HOJA DE REVISION PROJECT NAME: 3059 - NHA6 PROJECT NUMBER: 2012-3059 UNIT TAG: SEE CHART ELEC. REV DATE POR: 1 2 3 4 5 6 12/30/2021 01/10/2021 01/19/2021 02/07/2021 03/02/2021 04/26/2022 C.M. C.M. C.M. C.M. C.M. E.R. 7 05/16/2022 E.R. DESCRIPCION: REQUERIDO: PAG. 5 Y PAG. 18 AGREGADOS, NUEVOS DETALLES DE SUJECION DE TUBERIA ELECTRICA E. RUIZ DETALLE DE QUICK CONNECTORS ACTUALIZADOS, LAMPARAS AGREGADAS Y SUBIDAS 10 E. RUIZ E. RUIZ E. RUIZ DETALLE DE CONEXION DE MODBUS EN MOTORES DE ABANICOS TABLA DE PARAMETROS DE VFD ELIMINADA. TRABALA DE SKUS Y NUEVOS TAGS CON SKU AGREGADOS RUTA DE CONDUITS DE LIGHTING Y J-BOXES MOVIDAS EN AREA DE SUPPLY AIR. SKU MODIFICADOS PARA INSTALACION DE CADDY CLAMP. TABLA DE TORQUES ACTUALIZADOS SE ACTUALIZO UBICACION DE CAJAS ""AS BUILT"", SE ACTUALIZO LISTA DE ETIQUETAS, SE ACTUALIZARON DETALLES DE CONEXION DE ACTUADORES SE CAMBIARON J-BOX DE 8X8X4 A 8X8X6, SE ACTUALIZO UBICACION DE LAMPARAS EN EL VESTIBULO DE CONTROLES Y VFD'S E. RUIZ Y PRODUCCION E. RUIZ Y PRODUCCION E. RUIZ NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SHEET INDEX PAGE 1 OF 47 CL-3059-LH-BD-MP-1 SHEET INDEX PAGE OVERALL 1 2 3 4 5 6 7 8 9 10 11 SHEET ID CL-3059-LH-BD-MP-1 CL-3059-LH-BD-MP-2 CL-3059-LH-BD-MP-3 CL-3059-LH-BD-MP-4 CL-3059-LH-BD-MP-5 CL-3059-LH-BD-MP-6 CL-3059-LH-BD-MP-7 CL-3059-LH-BD-MP-8 CL-3059-LH-BD-MP-9 CL-3059-LH-BD-MP-10 CL-3059-LH-BD-MP-11 12 13 14 15 16 17 18 19 20 21 CL-3059-LH-BD-MP-12 CL-3059-LH-BD-MP-13 CL-3059-LH-BD-MP-14 CL-3059-LH-BD-MP-15 CL-3059-LH-BD-MP-16 CL-3059-LH-BD-MP-17 CL-3059-LH-BD-MP-18 CL-3059-LH-BD-MP-19 CL-3059-LH-BD-MP-20 CL-3059-LH-BD-MP-21 22 23 24 25 26 27 28 29 CL-3059-LH-BD-MP-22 CL-3059-LH-BD-MP-23 CL-3059-LH-BD-MP-24 CL-3059-LH-BD-MP-25 CL-3059-LH-BD-MP-26 CL-3059-LH-BD-MP-27 CL-3059-LH-BD-MP-28 CL-3059-LH-BD-MP-29 30 31 32 CL-3059-LH-BD-MP-30 CL-3059-LH-BD-MP-31 CL-3059-LH-BD-MP-32 33 34 CL-3059-LH-BD-MP-33 CL-3059-LH-BD-MP-34 SHEET INDEX SHEET NAME SHEET INDEX TABLA DE TORQUE DE COMPONENTES ELECTRICOS TABLA DE TORQUE DE COMPONENTES ELECTRICOS DETALLE DE SUJECION DE CONDUITS SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES SPLIT 2 OVERHEAD CONDUIT LAYOUT PLAN VIEW SPLIT 2 PARED NORTE CONDUIT LAYOUT SPLIT 2 PARED ESTE Y PARTE ALTA DE VESTIBULOS PLAN VIEW SPLIT 2 DETALLE DE VENTILACION Y CONDUITS VACIOS SPLIT 2 PARED DE PRESION CONDUIT LAYOUT DETALLE DE CONEXION DE MODBUS EN SUPPY FANS DETALLE DE CONEXION DE SEÑALES EN SUPPLY FANS SPLIT 2 PARED SUR CONDUIT LAYOUT SPLIT 2 PARTE TRASERA DE DX COIL CONDUIT LAYOUT SPLIT 2 DETALLE DE LUCES PILOTO Y CONEXIONES DEL COIL SPLIT 2 DETALLES DE INSTALACION DE CONDUITS EN TECHO SPLIT 2 DETALLES DE INSTALACION DE CONDUITS EN TECHO DIAGRAMA DE CONEXION DE QUICK CONNECTOR EN MAQUINA SPLIT 1 CONDUIT LAYOUT PLAN VIEW DETALLE DE SUJECION DE CADDY CAMPS SPLIT 1 PARED NORTE CONDUIT LAYOUT SPLIT 1 PARED SUR CONDUIT LAYOUT SPLIT 1 AREA DE TRANSMITTER CONDUIT LAYOUT SPLIT 1 PARED ENTRADA DE EXHAUST FAN CONDUIT LAYOUT SPLIT 1 PARED OESTE CONDUIT LAYOUT SPLIT 1 PARED PARED DE DAMPERS EXHAUST AIR CONDUIT LAYOUT DETALLE DE FILTER GAUGE DETALLE DE INSTALACION DE VAISALA SENSOR DETALLE SENSOR DE TEMPERATURA DE DX COIL Y TRANSMITTER DETALLE DE INSTALACION DE LEAK DETECTOR DETALLES DE POSICION DE ACTUADORES PAGE 35 36 37 38 39 40 41 42 43 44 45 46 47 SHEET ID CL-3059-LH-BD-MP-35 CL-3059-LH-BD-MP-36 CL-3059-LH-BD-MP-37 CL-3059-LH-BD-MP-38 CL-3059-LH-BD-MP-39 CL-3059-LH-BD-MP-40 CL-3059-LH-BD-MP-41 CL-3059-LH-BD-MP-42 CL-3059-LH-BD-MP-43 CL-3059-LH-BD-MP-44 CL-3059-LH-BD-MP-45 CL-3059-LH-BD-MP-46 CL-3059-LH-BD-MP-47 SHEET NAME DETALLES DE POSICION DE ACTUADORES PRESSURE TIPS UBICACIONES DETALLE DE SSPP Y CONTROL PANEL TABLA DE ETIQUETAS DE CIRCUITOS 1 TABLA DE ETIQUETAS DE CIRCUITOS 2 TABLA DE ETIQUETAS DE CIRCUITOS 3 TABLA DE ETIQUETAS DE CIRCUITOS 4 TABLA DE ETIQUETAS DE CIRCUITOS 5 DIAGRAMA DE CONEXION DE ACTUADORES SUPPLY AIR DIAGRAMA DE CONEXION ACTUADORES DE DX 1 & 2 DIAGRAMA DE CONEXION ACTUADORES OA DMPR 2 DIAGRAMA DE CONEXION ACTUADORES OA DMPR 1 DIAGRAMA DE CONEXION ACTUADORES RA DMPR 47 LEFT HAND ITEMS UNIT TAG 1 6AHU-MP11 2 6AHU-MP21 3 4 6AHU-BD12 6AHU-BD21 5 6AHU-BD23 SHEET NOTES KEY PLAN NORTH 1 2 3/2/2022 2:32:30 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 1/2" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. TABLA DE TORQUE DE COMPONENTES ELECTRICOS CL-3059-LH-BD-MP-2 PAGE 2 OF 47 Job name: NCG5 Job number: 2007‐029 Unit Tag: AHU‐MPOEs Date: 05/05/2021 Electrical components tightening torque ¡IMPORTANTE! APLICAR TORQUE A COMPONENTES ENLISTADOS DE ACUERDO A LA TABLA. CONTINUA Component Cable # TAG Part Number Torque (in‐lb) TERMINAL BLOCK DOUBLE LEVEL GRAY, EATON TERMINAL BLOCK DOUBLE LEVEL GRAY, EATON PN XBUTT4 TERMINAL BLOCK DOUBLE LEVEL GRAY, EATON PN XBUTT4 RELAY, SPDT, 6MM RELAY AND SOCKET WITH INDICATOR LIGHT, 24 VAC/DC COIL, PN RV8H‐L‐AD24 RELAY, SPDT, 6MM RELAY AND SOCKET WITH INDICATOR LIGHT, 24 VAC/DC COIL, PN RV8H‐L‐AD24 GROUND BAR KIT, (1) 2/0 LUG, (5) 4‐14 AWG, .2 in X 4 in X 1 in EATON SERIES GBK GBK520 GROUND BAR KIT, (1) 2/0 LUG, (5) 4‐14 AWG, .2 in X 4 in X 1 in EATON SERIES GBK GBK520 DIRECT HANDLE R5 SERIES ROTARY DISCONNECT. EATON : DHR5 DIRECT HANDLE R5 SERIES ROTARY DISCONNECT. EATON : DHR5 14 TB‐120VAC XBUTT4 5 14 TB‐24VAC XBUTT4 5 14 S/S VFD1/VFD2 XBUTT4 5 14 FR‐1/FR‐3/FR‐11 XB3UKF25 3 14 R1 THRU R12 XB3UKF25 3 8 GROUND GBK520 25 10‐14 GROUND GBK520 20 14 XFMR‐2 Disc.Sw.CONTROLS R5 Series 18 14 XFMR‐3 Disc.Sw.LIGHTS R5 Series 18 R9L3200FJ 88 LFD55793Z 35 FUSED DISCONNECT SWITCH 200 amp, RATING, 3 POLE, 460V, L‐FRAME, EATON R9L3200FJ 1/0 DISTRIBUTION POWER BLOCK, 380 A, 3 POLE. LOAD 6 HOLES 2/0AWG ‐4AWG 14 PDB1 DISTRIBUTION POWER BLOCK, 380 A, 3 POLE. LINE 1 HOLE 500MCM‐4AWG, 1/0 PDB1 DISTRIBUTION POWER BLOCK, 760 A, LOAD 12 HOLES NUM 4 awg 8 PDB2 LFD55863Z 70 DISTRIBUTION POWER BLOCK, 760 A, LOAD 12 HOLES NUM 4 awg 14 PDB2 LFD55863Z 35 DISTRIBUTION POWER BLOCK, 760 A, 3 POLE LINE 2 HOLES NUM 500MCM‐4 awg 1/0 PDB2 LFD55863Z 115 DISTRIBUTION POWER BLOCK, 175A, 3 POLE LINE, LOAD 4‐14, 4 HOLES, 1/8 in HEX LUG 14 PDB3 LFS25702Z 35 SHEET NOTES 8 PDB3 LFS25702Z 70 KEY PLAN 14 XFMR‐1 L60030M‐3SQ 20 20 115 DISTRIBUTION POWER BLOCK, 175A, 3 POLE LINE,2/0‐14, 1 HOLE FUSE BLOCK, 3 POLE, CLASS L600M, MIDGET, 30 amp, 600V, LITTELFUSE, L60030M‐3SQ FUSE BLOCK, 3 POLE, CLASS L600M, MIDGET, 30 amp, 600V, LITTELFUSE, L60030M‐3SQ 14 XFMR‐2 L60030M‐3SQ FUSE BLOCK, 3 POLE, CLASS L600M, MIDGET, 30 amp, 600V, LITTELFUSE, L60030M‐3SQ 14 XFMR‐3 L60030M‐3SQ 20 14 SF‐1 LJ60030‐3CR. 25 14 SF‐2 LJ60030‐3CR. 25 FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. NORTH 1 2 3/2/2022 2:32:31 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 1/2" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. ¡IMPORTANTE! APLICAR TORQUE A COMPONENTES ENLISTADOS DE ACUERDO A LA TABLA. FINAL TABLA DE TORQUE DE COMPONENTES ELECTRICOS CL-3059-LH-BD-MP-3 FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. 14 SF‐3 LJ60030‐3CR. 25 14 SF‐4 LJ60030‐3CR. 25 14 SF‐5 LJ60030‐3CR. 25 14 SF‐6 LJ60030‐3CR. 25 14 SF‐7 LJ60030‐3CR. 25 14 SF‐8 LJ60030‐3CR. 25 14 SF‐9 LJ60030‐3CR. 25 14 SF‐10 LJ60030‐3CR. 25 14 SF‐11 LJ60030‐3CR. 25 14 SF‐12 LJ60030‐3CR. 25 14 CS‐SF 1 H809 4 14 CS‐SF 2 H809 4 14 CS‐SF 3 H809 4 14 CS‐SF 4 H809 4 14 CS‐SF 5 H809 4 14 CS‐SF 6 H809 4 14 CS‐SF 7 H809 4 14 CS‐SF 8 H809 4 14 CS‐SF 9 H809 4 14 CS‐SF 10 H809 4 FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. FUSE BLOCK 3 POLE CLASS J, 30 amp, 600V, EMPIRE LJ60030‐3CR. CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, CURRENT MONITOR FOR ECM SERIES FOR EC MOTORS, SERIES H6ECM, AMPERAGE RANGE 0.5 TO 17A CONTINUOUS, 14 CS‐SF 11 H809 4 14 CS‐SF 12 H809 4 GROUND BAR KIT, 14 TERMINAL, 2/0 LUG, LENGTH 6.74 in, 171.2 mm, EATON, GBK1420 10‐14 GROUND GBK1420 20 GROUND HUB 1‐1/4 IN, EATON, STG4 8 GROUND STG4 25 PAGE 3 OF 47 SHEET NOTES KEY PLAN NORTH 1 2 3/2/2022 2:32:31 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 1/2" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-4 DETALLE DE SUJECION DE CONDUITS PAGE 4 OF 47 ¡IMPORTANTE! USE TUERCA CON SEGURO DE NYLON EN TODOS LOS CLAMPS EN RIEL UNICANAL(STRUT) QUE SUJETAN LA TUBERIA ELECTRICA. SKU08116: NYLON INSERT LOCKNUT 1/4 in-20, GRADE 5, ZINC PLATED STEEL 2 ASSEMBLY SHEET NOTES KEY PLAN NORTH 1 1 FINAL 2 3/2/2022 2:32:33 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 02/22/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-5 SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES DETALLE DE SKUs SKU09131, SKU03132, SKU09133 Y SKU09134 SKU09131 STRUT CLAMP, 1/2 in, EMT AND RIGID, STEEL, CLAMP MATERIAL 304 S.S. ea 38 SKU09132 STRUT CLAMP, 3/4 in, EMT AND RIGID, STEEL, CLAMP MATERIAL 304 S.S. ea 10 SKU09133 STRUT CLAMP, 1 in, EMT AND RIGID, STEEL, CLAMP MATERIAL 304 S.S. ea 10 SKU09134 STRUT CLAMP, 1‐1/4 in, EMT AND RIGID, STEEL, CLAMP MATERIAL 304 S.S. ea 10 ea 20 ea 12 ea 13 ea 29 ea 19 ea 18 ea 1 ea 1 ea 2 SKU10546 SKU10547 SKU10548 SKU10549 SKU10550 SKU10554 SKU10555 SKU10557 CONDUIT WITH HANGER WITH BOLT 1/2 in ea 12 SKU04476 CONDUIT WITH HANGER WITH BOLT 3/4 in THREADED ROD HANGER HAMMER‐ON FLANGE CLIP BOTTOM MOUNT,THICKNESS 5/16in‐1/2 in,MANUFACTURER P/N: M58 ea 12 ea 4 ea 5 SKU10559 EMT TWO HOLE STRAP 1 in, 304S.S. SKU10546, SKU10549 EMT ONE HOLE STRAP 1/2 in, 304S.S. ea 30 SKU09129 EMT ONE HOLE STRAP 3/4 in, 304S.S. ea 30 SKU09575 EMT ONE HOLE STRAP 1 in, 304S.S. ea 10 SKU10635 2-GANG VERTICAL MOUNT WHILE IN USE COVER 3.5 IN DEPTH, WEATHERPROOF, METALLIC GRAY 1-GANG WEATHER PROOF IN USE COVER , ALUMINUM CONSTRUCTION , TAYMAC P/N: MX3200 ea 1 ea 6 CLAMP DE STAINLESS STEEL 1'' DE DOS CEJAS PARA COLOCAR EN EL AREA HUMEDA INDICADA EN PAG. 9 ¡IMPORTANTE! ASEGURARSE QUE CONECTOR CONTENGA BUSHING DE PLASTICO SKU10547, SKU10550 Y SKU10555 SKU09127, SKU09129 Y SKU09575 CLAMP DE STAINLESS STEEL 1'' DE UNA CEJA PARA COLOCAR EN EL AREA HUMEDA INDICADA EN PAG. 9 ¡IMPORTANTE! ASEGURARSE QUE CONECTOR CONTENGA BUSHING DE PLASTICO VER DETALLE 2 DE PAG 19 PARA INDICACIONES DE IN-USE COVERS EN GFCI SHEET NOTES KEY PLAN CONECTOR A 90 GRADOS PARA TUBO FLEXIBLE. (DIFERENTES DIAMETROS) USAR SEGUN TAMAÑO DE TUBERIA. IN‐USE COVER SKU04287 SKU09576 CONECTOR A 45 GRADOS PARA TUBO FLEXIBLE. (DIFERENTES DIAMETROS) USAR SEGUN TAMAÑO DE TUBERIA. EMT ONE HOLE STRAP S/S SKU09127 ABRAZADERA PARA VIGA. UTILIZAR EXCLUSIVAMENTE PARA CODUIT FLEXIBLE DE EXHAUST FANS. VER DETALLE DE INSTALACION EN PAG. 23 ¡IMPORTANTE! ASEGURARSE QUE CONECTOR CONTENGA BUSHING DE PLASTICO EMT TWO HOLE STRAP S/S SKU09576 SKU10559 CONECTOR RECTO PARA TUBO FLEXIBLE. (DIFERENTES DIAMETROS) USAR SEGUN TAMAÑO DE TUBERIA. CONDUIT WITH HANGER WITH BOLT SKU04475 ABRAZADERA PARA CONDUIT CON TORNILLO DE SUJECION. UTILIZAR EXCLUSIVAMENTE PARA CONDUIT FLEXIBLE DE EXHAUST FANS. VER DETALLE DE INSTALACION EN PAG. 23 SKU10545, SKU10548, SKU10554 Y SKU10557 FLEXIBLE METAL CONDUIT FLEXIBLE METAL CONDUIT, AC/MC/FMC STRAIGHT CONNECTOR 3/8 in, STEEL /ZINC, EATON, ACB38 FLEXIBLE METAL CONDUIT , AC/MC/FMC ELBOW 3/8 in X 45 deg, MALLEABLE IRON, EATON, ACB3845 FLEXIBLE METAL CONDUIT , AC/MC/FMC ELBOW 3/8 in X 90 deg, MALLEABLE IRON, EATON, ACB3890 FLEXIBLE METAL CONDUIT, AC/MC/FMC STRAIGHT CONNECTOR 1/2 in, STEEL /ZINC, EATON, ACB50 FLEXIBLE METAL CONDUIT , AC/MC/FMC ELBOW 1/2 in X 45 deg, MALLEABLE IRON, EATON, ACB5045 FLEXIBLE METAL CONDUIT , AC/MC/FMC ELBOW 1/2 in X 90 deg, MALLEABLE IRON, EATON, ACB5090 FLEXIBLE METAL CONDUIT , AC/MC/FMC STRAIGHT CONNECTOR 1 in, STEEL /ZINC, EATON, ACB100 FLEXIBLE METAL CONDUIT , AC/MC/FMC ELBOW 1 in X 90 deg, MALLEABLE IRON, EATON, ACB10090 FLEXIBLE METAL CONDUIT , AC/MC/FMC STRAIGHT CONNECTOR 1‐1/2 in, STEEL /ZINC, EATON, ACB150 SKU04475, SKU06239 CLAMPS DE STAINLESS STEEL PARA SUJECION DE TUBERIA EN STRUTS. SOLO UTILIZAR EN EL AREA HUMEDA INDICADA EN PAG. 9 UNIVERSAL STRUT CLAMP, S/S SKU10545 PAGE 5 OF 47 NORTH 1 2 3/2/2022 2:06:17 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 6" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-6 CONDULET SKU04423 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, LL, 1 in SKU04430 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, LR, 1 in SKU04442 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 1‐1/4 in SKU04445 SKU04446 SKU04447 SKU04448 SKU04449 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 1‐1/2 in THREADED CONDUIT BODY, LB, 1/2 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 3/4 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 1 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 1‐1/4 in, WITH COVER AND GASKET, EPOXY COATED SKU04452 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 2 in SKU04465 EMT ONE HOLE STRAP 1/2 in SKU04466 EMT ONE HOLE STRAP 3/4 in SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES DETALLE DE SKUs SKU04423 PAGE 6 OF 47 SKU04475, SKU04476 STRUT CLAMP PARA COLOCAR EN STRUTS EN AREA SECA CONDULET TIPO "LL" DE ALUMINIO 1 in. PARA CONDUITS EN ZONA SECA STRAPS Y HANGERS SKU04430 SKU04467 EMT ONE HOLE STRAP 1 in SKU04468 EMT ONE HOLE STRAP 1‐1/4 in SKU04469 EMT ONE HOLE STRAP 1‐1/2 in SKU04475 CONDUIT WITH HANGER WITH BOLT 1/2 in SKU04476 CONDUIT WITH HANGER WITH BOLT 3/4 in SKU04480 SKU04582 FLEXIBLE METAL CONDUIT , FMC, ONE HOLE STRAP 3/8 in UNIVERSAL STRUT CLAMP, 1/2 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2101 SKU04583 SKU04584 SKU04585 UNIVERSAL STRUT CLAMP, 3/4 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2102 UNIVERSAL STRUT CLAMP, 1 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2103 UNIVERSAL STRUT CLAMP, 1‐1/4 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2104 SKU04586 UNIVERSAL STRUT CLAMP, 1‐1/2 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2105 SKU04665 STRUT CHANNEL SOLID, 1‐5/8 in X 1‐5/8 in, TYPE 304 SS, 20 ft LENGTH SKU04666 SKU04657 STRUT CHANNEL SOLID, 13/16 in X 1‐5/8 in, TYPE 304 SS, 10 ft LENGTH GALVANIZED, STEEL STRUT CHANNEL SOLID, 13/16 in X 1‐5/8 in, 10 FT. LENGTH SKU01786 SLOTTED SUPERSTRUT CHANNEL 1‐5/8 in X 1‐5/8 in X 20 ft GALVANIZED CONDULET TIPO "LR" DE ALUMINIO 1 in. PARA CONDUITS EN ZONA SECA LIQ‐TIGHT, ELBOW, 1/2 in, WITH INSULATED THROAT SKU04349 SKU04350 SKU04351 SKU04354 LIQ‐TIGHT, ELBOW, 1/2 in X 45 deg WITH INSULATED THROAT FLEXIBLE METAL CONDUIT , FMC, ELBOW 1/2 in X 90 deg, MALLEABLE IRON FLEXIBLE METAL CONDUIT , FMC, ELBOW 1/2 in X 45 deg, MALLEABLE IRON FLEXIBLE METAL CONDUIT , FMC, ELBOW 3/8 in X 90 deg, MALLEABLE IRON SKU04355 FLEXIBLE METAL CONDUIT , FMC, ELBOW 3/8 in X 45 deg STRUT DE 1-5/8 in GALVANIZADO PARA SOPORTE DE TUBERIAS EN AREA SECA SKU04442, SKU04445 & SKU04452 SKU04657 STRUT DE 13/16 in GALVANIZADO PARA SOPORTE DE TUBERIAS EN AREA SECA CONDULET TIPO "SLB" DE ALUMINIO DE 1-1/4 in, 1-1/2 in Y 2 in PARA CONDUITS EN ZONA SECA FMC SKU04348 SKU01786 SKU04446, SKU04447, SKU04448 & SKU04449 J‐BOX SKU04827 J‐BOX, 8X8X4 in, OUTDOOR, NO KNOCKOUTS SKU04832 SKU04833 J‐BOX, 6.25X6.25X4 ALUMINUM DIE CAST, TYPE RATING 4, 4X, 6, 6P AND IP‐68, PN 1550Z139 J‐BOX, 4.76X4.76X4 ALUMINUM DIE CAST, TYPE RATING 4, 4X, 6, 6P AND IP‐68, PN 1550Z137 SKU04835 J‐BOX, 6X6X4 in, INDOOR, NO KNOCKOUTS SKU04836 J‐BOX, 8X8X6 in, INDOOR, NO KNOCKOUTS SKU04838 J‐BOX, 8X8X4 in, INDOOR, NO KNOCKOUTS SKU04842 J‐BOX, 10X10X6 in, INDOOR, NO KNOCKOUTS SKU04850 J‐BOX, 12X12X8 in, INDOOR, NO KNOCKOUTS SKU04855 BOX 4X4X 2‐1/8 D GALVANIZED SKU04348 CONECTOR PARA LIQUID TIGHT DE 90 GRADOS CON BUSHING CONDULET TIPO "LB" DE ALUMINIO 1 in. PARA CONDUITS EN ZONA SECA SHEET NOTES KEY PLAN SKU04465, SKU04466, SKU04467, SKU04468 & SKU04469 SKU04857 BOX COVER4X4 GALVANIZED SKU04281 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X2‐3/4X2 WITH 5 HOLES, 1/2 in, OUTLET SKU04282 SKU04283 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X2‐3/4X2 WITH 3, 1/2 in, OUTLET LIQ‐TIGHT, BOX COVER, 4‐1/2X 2‐3/4 in, EATON, VPN TP7292, CLOSE CELL SKU04284 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X 4‐1/2X2 WITH 3 HOLES, 1/2 in, OUTLET SKU04285 LIQ‐TIGHT, BOX COVER, 4‐1/2X 4‐1/2 in SKU04286 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X 4‐1/2X2 WITH 5 HOLES, 1/2 in, OUTLET SKU04349 CONECTOR PARA LIQUID TIGHT DE 45 GRADOS CON BUSHING CLAMP DE UNA CEJA PARA COLOCAR EN EL AREA SECA PARA CONDUITS DE DIFERENTES DIAMETROS SKU04298 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X4‐1/2X2 WITH 5 HOLES, 1/2 in, OUTLET SKU08011 J-BOX, 12X12X8 in, OUTDOOR TYPE 3R, NO KNOCKOUTS, HOFFMAN, A12R128NK NORTH 1 2 3/2/2022 2:32:34 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 6" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-7 CONDULET SKU04423 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, LL, 1 in SKU04430 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, LR, 1 in SKU04442 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 1‐1/4 in SKU04445 SKU04446 SKU04447 SKU04448 SKU04449 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 1‐1/2 in THREADED CONDUIT BODY, LB, 1/2 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 3/4 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 1 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 1‐1/4 in, WITH COVER AND GASKET, EPOXY COATED SKU04452 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 2 in SKU04465 EMT ONE HOLE STRAP 1/2 in SKU04466 EMT ONE HOLE STRAP 3/4 in SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES DETALLE DE SKUs SKU04350 & SKU04354 PAGE 7 OF 47 SKU04855 J-BOX 4X4X2-1/8 GALVANIZADA CON KNOCKOUTS PARA UTILIZAR EN AREA SECA FMC ELBOW DE 90 GRADOS PARA CONDUIT FLEXIBLES EN AREA SECA STRAPS Y HANGERS SKU04351 & SKU04355 SKU04467 EMT ONE HOLE STRAP 1 in SKU04468 EMT ONE HOLE STRAP 1‐1/4 in SKU04469 EMT ONE HOLE STRAP 1‐1/2 in SKU04475 CONDUIT WITH HANGER WITH BOLT 1/2 in SKU04476 CONDUIT WITH HANGER WITH BOLT 3/4 in SKU04480 SKU04582 FLEXIBLE METAL CONDUIT , FMC, ONE HOLE STRAP 3/8 in UNIVERSAL STRUT CLAMP, 1/2 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2101 SKU04583 SKU04584 SKU04585 UNIVERSAL STRUT CLAMP, 3/4 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2102 UNIVERSAL STRUT CLAMP, 1 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2103 UNIVERSAL STRUT CLAMP, 1‐1/4 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2104 SKU04586 UNIVERSAL STRUT CLAMP, 1‐1/2 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2105 SKU04665 STRUT CHANNEL SOLID, 1‐5/8 in X 1‐5/8 in, TYPE 304 SS, 20 ft LENGTH SKU04666 SKU04657 STRUT CHANNEL SOLID, 13/16 in X 1‐5/8 in, TYPE 304 SS, 10 ft LENGTH GALVANIZED, STEEL STRUT CHANNEL SOLID, 13/16 in X 1‐5/8 in, 10 FT. LENGTH SKU01786 SLOTTED SUPERSTRUT CHANNEL 1‐5/8 in X 1‐5/8 in X 20 ft GALVANIZED SKU04348 LIQ‐TIGHT, ELBOW, 1/2 in, WITH INSULATED THROAT SKU04349 SKU04350 SKU04351 SKU04354 LIQ‐TIGHT, ELBOW, 1/2 in X 45 deg WITH INSULATED THROAT FLEXIBLE METAL CONDUIT , FMC, ELBOW 1/2 in X 90 deg, MALLEABLE IRON FLEXIBLE METAL CONDUIT , FMC, ELBOW 1/2 in X 45 deg, MALLEABLE IRON FLEXIBLE METAL CONDUIT , FMC, ELBOW 3/8 in X 90 deg, MALLEABLE IRON SKU04355 FLEXIBLE METAL CONDUIT , FMC, ELBOW 3/8 in X 45 deg SKU04827 J‐BOX, 8X8X4 in, OUTDOOR, NO KNOCKOUTS SKU04832 SKU04833 J‐BOX, 6.25X6.25X4 ALUMINUM DIE CAST, TYPE RATING 4, 4X, 6, 6P AND IP‐68, PN 1550Z139 J‐BOX, 4.76X4.76X4 ALUMINUM DIE CAST, TYPE RATING 4, 4X, 6, 6P AND IP‐68, PN 1550Z137 SKU04835 J‐BOX, 6X6X4 in, INDOOR, NO KNOCKOUTS SKU04836 J‐BOX, 8X8X6 in, INDOOR, NO KNOCKOUTS SKU04838 J‐BOX, 8X8X4 in, INDOOR, NO KNOCKOUTS SKU04842 J‐BOX, 10X10X6 in, INDOOR, NO KNOCKOUTS SKU04850 J‐BOX, 12X12X8 in, INDOOR, NO KNOCKOUTS SKU04857 FMC ELBOW DE 45 GRADOS PARA CONDUIT FLEXIBLES EN AREA SECA COVER PARA J-BOX 4X4 GALVANIZADA PARA UTILIZAR EN AREA SECA SKU04827 SKU04281 J-BOX 8X8X4 NEMA 3R PARA USAR ENVALVULAS DE EXPANSION DE AREA HUMEDA FMC LIQUID TIGHT OUTLET BOX DE 4-1/2X2-3/4X2 DE 5 BARRENOS SKU04832 & SKU04833 J‐BOX SKU04282 LIQUID TIGHT OUTLET BOX DE 4-1/2X2-3/4X2 DE 3 BARRENOS J-BOX DE ALUMINIO PARA DIE CAST 6.25X6.25X4 Y 4.76X4.76X4 SHEET NOTES SKU04855 BOX 4X4X 2‐1/8 D GALVANIZED SKU04857 BOX COVER4X4 GALVANIZED SKU04281 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X2‐3/4X2 WITH 5 HOLES, 1/2 in, OUTLET SKU04282 SKU04283 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X2‐3/4X2 WITH 3, 1/2 in, OUTLET LIQ‐TIGHT, BOX COVER, 4‐1/2X 2‐3/4 in, EATON, VPN TP7292, CLOSE CELL SKU04284 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X 4‐1/2X2 WITH 3 HOLES, 1/2 in, OUTLET SKU04285 LIQ‐TIGHT, BOX COVER, 4‐1/2X 4‐1/2 in SKU04286 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X 4‐1/2X2 WITH 5 HOLES, 1/2 in, OUTLET KEY PLAN SKU04298 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X4‐1/2X2 WITH 5 HOLES, 1/2 in, OUTLET SKU08011 J-BOX, 12X12X8 in, OUTDOOR TYPE 3R, NO KNOCKOUTS, HOFFMAN, A12R128NK SKU04835, SKU04836, SKU04838, SKU04842 & SKU04850 SKU04283 J BOX SIN KNOCKOUTS PARA USAR EN AREA SECA OULET BOX COVER DE4-1/2X2-3/4 NORTH 1 2 3/2/2022 2:32:34 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 6" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-8 SKUS PARA ELEMENTOS DE CONEXION, SUJECION Y J-BOXES DETALLE DE SKUs PAGE 8 OF 47 SKU04284 CONDULET SKU04423 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, LL, 1 in SKU04430 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, LR, 1 in SKU04442 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 1‐1/4 in SKU04445 SKU04446 SKU04447 SKU04448 SKU04449 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 1‐1/2 in THREADED CONDUIT BODY, LB, 1/2 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 3/4 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 1 in, WITH COVER AND GASKET, EPOXY COATED THREADED CONDUIT BODY, LB, 1‐1/4 in, WITH COVER AND GASKET, EPOXY COATED SKU04452 SERVICE ENTRANCE ALUMINUM CONDUIT BODY, SLB, 2 in SKU04465 EMT ONE HOLE STRAP 1/2 in SKU04466 EMT ONE HOLE STRAP 3/4 in SKU04467 EMT ONE HOLE STRAP 1 in SKU04468 EMT ONE HOLE STRAP 1‐1/4 in SKU04469 EMT ONE HOLE STRAP 1‐1/2 in SKU04475 CONDUIT WITH HANGER WITH BOLT 1/2 in SKU04476 CONDUIT WITH HANGER WITH BOLT 3/4 in SKU04480 SKU04582 FLEXIBLE METAL CONDUIT , FMC, ONE HOLE STRAP 3/8 in UNIVERSAL STRUT CLAMP, 1/2 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2101 SKU04583 SKU04584 SKU04585 UNIVERSAL STRUT CLAMP, 3/4 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2102 UNIVERSAL STRUT CLAMP, 1 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2103 UNIVERSAL STRUT CLAMP, 1‐1/4 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2104 SKU04586 UNIVERSAL STRUT CLAMP, 1‐1/2 in, EMT AND RIGID, STEEL, ZINC PLATED, TOPAZ, 2105 SKU04665 STRUT CHANNEL SOLID, 1‐5/8 in X 1‐5/8 in, TYPE 304 SS, 20 ft LENGTH SKU04666 SKU04657 STRUT CHANNEL SOLID, 13/16 in X 1‐5/8 in, TYPE 304 SS, 10 ft LENGTH GALVANIZED, STEEL STRUT CHANNEL SOLID, 13/16 in X 1‐5/8 in, 10 FT. LENGTH SKU01786 SLOTTED SUPERSTRUT CHANNEL 1‐5/8 in X 1‐5/8 in X 20 ft GALVANIZED LIQUID TIGHT OUTLET BOX DE 4-1/2X4-1/2X2 DE 3 BARRENOS SKU04286 & SKU04298 STRAPS Y HANGERS LIQUID TIGHT OUTLET BOX DE 4-1/2X4-1/2X2 DE 5 BARRENOS SKU04285 LIQUID TIGHT OUTLET BOX COVER DE 4-1/2X4-1/2 FMC SKU04348 LIQ‐TIGHT, ELBOW, 1/2 in, WITH INSULATED THROAT SKU04349 SKU04350 SKU04351 SKU04354 LIQ‐TIGHT, ELBOW, 1/2 in X 45 deg WITH INSULATED THROAT FLEXIBLE METAL CONDUIT , FMC, ELBOW 1/2 in X 90 deg, MALLEABLE IRON FLEXIBLE METAL CONDUIT , FMC, ELBOW 1/2 in X 45 deg, MALLEABLE IRON FLEXIBLE METAL CONDUIT , FMC, ELBOW 3/8 in X 90 deg, MALLEABLE IRON SKU04355 FLEXIBLE METAL CONDUIT , FMC, ELBOW 3/8 in X 45 deg SKU08011 J‐BOX SKU04827 J‐BOX, 8X8X4 in, OUTDOOR, NO KNOCKOUTS SKU04832 SKU04833 J‐BOX, 6.25X6.25X4 ALUMINUM DIE CAST, TYPE RATING 4, 4X, 6, 6P AND IP‐68, PN 1550Z139 J‐BOX, 4.76X4.76X4 ALUMINUM DIE CAST, TYPE RATING 4, 4X, 6, 6P AND IP‐68, PN 1550Z137 SKU04835 J‐BOX, 6X6X4 in, INDOOR, NO KNOCKOUTS SKU04836 J‐BOX, 8X8X6 in, INDOOR, NO KNOCKOUTS SKU04838 J‐BOX, 8X8X4 in, INDOOR, NO KNOCKOUTS SKU04842 J‐BOX, 10X10X6 in, INDOOR, NO KNOCKOUTS SKU04850 J‐BOX, 12X12X8 in, INDOOR, NO KNOCKOUTS SKU04855 BOX 4X4X 2‐1/8 D GALVANIZED SKU04857 BOX COVER4X4 GALVANIZED SKU04281 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X2‐3/4X2 WITH 5 HOLES, 1/2 in, OUTLET SKU04282 SKU04283 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X2‐3/4X2 WITH 3, 1/2 in, OUTLET LIQ‐TIGHT, BOX COVER, 4‐1/2X 2‐3/4 in, EATON, VPN TP7292, CLOSE CELL SKU04284 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X 4‐1/2X2 WITH 3 HOLES, 1/2 in, OUTLET SKU04285 LIQ‐TIGHT, BOX COVER, 4‐1/2X 4‐1/2 in SKU04286 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X 4‐1/2X2 WITH 5 HOLES, 1/2 in, OUTLET SKU04298 LIQ‐TIGHT, OUTLET BOX, 4‐1/2X4‐1/2X2 WITH 5 HOLES, 1/2 in, OUTLET SKU08011 J-BOX, 12X12X8 in, OUTDOOR TYPE 3R, NO KNOCKOUTS, HOFFMAN, A12R128NK J-BOX 12X12X8 NEMA 3R NO KNOCKUTS PARA USAR EN AREA HUMEDA SHEET NOTES KEY PLAN NORTH 1 2 3/2/2022 2:32:35 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 6" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 SPLIT VER PAG. 32 PARA DETALLE DE SENSOR DE TEMPERATURA J.I.M. J.I.M. J.I.M. SPLIT 2 OVERHEAD CONDUIT LAYOUT PLAN VIEW CL-3059-LH-BD-MP-9 PAGE 9 OF 47 2 ¡IMPORTANTE! UTILIZAR CLAMPS 304 STAINLESS STEEL PARA TODOS LOS ELEMENTOS DE SUJECION DE "AREA HUMEDA'' CL-3059-LH-BD-MP-17 -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) VER PAG. 11 PARA DETALLE DE PARTE ALTA DE VESTIBULOS 1 CL-3059-LH-BD-MP-13 LEAK DETECTOR EXTERIOR SKU04832 6.25" x 6.25" x 4" SKU08011 12" x 12" x 8" EXV WIRING EMT: 1" SEÑALES EMT: 1/2" (SOBRE EL PISO) 1" SKU08011 12" x 12" x 8" PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL ACTUADOR (LEAK DETECTOR) CL-3059-LH-BD-MP-10 SEÑALES EMT: 3/4" ACTUADOR 2 SKU04855 4" x 4" x 2" SKU04833 4.76" x 4.76" x 4" SKU04833 4.76" x 4.76" x 4" -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS 1 SEÑALES EMT: 1 1/4" SEÑALES EMT: 3/4" (TEMPERATURE SENSOR) -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. 12" 3" USAR TUBERIA ROSCADA -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. FMC ACTUADOR 1 SEÑALES EMT: 3/4" PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL (LEAK DETECTOR) VER PAG. 33 (TYP.) SEÑALES EMT: 3/4" (SOBRE EL PISO) SSPP -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS SKU04850 12" x 12" x 8" (LEAK DETECTOR) LIGHTING EMT: 1/2" ACTUADOR 4 USAR IN-USE COVER PARA GCFI VER DETALLE DE 2 DE PAG. 19 (TYP) SEÑALES EMT: 3/4" FMC 1" ACTUADOR 3 SKU04855 4" x 4" x 2" 1 SKU04827 8" x 8" x 4" 1 3/2/2022 2:33:05 PM SKU04833 4.76" x 4.76" x 4" SKU04833 4.76" x 4.76" x 4" NORTH FIJAR COVER PARA SENSORES UTILIZANDO TORNILLO Y REMACHE REFERISE A LA PAGINA 4.1.131 DEL DIAGRAMA DE CONTROL PARA MODELO DE SENSOR se actualizo ubicacion SPLIT 2 CONDUIT LAYOUT PLAN VIEW 1/2" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 KEY PLAN 12" CL-3059-LH-BD-MP-16 SPLIT SHEET NOTES SKU04855 4" x 4" x 2" PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L 1 2 2 CL-3059-LH-BD-MP-11 PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. SPLIT J.I.M. J.I.M. J.I.M. 81" USAR TUBERIA ROSCADA 66" LIGHTINGEXV WIRING EMT: 1/2"EMT: 1" SEÑALES EMT: 1/2" ACTUADOR SEÑALES EMT: 3/4" SKU08011 12" x 12" x 8" SEÑALES EMT: 1 1/4" SEÑALES EMT: 3/4" SKU04835 6" x 6" x 4" (MOTOR RAIL) 11" 4 1/4" SEÑALES EMT: 1 1/2" -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS 42" 21 1/4" LIQUID TIGHT SEÑALES EMT: 1/2" VER PAG. 21 PARA DETALLE DE QUICK CONNECTORS 112 1/2" 124 1/2" 48" -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS SKU04842 10" x 10" x 6" SHEET NOTES 30" 40 1/4" LEAK DETECTOR EXTERIOR SKU04832 6.25" x 6.25" x 4" 15 1/2" LIGHTING EMT: 1/2" 82" 80" 82" SKU04833 4.5" x 4.5" x 2" GFCI -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. LIGHTING EMT: 1/2" 103" VER PAG. 32 -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO USAR IN-USE COVER PARA GCFI VER DETALLE DE 2 DE PAG. 19 (TYP) SEÑALES EMT: 3/4" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) SKU04850 12" x 12" x 8" SEÑALES EMT: 3/4" SEÑALES EMT: 1" SKU08011 12" x 12" x 8" SEÑALES EMT: 1 1/4" LIGHTING EMT: 1/2" PAGE 10 OF 47 ¡IMPORTANTE! UTILIZAR CLAMPS 304 STAINLESS STEEL PARA TODOS LOS ELEMENTOS DE SUJECION DE "AREA HUMEDA'' (VER DETALLE EN PAG. 9) SKU04833 4.76" x 4.76" x 4" LIGHTING EMT: 1/2" 63 1/2" 20 1/2" CL-3059-LH-BD-MP-10 112 1/2" 01/19/2021 02/07/2021 03/02/2021 SPLIT 2 PARED NORTE CONDUIT LAYOUT 29 1/2" NO. DATE 13 3/4" SMOKE DETECTOR JB KEY PLAN NORTH SKU04833 4.5" x 4.5" x 2" ACTUADOR 3/2/2022 2:33:27 PM PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL 1 VERIFIQUE QUE EL CABLE LD4 ESTE INSTALADO Y QUE HAYA 20 PIES DEL CABLE ENROLLADO 86 1/4" 1 2 SPLIT 2 PARED NORTE CONDUITS 1/2" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-11 PAGE 11 OF 47 SKU04850 12" x 12" x 8" LIGHTING EMT: 1/2" 15 3/4" 01/19/2021 02/07/2021 03/02/2021 SPLIT 2 PARED ESTE Y PARTE ALTA DE VESTIBULOS PLAN VIEW 6" 51 1/4" 48 1/2" XFMR 1 (150 VA) XFMR 2 (1.5 KVA) XFMR 3 - LIGHTS (3KVA) 45 1/4" SKU04855 4" x 4" x 2" LIGHTING EMT: 1/2" RIGID HIGH VOLTAGE EMPTY 3" 61 1/2" 37" 30 1/4" 27" VFD VENT EMT: 2" 16 1/2" SSPP VENT EMT: 1 1/2" 3" 4" BARRENOS EN PARTE ALTA DE VESTIBULO 1 1/2" (CONTROL VESTIBULE VENT) SEÑALES (RELAYS) EMT: 1" POWER EMT: 3/4" MODBUS EMT: 3/4" SEÑALES EMT: 1" SKU04855 4" x 4" x 2" SKU04836 8" x 8" x 6" VER PAG 19 & 20 PARA DETALLE DE INSTALACION DE CONDUITS CONTROLS EMPTY EMT: 1" ACTUADOR 2 LIGHTING EMT: 1/2" POWER (SUPPLY FANS) EMT: 1 1/4" 57" 9 1/2" LIFE SAFETY EMT: 1" SEÑALES EMT: 3/4" ACTUADOR 3 PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL 3/2/2022 2:33:33 PM SPLIT 2 PARED ESTE CONDUIT LAYOUT 1/2" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS 1 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: SHEET NOTES KEY PLAN NORTH SKU04855 4" x 4" x 2" 7" LIGHTING EMT: 1/2" 1 4" 2 -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS SKU04850 12" x 12" x 8" 20 1/2" 12" LIGHTING EMT: 1/2" -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. 6" 29" SKU04855 4" x 4" x 2" FMC 15 1/4" FMC SKU04855 4" x 4" x 2" 13 3/4" 16 1/2" 21 1/4" 36" FMC SEÑALES EMT: 1 1/2" 76 1/2" FMC 9 1/2" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) 2 SPLIT 2 VESTIBULOS PARTE ALTA 3/4" = 1'-0" 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 2 DETALLE DE VENTILACION Y CONDUITS VACIOS CL-3059-LH-BD-MP-12 PAGE 12 OF 47 CONTROLS EMPTY EMT: 1" 59" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) 50 1/2" 3" 3" 3" 29" 22 1/2" VER PAG. 19 & 20 PARA DETALLE DE INSTALACION DE CONDUITS EN EL TECHO 15 3/4" 12" -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS 10" RIGID HIGH VOLTAGE EMPTY 3" SKU04850 12" x 12" x 8" LIGHTING EMT: 1/2" SKU04850 12" x 12" x 8" SEÑALES EMT: 1 1/2" SKU04835 6" x 6" x 4" LIGHTING EMT: 1 1/2" -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO 29 1/2" SKU04855 4" x 4" x 2" LIFE SAFETY EMT: 1" -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. 1 1/2" (CONTROL VESTIBULE VENT) 2" (VFD VENT) 2" 3" -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. FMC 14" 2" CONTROL PANEL ABB 320 161 723 PX1 -2 W th io ut NEMA 1ULyTpe1 300 Ar ch ti cet rue R2 15 23 ACH5 80- P CR- 0 23A-4- 1 ABB ACH5 80- P CR-023A - 4-1- Arc hit ectur e 300 $TC.- $L O DDE ST.$LO D LEV EL. PackagedDrvi ewith Dis co nnect M a ens with rC i cu ti Br ea k er ACH5 80- P CR 3 80V / 480 V- 1 300 ACH5 80- P CR-023A - 4-1- Arc hit ectur e ABB 320 161 723 PX1 -2 W th io ut NEMA 1ULyTpe1 300 Ar ch ti e c t rue R2 15 23 ACH5 80- P CR- 0 23A-4- 1 ABB ACH5 80- P CR-023A - 4-1- Arc hit ectur e 300 $TC.- $L O DDE ST.$LO D LEV EL. PackagedDrvi ewith Dis co nnect M a ens with rC i cu ti Br ea k er ACH5 80- P CR 3 80V / 480 V- 1 ACH5 80- P CR-023A - 4-1- Arc hit ectur e 300 62 1/2" ABB ACH58 0- CP ABB ACH58 0- CP _cp $TC._cp ACH58 0- Co nt r o l Pa nel ACH58 0- Co nt r o l Pa nel ACH58 0- CP _cp ABB ACH58 0- CP ABB ACH58 0- CP _cp $TC._cp ACH58 0- Co nt r o l Pa nel ACH58 0- Co nt r o l Pa nel ACH58 0- CP _cp VFD 1 SSPP 1 1/2" (CONTROL VESTIBULE VENT) FMC 36" 5 3/4" -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS 54 1/2" VFD 2 3" SHEET NOTES 3" 1 1/2" VER PAG 18 PARA DETALLE DE LUCES PILOTO 3" 11" 3" KEY PLAN SKU04855 4" x 4" x 4" VER PAG. 1 Y 2 PARA TABLA DE TORQUE DE COMPONENTES 1 NORTH 2" (VFD VENT) 14" 1 2 DETALLE DE VESTIBULO DE VFD Y CONDUITS VACIOS 1/2" = 1'-0" 3/2/2022 2:33:37 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 2 PARED DE PRESION CONDUIT LAYOUT CL-3059-LH-BD-MP-13 PAGE 13 OF 47 VER PAG. 14 Y 15 PARA DETALLE DE CONEXION DE MODBUSY SEÑALES. TIPICO EN CADA ABANICO 41 3/4" 36 3/4" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) 35 1/4" 30 1/4" 32 1/4" RESPETAR ORDEN DE ABANICOS -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. POWER EMT: 3/4" SF-1 SF-2 SKU04835 6" x 6" x 4" MODBUS EMT: 3/4" SF-3 -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS SF-4 -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO SKU04835 6" x 6" x 4" SEÑALES EMT: 1" -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. MODBUS EMT: 3/4" SEÑALES EMT: 1" SEÑALES EMT: 1" SF-5 SF-6 SF SGN J-BOX SKU04835 6" x 6" x 4" SF-7 SEÑALES EMT: 1" 82" -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. SF-8 SKU04835 6" x 6" x 4" -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS SF-9 SF-10 SF-11 SF-12 39" 45 3/4" SKU04835 6" x 6" x 4" 49 1/2" 86 1/4" 92 3/4" MODBUS EMT: 3/4" POWER EMT: 1" SHEET NOTES POWER EMT: 1 1/4" MODBUS EMT: 3/4" KEY PLAN NORTH POWER (SUPPLY FANS) EMT: 1 1/4" 1 1 2 PARED DE PRESION DETALLE DE SUPPLY FANS 1/2" = 1'-0" 3/2/2022 2:33:42 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-16 26 1/4" 19" (MOTOR RAIL) 9" 12" CONTROL VENT EMT: 1 1/2" SEÑALES (RELAYS) EMT: 1" SEÑALES EMT: 3/4" SKU04833 4.76" x 4.76" x 4" VFD VENT EMT: 2" SEÑALES EMT: 3/4" 4 3/4" SSPP VENT EMT: 1 1/2" SKU04833 4.76" x 4.76" x 4" POWER EMT: 3/4" LIQUID TIGHT PRESSURE SENSING EMT: 1 1/4" POWER EMT: 3/4" SKU04855 4" x 4" x 2" 20 3/4" 17 1/4" SKU04827 8" x 8" x 4" -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS (GFCI) 65" LIGHTING EMT: 1/2" 55 1/2" POWER EMT: 3/4" EXV TERMINAL STRIP SKU04836 8" x 8" x 6" 48 1/4" 84" 82" POWER (SUPPLY FANS) EMT: 1 1/4" 51 1/2" SEÑALES EMT: 3/4" MODBUS EMT: 3/4" 48" SKU04835 6" x 6" x 4" -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. REVISAR TABLA DE TORQUE EN PAG 1 & 2 (GFCI) -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO EXV WIRING EMT: 1" LIGHTING EMT: 1/2" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS 42 3/4" SKU04833 4.76" x 4.76" x 4" USAR IN-USE COVER PARA GCFI VER DETALLE DE 2 DE PAG. 19 (TYP) LIGHTING EMT: 1/2" SEÑALES EMT: 1" SKU04855 4" x 4" x 2" 66" SKU04833 4.76" x 4.76" x 4" 46 1/2" 120" LIGHTING EMT: 1/2" SKU04855 4" x 4" x 2" 7" 82 1/4" PRESSURE SENSING EMT: 1 1/4" 5 1/4" PRESSURE SENSING EMT: 1 1/4" PRESSURE SENSING EMT: 1 1/4" SPLIT 89" 27 1/2" SKU04835 6" x 6" x 4" PAGE 16 OF 47 48" 01/19/2021 02/07/2021 03/02/2021 SPLIT 2 PARED SUR CONDUIT LAYOUT VER PAG. 21 PARA DETALLE DE QUICK CONNECTORS VER PAG. 18 PARA DETALLE DE CONEXIONES DE VALVULAS SHEET NOTES FMC KEY PLAN 23 1/2" SKU04855 4" x 4" x 2" 36" 16" 56" SKU04855 4" x 4" x 2" POWER (SUPPLY FANS) EMT: 1 1/4" SEÑALES EMT: 3/4" REFERISE A LA PAGINA 4.1.131 DEL DIAGRAMA DE CONTROL PARA MODELO DE SENSOR 1 3/2/2022 2:34:01 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 ¡IMPORTANTE! UTILIZAR CLAMPS 304 STAINLESS STEEL PARA TODOS LOS ELEMENTOS DE SUJECION DE "AREA HUMEDA'' (VER DETALLE EN PAG. 9) NORTH SPLIT 1 2 SPLIT 2 PARED SUR CONDUITS 1/2" = 1'-0" PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 2 PARTE TRASERA DE DX COIL CONDUIT LAYOUT CL-3059-LH-BD-MP-17 PAGE 17 OF 47 6 3/4" 5 SKU04835 6" x 6" x 4" SKU04833 4.76" x 4.76" x 4" -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. VER PAG.21 PARA DETALLE DE QUICK CONNECTORS LIQUID TIGHT LIQUID TIGHT SEÑALES EMT: 1/2" 4 1/4" SKU04835 4" x 4" x 2" 92" 80" 81" 84" -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO VER PAG. 36 PARA DETALLE DE UBICACIONES DE PRESSURE TIPS 20 1/4" COLOCAR BASE PARA J-BOXES -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS SKU04836 8" x 8" x 6" FMC SKU04833 4.76" x 4.76" x 4" -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. REFERIRSE AL DAMPER MATRIX PARA MODELO DE ACTUADOR LIGHTING EMT: 1/2" 10 1/2" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) 4 -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. SKU04855 4" x 4" x 2" -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS FMC 34" ACTUADOR SHEET NOTES KEY PLAN NORTH 2 SPLIT 2 DETALLE DE CONEXION DE JBOXES DE VALVULAS 1/2" = 1'-0" 1 SPLIT 2 PARTE TRASERA DE DX COIL 1/2" = 1'-0" 1 2 3/2/2022 2:34:15 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 2 DETALLE DE LUCES PILOTO Y CONEXIONES DEL COIL CL-3059-LH-BD-MP-18 PAGE 18 OF 47 EXV CONEXION A TABLETAS PARA UNIDADES AHU-BD & AHU-MP CONECTAR TERMINALES A VALVULAS CORRESPONDIENTES 1 7 2 8 5 CUBIERTA DE BLOQUE: XBACUTT4 6 -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO EV-JS-1-BLACK EV-JS-1-GREEN 4 -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. 6 7 8 EV-GS-1-RED 3 TERMINAL DE DOBLE NIVEL: XBUTT4 5 -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. EV-GS-2-RED TOPE DE EXTREMO: XBAES35C 2 EV-GS-1-WHITE 1 -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS EV-GS-2-WHITE INSTALAR JUMPERS COMO SE MUESTRA EV-GS-1-GREEN EF-2 4 EV-GS-2-GREEN EF-1 3 EV-GS-1-BLACK SF-10 SF-11 SF-12 TO COND.UNIT EXV-2 DRIVER EV-GS-2-BLACK SF-9 TO COND.UNIT EXV-1 DRIVER EV-JS-1-RED SF-7 SF-8 EV-JS-2-RED SF-6 EV-JS-1-WHITE SF-5 SSPP EV-JS-2-WHITE SF-3 SF-4 EV-JS-2-GREEN SF-2 EV-JS-2-BLACK SF-1 -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) 8'' X 8'' X 4'' J-BOX UBICADA EN SECCION DEL DX COIL SHEET NOTES KEY PLAN NORTH JS-SERIES GS-SERIES 1 1 LUCES PILOTO 1/2" = 1'-0" 2 2 DETALLE DE CONEXIONES 3/8" = 1'-0" 3/2/2022 2:34:21 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 2 DETALLES DE INSTALACION DE CONDUITS EN TECHO CL-3059-LH-BD-MP-19 PAGE 19 OF 47 SKU10635 11 1/2 6 21.06 1 GANG IN-USE COVER PARA GFCI. USAR EN UBICACIONES DONDE SOLO HAYA UN RECEPTACLE GFCI Access Door provided with stay chain to limit swing to 90° SKU04287 150 140 SHEET NOTES KEY PLAN 2 GANG IN-USE COVER PARA GFCI. USAR EN UBICACIONES DONDE HAYA UN RECEPTACLE GFCI Y UN LIGHT SWITCH NORTH 1 1 ROOF CONDUIT INSTALATION DETAILS 2 3/4" = 1'-0" 2 2 DETALLE DE COVER PARA GFCI 3" = 1'-0" 3/2/2022 2:34:25 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 2 DETALLES DE INSTALACION DE CONDUITS EN TECHO CL-3059-LH-BD-MP-20 PAGE 20 OF 47 CONTROLS EMPTY EMT: 1" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) Tipico Burbujas 41 & 42 LIFE SAFETY EMT: 1" Cap 1" SKU07762 Caulking around pipe 1" Rigid Conduit End treated 3 42 3 3 Touch Panel Screen at Access Door Recessed Insulation COVER ELECTRICO PARA CONDUITS VACIOS CONTROLS EMPTY EMT: 1" -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS 4 CL 68 7/8 7/8 (36'') 56.5 (64 1/2'') 4 1 LIFE SAFETY EMT: 1" (13 1/4'') CL COVER PARA CONDUIT VER PACK 5 PARA DIMENSIONES ASEGURECE DE INSTALAR OREJA DE TIERRA. SKU08938 LOCKNUT, GROUNDING, 3 IN (56 1/2'') 0 -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS Tubo Rigido, 3" Dia. SKU:SKU08137 HUB 3" Dia. SKU08382 1" Rigid conduit SKU04551 HUB 1 Hub-1in in CHB SERIES Hacer Cuerda a ambos lados Contra Tuerca 43 22.5 3 -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. 34 59 41 Instale Tapon de plastico. SKU:SKU07257 64 1/2 SHEET NOTES KEY PLAN 10 COVER PARA CONDUIT VER PACK 5 PARA DIMENSIONES 136 SIDE VIEW NORTH 1 3/2/2022 2:34:30 PM 3 ROOF CONDUIT INSTALATION DETAILS 3 3/4" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 2 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 2 COVER ELECTRICO PARA CONDUITS VACIOS ENSAMBLE 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 1 CONDUIT LAYOUT PLAN VIEW CL-3059-LH-BD-MP-22 PAGE 22 OF 47 SKU04836 8" x 8" x 6" FILTER GAUGE COVER PROVIDED BY MFG. SKU04836 8" x 8" x 6" SKU04855 4" x 4" x 2" (GFCI) 8 3/4" 35 1/4" CL-3059-LH-BD-MP-24 SEÑALES EMT: 3/4" SKU04833 4.76" x 4.76" x 4" SKU04835 6" x 6" x 4" ACTUADOR LIGHTING EMT: 1/2" -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO SEÑALES EMT: 3/4" -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. CL-3059-LH-BD-MP-29 8 3/4" 28 3/4" FMC 1 -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS SEÑALES EMT: 1" FMC SEÑALES EMT: 3/4" SPLIT -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. SKU04833 4.76" x 4.76" x 4" 1 -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) ACTUADOR ACTUADOR PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX SKU04833 4.76" x 4.76" x 4" SKU04833 4.76" x 4.76" x 4" SKU04833 4.76" x 4.76" x 4" ¡IMPORTANTE! SEÑALES EMT: 3/4" COLOCAR CLAMPS EN TODOS LOS FLEXIBLES QUE VAN ENTRE SPLITS. FIJAR COVER PARA SENSORES UTILIZANDO TORNILLO Y REMACHE -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS (GFCI) 1 SHEET NOTES CL-3059-LH-BD-MP-25 KEY PLAN SKU04855 4" x 4" x 2" 1 CL-3059-LH-BD-MP-28 1 3/2/2022 2:34:54 PM REFERISE A LA PAGINA 4.1.131 DEL DIAGRAMA DE CONTROL PARA MODELO DE SENSOR SKU04855 4" x 4" x 2" SKU04855 4" x 4" x 2" SKU04835 6" x 6" x 4" NORTH SPLIT 1 1 CL-3059-LH-BD-MP-S8 CL-3059-LH-BD-MP-17 2 1 1 CL-3059-LH-BD-MP-27 CL-3059-LH-BD-MP-27 CL-3059-LH-BD-MP-26 2 SPLIT 1 CONDUIT LAYOUT PLAN VIEW 1/2" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. DETALLE DE SUJECION DE CADDY CAMPS CL-3059-LH-BD-MP-23 PAGE 23 OF 47 BEAM CLAMPS MONTADOS EN BRAZO DIAGONAL DE DE ABANICO FLEXIBLE CONDUIT 1 DETALLE DE SUJECION DE EF CONDUIT FLEXIBLE INSTALACION 2 DETALLE DE INSTALACION DE CADDY CLAMP SECTION 3/4" = 1'-0" SKU10559 SKU04475 & SKU06239 AX 36'' M AX 36'' M SHEET NOTES SUJECION DE TUBO FLEXIBLE KEY PLAN NORTH SKU04855 4" x 4" x 2" CL-3059-LH-BD-MP-S15 3 3/2/2022 2:35:03 PM 1 SKU04855 4" x 4" x 2" 5 CADDY CLAMPS FLOOR PLAN 3/4" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 4 2 DETALLE DE SUJECION DE EF CONDUIT FLEXIBLE PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 3/4" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 1 PARED NORTE CONDUIT LAYOUT CL-3059-LH-BD-MP-24 PAGE 24 OF 47 SPLIT PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL SKU04836 8" x 8" x 6" SKU04833 4.76" x 4.76" x 4" 35 1/4" 30 1/2" 13 1/2" 15" ¡IMPORTANTE! LIGHTING EMT: 1/2" ACTUADOR SEÑALES EMT: 1" IMPORTANTE LIGHTING EMT: 1/2" COLOCAR SINCHOS A PARA ASEGUARA LA BASE DEL ACTUADOR CON EL ACTUADOR SKU04836 8" x 8" x 6" FMC 2 1/2" SKU04835 6" x 6" x 4" LIGHTING EMT: 1/2" FILTER GAUGE COVER PROVIDED BY MFG. VER PAG. 21 PARA DETALLE DE QUICK CONNECTORS SKU04835 6" x 6" x 4" SEÑALES EMT: 1/2" (GFCI) -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS SEÑALES EMT: 1/2" VER PAG. 30 60" USAR IN USE COVER PARA GFCI VER DETALLE 2 DE PAG. 19 (TYP) 48" -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. 80" 36" 82" -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. 100 1/4" SKU04855 4" x 4" x 2" -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO LIGHTING EMT: 1/2" FMC -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. 34" REFERIRSE AL DAMPER MATRIX PARA MODELO DE ACTUADOR COLOCAR CLAMPS EN TODOS LOS FLEXIBLES QUE VAN ENTRE SPLITS. 112" ACTUADOR -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) SKU04835 4" x 4" x 2" SHEET NOTES KEY PLAN NORTH ACTUADOR SPLIT 1 1 2 SPLIT 1 PARED NORTE CONDUIT LAYOUT 1/2" = 1'-0" 3/2/2022 2:35:08 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 1 PARED SUR CONDUIT LAYOUT CL-3059-LH-BD-MP-25 35 1/2" PAGE 25 OF 47 63" 34 1/4" 15 1/4" SEÑALES EMT: 3/4" FMC 7 1/4" 30" POWER EMT: 3/4" 119 3/4" 23" 46" SEÑALES EMT: 3/4" SKU04855 4" x 4" x 2" SKU04835 6" x 6" x 4" SKU04855 4" x 4" x 2" LIGHTING EMT: 1/2" SEÑALES EMT: 3/4" -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. (GFCI) 25 3/4" SKU04855 4" x 4" x 2" -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS SHEET NOTES 7" 26" SKU04835 6" x 6" x 4" 22 3/4" 48" 48" USAR IN-USE COVER PARA GCFI VER DETALLE DE 2 DE PAG. 19 (TYP) -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. VER DETALLE EN PAG. 23 PARA SUJECION DE TUBO FLEXIBLE VER PAG. 21 PARA DETALLE DE QUICK CONNECTORS 79" 71-1/2" (GFCI) 60" 73 1/4" 80" 92 1/4" 82" 16" SEÑALES EMT: 3/4" -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO SKU04855 4" x 4" x 2" VER PAG. 31 VAISALA SENSOR -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS SKU04835 6" x 6" x 4" LIGHTING EMT: 1/2" SKU04855 4" x 4" x 2" VER PAG. 36 PARA UBICACION 77" 10 1/2" SPLIT ¡IMPORTANTE! COLOCAR CLAMPS EN TODOS LOS FLEXIBLES QUE VAN ENTRE SPLITS -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) 1 28 1/2" 75 " PRESSURE SENSING EMT: 1 1/4" KEY PLAN NORTH (TEMPERATURE SENSOR) SPLIT 1 3/2/2022 2:35:10 PM VER. PAG 27 PARA DETALLE DE INSTALACION REFERISE A LA PAGINA 4.1.131 DEL DIAGRAMA DE CONTROL PARA MODELO DE SENSOR 1 16" 2 35 1/2" SPLIT 1 PARED SUR CONDUIT LAYOUT 1/2" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 1 AREA DE TRANSMITTER CONDUIT LAYOUT CL-3059-LH-BD-MP-26 VER PAG. 36 PAGE 26 OF 47 LIGHTING EMT: 1/2" 5 -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. 4 SKU04836 8" x 8" x 6" -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS 6 -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO SKU04835 6" x 6" x 4" VER PAG. 21 PARA DETALLE DE QUICK CONNECTORS -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. VAISALA SENSOR (HUMIDITY SENSOR) 112" SKU04835 6" x 6" x 4" -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS REFERISE A LA PAGINA 4.1.131 DEL DIAGRAMA DE CONTROL PARA MODELO DE SENSOR 26" 21" SEÑALES EMT: 3/4" 60" (TEMPERATURE SENSOR) SHEET NOTES KEY PLAN NORTH VER PAG. 31 PARA DETALLE DE INSTALACION DE SENSOR DE TEMPERATURA 1 3/2/2022 2:35:13 PM 1 2 SPLIT 1 SOPORTES DE SENSOR DE TEMPERATURA 1/2" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. SPLIT 1 PARED ENTRADA DE EXHAUST FAN CONDUIT LAYOUT CL-3059-LH-BD-MP-27 PAGE 27 OF 47 -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) VER PAG. 36 -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. SEÑALES EMT: 3/4" -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS 3 2 SEÑALES EMT: 3/4" 25 1/2" LIGHTING EMT: 1/2" SKU04855 4" x 4" x 2" SEÑALES EMT: 3/4" -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO 27 1/2" -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. SKU04855 4" x 4" x 2" LIGHTING EMT: 1/2" -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. LIGHTING EMT: 1/2" 25 3/4" 77 1/4" 72" 80" 82" 70" 92 1/4" SKU04855 4" x 4" x 2" -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS SHEET NOTES KEY PLAN NORTH 1 SPLIT 1 PARED ENTRADA DE EXHAUST FAN 1/2" = 1'-0" 2 SPLIT 1 PARED ENTRADA DE EXHAUST FAN INTERIOR 1/2" = 1'-0" 1 2 3/2/2022 2:35:18 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-28 SPLIT 1 PARED OESTE CONDUIT LAYOUT PAGE 28 OF 47 -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. (MOTOR RAIL) -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS ACTUADOR -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. VER PAG. 34 Y 35 PARA DETALLE DE POSICION DE ACTUADORES -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS IMPORTANTE COLOCAR SINCHOS A PARA ASEGURAR LA BASE CON EL ACTUADOR VER PAG. 45 Y 46 PARA DETALLE DE CONEXION DE ACTUADORES SHEET NOTES KEY PLAN NORTH 1 1 SPLIT 1 PARED OESTE CONDUIT LAYOUT 1/2" = 1'-0" 2 3/2/2022 2:35:18 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-29 SPLIT 1 PARED PARED DE DAMPERS EXHAUST AIR CONDUIT LAYOUT PAGE 29 OF 47 (3) SKU04833 4.76" x 4.76" x 4" SKU04835 6" x 6" x 4" 35 1/4" 1 1/4" VER PAG. 36 SEÑALES EMT: 3/4" SEÑALES EMT: 3/4" SEÑALES EMT: 3/4" 78 3/4" ACTUADOR 40 3/4" 2" SKU04833 4.76" x 4.76" x 4" SKU04833 4.76" x 4.76" x 4" FMC FMC VER PAG. 34 Y 35 PARA DETALLE DE POSICION DE ACTUADORES SKU04833 4.76" x 4.76" x 4" PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL FMC ACTUADOR 80" SEÑALES EMT: 3/4" PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL SHEET NOTES KEY PLAN NORTH 1 SPLIT 1 PARED DE DAMPERS EXHAUST AIR CONDUIT LAYOUT 1/2" = 1'-0" 1 2 3/2/2022 2:35:24 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 1/2" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. DETALLE DE FILTER GAUGE PAGE 30 OF 47 CL-3059-LH-BD-MP-30 HACER 2 VECES Straig brass adapter, SKU08405 Brass elbow adapter, SKU08404 DWYE R I NST RUM ENT S, INC. M ICH . CITY , I N. U. S . A. ZERO SET LINE NT VE VE NT F OF F OF LINE Copper Lines (only in the outside) SKU03987, Vent Valves x 2 Filter Gauge W/ signal flag, SKU08360 Filter Gauge support Multiplastic round clamp, SKU08407 SHEET NOTES KEY PLAN NORTH LEFHT HAND UNIT TAGS 5.MPOE1.AHU.02 5.MPOE2.AHU.01 1 1 2 FILTER GAUGE 1/2" = 1'-0" 3/2/2022 2:35:29 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 1/2" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-31 DETALLE DE INSTALACION DE VAISALA SENSOR PAGE 31 OF 47 HACER 2 VECES GASKET NEOPRENO 1/4" COMPRIMIDO BRACKET P/ENVIO VAISALA 5/8 GASKET NEOPRENO 1/4" BRACKET P/ENVIO 13/16 VAISALA BRACKET P/ENVIO SHEET NOTES 4 1/2 KEY PLAN NORTH LEFHT HAND UNIT TAGS 5.MPOE1.AHU.02 5.MPOE2.AHU.01 1 3/2/2022 2:35:29 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 1 2 VISTA AUXILIAR 1 1/2" = 1'-0" PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 1/2" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 HAT CHANNEL J.I.M. J.I.M. J.I.M. DETALLE SENSOR DE TEMPERATURA DE DX COIL Y TRANSMITTER CL-3059-LH-BD-MP-32 PAGE 32 OF 47 10 HAT CHANNEL PAIRED TRANMITTER / AVERAGING (NUMERO DE PARTE-SKU05135) CANAL 10 3/4 1 1/4 SOPORTE 10 3/4 SOPORTE 10 3/4 18 1/2 10 3/4 INSTALAR HAT CHANNEL ATORNILLADO AL FRAME DEL COOIL Y AGARRADO AL SOPORTE DEL QUE BIENE DE FABRICA PAIRED TRANMITTER / AVERAGING (NUMERO DE PARTE-SKU05136) CANAL 10 3/4 7 1/2 DOOR 10 3/4 140 18 1/4 10 3/4 22 7/16 10 3/4 71 3/4 22 7/16 10 3/4 18 1/2 SOPORTE PARA BELL BOX 10 3/4 22 7/16 21 AL SOPORTE 101 SHEET NOTES 12 1/8 14 1/2 KEY PLAN NORTH 48 3/16 2 SOPORTE PARA BELL BOX AL ANGULO 136 1 PARTE DE DX COIL 3/4" = 1'-0" 2 1 2 PARTE DE TRANSMITTER 3/4" = 1'-0" 3/2/2022 2:35:30 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: 3/4" = 1'-0" Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-33 DETALLE DE INSTALACION DE LEAK DETECTOR PAGE 33 OF 47 HACER 2 VECES INSTALA GUARDA PARA LEAK DETECTOR (VER RANURA PARA TUBERIA) LD RANURA PARA TUBERIA ELECTRICA 60 1/4" PUNTEA HAT CHANNEL AL PISO (Según lo requiera la ranura para la tubería eléctrica) LEAK DETECTOR (POR DENTRO (LEAK DETECTOR) 3" INSTALAR GASKET DE MARCO DE PUERTA EN ESTE LADO. SKU03540:EDGE-GRIP RUBBER SEAL BULB (LEAK DETECTOR) (LEAK DETECTOR) SHEET NOTES LEFHT HAND UNIT TAGS 5.MPOE1.AHU.02 5.MPOE2.AHU.01 REV.1 DESPINOZA 05/12/2021 KEY PLAN 34 3/4" 1 VISTA AUXILIAR 3 1/2" = 1'-0" 2 NORTH 60 1/4" DETALLE DE POSICION DE LEAK DETECTORS 1/4" = 1'-0" 1 2 3/2/2022 2:35:56 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 O RO J.I.M. J.I.M. J.I.M. DETALLES DE POSICION DE ACTUADORES CL-3059-LH-BD-MP-34 F SEÑALES EMT: 3/4" MIX ACTUADOR DE A VER PAG. 45 Y 46 PARA DETALLE DE CONEXION DE ACTUADORES IR W ALL ED A SEÑALES EMT: 3/4" SKU04833 4.76" x 4.76" x 4" OU T SI PAGE 34 OF 47 IR W ALL VER PAG. 47 PARA DETALLE DE CONEXION DE ACTUADORES ACTUADOR SEÑALES EMT: 3/4" SKU04833 4.76" x 4.76" x 4" IMPORTANTE COLOCAR SINCHOS A PARA ASEGUARA LA BASE DEL ACTUADOR CON EL ACTUADOR ACTUADOR 1 ACTUADOR REFERIRSE AL DAMPER MATRIX PARA MODELO DE ACTUADOR OSA DAMP ACTUATOR POS ACTUADOR 1 REFERIRSE AL DAMPER MATRIX PARA MODELO DE ACTUADOR WA LK SA F ING AN SID E GR AT I 2 NG MA DAMP ACTUATOR POS SKU04855 PO 4" x 4" x 2" WE RV EST IB U LE SEÑALES EMT: 1" SKU04855 4" x 4" x 2" ACTUADOR 2 VER PAG. 33 PARA DETALLE DE CONEXION DE ACTUADORES VER PAG. 43 PARA DETALLE DE CONEXION DE ACTUADORES SKU04855 4" x 4" x 2" CO NTR OL VES TIB ULE SEÑALES EMT: 3/4" ACTUADOR 4 SHEET NOTES KEY PLAN SKU04855 4" x 4" x 2" REFERIRSE AL DAMPER MATRIX PARA MODELO DE ACTUADOR SKU04855 4" x 4" x 2" SEÑALES EMT: 3/4" NORTH 1 ACTUADOR 3 3 SA DAMP ACTUATOR POS DET 1 3/2/2022 2:36:07 PM 4 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 2 SA DAMP ACTUATOR POS DET 2 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL DETALLES DE POSICION DE ACTUADORES CL-3059-LH-BD-MP-35 DX PAGE 35 OF 47 CO IL EVAP. DIRECT SKU04836 8" x 8" x 6" VER PAG. 44 PARA DETALLE DE CONEXION DE ACTUADORES SKU04835 6" x 6" x 4" SEÑALES EMT: 1/2" PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL SEÑALES EMT: 3/4" SKU04835 4" x 4" x 2" SEÑALES EMT: 1/2" ACTUADOR SKU04833 4.76" x 4.76" x 4" ACTUADOR SHEET NOTES KEY PLAN PARA MODELO DE ACTUADOR REFERIRSE AL DAMPER MATRIX EN EL SUBMITTAL DE CONTROL NORTH 1 1 2 DX COIL BYPASS DAMPER ACTUATOR POS. 2 DIRECT EVAP BYPASS DAMPER ACTUATOR POS. 3/2/2022 2:36:12 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 PRESSURE TIPS UBICACIONES J.I.M. J.I.M. J.I.M. PAGE 36 OF 47 CL-3059-LH-BD-MP-36 7 62" FLUJO DE AIRE 62" 62" 3 56" -USAR CAJAS NEMA 3R EN AREA DE DX COIL Y DIRECT EVAP. PARA SEÑALES (REFERIRSE A BOM DE MAQUINA) 9 -PARA MAYOR DETALLE REFERIRSE AL DIAGRAMA MECANICO. 11 5 -COLOCAR CLAMPS DE ACUERDO CON LAYOUT DE STRAPS 6 68" 1 8 62" 62" 66" 66" 2 62" 1 56" 4 -PARA REFERENCIAS ELECTRICAS, REVISAR DIAGRAMA ELECTRICO 11 -USAR TUBO FLEXIBLE EN TODAS LAS TERMINACIONES EXCEPTO EN AREA DE DX COIL Y DIRECT EVAP. USAR LIQUID TIGHT EN ZONA HUMEDA. PRESSURE TIPS LOCATIONS 1 1/4" = 1'-0" -INSTALAR GFCI Y LIGHT SWITCH POR DENTRO DE LA MAQUINA. NO HABRA OUTLETS POR FUERA. -COLOCAR CHILILLOS EN OREJAS EXTERNAS DE LAMPARAS 1 4 MA.FLTR.DP.LOW 5 FILTER GAUGE LOW DX.COIL.DP.HIGH 6 DX.COIL.DP.LOW 7 SA.LPS.LOW 8 SA.FAN.DP.LOW 9 FLUJO DE AIRE PARED SUR # TAG EA.HPS.HIGH 1 2 MA.FLTR.DP.HIGH 3 FILTER GAUGE HIGH 10 11 SHEET NOTES KEY PLAN NORTH SA.HPS.HIGH SA.FAN.DP.HIGH 1 2 3/2/2022 2:36:34 PM 3 PRESSURE TIPS DETAIL 3/4" = 1'-0" 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PRESSURE TIP ON EXHAUST FAN 1/4" = 1'-0" 4 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 2 TABLA DE TAGS DE PRESSURE TIPS 6" = 1'-0" 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt NO. DATE DESCRIPTION DWN. APP. 3 4 5 SEE REVISION SHEET SEE REVISION SHEET SEE REVISION SHEET C.M. C.M. C.M. 01/19/2021 02/07/2021 03/02/2021 J.I.M. J.I.M. J.I.M. CL-3059-LH-BD-MP-37 DETALLE DE SSPP Y CONTROL PANEL PAGE 37 OF 47 UTILIZAR UN CABLE DE 10 GAUGE PARA TIERRA DE PANEL DE CONTROL 30 EQUIPMENT GROUND 460V/3PH/60Hz L1 L2 L3 USE COOPER CONDUCTORS ONLY S/S VFD1/VFD2 FR-1/FR-3/FR-11 TB-24VAC FR-4 R1 THRU R12 FR-5 INSTALAR PUENTE ENTRE BARRAS DE TIERRA DE SSPP PDB1 XFMR-1 XFMR-2 Disc.Sw. CONTROLS FLM 10A XFMR-3 Disc.Sw. LIGHTS XFMR-1 XFMR-2 TB-120VAC XFMR-3 Tightening torque 159 lb In use 75 C min. wire O CS C SF-1 1 -SF SF-2 SF-3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 60 F2 S-S CS 3 -SF CS 30A 30A SKU09342, INSULATED RING TERMINAL, NO-10, INSULATION COLOR YELLOW 30A 4 -SF SF-4 5 -SF CS SF-5 SF-6 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 PDB2 6 -SF CS CS CS 30A 30A 30A 7 -SF 8 -SF CS 9 -SF 10 -SF CS SF-7 SF-8 SF-9 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 30A 30A 30A 11 -SF CS 12 -SF CS SF-10 SF-11 SF-12 PDB3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 GROUND GROUND 30A 30A 30A INSTALAR PUENTE ENTRE BARRAS DE TIERRA DE SSPP SHEET NOTES KEY PLAN NORTH SINGLE SOURCE POWER PANEL ENCLOSURE SIZE 30Wx60Hx12D NEMA 3R 1 SSPP 3/4" = 1'-0" 2 DETALLE DE SSPP 1/8" = 1'-0" 3 CONTROL PANEL 1/8" = 1'-0" SKU09342, INSULATED RING TERMINAL, NO-10, INSULATION COLOR YELLOW 1 2 3/2/2022 2:36:39 PM 2285 Michael Faraday Dr. Suite 15 San Diego, CA 92154 Phone (619) 428-9688 Fax (619) 428-9689 PROJECT NAME 3059 - NHA6 MODEL UNIT TAG SEE CHART FB SKU: 4SV-48-FP-EC-FF-DX-DE-PF 50-0-2-48FPECFFDXDEFP-P-L PROJECT ENGENEER: Checker DESIGN ENGENEER: C. MORALES Scale: As indicated Date: 02/07/2022 DWG UNITS: INCHES \\aphrodite\l_aap$\Project\3000\30003\2105-3059 NHA6\Submittal\Conduit Layout\NHA6 AHU MPOE BD - LH.rvt Job Name: Job Number: Unit Tag: Revision: Device SA.DMPR.ACT (A) SA.DMPR.ACT (B) SA.DMPR.ACT (C) SA.DMPR.ACT (D) EA.DMPR.ACT (A) EA.DMPR.ACT (B) NHA6 2105-3059 AHU-BD 0 AAP SKU SKU03267 SKU03267 SKU03267 SKU03267 SKU03284 SKU03284 Jacket Label SA.DMPR.ACT-PWR-HW-A 2309 ; 2359 SA.DMPR.ACT.OpenCmd 2313 SA.DMPR.ACT-HW-A 2315 ; 2315 SA.DMPR.ACT-PWR-HW-B 2310 ; 2360 SA.DMPR.ACT.OpenCmd-A 2365 SA.DMPR.ACT-HW-B 2316 ; 2366 SA.DMPR.ACT-PWR-HW-C 2311 ; 2361 SA.DMPR.ACT.OpenCmd-B 2365 SA.DMPR.ACT-HW-C 2318 ; 2368 SA.DMPR.ACT-PWR-HW-D 2312 ; 2362 SA.DMPR.ACT.OpenCmd-C 2365 SA.DMPR.ACT.PosFb 4385 SA.DMPR.ACT-HW-D 2319 ; 2369 EA.DMPR.ACT-PWR-HW-A 2321 ; 2371 EA.DMPR.ACT-HW-A 2323 ; 2323 EA.DMPR.ACT.PosSig 5221 EA.DMPR.ACT-PWR-HW-B 2372 ; 2372 EA.DMPR.ACT-HW-B 2327 ; 2377 EA.DMPR.ACT.PosSig-A 5223 EA.DMPR.ACT.PosFb 4381 Color Conductor Label Left Origin Point Termination Point Drawing # BLK WHT WHT 2309.01 1173.02.01.00 2313.00 SA.DMPR.A (2) SA.DMPR.A (1) SA.DMPR.A (3) TS9-1 TS9-2 TS9-3 4.1.123 4.1.123 4.1.123 BLK WHT BLK WHT WHT 2309.04 - SA.DMPR.A (S4) SA.DMPR.A (S6) SA.DMPR.B (2) SA.DMPR.B (1) SA.DMPR.B (3) TS9-4 TS9-5 SA.DMPR.A (2) SA.DMPR.A (1) SA.DMPR.A (5) 4.1.123 4.1.123 4.1.123 4.1.123 4.1.123 BLK WHT BLK WHT WHT - SA.DMPR.B (S4) SA.DMPR.B (S6) SA.DMPR.C (2) SA.DMPR.C (1) SA.DMPR.C (3) TS9-5B TS9-6 SA.DMPR.B (2) SA.DMPR.B (1) SA.DMPR.B (5) 4.1.123 4.1.123 4.1.123 4.1.123 4.1.123 1 BLK WHT BLK WHT WHT - SA.DMPR.C (S4) SA.DMPR.C (S6) SA.DMPR.D (2) SA.DMPR.D (1) SA.DMPR.D (3) TS9-6B TS9-7 SA.DMPR.C (2) SA.DMPR.C (1) SA.DMPR.C (5) 4.1.123 4.1.123 4.1.123 4.1.123 4.1.123 SKU05049 1 GRN 1173.01.20 SA.DMPR.D (5) DIST01-AI.07 4.1.123 W181P-2051RIB SKU05053 2 18-2 PWR W181P-2051RIB SKU05053 2 N.C. 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT BLK WHT BLK WHT WHT 2369.01 1173.02.02.00 2321.02 - SA.DMPR.D (S4) SA.DMPR.D (S6) EA.DMPR.A (2) EA.DMPR.A (1) EA.DMPR.A (S4) EA.DMPR.A (S5) EA.DMPR.A (3) TS9-7B TS9-8 TS9-10 TS9-11 TS9-12 TS9-13 DIST10-AO.02 4.1.123 4.1.123 4.1.123 4.1.123 4.1.123 4.1.123 4.1.152 Power 18-2 PWR W181P-2051RIB SKU05053 2 N.C. 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT BLK WHT WHT 2377.01 - EA.DMPR.B (2) EA.DMPR.B (1) EA.DMPR.B (S4) EA.DMPR.B (S5) EA.DMPR.B (3) EA.DMPR.A (2) EA.DMPR.A (1) TS9-15 TS9-16 EA.DMPR.A (5) 4.1.123 4.1.123 4.1.123 4.1.123 4.1.152 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.20 EA.DMPR.B (5) DIST01-AI.06 4.1.143 Signal Type Cable Type Manf. Part Number AAP SKU # Wires Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 N.O. 18-2 PWR W181P-2051RIB SKU05053 2 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 N.O. 18-2 PWR W181P-2051RIB SKU05053 2 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 N.O. 18-2 PWR W181P-2051RIB SKU05053 2 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 Feedback 18-4 S W184C-2059RIB N.O. 18-2 PWR Power Page 1 of 6 Job Name: Job Number: Unit Tag: Revision: Device OA.DMPR1.ACT OA.DMPR2.ACT (A) OA.DMPR2.ACT (B) RA.DMPR.ACT (A) RA.DMPR.ACT (B) RA.DMPR.ACT (C) DX.BPDMPR1.ACT NHA6 2105-3059 AHU-BD 0 AAP SKU SKU03255 SKU03255 SKU03255 SKU03254 SKU03254 SKU03254 SKU03284 Jacket Label OA.DMPR1.ACT-PWR 2213 ; 2263 OA.DMPR1.ACT-PWR-HTR 2227 ; 2277 OA.DMPR1.ACT.PosSig 5105 OA.DMPR1.ACT.PosFb 4357 OA.DMPR2.ACT-PWR-A 2215 ; 2265 OA.DMPR2.ACT-PWR-HTR-A 2229 ; 2279 OA.DMPR2.ACT.PosSig 5113 OA.DMPR2.ACT-PWR-B 2216 ; 2216 OA.DMPR2.ACT-PWR-HTR-B 2231 ; 2281 OA.DMPR2.ACT.PosSig-A 5115 OA.DMPR2.ACT.PosFb 4361 RA.DMPR.ACT-PWR-A 2217 ; 2267 RA.DMPR.ACT.PosSig 5121 RA.DMPR.ACT-PWR-B 2268 ; 2268 RA.DMPR.ACT.PosSig-A 5123 RA.DMPR.ACT-PWR-C 2269 ; 2269 RA.DMPR.ACT.PosSig-B 5125 RA.DMPR.ACT.PosFb 4365 DX.BPDMPR1.ACT-PWR 2219 ; 2269 DX.BPDMPR1.ACT.PosSig 5129 DX.BPDMPR1.ACT.PosFb 4369 Signal Type Cable Type Manf. Part Number AAP SKU # Wires Color Conductor Label Left Origin Point Termination Point Drawing # Power 18-2 PWR W181P-2051RIB SKU05053 2 1 BLK WHT BLK WHT WHT 1172.03 1173.03 1172.03 1173.03 - OA.DMPR1 (2) OA.DMPR1 (1) OA.DMPR1 (H2) OA.DMPR1 (H1) OA.DMPR1 (3) TS7-11 TS7-12 TS7-27 TS7-28 DIST09-AO.00 4.1.122 4.1.122 4.1.122 4.1.122 4.1.151 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.20 OA.DMPR1 (5) DIST01-AI.00 4.1.143 Power 18-2 PWR W181P-2051RIB SKU05053 2 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT BLK WHT WHT 1172.03 1173.03 1172.03 1173.03 - OA.DMPR2.A (2) OA.DMPR2.A (1) OA.DMPR2.A (H2) OA.DMPR2.A (H1) OA.DMPR2.A (3) TS7-13 TS7-14 TS7-29 TS7-30 DIST09-AO.01 4.1.122 4.1.122 4.1.122 4.1.122 4.1.151 Power Power 18-2 PWR W181P-2051RIB SKU05053 2 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT BLK WHT WHT 1172.03 1173.03 - OA.DMPR2.B (2) OA.DMPR2.B (1) OA.DMPR2.B (H2) OA.DMPR2.B (H1) OA.DMPR2.B (3) OA.DMPR2.A (2) OA.DMPR2.A (1) TS7-31 TS7-32 OA.DMPR2.A (5) 4.1.122 4.1.122 4.1.122 4.1.122 4.1.151 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.20 OA.DMPR2.B (5) DIST01-AI.01 4.1.143 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT 1172.03 1173.03 - RA.DMPR.A (2) RA.DMPR.A (1) RA.DMPR.A (3) TS7-15 TS7-16 DIST09-AO.02 4.1.122 4.1.122 4.1.151 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT - RA.DMPR.B (2) RA.DMPR.B (1) RA.DMPR.B (3) RA.DMPR.A (2) RA.DMPR.A (1) RA.DMPR.A (5) 4.1.122 4.1.122 4.1.151 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT - RA.DMPR.C (2) RA.DMPR.C (1) RA.DMPR.C (3) RA.DMPR.B (2) RA.DMPR.B (1) RA.DMPR.B (5) 4.1.122 4.1.122 4.1.151 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.20 RA.DMPR.C (5) DIST01-AI.02 4.1.143 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT 1172.03 1173.03 - DX.BPDMPR1 (2) DX.BPDMPR1 (1) DX.BPDMPR1 (3) TS7-17 TS7-18 DIST09-AO.03 4.1.122 4.1.122 4.1.151 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.20 DX.BPDMPR1 (5) DIST01-AI.03 4.1.143 Page 2 of 6 Job Name: Job Number: Unit Tag: Revision: Device DX.BPDMPR2.ACT ECH.BPDMPR.ACT ECH.VLV1.ACT ECH.VLV2.ACT ECH.VLV3.ACT ECH.VLV4.ACT NHA6 2105-3059 AHU-BD 0 AAP SKU SKU03284 SKU03267 SKU07840 SKU07840 SKU07840 SKU07839 UNIT.WD (A) SKU02102 UNIT.WD (B) SKU02102 Jacket Label DX.BPDMPR2.ACT-PWR 2221 ; 2271 DX.BPDMPR2.ACT.PosSig 5205 DX.BPDMPR2.ACT.PosFb 4373 ECH.BPDMPR.ACT-PWR 2223 ; 2273 ECH.BPDMPR.ACT.PosSig 5213 ECH.BPDMPR.ACT.PosFb 4377 ECH.VLV1.ACT-PWR 2205 ; 2255 ECH.VLV1.ACT.PosSig 5305 ECH.VLV1.ACT.PosFb 4457 ECH.VLV2.ACT-PWR 2207 ; 2257 ECH.VLV2.ACT.PosSig 5313 ECH.VLV2.ACT.PosFb 4461 ECH.VLV3.ACT-PWR 2209 ; 2259 ECH.VLV3.ACT.PosSig 5321 ECH.VLV3.ACT.PosFb 4465 ECH.VLV4.ACT-PWR 2211 ; 2261 ECH.VLV4.ACT.PosSig 5329 ECH.VLV4.ACT.PosFb 4469 UNIT.WD-PWR-A 2524 ; 2574 UNIT.WD.ALM-HW-A 2523 ; 2573 UNIT.WD-PWR-B 2527 ; 2577 UNIT.WD.ALM-HW-B 2526 ; 2576 Signal Type Cable Type Manf. Part Number AAP SKU # Wires Color Conductor Label Left Origin Point Termination Point Drawing # Power 18-2 PWR W181P-2051RIB SKU05053 2 1 BLK WHT WHT 1172.03 1173.03 - DX.BPDMPR2 (2) DX.BPDMPR2 (1) DX.BPDMPR2 (3) TS7-19 TS7-20 DIST10-AO.00 4.1.122 4.1.122 4.1.152 Command 18-4 S W184C-2059RIB SKU05049 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.20 DX.BPDMPR2 (5) DIST01-AI.04 4.1.143 Power 18-2 PWR W181P-2051RIB SKU05053 2 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT - ECH.BPDMPR (2) ECH.BPDMPR (1) ECH.BPDMPR (3) TS7-21 TS7-22 DIST10-AO.01 4.1.122 4.1.122 4.1.152 Command Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN - ECH.BPDMPR (5) DIST01-AI.05 4.1.143 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT 1172.03 1173.03 - ECH.VLV1 (2) ECH.VLV1 (1) ECH.VLV1 (3) TS7-3 TS7-4 DIST11-AO.00 4.1.122 4.1.122 4.1.153 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.21 ECH.VLV1 (5) DIST02-AI.00 4.1.144 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT 1172.03 1173.03 - ECH.VLV2 (2) ECH.VLV2 (1) ECH.VLV2 (3) TS7-5 TS7-6 DIST11-AO.01 4.1.122 4.1.122 4.1.153 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.21 ECH.VLV2 (5) DIST02-AI.01 4.1.144 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT 1172.03 1173.03 - ECH.VLV3 (2) ECH.VLV3 (1) ECH.VLV3 (3) TS7-7 TS7-8 DIST11-AO0.2 4.1.122 4.1.122 4.1.153 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.21 ECH.VLV3 (5) DIST02-AI.02 4.1.144 Power 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-4 S W184C-2059RIB SKU05049 1 BLK WHT WHT 1172.03 1173.03 - ECH.VLV4 (2) ECH.VLV4 (1) ECH.VLV4 (3) TS7-9 TS7-10 DIST11-AO.03 4.1.122 4.1.122 4.1.153 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.21 ECH.VLV4 (5) DIST02-AI.03 4.1.144 Power 18-2 PWR W181P-2051RIB SKU05053 2 N.O. 18-2 PWR W181P-2051RIB SKU05053 2 Power 18-2 PWR W181P-2051RIB SKU05053 2 N.O. 18-2 PWR W181P-2051RIB SKU05053 2 BLK WHT BLK WHT BLK WHT BLK WHT 1172.04 1173.04 2523.00 2573.01 1172.04 1173.04 2523.00 2573.01 UNIT.WD.A (V+) UNIT.WD.A (GND) UNIT.WD.A (COM1) UNIT.WD.A (NO1) UNIT.WD.B (V+) UNIT.WD.B (GND) UNIT.WD.B (COM1) UNIT.WD.B (NO1) TS11-3 TS11-4 TS9-27 TS9-30 TS11-5 TS11-6 TS9-27 TS9-30 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 Page 3 of 6 Job Name: Job Number: Unit Tag: Revision: Device NHA6 2105-3059 AHU-BD 0 AAP SKU UNIT.WD (C) SKU02102 UNIT.WD (D) (BY OTHERS) SKU02102 SA.FAN.ECM EA.FAN.VFD1 EA.FAN.VFD2 SKU00336 SKU00932 SKU00932 EA.FAN.VFD1 FR3 (1P) SKU05493 EA.FAN.VFD.SFTY.INTLKHW FR4 (2P) SKU10226 EA.FAN.VFD2 FR11 (1P) SKU05493 EA.FAN.VFD.DMPR.INTLKHW FR5 (2P) SKU10226 DX.CU SKU07693 Jacket Label UNIT.WD-PWR-C 2530 ; 2580 UNIT.WD.ALM-HW-C 2529 ; 2579 UNIT.WD-PWR-D 2533 ; 2583 UNIT.WD.ALM-HW-D 2532 ; 2582 SA.FAN.ECM.SpdSig 4952 ; 4955 SA.FAN.ECM.FltSts 5529 ; 5529 EA.FAN.VFD1.FltSts 5557 ; 5557 EA.FAN.VFD1.SpdSig 4913 ; 4914 EA.FAN.VFD1.RunSts 5555 ; 5555 EA.DMPR.ACT-PWR-HW 2321 ; 2321 EA.FAN.VFD2.FltSts 5563 ; 5563 EA.FAN.VFD2.SpdSig 4921 ; 4922 EA.FAN.VFD2.RunSts 5561 ; 5561 EA.FAN.VFD1.RunCmd 5421 ; 5421 EA.FAN.VFD1.RunCmd-A 5471 ; 5471 EA.FAN.VFD.SFTY.INTLK-HW 2509 ; 2559 EA.FAN.VFD2.RunCmd 5423 ; 5423 EA.FAN.VFD2.RunCmd-A 5473 ; 5473 EA.FAN.VFD.DMPR.INTLK-HW 2511 ; 2561 DX.CU.PWR.FltSts 5533 ; 5533 DX.CU.FltSts 5535 ; 5535 DX.CU.StgSig 5005 ; 5006 Signal Type Cable Type Manf. Part Number AAP SKU # Wires Power 18-2 PWR W181P-2051RIB SKU05053 2 N.O. 18-2 PWR W181P-2051RIB SKU05053 2 Power 18-2 PWR W181P-2051RIB SKU05053 2 N.O. 18-2 PWR W181P-2051RIB SKU05053 2 Command 18-2 SA W181P-2040WORSB SKU05076 2 N.O. 16-2 PWR W161P-2062RIB SKU09192 2 N.O. 16-2 PWR W161P-2062RIB SKU09192 2 Command 16-2 PWR W161P-2062RIB SKU09192 2 N.O. 16-2 PWR W161P-2062RIB SKU09192 2 Power 16-2 PWR W161P-2062RIB SKU09192 2 N.O. 16-2 PWR W161P-2062RIB SKU09192 2 Command 16-2 PWR W161P-2062RIB SKU09192 2 N.O. 16-2 PWR W161P-2062RIB SKU09192 2 Power 16-2 PWR W161P-2062RIB SKU09192 2 N.C. 18-2 D W181P-2051WRDRB SKU05077 2 Power 16-2 PWR W161P-2062RIB SKU09192 2 Power 16-2 PWR W161P-2062RIB SKU09192 2 N.C. 18-2 D W181P-2051WRDRB SKU05077 2 Power 16-2 PWR W161P-2062RIB SKU09192 2 N.O. 18-2 D W181P-2051WRDRB SKU05077 2 N.O. 18-2 D W181P-2051WRDRB SKU05077 2 Command 18-2 SA W181P-2040WORSB SKU05076 2 Page 4 of 6 Color Conductor Label Left Origin Point Termination Point Drawing # BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT 1172.04 1173.04 2523.00 2573.01 1172.04 1173.04 2523.00 2573.01 1173.01.22.00.01 4952A.00 2110.00 1173.01.07 2111.00 1173.01.08 1173.01.22 4905.00 2111.00 1173.01.08 2321A.00 2111.00 1173.01.08 1173.01.22 4905.00 2111.00 1173.01.08 1173.01.06 2109.00 2509A.00 1173.02.09 1173.01.06 2109.00 2511A.00 1173.02.10 2110.00 1173.01.07 2110.00 1173.01.07 1173.01.23 - UNIT.WD.C (V+) UNIT.WD.C (GND) UNIT.WD.C (COM1) UNIT.WD.C (NO1) UNIT.WD.D (V+) UNIT.WD.D (GND) UNIT.WD.D (COM1) UNIT.WD.D (NO1) SA.FAN.ECM (GND) SA.FAN.ECM (E1) CR1-1 (11) CR12-1 (14) EA.FAN.VFD1 (25) EA.FAN.VFD1 (27) EA.FAN.VFD1 (3) EA.FAN.VFD1 (2) EA.FAN.VFD1 (22) EA.FAN.VFD1 (24) EA.FAN.VFD1 (20) EA.FAN.VFD2 (19) EA.FAN.VFD2 (25) EA.FAN.VFD2 (27) EA.FAN.VFD2 (3) EA.FAN.VFD2 (2) EA.FAN.VFD2 (22) EA.FAN.VFD2 (24) EA.VFD1.FR3 (A2) EA.VFD1.FR3 (A1) EA.VFD1.FR3 (11) EA.VFD1.FR3 (12) EA.SFTY.INTLK (A1) EA.SFTY.INTLK (A2) EA.VFD2.FR11 (A2) EA.VFD2.FR11 (A1) EA.VFD2.FR11 (11) EA.VFD2.FR11 (12) EA.DMPR.INTLK (A1) EA.DMPR.INTLK (A2) DX.CU (-XF 6) DX.CU (-XF 7) DX.CU (-XF 4) DX.CU (-XF 5) DX.CU (-XF 10) DX.CU (-XF 9) TS11-7 TS11-8 TS9-28 TS9-31 TS11-9 TS11-10 TS9-28 TS9-31 TS13-4 TS13-3 DIST13-24.12 DIST13-DI.12 DIST13-24.17 DIST13-DI.17 DIST07-1 DIST07-AO.01 DIST13-24.16 DIST13-DI.16 TS9-9 TS9-10 DIST13-24.20 DIST13-DI.20 DIST07-2 DIST07-AO.02 DIST13-24.19 DIST13-DI.19 DIST12-8 DIST12-DO.08 TB-70 EA.FAN.VFD1 (13) TS9-23 TS9-24 DIST12-9 DIST12-DO.09 TB-72 EA.FAN.VFD2 (13) TS9-25 TS9-26 DIST13-24.14 DIST13-DI.14 DIST13-24.15 DIST13-DI.15 DIST08-0 DIST08-AO.00 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 4.1.125 4.1.149 4.1.149 4.1.155 4.1.155 4.1.155 4.1.155 4.1.149 4.1.149 4.1.155 4.1.155 4.1.171 4.1.171 4.1.155 4.1.155 4.1.149 4.1.149 4.1.155 4.1.155 4.1.154 4.1.154 4.1.154 4.1.154 4.1.125 4.1.125 4.1.154 4.1.154 4.1.154 4.1.154 4.1.125 4.1.125 4.1.155 4.1.155 4.1.155 4.1.155 4.1.150 4.1.150 Job Name: Job Number: Unit Tag: Revision: Device DX.CU FR1 (1P) MA.[HUM/WBT] SA.FAN.ECM.SFTY.INTLK SFSI (3P) SA.SMK.INTLK-HW (BY OTHERS) NHA6 2105-3059 AHU-BD 0 AAP SKU SKU05493 SKU04045 SKU05515 - SA.HUM SKU04046 RA.HUM SKU04046 MA.TEMP SKU05135 SA.TEMP SKU05134 RA.TEMP SKU05134 DX.COIL.TEMP SKU05136 Jacket Label DX.CU.EnblCmd 5429 ; 5429 DX.CU.EnblCmd-A 5479 ; 5479 MA.[HUM/WBT]-PWR 2203 ; 2253 MA.HUM.Fb 4582 MA.WBT.Fb 4586 SA.FAN.ECM.SFTY.INTLK 2505 ; 2555 SA.SMK.INTLK-HW 2507 ; 2557 SA.HUM.Fb 4573 ; 4574 RA.HUM.Fb 4577 ; 4578 MA.TEMP.Fb 4657 ; 4658 SA.TEMP.Fb 4661 ; 4662 RA.TEMP.Fb 4665 ; 4666 DX.COIL.TEMP.Fb 4669 ; 4670 Signal Type Cable Type Manf. Part Number AAP SKU # Wires Color Conductor Label Left Origin Point Termination Point Drawing # Power 16-2 PWR W161P-2062RIB SKU09192 2 1 BLK WHT BLK WHT BLK WHT WHT 1173.01.06 2109.00 1172.03 1173.03 1173.01.02 DX.CU.FR1 (A2) DX.CU.FR1 (A1) DX.CU.FR1 (11) DX.CU.FR1 (14) MA.[HUM/WBT] (+) MA.[HUM/WBT] (-) MA.[HUM/WBT] (CH2+) DIST12-12 DIST12-DO.12 DX.CU (-XF 11) DX.CU (-XF 12) TS7-1 TS7-2 DIST03-AI.06 4.1.154 4.1.154 4.1.154 4.1.154 4.1.122 4.1.122 4.1.145 N.O. 18-2 D W181P-2051WRDRB SKU05077 2 Power 18-2 PWR W181P-2051RIB SKU05053 2 Feedback 18-4 S W184C-2059RIB SKU05049 Feedback 18-4 S W184C-2059RIB SKU05049 1 GRN 1173.01.02 MA.[HUM/WBT] (CH1+) DIST03-AI.07 4.1.145 Power 16-2 PWR W161P-2062RIB SKU09192 2 18-2 PWR W181P-2051RIB SKU05053 2 Feedback 18-2 SA W181P-2040WORSB SKU05076 2 Feedback 18-2 SA W181P-2040WORSB SKU05076 2 Feedback 18-2 SA W181P-2040WORSB SKU05076 2 Feedback 18-2 SA W181P-2040WORSB SKU05076 2 Feedback 18-2 SA W181P-2040WORSB SKU05076 2 Feedback 18-2 SA W181P-2040WORSB SKU05076 2 BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT BLK WHT 2503D.02 1173.02.07.01 2507.00 2557.01 2105.00 1173.01.02 2105.00 1173.01.02 2106.00 1173.01.03 2106.00 1173.01.03 2106.00 1173.01.03 2106.00 1173.01.03 SA.FAN.INTLK (A2) SA.FAN.INTLK (A1) SA.HUM (+RH) SA.HUM (-RH) RA.HUM (+RH) RA.HUM (-RH) MA.TEMP (+) MA.TEMP (-) SA.TEMP (+) SA.TEMP (-) RA.TEMP (+) RA.TEMP (-) DX.COIL.TEMP (+) DX.COIL.TEMP (-) TS9-19 TS9-20 TS9-21 TS9-22 DIST03-24.04 DIST03-AI.04 DIST03-24.05 DIST03-AI.05 DIST04-24.00 DIST04-AI.00 DIST04-24.01 DIST04-AI.01 DIST04-24.02 DIST04-AI.02 DIST04-24.03 DIST04-AI.03 4.1.125 4.1.125 4.1.125 4.1.125 4.1.145 4.1.145 4.1.145 4.1.145 4.1.146 4.1.146 4.1.146 4.1.146 4.1.146 4.1.146 4.1.146 4.1.146 N.C. Page 5 of 6 Job Name: Job Number: Unit Tag: Revision: NHA6 2105-3059 AHU-BD Device 0 AAP SKU Jacket Label Signal Type SA.LPS.HI SA.LPS SA.LPS.LO SA.HPS.HI SA.HPS SA.HPS.LO EA.HPS.HI EA.HPS EA.HPS.LO MA.FLTR.DP.HI MA.FLTR.DP MA.FLTR.DP.LO DX.COIL.DP.HI DX.COIL.DP DX.COIL.DP.LO SA.FAN.DP.HI SA.FAN.DP SA.FAN.DP.LO Jacket Label Origin Jacket Label Termination FROM: AHU ICPNL, ERIO-0, SLOT 2, PORT 0, RJ45-1 TO: EF VFD01 FROM: EF VFD01 TO: AHU ICPNL, ERIO-0, SLOT 2, PORT 0, RJ45-1 FROM: EF VFD01 TO: EF VFD02 FROM: EF VFD02 TO: EF VFD01 FROM: EF VFD02 TO: AHU ICPNL, ERIO-0, SLOT 2, PORT 0, TS13 FROM: AHU ICPNL, ERIO-0, SLOT 2, PORT 0, TS13 TO: EF VFD02 FROM: AHU ICPNL, ERIO-0, SLOT 2, PORT 0, TS13 TO: ECM SF01 FROM: ECM SF01 TO: AHU ICPNL, ERIO-0, SLOT 2, PORT 0, TS13 FROM: ECM SF01 TO: ECM SF02 FROM: ECM SF02 TO: ECM SF01 FROM: ECM SF02 TO: ECM SF03…12 FROM: ECM SF03…12 ECM SF02 Signal Type TO: Modbus (+) Modbus (-) Modbus (GND) Modbus (+) Modbus (-) Modbus (GND) Modbus (+) Modbus (-) Modbus (GND) Modbus (+) Modbus (-) Modbus (GND) Modbus (+) Modbus (-) Modbus (GND) Modbus (+) Modbus (-) Modbus (GND) Cable Type Manf. Part Number AAP SKU # Wires Color POLYTUBING 1219-440F3 SKU04067 1 BLK W/BLUE POLYTUBING 1219-440B3 SKU04068 1 BLK W/RED POLYTUBING 1219-440F3 SKU04067 1 BLK W/BLUE POLYTUBING 1219-440B3 SKU04068 1 BLK W/RED POLYTUBING 1219-440F3 SKU04067 1 BLK W/BLUE POLYTUBING 1219-440B3 SKU04068 1 BLK W/RED POLYTUBING 1219-440F3 SKU04067 1 BLK W/BLUE POLYTUBING 1219-440B3 SKU04068 1 BLK W/RED POLYTUBING 1219-440F3 SKU04067 1 BLK W/BLUE POLYTUBING 1219-440B3 SKU04068 1 BLK W/RED POLYTUBING 1219-440F3 SKU04067 1 BLK W/BLUE POLYTUBING 1219-440B3 SKU04068 1 BLK W/RED Cable Type Manf. Part Number APP SKU # Wires Color RS-485 W223C-2561ORRB SKU05079 3 RS-485 W223C-2561ORRB SKU05079 3 RS-485 W223C-2561ORRB SKU05079 3 RS-485 W223C-2561ORRB SKU05079 3 RS-485 W223C-2561ORRB SKU05079 3 RS-485 W223C-2561ORRB SKU05079 3 Page 6 of 6 BLK WHT RED BLK WHT RED BLK WHT RED BLK WHT RED BLK WHT RED BLK WHT RED Conductor Label Left Origin Point Termination Point Drawing # Conductor Label Left Origin Point Termination Point Drawing # RJ45-1 (4) RJ45-1 (5) RJ45-1 (8) EF.FAN.VFD1 (29) EF.FAN.VFD1 (30) EF.FAN.VFD1 (31) EF.FAN.VFD2 (29) EF.FAN.VFD2 (30) EF.FAN.VFD2 (31) TS13 (5) TS13 (6) TS13 (7) SA.FAN.ECM1 (A) SA.FAN.ECM1 (B) SA.FAN.ECM1 (GND) SA.FAN.ECM2 (A) SA.FAN.ECM2 (B) SA.FAN.ECM2 (GND) EF.FAN.VFD1 (29) EF.FAN.VFD1 (30) EF.FAN.VFD1 (31) EF.FAN.VFD2 (29) EF.FAN.VFD2 (30) EF.FAN.VFD2 (31) TS13 (5) TS13 (6) TS13 (7) SA.FAN.ECM1 (A) SA.FAN.ECM1 (B) SA.FAN.ECM1 (GND) SA.FAN.ECM2 (A) SA.FAN.ECM2 (B) SA.FAN.ECM2 (GND) SA.FAN.ECM12 (A) SA.FAN.ECM12 (B) SA.FAN.ECM12 (GND) 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142 4.1.142