High Frequency Solar Inverter Solar System PH1800 MPK Series Specification High Frequency Solar Inverter MODEL Feature: Pure sine wave output Built-in MPPT solar charge controller Selectable input voltage range for home appliances and personal computers Selectable charging current based on applications Configurable AC/Solar input priority via LCD setting Compatible to mains voltage or generator power Auto restart while AC is recovering Smart battery charger design to optimize battery performance Cold start function Parallel operation with up to 6 units (Available for MUST PH18-4K/5K MPK) Optional Remote Control Panel available Surge Power INVERTER OUTPUT BATTERY 4000VA/ 2400W 3200W 4000W 2000VA 4000VA 6000VA 8000VA 10000VA SOLAR CHARGER & CHARGER 230VAC±5% (Batt.Mode) 93% 90% 10ms(For Personal Computers) 20ms(For Home Appliances) 230VAC 170~280VAC(For Personal Computers) Selectable Voltage Range 90~280VAC(For Home Appliances) 50Hz/60Hz (Auto sensing) Nominal voltage 24VDC 48VDC Floating Charge Voltage 27VDC 54VDC Overcharge Protection 31VDC 60VDC Maximum PV Array Open Circuit Voltage 75VDC 145VDC 30~66VDC 60~115VDC Standby Power Consumption 2W Reted Power 600W 3000W Maximum Solar Charge Current 25A 60A Maximum Efficiency 98% 3 Maximum AC Charge Current 10A or 20A 4 Maximum Charge Current 25A 2 1 MECHANICAL SPECIFICATIONS PV panel 5 7 8 12 15 9 7 8 12 15 9 Model 14 13 10 6 11 4KVA-5KVA parallel model 10 6 1KVA-5KVA single model 1. LCD display 10. Battery input 2. Status indicator 11. Circuit breaker 3. Charging indicator 12. RS232 communication port 4. Fault indicator 13. Parallel communication cable (only for parallel model) 5. Function buttons 14. Current sharing cable (only for parallel model) 6. Power on/off switch 15. Dry contact 7. AC input 8. AC output 1KVA Generator 272*372*131 Net Weight(kg) 7.4 295*528*141 7.6 8.0 parallel installation guide for the details. -07- 12.5 13.5 5% to 95% Relativ Humidity (Non-condensing) Operating Temperature 0°C -55°C Storage Temperature -15°C -60°C External Battery pack Home Appliances 2KVA Back Panel 3KVA Load(VA) Backup Time@24V 100Ah(min) Backup Time@24V 200Ah(min) 200 766 1610 600 198 503 1000 112 269 200 766 1610 Model 1KVA 2KVA Load(VA) Backup Time@48V 100Ah(min) Backup Time@48V 200Ah(min) 100 2529 5058 500 482 1035 1000 186 471 200 1581 3161 1000 268 615 2000 106 257 300 1054 2107 402 1000 112 269 2000 50 112 1500 159 300 449 1100 3000 63 155 1500 68 164 400 766 1610 3000 28 67 2000 112 269 4000 50 112 500 613 1288 2500 90 215 5000 40 90 3KVA 4KVA 9. PV input NOTE: For parallel model installation and operation, please check separate 120A 30A Dimension,W*H*D(mm) Approximate Back-up Time Table Utility 11 60A 20A or 30A Humidity OTHER 5000VA/ Pure sine wave Waveform PV Array MPPT Voltage Range AC Solar System Connection 3000VA/ 1600W Frequency Range uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible applications. 2000VA/ 800W Voltage AC PH18-5K MPK 1000VA/ Transfer Time INPUT PH18-4K MPK 48VDC AC Voltage Regulation Inverter Efficiency (Peak) This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different PH18-3K MPK 24VDC Reted Power Introduction: LCD Display Information PH18-2K MPK PH18-1K MPK Default Battery System Voltage 5KVA -08-