±0.003% / ° C (maximum) Temperature Models 6070, 6270, Effect on 6096, 6296, & SAF Accuracy Models 6370, 6396, 6570, & 6596 ±0.005% / ° C (maximum) Operating Temperature Range Output ◆ 2–14,000 cph (relay) ◆ 2–900,000 cph (solid-state) 0–200% of Full Scale Rating ±10 mAdc External Input Range Auxiliary Frequency Range Power Burden Accuracy Scientific Columbus analog-to-pulse converters have the same three-year warranty as the Exceltronic line. Features SCIENTIFIC Specifications COLUMBUS -20° C to +70° C Models 6070, 6370, 6096, & 6396 Models 6270, 6296, 6570, 6596, & SAF Relay Contact Rating Form-C, SPDT, 3-Wire, Mercury-Wetted Relays Form-C, SPDT, 3-Wire, Solid-State 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. Relay maintains its position under power-failure conditions. Relay Contact Life One billion operations when operated within specifications. ◆ Form-C mercury-wetted relay or solid-state output Solid-State Output Contact Rating 28 Vdc (maximum). VCESAT: 1 Vdc (maximum) at 7 mAdc Standard Calibration Adjustment ±1% (minimum) ◆ Multichannel units available Operating Humidity ± 0.1% RO, Noncumulative Stability (per year) Isolation Dielectric Withstand 0-95% Noncondensing Input/Power/Case and Output/Power Case Input/Output (except counter-drive output) 1500 VRMS 1000 VRMS on KYZ Output Orientation Instrumentation Surge Withstand ANSI/IEEE C37.90.1 Models 6070, 6370, 6096, & 6396 Models 6270, 6296, 6570, 6596, & SAF Within 30° of Vertical/Horizontal Unlimited Maximum Net Weight 3 lbs., 2 oz. (1.4 kg) Approximate Dimensions (excluding mounting plate) 7.0" W x 3.7" D x 5.8" H (178 mm x 94 mm x 147 mm) Style I Case, see page 122 Specifications subject to change without notice. AMETEK® Power Instruments 118 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 119 118-119 1/9/02, 5:34 PM SCIENTIFIC Analog-to-Pulse Converters COLUMBUS SCIENTIFIC Specifications COLUMBUS ANALOG-TO-PULSE CONVERTERS Scientific Columbus analog-to-pulse converters are patented, high-accuracy, crystal-referenced devices for converting an analog signal into an integrated pulse output. Inputs may be from a watt, var, current, voltage, temperature, or other type of transducer for which integrated output information is required. Unidirectional and bidirectional models are available as well as multiple-channel (1, 2, or 3) models. The outputs can be either mercury-wetted relay or solid-state and can be fed into Scientific Columbus registers (see pages 118–119), pulse recorders, or other Form-A (2-wire) or Form-C (3-wire) receiving devices. A second, isolated Form-C relay may be added on some models. Isolated inputs are also available as an option on some models. Current Input Voltage Input Applications ◆ Accuracy to ± 0.1% of reading ◆ Converting any analog signal into a pulse signal ◆ Unidirectional or bidirectional ◆ Substations Models 6070, 6270, 6096, 6296, & SAF Range Overload Continuous 1 mAdc or ±1 mAdc Full Scale Models 6370, 6396 6570, & 6596 Range Overload Continuous 1 Vdc or ±1 Vdc Full Scale Outputs Rated Output (RO) 2–14,000 cph Models 6070, 6370 6096, & 6396 Models 6270, 6296 6570, 6596, & SAF 2–900,000 cph ±(0.05% Reading + 0.005% RO) Models 6070, 6270, 6096, 6296, & SAF Models 6370, 6396, 6570, & 6596 ±(0.09% Reading + 0.01% RO) ±0.003% / ° C (maximum) Temperature Models 6070, 6270, Effect on 6096, 6296, & SAF Accuracy Models 6370, 6396, 6570, & 6596 ±0.005% / ° C (maximum) Operating Temperature Range Output -20° C to +70° C Models 6070, 6370, 6096, & 6396 Models 6270, 6296, 6570, 6596, & SAF Relay Contact Rating Relay Contact Life ◆ Generating stations 0–200% of Full Scale Rating ±10 Vdc 85–135 Vac 50–500 Hz 2 VA Nominal ◆ 2–14,000 cph (relay) ◆ 2–900,000 cph (solid-state) 0–200% of Full Scale Rating ±10 mAdc External Input Range Auxiliary Frequency Range Power Burden Accuracy Scientific Columbus analog-to-pulse converters have the same three-year warranty as the Exceltronic line. Features Analog-to-Pulse Converters Specifications Form-C, SPDT, 3-Wire, Mercury-Wetted Relays Form-C, SPDT, 3-Wire, Solid-State 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. Relay maintains its position under power-failure conditions. One billion operations when operated within specifications. ◆ Form-C mercury-wetted relay or solid-state output Solid-State Output Contact Rating 28 Vdc (maximum). VCESAT: 1 Vdc (maximum) at 7 mAdc Standard Calibration Adjustment ±1% (minimum) ◆ Multichannel units available Operating Humidity ± 0.1% RO, Noncumulative Stability (per year) Isolation Dielectric Withstand Orientation Models 6070, 6370, 6096, & 6396 Models 6270, 6296, 6570, 6596, & SAF Maximum Net Weight Approximate Dimensions (excluding mounting plate) Input/Output (except counter-drive output) 1500 VRMS 1000 VRMS on KYZ Output Instrumentation Surge Withstand 0-95% Noncondensing Input/Power/Case and Output/Power Case ANSI/IEEE C37.90.1 Within 30° of Vertical/Horizontal Unlimited 3 lbs., 2 oz. (1.4 kg) 7.0" W x 3.7" D x 5.8" H (178 mm x 94 mm x 147 mm) Style I Case, see page 122 Specifications subject to change without notice. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 118 SCI Transducer Cat 90-134(MTD) 119 118-119 1/9/02, 5:34 PM Ordering Procedure Analog-to-Pulse Converters Wiring Diagrams Analog-to-Pulse Converters ORDERING PROCEDURE WIRING DIAGRAMS (Style I Case) Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Models 6070 & 6370 Base Model No. Mounting Orientation SAF-2 Table 1 -VTable 2 Add'l. Form-C Output(s) Option #1 -ATable 3 Counter Drive Option #2 -CTable 3 Model 6270 & 6570 EXTERNAL AUX. POWER DC INPUT Isolated Input Option #3 - + -ISTable 4 1 2 3 4 5 7 8 9 10 11 6 EXTERNAL AUX. POWER DC INPUT - + 6A 1 2 3 4 5 6 7 8 9 10 11 12 12A 6A Specify counts per hour EXAMPLES: SAF-2-V-A-C-IS 0 to -1 mAdc, 2-channel Analog-to-Pulse Converter with two standard Form-C solid-state outputs; vertical mounting; two additional Form-C mercury-wetted relays; two counter-drive outputs; isolated inputs. Table 1 Base Model Number Selection Model No. 6070 6270 6370 6570 6096 6296 6396 6596 SAF-1 SAF-2** SAF-3** Input 0-1 mAdc 0-1 mAdc 0-1 Vdc 0-1 Vdc 0 to ±1 mAdc 0 to ±1 mAdc 0 to ±1 Vdc 0 to ±1 Vdc 0 to -1 mAdc 0 to -1 mAdc 0 to -1 mAdc Configuration Unidirectional Unidirectional Unidirectional Unidirectional Bidirectional Bidirectional Bidirectional Bidirectional 1 Channel, Unidirectional 2 Channels, Unidirectional 3 Channels, Unidirectional 12 12A OUTPUT RELAY (FORM-C) SOLID-STATE OUTPUT (FORM-C) Models 6096 & 6396 Input Impedance 1 Ω (maximum) 1 Ω (maximum) 10 MΩ (minimum) 10 MΩ (minimum) 1 Ω (maximum) 1 Ω (maximum) 10 MΩ (minimum) 10 MΩ (minimum) 1 Ω (maximum) 1 Ω (maximum) 1 Ω (maximum) Output 1 Form-C Mercury-Wetted Relay 1 Form-C Solid-State Output 1 Form-C Mercury-Wetted Relay 1 Form-C Solid-State Output 2 Form-C Mercury-Wetted Relays 2 Form-C Solid-State Outputs 2 Form-C Mercury-Wetted Relays 2 Form-C Solid-State Outputs 1 Form-C Solid-State Output 2 Form-C Solid-State Outputs 3 Form-C Solid-State Outputs Model 6296 & 6596 EXTERNAL AUX. POWER DC INPUT CPH Range* 2-14,000 2-900,000 2-14,000 2-900,000 2-14,000 2-900,000 2-14,000 2-900,000 2-900,000 2-900,000 2-900,000 - + * You must specify the desired counts per hour. This information is not part of the model number, but must be provided to the factory when you place your order. 1 2 3 4 5 7 8 9 10 11 REVERSE 6 EXTERNAL AUX. POWER DC INPUT - + 6A 12 12A FORWARD 1 2 3 4 5 7 8 9 10 11 REVERSE 6 6A 12 12A FORWARD ** Standard SAF-2 and SAF-3 units have common positive input terminals. OUTPUT RELAYS (FORM-C) Table 2 Mounting Orientation Selection Description Horizontal Mounting (std.) (table, bench, or shelf) Vertical Mounting (wall mounting with vertical terminal blocks) These options apply only to units with mercury-wetted relays: Models 6070, 6370, 6096, 6396, or any SAF model with option -A. Models SAF-1, -2, -3 SOLID-STATE OUTPUTS (FORM-C) DC INPUTS -+-+-+ EXTERNAL AUX. POWER Table 3 Output Options Option -A -B -C Description Add'l. Form-C Mercury-Wetted Relay(s) Add'l. Form-C Solid-State Output(s) Counter-Drive Output(s) Table 4 Isolated Input Option Option -IS Description Isolated Inputs 2 1 These options apply only to SAF models. The number of relays, solid-state outputs, or counter drives corresponds to the number of channels in the unit. (Example: An SAF-3-A unit has three additional Form-C mercurywetted relays in addition to the three standard solid-state outputs.) 4 3 5 6 7 9 A C A B C A B B 10 11 12 13 14 15 C A B C 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Terminals 9, 11, & 13 (positive current input) are commoned internally. Requires negative current input for proper operation. This option applies only to SAF-model units and requires a Style V case. (See page 123 for case dimensions.) Please consult the factory if you require any additional options with Analog-to-Pulse Converters. OPTIONAL COUNTER-DRIVE OUTPUTS AMETEK® Power Instruments 120 SCI Transducer Cat 90-134(MTD) 8 Model SAF-3 is shown with options -A (additional mercury-wetted relays) and -C (counter drives). SAF-1 models have only the Channel "A" connections; SAF-2 models have only the Channel "A" and "B" connections. Instrumentation Option -H -V SOLID-STATE OUTPUTS (FORM-C) OPTIONAL OUTPUT RELAYS (FORM-C) 255 North Union Street Gain Adjust Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 121 120-121 1/9/02, 5:34 PM Ordering Procedure Analog-to-Pulse Converters Wiring Diagrams Analog-to-Pulse Converters ORDERING PROCEDURE WIRING DIAGRAMS (Style I Case) Specify by base model number and appropriate selection or option suffixes in the order shown in the following example. Models 6070 & 6370 Base Model No. Mounting Orientation SAF-2 Table 1 -VTable 2 Add'l. Form-C Output(s) Option #1 -ATable 3 Counter Drive Option #2 -CTable 3 Model 6270 & 6570 EXTERNAL AUX. POWER DC INPUT Isolated Input Option #3 - + -ISTable 4 1 2 3 4 5 7 8 9 10 11 6 EXTERNAL AUX. POWER DC INPUT - + 6A 1 2 3 4 5 6 7 8 9 10 11 12 12A 6A Specify counts per hour EXAMPLES: SAF-2-V-A-C-IS 0 to -1 mAdc, 2-channel Analog-to-Pulse Converter with two standard Form-C solid-state outputs; vertical mounting; two additional Form-C mercury-wetted relays; two counter-drive outputs; isolated inputs. Table 1 Base Model Number Selection Model No. 6070 6270 6370 6570 6096 6296 6396 6596 SAF-1 SAF-2** SAF-3** Input 0-1 mAdc 0-1 mAdc 0-1 Vdc 0-1 Vdc 0 to ±1 mAdc 0 to ±1 mAdc 0 to ±1 Vdc 0 to ±1 Vdc 0 to -1 mAdc 0 to -1 mAdc 0 to -1 mAdc 12 12A OUTPUT RELAY (FORM-C) SOLID-STATE OUTPUT (FORM-C) Models 6096 & 6396 Configuration Unidirectional Unidirectional Unidirectional Unidirectional Bidirectional Bidirectional Bidirectional Bidirectional 1 Channel, Unidirectional 2 Channels, Unidirectional 3 Channels, Unidirectional Input Impedance 1 Ω (maximum) 1 Ω (maximum) 10 MΩ (minimum) 10 MΩ (minimum) 1 Ω (maximum) 1 Ω (maximum) 10 MΩ (minimum) 10 MΩ (minimum) 1 Ω (maximum) 1 Ω (maximum) 1 Ω (maximum) Output 1 Form-C Mercury-Wetted Relay 1 Form-C Solid-State Output 1 Form-C Mercury-Wetted Relay 1 Form-C Solid-State Output 2 Form-C Mercury-Wetted Relays 2 Form-C Solid-State Outputs 2 Form-C Mercury-Wetted Relays 2 Form-C Solid-State Outputs 1 Form-C Solid-State Output 2 Form-C Solid-State Outputs 3 Form-C Solid-State Outputs Model 6296 & 6596 EXTERNAL AUX. POWER DC INPUT CPH Range* 2-14,000 2-900,000 2-14,000 2-900,000 2-14,000 2-900,000 2-14,000 2-900,000 2-900,000 2-900,000 2-900,000 - + * You must specify the desired counts per hour. This information is not part of the model number, but must be provided to the factory when you place your order. 1 2 3 4 5 7 8 9 10 11 REVERSE 6 EXTERNAL AUX. POWER DC INPUT - + 6A 12 12A FORWARD 1 2 3 4 5 7 8 9 10 11 REVERSE 6 6A 12 12A FORWARD ** Standard SAF-2 and SAF-3 units have common positive input terminals. OUTPUT RELAYS (FORM-C) Table 2 Mounting Orientation Selection Description Horizontal Mounting (std.) (table, bench, or shelf) Vertical Mounting (wall mounting with vertical terminal blocks) These options apply only to units with mercury-wetted relays: Models 6070, 6370, 6096, 6396, or any SAF model with option -A. Models SAF-1, -2, -3 SOLID-STATE OUTPUTS (FORM-C) DC INPUTS -+-+-+ EXTERNAL AUX. POWER Table 3 Output Options Option -A -B -C Description Add'l. Form-C Mercury-Wetted Relay(s) Add'l. Form-C Solid-State Output(s) Counter-Drive Output(s) Table 4 Isolated Input Option Option -IS 5 6 7 8 9 A C A B C A B B 10 11 12 13 14 15 C A B C Terminals 9, 11, & 13 (positive current input) are commoned internally. Requires negative current input for proper operation. This option applies only to SAF-model units and requires a Style V case. (See page 123 for case dimensions.) Please consult the factory if you require any additional options with Analog-to-Pulse Converters. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 OPTIONAL COUNTER-DRIVE OUTPUTS OPTIONAL OUTPUT RELAYS (FORM-C) Gain Adjust Fax: 585-454-7805 120 SCI Transducer Cat 90-134(MTD) 4 3 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Description Isolated Inputs AMETEK® Power Instruments 2 1 These options apply only to SAF models. The number of relays, solid-state outputs, or counter drives corresponds to the number of channels in the unit. (Example: An SAF-3-A unit has three additional Form-C mercurywetted relays in addition to the three standard solid-state outputs.) Model SAF-3 is shown with options -A (additional mercury-wetted relays) and -C (counter drives). SAF-1 models have only the Channel "A" connections; SAF-2 models have only the Channel "A" and "B" connections. Instrumentation Option -H -V SOLID-STATE OUTPUTS (FORM-C) 121 120-121 1/9/02, 5:34 PM SCIENTIFIC Registers COLUMBUS SCIENTIFIC Ordering Procedure & Wiring Diagrams COLUMBUS ORDERING PROCEDURE FOR REGISTERS The Models 6152 and 6153 Registers are used to display pulse outputs. They are designed for use with all Scientific Columbus pulse-output transducers and analog-to-pulse converters. They can also be used as remote registers for our JEM meters. Models 6172 and 6173 Registers are available for remote mounting of the can away from the counter. Consult the factory for more information on these products. Specify by base model number and appropriate option or selection suffixes in the order shown in the following example. Auxiliary Output Option #1 Base Model No. 6152R Mounting Configuration Option #2 D Table 1 P Table 2 External Auxiliary Power Mounting Orientation -V Table 3 Table 4 All units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Scientific Columbus registers have the same three-year warranty as the Exceltronic line. EXAMPLE: FEATURES ◆ Unidirectional or bidirectional ◆ 6-digit resettable or 7-digit nonresettable display ◆ Optional auxiliary relays and panel mounting SPECIFICATIONS Input External Auxiliary Power Single or Dual Form-C Relays Maximum Input Rate Open Contact Voltage Closed Contact Current Closed Contact Voltage Input Range Frequency Range Burden Accuracy Table 1 Base Model Number Selection Model No. 6152 6152R 6153 6153R Registers Specifications 3-Wire, SPDT, Dry Contact 15,000 cph VOC Maximum ≤ 15 Vdc ISC ≤ 10 mAdc Maximum VSC Closed ≤ 2.5 Vdc 108–132 Vac 50–500 Hz 1.5 VA Nominal at 120 V 6152RDP-V Single 6-digit Resettable Register, single auxiliary relay output, panel mounting, vertical mounting. Description Single 7-digit Register Single 6-digit Register Dual 7-digit Register Dual 6-digit Register Table 2 Auxiliary Output Options Configuration Nonresettable Resettable Nonresettable Resettable Option D DD Table 3 Mounting Configuration Options Table 4 Mounting Orientation Selection Option Std. (leave blank) P Option -H -V Description Wall or Shelf Mounting Panel Mounting Visual Output You must specify mounting orientation (vertical or horizontal) on units with D or DD options. WIRING DIAGRAMS FOR REGISTERS (Style I Case) -20° C to +60° C Single or Dual Registers, Figure Size 3/16" High, 6-Digit Resettable or 7-Digit Nonresettable Display Electrical Output (optional) Relay Contact Rating Single or Dual Isolated Relay Output: Form-C, 3-Wire, SPDT Models 6153, 6153R, 6153D, & 6153RD Models 6152, 6152R, 6152D, 6152RD, 6152DD, & 6152RDD Models 6153DD & 6153RDD 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. Relay Contact Life Y'F One billion operations when operated within specifications. Register Characteristics One count is registered for each transfer of the Form-C, 3-wire input. The register holds counts indefinitely under power-failure conditions and does not give false counts when the power is restored. Output Relay Characteristics INPUT PULSE CONTACT SOURCE INPUT PULSE CONTACT SOURCE Y Y' The normally open and normally closed contacts transfer their previous position for each transfer of the corresponding input relay. < 250 ms Operating Humidity 0–95% Noncondensing Isolation/ Visual Output Units Dielectric Withstand Electrical Output Units Input/Power/Case Input/Output ZF F K' Y'' 1000 VRMS at 60 Hz K K'R K'' Standard Optional Maximum Net Weight Wall and Shelf Mounting Panel Mounting EXTERNAL AUX. POWER 3 lbs., 6 oz. (1.5 kg) Approximate Dimensions (excluding mounting plate) 120 Vac Z'' EXTERNAL AUX. POWER K''F YR Z''F ZR Y'R ** 120 Vac Z'R R 3.7" W x 5.6" D x 7.0" H (94 mm x 142 mm x 178 mm) Style I Case, see page 122 EXTERNAL AUX. POWER * Relay outputs are present only on models with D or DD options. AMETEK® Power Instruments 122 255 North Union Street ** K'R 120 Vac 60 Hz R REGISTER Specifications subject to change without notice. Y'R K 60 Hz 60 Hz Y''F ZF F K'F Z'F YF * Z'F ZR R K K'F YR Z' 1500 VRMS at 60 Hz INPUT PULSE CONTACT SOURCE Y'F * Z Response Time YF F REGISTER Instrumentation F REGISTER REGISTER SCI Transducer Cat 90-134(MTD) Description Horizontal Mounting Vertical Mounting Exact (1 output for 1 input) Operating Temperature Range Mounting Configuration Description Single Auxiliary Relay Output (one relay per register) Dual Auxiliary Relay Output (two relays per register) R REGISTER Z'R Y''R K''R Z''R ** Dual relay outputs are present only on models with DD option. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 123 122-123 1/9/02, 5:34 PM SCIENTIFIC Registers COLUMBUS SCIENTIFIC Ordering Procedure & Wiring Diagrams COLUMBUS ORDERING PROCEDURE FOR REGISTERS The Models 6152 and 6153 Registers are used to display pulse outputs. They are designed for use with all Scientific Columbus pulse-output transducers and analog-to-pulse converters. They can also be used as remote registers for our JEM meters. Models 6172 and 6173 Registers are available for remote mounting of the can away from the counter. Consult the factory for more information on these products. Specify by base model number and appropriate option or selection suffixes in the order shown in the following example. Auxiliary Output Option #1 Base Model No. 6152R Mounting Configuration Option #2 D Table 1 P Table 2 External Auxiliary Power Mounting Orientation -V Table 3 Table 4 All units have 120 Vac external aux. power. Specify other voltage, if required: 69 Vac Aux., 240 Vac Aux., 277 Vac Aux., or 480 Vac Aux. Scientific Columbus registers have the same three-year warranty as the Exceltronic line. EXAMPLE: FEATURES ◆ Unidirectional or bidirectional ◆ 6-digit resettable or 7-digit nonresettable display ◆ Optional auxiliary relays and panel mounting Table 1 Base Model Number Selection SPECIFICATIONS Input External Auxiliary Power Model No. 6152 6152R 6153 6153R Registers Specifications Single or Dual Form-C Relays Maximum Input Rate Open Contact Voltage Closed Contact Current Closed Contact Voltage 3-Wire, SPDT, Dry Contact 15,000 cph VOC Maximum ≤ 15 Vdc ISC ≤ 10 mAdc Maximum VSC Closed ≤ 2.5 Vdc Input Range Frequency Range Burden 108–132 Vac 50–500 Hz 1.5 VA Nominal at 120 V Accuracy 6152RDP-V Single 6-digit Resettable Register, single auxiliary relay output, panel mounting, vertical mounting. Description Single 7-digit Register Single 6-digit Register Dual 7-digit Register Dual 6-digit Register Table 2 Auxiliary Output Options Configuration Nonresettable Resettable Nonresettable Resettable Option D DD Table 3 Mounting Configuration Options Table 4 Mounting Orientation Selection Option Std. (leave blank) P Option -H -V Description Wall or Shelf Mounting Panel Mounting Visual Output You must specify mounting orientation (vertical or horizontal) on units with D or DD options. WIRING DIAGRAMS FOR REGISTERS (Style I Case) -20° C to +60° C Single or Dual Registers, Figure Size 3/16" High, 6-Digit Resettable or 7-Digit Nonresettable Display Electrical Output (optional) Relay Contact Rating Models 6153, 6153R, 6153D, & 6153RD Models 6152, 6152R, 6152D, 6152RD, 6152DD, & 6152RDD Single or Dual Isolated Relay Output: Form-C, 3-Wire, SPDT Models 6153DD & 6153RDD 15 VA at 1 A (maximum) or 150 Vac/15 Vdc (maximum) with resistive load. Contact protection required for inductive loads. Relay Contact Life Y'F One billion operations when operated within specifications. Register Characteristics One count is registered for each transfer of the Form-C, 3-wire input. The register holds counts indefinitely under power-failure conditions and does not give false counts when the power is restored. Output Relay Characteristics INPUT PULSE CONTACT SOURCE INPUT PULSE CONTACT SOURCE Y Y' The normally open and normally closed contacts transfer their previous position for each transfer of the corresponding input relay. < 250 ms Operating Humidity 0–95% Noncondensing Isolation/ Visual Output Units Dielectric Withstand Electrical Output Units Input/Power/Case Input/Output ZF F K' Y'' 1000 VRMS at 60 Hz K K'R K'' Standard Optional Wall and Shelf Mounting Panel Mounting Maximum Net Weight EXTERNAL AUX. POWER 3 lbs., 6 oz. (1.5 kg) Z'' EXTERNAL AUX. POWER 60 Hz 3.7" W x 5.6" D x 7.0" H (94 mm x 142 mm x 178 mm) Style I Case, see page 122 Approximate Dimensions (excluding mounting plate) 255 North Union Street Rochester, New York 14605 120 Vac 60 Hz R REGISTER Specifications subject to change without notice. AMETEK® Power Instruments 120 Vac Phone: 1-800-274-5368 * Relay outputs are present only on models with D or DD options. K''F YR Z''F ZR Y'R ** Z'R Y''F ZF F K'F Z'F YF * Z'F ZR R K K'F YR Z' 1500 VRMS at 60 Hz INPUT PULSE CONTACT SOURCE Y'F * Z Response Time YF F REGISTER R Y'R K EXTERNAL AUX. POWER ** Instrumentation F REGISTER REGISTER K'R 120 Vac 60 Hz R REGISTER Z'R Y''R K''R Z''R ** Dual relay outputs are present only on models with DD option. Fax: 585-454-7805 122 SCI Transducer Cat 90-134(MTD) Description Horizontal Mounting Vertical Mounting Exact (1 output for 1 input) Operating Temperature Range Mounting Configuration Description Single Auxiliary Relay Output (one relay per register) Dual Auxiliary Relay Output (two relays per register) 123 122-123 1/9/02, 5:34 PM SCIENTIFIC Calibrator COLUMBUS SCIENTIFIC Specifications & Ordering Procedure COLUMBUS CALIBRATOR Scientific Columbus’ Model 6444 Portable Transducer Calibrator is designed for easy field verification and precision calibration of watt, var, voltage, and current transducers. With its solid-state measurement technology and programmability, it is ideal for field testing and calibration of power-monitoring transducers and supervisory control systems, and as a calibrator/ tester for receiving inspection. Function Tester and calibrator for ac watt, var, voltage, and current transducers Output Ranges 0–150 V 0–5 or 0–10 A 0–750 or 0–1500 W 0–750 or 0–1500 Vars Voltage Output Burden Current Output Burden This compact, rugged unit is completely self-contained and mounted in a portable carrying case. It is designed for easy, one-person operation. The operator is provided push-button selection of: • Test Mode • Current Range • Voltage Range • Test Variable • Number of Elements • Power Factor • Polarity Individual LCD indicating displays provide readouts of watts, vars, volts, and amps. The “% Error” meter displays percent-of-reading error. Test voltage from 0–150 Vac and current from 0–5 A or 0–10 A may be adjusted independently. During watt or var testing, volts and amps are displayed continuously. No external loads or accessory equipment are required. The null method of calibration and testing is used. An internal precision-reference standard and the transducer under test are subjected to identical input variables. The standard and test transducer output signals are compared algebraically. The difference between the two is displayed directly on a differential null meter, which reads deviations of up to ±19.99%. The Model 6444 Calibrator and this differential measurement technique offer distinct advantages: • The industry’s highest resolution and accuracy. • Consistentreadings.Variationsintestconditionsdo not influence the results. Calibrator Specifications • Calibration time is reduced through the one-person operation, with integrated hardware. • Allows testing over an infinite range of operating variables. Not confined to reading only specific • Eliminates test instrument cumulative errors and data cardinal points. transcription errors, since there’s no need to read and record many separate device data points. • Digitaldesignprovideseasieroperation,eliminates ambiguity of reading and meter reading parallax errors. 15 VA Nominal High Range Low Range 24 VA Nominal at 1 PF and 22 VA Nominal at 0.5 PF 6 VA Nominal at 1 PF and 3 VA Nominal at 0.5 PF Standard Output Signal 0–10 Vdc for zero to full scale of test quantity (V, A, W, Var) External Input Range Auxiliary Frequency Power Burden 108–132 Vac 60 Hz (50 Hz optional) 40–130 VA (dependent upon loading on voltage- and current-output circuits) ± 0.1% RO Accuracy of Internal Reference Accuracy of Digital Indicating Displays Volt, Amp, & Watt/Var Indicators ±0.15% of Reading (±1 digit) ±0.1% RO Accuracy of Standard Output Operating Temperature Range Transducer Signal Load 15° C to 35° C 1–99,999 Ω and Infinity, selected by thumbwheel digital-readout switches Load Power Factor Unity and 0.5 Lag (approximately) Operating Humidity 0–95% Noncondensing Displays Display Scaling Liquid Crystal, 31/2 Digit, High Contrast 0–150 0–5 or 0–10 0–750 or 0–1500 0 to ±19.99% Volts Amps Watts/Vars Error Terminations Five-way binding posts are mounted on the front panel of the instrument. Power receptable is on the rear of the case. Accessories No accessories are required for complete functional testing of transducers with 0–1 mAdc output. An optional offset adapter (Model 6242B) is available for use with transducers with outputs of 1–5/1–3–5, 4–20/4–12–20, or 10–50/10–30–50 mAdc. Packaging Wood-formica portable instrument case with carrying handle Maximum Net Weight 45 lbs., 8 oz. (20.7 kg) Average Shipping Weight 50 lbs. (22.7 kg) Approximate Dimensions 22" W x 9" D x 13" H (56 cm x 23 cm x 33 cm) Scientific Columbus’ Model 6444 Calibrator has the same three-year warranty as the Exceltronic line. Specifications subject to change without notice. ORDERING PROCEDURE Features Applications Outputs ◆ Transducer calibration ◆ 0–150 V ◆ Digitally programmable ◆ Receiving inspection ◆ 0–5 or 0–10 A ◆ Self-contained ◆ Field testing ◆ 0–750 or 0–1500 W ◆ Portable ◆ 0–750 or 0–1500 Vars ◆ One-person operation 6242B Description 6444 Calibrator, 60 Hz 6444 Calibrator, 50 Hz 6444 Calibrator, 60 Hz, 240 Vac External Auxiliary Power 6444 Calibrator, 50 Hz, 240 Vac External Auxiliary Power 6444 Calibrator, 60 Hz, Expanded Scale Calibrator with Internal Offset Adapter for Calibrating Transducers with 1–5/1–3–5 mAdc, 4–20/4–12–20 mAdc, or 10–50/10–30–50 mAdc Outputs Offset Adaptor (to be used with 6444 Calibrator) for Calibrating Transducers with 1–5/1–3–5 mAdc, 4–20/4–12–20 mAdc, or 10–50/10–30–50 mAdc Outputs ◆ No external loads required AMETEK® Power Instruments 124 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Reference ◆ Multifunction calibrator/tester Model No. 6444 6444-50 6444-240V Aux. 6444-50 240V Aux. 6444-EX 6444-P Fax: 585-454-7805 125 124-125 1/9/02, 5:34 PM SCIENTIFIC Calibrator COLUMBUS SCIENTIFIC Specifications & Ordering Procedure COLUMBUS CALIBRATOR Scientific Columbus’ Model 6444 Portable Transducer Calibrator is designed for easy field verification and precision calibration of watt, var, voltage, and current transducers. With its solid-state measurement technology and programmability, it is ideal for field testing and calibration of power-monitoring transducers and supervisory control systems, and as a calibrator/ tester for receiving inspection. Function Tester and calibrator for ac watt, var, voltage, and current transducers Output Ranges 0–150 V 0–5 or 0–10 A 0–750 or 0–1500 W 0–750 or 0–1500 Vars Voltage Output Burden Current Output Burden This compact, rugged unit is completely self-contained and mounted in a portable carrying case. It is designed for easy, one-person operation. The operator is provided push-button selection of: • Test Mode • Current Range • Voltage Range • Test Variable • Number of Elements • Power Factor • Polarity 15 VA Nominal High Range Low Range No external loads or accessory equipment are required. The null method of calibration and testing is used. An internal precision-reference standard and the transducer under test are subjected to identical input variables. The standard and test transducer output signals are compared algebraically. The difference between the two is displayed directly on a differential null meter, which reads deviations of up to ±19.99%. The Model 6444 Calibrator and this differential measurement technique offer distinct advantages: • Calibration time is reduced through the one-person operation, with integrated hardware. • Allows testing over an infinite range of operating variables. Not confined to reading only specific • Eliminates test instrument cumulative errors and data cardinal points. transcription errors, since there’s no need to read and record many separate device data points. • Digitaldesignprovideseasieroperation,eliminates ambiguity of reading and meter reading parallax errors. 24 VA Nominal at 1 PF and 22 VA Nominal at 0.5 PF 6 VA Nominal at 1 PF and 3 VA Nominal at 0.5 PF Standard Output Signal 0–10 Vdc for zero to full scale of test quantity (V, A, W, Var) External Input Range Auxiliary Frequency Power Burden 108–132 Vac 60 Hz (50 Hz optional) 40–130 VA (dependent upon loading on voltage- and current-output circuits) Accuracy of Internal Reference Individual LCD indicating displays provide readouts of watts, vars, volts, and amps. The “% Error” meter displays percent-of-reading error. Test voltage from 0–150 Vac and current from 0–5 A or 0–10 A may be adjusted independently. During watt or var testing, volts and amps are displayed continuously. • The industry’s highest resolution and accuracy. • Consistentreadings.Variationsintestconditionsdo not influence the results. Calibrator Specifications Accuracy of Digital Indicating Displays ± 0.1% RO Volt, Amp, & Watt/Var Indicators ±0.15% of Reading (±1 digit) Accuracy of Standard Output Operating Temperature Range Transducer Signal Load ±0.1% RO 15° C to 35° C 1–99,999 Ω and Infinity, selected by thumbwheel digital-readout switches Load Power Factor Unity and 0.5 Lag (approximately) Operating Humidity 0–95% Noncondensing Displays Display Scaling Liquid Crystal, 31/2 Digit, High Contrast Volts Amps Watts/Vars Error 0–150 0–5 or 0–10 0–750 or 0–1500 0 to ±19.99% Terminations Five-way binding posts are mounted on the front panel of the instrument. Power receptable is on the rear of the case. Accessories No accessories are required for complete functional testing of transducers with 0–1 mAdc output. An optional offset adapter (Model 6242B) is available for use with transducers with outputs of 1–5/1–3–5, 4–20/4–12–20, or 10–50/10–30–50 mAdc. Packaging Maximum Net Weight Wood-formica portable instrument case with carrying handle 45 lbs., 8 oz. (20.7 kg) Average Shipping Weight 50 lbs. (22.7 kg) Approximate Dimensions 22" W x 9" D x 13" H (56 cm x 23 cm x 33 cm) Scientific Columbus’ Model 6444 Calibrator has the same three-year warranty as the Exceltronic line. Specifications subject to change without notice. ORDERING PROCEDURE Applications Features Outputs ◆ Transducer calibration ◆ 0–150 V ◆ Digitally programmable ◆ Receiving inspection ◆ 0–5 or 0–10 A ◆ Self-contained ◆ Field testing ◆ 0–750 or 0–1500 W ◆ Portable ◆ 0–750 or 0–1500 Vars 6242B ◆ One-person operation ◆ No external loads required AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 124 SCI Transducer Cat 90-134(MTD) Description 6444 Calibrator, 60 Hz 6444 Calibrator, 50 Hz 6444 Calibrator, 60 Hz, 240 Vac External Auxiliary Power 6444 Calibrator, 50 Hz, 240 Vac External Auxiliary Power 6444 Calibrator, 60 Hz, Expanded Scale Calibrator with Internal Offset Adapter for Calibrating Transducers with 1–5/1–3–5 mAdc, 4–20/4–12–20 mAdc, or 10–50/10–30–50 mAdc Outputs Offset Adaptor (to be used with 6444 Calibrator) for Calibrating Transducers with 1–5/1–3–5 mAdc, 4–20/4–12–20 mAdc, or 10–50/10–30–50 mAdc Outputs Reference ◆ Multifunction calibrator/tester Model No. 6444 6444-50 6444-240V Aux. 6444-50 240V Aux. 6444-EX 6444-P 125 124-125 1/9/02, 5:34 PM Case Dimensions for Styles I, II, & III Cases SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) .44" FROM CASE - 4 SCREWS (11.18 mm) 1.02" (25.91 mm) Case Dimensions for Styles IV & V Cases .53" (13.46 mm) .25" (6.35 mm) 1.14" (28.96 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) 6.95" (176.53 mm) 5.02" (127.51 mm) .23" (5.84 mm) 3.77" (95.76 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 7.31" (185.67 mm) .53" (13.46 mm) .094" RAD. (2.39 mm) .23" (5.84 mm) 3.54" (89.92 mm) 2.00" (50.80 mm) 2.00" (50.80 mm) .094" RAD. (2.39 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) 7.83" (198.88 mm) .07" (1.78 mm) 5.78" (146.81 mm) 4.75" (120.65 mm) 5.25" (133.35 mm) Style I .07" (1.78 mm) Style IV 1.14" (28.96 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) .53" (13.46 mm) 1.82" (46.23 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) .34" FROM CASE - 4 SCREWS (8.64 mm) .25" (6.35 mm) .53" (13.46 mm) .23" (5.84 mm) 3.77" (95.76 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) 4.15" (105.41 mm) .07" (1.78 mm) .094" RAD. (2.39 mm) 3.00" (76.20 mm) 2.00" (50.80 mm) .094" RAD. (2.39 mm) 5.15" (130.81 mm) .23" (5.84 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.75" (120.65 mm) 5.25" (133.35 mm) 7.16" (181.86 mm) Style II 5.28" (134.11 mm) .10" (2.54 mm) 7.31" (185.67 mm) 7.83" (198.88 mm) Style V 1.50" (38.10 mm) 2.05" (52.07 mm) .53" (13.46 mm) .23" (5.84 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 3.07" (77.98 mm) .25" (6.35 mm) 3.50" (88.90 mm) Instrumentation SCREW HEAD PROTRUDES .25" .09" (2.29 mm) (TYP.) (6.35 mm) FROM CASE .46" .094" RAD. 2 SCREWS (11.68 mm) (2.39 mm) 3.53" (89.66 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.00" (101.60 mm) .07" (1.78 mm) Style III Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams. Drawings not to scale. Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams. Drawings not to scale. AMETEK® Power Instruments 126 SCI Transducer Cat 90-134(MTD) 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 127 126-127 1/9/02, 5:34 PM Case Dimensions for Styles I, II, & III Cases SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) .44" FROM CASE - 4 SCREWS (11.18 mm) 1.02" (25.91 mm) Case Dimensions for Styles IV & V Cases .53" (13.46 mm) .25" (6.35 mm) 1.14" (28.96 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) 6.95" (176.53 mm) 5.02" (127.51 mm) .23" (5.84 mm) 3.77" (95.76 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 7.31" (185.67 mm) .53" (13.46 mm) .094" RAD. (2.39 mm) .23" (5.84 mm) 3.54" (89.92 mm) 2.00" (50.80 mm) 2.00" (50.80 mm) .094" RAD. (2.39 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) 7.83" (198.88 mm) .07" (1.78 mm) 5.78" (146.81 mm) 4.75" (120.65 mm) 5.25" (133.35 mm) Style I .07" (1.78 mm) Style IV 1.14" (28.96 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) FROM CASE - 4 SCREWS .43" (10.92 mm) .25" (6.35 mm) .53" (13.46 mm) 1.82" (46.23 mm) SCREW HEAD PROTRUDES .09" (2.29 mm) (TYP.) .34" FROM CASE - 4 SCREWS (8.64 mm) .25" (6.35 mm) .23" (5.84 mm) 3.77" (95.76 mm) 4.15" (105.41 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.40" (111.76 mm) .07" (1.78 mm) .53" (13.46 mm) .094" RAD. (2.39 mm) 3.00" (76.20 mm) 2.00" (50.80 mm) .094" RAD. (2.39 mm) 5.15" (130.81 mm) .23" (5.84 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 1.50" (38.10 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.75" (120.65 mm) 5.25" (133.35 mm) 7.16" (181.86 mm) Style II 5.28" (134.11 mm) .10" (2.54 mm) 7.31" (185.67 mm) 7.83" (198.88 mm) Style V 1.50" (38.10 mm) 2.05" (52.07 mm) .53" (13.46 mm) .23" (5.84 mm) .36" DIA. (9.14 mm) 2 KEYSLOTS 3.07" (77.98 mm) .25" (6.35 mm) 3.50" (88.90 mm) Instrumentation SCREW HEAD PROTRUDES .25" .09" (2.29 mm) (TYP.) (6.35 mm) FROM CASE .46" .094" RAD. 2 SCREWS (11.68 mm) (2.39 mm) 3.53" (89.66 mm) .187" DIA. (4.75 mm) 2 MOUNTING HOLES 4.00" (101.60 mm) .07" (1.78 mm) Style III Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams. Drawings not to scale. AMETEK® Power Instruments 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Terminal strips shown for illustration purposes only. For exact terminal-strip configuration on specific units, see connection diagrams. Drawings not to scale. Fax: 585-454-7805 126 SCI Transducer Cat 90-134(MTD) 127 126-127 1/9/02, 5:34 PM Transducer Glossary Transducer Glossary Accuracy The degree of uncertainty with which a measured value agrees with the ideal value. Analog Output Shorting Relay (-CE) The shorting relay monitors the external auxiliary power signal on a watt, var, or watt/var unit. If the external auxiliary power deviates from a prespecified range (i.e., below 85 V), a relay contact closes, shorting the analog output. This helps prevent erroneous signals from the analog output due to low external auxiliary power. Apparent Power (volt-amps) The product of the applied voltage and current in an ac circuit. Apparent power, or volt-amps, is not the true power of the circuit because the power factor is not considered in the calculation. Auxiliary Power See External Auxiliary Power and Internal Auxiliary Power. Balanced Load Refers to an equal loading of the phases in a polyphase system (current and phase angle). Bidirectional (-B) A bidirectional unit allows measurements of inputs which flow in two directions, forward and reverse. A typical 4–12–20 mAdc device would have a zero setting at 12 and minimum and maximum settings at 4 and 20, respectively. The -B option applies only to P-Option units. Add -B to the PAN or PA designator to specify a bidirectional unit (for example, 4–12–20 mAdc versus 4–20 mAdc). Burden Load imposed by a transducer on the measured input circuit, expressed in volt-amps. Calibration Adjustment of a transducer so the output is within a specified range for particular values of the input. 50–200% Calibration Adjustment (voltage outputs) (-21) The common gain adjustment is ± 2%. When the wide-range adjustment is specified, the voltage output can be adjusted from 50–200% of its normal value. For example, if the normal Combination Unidirectional/Bidirectional Unit (-UB) The -UB option applies only to P-Option combined watt/var transducers. This option specifies a unidirectional output for watts (example: 4–20 mAdc) and a bidirectional output for vars (example: 4–12–20 mAdc). Compliance Voltage The specified maximum voltage that a transducer current output must be able to supply while maintaining the specified accuracy. Current Transformer (CT) Transformer used to accurately scale ac currents up or down, or to provide isolation. Generally used to scale large primary or bus currents to usable values for measuring purposes. Current Transformer Ratio (CTR) The ratio of primary amps divided by secondary amps. Dielectric The medium used to provide electrical isolation or separation. Dielectric Withstand The ability of a medium that is providing electrical isolation in a transducer to withstand an applied voltage for a specified time without flashover or puncture. Dielectric Withstand Voltage Test Test used to determine the ability of insulating materials and spacings to withstand specified overvoltages for a specified time (one minute unless otherwise stated) without flashover or puncture. Effective Power (watts) In ac measurements, effective power (measured in watts) equals the product of voltage, current, and power factor (the cosine of the phase angle between the current and the voltage). (Watts = EI cos(ø)) External Auxiliary Power (A2) The power required for correct operation of a transducer is supplied via an external auxiliary power source, rather than the line being measured. Unless otherwise specified, external auxiliary power is 120 Vac, 50–500 Hz. Exception: For average-sensing current and voltage transducers with 0–1 mAdc output, the A2 option specifies standard accuracy of 0.25% (default accuracy). Front Access (-FA) The -FA option allows for external calibration or access to test jack points on XLP transducers. 15 A Input (-7) The unit operates from 0–20 A. The standard calibration is 1500 W or vars per element input for 1 mAdc output. Frequency A measure of the number of complete cycles of a waveform per unit of time, specified in Hertz (Hz), or cycles per second. The following options refer to signal input frequency only: 25 A Input (-8) The unit operates from 0–30 A. The standard calibration is 2500 W or vars per element input for 1 mAdc output. The 25 A option requires a larger case and is not available on all transducers. 50 Hz Operation (-12) 400 Hz Operation (-6) Full Scale (F.S.) The specified maximum magnitude of the input quantity being measured that can be applied to a transducer without causing a change in performance beyond specified tolerance. Full Scale Output The specified maximum output value for which the stated accuracy condition applies. Impedance The total opposing force to the flow of current in an ac circuit. Input The standard transducer input is 5 A and 120 V; however, many other inputs are available: 69 V Input (-0) The unit operates from 0–75 V. The standard calibration is 250 W or vars per element input for 1 mAdc output. 240 V Input (-1) The unit operates from 0–300 V. The standard calibration is 1000 W or vars per element input for 1 mAdc output. 277 V Input (-9) The unit operates from 0–340 V. The standard calibration is 1200 W or vars per element input for 1 mAdc output. 480 V Input (-2) The unit operates from 0–600 V. The standard calibration is 2000 W or vars per element input for 1 mAdc output. 1 A Input (-3) The unit operates from 0–2 A. The standard calibration is 100 W or vars per element input for 1 mAdc output. 2.5 A Input (-4) The unit operates from 0–5 A. The standard calibration is 250 W or vars per element input for 1 mAdc output. 7.5 A Input (-11) The unit operates from 0–15 A. The standard calibration is 750 W or vars per element input for 1 mAdc output. 10 A Input (-5) The unit operates from 0–20 A. The standard calibration is 1000 W or vars per element input for 1 mAdc output. AMETEK® Power Instruments 128 SCI Transducer Cat 90-134(MTD) 255 North Union Street Internal Auxiliary Power (self-powered) (A4) The power required for correct operation of a transducer is supplied via the line being measured, and adds additional burden to the input. Exception: For average-sensing current and voltage transducers with 0–1 mAdc output, the A4 option specifies optional accuracy of 0.1%. Isolated Inputs (-IS) The -IS option applies only to Models SAF-2 and SAF-3 analogto-pulse converters. This option specifies that the positive current inputs are electrically isolated from each other. Isolated Outputs (for units with external auxiliary power) (-C2) Complete isolation between the watt and var outputs of combined watt/var transducers. The -C2 replaces A2 in the model number. Units with the -C2 option require a Style I case. This does not apply to XLG transducers. Isolated Outputs (for units with internal auxiliary power) (-C4) Complete isolation between the watt and var outputs of combined watt/var transducers. The -C4 replaces A4 in the model number. Units with the -C4 option require a Style I case. This does not apply to XLG transducers. Isolation To be electrically separate. A measure of the strength of the dielectric providing the electrical division or separation. KYZ A designator for the Form-C pulse initiator output from a transducer. Lag The condition where the current is delayed in time with respect to the voltage in an ac circuit (for example, an inductive load). Lead The condition where the current precedes in time with respect to the voltage in an ac circuit (for example, a capacitive load). Load The total impedance of all the items in the output circuit. Rochester, New York 14605 Phone: 1-800-274-5368 Reference 50–200% Calibration Adjustment (current outputs) (-20) The common gain adjustment is ± 2%. When the wide-range adjustment is specified, the current output can be adjusted from 50–200% of its normal value. For example, the normal output for a 500 W input is 1 mAdc when using a 1-element watt transducer. This unit could be adjusted to equate any output from 0.5 mAdc to 2 mAdc, for a 500 W input. The drawback to using the wide adjustment is that it makes precision calibration of the unit more difficult (a small turn of the potentiometer results in a large change in the output). conversion is 500 W in to 5 Vdc out, the unit could be adjusted to equate any output from 2.5 Vdc to 10 Vdc, for a 500 W input. The drawback to using the wide adjustment is that it makes precision calibration of the unit more difficult (a small turn of the potentiometer results in a large change in the output). These units have true voltage outputs, versus a milliamp output applied across a scaling resistor. Fax: 585-454-7805 129 128-129 1/9/02, 5:34 PM Transducer Glossary Transducer Glossary Accuracy The degree of uncertainty with which a measured value agrees with the ideal value. Analog Output Shorting Relay (-CE) The shorting relay monitors the external auxiliary power signal on a watt, var, or watt/var unit. If the external auxiliary power deviates from a prespecified range (i.e., below 85 V), a relay contact closes, shorting the analog output. This helps prevent erroneous signals from the analog output due to low external auxiliary power. Apparent Power (volt-amps) The product of the applied voltage and current in an ac circuit. Apparent power, or volt-amps, is not the true power of the circuit because the power factor is not considered in the calculation. Auxiliary Power See External Auxiliary Power and Internal Auxiliary Power. Balanced Load Refers to an equal loading of the phases in a polyphase system (current and phase angle). Bidirectional (-B) A bidirectional unit allows measurements of inputs which flow in two directions, forward and reverse. A typical 4–12–20 mAdc device would have a zero setting at 12 and minimum and maximum settings at 4 and 20, respectively. The -B option applies only to P-Option units. Add -B to the PAN or PA designator to specify a bidirectional unit (for example, 4–12–20 mAdc versus 4–20 mAdc). Burden Load imposed by a transducer on the measured input circuit, expressed in volt-amps. Calibration Adjustment of a transducer so the output is within a specified range for particular values of the input. 50–200% Calibration Adjustment (voltage outputs) (-21) The common gain adjustment is ± 2%. When the wide-range adjustment is specified, the voltage output can be adjusted from 50–200% of its normal value. For example, if the normal AMETEK® Power Instruments 255 North Union Street Combination Unidirectional/Bidirectional Unit (-UB) The -UB option applies only to P-Option combined watt/var transducers. This option specifies a unidirectional output for watts (example: 4–20 mAdc) and a bidirectional output for vars (example: 4–12–20 mAdc). Compliance Voltage The specified maximum voltage that a transducer current output must be able to supply while maintaining the specified accuracy. Current Transformer (CT) Transformer used to accurately scale ac currents up or down, or to provide isolation. Generally used to scale large primary or bus currents to usable values for measuring purposes. Current Transformer Ratio (CTR) The ratio of primary amps divided by secondary amps. Dielectric The medium used to provide electrical isolation or separation. Dielectric Withstand The ability of a medium that is providing electrical isolation in a transducer to withstand an applied voltage for a specified time without flashover or puncture. Dielectric Withstand Voltage Test Test used to determine the ability of insulating materials and spacings to withstand specified overvoltages for a specified time (one minute unless otherwise stated) without flashover or puncture. Effective Power (watts) In ac measurements, effective power (measured in watts) equals the product of voltage, current, and power factor (the cosine of the phase angle between the current and the voltage). (Watts = EI cos(ø)) External Auxiliary Power (A2) The power required for correct operation of a transducer is supplied via an external auxiliary power source, rather than the line being measured. Unless otherwise specified, external auxiliary power is 120 Vac, 50–500 Hz. Exception: For average-sensing current and voltage transducers with 0–1 mAdc output, the A2 option specifies standard accuracy of 0.25% (default accuracy). Rochester, New York 14605 Phone: 1-800-274-5368 Front Access (-FA) The -FA option allows for external calibration or access to test jack points on XLP transducers. 15 A Input (-7) The unit operates from 0–20 A. The standard calibration is 1500 W or vars per element input for 1 mAdc output. Frequency A measure of the number of complete cycles of a waveform per unit of time, specified in Hertz (Hz), or cycles per second. The following options refer to signal input frequency only: 25 A Input (-8) The unit operates from 0–30 A. The standard calibration is 2500 W or vars per element input for 1 mAdc output. The 25 A option requires a larger case and is not available on all transducers. 50 Hz Operation (-12) 400 Hz Operation (-6) Full Scale (F.S.) The specified maximum magnitude of the input quantity being measured that can be applied to a transducer without causing a change in performance beyond specified tolerance. Full Scale Output The specified maximum output value for which the stated accuracy condition applies. Impedance The total opposing force to the flow of current in an ac circuit. Input The standard transducer input is 5 A and 120 V; however, many other inputs are available: 69 V Input (-0) The unit operates from 0–75 V. The standard calibration is 250 W or vars per element input for 1 mAdc output. 240 V Input (-1) The unit operates from 0–300 V. The standard calibration is 1000 W or vars per element input for 1 mAdc output. 277 V Input (-9) The unit operates from 0–340 V. The standard calibration is 1200 W or vars per element input for 1 mAdc output. 480 V Input (-2) The unit operates from 0–600 V. The standard calibration is 2000 W or vars per element input for 1 mAdc output. 1 A Input (-3) The unit operates from 0–2 A. The standard calibration is 100 W or vars per element input for 1 mAdc output. 2.5 A Input (-4) The unit operates from 0–5 A. The standard calibration is 250 W or vars per element input for 1 mAdc output. 7.5 A Input (-11) The unit operates from 0–15 A. The standard calibration is 750 W or vars per element input for 1 mAdc output. 10 A Input (-5) The unit operates from 0–20 A. The standard calibration is 1000 W or vars per element input for 1 mAdc output. Exception: For average-sensing current and voltage transducers with 0–1 mAdc output, the A4 option specifies optional accuracy of 0.1%. Isolated Inputs (-IS) The -IS option applies only to Models SAF-2 and SAF-3 analogto-pulse converters. This option specifies that the positive current inputs are electrically isolated from each other. Isolated Outputs (for units with external auxiliary power) (-C2) Complete isolation between the watt and var outputs of combined watt/var transducers. The -C2 replaces A2 in the model number. Units with the -C2 option require a Style I case. This does not apply to XLG transducers. Isolated Outputs (for units with internal auxiliary power) (-C4) Complete isolation between the watt and var outputs of combined watt/var transducers. The -C4 replaces A4 in the model number. Units with the -C4 option require a Style I case. This does not apply to XLG transducers. Isolation To be electrically separate. A measure of the strength of the dielectric providing the electrical division or separation. KYZ A designator for the Form-C pulse initiator output from a transducer. Lag The condition where the current is delayed in time with respect to the voltage in an ac circuit (for example, an inductive load). Lead The condition where the current precedes in time with respect to the voltage in an ac circuit (for example, a capacitive load). Load The total impedance of all the items in the output circuit. Fax: 585-454-7805 128 SCI Transducer Cat 90-134(MTD) Internal Auxiliary Power (self-powered) (A4) The power required for correct operation of a transducer is supplied via the line being measured, and adds additional burden to the input. Reference 50–200% Calibration Adjustment (current outputs) (-20) The common gain adjustment is ± 2%. When the wide-range adjustment is specified, the current output can be adjusted from 50–200% of its normal value. For example, the normal output for a 500 W input is 1 mAdc when using a 1-element watt transducer. This unit could be adjusted to equate any output from 0.5 mAdc to 2 mAdc, for a 500 W input. The drawback to using the wide adjustment is that it makes precision calibration of the unit more difficult (a small turn of the potentiometer results in a large change in the output). conversion is 500 W in to 5 Vdc out, the unit could be adjusted to equate any output from 2.5 Vdc to 10 Vdc, for a 500 W input. The drawback to using the wide adjustment is that it makes precision calibration of the unit more difficult (a small turn of the potentiometer results in a large change in the output). These units have true voltage outputs, versus a milliamp output applied across a scaling resistor. 129 128-129 1/9/02, 5:34 PM Transducer Glossary Transducer Glossary 24 Vdc Loop-Powered (-24) This is a variation to the normal 4–20 mAdc output unit (PA7) or 4–12–20 mAdc output unit (PA7-B) that requires a 24 Vdc power supply to power the analog output. The transducer does not supply any current; it only controls the current flow in the output circuit. All -24 option units are self-powered, unless otherwise specified. Nominal The normal operating value. Overload The specified maximum magnitude of the input quantity being measured that can be applied to a transducer for a specified period of time without causing damage. Overrange The specified maximum operating point for which the stated accuracy condition applies. Peak to Peak The amplitude of the ac waveform from its positive peak to its negative peak. Phase Angle The angular displacement between a current and voltage waveform, measured in degrees or radians. P-Option P-Option refers to model number designators that specify certain outputs required for process control applications: 1–5 mAdc Output (-PAN6) Where a compliance rating of 3000 Ω or 15 Vdc is required. (-PA6) Where a compliance rating of 8000 Ω or 40 Vdc is required. (-P6 for XLP models) Where a compliance rating of 5000 Ω or 25 Vdc is required. 4–20 mAdc Output (-PAN7) Where a compliance rating of 750 Ω or 15 Vdc is required. (-PA7) Where a compliance rating of 2000 Ω or 40 Vdc is required. (-P7 for XLP models) Where a compliance rating of 1250 Ω or 25 Vdc is required. (-PA8) Where a compliance rating of 600 Ω or 30 Vdc is required. Range Nominal operating limits, specified by the lowest calibration point to the highest calibration point. Rated Output (RO) The output at standard calibration. Reactive Power (var) A component of apparent power (volt-amps) which does not produce any real power (watt) transfer (the sine of the phase angle between the current and the voltage). (Var = VA2 - W 2 or Var = EI sin (ø)) Special Calibration (-SC) All units can be calibrated to within a specified range. This information can be found in the “Other Options” table under the Ordering Procedure for most types of transducers. For some types of transducers, the information is in the Special Options section on page 128. Standard Calibration The nominal point at which a transducer is adjusted. Surge Withstand A measure of a transducer’s ability to withstand high-voltage, high-frequency transients of short duration without damage. Response Time The time for a transducer output signal to reach 99% of its final value after a step change in the applied input. Typically the response is an exponential curve. Ripple The magnitude of ac fluctuations in a dc signal, after filtering. Usually expressed as a percentage of rated output. Transducer A device for converting an electrical signal into a usable direct current or voltage for measurement purposes. Root-Mean-Square (RMS) The effective value of alternating current or voltage. The RMS value equates an ac signal to a dc signal that provides the same power transfer. Transformer Factor The product of the current transformer ratio (CTR) and the voltage transformer ratio (VTR). Also called the power ratio. Real Power (in an ac circuit) The average value of the instantaneous product of volts and amps over a fixed period of time. Unbalanced Loads Refers to an unequal loading of the phases in a polyphase system (current and/or phase angle). Unidirectional Unit A unidirectional unit allows inputs to be measured in one direction only. The stated output range (for example, 4–20 mAdc) indicates the minimum and maximum input levels. Voltage Transformer (VT) Transformer used to accurately scale ac voltages up or down, or to provide isolation. Generally used to scale large primary or bus voltages to usable values for measuring purposes. Voltage Transformer Ratio (VTR) The ratio of primary volts divided by secondary volts. Zero-Based Output Calibration (-Z) The -Z option applies only to P-Option units. The normal zero point—1, 4, or 10 mAdc—is replaced with a 0 mAdc zero point. For example, when a PAN7-Z unit is specified, the output range of the unit will be 0–20 mAdc instead of 4–20 mAdc. The -Z option is not available with PAN-B models. Scaling Resistor (-RS) The -RS option provides a scaled voltage output by the attachment of an external resistor to the transducer. The output is not a “true” voltage output and may be susceptible to loading errors. The resistor can be attached internally if specified by the user when ordering. Seismic Brace (-SM) The seismic brace is added to the transducer to keep its printed circuit boards stable. These are not seismically rated units. Self-Powered See Internal Auxiliary Power. Span The algebraic difference between the upper and lower values of a range. AMETEK® Power Instruments 130 SCI Transducer Cat 90-134(MTD) True RMS Volts The effective value of an ac signal. For a voltage signal, true RMS is a precise method of stating the voltage value regardless of the waveform distortion. An ac measurement which is equal in power transfer capability to a corresponding dc voltage. Stability The ability of a transducer to maintain its performance characteristics over a specified period of time. Surge Withstand Capability (SWC) Test (Ref. ANSI/IEEE C37.90.1) The SWC test wave is an oscillatory wave, frequency range of 1-1.5 MHz, voltage range of 2.5-3 kV crest value of first peak, envelope decaying to 50% of the crest value of the first peak in not less than 6 µs from the start of the wave. The source impedance is from 150-200 Ω. The test wave is to be applied to a test specimen at a repetition rate of not less than 50 tests per second for a period of not less than two seconds. (All voltage and time values refer to the open circuit condition of the generator.) Reading The expected output at a given input value. True RMS Amps The effective value of an ac signal. For an amp signal, true RMS is a precise method of stating the amp value regardless of waveform distortion. An ac measurement which is equal in power transfer capability to a corresponding dc current. Reference 10–50 mAdc Output (-PAN8) Where a compliance rating of 300 Ω or 15 Vdc is required. Power Factor (PF) The ratio of the effective power (watts) to the apparent power (volt-amps). Equal to the cosine of the phase angle for singlephase or 3-phase, 3-wire or 4-wire systems. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 131 130-131 1/9/02, 5:35 PM Transducer Glossary Transducer Glossary 24 Vdc Loop-Powered (-24) This is a variation to the normal 4–20 mAdc output unit (PA7) or 4–12–20 mAdc output unit (PA7-B) that requires a 24 Vdc power supply to power the analog output. The transducer does not supply any current; it only controls the current flow in the output circuit. All -24 option units are self-powered, unless otherwise specified. Nominal The normal operating value. Range Nominal operating limits, specified by the lowest calibration point to the highest calibration point. Rated Output (RO) The output at standard calibration. Overload The specified maximum magnitude of the input quantity being measured that can be applied to a transducer for a specified period of time without causing damage. Overrange The specified maximum operating point for which the stated accuracy condition applies. Peak to Peak The amplitude of the ac waveform from its positive peak to its negative peak. Phase Angle The angular displacement between a current and voltage waveform, measured in degrees or radians. P-Option P-Option refers to model number designators that specify certain outputs required for process control applications: 1–5 mAdc Output (-PAN6) Where a compliance rating of 3000 Ω or 15 Vdc is required. (-PA6) Where a compliance rating of 8000 Ω or 40 Vdc is required. (-P6 for XLP models) Where a compliance rating of 5000 Ω or 25 Vdc is required. 4–20 mAdc Output (-PAN7) Where a compliance rating of 750 Ω or 15 Vdc is required. (-PA7) Where a compliance rating of 2000 Ω or 40 Vdc is required. (-P7 for XLP models) Where a compliance rating of 1250 Ω or 25 Vdc is required. (-PA8) Where a compliance rating of 600 Ω or 30 Vdc is required. 255 North Union Street Reactive Power (var) A component of apparent power (volt-amps) which does not produce any real power (watt) transfer (the sine of the phase angle between the current and the voltage). (Var = VA2 - W 2 or Var = EI sin (ø)) Special Calibration (-SC) All units can be calibrated to within a specified range. This information can be found in the “Other Options” table under the Ordering Procedure for most types of transducers. For some types of transducers, the information is in the Special Options section on page 128. Stability The ability of a transducer to maintain its performance characteristics over a specified period of time. Standard Calibration The nominal point at which a transducer is adjusted. Surge Withstand A measure of a transducer’s ability to withstand high-voltage, high-frequency transients of short duration without damage. Response Time The time for a transducer output signal to reach 99% of its final value after a step change in the applied input. Typically the response is an exponential curve. Surge Withstand Capability (SWC) Test (Ref. ANSI/IEEE C37.90.1) The SWC test wave is an oscillatory wave, frequency range of 1-1.5 MHz, voltage range of 2.5-3 kV crest value of first peak, envelope decaying to 50% of the crest value of the first peak in not less than 6 µs from the start of the wave. The source impedance is from 150-200 Ω. The test wave is to be applied to a test specimen at a repetition rate of not less than 50 tests per second for a period of not less than two seconds. (All voltage and time values refer to the open circuit condition of the generator.) Ripple The magnitude of ac fluctuations in a dc signal, after filtering. Usually expressed as a percentage of rated output. Transducer A device for converting an electrical signal into a usable direct current or voltage for measurement purposes. Root-Mean-Square (RMS) The effective value of alternating current or voltage. The RMS value equates an ac signal to a dc signal that provides the same power transfer. Transformer Factor The product of the current transformer ratio (CTR) and the voltage transformer ratio (VTR). Also called the power ratio. Reading The expected output at a given input value. Real Power (in an ac circuit) The average value of the instantaneous product of volts and amps over a fixed period of time. True RMS Volts The effective value of an ac signal. For a voltage signal, true RMS is a precise method of stating the voltage value regardless of the waveform distortion. An ac measurement which is equal in power transfer capability to a corresponding dc voltage. Unbalanced Loads Refers to an unequal loading of the phases in a polyphase system (current and/or phase angle). Unidirectional Unit A unidirectional unit allows inputs to be measured in one direction only. The stated output range (for example, 4–20 mAdc) indicates the minimum and maximum input levels. Voltage Transformer (VT) Transformer used to accurately scale ac voltages up or down, or to provide isolation. Generally used to scale large primary or bus voltages to usable values for measuring purposes. Voltage Transformer Ratio (VTR) The ratio of primary volts divided by secondary volts. Zero-Based Output Calibration (-Z) The -Z option applies only to P-Option units. The normal zero point—1, 4, or 10 mAdc—is replaced with a 0 mAdc zero point. For example, when a PAN7-Z unit is specified, the output range of the unit will be 0–20 mAdc instead of 4–20 mAdc. The -Z option is not available with PAN-B models. Scaling Resistor (-RS) The -RS option provides a scaled voltage output by the attachment of an external resistor to the transducer. The output is not a “true” voltage output and may be susceptible to loading errors. The resistor can be attached internally if specified by the user when ordering. Seismic Brace (-SM) The seismic brace is added to the transducer to keep its printed circuit boards stable. These are not seismically rated units. Self-Powered See Internal Auxiliary Power. Span The algebraic difference between the upper and lower values of a range. Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 130 SCI Transducer Cat 90-134(MTD) True RMS Amps The effective value of an ac signal. For an amp signal, true RMS is a precise method of stating the amp value regardless of waveform distortion. An ac measurement which is equal in power transfer capability to a corresponding dc current. Reference 10–50 mAdc Output (-PAN8) Where a compliance rating of 300 Ω or 15 Vdc is required. AMETEK® Power Instruments Power Factor (PF) The ratio of the effective power (watts) to the apparent power (volt-amps). Equal to the cosine of the phase angle for singlephase or 3-phase, 3-wire or 4-wire systems. 131 130-131 1/9/02, 5:35 PM Special Options & Abbreviations AC & Calibration Formulas AC FORMULAS When ordering any Special Options, or more than three options, you must first consult the factory for pricing and delivery estimates. Alternating Current Formulas Single-Phase Two-Phase* Four-Wire Three-Phase Direct Current Formulas I x E x PF I x E x 2 x PF I x E x 1.73 x PF IxE 1000 1000 1000 1000 IxE IxEx2 I x E x 1.73 1000 1000 1000 I x E x % Eff. x PF I x E x 2 x % Eff. x PF I x E x 1.73 x % Eff. x PF I x E x % Eff. 746 746 746 746 Amps when Kilowatts are known kW x 1000 kW x 1000 kW x 1000 kW x 1000 E x PF 2 x E x PF 1.73 x E x PF E Amps when Kilovolt-Amps are known kVA x 1000 kVA x 1000 kVA x 1000 E 2xE 1.73 x E hp x 746 hp x 746 hp x 746 hp x 746 E x % Eff. x PF 2 x E x % Eff. x PF 1.73 x E x % Eff. x PF E x % Eff. To Find DC External Auxiliary Power If dc external auxiliary power is required, the following levels are available: 24 Vdc external auxiliary power (-JB) 48 Vdc external auxiliary power (-JC) 125 Vdc external auxiliary power (-JD) Extended Range (-ER) Special calibration levels that fall outside the normal calibration range. Fast Response (-FR) With fast response, the analog output responds faster to the change in input. The normal response time is 400 ms to 99%, but with the fast response option this changes to 50 ms or 100 ms to 99%. The change in response time results in an inversely proportional increase in output ripple. Consult factory for other response time requirements. Sepia Drawings (-DG) Drawings that can be used to reproduce blueprints. Frequency– 25 Hz Operation (-25) A measure of the number of complete cycles of a waveform per unit of time, specified in Hertz (Hz), or cycles per second. This option refers to signal input frequency only. Kilowatts Isolated VT Inputs (-AY) The -AY option specifies that the voltage inputs are isolated from each other on 3-element watt or var transducers. Kilovolt-Amps Special Calibration (Frequency Transducers) Frequency transducers can be calibrated within a specific range. Please consult the factory for special calibration requirements. Horsepower (output) Test Jack (-TJ) The test jack is connected in series with the analog output to allow testing without disconnecting the unit. The transducer is connected to the standard via the test jack to verify the circuit is working and to test the accuracy of the unit. The total resistance on the test jack plus the analog output cannot exceed the maximum load resistance of the transducer per its specification. The test jack is shorted when it is not in use. Amps when Horsepower is known STANDARD ABBREVIATIONS Symbol or Abbreviation ampere (amp)* alternating current additional adjustable/adjustment amperehour (amphour) auxiliary American wire gauge degree Celsius calibration counts per hour current transformer current transformer ratio direct current double-pole, double-throw external degree Fahrenheit full scale hour horsepower high voltage *Assumed here to be ac unless otherwise specified. Symbol or Abbreviation Hz Ke kHz kΩ kV kVA kvar kW kWh mA ms MΩ mV MW mW Ω PF PKe Unit or Term hertz secondary constant of energy (watthours**/ pulse) kilohertz kilohm kilovolt kilovolt-ampere kilovar kilowatt kilowatthour milliampere millisecond megohm millivolt megawatt milliwatt ohm power factor primary constant of energy (watthours**/pulse) Symbol or Abbreviation RFI RMS RO RPM RTD SPDT std. µA µs µV V VA VAh var varh VT VTR W Wh Unit or Term radio-frequency interference root-mean-square rated output revolutions per minute resistance temperature detector single-pole, double-throw standard microampere microsecond microvolt volt* volt-ampere (volt-amp) volt-amperehour (volt-amphour) volt-ampere reactive varhour voltage transformer voltage transformer ratio watt watthour CALIBRATION FORMULAS Definitions and Formulas for Calibration of Watt/Watthour, Var/Varhour, and Volt-Amp/Volt-Amphour Transducers ◆ Primary Calibration = CTR x VTR x Calibrating Watts (Vars or Volt-Amps) ◆ cph = counts per hour; where a count is a contact transfer of a 3-wire (KYZ) output device (mercury-wetted relay or solid-state). cph = Calibrating Watts (Vars or Volt-Amps) ÷ Ke cph = (Calibrating Watts (Vars or Volt-Amps) x CTR x VTR) ÷ PKe ◆ Ke = secondary constant in Wh/count (or other appropriate units) of a pulse-initiator output. Usually Wh/count of a 3-wire output where a count is any transition of the output-contact device. Ke = Watts ÷ cph ◆ PKe = primary constant of a pulse-initiator output. PKe = CTR x VTR x Ke **Watthours, varhours, or volt-amphours AMETEK® Power Instruments 132 SCI Transducer Cat 90-134(MTD) Reference A AC/ac add’l. adj. Ah aux. AWG °C cal. cph CT CTR DC/dc DPDT ext. °F F.S. h hp HV Unit or Term I = Line Current (Amps) % Eff. = Percent Efficiency kW = Kilowatts hp = Horsepower E = Volts Line to Line PF = Power Factor kVA = Kilovolt-Amps x = Multiply *For three-wire, two-phase circuits the current in the common conductor is 1.41 times that in either of the other two conductors. 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 133 132-133 1/9/02, 5:35 PM Special Options & Abbreviations AC & Calibration Formulas AC FORMULAS When ordering any Special Options, or more than three options, you must first consult the factory for pricing and delivery estimates. Alternating Current Formulas Single-Phase Two-Phase* Four-Wire Three-Phase Direct Current Formulas I x E x PF I x E x 2 x PF I x E x 1.73 x PF IxE 1000 1000 1000 1000 IxE IxEx2 I x E x 1.73 1000 1000 1000 I x E x % Eff. x PF I x E x 2 x % Eff. x PF I x E x 1.73 x % Eff. x PF I x E x % Eff. 746 746 746 746 Amps when Kilowatts are known kW x 1000 kW x 1000 kW x 1000 kW x 1000 E x PF 2 x E x PF 1.73 x E x PF E Amps when Kilovolt-Amps are known kVA x 1000 kVA x 1000 kVA x 1000 E 2xE 1.73 x E hp x 746 hp x 746 hp x 746 hp x 746 E x % Eff. x PF 2 x E x % Eff. x PF 1.73 x E x % Eff. x PF E x % Eff. To Find DC External Auxiliary Power If dc external auxiliary power is required, the following levels are available: 24 Vdc external auxiliary power (-JB) 48 Vdc external auxiliary power (-JC) 125 Vdc external auxiliary power (-JD) Extended Range (-ER) Special calibration levels that fall outside the normal calibration range. Fast Response (-FR) With fast response, the analog output responds faster to the change in input. The normal response time is 400 ms to 99%, but with the fast response option this changes to 50 ms or 100 ms to 99%. The change in response time results in an inversely proportional increase in output ripple. Consult factory for other response time requirements. Sepia Drawings (-DG) Drawings that can be used to reproduce blueprints. Frequency– 25 Hz Operation (-25) A measure of the number of complete cycles of a waveform per unit of time, specified in Hertz (Hz), or cycles per second. This option refers to signal input frequency only. Kilowatts Isolated VT Inputs (-AY) The -AY option specifies that the voltage inputs are isolated from each other on 3-element watt or var transducers. Kilovolt-Amps Special Calibration (Frequency Transducers) Frequency transducers can be calibrated within a specific range. Please consult the factory for special calibration requirements. Horsepower (output) Test Jack (-TJ) The test jack is connected in series with the analog output to allow testing without disconnecting the unit. The transducer is connected to the standard via the test jack to verify the circuit is working and to test the accuracy of the unit. The total resistance on the test jack plus the analog output cannot exceed the maximum load resistance of the transducer per its specification. The test jack is shorted when it is not in use. Amps when Horsepower is known STANDARD ABBREVIATIONS Symbol or Abbreviation ampere (amp)* alternating current additional adjustable/adjustment amperehour (amphour) auxiliary American wire gauge degree Celsius calibration counts per hour current transformer current transformer ratio direct current double-pole, double-throw external degree Fahrenheit full scale hour horsepower high voltage *Assumed here to be ac unless otherwise specified. AMETEK® Power Instruments Symbol or Abbreviation Hz Ke kHz kΩ kV kVA kvar kW kWh mA ms MΩ mV MW mW Ω PF PKe Unit or Term hertz secondary constant of energy (watthours**/ pulse) kilohertz kilohm kilovolt kilovolt-ampere kilovar kilowatt kilowatthour milliampere millisecond megohm millivolt megawatt milliwatt ohm power factor primary constant of energy (watthours**/pulse) Symbol or Abbreviation RFI RMS RO RPM RTD SPDT std. µA µs µV V VA VAh var varh VT VTR W Wh Unit or Term radio-frequency interference root-mean-square rated output revolutions per minute resistance temperature detector single-pole, double-throw standard microampere microsecond microvolt volt* volt-ampere (volt-amp) volt-amperehour (volt-amphour) volt-ampere reactive varhour voltage transformer voltage transformer ratio watt watthour CALIBRATION FORMULAS Definitions and Formulas for Calibration of Watt/Watthour, Var/Varhour, and Volt-Amp/Volt-Amphour Transducers ◆ Primary Calibration = CTR x VTR x Calibrating Watts (Vars or Volt-Amps) ◆ cph = counts per hour; where a count is a contact transfer of a 3-wire (KYZ) output device (mercury-wetted relay or solid-state). cph = Calibrating Watts (Vars or Volt-Amps) ÷ Ke cph = (Calibrating Watts (Vars or Volt-Amps) x CTR x VTR) ÷ PKe ◆ Ke = secondary constant in Wh/count (or other appropriate units) of a pulse-initiator output. Usually Wh/count of a 3-wire output where a count is any transition of the output-contact device. Ke = Watts ÷ cph ◆ PKe = primary constant of a pulse-initiator output. PKe = CTR x VTR x Ke **Watthours, varhours, or volt-amphours 255 North Union Street Rochester, New York 14605 Phone: 1-800-274-5368 Fax: 585-454-7805 132 SCI Transducer Cat 90-134(MTD) Reference A AC/ac add’l. adj. Ah aux. AWG °C cal. cph CT CTR DC/dc DPDT ext. °F F.S. h hp HV Unit or Term I = Line Current (Amps) % Eff. = Percent Efficiency kW = Kilowatts hp = Horsepower E = Volts Line to Line PF = Power Factor kVA = Kilovolt-Amps x = Multiply *For three-wire, two-phase circuits the current in the common conductor is 1.41 times that in either of the other two conductors. 133 132-133 1/9/02, 5:35 PM Terms & Conditions ◆ Ordering Information & Technical Assistance If you need help with your order, or have technical questions, a transducer specialist is available to answer your questions. Call us: 8 AM to 5 PM EST, Monday through Friday, 1-800-274-5368 (U.S. and Canada) Fax us: 24 hours a day, seven days a week, 585-454-7805 ◆ Quotes Contact your local representative for pricing and delivery estimates. ◆ Payment Terms Standard terms of payment are net thirty (30) days from date of invoice. ◆ Warranty Seller warrants its Equipment to meet applicable specifications, if any, and to be free from defects in material and workmanship for a period of one (1) year from date of shipment to the original Purchaser, provided that such warranty shall be for a period of (a) two (2) years from the date of shipment for the Exceltronic® II XLG product and (b) three (3) years from the date of shipment for the Exceltronic® XL and Digilogic™ DL products. Upon receipt of prompt notice from Purchaser, referencing the order number and detailing the claimed nonconformity or defect, Seller shall, at its option, repair or replace the Equipment. Equipment returned to Seller will only be accepted with a Returned Materials Authorization number (“RMA”) issued by Seller or one of its authorized representatives. Inbound shipping charges to Seller’s factory in Rochester, New York, or other designated facility, are the responsibility of Purchaser. Normal shipping charges for the return to Purchaser of repaired or replacement Equipment shall be the responsibility of the Seller (North American points only). Repair or replacement of the Equipment in the manner described above is the exclusive warranty remedy and shall constitute complete fulfillment of all Seller’s liabilities for breach of this Warranty. Seller assumes no responsibility hereunder for any Equipment damage or failure caused by (a) improper installation, operation, and maintenance of the Equipment, or (b) normal wear and tear on disposable and/or consumable parts. This Warranty shall be void in the event of unauthorized modification or servicing of the Equipment. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES OF QUALITY, WHETHER EXPRESSED OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE). In no event shall Seller be liable hereunder for any special, indirect, incidental, or consequential damages including but not limited to loss of revenue or production. Exceltronic® is a Registered Trademark of Scientific Columbus Co. Copyright © 1995 Scientific Columbus Co. All rights reserved. ◆ Delivery Standard delivery is via UPS, F.O.B. shipping point (Rochester, New York). Express delivery can be made via either UPS or Federal Express. Shipments over 150 pounds are made via Yellow Freight or Overnight Transportation. All delivery charges are automatically added to your invoice. ◆ Returns If it is necessary to return Scientific Columbus products for repair or calibration, contact either your local representative or the factory at 1-800-274-5368 (U.S. and Canada). 134 SCI Transducer Cat 90-134(MTD) 134 1/9/02, 5:35 PM Ametek Transducer Comp MTD1 WORLD HEADQUARTERS 255 North Union Street Rochester, NY 14605 Toll Free: +1.800.950.6686 Tel: +585.263.7700 Fax: +585.454.7805 1/9/02 5:10 PM EUROPEAN HEADQUARTERS UK +44.770.280.9377 [email protected] Page 1 ASIA PACIFIC HEADQUARTERS Singapore +65.6484.2388 [email protected] AMETEK INSTRUMENTS INDIA PVT. LTD. Bengaluru +91.80.6782.3252 [email protected] WEBSITE www.ametekpower.com EMAIL [email protected]