Subido por Fabian Heredia

Check Valves 2016 v4

Anuncio
WWW.FPPI.COM
UL LISTED AND FM APPROVED
LISTED VALVE NOW
AVAILABLE IN
1½” SIZE
•
Brass Body* (C38000) for superior corrosion resistance
•
Listed valves available in the following sizes: 1 ½”**, 2”, 2 ½”, 3” and 4”
•
Available Grooved, Threaded, or Thread by Groove reducing the need for additional
fittings and minimizing installation time.
•
Pressure rated to up to 300 PSI
•
Tapped and plugged for easy use of accessories such as ball drips or gauges
*Contains lead. Not for use in water systems intended for human consumption.
**1 1/2” size is UL/ULc listed only
3198 LIONSHEAD AVE
CARLSBAD, CA 92010
+ 1 (760) 599-1168
+ 1 (800) 344-1822
+ 1 (800) 344-3775 FAX
TrimFit® Check Valves
UL Listed and FM Approved
Dimensions
WIDTH
LENGTH
LENGTH
SIZE #
ITEM #
SIZE
ITEM
(MM)
LENGTH
WIDTH
CONFIGURATION
(MM)
(MM)
1 1/2”
1 1/2”*
09-574-00
09-574-00
176
176
MNPT
X GRV
105
61 105
15/16
1/2”
1 1/2”
1 1/2”*
09-575-00
09-575-00
154
154
MNPT
X FNPT
105
1 1/2”
1 1/2”*
09-576-00
09-576-00
176
1 1/2”
1 1/2”*
09-577-00
2”
WIDTH
LENGTH
LENGTH
WIDTH
SIZE
ITEM
(MM)
(IN) #
(IN)
(IN)
WIDTH
LENGTH
(IN)
(MM)
WIDTH
(MM)
LENGTH
(IN)
WID
(IN
64 15/16
09-574-00
1/8
4176
1/8
105
6 15/16
41
6
1 105
1/2”
1/16
64 1/8
1/16
09-575-00
4154
1/8
105
6 1/16
41
176
GRV105
X GRV
61 105
15/16
1/2”
6415/16
09-576-00
1/8
4176
1/8
105
6 15/16
41
09-577-00
150
150
FNPT105
X FNPT
5
1 105
1/2”
9/16
54 1/8
9/16
09-577-00
4150
1/8
105
5 9/16
41
2”
09-568-00
09-568-00
157
157
MNPT
X GRV
105
6105
2”
1/4
1/4
09-568-00
461/8
4157
1/8
105
6 1/4
41
2”
2”
09-570-00
09-570-00
146
146
MNPT
X FNPT
105
5105
2”3/4
3/4
09-570-00
45 1/8
4146
1/8
105
5 3/4
41
2”
2”
09-572-00
09-572-00
157
157
GRV105
X GRV
6105
2”
1/4
1/4
09-572-00
461/8
4157
1/8
105
6 1/4
41
2 1/2”
2 1/2”
09-562-00
09-562-00
176
176
MNPT
X GRV
105
62 105
15/16
1/2”
6415/16
09-562-00
1/8
4176
1/8
105
6 15/16
41
2 1/2”
2 1/2”
09-564-00
09-564-00
159
159
MNPT
X FNPT
105
26105
1/2”
1/4
1/4
09-564-00
46 1/8
4159
1/8
105
6 1/4
41
2 1/2”
2 1/2”
09-566-00
09-566-00
176
176
GRV105
X GRV
62 105
15/16
1/2”
6415/16
09-566-00
1/8
4176
1/8
105
6 15/16
41
3”
3”
09-556-00
09-556-00
173
173
MNPT
X GRV
128
6 128
13/16
3”
6513/16
09-556-00
1/8
5173
1/8
128
6 13/16
51
3”
3”
09-558-00
09-558-00
167
167
MNPT
X FNPT
128
6128
3”5/8
5/8
09-558-00
56 1/8
5167
1/8
128
6 5/8
51
3”
3”
09-560-00
09-560-00
173
173
GRV128
X GRV
6 128
13/16
3”
6513/16
09-560-00
1/8
5173
1/8
128
6 13/16
51
4”
4”
09-550-00
09-550-00
206
206
MNPT
X GRV
142
8142
4”1/8
1/8
09-550-00
58 5/8
5206
5/8
142
8 1/8
5 5
4”
4”
09-552-00
09-552-00
202
202
MNPT
X FNPT
142
142
4”
8
8
09-552-00
5 5/8
5202
5/8
142
8
5 5
4”
4”
09-554-00
09-554-00
202
202
GRV142
X GRV
142
4”
8
8
09-554-00
5 5/8
5202
5/8
142
8
5 5
*UL Listed Only
3198 LIONSHEAD AVE
CARLSBAD, CA 92010
+ 1 (760) 599-1168
+ 1 (800) 344-1822
+ 1 (800) 344-3775 FAX
© 2016 Fire Protection Products, Inc.
WWW.FPPI.COM
The information contained herein is produced in good faith and is believed to be reliable but is provided for guidance and
information purposes only. FPPI and its agents cannot assume liability or responsibility for results obtained in the use or
misuse of its product by persons whose methods and qualifications are outside and beyond our control. It is the user’s
responsibility to determine the suitability of, methods of use, preparation prior to use, and appropriate installation for all
products purchased from FPPI. It is the user’s sole responsibility to observe and adapt such precautions as may be advisable
or necessary for the protection of personnel and property in the handling and use of any of our products.
TrimFit® Check Valves
Installation Instructions
Description
Check valves feature cast brass* bodies with a spring loaded clapper assembly making
this valve suitable for vertical or horizontal installations. Features metal faced clapper
with O-ring seat. Rated to 300 psi. Valve bodies are tapped and plugged 1/2” IPS for
additional equipment such as a ball drip valve when used in conjunction with a Fire
Department Connection or a pressure gauge when used in a supply line.
Installation
Install in accordance with approved installation practices. Use an approved
thread sealant such as PipeFit Thread Sealing Paste with PTFE on all threaded
connections. Make sure that proper lubrication has been applied to groove
coupling gaskets for groove end valves.
DO NOT OVER TIGHTEN THREADED CONNECTIONS. OVERTIGHTENING MAY
CAUSE DISTORTION OF THE BODY AND THREADS OF THE VALVE LEADING
TO IMPROPER PERFORMANCE AND PRODUCT FAILURE.
Specifications
Material:
Cast Brass* (C38000)
Pressure Rated:
300psi
Size:
11/2” IPS**
2” IPS
21/2” IPS
3” IPS
4” IPS
Configurations:
MNPT x GRV
MNPT x FNPT
GRV x GRV
FNPT x FNPT 1 ½” only 
*Contains lead. Not for use in
water systems intended for
human consumption.
**1 ½” size is UL/ULc listed only
The information contained herein is produced in good faith and is believed to be reliable but is provided for guidance and
information purposes only. FPPI and its agents cannot assume liability or responsibility for results obtained in the use or
misuse of its product by persons whose methods and qualifications are outside and beyond our control. It is the user’s
responsibility to determine the suitability of, methods of use, preparation prior to use, and appropriate installation for
all products purchased from FPPI. It is the user’s sole responsibility to observe and adapt such precautions as may be
advisable or necessary for the protection of personnel and property in the handling and use of any of our products.
3198 LIONSHEAD AVE
CARLSBAD, CA 92010
+ 1 (760) 599-1168
+ 1 (800) 344-1822
+ 1 (800) 344-3775 FAX
© 2016 Fire Protection Products, Inc.
WWW.FPPI.COM
Descargar