Foreign body like reason of failure in bladder catheterization

Anuncio
actas urol esp. 2010;34(5):489–491
491
Foreign body like reason of failure in bladder catheterization
Cuerpo extraño como causa de fracaso en el sondaje vesical
Figures 1 and 2 – Foreign body at urethral bulb level (photo 1). The foreign body belongs to the plug of a urological
lubricant tube (photo 2).
J. Subirá Ríos*, B. Blasco Beltrán, J. Navarro Gil,
I. Hijazo Conejos, and J.G. Valdivia Uría
*Author for correspondence.
E-mail: [email protected] (J. Subirá Ríos).
Department of Urology, Hospital Clínico Universitario Lozano
Blesa, Saragossa, Spain
Vesicosigmoidal fistula secondary to sigmoid diverticula
Fístula colovesical secundaria a divertículos sigmoideos
Figure 1 – Barium meal enema showing multiple
diverticula in sigmoid colon and filling of urinary bladder
with barium contrast suggesting colovesical fistula.
Figure 2 – Passage of fecaloid material into the bladder
confirms diagnosis.
R. Gil Ugarteburu*, I. González Rodríguez, I. Fernández García, A. Martín Huescar, L. Rodríguez Villamil,
and V. Muruamendiaraz Fernández
*Author for correspondence.
E-mail: [email protected] (R. Gil Ugarteburu).
Department of Urology, Hospital Cabueñes, Gijón, Asturias, Spain