DECLARATION OF CONFORMITY
DECLARACIÓN DE CONFORMIDAD
www.basor.com
The company / La Empresa:
BASOR ELECTRIC, S.A.
Address / Dirección:
Av. Alcodar, 45-47, 46700. Gandía (VLC), Spain.
Declares that the product:
Declara que el producto:
BASORTRAV FE
Installed in accordance to the installa!on standards, manufacturer’s instruc!ons and professional rules, duly maintained
and used for the applica!ons as intended.
Instalado de acuerdo con las normas de instalación, instrucciones del fabricante y conforme a las reglas profesionales,
debidamente mantenido y u!lizado en las aplicaciones para las que está previsto.
Complies with the essen!al requirements of the Council Direc!ves:
Cumple con los requisitos esenciales de las Direc!vas del Consejo:
2014/35/UE (Low Voltage Direc!ve) / (Direc•va de Baja Tensión)
Incorporated in the Spanish Legisla!on in: R.D. 7/1988 and its modifica!on R.D. 154/1995.
Incorporado en la Legislación Española en: R.D. 7/1988 y su modificación R.D. 154/1995.
And it is suitable and safe for the intended use and it is in conformity with the following standard:
Es adecuado y seguro para el uso a que está des!nado y es conforme con la siguiente norma:
UNE EN 61537
Addi!onal informa!on:
Información adicional:
This product is intended to be installed and maintained by skilled persons, it may be used by ordinary persons only as a
replacement part, to subs!tute for an iden!cal device.
Este producto está previsto para ser instalado y mantenido por un profesional, puede ser usado por una persona no formada
para reemplazamiento de uno idén!co.
Place and date:
Lugar y fecha:
Gandía April 2016
Gandía Abril 2016
Technical department / Departamento Técnico
78
DATA SHEET
BASORTRAV FE H75/100/120/150
www.basor.com
UNE-EN 61537
REV.20/04/2016
FE H75/100/120/150
ER 50x50+TAPA
Models (BxH):
100x75; 150x75; 200x75; 300x75; 400x75; 500x75; 600x75; 100x100; 150x100;
200x100; 300x100; 400x100; 500x100; 600x100; 150x120; 200x120; 300x120;
400x120; 500x120; 600x120; 150x150; 200x150; 300x150; 400x150; 500x150;
600x150.
Nota: All the models available with 9 or 12 rungs.
Material: HGC
Characteristics of the tray:
- Metallic
FE H75/100/120
Classification according to free
base area:
Base Models
Clasification
100
X
150
X
- Electrically conductive component
200
Y
- Minimum temperature of -50 ˚C
300
Y
- Maximum temperature of 150 ˚C
400
Y
500
Y
600
Y
- Non-flame propagating component
- System with electrical continuity
- With metallic coating; resistance to corrosion:
HDG coating: class 6
- Impact Strength: 20J
Models 200 & 300 Clasification
X with 250 mm rung spacing
FE H150
MOUNTING INSTRUCTIONS
- For the set-up of the self-assembly system, 4 B2 Bolt sets (8 for trays with
H150) and no union joint plates are needed.
- The tray installation for an electrical system should NOT run under other
types of canalisations such as water, vapour or gas canalisations.
- To guarantee a good ventilation, we recommend installing the trays keeping
a minimum distance of 250 mm between each tray.
- Trays which are placed on supports shall have to keep a gap of 20 mm from
the wall to allow for a correct ventilation of the cables.
FE H75/100/120
FE H150
Accesories:
This family has large array of accessories: Cover, cover clamp, divider, horizontal bend, vertical inside/outside bends, T intersection, cross intersection,
reductions, FE cable ladder clamp, union joint plates, articulated union joints, horizontal angle joints.
The standard radius of the accesories is 300 mm. Ask us for accesories with different radius.
This technical data sheet issued accordingly to the fulfillment of the product Standard, is itself a necessary analyses of the electric risks according to the low tension Directive 2014/35/UE of February 26th 2014, in effect from April 20th 2016
80
SAFE WORKING LOAD
FE H=75 mm dtrav=333mm
FE H=100 mm d=333 mm
500
350
CTA L6
CTA L3
Def
300
70
450
60
400
50
CTA L3
CTA L6
Def
LIM CTA B=500
40
LIM CTA B=600
40
150
30
CTA (Kg/m)
50
200
300
30
250
200
20
Def (mm)
250
Def (mm)
CTA (Kg/m)
350
150
100
20
50
10
100
0
2.5
3.0
3.5
4.0
d (m)
4.5
5.0
5.5
550
450
50
200
CTA (Kg/m)
250
4.5
5.0
5.5
6.0
CTA L3
CTA L6
Def
80
60
LIM CTA B=750
500
LIM CTA B=900
400
40
300
20
200
150
100
Def (mm)
30
Def (mm)
300
4.0
d (m)
LIM CTA B=600
600
40
350
3.5
LIM CTA B=500
700
LIM CTA B=900
400
3.0
FE H=150 mm d=333 mm
800
CTA L3
CTA L6
Def
LIM CTA B=750
2.5
900
60
500
0
2.0
6.0
FE H=120 mm d=333 mm
600
CTA (Kg/m)
0
0
2.0
10
50
10
20
100
50
0
0
0
2.0
2.5
3.0
3.5
4.0
d (m)
4.5
5.0
5.5
0
2.0
6.0
FE H=75 mm dtrav=250mm
2.5
3.0
CTA L6
CTA L3
Def
300
4.0
d (m)
4.5
5.0
5.5
6.0
FE H=100 mm d=250 mm
500
350
3.5
50
LIM CTA B=600 - 446 kg/m
70
450
60
400
CTA L3
CTA L6
Def
40
200
40
150
30
CTA (Kg/m)
50
300
30
250
200
20
Def (mm)
250
Def (mm)
CTA (Kg/m)
350
150
100
20
50
10
100
0
0
0
2.0
2.5
3.0
3.5
4.0
d (m)
4.5
5.0
5.5
550
LIM CTA B=900
500
200
20
150
CTA (Kg/m)
30
250
4.5
5.0
5.5
6.0
CTA L3
CTA L6
Def
80
60
LIM CTA B=900
500
40
400
300
200
100
Def (mm)
300
Def (mm)
CTA (Kg/m)
600
40
4.0
d (m)
LIM CTA B=750
700
450
3.5
FE H=150 mm d=250 mm
800
350
3.0
LIM CTA B=600
50
400
2.5
900
60
CTA L3
CTA L6
Def
0
2.0
6.0
FE H=120 mm d=250 mm
600
10
50
20
10
100
50
0
0
2.0
2.5
3.0
3.5
4.0
d (m)
4.5
5.0
5.5
6.0
0
0
2.0
2.5
3.0
3.5
4.0
d (m)
4.5
5.0
5.5
6.0
This technical data sheet issued accordingly to the fulfillment of the product Standard, is itself a necessary analyses of the electric risks according to the low tension Directive 2014/35/UE of February 26th 2014, in effect from April 20th 2016