26-JAN-2022 0 www.vestalcorporation.com T: 314.439.9900 F: 314.439.9906 CORPORATION IK PK APROBO: DIBUJO: KEY PLAN (PLANO CLAVE) 21023-050000a-S001 TRUE NORTH ESCALA: F mm M DIBUJO NO: A COTAS: PROJECT LOCATION (UBICACIÓN DEL PROYECTO) THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 HOJA DE PORTADA / VISTA EN 3D NOTAS GENERALES NOTAS GENERALES PLANO DE CIMENTACIÓN - MOLIENDA PLANTA DE ARREGLO DE ANCLAJES ELEVACIONES DE CIMENTACIÓN CIMENTACION SECCIONES Y DETALLES DETALLES TÍPICOS DETALLES TÍPICOS TABLAS DETALLES Y TABLA DE ANCLAJES COVER SHEET / 3D VIEW (HOJA DE PORTADA / VISTA EN 3D) COVER SHEET / 3D VIEW GENERAL NOTES GENERAL NOTES FOUNDATION PLAN - MILLS ANCHOR LAYOUT PLAN FOUNDATION ELEVATIONS FOUNDATION SECTIONS AND DETAILS TYPICAL DETAILS TYPICAL DETAILS SCHEDULES ANCHOR SCHEDULE AND DETAILS NOMBRE DE DIBUJO 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE 0 0 0 0 0 0 0 0 0 0 0 DRAWING NAME FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: STRUCTURAL 21023-050000a-S001 21023-050000a-S002 21023-050000a-S003 21023-050000a-S100 21023-050000a-S101 21023-050000a-S200 21023-050000a-S300 21023-050000a-S500 21023-050000a-S501 21023-050000a-S600 21023-050000a-S601 REV TITULO DEL PLANO: NO. DE PLANO (SHEET NUMBER) ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES LISTA DE DIBUJOS (LIST OF DRAWINGS) - CIMENTACIÓNES (FOUNDATION) DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 PRINTED: 1/28/2022 14:04:27 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] S001 DIAGEO - EL CHARCON - ELEVATE II PROJECT 1 3D VIEW FOUNDATION (CIMENTACIÓN VISTA EN 3D) FIRMA DE DISEÑO / DESIGN FIRM CLIENTE / CLIENT FASE DISEÑO / DESIGN PHASE REVISIONES / REVISION REVISIONES / REVISIONS FECHA / DATE DR - ST.05.00.00.a - MILLS BUILDING - FOUNDATIONS DR - ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES IFC (REVIEW) DIAGEO - EL CHARCON - ELEVATE II PROJECT W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO . ALL OFFSITE BORROW MATERIAL MUST BE FROM A LICENSED AND OWNER-APPROVED SITE. 14. ALL EXCAVATION SOILS SHALL BE TESTED BY THE OWNER PRIOR TO REMOVAL FROM THE SITE. THE DETAILING, FABRICATION, AND ERECTION OF ALL STRUCTURES SHALL CONFORM TO THE CODES LISTED BELOW. (LATEST EDITIONS SHALL BE USED UNLESS SPECIFIED). 5. ALL REINFORCING SHALL BE SUPPORTED IN FORMS, SPACED WITH NECESSARY ACCESSORIES AND SHALL BE SECURELY WIRED TOGETHER, IN ACCORDANCE WITH ACI 318. 6. MINIMUM CONCRETE COVER FOR THE REINFORCEMENT SHALL BE AS DETAILED ON THE DRAWINGS. WHERE THE COVER IS NOT DIMENSIONED, USE PROVISIONS OF ACI 318. 7. DEVELOPMENT OF REINFORCEMENT AND LAP SPLICES SHALL BE IN ACCORDANCE WITH ACI 318 ALL SPLICES SHALL BE CLASS "B" TYPE. 8. MECHANICAL SPLICES SHALL BE IN ACCORDANCE WITH ACI 318 AND DEVELOP AT LEAST 125 PERCENT OF THE SPECIFIED YIELD STRESS OF THE BAR. 9. ALL MAIN VERTICAL AND HORIZONTAL REINFORCING STEEL EXCLUDING TIES AND STIRRUPS, SHALL BE MECHANICALLY SPLICED OR LAPPED PER SCHEDULE ON TYPICAL DETAILS SHEET. ALL CONCRETE SHALL HAVE A MINIMUM DENSITY OF 150 PCF AND A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS AS FOLLOWS: A. 300kg/cm2 FOUNDATION AND SLAB ON GRADE. B. 250kg/cm2 SLAB ON COMPOSITE DECK. C. 100kg/cm2 MUD SLAB. 2. BEFORE PLACING CONCRETE, COORDINATE WITH MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTOR FOR BLOCKOUTS AND EMBEDDED ITEMS NOT SHOWN ON STRUCTURAL DRAWINGS. 3. EXPOSED EDGES OF CONCRETE ABOVE GRADE SHALL HAVE 20 MM x 45 DEGREE CHAMFERS, UNLESS NOTED OTHERWISE (U.N.O.) 4. ALL CONTROL JOINTS IN SLAB-ON-GRADE SHALL BE SAWN WITHIN 12 HOURS OF CONCRETE PLACEMENT WITHOUT RAVELING THE JOINTS. 5. ANCHOR RODS SHALL BE ASTM F1554 (Fy=2500 kg/cm2 (36 ksi)) RODS, U.N.O. ALL ANCHOR ROD PROJECTIONS NOTED OR SHOWN ON THE DRAWINGS SHALL BE MEASURED FROM THE TOP OF THE ROUGH CONCRETE AND NOT SET FROM THE GROUT. INTERNATIONAL BUILDING CODE, IBC 2018 EDITION. 6. BASE PLATES AND ANCHOR RODS BELOW GRADE SHALL BE COVERED WITH A MINIMUM OF 75MM OF CONCRETE. 3. ASCE 7-16 "MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES". 7. 4. ACI 301 "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS". PROVIDE STANDARD HOOKS ON BARS TERMINATING AT A CONCRETE FACE UNLESS NOTED (E.G.: EDGES OF OPENINGS, SLAB EDGES, EXPANSION JOINTS, ENDS OF BEAMS, AND AT TOP, BOTTOM, AND ENDS OF WALLS, ETC.). 5. ACI 318-14 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". 8. 6. AISC 360-16 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS". 7. AISC 303-16 "CODE OF STANDARD PRACTICE FOR BUILDINGS AND BRIDGES". ALL CONSTRUCTION JOINTS SHOWN ON DRAWINGS SHALL BE INCORPORATED INTO THE STRUCTURE, UNLESS THEIR ELIMINATION IS APPROVED BY THE STRUCTURAL ENGINEER. ADDITIONAL CONSTRUCTION JOINTS, REQUIRED TO FACILITATE CONSTRUCTION, SHALL BE LOCATED AT POINTS OF MINIMUM SHEAR, AND SHALL BE DETAILED ON SHOP DRAWINGS. REINFORCEMENT SHALL PASS CONTINUOUSLY THROUGH THE JOINT. 8. ANSI/AWS D1.1 "STRUCTURAL WELDING CODE - STEEL", D1.4 "STRUCTURAL WELDING CODE - REINFORCING STEEL" AND D1.3 "STRUCTURAL WELDING CODE - SHEET STEEL". NORMAS TECNICAS COMPLEMENTARIA ESTRUCTURALES DE LA LEY DE EDIFICACIONES DEL ESTADO DE JALISCO. SPECIAL INSPECTION 1. SPECIAL INSPECTION SHALL BE IN ACCORDANCE WITH THE BUILDING CODE 2. SPECIAL INSPECTION REPORT SHALL BE AS INDICATED ON THE TESTING, INSPECTION, OBSERVATION PROGRAM APPROVED BY OWNER 3. BUILDING CLASSIFICATION PER IBC-2018 1. RISK CATEGORY II. STRUCTURAL LOADS 1. NO PROVISIONS HAVE BEEN MADE FOR FUTURE VERTICAL EXPANSION. FOUNDATIONS HAVE BEEN DESIGNED FOR FUTURE HORIZONTAL EXPANSION TO THE WEST. 2. GRAVITY LOADS: DEAD LOAD -SELF WEIGHT OF STRUCTURE AND ELEMENTS INCORPORATED INTO CONSTRUCTION DRAWINGS -TYPICAL COLLATERAL LOAD (MECHANICAL,ELECTRICAL,PLUMBING): 15kg/m2 -FIRE PIPING: 5 kg/m2 LIVE LOADS - OFFICE LIVE LOAD: 250kg/m2 - CORRIDOR LIVE LOAD: 400kg/m2 - STAIR LIVE LOAD: 500kg/m2 - LIGHT STORAGE LIVE LOAD: 625kg/m2 - HEAVY STORAGE LIVE LOAD: 1250kg/m2 - ROOF LIVE LOAD (REDUCIBLE PER ASCE 7-16): 100kg/m2 3. WIND LOAD DESIGN PARAMETERS PER ASCE 7-16 (AND FM GLOBAL 1-28): - BASIC WIND SPEED – 190 KM/H (115 MPH) - EXPOSURE CATEGORY – C 4. SEISMIC DESIGN PARAMETERS: A. PROCEDURE OUTLINED IN IBC-2018 (ASCE 7-16) WITH THE FOLLOWING DESIGN PARAMETERS: - RISK IMPORTANCE FACTOR : I=1.0 - SITE CLASS = C - DESIGN SPECTRAL ACCELERATIONS PER SITE SPECIFIC SEISMIC STUDY: - SDS =0.23G - SEISMIC DESIGN CATEGORY: B - SEISMIC FORCE RESISTING SYSTEMS: "STEEL SYSTEM NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE" (R=3, Ω=3, Cd=3) B. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE WELDED CONNECTIONS SHALL BE IN ACCORDANCE WITH AWS D1.1 "STRUCTURAL WELDING CODE." WELDING ELECTRODES SHALL BE E70XX. 6. SPLICING OF STEEL MEMBERS, UNLESS SHOWN ON DRAWINGS, IS PROHIBITED. 7. NO CHANGE IN SIZE OR POSITION OF THE STRUCTURAL ELEMENTS SHALL BE MADE AND HOLES, SLOTS, CUTS, ETC. ARE NOT PERMITTED THROUGH ANY MEMBER UNLESS THEY ARE DETAILED ON THE APPROVED SHOP DRAWINGS. 8. NO FINAL BOLTING OR WELDING SHALL BE MADE UNTIL THE STRUCTURE HAS BEEN PROPERLY ALIGNED. 9. NO BEAM OR BRACE CONNECTION SHALL HAVE LESS THAN TWO (2) BOLTS OR AN EQUIVALENT WELD. 10. CORROSION PROTECTION: PAINTING OF STRUCTURAL STEEL (OR GALVANIZING WHERE APPLICABLE) IS REQUIRED FOR ANY EXPOSED STEEL. 11. FOR CORROSION PROTECTION: SEE STRUCTURAL STEEL SPECIFICATION SECTION 051200. 12. BOLTS IN BOLTED CONNECTIONS DESIGNATED AS PRETENSIONED JOINTS SHALL BE INSTALLED WITH TENSION CONTROL BOLTS (ASTM F3125/F3125M). 13. PRETENSIONED JOINTS ARE REQUIRED AT THE FOLLOWING LOCATIONS WHEN BOLTED CONNECTIONS ARE INDICATED: A. MOMENT FRAME CONNECTIONS B. CONNECTIONS OF BEAMS BEARING ON COLUMN CAP PLATES C. DRAG BEAM CONNECTIONS D. HANGERS E. CONNECTIONS OF BEAMS THAT ARE PART OF THE VERTICAL BRACING SYSTEM F. ELEVATOR MACHINE BEAMS G. SPECIAL CONNECTIONS AS INDICATED ON THE DRAWINGS CONCRETE 1. 2. 9. 5. COLD - FORMED STEEL FRAMING 1. ASTM A653/ A653 M, GRADE 50 Fy= 3500 kg/cm2. 2. COLD-FORMED METAL FRAMING SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH AISI'S "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS," 2010. 3. FULL-HEIGHT DOUBLE STUDS SHALL BE PROVIDED AT THE ENDS OF PARTITIONS AND AT WALL OPENINGS UNLESS NOTED OTHERWISE ON DRAWINGS. 4. FULL-HEIGHT DOUBLE STUDS SHALL BE PROVIDED AT OTHER LOCATIONS INDICATED IN THE STRUCTURAL DRAWINGS. A. WELD THE FLANGES OF DOUBLE STUDS TOGETHER FULL HEIGHT USING 50mm OF WELD AT 300mm C.C. EACH SIDE. 5. ANCHOR TRACKS OF INTERIOR STUD WALLS WITH LOW-VELOCITY (TYPE X-U) POWDER ACTUATED FASTENERS WITH A MINIMUM SHANK DIAMETER OF 4mm, AND A MINIMUM PENETRATION OF 32mm. LOCATE ANCHORS 75mm FROM THE ENDS OF PARTITIONS, AND AT 400mm C.C. (MAX.) THROUGHOUT FOR INTERIOR PARTITIONS UNLESS NOTED OTHERWISE (U.N.O). REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS. 6. PROVIDE VERTICAL DEFLECTION CLIPS/SLIP DEVICES AT TOP OF STUDS AS SHOWN ON DRAWINGS. 7. PROVIDE STUD WALL BRIDGING ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 8. SPLICES IN STUDS SHALL NOT BE PERMITTED. DO NOT CUT STUDS. 9. AT LOCATIONS REQUIRING WELDING OF OR TO METAL STUDS, MINIMUM STUD THICKNESS SHALL BE 43 MIL. 10. THE NOMINAL WELD FOR FILLET WELD OR FLARE GROOVE WELD SHALL BE AS FOLLOWS (UNLESS NOTED OTHERWISE): STEEL THICKNESS (MILS) WELD SIZE 43 1/16” (1.6 mm) 54 3/32” (2.4 mm) 68 AND LARGER 1/8” (3.2 mm) 11. PROVIDE TRACK AT TOP AND BOTTOM OF STUD WALLS AND AT HEADERS AND SILLS FOR STUD WALLS, THICKNESS OF TRACK TO MATCH THICKNESS OF STUD. 12. TRACK THAT IS USED FOR JAMBS, HEADERS AND SILLS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE MEMBER. NO SPLICES ARE ALLOWED. THE FOLLOWING TYPES OF WORK REQUIRE SPECIAL INSPECTIONS: (REFER TO THE BUILDING CODE AND SPECIFICATIONS FOR DETAILED INSPECTION REQUIREMENTS A. PREPARED FILL AND BEARING CAPACITY FOR SHALLOW FOUNDATIONS B. PLACEMENT OF CONCRETE C. CAST-IN PLACE AND POST-INSTALLED ANCHORS IN CONCRETE D. SPECIAL INSERTS, STUD RAILS, REBAR MECHANICAL CONNECTION, HEADED REBARS E. REINFORCING STEEL F. WELDING OF REINFORCING REBARS G. AUTOMATIC AND END-WELDED STUDS H. WELDING I. STEEL FRAMING www.vestalcorporation.com THE STRUCTURE, INCLUDING THE FOLLOWING SYSTEMS BUT NOT LIMITED TO: STEEL MOMENT FRAMES, STEEL BRACED FRAMES, CAST-IN-PLACE CONCRETE SLABS, AND STEEL ROOF DECK DIAPHRAGM, IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES SHALL BE DESIGNED AND FURNISHED BY CONTRACTOR. REFERENCES PRINTED: 1/28/2022 14:04:28 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] ALL REINFORCING BARS SHALL BE DETAILED, FABRICATED, SUPPORTED AND PLACED IN ACCORDANCE WITH ACI 315-99 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" AND CRSI "MANUAL OF STANDARD PRACTICE" 2008. NO CHANGE IN SIZE OR DIMENSION OF STRUCTURAL MEMBERS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE OWNER'S REPRESENTATIVE. 13. 1. 4. IK 12. BOLTED CONNECTIONS SHALL BE BEARING TYPE USING A325N BOLTS, UNLESS NOTED OTHERWISE. OVERSIZED HOLES AND LONG-SLOTTED HOLES ARE NOT ALLOWED, UNLESS SHOWN ON THE DRAWINGS. PK APROBO: 11. 4. DIBUJO: NO PIPES, DUCTS, CHASES ETC. SHALL BE PLACED IN STRUCTURAL BEAM AND COLUMN MEMBER NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS NOTED OTHERWISE. NOTIFY STRUCTURAL ENGINEER WHEN DOCUMENTS BY OTHER DISCIPLINES SHOW OPENINGS, SLEEVES, POCKETS, ETC. NOT INDICATED ON STRUCTURAL DRAWINGS, BUT ARE LOCATED IN STRUCTURAL MEMBERS. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR STRUCTURAL ENGINEER FOR INSTALLATION OF SUCH PIPES, DUCTS, CHASES, ETC. ALL REINFORCING STEEL, ANCHOR RODS, DOWELS, INSERTS, ETC. SHALL BE WELL SECURED IN PLACE AND INSPECTED BY OWNER'S REPRESENTATIVE PRIOR TO PLACING CONCRETE. T: 314.439.9900 F: 314.439.9906 10. 3. 21023-050000a-S002 DO NOT SCALE THESE DRAWINGS - USE DIMENSIONS REINFORCING STEEL TO BE WELDED OR AS SPECIFICALLY NOTED SHALL BE ASTM A706 DEFORMED BARS. 1 : 10 9. 2. ESCALA: INFORM THE OWNER'S REPRESENTATIVE IN WRITING OF ANY DEVIATION FROM THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY OF SUCH DEVIATION BY THE OWNER'S REPRESENTATIVE REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC., UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED THE OWNER'S REPRESENTATIVE OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE OWNER'S REPRESENTATIVE HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEVIATION. UNLESS NOTED OTHERWISE, THE MINIMUM PLATE THICKNESS SHALL BE 10MM; MINIMUM BOLT DIAMETER SHALL BE 19MM; MINIMUM WELD SHALL BE 5MM. mm 8. COORDINATE THE LOCATIONS AND SIZES OF ALL OPENINGS IN CAST-IN-PLACE WALLS AND FLOORS, AND LOCATIONS OF COMPONENTS REQUIRED TO BE EMBEDDED IN THE CONCRETE, WITH THE ARCHITECTURAL DRAWINGS AND PLUMBING, MECHANICAL, AND ELECTRICAL REQUIREMENTS. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A-615, GR 60, U.N.O. DIBUJO NO: 7. DETAILS ENTITLED OR NOTED AS TYPICAL SHALL APPLY NOT ONLY WHERE SPECIFICALLY INDICATED OR REFERENCED, BUT WHERE THE NATURE OF THE CONSTRUCTION REQUIRES THEIR USE. 1. COTAS: 6. 3. REINFORCEMENT CORPORATION OPENINGS FOR CONDUIT, PIPE BANKS, ETC., NOT SHOWN ON STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. ADDITIONAL STRUCTURAL REINFORCEMENT AND CLOSURES FOR FLOOR AND WALL SHALL BE PROVIDED. ALL STRUCTURAL STEEL SHALL BE DETAILED FABRICATED AND ERECTED IN ACCORDANCE WITH AISC "CODE OF STANDARD PRACTICE". THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 5. 2. GENERAL NOTES (NOTAS GENERALES) VERIFY THE COORDINATION OF ALL TRADES AND REPORT ANY CONFLICTS IMMEDIATELY TO THE OWNER'S REPRESENTATIVE. 26-JAN-2022 4. 0 EXCAVATIONS SHALL BE KEPT FREE OF LOOSE MATERIAL AND STANDING WATER. IFC (REVIEW) 3. 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE SPECIFIC DETAILS AND NOTES TAKE PRECEDENCE OVER STANDARD DETAILS AND NOTES. WHERE CONFLICTS EXIST BETWEEN THE DRAWINGS, THE SPECIFICATIONS, AND THE GENERAL STRUCTURAL NOTES, THE STRICTEST PROVISION SHALL GOVERN. A992 (Fy=3500 KG/CM2) A36 (Fy=2500 KG/CM2) A36 (Fy=2500 KG/CM2) A53 GRB (Fy=2450 KG/CM2) A500 GRB (Fy=3200 KG/CM2) A500 GRB (Fy=2950 KG/CM2) FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: 3. A. ALL W AND WT SHAPES B. ALL ANGLE, CHANNEL C. ALL BASE PLATES, CONN. PLATES D. STRUCTURAL PIPE E. STRUCTURAL TUBE F. HSS ROUND SHAPE TITULO DEL PLANO: OWNERS'S GEOTECHNICAL REPRESENTATIVE SHALL CERTIFY THE BEARING MEDIUM PRIOR TO CONCRETE PLACEMENT. FECHA / DATE 2. REVISIONES / REVISION VERIFY ALL DIMENSIONS BEFORE STARTING WORK AND NOTIFY THE OWNER'S REPRESENTATIVE IMMEDIATELY OF ANY DISCREPANCIES FOUND. STEEL SHALL CONFORM TO THE FOLLOWING GRADES: FASE DISEÑO / DESIGN PHASE 2. 1. ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES THE FOUNDATION HAS BEEN DESIGNED IN ACCORDANCE WITH GEOTECHNICAL REPORT BY LAINCO LABORATORIOS DATED TITLED "REPORT OF GEOTECHNICAL RESEARCH" DATED OCTOBER 15TH, 2021. DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 1. REVISIONES / REVISIONS IN MOST CASES THE CRITERIA FOR THE STRUCTURE IS ESTABLISHED ON THE DRAWINGS AND IN THE SPECIFICATIONS. WHERE IT IS NOT, THESE NOTES SHALL GOVERN. CLIENTE / CLIENT 1. STRUCTURAL STEEL FIRMA DE DISEÑO / DESIGN FIRM FOUNDATION EXCAVATION AND BACKFILL GENERAL NOTES DIAGEO - EL CHARCON - ELEVATE II PROJECT STRUCTURAL GENERAL NOTES W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO . 10. TODO EL ACERO ESTRUCTURAL EXPUESTO DEBERA CONTAR CON UN ANTICORROSIVO Y PINTURA, EXCEPTO EN AQUELLOS CASOS DONDE LA ESTRUCTURA SEA GALVANIZADA. A. B. C. 9. NO SE DEBERAN TOMAR MEDIDAS A ESCALA, LAS COTAS RIGEN AL DIBUJO. 10. NO SE PERMITE INSTALAR TUBERIAS, DUCTOS, EN LAS COLUMNAS O VIGAS ESTRUCTURALES , NI REALIZAR HUECOS O CORTAR NINGUNO DE LOS ELEMENTOS ESTRUCTURALES PARA TUBERIAS O DUCTOS A EXCEPCION DONDE SE INDIQUE. SE DEBERA NOTIFICAL AL INGENIERO EN ESTRUCTURAS CUANDO LOS DOCUMENTOS DE OTRAS DISCIPLINAS INDIQUEN EN LOS ELEMENTOS ESTRUCTURALES HUECOS, CAMISAS PARA PASO U OQUEDADES NO MOSTRADOS EN LOS PLANOS ESTRUCTURALES. EL CONTRATISTA DEBERA CONTAR CON LA APROBACION DEL INGENIERO EN ESTRUCTURAS PREVIO A CUALQUIER INSTALACION DE TUBERIAS, DUCTOS EN CUALQUIER ELEMENTO ESTRUCTURAL. 300kg/cm2 - CIMENTACIÓN LOSAS DE PISO 250kg/cm2 - LOSAS DE ENTREPISO (EN LOSACERO) 100kg/cm2 - HORMIGON 11. PARA PROTECCION POR CORROSION: VER ESPECIFICACION DE ACERO ESTRUCTURAL SECCION 051200 2. ANTES DE COLOCAR EL CONCRETO SE DEBERA DE COORDINAR CON LAS DISCIPLINAS MECÁNICA, ELECTRICA E INSTALACIONES HIDRAULICAS Y SANITARIAS, POR CUALQUIER HUECO O ELEMENTOS EMBEBIDOS NECESARIOS Y QUE NO SE MUESTRE EN LOS PLANOS ESTRUCTURALES. 3. LOS BORDES EXPUESTOS DE CONCRETO POR ENCIMA DEL NIVEL DE PISO TERMINADO TENDRÁN UN CHAFLAN DE 20 MM, A MENOS QUE SE INDIQUE LO CONTRARIO. 11. CUALQUIER CAMBIO EN TAMAÑO O DIMENSION DE LOS ELEMENTOS ESTRUCTURALES DEBERA DE CONTAR CON EL CONSENTIMIENTO POR ESCRITO DEL REPRESENTANTE DEL PROPIETARIO. 4. TODAS LAS JUNTAS DE CONTRACCION EN LAS LOSA DE PISOS SE DEBERAN DE CORTAR ANTES DE 12 HORAS DE TERMINADO EL COLOCADO, PERO SIN EL DESPORTILLAMIENTO DE LAS JUNTAS. 12. LA ESTRUCTURA INCLUYE LOS SIGUIENTES SISTEMAS.(DE FORMA NO EXCLUYENTE): ESTRUCTURA METALICA A BASE DE MARCOS RIGIDOS, MARCOS CONTRAVENDEADOS, LOSAS DE CONCRETO COLADAS EN SITIO, Y CUBIERTAS METALICAS, LAS CUALES SE HAN DISEÑADO PARA TRABAJAR COMO UNA SOLA UNIDAD UNA VEZ CONCLUIDOS LOS TRABAJOS. CUALQUIER ARRIOSTRAMIENTO Y/O SOPORTE TEMPORAL QUE SE REQUIERA COMO EL RESULTADO DE METODOS Y/O SECUENCIAS DE CONSTRUCCIÓN DEL CONTRATISTA SERÁN DISEÑADAS Y SUMINISTRADAS POR EL CONTRATISTA . 5. LAS ANCLAS SERÁN ASTM F1554 (Fy = 2500KG/CM2 (36 ksi)) BARRAS, EXCEPTO SE INDIQUE OTRA COSA. TODAS LAS PROYECCIONES DEL ANCLAJE INDICADAS EN LOS PLANOS SE MEDIRÁN DEL TOPE DEL CONCRETO, Y NO DEL GROUT. 6. LAS PLACAS BASE Y ANCLAS QUE SE ENCUENTREN POR DEBAJO DEL NIVEL DE PISO TERMINADO DEBERAN DE QUEDAR EMBEBIDAS DE CONCRETO CON UN MÍNIMO DE 75MM. TODO EL MATERIAL DE RELLENO QUE PROVENGA FUERA DE LA OBRA DEBE PROVENIR DE UN SITIO CON LICENCIA, QUE CUMPLA CON LAS ESPECIFICACIONES Y APROBADO POR EL PROPIETARIO. 7. A MENOS DE QUE SE INDIQUE OTRA COSA EN PLANOS; EN LOS REMATES EN HUECOS, EN LAS ORILLAS DE LAS LOSAS, EN LA TERMINACION DE LOS MUROS, EN HUECOS, EN LOS EXTRMEOS DE LAS VIGAS Y COLUMNAS, TODAS LAS VARILLAS SE DEBERAN DE ANCLAR POR MEDIO DE GANCHOS ESTANDAR EN SUS EXTREMOS. 13. 14. TODO EL MATERIAL DE LA EXCAVACIÓN SERA EXAMINADO POR EL PROPIETARIO ANTES DE RETIRARLO DEL SITIO REFERENCIAS 1. TODAS LAS ESTRUCTURAS SE DETALLARAN, FABRICARAN Y MONTARAN CONFORME A LA ULTIMA REVISION DE LOS CODIGOS ENLISTADOS A CONTINUACION, A MENOS DE QUE SE ESPECIFIQUE OTRA COSA EN PLANOS. 2. CODIGO INTERNACIONAL DE CONSTRUCCION. IBC EDICION 2018. 8. TODAS LAS JUNTAS DE CONSTRUCCION SE DEBERAN DE REALIZAR COMO SE INDICA EN LOS PLANOS, A MENOS DE QUE SU ELIMINACION SEA APROBADA POR EL INGENIERO ESTRUCTURAL. SE PODRAN ADICIONAR JUNTAS DE CONSTRUCCION DURANTE EL PROCESO DE LA OBRA, SIN EMBARGO ESTAS SE DEBERÁN DE LOCALIZAR EN LOS PUNTOS DONDE SE TENGA EL CORTANTE MÍNIMO. EN ESTOS CASOS SE DEBEN DE DETALLAR E INTEGRAR EN LOS PLANOS, EL REFUERZO DEBERÁ SER CONTINUO A TRAVÉS DE LA JUNTA PRINTED: 1/28/2022 14:04:29 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] INSPECCIONES ESPECIALES 3. ASCE 7-16 “CARGAS DE DISEÑO MÍNIMAS PARA EDIFICIOS Y OTRAS CONSTRUCCIONES”. 4. ACI 301 “ESPECIFICACIONES PARA CONCRETO ESTRUCTURAL DE EDIFICIOS’’. 5. ACI 318-14 "REQUISITOS DE CONSTRUCCIÓN DE CONCRETO ARMADO" . 6. AISC 360-16 “ESPECIFICACIONES PARA EDIFICIOS DE ACERO ESTRUCTURAL”. 7. AISC 303-16 “CÓDIGO DE PRÁCTICAS ESTANDARES PARA EDIFICIOS Y PUENTES”. 8. ANSI / AWS D1.1 "CÓDIGO DE SOLDADURA ESTRUCTURAL- ACERO", AWS D1.4 CODIGO DE SOLDADURA ESTRUCTURAL - ACERO DE REFUERZO", Y D1.3 "CÓDIGO DE SOLDADURA ESTRUCTURAL- ACERO EN PLACA”. 9. NORMAS TECNICAS COMPLEMENTARIA ESTRUCTURALES DE LA LEY DE EDIFICACIONES DEL ESTADO DE JALISCO. CLASIFICACIÓN DEL EDIFICIO DE ACUERDO A LA IBC-2018 1. 1. LAS INSPECCIONES ESPECIALES DEBEN SER DE ACUERDO AL CÓDIGO O REGLAMENTOS DE CONSTRUCCION. 2. LOS INFORMES DE LAS INSPECCIONES ESPECIALES DEBEN SER SEGÚN LO ESTABLECIDO EN EL PROGRAMA DE PRUEBAS INSPECCIONES/OBSERVACIÓN APROBADO POR EL PROPIETARIO O SU REPRESENTANTE. 3. LOS SIGUIENTES TRABAJOS REQUIEREN DE UNA INSPECCION DETALLADA Y ESTARA CONFORME A CODIGOS, NORMAS Y ESPECIFICACIONES TÉCNICAS. A. B. C. D. E. F. G. H. I. MATERIAL DE RELLENO COLADO DE CONCRETO. ANCLAS EN CONCRETO FRESCO Y ANCLAS INSTALADAS POSTERIORES AL COLADO. INSERTOS ESPECIALES, PERNOS DE ANCLAJE, EMPALME MECÁNICO EN EL ACERO DE REFUERZO, ANCLAJES MECANICOS EN EXTREMO DEL ACERO DE REFUERZO. ACERO DE REFUERZO EN GENERAL. SOLDADURA DE BARRAS DE REFUERZO. PERNOS SOLDADOS AUTOMÁTICAMENTE Y LOS PERNOS CON SOLDADURA EN EL EXTREMO. SOLDADURA MARCOS ESTRUCTURALES ACERO 12. TORNILLOS EN CONEXIONES ATORNILLADAS, DESIGNADAS COMO JUNTAS PRETENSIONADAS, DEBERAN SER INSTALADAS CON TORNILLOS DE TENSION CONTROLADA (ASTM F3125/F3125M) 13. JUNTAS PRE-TENSIONADAS SERÁN REQUERIDAS EN LAS SIGUIENTES UBICACIONES DONDE LAS CONEXIONES ATORNILLADAS SEAN INDICADAS: A. MOMENTO EN CONEXIONES DE MARCO B. CONEXIONES EN TRABES DE SOPORTE EN PLACAS SOBRE COLUMNAS C. CONEXIONES EN VIGAS DE ARRASTRE D. GANCHOS E. CONEXIONES DE TRABES QUE SON PARTE DE UN SISTEMA VERTICAL DE CONTRAVENTEOS F. TRABES DE MAQUINARIA DE ELEVADORES G. CONEXIONES ESPECIALES TAL COMO SE INDICA EN EL PLANO MARCOS DE ACERO FORMADO EN FRÍO 1. ASTM A653/653 M, GRADO 50, Fy= 3500 kg/cm2 2. LOS MARCOS DE PERFILES ROLADOS EN FRIO DEBERAN DE DISEÑARSE, FABRICARSE Y MONTARSE DE ACUERDO A LO SIGUIENTE: ESPECIFICACION NORTE AMERICANA PARA EL DISEÑO DE PERFILES ESTRUCTURALES ROLADOS EN FRIO. AISI 2007 3. EN LOS EXTREMOS DE LAS DIVISIONES Y EN LAS ABERTURAS PARA MUROS SE DEBERA DE COLOCAR POSTES DOBLES EN TODA LA ALTURA, EXCEPTO SE INDIQUE OTRA COSA EN LOS PLANOS 4. SE COLOCARAN POSTES DOBLES EN AQUELLOS LUGARES QUE INDIQUEN LOS PLANOS ESTRUCTURALES A. LOS POSTES DOBLES SE SOLDARAN EN LOS PATINES MEDIANTE SOLDADURA DE 50 MM SEPARADAS A CADA 300 mm, A CADA LADO DE LOS POSTES. 5. LOS PERFILES HORIZONTALES DE DESPLANTE DONDE SE SOPORTARAN LOS POSTES EN PAREDES INTERIORES DEBERA SER MEDIANTE ANCLAJES DE BAJA VELOCIDAD (TIPO X-U) DE DIAMETRO MINIMO DE 0.157 PULGADAS (4.0 mm) Y CON UNA PENETRACION MINIMA DE 1-1/4 PULGADA (32 mm). LA LOCALIZACION DE LOS ANCLAJES SERA DE 3”(76mm) DESDE LOS EXTREMOS DE LAS DIVISIONES Y POSTERIOMENTE DEBERAN DE QUEDAR ESPACIADOS A CADA 16 PULGADAS ( 400mm) COMO MAXIMO EN TODAS LAS DIVISIONES INTERIORES, EXCEPTO SE INDIQUE OTRA COSA (U.N.O.). VER PLANOS ARQUITECTONICOS PARA DETALLES. 6. INSTALAR ANGULOS DE LAMINA (CLIP/SLIP) QUE PERMITAN EL DESPLAZAMIENTO VERTICAL EN EL EXTREMO SUPERIOR DE LOS POSTES COMO SE INDICA EN LOS DIBUJOS. 7. INSTALAR PERFILES HORIZONTALES PARA ARRIOSTRAR LOS POSTES EN PAREDES CONFORME A LAS RECOMENDACIONES DE LOS FABRICANTES. 8. NO SE PERMITE EL EMPALME DE LOS POSTE. NO SE DEBRAN CORTAR. 9. EN LOS LUGARES QUE REQUIERAN SOLDAR A LOS POSTES O DESDE ELLOS, EL ESPESOR MINIMO DEBERA DE SER DE 43 MIL 10. LA SOLDADURA DE FILETE NOMINAL O SOLDADURA DE RANURA DEBERA SER COMO SE INDICA A CONTINUACION (EXCEPTO SE INDIQUE OTRA COSA) ESPESOR DE ACERO (MILS) TAMAÑO FILETE CATEGORÍA DE RIESGO II. 43 54 68 Y MAYORES CARGAS ESTRUCTURALES 1. 2. NO SE HA CONSIDERADO NINGUN ELEMENTO ADICIONAL PARA CUALQUIER EXPANSION VERTICAL. LAS CIMENTACIONES HAN SIDO DISEÑADAS PARA UNA FUTURA EXPANSION HORIZONTAL HACIA EL OESTE. CARGAS GRAVITACIONALES: CARGA MUERTA - PESO PROPIO DE LA ESTROCTURA Y ELEMENTOS INCORPORADOS EN LOS PLANOS DE CONSTRUCCION - CARGA MUERTA COLATERAL TÍPICA (MECÁNICO, ELÉCTRICO, PLOMERÍA): 15 KG/M2 - TUBERÍA CONTRA INCENDIO: 5 KG/M2 CARGA VIVA - CARGA VIVA EN OFICINA: - CARGA VIVA EN CORREDOR: - CARGA VIVA EN ESCALERAS: - CARGA VIVA PARA ALMACENAMENTO LIGERO: - CARGA VIVA PARA ALMACENAMENTO PESADO: - CARGA VIVA EN TECHOS (REDUCIBLE POR ASCE 7-16): 250 KG/M2 400 KG/M2 500 KG/M2 625 KG/M2 1250 KG/M2 100 KG/M2 3. LAS CARGAS DE VIENTO PARA DISEÑO SON CONFORME AL ASCE 7-16 (Y LAS RECOMENDACIONES DE FM GLOBAL 1-28): - VELOCIDAD BASICA DE VIENTO – 190 KM/H (115 MPH) - CATEGORIA DE EXPOSICION – C 4. PARAMETROS DE DISEÑO SISMICO: A. EL PROCEDIMIENTO ES COMO SE INDICA EN IBC-2018 (ASCE 7-16) CON LOS SIGUIENTES PARAMETROS DE DISEÑ0: - FACTOR DE IMPORTANCIA CONFORME A EL RIESGO: I=1.0 - CLASIFICACION DE SITIO-C - ACELERACIONES ESPECTRALES DE DISEÑO POR ESTUDIO SISMICO ESPECIFICO DE SITIO: - SDS = 0.23G - CATEGORIAS DE DISENO SISMICO: B - PARAMETROS SISMICOS PARA OBTENCION DE FUERZAS EN EL SISTEMA: - "NO ESPECÍFICAMENTE DETALLADO DE RESISTENCIA SÍSMICA" (R=3, Ω=3, Cd=3) B. EL PROCEDIMIENTO DE ANALISIS EMPLEADO ES: FUERZAS EQUIVALENTES LATERALES EXCAVACIÓN DE LA CIMENTACIÓN Y RELLENO 1. LAS CIMENTACIÓNES FUERON DISENADAS DE ACUERDO CON EL REPORTE GEOTECNICO POR LAINCO LABORATORIOS CON FECHA REPORTE INVESTIGACION GEOTECNICA DE FECHA 15 OCTUBRE 2021. 2. EL REPRESENTANTE DE MECANICA DE SUELOS DEL DUEÑO DEBERÁ VERIFICAR LAS CARACTERISTICAS DEL SUELO PREVIO A LA COLOCACIÓN DEL CONCRETO. 3. LAS EXCAVACIONES DEBERÁN MANTENERSE LIBRES DE MATERIAL SUELTO Y AGUA ESTANCADA.. 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 11. SUMINISTRAR UNA GUIA EN LA PARTE SUPERIOR E INFERIOR DE LOS POSTES, EN LOS CABECEROS DE PUERTAS, VENTANAS Y HUECOS, EN LA PARTE INFERIOR DE LAS VENTANAS O HUECO. TODASL LAS GUIAS A INSTALAR SEGÚN SE REQUIERA DEBERAN DE SER DEL MISMO ESPESOR DE LOS POSTES. 12. LAS GUIAS QUE SE USEN EN LAS CHAMBRANAS, EN LA PARTE SUPERIOR DE HUECOS, PUERTAS, Y VENTANAS ASI COMO LAS NECESARIAS EN LA PARTE INFERIOR DE HUECOS Y/O VENTANAS DEBERAN SER CONTINUAS NO SE PERMITE LOS EMPALMES www.vestalcorporation.com TODAS LAS CONEXIONES ATRONILLADAS EN VIGAS O CONTRAVENTEOS DEBERAN DE CONTAR CON DOS TORNILLOS MINIMO O SU EQUIVALENTE EN SOLDADURA. TODO EL CONCRETO TENDRÁ UNA DENSIDAD MÍNIMA DE 2400 KG/M3 Y UNA RESISTENCIA MÍNIMA A LA COMPRESIÓN A LOS 28 DÍAS COMO SE INDICA A CONTINUACION: IK 1. PK APROBO: 9. CONCRETO DIBUJO: NO SE DEBERAN APRETAR LOS TORNILOS COMPLETAMENTE O REALIZAR LAS SOLDADURAS FINALES, HASTA QUE LA ESTRUCTURA HAYA SIDO COMPLETAMENTE ALINEADA. T: 314.439.9900 F: 314.439.9906 8. 21023-050000a-S003 NO DEBERAN REALIZARSE CAMBIOS EN TAMAÑO O POSICION DE LOS ELEMENTOS ESTRUCTURALES, ASI COMO TAMPOCO REALIZAR PERFORACIONES, RANURAS, CORTES, ETC., A LOS MISMOS. 1 : 10 7. TODO EL ACERO DE REFUERZO PRINCIPAL YA SEA VERTICAL Y HORIZONTAL CON EXCEPCIÓN DE AMARRES Y ESTRIBOS, DEBERAN ESTAR MECÁNICAMENTE EMPALMADOS O UNIDOS DE ACUERDO A LO ESPECIFICADO CONFORME AL PLANO DE DETALLES TIPICOS. ESCALA: 9. mm NO SE PERMITE EL EMPALME DE LOS ELEMENTOS DE ACERO, A MENOS QUE SE INDIQUE EN LOS PLANOS DIBUJO NO: 6. COTAS: LOS EMPALMES MECÁNICOS DEBEN ESTAR DE ACUERDO CON ACI 318 Y CAPACES DE DESARROLLAR POR LO MENOS EL 125 POR CIENTO DEL ESFUERZO DE FLUENCIA ESPECÍFICADO PARA LA BARRA. CORPORATION 8. THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 LAS CONEXIONES SOLDADAS DEBEN ESTAR DE ACUERDO CON AWS D1.1 "CÓDIGO DE SOLDADURA ESTRUCTURAL." ELECTRODOS DE SOLDADURA SERÁN E70XX. 7. GENERAL NOTES (NOTAS GENERALES) 5. EL RECUBRIMIENTO MÍNIMO DE CONCRETO SOBRE EL REFUERZO SERÁ DETALLADO EN LOS PLANOS. DONDE EL RECUBRIMIENTO NO ESTE DIMENSIONADO, UTILIZAR LAS DISPOSICIONES DE LA ACI 318. 26-JAN-2022 LA LONGITUD DE DESARROLLO DEL ACERO DE REFUERZO Y EL TRASLAPE DE LAS VARILLAS SE HARÁN DE ACUERDO CON ACI 318 TODOS LOS TRASLAPES SERÁN CLASE TIPO "B". EXCEPTO SE INDIQUE OTRA COSA. 6. 0 TODAS LAS CONEXIONES ATORNILLADAS DEBERAN UTILIZAR TORNILLOS A325N, A MENOS QUE SE INDIQUE LO CONTRARIO. AGUJEROS GRANDES Y AGUJEROS SOBREDIMENSIONADOS NO ESTÁN PERMITIDOS, A MENOS QUE SE INDIQUE EN LOS PLANOS. TODO EL ACERO DE REFUERZO DEBERÁ ESTAR APOYADO SOBRE SILLETAS Y ESPACIADO CON LOS ACCESORIOS NECESARIOS Y DEBERÁN ESTAR SÓLIDAMENTE AMARRADOS ENTRE SÍ, DE CONFORMIDAD CON ACI 318. IFC (REVIEW) SE DEBERA INFORMAR POR ESCRITO AL REPRESENTANTE DEL PROPIETARIO DE CUALQUIER DESVIACIÓN A LOS DOCUMENTOS DEL CONTRATO. CUALQUIER DESVIACION AL PROYECTO EN LOS PLANOS DE TALLER Y DIBUJOS DE CONSTRUCCION SERA RESPONSABILIDAD DEL CONTRATISTA, A MENOS DE QUE EXISTA DOCUMENTO ESCRITO DONDE EL REPRESENTANTE DEL PROPIETARIO APRUEBE Y HAYA DADO SU CONSENTIMIENTO PARA CUALQUIER DESVIACION ESPECIFICA O CAMBIO DE PROYECTO. 4. 5. 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE 8. PREVIO AL COLADO DEL CONCRETO SE DEBERA DE UBICAR Y DIMENSIONAR EL TAMAÑO DE LAS HUECOS, ELEMENTOS EMBEBIDOS NECESARIOS EN MUROS Y PISOS DE CADA UNA DE LAS DISCIPLINAS,Y QUE SE INDIQUEN EN LOS PLANOS: ARQUITECTÓNICOS, DE INSTALACIONES, MECANICOS Y ELECTRICOS, RESPETANDO DIMESIONES Y DETALLES. MOSTRADOS. A MENOS DE QUE SE ESPECIFIQUE OTRA COSA EN PLANOS, EL ESPESOR MINIMO DE LAS PLACAS DEBERA SER DE 10MM; EN ANCLAS EL DIAMETRO MINIMO SERA DE 19MM; EL TAMAÑO MÍNIMO DE SOLDADURA SERÁ DE 5MM. TODO REFUERZO SERA DETALLADO, FABRICADO Y COLOCADO, CONFORME AL ACI 315-99 " DETALLES TIPICOS Y HABILITADO DEL REFUERZO EN EL CONCRETO” Y CONFORME AL MANUAL DE PRACTICAS ESTANDARES DEL CRSI' DE 2008. FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: 7. LOS DETALLES MARCADOS COMO TIPICOS SE PODRAN USAR NO SOLO DONDE ESTA ESPECIFICADO O REFERENCIADO, SINO TAMBIEN EN DONDE SEAN SEMEJANTES LAS CONDICIONES DEL PROYECTO Y NO ESTEN MARCADOS COMO TAL. 3. 4. TITULO DEL PLANO: 6. LOS HUECOS PARA TUBERÍAS, BANCOS DE DUCTOS, ETC., QUE NO ESTEN INDICADOS EN LOS PLANOS ESTRUCTURALES DEBERÁN SER PRESENTADOS Y APROBADAS POR EL REPRESENTANTE DEL PROPIETARIO. PREVIO A LA INSTALACIÓN SE DEBERA DE INCLUIR LOS DETALLES DE REFUERZOS ESTRUCTURALES NECESARIOS, ASI COMO EL SELLADO EN PISO O MUROS. TODO EL ACERO ESTRUCTURAL DEBERA SER DETALLADO FABRICADO Y CONSTRUIDO SEGUN AISC “CÓDIGO DE PRÁCTICA ESTÁNDAR”. TODO EL ACERO DE REFUERZO, ANCLAS, PASADORES, INSERTOS, ETC. DEBERÁN ESTAR BIEN SUJETOS EN SU LUGAR Y REVISADOS POR EL REPRESENTANTE DEL PROPIETARIO ANTES DE VACIAR EL CONCRETO. FECHA / DATE 5. EL PROYECTO SE DEBERA DE COORDINAR CON TODAS LAS AREAS Y CUALQUIER CONFLICTO ENCONTRADO SE REPORTARA INMEDIATAMENTE AL REPRESENTANTE DEL PROPIETARIO. 2. 3. REVISIONES / REVISION 4. DETALLES ESPECIFICOS Y NOTAS, PREVALECERAN SOBRE LOS DETALLES TIPICOS, CUANDO EXISTAN DISCREPANCIA ENTRE LOS PLANOS, LAS ESPECIFICACIONES Y LAS NOTAS GENERALES DE LA ESTRUCTURA, LAS PREVISIONES MAS ESTRICTAS REGIRAN AL PROYECTO. TODO EL ACERO DE REFUERZO QUE VAYA A SER SOLDADO O EL QUE ESTÉ ESPECÍFICAMENTE INDICADO, DEBERÁ SER ACERO CORRUGADO ASTM A706 FASE DISEÑO / DESIGN PHASE 3. 2. DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 PREVIO AL INICIO LOS TRABAJOS SE DEBERAN DE VERIFICAR TODAS LAS DIMENSIONES Y CUALQUIER DISCREPANCIA ENCONTRADA SE DEBERA DE NOTIFICAR AL REPRESENTANTE DEL PROPIETARIO INMEDIATAMENTE. TODO EL ACERO ESTRUCTURAL SERA CONFORME A LOS SIGUIENTES GRADOS: A.PERFILES W Y WT SERAN A992 (Fy=3500 KG/CM2) B.ANGULOS, Y CANALES A36 (Fy=2500 KG/CM2) C.PLACAS BASE Y DE CONEXION A36 (Fy=2500 KG/CM2) D.TUBERIA ESTRUCTURAL A53 GRB (Fy=2450 KG/CM2) E.PERFILES HUECOS CUADRADOS O RECTANGULARES A500 GRB (Fy=3200 KG/CM2) F. PERFIL TUBULAR OC A500 Grado B (Fy = 2950 kg/cm2) EL ACERO DE REFUERZO DEBERA SERA MEDIANTE VARILLAS CORRUGADAS CONFORME A LA NORMA ASTM A-615, GR 60, A MENOS DE QUE SE INDIQUE OTRA COSA CLIENTE / CLIENT 2. ACERO ESTRUCTURAL 1. 1. FIRMA DE DISEÑO / DESIGN FIRM EL CRITERIO PARA LAS ESTRUCTURAS ESTA ESTABLECIDO EN LOS DIBUJOS Y EN LAS ESPECIFICACIONES, EN LOS CASOS QUE NO ESTE INDICADO EN LOS DOCUMENTOS ANTERIORES, ESTAS NOTAS SON LAS QUE REGIRAN AL PROYECTO. DIAGEO - EL CHARCON - ELEVATE II PROJECT 1. ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES ACERO DE REFUERZO NOTAS GENERALES W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO REVISIONES / REVISIONS NOTAS ESTRUCTURALES GENERALES . 3 .............................. 4 .............................. ABBREVIATION LEGEND (LEYENDA DE ABREVIACIONES): 5 .............................. Fxxx - CONCRETE FOOTING (ZAPATA DE CONCRETO) 6 .............................. 7 .............................. 8 .............................. 9 .............................. CCxxx - CONCRETE COLUMN (COLUMNA DE CONCRETO) 7072 500 SOGxxx - CONCRETE MAT SLAB (LOSA DE CIMENTACIÓN DE CONCRETO) 8 Px - CONCRETE PILASTER (DADO DE CONCRETO) S300 CWxx - CONCRETE WALL (MURO DE CONCRETO) 1200 5 S601 S601 OPP. 1 EQ MSxx- EQUIPMENT MAT SLAB (LOSA DE CIMENTACIÓN PARA EQUIPO) S601 U.N.O. - UNLESS NOTED OTHERWISE (A MENOS QUE SE INDIQUE LO CONTRARIO) MAT1000 TYP. - TYPICAL (TIPO) 4 S601 S601 M-5 P2-M F4.0 CW300 CF500 S200 4 S601 S601 PROCESS DRAIN. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION. 8870 M-2 S300 P2-M F4.0 OPP. 1 1 S601 S601 6 6 6 S601 S601 S601 S601 CF500 6 CW300 CF500 CW300 4 S501 CW300 P2-M F3.0 P2-M F3.0 CW300 CW300 P2-M F3.0 CW300 600 P2-M F3.0 CF500 N 2273653.911 E 753556.219 CF500 CF500 5 1 S601 S300 2 CF500 7072 7072 2 5 S300 S601 7072 6. FOR ANCHOR SCHEDULE AND DETAILS S601 7. REINFORCEMNT PLACEMENT AND CONSTRUCTION SEQUENCING MUST BE COORDINATED WITH THE AGAVE BUILDING FOUNDATIONS FOR ALL PILASTERS ALONG GRID M-7. 1. NIVEL DE PISO TERMINADO SOBRE EL NIVEL DEL MAR = 1599.600, TIPO (A MENOS QUE SE INDIQUE LO CONTRARIO). VER PLANO. 2. NIVEL TOPE DE PILASTRA DEL PERÍMETRO ES IGUAL AL NIVEL DE PISO TERMINADO 3. NIVEL TOPE DE ZAPATA SOBRE EL NIVEL DEL MAR (A MENOS QUE SE INDIQUE LO CONTRARIO) = VARIABLE - VER PLANO. 4. PARA NOTAS GENERALES - VER PLANO S003 5. PARA TABLAS - VER PLANO S600 6. PARA DETALLES Y TABLA DE ANCLAJES S601 7. LA COLOCACIÓN DEL REFUERZO Y LA SECUENCOA DE CONSTRUCCIÓN DEBEN COORDINARSE CON LAS CIMENTACIONES DEL EDIFICIO DE AGAVE PARA TODOS LOS DADOS A LO LARGO DEL EJE M-7. UTM COORDINATION VALUES (VALORES DE COORDINACIÓN UTM) P1-M F4.0 CF500 OPP. S200 500 FOR SCHEDULES SEE SHEET S600 . 795 1020 P2-M F4.0 S501 2600 7000 3380 P2-M F4.0 P1-M F4.0 CW300 5. 4 S501 4 FOR GENERAL NOTES SEE SHEET S002 . N xxxxxxx.xxx E xxxxxx.xxx 2 S300 4. 515 S300 TOP OF FOOTING ELEVATION ABOVE SEA LEVEL (U.N.O.) = VARIES - SEE PLAN. 400 1020 S300 SIM. CF500 1 1 CW300 P2-M F4.0 3 OPP. 4 CW600.B 3. 4270 S300 1 CF500 CF500 CW300 5 TOP OF PERIMETER PILASTER ELEVATION IS EQUAL TO FINISH FLOOR ELEVATION. P2-M F4.0 CF500 MAT1200 S300 M-3 LA CIMENTACIÓN Y LOSA DE PISO PARA EL EQUIPO DE MOLIENDA FORMAN PARTE DE UNA EMISIÓN DE DISEÑO SEPARADA Y NO SE MUESTRAN EN ESTE PAQUETE. CW300 3 2. NOTAS PLANO DE CIMIENTO: S300 P2-M F4.0 FINISH FLOOR ELEVATION ABOVE SEA LEVEL = 1599.600, TYP (U.N.O.). SEE PLAN. S601 6 7000 12230 1 3 2 T/WALL = 1596.200 7000 MILLS EQUIPMENT FOUNDATION AND SLAB-ONGRADE ARE PART OF A SEPARATE DESIGN RELEASE AND ARE NOT SHOWN IN THIS PACKAGE 1 S601 S300 S101 OPP. CW300 42000 CW600.A CW300 7000 S300 CF500 7 P2-M F4.0 1. FASE DISEÑO / DESIGN PHASE 4 FOUNDATION PLAN NOTES: CLIENTE / CLIENT S200 OPP. CF500 S200 P2-M F4.0 CW300 4 CF500 1 CW300 7000 P2-M F4.0 FIRMA DE DISEÑO / DESIGN FIRM M-6 PRINTED: 1/28/2022 14:04:29 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] SPxx - ANCHOR SETTING PATTERN (ARREGLO DE ANCLAJES) TYP UNO 7072 7072 500 35360 1 S100 FOUNDATION PLAN (PLANO DE CIMENTACION) 1 : 150 A M F KEY PLAN (PLANO CLAVE) TRUE NORTH 5 0 5 1:500 10 20 25m IK S601 E.W. - EACH WAY (AMBOS SENTIDOS) PK APROBO: S601 ELEVACION SUPERIOR CIMIENTO T/FTG= 1594.600 DIBUJO: 3 21023-050000a-S100 3 As indicated 3 ESCALA: 1 3 CF500 S601 OPP. S601 E.F. - EACH FACE (CADA CARA) mm S300 CF500 CW300 7000 4 BPxxx - BASE PLATE (PLACA BASE) P1-M NOTE 7 CORPORATION P2-M NOTE 7 REVISIONES / REVISION P2-M NOTE 7 DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 P2-M NOTE 7 REVISIONES / REVISIONS P2-M NOTE 7 CW300 P1-M S601 M-1 11 .............................. VBxx - VERTICAL BRACE (CONTRAVENTEO VERTICAL) 2 M-4 10 .............................. DIAGEO - EL CHARCON - ELEVATE II PROJECT O-8 M-7 GBxxx - GRADE BEAM (CONTRATRABE) PROCESS DRAIN. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION. DIBUJO NO: 7072 COTAS: 7072 FOUNDATION PLAN - MILLS (PLANO DE CIMENTACIÓN - MOLIENDA) 7072 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE 7072 FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: 500 www.vestalcorporation.com 17680 TITULO DEL PLANO: 17680 SEE OVENS FOUNDATION PACKAGE T: 314.439.9900 F: 314.439.9906 CFxx - CONTINUOUS FOOTING (ZAPATA CONTINUA) THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 35360 26-JAN-2022 .............................. 0 M-D 2 W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO FECHA / DATE M-C .............................. ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES M-B 1 IFC (REVIEW) KEYNOTE LEGEND 765 CW600.A 600 1 S101 2975 ° 30.00 2 R= 2975 ° 30.00 2375 MECHANICAL EQUIPMENT, TYP 7 S601 TANK 9 S601 0 .00 MAT1200 EMBED PLATE EM-1, TYP 12 PLACES EMBED PLATE EM-3, TYP 6 PLACES M-3 CW600.B 5895 8870 ANCHOR LAYOUT PLAN (PLANTA DE ARREGLO DE ANCLAJES) PROCESS DRAIN. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION. TANK www.vestalcorporation.com 5795 IK MAT1000 T: 314.439.9900 F: 314.439.9906 11 .............................. 26-JAN-2022 10 .............................. 0 3075 FECHA / DATE .............................. PK APROBO: TANK 9 DIBUJO: 5895 .............................. 21023-050000a-S101 S601 8 As indicated EMBED PLATE EM-2, TYP 18 PLACES .............................. ESCALA: 7 S601 7 mm 0 .05 .............................. DIBUJO NO: 9 6 COTAS: 0 .05 .............................. CORPORATION TANK 5 IFC (REVIEW) 5795 .............................. THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 ° 30.00 50 2.0 4 ANCHOR LAYOUT PLAN (PLANTA DE ARREGLO DE ANCLAJES) 2 R= PROCESS DRAIN. REFER TO PLUMBING DRAWINGS FOR EXACT LOCATION. .............................. REVISIONES / REVISION S601 3 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE 3075 9 .............................. FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: 3075 FASE DISEÑO / DESIGN PHASE 8 REVISIONES / REVISIONS CV03 T1830 TANK 3235 TANK 2 TITULO DEL PLANO: S601 2 R= CLIENTE / CLIENT 5105 3765 5795 .............................. ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES 8 R= FIRMA DE DISEÑO / DESIGN FIRM CV02 T1820 TANK 1340 M-7 1 DIAGEO - EL CHARCON - ELEVATE II PROJECT S601 60 .00 ° TY P(T IPO ) CV01 T1810 TANK 5095 5095 8 60 .00 ° TY P(T IPO ) 565 M-B KEYNOTE LEGEND DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 1 : 55 AJ01 T1310 TANK 7300 6735 S601 60 .00 ° TY P(T IPO ) 265 M-6 AJ02 T1320 TANK 5095 4830 M-4 600 3535 2170 M-5 1365 PRINTED: 1/28/2022 14:04:29 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] . W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO 0 .00 2 R= . 7000 M-4 7000 M-3 7000 7000 4 S300 3 CW600.A S300 T/WALL = 1596.200 CW600.A CJ CJ MAT1200 M-C 8750 M-C.1 8750 6 .............................. 7 .............................. 8 .............................. 9 .............................. FECHA / DATE M-C.2 M-D 8750 7072 .............................. 8750 7072 7072 7072 1000 (PISO TERMINADO) F. F. MILS 0.00 1595.600 CW300 CF500 P2-M CF500 F4.0 F4.0 P2-M CF500 P1-M CF500 F4.0 F4.0 7000 M-2 7000 M-1 7000 7000 3380 P2-M P2-M P2-M P2-M P2-M CW300 CF500 CF500 CF500 F4.0 F4.0 CF500 F4.0 CF500 F4.0 SEE OVENS FOUNDATION PACKAGE 4 S100 S200 WEST FOUNDATION ELEVATION (CIMENTACIONES - ALZADO OESTE) 1 : 150 2600 P1-M F. F. MILS 0.00 1595.600 300 P1-M 1020 CF500 F4.0 F4.0 As indicated 7000 M-3 FOUNDATION ELEVATIONS (ELEVACIONES DE CIMENTACIÓN) 7000 M-4 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE 1200 M-5 FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: M-6 TITULO DEL PLANO: O-8 M-7 1 : 150 DIAGEO - EL CHARCON - ELEVATE II PROJECT S100 S200 1000 3 ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES EAST FOUNDATION ELEVATION (CIMENTACIONES - ALZADO ESTE) DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 SEE OVENS FOUNDATION PACKAGE www.vestalcorporation.com CF500 F4.0 P2-M CW300 IK P2-M PB APROBO: 1200 DIBUJO: 7000 T: 314.439.9900 F: 314.439.9906 CF500 F4.0 7000 515 P2-M P1-M 7000 M-7 O-8 21023-050000a-S200 1020 7000 M-6 ESCALA: 7000 M-5 mm 300 F. F. MILS 0.00 1595.600 1000 PRINTED: 1/28/2022 14:04:33 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] (PISO TERMINADO) M-4 DIBUJO NO: M-3 7000 400 F4.0 CORPORATION M-2 4270 CF500 F3.0 1 : 150 S100 S200 795 CF500 F3.0 SOUTH FOUNDATION ELVATION (CIMENTACIONES - ALZADO SUR) 2 M-1 CF500 F3.0 CLIENTE / CLIENT CF500 F3.0 FIRMA DE DISEÑO / DESIGN FIRM CF500 F4.0 COTAS: 7072 5 FASE DISEÑO / DESIGN PHASE M-B.2 .............................. REVISIONES / REVISIONS CW600 1 : 150 S100 S200 4 11 .............................. WALL ELEVATION (CIMENTACIONES - ALZADO OESTE) 1 M-B M-B.1 12230 .............................. 800 CW600 17735 3 10 .............................. F. F. MILS 0.00 1595.600 1200 MAT1000 600 CJ CW600.B .............................. THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 T/WALL = 1599.600 2 26-JAN-2022 1200 M-5 W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO 0 M-6 .............................. REVISIONES / REVISION O-8 M-7 1 IFC (REVIEW) KEYNOTE LEGEND M-D SEE 1150 PLAN 600 500 CW600.A SEE PLAN & SCHEDULE SEE SCHEDULE SEE SCHEDULE BACKFILL WITH COMPACTED ENGINEERED FILL IN 200mm LIFTS CW300 SEE PLAN & SCHEDULE WATERPROOFING. SEE LEGEND CF500 SEE PLAN & SCHEDULE CLEAN OPEN GRADED CRUSHED STONE 1000 CONT. WALL REINFORCEMENT, SEE PLAN, SCHEDULE, AND DETAILS MAT1200 SEE PLAN & SCHEDULE WATERSTOP TYP. PILASTER REINFORCEMENT, SEE PLAN, SCHEDULE, AND DETAILS CONT. FOOTING REINFORCEMENT, SEE PLAN, SCHEDULE, AND DETAILS F. F. MILS 0.00 1595.600 WRAP WITH NON-WOVEN GEOTEXTILE FABRIC 100mm PERFORATED PIPE SEE SCHEDULE SEE SCHEDULE CW600 800 SEE GENERAL NOTES FOR SUBGRADE PREPARATION NOTE: DRAIN OCCURS ONLY ALONG GRID O-A BETWEEN GRIDS O-8 & O-13. FOOTING REINFORCEMENT, SEE PLAN, AND SCHEDULE SEE GENERAL NOTES FOR SUBGRADE PREPARATION 1 S100 S300 SECTION (SECCIÓN) 2 1 : 20 S100 S300 SEE SCHEDULE SEE GENERAL NOTES FOR SUBGRADE PREPARATION 600 4000 SECTION (SECCIÓN) SEE SCHEDULE SECTION (SECCIÓN) 3 1 : 20 CLIENTE / CLIENT 100mm PERFORATED PIPE FASE DISEÑO / DESIGN PHASE 1000 WRAP WITH NONWOVEN GEOTEXTILE FABRIC 1 : 25 S100 S300 26-JAN-2022 SOG NOT INCLUDED IN THIS PACKAGE CLEAN OPEN GRADED CRUSHED STONE 0 LENTON ANCHOR, TYP 10mm PRE-MOLDED JOINT FILLER AND SEALANT, TYP WALL BEYOND GRADE / PAVEMENT FOR REFERENCE ONLY, TYP ANCLAJES, TIPO, VER TABLA DE ANCLAJE IFC (REVIEW) F. F. MILS 0.00 1595.600 12 180 #5 @ 600mm ± o.c. PLACE FIRST DOWEL 100mm FROM CORNER OF THE WALLS TO RECEIVE CMU BLOCKS ADDITIONAL #4 STIRRUPS @ 75mm o.c. SOG NOT INCLUDED IN THIS PACKAGE LÍNEA DE CENTRO DE ARREGLO DE PERNOS LÍNEA DE CENTRO DE LA COLUMNA FECHA / DATE VERTICAL BARS, SEE SCHEDULE, PROVIDE STANDARD HOOK INTO FOUNDATION 11 850 CMU FOR REFERENCE ONLY. NOT INCLUDED IN THIS PACKAGE 10mm PRE-MOLDED JOINT FILLER AND SEALANT, TYP VARÍA W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO REVISIONES / REVISION CMU FOR REFERENCE ONLY. NOT INCLUDED IN THIS PACKAGE 4 650 300 #5 @ 600mm ± o.c. PLACE FIRST DOWEL 100mm FROM CORNER OF THE WALLS TO RECEIVE CMU BLOCKS IGUAL REVISIONES / REVISIONS 300 2 2000 MAX. 100 100 EVERY THIRD CELL 600 ± CW300 KEYNOTE LEGEND M-D M-C.2 M-B M-B.1 100mm PERFORATED PIPE 1 : 25 S100 S300 O-8 M-7 1200 M-6 7000 1 : 25 S100 S300 M-5 7000 SEE SCHEDULE 7 M-4 M-3 7000 7000 MAT1000 MAT1200 1200 1000 SEE GENERAL NOTES FOR SUBGRADE PREPARATION SEE SCHEDULE 1 : 25 600 SEE SCHEDULE F. F. MILS 0.00 1595.600 2000 12230 S100 S300 CW600.B SEE SCHEDULE 600 4 1365 8 S100 S300 SECTION (SECCIÓN) 1 : 75 1 : 25 www.vestalcorporation.com IK S100 S300 6 SECTION (SECCIÓN) PB APROBO: 5 SECTION (SECCIÓN) STYROFOAM FILLER (RELLENO DE POLIESTIREN AISLANTE) DIBUJO: SECTION (SECCIÓN) 10mm JOINT FILLER AND SEALANT. (RELLENO DE JUNTAS Y SELLADORE DE 10mm) 21023-050000a-S300 STYROFOAM FILLER (RELLENO DE POLIESTIREN AISLANTE) As indicated WRAP WITH NON-WOVEN GEOTEXTILE FABRIC NOTE: FOR BALANCE OF INFO SEE SECTION 2 / S300 NOTE: FOR BALANCE OF INFO SEE SECTION 1 / S300 ESCALA: MAT1000 SEE PLAN & SCHEDULE 10mm JOINT FILLER AND SEALANT. (RELLENO DE JUNTAS Y SELLADORE DE 10mm) mm TENSION LAP DIBUJO NO: 2000 STYROFOAM FILLER (RELLENO DE POLIESTIREN AISLANTE) F. F. MILS 0.00 1595.600 SECTION (SECCIÓN) F4.0 BEYOND COTAS: CF500 TENSION LAP NOTE: FOR BALANCE OF INFO SEE SECTION 1 / S300 SEE SCHEDULE CW600 P2-M F4.0 F4.0 SEE SCHEDULE 1000 1200 1200 4000 MAX. CLEAN OPEN GRADED CRUSHED STONE CW300 10mm JOINT FILLER AND SEALANT. (RELLENO DE JUNTAS Y SELLADORE DE 10mm) T: 314.439.9900 F: 314.439.9906 CW300 CW300 WATERSTOP TYP. SEE SCHEDULE F. F. MILS 0.00 1595.600 CORPORATION MAT1000 #5 @ 200 THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 CW600.A SEE PLAN & SCHEDULE #10 @ 300 FOUNDATION SECTIONS AND DETAILS (CIMENTACION SECCIONES Y DETALLES) MAT1200 F. F. MILS 0.00 1595.600 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE #5 @ 200 FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: #10 @ 300 TITULO DEL PLANO: MAT1200 F. F. MILS 0.00 1595.600 SOG NOT INCLUDED IN THIS PACKAGE ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES SEE SCHEDULE SOG NOT INCLUDED IN THIS PACKAGE (6) #10 @ 300 200 180 #5 @ 600mm ± o.c. PLACE FIRST DOWEL 100mm FROM CORNER OF THE WALLS TO RECEIVE CMU BLOCKS #5 @ 600mm ± o.c. PLACE FIRST DOWEL 100mm FROM CORNER OF THE WALLS TO RECEIVE CMU BLOCKS SOG NOT INCLUDED IN THIS PACKAGE (3) #10 @ 300 300 DIAGEO - EL CHARCON - ELEVATE II PROJECT SEE SCHEDULE 180 850 DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 300 200 180 650 FIRMA DE DISEÑO / DESIGN FIRM 500 #5 @ 600mm ± o.c. PLACE FIRST DOWEL 100mm FROM CORNER OF THE WALLS TO RECEIVE CMU BLOCKS 1000 PRINTED: 1/28/2022 14:04:37 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] 300 M-B M-B.1 1150 M-B M-B.1 TENSION LAP SPLICE "B" (EMPALME A TENSIÓN "B") BAR SIZE (TAMAÑO DE VARILLA) TOP BARS (VARILLAS SUPERIORES) OTHER BARS (OTRAS VARILLAS) #3 650mm 500mm COMPRESSION LAP SPLICE (EMPALME A COMPRESIÓN) BAR SIZE (TAMAÑO DE VARILLA) W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO TENSION LAP SPLICE "B" (EMPALME DE TENSIÓN "B") COMPRESSION LAP SPLICE TOP BARS OTHER BARS (EMPALME DE (VARILLAS (OTRAS COMPRESIÓN) SUPERIORES) VARILLAS) 950mm 600mm #6 1150mm 850mm 600mm #8 2050mm 1600mm 800mm #8 1850mm 1450mm 800mm #10 2600mm 2000mm 1000mm #10 2350mm 1800mm 1000mm #12 3050mm 2400mm 1150mm #12 2750mm 2150mm 1150mm d D 135 DEGREE (135 GRADOS) . IN M N. m I m M 75 mm R 5 O O7 6 D 6D ( d 2 S500 3 S500 1 : 20 135 DEGREE (135 GRADOS) BACK GOUGE (SANEADO DE RAÍZ) #4 SEISMIC STIRRUP/ TIES (ESTRIBOS SÍSMICOS/ AMARRES) BAR SIZE (VARILLA#) 135° A or G A or G H 40mm 100mm 100mm 65mm 50mm 115mm 115mm 75mm (LONGITUD DE TRASLAPE) (LONGITUD DE TRASLAPE) 135° D A or G H #3 40mm 115mm 75mm #4 50mm 115mm 75mm 3mm TYPICAL CONCRETE REINFORCING @ CORNER DETAIL (CONCRETO REFORZADO TIPICO EN DETALLE DE ESQUINA) 1 : 16 MECHANICAL COUPLER (COPLE MECANICO) MANUFACTURER (FABRICANTE) BACK GOUGE (SANEADO DE RAÍZ) INTERSECTIONS (INTERSECCIONES) ONE LAYER (UNA CAPA) REINFORCEMENT, SEE APPROPRIATE SECTIÓN FOR ADDITIONAL INFORMATION (REFUERZO, VER LA SECCION CORREPONDIENTE PARA INFORMACIÓN ADICIONAL) PRODUCT LINE (LINEA DEL PRODUCTO) DEXTRA BARTEC DAYTON TAPER LOCK DAYTON BAR-LOCK BARSPLICE BPI-GRIP XL 3 mm #3 90° LAP SPLICE MECHANICAL COUPLER PER SCHEDULE (EMPALME MECÁNICO VER TABLA) REINFORCING SPLICE SCHEDULE (TABLA DE EMPALME DE REFUERZO) 3 mm. D ALTERNATE HOOK (GANCHOS ALTERNADOS) LAP SPLICE TWO LAYERS (DOS CAPAS) 45° STIRRUP HOOKS (TIE BEND SIMILAR) (GANCHOS EN ESTRIBOS (AMARRE DOBLEZ SIMILAR) ONE LAYER (UNA CAPA) CORNERS (ESQUINAS) Tc = 350 KG/CM2 - NORMAL WEIGHT CONCRETE (Tc = 350 KG/CM2 - CONCRETO DE PESO NORMAL) 45° TO 60° BAR SIZE (VARILLA#) TWO LAYERS (DOS CAPAS) 3 mm 65mm 155mm 140mm 95mm #5 65mm 140mm 95mm #6 115mm 305mm 205mm 115mm #6 115mm 205mm 115mm #8 140mm 355mm 230mm 135mm #8 140mm 230mm 135mm #10 155mm 410mm 270mm 155mm #10 155mm 270mm 155mm SINGLE - BEVEL - GROOVE WELD (SOLDADURA DE PENETRACION SENCILLA) NOTES: 1. ASTM A706 REBAR ONLY SINGLE - V - GROOVE WELD (SOLDADURA DE PENETRACION EN V) (NOTAS: LENTON 1 S500 1:5 6 S500 LOCK 1. UNICAMENTE EN VARILLAS ASTMA706) DETAILS OF REINFORCEMENT (DETALLES DE REFUERZO) REINFORCEMENT BAR HOOK DIMENSIONS (DIMENSIONES DE BARRA DE GANCHO DE REFUERZO) POSITION TAPER THREADED GRIP TWIST (EMPALME VARILLA MACHO HEMBRA) BARSPLICE REINFORCING BAR FIELD WELDING (SOLDADURA EN CAMPO DE VARILLAS DE REFUERZO) NOTES NOTAS: 1. 1. ALL COUPLERS LISTED IN TABLE ARE PERMITTED TO BE USED UNLESS RESTRICTION PROVIDED IN SPECIFIC DETAIL. SUBSTITUTIONS ARE ALLOWED FOR EQUAL PRODUCTS NOT SHOWN IF PRODUCT IS SUBMITTED TO ENGINEER AND APPROVED AS EQUAL FOR USE. 1 : 16 TODOS LOS EMPALMES MOSTRADOS EN LA TABLA SE PODRAN USAR A MENOS QUE SE INDIQUE UNA RESTRICCIÓN EN ALGUN DETALLE ESPECÍFICO ESTAN PERMITIDAS LAS SUSTITUCIONES PARA PRODUCTOS IGUALES NO MOSTRADOS SI EL PRODUCTO SE SUBMITE A APROBACION POR EL INGENIERO PARA SU USO 1 : 16 SPLICE TOP OR BOTTOM BARS (PARTE SUP. O INF. DE VARILLAS) SPLICE LENGTH +300 mm (LONGITUD DE EMPALME +300mm) SPLICE (1500 mm MIN) STAGGER SPLICE OF TOP & BOTTOM REINF, NO TWO ADJACENT BARS ARE SPLICED AT THE SAME POINT (ESCALONAR EMPALME DE REFUERZO PARTE INFERIOR Y SUPERIOR, NO SE DEBERÁN COLOCAR LOS EMPALMES DE DOS VARILLAS ADYACENTES EN EL MISMO PUNTO) 5 S500 HORIZ BEAM BAR TYP (REFUERZO HORIZONTAL DE VIGAS) BARTEC LENTON FORM SAVER MECHANICAL END ANCHOR PER SCHEDULE (COPLE ANCLAJE MECÁNICO EN EL EXTREMO) REINFORCEMENT, SEE APPROPRIATE SECTION FOR ADDITIONAL INFORMATION (VER LA SECCIÓN CORRESPONDIENTE PARA INFORMACIÓN ADICIONAL) END ANCHOR (ANCLAJE EN EXTREMO) MANUFACTURER PRODUCT LINE (FABRICANTE) (LINEA DEL PRODUCTO) FOR SLAB, MAT FOUNDATION & CONTINUOUS FOOTINGS (PARA FIRME, LOSA DE CIMENTACIÓN Y ZAPATAS CORRIDAS) DEXTRA DEXTRA BARTEC LENTON TERMINATOR TYPICAL STAGGERED REBAR SPLICE DETAIL (DETALLE TÍPICO DE REFUERZO ESCALONADO) 1 : 16 7 S500 MODEL # PER REINFORCEMENT SIZE (MODELO CON BASE AL NUMERO DE VARILLA) 6 8 10 BEASC #6 BEASC #8 BEASC #10 12 REQUIREMENTS FOR END ANCHOR USE (REQUERIMIENTOS PARA USO DE COPLES DE ANCLAJE EN LOS EXTREMOS) N/A EL20D14 EL25D14 EL32D14 EL38D14 96mm 127mm 132mm 180mm 48mm 64mm 80mm 90mm MIN BAR SPACING OC (CLARO LIBRE MINIMO ENTRE VARILLAS) MIN CONCRETE COVER TO CENTER OF REINF BAR (RECUBRIMIENTO MÍNIMO DEL CONCRETO AL CENTRO VARILLA REFUERZO) REINFORCING MECHANICAL COUPLER SCHEDULE (TABLAS DE COPLES MECÁNICOS PARA EMPALME DE VARILLAS.) 1 : 16 As indicated S500 TYPICAL TYPE II MECHANICAL REBAR LAP SPLICE DETAIL (DETALLE TÍPICO DE EMPALME MECÁNICO DE REFUERZO ESCALONADO TIPO II) ESCALA: 4 MANUFACTURER PRODUCT LINE (FRABRICANTE) (LINEA DEL PRODUCTO) TYPICAL DETAILS (DETALLES TÍPICOS) HORIZ BEAM BAR TYP (REFUERZO HORIZONTAL DE VIGAS) FOR COLUMNS AND BEAMS (PARA COLUMNAS Y VIGAS) 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE FORM SAVER COUPLER (CIMBRA PARA COPLES DE ANCLAJE DE VARILLAS) FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: FORM SAVER ANCHOR PER SCHEDULE (CIMBRA CON COPLE PARA ANCLAJE DE VARILLAS VER TABLA) TITULO DEL PLANO: REINFORCEMENT, SEE APPROPRIATE SECTION FOR ADDITIONAL INFORMATION (ACERO DE REFUERZO, VER LA SECCIÓN CORRESPONDIENTE PARA INFORMACION ADICIONAL) ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES MECHANICAL REBAR SPLICE TYP (EMPALME MECÁNICO TIPO) 600 DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 CONC COLD JOINT (JUNTA FRÍA EN CONCRETO) DIAGEO - EL CHARCON - ELEVATE II PROJECT PRINTED: 1/28/2022 14:04:39 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] #5 www.vestalcorporation.com 1250mm IK #6 PK APROBO: 500mm DIBUJO: 750mm T: 314.439.9900 F: 314.439.9906 950mm 21023-050000a-S500 #5 mm 500mm FECHA / DATE 800mm CORNER BARS TO MATCH WALL REINFORCING (LAS VARILLAS DE LAS ESQUINAS DEBEN SER LAS MISMAS QUE LAS DEL ARMADO DE LOS MUROS) DIBUJO NO: D D 1050mm 3. OTHER MEMBERS: CONCRETE COVER LARGE AND EQUAL db AND C.C. BAR SPACING LARGE OR EQUAL 3db. WHERE THESE CONDITIONS ARE NOT MET TABULATED VALUES SHALL BE MULTIPLIED BY A FACTOR OF 1.5. (OTROS ELEMENTOS ESTRUCTURALES; RECUBRIMIENTO EN EL CONCRETO MAYOR O IGUAL QUE EL db Y EL ESPACIAMIENTO CENTRO A CENTRO DE VARILLAS MAYOR O IGUAL QUE 3db) (DONDE ESTAS CONDICIONES NO SE CUMPLAN LOS VALORES MOSTRADOS EN LA TABLA DEBERÁN SER MULTIPLICADOS POR UN VALOR DE 1.5) H H D (GANCHO A O G) HOOK A OR G (GANCHO A O G) HOOK A OR G D - BEND DIAMETER (D- DIAMETRO DE DOBLEZ) A OR G D #5 2. ALL TABULATED REBAR SHALL SATISFY THE FOLLOWING BEAMS AND COLUMNS: CONCRETE COVER LARGE OR EQUAL db AND C.C. BAR SPACING LARGE OR EQUAL 2 db AND STIRRUPS OR TIES THROUGHOUT DEVELOPMENT LENGTH (Ld) NOT LESS THAN THE CODE MINNIMUM. (TODOS LOS VALORES MOSTRADOS EN LA TABLA PARA LAS VARILLAS DE REFUERZO DEBERÁN CUMPLIR CON LO SIGUIENTE): (EN VIGAS Y COLUMNAS: RECUBRIMIENTO EN EL CONCRETO MAYOR O IGUAL QUE EL DIAMETRO DE LA VARILLA Y LA SEPARACION CENTRO A CENTRO ENTRE VARILLAS MAYOR O IGUAL QUE 2db Y EN ESTRIBOS EN TODA LA LONGITUD DE DESAROLLO (Ld) NO MENOR A LO QUE ESPECIFICA EN EL REGLAMENTO. 6D DIMENSION 400mm 1. THESE VALUES ARE BASED ON ACI/ 318-14 FOR GRADE 60 UNCOATED REINFORCING ALL LAPSPLICES SHALL BE TYPE "B" TENSION SPLICES U.N.O. (ESTOS VALORES ESTAN BASADOS EN AC/ 318-14 PARA ACERO GRADO 60 SIN RECUBRIMIENTO TODOS LOS EMPALMES DEBERÁN SER TIPO "B" A MENOS QUE SE INDIQUE OTRA COSA). D 90 DEGREE (90 GRADOS) 600mm NOTE (NOTA): STANDARD HOOK AT LONGITUDINAL BARS GANCHO ESTANDAR EN VARILLAS LONGITUDINALES) d 750mm Tc = 300 KG/CM2 - NORMAL WEIGHT CONCRETE (Tc = 300 KG/CM2 - CONCRETO DE PESO NORMAL) BEND AT STIRRUPS (DOBLEZ EN ESTRIBOS) FOR #3, #4, #5 - 6d FOR #6, #7, #8 -12d #4 COTAS: 8d 400mm CORPORATION #10 TO #11 (#32 AL #36) 650mm THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 6d HOOK TO 135°(DOBLEZ A HOOK TO 90° (DOBLEZ A 90°) BEND DIAMETER D (DIAMETRO DE DOBLEZ D) #3 TO #8 (#10 AL #25) 850mm 6d 4d BAR SIZE (VARILLA #) #4 0 d EXTENSION (LONGITUD DE TRASLAPE) IFC (REVIEW) D 12d d 180 DEGREE HOOK (DOBLEZ A 180 GRADOS) (LONGITUD DE TRASLAPE) CLIENTE / CLIENT d D N O 6d SI N TE EX 90 DEGREE HOOK (DOBLEZ A 90 GRADOS) LAP SPLICE FIRMA DE DISEÑO / DESIGN FIRM ALTERNATE BEAM REINFORCEMENT(REFUERZO (4d TYPICAL BEAM REINFORCEMENT(ARREGLO TIPO DE REFUERZO EN VIGAS) 4 D I d BE AM N ET D D RO IA S ME (4d 4d DE TE DI BE DO R AM N BL ET D D EZ RO IAM ) S D ET E D ER OB LE Z) Smin d Smin=25 ó d LAP SPLICE 300mm REVISIONES / REVISION 450mm FASE DISEÑO / DESIGN PHASE 600mm REVISIONES / REVISIONS #3 300mm 26-JAN-2022 d . SEAL AS REQ'D (SELLO COMO SE REQUIERA) 8 MANGA 9 TUBO O TUBERIA 10 CARA INFERIOR DE LA VIGA DE PISO 11 50mm LIBRE AL REFUERZO 12 LONGITUD DE TRASLAPE PARA TENSION 13 MANGA. MINIMO 14 ESPESOR DE LOSA 15 AJUSTAR EL REFUERZO DEL MURO PARA ABERTURAS LIBRES DONDE LAS BARRAS HORIZONTALES O VERTICALES SEAN CORTADAS PARA PROVEER LAS ABERTURAS, AGREGAR REFUERZOS HORIZONTALES Y VERTICALES A AMBOS LADOS DE LAS ABERTURAS (# DE BARRAS A CADA LADO DEBERAN SER 1/2 DE LAS BARRAS CORTADA PERO NO MENOS QUE UNA ) 16 ABERTURAS MULTIPLES - DETALLE "A" 17 CORTE DE BARRA VERTICAL EN ABERTURA 18 CORTE DE BARRA HORIZONTAL EN ABERTURA 19 DIAMETRO MAYOR A DOS MANGAS ADJACENTES (MINIMO) 20 LONGITUD EN EXCESO ACUMULADA MAXIMA DE LA ABERTURA EN EL MURO UNIDA POR DOS PILASTRAS O POR DOS ELEMENTOS COLINDANTES, NO DEBEN EXCEDER DEL 10% DE LA LONGITUD DEL MURO 21 2-#5X5'-0" (1500mm) BARRAS DIAGONALES SEE PLAN (VER PLANO) PIPE PENETRATION @ WALL (PENETRACIÓN DE TUBERÍA @ MURO) 1 : 10 22 23 VERT. BAR CUT AT OPENING 17 16 SINGLE OPENINGS - DETAIL "B" ADJUST WALL REINF. TO CLEAR OPENINGS WHERE VERT. OR HORIZ. BARS ARE CUT TO PROVIDE OPENINGS, ADD ADDITIONAL VERT. & HORIZ. REINF. ON BOTH SIDES OF OPENING (# OF BARS ON EACH SIDE TO BE 1/2 OF BARS THAT ARE CUT, BUT NOT LESS THAN ONE) (AJUSTAR EL REFUERSO DE LA PARED PARA LIBRAR LAS APERTURAS DONDE DONDE SE CORTAN ARMADURAS DE REFUERSO VERTICALES U HORIZONTALES EN AMBOS LADOS DE LA APERTURA (# DE BARRAS A CADA LADO SERA 1/2 DE LAS BARRAS QUE SE CORTAN PERO NO MENOS DE UNA)) 2-#5x5'-0"(1500mm) DIAGONAL BARS 22 27 29 TOPE DE TRABE DE CIMENTACION 30 0" ACEPTABLE 31 ABIERTO 32 MURO VER PLANO TOP OF GRADE BEAM (COTA SUPERIOR VIGA DE PISO) 33 CLAVIJAS DE TRABE DE CIMENTACION 34 NOTA: PARA INFORMACIÓN ADICIONAL VER DETALLE "A" Y DETALLE "B" GRADE BEAM SEE PLAN (VIGA EN PISO, VER PLANO) 35 TRASLAPE DE TENSIÓN (TIPO) 36 ABIERTO OPENING AT BOT OF WALL AT TOP OF GRADE BEAM CONDITION - DETAIL "C" 21 ABBREVIATION LEGEND (LEYENDA DE ABREVIACIONES): PD - PIPE DIAMETER (DIÁMETRO DE LA TUBO) SD - SLEEVE DIAMETER (DIÁMETRO DE LA MANGA) CL - CENTERLINE (LINEA CENTRAL) MAXIMUM CUMULATIVE OPENING LENGTH IN EXCESS OF THAT SHOWN IN A WALL BOUNDED BY TWO PILASTERS OR TWO BOUNDARY ELEMENTS SHALL NOT EXCEED 10% OF WALL LENGTH. (LA LONGITUD MAXIMA ACUMULADA DE LAS APERTURAS EXCEDIENDO LA CORRESPONDIENTE A LA DE UNA PARED CONFINADA ENTRE DOS PILASTRAS O DOS ELEMENTOS NO DEBERA EXCEDER EL 10% DE LA LONGITUD DE ESTA) TYPICAL OPENINGS IN CONCRETE WALL DETAIL (DETALLE TIPO DE ABERTURAS EN MURO DE CONCRETO) 3 t t/3 MAT REINF NOT SHOWN FOR CLARITY, SEE SECTIONS AND SCHEDULE (EL REFUERZO DE LA LOSA DE CIMENTACIÓN NO SE MUESTRA POR CLARIDAD, VER SECCIONES Y TABLA) NOTE: FOR BALANCE OF INFORMATIONS SEE SLAB ON GRADE PACKAGE. 4 S501 SEE PLAN & SCHEDULE FOR WALL INFO (VER PLANO/TABLA PARA INFORMACIÓN DEL MURO) TYPICAL SECTION AT DOOR (SECCIÓN TÍPICA EN LA PUERTA) 1 : 15 3/4" (19mm) SMOOTH DOWEL @ 450 OC (ANCLAJE LISO DE 3/4" (19mm) @ 450 A CENTRO) 5 S501 SYNKO-FLEX FR WATERSTOP OR APPROVED EQUAL (WATERSTOP SYNKO-FLEZ FR O IGUAL APROBADO) WALL CONSTRUCTION JOINT TYP (JUNTA DE CONSTRUCCIÓN DE MURO, TIPO) 1 : 10 3/4" (19mm) SMOOTH DOWEL @ 450 OC (ANCLAJE LISO DE 3/4" (19mm) @ 450 A CENTRO) 6 S501 WALL CONTROL JOINT, TYP (JUNTA DE CONTROL DE MURO, TIPO) 1 : 10 7 S501 TYPICAL WATERSTOP DETAIL (DETALLE TIPO DE WATERSTOP - BANDA IMPERMEABLE) 1 : 10 As indicated t/2 300 21 MAT FDN SEE PLAN AND SCHEDULE (LOSA DE CIMENTACIÓN - VER PLANTA Y TABLA) ESCALA: 9 SEE PLAN CONTAINMENT WALL / CURB, SEE PLAN AND SECTIONS (MURO DE CONTENCIÓN / BORDILLO, VER PLANTA Y SECCIONES) TYPICAL DETAILS (DETALLES TÍPICOS) SLAB ON GRADE 7 SEE S.O.G. PACKAGE FIN FLOOR LUBRICATE (LUBRICAR) 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE LUBRICATE (LUBRICAR) SYNKO-FLEX FR WATERSTOP OR APPROVED EQUAL (WATERSTOP SYNKO-FLEZ FR O IGUAL APROBADO) FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: #5 DOWEL @ 300 JOINT SEALANT TYP (SELLADOR DE JUNTA, TIPO) TITULO DEL PLANO: 6 3/4" (19mm) SMOOTH DOWEL @ 450 OC (ANCLAJE LISO DE 3/4" (19mm) @ 450 A CENTRO) ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES 600 JOINT SEALANT TYP (SELLADOR DE JUNTA, TIPO) DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 3/4" (19mm) SMOOTH DOWEL @ 450 OC (ANCLAJE LISO DE 3/4" (19mm) @ 450 A CENTRO) REINF SEE SECTIONS ON PLAN (REFUERZO - VER SECCIONES EN PLANO) 6mm MAX. 6mm MAX. t/6 TYP (TIPO) 4 t/2 1 t/6 TYP (TIPO) GRID DIAGEO - EL CHARCON - ELEVATE II PROJECT 1 : 15 S501 750 PRINTED: 1/28/2022 14:04:40 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] MULTIPLE OPENINGS - DETAIL "A" ADDITIONAL VERT. BARS ADDED EA. SIDE OF OPENING PER DETAIL "A" (REFUERZO VERTICAL ADICIONAL. ANADIDAS A CADA LADO DE LA APERTURA SEGUN DETALLE "A") 30 t 35 TENSION LAP (TYP.) 35 OPEN www.vestalcorporation.com OPEN TENSION LAP (TYP.) 31 IK 36 28 ABERTURA AL FONDO DEL MURO AL TOPE DE LA CONDICION DE LA TRABE DE CIMENTACION - DETALLE "C" TRABE DE CIMENTACION VER PLANO 27 PK APROBO: 35 26 FIRMA DE DISEÑO / DESIGN FIRM 18 25 VERT. BARS PER WALL SECTION (REFUEZO VERTICAL DE ACUERDO A LA SECCION DE LA PARED) WALL SEE PLAN ADDITIONAL HORIZ. BARS (VER PLANO DE PARED) ADDED EA. SIDE OF OPENING PER DETAIL "A" (REFUERZO VERTICAL NOTE: ADICIONAL. ANADIDAS A SEE DETAIL "A" AND DETAIL CADA LADO DE LA APERTURA "B" FOR ADDITIONAL SEGUN DETALLE "A") INFORMATION (NOTA: VERT. BARS CUT DUE TO VERS DETALLE "A" Y OPENING DETALLE "B" PARA (SIM. @ HORIZ. BARS) INFORMACION ADICIONAL) (REFUEZO VERTICAL CORTADO POR LA APERTURA (IGUAL PARA GRADE BEAM DWLS BARRAS HORIZONTALES) (DOVELAS DE VIGA EN PISO) 0" ACCEPTABLE TENSION LAP (TYP.) 24 HORIZ. BAR CUT AT OPENING (CORTE DE BARRA HORIZONTAL EN LA APERTURA) TENSION LAP (TYP.) 35 LARGER DIAMETER OF TWO ADJACENT SLEEVES (MINIMUM) (COMO MINIMO IGUAL AL MAYOR DE LOS DIAMETROS DE DOS CAMISAS CONTIGUAS) ABERTURAS SIMPLES - DETALLE "B" BARRA VERTICALES ADICIONALES A CADA LADO DE LA ABERTURA VER DETALLE "A" BARRA VERTICALES CORTADAS DEBIDO A ABERTURAS (SIM @BARRAS HORIZONTALES) BARRA HORIZONTALES ADICIONALES A CADA LADO DE LA ABERTURA CONFORME AL DETALLE "A" BARRA VERTICALES CONFORME A SECCION DEL MURO DIBUJO: S501 T: 314.439.9900 F: 314.439.9906 1 : 16 21023-050000a-S501 2 mm TYPICAL FOOTING CONSTRUCTION JOINT DETAIL (DETALLE TIPO DE CONSTRUCCIÓN DE JUNTA EN VIGA DE CIMENTACIÓN/ZAPATA) DIBUJO NO: JOINT LOCATION SHOULD BE PER APPROVED SHOP DRAWINGS. (LA UBICACION DE LA JUNTA DEBE SER SEGUN PLANOS DE OBRA APROBADOS) TOPE SUPERIOR DE LOSA DE LA VIGA DE CIMENTACIÓN COTAS: 2. 7 CORPORATION FOR FOOTING DEPTH OF 600mm. OR LESS PROVIDE A SINGLE SHEAR KEY CENTERED. (PARA CIMIENTOS DE 600MM DE PROFUNDIDAD O MENOR, UTILIZA UNA SOLA CLAVE A CORTANTE CENTRADA) ESTRIBOS DOBLES DE AMBOS LADOS @ 75mm A CENTRO THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 1. 6 26-JAN-2022 (PENDIENTE 1%) VER TABLA PARA EL DIAMETRO MAXIMO DEL AGUJERO 0 SLOPE 1% 5 IFC (REVIEW) (PENETRACIÓN EN MURO) WALL PENETRATION 115 150 115 (FIELD VERIFY LOCATION OF PIPE + REQUIRED DIM. FOR SEAL) (VERIFICAR EN CAMPO UBICACIÓN DE TUBO + DIAM. REQUERIDO PARA SELLO) FECHA / DATE PARA VIGAS DE PISO CON PERALTE DE 600mm O MENORES, PROPORCIONAR UNA JUNTA SIMPLE CON LLAVE DE CORTANTE CENTRADA AL PERALTE. LA UBICACION DE LA JUNTA DEBERA SER DE ACUERDO A LOS PLANOS DE TALLER APROBADOS REVISIONES / REVISION 3 4 BACKER ROD (VARILLA DE RESPALDO) NOTES (NOTAS): S501 PARA EL RUEFUERZO PARA LAS VIGAS DE PISO VER PLANO SONATUBE (SONOTUBO) FOR FOUNDATION SEE PLAN (PARA CIMIENTOS VER PLANO) 1 2 W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO FASE DISEÑO / DESIGN PHASE 40 TYP 40 EL REFUERZO SERA CORRIDO EN LAS JUNTAS DE CONSTRUCCION CLIENTE / CLIENT REINFORCEMENT TO BE CONTINUOUS AT CONSTRUCTION JOINT (EL REFUERZO DEBE SER CONTINUO EN LAS JUNTAS DE CONSTRUCCION) 1 REVISIONES / REVISIONS KEYNOTE LEGEND . 3000 4000 1000 1000 (11) #10 EA. WAY TOP & BOT. (14) #10 EA. WAY TOP & BOT. ..... ..... COMMENTS (OBSERVACIONES) ..... ..... WIDTH IN MM (ANCHO EN MM) THICKNESS IN MM (ESPESOR EN MM) CF500 1400 GRAN TOTAL (GRAND TOTAL): 3 500 (5) #5 CW300 CW600 CW600.A CW600.B GRAN TOTAL (GRAND TOTAL): 9 300 600 600 600 6 PARTE INFERIOR/TUERCA 7 NIVEL SUPERIOR DE CONCRETO 8 TUERCA 9 NO UTILIZADO 10 PUNTO DE SOLDADURA #5 @ 300mm (TOP & BOT.) REINFORCING (REFUERZO) WALL THICKNESS IN MM (ESPESOR DE MURO) PROYECCIÓN DE ROSACADO MÍNIMO 200mm REINFORCING (REFUERZO) LONG DIRECTION SHORT DIRECTION (DIRECCIÓN LARGA) (DIRECCIÓN CORTA) CONCRETE WALL REINFORCING SCHEDULE (TABLA DE REFUERZO DE MURO DE CONCRETO) MARK (MARCA) 5 HORIZONTAL EXTERIOR FACE INTERIOR FACE CENTER OF WALL ADDITIONAL TOP AND BOTTOM EXTERIOR FACE (CARA EXTERIOR) (CARA INTERIOR) (CENTRO DEL MURO) (ADICIONAL SUP. E INF.) (CARA EXTERIOR) #4 @ 300 OC #5 @ 150 OC #5 @ 150 OC #5 @ 300 OC #4 @ 300 OC #5 @ 150 OC #5 @ 150 OC #5 @ 300 OC VERTICAL INTERIOR FACE (CARA INTERIOR) #6 @ 300 OC #6 @ 150 OC #6 @ 300 OC #5 @ 300 OC #6 @ 300 OC #6 @ 150 OC #6 @ 300 OC #5 @ 300 OC CENTER OF WALL (CENTRO DEL MURO) COMMENTS (COMENTARIOS) SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS REVISIONES / REVISION MARK (MARCA) NO UTILIZADO FECHA / DATE CONCRETE CONTINUOUS FOOTING SCHEDULE (TABLA DE ZAPATA CONTINUA DE CONCRETO) 4 FASE DISEÑO / DESIGN PHASE F3.0 3000 F4.0 4000 GRAN TOTAL (GRAND TOTAL): 16 REINFORCING (REFUERZO) REINFORCING E.W. - U.N.O. (REFUERZO E.0. – A MENOS LONG DIRECTION SHORT DIRECTION QUE SE INDIQUE OTRO) (DIRECCCION LARGA) (DIRECCION CORTA) PLACA DE 13mm x 75mm x 75mm EN VARILLA DE ANCLAJE DE 32mm PLACA DE 10mm x 50mm x 50mm EN VARILLA DE ANCLAJE DE 19mm PLACA DE 13mm x 90mm x 90mm EN VARILLA DE ANCLAJE DE 38mm MARK (MARCA) PILASTER WIDTH IN MM (ANCHO DE DADO) P1-M P2-M GRAN TOTAL (GRAND TOTAL): 22 975 750 PILASTER LENGTH IN MM (LARGO DE DADO) PILASTER DIAMETER IN MM (DIÁMETRO DE DADO) VERTICAL BARS (VARILLAS VERTICALES) TIES REINF (ESTRIBOS DE REFUERZO) COMMENTS (COMENTARIOS) (16) #10 (12) # 10 #4 @ 200 mm OC #4 @ 200 mm OC SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS SEE DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS 1150 1150 CONCRETE MAT SCHEDULE (TABLA LOSA DE CONCRETO DE CIMENTACION) MARK (MARCA) REINF. E.W. - U.N.O. (REFUERZO E.W. - U.N.O.) MAT1000 MAT1200 GRAN TOTAL (GRAND TOTAL): 2 REINF. SHORT DIR. (REFUERZO DIRECCIÓN CORTA) REINF. LONG DIR. (REFUERZO DIRECCIÓN LARGA) REMARKS (OBSERVACIONES) #10 @ 300 E.W. T&B #10 @ 300 E.W. T&B #10 @ 300 E.W. T&B #10 @ 300 E.W. T&B ************************ ************************ CLIENTE / CLIENT CONCRETE PILASTER SCHEDULE (TABLA DE DADOS DE CONCRETO) 26-JAN-2022 THICKNESS IN MM (ESPESOR EN MM) NO UTILIZADO 0 WIDTH IN MM (ANCHO EN MM) 2 W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO REVISIONES / REVISIONS LENGTH IN MM (LONGITUD EN MM) REFERNCIA DE DADO/MURO O ARREGLO DE ANCLAJE 3 CONCRETE SPREAD FOOTING SCHEDULE (TABLA DE ZAPATA DE CIMENTACION DE CONCRETO) MARK (MARCA) 1 IFC (REVIEW) KEYNOTE LEGEND (LEYENDA DE NOTAS CLAVE) www.vestalcorporation.com T: 314.439.9900 F: 314.439.9906 CORPORATION 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE PK APROBO: DIBUJO: 21023-050000a-S600 DIBUJO NO: COTAS: SCHEDULES (TABLAS) mm ESCALA: 1 : 10 IK FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: TITULO DEL PLANO: ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 FIRMA DE DISEÑO / DESIGN FIRM DIAGEO - EL CHARCON - ELEVATE II PROJECT PRINTED: 1/28/2022 14:04:42 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] NOTE: * SEE SECTIONS FOR ADDITIONAL REQUIREMENTS. (VER SECCIONES PARA INFORMACION ADICIONAL) . KEYNOTE LEGEND 650 "P" PEMB BASE PLATE AR-1 1 3/8"Ø 12 3'-0" 55 6" PB-1 AR-2 1 1/8"Ø 12 3'-0" 55 6" PB-2 40 NUT & WASHER 47 AR-3 1"Ø 8 2'-2" 55 6" PB-3 AR-4 1 3/8"Ø 12 3'-0" 55 6" PB-4 AR-5 1 1/8"Ø 12 3'-0" 55 6" PB-2 M-7 750 CW300 (12) 1 3/8" Ø ANCHOR BOLTS 120 260 ANCHOR SETTING PATTERN CORRESPONDS WITH PRE-ENGINEERED METAL BUILDING (PEMB) BASE PLATES PB-1 975 .............................. 7 .............................. 8 .............................. 9 .............................. 10 .............................. 11 .............................. 51 NOTAS: 1. COORDINAR TODOS LOS TAMAÑOS, CANTIDADES Y UBICACIONES DE PERNOS DE ANCLAJE CON LOS PLANOS DE LA EDIFICACIÓN DE ACERO DE PRE-INGENIERÍA (PEMB). 2. CONSULTAR PLANO DE PEMB E-1101 REV_0 CON FECHA DEL 22 DE DICIEMBRE DEL 2021, PARA LA COORDINACIÓN CON LA TABLA DE PERNOS DE ANCLAJE Y DETALLES. ANCHOR SETTING PATTERN CORRESPONDS WITH PRE-ENGINEERED METAL BUILDING (PEMB) BASE PLATES PB-2 ANCHOR SETTING PATTERN AR-2 (ARREGLO DE ANCLAJES AR-2) 2 1 : 20 1 : 20 S100 S601 SEE OVENS FOUNDATION PACKAGE M-B FACE OF PEMB COLUMN FACE OF PEMB COLUMN 1150 650 500 650 125 260 125 TIES, SEE SCHEDULE (8) 1" Ø ANCHOR BOLTS P1-M 750 60 120 (12) 1 1/8" Ø ANCHOR BOLTS M-1 CW300 16 ANCHOR ROD WITH LEVELING NUT - SIZE PER TANK MANUFACTURER 16 ANCHOR ROD WITH LEVELING NUT - SIZE PER TANK MANUFACTURER 24 ANCHOR ROD WITH LEVELING NUT - SEE STEEL PACKAGE 17 40mm MIN. NON SHRINK GROUT UNDER BASE PLATE 17 40mm MIN. NON SHRINK GROUT UNDER BASE PLATE 18 25mm THK. EMBED PLATE A304 SS STAINLESS STEEL 225 19 19 SLOPE 17 40mm MIN. NON SHRINK GROUT UNDER BASE PLATE 25 51mm THK.A572 GRADE 50 EMBED PLATE 19 SLOPE 9 - #8 A706 REBAR 21 CW300 #4 TIES @ 75mm LOSA DE CIMENTACIÓN REFUERZO NO SE MUESTRA POR CLARIDAD 8 FOUNDATION MAT REINFORCEMENT NOT SHOWN FOR CLARITY (TYP) (TIPO) 8 600 325 (8) 1" Ø ANCHOR BOLTS (TYP) (TIPO) 850 N.T.S. FOUNDATION MAT REINFORCEMENT NOT SHOWN FOR CLARITY 125 175 CJP ROD TO EMBED PLATE, 20 TYP LOSA DE CIMENTACIÓN REFUERZO NO SE MUESTRA POR CLARIDAD 9 - #8 A706 REBAR 21 (TYP) (TIPO) 8 27 9 - #8 REBAR #4 TIES 28 29 LENTON ANCHOR 22 270 100 EM-1 EMBED PLATE DETAIL (DETALLE DE PLACA EMBEBIDA EM-1) 1 : 15 270 270 100 8 S101 S601 50 #4 TIES 100 200 200 29 100 600 740 TYPICAL AT TANK / EQUIPMENT SUPPORTS TÍPICO EN SOPORTES DE TANQUE / EQUIPO S101 S601 200 100 740 50mm ⌀ VENT HOLE 100 270 270 50 LOSA DE CIMENTACIÓN REFUERZO NO SE MUESTRA POR CLARIDAD 100 100 100 7 23 50 740 270 740 1 : 20 50mm ⌀ VENT HOLE 22 100 100 50 23 50 270 50mm ⌀ VENT HOLE 270 50 ANCHOR SETTING PATTERN AR-6 (ARREGLO DE ANCLAJES AR-6) LENTON ANCHOR 200 22 FOUNDATION MAT REINFORCEMENT NOT SHOWN FOR CLARITY 600 LENTON ANCHOR 100 850 S100 S601 25mm THK. EMBED PLATE A304 SS STAINLESS STEEL SLOPE CONT. WALL REINF. THRU PILASTER ANCHOR SETTING PATTERN CORRESPONDS WITH PRE-ENGINEERED METAL BUILDING (PEMB) BASE PLATES PB-3 6 18 CJP ROD TO EMBED PLATE, 20 TYP P2-M 550 600 M-1 CJP ROD TO EMBED PLATE, 20 TYP TYPICAL AT TANK / EQUIPMENT SUPPORTS TÍPICO EN SOPORTES DE TANQUE / EQUIPO TYPICAL AT COLUMNS TÍPICO EN COLUMNAS EM-2 EMBED PLATE DETAIL (DETALLE DE PLACA EMBEBIDA EM-2) EM-3 EMBED PLATE DETAIL (DETALLE DE PLACA EMBEBIDA EM-3) 1 : 15 9 S101 S601 1 : 15 23 www.vestalcorporation.com COLUMN, SEE STEEL PACKAGE IK 26 PK APROBO: TANK BASE PLATE SIZE PER TANK MANUFACTURER DIBUJO: 4 T: 314.439.9900 F: 314.439.9906 TANK BASE PLATE SIZE PER TANK MANUFACTURER 21023-050000a-S601 4 As indicated 50 100 1 : 20 ESCALA: 50 100 375 S100 S601 mm VERT. DOWELS, SEE SCHEDULE 1 : 20 S100 S601 375 5 DIBUJO NO: 1 : 20 750 TIES, SEE SCHEDULE 4 ANCHOR SETTING PATTERN AR-5 (ARREGLO DE ANCLAJES AR-5) 600 S100 S601 ANCHOR SETTING PATTERN AR-4 (ARREGLO DE ANCLAJES AR-4) 75 3 ANCHOR SETTING PATTERN AR-3 (ARREGLO DE ANCLAJES AR-3) COTAS: ANCHOR SETTING PATTERN CORRESPONDS WITH PRE-ENGINEERED METAL BUILDING (PEMB) BASE PLATES PB-3 CORPORATION CONT. WALL REINF. THRU PILASTER 05 - MILLS BUILDING 00 - GENERAL 00 - GENERAL 030000 CONCRETE ANCHOR SETTING PATTERN CORRESPONDS WITH PRE-ENGINEERED METAL BUILDING (PEMB) BASE PLATES PB-2 FUNCTIONAL AREA: SUB AREA GROUP: SUB AREA OR SYSTEM: CSI CODE: CSI DESCRIPTION: ANCHOR SETTING PATTERN CORRESPONDS WITH PRE-ENGINEERED METAL BUILDING (PEMB) BASE PLATES PB-4 750 ANCHOR SCHEDULE AND DETAILS (DETALLES Y TABLA DE ANCLAJES) CORNER REINF. PER TYPICAL DETAILS 375 TITULO DEL PLANO: (12) 1 3/8" Ø ANCHOR BOLTS DOMICILIO / ADDRESS: KM8 CARRETERA ATOTONILCO - GUADALAJARA ATOTONILCO EL ALTO, JALISCO, C.P. 47779 P2-M THE PINES OFFICE CENTER 1 THE PINES COURT, SUITE A CHESTERFIELD, MO 63141 CONT. WALL REINF. THRU PILASTER 50 100 375 CW300 FIRMA DE DISEÑO / DESIGN FIRM 50 100 120 DIAGEO - EL CHARCON - ELEVATE II PROJECT TIES, SEE SCHEDULE 260 50 130 60 120 550 M.3 M.5 225 VERT. DOWELS, SEE SCHEDULE TIES, SEE SCHEDULE 120 375 175 CW300 325 M-7 50 CONT. WALL REINF. THRU PILASTER VERT. DOWELS, SEE SCHEDULE 50 130 P2-M VERT. DOWELS, SEE SCHEDULE 375 600 55 CLIENTE / CLIENT 500 975 1200 1150 375 600 M-B 600 O-8 PRINTED: 1/28/2022 14:04:48 C:\Users\peterkornacki\Documents\Revit 2020 Local Files\SF20-Tequila Distillery [email protected] 6 NOTES: 1. COORDINATE ALL ANCHOR BOLT SIZE, QUANTITIES AND LOCATIONS WITH PRE-ENGINEERED METAL BUILDING (PEMB) DRAWINGS. 2. REFERENCE PEMB DRAWING E-1101 REV_0 DATED DEC.22, 2021 FOR COORDINATION WITH ANCHOR BOLT SCHEDULE AND DETAILS. 1150 ANCHOR SETTING PATTERN AR-1 (ARREGLO DE ANCLAJES AR-1) S100 S601 .............................. (12) 1 1/8" Ø ANCHOR BOLTS 120 850 1 5 REVISIONES / REVISION P2-M .............................. P1-M 50 CONT. WALL REINF. THRU PILASTER 4 FASE DISEÑO / DESIGN PHASE M.6 51 .............................. CONT. WALL REINF. THRU PILASTER 375 60 120 M.4 T/NUT 3 ST.05.00.00.a - EDIFICIO DE MOLINOS - CIMENTACIONES 60 120 M.2 NUT 50 TACK TIES, SEE SCHEDULE 50 130 CW300 VERT. DOWELS, SEE SCHEDULE CORNER REINF. PER TYPICAL DETAILS "L" VERT. DOWELS, SEE SCHEDULE TIES, SEE SCHEDULE .............................. 375 125 50 130 260 375 125 "P" 55 LEVELING NUT 48 T/CONC. 49 2 REVISIONES / REVISIONS 500 600 1150 "L" GRADE 39 26-JAN-2022 O-8 FACE OF PEMB COLUMN 35 SEE OVENS FOUNDATION PACKAGE 650 ANCHOR QUANTITY 38 W, R E I O EV T F R O , OR Y - N ION IÓN F S T UE INAR UC EVI ARA S R R IS LIM ST A O P - ) N AR N N E PR CO O P AR - CIÓ D ITI IMIN RUC M (E REL NST P CO FECHA / DATE 500 ANCHOR SIZE 37 ANCHOR MARK ANCHOR SCHEDULE - PEMB BUILDING COLUMNS 13 (MIN) M-B 1150 .............................. 0 36 FACE OF PEMB COLUMN 1 IFC (REVIEW) M-B