Teaching Specification Cable type DM-18T (N,P) Photoelectric Sensor Type D SERIES Scanning range Supply voltage Current consumption Response time Timer ・DM-18T□□ INSTRUCTION MANUAL Light source Indicator Digital indicator Control output Operation mode Teaching Bank ● Confirm if the item meets your needs. ● Before the use, you should first thoroughly read this manual and operate correctly as mentioned. ● You should keep this manual at hand for proper use. Protection category/ material M8 Connector type DM-18TC (N,P) Select 'Bank' 18mm ± 2mm Select mode (Color or Mark) DC10 〜 30V including 10% ripple (P-P) 40mA max. Mark mode: 0.25/0.5/1.2ms selectable Display start blinking Color mode Mark mode R (634nm) / G (517nm) / B (469nm) Mark mode:1 color (selected by teaching) Color mode:RGB automatic selection 2 point teaching Auto teaching Adjust thresh lebel by Up or Down button Set the first object (color) Keep pushing teaching button Press teach button, then back to RUN status Output indicator(Orange LED) , Stable indicator (Green LED) 7 segment, 3 digits LED Green:Bank No. Red:Function, Status NPN/PNP Open collector 100mA max./ DC30V Set the object (color) Light ON / Dark ON selectable Mark mode:2 point teach/Auto teach Color mode:1point teach Push teaching button 8bank cable type: about 75g IfIf without without pressing teach Teach button button, it goes back to RUN to automatically 10 sec. after 10 s. buck RUN statusafter automatically Push teaching button IEC IP67 / Housing : heat-resistant ABS(antibacterial)Front cover : PMMA Button : TEEE / connector type: about 20g Through the object once Functions T NPN Release teaching button Press teach button or Reset (rS) T Press + button Press + button during more than 2 s. Press - button Press - button during more than 2 s. Remote Bank Selection Set the second object(color) RUN mode PNP Press Up or Down button Refer to 「FUNCTION」 Color mode: 0.8/1.6/4ms selectable Off delay / On delay / One shot delay (10msec increment :0-1,000msec, 1sec increment for 1-10sec) Weight Iuput/Output Circuit Design Manual adjustment of Threshold Cable type Push teaching button Bank No. 0 1 2 3 4 5 6 7 Yes T No OK Display ON/OFF (dP) NG T Display OFF Pin configuration ③ 0V Response time (rP) T Low (Resolution : High) Parts Name T Middle (Resolution : Middle) laser emitter indication Timer (dY) T One shot * For connector type only backside Turn the connector as Black Arrow indicates, otherwise you will damage the connector. The damage will be unrepairable. T RUN mode Thresh level adjust mode Function select mode Output is active for high reflection Output is active for low reflection ON delay 10ms OFF delay 990ms Without timer 1s Every 10 ms Every 1s Mark mode indicates amount Indicate remission of incoming light. Indicate thresh level. After teaching, thresh lebel is 50. L.ON/D.ON (Ld) 0 1 Dimensions T T No. 2 pin 0 1 Connector type can select only 1 and 2 by remoto selection. (Function select by button is 8 banks.) Key lock 0 Status Indicator Color mode Indicate matching level compare to teaching color. Indicate thresh lebel. After teaching, thresh lebel is 80. Mark mode L.ON D.ON Press both Up and Down button simultaneously for more than 2 sec. ( Same procedure for unlock.) foreside Teach / Enter Output is active when matched Output is active when un-matched Bank No. 0 1 When 2 point teach, the 1st selected color will be ON. Up button Down button Color mode L.ON D.ON High (Resolution : Low) output indicator digital display panel Yellow 0 1 0 1 0 1 0 1 Connector type L.ON/D.ON Display ON ② Bank ④ Control output Pink Rose 0 0 1 1 0 0 1 1 RUN mode T ① 10〜30V DC Green 0 0 0 0 1 1 1 1 NPN PNP NPN PNP Open or connect to +V Open or connect to 0V Connect to 0V Connect to +V Unit: mm ● 10 s Specifications and equipment are subject to change without any obligations on the part of manufacture. D.ON ● L.ON T For more information, questions and comments regarding products, please contact us below. Indicate selectable function. Warnings Color/Mark (CI) T Mark mode T For safety use Manufactured and sold by : Color mode ○ Warm-up period (approx. 100 msec) must be secured. ○ Should avoid to use sensor outside or at the place where receiver is influenced by environmental illuminance directly. ○ Gaps in indicated values and detection features are possible due to dispersion. T Bank (ch) Bank '0' 607-8085 Kyoto, Yamashina,Takehanadonomaecho 46-1, JAPAN Tel : +81-(0)75-594-8123 T ○ Use of controls or adjustments or performance of procedures other than the specified herein may result in hazardous radiation exposure. !Must not use this item as safety equipment for the purpose of human body protection. Fax : +81-(0)75-594-8124 Bank '7' RUN mode Response time, L.ON/D.ON, Color/Mark mode can be set for each Bank. Website : http//www.optex-fa.com 0535402 www.AlltronicsPeru.com