1 IRIS NV – Parameter Speed curve configuration : F00 ~ F05 F00 Adjust starting acceleration F01 Adjust braking deceleration F02 S Jerk T0(S curve jerk start at start T0) F03 S Jerk T1(S curve jerk at end of acceleration T1) F04 S Jerk T2(S curve jerk at start of deceleration T2) F05 S Jerk T3(S curve jerk at end of deceleration T3) Speed F03 F00 F04 F01 F05 F02 Time 2 IRIS NV – Parameter F06 ~ F08 F06 Rated speed Unit: mm/s F07 Rated speed of the elevator Unit: RPM on the data plate of the motor F08 Encoder Pulses 8192 (by using T010 PG card) Motor Type BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF Load(Kg) 630 630 630 800 800 800 1000 1000 1000 1150 1150 1150 1350 1350 1350 1650 1650 1650 Speed (m/min) 60 90 105 60 90 105 60 90 105 60 90 105 60 90 105 60 90 105 Speed (mm/s) 1000 1500 1750 1000 1500 1750 1000 1500 1750 1000 1500 1750 1000 1500 1750 1000 1500 1750 RPM 96 144 168 96 144 168 96 144 168 91 136.5 159.2 91 136.5 159.2 91 136.5 159.2 3 IRIS NV – Parameter F06 ~ F08 F09 Parking floor by parking switch F10 Floor offset F11 Total number of floor Example) Eg. If 3rd floor, set “3” as decimal Eg. If 25 floor, set “25” Lift A Lift B Lift C 9 9 9 8 8 8 7 7 7 6 6 6 5 5 5 4 4 4 3 3 3 2 2 2 1 1 1 -1 -1 -2 Lift A Lift B Lift C F10 2 1 0 F11 9 10 11 4 IRIS NV – Parameter F12 ~ F17 F12 Rescue speed & inspection speed Unit: mm/s Fixed value (0.250 – 15m/min) F13 Re-leveling speed Unit: mm/s Fixed value (0.020 – 1.2m/min) F14 F15 Door-closing delay for hall calls Door-closing delay for car calls Unit: 0.1 second Unit: 0.1 second Example) a p e) Time to set 3 seconds 5 seconds 15 seconds Data 3 5 15 F16 Brake delay Unit: 0.1 second F17 Operation removal delay Unit: 0.1 second Operation command F16 Brake contactor F17 5 IRIS NV – Parameter F18 ~ F24 F18 Fire homing floor F19 Second fire homing floor F20 Homing delay time If no any call, elevator return after setting time F21 Leveling switch delay Unit: mm (Fixed value F22 1st homing floor If no any call, elevator return to setting floor F23 Group mode setting Unit: 0.1 second F24 NA Example) Homing floor setting (F22) 1st homing floor F22 F196 2nd homing floor (In case of duplex system, F196 works as a dispersion floor) Group mode setting (F23) 2 3 Group control (more than 3 elevators) Duplex or simplex 6) 6 IRIS NV – Parameter F25 ~ F28 F25 Display Binary value F26 F25 Input Type 1(X0-X15 Input N/O,N/C setup) Standard 12531 F26 Input Type 2(X16-X31 Input N/O,N/C setup) Standard 13184 F27 Input type 3(N.O./ N.C. setting for GX0- GX15 input point) Standard 0 F28 Input type 4(N.O./ N.C. setting for HX0- HX15 input point) Standard 671 1 X0 2 X1 4 X2 8 X3 16 X4 32 X5 64 X6 128 X7 256 X8 512 X9 1024 X10 2048 X11 4096 X12 8192 X13 16384 X14 32768 X15 I Inspect1 t1 I Inspect2 t2 UP D Down Up Dec1 (2LS) Dn Dec1 (1LS) Up Dec2 (4LS) Dn Dec2 (3LS) Governor (GOV) k Rl kmz Rly Fi 2/FR Fire2/FR DZ Relay R l Up Lmt. (UL) Dn Lmt. (DL) Up Lvl. (2LV) Dn Lvl. (1LV) * 1 * 1 0 0 * 1 * 1 * 1 * 1 0 0 0 0 * 1 * 1 0 0 X16 X17 X18 X19 X20 X21 X22 X23 X24 X25 X26 X27 X28 X29 X30 X31 KMC Rly SW Rly Brake (BY) Brk SW L (BS1) Brk SW R (BS2) Overheat (THB) EthQuak ALP UCM Rly Dr Lock (KAD) Fire1Rly . DZ SW. Fire Pre.open Fireman (Door Zone) (Fire Return) 0 0 0 0 0 0 * 1 * 1 * 1 0 0 * 1 * 1 0 0 GX1 GX2 GX3 GX4 GX5 GX6 GX7 GX8 GX9 GX10 GX11 GX12 GX13 GX14 GX15 Chg Dir Att Svc VIP Bypass Fireman2 Holdbtn C-Callp 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HX0 HX1 HX2 HX3 HX4 HX5 HX6 HX7 HX8 HX9 HX10 HX11 HX12 HX13 HX14 HX15 F28 OpnLmtF (DOL) ClsLmtF (DCL) DrBlkF (DB) SafEgF (SGS/SES) LgtCurF (PSGS /PSES) ZeroLoad FullLoad OverLoad OpnLmtR ClsLmtR DrBlkR LgtCurR SafEgR Display * 1 * 1 * 1 * 1 * 1 0 0 * 1 0 * 1 0 0 0 0 0 0 Display Binary value F27 Display Binary value Binary value 0 AntiCrm 7 IRIS NV – Parameter F29 ~ F31, F190 F29 F30 F31 F190 F29 Service floor setting 1(whether stop on floor 1-16) Standard 65535 F30 Service floor setting 2(whether stop on floor 17-32) Standard 65535 F31 Service floor setting 3(whether stop on floor 33-48) Standard 65535 F190 Service floor setting 4(whether stop on floor 49-64) Standard 65535 1 2 4 8 16 32 64 128 256 512 1024 2048 4096 8192 16384 32768 Floor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Display * * * * * * * * * * * * * * * * Binary 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Floor 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Display * * * * * * * * * * * * * * * * Binary 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Floor 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Display * * * * * * * * * * * * * * * * Binary 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Floor 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Display * * * * * * * * * * * * * * * * Binary 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8 IRIS NV – Parameter F32 ~ F35 F32 Specification of elevator integrated drive controller F33 Interval between trips in automatic running test Unit: Second F34 Number of trips in automatic running test # of automatic running F35 Special firefighter mode Standard Motor Type BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO BOMCO YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF YTW2-260GF Load(Kg) 630 630 630 800 800 800 1000 1000 1000 1150 1150 1150 1350 1350 1350 1650 1650 1650 Speed(m/min) 60 90 105 60 90 105 60 90 105 60 90 105 60 90 105 60 90 105 F32 0 2 2 1 2 2 1 3 3 2 3 3 2 3 4 2 4 5 Example) 0 F33 5 F34 100 • An elevator will run 100 times with 5 seconds interval between door opening timing & closing timing 9 IRIS NV – Parameter F36, F41, F43, F44, F48, F49 F36 Brake switch detection mode 1: Brake switch exists, 2: For Hong Kong code F41 Load Device Learn function 1: 0% load setting, 2: 100% load setting F43 Bit function parameter F44 Monitor Address Car ID for Step EMS F48 Zero Load Value Around 150~200 F49 Full Load Value Around 300~400 Bit setting (F43) Bit15 Standby KK Bit6 0: Without car call priority KK 1: With car call priority Bit5 Bit4 Bit3 Bit2 Bit1 0: Waiting with 0: No button 0: No hall IND display 0: No car call 0: No anti-crime door open in flash in in case of any fault function button buzzing attendant mode attendant 1: Hall IND flash is 1: Anti-crime 1: Car call 1: Waiting with 1: Button available in case of function button buzzing door close in flash in any fault attendant mode attendant Load Device Learn (F41, 48, 49) • Set “1” at F41 with 0% load in a car and set “2” with 100% load in a car. • If Learn is successfully made: The data (“1” or “2”) at F41 will be changed to “0” again once setting “1” or “2”. Data at F48 will be automatically changed to 50 ~ 150 for 0% load setting. Data at F49 will be automatically changed to 200 ~ 350 for 100% load setting Bit0 0: No button buzzing in attendant 1: Button buzzing in attendant 10 IRIS NV – Parameter F50 ~ F55, F191, F192 Front Rear F50 Front door-opening allowed 1 for floor 1-16 F51 Front door-opening allowed 2 for floor 17-32 F52 Front door-opening allowed 3 for floor 33-48 F191 Front door-opening allowed 4 for floor 49-64 F53 Rear door-opening allowed 1 for floor 1-16 0 F54 Rear door-opening allowed 2 for floor 17-32 0 F55 Rear door-opening allowed 3 for floor 33-48 0 F192 Rear door-opening allowed 4 for floor 49-64 0 1 2 4 8 16 32 64 128 256 512 1024 2048 4096 8192 16384 32768 F50 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 F51 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 F52 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 F191 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Display * * * * * * * * * * * * * * * * Binary 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 F53 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 F54 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 F55 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 F192 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Display - - - - - - - - - - - - - - - - Binary 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 IRIS NV – Parameter F56 ~ F62 F56 Leveling adjustment up 50 for baseline (Within 15mm) F57 Leveling adjustment down 50 for baseline (Within 15 mm) F58 Speed curve delay at start (Default) F59 Zero-speed band brake delay (Default) F61 Distance for triggering arrival gong/chime Chime interval fixed as 1200 F62 Time limit for anti-slippage operation For Chinese code (Max. 45 sec) Interval for F58, F59 KMB KMZ KMY DIR ENC RUN F58 SPEED F59 12 IRIS NV – Parameter F56 ~ F62 (Continuous) Setting for F56, F57 Elevator direction Elevator direction Car level ‘A’ Car level ‘A’ Landing sill level Landing sill level Car level ‘B’ Car level ‘B’ F56 Up direction F57 Down direction Car level ‘A’ Decrease the value Car level ‘A’ Increase the value Car level ‘B’ Increase the value Car level ‘B’ Decrease the value IRIS NV – Parameter F65 ~ F112 F65 1st floor name display F66 2nd floor name display F67 3rd floor name display ~ F111 47th floor name F112 48th floor name Example) F65 B2 F66 -2 F67 G F68 M F69 1 F70 2 1. 2. 3. 4. Go to F65 (or respective floor) by Para Setup. The default floor name will be displayed. Press ENTER on SVC tool. Cursor will be displayed for changing. 5. Press ▲ or ▼ to see available character. 6. Press ► or ◄ to move the curser to another digit. 7. Repeat step #5 and press ENTER to close. 13 IRIS NV – Parameter F115 ~ F121 F115 Open door overtime Open lock timer (Max. 30S) F116 Close door overtime Close lock timer (Max. 30S) F117 Holding time before forced door closing Button jam & keep pressing button F118 Holding time for the handicapped Open time for handicapped call F120 Number of registrations for anti-nuisance If 3, from 4th call will be cancelled F121 Forced door-closing enable For nudging operation: 1 Example) Overtime (F115, F116) If door is not closed (or opened) within setting value, close (or open) lock error is arisen. Holding time (F118) Door will be closed in setting value after fully opening in case of handicapped call. Anti-nuisance function (F120) 1. If setting value is 3, car calls will be cancelled from the 4th call. 2. Load detection shall be less than 20%. 14 15 IRIS NV – Parameter F123 ~ F130 F123 Landing call classification F124 Failure time of light curtain Photo disable time (Unit: Second) F125 Rear door light curtain disable time Photo disable time (Unit: Second) F127 Force stop floor setting F128 Separate door control for through type entrance F129 Micro leveling and/or running open function (Default : 0) F130 Holding door-opening/closing torque 0 4 Example) F123 0 1 F127 0 1 5 F128 0 1 Meaning Only front entrance Front & rear Meaning Not functioned Force stopped at 1st floor Force stopped at 5th floor Meaning Open separately (Front & rear) Open together F129 1 2 3 F130 0 1 2 3 4 Meaning Running open Micro leveling Both function Meaning No holding torque Holding open Holding close Both Holding in lift running IRIS NV – Parameter F131 ~ F133, F161 F132 1~64: Floor setting 65: Arrival chime cancel (Y) 66: 2nd homing floor time (Y) Start time 0~2359 F133 End time 0~2359 F161 To use for above function 0: Not use, 1: use F131 Example) F131 1. 1 ~ 64 Non-stop floor in setting time (F132, F133) 2. 65 Chime cancel in setting time (F132, F133) 3. 66 2nd homing floor in setting time (F132, F133) F132 & F133 1230 means 12H30M 2359 means 23H59M 16 17 IRIS NV – Parameter F137 ~ F139, 199 F137 F138 F139 F199 Service floor by NS-SW Service floor by NS-SW Service floor by NS-SW Service floor by NS-SW setting 1 (whether stop on Fl. 1-16) setting 2 (whether stop on Fl. 17-32) setting 3 (whether stop on Fl. 33-48) This floor can be selected by non stop switch at COP setting 4 (whether stop on Fl. 49-64) Example) 1 2 4 8 16 32 64 128 256 512 1024 2048 4096 8192 16384 32768 F137 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 F138 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 F139 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 F199 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Display * * * * * * * * * * * * * * * * Binary 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 IRIS NV – Parameter F140 ~ F147 F140 Weighing value of full load Set ‘80’ then hall call by-passed from 80% load F141 KMY release delay Refer to graph F142 Anti-crime floor Goes to this floor in case of no calling from outside F145 Bus voltage gain Fixed valve: 100 Allowed gap between actually position and learned position Selection of the protection method for contactor fault Real detecting floor & system stored floor is diffe rent, lift goes to terminal floor 0: Contactor cannot run with contactor error 1: Car can run even detection of contactor error F146 F147 18 19 IRIS NV – Parameter F148 ~ F155 F148 Door open time of the base floor Unit: 0.1S (30 means 3 seconds) F150 Indicator message selection (SM.0412/A, VS/T) F151 Indicator message selection (SM (SM.0412/B) 0412/B) SM.04 12/A SM.04 12/B 0 Upper Full, Lower Out of SVC 0 Left Full, Right Out of SVC 1 Upper Fire, Lower Out of SVC 1 Left Fire, Right Out of SVC 2 Upper Full, Lower Fire 2 Left Full, Right Fire 3 Upper Full, Left VIP, Right Out of SVC 3 Left(U) Out of SVC, Left(D) Full, Right VIP 4 Upper Fire, Left VIP, Right Out of SVC 4 Left(U) Out of SVC, Left(D) Fire, Right VIP IRIS NV – Parameter F148 ~ F155 F152 Delay for car-lighting before automatically switching off car-lighting and fan Units: 1 minute F153 Hall door lock check enable 0: No checking, 1: Checking F154 Voice announcement setting 0 ~ 65535 F155 Voice announcement setting 0 ~ 65535 20 21 IRIS NV – Parameter F160 ~ F172 F160 Cancelling car call Bit 0: Double click car call, Bit 1: Double for hall call, 2: Single click for car call, 3: Single for hall call F163 Lift running by generator power 0 Load type setting 7: JP9.2 (Signal received) 8: JP9.3 (Signal received) 9: Both (Signal received) F164 Return, 1 Continue F165 Door open mode 0: Door open in inspection 1: Door close in inspection F168 Elevator numbering for IC card service IC Card Key 0 F169 Setting landings for up/down calls by IC card 0: Up call, 1: Down call F170 F171 F172 With IC control in car, 1-16 Fl. for selection of identification by IC card With IC control in car, 17-32 Fl. for selection of identification by IC card With IC control in car, 33-48 Fl. for selection of identification by IC card Unused, 1 PTM1 EA PTM 2 EA Use IRIS NV – Parameter F175 ~ F186 F175 Creeping speed at start Don’t change F180 Velocity increment Default : 100 F181 Elevator numbering in duplex control 0: Main elevator, elevator 1: Sub elevator F182 Steps of speed reduction switches No. of slow down switch (Default : 1) F183 Speed for shaft teach mode Default : 0.8 (45 m/min) F186 Creeping time at start Don’t change 22 IRIS NV – Parameter F187 F187 SVC Tool display function 0: Running times 1: Eevaluation of encoder interference 2: Evaluation of CAN1 interference 3: Evaluation of CAN2 interference 4: Speed of motor 5: Voltage of DC bus 6: Output current (A) 7: Output torque 8: Position of pole 9: Encoder position 1 10: Encoder position 2 11: Pre-torque 12: Radiator temperature 1 13: Radiator temperature 2 14: Load-weight value 15: Weighing value JP9.2 of SM.02/I 16: Weighing value JP9.3 of SM.02/I 23 24 IRIS NV – Parameter F196 ~ F203 F196 2nd homing or dispersion floor in Duplex F200 DSP software revision number Don’t change F202 Auto turn for SINCOS Encoder Don’t change F203 No-load current, for the asynchronous motor Don’t change Example) F196 (Dispersion floor) Dispersion floor Homing floor IRIS NV – Parameter F204 ~ F215 F204 Zero speed proportion ASR P0 F210 Medium speed proportion ASR P3 F205 Zero speed integral ASR I0 F211 Medium speed Integral ASR I3 F206 Low speed proportion ASR P1 F212 High speed proportion ASR P4 F207 Lower speed integral ASR I1 F213 High speed Integral ASR I4 F208 Low speed proportion ASR P2 F214 Low speed switchover frequency 1 F209 Low speed Integral ASR I2 F215 High speed switchover frequency 2 25 26 IRIS NV – Parameter F218 ~ F222 F218 Motor Type Motor Type Load(Kg) Speed(m/min) F219 F221 F222 BOMCO 630 60 20 96 10.4 BOMCO 630 90 20 144 17.8 BOMCO 630 105 20 168 17.8 F219 Motor Poles F220 Rated motor voltage BOMCO 800 60 20 96 12.7 F221 Rated motor rotate speed BOMCO 800 90 20 144 21.7 F222 Rated motor current BOMCO 800 105 20 168 21.7 BOMCO 1000 60 20 96 14 9 14.9 BOMCO 1000 90 20 144 26 BOMCO 1000 105 20 168 26 YTW2-260GF 1150 60 16 91 17.9 YTW2-260GF 1150 90 16 136.5 26.9 YTW2-260GF 1150 105 16 159.2 31.4 YTW2-260GF 1350 60 16 91 21.1 YTW2-260GF 1350 90 16 136.5 31.6 YTW2-260GF 1350 105 16 159.2 36.8 YTW2-260GF 1650 60 16 91 25 YTW2-260GF 1650 90 16 136.5 37.4 YTW2-260GF 1650 105 16 159.2 43.7 IRIS NV – Parameter F223 ~ F231 F223 Max. output torque It should be more than 200 unless vibration F224 Motor slip frequency Default: 1.4 F225 Carrier frequency Default: 8 F226 Encoder type Default: 4 F227 Encoder pulses Default: 8192 F228 Magnetic pole phase Not used F229 Regulator mode Default: 1, Speed 2m/s & above: 0 F230 Pre-load type 0: No PTM 2: PTM use F231 Max. elevator speed Automatic record 27 IRIS NV – Parameter F231 ~ F249 F232 Motor reverse 0 or 1(Rotary Encoder ¢A, ¢B) F233 Encoder mode Defualt: 3100 F241 Weighing mode, overload up gain Full load UP (50) F242 Weighing mode, mode overload down gain Full load DOWN (50) F245 Weighing mode, light load up gain Empty load UP (80) F246 Current gain 2 EMpty load DOWN ( ~ 5.5kw : 250 ~ 300 7.5 ~ 15kw : 150 ~ 160 18.5kw : 100 Increase data by 5) F247 Balance value Half load data (512) F248 load analogue gain Default: 80, Adjsutable for motor vibration F249 Power code Same as F32 28 29 IRISSM.04V12/A NV – Parameter A A B 1,A: Full/Fire B: Out of Service 2,A:Full B:Fire B A: Full/Fire B: Inuse C C: Out of Service 30 IRISSM.04H12/B NV – Parameter A B 1,A:Fire/Full B:Out of Service 2,A:Full B:Fire C A A:Fire/Full B:Inuse C:Out of Service B 31 IRIS SM.04VS/T NV – Parameter A A B C B 1,A: Full/Fire B: Out of Service 2,A:Full B:Fire A: Full/Fire B: Inuse C: Out of Service 32 IRIS NV SM.04H12/B – Parameter A B 1,A:Fire/Full B:Out of Service 2,A:Full B:Fire A B C A:Fire/Full B:Inuse C:Out of Service
0
Puede agregar este documento a su colección de estudio (s)
Iniciar sesión Disponible sólo para usuarios autorizadosPuede agregar este documento a su lista guardada
Iniciar sesión Disponible sólo para usuarios autorizados(Para quejas, use otra forma )