CERTIFICATE OF COMPLIANCE Wilsonart LLC 1110-420 Wilsonart® Laminate 01/31/2006 - 03/09/2016 Certificate Number Certificate Period Certified Status UL 2818 -2013 Gold Standard for Chemical Emissions for Building Materials, Finishes and Furnishings Product tested in accordance with UL 2821 test method to show compliance to emission limits on UL 2818. Section 7.1 and 7.2. Building products and Interior finishes are determined compliant in accordance with California Department of Public Health (CDPH) Standard Method V1.1-2010 using the applicable exposure scenario(s). UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement. GREENGUARD Gold Certification Criteria for Building Products and Interior Finishes Criteria TVOC (A) Formaldehyde Total Aldehydes (B) 4-Phenylcyclohexene Particle Matter less than 10 µm (C) 1-Methyl-2-pyrrolidinone (D) Individual VOCs (E) CAS Number Maximum Allowable Predicted Concentration Units - 0.22 mg/m³ 50-00-0 9 (7.3 ppb) µg/m³ - 0.043 ppm 4994-16-5 6.5 µg/m³ - 20 µg/m³ 872-50-4 160 µg/m³ - 1/2 CREL or 1/100th TLV - (A) Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. (B) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis. (C) Particle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems. (D) Based on the CA Prop 65 Maximum Allowable Dose Level for inhalation of 3,200 ʅg/day and an inhalation rate of 20 m³/day (E) Allowable levels for chemicals not listed are derived from the lower of 1/2 the California Office of Environmental Health Hazard Assessment (OEHHA) Chronic Reference Exposure Level (CREL) as required per the CDPH/EHLB/Standard Method v1.1 and BIFMA level credit 7.6.2 and 1/100th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinnati, OH 45211-4438). UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively “Agreement”). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.