SEL - NOR - CIV - 010

Anuncio
C
Ø 3/8" @.20
ESPECIFICACIONES TECNICAS
N. +0.30
N. +0.30
N. +0.30
N.P.T. +0.15
N.P.T. +0.15
N.T.N. +0.00 (N.766)
N.T.N. +0.00 (N. 766)
CUADRO DE COLUMNAS
N.P.T. +0.15
Ø 3/8" @.20
N.T.N. +0.00 (N.766)
C-1
VC-1 (25X40)
C1
VC-1 (25X40)
C1
D
C
Z-1
7
D
A
C1
D
C
Z-1
C1
VC-1 (25X40)
6
VC- 2 (25X35)
VC- 2 (25X35)
E
C
C1
VC- 2 (25X35)
2 Ø3/8"
2 Ø3/8"
3 Ø1/2"
3 Ø1/2"
D
7
N.F.Z. -1.10
N.F.Z. -1.10
A-A
B
ESC.: 1:15
VC- 1 (25X40)
VC- 2 (25X35)
C-C
ESC.: 1:15
6
4 Ø 3/8"
2 Ø 5/8"
CEMENTO PORTLAND TIPO I: EN GENERAL
CEMENTO PORTLAND TIPO MS:
4 Ø5/8"+ 4Ø1/2"
Ø 3/8":[email protected], [email protected],
[email protected], rto @.20 c/ext
Ø 3/8":[email protected], [email protected],
[email protected], rto @.20 c/ext
Ø 1/4":[email protected], 5@ 0.10
rto @.20 c/ext
PARA ESTRUCTURAS EN CONTACTO CON EL TERRENO
RECUBRIMIENTOS
COLUMNETAS
H
VC-1 (25X40)
SECCION
3 Ø1/2"
N.F.C. -0.70
"TODAS LAS UNIDADES QUE CONFORMAN LA TABIQUERIA,
DEBERAN USAR LADRILLO MAQUINADO KING KONG "
CARGAS
E-020
2 Ø 3/8"
DISEÑO SISMO RESISTENTE
DISEÑO DE CONCREO ARMADO
SUELOS Y CIMENTACIONES
E-030
E-060
E-050
ALBAÑILERIA
E-070
Ø 3/8":[email protected], [email protected],
[email protected], rto @.25 c/ext
PARAMETROS DE DISEÑO SISMORESISTENTE
3 Ø 1/2"
FACTOR DE ZONA
Z=0.25
2 Ø 3/8"
FACTOR DE USO
U=1.30
3 Ø 1/2"
2 Ø 3/8"
D-D
E-E
F-F
ESC.: 1:15
ESC.: 1:15
ESC.: 1:15
4
C1
VC-1 (25x40)
C
C1
D
B
Z-1
C1
VC-1 (25X40)
3
3 Ø 1/2"
3/8", [email protected], 6@ 0.10,
[email protected] rto @.25 c/ext
D
D
E
VC- 2 (25X35)
VC- 2 (25X35)
C1
40
L
LOS EMPALMES L
SE UBICARAN EN EL
TERCIO CENTRAL
NO SE EMPALMARAN MAS
DEL 50% DE LA
ARMADURA EN UNA
MISMA SECCION
50
50
5/8"
60
60
PROYECTO:
Ø
3/4"
70
75
1"
120
90
www.cym.pe
L
L
Rmax
1/4"
10 cm
1.5 cm
3/8"
15 cm
2.0 cm
PLANTA INDUSTRIAL
DE CAFE
UBICACIÓN:
SECTOR LA MOCHENTE,
DISTRITO DE JAEN ,
PROVINCIA JAEN
DETALLE DEL REFUERZO EN EL
NUDO VIGA COLUMNA
3 Ø 1/2"
S/E
PROPIETARIO:
2 Ø 3/8"
VC-1 (25X40)
B
DETALLE DE LA UBICACION Y LONGITUD
DE EMPALMES TRASLAPADOS PARA COLUMNAS
3 Ø 1/2"
S/E
LONGITUD DE EMPALME
Ø ACERO
E1
E2
Pulg.
cm.
cm.
G-G
3/8"
40.00
40.00
ESC.: 1:15
1/2"
50.00
40.00
5/8"
3/4"
60.00
75.00
50.00
50.00
N.F.Z. -1.10
Z-1
C1
2
H-H
ESC.: 1:15
E
N.F.P. +0.10
Z-1
VC-1 (25X40)
SELVA NORTE SAC
3 Ø 1/2"
B
C
Z-1
JOSE ALEJANDRO
DÁVILA CUEVA
CIP:182298
ESPECIALIDAD:
CIVIL
1
C1
PROF. RESPONSABLE:
PLANO:
C
L/6
ESTRUCTURAS
CUADRO DE ZAPATAS
CIMENTACION DETALLES
2
E2
SECCION
B
C
B
L
Z-1
1.00
1.00
FECHA
L
E1
2L/3
Ø 1/2" ,0.20 ambos sentidos
L/6
ENTREGA
03/30/20
N.F.Z. -1.10
CIMENTACION
Esc. : 1:50
CAD N° :
SEL - NOR - CIV - 010
.40
A
ADICIONALES
REFUERZO
ZAPATA
ÁREA DE SERVICIOS
.25
EMITIDO PARA CONSTRUCCIÓN
.25
.05 .075
1
A
40
1/2"
Ø3/8" @ 0.10 m
2 Ø 3/8"
B
A
C
A
3/8"
3/8", [email protected], 6@ 0.10,
[email protected] rto @.25 c/ext
N.F.Z. -1.10
2
C&M
Ø3/8" Indicados en Cuadro
A
D
VC- 2 (25X35)
A
Z-1
-
D
D
VC- 2 (25X35)
NO SE PERMITIRAN
EMPALMES DEL REFUERZO
SUPERIOR (NEGATIVO) EN
UNA LONGITUD DE 1/4
DE LUZ DE LA LOSA O
VIGA A CADA LADO DE
LA COLUMNA O APOYO
N.T.N. +0.00 (N.766)
E
C
A
N.P.T. +0.15
C1
VC-1 (25X40)
(cm)
30
8 mm
L
B
Z-1
COLUM
VIGAS
COLUMNAS
ESTRIBOS VIGA
N. +0.30
N.P.T. +0.15
N.T.N. +0.00 (N.766)
VC- 2 (25X35)
C1
Ry=6.00
ESTRIBOS
LOSAS
6 mm
ESTRIBOS COLUMNA
Z-1
Tp=1.0
Rx=6.00
TRASLAPES Y EMPALMES
E
C
Z-1
3
D
S=1.40
COEFICIENTE DE REDUCCION
6 Ø1/2" + 2Ø3/8"
N.F.Z. -1.10
(cm)
B
FACTOR DE SUELO
Ø 3/8":[email protected], [email protected],
[email protected], rto @.25 c/ext
VC-2
N. +0.30
VC- 2 (25X35)
D
VC- 2 (25X35)
VC- 2 (25X35)
A
65 Kg/cm2
NORMAS DE DISEÑO
LOSAS Y VIGAS
A
7.5 cm.
3 Ø 1/2"
VC-1
3 Ø 1/2"
N.F.Z. -1.10
H
C1
E
2.0 cm.
CIMENTACION
6 Ø1/2" + 2Ø3/8"
3 Ø1/2"
F
E
ESCALERAS
LAS UNIDADES DE ALBAÑILERIA SERAN DE 9x13x24 cm
ESTRIBOS
Ø
F
2.0 cm.
3 Ø 1/2"
Z-1
VC-1 (25X40)
4.0 cm.
ALIGERADO Y VIGAS CHATAS
ALBAÑILERIA
3/8", [email protected], 6@ 0.10,
[email protected] rto @.25 c/ext
3/8", [email protected], 6@ 0.10,
[email protected] rto @.25 c/ext
5
F
C1
2.5 cm.
COLUMNAS Y VIGAS PERALTADAS
3 Ø 1/2"
Ø 3/8" @.20
CL
Z-1
N.T.N. +0.00 (N.766)
2 Ø3/8"
C2
H
F
CUADRO DE VIGAS CONEXION
N.P.T. +0.15
N.P.T. +0.15
Z-1
A
fy = 4,200 Kg/cm²
2 Ø 5/8"
4 Ø5/8"+ 4Ø1/2"
N +0.30
CL
G
f'c = 175 Kg/cm²
f'c = 210 Kg/cm²
f'c = 100 kg/cm² + 30% PG (4" max.)
N. +0.30
N. +0.30
N.T.N. +0.00 (N.766)
VC- 2 (25X35)
G
C1
B-B
N.P.T. +0.15
H
SOBRECIMIENTOS
RESTO DE ELEMENTOS
fm (minimo)
C1
VC-1 (25X40)
1.10 (CEMENTO : HORMIGON)
ACERO
N.F.Z. -1.10
ESC.: 1:15
C
C2
4
4 Ø 1/2"
Z-1
A
Z-1
4 Ø 1/2"
2 Ø 3/8"
TIPO
C
C1
VC-1 (25X40)
B
D
Z-1
Z-1
A
3 Ø 1/2"
3 Ø 1/2"
N.T.N. +0.00 (N.766)
5
2 Ø 5/8"
SOLADO 4"
CIMIENTO CORRIDOS
ASTM A - 615 GRADO 60 CORRUGADO
B
C1
E
C
A
3 Ø1/2"
(VER ESTUDIO DE SUELOS)
CONCRETO
C
A
Z-1
3 Ø1/2"
σ= 1.10 Kg/cm2
Df =1.10 m
CL
C-2
2 Ø 5/8"
Z-1
VC-1 (25X40)
C
A
B
D
3/8", [email protected], 6@ 0.10,
[email protected] rto @.25 c/ext
3/8", [email protected], 6@ 0.10,
[email protected] rto @.25 c/ext
3/8", [email protected], 6@ 0.10,
[email protected] rto @.25 c/ext
8
C1
F
VC- 2 (25X35)
VC- 2 (25X35)
F
A
Z-1
VC- 2 (25X35)
8
Z-1
VC- 2 (25X35)
Z-1
F
VC- 2 (25X35)
F
CAPACIDAD ADMISIBLE DEL TERRENO
L
B
L
A
Solado de concreto
Dosif.: 1:10
1.00
CORTE TIPICO DE ZAPATA
ESCALA:
DIBUJO:
FECHA:
ESPECIALIDAD
INDICADA
MPT
30/03/2020
FORMATO
E-1 A1
REV.
0