ST.05.00.00.a MILLS BUILDING FOUNDATIONS IFC (REVIEW)

Anuncio
26-JAN-2022
0
www.vestalcorporation.com
T: 314.439.9900
F: 314.439.9906
CORPORATION
IK
PK APROBO:
DIBUJO:
KEY PLAN (PLANO CLAVE)
21023-050000a-S001
TRUE
NORTH
ESCALA:
F
mm
M
DIBUJO NO:
A
COTAS:
PROJECT LOCATION
(UBICACIÓN DEL PROYECTO)
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
HOJA DE PORTADA / VISTA EN 3D
NOTAS GENERALES
NOTAS GENERALES
PLANO DE CIMENTACIÓN - MOLIENDA
PLANTA DE ARREGLO DE ANCLAJES
ELEVACIONES DE CIMENTACIÓN
CIMENTACION SECCIONES Y DETALLES
DETALLES TÍPICOS
DETALLES TÍPICOS
TABLAS
DETALLES Y TABLA DE ANCLAJES
COVER SHEET / 3D VIEW
(HOJA DE PORTADA / VISTA EN 3D)
COVER SHEET / 3D VIEW
GENERAL NOTES
GENERAL NOTES
FOUNDATION PLAN - MILLS
ANCHOR LAYOUT PLAN
FOUNDATION ELEVATIONS
FOUNDATION SECTIONS AND DETAILS
TYPICAL DETAILS
TYPICAL DETAILS
SCHEDULES
ANCHOR SCHEDULE AND DETAILS
NOMBRE DE DIBUJO
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
0
0
0
0
0
0
0
0
0
0
0
DRAWING NAME
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
STRUCTURAL
21023-050000a-S001
21023-050000a-S002
21023-050000a-S003
21023-050000a-S100
21023-050000a-S101
21023-050000a-S200
21023-050000a-S300
21023-050000a-S500
21023-050000a-S501
21023-050000a-S600
21023-050000a-S601
REV
TITULO DEL PLANO:
NO. DE PLANO (SHEET NUMBER)
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
LISTA DE DIBUJOS (LIST OF DRAWINGS) - CIMENTACIÓNES (FOUNDATION)
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
PRINTED: 1/28/2022 14:04:27
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
S001
DIAGEO - EL CHARCON - ELEVATE II PROJECT
1
3D VIEW FOUNDATION
(CIMENTACIÓN VISTA EN 3D)
FIRMA DE DISEÑO / DESIGN FIRM
CLIENTE / CLIENT
FASE DISEÑO / DESIGN PHASE
REVISIONES / REVISION
REVISIONES / REVISIONS
FECHA / DATE
DR - ST.05.00.00.a - MILLS BUILDING - FOUNDATIONS
DR - ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
IFC (REVIEW)
DIAGEO - EL CHARCON - ELEVATE II PROJECT
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
.
ALL OFFSITE BORROW MATERIAL MUST BE FROM A LICENSED AND OWNER-APPROVED SITE.
14.
ALL EXCAVATION SOILS SHALL BE TESTED BY THE OWNER PRIOR TO REMOVAL FROM THE SITE.
THE DETAILING, FABRICATION, AND ERECTION OF ALL STRUCTURES SHALL CONFORM TO THE CODES LISTED
BELOW. (LATEST EDITIONS SHALL BE USED UNLESS SPECIFIED).
5.
ALL REINFORCING SHALL BE SUPPORTED IN FORMS, SPACED WITH NECESSARY ACCESSORIES AND SHALL BE
SECURELY WIRED TOGETHER, IN ACCORDANCE WITH ACI 318.
6.
MINIMUM CONCRETE COVER FOR THE REINFORCEMENT SHALL BE AS DETAILED ON THE DRAWINGS. WHERE
THE COVER IS NOT DIMENSIONED, USE PROVISIONS OF ACI 318.
7.
DEVELOPMENT OF REINFORCEMENT AND LAP SPLICES SHALL BE IN ACCORDANCE WITH ACI 318 ALL SPLICES
SHALL BE CLASS "B" TYPE.
8.
MECHANICAL SPLICES SHALL BE IN ACCORDANCE WITH ACI 318 AND DEVELOP AT LEAST 125 PERCENT OF
THE SPECIFIED YIELD STRESS OF THE BAR.
9.
ALL MAIN VERTICAL AND HORIZONTAL REINFORCING STEEL EXCLUDING TIES AND STIRRUPS, SHALL BE
MECHANICALLY SPLICED OR LAPPED PER SCHEDULE ON TYPICAL DETAILS SHEET.
ALL CONCRETE SHALL HAVE A MINIMUM DENSITY OF 150 PCF AND A MINIMUM COMPRESSIVE STRENGTH AT 28
DAYS AS FOLLOWS:
A. 300kg/cm2 FOUNDATION AND SLAB ON GRADE.
B. 250kg/cm2 SLAB ON COMPOSITE DECK.
C. 100kg/cm2 MUD SLAB.
2.
BEFORE PLACING CONCRETE, COORDINATE WITH MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTOR FOR
BLOCKOUTS AND EMBEDDED ITEMS NOT SHOWN ON STRUCTURAL DRAWINGS.
3.
EXPOSED EDGES OF CONCRETE ABOVE GRADE SHALL HAVE 20 MM x 45 DEGREE CHAMFERS, UNLESS NOTED
OTHERWISE (U.N.O.)
4.
ALL CONTROL JOINTS IN SLAB-ON-GRADE SHALL BE SAWN WITHIN 12 HOURS OF CONCRETE PLACEMENT
WITHOUT RAVELING THE JOINTS.
5.
ANCHOR RODS SHALL BE ASTM F1554 (Fy=2500 kg/cm2 (36 ksi)) RODS, U.N.O. ALL ANCHOR ROD PROJECTIONS
NOTED OR SHOWN ON THE DRAWINGS SHALL BE MEASURED FROM THE TOP OF THE ROUGH CONCRETE AND
NOT SET FROM THE GROUT.
INTERNATIONAL BUILDING CODE, IBC 2018 EDITION.
6.
BASE PLATES AND ANCHOR RODS BELOW GRADE SHALL BE COVERED WITH A MINIMUM OF 75MM OF CONCRETE.
3.
ASCE 7-16 "MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES".
7.
4.
ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS".
PROVIDE STANDARD HOOKS ON BARS TERMINATING AT A CONCRETE FACE UNLESS NOTED (E.G.: EDGES OF
OPENINGS, SLAB EDGES, EXPANSION JOINTS, ENDS OF BEAMS, AND AT TOP, BOTTOM, AND ENDS OF WALLS,
ETC.).
5.
ACI 318-14 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE".
8.
6.
AISC 360-16 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS".
7.
AISC 303-16 "CODE OF STANDARD PRACTICE FOR BUILDINGS AND BRIDGES".
ALL CONSTRUCTION JOINTS SHOWN ON DRAWINGS SHALL BE INCORPORATED INTO THE STRUCTURE, UNLESS
THEIR ELIMINATION IS APPROVED BY THE STRUCTURAL ENGINEER. ADDITIONAL CONSTRUCTION JOINTS,
REQUIRED TO FACILITATE CONSTRUCTION, SHALL BE LOCATED AT POINTS OF MINIMUM SHEAR, AND SHALL BE
DETAILED ON SHOP DRAWINGS. REINFORCEMENT SHALL PASS CONTINUOUSLY THROUGH THE JOINT.
8.
ANSI/AWS D1.1 "STRUCTURAL WELDING CODE - STEEL", D1.4 "STRUCTURAL WELDING CODE - REINFORCING
STEEL" AND D1.3 "STRUCTURAL WELDING CODE - SHEET STEEL".
NORMAS TECNICAS COMPLEMENTARIA ESTRUCTURALES DE LA LEY DE EDIFICACIONES DEL ESTADO
DE JALISCO.
SPECIAL INSPECTION
1.
SPECIAL INSPECTION SHALL BE IN ACCORDANCE WITH THE BUILDING CODE
2.
SPECIAL INSPECTION REPORT SHALL BE AS INDICATED ON THE TESTING, INSPECTION, OBSERVATION
PROGRAM APPROVED BY OWNER
3.
BUILDING CLASSIFICATION PER IBC-2018
1.
RISK CATEGORY II.
STRUCTURAL LOADS
1.
NO PROVISIONS HAVE BEEN MADE FOR FUTURE VERTICAL EXPANSION. FOUNDATIONS HAVE BEEN
DESIGNED FOR FUTURE HORIZONTAL EXPANSION TO THE WEST.
2.
GRAVITY LOADS:
DEAD LOAD
-SELF WEIGHT OF STRUCTURE AND ELEMENTS INCORPORATED INTO CONSTRUCTION DRAWINGS
-TYPICAL COLLATERAL LOAD (MECHANICAL,ELECTRICAL,PLUMBING):
15kg/m2
-FIRE PIPING:
5 kg/m2
LIVE LOADS
- OFFICE LIVE LOAD:
250kg/m2
- CORRIDOR LIVE LOAD:
400kg/m2
- STAIR LIVE LOAD:
500kg/m2
- LIGHT STORAGE LIVE LOAD:
625kg/m2
- HEAVY STORAGE LIVE LOAD:
1250kg/m2
- ROOF LIVE LOAD (REDUCIBLE PER ASCE 7-16):
100kg/m2
3.
WIND LOAD DESIGN PARAMETERS PER ASCE 7-16 (AND FM GLOBAL 1-28):
- BASIC WIND SPEED – 190 KM/H (115 MPH)
- EXPOSURE CATEGORY – C
4.
SEISMIC DESIGN PARAMETERS:
A. PROCEDURE OUTLINED IN IBC-2018 (ASCE 7-16) WITH THE FOLLOWING DESIGN PARAMETERS:
- RISK IMPORTANCE FACTOR : I=1.0
- SITE CLASS = C
- DESIGN SPECTRAL ACCELERATIONS PER SITE SPECIFIC SEISMIC STUDY:
- SDS =0.23G
- SEISMIC DESIGN CATEGORY: B
- SEISMIC FORCE RESISTING SYSTEMS:
"STEEL SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE" (R=3, Ω=3, Cd=3)
B. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
WELDED CONNECTIONS SHALL BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE." WELDING
ELECTRODES SHALL BE E70XX.
6.
SPLICING OF STEEL MEMBERS, UNLESS SHOWN ON DRAWINGS, IS PROHIBITED.
7.
NO CHANGE IN SIZE OR POSITION OF THE STRUCTURAL ELEMENTS SHALL BE MADE AND HOLES, SLOTS,
CUTS, ETC. ARE NOT PERMITTED THROUGH ANY MEMBER UNLESS THEY ARE DETAILED ON THE APPROVED
SHOP DRAWINGS.
8.
NO FINAL BOLTING OR WELDING SHALL BE MADE UNTIL THE STRUCTURE HAS BEEN PROPERLY ALIGNED.
9.
NO BEAM OR BRACE CONNECTION SHALL HAVE LESS THAN TWO (2) BOLTS OR AN EQUIVALENT WELD.
10.
CORROSION PROTECTION: PAINTING OF STRUCTURAL STEEL (OR GALVANIZING WHERE APPLICABLE) IS
REQUIRED FOR ANY EXPOSED STEEL.
11.
FOR CORROSION PROTECTION: SEE STRUCTURAL STEEL SPECIFICATION SECTION 051200.
12.
BOLTS IN BOLTED CONNECTIONS DESIGNATED AS PRETENSIONED JOINTS SHALL BE INSTALLED WITH
TENSION CONTROL BOLTS (ASTM F3125/F3125M).
13.
PRETENSIONED JOINTS ARE REQUIRED AT THE FOLLOWING LOCATIONS WHEN BOLTED CONNECTIONS ARE
INDICATED:
A. MOMENT FRAME CONNECTIONS
B. CONNECTIONS OF BEAMS BEARING ON COLUMN CAP PLATES
C. DRAG BEAM CONNECTIONS
D. HANGERS
E. CONNECTIONS OF BEAMS THAT ARE PART OF THE VERTICAL BRACING SYSTEM
F. ELEVATOR MACHINE BEAMS
G. SPECIAL CONNECTIONS AS INDICATED ON THE DRAWINGS
CONCRETE
1.
2.
9.
5.
COLD - FORMED STEEL FRAMING
1.
ASTM A653/ A653 M, GRADE 50 Fy= 3500 kg/cm2.
2.
COLD-FORMED METAL FRAMING SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH AISI'S "NORTH
AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS," 2010.
3.
FULL-HEIGHT DOUBLE STUDS SHALL BE PROVIDED AT THE ENDS OF PARTITIONS AND AT WALL OPENINGS UNLESS
NOTED OTHERWISE ON DRAWINGS.
4.
FULL-HEIGHT DOUBLE STUDS SHALL BE PROVIDED AT OTHER LOCATIONS INDICATED IN THE STRUCTURAL DRAWINGS.
A. WELD THE FLANGES OF DOUBLE STUDS TOGETHER FULL HEIGHT USING 50mm OF WELD AT 300mm C.C.
EACH SIDE.
5.
ANCHOR TRACKS OF INTERIOR STUD WALLS WITH LOW-VELOCITY (TYPE X-U) POWDER ACTUATED FASTENERS WITH A
MINIMUM SHANK DIAMETER OF 4mm, AND A MINIMUM PENETRATION OF 32mm. LOCATE ANCHORS 75mm FROM THE ENDS
OF PARTITIONS, AND AT 400mm C.C. (MAX.) THROUGHOUT FOR INTERIOR PARTITIONS UNLESS NOTED OTHERWISE
(U.N.O). REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS.
6.
PROVIDE VERTICAL DEFLECTION CLIPS/SLIP DEVICES AT TOP OF STUDS AS SHOWN ON DRAWINGS.
7.
PROVIDE STUD WALL BRIDGING ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
8.
SPLICES IN STUDS SHALL NOT BE PERMITTED. DO NOT CUT STUDS.
9.
AT LOCATIONS REQUIRING WELDING OF OR TO METAL STUDS, MINIMUM STUD THICKNESS SHALL BE 43 MIL.
10.
THE NOMINAL WELD FOR FILLET WELD OR FLARE GROOVE WELD SHALL BE AS FOLLOWS (UNLESS NOTED OTHERWISE):
STEEL THICKNESS (MILS)
WELD SIZE
43
1/16” (1.6 mm)
54
3/32” (2.4 mm)
68 AND LARGER
1/8” (3.2 mm)
11.
PROVIDE TRACK AT TOP AND BOTTOM OF STUD WALLS AND AT HEADERS AND SILLS FOR STUD WALLS, THICKNESS
OF TRACK TO MATCH THICKNESS OF STUD.
12.
TRACK THAT IS USED FOR JAMBS, HEADERS AND SILLS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE
MEMBER. NO SPLICES ARE ALLOWED.
THE FOLLOWING TYPES OF WORK REQUIRE SPECIAL INSPECTIONS: (REFER TO THE BUILDING CODE AND
SPECIFICATIONS FOR DETAILED INSPECTION REQUIREMENTS
A. PREPARED FILL AND BEARING CAPACITY FOR SHALLOW FOUNDATIONS
B. PLACEMENT OF CONCRETE
C. CAST-IN PLACE AND POST-INSTALLED ANCHORS IN CONCRETE
D. SPECIAL INSERTS, STUD RAILS, REBAR MECHANICAL CONNECTION, HEADED REBARS
E. REINFORCING STEEL
F. WELDING OF REINFORCING REBARS
G. AUTOMATIC AND END-WELDED STUDS
H. WELDING
I. STEEL FRAMING
www.vestalcorporation.com
THE STRUCTURE, INCLUDING THE FOLLOWING SYSTEMS BUT NOT LIMITED TO: STEEL MOMENT FRAMES,
STEEL BRACED FRAMES, CAST-IN-PLACE CONCRETE SLABS, AND STEEL ROOF DECK DIAPHRAGM, IS
DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. ALL TEMPORARY BRACING AND/OR SUPPORT THAT
MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR
SEQUENCES SHALL BE DESIGNED AND FURNISHED BY CONTRACTOR.
REFERENCES
PRINTED: 1/28/2022 14:04:28
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
ALL REINFORCING BARS SHALL BE DETAILED, FABRICATED, SUPPORTED AND PLACED IN ACCORDANCE WITH
ACI 315-99 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" AND CRSI "MANUAL OF STANDARD
PRACTICE" 2008.
NO CHANGE IN SIZE OR DIMENSION OF STRUCTURAL MEMBERS SHALL BE MADE WITHOUT THE WRITTEN
APPROVAL OF THE OWNER'S REPRESENTATIVE.
13.
1.
4.
IK
12.
BOLTED CONNECTIONS SHALL BE BEARING TYPE USING A325N BOLTS, UNLESS NOTED OTHERWISE.
OVERSIZED HOLES AND LONG-SLOTTED HOLES ARE NOT ALLOWED, UNLESS SHOWN ON THE DRAWINGS.
PK APROBO:
11.
4.
DIBUJO:
NO PIPES, DUCTS, CHASES ETC. SHALL BE PLACED IN STRUCTURAL BEAM AND COLUMN MEMBER NOR
SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS NOTED OTHERWISE. NOTIFY
STRUCTURAL ENGINEER WHEN DOCUMENTS BY OTHER DISCIPLINES SHOW OPENINGS, SLEEVES, POCKETS,
ETC. NOT INDICATED ON STRUCTURAL DRAWINGS, BUT ARE LOCATED IN STRUCTURAL MEMBERS.
CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR STRUCTURAL ENGINEER FOR INSTALLATION OF SUCH
PIPES, DUCTS, CHASES, ETC.
ALL REINFORCING STEEL, ANCHOR RODS, DOWELS, INSERTS, ETC. SHALL BE WELL SECURED IN PLACE AND
INSPECTED BY OWNER'S REPRESENTATIVE PRIOR TO PLACING CONCRETE.
T: 314.439.9900
F: 314.439.9906
10.
3.
21023-050000a-S002
DO NOT SCALE THESE DRAWINGS - USE DIMENSIONS
REINFORCING STEEL TO BE WELDED OR AS SPECIFICALLY NOTED SHALL BE ASTM A706 DEFORMED BARS.
1 : 10
9.
2.
ESCALA:
INFORM THE OWNER'S REPRESENTATIVE IN WRITING OF ANY DEVIATION FROM THE CONTRACT
DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY OF SUCH DEVIATION BY
THE OWNER'S REPRESENTATIVE REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC., UNLESS THE
CONTRACTOR HAS SPECIFICALLY INFORMED THE OWNER'S REPRESENTATIVE OF SUCH DEVIATION AT THE
TIME OF SUBMISSION, AND THE OWNER'S REPRESENTATIVE HAS GIVEN WRITTEN APPROVAL TO THE
SPECIFIC DEVIATION.
UNLESS NOTED OTHERWISE, THE MINIMUM PLATE THICKNESS SHALL BE 10MM; MINIMUM BOLT DIAMETER
SHALL BE 19MM; MINIMUM WELD SHALL BE 5MM.
mm
8.
COORDINATE THE LOCATIONS AND SIZES OF ALL OPENINGS IN CAST-IN-PLACE WALLS AND FLOORS, AND
LOCATIONS OF COMPONENTS REQUIRED TO BE EMBEDDED IN THE CONCRETE, WITH THE ARCHITECTURAL
DRAWINGS AND PLUMBING, MECHANICAL, AND ELECTRICAL REQUIREMENTS.
REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A-615, GR 60, U.N.O.
DIBUJO NO:
7.
DETAILS ENTITLED OR NOTED AS TYPICAL SHALL APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR
REFERENCED, BUT WHERE THE NATURE OF THE CONSTRUCTION REQUIRES THEIR USE.
1.
COTAS:
6.
3.
REINFORCEMENT
CORPORATION
OPENINGS FOR CONDUIT, PIPE BANKS, ETC., NOT SHOWN ON STRUCTURAL DRAWINGS SHALL BE
APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. ADDITIONAL STRUCTURAL
REINFORCEMENT AND CLOSURES FOR FLOOR AND WALL SHALL BE PROVIDED.
ALL STRUCTURAL STEEL SHALL BE DETAILED FABRICATED AND ERECTED IN ACCORDANCE WITH AISC "CODE
OF STANDARD PRACTICE".
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
5.
2.
GENERAL NOTES
(NOTAS GENERALES)
VERIFY THE COORDINATION OF ALL TRADES AND REPORT ANY CONFLICTS IMMEDIATELY TO THE OWNER'S
REPRESENTATIVE.
26-JAN-2022
4.
0
EXCAVATIONS SHALL BE KEPT FREE OF LOOSE MATERIAL AND STANDING WATER.
IFC (REVIEW)
3.
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
SPECIFIC DETAILS AND NOTES TAKE PRECEDENCE OVER STANDARD DETAILS AND NOTES. WHERE
CONFLICTS EXIST BETWEEN THE DRAWINGS, THE SPECIFICATIONS, AND THE GENERAL STRUCTURAL
NOTES, THE STRICTEST PROVISION SHALL GOVERN.
A992 (Fy=3500 KG/CM2)
A36 (Fy=2500 KG/CM2)
A36 (Fy=2500 KG/CM2)
A53 GRB (Fy=2450 KG/CM2)
A500 GRB (Fy=3200 KG/CM2)
A500 GRB (Fy=2950 KG/CM2)
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
3.
A. ALL W AND WT SHAPES
B. ALL ANGLE, CHANNEL
C. ALL BASE PLATES, CONN. PLATES
D. STRUCTURAL PIPE
E. STRUCTURAL TUBE
F. HSS ROUND SHAPE
TITULO DEL PLANO:
OWNERS'S GEOTECHNICAL REPRESENTATIVE SHALL CERTIFY THE BEARING MEDIUM PRIOR TO
CONCRETE PLACEMENT.
FECHA / DATE
2.
REVISIONES / REVISION
VERIFY ALL DIMENSIONS BEFORE STARTING WORK AND NOTIFY THE OWNER'S REPRESENTATIVE
IMMEDIATELY OF ANY DISCREPANCIES FOUND.
STEEL SHALL CONFORM TO THE FOLLOWING GRADES:
FASE DISEÑO / DESIGN PHASE
2.
1.
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
THE FOUNDATION HAS BEEN DESIGNED IN ACCORDANCE WITH GEOTECHNICAL REPORT BY LAINCO
LABORATORIOS DATED TITLED "REPORT OF GEOTECHNICAL RESEARCH" DATED OCTOBER 15TH, 2021.
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
1.
REVISIONES / REVISIONS
IN MOST CASES THE CRITERIA FOR THE STRUCTURE IS ESTABLISHED ON THE DRAWINGS AND IN THE
SPECIFICATIONS. WHERE IT IS NOT, THESE NOTES SHALL GOVERN.
CLIENTE / CLIENT
1.
STRUCTURAL STEEL
FIRMA DE DISEÑO / DESIGN FIRM
FOUNDATION EXCAVATION AND BACKFILL
GENERAL NOTES
DIAGEO - EL CHARCON - ELEVATE II PROJECT
STRUCTURAL GENERAL NOTES
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
.
10.
TODO EL ACERO ESTRUCTURAL EXPUESTO DEBERA CONTAR CON UN ANTICORROSIVO Y PINTURA,
EXCEPTO EN AQUELLOS CASOS DONDE LA ESTRUCTURA SEA GALVANIZADA.
A.
B.
C.
9.
NO SE DEBERAN TOMAR MEDIDAS A ESCALA, LAS COTAS RIGEN AL DIBUJO.
10.
NO SE PERMITE INSTALAR TUBERIAS, DUCTOS, EN LAS COLUMNAS O VIGAS ESTRUCTURALES , NI
REALIZAR HUECOS O CORTAR NINGUNO DE LOS ELEMENTOS ESTRUCTURALES PARA TUBERIAS O DUCTOS A
EXCEPCION DONDE SE INDIQUE. SE DEBERA NOTIFICAL AL INGENIERO EN ESTRUCTURAS CUANDO LOS
DOCUMENTOS DE OTRAS DISCIPLINAS INDIQUEN EN LOS ELEMENTOS ESTRUCTURALES HUECOS, CAMISAS
PARA PASO U OQUEDADES NO MOSTRADOS EN LOS PLANOS ESTRUCTURALES. EL CONTRATISTA DEBERA
CONTAR CON LA APROBACION DEL INGENIERO EN ESTRUCTURAS PREVIO A CUALQUIER INSTALACION DE
TUBERIAS, DUCTOS EN CUALQUIER ELEMENTO ESTRUCTURAL.
300kg/cm2 - CIMENTACIÓN LOSAS DE PISO
250kg/cm2 - LOSAS DE ENTREPISO (EN LOSACERO)
100kg/cm2 - HORMIGON
11. PARA PROTECCION POR CORROSION: VER ESPECIFICACION DE ACERO ESTRUCTURAL SECCION 051200
2.
ANTES DE COLOCAR EL CONCRETO SE DEBERA DE COORDINAR CON LAS DISCIPLINAS MECÁNICA,
ELECTRICA E INSTALACIONES HIDRAULICAS Y SANITARIAS, POR CUALQUIER HUECO O ELEMENTOS
EMBEBIDOS NECESARIOS Y QUE NO SE MUESTRE EN LOS PLANOS ESTRUCTURALES.
3.
LOS BORDES EXPUESTOS DE CONCRETO POR ENCIMA DEL NIVEL DE PISO TERMINADO TENDRÁN UN
CHAFLAN DE 20 MM, A MENOS QUE SE INDIQUE LO CONTRARIO.
11.
CUALQUIER CAMBIO EN TAMAÑO O DIMENSION DE LOS ELEMENTOS ESTRUCTURALES DEBERA DE CONTAR
CON EL CONSENTIMIENTO POR ESCRITO DEL REPRESENTANTE DEL PROPIETARIO.
4.
TODAS LAS JUNTAS DE CONTRACCION EN LAS LOSA DE PISOS SE DEBERAN DE CORTAR ANTES DE 12
HORAS DE TERMINADO EL COLOCADO, PERO SIN EL DESPORTILLAMIENTO DE LAS JUNTAS.
12.
LA ESTRUCTURA INCLUYE LOS SIGUIENTES SISTEMAS.(DE FORMA NO EXCLUYENTE): ESTRUCTURA
METALICA A BASE DE MARCOS RIGIDOS, MARCOS CONTRAVENDEADOS, LOSAS DE CONCRETO COLADAS
EN SITIO, Y CUBIERTAS METALICAS, LAS CUALES SE HAN DISEÑADO PARA TRABAJAR COMO UNA SOLA
UNIDAD UNA VEZ CONCLUIDOS LOS TRABAJOS. CUALQUIER ARRIOSTRAMIENTO Y/O SOPORTE TEMPORAL
QUE SE REQUIERA COMO EL RESULTADO DE METODOS Y/O SECUENCIAS DE CONSTRUCCIÓN DEL
CONTRATISTA SERÁN DISEÑADAS Y SUMINISTRADAS POR EL CONTRATISTA .
5.
LAS ANCLAS SERÁN ASTM F1554 (Fy = 2500KG/CM2 (36 ksi)) BARRAS, EXCEPTO SE INDIQUE OTRA COSA.
TODAS LAS PROYECCIONES DEL ANCLAJE INDICADAS EN LOS PLANOS SE MEDIRÁN DEL TOPE DEL
CONCRETO, Y NO DEL GROUT.
6.
LAS PLACAS BASE Y ANCLAS QUE SE ENCUENTREN POR DEBAJO DEL NIVEL DE PISO TERMINADO DEBERAN
DE QUEDAR EMBEBIDAS DE CONCRETO CON UN MÍNIMO DE 75MM.
TODO EL MATERIAL DE RELLENO QUE PROVENGA FUERA DE LA OBRA DEBE PROVENIR DE UN SITIO CON
LICENCIA, QUE CUMPLA CON LAS ESPECIFICACIONES Y APROBADO POR EL PROPIETARIO.
7.
A MENOS DE QUE SE INDIQUE OTRA COSA EN PLANOS; EN LOS REMATES EN HUECOS, EN LAS ORILLAS DE
LAS LOSAS, EN LA TERMINACION DE LOS MUROS, EN HUECOS, EN LOS EXTRMEOS DE LAS VIGAS Y
COLUMNAS, TODAS LAS VARILLAS SE DEBERAN DE ANCLAR POR MEDIO DE GANCHOS ESTANDAR EN SUS
EXTREMOS.
13.
14.
TODO EL MATERIAL DE LA EXCAVACIÓN SERA EXAMINADO POR EL PROPIETARIO ANTES DE RETIRARLO
DEL SITIO
REFERENCIAS
1.
TODAS LAS ESTRUCTURAS SE DETALLARAN, FABRICARAN Y MONTARAN CONFORME A LA ULTIMA REVISION
DE LOS CODIGOS ENLISTADOS A CONTINUACION, A MENOS DE QUE SE ESPECIFIQUE OTRA COSA EN
PLANOS.
2.
CODIGO INTERNACIONAL DE CONSTRUCCION. IBC EDICION 2018.
8.
TODAS LAS JUNTAS DE CONSTRUCCION SE DEBERAN DE REALIZAR COMO SE INDICA EN LOS PLANOS, A
MENOS DE QUE SU ELIMINACION SEA APROBADA POR EL INGENIERO ESTRUCTURAL. SE PODRAN
ADICIONAR JUNTAS DE CONSTRUCCION DURANTE EL PROCESO DE LA OBRA, SIN EMBARGO ESTAS SE
DEBERÁN DE LOCALIZAR EN LOS PUNTOS DONDE SE TENGA EL CORTANTE MÍNIMO. EN ESTOS CASOS SE
DEBEN DE DETALLAR E INTEGRAR EN LOS PLANOS, EL REFUERZO DEBERÁ SER CONTINUO A TRAVÉS DE LA
JUNTA
PRINTED: 1/28/2022 14:04:29
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
INSPECCIONES ESPECIALES
3.
ASCE 7-16 “CARGAS DE DISEÑO MÍNIMAS PARA EDIFICIOS Y OTRAS CONSTRUCCIONES”.
4.
ACI 301 “ESPECIFICACIONES PARA CONCRETO ESTRUCTURAL DE EDIFICIOS’’.
5.
ACI 318-14 "REQUISITOS DE CONSTRUCCIÓN DE CONCRETO ARMADO" .
6.
AISC 360-16 “ESPECIFICACIONES PARA EDIFICIOS DE ACERO ESTRUCTURAL”.
7.
AISC 303-16 “CÓDIGO DE PRÁCTICAS ESTANDARES PARA EDIFICIOS Y PUENTES”.
8.
ANSI / AWS D1.1 "CÓDIGO DE SOLDADURA ESTRUCTURAL- ACERO", AWS D1.4 CODIGO DE SOLDADURA
ESTRUCTURAL - ACERO DE REFUERZO", Y D1.3 "CÓDIGO DE SOLDADURA ESTRUCTURAL- ACERO EN PLACA”.
9.
NORMAS TECNICAS COMPLEMENTARIA ESTRUCTURALES DE LA LEY DE EDIFICACIONES DEL ESTADO
DE JALISCO.
CLASIFICACIÓN DEL EDIFICIO DE ACUERDO A LA IBC-2018
1.
1.
LAS INSPECCIONES ESPECIALES DEBEN SER DE ACUERDO AL CÓDIGO O REGLAMENTOS DE
CONSTRUCCION.
2.
LOS INFORMES DE LAS INSPECCIONES ESPECIALES DEBEN SER SEGÚN LO ESTABLECIDO EN EL PROGRAMA
DE PRUEBAS INSPECCIONES/OBSERVACIÓN APROBADO POR EL PROPIETARIO O SU REPRESENTANTE.
3.
LOS SIGUIENTES TRABAJOS REQUIEREN DE UNA INSPECCION DETALLADA Y ESTARA CONFORME A
CODIGOS, NORMAS Y ESPECIFICACIONES TÉCNICAS.
A.
B.
C.
D.
E.
F.
G.
H.
I.
MATERIAL DE RELLENO
COLADO DE CONCRETO.
ANCLAS EN CONCRETO FRESCO Y ANCLAS INSTALADAS POSTERIORES AL COLADO.
INSERTOS ESPECIALES, PERNOS DE ANCLAJE, EMPALME MECÁNICO EN EL ACERO DE REFUERZO,
ANCLAJES MECANICOS EN EXTREMO DEL ACERO DE REFUERZO.
ACERO DE REFUERZO EN GENERAL.
SOLDADURA DE BARRAS DE REFUERZO.
PERNOS SOLDADOS AUTOMÁTICAMENTE Y LOS PERNOS CON SOLDADURA EN EL EXTREMO.
SOLDADURA
MARCOS ESTRUCTURALES ACERO
12.
TORNILLOS EN CONEXIONES ATORNILLADAS, DESIGNADAS COMO JUNTAS PRETENSIONADAS, DEBERAN
SER INSTALADAS CON TORNILLOS DE TENSION CONTROLADA (ASTM F3125/F3125M)
13. JUNTAS PRE-TENSIONADAS SERÁN REQUERIDAS EN LAS SIGUIENTES UBICACIONES DONDE LAS
CONEXIONES ATORNILLADAS SEAN INDICADAS:
A. MOMENTO EN CONEXIONES DE MARCO
B. CONEXIONES EN TRABES DE SOPORTE EN PLACAS SOBRE COLUMNAS
C. CONEXIONES EN VIGAS DE ARRASTRE
D. GANCHOS
E. CONEXIONES DE TRABES QUE SON PARTE DE UN SISTEMA VERTICAL DE CONTRAVENTEOS
F. TRABES DE MAQUINARIA DE ELEVADORES
G. CONEXIONES ESPECIALES TAL COMO SE INDICA EN EL PLANO
MARCOS DE ACERO FORMADO EN FRÍO
1.
ASTM A653/653 M, GRADO 50, Fy= 3500 kg/cm2
2.
LOS MARCOS DE PERFILES ROLADOS EN FRIO DEBERAN DE DISEÑARSE, FABRICARSE Y
MONTARSE DE ACUERDO A LO SIGUIENTE: ESPECIFICACION NORTE AMERICANA PARA EL DISEÑO DE
PERFILES ESTRUCTURALES ROLADOS EN FRIO. AISI 2007
3.
EN LOS EXTREMOS DE LAS DIVISIONES Y EN LAS ABERTURAS PARA MUROS SE DEBERA DE COLOCAR
POSTES DOBLES EN TODA LA ALTURA, EXCEPTO SE INDIQUE OTRA COSA EN LOS PLANOS
4.
SE COLOCARAN POSTES DOBLES EN AQUELLOS LUGARES QUE INDIQUEN LOS PLANOS ESTRUCTURALES
A. LOS POSTES DOBLES SE SOLDARAN EN LOS PATINES MEDIANTE SOLDADURA DE 50 MM SEPARADAS A
CADA 300 mm, A CADA LADO DE LOS POSTES.
5.
LOS PERFILES HORIZONTALES DE DESPLANTE DONDE SE SOPORTARAN LOS POSTES EN PAREDES
INTERIORES DEBERA SER MEDIANTE ANCLAJES DE BAJA VELOCIDAD (TIPO X-U) DE DIAMETRO MINIMO DE
0.157 PULGADAS (4.0 mm) Y CON UNA PENETRACION MINIMA DE 1-1/4 PULGADA (32 mm). LA LOCALIZACION DE
LOS ANCLAJES SERA DE 3”(76mm) DESDE LOS EXTREMOS DE LAS DIVISIONES Y POSTERIOMENTE DEBERAN
DE QUEDAR ESPACIADOS A CADA 16 PULGADAS ( 400mm) COMO MAXIMO EN TODAS LAS DIVISIONES
INTERIORES, EXCEPTO SE INDIQUE OTRA COSA (U.N.O.). VER PLANOS ARQUITECTONICOS PARA DETALLES.
6.
INSTALAR ANGULOS DE LAMINA (CLIP/SLIP) QUE PERMITAN EL DESPLAZAMIENTO VERTICAL EN EL EXTREMO
SUPERIOR DE LOS POSTES COMO SE INDICA EN LOS DIBUJOS.
7.
INSTALAR PERFILES HORIZONTALES PARA ARRIOSTRAR LOS POSTES EN PAREDES CONFORME A LAS
RECOMENDACIONES DE LOS FABRICANTES.
8.
NO SE PERMITE EL EMPALME DE LOS POSTE. NO SE DEBRAN CORTAR.
9.
EN LOS LUGARES QUE REQUIERAN SOLDAR A LOS POSTES O DESDE ELLOS, EL ESPESOR MINIMO DEBERA DE
SER DE 43 MIL
10.
LA SOLDADURA DE FILETE NOMINAL O SOLDADURA DE RANURA DEBERA SER COMO SE INDICA A
CONTINUACION (EXCEPTO SE INDIQUE OTRA COSA)
ESPESOR DE ACERO (MILS) TAMAÑO FILETE
CATEGORÍA DE RIESGO II.
43
54
68 Y MAYORES
CARGAS ESTRUCTURALES
1.
2.
NO SE HA CONSIDERADO NINGUN ELEMENTO ADICIONAL PARA CUALQUIER EXPANSION VERTICAL. LAS CIMENTACIONES
HAN SIDO DISEÑADAS PARA UNA FUTURA EXPANSION HORIZONTAL HACIA EL OESTE.
CARGAS GRAVITACIONALES:
CARGA MUERTA
- PESO PROPIO DE LA ESTROCTURA Y ELEMENTOS INCORPORADOS EN LOS PLANOS DE CONSTRUCCION
- CARGA MUERTA COLATERAL TÍPICA (MECÁNICO, ELÉCTRICO, PLOMERÍA):
15 KG/M2
- TUBERÍA CONTRA INCENDIO:
5 KG/M2
CARGA VIVA
- CARGA VIVA EN OFICINA:
- CARGA VIVA EN CORREDOR:
- CARGA VIVA EN ESCALERAS:
- CARGA VIVA PARA ALMACENAMENTO LIGERO:
- CARGA VIVA PARA ALMACENAMENTO PESADO:
- CARGA VIVA EN TECHOS (REDUCIBLE POR ASCE 7-16):
250 KG/M2
400 KG/M2
500 KG/M2
625 KG/M2
1250 KG/M2
100 KG/M2
3.
LAS CARGAS DE VIENTO PARA DISEÑO SON CONFORME AL ASCE 7-16 (Y LAS RECOMENDACIONES DE FM GLOBAL 1-28):
- VELOCIDAD BASICA DE VIENTO – 190 KM/H (115 MPH)
- CATEGORIA DE EXPOSICION – C
4.
PARAMETROS DE DISEÑO SISMICO:
A. EL PROCEDIMIENTO ES COMO SE INDICA EN IBC-2018 (ASCE 7-16) CON LOS SIGUIENTES
PARAMETROS DE DISEÑ0:
- FACTOR DE IMPORTANCIA CONFORME A EL RIESGO: I=1.0
- CLASIFICACION DE SITIO-C
- ACELERACIONES ESPECTRALES DE DISEÑO POR ESTUDIO SISMICO ESPECIFICO DE SITIO:
- SDS = 0.23G
- CATEGORIAS DE DISENO SISMICO: B
- PARAMETROS SISMICOS PARA OBTENCION DE FUERZAS EN EL SISTEMA:
- "NO ESPECÍFICAMENTE DETALLADO DE RESISTENCIA SÍSMICA" (R=3, Ω=3, Cd=3)
B. EL PROCEDIMIENTO DE ANALISIS EMPLEADO ES: FUERZAS EQUIVALENTES LATERALES
EXCAVACIÓN DE LA CIMENTACIÓN Y RELLENO
1.
LAS CIMENTACIÓNES FUERON DISENADAS DE ACUERDO CON EL REPORTE GEOTECNICO POR LAINCO
LABORATORIOS CON FECHA REPORTE INVESTIGACION GEOTECNICA DE FECHA 15 OCTUBRE 2021.
2.
EL REPRESENTANTE DE MECANICA DE SUELOS DEL DUEÑO DEBERÁ VERIFICAR LAS CARACTERISTICAS
DEL SUELO PREVIO A LA COLOCACIÓN DEL CONCRETO.
3.
LAS EXCAVACIONES DEBERÁN MANTENERSE LIBRES DE MATERIAL SUELTO Y AGUA ESTANCADA..
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
11.
SUMINISTRAR UNA GUIA EN LA PARTE SUPERIOR E INFERIOR DE LOS POSTES, EN LOS CABECEROS DE PUERTAS,
VENTANAS Y HUECOS, EN LA PARTE INFERIOR DE LAS VENTANAS O HUECO. TODASL LAS GUIAS A INSTALAR
SEGÚN SE REQUIERA DEBERAN DE SER DEL MISMO ESPESOR DE LOS POSTES.
12.
LAS GUIAS QUE SE USEN EN LAS CHAMBRANAS, EN LA PARTE SUPERIOR DE HUECOS, PUERTAS, Y VENTANAS ASI
COMO LAS NECESARIAS EN LA PARTE INFERIOR DE HUECOS Y/O VENTANAS DEBERAN SER CONTINUAS NO SE
PERMITE LOS EMPALMES
www.vestalcorporation.com
TODAS LAS CONEXIONES ATRONILLADAS EN VIGAS O CONTRAVENTEOS DEBERAN DE CONTAR CON DOS
TORNILLOS MINIMO O SU EQUIVALENTE EN SOLDADURA.
TODO EL CONCRETO TENDRÁ UNA DENSIDAD MÍNIMA DE 2400 KG/M3 Y UNA RESISTENCIA MÍNIMA A LA
COMPRESIÓN A LOS 28 DÍAS COMO SE INDICA A CONTINUACION:
IK
1.
PK APROBO:
9.
CONCRETO
DIBUJO:
NO SE DEBERAN APRETAR LOS TORNILOS COMPLETAMENTE O REALIZAR LAS SOLDADURAS FINALES,
HASTA QUE LA ESTRUCTURA HAYA SIDO COMPLETAMENTE ALINEADA.
T: 314.439.9900
F: 314.439.9906
8.
21023-050000a-S003
NO DEBERAN REALIZARSE CAMBIOS EN TAMAÑO O POSICION DE LOS ELEMENTOS ESTRUCTURALES,
ASI COMO TAMPOCO REALIZAR PERFORACIONES, RANURAS, CORTES, ETC., A LOS MISMOS.
1 : 10
7.
TODO EL ACERO DE REFUERZO PRINCIPAL YA SEA VERTICAL Y HORIZONTAL CON EXCEPCIÓN DE AMARRES Y
ESTRIBOS, DEBERAN ESTAR MECÁNICAMENTE EMPALMADOS O UNIDOS DE ACUERDO A LO ESPECIFICADO
CONFORME AL PLANO DE DETALLES TIPICOS.
ESCALA:
9.
mm
NO SE PERMITE EL EMPALME DE LOS ELEMENTOS DE ACERO, A MENOS QUE SE INDIQUE EN LOS PLANOS
DIBUJO NO:
6.
COTAS:
LOS EMPALMES MECÁNICOS DEBEN ESTAR DE ACUERDO CON ACI 318 Y CAPACES DE DESARROLLAR POR LO
MENOS EL 125 POR CIENTO DEL ESFUERZO DE FLUENCIA ESPECÍFICADO PARA LA BARRA.
CORPORATION
8.
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
LAS CONEXIONES SOLDADAS DEBEN ESTAR DE ACUERDO CON AWS D1.1 "CÓDIGO DE SOLDADURA
ESTRUCTURAL." ELECTRODOS DE SOLDADURA SERÁN E70XX.
7.
GENERAL NOTES
(NOTAS GENERALES)
5.
EL RECUBRIMIENTO MÍNIMO DE CONCRETO SOBRE EL REFUERZO SERÁ DETALLADO EN LOS PLANOS. DONDE
EL RECUBRIMIENTO NO ESTE DIMENSIONADO, UTILIZAR LAS DISPOSICIONES DE LA ACI 318.
26-JAN-2022
LA LONGITUD DE DESARROLLO DEL ACERO DE REFUERZO Y EL TRASLAPE DE LAS VARILLAS SE HARÁN DE
ACUERDO CON ACI 318 TODOS LOS TRASLAPES SERÁN CLASE TIPO "B". EXCEPTO SE INDIQUE OTRA COSA.
6.
0
TODAS LAS CONEXIONES ATORNILLADAS DEBERAN UTILIZAR TORNILLOS A325N, A MENOS QUE SE
INDIQUE LO CONTRARIO. AGUJEROS GRANDES Y AGUJEROS SOBREDIMENSIONADOS NO ESTÁN
PERMITIDOS, A MENOS QUE SE INDIQUE EN LOS PLANOS.
TODO EL ACERO DE REFUERZO DEBERÁ ESTAR APOYADO SOBRE SILLETAS Y ESPACIADO CON LOS ACCESORIOS
NECESARIOS Y DEBERÁN ESTAR SÓLIDAMENTE AMARRADOS ENTRE SÍ, DE CONFORMIDAD CON ACI 318.
IFC (REVIEW)
SE DEBERA INFORMAR POR ESCRITO AL REPRESENTANTE DEL PROPIETARIO DE CUALQUIER DESVIACIÓN A
LOS DOCUMENTOS DEL CONTRATO. CUALQUIER DESVIACION AL PROYECTO EN LOS PLANOS DE TALLER Y
DIBUJOS DE CONSTRUCCION SERA RESPONSABILIDAD DEL CONTRATISTA, A MENOS DE QUE EXISTA
DOCUMENTO ESCRITO DONDE EL REPRESENTANTE DEL PROPIETARIO APRUEBE Y HAYA DADO SU
CONSENTIMIENTO PARA CUALQUIER DESVIACION ESPECIFICA O CAMBIO DE PROYECTO.
4.
5.
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
8.
PREVIO AL COLADO DEL CONCRETO SE DEBERA DE UBICAR Y DIMENSIONAR EL TAMAÑO DE LAS HUECOS,
ELEMENTOS EMBEBIDOS NECESARIOS EN MUROS Y PISOS DE CADA UNA DE LAS DISCIPLINAS,Y QUE SE
INDIQUEN EN LOS PLANOS: ARQUITECTÓNICOS, DE INSTALACIONES, MECANICOS Y ELECTRICOS,
RESPETANDO DIMESIONES Y DETALLES. MOSTRADOS.
A MENOS DE QUE SE ESPECIFIQUE OTRA COSA EN PLANOS, EL ESPESOR MINIMO DE LAS PLACAS
DEBERA SER DE 10MM; EN ANCLAS EL DIAMETRO MINIMO SERA DE 19MM; EL TAMAÑO MÍNIMO DE
SOLDADURA SERÁ DE 5MM.
TODO REFUERZO SERA DETALLADO, FABRICADO Y COLOCADO, CONFORME AL ACI 315-99 " DETALLES TIPICOS
Y HABILITADO DEL REFUERZO EN EL CONCRETO” Y CONFORME AL MANUAL DE PRACTICAS ESTANDARES DEL
CRSI' DE 2008.
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
7.
LOS DETALLES MARCADOS COMO TIPICOS SE PODRAN USAR NO SOLO DONDE ESTA ESPECIFICADO O
REFERENCIADO, SINO TAMBIEN EN DONDE SEAN SEMEJANTES LAS CONDICIONES DEL PROYECTO Y NO
ESTEN MARCADOS COMO TAL.
3.
4.
TITULO DEL PLANO:
6.
LOS HUECOS PARA TUBERÍAS, BANCOS DE DUCTOS, ETC., QUE NO ESTEN INDICADOS EN LOS PLANOS
ESTRUCTURALES DEBERÁN SER PRESENTADOS Y APROBADAS POR EL REPRESENTANTE DEL
PROPIETARIO. PREVIO A LA INSTALACIÓN SE DEBERA DE INCLUIR LOS DETALLES DE REFUERZOS
ESTRUCTURALES NECESARIOS, ASI COMO EL SELLADO EN PISO O MUROS.
TODO EL ACERO ESTRUCTURAL DEBERA SER DETALLADO FABRICADO Y CONSTRUIDO SEGUN AISC
“CÓDIGO DE PRÁCTICA ESTÁNDAR”.
TODO EL ACERO DE REFUERZO, ANCLAS, PASADORES, INSERTOS, ETC. DEBERÁN ESTAR BIEN SUJETOS
EN SU LUGAR Y REVISADOS POR EL REPRESENTANTE DEL PROPIETARIO ANTES DE VACIAR EL CONCRETO.
FECHA / DATE
5.
EL PROYECTO SE DEBERA DE COORDINAR CON TODAS LAS AREAS Y CUALQUIER CONFLICTO ENCONTRADO
SE REPORTARA INMEDIATAMENTE AL REPRESENTANTE DEL PROPIETARIO.
2.
3.
REVISIONES / REVISION
4.
DETALLES ESPECIFICOS Y NOTAS, PREVALECERAN SOBRE LOS DETALLES TIPICOS, CUANDO EXISTAN
DISCREPANCIA ENTRE LOS PLANOS, LAS ESPECIFICACIONES Y LAS NOTAS GENERALES DE LA
ESTRUCTURA, LAS PREVISIONES MAS ESTRICTAS REGIRAN AL PROYECTO.
TODO EL ACERO DE REFUERZO QUE VAYA A SER SOLDADO O EL QUE ESTÉ ESPECÍFICAMENTE
INDICADO, DEBERÁ SER ACERO CORRUGADO ASTM A706
FASE DISEÑO / DESIGN PHASE
3.
2.
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
PREVIO AL INICIO LOS TRABAJOS SE DEBERAN DE VERIFICAR TODAS LAS DIMENSIONES Y CUALQUIER
DISCREPANCIA ENCONTRADA SE DEBERA DE NOTIFICAR AL REPRESENTANTE DEL PROPIETARIO
INMEDIATAMENTE.
TODO EL ACERO ESTRUCTURAL SERA CONFORME A LOS SIGUIENTES GRADOS:
A.PERFILES W Y WT SERAN A992 (Fy=3500 KG/CM2)
B.ANGULOS, Y CANALES
A36 (Fy=2500 KG/CM2)
C.PLACAS BASE Y DE CONEXION
A36 (Fy=2500 KG/CM2)
D.TUBERIA ESTRUCTURAL
A53 GRB (Fy=2450 KG/CM2)
E.PERFILES HUECOS CUADRADOS O RECTANGULARES
A500 GRB (Fy=3200 KG/CM2)
F. PERFIL TUBULAR OC
A500 Grado B (Fy = 2950 kg/cm2)
EL ACERO DE REFUERZO DEBERA SERA MEDIANTE VARILLAS CORRUGADAS CONFORME A LA NORMA
ASTM A-615, GR 60, A MENOS DE QUE SE INDIQUE OTRA COSA
CLIENTE / CLIENT
2.
ACERO ESTRUCTURAL
1.
1.
FIRMA DE DISEÑO / DESIGN FIRM
EL CRITERIO PARA LAS ESTRUCTURAS ESTA ESTABLECIDO EN LOS DIBUJOS Y EN LAS ESPECIFICACIONES,
EN LOS CASOS QUE NO ESTE INDICADO EN LOS DOCUMENTOS ANTERIORES, ESTAS NOTAS SON LAS QUE
REGIRAN AL PROYECTO.
DIAGEO - EL CHARCON - ELEVATE II PROJECT
1.
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
ACERO DE REFUERZO
NOTAS GENERALES
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
REVISIONES / REVISIONS
NOTAS ESTRUCTURALES GENERALES
.
3
..............................
4
..............................
ABBREVIATION LEGEND (LEYENDA DE ABREVIACIONES):
5
..............................
Fxxx - CONCRETE FOOTING (ZAPATA DE CONCRETO)
6
..............................
7
..............................
8
..............................
9
..............................
CCxxx - CONCRETE COLUMN (COLUMNA DE CONCRETO)
7072
500
SOGxxx - CONCRETE MAT SLAB (LOSA DE CIMENTACIÓN DE CONCRETO)
8
Px - CONCRETE PILASTER (DADO DE CONCRETO)
S300
CWxx - CONCRETE WALL (MURO DE CONCRETO)
1200
5
S601
S601
OPP.
1
EQ MSxx- EQUIPMENT MAT SLAB (LOSA DE CIMENTACIÓN PARA EQUIPO)
S601
U.N.O. - UNLESS NOTED OTHERWISE (A MENOS QUE SE INDIQUE LO CONTRARIO)
MAT1000
TYP. - TYPICAL (TIPO)
4
S601
S601
M-5
P2-M
F4.0
CW300
CF500
S200
4
S601
S601
PROCESS DRAIN. REFER
TO PLUMBING
DRAWINGS FOR EXACT
LOCATION.
8870
M-2
S300
P2-M
F4.0
OPP.
1
1
S601
S601
6
6
6
S601
S601
S601
S601
CF500
6
CW300
CF500
CW300
4
S501
CW300
P2-M
F3.0
P2-M
F3.0
CW300
CW300
P2-M
F3.0 CW300
600
P2-M
F3.0
CF500
N 2273653.911
E 753556.219
CF500
CF500
5
1
S601
S300
2
CF500
7072
7072
2
5
S300
S601
7072
6.
FOR ANCHOR SCHEDULE AND DETAILS S601
7.
REINFORCEMNT PLACEMENT AND CONSTRUCTION SEQUENCING MUST BE COORDINATED
WITH THE AGAVE BUILDING FOUNDATIONS FOR ALL PILASTERS ALONG GRID M-7.
1.
NIVEL DE PISO TERMINADO SOBRE EL NIVEL DEL MAR = 1599.600, TIPO (A MENOS QUE SE INDIQUE LO
CONTRARIO). VER PLANO.
2.
NIVEL TOPE DE PILASTRA DEL PERÍMETRO ES IGUAL AL NIVEL DE PISO TERMINADO
3.
NIVEL TOPE DE ZAPATA SOBRE EL NIVEL DEL MAR (A MENOS QUE SE INDIQUE LO CONTRARIO) =
VARIABLE - VER PLANO.
4.
PARA NOTAS GENERALES - VER PLANO S003
5.
PARA TABLAS - VER PLANO S600
6.
PARA DETALLES Y TABLA DE ANCLAJES S601
7.
LA COLOCACIÓN DEL REFUERZO Y LA SECUENCOA DE CONSTRUCCIÓN DEBEN COORDINARSE CON LAS
CIMENTACIONES DEL EDIFICIO DE AGAVE PARA TODOS LOS DADOS A LO LARGO DEL EJE M-7.
UTM COORDINATION VALUES
(VALORES DE COORDINACIÓN UTM)
P1-M
F4.0
CF500
OPP.
S200
500
FOR SCHEDULES SEE SHEET S600 .
795
1020
P2-M
F4.0
S501
2600
7000
3380
P2-M
F4.0
P1-M
F4.0
CW300
5.
4
S501
4
FOR GENERAL NOTES SEE SHEET S002 .
N xxxxxxx.xxx
E xxxxxx.xxx
2
S300
4.
515
S300
TOP OF FOOTING ELEVATION ABOVE SEA LEVEL (U.N.O.) = VARIES - SEE PLAN.
400 1020
S300
SIM.
CF500
1
1
CW300
P2-M
F4.0
3
OPP.
4
CW600.B
3.
4270
S300
1
CF500
CF500
CW300
5
TOP OF PERIMETER PILASTER ELEVATION IS EQUAL TO FINISH FLOOR ELEVATION.
P2-M
F4.0
CF500
MAT1200
S300
M-3
LA CIMENTACIÓN Y LOSA DE PISO PARA EL
EQUIPO DE MOLIENDA FORMAN PARTE DE UNA
EMISIÓN DE DISEÑO SEPARADA Y NO SE
MUESTRAN EN ESTE PAQUETE.
CW300
3
2.
NOTAS PLANO DE CIMIENTO:
S300
P2-M
F4.0
FINISH FLOOR ELEVATION ABOVE SEA LEVEL = 1599.600, TYP (U.N.O.). SEE PLAN.
S601
6
7000
12230
1
3
2
T/WALL = 1596.200
7000
MILLS EQUIPMENT FOUNDATION AND SLAB-ONGRADE ARE PART OF A SEPARATE DESIGN
RELEASE AND ARE NOT SHOWN IN THIS PACKAGE
1
S601
S300
S101
OPP.
CW300
42000
CW600.A
CW300
7000
S300
CF500
7
P2-M
F4.0
1.
FASE DISEÑO / DESIGN PHASE
4
FOUNDATION PLAN NOTES:
CLIENTE / CLIENT
S200
OPP.
CF500
S200
P2-M
F4.0
CW300
4
CF500
1
CW300
7000
P2-M
F4.0
FIRMA DE DISEÑO / DESIGN FIRM
M-6
PRINTED: 1/28/2022 14:04:29
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
SPxx - ANCHOR SETTING PATTERN (ARREGLO DE ANCLAJES)
TYP UNO
7072
7072
500
35360
1
S100
FOUNDATION PLAN
(PLANO DE CIMENTACION)
1 : 150
A
M
F
KEY PLAN
(PLANO CLAVE)
TRUE
NORTH
5
0
5
1:500
10
20
25m
IK
S601
E.W. - EACH WAY (AMBOS SENTIDOS)
PK APROBO:
S601
ELEVACION SUPERIOR
CIMIENTO
T/FTG= 1594.600
DIBUJO:
3
21023-050000a-S100
3
As indicated
3
ESCALA:
1
3
CF500
S601
OPP.
S601
E.F. - EACH FACE (CADA CARA)
mm
S300
CF500
CW300
7000
4
BPxxx - BASE PLATE (PLACA BASE)
P1-M
NOTE 7
CORPORATION
P2-M
NOTE 7
REVISIONES / REVISION
P2-M
NOTE 7
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
P2-M
NOTE 7
REVISIONES / REVISIONS
P2-M
NOTE 7
CW300
P1-M
S601
M-1
11 ..............................
VBxx - VERTICAL BRACE (CONTRAVENTEO VERTICAL)
2
M-4
10 ..............................
DIAGEO - EL CHARCON - ELEVATE II PROJECT
O-8
M-7
GBxxx - GRADE BEAM (CONTRATRABE)
PROCESS DRAIN. REFER
TO PLUMBING DRAWINGS
FOR EXACT LOCATION.
DIBUJO NO:
7072
COTAS:
7072
FOUNDATION PLAN - MILLS
(PLANO DE CIMENTACIÓN - MOLIENDA)
7072
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
7072
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
500
www.vestalcorporation.com
17680
TITULO DEL PLANO:
17680
SEE OVENS FOUNDATION
PACKAGE
T: 314.439.9900
F: 314.439.9906
CFxx - CONTINUOUS FOOTING (ZAPATA CONTINUA)
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
35360
26-JAN-2022
..............................
0
M-D
2
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
FECHA / DATE
M-C
..............................
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
M-B
1
IFC (REVIEW)
KEYNOTE LEGEND
765
CW600.A
600
1
S101
2975
°
30.00
2
R=
2975
°
30.00
2375
MECHANICAL
EQUIPMENT, TYP
7
S601
TANK
9
S601
0
.00
MAT1200
EMBED PLATE EM-1,
TYP 12 PLACES
EMBED PLATE EM-3,
TYP 6 PLACES
M-3
CW600.B
5895
8870
ANCHOR LAYOUT PLAN
(PLANTA DE ARREGLO DE ANCLAJES)
PROCESS DRAIN. REFER
TO PLUMBING
DRAWINGS FOR EXACT
LOCATION.
TANK
www.vestalcorporation.com
5795
IK
MAT1000
T: 314.439.9900
F: 314.439.9906
11 ..............................
26-JAN-2022
10 ..............................
0
3075
FECHA / DATE
..............................
PK APROBO:
TANK
9
DIBUJO:
5895
..............................
21023-050000a-S101
S601
8
As indicated
EMBED PLATE EM-2,
TYP 18 PLACES
..............................
ESCALA:
7
S601
7
mm
0
.05
..............................
DIBUJO NO:
9
6
COTAS:
0
.05
..............................
CORPORATION
TANK
5
IFC (REVIEW)
5795
..............................
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
°
30.00
50
2.0
4
ANCHOR LAYOUT PLAN
(PLANTA DE ARREGLO DE ANCLAJES)
2
R=
PROCESS DRAIN. REFER
TO PLUMBING DRAWINGS
FOR EXACT LOCATION.
..............................
REVISIONES / REVISION
S601
3
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
3075
9
..............................
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
3075
FASE DISEÑO / DESIGN PHASE
8
REVISIONES / REVISIONS
CV03
T1830
TANK
3235
TANK
2
TITULO DEL PLANO:
S601
2
R=
CLIENTE / CLIENT
5105
3765
5795
..............................
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
8
R=
FIRMA DE DISEÑO / DESIGN FIRM
CV02
T1820
TANK
1340
M-7
1
DIAGEO - EL CHARCON - ELEVATE II PROJECT
S601
60
.00
°
TY
P(T
IPO
)
CV01
T1810
TANK
5095
5095
8
60
.00
°
TY
P(T
IPO
)
565
M-B
KEYNOTE LEGEND
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
1 : 55
AJ01
T1310
TANK
7300
6735
S601
60
.00
°
TY
P(T
IPO
)
265
M-6
AJ02
T1320
TANK
5095
4830
M-4
600
3535
2170
M-5
1365
PRINTED: 1/28/2022 14:04:29
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
.
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
0
.00
2
R=
.
7000
M-4
7000
M-3
7000
7000
4
S300
3
CW600.A
S300
T/WALL = 1596.200
CW600.A
CJ
CJ
MAT1200
M-C
8750
M-C.1
8750
6
..............................
7
..............................
8
..............................
9
..............................
FECHA / DATE
M-C.2 M-D
8750
7072
..............................
8750
7072
7072
7072
1000
(PISO TERMINADO)
F. F. MILS 0.00
1595.600
CW300
CF500
P2-M
CF500
F4.0
F4.0
P2-M
CF500
P1-M
CF500
F4.0
F4.0
7000
M-2
7000
M-1
7000
7000
3380
P2-M
P2-M
P2-M
P2-M
P2-M
CW300
CF500
CF500
CF500
F4.0
F4.0
CF500
F4.0
CF500
F4.0
SEE OVENS
FOUNDATION
PACKAGE
4
S100 S200
WEST FOUNDATION ELEVATION
(CIMENTACIONES - ALZADO OESTE)
1 : 150
2600
P1-M
F. F. MILS 0.00
1595.600
300
P1-M
1020
CF500
F4.0
F4.0
As indicated
7000
M-3
FOUNDATION ELEVATIONS
(ELEVACIONES DE CIMENTACIÓN)
7000
M-4
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
1200
M-5
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
M-6
TITULO DEL PLANO:
O-8 M-7
1 : 150
DIAGEO - EL CHARCON - ELEVATE II PROJECT
S100 S200
1000
3
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
EAST FOUNDATION ELEVATION
(CIMENTACIONES - ALZADO ESTE)
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
SEE OVENS
FOUNDATION
PACKAGE
www.vestalcorporation.com
CF500
F4.0
P2-M
CW300
IK
P2-M
PB APROBO:
1200
DIBUJO:
7000
T: 314.439.9900
F: 314.439.9906
CF500
F4.0
7000
515
P2-M
P1-M
7000
M-7 O-8
21023-050000a-S200
1020
7000
M-6
ESCALA:
7000
M-5
mm
300
F. F. MILS 0.00
1595.600
1000
PRINTED: 1/28/2022 14:04:33
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
(PISO TERMINADO)
M-4
DIBUJO NO:
M-3
7000
400
F4.0
CORPORATION
M-2
4270
CF500
F3.0
1 : 150
S100 S200
795
CF500
F3.0
SOUTH FOUNDATION ELVATION
(CIMENTACIONES - ALZADO SUR)
2
M-1
CF500
F3.0
CLIENTE / CLIENT
CF500
F3.0
FIRMA DE DISEÑO / DESIGN FIRM
CF500
F4.0
COTAS:
7072
5
FASE DISEÑO / DESIGN PHASE
M-B.2
..............................
REVISIONES / REVISIONS
CW600
1 : 150
S100 S200
4
11 ..............................
WALL ELEVATION
(CIMENTACIONES - ALZADO OESTE)
1
M-B M-B.1
12230
..............................
800
CW600
17735
3
10 ..............................
F. F. MILS 0.00
1595.600
1200
MAT1000
600
CJ
CW600.B
..............................
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
T/WALL = 1599.600
2
26-JAN-2022
1200
M-5
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
0
M-6
..............................
REVISIONES / REVISION
O-8 M-7
1
IFC (REVIEW)
KEYNOTE LEGEND
M-D
SEE
1150
PLAN
600
500
CW600.A
SEE PLAN &
SCHEDULE
SEE SCHEDULE
SEE SCHEDULE
BACKFILL WITH
COMPACTED
ENGINEERED FILL
IN 200mm LIFTS
CW300
SEE PLAN &
SCHEDULE
WATERPROOFING.
SEE LEGEND
CF500
SEE PLAN &
SCHEDULE
CLEAN OPEN
GRADED CRUSHED
STONE
1000
CONT. WALL REINFORCEMENT,
SEE PLAN, SCHEDULE, AND
DETAILS
MAT1200
SEE PLAN &
SCHEDULE
WATERSTOP
TYP.
PILASTER REINFORCEMENT,
SEE PLAN, SCHEDULE, AND
DETAILS
CONT. FOOTING
REINFORCEMENT, SEE PLAN,
SCHEDULE, AND DETAILS
F. F. MILS 0.00
1595.600
WRAP WITH
NON-WOVEN
GEOTEXTILE
FABRIC
100mm
PERFORATED
PIPE
SEE
SCHEDULE
SEE
SCHEDULE
CW600
800
SEE GENERAL NOTES FOR
SUBGRADE PREPARATION
NOTE:
DRAIN OCCURS ONLY ALONG GRID O-A BETWEEN GRIDS O-8 & O-13.
FOOTING REINFORCEMENT,
SEE PLAN, AND SCHEDULE
SEE GENERAL NOTES FOR
SUBGRADE PREPARATION
1
S100 S300
SECTION
(SECCIÓN)
2
1 : 20
S100 S300
SEE SCHEDULE
SEE GENERAL NOTES FOR
SUBGRADE PREPARATION
600
4000
SECTION
(SECCIÓN)
SEE SCHEDULE
SECTION
(SECCIÓN)
3
1 : 20
CLIENTE / CLIENT
100mm
PERFORATED
PIPE
FASE DISEÑO / DESIGN PHASE
1000
WRAP WITH NONWOVEN GEOTEXTILE
FABRIC
1 : 25
S100 S300
26-JAN-2022
SOG NOT INCLUDED
IN THIS PACKAGE
CLEAN OPEN
GRADED
CRUSHED
STONE
0
LENTON ANCHOR,
TYP
10mm PRE-MOLDED
JOINT FILLER AND
SEALANT, TYP
WALL BEYOND
GRADE / PAVEMENT FOR REFERENCE
ONLY, TYP
ANCLAJES, TIPO, VER TABLA DE ANCLAJE
IFC (REVIEW)
F. F. MILS 0.00
1595.600
12
180
#5 @ 600mm ± o.c.
PLACE FIRST DOWEL
100mm FROM CORNER OF
THE WALLS TO RECEIVE
CMU BLOCKS
ADDITIONAL #4
STIRRUPS @
75mm o.c.
SOG NOT INCLUDED
IN THIS PACKAGE
LÍNEA DE CENTRO DE ARREGLO DE PERNOS
LÍNEA DE CENTRO DE LA COLUMNA
FECHA / DATE
VERTICAL BARS, SEE SCHEDULE,
PROVIDE STANDARD HOOK INTO
FOUNDATION
11
850
CMU FOR REFERENCE
ONLY. NOT INCLUDED
IN THIS PACKAGE
10mm PRE-MOLDED
JOINT FILLER AND
SEALANT, TYP
VARÍA
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
REVISIONES / REVISION
CMU FOR REFERENCE
ONLY. NOT INCLUDED
IN THIS PACKAGE
4
650
300
#5 @ 600mm ± o.c.
PLACE FIRST DOWEL
100mm FROM
CORNER OF THE
WALLS TO RECEIVE
CMU BLOCKS
IGUAL
REVISIONES / REVISIONS
300
2
2000 MAX.
100
100
EVERY THIRD CELL
600 ±
CW300
KEYNOTE LEGEND
M-D M-C.2
M-B M-B.1
100mm
PERFORATED
PIPE
1 : 25
S100 S300
O-8 M-7
1200
M-6
7000
1 : 25
S100 S300
M-5
7000
SEE SCHEDULE
7
M-4
M-3
7000
7000
MAT1000
MAT1200
1200
1000
SEE GENERAL NOTES FOR
SUBGRADE PREPARATION
SEE SCHEDULE
1 : 25
600
SEE SCHEDULE
F. F. MILS 0.00
1595.600
2000
12230
S100 S300
CW600.B
SEE SCHEDULE
600
4
1365
8
S100 S300
SECTION
(SECCIÓN)
1 : 75
1 : 25
www.vestalcorporation.com
IK
S100 S300
6
SECTION
(SECCIÓN)
PB APROBO:
5
SECTION
(SECCIÓN)
STYROFOAM FILLER (RELLENO DE POLIESTIREN AISLANTE)
DIBUJO:
SECTION
(SECCIÓN)
10mm JOINT FILLER AND SEALANT.
(RELLENO DE JUNTAS Y SELLADORE DE 10mm)
21023-050000a-S300
STYROFOAM FILLER (RELLENO
DE POLIESTIREN AISLANTE)
As indicated
WRAP WITH
NON-WOVEN
GEOTEXTILE
FABRIC
NOTE:
FOR BALANCE OF INFO
SEE SECTION 2 / S300
NOTE:
FOR BALANCE OF INFO
SEE SECTION 1 / S300
ESCALA:
MAT1000
SEE PLAN &
SCHEDULE
10mm JOINT FILLER
AND SEALANT.
(RELLENO DE JUNTAS
Y SELLADORE DE
10mm)
mm
TENSION LAP
DIBUJO NO:
2000
STYROFOAM FILLER
(RELLENO DE
POLIESTIREN
AISLANTE)
F. F. MILS 0.00
1595.600
SECTION
(SECCIÓN)
F4.0
BEYOND
COTAS:
CF500
TENSION LAP
NOTE:
FOR BALANCE OF INFO
SEE SECTION 1 / S300
SEE
SCHEDULE
CW600
P2-M
F4.0
F4.0
SEE
SCHEDULE
1000
1200
1200
4000 MAX.
CLEAN OPEN
GRADED
CRUSHED
STONE
CW300
10mm JOINT FILLER AND SEALANT.
(RELLENO DE JUNTAS Y SELLADORE DE 10mm)
T: 314.439.9900
F: 314.439.9906
CW300
CW300
WATERSTOP
TYP.
SEE SCHEDULE
F. F. MILS 0.00
1595.600
CORPORATION
MAT1000
#5 @ 200
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
CW600.A
SEE PLAN &
SCHEDULE
#10 @ 300
FOUNDATION SECTIONS AND DETAILS
(CIMENTACION SECCIONES Y DETALLES)
MAT1200
F. F. MILS 0.00
1595.600
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
#5 @ 200
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
#10 @ 300
TITULO DEL PLANO:
MAT1200
F. F. MILS 0.00
1595.600
SOG NOT INCLUDED
IN THIS PACKAGE
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
SEE SCHEDULE
SOG NOT INCLUDED
IN THIS PACKAGE
(6) #10 @ 300
200 180
#5 @ 600mm ± o.c.
PLACE FIRST DOWEL
100mm FROM CORNER OF
THE WALLS TO RECEIVE
CMU BLOCKS
#5 @ 600mm ± o.c.
PLACE FIRST DOWEL 100mm FROM
CORNER OF THE WALLS TO RECEIVE
CMU BLOCKS
SOG NOT INCLUDED
IN THIS PACKAGE
(3) #10 @ 300
300
DIAGEO - EL CHARCON - ELEVATE II PROJECT
SEE SCHEDULE
180 850
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
300
200 180
650
FIRMA DE DISEÑO / DESIGN FIRM
500
#5 @ 600mm ± o.c.
PLACE FIRST DOWEL 100mm
FROM CORNER OF THE
WALLS TO RECEIVE CMU
BLOCKS
1000
PRINTED: 1/28/2022 14:04:37
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
300
M-B M-B.1
1150
M-B M-B.1
TENSION LAP SPLICE "B"
(EMPALME A TENSIÓN "B")
BAR SIZE
(TAMAÑO
DE VARILLA)
TOP BARS
(VARILLAS
SUPERIORES)
OTHER BARS
(OTRAS
VARILLAS)
#3
650mm
500mm
COMPRESSION
LAP SPLICE
(EMPALME A
COMPRESIÓN)
BAR SIZE
(TAMAÑO
DE VARILLA)
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
TENSION LAP SPLICE "B"
(EMPALME DE TENSIÓN "B") COMPRESSION
LAP SPLICE
TOP BARS
OTHER BARS (EMPALME DE
(VARILLAS
(OTRAS
COMPRESIÓN)
SUPERIORES) VARILLAS)
950mm
600mm
#6
1150mm
850mm
600mm
#8
2050mm
1600mm
800mm
#8
1850mm
1450mm
800mm
#10
2600mm
2000mm
1000mm
#10
2350mm
1800mm
1000mm
#12
3050mm
2400mm
1150mm
#12
2750mm
2150mm
1150mm
d
D
135 DEGREE
(135 GRADOS)
.
IN
M N.
m I
m M
75 mm
R 5
O O7
6 D 6D
(
d
2
S500
3
S500
1 : 20
135 DEGREE
(135 GRADOS)
BACK GOUGE
(SANEADO DE
RAÍZ)
#4
SEISMIC STIRRUP/ TIES
(ESTRIBOS SÍSMICOS/ AMARRES)
BAR
SIZE
(VARILLA#)
135°
A or G
A or G
H
40mm
100mm
100mm
65mm
50mm
115mm
115mm
75mm
(LONGITUD DE TRASLAPE)
(LONGITUD DE TRASLAPE)
135°
D
A or G
H
#3
40mm
115mm
75mm
#4
50mm
115mm
75mm
3mm
TYPICAL CONCRETE REINFORCING @ CORNER DETAIL
(CONCRETO REFORZADO TIPICO EN DETALLE DE ESQUINA)
1 : 16
MECHANICAL COUPLER
(COPLE MECANICO)
MANUFACTURER
(FABRICANTE)
BACK GOUGE
(SANEADO DE
RAÍZ)
INTERSECTIONS
(INTERSECCIONES)
ONE LAYER
(UNA CAPA)
REINFORCEMENT, SEE APPROPRIATE SECTIÓN FOR
ADDITIONAL INFORMATION
(REFUERZO, VER LA SECCION CORREPONDIENTE
PARA INFORMACIÓN ADICIONAL)
PRODUCT LINE
(LINEA DEL
PRODUCTO)
DEXTRA
BARTEC
DAYTON
TAPER LOCK
DAYTON
BAR-LOCK
BARSPLICE
BPI-GRIP XL
3 mm
#3
90°
LAP SPLICE
MECHANICAL COUPLER PER SCHEDULE
(EMPALME MECÁNICO VER TABLA)
REINFORCING SPLICE SCHEDULE
(TABLA DE EMPALME DE REFUERZO)
3 mm.
D
ALTERNATE HOOK
(GANCHOS ALTERNADOS)
LAP SPLICE
TWO LAYERS
(DOS CAPAS)
45°
STIRRUP HOOKS (TIE BEND SIMILAR)
(GANCHOS EN ESTRIBOS (AMARRE DOBLEZ SIMILAR)
ONE LAYER
(UNA CAPA)
CORNERS
(ESQUINAS)
Tc = 350 KG/CM2 - NORMAL WEIGHT CONCRETE (Tc = 350 KG/CM2 - CONCRETO DE PESO NORMAL)
45° TO 60°
BAR
SIZE
(VARILLA#)
TWO LAYERS
(DOS CAPAS)
3 mm
65mm
155mm
140mm
95mm
#5
65mm
140mm
95mm
#6
115mm
305mm
205mm
115mm
#6
115mm
205mm
115mm
#8
140mm
355mm
230mm
135mm
#8
140mm
230mm
135mm
#10
155mm
410mm
270mm
155mm
#10
155mm
270mm
155mm
SINGLE - BEVEL - GROOVE WELD
(SOLDADURA DE PENETRACION SENCILLA)
NOTES:
1. ASTM A706 REBAR ONLY
SINGLE - V - GROOVE WELD
(SOLDADURA DE PENETRACION EN V)
(NOTAS:
LENTON
1
S500
1:5
6
S500
LOCK
1. UNICAMENTE EN VARILLAS ASTMA706)
DETAILS OF REINFORCEMENT (DETALLES DE REFUERZO)
REINFORCEMENT BAR HOOK DIMENSIONS
(DIMENSIONES DE BARRA DE GANCHO DE REFUERZO)
POSITION TAPER THREADED GRIP TWIST
(EMPALME VARILLA MACHO HEMBRA)
BARSPLICE
REINFORCING BAR FIELD WELDING
(SOLDADURA EN CAMPO DE VARILLAS DE REFUERZO)
NOTES
NOTAS:
1.
1.
ALL COUPLERS LISTED IN TABLE ARE PERMITTED TO BE USED
UNLESS RESTRICTION PROVIDED IN SPECIFIC DETAIL.
SUBSTITUTIONS ARE ALLOWED FOR EQUAL PRODUCTS NOT
SHOWN IF PRODUCT IS SUBMITTED TO ENGINEER AND
APPROVED AS EQUAL FOR USE.
1 : 16
TODOS LOS EMPALMES MOSTRADOS EN LA TABLA SE PODRAN
USAR A MENOS QUE SE INDIQUE UNA RESTRICCIÓN EN ALGUN
DETALLE ESPECÍFICO
ESTAN PERMITIDAS LAS SUSTITUCIONES PARA PRODUCTOS IGUALES NO MOSTRADOS
SI EL PRODUCTO SE SUBMITE A APROBACION POR EL INGENIERO PARA SU USO
1 : 16
SPLICE
TOP OR BOTTOM BARS
(PARTE SUP. O INF. DE
VARILLAS)
SPLICE LENGTH +300 mm
(LONGITUD DE EMPALME +300mm)
SPLICE
(1500 mm MIN)
STAGGER SPLICE OF TOP & BOTTOM
REINF, NO TWO ADJACENT BARS ARE
SPLICED AT THE SAME POINT
(ESCALONAR EMPALME DE REFUERZO
PARTE INFERIOR Y SUPERIOR, NO SE
DEBERÁN COLOCAR LOS EMPALMES DE
DOS VARILLAS ADYACENTES EN EL MISMO
PUNTO)
5
S500
HORIZ BEAM BAR TYP
(REFUERZO HORIZONTAL DE VIGAS)
BARTEC
LENTON
FORM SAVER
MECHANICAL END ANCHOR PER SCHEDULE
(COPLE ANCLAJE MECÁNICO EN EL EXTREMO)
REINFORCEMENT, SEE APPROPRIATE SECTION FOR ADDITIONAL
INFORMATION
(VER LA SECCIÓN CORRESPONDIENTE PARA INFORMACIÓN ADICIONAL)
END ANCHOR
(ANCLAJE EN EXTREMO)
MANUFACTURER
PRODUCT LINE
(FABRICANTE) (LINEA DEL PRODUCTO)
FOR SLAB, MAT FOUNDATION & CONTINUOUS FOOTINGS
(PARA FIRME, LOSA DE CIMENTACIÓN Y ZAPATAS CORRIDAS)
DEXTRA
DEXTRA
BARTEC
LENTON
TERMINATOR
TYPICAL STAGGERED REBAR SPLICE DETAIL
(DETALLE TÍPICO DE REFUERZO ESCALONADO)
1 : 16
7
S500
MODEL # PER REINFORCEMENT SIZE
(MODELO CON BASE AL NUMERO DE VARILLA)
6
8
10
BEASC #6 BEASC #8 BEASC #10
12
REQUIREMENTS FOR END ANCHOR USE
(REQUERIMIENTOS PARA USO DE COPLES DE
ANCLAJE EN LOS EXTREMOS)
N/A
EL20D14
EL25D14
EL32D14
EL38D14
96mm
127mm
132mm
180mm
48mm
64mm
80mm
90mm
MIN BAR SPACING OC
(CLARO LIBRE MINIMO ENTRE VARILLAS)
MIN CONCRETE COVER TO CENTER OF REINF BAR
(RECUBRIMIENTO MÍNIMO DEL CONCRETO AL CENTRO VARILLA
REFUERZO)
REINFORCING MECHANICAL COUPLER SCHEDULE
(TABLAS DE COPLES MECÁNICOS PARA EMPALME DE VARILLAS.)
1 : 16
As indicated
S500
TYPICAL TYPE II MECHANICAL REBAR LAP SPLICE DETAIL
(DETALLE TÍPICO DE EMPALME MECÁNICO DE REFUERZO ESCALONADO TIPO II)
ESCALA:
4
MANUFACTURER
PRODUCT LINE
(FRABRICANTE) (LINEA DEL PRODUCTO)
TYPICAL DETAILS
(DETALLES TÍPICOS)
HORIZ BEAM BAR TYP
(REFUERZO HORIZONTAL DE VIGAS)
FOR COLUMNS AND BEAMS
(PARA COLUMNAS Y VIGAS)
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
FORM SAVER COUPLER
(CIMBRA PARA COPLES DE ANCLAJE DE VARILLAS)
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
FORM SAVER ANCHOR PER
SCHEDULE
(CIMBRA CON COPLE PARA ANCLAJE
DE VARILLAS VER TABLA)
TITULO DEL PLANO:
REINFORCEMENT, SEE
APPROPRIATE SECTION FOR
ADDITIONAL INFORMATION
(ACERO DE REFUERZO, VER
LA SECCIÓN
CORRESPONDIENTE PARA
INFORMACION ADICIONAL)
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
MECHANICAL REBAR SPLICE TYP
(EMPALME MECÁNICO TIPO)
600
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
CONC COLD JOINT
(JUNTA FRÍA EN CONCRETO)
DIAGEO - EL CHARCON - ELEVATE II PROJECT
PRINTED: 1/28/2022 14:04:39
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
#5
www.vestalcorporation.com
1250mm
IK
#6
PK APROBO:
500mm
DIBUJO:
750mm
T: 314.439.9900
F: 314.439.9906
950mm
21023-050000a-S500
#5
mm
500mm
FECHA / DATE
800mm
CORNER BARS TO
MATCH WALL
REINFORCING
(LAS VARILLAS DE
LAS ESQUINAS
DEBEN SER LAS
MISMAS QUE LAS
DEL ARMADO DE
LOS MUROS)
DIBUJO NO:
D
D
1050mm
3. OTHER MEMBERS: CONCRETE COVER LARGE AND EQUAL db AND C.C. BAR SPACING LARGE OR EQUAL 3db.
WHERE THESE CONDITIONS ARE NOT MET TABULATED VALUES SHALL BE MULTIPLIED BY A FACTOR OF 1.5.
(OTROS ELEMENTOS ESTRUCTURALES; RECUBRIMIENTO EN EL CONCRETO MAYOR O IGUAL QUE EL db Y EL ESPACIAMIENTO CENTRO A
CENTRO DE VARILLAS MAYOR O IGUAL QUE 3db)
(DONDE ESTAS CONDICIONES NO SE CUMPLAN LOS VALORES MOSTRADOS EN LA TABLA DEBERÁN SER MULTIPLICADOS POR UN VALOR
DE 1.5)
H
H
D
(GANCHO A O G)
HOOK A OR G
(GANCHO A O G)
HOOK A OR G
D - BEND DIAMETER
(D- DIAMETRO DE DOBLEZ)
A OR G
D
#5
2. ALL TABULATED REBAR SHALL SATISFY THE FOLLOWING BEAMS AND COLUMNS:
CONCRETE COVER LARGE OR EQUAL db AND C.C. BAR SPACING LARGE OR EQUAL 2 db AND STIRRUPS OR
TIES THROUGHOUT DEVELOPMENT LENGTH (Ld) NOT LESS THAN THE CODE MINNIMUM.
(TODOS LOS VALORES MOSTRADOS EN LA TABLA PARA LAS VARILLAS DE REFUERZO DEBERÁN CUMPLIR CON LO SIGUIENTE):
(EN VIGAS Y COLUMNAS: RECUBRIMIENTO EN EL CONCRETO MAYOR O IGUAL QUE EL DIAMETRO DE LA VARILLA Y LA SEPARACION
CENTRO A CENTRO ENTRE VARILLAS MAYOR O IGUAL QUE 2db Y EN ESTRIBOS EN TODA LA LONGITUD DE DESAROLLO (Ld) NO MENOR
A LO QUE ESPECIFICA EN EL REGLAMENTO.
6D
DIMENSION
400mm
1. THESE VALUES ARE BASED ON ACI/ 318-14 FOR GRADE 60 UNCOATED REINFORCING ALL
LAPSPLICES SHALL BE TYPE "B" TENSION SPLICES U.N.O.
(ESTOS VALORES ESTAN BASADOS EN AC/ 318-14 PARA ACERO GRADO 60 SIN RECUBRIMIENTO
TODOS LOS EMPALMES DEBERÁN SER TIPO "B" A MENOS QUE SE INDIQUE OTRA COSA).
D
90 DEGREE
(90 GRADOS)
600mm
NOTE (NOTA):
STANDARD HOOK AT LONGITUDINAL BARS
GANCHO ESTANDAR EN VARILLAS LONGITUDINALES)
d
750mm
Tc = 300 KG/CM2 - NORMAL WEIGHT CONCRETE (Tc = 300 KG/CM2 - CONCRETO DE PESO NORMAL)
BEND AT STIRRUPS
(DOBLEZ EN
ESTRIBOS)
FOR #3, #4, #5 - 6d
FOR #6, #7, #8 -12d
#4
COTAS:
8d
400mm
CORPORATION
#10 TO #11 (#32 AL #36)
650mm
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
6d
HOOK TO
135°(DOBLEZ A
HOOK TO 90°
(DOBLEZ A 90°)
BEND DIAMETER D (DIAMETRO DE DOBLEZ D)
#3 TO #8 (#10 AL #25)
850mm
6d
4d
BAR SIZE (VARILLA #)
#4
0
d
EXTENSION
(LONGITUD DE TRASLAPE)
IFC (REVIEW)
D
12d
d
180 DEGREE
HOOK
(DOBLEZ A
180 GRADOS)
(LONGITUD DE TRASLAPE)
CLIENTE / CLIENT
d
D
N
O
6d
SI
N
TE
EX
90 DEGREE
HOOK
(DOBLEZ A 90
GRADOS)
LAP SPLICE
FIRMA DE DISEÑO / DESIGN FIRM
ALTERNATE BEAM
REINFORCEMENT(REFUERZO
(4d
TYPICAL BEAM
REINFORCEMENT(ARREGLO
TIPO DE REFUERZO EN VIGAS)
4
D I d BE
AM N
ET D D
RO IA
S ME
(4d 4d
DE TE
DI BE
DO R
AM N
BL
ET D D
EZ
RO IAM
)
S D ET
E D ER
OB
LE
Z)
Smin
d
Smin=25 ó d
LAP SPLICE
300mm
REVISIONES / REVISION
450mm
FASE DISEÑO / DESIGN PHASE
600mm
REVISIONES / REVISIONS
#3
300mm
26-JAN-2022
d
.
SEAL AS REQ'D
(SELLO COMO SE REQUIERA)
8
MANGA
9
TUBO O TUBERIA
10
CARA INFERIOR DE LA VIGA DE PISO
11
50mm LIBRE AL REFUERZO
12
LONGITUD DE TRASLAPE PARA TENSION
13
MANGA. MINIMO
14
ESPESOR DE LOSA
15
AJUSTAR EL REFUERZO DEL MURO PARA ABERTURAS LIBRES DONDE
LAS BARRAS HORIZONTALES O VERTICALES SEAN CORTADAS PARA
PROVEER LAS ABERTURAS, AGREGAR REFUERZOS HORIZONTALES Y
VERTICALES A AMBOS LADOS DE LAS ABERTURAS (# DE BARRAS A
CADA LADO DEBERAN SER 1/2 DE LAS BARRAS CORTADA PERO NO
MENOS QUE UNA )
16
ABERTURAS MULTIPLES - DETALLE "A"
17
CORTE DE BARRA VERTICAL EN ABERTURA
18
CORTE DE BARRA HORIZONTAL EN ABERTURA
19
DIAMETRO MAYOR A DOS MANGAS ADJACENTES (MINIMO)
20
LONGITUD EN EXCESO ACUMULADA MAXIMA DE LA ABERTURA EN EL
MURO UNIDA POR DOS PILASTRAS O POR DOS ELEMENTOS
COLINDANTES, NO DEBEN EXCEDER DEL 10% DE LA LONGITUD
DEL MURO
21
2-#5X5'-0" (1500mm) BARRAS DIAGONALES
SEE PLAN
(VER PLANO)
PIPE PENETRATION @ WALL
(PENETRACIÓN DE TUBERÍA @ MURO)
1 : 10
22
23
VERT. BAR CUT AT
OPENING
17
16
SINGLE OPENINGS - DETAIL "B"
ADJUST WALL REINF. TO CLEAR OPENINGS WHERE VERT. OR HORIZ. BARS ARE
CUT TO PROVIDE OPENINGS, ADD ADDITIONAL VERT. & HORIZ. REINF. ON BOTH
SIDES OF OPENING (# OF BARS ON EACH SIDE TO BE 1/2 OF BARS THAT ARE
CUT, BUT NOT LESS THAN ONE)
(AJUSTAR EL REFUERSO DE LA PARED PARA LIBRAR LAS APERTURAS DONDE
DONDE SE CORTAN ARMADURAS DE REFUERSO VERTICALES U HORIZONTALES
EN AMBOS LADOS DE LA APERTURA (# DE BARRAS A CADA LADO SERA 1/2 DE
LAS BARRAS QUE SE CORTAN PERO NO MENOS DE UNA))
2-#5x5'-0"(1500mm) DIAGONAL BARS
22
27
29
TOPE DE TRABE DE CIMENTACION
30
0" ACEPTABLE
31
ABIERTO
32
MURO VER PLANO
TOP OF GRADE BEAM
(COTA SUPERIOR VIGA DE PISO)
33
CLAVIJAS DE TRABE DE CIMENTACION
34
NOTA:
PARA INFORMACIÓN ADICIONAL VER DETALLE "A" Y DETALLE "B"
GRADE BEAM SEE PLAN
(VIGA EN PISO, VER PLANO)
35
TRASLAPE DE TENSIÓN (TIPO)
36
ABIERTO
OPENING AT BOT OF WALL AT TOP OF GRADE
BEAM CONDITION - DETAIL "C"
21
ABBREVIATION LEGEND (LEYENDA DE ABREVIACIONES):
PD - PIPE DIAMETER (DIÁMETRO DE LA TUBO)
SD - SLEEVE DIAMETER (DIÁMETRO DE LA MANGA)
CL - CENTERLINE (LINEA CENTRAL)
MAXIMUM CUMULATIVE OPENING LENGTH IN EXCESS OF THAT SHOWN IN A WALL BOUNDED BY TWO PILASTERS OR
TWO BOUNDARY ELEMENTS SHALL NOT EXCEED 10% OF WALL LENGTH.
(LA LONGITUD MAXIMA ACUMULADA DE LAS APERTURAS EXCEDIENDO LA CORRESPONDIENTE A LA DE UNA PARED
CONFINADA ENTRE DOS PILASTRAS O DOS ELEMENTOS NO DEBERA EXCEDER EL 10% DE LA LONGITUD DE ESTA)
TYPICAL OPENINGS IN CONCRETE WALL DETAIL
(DETALLE TIPO DE ABERTURAS EN MURO DE CONCRETO)
3
t
t/3
MAT REINF NOT SHOWN FOR
CLARITY, SEE SECTIONS AND
SCHEDULE
(EL REFUERZO DE LA LOSA DE
CIMENTACIÓN NO SE MUESTRA POR
CLARIDAD, VER SECCIONES Y
TABLA)
NOTE:
FOR BALANCE OF INFORMATIONS SEE
SLAB ON GRADE PACKAGE.
4
S501
SEE PLAN & SCHEDULE
FOR WALL INFO
(VER PLANO/TABLA
PARA INFORMACIÓN
DEL MURO)
TYPICAL SECTION AT DOOR
(SECCIÓN TÍPICA EN LA PUERTA)
1 : 15
3/4" (19mm) SMOOTH
DOWEL @ 450 OC
(ANCLAJE LISO DE 3/4"
(19mm) @ 450 A CENTRO)
5
S501
SYNKO-FLEX FR
WATERSTOP OR
APPROVED EQUAL
(WATERSTOP SYNKO-FLEZ
FR O IGUAL APROBADO)
WALL CONSTRUCTION JOINT TYP
(JUNTA DE CONSTRUCCIÓN DE MURO, TIPO)
1 : 10
3/4" (19mm) SMOOTH
DOWEL @ 450 OC
(ANCLAJE LISO DE 3/4"
(19mm) @ 450 A
CENTRO)
6
S501
WALL CONTROL JOINT, TYP
(JUNTA DE CONTROL DE MURO, TIPO)
1 : 10
7
S501
TYPICAL WATERSTOP DETAIL
(DETALLE TIPO DE WATERSTOP - BANDA IMPERMEABLE)
1 : 10
As indicated
t/2
300
21
MAT FDN SEE PLAN AND
SCHEDULE
(LOSA DE CIMENTACIÓN - VER
PLANTA Y TABLA)
ESCALA:
9
SEE PLAN
CONTAINMENT WALL / CURB,
SEE PLAN AND SECTIONS
(MURO DE CONTENCIÓN /
BORDILLO, VER PLANTA Y
SECCIONES)
TYPICAL DETAILS
(DETALLES TÍPICOS)
SLAB ON GRADE 7
SEE S.O.G. PACKAGE
FIN FLOOR
LUBRICATE
(LUBRICAR)
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
LUBRICATE
(LUBRICAR)
SYNKO-FLEX FR
WATERSTOP OR
APPROVED EQUAL
(WATERSTOP SYNKO-FLEZ
FR O IGUAL APROBADO)
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
#5 DOWEL @ 300
JOINT SEALANT
TYP
(SELLADOR DE
JUNTA, TIPO)
TITULO DEL PLANO:
6
3/4" (19mm) SMOOTH
DOWEL @ 450 OC
(ANCLAJE LISO DE 3/4"
(19mm) @ 450 A CENTRO)
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
600
JOINT SEALANT
TYP
(SELLADOR DE
JUNTA, TIPO)
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
3/4" (19mm) SMOOTH
DOWEL @ 450 OC
(ANCLAJE LISO DE 3/4"
(19mm) @ 450 A CENTRO)
REINF SEE SECTIONS ON
PLAN
(REFUERZO - VER
SECCIONES EN PLANO)
6mm MAX.
6mm MAX.
t/6
TYP (TIPO)
4
t/2
1
t/6
TYP (TIPO)
GRID
DIAGEO - EL CHARCON - ELEVATE II PROJECT
1 : 15
S501
750
PRINTED: 1/28/2022 14:04:40
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
MULTIPLE OPENINGS - DETAIL "A"
ADDITIONAL VERT. BARS ADDED EA.
SIDE OF OPENING PER DETAIL "A"
(REFUERZO VERTICAL ADICIONAL.
ANADIDAS A CADA LADO DE LA
APERTURA SEGUN DETALLE "A")
30
t
35
TENSION
LAP
(TYP.)
35
OPEN
www.vestalcorporation.com
OPEN
TENSION
LAP
(TYP.)
31
IK
36
28
ABERTURA AL FONDO DEL MURO AL TOPE DE LA CONDICION DE
LA TRABE DE CIMENTACION - DETALLE "C"
TRABE DE CIMENTACION VER PLANO
27
PK APROBO:
35
26
FIRMA DE DISEÑO / DESIGN FIRM
18
25
VERT. BARS PER WALL SECTION
(REFUEZO VERTICAL DE
ACUERDO A LA SECCION DE LA
PARED)
WALL SEE PLAN
ADDITIONAL HORIZ. BARS
(VER PLANO DE PARED)
ADDED EA. SIDE OF OPENING
PER DETAIL "A"
(REFUERZO VERTICAL
NOTE:
ADICIONAL. ANADIDAS A
SEE DETAIL "A" AND DETAIL
CADA LADO DE LA APERTURA
"B" FOR ADDITIONAL
SEGUN DETALLE "A")
INFORMATION
(NOTA:
VERT. BARS CUT DUE TO
VERS DETALLE "A" Y
OPENING
DETALLE "B" PARA
(SIM. @ HORIZ. BARS)
INFORMACION ADICIONAL)
(REFUEZO VERTICAL
CORTADO POR LA
APERTURA (IGUAL PARA
GRADE BEAM DWLS
BARRAS HORIZONTALES)
(DOVELAS DE VIGA EN PISO)
0" ACCEPTABLE
TENSION
LAP
(TYP.)
24
HORIZ. BAR CUT
AT OPENING
(CORTE DE BARRA
HORIZONTAL EN
LA APERTURA)
TENSION
LAP
(TYP.)
35
LARGER DIAMETER OF TWO
ADJACENT SLEEVES (MINIMUM)
(COMO MINIMO IGUAL AL MAYOR
DE LOS DIAMETROS DE DOS
CAMISAS CONTIGUAS)
ABERTURAS SIMPLES - DETALLE "B"
BARRA VERTICALES ADICIONALES A CADA LADO DE LA ABERTURA VER DETALLE "A"
BARRA VERTICALES CORTADAS DEBIDO A ABERTURAS (SIM
@BARRAS HORIZONTALES)
BARRA HORIZONTALES ADICIONALES A CADA LADO DE LA ABERTURA
CONFORME AL DETALLE "A"
BARRA VERTICALES CONFORME A SECCION DEL MURO
DIBUJO:
S501
T: 314.439.9900
F: 314.439.9906
1 : 16
21023-050000a-S501
2
mm
TYPICAL FOOTING CONSTRUCTION JOINT DETAIL
(DETALLE TIPO DE CONSTRUCCIÓN DE JUNTA EN VIGA DE CIMENTACIÓN/ZAPATA)
DIBUJO NO:
JOINT LOCATION SHOULD BE PER APPROVED SHOP DRAWINGS.
(LA UBICACION DE LA JUNTA DEBE SER SEGUN PLANOS DE OBRA APROBADOS)
TOPE SUPERIOR DE LOSA DE LA VIGA DE CIMENTACIÓN
COTAS:
2.
7
CORPORATION
FOR FOOTING DEPTH OF 600mm. OR LESS PROVIDE A SINGLE SHEAR KEY CENTERED.
(PARA CIMIENTOS DE 600MM DE PROFUNDIDAD O MENOR, UTILIZA UNA SOLA CLAVE A CORTANTE CENTRADA)
ESTRIBOS DOBLES DE AMBOS LADOS @ 75mm A CENTRO
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
1.
6
26-JAN-2022
(PENDIENTE 1%)
VER TABLA PARA EL DIAMETRO MAXIMO DEL AGUJERO
0
SLOPE 1%
5
IFC (REVIEW)
(PENETRACIÓN EN MURO)
WALL PENETRATION
115
150
115
(FIELD VERIFY LOCATION OF PIPE +
REQUIRED DIM. FOR SEAL)
(VERIFICAR EN CAMPO UBICACIÓN DE TUBO +
DIAM. REQUERIDO PARA SELLO)
FECHA / DATE
PARA VIGAS DE PISO CON PERALTE DE 600mm O MENORES,
PROPORCIONAR UNA JUNTA SIMPLE CON LLAVE DE CORTANTE
CENTRADA AL PERALTE.
LA UBICACION DE LA JUNTA DEBERA SER DE ACUERDO A LOS
PLANOS DE TALLER APROBADOS
REVISIONES / REVISION
3
4
BACKER ROD
(VARILLA DE RESPALDO)
NOTES (NOTAS):
S501
PARA EL RUEFUERZO PARA LAS VIGAS DE PISO VER PLANO
SONATUBE
(SONOTUBO)
FOR FOUNDATION SEE PLAN
(PARA CIMIENTOS VER PLANO)
1
2
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
FASE DISEÑO / DESIGN PHASE
40
TYP
40
EL REFUERZO SERA CORRIDO EN LAS JUNTAS DE CONSTRUCCION
CLIENTE / CLIENT
REINFORCEMENT TO BE CONTINUOUS
AT CONSTRUCTION JOINT
(EL REFUERZO DEBE SER CONTINUO
EN LAS JUNTAS DE CONSTRUCCION)
1
REVISIONES / REVISIONS
KEYNOTE LEGEND
.
3000
4000
1000
1000
(11) #10 EA. WAY TOP & BOT.
(14) #10 EA. WAY TOP & BOT.
.....
.....
COMMENTS
(OBSERVACIONES)
.....
.....
WIDTH IN MM
(ANCHO EN MM)
THICKNESS IN MM
(ESPESOR EN MM)
CF500
1400
GRAN TOTAL (GRAND TOTAL): 3
500
(5) #5
CW300
CW600
CW600.A
CW600.B
GRAN TOTAL (GRAND TOTAL): 9
300
600
600
600
6
PARTE INFERIOR/TUERCA
7
NIVEL SUPERIOR DE CONCRETO
8
TUERCA
9
NO UTILIZADO
10
PUNTO DE SOLDADURA
#5 @ 300mm (TOP & BOT.)
REINFORCING (REFUERZO)
WALL THICKNESS IN MM
(ESPESOR DE MURO)
PROYECCIÓN DE ROSACADO MÍNIMO 200mm
REINFORCING (REFUERZO)
LONG DIRECTION
SHORT DIRECTION
(DIRECCIÓN LARGA)
(DIRECCIÓN CORTA)
CONCRETE WALL REINFORCING SCHEDULE (TABLA DE REFUERZO DE MURO DE CONCRETO)
MARK
(MARCA)
5
HORIZONTAL
EXTERIOR FACE INTERIOR FACE
CENTER OF WALL ADDITIONAL TOP AND BOTTOM EXTERIOR FACE
(CARA EXTERIOR) (CARA INTERIOR) (CENTRO DEL MURO)
(ADICIONAL SUP. E INF.)
(CARA EXTERIOR)
#4 @ 300 OC
#5 @ 150 OC
#5 @ 150 OC
#5 @ 300 OC
#4 @ 300 OC
#5 @ 150 OC
#5 @ 150 OC
#5 @ 300 OC
VERTICAL
INTERIOR FACE
(CARA INTERIOR)
#6 @ 300 OC
#6 @ 150 OC
#6 @ 300 OC
#5 @ 300 OC
#6 @ 300 OC
#6 @ 150 OC
#6 @ 300 OC
#5 @ 300 OC
CENTER OF WALL
(CENTRO DEL MURO)
COMMENTS
(COMENTARIOS)
SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS
SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS
SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS
SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS
REVISIONES / REVISION
MARK
(MARCA)
NO UTILIZADO
FECHA / DATE
CONCRETE CONTINUOUS FOOTING SCHEDULE (TABLA DE ZAPATA CONTINUA DE CONCRETO)
4
FASE DISEÑO / DESIGN PHASE
F3.0
3000
F4.0
4000
GRAN TOTAL (GRAND TOTAL): 16
REINFORCING (REFUERZO)
REINFORCING E.W. - U.N.O.
(REFUERZO E.0. – A MENOS
LONG DIRECTION
SHORT DIRECTION
QUE SE INDIQUE OTRO)
(DIRECCCION LARGA) (DIRECCION CORTA)
PLACA DE 13mm x 75mm x 75mm EN VARILLA DE ANCLAJE DE 32mm
PLACA DE 10mm x 50mm x 50mm EN VARILLA DE ANCLAJE DE 19mm
PLACA DE 13mm x 90mm x 90mm EN VARILLA DE ANCLAJE DE 38mm
MARK
(MARCA)
PILASTER WIDTH IN MM
(ANCHO DE DADO)
P1-M
P2-M
GRAN TOTAL (GRAND TOTAL): 22
975
750
PILASTER LENGTH IN MM
(LARGO DE DADO)
PILASTER DIAMETER IN MM
(DIÁMETRO DE DADO)
VERTICAL BARS
(VARILLAS VERTICALES)
TIES REINF
(ESTRIBOS DE REFUERZO)
COMMENTS
(COMENTARIOS)
(16) #10
(12) # 10
#4 @ 200 mm OC
#4 @ 200 mm OC
SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS
SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS
1150
1150
CONCRETE MAT SCHEDULE (TABLA LOSA DE CONCRETO DE CIMENTACION)
MARK
(MARCA)
REINF. E.W. - U.N.O.
(REFUERZO E.W. - U.N.O.)
MAT1000
MAT1200
GRAN TOTAL (GRAND TOTAL): 2
REINF. SHORT DIR.
(REFUERZO DIRECCIÓN CORTA)
REINF. LONG DIR.
(REFUERZO DIRECCIÓN LARGA)
REMARKS (OBSERVACIONES)
#10 @ 300 E.W. T&B
#10 @ 300 E.W. T&B
#10 @ 300 E.W. T&B
#10 @ 300 E.W. T&B
************************
************************
CLIENTE / CLIENT
CONCRETE PILASTER SCHEDULE (TABLA DE DADOS DE CONCRETO)
26-JAN-2022
THICKNESS IN MM
(ESPESOR EN MM)
NO UTILIZADO
0
WIDTH IN MM
(ANCHO EN MM)
2
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
REVISIONES / REVISIONS
LENGTH IN MM
(LONGITUD EN MM)
REFERNCIA DE DADO/MURO O ARREGLO DE ANCLAJE
3
CONCRETE SPREAD FOOTING SCHEDULE (TABLA DE ZAPATA DE CIMENTACION DE CONCRETO)
MARK
(MARCA)
1
IFC (REVIEW)
KEYNOTE LEGEND (LEYENDA DE NOTAS CLAVE)
www.vestalcorporation.com
T: 314.439.9900
F: 314.439.9906
CORPORATION
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
PK APROBO:
DIBUJO:
21023-050000a-S600
DIBUJO NO:
COTAS:
SCHEDULES
(TABLAS)
mm
ESCALA:
1 : 10
IK
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
TITULO DEL PLANO:
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
FIRMA DE DISEÑO / DESIGN FIRM
DIAGEO - EL CHARCON - ELEVATE II PROJECT
PRINTED: 1/28/2022 14:04:42
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
NOTE:
* SEE SECTIONS FOR ADDITIONAL REQUIREMENTS.
(VER SECCIONES PARA INFORMACION ADICIONAL)
.
KEYNOTE LEGEND
650
"P"
PEMB BASE
PLATE
AR-1
1 3/8"Ø
12
3'-0"
55
6"
PB-1
AR-2
1 1/8"Ø
12
3'-0"
55
6"
PB-2
40
NUT & WASHER 47
AR-3
1"Ø
8
2'-2"
55
6"
PB-3
AR-4
1 3/8"Ø
12
3'-0"
55
6"
PB-4
AR-5
1 1/8"Ø
12
3'-0"
55
6"
PB-2
M-7
750
CW300
(12) 1 3/8" Ø ANCHOR
BOLTS
120
260
ANCHOR SETTING PATTERN CORRESPONDS
WITH PRE-ENGINEERED METAL BUILDING (PEMB)
BASE PLATES PB-1
975
..............................
7
..............................
8
..............................
9
..............................
10 ..............................
11 ..............................
51
NOTAS:
1.
COORDINAR TODOS LOS TAMAÑOS, CANTIDADES Y UBICACIONES DE PERNOS DE ANCLAJE CON LOS PLANOS DE LA EDIFICACIÓN DE ACERO DE PRE-INGENIERÍA (PEMB).
2.
CONSULTAR PLANO DE PEMB E-1101 REV_0 CON FECHA DEL 22 DE DICIEMBRE DEL 2021, PARA LA COORDINACIÓN CON LA TABLA DE PERNOS DE ANCLAJE Y DETALLES.
ANCHOR SETTING PATTERN CORRESPONDS
WITH PRE-ENGINEERED METAL BUILDING (PEMB)
BASE PLATES PB-2
ANCHOR SETTING PATTERN AR-2
(ARREGLO DE ANCLAJES AR-2)
2
1 : 20
1 : 20
S100 S601
SEE OVENS FOUNDATION
PACKAGE
M-B
FACE OF PEMB
COLUMN
FACE OF PEMB
COLUMN
1150
650
500
650
125
260
125
TIES, SEE SCHEDULE
(8) 1" Ø ANCHOR BOLTS
P1-M
750
60
120
(12) 1 1/8" Ø ANCHOR BOLTS
M-1
CW300
16
ANCHOR ROD WITH
LEVELING NUT - SIZE PER
TANK MANUFACTURER
16
ANCHOR ROD WITH
LEVELING NUT - SIZE PER
TANK MANUFACTURER
24
ANCHOR ROD WITH
LEVELING NUT - SEE
STEEL PACKAGE
17
40mm MIN. NON SHRINK
GROUT UNDER BASE PLATE
17
40mm MIN. NON SHRINK
GROUT UNDER BASE PLATE
18
25mm THK. EMBED PLATE
A304 SS STAINLESS STEEL
225
19
19
SLOPE
17
40mm MIN. NON SHRINK
GROUT UNDER BASE PLATE
25
51mm THK.A572 GRADE 50
EMBED PLATE
19 SLOPE
9 - #8 A706 REBAR
21
CW300
#4 TIES @ 75mm
LOSA DE CIMENTACIÓN REFUERZO NO SE
MUESTRA POR CLARIDAD
8
FOUNDATION MAT REINFORCEMENT
NOT SHOWN FOR CLARITY
(TYP) (TIPO)
8
600
325
(8) 1" Ø ANCHOR BOLTS
(TYP) (TIPO)
850 N.T.S.
FOUNDATION MAT REINFORCEMENT
NOT SHOWN FOR CLARITY
125 175
CJP ROD TO
EMBED PLATE, 20
TYP
LOSA DE CIMENTACIÓN REFUERZO NO SE
MUESTRA POR CLARIDAD
9 - #8 A706 REBAR
21
(TYP) (TIPO)
8
27
9 - #8 REBAR
#4 TIES
28
29
LENTON ANCHOR 22
270
100
EM-1 EMBED PLATE DETAIL
(DETALLE DE PLACA EMBEBIDA EM-1)
1 : 15
270
270
100
8
S101 S601
50
#4 TIES
100
200
200
29
100
600
740
TYPICAL AT TANK / EQUIPMENT SUPPORTS
TÍPICO EN SOPORTES DE TANQUE / EQUIPO
S101 S601
200
100
740
50mm ⌀ VENT HOLE
100
270
270
50
LOSA DE CIMENTACIÓN REFUERZO NO SE
MUESTRA POR CLARIDAD
100
100
100
7
23
50
740
270
740
1 : 20
50mm ⌀ VENT HOLE
22
100
100
50
23
50
270
50mm ⌀ VENT HOLE
270
50
ANCHOR SETTING PATTERN AR-6
(ARREGLO DE ANCLAJES AR-6)
LENTON ANCHOR
200
22
FOUNDATION MAT REINFORCEMENT
NOT SHOWN FOR CLARITY
600
LENTON ANCHOR
100
850
S100 S601
25mm THK. EMBED PLATE
A304 SS STAINLESS STEEL
SLOPE
CONT. WALL REINF.
THRU PILASTER
ANCHOR SETTING PATTERN CORRESPONDS
WITH PRE-ENGINEERED METAL BUILDING (PEMB)
BASE PLATES PB-3
6
18
CJP ROD TO
EMBED PLATE, 20
TYP
P2-M
550
600
M-1
CJP ROD TO
EMBED PLATE, 20
TYP
TYPICAL AT TANK / EQUIPMENT SUPPORTS
TÍPICO EN SOPORTES DE TANQUE / EQUIPO
TYPICAL AT COLUMNS
TÍPICO EN COLUMNAS
EM-2 EMBED PLATE DETAIL
(DETALLE DE PLACA EMBEBIDA EM-2)
EM-3 EMBED PLATE DETAIL
(DETALLE DE PLACA EMBEBIDA EM-3)
1 : 15
9
S101 S601
1 : 15
23
www.vestalcorporation.com
COLUMN, SEE STEEL PACKAGE
IK
26
PK APROBO:
TANK BASE PLATE SIZE PER TANK
MANUFACTURER
DIBUJO:
4
T: 314.439.9900
F: 314.439.9906
TANK BASE PLATE SIZE PER TANK
MANUFACTURER
21023-050000a-S601
4
As indicated
50
100
1 : 20
ESCALA:
50
100
375
S100 S601
mm
VERT. DOWELS,
SEE SCHEDULE
1 : 20
S100 S601
375
5
DIBUJO NO:
1 : 20
750
TIES, SEE SCHEDULE
4
ANCHOR SETTING PATTERN AR-5
(ARREGLO DE ANCLAJES AR-5)
600
S100 S601
ANCHOR SETTING PATTERN AR-4
(ARREGLO DE ANCLAJES AR-4)
75
3
ANCHOR SETTING PATTERN AR-3
(ARREGLO DE ANCLAJES AR-3)
COTAS:
ANCHOR SETTING PATTERN CORRESPONDS
WITH PRE-ENGINEERED METAL BUILDING (PEMB)
BASE PLATES PB-3
CORPORATION
CONT. WALL REINF.
THRU PILASTER
05 - MILLS BUILDING
00 - GENERAL
00 - GENERAL
030000
CONCRETE
ANCHOR SETTING PATTERN CORRESPONDS
WITH PRE-ENGINEERED METAL BUILDING (PEMB)
BASE PLATES PB-2
FUNCTIONAL AREA:
SUB AREA GROUP:
SUB AREA OR SYSTEM:
CSI CODE:
CSI DESCRIPTION:
ANCHOR SETTING PATTERN CORRESPONDS
WITH PRE-ENGINEERED METAL BUILDING (PEMB)
BASE PLATES PB-4
750
ANCHOR SCHEDULE AND DETAILS
(DETALLES Y TABLA DE ANCLAJES)
CORNER REINF.
PER TYPICAL
DETAILS
375
TITULO DEL PLANO:
(12) 1 3/8" Ø ANCHOR BOLTS
DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779
P2-M
THE PINES OFFICE CENTER
1 THE PINES COURT, SUITE A
CHESTERFIELD, MO 63141
CONT. WALL REINF.
THRU PILASTER
50
100
375
CW300
FIRMA DE DISEÑO / DESIGN FIRM
50
100
120
DIAGEO - EL CHARCON - ELEVATE II PROJECT
TIES, SEE SCHEDULE
260
50
130
60
120
550
M.3 M.5
225
VERT. DOWELS,
SEE SCHEDULE
TIES, SEE SCHEDULE
120
375
175
CW300
325
M-7
50
CONT. WALL REINF.
THRU PILASTER
VERT. DOWELS,
SEE SCHEDULE
50
130
P2-M
VERT. DOWELS,
SEE SCHEDULE
375
600
55
CLIENTE / CLIENT
500
975
1200
1150
375
600
M-B
600
O-8
PRINTED: 1/28/2022 14:04:48
C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected]
6
NOTES:
1.
COORDINATE ALL ANCHOR BOLT SIZE, QUANTITIES AND LOCATIONS WITH PRE-ENGINEERED METAL BUILDING (PEMB) DRAWINGS.
2.
REFERENCE PEMB DRAWING E-1101 REV_0 DATED DEC.22, 2021 FOR COORDINATION WITH ANCHOR BOLT SCHEDULE AND DETAILS.
1150
ANCHOR SETTING PATTERN AR-1
(ARREGLO DE ANCLAJES AR-1)
S100 S601
..............................
(12) 1 1/8" Ø ANCHOR BOLTS
120
850
1
5
REVISIONES / REVISION
P2-M
..............................
P1-M
50
CONT. WALL REINF.
THRU PILASTER
4
FASE DISEÑO / DESIGN PHASE
M.6
51
..............................
CONT. WALL REINF.
THRU PILASTER
375
60
120
M.4
T/NUT
3
ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES
60
120
M.2
NUT 50
TACK
TIES, SEE SCHEDULE
50
130
CW300
VERT. DOWELS,
SEE SCHEDULE
CORNER REINF.
PER TYPICAL
DETAILS
"L"
VERT. DOWELS,
SEE SCHEDULE
TIES, SEE SCHEDULE
..............................
375
125
50
130
260
375
125
"P"
55
LEVELING NUT
48
T/CONC.
49
2
REVISIONES / REVISIONS
500
600
1150
"L"
GRADE
39
26-JAN-2022
O-8
FACE OF PEMB
COLUMN
35
SEE OVENS FOUNDATION
PACKAGE
650
ANCHOR
QUANTITY 38
W, R
E
I
O
EV T F
R
O
,
OR Y - N ION IÓN
F
S
T
UE INAR UC EVI ARA
S
R
R
IS LIM ST A O P - )
N AR N N
E
PR CO O P AR - CIÓ
D
ITI IMIN RUC
M
(E REL NST
P CO
FECHA / DATE
500
ANCHOR
SIZE
37
ANCHOR
MARK
ANCHOR SCHEDULE - PEMB BUILDING COLUMNS
13
(MIN)
M-B
1150
..............................
0
36
FACE OF PEMB
COLUMN
1
IFC (REVIEW)
M-B