TABLA DE SELECCIÓN DE CONDENSADOR DE ARRANQUE Y MARCHA POTENCIA ARRANQUE MARCHA 1/8 HP 72-88 MFD 110VCA 75-90 MFD 110VCA 5 MFD 370 VCA 6 MFD 370 VCA 1/6 HP 86-100 MFD 110VCA 7.5 MFD 370 VCA 1/4 HP 108-130 MFD 110 VCA 124-149 MFD 110 VCA 10 MFD 370 VCA 1/3 HP 161-193 MFD 110 VCA 12.5 MFD 370 VCA 15 MFD 370 VCA 1/2 HP 200-249 MFD 110 VCA 216-259 MFD 110 VCA 15 MFD 370 VCA 3/4 HP 324-388 MFD 110 VCA 340-408 MFD 110 VCA 145-154 MFD 110 VCA 17.5 MFD 370 VCA 20 MFD 370 VCA 1 HP 378-440 MFD 110 VCA 400-480 MFD 110 VCA 20 MFD 370 VCA 1.5 HP 540-648 MFD 110 VCA 75-90 MFD 250 VCA 81-97 MFD 250 VCA 108-130 MFD 250 VCA 25 MFD 370 VCA 2 HP 645-694 MFD 110 VCA 127-152 MFD 250 VCA 135-162 MFD 250 VCA 708-822 MFD 110 VCA 20 MFD 370 VCA 25 MFD 370 VCA 30 MFD 370 VCA 35 MFD 370 VCA 3 HP 708-822 MFD 110 VCA 829-995 MFD 110 VCA 130-162 MFD 250 VCA 145-152 MFD 250 VCA 35 MFD 370 VCA 40 MFD 370 VCA 5 HP 829-995 MFD 110 VCA 1000-1200 MFD 110 VCA 161-193 MFD 250 VCA 270-324 MFD 250 VCA 40 MFD 370 VCA 50 MFD 370 VCA Notas: 1. Usar la tabla como referencia, no son valores definitivos. 2. Se puede usar la siguiente fórmula: MFD arranque= (3150 * Amperaje del motor) / Voltaje del motor