® SECTION 62.61 2009-09 TECHNOLOGIES INDUSTRIAL ENERGY Page 1 ® A WORLD LEADER IN VALVE REGULATED LEAD ACID (VRLA) BATTERY POWER FOR PHOTOVOLTAIC AND ALTERNATIVE ENERGY APPLICATIONS • Proven Field Experience Since 1983. • The Absolyte was developed by GNB, now known as Exide Technologies Industrial Energy, in conjunction with Sandia National Laboratories, as the first VRLA, large capacity, deep-cycle battery for photovoltaic applications. • Patented lead-calcium-tin-sliver positive grid alloy provides excellent cycle life for photovoltaic applications. • Provides for extended partial state of charge operation and allows for deep discharge recovery. • Wide band of temperature operation — retains more capacity in cold temperatures than traditional flooded batteries. • Modular steel tray design provides excellent heat dissipation in high temperature applications. APPLICATIONS Absolyte GP batteries are ideal for photovoltaic and alternative energy applications including: • Village Electrification • Telecommunications • Residential Power • Railroad Signal • Navigational Aids ADDED FEATURES AND BENEFITS • Extended partial state of charge operation • Deep discharge recovery • Freezing tolerant • Does not require separate battery room • Recombination efficiency greater than 99% • Globally recyclable design • Single cell and stackable modules are available • Simple cell replacement capability • Housed in protective steel trays designed for maximum installation flexibility. • Single cell modules are available that simplify transport to remote locations. • Eliminates the need for periodic water additions as found in flooded cells. Periodic visual inspections, voltage readings, and connection retorquing is all that is required. • Enhanced Post Access for maintenance and battery health assessment. • Absolyte GP is qualified to stack horizontally up to eight high for use in 1997 UBC/2001 CBC Seismic Zone IV (at or below grade). • UL Recognized, ISO 9001:2000, NEBS Level 3 Certified in Certain Cnfigurations. ASSEMBLY CONFIGURATIONS Horizontal Stack Assembly Depth is overall, including module cover assembly. Add 102mm (4”) for bottom I-beam supports to determine total height of assembled horizontal stack. Page 2 ® Absolyte GP Stackable Module Weights and Dimensions MODULE TYPE NOM VOLTS AH CAP STACKING DIMENSIONS IN MM IN MM IN MM UNPACKED WEIGHT LBS KG LENGTH HEIGHT DEPTH (100 HR) DOMESTIC PACKED WEIGHT EXPORT PACKED WEIGHT LBS KG LBS KG 50G 6-50G05 12 140 17.19 437 8.53 217 16.22 412 157 71 176 80 228 104 6-50G07 12 210 21.69 551 8.53 217 16.22 412 209 95 228 104 280 127 6-50G09 12 290 26.19 665 8.53 217 16.22 412 252 114 271 123 323 147 6-50G13 12 430 35.19 894 8.53 217 16.22 412 356 162 381 173 433 197 6-90G07 12 360 21.69 551 8.53 217 23.56 599 316 143 335 152 413 187 6-90G09 12 480 26.19 665 8.53 217 23.56 599 396 180 415 188 493 224 6-90G11 12 600 30.69 780 8.53 217 23.56 599 477 216 502 228 581 264 6-90G13 12 720 35.19 894 8.53 217 23.56 599 557 253 582 264 661 300 6-90G15 12 840 39.69 1008 8.59 218 23.56 599 637 289 668 303 747 339 100 3-100G13 6 790 19.93 506 8.53 217 26.38 670 328 149 356 162 436 198 3-100G15 6 920 22.18 563 8.59 218 26.38 670 374 170 408 185 489 222 3-100G17 6 1000 24.50 622 8.59 218 26.38 670 424 192 446 202 528 240 3-100G19 6 1100 26.75 679 8.59 218 26.38 670 470 213 491 223 574 260 3-100G21 6 1300 29.00 737 8.59 218 26.38 670 515 234 539 245 623 283 3-100G23 6 1400 31.25 794 8.59 218 26.38 670 561 255 589 267 674 306 3-100G25 6 1500 33.50 851 8.59 218 26.38 670 608 276 637 289 723 328 3-100G27 6 1700 35.75 908 8.59 218 26.38 670 653 296 684 310 772 350 3-100G29 6 1800 38.00 965 8.59 218 26.38 670 704 319 736 334 824 374 3-100G31 6 1900 40.25 1022 8.59 218 26.38 670 750 340 783 355 873 396 3-100G33 6 2100 42.50 1080 8.59 218 26.38 670 795 361 829 376 920 417 1-100G39 2 2370 19.93 506 8.53 217 26.38 670 328 149 356 162 436 198 1-100G45 2 2760 22.18 563 8.59 218 26.38 670 374 170 408 185 489 222 1-100G51 2 3000 24.50 622 8.59 218 26.38 670 424 192 446 202 528 240 1-100G57 2 3300 26.75 679 8.59 218 26.38 670 470 213 491 223 574 260 1-100G63 2 3900 29.00 737 8.59 218 26.38 670 515 234 539 245 623 283 1-100G69 2 4200 31.25 794 8.59 218 26.38 670 561 255 589 267 674 306 1-100G75 2 4500 33.50 851 8.59 218 26.38 670 608 276 637 289 723 328 1-100G81 2 5100 35.75 908 8.59 218 26.38 670 653 296 684 310 772 350 1-100G87 1-100G93 2 2 5400 38.00 5700 40.25 965 1022 8.59 8.59 218 218 26.38 26.38 670 670 704 750 319 340 736 783 334 355 824 873 374 396 1-100G99 2 6300 42.50 1080 8.59 218 26.38 670 795 361 829 376 920 417 90G * Includes 77 mm (3") additional for Module Cover Assembly. For V-0 models, add a V suffix (example 3-100G33V). NOTE: Design and/or specifications are subject to change without notice. If questions arise, contact your local Exide Network Power sales representative for clafification. Page 3 ® Operating Temperature — Temperature excursions between -40°C (-40°F) to +50°C (122°F) allowed (battery performance and life will be affected). CELL SPECIFICATIONS 140-6300 AH @ 100 Hour Rate Container and Cover — Polypropylene. Cycle Life — 1200 cycles at 80% D.O.D. [at 25˚C (77˚F)] when operated per the I&O Manual. Flame retardant UL94 V-0/28% L.O.I. is optional. Separators — Spun glass, microporous matrix. Safety Vent — 3-10 psi opening pressure, self-resealing. Terminals — Solid copper insert. Positive Plate — Patented Lead-Calcium-Tin-Silver grid alloy. Negative Plate — Lead-Calcium grid alloy. Self Discharge — 0.5 to 1.0% per week maximum at 25˚C (77˚F). Charge Controller Upper Voltage Settings— at 25°C (77°F) with a maximum charge current of 5% of nominal C/100 Amp-hour rating. 2.28 ± 0.02 V.P.C. @ 0-2% D.O.D. 2.33 ± 0.02 V.P.C. @ 3-5% D.O.D. 2.38 ± 0.02 V.P.C. @ >5% D.O.D. For other temperatures and charge currents, contact Exide Technologies for recommendations. Absolyte GP Single Cell Module Weights and Dimensions CELL TYPE 50G 50G05 50G07 50G11 50G13 50G15 50G19 50G27 UNPACKED WEIGHT NOM AH CAP (100 HR) IN MM IN MM IN MM LB 140 210 370 430 510 660 950 3.80 3.80 4.55 5.30 6.05 7.67 10.67 97 97 116 135 154 195 271 6.49 6.49 6.49 6.49 6.55 6.67 6.67 165 165 165 165 166 169 169 16.00 16.00 16.00 16.00 16.00 16.00 16.00 406 406 406 406 406 406 406 32 39 50 58 66 91 124 LENGTH WIDTH DEPTH OR HEIGHT NOTE: Design and/or specifications subject to change without notice. If questions arise, contact your local Exide sales representative for clarification. KG 15 18 23 26 30 41 56 DOMESTIC PACKED EXPORT PACKED WEIGHT WEIGHT LB 35 41 53 61 69 95 130 KG 16 19 24 28 31 43 59 LB KG 44 51 61 69 77 112 147 20 23 28 31 35 51 67 Page 4 ® Absolyte GP Performance Characteristics — Constant Current Amperes to 1.75 Volts Per Cell @ 25°C (77°F) HOURS CELL TYPE 50G 120 100 72 48 36 24 20 12 10 8 50G05 50G07 1.2 1.8 1.4 2.1 1.9 2.9 2.8 4.2 3.6 5.5 5.1 7.7 6 9.1 9.3 14 11 16 13 19 50G09 50G11 50G13 50G15 50G19 50G27 2.4 3.1 3.7 4.3 5.6 8.0 2.9 3.7 4.3 5.1 6.6 9.5 3.9 5.0 5.9 6.9 8.9 13 5.6 7.1 8.5 10 13 19 7.3 9.2 11 13 17 24 10 13 15 18 23 34 12 15 18 21 27 39 18 23 28 33 42 61 22 27 33 38 49 71 26 33 39 46 59 85 90G 90G07 90G09 90G11 90G13 3.0 4.0 5.0 6.1 3.6 4.8 6.0 7.2 4.9 6.5 8.1 9.8 7.0 9.4 11 14 9.1 12 15 18 12 17 21 25 15 20 25 30 23 31 39 47 27 36 46 55 32 43 54 65 90G15 100G 7.1 8.4 11 16 21 30 35 55 64 76 100G13 100G15 100G17 100G19 100G21 100G23 100G25 100G27 100G29 100G31 100G33 100G39 100G45 100G51 100G57 100G63 100G69 100G75 100G81 100G87 100G93 100G99 6.7 7.8 8.9 10 11 12 13 14 15 16 17 20 23 26 30 33 36 39 42 45 48 51 7.9 9.2 10 11 13 14 15 17 18 19 21 23 27 30 33 39 42 45 51 54 57 63 10 12 14 16 17 19 21 23 25 26 28 30 36 42 48 51 57 63 69 75 78 84 15 18 20 23 25 28 31 33 36 38 41 45 54 60 69 75 84 93 99 108 114 123 20 23 26 30 33 36 40 43 46 50 53 60 69 78 90 99 108 120 129 138 150 159 29 33 38 43 48 53 58 62 67 72 77 87 99 114 129 144 159 174 186 201 216 231 34 40 45 51 57 63 68 74 80 85 91 102 120 135 153 171 189 204 222 240 255 273 54 63 72 81 90 99 108 117 127 136 145 162 189 216 243 270 297 324 351 381 408 435 62 73 83 94 104 115 125 135 146 156 167 186 219 249 282 312 345 375 405 438 468 501 75 87 100 112 125 137 150 162 175 187 200 225 261 300 336 375 411 450 486 525 561 600 For additional ratings, refer to section 26.10B. Page 5 ® Absolyte GP Performance Characteristics — Constant Current Amperes to 1.80 Volts Per Cell @ 25°C (77°F) HOURS CELL TYPE 50G 120 100 72 48 36 24 20 12 10 8 50G05 50G07 50G09 50G11 50G13 50G15 50G19 1.2 1.8 2.4 3.1 3.6 4.3 5.5 1.4 2.1 2.8 3.6 4.3 5.1 6.5 1.9 2.9 3.9 4.9 5.8 6.8 8.8 2.8 4.2 5.6 7.0 8.4 10 13 3.6 5.4 7.2 9.1 10 13 16 5.1 7.7 10 13 15 18 23 6.0 9.0 12 15 18 21 27 9.2 13 18 23 27 32 42 10 16 21 26 32 37 48 12 19 25 31 38 44 57 50G27 8.0 9.4 13 18 24 34 39 60 69 82 90G07 90G09 90G11 90G13 90G15 100G 3.0 4.0 5.0 6.0 7.0 3.5 4.7 5.9 7.1 8.3 4.8 6.4 8.0 9.7 11 6.9 9.3 11 13 16 9.0 12 15 18 21 12 17 21 25 29 14 19 24 29 34 23 31 39 46 54 27 36 45 54 63 32 43 53 64 75 100G13 100G15 100G17 100G19 100G21 100G23 100G25 100G27 100G29 100G31 100G33 100G39 100G45 100G51 100G57 100G63 100G69 100G75 100G81 100G87 100G93 100G99 6 7 8 9 11 12 13 14 15 16 17 19 23 26 29 33 36 39 42 45 48 51 7 9 10 11 13 14 15 17 18 19 20 23 27 30 33 39 42 45 51 54 57 60 10 12 14 15 17 19 21 22 24 26 28 30 36 42 45 51 57 63 66 72 78 84 15 17 20 22 25 28 30 33 35 38 40 45 51 60 66 75 84 90 99 105 114 120 19 23 26 29 32 36 39 42 46 49 52 57 69 78 87 96 108 117 126 138 147 156 28 33 38 42 47 52 57 61 66 71 76 84 99 114 126 141 156 171 183 198 213 228 33 39 45 50 56 62 67 73 78 84 90 99 117 135 150 168 186 201 219 234 252 270 53 62 71 80 89 98 107 116 125 134 143 159 186 213 240 267 294 321 348 375 402 429 62 72 82 93 103 113 124 134 144 155 165 186 216 246 279 309 339 372 402 432 465 495 73 85 97 110 122 134 146 159 171 183 195 219 255 291 330 366 402 438 477 513 549 585 90G For additional ratings, refer to section 26.10B. Page 6 ® Absolyte GP Performance Characteristics — Constant Current Amperes to 1.90 Volts Per Cell @ 25°C (77°F) HOURS CELL TYPE 50G 120 100 72 48 36 24 20 12 10 8 50G05 50G07 50G09 50G11 50G13 50G15 50G19 50G27 1.1 1.6 2.2 2.8 3.3 3.9 5.0 7.3 1.3 1.9 2.6 3.3 3.9 4.6 5.9 8.5 1.7 2.6 3.4 4.4 5.2 6.1 7.8 11 2.4 3.7 4.9 6.2 7.4 9 11 16 3.1 4.8 6.3 8.0 9.6 11 14 21 4.5 6.8 9.1 11 13 16 21 30 5.3 8.0 10 13 16 19 24 35 8.3 12 16 21 25 29 38 55 9 14 18 23 28 33 42 61 11 16 22 28 33 39 50 73 90G 90G07 90G09 90G11 90G13 90G15 100G 2.8 3.7 4.6 5.6 6.5 3.2 4.3 5.4 6.5 7.6 4.3 5.8 7.3 8.7 10 6.2 8.3 10 12 14 8.0 10 13 16 18 11 15 19 23 27 13 18 22 27 31 21 28 35 42 49 24 32 40 48 56 28 38 47 57 67 100G13 100G15 100G17 100G19 100G21 100G23 100G25 100G27 100G29 100G31 100G33 100G39 100G45 100G51 100G57 100G63 100G69 100G75 100G81 100G87 100G93 100G99 5.9 6.9 7.9 8.9 9.9 10 11 12 13 14 15 17 20 23 26 29 30 33 36 39 42 45 7.0 8.1 9.3 10 11 12 14 15 16 17 18 21 24 27 30 33 36 42 45 48 51 54 9.4 11 12 14 15 17 18 20 22 23 25 28 33 36 42 45 51 54 60 66 69 75 13 15 18 20 22 24 27 29 31 34 36 39 45 54 60 66 72 81 87 93 102 108 17 20 23 26 29 32 35 38 41 44 47 51 60 69 78 87 96 105 114 123 132 141 25 29 33 38 42 46 50 55 59 63 67 75 87 99 114 126 138 150 165 177 189 201 30 35 40 45 50 55 60 65 70 75 80 90 105 120 135 150 165 180 195 210 225 240 47 55 63 71 79 87 95 103 110 118 126 141 165 189 213 237 261 285 309 330 354 378 54 63 72 81 90 99 108 117 126 135 144 162 189 216 243 270 297 324 351 378 405 432 63 74 85 95 106 117 127 138 149 159 170 189 222 255 285 318 351 381 414 447 477 510 For additional ratings, refer to section 26.10B. Page 7 ® Absolyte GP Performance Characteristics Open Circuit Voltage vs. State of Charge [at 25°C (77°F)] Capacity Retention vs. Temperature -40 (-40) -30 (-22) -20 (-4) -10 (14) 0 (32) 10 (50) 20 (68) 30 (86) 40 (104) 50 (122) Page 8 ® Absolyte GP Performance Curves @ 25°C (77°F) 50G Series 1 to 10 Hours 6 5.5 5 4.5 4 3.5 3 Amp-Hours/Positive 10 9 8 7 Amps/Positive 12 to 100 Hours Amp-Hours/Positive 50G Series Amps/Positive 2.5 2 Page 9 ® Absolyte GP Performance Curves @ 25°C (77°F) 90G Series 1 to 10 Hours 6 5.5 5 4.5 4 3.5 3 Amp-Hours/Positive 10 9 8 7 Amps/Positive 12 to 100 Hours Amp-Hours/Positive 90G Series Amps/Positive 2.5 2 Page 10 ® Absolyte GP Performance Curves @ 25°C (77°F) 100G Series 1 to 10 Hours 6 5.5 5 4.5 4 3.5 3 Amp-Hours/Positive 10 9 8 7 Amps/Positive Amp-Hours/Positive 100G Series 12 to 100 Hours Amps/Positive 2.5 2 ® Exide Technologies – The Industry Leader. Exide Technologies Industrial Energy is a global leader in motive power battery and charger systems for electric lift trucks and other material handling equipment. Network power applications include communication/data networks, UPS systems for computers and control systems, electrical power generation and distribution systems, as well as a wide range of other industrial standby power applications. With a strong manufacturing base in both North America and Europe and a truly global reach (operations in more than 80 countries) in sales and service, Exide Technologies Industrial Energy is best positioned to satisfy your back up power needs locally as well as all over the world. Based on over 100 years of technological innovation the Network Power Division leads the industry with the most recognized global brands such as ABSOLYTE ®, GNB FLOODED CLASSIC™, MARATHON®, ONYX™, RELAY GEL®, SONNENSCHEIN®, and SPRINTER®. They have come to symbolize quality, reliability, performance and excellence in all the markets served. Exide Technologies takes pride in its commitment to a better environment. Its Total Battery Management program, an integrated approach to manufacturing, distributing and recycling of lead acid batteries, has been developed to ensure a safe and responsible life cycle for all of its products. Exide Technologies Industrial Energy USA – Tel: 888.898.4462 Canada – Tel: 800.268.2698 www.exide.com SECTION 62.61 2009-09 EXIDE CARES This document is printed on paper containing 10% post consumer recycled paper TECHNOLOGIES INDUSTRIAL ENERGY