PASSENGER ELEVATORS Principle Based on our policy, “Quality in Motion”, Welcome to a New Era in Vertical Transportation Introducing the NEXIEZ... we provide elevators and escalators that will … technologically advanced elevators that consume less power, satisfy our customers with high levels of have minimal impact on the global environment and harmoniously serve people comfort, efficiency, ecology and safety. and buildings with smooth, seamless operation. The refined design produces a high-quality atmosphere that reassures passengers of the superior safety and comfort synonymous with Mitsubishi Electric products. Regardless of the use or purpose, the NEXIEZ is a best-match solution for virtually any elevator installation. Contents Main Features 3-4 Car Designs 5-8 Hall Designs 9-10 Features 11 Electrical Installation 12 Entrance Layout Drawing 13-14 Basic Specifications for Type MR 15-16 Basic Specifications for Type MRL 17-18 Application for Type MR (m/sec) 1.75 NEXIEZ-GPX Type MR 1.0 We strive to be green in all of our business activities. We take every action to reduce environmental burden during each process of our elevators’ and escalators’ lifecycle. 450 700 (kg) 750 Application for Type MRL (m/sec) 1.75 NEXIEZ-GPX Type MRL 1.0 450 1 550 630 825 (kg) 2 Main Features Using Energy Wisely Flexible Elevator Layout Our long-term commitment to developing energy-efficient elevators has created systems and functions that make intelligent use of power. NEXIEZ-GPX comes in two types: configurations with and without machine room (Type MR and Type MRL). Choose the configuration that is better suited for the space and other building conditions. Milestones of Energy-saving Technologies in Elevator Development 1970 Permanent magne I n d u c t i o n m o to r Motor 2010 20 0 0 1990 1980 Motor drive AC2 control Control circuit AC V V *1 control 100% t m o to r V V VF**22 control Relay Power consumption / CO2 emissions*3 Type MRL (MRL: Machine-room-less) G e ar l e ss Worm geared Traction machine Type MR (MR: Machine room) Microcomputer 93% 74% The top machine room, accommodating bulky equipment, allows simple and flexible equipment layout to fit the hoistway into a limited space in the building. 37% 30 % Approx. –70% All equipment is installed in the hoistway. Without the machine room, the space on the hoistway gives architectures and interior designers greater freedom in design. Traction Machine with PM Motor Emergency Situations (PM motor: Permanent magnet motor) Firefighters’ Emergency Operation (FE) (Optional) Fire Emergency Return (FER) (Optional) When the fire operation switch is activated, the car immediately returns to a predetermined floor. The car then responds only to car calls which facilitate firefighting and rescue operations. When a key switch or a building’s fire alarm is activated, all cars immediately return to a specified floor and open the doors to facilitate the safe evacuation of passengers. The joint-lapped core built into the PM motor of the traction machine features flexible joints. The iron core acts like a hinge, which allows coils to be wound around the core more densely, resulting in improved motor efficiency and compactness. A high-density magnetic field is produced, enabling lower use of energy and resources and reduced CO2 emissions. Motor Motor Control panel Control panel Switch LED Lighting Used for ceiling lights, LEDs boost the overall energy performance of the building. Furthermore, a long service life eliminates the need for frequent lamp replacement. To a specified floor Switch Building’s fire alarm or return signal from supervisory room Firefighter Emergency power supply Normal power supply Emergency power supply Normal power supply To a specified floor ● Advantage of LEDs Earthquake Emergency Return (EER-S) (Optional) Ceiling: L500 Service life (hr) LED Incandescent lamp When a secondary wave seismic sensor is activated, all cars stop at the nearest floor and park there with the doors open to facilitate the safe evacuation of passengers. Power consumption (W) 40000 2000 Approximately 20 times longer LED Incandescent lamp 14.4 132 Motor Control panel Switch Approximately 88% reduction Seismic sensor Ceiling: L500 LED downlights Emergency power supply 3 Normal power supply To the nearest floor 4 Car Designs (1/2) L500 N520 Ceiling: Ceiling: [Center] Painted steel sheet (Black) [Sides] Painted steel sheet (White) Lighting: [Center] Fluorescent lamp [Sides] Downlights (LEDs) [Center] Brushed stainless-steel [Sides] Painted steel sheet (Black) Lighting: Downlights (LEDs) Car Design Example Walls Transom panel Doors Front return panels Kickplate Flooring Car operating panel Car Design Example - Brushed stainless-steel - Brushed stainless-steel - Brushed stainless-steel - Brushed stainless-steel - Brushed stainless-steel - 69 - Type LCD Walls - Decorative plastic finish (4745-60) Transom panel - Brushed stainless-steel Doors - Decorative plastic finish (4745-60) Front return panels - Brushed stainless-steel Kickplate - Painted steel sheet Flooring - 602 Car operating panel - Type LCD The ceiling height of the car shown in this design image is 2600mm. N510 N530 Ceiling: [Center] Milky white acrylic panel [Sides] Painted steel sheet (Black) Lighting: [Center] Fluorescent lamp [Sides] Downlights (LEDs) Ceiling: Car Design Example Car Design Example Walls Walls - Decorative plastic finish (7850-60) Transom panel - Brushed stainless-steel Doors - Decorative plastic finish (7850-60) Front return panels - Brushed stainless-steel Kickplate - Brushed stainless-steel Flooring - 618 Car operating panel - Type LED 5 [Center] Brushed stainless-steel [Sides] Painted steel sheet (Black) Lighting: Fluorescent lamp Downlights (LEDs) - Decorative plastic finish (7054-60) Transom panel - Brushed stainless-steel Doors - Decorative plastic finish (7054-60) Front return panels - Brushed stainless-steel Kickplate - Brushed stainless-steel Flooring - 650 Car operating panel - Type LED Actual colors may differ slightly from those shown. 6 Car Designs (2/2) Car Operating Panels Materials and Colors Walls, doors Stainless-steel Buttons accented with LED halo illumination Illuminated characters (CBV1), arrows (PIV1) and halos attract user’s attention. Brushed finish Decorative plastic finish Yellow-orange lighting Illumination color Tactile Stainless-steel with non-directional brushed f inish Code No. All Type MR Type MRL 1863K-55 2047-60-100 4166-60 4744-60 4745-60 4746-60 7054-60 7850-60 Y006 Y010 Y017 Y054 Y120 Y010 Y017 Y054 Y120 Painted finish Configuration Elevator type*1 D403-60 *2 Location of car operating panel Y003 Front return panel P08-2S P11-CO P11-2S Front return panel P06-2S P08-CO Side wall Transom panel Stainless-steel Brushed finish Flooring Painted finish Type LED Type LCD Notes: *1: Appearing fixing method of face plate is slightly different in elevator type. Please consult our local agents for more details. *2: The entrance width (JJ) shall be 800mm. For JJ=900mm, please consult our local agents. 69 Interior 602 612 618 650 651 Y003 Y006 Finishes Application Mirror Walls*1 Handrail Transom panel Doors Front return panel Kickplate YH-59S Flooring Sill YZ-52A 7 Required Color No. Brushed stainless-steel Decorative plastic finish Painted steel sheet Brushed stainless-steel Painted steel sheet Brushed stainless-steel Decorative plastic finish Painted steel sheet Brushed stainless-steel Paint *2 Brushed stainless-steel Durable vinyl tiles (2mm thick) Durable rubber tiles (3 or 6mm thick) Marble (Supplied by customer) Extruded hard aluminum - Please consult our local agents. - Type MR only Notes: - Applicable *1: A half-size mirror on the rear wall is available as an option. *2: Only available in dark gray. 8 Hall Designs E-102 E-302 Narrow Jamb Materials and Colors Splayed Jamb Doors and jamb Stainless-steel Brushed finish Painted finish Y003 Jamb - Painted steel sheet (Y010) Doors - Painted steel sheet (Y010) Hall position indicator and hall button - PIV1-A710 Y006 Y010 Brushed stainless-steel Sill 9 PIV1-C720 PIV1-C760 (Type MRL only) Color No. Painted steel sheet Painted steel sheet Doors Note: Required Brushed stainless-steel Jambs PIV1-C710 Y120 Finishes Application PIV1-A720 Y054 Jamb - Brushed stainless-steel Doors - Brushed stainless-steel Hall position indicator and hall button - PIV1-C710 Hall Position Indicators and Buttons PIV1-A710 Y017 Extruded hard aluminum - Applicable - Please consult our local agents. PIV1-C770 (Type MRL only) 10 Electrical Installation Features Power Feeder Data Operational and Service Features Feature Abbreviation 1C-2BC 2C-2BC Required - Backup Operation for Car Control Microprocessor CCBK Backup Operation for Group Control Microprocessor GCBK Backup Operation for Hall Control Microprocessor HCBK - CCC - Car Call Canceling Car Fan Shut Off – Automatic CFO-A Car Light Shut Off – Automatic CLO-A Continuity of Service COS Elevator remote control – Car Capacity (kg) 450 - 550 - EVRC-C False Call Canceling – Car Button Type 700 FCC-P Independent Service IND - Next Landing NXL - Non-service Temporary Release for Car Call – Card Reader Type Non-service to Specific Floors – Switch for Type MR - - #1 750 Overload Holding Stop OLH - Safe Landing SFL - Capacity (kg) 450 Group Control Features Abbreviation Forced Floor Stop FFS Main Floor Changeover Operation TFS Main Floor Parking 1C-2BC 2C-2BC 825 SOHS - Abbreviation 1C-2BC - Door Operation Features 2C-2BC Required DSAC - Door Load Detector DLD - Door Nudging Feature – With Buzzer NDG - DODA - Multi-beam Door Sensor - - Reopen with Hall Button ROHB - RDC - Automatic Door Speed Control Door Sensor Self-diagnosis Repeated Door-close 630 Required MFP Feature Abbreviation Car Arrival Chime – Car AECC Car LCD Position Indicator CID-S Car Top Buzzer CTBZ Emergency Alarm Bell #3 Hall LCD Position Indicator Type MRL Inter-communication System #3 Voice Guidance System Feature 1C-2BC 2C-2BC 11 1C-2BC (1-car selective collective), 2C-2BC (2-car group control) = Standard = Optional = Not applicable #1: NS for 1C-2BC: Up to 20 stops, NS for 2C-2BC: Up to 16 stops #2: Cannot be combined with ITP, EMB. #3: When ITP is applied, Emergency Alarm Bell is . 2.8 3.7 6.5 5.1 8.9 15 20 33 25 42 FLAcc (A) Capacity of power supply (kVA) Breaker in control panel (A) Heat emissions (W) 25 34 58 44 75 4 5 7 6 9 20 30 40 30 50 740 960 1520 1190 1930 Current at 200V ● When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power supply transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are each multiplied by the corresponding diversity factor below. Abbreviation 1C-2BC 2C-2BC Required EER-S FER Notes: • • • • • FLU (A) 1.0 1.0 1.75 1.0 1.75 700 850 1500 1100 1900 1200 2050 The wire length for the feeder size must be calculated via the following formula. Wire length (m) < = Coefficient* × E (V)/FLAcc (A) (E: power supply voltage (V)) (FLAcc (A): current while accelerating with full load at power supply voltage of 200V) *Refer to the table below for coefficients. - ITP Fire Emergency Return Operation by Emergency Power Source – Automatic only Motor output (kW) 20 30 40 30 40 30 50 1.25 (Note) × FLU (A) (FLU (A): current during upward operation with full load at power supply voltage of 200V) Note: For Type MR, the value is 1.05 for the elevator with the rated capacity 700kg or more and the rated speed 1.75m/sec. Required AAN-G ECL Mitsubishi Emergency Landing Device Rated speed (m/sec) 4 5 7 5 8 6 9 ● The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40°C. - PIM-C Emergency Car Lighting Firefighters’ Emergency Operation 26 31 52 39 65 41 70 Feeder Size Calculation Emergency Operations and Features Earthquake Emergency Return 16 19 30 23 38 24 40 Note: If power supply voltage (E) is a value other than 200V, FLU current and FLAcc current are obtained via the following formula. (FLU/FLAcc current (A) at E (V)) = (Current at 200V) × (200/E (V)) Type MR FLAcc (A) 2.8 3.4 5.9 4.3 7.6 4.6 8.1 Heat emissions (W) FLU: current during upward operation with full load at power supply voltage of 200V. FLAcc: current while accelerating with full load at power supply voltage of 200V. Signal and Display Features Feature FLU (A) 1.0 1.0 1.75 1.0 1.75 1.0 1.75 Capacity of NF size in power supply machine room (A) (kVA) Current at 200V for Type MRL NS HOS Strategic Overall Spotting Motor output (kW) NSCR-C Out-of-service by Hall Key Switch Feature Rated speed (m/sec) No. of elevators/group Diversity factor - 2 2.0 FE MELD OEPS-SA ● The current size of the grounding wire is determined according to the current rating of the NF breaker on the power source side. ● The current rating of the NF breaker on the power source side should be one level larger than that on the receiving box side in the elevator machine room or hoistway. * Feeder size (mm2) Coefficient 3.5 6.3 5.5 9.7 8 13.8 14 23.9 22 35.9 30 46.4 38 57.6 50 71.3 60 85 80 105 100 126 125 146 150 166 200 192 250 218 325 244 12 Entrance Layout Drawing 2S (Side Opening) Entrance width: JJ 150 55 Door elevation (section A-A) E-302 Keyhole Keyhole 300 25 Entrance height: 2100 140 60 30 150 150 Finished Min. 50 wall (by owner) 140 60 Jamb depth: min. 130 20 91 10° Entrance width: JJ JD 10 Entrance height: 2100 35 10 70 50 30 91 30 Sill support (by owner) 91 30 25 5 30 30° 30° 91 Door plan (section B-B) Door elevation (section A-A) E-102 E-302 Keyhole A A Keyhole A 100 100 13 B 150 B Entrance width: JJ 150 1200 1200 Finished floor level A Hoistway entrance Entrance width: JJ 1200 Finished floor level A 150 Entrance height: 2100 Entrance height: 2100 Entrance width: JJ 1200 150 B B Entrance height: 2100 100 Entrance height: 2100 Entrance width: JJ B B B B 100 100 120 120 100 25 A 91 Finish 30° 55 E-102 Wall 300 60 140 30 30° Door plan (section B-B) Sill support (by owner) (Min. clearance) 70 25 140 60 30 150 150 100 150 Finished wall (by owner) 75~113 10 20 90 Entrance width: JJ 100 E-302 Finish Finished wall (by owner) 25 Entrance height: 2100 Entrance height: 2100 30 ° 5 10 38 300 E-302 (Min. clearance) E-102 70 E-102 300 35 70 100 150 Jamb depth: min. 130 55 30 4 30 55 80 Finish (Min. clearance) 30 100 E-302 Sill support (by owner) E-302 4 50 Finished wall (by owner) Entrance width: JJ 10 10 30 55 Wall 38 Finish Sill support (by owner) E-102 55 E-102 (Min. clearance) CO (Center Opening) Finished floor level Finished floor level A A Hoistway entrance 14 Basic Specifications for Type MR Horizontal Dimensions Hoistway Plan Hoistway Section Machine Room Plan 800 *1 1400×1030 2S 800 1100×1400 800 *1 1400×1250 *2 P10 10 700 CO 800 *1 1400×1250 P11 11 750 2S 800 1350×1400 1750×1400 1800×1530 1600×1750 1750×1590 1800×1830 1600×2050 2100×1460 2100×1600 1750×1810 2050×1800 □ □ □ □ □ □ □ □ □ □ 1850×2700 1850×2050 1800×2980 1850×2900 1850×2200 1800×3280 2100×2050 2100×2050 1850×3100 2050×2200 R6 R5 Entrance width: JJ R4 Control panel Lighting outlet (by owner) Car internal width: AA [ Terms of the table] • The contents of this table are applied to standard specifications only. Please consult our local agents for other specifications. • Rated capacity is calculated at 75kg per person, as required by the Building Standard Law of Japan, 2009. • CO: 2-panel center opening doors, 2S: 2-panel side sliding doors. • Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance. • This table shows specifications without the fireproof landing door and counterweight safety. [Notes] *1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local aqents for details. *2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details. R2 Ventilator (by owner) Power-receiving box (by owner) Power outlet (by owner) Shown for CO doors Counterweight rear drop Ceiling height 2300 (standard) CO Rear Side*2 Rear*2 Rear Side*2 Rear*2 Side Side Rear Side Overhead: OH 1100×1100 R3 Entrance height: HH 2100 (standard) 800 R1 Machine room clear height: HM 2200 1400×850 2S Access door Width: 700 Height: 2000 800 *1 Hoistway depth: BH 1.0 1.75 CO Car internal depth: BB 550 8 P8 1.0 450 6 P6 Hoistway width: AH Ventilation grille Machine room depth: BM Machine room clear width: AM Required Machine room clear width: AM Vertical Dimensions R1 4400 4400 4630 4630 1360 1410 2200 2200 2500 2500*1*1 20 JJ Control panel AA [Terms of the table] ・The contents of this table only apply to standard specifications without counterweight safety. Please consult our local agents for other specifications. [Note] *1: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm. R2 Lighting outlet (by owner) Power-receiving box (by owner) Pit depth: PD 60 60 70 70 データ不明 R4 Access door Width: 700 Height: 2000 450, 450, 550, 550, 700, 700, 750 750 550, 550, 700, 700, 750 750 Ventilator (by owner) Ventilation grille Machine room depth: BM BB R5 1.0 1.0 1.75 1.75 BH R6 Power outlet (by owner) Shown for 2S doors Counterweight rear drop Reaction Loads R5 Machine room clear width: AM 450 1100×1100 1.0 1.0 1400×1030 1.75 8 550 1.0 1100×1400 1.75 1.0 10 700 1400×1250 1.75 11 15 750 1350×1400 1.0 1.75 Rear Side Rear Side Rear Side Rear Side Rear Side Rear Side Rear Side Side R2 R3 R4 16 16 14 19 15 17 15 16 15 17 16 19 19 20 21 22 23 21 22 22 24 25 24 26 25 24 25 25 26 26 27 29 29 30 9 9 11 10 12 10 13 9 12 9 13 10 11 11 12 13 13 R5 R6 53 46 R6 R5 61 51 61 52 61 51 61 52 68 56 70 58 77 64 JJ AA Note: Hoistway section for counterweight side drop is slightly different from this figure. R3 R4 R1 R2 Lighting outlet (by owner) Powerreceiving box (by owner) Power outlet (by owner) R6 Machine room depth: BM 6 R1 21 22 20 24 22 25 23 25 22 25 22 26 26 27 28 29 29 Ventilation grille AH BB 1400×850 Reaction loads(kN) BH Counterweight position Floor to floor height R3 Travel: TR AH Control panel Ventilator (by owner) Access door Width: 700 Height: 2000 Shown for 2S doors Counterweight side drop 16 Basic Specifications for Type MRL Horizontal Dimensions Hoistway Plan Hoistway Section Required Hoistway width: AH 800 * 1350×1400 Side □ □ □ □ □ 1500×1740 1800×1720 1650×1800 2025×1720 1900×1800 R4 Car internal width: AA R6 R3 R2 [ Terms of the table] • The contents of this table are applied to standard specifications only. Please consult our local agents for other specifications. • Rated capacity is calculated at 75kg per person, as required by EN81-1. • CO: 2-panel center opening doors, 2S: 2-panel side sliding doors. • Minimum hoistway dimensions (AH and BH) shown in the table are after waterproofing of the pit and do not include plumb tolerance. • This table shows specifications without the fireproof landing door and counterweight safety. [Notes] *1: Entrance width(JJ) of 900mm is also applicable. For minimum hoistway dimensions, etc., please consult our local agents for details. *2: This counterweight position or dimension is not available in some areas. Please consult our local agents for details. Shown for CO doors Counterweight side drop 1.75 825 450, 630, 825 TR < = 30 30 < TR < = 60 TR < = 30 30 < TR < = 60 TR < = 30 30 < TR < = 60 60 < TR < = 70 AH 3850*1 3900*1 3900 3950 4050 4100 4150 1300*1 1350 20 2500*2 R4 1450 1500 1550 R6 [ Terms of the table] • The contents of this table are applied to standard specifications only. Please consult our local agents for other specifications. • This table shows specifications without counterweight safety. [Notes] *1: If the capacity is 630kg and marble (supplied by customer) is selected for flooring finish, the dimension may be changed. Please consult our local agents for details. *2: Some specifications require more than 2500mm as a minimum floor height. Please consult our local agents if the floor height is less than entrance height HH + 700mm. Reaction Loads 450 630 825 950×1300 1100×1400 1350×1400 R3 R2 R5 R1 JJ Reaction loads(kN) 6 8 11 AA Floor to floor height 1.0 R1 Entrance width: JJ Vertical Dimensions 450, 630 R5 1.0 1.0 1.75 Entrance height: HH 2100 (standard) 1100×1400 Ceiling height 2300 (standard) 950×1300 800 * Overhead: OH 825 800 Travel: TR 11 1.0 1.75 2S CO 2S CO 2S R1 R2 R3 R4 R5 R6 31 43 48 22 32 35 23 33 35 18 26 28 61 80 92 52 68 76 Shown for 2S doors Counterweight side drop Pit depth: PD P11 1.0 Hoistway depth: BH 630 BH 450 8 Car internal depth: BB 6 P8 BB P6 R5 17 R6 18 State-of-the-Art Factories… For the Environment. For Product Quality. Mitsubishi Electric elevators and escalators are currently operating in approximately 90 countries around the globe. Built placing priority on safety first, our elevators, escalators and building system products are renowned for their excellent efficiency, energy savings and comfort. The technologies and skills cultivated at the Inazawa Works and 13 overseas manufacturing factories are utilized in a global network that provides sales, installation and maintenance in support of maintaining and improving product quality. As a means of contributing to the realization of a sustainable society, we consciously consider the environment in business operations, proactively work to realize a low-carbon, recycling-based society, and promote the preservation of biodiversity. Certification Mitsubishi Electric de Mexico, S.A. de C.V. has acquired ISO 9001 certification from the International Organization for Standardization based on a review of quality management. The plant has also acquired the certification of INDUSTRIA LIMPIA, based on the audit of corresponding program. Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses the Group’s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society. Visit our website at: http://www.MitsubishiElectric.com/elevator/ New publication effective Oct. 2016. Specifications are subject to change without notice. C-CL1-6-C9896-A INA-1610 Printed in Japan (IP) 2016