DECLARATION OF CONFORMITY DECLARACIÓN DE CONFORMIDAD www.basor.com The company / La Empresa: BASOR ELECTRIC, S.A. Address / Dirección: Av. Alcodar, 45-47, 46700. Gandía (VLC), Spain. Declares that the product: Declara que el producto: BASORTRAV FE Installed in accordance to the installa!on standards, manufacturer’s instruc!ons and professional rules, duly maintained and used for the applica!ons as intended. Instalado de acuerdo con las normas de instalación, instrucciones del fabricante y conforme a las reglas profesionales, debidamente mantenido y u!lizado en las aplicaciones para las que está previsto. Complies with the essen!al requirements of the Council Direc!ves: Cumple con los requisitos esenciales de las Direc!vas del Consejo: 2014/35/UE (Low Voltage Direc!ve) / (Direc•va de Baja Tensión) Incorporated in the Spanish Legisla!on in: R.D. 7/1988 and its modifica!on R.D. 154/1995. Incorporado en la Legislación Española en: R.D. 7/1988 y su modificación R.D. 154/1995. And it is suitable and safe for the intended use and it is in conformity with the following standard: Es adecuado y seguro para el uso a que está des!nado y es conforme con la siguiente norma: UNE EN 61537 Addi!onal informa!on: Información adicional: This product is intended to be installed and maintained by skilled persons, it may be used by ordinary persons only as a replacement part, to subs!tute for an iden!cal device. Este producto está previsto para ser instalado y mantenido por un profesional, puede ser usado por una persona no formada para reemplazamiento de uno idén!co. Place and date: Lugar y fecha: Gandía April 2016 Gandía Abril 2016 Technical department / Departamento Técnico 78 DATA SHEET BASORTRAV FE H75/100/120/150 www.basor.com UNE-EN 61537 REV.20/04/2016 FE H75/100/120/150 ER 50x50+TAPA Models (BxH): 100x75; 150x75; 200x75; 300x75; 400x75; 500x75; 600x75; 100x100; 150x100; 200x100; 300x100; 400x100; 500x100; 600x100; 150x120; 200x120; 300x120; 400x120; 500x120; 600x120; 150x150; 200x150; 300x150; 400x150; 500x150; 600x150. Nota: All the models available with 9 or 12 rungs. Material: HGC Characteristics of the tray: - Metallic FE H75/100/120 Classification according to free base area: Base Models Clasification 100 X 150 X - Electrically conductive component 200 Y - Minimum temperature of -50 ˚C 300 Y - Maximum temperature of 150 ˚C 400 Y 500 Y 600 Y - Non-flame propagating component - System with electrical continuity - With metallic coating; resistance to corrosion: HDG coating: class 6 - Impact Strength: 20J Models 200 & 300 Clasification X with 250 mm rung spacing FE H150 MOUNTING INSTRUCTIONS - For the set-up of the self-assembly system, 4 B2 Bolt sets (8 for trays with H150) and no union joint plates are needed. - The tray installation for an electrical system should NOT run under other types of canalisations such as water, vapour or gas canalisations. - To guarantee a good ventilation, we recommend installing the trays keeping a minimum distance of 250 mm between each tray. - Trays which are placed on supports shall have to keep a gap of 20 mm from the wall to allow for a correct ventilation of the cables. FE H75/100/120 FE H150 Accesories: This family has large array of accessories: Cover, cover clamp, divider, horizontal bend, vertical inside/outside bends, T intersection, cross intersection, reductions, FE cable ladder clamp, union joint plates, articulated union joints, horizontal angle joints. The standard radius of the accesories is 300 mm. Ask us for accesories with different radius. This technical data sheet issued accordingly to the fulfillment of the product Standard, is itself a necessary analyses of the electric risks according to the low tension Directive 2014/35/UE of February 26th 2014, in effect from April 20th 2016 80 SAFE WORKING LOAD FE H=75 mm dtrav=333mm FE H=100 mm d=333 mm 500 350 CTA L6 CTA L3 Def 300 70 450 60 400 50 CTA L3 CTA L6 Def LIM CTA B=500 40 LIM CTA B=600 40 150 30 CTA (Kg/m) 50 200 300 30 250 200 20 Def (mm) 250 Def (mm) CTA (Kg/m) 350 150 100 20 50 10 100 0 2.5 3.0 3.5 4.0 d (m) 4.5 5.0 5.5 550 450 50 200 CTA (Kg/m) 250 4.5 5.0 5.5 6.0 CTA L3 CTA L6 Def 80 60 LIM CTA B=750 500 LIM CTA B=900 400 40 300 20 200 150 100 Def (mm) 30 Def (mm) 300 4.0 d (m) LIM CTA B=600 600 40 350 3.5 LIM CTA B=500 700 LIM CTA B=900 400 3.0 FE H=150 mm d=333 mm 800 CTA L3 CTA L6 Def LIM CTA B=750 2.5 900 60 500 0 2.0 6.0 FE H=120 mm d=333 mm 600 CTA (Kg/m) 0 0 2.0 10 50 10 20 100 50 0 0 0 2.0 2.5 3.0 3.5 4.0 d (m) 4.5 5.0 5.5 0 2.0 6.0 FE H=75 mm dtrav=250mm 2.5 3.0 CTA L6 CTA L3 Def 300 4.0 d (m) 4.5 5.0 5.5 6.0 FE H=100 mm d=250 mm 500 350 3.5 50 LIM CTA B=600 - 446 kg/m 70 450 60 400 CTA L3 CTA L6 Def 40 200 40 150 30 CTA (Kg/m) 50 300 30 250 200 20 Def (mm) 250 Def (mm) CTA (Kg/m) 350 150 100 20 50 10 100 0 0 0 2.0 2.5 3.0 3.5 4.0 d (m) 4.5 5.0 5.5 550 LIM CTA B=900 500 200 20 150 CTA (Kg/m) 30 250 4.5 5.0 5.5 6.0 CTA L3 CTA L6 Def 80 60 LIM CTA B=900 500 40 400 300 200 100 Def (mm) 300 Def (mm) CTA (Kg/m) 600 40 4.0 d (m) LIM CTA B=750 700 450 3.5 FE H=150 mm d=250 mm 800 350 3.0 LIM CTA B=600 50 400 2.5 900 60 CTA L3 CTA L6 Def 0 2.0 6.0 FE H=120 mm d=250 mm 600 10 50 20 10 100 50 0 0 2.0 2.5 3.0 3.5 4.0 d (m) 4.5 5.0 5.5 6.0 0 0 2.0 2.5 3.0 3.5 4.0 d (m) 4.5 5.0 5.5 6.0 This technical data sheet issued accordingly to the fulfillment of the product Standard, is itself a necessary analyses of the electric risks according to the low tension Directive 2014/35/UE of February 26th 2014, in effect from April 20th 2016 81