Subido por Raynier Delgado

Haskel Liquid Pumps Booklet Web

Anuncio
Pressure on Demand
Pneumatic Driven Liquid Pumps
LP-GL 04/17
High Pressure
Haskel pneumatic driven liquid pumps are designed to provide a safe, reliable
and economical, source of hydraulic pressure.
This brochure introduces our pneumatic driven liquid pump range. Visit our
website at www.haskel.com for more information or to locate a distributor.
Why Use Haskel Pneumatic Driven Pumps?
Our pumps offer many advantages over electrically driven pumps:
•
•
•
•
•
•
•
•
Safe pneumatic operation – no heat, flame or spark risk
Up to 100,000 psi (7000 bar) capability
Infinitely variable cycling speed
Stall feature at pre-determined pressure to hold that
pressure without consuming power
Problem-free stop/start applications
Easily automated – many modification and control options
Suitable for most liquids and liquefied gases
Alternative gas drive options – sour gas, natural gas,
boil off gases, nitrogen
Applications include:
•
•
•
•
•
•
•
•
•
Pressure testing
Work holding/power clamping
Jacking/lifting
Valve actuator control
Hydraulic cylinder actuation
Press safety overload devices
Roller tensioning
Metering
Precision lubrication and
spraying
• Liquefied gas transfer
2
www.haskel.com
• No need for air line lubrication – saves costs and
prevents contamination
• Robust, reliable, compact and easy to maintain proven
design
• Unbalanced cycling spool provides immediate response to
pressure changes
• Also available in standard, or custom built power pac
configurations
• Excellent worldwide service for spares and repairs
• ATEX approved
• CE certified
Pressure and Flow on Demand
This guide will help you to pre-select the pump ideally suited
for your application. If you have specific questions, however,
we urge you to provide Haskel with the operational details
of your application. We will recommend a model and any
corresponding accessories.
Output Horsepower Ratings
The pumps are categorized on their horsepower ratings (see
pages 6-7). These are approximate and peak at 100 psi (7
bar), assuming adequate drive, pressure and volume. Peak
horsepower is at about 75% nominal ratio x drive pressure, i.e.
100:1 pump @ 100 psi air drive peaks at 100 x 100 = 10000 x 0.75
psi = 7500 psi (517 bar) hydraulic pressure.
Double and Triple Air
Head Pumps
Performance can be extended for the 1.5 hp pumps by stacking
air pistons without changing the hydraulic piston. Haskel
multi-head pumps consume less air than competitive single
head pumps of the same area, as only one head is pressurized
on the return stroke; e.g., on a 1.5 hp pump additional heads
can raise performance to 2 hp.
Double air head pumps are identified by the last digit 2 in the
pump model number. Thus, a nominal 50:1 ratio pump with two
air heads is described as a 52. Similarly, a triple air head pump
is identified with a last digit 3. Thus, a 900 ratio pump with three
air heads is described as a 903.
Single Drive Head Pump
25.9 sq in (167 sq cm)
Operation
The pumps automatically reciprocate
on a differential piston principle. A large
piston driven by relatively low pressure
drive acts directly upon a smaller
hydraulic piston.
The nominal ratio between piston sizes
is indicated in the model coding and
approximates to the maximum working
pressure. The actual ratio is about
15% above nominal so that the pump
continues to cycle when drive pressure
equals nominal ratio. Initially, the pump
will cycle at maximum speed acting as a
transfer pump to pressurize downstream.
It will cycle at a slower rate as the
fluid meets resistance until it stalls
at maximum output pressure. When
a pressure drop downstream occurs,
it will recycle as necessary in an
effort to maintain maximum pressure.
Stall pressure is achieved when
the outlet pressure rises and offers
more resistance to the reciprocating
differential piston assembly. The piston
assembly then stalls when the forces
balance, e.g. when drive pressure x drive
piston area equals outlet (stall) pressure
x driven hydraulic plunger area. The
pump design is sensitive to very small
pressure drops due to the low frictional
resistance of the large diameter drive
piston and hydraulic piston seals.
0.65 sq in (4 sq cm)
Therefore, actual ratio = 40:1
Nominal Ratio = 35:1
Double Air Head Pump
Area 25.9 sq in (167 sq cm)
Area 25.2 sq in (163 sq cm)
Area .65 sq in (4 sq cm)
Therefore, actual ratio = 79:1
Nominal Ratio = 72:1*
Triple Air Head Pump
Area 25.9 sq in (167 sq cm)
Area 25.2 sq in (163 sq cm)
Area 25.2 sq in (163 sq cm)
Area .65 sq in (4 sq cm)
Therefore, actual ratio = 118:1
Nominal Ratio = 103:1**
Nominal Ratio
* (2) Indicates Double Drive Piston
** (3) Indicates Triple Drive Piston
www.haskel.com
3
1. Drive
Section
2. Hydraulic
Check
Valves
Anatomy of a Pneumatic Driven Pump
1. Drive Section
The piston, complete with “O” ring seal, operates in an epoxy filled,
fiberglass wound barrel, the diameter of which is constant throughout
a given series of pumps. Drive media forces the piston down on the
compression stroke and raises it on the suction stroke (M series have a
spring return). The piston is pre-lubricated during assembly and therefore
no air line lubricator is necessary.
2. Hydraulic Section/Check Valves
The drive piston is linked and connected to the hydraulic plunger/piston
in the hydraulic section. Outlet flow and pressure are determined by the
area of the hydraulic piston head, its nominal ratio with the drive piston
head, and drive pressure. On the down stroke, liquid in the hydraulic
section is forced under compression through the outlet check valve.
Fresh liquid is induced via the inlet check valve on the return stroke.
These check valves control the flow of liquid through the hydraulic
section. They are spring-loaded and have a very low cracking pressure,
allowing maximum opening on the induction stroke. The pressure of
hydraulic fluid on the down stroke closes the inlet check valve and acts
against the spring to open the outlet check valve.
3. Drive Cycling Valve
This is a pilot-operated, unbalanced, lightweight spool, which directs
drive pressure, first to the top of the drive piston, and then to the
underside to reciprocate the piston (cycle). It actuates via pilot valves at
the top and the bottom of the stroke, which causes the unbalanced spool
to shift and reciprocate the piston.
3. Drive
Cycling
Valve
4. Hydraulic
Seal
4
www.haskel.com
4. Hydraulic Seal/Check Valves
This is one of the few wear parts. Its function is to allow the hydraulic
piston to reciprocate without passing fluid into the drive section. The liquid,
its pressure and its temperature determine seal specification. A distance
piece can be incorporated between drive and hydraulic sections for
complete contamination-free operation on most Haskel pumps.
WETTED MATERIALS OF CONSTRUCTION AND SERVICES
.33 hp
MODEL
M
1
MS
1, 2
29723
1.5 hp
.75hp
MDSTV
1, 2, 3, 5, 6
1, 2, 3, 4, 5, 6
NON METALLICS
PUMP SECTION
PLUNGERS
Cad plated steel, Aluminum & SS
416 SS
Urethane, PTFE, Buna
All SS
316 SS
UHMWPE, PTFE, Buna
Separation - All SS
Hard Chrome Plated 15.5PH SS + Dichronite
UHMWPE, PTFE, Ryton
Stainless Steel and Aluminum
303 Stainless Steel
Viton, PTFE
4B-14 thru -37
1, 2
Aluminum
Aluminum(Hard coated)
UHWMPE, Buna
4B-55 thru -100
1, 2
303 SS
440 C. SS
UHWMPE, Buna
Nickel Plated Steel & SS
440C SS
Urethane, Buna N, PTFE
All SS
440C SS
UHMWPE, Buna, PTFE, Ryton
Separation - All SS
440OC SS Hard Chrome Plated
UHMWPE, Viton, PTFE, Ryton
Nickel Plated Steel & SS
Stellite 15-5PH SS
UHMWPE, Buna N
All SS
Stellite 15-5PH SS
UHMWPE, Buna N
Separation - All SS
Stellite 15-5PH SS
UHMWPE, Buna N
Aluminum, Bronze & SS
15.5PH SS
PTFE, Viton
Separation - Aluminum, Bronze & SS
15.5PH SS
PTFE, Viton
1, 2, 3, 4, 5, 6
Separation - All SS
17.4PH SS
PTFE, Viton
DSTV
1, 2, 3, 4, 5
Separation - All SS
440C SS Hard Chrome Plated
PTFE, Viton
DTN
1, 2, 5
Stainless Steel, Aluminum
300 Series SS
Neopreen, PTFE
AW
1
Nickel Plated Steel & SS
440C SS
Urethane, Buna N, PTFE
AFD
1
Nickel Plated Steel & SS
416 SS
UHMWPE, Buna, PTFE, Ryton
DFD
1, 3, 5
Nickel Plated Steel & SS
416 SS
UHMWPE, Viton, PTFE, Rtyon
ASFD
1, 2
All SS
15.5PH SS
UHMWPE, Viton, PTFE, Rtyon
ASF
1, 2
All SS
440C SS
UHMWPE, Viton, PTFE, Rtyon
AW
1
ASF
1, 2
DSF
1, 2, 3, 5, 6
HF
1
HSF
1, 2
DSHF
1, 2, 5, 6
ATV
1, 2
DTV
1, 2, 5
DSTV-1.5
2 thru 3hp
WETTED MATERIALS
SERVICES
(refer to pg. 17)
DSFD
1, 2, 3, 5, 6
Separation - All SS
15.5PH SS
UHMWPE, Viton, PTFE, Rtyon
DSF
1, 2, 3, 5, 6
Separation - All SS
440C SS Hard chrome plated
UHMWPE, Viton, PTFE, Rtyon
Nickel Plated Steel & SS
Stellite 15-5PH SS*
UHMWPE, Buna N
All SS
Stellite 15-5PH SS*
UHMWPE, Buna N
HF
1
HSF
1, 2
DSHF
1, 2, 5, 6
Separation - All SS
Stellite 15-5PH SS*
UHMWPE, Buna N
DSXHF
1, 2, 5, 6
Separation - All SS
Stellite 15-5PH SS
UHMWPE, Buna N
DSXHW
1, 2
Separation - All SS
Stellite 15-5PH SS
Urethane, PTFE
DSTV-1.5
1, 2, 3, 4, 5, 6
Separation - All SS
17.4PH SS
PTFE, Viton
1, 2, 3, 4, 5
Separation - All SS
440C SS Hard chrome plated
PTFE, Viton
Nickel Plated Steel, SS & Bronze
Hard chrome plated 15.5PH SS
Urethane, Buna N, PTFE
All SS & Bronze
Hard chrome plated 15.5PH SS
UHMWPE, Viton, PTFE, Ryton
DSTV
6 hp
*Except -202 ratio is chrome plated 440 SS
GW
1
GSF
1, 2
DGSF
1, 2, 3, 5, 6
Separation- All SS & Bronze
Hard chrome plated 15.5PH SS
UHMWPE, Viton, PTFE, Ryton
DGSTV
1, 2, 3, 4, 5
Separation- All SS & Bronze
Hard chrome plated 15.5PH SS
Viton, PTFE, Ryton
Nickel Plated Steel & SS
15.5PH SS Hard chrome plate optional
Urethane, Buna N, PTFE
All SS & Bronze
15.5PH SS Hard chrome plate optional
UHMWPE, Buena N, PTFE, Ryton
Separation- Nickel Plated Steel & SS
15.5PH SS hard chrome plate optional
UHMWPE, Viton, PTFE, Ryton
GWD
1
GSFD
1, 2
DGFD
1, 3, 5
DGSFD
1, 2, 3, 4, 5, 6
Separation- All SS & Bronze
15.5PH SS Hard chrome plate optional
UHMWPE, Viton, PTFE, Ryton
1, 2, 3. 4, 5
Separation- All SS & Bronze
17.4PH SS Hard chrome plate optional
PTFE, Viton
DGSTVD
8 hp
8SFD
All SS & Bronze*
Hard chrome plated 15.5PH SS
UHMWPE, Viton, PTFE, Ryton
1, 2 ,3 ,5, 6
Separation- All SS & Bronze
15.5PH SS Hard chrome
UHMWPE, Viton, PTFE, Ryton
8DTVD
1, 2, 3, 4, 5, 6
Separation- All SS & Bronze
15.5PH SS Hard chrome
PTFE, Viton
8HSFD
1, 2
All SS & Bronze*
17.4PH SS
UHMWPE, Viton, PTFE, Ryton
1, 2, 3, 5, 6
All SS & Bronze*
15-5 PH SS Hard chrome
Viton, PTFE
1, 2 ,6
All SS & Bronze*
15-5 PH SS Hard chrome
PTFE, Viton, UHMWPE
D14STD-125
1, 2, 3, 4, 5A
All SS & Bronze
Hard chrome plated 440C SS
PTFE, Viton
D14STD-315
1, 2, 3, 4, 5A
All SS & Bronze
Hard chrome plated 440C SS
PTFE, Viton
D14SFD-125
1, 2, 3, 5A, 6
All SS & Bronze
Tungston Carbide Coated 15.5PH SS
UHMWPE, Viton, PTFE, Ryton
D14SFD-315
1, 2, 3, 5A 6
All SS & Bronze
Tungston Carbide Coated 15.5PH SS
UHMWPE, Viton, PTFE, Ryton
8DSTVD
8SFD2
10 hp
1, 2
8DSFD
www.haskel.com
5
Power
Air Head
Max Air
Performance and Specification Overview
Maximum Rated Output Pressure
Pump Model Code
0.33 hp
Single
Single
0.75 hp
125 psi/8.6 bar
100 psi/7 bar
1.5 hp
Single
150 psi/10.5 bar
cu in/min
l/min
-14
-30
-37
-55
-100
16
34
42
63
114
1500
3200
3800
6000
10600
103
221
262
414
731
1500
3200
3800
6000
10600
103
221
262
414
731
0.9
0.43
0.35
0.22
0.13
14.7
7.0
5.7
3.6
2.0
428
204
166
105
62
7.01
3.35
2.72
1.71
1.01
-1.5
-4
-B10
-B15
-25
-35
-60
-100
-150
-151
-225
-300
-450
1.6
4.6
11.5
17
29
40
69
115
173
173
260
345
533
240
690
1600
2400
4000
5700
9800
15000
15000
25000
30000
30000
45000
17
48
110
165
276
393
676
1034
1034
1724
2069
2069
3103
300
1200
1600
2400
4000
5700
9800
16500
20000
25000
37000
50000
45000
21
83
110
165
276
393
676
1138
1379
1724
2552
3448
3103
31.90
20.00
4.05
2.70
1.62
1.16
0.67
0.41
0.27
0.27
0.18
0.14
0.0
513
328
66.4
44.3
26.6
19.0
11.0
6.7
4.5
4.5
3.0
2.3
1.5
5104
3200
1215
810
486
348
201
123
81
81
41
32
20
83.6
52.4
19.9
13.3
8.0
5.7
3.3
2.0
1.3
1.3
0.7
0.5
0.3
-8
-B22
-B32
-52
-72
-122
-202
-302
-452
-602
9.2
23
34
57
80
138
230
346
520
690
850
3200
4800
5000
11000
15000
30000
30000
30000
30000
59
221
331
345
759
1034
2069
2069
2069
2069
1200
3200
4800
8000
11000
19000
33000
50000
70000
75000
83
221
331
552
759
1310
2276
3448
4828
5172
20
4.05
2.70
1.62
1.16
0.67
0.41
0.27
0.18
0.14
328
66.4
44.3
26.6
19.0
11.0
6.7
4.5
3.0
2.3
3200
1215
810
488
348
201
92
61
41
32
52.4
19.9
13.3
8.0
5.7
3.3
1.5
1.0
0.7
0.5
DSXHW
-683
-903
-1373
780
1038
1575
30000
30000
30000
2069
2069
2069
70000
75000
100000
4828
5172
6897
0.18
0.14
0.086
3.0
2.3
1.4
25
20
12
0.41
0.33
0.197
AFD-DFD-ASFD-DSFD
-B60
69
6500
448
6500
448
1.34
2.2
369
6.0
ASFD
-10
-15
-25
-35
-60
-100
-150
-202
11.5
17
29
40
69
115
173
230
1600
2400
4000
5700
9800
15000
15000
30000
110
165
276
393
676
1034
1034
2069
1600
2400
4000
5700
9800
16500
20000
33000
110
165
276
393
676
1138
1379
2276
8.10
5.40
3.24
2.32
1.34
0.82
0.54
0.82
133
89
53.6
38.0
22.0
13.4
9.0
13.4
1823
1215
729
522
302
185
122
144
29.9
19.9
11.9
8.6
4.9
3.0
2.0
2.4
-12
-35
-60
-100
14.8
40.3
69
115
1850
4375
7500
8000
128
302
517
552
4000
4375
7500
10000
276
302
517
690
15.9
6.0
3.5
2.1
260
98
57
34
5009
1890
1103
662
82.1
31.0
18.1
10.8
-25
-40
-65
-100
-225
-55
-88
-224
27.5
43.5
73
112
253
55
88
225
3575
6000
10000
10000
25000
5500
8800
25000
246
414
690
690
1724
379
607
1724
4000
6000
10000
10000
25000
7200
10000
25000
276
414
690
690
1724
497
690
1724
14.0
8.90
5.40
3.52
1.56
14.14
8.84
3.53
229
145
88
58
26
232
145
58
2660
1691
1026
669
296
1900
1182
476
43.5
28.0
17.0
11.0
5.0
31.1
19.36
7.6
-125
-315
138
347
16000
36000
1103
2483
16000
36000
1103
2483
8.80
3.50
144.2
57.4
704
280
11.5
4.6
M, MS, 29723
4B
AW, ASF, DSF, DSTV
2 hp
2 hp
2.2
3 hp
ml
8.30
6.00
3.83
2.13
1.28
0.64
0.42
0.29
0.29
0.22
DSXHF
DXHF, DSXHF
GWD, GSFD, DGSFD, DGSTVD
6 hp
cu in
506
366
234
130
78
39
25
18
18
14
HF, HSF, DSHF
GW, GSF, DGSF,
DGSTV
8SFD, 8DSFD, 8DSTVD
8SFD
8 hp
bar
13.6
9.8
5.9
3.3
2.0
1.0
0.60
0.40
0.40
0.34
ATV
8DSFD
8HSFD
8SFD2
(Double Air Drive Piston Models)
10 hp
psi
0.83
0.60
0.36
0.20
0.12
0.06
0.039
0.023
0.023
0.021
HF
Double
bar
43
62
103
179
310
607
931
1034
1034
1723
HF, HSF, DSHF
Triple
psi
625
900
1500
2600
4500
8800
13500
15000
10000
25000
AW, ASF, DSF, DSTV
100 psi/7 bar
Maximum Flow
43
62
103
179
310
607
931
1034
1034
1380
DSTV
ATV, DTN, DTV
150 psi/10.5 bar
Displacement/Cycle
625
900
1500
2600
4500
8800
13500
15000
10000
20000
M, MS
29723
MS
Single
Intermittent
5.6
7.8
14
25
41
82
126
217
217
220
M, MS
125 psi/8.6 bar
Continuous
-5
-7
-12
-21
-36
-71
-110
-188
-188
-220
M, MDSTV
6
Ratio Dash Actual Area
no.
Ratio
D14STD, D14SFD
Typical Performance using 100 psi (7 bar) Air drive
Outlet Pressure
Outlet Flow
Outlet Pressure
Outlet Flow
psi
bar
cu in/min
l/min
psi
bar
cu in/min
l/min
225
300
700
1500
1700
2450
3000
7500
5000
5000
7500
15.5
21
48
103
117
169
207
517
345
345
517
500
350
200
90
70
tbd
40
20
18
18
15
8.20
5.70
3.28
1.48
1.15
tbd
0.64
0.33
0.30
0.30
0.24
415
600
1125
2000
3100
4500
6000
10000
10000
10000
15000
29
41
78
138
214
310
414
690
690
690
1034
249
160
100
48.9
39.6
tbd
19
8.5
14
14
12
4.09
2.6
1.64
0.8
0.65
tbd
0.31
0.14
0.23
0.23
0.2
700
1500
1750
2000
5000
48
103
121
138
345
400
200
170
110
57
6.55
3.28
2.78
1.80
0.93
1450
3000
3500
5000
10000
100
207
241
345
690
61
62
82
66
26
1.00
1.00
1.33
1.08
0.43
50
100
400
750
1000
2000
3000
4000
7000
7000
7500
15000
36000
3
7
28
52
69
138
207
276
483
483
517
1034
2483
5000
1953
1000
598
403
350
152
100
59.7
59.7
39.6
29.9
14.6
81.9
32
16.4
9.8
6.6
4.1
2.5
1.64
0.98
0.98
0.65
0.49
0.24
150
400
990
1600
2500
3600
6200
10000
15000
15000
24000
27000
45000
10
28
68
110
172
248
427
690
1034
1034
1655
1862
3103
1000
750
500
200
195
98
50
24.4
29.9
29.9
9.8
20.1
9.2
16.4
12.3
8.19
3.28
3.2
1.6
0.82
0.4
0.49
0.49
0.16
0.33
0.15
200
400
700
1900
2000
4000
7000
10000
10000
15000
14
28
48
131
138
276
483
690
690
1034
1953
799
500
299
226
122
91.5
45.2
34.8
24.4
32
13.1
8.2
4.9
3.7
2.0
1.5
0.7
0.6
0.4
800
2100
3000
5000
7500
12000
20000
30000
40000
50000
28
145
207
345
517
828
1379
2069
2759
3448
750
200
152
98
50
40.2
20.1
15.2
15.2
12.2
12.3
3.28
2.50
1.60
0.82
0.66
0.33
0.25
0.25
0.2
15000
15000
16000
1034
1034
1103
19.5
15.9
9.2
0.32
0.26
0.15
60000
70000
90000
4138
4828
6207
4.9
5.5
3.1
0.08
0.09
0.05
1000
69
348
5.7
5500
379
152
2.5
500
750
1000
1500
3000
5000
7500
10000
34
52
69
1034
138
345
517
690
1520
1030
662
465
248
151
103
63
24.9
16.9
10.9
7.6
4.1
2.5
2.0
1.0
1000
1500
2500
3500
6000
10000
15000
20000
69
103
172
248
414
690
1034
1379
380
260
162
100
56
41
27
47
6.22
4.26
2.66
1.64
0.92
0.67
0.44
0.77
200
1000
2000
2000
14
69
138
138
5004
1770
976
573
82
29
16
9.4
1200
3500
5500
10000
83
241
379
690
1454
600
397
195
24
9.8
6.5
3.2
1000
2000
3000
5000
10000
2500
4000
10000
69
138
207
345
690
172
276
690
2400
1420
880
555
270
1230
850
315
39.3
23.2
14.4
9.1
4.4
20.1
13.9
5.2
2500
4000
6000
10000
20000
4000
5000
18500
172
276
414
690
1379
276
345
1276
280
200
310
163
144
675
800
140
4.6
3.27
5.08
2.67
2.36
11
13.1
2.3
8000
15000
552
1034
488
238
8.0
3.9
12000
30000
828
2069
195
79.3
3.2
1.3
Pump Selection Information
All Haskel pumps are identified by letters coding the type of
pump, followed by a number indicating the practical working
ratio of the drive area to the hydraulic plunger area. These
letters are explained in the chart below.
Pump Model Letter Coding
M
.875” stroke .33 hp miniature pump series
S
Stainless steel hydraulic piston and body
29723
.33 hp Chemical Pump
D (Prefix)
Pump incorporates a Distance Piece
D (Suffix)
Double Acting pump
4B
1” stroke .75 hp pump series (bottom inlet only)
A
2” stroke 1.5 + 2 hp pump series
H
2” stroke 1.5 + 2 hp High Pressure pump series
XH
2” stroke 1.5 + 2 hp Extreme High Pressure pump series
G
4.5” stroke 6 hp pump series
B
4.5” stroke 8 hp pump or booster series
14
4” stroke 10 hp pump series
W
Polyurethane U-cup dynamic seal
F
UHMWPE (Ultra-high Molecular Weight Polyethylene Dynamic Seal
T
Reinforced Teflon® dynamic seal
V
Viton® o-ring static seal
Guidelines for 24/7 Continuous
Duty Applications for Maximizing
Seal Life Performance
Pump Series
Maximum Cycles per Minute
0.3 hp
90 cpm
0.75 hp
80 cpm
1.5, 2.0 and 2.2 hp
(Single and Double Drive Piston)
60 cpm
2.0 hp (Triple Drive Piston)
60 cpm
3.0 hp
60 cpm
6.0 hp
40 cpm
8.0 hp
40 cpm
10.0 hp
40 cpm
www.haskel.com
7
.33 hp (.25 kW) M Series Pump Models
Model
Nominal
Ratio
Maximum Working Pressure
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
Displacement
per Cycle
M,
MDSTV
-5
625 psi (43 bar)
M, MS
-7
900 psi (62 bar)
.6 cu in (9.8 ml)
-12
1500 psi (103 bar)
.36 cu in (5.9 ml)
M, MS,
-21
2600 psi (179 bar)
.2 cu in (3.3 ml)
29723*
-36
4500 psi (310 bar)
.12 cu in (2.0 ml)
-71
8800 psi (607 bar)
.06 cu in (1.0 ml)
-110
13500 psi (931 bar)
.039 cu in (0.6 ml)
-188
15000 psi (1034 bar)
.023 cu in (.4 ml)
-220
25000 psi (1723 bar)
.021 cu in (.34 ml)
MS
.83 cu in (13.6 ml)
*Note: 29723 series rated to 10,000 psi (690 bar) maximum (ratios -110 and -188)
Key Features
• Choice of 6 models, 9 ratios,
27 possible combinations
• Flows to 2 gpm (7.5 l/min)
• Choice of wetted materials
• Single air head
• Pressures to 25,000 psi
(1724 bar)
• All Hydraulic fluids, water
(plain or DI), solvents, mild
chemicals, liquefied gases
• Drive pressure 25 to
125 psi (1.8 to 9 bar)
Optional Modifications
8
Number
Description
-HP
Hand pump attachment (with handle). Provides manual operation of pump for
precision pressure control or use without air power
26220-2
Hand pump attachment kit.
29002
Viton air drive.
51331
EPR seals for liquid section for 29723-XX ratio pumps.
51788
Piped exhaust – standard. Provides connection ports for drive and pilot exhausts.
Enables under tank top mounting and/or natural gas drive.
51794
Piped exhaust – sour gas. With hand pump (HP).
51794-2
Piped exhaust – sour gas. Without hand pump (HP).
53175
Level II cleaning.
53304
High pressure outlet port. Fits ¼” O.D. high pressure threaded and coned tube.
53935
Low temperature drive. Enables operation down to 5°F. Some sacrifice of seal life at
normal temperature. M or MS series.
57905
No return spring. Provides improved fill on suction stroke pumping liquefied gases
by utilizing the inlet pressure. Only available on M and MS series.
59888
Cycle timer installed.
80103
82367
Noise reduction kit fitted.
SS trim for 1⁄3 hp drive
www.haskel.com
For service codes, see page 17.
For weights and dimensions, see page 18.
.75 hp (.56 kW) Pump Models
Maximum Working Pressure
Model
Nominal
Ratio
4B
-14
1500 psi (103 bar)
.9 cu in (14.8 ml)
-30
3200 psi (221 bar)
.43 cu in (7.1 ml)
-37
3800 psi (262 bar)
.35 cu in (5.7 ml)
-55
6000 psi (414 bar)
.22 cu in (3.6 mil)
-100
10600 psi (731 bar)
.13 cu in (2.1 ml)
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
Displacement
per Cycle
For service codes, see page 17.
For weights and dimensions, see page 18.
Key Features
• One model available
in 5 ratios
• Choice of wetted materials
• Output pressures to
10,000 psi (690 bar)
• Drive pressure 3 psi to
100 psi (.2 to 7 bar)
• Single air head
• Flows to 1.5 gpm (5.7 l/min)
Optional Modifications
Number
Description
57639
Low drive air pressure. Allows user to regulate drive air to as low as 3 psi (.2 bar).
59354
Noise reduction kit fitted.
81575
Changes the “F” seal to a “W” seal. Recommend for use with water.
82104
Viton air drive.
www.haskel.com
9
1.5 hp (1.12 kW) Pump Models
Maximum Working Pressure
Model
Nominal
Ratio
DSTV(1)
-1.5
160 psi (11 bar)
31.9 cu in (513.0 ml)
ATV,
-4
1200 psi (83 bar)
20.0 cu in (328.0 ml)
AW, ASF,
-B10
1600 psi (110 bar)
4 cu in (66.4 ml)
DSF, DSTV
-B15
2400 psi (165 bar)
2.7 cu in (44.3 ml)
-25
4000 psi (276 bar)
1.6 cu in (26.6 ml)
-35
5700 psi (393 bar)
1.2 cu in (19 ml)
-60
9800 psi (676 bar)
.7 cu in (11 ml)
ATV
-8
850 psi (59 bar)
20 cu in (328.0 ml)
AW, ASF,
-100
16500 psi (1138 bar)
.4 cu in (6.7 ml)
DSF,
-150
20000 psi (1375 bar)
.28 cu in (4.5 ml)
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
Displacement
per Cycle
DTV(1) (2)
DTN(1)
Key Features
• Choice of 10 models,
13 ratios, 50 possible
combinations
• Output pressures to
50,000 psi (3448 bar)
• Choice of wetted materials
• Single air head
• Drive pressure 3 to 150 ps
(.2 to 10 bar)
• Flows to 22 gpm (83.0 l/min)
DSTV
HF, HSF,
-151
25000 psi (1724 bar)
.28 cu in (4.5 ml)
DSHF
-225
37000 psi (2551 bar)
.18 cu in (3.0 ml)
-300
50000 psi (3448 bar)
.14 cu in (2.3 ml)
-450
45000 psi (3403 bar)
.09 cu in (1.5 ml)
HF
Optional Modifications
10
Number
Description
16821
Low air pressure control feature. For operating at air pressures as low as 3 to 4 psi
(.2 to .3 bar). Includes 28881 modification. 45 psi minimum pilot air required.
16831
Low temperature modification. For special sealing in air drive for operating
temperatures from as low as -20°F up to normal +120°F.
16834
Exhaust adapter. With back pressure balance piston.
27964
Interconnecting inlet-outlet tubing. ½” female for 4:1 ratio series pumps
(ATV-4 or DTV-4).
28000
Threaded vent (or purge) ports on standard distance piece. Except 1.5:1 ratio.
28881
Air pilot modification. 1⁄8” NPT. Allows remote start/stop of pump.
29376
Three-way cycling spool. For 1.5 hp and 2 hp single acting pumps, for use with CO2
29702
Single stroke modification.
51050
Extreme service cycling modification. Not recommended for long stall periods.
51056
Exhaust/pilot vent combination.
51331
EPR (Ethylene propylene) static seals in wetted section. Applies to distance piece
pumps only.
51345
Sour gas drive provision to N.A.C.E. specifications. 1.5 hp to 2.2 hp distance piece
pumps only, single air head and double air head.
52788
Viton seals air drive.
53925
Severe Arctic low temperature service. -25, -35, -60, -100, -150, -151, -225, -300, -450
ratios.
54885
Rotate pump body 90° from standard.
54935
SS trim for 5/3 air drive.
55516
Polyurethane (“W”) seal. For F or TV series pumps, except high output models.
59353
Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD.
82460
HNBR seals in air drive section.
www.haskel.com
(1) These series are “Lift” pumps and maximum outlet
pressure is (air drive x pump ratio) + inlet pressure
(2) DTV has poppet checks
For service codes, see page 17.
For weights and dimensions, see page 20.
1.5 hp (1.12 kW) High Output
Flow Pumps
Available in a choice of 4 models, these high output, low
ratio pumps are capable of pressures to 1200 psi (82 bar) and
flow rates of up to 22 gpm (83 l/min). These are “lift” pumps
whereby the outlet pressure equals the air drive x the pump
ratio plus the inlet pressure.
Mounting Brackets
All series mounting brackets have 7/16” holes (slots) for 3/8”
bolts. Upper mounting brackets are not furnished as standard
on single air head non-distance piece units.
Dimensional Data
Mounting Brackets
Model DSTV-1.5 has a maximum air drive of 150 psi (10 bar)
and is capable of pressures up to 160 psi (11 bar). The model
ATV, DTN-4 and DTV-4 work on a maximum air drive of 150 psi
(10 bar) and have a maximum intermittent pressure rating of
1200 psi (83 bar). A noise reduction modification is available
for applications where noise level is an issue.
Distance Piece (Separation)
Pumps with prefix “D” in the model number have aluminum
distance piece between the air drive and pump section
(except DSTV-1.5).
www.haskel.com
11
2 & 2.2 hp (1.49 & 1.64 kW) Pump Models
Model
2 hp
AW, ASF,
DSF, DSTV
• Output pressures to
100000 psi (7000 bar)
• Double and triple air heads
• Drive pressure 3 to
100 psi (.2 to 7 bar)
3 hp (2.24 kW) Pump Models
• Output pressures to
33000 psi (2275 bar)
• Flow rates to 8 gpm (30 l/min)
12
www.haskel.com
-B22
3200 psi (221 bar)
4 cu in (66.4 ml)
-B32
4800 psi (331 bar)
2.7 cu in (44.3 ml)
-52
8000 psi (552 bar)
1.6 cu in (26.6 ml)
-72
11000 psi (758 bar)
1.2 cu in (19 ml)
-122
19000 psi (1310 bar)
.7 cu in (11 ml)
Displacement
per Cycle
-202
33000 psi (2275 bar)
.4 cu in (6.7 ml)
DSHF
-302
50000 psi (3448 bar)
.28 cu in (4.5 ml)
DSXHF
-452
70000 psi (4827 bar)
.18 cu in (3.0 ml)
-602
75000 psi (5171 bar)
.14 cu in (2.3 ml)
-683
70000 psi (4827 bar)
.18 cu in (3.0 ml)
-903
75000 psi (5171 bar)
.14 cu in (2.3 ml)
DSXHW
-1373
100000 psi (6895 bar)
.09 cu in (1.4 ml)
AFD, DSFD,
-B60
6500 psi (448 bar)
1.3 cu in (22 ml)
• Choice of wetted materials
When using high pressure ratio pumps the reliability of the XH models
(-452 through -1373) will be improved with an air driven supercharge
pump, not only to simplify priming but to reduce fatigue stresses. The
higher the supercharge, the better the results. Also install a relief valve
to protect the lower pressure pump from potential back pressure.
Supercharging of the -1373 model is recommended. This approach will
ensure a reasonable life for the seals and other wear components.
Key Features
• One model available
in 8 ratios
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
HF, HSF,
DSXHF
• Flows to 5 gpm (15 l/min)
2.2 hp
Key Features
• Choice of 16 models,
13 ratios, 46 possible
combinations
Maximum Working Pressure
Nominal
Ratio
DFD, ASFD
For service codes, see page 17.
For weights and dimensions, see page 20.
For service
service codes,
codes, see
see page
page 17.
17.
For
For
For weights
weights and
and dimensions,
dimensions, see
see page
page 20.
20.
Maximum Working Pressure
Model
Nominal
Ratio
ASFD
10
1600 psi (110 bar)
8.1 cu in (132.8 ml)
15
2400 psi (165 bar)
5.4 cu in (88.6 ml)
25
4000 psi (276 bar)
3.3 cu in (53.2 ml)
35
5700 psi (393 bar)
2.3 cu in (38 ml)
60
9800 psi (676 bar)
1.3 cu in (22 ml)
100
16500 psi (1138 bar)
.8 cu in (13.4 ml)
150
20000 psi (1379 bar)
.6 cu in (9 ml)
202
33000 psi (2275 bar)
.8 cu in (13.4 ml)
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
For service codes, see page 17.
For weights and dimensions, see page 21.
• Single air head
• Drive pressure 3 to 150 psi
(.2 to 10 bar)
Displacement
per Cycle
Optional Modifications (for 2 hp, 2.2 hp and 3 hp pump models)
Number
Description
16821
Assures reliable drive operation with pressures low as 3 psi as long as 20 psi or
more is provided to the separate 1⁄8” NPT port.
55516
Polyurethane (“W”) seal. For F or TV series pumps, except high output models.
59353
Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD.
Low temperature modification. For special sealing in air drive for operating
temperatures from as low as -20°F up to normal +120°F.
55465
Ceramic Plunger -60 Ratio.
55516
Polyurethane “W” seal in “F” series pumps-except high output models.
16834
Exhaust adapter. With back pressure balance piston.
59353
Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD.
29376
Three-way cycling spool. For 1.5 hp and 2 hp single acting pumps.
59888
Cycle timer installed.
82460
HNBR Seals in air drive section.
16831
51050
Extreme service cycling modification. Not recommended for long stall periods.
51056
Exhaust/pilot vent combination.
51331
EPR (Ethylene propylene) static seals in wetted section. Applies to distance piece
pumps only.
51345
Sour gas drive provision to N.A.C.E. specifications. 1.5 hp to 2.2 hp distance
piece pumps only, single air head and double air head.
52788
Viton seals. Air drive only – 1.5 hp to 2.2 hp pumps only.
53925-4
Severe Arctic low temperature service. -10, -15, -22, -32
54885
Rotate pump body 90° from standard. Except 3 hp pump.
54935
SS trim for 5/3 air drive.
www.haskel.com
13
6 hp (4.47 kW) Pump Models
Maximum Working Pressure
Model
Nominal
Ratio
GWD,
-12
4000 psi (276 bar)
15.9 cu in (260 ml)
GW, GSF,
-35
4375 psi (302 bar)
6.0 cu in (98 ml)
DGSF,
-60
7500 psi (517 bar)
3.5 cu in (57 ml)
DGSTV
-100
10000 psi (690 bar)
2.1 cu in (34.5 ml)
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
Displacement
per Cycle
GSFD,
DGSFD(1),
DGSTVD(1)
(1) Double Acting “Lift” Pumps
Key Features
• Choice of 10 models, 4 ratios,
20 possible combinations
• Single air head –
double acting
• Output pressures to
10,000 psi (690 bar)
• Drive pressure 3 to
125 psi (.2 to 9 bar)
• Flow rates to 21 gpm (80 l/min) • All hydraulic fluids, water
(plain or DI), solvents
• Choice of wetted materials
8 hp (5.97 kW) Pump Models
For service codes, see page 17.
For weights and dimensions, see page 22.
Incorporating 10 models, this heavy duty range of double
acting pumps provide pressures up to 10,000 psi (690 bar)
and flow rates up to 4 gpm (15 l/min).
Designed to operate with air drive pressures between 40 and
125 psi (2.8 and 9 bar). For drive pressures 3 to 40 psi (.2 to
2.8 bar), order 51875-1 mod.
Maximum Working Pressure
Model
Nominal
Ratio
8SFD,
-25(1)
4000 psi (276 bar)
14 cu in (229 ml)
-40
6000 psi (408 bar)
9 cu in (145.3 ml)
-65
10000 psi (690 bar)
5.4 cu in (88.2 ml)
8DSFD
-100(1)
10000 psi (690 bar)
3.5 cu in (57.5 ml)
8SFD2 (1)
-55
7200 psi (496 bar)
14 cu in (229 ml)
-88
10000 psi (786 bar)
8.83 cu in (144 ml)
-224
29000 psi (1724 bar)
3.5 cu in (57 ml)
-225(1)
25000 psi (1724 bar)
1.6 cu in (25.5 ml)
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
Displacement
per Cycle
8DSFD,
8DSTVD
8FD
8SFD
Key Features
• Choice of 9 models, 8 ratios,
9 possible combinations
• Pressures to 30,000 psi
(2068 bar)
• Flow rates to 11.5 gpm
(44 l/min)
14
www.haskel.com
• All hydraulic fluids, water
(plain or DI), solvents,
liquefied gases
• Choice of wetted materials
8HSFD
(1) Double Acting “Lift” Pumps
• Single air head – double acting
• Drive pressure 3 to 125 psi
(.2 to 9 bar)
For service codes, see page 17.
For weights and dimensions, see page 21.
10 hp (7.46 kW) Pump Models
Maximum Working Pressure
Model
Nominal
Ratio
D14STD
125(1)
16000 psi (1103 bar)
8.8 cu in (144.2 ml)
315(1)
36000 psi (2482 bar)
3.5 cu in (57.4 ml)
125(1)
16000 psi (1103 bar)
8.8 cu in (144.2 ml)
315(1)
36000 psi (2482 bar)
3.5 cu in (57.4 ml)
D14SFD
Displacement
per Cycle
Consult chart on page 6 for more information
regarding continuous/intermittent pressures.
(1) Double Acting “Lift” Pumps
For service codes, see page 17.
For weights and dimensions, see page 21.
Key Features
• Choice of 4 models, 4 ratios, 4 possible combinations
• Pressures to 36000 psi (2500 bar)
• Flow rates to 3 gpm (11 l/min)
• Drive pressure 3 to 125 psi (.2 to 9 bar)
• All hydraulic fluids, water (plain or DI), solvents, liquefied gases
• Choice of wetted materials
Optional Modifications (for 6 hp, 8 hp and 10 hp pump)
Number
Description
29125
External pilot modification – for 6 hp thru 10 hp pumps.
87410
Low air pressure control – for 6 hp thru 10 hp pumps.
54030
Sour gas air drive provision to NACE spec. 6 hp distance piece pumps only.
54936
Exhaust/pilot vent combiner.
57002
Viton seals – air drive only – 6 hp
57944
Viton seals – air drive only – 8 hp
59888
Cycle timer installed.
Incorporating two basic models, this
heavy duty range of double acting pumps
provide pressures up to 36000 psi
(2482 bar) and output flow rate up to
3 gpm (11 l/min).
Operating from a maximum air drive
pressure of 125 psi (9 bar), these pumps
are designed for medium to high pressure
service with minimum maintenance.
These large, slow speed pumps approach
a seal life as high as 5 times that of
many smaller pumps and this advantage
becomes ever greater in heavy duty
service involving water, or other liquids
with negligible lubricity.
www.haskel.com
15
Power System Specialists
World safety standards and quality demands are rising.
Component manufacturers are required to provide test
certification and product quality assurance which can only be
determined using the types of systems which Haskel can provide.
Typically, we have built systems for production and field testing
the proof, leak, and burst aspects of hoses, cylinders, and valves.
These systems can be portable, mobile, or static test rigs. We
also offer a range of standard pressure packs used for power
jacking, clamping, and other applications where reliable power
is needed.
Quality and
After-Sale Service
Haskel meets the requirements of
international quality assurance ISO 9001.
Build quality is matched by an innovative
design and problem solving ability which stems from years of
years of experience. Our representatives around the world are
carefully chosen and trained to help you arrive at a correct
product choice, and to offer a maintenance and parts service
that is second to none.
Selecting Your Accessories
Haskel can either provide accessories separately or supply them fitted to form a complete
package suited to your application. Additionally, Haskel can customer nominated
accessories. Our accessories catalog is available and our technical support team is always
ready to advise you on the most suitable choice of accessories for your application.
•
•
•
•
•
16
Air pilot switches
Air pilot valves
Regulating relief valves
Directional control and release valves
Hydraulic accumulators, gas receivers
and storage cylinders
www.haskel.com
• High pressure valves, fittings and
tubing
• Plenum chambers
• Port adapters
• Gauge snubbers
• Filters
• Stainless steel check valves
Intensifiers with integral checks for
cycling
• Capillary type gauge snubbers
Please ask for your copy of our latest
accessories brochure.
Liquids Compatible with
Haskel Pumps
To assist in easier pump selection, we have classified various
popular liquids in groups and assigned to each group a service
code. These service code numbers are featured in the chart to
the right and are designated for each pump series. Seals and
other wetted materials can be supplied to suit your preferred
liquid. For advice, please contact our technical services
personnel at 818-843-4000.
Services
hp
Model
M
.33
MS
MDSTV
29723
.75
4B -14 to -37
4B -55 to -100
5 Skydrol and Aerosafe hydraulic
acetone and some
alcohols (ethyl, methyl, and isopropyl).
5A. Also suitable for these
if Viton static seals are
replaced with EPR; specify
number 51331 (no
extra charge); e.g., 51331-MDTV-5. Most phosphate esterbased
solidify at approximately 30000 psi.
6 Deionized water; demineralized water.
Note: Dynamic seal life with non-lubricating fluids will
understandably be less than with lubricating types.
Drive Section
-4° (25°F) to +65°C (150°F) (low temperature seals are available
for Arctic operation).
•
•
•
•
•
•
•
•
•
HSF
DSHF
DSTV
Liquid Section
For reasonable seal life, high temperature should be limited
to 54° C (130° F), for F and W seal models, 135° C (275° F) for T
and TV models (with distance piece).
ATV
DTV
DSTV-1.5
AFD
DFD
ASFD
DSFD
DSXHF
GSF
DGSF
DGSTV
GWD
GSFD
DGFD
DGSFD
DGSTVD
8FD
8SFD
8
8SFD2
8DSFD
8DSTVD
8HSFD
D14STD-125
10
•
•
GW
HF
Operating Temperatures
•
•
•
DSF
6
•
•
•
ASFD
Service Codes
1 Petroleum-based oils, kerosene, ethylene glycol,
water with 5% soluble oil.
2 Plain water, diesel fuel.
3 Most phosphate ester-based
hydraulic
e.g. Pydraul, Lindol, Cellulube, Fyrquel, and Houghtosafe
1120 and petroleum-based solvents compatible with
UHMWPE (Ultra-high Molecular Weight Polyethylene)
dynamic seals and Viton static seals.
4 Petroleum-based solvents, e.g. aromatic hydrocarbons
(benzene, toluene, xylene, hylene, etc.); chlorinated solvents
(trichlorethylene, carbon tetrachloride, chlorobenzine, etc.);
solvents
mercaptans, Dowtherm A,
etc.); Dowtherm E,
plus all of Group 3 and some mildly corrosive acids compatible
with wetted materials. See note 5A for service with methylethyl-ketone, methyl acetone, diacetone, alcohol and freon 22.
ASF
D14STD-315
D14SFD-125
D14SFD-315
3
•
•
•
•
DSXHW
AW
3
2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Services
1.5
2
2.2
1
•
•
•
•
•
•
•
•
•
•
•
•
•
4
•
•
5
•
6
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
www.haskel.com
17
NB. Plan view of
M-Pump is common to
all M-Series pumps.
Net weight 2.65 kg
Boxed weight 2.9 kg
Box size 23 x 18 x 12 cm
11.91 mm
(.075”)
Weights and
Dimensions
206 mm
(8”)
.33 hp (.25 kW) M Series Pump Models
Net weight 4 kg
Boxed weight 4.25 kg
Box size 23 x 18 x 12 cm
M-7, M-12
approx. weight 9 lbs (4 kg)
MS-7, MS-12
approx. weight
9 lbs (4 kg)
Net weight 6 kg
Boxed weight 6.5 kg
Box size 30 x 20 x 15 cm
Net weight 2.5 kg
Boxed weight 2.75 kg
Box size 23 x 18 x 12 cm
MS-21, MS-36, MS-71,
MS-110, MS-188, approx.
weight 6 lbs (2.7 kg)
18
www.haskel.com
M-21, M-36, M-71, M-110,
M-188 approx. weight 6 lbs
(2.7 kg)
MS-220 approx. weight
6 lbs (2.7 kg)
M-5 approx. weight 9 lbs (4 kg)
29723-21, 29723-36, 29723-71, 29723-110
approx. weight 6.5 lbs (3 kg)
MDSTV-5 , MDTV
Approx weight 15 1/2 lbs (7 kg)
.75 hp (.56 kW) Pump Models
Model 4B-14, and
4B-30
4B-21,
4B-25
and 4B-30
Model 4B-55 and
4B-75
www.haskel.com
19
KS
KS N: 3XPS0RGHOV
DSFD-B60
iÌÊÜiˆ} ÌÊ£nʎ}
œÝi`ÊÜiˆ} ÌÊÓäʎ}
œÝÊÈâiÊÈnÊÝÊ{ÓÊÝÊxäÊV“
iÌÊÜiˆ} ÌÊ£äʎ}
œÝi`ÊÜiˆ} ÌÊ££ÊŽ}
œÝÊÈâiÊÎÇÊÝÊÎÇÊÝÊÎnÊV“
25.4 mm = 1 inch
2 hp high ratio pumps;
-683 and -903 ratios
1.5 and 2 hp low ratio pumps;
-B10 and -B15 ratios
iÌÊÜiˆ} ÌÊ£{ʎ}
œÝi`ÊÜiˆ} ÌÊ£xʎ}
œÝÊÈâiÊxÓÊÝÊ{äÊÝÊ{äÊV“
(-52, -72, +22)
⁄4 HP port (-202, -302)
1
1.5 and 2 hp medium ratio pumps;
-52, -72, -122, -202 and -302 ratios
20
www.haskel.com
2 hp (1.49 & 1.64 kW) Pump Models;
-1373 ratio
KS
(N. :
3W
XP
F lRsQ (W c
ont.)
. 7 5 hp
5 6 k
) S
P u0mRpG HMO V
o d e
Model 4B-37
approx. weight 10 lbs (4.5 kg)
Model 4B-100
4B-100 & 4B-150
approx. weight
approx.
weight11
11lbs
lbs(5(5kg)
kg)
1.5 hp, 2&2.2 hp (1.12, 1.49 & 1.64 kW)Pump Models
DSFD-B60
www.haskel.com
21
1.5 hp, 2&2.2 hp (1.12, 1.49 & 1.64 kW)Pump Models (cont.)
iÌÊÜiˆ} ÌÊ£nʎ}
œÝi`ÊÜiˆ} ÌÊÓäʎ}
œÝÊÈâiÊÈnÊÝÊ{ÓÊÝÊxäÊV“
iÌÊÜiˆ} ÌÊ£äʎ}
œÝi`ÊÜiˆ} ÌÊ££ÊŽ}
œÝÊÈâiÊÎÇÊÝÊÎÇÊÝÊÎnÊV“
1.5 and 2 hp low ratio pumps;
-B10 and -B15 ratios
iÌÊÜiˆ} ÌÊ£{ʎ}
œÝi`ÊÜiˆ} ÌÊ£xʎ}
œÝÊÈâiÊxÓÊÝÊ{äÊÝÊ{äÊV“
25.4 mm = 1 inch
2 hp high ratio pumps;
-683 and -903 ratios
⁄2” NPT (-52, -72, 122)
Liquid Outlet
1
⁄4 HP port (-202, -302)
1
394 mm
­£xÊ£ÉÓ»®
Breathers
ir Drive Inlet
1ÉÓ»Ê *T
1.5 and 2 hp medium ratio pumps;
-52, -72, -122, -202 and -302 ratios
ˆquid Inlet
£ÉÓ»Ê *T
ˆÀÊ Ý aust
1ÉÓ»Ê *T
241 mm
­™Ê£ÉÓ»®
iÌÊÜiˆ} ÌÊ£äʎ}
œÝi`ÊÜiˆ} ÌÊ££ÊŽ}
œÝÊÈâiÊ{xÊÝÊÎÇÊÝÊ{{ÊV“
2 hp (1.49 & 1.64 kW) pump models;
-1373 ratio
iÌÊÜiˆ} ÌÊ£nʎ}
œÝi`ÊÜiˆ} ÌÊ£™ÊŽ}
œÝÊÈâiÊ{xÊÝÊÎÇÊÝÊ{{ÊV“
ATV-4 pumps; double acting, high output
œÌi\ʜÀʓœ`iÊ /6-4, add distance piece dimension from page 11.
Interconnecting inlet and outlet port tubing shown.
22
www.haskel.com
DSTV-1.5 pump; single
acting, high output
ˆquid Outlet
3É{»Ê*Ê*œÀt
24x mm
­™ÊxÉn»®
iÌÊÜiˆ} Ìʙ°xʎ}
œÝi`ÊÜiˆ} ÌÊ£äʎ}
œÝÊÈâiÊÓxÊÝÊÓÈÊÝÊÓÓÊV“
11 mm
(7/16”) (TYP)
(9 7/8”)
119 mm
(4 11/16”)
Mounting
Bracket
(2 places)
76 mm
(3”)
Handle
⁄2” NPT
Liquid
Outlet*
1
279 mm
(11”)
413 mm
(15 1/4”)
Air Drive
Exhaust Port
1/2” NPT
64 mm
(2 1/2”)
Air Drive Inlet Port
1/2” NPT
154 mm
17 mm (6 1/16”)
(11/16”)
1.5 and 2 hp medium and high ratios; -25
through -150, -151*, -225*, -300* and -450* ratios
*1⁄4” Super Pressure Outlet Port
Hydraulic Outlet Port
1/2” NPT
(2 places, this side)
144 mm
(5 11/16”)
105 mm
(4 5/32”) (TYP)
Hydraulic Inlet Port
1/2” NPT
(2 places, this side)
102 mm
(4”)
209 mm
(8 1/4”)
ATV-8 pumps
AFD or ASFD, -B60, -B100 pumps;
double acting, high output
3 hp (2.24 kW) Pump Models
AIR DRIVE INLET PORT
1/2” NPT
MODEL
ASFD-15
OUTLET PORT
1/2” NPT
OUTLET PORT
INLET PORT
ASFD-25
ASFD-25ASFD-35,
ASFD-35ASFD-60
1/2” NPT
ASFD-100 3⁄8" med.
ASFD-60ASFD-150 pressure
1/2” NPT
}
ASFD-100
OUTLET PORT
1/2” NPT
ASFD-150
3/8” MEDIUM
PRESSURE
9/16-18 THREAD
ASFD-10
ASFD-202
OUTLET PORT
1/2” NPT
www
www.haskel.com
23
KS N: 3XPS0RGHOV
iÌÊÜiˆ} ÌÊΣʏLÃÊ­£{ʎ}®
œÝi`ÊÜiˆ} ÌÊÎxʏLÃÊ­£Èʎ}®
œÝÊÈâiÊxÓÊÝÊΙÊÝÊΙÊV“
Ê“œ`iÃÊ >ÛiÊÓʜvvÊ11⁄4”
*/Ê>ˆÀÊiÝ >ÕÃÌÊ«œÀÌÃÊ
and 1 off 3⁄4»Ê */Ê>ˆÀÊ`ÀˆÛiÊ
inlet ports.
Models GW, GSF nominal ratio 35, 60 100:1
iÌÊÜiˆ} ÌÊ{£ÊLÃÊ­£n°xʎ}®
œÝi`ÊÜiˆ} ÌÊ{nÊ­ÓÓʎ}®
œÝÊÈâiÊÈÈÊÝÊ{£ÊÝÊ{™ÊV“
DGSTV
nominal
ratio 35,
60 100:1
Models DGSF,
DGF, DGSF,
DGSTV
nominal
ratio
35, 60 100:1
iÌÊÜiˆ} ÌÊxÇʏLÃÊ­ÓÈʎ}®
œÝi`ÊÜiˆ} ÌÊȣʭÓÇʎ}®
œÝÊÈâiÊÈÈÊÝÊ{£ÊÝÊ{™ÊV“
If interconnecting piping for the two
inlets and two outlets is required, specify
modifiV>̈œ˜ÊәäÇÇÊÜˆÌ ÊޜÕÀʜÀ`ir.
Models GWD, GSFD nominal ratio 12:1
iÌÊÜiˆ} ÌÊÈÈʏLÃÊ­Îäʎ}®
œÝi`ÊÜiˆ} ÌÊÇxʏLÃÊ­Î{ʎ}®
œÝÊÈâiʙ£ÊÝÊx£ÊÝÊΙÊV“
If interconnecting piping for the two inlets and two outlets
is required, specify modifiV>̈œ˜ÊәäÇnÊÜˆÌ ÊޜÕÀʜÀ`ir.
Models DGSFD,
DGFD, DGSFD,
nominal
DGSTV DGSTVD
nominal ratio
12:1 ratio 12:1
24
www.haskel.com
8 hp (5.97 kW) Pump Models
9.65
[245 mm]
27.66
[703 mm]
5.21
[132 mm]
AIR DRIVE INLET
PORT 3/4" NPT
(130 PSIG MAX)
22.93
[582 mm]
CYCLING SPOOL ACCESS
2X LIQUID INLET PORT
3/8" HIGH PRESSURE
(25,000 PSIG MAX)
10.96
[278 mm]
10.17
[258 mm]
2X AIR DRIVE/SEAL SECTION
VENT PORT 1/4" NPT
4.88
[124 mm]
2X LIQUID OUTLET PORT
3/8" HIGH PRESSURE
(25,000 PSIG MAX)
7.00
[178 mm]
8.25
[210 mm]
5.78
[147 mm]
11.36
[288 mm]
4X MOUNTING HOLES
n 9/16"
Model
Models8HSFD-25
8HSFD-25, 8FD-25, 8SFD-25
Inlet,Outlet
Outletports
ports3/8”
3/8’’HP
HP
Inlet,
Models 8DSFD-25 & 8DSTVD-25
Model 8SFD-40
Model 8SFD-65
www.haskel.com
25
KS N: 3XPS0RGHOV FRQW
8X .53 in [13 mm]
(MOUNTING HOLES
32.73 in [831 mm]
9.65 in [245 mm]
AIR DRIVE INLET
3/4 NPT
2X HYDRAULIC OUTLET
1" NPT PORT
11.10 in [282 mm]
10.17 in [258 mm]
4.88 in [124 mm]
2X HYDRAULIC INLET
1 1/4" NPT PORT
4.25 in [108 mm]
18.11 in [460 mm]
7.00 in [178 mm]
19.55 in [496 mm]
8.25 in [210 mm]
26.48 in [673 mm]
29.92 in [760 mm]
Model 8SFD2-55
8X .53 in [13 mm]
(MOUNTING HOLES)
9.65 in [245 mm]
33.80 in [858 mm]
AIR DRIVE LET
3/4 NPT
2X HYDRAULIC OUTLET
1" NPT PORT
11.10 in [282
10.17 in [258 mm]
4.88 in [124 mm]
2X HYDRAULIC INLET
1 1/4" NPT PORT
18.11 in [460 mm]
19.55 in [496 mm]
28.62 in [727 mm]
32.06 in [814 mm]
Model 8SFD2-88
26
www.haskel.com
4.25 in [108 mm]
7.00 in [178 mm]
8.25 in [210 mm]
HYDRAULIC OUTLET
3/8 HP PORT
(MAWP: 29,000 PSI)
HYDRAULIC INTLET
1/2 NPT PORT
(MAWP: 10,000 PSI)
HYDRAULIC OUTLET
3/8 HP PORT
(MAWP: 29,000 PSI)
HYDRAULIC INLET
1/2 NPT PORT
(MAWP: 10,000 PSI)
8X .53 in [13 mm]
(MOUNTING HOLES)
9.65 in [245 mm]
AIR DRIVE INLET
3/4 NPT
11.10 in [282 mm]
10.17 in [258 mm]
4.88 in [124 mm]
18.11 in [460 mm]
4.25 in [108 mm]
19.55 in [496 mm]
7.00 in [178 mm]
35.78 in [909 mm]
37.78 in [960 mm]
8.25 in [210 mm]
Model 8SFD2-224
10 hp (7.46 kW) Pump Models
Model D14STD-125
Model D14STD-315
www.haskel.com
27
For more information on our high-pressure products,
visit Haskel.com or contact your local Haskel representative.
Haskel is a brand of Accudyne Industries, a leading global provider of
precision-engineered, process-critical and technologically advanced
flow control systems and industrial compressors that deliver
consistently high performance and give confidence to the mission
of our customers in the most important industries and harshest
environments around the world. The company is powered by more
than 3,000 employees at 18 manufacturing facilities, supporting a
broad range of industries in more than 150 countries.
haskel.com
l.co
com
om
m
[email protected]
sales@haskel
skel
kel.c
l.co
com