High Frequency Solar Inverter
Solar System
PH1800 MPK Series
Specification
High Frequency Solar Inverter
MODEL
Feature:
Pure sine wave output
Built-in MPPT solar charge controller
Selectable input voltage range for home appliances
and personal computers
Selectable charging current based on applications
Configurable AC/Solar input priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Smart battery charger design to optimize battery
performance
Cold start function
Parallel operation with up to 6 units (Available for
MUST PH18-4K/5K MPK)
Optional Remote Control Panel available
Surge Power
INVERTER
OUTPUT
BATTERY
4000VA/
2400W
3200W
4000W
2000VA
4000VA
6000VA
8000VA
10000VA
SOLAR
CHARGER
&
CHARGER
230VAC±5%
(Batt.Mode)
93%
90%
10ms(For Personal Computers)
20ms(For Home Appliances)
230VAC
170~280VAC(For Personal Computers)
Selectable Voltage Range
90~280VAC(For Home Appliances)
50Hz/60Hz (Auto sensing)
Nominal voltage
24VDC
48VDC
Floating Charge Voltage
27VDC
54VDC
Overcharge Protection
31VDC
60VDC
Maximum PV Array
Open Circuit Voltage
75VDC
145VDC
30~66VDC
60~115VDC
Standby Power
Consumption
2W
Reted Power
600W
3000W
Maximum Solar Charge
Current
25A
60A
Maximum Efficiency
98%
3
Maximum AC Charge
Current
10A or 20A
4
Maximum Charge Current
25A
2
1
MECHANICAL
SPECIFICATIONS
PV panel
5
7
8
12 15
9
7
8
12 15
9
Model
14
13
10
6
11
4KVA-5KVA parallel model
10
6
1KVA-5KVA single model
1. LCD display
10. Battery input
2. Status indicator
11. Circuit breaker
3. Charging indicator
12. RS232 communication port
4. Fault indicator
13. Parallel communication cable (only for parallel model)
5. Function buttons
14. Current sharing cable (only for parallel model)
6. Power on/off switch
15. Dry contact
7. AC input
8. AC output
1KVA
Generator
272*372*131
Net Weight(kg)
7.4
295*528*141
7.6
8.0
parallel installation guide for the details.
-07-
12.5
13.5
5% to 95% Relativ Humidity (Non-condensing)
Operating Temperature
0°C -55°C
Storage Temperature
-15°C -60°C
External
Battery pack
Home Appliances
2KVA
Back Panel
3KVA
Load(VA) Backup Time@24V 100Ah(min) Backup Time@24V 200Ah(min)
200
766
1610
600
198
503
1000
112
269
200
766
1610
Model
1KVA
2KVA
Load(VA) Backup Time@48V 100Ah(min) Backup Time@48V 200Ah(min)
100
2529
5058
500
482
1035
1000
186
471
200
1581
3161
1000
268
615
2000
106
257
300
1054
2107
402
1000
112
269
2000
50
112
1500
159
300
449
1100
3000
63
155
1500
68
164
400
766
1610
3000
28
67
2000
112
269
4000
50
112
500
613
1288
2500
90
215
5000
40
90
3KVA
4KVA
9. PV input
NOTE: For parallel model installation and operation, please check separate
120A
30A
Dimension,W*H*D(mm)
Approximate Back-up Time Table
Utility
11
60A
20A or 30A
Humidity
OTHER
5000VA/
Pure sine wave
Waveform
PV Array MPPT Voltage
Range
AC
Solar System Connection
3000VA/
1600W
Frequency Range
uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible
applications.
2000VA/
800W
Voltage
AC
PH18-5K MPK
1000VA/
Transfer Time
INPUT
PH18-4K MPK
48VDC
AC Voltage Regulation
Inverter Efficiency (Peak)
This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer
button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different
PH18-3K MPK
24VDC
Reted Power
Introduction:
LCD Display Information
PH18-2K MPK
PH18-1K MPK
Default Battery System Voltage
5KVA
-08-
Descargar