Hoja de datos de rendimiento THG1352YKS General Modelo THG1352YKS Unidad de medida Celsius Condición ASHRAE() Tensión / Frecuencia 220V ~ 50HZ Tipo de motor PTCCS_IR GAS DE VUELTA Información de rendimiento Temperatura de condensación (°C) EVAP TEMP (°C) 30 35 40 45 50 55 60 Btu / h Watts (Power) -40 Amperios Lb / h Btu / h Watts (Power) -35 Amperios Lb / h Btu / h Watts (Power) -30 Amperios Lb / h Btu / h Watts (Power) -25 Amperios Lb / h Btu / h Watts (Power) -23.3 Amperios Lb / h Btu / h Watts (Power) -20 Amperios Lb / h Btu / h Watts (Power) -15 Amperios Lb / h Btu / h Watts (Power) -10 Amperios Lb / h COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW C1 1,800000E+05 5,410000E+02 1,030000E+02 2,220000E+03 C2 4,850000E+03 -4,450000E+02 -1,260000E+00 5,960000E+01 65 C3 -1,160000E+03 3,430000E+02 -1,880000E+00 -1,430000E+01 C4 5,560000E+01 -9,870000E+00 -3,150000E-02 6,830000E-01 C5 3,620000E+01 1,720000E+01 8,250000E-02 4,430000E-01 C6 2,460000E+01 -9,120000E-01 7,240000E-02 3,020000E-01 C7 1,240000E-01 -7,600000E-02 -1,920000E-04 1,530000E-03 C8 1,170000E-01 1,290000E-01 6,920000E-04 1,440000E-03 C9 -3,930000E-01 -7,600000E-02 -2,560000E-04 -4,800000E-03 C10 -2,640000E-01 -1,170000E-02 -5,720000E-04 -3,240000E-03 Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3 Te = Temperatura del evaporador Tc = Temperatura de condensación