Subido por yovi_24_05

PLANO TERCER NIVEL - DESAGUE Y DRENAJE - REPLANTEO EN CAMPO

Anuncio
A
C.S.+7.60
.S.+7.55
C.I.+7.54
=0.01m)
1
B
D
E
C.S.+7.55
C.I.+7.54
(h=0. 01m)
Techo E1
Area:148.20m2
F
C.S.+7.55
C.I.+7.50
(h=0. 05m)
S=1.00%
G
C.S.+7.55
C.I.+7.54
(h=0. 01m)
Techo B1
Area:110.30m2
AZOTEA
H
S=0.63%
CNLT B1-Nº02
L=6.40m -A=0.15m
S=0.60%
S=0.63%
41
C.S.+7.55
C.I.+7.54
(h=0. 01m)
C.S.+7.55
C.I.+7.54
(h=0. 01m)
J
C.S.+7.55
C.I.+7.50
(h=0. 05m) 43
C AJA DE
REBOSE
0.30x0. 20m
S=0.60%
39
27
39
36
35
31
34
33
EXTRAC. AIRE
36
35
34
M
M
1
2
3
4
Cobertura para tanque
GLP
P:9%
DUCTO ELECTRICO
DRENAJE DE TECHO
MEDIA CAÑA
SUMIDERO
P:9%
COBERTURA TR3
O SIMILAR
CNLT B1-Nº02
L=6.66m -A=0.15m
EXTRAC. AIRE
FIRMA:
ENTIDAD:
B.D. Ø4"
S.V. Ø4"
S=0.60%
C.S.+7.55
C.I.+7.50
(h=0.05m)
S=0.60%
APOYO DE CONCRETO
C.S.+7.55
PARA TANQUE GLP
C.I.+7.54
ver det. lam. IMG-05
(h=0.01m)
PLANO DE DESAGUE Y DRENAJE TERCER NIVEL
PLANO:
"REHABILITACIÓN DE AMBIENTE PARA COMEDOR EN LA
SEDE INSTITUCIONAL DE ADUANAS DE CHUCUITO,
DISTRITO DEL CALLAO,PROVINCIA CONSTITUCIONAL DEL
CALLAO, DEPARTAMENTO CALLAO"
PROYECTO:
C.S.+7.55
C.I.+7.50
(h=0.05m)
TANQUE GLP
CNLT B1-Nº02
L=7.00m -A=0.15m
S=0.63%
Drenaje de techo Media caña
Cemento pulido
Cobertura para ducto
de TR3 o similar
Ver Det. en lam. D22
S=0.60%
COBERTURA TR3
O SIMILAR
Techo C1
Area:91.30m2
AZOTEA
N.T.T. + 7.55
Techo C2
Area:37.20m2
S=0.63%
C.S.+7.60
PISO CEMENTO SEMIPULDIO
CON IMPERMEABILIZANTE
Escalera de gato 2
Ver detalle en lam. D-10
S=0.60%
DE VE NTILACIÓN
LL.V. Ø4"
TERMI NA E N SOMBRERO
37
M .V. N°03
S .V. Ø4"
M .D. N° 05
B.D. Ø4"
S .V. Ø4"
C.S.+7.55
C.I.+7.54
(h=0. 01m)
PLANTA TERCER NIVEL
S=0.63%
L
P :9%
COBERTURA TR3
O SIMILAR
CNLT B1-Nº02
L=6.66m -A=0.15m
EXTRAC. AIRE
S=0.60%
C.S.+7.55
C.I.+7.50
(h=0. 05m)
APOYO DE CONCRETO
C.S.+7.55
PARA TANQUE GLP
C.I.+7.54
ver det.(h=0.
lam.01m)
IMG-05
CNLT B1-Nº02
L=7.00m -A=0.15m
S=0.63%
Dre naje de te cho Media caña
Cemento pulido
L
C.S.+7.55
C.I.+7.50
(h=0. 05m)
TANQUE GLP
C.S.+7.60
M uro Diviso rio
Drywall
S=0.63%
Cobertura para ducto
de TR3 o s imilar
Ver Det. en lam. D22
S=0.60%
DUCTO
M .D. N° 04
S .V. Ø4"
38
EXTRAC.
P :9%
COBERTURA TR3
O SIMILAR
C.S.+7.60
AZOTEA
N.T.T. + 7.55
Techo C2
Area:37.20m2
N.P.T. + 5.78
C.S.+7.60
PISO CEMENTO SEMIPULDIO
CON IMPERMEABILIZANTE
Techo C1
Area:91.30m2
C.S.+7.55
C.I.+7.50
(h=0. 05m)
PRECIPITADOR
LL.V. Ø75
DE GRASAS
C AJA DE
REBOSE
0.30x0. 20m
EXTRAC. AIRE
37
30
M .D. N° 03
S .V. Ø3"
CEMENTO SEMIPULIDO
Escalera de gato 2
Ver detalle e n lam. D-10
29
S=0.63%
38
28
32
DUCTO DE INSTALACIONES
ELECTRICAS
40
26
PARAPETO H= 0.90 cm
41
25
S=1.00%
42
CNLT B1-Nº02
L=6.36m -A=0.15m
24
K
S=1.00%
302
N.P.T. + 7.55
K
DUCTO DE INSTALACIONES
ELECTRICAS
40
S=0.63%
SARDINEL h=0.10m
CNLT B1-Nº02
L=6.66m -A=0.15m
PRECIPITADOR
DE GRASAS
COBERTURA TR3
O SIMILAR
P :9%
Cobertura para ducto
de TR3 o s imilar
Ver Det. en lam. D22
C.S.+7.55
COBERTURA
TR3
C.I.+7.54
O (h=0.
SIMILAR
01m)
C.S.+7.55
C.I.+7.54
(h=0. 01m)
ESCALERA DE
EVACUACION
CEMENTO SEMIPULIDO
S=1.00%
S=0.71%
CNLT B2-Nº02
L=5.60m -A=0.15m
J
C.S.+7.55
C.I.+7.50
(h=0.05m)
CREADO CON UNA VERSIÓN PARA ESTUDIANTES DE AUTODESK
CNLT B1-Nº02
L=6.66m -A=0.15m
I
42
B .D R.P.-Ø 3"
SUM.-Ø3"
I
CNLT B1-Nº02
L=6.40m -A=0.15m
CNLT B1-Nº02
L=6.36m -A=0.15m
Cobertura Sol y sombra
Ver det. en lamina D22
C.S.+7.55
C.I.+7.50
(h=0. 05m)
C.S.+7.60
C.S.+7.55
C.I.+7.50
(h=0. 05m)
S=1.00%
S=0.56%
CNLT B2-Nº02
L=7.20m -A=0.15m
H
S=1.00%
301
N.T.T. + 7.55
PISO CERAMICO 62.2 x 62.2
TIPO PIEDRA
Techo B2
Area:110.30m2
C.S.+7.55
C.I.+7.54
(h=0. 01m)
G
S=1.00%
S=0.63%
CNLT B2-Nº01
L=6.40m -A=0.15m
S=0.63%
CNLT B1-Nº01
L=6.40m -A=0.15m
C.S.+7.55
C.I.+7.50
(h=0.05m) 43
SARDINEL h=0.10m
B .D R.P.-Ø 3"
SUM.-Ø3"
B .D R.P.-Ø 3"
SUM.-Ø3"
S=0.63%
CNLT B1-Nº01
L=6.15m -A=0.15m
S=0.65%
Dre naje de te cho Media caña
Cemento pulido
C.S.+7.60
C.S.+7.55
C.I.+7.50
(h=0. 05m)
F
CREADO CON UNA VERSIÓN PARA ESTUDIANTES DE AUTODESK
C.S.+7.54
C.I.+7.53
(h=0. 01m)
S=0.65%
CNLT B2-Nº01
L=6.15m -A=0.15m
SUM.-Ø3"
P :9%
S=1.00%
S=1.00%
S=0.81%
CNLT B1-Nº01
L=3.72m -A=0.15m
B .D R.AA .-Ø2"
SUM.-Ø2"
Cobertura Sol y sombra
Ver det. en lamina D22
Estructura de aluminio
C.S.+7.60
tubo re ctangular 101. 6x38.1x2.34mm
Techo A1
Area:129.05m2
B .D R.P.-Ø 3"
SUM.-Ø3"
Tabique de Drywall
Junta de dilatación
C.S.+7.55
C.I.+7.54
(h=0.01m)
C
M .D. N° 02
LL.V. Ø4"
S=0.81%
C.S.+7.54
Dre naje de te cho Media caña
C.I.+7.50
CNLT B1-Nº01
Cemento
pulido
(h=0. 04m)
L=3.72m -A=0.15m
DUCTO
CNLT F1-Nº01
L=1.90m -A=0.15m
Sardine l S=1.05%
H= 0.10 cm
C.S.+11.25
C.I.+11.24
(h=0. 01m)
C.S.+11.28
S=1.00%
COBERTURA TR3
TECHO
O SIMILAR
ASCENSOR
Techo F1
CEMENTO SEMIPULIDO
Area:6. 75m2
N.T.T. + 11.25
LEYENDA
S=1.00%
P :9%
ASCENSOR
C.S.+7.55
C.I.+7.54
(h=0. 01m)
E
C.S.+11.25
C.I.+11.22
(h=0. 03m)
S=1.00%
C.S.+7.54
C.I.+7.53
(h=0. 01m)
C.S.+7.60
Escalera de gato 1
M .V. N° 02
Ver detalle e n lam. D-10
LL.V. Ø3"
D
S=1.00%
N.T.T. + 8.75
CNLT B1-Nº01
L=3.72m -A=0.15m
Cobertura Polic arbonato liso
Ver det. en lamina D22
C.S.+7.55
COBERTURA
TR3
C.I.+7.54
O SIMILAR
(h=0.01m)
PARAPETO h=1.20m
B .D R.P.-Ø 3"
SUM.-Ø3"
POLICARBONATO LISO
TECHO
Estructura de aluminio
tubo re ctangular 101. 6x38.1x2.34mm
C.S.+7.54
C.I.+7.50
(h=0. 04m)
Estructura de aluminio
tubo re ctangular 101. 6x38.1x2.34mm
S=0.81%
S=0.81%
AZOTEA
PISO CEMENTO SEMIPULDIO
M .D. N° 01
CON IMPERMEABILIZANTE
LL.V. Ø4"
N.T.T. + 7.55
Pede stal de c onc reto
acabado ce mento pulido
para equipo h=0.10m
M .V. N° 01
LL.V. Ø3"
Cobertura para ducto
de TR3 o s imilar
Ver Det. en lam. D22
C
S=1.00%
S=1.00%
C.S.+7.54
C.I.+7.53
PARAPETO h=1.80m
CNLT B1-Nº01
(h=0.Enc
01m)
hape eL=3.72m
n cara s -A=0.15m
uperior de
ladrillo pastelero
C.S.+7.60
B
S=1.00%
2
3
4
A
P :7%
UBICACION
PARAPETO H= 1.20 cm
S=1.00%
S=1.00%
CREADO CON UNA VERSIÓN PARA ESTUDIANTES DE AUTODESK
CREADO CON UNA VERSIÓN PARA ESTUDIANTES DE AUTODESK
Descargar