Pressure on Demand Pneumatic Driven Liquid Pumps LP-GL 04/17 High Pressure Haskel pneumatic driven liquid pumps are designed to provide a safe, reliable and economical, source of hydraulic pressure. This brochure introduces our pneumatic driven liquid pump range. Visit our website at www.haskel.com for more information or to locate a distributor. Why Use Haskel Pneumatic Driven Pumps? Our pumps offer many advantages over electrically driven pumps: • • • • • • • • Safe pneumatic operation – no heat, flame or spark risk Up to 100,000 psi (7000 bar) capability Infinitely variable cycling speed Stall feature at pre-determined pressure to hold that pressure without consuming power Problem-free stop/start applications Easily automated – many modification and control options Suitable for most liquids and liquefied gases Alternative gas drive options – sour gas, natural gas, boil off gases, nitrogen Applications include: • • • • • • • • • Pressure testing Work holding/power clamping Jacking/lifting Valve actuator control Hydraulic cylinder actuation Press safety overload devices Roller tensioning Metering Precision lubrication and spraying • Liquefied gas transfer 2 www.haskel.com • No need for air line lubrication – saves costs and prevents contamination • Robust, reliable, compact and easy to maintain proven design • Unbalanced cycling spool provides immediate response to pressure changes • Also available in standard, or custom built power pac configurations • Excellent worldwide service for spares and repairs • ATEX approved • CE certified Pressure and Flow on Demand This guide will help you to pre-select the pump ideally suited for your application. If you have specific questions, however, we urge you to provide Haskel with the operational details of your application. We will recommend a model and any corresponding accessories. Output Horsepower Ratings The pumps are categorized on their horsepower ratings (see pages 6-7). These are approximate and peak at 100 psi (7 bar), assuming adequate drive, pressure and volume. Peak horsepower is at about 75% nominal ratio x drive pressure, i.e. 100:1 pump @ 100 psi air drive peaks at 100 x 100 = 10000 x 0.75 psi = 7500 psi (517 bar) hydraulic pressure. Double and Triple Air Head Pumps Performance can be extended for the 1.5 hp pumps by stacking air pistons without changing the hydraulic piston. Haskel multi-head pumps consume less air than competitive single head pumps of the same area, as only one head is pressurized on the return stroke; e.g., on a 1.5 hp pump additional heads can raise performance to 2 hp. Double air head pumps are identified by the last digit 2 in the pump model number. Thus, a nominal 50:1 ratio pump with two air heads is described as a 52. Similarly, a triple air head pump is identified with a last digit 3. Thus, a 900 ratio pump with three air heads is described as a 903. Single Drive Head Pump 25.9 sq in (167 sq cm) Operation The pumps automatically reciprocate on a differential piston principle. A large piston driven by relatively low pressure drive acts directly upon a smaller hydraulic piston. The nominal ratio between piston sizes is indicated in the model coding and approximates to the maximum working pressure. The actual ratio is about 15% above nominal so that the pump continues to cycle when drive pressure equals nominal ratio. Initially, the pump will cycle at maximum speed acting as a transfer pump to pressurize downstream. It will cycle at a slower rate as the fluid meets resistance until it stalls at maximum output pressure. When a pressure drop downstream occurs, it will recycle as necessary in an effort to maintain maximum pressure. Stall pressure is achieved when the outlet pressure rises and offers more resistance to the reciprocating differential piston assembly. The piston assembly then stalls when the forces balance, e.g. when drive pressure x drive piston area equals outlet (stall) pressure x driven hydraulic plunger area. The pump design is sensitive to very small pressure drops due to the low frictional resistance of the large diameter drive piston and hydraulic piston seals. 0.65 sq in (4 sq cm) Therefore, actual ratio = 40:1 Nominal Ratio = 35:1 Double Air Head Pump Area 25.9 sq in (167 sq cm) Area 25.2 sq in (163 sq cm) Area .65 sq in (4 sq cm) Therefore, actual ratio = 79:1 Nominal Ratio = 72:1* Triple Air Head Pump Area 25.9 sq in (167 sq cm) Area 25.2 sq in (163 sq cm) Area 25.2 sq in (163 sq cm) Area .65 sq in (4 sq cm) Therefore, actual ratio = 118:1 Nominal Ratio = 103:1** Nominal Ratio * (2) Indicates Double Drive Piston ** (3) Indicates Triple Drive Piston www.haskel.com 3 1. Drive Section 2. Hydraulic Check Valves Anatomy of a Pneumatic Driven Pump 1. Drive Section The piston, complete with “O” ring seal, operates in an epoxy filled, fiberglass wound barrel, the diameter of which is constant throughout a given series of pumps. Drive media forces the piston down on the compression stroke and raises it on the suction stroke (M series have a spring return). The piston is pre-lubricated during assembly and therefore no air line lubricator is necessary. 2. Hydraulic Section/Check Valves The drive piston is linked and connected to the hydraulic plunger/piston in the hydraulic section. Outlet flow and pressure are determined by the area of the hydraulic piston head, its nominal ratio with the drive piston head, and drive pressure. On the down stroke, liquid in the hydraulic section is forced under compression through the outlet check valve. Fresh liquid is induced via the inlet check valve on the return stroke. These check valves control the flow of liquid through the hydraulic section. They are spring-loaded and have a very low cracking pressure, allowing maximum opening on the induction stroke. The pressure of hydraulic fluid on the down stroke closes the inlet check valve and acts against the spring to open the outlet check valve. 3. Drive Cycling Valve This is a pilot-operated, unbalanced, lightweight spool, which directs drive pressure, first to the top of the drive piston, and then to the underside to reciprocate the piston (cycle). It actuates via pilot valves at the top and the bottom of the stroke, which causes the unbalanced spool to shift and reciprocate the piston. 3. Drive Cycling Valve 4. Hydraulic Seal 4 www.haskel.com 4. Hydraulic Seal/Check Valves This is one of the few wear parts. Its function is to allow the hydraulic piston to reciprocate without passing fluid into the drive section. The liquid, its pressure and its temperature determine seal specification. A distance piece can be incorporated between drive and hydraulic sections for complete contamination-free operation on most Haskel pumps. WETTED MATERIALS OF CONSTRUCTION AND SERVICES .33 hp MODEL M 1 MS 1, 2 29723 1.5 hp .75hp MDSTV 1, 2, 3, 5, 6 1, 2, 3, 4, 5, 6 NON METALLICS PUMP SECTION PLUNGERS Cad plated steel, Aluminum & SS 416 SS Urethane, PTFE, Buna All SS 316 SS UHMWPE, PTFE, Buna Separation - All SS Hard Chrome Plated 15.5PH SS + Dichronite UHMWPE, PTFE, Ryton Stainless Steel and Aluminum 303 Stainless Steel Viton, PTFE 4B-14 thru -37 1, 2 Aluminum Aluminum(Hard coated) UHWMPE, Buna 4B-55 thru -100 1, 2 303 SS 440 C. SS UHWMPE, Buna Nickel Plated Steel & SS 440C SS Urethane, Buna N, PTFE All SS 440C SS UHMWPE, Buna, PTFE, Ryton Separation - All SS 440OC SS Hard Chrome Plated UHMWPE, Viton, PTFE, Ryton Nickel Plated Steel & SS Stellite 15-5PH SS UHMWPE, Buna N All SS Stellite 15-5PH SS UHMWPE, Buna N Separation - All SS Stellite 15-5PH SS UHMWPE, Buna N Aluminum, Bronze & SS 15.5PH SS PTFE, Viton Separation - Aluminum, Bronze & SS 15.5PH SS PTFE, Viton 1, 2, 3, 4, 5, 6 Separation - All SS 17.4PH SS PTFE, Viton DSTV 1, 2, 3, 4, 5 Separation - All SS 440C SS Hard Chrome Plated PTFE, Viton DTN 1, 2, 5 Stainless Steel, Aluminum 300 Series SS Neopreen, PTFE AW 1 Nickel Plated Steel & SS 440C SS Urethane, Buna N, PTFE AFD 1 Nickel Plated Steel & SS 416 SS UHMWPE, Buna, PTFE, Ryton DFD 1, 3, 5 Nickel Plated Steel & SS 416 SS UHMWPE, Viton, PTFE, Rtyon ASFD 1, 2 All SS 15.5PH SS UHMWPE, Viton, PTFE, Rtyon ASF 1, 2 All SS 440C SS UHMWPE, Viton, PTFE, Rtyon AW 1 ASF 1, 2 DSF 1, 2, 3, 5, 6 HF 1 HSF 1, 2 DSHF 1, 2, 5, 6 ATV 1, 2 DTV 1, 2, 5 DSTV-1.5 2 thru 3hp WETTED MATERIALS SERVICES (refer to pg. 17) DSFD 1, 2, 3, 5, 6 Separation - All SS 15.5PH SS UHMWPE, Viton, PTFE, Rtyon DSF 1, 2, 3, 5, 6 Separation - All SS 440C SS Hard chrome plated UHMWPE, Viton, PTFE, Rtyon Nickel Plated Steel & SS Stellite 15-5PH SS* UHMWPE, Buna N All SS Stellite 15-5PH SS* UHMWPE, Buna N HF 1 HSF 1, 2 DSHF 1, 2, 5, 6 Separation - All SS Stellite 15-5PH SS* UHMWPE, Buna N DSXHF 1, 2, 5, 6 Separation - All SS Stellite 15-5PH SS UHMWPE, Buna N DSXHW 1, 2 Separation - All SS Stellite 15-5PH SS Urethane, PTFE DSTV-1.5 1, 2, 3, 4, 5, 6 Separation - All SS 17.4PH SS PTFE, Viton 1, 2, 3, 4, 5 Separation - All SS 440C SS Hard chrome plated PTFE, Viton Nickel Plated Steel, SS & Bronze Hard chrome plated 15.5PH SS Urethane, Buna N, PTFE All SS & Bronze Hard chrome plated 15.5PH SS UHMWPE, Viton, PTFE, Ryton DSTV 6 hp *Except -202 ratio is chrome plated 440 SS GW 1 GSF 1, 2 DGSF 1, 2, 3, 5, 6 Separation- All SS & Bronze Hard chrome plated 15.5PH SS UHMWPE, Viton, PTFE, Ryton DGSTV 1, 2, 3, 4, 5 Separation- All SS & Bronze Hard chrome plated 15.5PH SS Viton, PTFE, Ryton Nickel Plated Steel & SS 15.5PH SS Hard chrome plate optional Urethane, Buna N, PTFE All SS & Bronze 15.5PH SS Hard chrome plate optional UHMWPE, Buena N, PTFE, Ryton Separation- Nickel Plated Steel & SS 15.5PH SS hard chrome plate optional UHMWPE, Viton, PTFE, Ryton GWD 1 GSFD 1, 2 DGFD 1, 3, 5 DGSFD 1, 2, 3, 4, 5, 6 Separation- All SS & Bronze 15.5PH SS Hard chrome plate optional UHMWPE, Viton, PTFE, Ryton 1, 2, 3. 4, 5 Separation- All SS & Bronze 17.4PH SS Hard chrome plate optional PTFE, Viton DGSTVD 8 hp 8SFD All SS & Bronze* Hard chrome plated 15.5PH SS UHMWPE, Viton, PTFE, Ryton 1, 2 ,3 ,5, 6 Separation- All SS & Bronze 15.5PH SS Hard chrome UHMWPE, Viton, PTFE, Ryton 8DTVD 1, 2, 3, 4, 5, 6 Separation- All SS & Bronze 15.5PH SS Hard chrome PTFE, Viton 8HSFD 1, 2 All SS & Bronze* 17.4PH SS UHMWPE, Viton, PTFE, Ryton 1, 2, 3, 5, 6 All SS & Bronze* 15-5 PH SS Hard chrome Viton, PTFE 1, 2 ,6 All SS & Bronze* 15-5 PH SS Hard chrome PTFE, Viton, UHMWPE D14STD-125 1, 2, 3, 4, 5A All SS & Bronze Hard chrome plated 440C SS PTFE, Viton D14STD-315 1, 2, 3, 4, 5A All SS & Bronze Hard chrome plated 440C SS PTFE, Viton D14SFD-125 1, 2, 3, 5A, 6 All SS & Bronze Tungston Carbide Coated 15.5PH SS UHMWPE, Viton, PTFE, Ryton D14SFD-315 1, 2, 3, 5A 6 All SS & Bronze Tungston Carbide Coated 15.5PH SS UHMWPE, Viton, PTFE, Ryton 8DSTVD 8SFD2 10 hp 1, 2 8DSFD www.haskel.com 5 Power Air Head Max Air Performance and Specification Overview Maximum Rated Output Pressure Pump Model Code 0.33 hp Single Single 0.75 hp 125 psi/8.6 bar 100 psi/7 bar 1.5 hp Single 150 psi/10.5 bar cu in/min l/min -14 -30 -37 -55 -100 16 34 42 63 114 1500 3200 3800 6000 10600 103 221 262 414 731 1500 3200 3800 6000 10600 103 221 262 414 731 0.9 0.43 0.35 0.22 0.13 14.7 7.0 5.7 3.6 2.0 428 204 166 105 62 7.01 3.35 2.72 1.71 1.01 -1.5 -4 -B10 -B15 -25 -35 -60 -100 -150 -151 -225 -300 -450 1.6 4.6 11.5 17 29 40 69 115 173 173 260 345 533 240 690 1600 2400 4000 5700 9800 15000 15000 25000 30000 30000 45000 17 48 110 165 276 393 676 1034 1034 1724 2069 2069 3103 300 1200 1600 2400 4000 5700 9800 16500 20000 25000 37000 50000 45000 21 83 110 165 276 393 676 1138 1379 1724 2552 3448 3103 31.90 20.00 4.05 2.70 1.62 1.16 0.67 0.41 0.27 0.27 0.18 0.14 0.0 513 328 66.4 44.3 26.6 19.0 11.0 6.7 4.5 4.5 3.0 2.3 1.5 5104 3200 1215 810 486 348 201 123 81 81 41 32 20 83.6 52.4 19.9 13.3 8.0 5.7 3.3 2.0 1.3 1.3 0.7 0.5 0.3 -8 -B22 -B32 -52 -72 -122 -202 -302 -452 -602 9.2 23 34 57 80 138 230 346 520 690 850 3200 4800 5000 11000 15000 30000 30000 30000 30000 59 221 331 345 759 1034 2069 2069 2069 2069 1200 3200 4800 8000 11000 19000 33000 50000 70000 75000 83 221 331 552 759 1310 2276 3448 4828 5172 20 4.05 2.70 1.62 1.16 0.67 0.41 0.27 0.18 0.14 328 66.4 44.3 26.6 19.0 11.0 6.7 4.5 3.0 2.3 3200 1215 810 488 348 201 92 61 41 32 52.4 19.9 13.3 8.0 5.7 3.3 1.5 1.0 0.7 0.5 DSXHW -683 -903 -1373 780 1038 1575 30000 30000 30000 2069 2069 2069 70000 75000 100000 4828 5172 6897 0.18 0.14 0.086 3.0 2.3 1.4 25 20 12 0.41 0.33 0.197 AFD-DFD-ASFD-DSFD -B60 69 6500 448 6500 448 1.34 2.2 369 6.0 ASFD -10 -15 -25 -35 -60 -100 -150 -202 11.5 17 29 40 69 115 173 230 1600 2400 4000 5700 9800 15000 15000 30000 110 165 276 393 676 1034 1034 2069 1600 2400 4000 5700 9800 16500 20000 33000 110 165 276 393 676 1138 1379 2276 8.10 5.40 3.24 2.32 1.34 0.82 0.54 0.82 133 89 53.6 38.0 22.0 13.4 9.0 13.4 1823 1215 729 522 302 185 122 144 29.9 19.9 11.9 8.6 4.9 3.0 2.0 2.4 -12 -35 -60 -100 14.8 40.3 69 115 1850 4375 7500 8000 128 302 517 552 4000 4375 7500 10000 276 302 517 690 15.9 6.0 3.5 2.1 260 98 57 34 5009 1890 1103 662 82.1 31.0 18.1 10.8 -25 -40 -65 -100 -225 -55 -88 -224 27.5 43.5 73 112 253 55 88 225 3575 6000 10000 10000 25000 5500 8800 25000 246 414 690 690 1724 379 607 1724 4000 6000 10000 10000 25000 7200 10000 25000 276 414 690 690 1724 497 690 1724 14.0 8.90 5.40 3.52 1.56 14.14 8.84 3.53 229 145 88 58 26 232 145 58 2660 1691 1026 669 296 1900 1182 476 43.5 28.0 17.0 11.0 5.0 31.1 19.36 7.6 -125 -315 138 347 16000 36000 1103 2483 16000 36000 1103 2483 8.80 3.50 144.2 57.4 704 280 11.5 4.6 M, MS, 29723 4B AW, ASF, DSF, DSTV 2 hp 2 hp 2.2 3 hp ml 8.30 6.00 3.83 2.13 1.28 0.64 0.42 0.29 0.29 0.22 DSXHF DXHF, DSXHF GWD, GSFD, DGSFD, DGSTVD 6 hp cu in 506 366 234 130 78 39 25 18 18 14 HF, HSF, DSHF GW, GSF, DGSF, DGSTV 8SFD, 8DSFD, 8DSTVD 8SFD 8 hp bar 13.6 9.8 5.9 3.3 2.0 1.0 0.60 0.40 0.40 0.34 ATV 8DSFD 8HSFD 8SFD2 (Double Air Drive Piston Models) 10 hp psi 0.83 0.60 0.36 0.20 0.12 0.06 0.039 0.023 0.023 0.021 HF Double bar 43 62 103 179 310 607 931 1034 1034 1723 HF, HSF, DSHF Triple psi 625 900 1500 2600 4500 8800 13500 15000 10000 25000 AW, ASF, DSF, DSTV 100 psi/7 bar Maximum Flow 43 62 103 179 310 607 931 1034 1034 1380 DSTV ATV, DTN, DTV 150 psi/10.5 bar Displacement/Cycle 625 900 1500 2600 4500 8800 13500 15000 10000 20000 M, MS 29723 MS Single Intermittent 5.6 7.8 14 25 41 82 126 217 217 220 M, MS 125 psi/8.6 bar Continuous -5 -7 -12 -21 -36 -71 -110 -188 -188 -220 M, MDSTV 6 Ratio Dash Actual Area no. Ratio D14STD, D14SFD Typical Performance using 100 psi (7 bar) Air drive Outlet Pressure Outlet Flow Outlet Pressure Outlet Flow psi bar cu in/min l/min psi bar cu in/min l/min 225 300 700 1500 1700 2450 3000 7500 5000 5000 7500 15.5 21 48 103 117 169 207 517 345 345 517 500 350 200 90 70 tbd 40 20 18 18 15 8.20 5.70 3.28 1.48 1.15 tbd 0.64 0.33 0.30 0.30 0.24 415 600 1125 2000 3100 4500 6000 10000 10000 10000 15000 29 41 78 138 214 310 414 690 690 690 1034 249 160 100 48.9 39.6 tbd 19 8.5 14 14 12 4.09 2.6 1.64 0.8 0.65 tbd 0.31 0.14 0.23 0.23 0.2 700 1500 1750 2000 5000 48 103 121 138 345 400 200 170 110 57 6.55 3.28 2.78 1.80 0.93 1450 3000 3500 5000 10000 100 207 241 345 690 61 62 82 66 26 1.00 1.00 1.33 1.08 0.43 50 100 400 750 1000 2000 3000 4000 7000 7000 7500 15000 36000 3 7 28 52 69 138 207 276 483 483 517 1034 2483 5000 1953 1000 598 403 350 152 100 59.7 59.7 39.6 29.9 14.6 81.9 32 16.4 9.8 6.6 4.1 2.5 1.64 0.98 0.98 0.65 0.49 0.24 150 400 990 1600 2500 3600 6200 10000 15000 15000 24000 27000 45000 10 28 68 110 172 248 427 690 1034 1034 1655 1862 3103 1000 750 500 200 195 98 50 24.4 29.9 29.9 9.8 20.1 9.2 16.4 12.3 8.19 3.28 3.2 1.6 0.82 0.4 0.49 0.49 0.16 0.33 0.15 200 400 700 1900 2000 4000 7000 10000 10000 15000 14 28 48 131 138 276 483 690 690 1034 1953 799 500 299 226 122 91.5 45.2 34.8 24.4 32 13.1 8.2 4.9 3.7 2.0 1.5 0.7 0.6 0.4 800 2100 3000 5000 7500 12000 20000 30000 40000 50000 28 145 207 345 517 828 1379 2069 2759 3448 750 200 152 98 50 40.2 20.1 15.2 15.2 12.2 12.3 3.28 2.50 1.60 0.82 0.66 0.33 0.25 0.25 0.2 15000 15000 16000 1034 1034 1103 19.5 15.9 9.2 0.32 0.26 0.15 60000 70000 90000 4138 4828 6207 4.9 5.5 3.1 0.08 0.09 0.05 1000 69 348 5.7 5500 379 152 2.5 500 750 1000 1500 3000 5000 7500 10000 34 52 69 1034 138 345 517 690 1520 1030 662 465 248 151 103 63 24.9 16.9 10.9 7.6 4.1 2.5 2.0 1.0 1000 1500 2500 3500 6000 10000 15000 20000 69 103 172 248 414 690 1034 1379 380 260 162 100 56 41 27 47 6.22 4.26 2.66 1.64 0.92 0.67 0.44 0.77 200 1000 2000 2000 14 69 138 138 5004 1770 976 573 82 29 16 9.4 1200 3500 5500 10000 83 241 379 690 1454 600 397 195 24 9.8 6.5 3.2 1000 2000 3000 5000 10000 2500 4000 10000 69 138 207 345 690 172 276 690 2400 1420 880 555 270 1230 850 315 39.3 23.2 14.4 9.1 4.4 20.1 13.9 5.2 2500 4000 6000 10000 20000 4000 5000 18500 172 276 414 690 1379 276 345 1276 280 200 310 163 144 675 800 140 4.6 3.27 5.08 2.67 2.36 11 13.1 2.3 8000 15000 552 1034 488 238 8.0 3.9 12000 30000 828 2069 195 79.3 3.2 1.3 Pump Selection Information All Haskel pumps are identified by letters coding the type of pump, followed by a number indicating the practical working ratio of the drive area to the hydraulic plunger area. These letters are explained in the chart below. Pump Model Letter Coding M .875” stroke .33 hp miniature pump series S Stainless steel hydraulic piston and body 29723 .33 hp Chemical Pump D (Prefix) Pump incorporates a Distance Piece D (Suffix) Double Acting pump 4B 1” stroke .75 hp pump series (bottom inlet only) A 2” stroke 1.5 + 2 hp pump series H 2” stroke 1.5 + 2 hp High Pressure pump series XH 2” stroke 1.5 + 2 hp Extreme High Pressure pump series G 4.5” stroke 6 hp pump series B 4.5” stroke 8 hp pump or booster series 14 4” stroke 10 hp pump series W Polyurethane U-cup dynamic seal F UHMWPE (Ultra-high Molecular Weight Polyethylene Dynamic Seal T Reinforced Teflon® dynamic seal V Viton® o-ring static seal Guidelines for 24/7 Continuous Duty Applications for Maximizing Seal Life Performance Pump Series Maximum Cycles per Minute 0.3 hp 90 cpm 0.75 hp 80 cpm 1.5, 2.0 and 2.2 hp (Single and Double Drive Piston) 60 cpm 2.0 hp (Triple Drive Piston) 60 cpm 3.0 hp 60 cpm 6.0 hp 40 cpm 8.0 hp 40 cpm 10.0 hp 40 cpm www.haskel.com 7 .33 hp (.25 kW) M Series Pump Models Model Nominal Ratio Maximum Working Pressure Consult chart on page 6 for more information regarding continuous/intermittent pressures. Displacement per Cycle M, MDSTV -5 625 psi (43 bar) M, MS -7 900 psi (62 bar) .6 cu in (9.8 ml) -12 1500 psi (103 bar) .36 cu in (5.9 ml) M, MS, -21 2600 psi (179 bar) .2 cu in (3.3 ml) 29723* -36 4500 psi (310 bar) .12 cu in (2.0 ml) -71 8800 psi (607 bar) .06 cu in (1.0 ml) -110 13500 psi (931 bar) .039 cu in (0.6 ml) -188 15000 psi (1034 bar) .023 cu in (.4 ml) -220 25000 psi (1723 bar) .021 cu in (.34 ml) MS .83 cu in (13.6 ml) *Note: 29723 series rated to 10,000 psi (690 bar) maximum (ratios -110 and -188) Key Features • Choice of 6 models, 9 ratios, 27 possible combinations • Flows to 2 gpm (7.5 l/min) • Choice of wetted materials • Single air head • Pressures to 25,000 psi (1724 bar) • All Hydraulic fluids, water (plain or DI), solvents, mild chemicals, liquefied gases • Drive pressure 25 to 125 psi (1.8 to 9 bar) Optional Modifications 8 Number Description -HP Hand pump attachment (with handle). Provides manual operation of pump for precision pressure control or use without air power 26220-2 Hand pump attachment kit. 29002 Viton air drive. 51331 EPR seals for liquid section for 29723-XX ratio pumps. 51788 Piped exhaust – standard. Provides connection ports for drive and pilot exhausts. Enables under tank top mounting and/or natural gas drive. 51794 Piped exhaust – sour gas. With hand pump (HP). 51794-2 Piped exhaust – sour gas. Without hand pump (HP). 53175 Level II cleaning. 53304 High pressure outlet port. Fits ¼” O.D. high pressure threaded and coned tube. 53935 Low temperature drive. Enables operation down to 5°F. Some sacrifice of seal life at normal temperature. M or MS series. 57905 No return spring. Provides improved fill on suction stroke pumping liquefied gases by utilizing the inlet pressure. Only available on M and MS series. 59888 Cycle timer installed. 80103 82367 Noise reduction kit fitted. SS trim for 1⁄3 hp drive www.haskel.com For service codes, see page 17. For weights and dimensions, see page 18. .75 hp (.56 kW) Pump Models Maximum Working Pressure Model Nominal Ratio 4B -14 1500 psi (103 bar) .9 cu in (14.8 ml) -30 3200 psi (221 bar) .43 cu in (7.1 ml) -37 3800 psi (262 bar) .35 cu in (5.7 ml) -55 6000 psi (414 bar) .22 cu in (3.6 mil) -100 10600 psi (731 bar) .13 cu in (2.1 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures. Displacement per Cycle For service codes, see page 17. For weights and dimensions, see page 18. Key Features • One model available in 5 ratios • Choice of wetted materials • Output pressures to 10,000 psi (690 bar) • Drive pressure 3 psi to 100 psi (.2 to 7 bar) • Single air head • Flows to 1.5 gpm (5.7 l/min) Optional Modifications Number Description 57639 Low drive air pressure. Allows user to regulate drive air to as low as 3 psi (.2 bar). 59354 Noise reduction kit fitted. 81575 Changes the “F” seal to a “W” seal. Recommend for use with water. 82104 Viton air drive. www.haskel.com 9 1.5 hp (1.12 kW) Pump Models Maximum Working Pressure Model Nominal Ratio DSTV(1) -1.5 160 psi (11 bar) 31.9 cu in (513.0 ml) ATV, -4 1200 psi (83 bar) 20.0 cu in (328.0 ml) AW, ASF, -B10 1600 psi (110 bar) 4 cu in (66.4 ml) DSF, DSTV -B15 2400 psi (165 bar) 2.7 cu in (44.3 ml) -25 4000 psi (276 bar) 1.6 cu in (26.6 ml) -35 5700 psi (393 bar) 1.2 cu in (19 ml) -60 9800 psi (676 bar) .7 cu in (11 ml) ATV -8 850 psi (59 bar) 20 cu in (328.0 ml) AW, ASF, -100 16500 psi (1138 bar) .4 cu in (6.7 ml) DSF, -150 20000 psi (1375 bar) .28 cu in (4.5 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures. Displacement per Cycle DTV(1) (2) DTN(1) Key Features • Choice of 10 models, 13 ratios, 50 possible combinations • Output pressures to 50,000 psi (3448 bar) • Choice of wetted materials • Single air head • Drive pressure 3 to 150 ps (.2 to 10 bar) • Flows to 22 gpm (83.0 l/min) DSTV HF, HSF, -151 25000 psi (1724 bar) .28 cu in (4.5 ml) DSHF -225 37000 psi (2551 bar) .18 cu in (3.0 ml) -300 50000 psi (3448 bar) .14 cu in (2.3 ml) -450 45000 psi (3403 bar) .09 cu in (1.5 ml) HF Optional Modifications 10 Number Description 16821 Low air pressure control feature. For operating at air pressures as low as 3 to 4 psi (.2 to .3 bar). Includes 28881 modification. 45 psi minimum pilot air required. 16831 Low temperature modification. For special sealing in air drive for operating temperatures from as low as -20°F up to normal +120°F. 16834 Exhaust adapter. With back pressure balance piston. 27964 Interconnecting inlet-outlet tubing. ½” female for 4:1 ratio series pumps (ATV-4 or DTV-4). 28000 Threaded vent (or purge) ports on standard distance piece. Except 1.5:1 ratio. 28881 Air pilot modification. 1⁄8” NPT. Allows remote start/stop of pump. 29376 Three-way cycling spool. For 1.5 hp and 2 hp single acting pumps, for use with CO2 29702 Single stroke modification. 51050 Extreme service cycling modification. Not recommended for long stall periods. 51056 Exhaust/pilot vent combination. 51331 EPR (Ethylene propylene) static seals in wetted section. Applies to distance piece pumps only. 51345 Sour gas drive provision to N.A.C.E. specifications. 1.5 hp to 2.2 hp distance piece pumps only, single air head and double air head. 52788 Viton seals air drive. 53925 Severe Arctic low temperature service. -25, -35, -60, -100, -150, -151, -225, -300, -450 ratios. 54885 Rotate pump body 90° from standard. 54935 SS trim for 5/3 air drive. 55516 Polyurethane (“W”) seal. For F or TV series pumps, except high output models. 59353 Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD. 82460 HNBR seals in air drive section. www.haskel.com (1) These series are “Lift” pumps and maximum outlet pressure is (air drive x pump ratio) + inlet pressure (2) DTV has poppet checks For service codes, see page 17. For weights and dimensions, see page 20. 1.5 hp (1.12 kW) High Output Flow Pumps Available in a choice of 4 models, these high output, low ratio pumps are capable of pressures to 1200 psi (82 bar) and flow rates of up to 22 gpm (83 l/min). These are “lift” pumps whereby the outlet pressure equals the air drive x the pump ratio plus the inlet pressure. Mounting Brackets All series mounting brackets have 7/16” holes (slots) for 3/8” bolts. Upper mounting brackets are not furnished as standard on single air head non-distance piece units. Dimensional Data Mounting Brackets Model DSTV-1.5 has a maximum air drive of 150 psi (10 bar) and is capable of pressures up to 160 psi (11 bar). The model ATV, DTN-4 and DTV-4 work on a maximum air drive of 150 psi (10 bar) and have a maximum intermittent pressure rating of 1200 psi (83 bar). A noise reduction modification is available for applications where noise level is an issue. Distance Piece (Separation) Pumps with prefix “D” in the model number have aluminum distance piece between the air drive and pump section (except DSTV-1.5). www.haskel.com 11 2 & 2.2 hp (1.49 & 1.64 kW) Pump Models Model 2 hp AW, ASF, DSF, DSTV • Output pressures to 100000 psi (7000 bar) • Double and triple air heads • Drive pressure 3 to 100 psi (.2 to 7 bar) 3 hp (2.24 kW) Pump Models • Output pressures to 33000 psi (2275 bar) • Flow rates to 8 gpm (30 l/min) 12 www.haskel.com -B22 3200 psi (221 bar) 4 cu in (66.4 ml) -B32 4800 psi (331 bar) 2.7 cu in (44.3 ml) -52 8000 psi (552 bar) 1.6 cu in (26.6 ml) -72 11000 psi (758 bar) 1.2 cu in (19 ml) -122 19000 psi (1310 bar) .7 cu in (11 ml) Displacement per Cycle -202 33000 psi (2275 bar) .4 cu in (6.7 ml) DSHF -302 50000 psi (3448 bar) .28 cu in (4.5 ml) DSXHF -452 70000 psi (4827 bar) .18 cu in (3.0 ml) -602 75000 psi (5171 bar) .14 cu in (2.3 ml) -683 70000 psi (4827 bar) .18 cu in (3.0 ml) -903 75000 psi (5171 bar) .14 cu in (2.3 ml) DSXHW -1373 100000 psi (6895 bar) .09 cu in (1.4 ml) AFD, DSFD, -B60 6500 psi (448 bar) 1.3 cu in (22 ml) • Choice of wetted materials When using high pressure ratio pumps the reliability of the XH models (-452 through -1373) will be improved with an air driven supercharge pump, not only to simplify priming but to reduce fatigue stresses. The higher the supercharge, the better the results. Also install a relief valve to protect the lower pressure pump from potential back pressure. Supercharging of the -1373 model is recommended. This approach will ensure a reasonable life for the seals and other wear components. Key Features • One model available in 8 ratios Consult chart on page 6 for more information regarding continuous/intermittent pressures. HF, HSF, DSXHF • Flows to 5 gpm (15 l/min) 2.2 hp Key Features • Choice of 16 models, 13 ratios, 46 possible combinations Maximum Working Pressure Nominal Ratio DFD, ASFD For service codes, see page 17. For weights and dimensions, see page 20. For service service codes, codes, see see page page 17. 17. For For For weights weights and and dimensions, dimensions, see see page page 20. 20. Maximum Working Pressure Model Nominal Ratio ASFD 10 1600 psi (110 bar) 8.1 cu in (132.8 ml) 15 2400 psi (165 bar) 5.4 cu in (88.6 ml) 25 4000 psi (276 bar) 3.3 cu in (53.2 ml) 35 5700 psi (393 bar) 2.3 cu in (38 ml) 60 9800 psi (676 bar) 1.3 cu in (22 ml) 100 16500 psi (1138 bar) .8 cu in (13.4 ml) 150 20000 psi (1379 bar) .6 cu in (9 ml) 202 33000 psi (2275 bar) .8 cu in (13.4 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures. For service codes, see page 17. For weights and dimensions, see page 21. • Single air head • Drive pressure 3 to 150 psi (.2 to 10 bar) Displacement per Cycle Optional Modifications (for 2 hp, 2.2 hp and 3 hp pump models) Number Description 16821 Assures reliable drive operation with pressures low as 3 psi as long as 20 psi or more is provided to the separate 1⁄8” NPT port. 55516 Polyurethane (“W”) seal. For F or TV series pumps, except high output models. 59353 Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD. Low temperature modification. For special sealing in air drive for operating temperatures from as low as -20°F up to normal +120°F. 55465 Ceramic Plunger -60 Ratio. 55516 Polyurethane “W” seal in “F” series pumps-except high output models. 16834 Exhaust adapter. With back pressure balance piston. 59353 Noise reduction kit fitted. Not available on AFD, DFD, ASFD or DSFD. 29376 Three-way cycling spool. For 1.5 hp and 2 hp single acting pumps. 59888 Cycle timer installed. 82460 HNBR Seals in air drive section. 16831 51050 Extreme service cycling modification. Not recommended for long stall periods. 51056 Exhaust/pilot vent combination. 51331 EPR (Ethylene propylene) static seals in wetted section. Applies to distance piece pumps only. 51345 Sour gas drive provision to N.A.C.E. specifications. 1.5 hp to 2.2 hp distance piece pumps only, single air head and double air head. 52788 Viton seals. Air drive only – 1.5 hp to 2.2 hp pumps only. 53925-4 Severe Arctic low temperature service. -10, -15, -22, -32 54885 Rotate pump body 90° from standard. Except 3 hp pump. 54935 SS trim for 5/3 air drive. www.haskel.com 13 6 hp (4.47 kW) Pump Models Maximum Working Pressure Model Nominal Ratio GWD, -12 4000 psi (276 bar) 15.9 cu in (260 ml) GW, GSF, -35 4375 psi (302 bar) 6.0 cu in (98 ml) DGSF, -60 7500 psi (517 bar) 3.5 cu in (57 ml) DGSTV -100 10000 psi (690 bar) 2.1 cu in (34.5 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures. Displacement per Cycle GSFD, DGSFD(1), DGSTVD(1) (1) Double Acting “Lift” Pumps Key Features • Choice of 10 models, 4 ratios, 20 possible combinations • Single air head – double acting • Output pressures to 10,000 psi (690 bar) • Drive pressure 3 to 125 psi (.2 to 9 bar) • Flow rates to 21 gpm (80 l/min) • All hydraulic fluids, water (plain or DI), solvents • Choice of wetted materials 8 hp (5.97 kW) Pump Models For service codes, see page 17. For weights and dimensions, see page 22. Incorporating 10 models, this heavy duty range of double acting pumps provide pressures up to 10,000 psi (690 bar) and flow rates up to 4 gpm (15 l/min). Designed to operate with air drive pressures between 40 and 125 psi (2.8 and 9 bar). For drive pressures 3 to 40 psi (.2 to 2.8 bar), order 51875-1 mod. Maximum Working Pressure Model Nominal Ratio 8SFD, -25(1) 4000 psi (276 bar) 14 cu in (229 ml) -40 6000 psi (408 bar) 9 cu in (145.3 ml) -65 10000 psi (690 bar) 5.4 cu in (88.2 ml) 8DSFD -100(1) 10000 psi (690 bar) 3.5 cu in (57.5 ml) 8SFD2 (1) -55 7200 psi (496 bar) 14 cu in (229 ml) -88 10000 psi (786 bar) 8.83 cu in (144 ml) -224 29000 psi (1724 bar) 3.5 cu in (57 ml) -225(1) 25000 psi (1724 bar) 1.6 cu in (25.5 ml) Consult chart on page 6 for more information regarding continuous/intermittent pressures. Displacement per Cycle 8DSFD, 8DSTVD 8FD 8SFD Key Features • Choice of 9 models, 8 ratios, 9 possible combinations • Pressures to 30,000 psi (2068 bar) • Flow rates to 11.5 gpm (44 l/min) 14 www.haskel.com • All hydraulic fluids, water (plain or DI), solvents, liquefied gases • Choice of wetted materials 8HSFD (1) Double Acting “Lift” Pumps • Single air head – double acting • Drive pressure 3 to 125 psi (.2 to 9 bar) For service codes, see page 17. For weights and dimensions, see page 21. 10 hp (7.46 kW) Pump Models Maximum Working Pressure Model Nominal Ratio D14STD 125(1) 16000 psi (1103 bar) 8.8 cu in (144.2 ml) 315(1) 36000 psi (2482 bar) 3.5 cu in (57.4 ml) 125(1) 16000 psi (1103 bar) 8.8 cu in (144.2 ml) 315(1) 36000 psi (2482 bar) 3.5 cu in (57.4 ml) D14SFD Displacement per Cycle Consult chart on page 6 for more information regarding continuous/intermittent pressures. (1) Double Acting “Lift” Pumps For service codes, see page 17. For weights and dimensions, see page 21. Key Features • Choice of 4 models, 4 ratios, 4 possible combinations • Pressures to 36000 psi (2500 bar) • Flow rates to 3 gpm (11 l/min) • Drive pressure 3 to 125 psi (.2 to 9 bar) • All hydraulic fluids, water (plain or DI), solvents, liquefied gases • Choice of wetted materials Optional Modifications (for 6 hp, 8 hp and 10 hp pump) Number Description 29125 External pilot modification – for 6 hp thru 10 hp pumps. 87410 Low air pressure control – for 6 hp thru 10 hp pumps. 54030 Sour gas air drive provision to NACE spec. 6 hp distance piece pumps only. 54936 Exhaust/pilot vent combiner. 57002 Viton seals – air drive only – 6 hp 57944 Viton seals – air drive only – 8 hp 59888 Cycle timer installed. Incorporating two basic models, this heavy duty range of double acting pumps provide pressures up to 36000 psi (2482 bar) and output flow rate up to 3 gpm (11 l/min). Operating from a maximum air drive pressure of 125 psi (9 bar), these pumps are designed for medium to high pressure service with minimum maintenance. These large, slow speed pumps approach a seal life as high as 5 times that of many smaller pumps and this advantage becomes ever greater in heavy duty service involving water, or other liquids with negligible lubricity. www.haskel.com 15 Power System Specialists World safety standards and quality demands are rising. Component manufacturers are required to provide test certification and product quality assurance which can only be determined using the types of systems which Haskel can provide. Typically, we have built systems for production and field testing the proof, leak, and burst aspects of hoses, cylinders, and valves. These systems can be portable, mobile, or static test rigs. We also offer a range of standard pressure packs used for power jacking, clamping, and other applications where reliable power is needed. Quality and After-Sale Service Haskel meets the requirements of international quality assurance ISO 9001. Build quality is matched by an innovative design and problem solving ability which stems from years of years of experience. Our representatives around the world are carefully chosen and trained to help you arrive at a correct product choice, and to offer a maintenance and parts service that is second to none. Selecting Your Accessories Haskel can either provide accessories separately or supply them fitted to form a complete package suited to your application. Additionally, Haskel can customer nominated accessories. Our accessories catalog is available and our technical support team is always ready to advise you on the most suitable choice of accessories for your application. • • • • • 16 Air pilot switches Air pilot valves Regulating relief valves Directional control and release valves Hydraulic accumulators, gas receivers and storage cylinders www.haskel.com • High pressure valves, fittings and tubing • Plenum chambers • Port adapters • Gauge snubbers • Filters • Stainless steel check valves Intensifiers with integral checks for cycling • Capillary type gauge snubbers Please ask for your copy of our latest accessories brochure. Liquids Compatible with Haskel Pumps To assist in easier pump selection, we have classified various popular liquids in groups and assigned to each group a service code. These service code numbers are featured in the chart to the right and are designated for each pump series. Seals and other wetted materials can be supplied to suit your preferred liquid. For advice, please contact our technical services personnel at 818-843-4000. Services hp Model M .33 MS MDSTV 29723 .75 4B -14 to -37 4B -55 to -100 5 Skydrol and Aerosafe hydraulic acetone and some alcohols (ethyl, methyl, and isopropyl). 5A. Also suitable for these if Viton static seals are replaced with EPR; specify number 51331 (no extra charge); e.g., 51331-MDTV-5. Most phosphate esterbased solidify at approximately 30000 psi. 6 Deionized water; demineralized water. Note: Dynamic seal life with non-lubricating fluids will understandably be less than with lubricating types. Drive Section -4° (25°F) to +65°C (150°F) (low temperature seals are available for Arctic operation). • • • • • • • • • HSF DSHF DSTV Liquid Section For reasonable seal life, high temperature should be limited to 54° C (130° F), for F and W seal models, 135° C (275° F) for T and TV models (with distance piece). ATV DTV DSTV-1.5 AFD DFD ASFD DSFD DSXHF GSF DGSF DGSTV GWD GSFD DGFD DGSFD DGSTVD 8FD 8SFD 8 8SFD2 8DSFD 8DSTVD 8HSFD D14STD-125 10 • • GW HF Operating Temperatures • • • DSF 6 • • • ASFD Service Codes 1 Petroleum-based oils, kerosene, ethylene glycol, water with 5% soluble oil. 2 Plain water, diesel fuel. 3 Most phosphate ester-based hydraulic e.g. Pydraul, Lindol, Cellulube, Fyrquel, and Houghtosafe 1120 and petroleum-based solvents compatible with UHMWPE (Ultra-high Molecular Weight Polyethylene) dynamic seals and Viton static seals. 4 Petroleum-based solvents, e.g. aromatic hydrocarbons (benzene, toluene, xylene, hylene, etc.); chlorinated solvents (trichlorethylene, carbon tetrachloride, chlorobenzine, etc.); solvents mercaptans, Dowtherm A, etc.); Dowtherm E, plus all of Group 3 and some mildly corrosive acids compatible with wetted materials. See note 5A for service with methylethyl-ketone, methyl acetone, diacetone, alcohol and freon 22. ASF D14STD-315 D14SFD-125 D14SFD-315 3 • • • • DSXHW AW 3 2 • • • • • • • • • • • • • • • • Services 1.5 2 2.2 1 • • • • • • • • • • • • • 4 • • 5 • 6 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • www.haskel.com 17 NB. Plan view of M-Pump is common to all M-Series pumps. Net weight 2.65 kg Boxed weight 2.9 kg Box size 23 x 18 x 12 cm 11.91 mm (.075”) Weights and Dimensions 206 mm (8”) .33 hp (.25 kW) M Series Pump Models Net weight 4 kg Boxed weight 4.25 kg Box size 23 x 18 x 12 cm M-7, M-12 approx. weight 9 lbs (4 kg) MS-7, MS-12 approx. weight 9 lbs (4 kg) Net weight 6 kg Boxed weight 6.5 kg Box size 30 x 20 x 15 cm Net weight 2.5 kg Boxed weight 2.75 kg Box size 23 x 18 x 12 cm MS-21, MS-36, MS-71, MS-110, MS-188, approx. weight 6 lbs (2.7 kg) 18 www.haskel.com M-21, M-36, M-71, M-110, M-188 approx. weight 6 lbs (2.7 kg) MS-220 approx. weight 6 lbs (2.7 kg) M-5 approx. weight 9 lbs (4 kg) 29723-21, 29723-36, 29723-71, 29723-110 approx. weight 6.5 lbs (3 kg) MDSTV-5 , MDTV Approx weight 15 1/2 lbs (7 kg) .75 hp (.56 kW) Pump Models Model 4B-14, and 4B-30 4B-21, 4B-25 and 4B-30 Model 4B-55 and 4B-75 www.haskel.com 19 KS KS N: 3XPS0RGHOV DSFD-B60 iÌÊÜi} ÌÊ£nÊ} Ýi`ÊÜi} ÌÊÓäÊ} ÝÊÃâiÊÈnÊÝÊ{ÓÊÝÊxäÊV iÌÊÜi} ÌÊ£äÊ} Ýi`ÊÜi} ÌÊ££Ê} ÝÊÃâiÊÎÇÊÝÊÎÇÊÝÊÎnÊV 25.4 mm = 1 inch 2 hp high ratio pumps; -683 and -903 ratios 1.5 and 2 hp low ratio pumps; -B10 and -B15 ratios iÌÊÜi} ÌÊ£{Ê} Ýi`ÊÜi} ÌÊ£xÊ} ÝÊÃâiÊxÓÊÝÊ{äÊÝÊ{äÊV (-52, -72, +22) ⁄4 HP port (-202, -302) 1 1.5 and 2 hp medium ratio pumps; -52, -72, -122, -202 and -302 ratios 20 www.haskel.com 2 hp (1.49 & 1.64 kW) Pump Models; -1373 ratio KS (N. : 3W XP F lRsQ (W c ont.) . 7 5 hp 5 6 k ) S P u0mRpG HMO V o d e Model 4B-37 approx. weight 10 lbs (4.5 kg) Model 4B-100 4B-100 & 4B-150 approx. weight approx. weight11 11lbs lbs(5(5kg) kg) 1.5 hp, 2&2.2 hp (1.12, 1.49 & 1.64 kW)Pump Models DSFD-B60 www.haskel.com 21 1.5 hp, 2&2.2 hp (1.12, 1.49 & 1.64 kW)Pump Models (cont.) iÌÊÜi} ÌÊ£nÊ} Ýi`ÊÜi} ÌÊÓäÊ} ÝÊÃâiÊÈnÊÝÊ{ÓÊÝÊxäÊV iÌÊÜi} ÌÊ£äÊ} Ýi`ÊÜi} ÌÊ££Ê} ÝÊÃâiÊÎÇÊÝÊÎÇÊÝÊÎnÊV 1.5 and 2 hp low ratio pumps; -B10 and -B15 ratios iÌÊÜi} ÌÊ£{Ê} Ýi`ÊÜi} ÌÊ£xÊ} ÝÊÃâiÊxÓÊÝÊ{äÊÝÊ{äÊV 25.4 mm = 1 inch 2 hp high ratio pumps; -683 and -903 ratios ⁄2” NPT (-52, -72, 122) Liquid Outlet 1 ⁄4 HP port (-202, -302) 1 394 mm ­£xÊ£ÉÓ»® Breathers ir Drive Inlet 1ÉÓ»Ê *T 1.5 and 2 hp medium ratio pumps; -52, -72, -122, -202 and -302 ratios quid Inlet £ÉÓ»Ê *T ÀÊ Ý aust 1ÉÓ»Ê *T 241 mm ­Ê£ÉÓ»® iÌÊÜi} ÌÊ£äÊ} Ýi`ÊÜi} ÌÊ££Ê} ÝÊÃâiÊ{xÊÝÊÎÇÊÝÊ{{ÊV 2 hp (1.49 & 1.64 kW) pump models; -1373 ratio iÌÊÜi} ÌÊ£nÊ} Ýi`ÊÜi} ÌÊ£Ê} ÝÊÃâiÊ{xÊÝÊÎÇÊÝÊ{{ÊV ATV-4 pumps; double acting, high output Ìi\ÊÀÊ`iÊ /6-4, add distance piece dimension from page 11. Interconnecting inlet and outlet port tubing shown. 22 www.haskel.com DSTV-1.5 pump; single acting, high output quid Outlet 3É{»Ê*Ê*Àt 24x mm ­ÊxÉn»® iÌÊÜi} ÌÊ°xÊ} Ýi`ÊÜi} ÌÊ£äÊ} ÝÊÃâiÊÓxÊÝÊÓÈÊÝÊÓÓÊV 11 mm (7/16”) (TYP) (9 7/8”) 119 mm (4 11/16”) Mounting Bracket (2 places) 76 mm (3”) Handle ⁄2” NPT Liquid Outlet* 1 279 mm (11”) 413 mm (15 1/4”) Air Drive Exhaust Port 1/2” NPT 64 mm (2 1/2”) Air Drive Inlet Port 1/2” NPT 154 mm 17 mm (6 1/16”) (11/16”) 1.5 and 2 hp medium and high ratios; -25 through -150, -151*, -225*, -300* and -450* ratios *1⁄4” Super Pressure Outlet Port Hydraulic Outlet Port 1/2” NPT (2 places, this side) 144 mm (5 11/16”) 105 mm (4 5/32”) (TYP) Hydraulic Inlet Port 1/2” NPT (2 places, this side) 102 mm (4”) 209 mm (8 1/4”) ATV-8 pumps AFD or ASFD, -B60, -B100 pumps; double acting, high output 3 hp (2.24 kW) Pump Models AIR DRIVE INLET PORT 1/2” NPT MODEL ASFD-15 OUTLET PORT 1/2” NPT OUTLET PORT INLET PORT ASFD-25 ASFD-25ASFD-35, ASFD-35ASFD-60 1/2” NPT ASFD-100 3⁄8" med. ASFD-60ASFD-150 pressure 1/2” NPT } ASFD-100 OUTLET PORT 1/2” NPT ASFD-150 3/8” MEDIUM PRESSURE 9/16-18 THREAD ASFD-10 ASFD-202 OUTLET PORT 1/2” NPT www www.haskel.com 23 KS N: 3XPS0RGHOV iÌÊÜi} ÌÊΣÊLÃÊ­£{Ê}® Ýi`ÊÜi} ÌÊÎxÊLÃÊ­£ÈÊ}® ÝÊÃâiÊxÓÊÝÊÎÊÝÊÎÊV Ê`iÃÊ >ÛiÊÓÊvvÊ11⁄4” */Ê>ÀÊiÝ >ÕÃÌÊ«ÀÌÃÊ and 1 off 3⁄4»Ê */Ê>ÀÊ`ÀÛiÊ inlet ports. Models GW, GSF nominal ratio 35, 60 100:1 iÌÊÜi} ÌÊ{£ÊLÃÊ­£n°xÊ}® Ýi`ÊÜi} ÌÊ{nÊ­ÓÓÊ}® ÝÊÃâiÊÈÈÊÝÊ{£ÊÝÊ{ÊV DGSTV nominal ratio 35, 60 100:1 Models DGSF, DGF, DGSF, DGSTV nominal ratio 35, 60 100:1 iÌÊÜi} ÌÊxÇÊLÃÊ­ÓÈÊ}® Ýi`ÊÜi} ÌÊȣʭÓÇÊ}® ÝÊÃâiÊÈÈÊÝÊ{£ÊÝÊ{ÊV If interconnecting piping for the two inlets and two outlets is required, specify modifiV>ÌÊÓäÇÇÊÜÌ ÊÞÕÀÊÀ`ir. Models GWD, GSFD nominal ratio 12:1 iÌÊÜi} ÌÊÈÈÊLÃÊ­ÎäÊ}® Ýi`ÊÜi} ÌÊÇxÊLÃÊ­Î{Ê}® ÝÊÃâiÊ£ÊÝÊx£ÊÝÊÎÊV If interconnecting piping for the two inlets and two outlets is required, specify modifiV>ÌÊÓäÇnÊÜÌ ÊÞÕÀÊÀ`ir. Models DGSFD, DGFD, DGSFD, nominal DGSTV DGSTVD nominal ratio 12:1 ratio 12:1 24 www.haskel.com 8 hp (5.97 kW) Pump Models 9.65 [245 mm] 27.66 [703 mm] 5.21 [132 mm] AIR DRIVE INLET PORT 3/4" NPT (130 PSIG MAX) 22.93 [582 mm] CYCLING SPOOL ACCESS 2X LIQUID INLET PORT 3/8" HIGH PRESSURE (25,000 PSIG MAX) 10.96 [278 mm] 10.17 [258 mm] 2X AIR DRIVE/SEAL SECTION VENT PORT 1/4" NPT 4.88 [124 mm] 2X LIQUID OUTLET PORT 3/8" HIGH PRESSURE (25,000 PSIG MAX) 7.00 [178 mm] 8.25 [210 mm] 5.78 [147 mm] 11.36 [288 mm] 4X MOUNTING HOLES n 9/16" Model Models8HSFD-25 8HSFD-25, 8FD-25, 8SFD-25 Inlet,Outlet Outletports ports3/8” 3/8’’HP HP Inlet, Models 8DSFD-25 & 8DSTVD-25 Model 8SFD-40 Model 8SFD-65 www.haskel.com 25 KS N: 3XPS0RGHOV FRQW 8X .53 in [13 mm] (MOUNTING HOLES 32.73 in [831 mm] 9.65 in [245 mm] AIR DRIVE INLET 3/4 NPT 2X HYDRAULIC OUTLET 1" NPT PORT 11.10 in [282 mm] 10.17 in [258 mm] 4.88 in [124 mm] 2X HYDRAULIC INLET 1 1/4" NPT PORT 4.25 in [108 mm] 18.11 in [460 mm] 7.00 in [178 mm] 19.55 in [496 mm] 8.25 in [210 mm] 26.48 in [673 mm] 29.92 in [760 mm] Model 8SFD2-55 8X .53 in [13 mm] (MOUNTING HOLES) 9.65 in [245 mm] 33.80 in [858 mm] AIR DRIVE LET 3/4 NPT 2X HYDRAULIC OUTLET 1" NPT PORT 11.10 in [282 10.17 in [258 mm] 4.88 in [124 mm] 2X HYDRAULIC INLET 1 1/4" NPT PORT 18.11 in [460 mm] 19.55 in [496 mm] 28.62 in [727 mm] 32.06 in [814 mm] Model 8SFD2-88 26 www.haskel.com 4.25 in [108 mm] 7.00 in [178 mm] 8.25 in [210 mm] HYDRAULIC OUTLET 3/8 HP PORT (MAWP: 29,000 PSI) HYDRAULIC INTLET 1/2 NPT PORT (MAWP: 10,000 PSI) HYDRAULIC OUTLET 3/8 HP PORT (MAWP: 29,000 PSI) HYDRAULIC INLET 1/2 NPT PORT (MAWP: 10,000 PSI) 8X .53 in [13 mm] (MOUNTING HOLES) 9.65 in [245 mm] AIR DRIVE INLET 3/4 NPT 11.10 in [282 mm] 10.17 in [258 mm] 4.88 in [124 mm] 18.11 in [460 mm] 4.25 in [108 mm] 19.55 in [496 mm] 7.00 in [178 mm] 35.78 in [909 mm] 37.78 in [960 mm] 8.25 in [210 mm] Model 8SFD2-224 10 hp (7.46 kW) Pump Models Model D14STD-125 Model D14STD-315 www.haskel.com 27 For more information on our high-pressure products, visit Haskel.com or contact your local Haskel representative. Haskel is a brand of Accudyne Industries, a leading global provider of precision-engineered, process-critical and technologically advanced flow control systems and industrial compressors that deliver consistently high performance and give confidence to the mission of our customers in the most important industries and harshest environments around the world. The company is powered by more than 3,000 employees at 18 manufacturing facilities, supporting a broad range of industries in more than 150 countries. haskel.com l.co com om m [email protected] sales@haskel skel kel.c l.co com om m LP-GL 04/17 Printed in USA