Subido por qfberml

uroanalisis y liquidos corporales

Anuncio
3920_FM_i-xv 23/01/14 11:22 AM Page i
Urinalysis
and Body Fluids
SIXTH EDITION
Susan King Strasinger, DA, MLS(ASCP)
Faculty Associate
Clinical Laboratory Sciences Program
The University of West Florida
Pensacola, Florida
Marjorie Schaub Di Lorenzo, BS, MLS(ASCP)SH
Adjunct Instructor
Division of Laboratory Sciences
Clinical Laboratory Science Program
University of Nebraska Medical Center
Omaha, Nebraska
and
Phlebotomy Technician Program Coordinator
Health Professions
Nebraska Methodist College
Omaha, Nebraska
3920_FM_i-xv 23/01/14 11:22 AM Page ii
F. A. Davis Company
1915 Arch Street
Philadelphia, PA 19103
www.fadavis.com
Copyright © 2014 by F. A. Davis Company
Copyright © 2014 by F. A. Davis Company. All rights reserved. This product is protected by copyright. No part of it may be reproduced, stored in a retrieval
system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without written permission from the
publisher.
Printed in the United States of America
Last digit indicates print number: 10 9 8 7 6 5 4 3 2 1
Senior Acquisitions Editor: Christa Fratantoro
Manager of Content Development: George W. Lang
Developmental Editor: Molly Mullen Ward
Art and Design Manager: Carolyn O’Brien
As new scientific information becomes available through basic and clinical research, recommended treatments and drug therapies undergo changes. The author(s)
and publisher have done everything possible to make this book accurate, up to date, and in accord with accepted standards at the time of publication. The
author(s), editors, and publisher are not responsible for errors or omissions or for consequences from application of the book, and make no warranty, expressed
or implied, in regard to the contents of the book. Any practice described in this book should be applied by the reader in accordance with professional standards
of care used in regard to the unique circumstances that may apply in each situation. The reader is advised always to check product information (package inserts)
for changes and new information regarding dose and contraindications before administering any drug. Caution is especially urged when using new or infrequently
ordered drugs.
Library of Congress Cataloging-in-Publication Data
Strasinger, Susan King, author.
Urinalysis and body fluids / Susan King Strasinger, Marjorie Schaub Di Lorenzo. — Sixth edition.
p. ; cm.
Includes bibliographical references and index.
ISBN 978-0-8036-3920-1 (pbk. : alk. paper)
I. Di Lorenzo, Marjorie Schaub, 1953- author. II. Title.
[DNLM: 1. Urinalysis—methods. 2. Body Fluids—chemistry. QY 185]
RB53
616.07’566—dc23
2013021830
Authorization to photocopy items for internal or personal use, or the internal or personal use of specific clients, is granted by F. A. Davis Company for users
registered with the Copyright Clearance Center (CCC) Transactional Reporting Service, provided that the fee of $.25 per copy is paid directly to CCC, 222
Rosewood Drive, Danvers, MA 01923. For those organizations that have been granted a photocopy license by CCC, a separate system of payment has been
arranged. The fee code for users of the Transactional Reporting Service is: 978-0-8036-3920-1/14 0 + $.25.
3920_FM_i-xv 23/01/14 11:22 AM Page iii
To Harry—you will always be my Editor-in-Chief
—SKS
To my husband, Scott; my daughter, Lauren;
my sons, Michael and Christopher;
my daughters-in-law, Kathleen and Ashley;
and my grandsons, Cameron and Joseph.
—MSD
3920_FM_i-xv 23/01/14 11:22 AM Page iv
3920_FM_i-xv 23/01/14 11:22 AM Page v
Preface
As will be apparent to readers, the sixth edition of Urinalysis
and Body Fluids has been substantially revised and enhanced.
However, the objective of the text—to provide concise, comprehensive, and carefully structured instruction in the analysis
of nonblood body fluids—remains the same.
This sixth edition has been redesigned to meet the changes
occurring in both laboratory medicine and instructional
methodology.
To meet the expanding technical information required by
students in laboratory medicine, all of the chapters have been
updated. Chapter 1 covers overall laboratory safety, precautions
relating to urine and body fluid analysis, and the importance of
quality assessment and management in the urinalysis laboratory.
Preexamination, examination, and postexamination variables,
procedure manuals, and current regulatory issues are stressed.
Chapter 6 includes numerous additional images showing
the various urine microscopic components. In Chapters 7 and
8 the most frequently encountered diseases of glomerular,
tubular, interstitial, vascular, and hereditary origin are related
to their associated laboratory tests. To accommodate advances
in laboratory testing of cerebrospinal, seminal, synovial, serous,
and amniotic fluids, all of the individual chapters have been
enhanced, and additional anatomy and physiology sections
have been added for each of these fluids. An entirely new chapter
(Chapter 15) dedicated to vaginal secretions and covering
proper specimen collection and handling, diseases, and related
diagnosis laboratory tests has been added.
Appendix A provides coverage of the ever-increasing
variety of automated instrumentation available to the urinalysis
laboratory. Appendix B discusses the analysis of bronchoalveolar
lavage specimens, an area of the clinical laboratory that has
been expanding in recent years.
Each chapter opens with objectives and key terms and
concludes with multiple choice questions for student review.
In response to readers’ suggestions, the number of color images
and figures has been significantly increased. The text has been
extensively supplemented with tables, summaries, and procedure boxes. Case studies in the traditional format and clinical
situations relating to technical considerations included at the
end of the chapters offer students an opportunity to think critically about the material. A new feature, Historical Notes, provides a reference for topics or tests that are no longer routinely
performed. Another new feature, Technical Tips, emphasizes
information important to performing procedures. An answer
key for the study questions, case studies, and clinical situations
is included at the end of the book. Key terms appear in boldface blue color within the chapters. General medical terms
appear in boldface in the text and are also included in the
Glossary. The abbreviations noted in boldface red color have
been collected in a convenient Abbreviations list at the back
of the book. An electronic test bank, chapter-by-chapter PowerPoints, a searchable digital version of the textbook, resources
for instructors, and interactive exercises and animations for
students are provided on the DavisPlus Web site.
We thank our readers for their valuable suggestions, which
have guided us in creating this exciting new edition and the
electronic ancillary supports.
Susan King Strasinger
Marjorie Schaub Di Lorenzo
v
3920_FM_i-xv 23/01/14 11:22 AM Page vi
3920_FM_i-xv 23/01/14 11:22 AM Page vii
Reviewers
Lorraine Doucette, MS, MLS(ASCP)CM
Associate Professor and Medical Laboratory Technician Program Coordinator
Anne Arundel Community College
Arnold, Maryland
Pamela B. Lonergan, MS, MT(ASCP)SC
Medical Technology Program Director
Department of Nursing and Allied Health
Norfolk State University
Norfolk, Virginia
Jessica Loontjer, MLS(ASCP)CM, LS(ASCP)CM
Clinical Instructor, Special Chemistry and Urinalysis/Body Fluids
Nebraska Methodist Hospital Laboratory
Omaha, Nebraska
Michelle Moy, MAd Ed, MT(ASCP)SC
Program Director
Clinical Laboratory Science Program
Loyola University
Chicago, Illinois
C. Thomas Somma, PhD
Associate Professor
School of Medical Diagnostics and Translational Sciences
College of Health Sciences
Old Dominion University
Norfolk, Virginia
vii
3920_FM_i-xv 23/01/14 11:22 AM Page viii
3920_FM_i-xv 23/01/14 11:22 AM Page ix
Acknowledgments
Many people deserve credit for the help and encouragement
they have provided us in the preparation of this sixth edition.
Our continued appreciation is also extended to all of the
people who were instrumental in the preparation of previous
editions.
The valuable suggestions from previous readers and the
support from our colleagues at the University of West Florida,
Northern Virginia Community College, University of Nebraska
Medical Center, and Methodist Hospital have been a great asset
to us in the production of this new edition. We thank each and
every one of you. Brenda Franks has provided us with many
valuable documents for reference in this text. The authors thank
and acknowledge Pamela S. Hilke, MS, CT(ASCP), Education
Coordinator and Instructor, and Sophie K. Thompson, MHS,
CT, (ASCP) (IAC), Program Director and Associate Professor of
the Cytotechnology Program at the School of Medical Diagnostic and Translational Sciences, College of Health Sciences, Old
Dominion University, Norfolk, Virginia, for their contributions
of spectacular cytology images.
We extend special thanks to the people who have provided us with so many beautiful photographs for the text
over the years: Donna L. Canterbury, BA, MT(ASCP)SH;
Joanne M. Davis, BS, MT(ASCP)SH; M. Paula Neumann,
MD; Gregory J. Swedo, MD; and Scott Di Lorenzo, DDS.
We also thank Sherman Bonomelli, MS, for contributing
original visual concepts that became the foundation for many
of the line illustrations, and the students from the University
of West Florida, specifically Jennifer Cardenas, Shannel
Hill, Jelma Moore, and William Laguer, who worked under
the guidance of Sherman Bonomelli to produce many of
the new images. Images for Chapter 14 were provided by
Carol Brennan, MT(ASCP), Diane Siedlik, MT(ASCP), Christian Herdt, MT(ASCP), and Teresa Karre, MD, from Methodist
Hospital.
We would like to express our gratitude for the help, patience,
guidance, and understanding of our editors at F. A. Davis: Christa
Fratantoro, Senior Acquisitions Editor; George Lang, Manager of
Content Development, Health Professions/Medicine; and Molly
M. Ward, Development Editor. We thank all the members of the
F. A. Davis team who were instrumental in bringing this edition
to fruition: Elizabeth Stepchin, Alisa Hathaway, Carolyn O’Brien,
and Sharon Lee.
ix
3920_FM_i-xv 23/01/14 11:22 AM Page x
3920_FM_i-xv 23/01/14 11:22 AM Page xi
Contents
PART ONE:
Background
CHAPTER 1
Safety and Quality Assessment 3
SAFETY 4
Biologic Hazards 4
Personal Protective Equipment 7
Hand Hygiene 7
Biologic Waste Disposal 9
Sharp Hazards 9
Chemical Hazards 10
Chemical Spills and Exposure 10
Chemical Handling 10
Chemical Hygiene Plan 10
Chemical Labeling 10
Material Safety Data Sheets 10
Radioactive Hazards 11
Electrical Hazards 11
Fire/Explosive Hazards 12
Physical Hazards 13
QUALITY ASSESSMENT 13
Urinalysis Procedure Manual 14
Preexamination Variables 14
Examination Variables 16
Postexamination Variables 20
CHAPTER 2
Introduction to Urinalysis 27
History and Importance 28
Urine Formation 29
Urine Composition 29
Urine Volume 29
Specimen Collection 30
Containers 30
Labels 30
Requisitions 31
Specimen Rejection 31
Specimen Handling 31
Specimen Integrity 31
Specimen Preservation 31
Types of Specimens 32
Random Specimen 32
First Morning Specimen 33
24-Hour (or Timed) Specimen 33
Catheterized Specimen 34
Midstream Clean-Catch Specimen 34
Suprapubic Aspiration 34
Prostatitis Specimen 34
Pediatric Specimens 34
Drug Specimen Collection 35
CHAPTER 3
Renal Function 39
Renal Physiology 40
Renal Blood Flow 40
Glomerular Filtration 41
Tubular Reabsorption 43
Tubular Secretion 45
Renal Function Tests 46
Glomerular Filtration Tests 47
Cystatin C 49
Tubular Reabsorption Tests 50
Tubular Secretion and Renal Blood Flow Tests 52
PART TWO:
Urinalysis
CHAPTER 4
Physical Examination of Urine 59
Color 60
Normal Urine Color 60
Abnormal Urine Color 61
Clarity 62
Normal Clarity 62
Nonpathologic Turbidity 63
Pathologic Turbidity 63
Specific Gravity 63
Refractometer 64
Osmolality 65
Reagent Strip Specific Gravity 66
Odor 66
CHAPTER 5
Chemical Examination of Urine 71
Reagent Strips 72
Reagent Strip Technique 72
Handling and Storing Reagent Strips 73
Quality Control of Reagent Strips 73
Confirmatory Testing 73
pH 73
Clinical Significance 73
Reagent Strip Reactions 75
Protein 75
Clinical Significance 75
Prerenal Proteinuria 75
xi
3920_FM_i-xv 23/01/14 11:22 AM Page xii
xii
Contents
Renal Proteinuria 76
Postrenal Proteinuria 76
Reagent Strip Reactions 77
Reaction Interference 77
Glucose 79
Clinical Significance 79
Reagent Strip (Glucose Oxidase) Reaction 81
Reaction Interference 81
Copper Reduction Test (Clinitest) 81
Clinical Significance of Clinitest 82
Ketones 82
Clinical Significance 82
Reagent Strip Reactions 83
Reaction Interference 83
Blood 83
Clinical Significance 84
Hematuria 84
Hemoglobinuria 84
Myoglobinuria 84
Reagent Strip Reactions 84
Reaction Interference 85
Bilirubin 85
Bilirubin Production 85
Clinical Significance 86
Reagent Strip (Diazo) Reactions 87
Reaction Interference 87
Urobilinogen 87
Clinical Significance 88
Reagent Strip Reactions and Interference 88
Reaction Interference 88
Nitrite 88
Clinical Significance 88
Reagent Strip Reactions 89
Reaction Interference 89
Leukocyte Esterase 90
Clinical Significance 90
Reagent Strip Reaction 90
Reaction Interference 91
Specific Gravity 91
Reagent Strip Reaction 91
Reaction Interference 92
CHAPTER 6
CHAPTER 7
Renal Disease 147
Glomerular Disorders 148
Glomerulonephritis 148
Nephrotic Syndrome 149
Tubular Disorders 150
Acute Tubular Necrosis 150
Hereditary and Metabolic Tubular Disorders
Interstitial Disorders 154
Acute Pyelonephritis 155
Chronic Pyelonephritis 155
Acute Interstitial Nephritis 155
Renal Failure 155
Renal Lithiasis 157
Urine Screening for Metabolic Disorders 163
Overflow Versus Renal Disorders 164
Newborn Screening Tests 164
Amino Acid Disorders 165
Phenylalanine-Tyrosine Disorders 165
Branched-Chain Amino Acid Disorders 167
Tryptophan Disorders 168
Cystine Disorders 169
PART THREE:
Other Body Fluids
CHAPTER 9
Cerebrospinal Fluid 181
101
153
CHAPTER 8
Porphyrin Disorders 170
Mucopolysaccharide Disorders 172
Purine Disorders 174
Carbohydrate Disorders 174
Microscopic Examination of Urine 99
Macroscopic Screening 100
Specimen Preparation 100
Specimen Volume 100
Centrifugation 100
Sediment Preparation 101
Volume of Sediment Examined 101
Commercial Systems 101
Examining the Sediment 101
Reporting the Microscopic Examination
Correlating Results 102
Sediment Examination Techniques 102
Sediment Stains 103
Cytodiagnostic Urine Testing 105
Microscopy 105
Types of Microscopy 107
Urine Sediment Constituents 110
Red Blood Cells 110
White Blood Cells 112
Epithelial Cells 113
Bacteria 118
Yeast 119
Parasites 119
Spermatozoa 120
Mucus 120
Casts 121
Urinary Crystals 128
Urinary Sediment Artifacts 138
Formation and Physiology 182
Specimen Collection and Handling 182
3920_FM_i-xv 23/01/14 11:22 AM Page xiii
Contents
Appearance 183
Traumatic Collection (Tap) 184
Uneven Blood Distribution 184
Clot Formation 184
Xanthochromic Supernatant 185
Cell Count 185
Methodology 185
Total Cell Count 186
WBC Count 186
Quality Control of CSF and Other Body Fluid Cell
Counts 186
Differential Count on a CSF Specimen 186
Cytocentrifugation 186
CSF Cellular Constituents 187
Chemistry Tests 193
Cerebrospinal Protein 193
CSF Glucose 196
CSF Lactate 195
CSF Glutamine 195
Microbiology Tests 195
Gram Stain 196
Serologic Testing 197
CHAPTER 10
Semen 203
Physiology 204
Specimen Collection 205
Specimen Handling 205
Semen Analysis 205
Appearance 205
Liquefaction 206
Volume 206
Viscosity 206
pH 207
Sperm Concentration and Sperm Count 207
Sperm Motility 208
Sperm Morphology 209
Additional Testing 210
Sperm Vitality 211
Seminal Fluid Fructose 211
Antisperm Antibodies 212
Microbial and Chemical Testing 212
Postvasectomy Semen Analysis 213
Sperm Function Tests 213
Semen Analysis Quality Control 213
CHAPTER 11
Synovial Fluid 217
Physiology 218
Specimen Collection and Handling 218
Color and Clarity 219
Viscosity 219
Cell Counts 220
Differential Count 220
Crystal Identification 221
Types of Crystals 221
Slide Preparation 222
Crystal Polarization 222
Chemistry Tests 224
Microbiologic Tests 224
Serologic Tests 224
CHAPTER 12
Serous Fluid 229
Formation 230
Specimen Collection and Handling 230
Transudates and Exudates 231
General Laboratory Procedures 231
Pleural Fluid 232
Appearance 232
Hematology Tests 232
Chemistry Tests 235
Microbiologic and Serologic Tests 236
Pericardial Fluid 236
Appearance 237
Laboratory Tests 237
Peritoneal Fluid 237
Transudates Versus Exudates 237
Appearance 238
Laboratory Tests 238
CHAPTER 13
Amniotic Fluid 243
Physiology 244
Function 244
Volume 244
Chemical Composition 244
Differentiating Maternal Urine From Amniotic
Fluid 245
Specimen Collection 245
Indications for Amniocentesis 245
Collection 246
Specimen Handling and Processing 246
Color and Appearance 246
Tests for Fetal Distress 246
Hemolytic Disease of the Newborn 246
Neural Tube Defects 247
Tests for Fetal Maturity 248
Fetal Lung Maturity 248
Lecithin-Sphingomyelin Ratio 248
Phosphatidyl Glycerol 249
Foam Stability Index 249
Lamellar Bodies 249
xiii
3920_FM_i-xv 23/01/14 11:22 AM Page xiv
xiv
Contents
CHAPTER 14
Fecal Analysis
255
Physiology 256
Diarrhea and Steatorrhea 257
Diarrhea 257
Steatorrhea 258
Specimen Collection 258
Macroscopic Screening 258
Color 258
Appearance 259
Microscopic Examination of Feces 259
Fecal Leukocytes 259
Muscle Fibers 259
Qualitative Fecal Fats 260
Chemical Testing of Feces 261
Occult Blood 261
Quantitative Fecal Fat Testing 262
APT Test (Fetal Hemoglobin) 263
Fecal Enzymes 264
Carbohydrates 264
CHAPTER 15
Vaginal Secretions 269
Specimen Collection and Handling 270
Color and Appearance 271
Diagnostic Tests 271
pH 271
Microscopic Procedures 272
Vaginal Disorders 277
Bacterial Vaginosis 277
Trichomoniasis 278
Candidiasis 278
Desquamative Inflammatory Vaginitis 279
Atrophic Vaginitis 279
Additional Vaginal Secretion Procedures 279
Fetal Fibronectin Test 279
AmniSure Test 279
Urine and Body Fluid Analysis
Automation 283
APPENDIX B Bronchoalveolar Lavage 293
Answers to Study Questions and Case Studies and
Clinical Situations 297
Abbreviations 305
Glossary 307
APPENDIX
A
Index 315
3920_FM_i-xv 23/01/14 11:22 AM Page xv
3920_Ch01_002-026 23/01/14 9:19 AM Page 2
PART ONE
Background
Chapter 1: Safety and Quality Assessment
Chapter 2: Introduction to Urinalysis
Chapter 3: Renal Function
3920_Ch01_002-026 23/01/14 9:19 AM Page 3
CHAPTER
1
Safety and Quality
Assessment
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
1-1 List the six components of the chain of infection and
the laboratory safety precautions that break the chain.
1-7 Discuss the components and purpose of chemical
hygiene plans and Material Safety Data Sheets.
1-2 State the purpose of the Standard Precautions policy
and describe its guidelines.
1-8 State and interpret the components of the National
Fire Protection Association hazardous material
labeling system.
1-3 State the requirements mandated by the Occupational
Exposure to Blood-Borne Pathogens Compliance
Directive.
1-4 Describe the types of personal protective equipment
that laboratory personnel wear, including when, how,
and why each article is used.
1-5 Correctly perform hand hygiene procedures following
Centers for Disease Control and Prevention (CDC)
guidelines.
1-6 Describe the acceptable methods for handling and
disposing of biologic waste and sharp objects in the
urinalysis laboratory.
1-9 Describe precautions that laboratory personnel should
take with regard to radioactive, electrical, and fire hazards.
1-10 Explain the RACE and PASS actions to be taken when
a fire is discovered.
1-11 Recognize standard hazard warning symbols.
1-12 Define the preexamination, examination, and postexamination components of quality assessment.
1-13 Distinguish between the components of internal
quality control, external quality control, electronic
quality control, and proficiency testing.
KEY TERMS
Accreditation
External quality assessment (EQA)
Postexposure prophylaxis (PEP)
Accuracy
External quality control
Precision
Biohazardous
Fomite
Preexamination variable
Chain of infection
Infection control
Preventive maintenance (PM)
Chemical hygiene plan
Internal quality control
Proficiency testing
Clinical Laboratory Improvement
Amendments (CLIA)
Material Safety Data Sheet (MSDS)
Quality assessment (QA)
Occupational Safety and Health
Administration (OSHA)
Quality control (QC)
Electronic quality control
Personal protective equipment
(PPE)
Reliability
Examination variable
Postexamination variable
Clinical and Laboratory Standards
Institute (CLSI)
Radioisotope
Standard Precautions
Turnaround time (TAT)
3920_Ch01_002-026 23/01/14 9:19 AM Page 4
4
Part One | Background
S A F E T Y
The clinical laboratory contains a variety of safety hazards,
many of which are capable of producing serious injury or lifethreatening disease. To work safely in this environment, laboratory personnel must learn what hazards exist, the basic safety
precautions associated with them, and how to apply the basic
rules of common sense required for everyday safety for
patients, co-workers, and themselves.
As can be seen in Table 1–1, some hazards are unique to
the health-care environment, and others are encountered routinely throughout life. Safety procedure manuals must be readily available in the laboratory that describe the safety policies
mandated by the Centers for Disease Control and Prevention
(CDC) and the Occupational Safety and Health Administration (OSHA), and strict adherence to these guidelines by
laboratory personnel is essential. The manual must be updated
and reviewed annually by the laboratory director. The Clinical
and Laboratory Standards Institute (CLSI) provides the
guidelines for writing these procedures and policies.1-3
Biologic Hazards
The health-care setting provides abundant sources
of potentially harmful microorganisms. These microorganisms are frequently present in the specimens
Table 1–1
Types of Safety Hazards
Type
Source
Possible Injury
Biologic
Infectious
agents
Bacterial, fungal,
viral, or parasitic
infections
Cuts, punctures, or
blood-borne
pathogen exposure
Exposure to toxic,
carcinogenic, or
caustic agents
Radiation exposure
Sharps
Needles, lancets,
broken glass
Chemical
Preservatives and
reagents
Radioactive
Equipment and
radioisotopes
Ungrounded or
wet equipment;
frayed cords
Open flames,
organic
chemicals
Wet floors, heavy
boxes, patients
Electrical
Fire/
explosive
Physical
Burns or shock
Burns or
dismemberment
Falls, sprains, or
strains
From Strasinger, SK, and DiLorenzo, MA: The Phlebotomy Textbook, third
edition, FA Davis, Philadelphia, 2011, p 52, with permission.
received in the clinical laboratory. Understanding how microorganisms are transmitted (chain of infection) is essential to
preventing infection. All health-care facilities have developed
procedures to control and monitor infections occurring within
their facilities. This is referred to as infection control. The
chain of infection requires a continuous link between an infectious agent, a reservoir, a portal of exit, a means of transmission, a portal of entry, and a susceptible host.4 Infectious
agents consist of bacteria, fungi, parasites, and viruses. The
reservoir is the location of potentially harmful microorganisms,
such as a contaminated clinical specimen or an infected
patient. It is the place where the infectious agent can live and
possible multiply. Humans and animals make excellent reservoirs. Equipment and other soiled inanimate objects, called
fomites, will serve as reservoirs, particularly if they contain
blood, urine, or other body fluids. Some microorganisms form
spores or become inactive when conditions are not ideal and
wait until a suitable reservoir is available. The infectious agent
must have a way to exit the reservoir to continue the chain
of infection. This can be through the mucous membranes of
the nose, mouth, and eyes, and in blood or other body fluids.
Once the infectious agent has left the reservoir, it must have
a way to reach a susceptible host. Means of transmission include:
1. Direct contact: the unprotected host touches the patient,
specimen, or a contaminated object (reservoir)
2. Airborne: inhalation of dried aerosol particles circulating
on air currents or attached to dust particles
3. Droplet: the host inhales material from the reservoir (e.g.,
aerosol droplets from a patient or an uncapped centrifuge
tube, or when specimens are aliquoted or spilled)
4. Vehicle: ingestion of a contaminated substance (e.g., food,
water, specimen)
5. Vector: from an animal or insect bite
After the infectious agent has been transmitted to a new
reservoir, it must have a means to enter the reservoir. The portal of entry can be the same as the portal of exit, which includes
the mucous membranes of the nose, mouth, and eyes, breaks
in the skin, and open wounds. The susceptible host can be another patient during invasive procedures, visitors, and healthcare personnel when exposed to infectious specimens or
needlestick injuries. Immunocompromised patients, newborns
and infants, and the elderly are often more susceptible hosts.
Stress, fatigue, and lack of proper nutrition depress the immune system and contribute to the susceptibility of patients
and health-care providers. Once the chain of infection is complete, the infected host then becomes another source able to
transmit the microorganisms to others.1
In the clinical laboratory, the most direct contact with a
source of infection is through contact with patient specimens, although contact with patients and infected objects also occurs.
Preventing completion of the chain of infection is a primary objective of biologic safety. Figure 1–1 illustrates the universal symbol for biohazardous material and demonstrates how following
prescribed safety practices can break the chain of infection.
Figure 1–1 places particular emphasis on laboratory practices.
3920_Ch01_002-026 23/01/14 9:19 AM Page 5
Chapter 1 | Safety and Quality Assessment
Break the link
• Immunizations
• Patient isolation
• Nursery
precautions
• Healthy lifestyle
Susceptible
host
• Patients
• Elderly
• Newborns
• Immunocompromised
• Health-care
workers
Break the link
• Disinfection
• Hand hygiene
Infectious agent
• Bacteria
• Fungi
• Parasites
• Viruses
Reservoir
• Humans
• Animals
• Insects
• Fomites
• Blood/body
fluids
Portal of exit
• Nose
• Mouth
• Mucous
membranes
• Specimen
collection
Portal of
entry
• Nose
• Mouth
• Mucous
membranes
• Skin
• Unsterile
equipment
Break the link
• Hand hygiene
• Standard precautions
• PPE
• Sterile equipment
5
Means of transmission
• Droplet
• Airborne
• Contact
• Vector
• Vehicle
Break the link
• Sealed biohazardous
waste containers
• Sealed specimen
containers
• Hand hygiene
• Standard precautions
Break the link
• Hand hygiene
• Standard precautions
• PPE
• Patient isolation
Figure 1–1 Chain of infection and safety practices related to the biohazard symbol. (From Strasinger, SK, and DiLorenzo, MA: The Phlebotomy
Textbook, FA Davis, Philadelphia, 2011, with permission.)
Proper hand hygiene, correct disposal of contaminated
materials, and wearing personal protective equipment (PPE)
are of major importance in the laboratory. Concern over exposure to blood-borne pathogens, such as hepatitis B virus
(HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV), resulted in the drafting of guidelines and
regulations by the CDC and OSHA to prevent exposure. In
1987 the CDC instituted Universal Precautions (UP). Under
UP all patients are considered to be possible carriers of bloodborne pathogens. The guideline recommends wearing gloves
when collecting or handling blood and body fluids contaminated with blood and wearing face shields when there is danger
of blood splashing on mucous membranes and when disposing
of all needles and sharp objects in puncture-resistant containers. The CDC excluded urine and body fluids not visibly
contaminated by blood from UP, although many specimens can
contain a considerable amount of blood before it becomes visible. The modification of UP for body substance isolation
(BSI) helped to alleviate this concern. BSI guidelines are not
limited to blood-borne pathogens; they consider all body
fluids and moist body substances to be potentially infectious.
According to BSI guidelines, personnel should wear gloves at
all times when encountering moist body substances. A major
disadvantage of BSI guidelines is that they do not recommend
handwashing after removing gloves unless visual contamination is present.
3920_Ch01_002-026 23/01/14 9:19 AM Page 6
6
Part One | Background
In 1996 the CDC and the Healthcare Infection Control
Practices Advisory Committee (HICPAC) combined the major
features of UP and BSI guidelines and called the new guidelines
Standard Precautions. Although Standard Precautions, as
described below, stress patient contact, the principles can also
be applied to handling patient specimens in the laboratory.5
Standard Precautions are as follows:
1. Hand hygiene: Hand hygiene includes both hand
washing and the use of alcohol-based antiseptic
cleansers. Sanitize hands after touching blood, body
fluids, secretions, excretions, and contaminated items,
whether or not gloves are worn. Sanitize hands immediately after gloves are removed, between patient contacts,
and when otherwise indicated to avoid transferring
microorganisms to other patients or environments.
Sanitizing hands may be necessary between tasks
and procedures on the same patient to prevent crosscontamination of different body sites.
2. Gloves: Wear gloves (clean, nonsterile gloves are adequate) when touching blood, body fluids, secretions,
excretions, and contaminated items. Put on gloves just
before touching mucous membranes and nonintact
skin. Change gloves between tasks and procedures on
the same patient after contact with material that may
contain a high concentration of microorganisms. Remove gloves promptly after use, before touching noncontaminated items and environmental surfaces, and
between patients. Always sanitize your hands immediately after glove removal to avoid transferring microorganisms to other patients or environments.
3. Mouth, nose, and eye protection: Wear a mask and
eye protection or a face shield to protect mucous membranes of the eyes, nose, and mouth during procedures
and patient care activities that are likely to generate
splashes or sprays of blood, body fluids, secretions, or
excretions. A specially fitted respirator (N95) must be
used during patient care activities related to suspected
mycobacterium exposure.
4. Gown: Wear a gown (a clean, nonsterile gown is adequate) to protect skin and to prevent soiling of clothing
during procedures and patient care activities that are
likely to generate splashes or sprays of blood, body
fluids, secretions, or excretions. Select a gown that is
appropriate for the activity and the amount of fluid
likely to be encountered (e.g., fluid-resistant in the
laboratory). Remove a soiled gown as promptly as
possible, and sanitize hands to avoid transferring
microorganisms to other patients or environments.
5. Patient care equipment: Handle used patient care
equipment soiled with blood, body fluids, secretions,
and excretions in a manner that prevents skin and mucous membrane exposure, clothing contamination, and
transfer of microorganisms to other patients or environments. Ensure that reusable equipment is not used for
the care of another patient until it has been cleaned
and reprocessed appropriately. Ensure that single-use
items are discarded properly.
6. Environmental control: Ensure that the hospital has
adequate procedures for the routine care, cleaning, and
disinfection of environmental surfaces, beds, bedrails,
bedside equipment, and other frequently touched surfaces. Ensure that these procedures are being followed.
7. Linen: Handle, transport, and process linen soiled with
blood, body fluids, secretions, and excretions in a manner that prevents skin and mucous membrane exposures
and clothing contamination and that avoids the transfer
of microorganisms to other patients and environments.
8. Occupational health and blood-borne pathogens:
Take care to prevent injuries when using needles,
scalpels, and other sharp instruments or devices; when
handling sharp instruments after procedures; when
cleaning used instruments; and when disposing of used
needles. Never recap used needles or otherwise manipulate them using both hands or use any other technique
that involves directing the point of a needle toward any
part of the body; rather, use self-sheathing needles or a
mechanical device to conceal the needle. Do not remove
used unsheathed needles from disposable syringes by
hand, and do not bend, break, or otherwise manipulate
used needles by hand. Place used disposable syringes
and needles, scalpel blades, and other sharp items in
appropriate puncture-resistant containers, which are located as close as practical to the area in which the items
were used, and place reusable syringes and needles in a
puncture-resistant container for transport to the reprocessing area. Use mouthpieces, resuscitation bags, or
other ventilation devices as an alternative to mouthto-mouth resuscitation methods in areas where the need
for resuscitation is predictable.
9. Patient placement: Place a patient in a private room
who contaminates the environment or who does not (or
cannot be expected to) assist in maintaining appropriate
hygiene or environment control. If a private room is not
available, consult with infection control professionals
regarding patient placement or other alternatives.
10. Respiratory hygiene/cough etiquette: Educate
health-care personnel, patients, and visitors to contain
respiratory secretions to prevent droplet and fomite
transmission of respiratory pathogens. Offer masks to
coughing patients, distance symptomatic patients from
others, and practice good hand hygiene to prevent the
transmission of respiratory pathogens.
The Occupational Exposure to Blood-Borne Pathogens
Standard is a law monitored and enforced by OSHA.6,7 These
controls are required by OSHA to be provided by or mandated
by the employer for all employees. Specific requirements of
this OSHA standard include the following:
Engineering Controls
1. Providing sharps disposal containers and needles with
safety devices.
3920_Ch01_002-026 23/01/14 9:19 AM Page 7
Chapter 1 | Safety and Quality Assessment
2. Requiring discarding of needles with the safety device
activated and the holder attached.
3. Labeling all biohazardous materials and containers.
Work Practice Controls
4. Requiring all employees to practice Standard Precautions and documenting training on an annual basis.
5. Prohibiting eating, drinking, smoking, and applying
cosmetics in the work area.
6. Establishing a daily work surface disinfection protocol.
Personal Protective Equipment
7. Providing laboratory coats, gowns, face shields, and
gloves to employees and laundry facilities for nondisposable protective clothing.
Medical
8. Providing immunization for the hepatitis B virus free of
charge.
9. Providing medical follow-up to employees who have
been accidentally exposed to blood-borne pathogens.
Documentation
10. Documenting annual training of employees in safety
standards.
11. Documenting evaluations and implementation of safer
needle devices.
12. Involving employees in the selection and evaluation of
new devices and maintaining a list of those employees
and the evaluations.
13. Maintaining a sharps injury log including the type and
brand of safety device, location and description of the
incident, and confidential employee follow-up.
Any accidental exposure to a possible blood-borne
pathogen must be immediately reported to a supervisor. Evaluation of the incident must begin right away to ensure appropriate
postexposure prophylaxis (PEP). The CDC provides periodically updated guidelines for the management of exposures and
recommended PEP.8,9
Personal Protective Equipment
PPE used in the laboratory includes gloves, fluid-resistant
gowns, eye and face shields, and Plexiglas countertop shields.
Gloves should be worn when in contact with patients, specimens, and laboratory equipment or fixtures. When specimens
are collected, gloves must be changed between every patient.
In the laboratory, they are changed whenever they become noticeably contaminated or damaged and are always removed
when leaving the work area. Wearing gloves is not a substitute
for hand hygiene, and hands must be sanitized after gloves are
removed.
A variety of gloves types are available, including sterile and
nonsterile, powdered and unpowdered, and latex and nonlatex.
Allergy to latex is increasing among health-care workers, and
laboratory personnel should be alert for symptoms of reactions
associated with latex. Reactions to latex include irritant contact
7
dermatitis, which produces patches of dry, itchy irritation on
the hands; delayed hypersensitivity reactions resembling poison
ivy that appear 24 to 48 hours after exposure; and true, immediate hypersensitivity reactions often characterized by facial
flushing and breathing difficulties. Hand sanitizing immediately
after removing gloves and avoiding powdered gloves may aid
in preventing the development of latex allergies. Replacing latex
gloves with nitrile or vinyl gloves provides an alternative. Any
symptoms of latex allergy should be reported to a supervisor
because true latex allergy can be life-threatening.10
Fluid-resistant laboratory coats with wrist cuffs are worn
to protect clothing and skin from exposure to patients’ body
substances. These coats should always be completely buttoned,
and gloves should be pulled over the cuffs. They are worn at
all times when working with patient specimens and are removed prior to leaving the work area. They are changed when
they become visibly soiled. Disposable coats are placed in containers for biohazardous waste, and nondisposable coats are
placed in designated laundry receptacles. Shoes must be
closed-toed and cover the entire foot.
The mucous membranes of the eyes, nose, and mouth
must be protected from specimen splashes and aerosols. A variety of protective equipment is available, including masks and
goggles, full-face plastic shields that cover the front and sides
of the face, mask with attached shield, and Plexiglas countertop
shields. Particular care should be taken to avoid splashes and
aerosols when removing container tops, pouring specimens,
and centrifuging specimens. Specimens must never be centrifuged in uncapped tubes or in uncovered centrifuges. When
specimens are received in containers with contaminated exteriors, the exterior of the container must be disinfected or, if
necessary, a new specimen may be requested.
Hand Hygiene
Hand hygiene is emphasized in Figure 1–1 and in the Standard
Precautions guidelines. Hand contact is the primary method
of infection transmission. Laboratory personnel must always
sanitize hands before patient contact, after gloves are removed,
before leaving the work area, at any time when hands have
been knowingly contaminated, before going to designated
break areas, and before and after using bathroom facilities.
Hand hygiene includes both hand washing and using alcoholbased antiseptic cleansers. Alcohol-based cleansers can be used
when hands are not visibly contaminated. They are not recommended after contact with spore-forming bacteria, including
Clostridium difficile and Bacillus sp.
When using alcohol-based cleansers, apply the cleanser to
the palm of one hand. Rub your hands together and over the
entire cleansing area, including between the fingers and
thumbs. Continue rubbing until the alcohol dries.
The CDC has developed hand washing guidelines to
be followed for correct hand washing.1,11 Procedure 1-1
demonstrates CDC routine hand washing guidelines.4 More
stringent procedures are used in surgery and in areas with
highly susceptible patients, such as immunocompromised and
burn patients.
3920_Ch01_002-026 23/01/14 9:20 AM Page 8
8
Part One | Background
PROCEDURE 1-1
Hand Washing Procedure
Equipment
Antimicrobial soap
Paper towels
Running water
Waste container
Procedure
1. Wet hands with warm water. Do not allow parts of
body to touch the sink.
3. Rub to form a lather, create friction, and loosen debris.
Thoroughly clean between the fingers and under the
fingernails for at least 20 seconds; include thumbs and
wrists in the cleaning.
4. Rinse hands in a downward position to prevent
recontamination of hands and wrists.
2. Apply soap, preferably antimicrobial.
5. Obtain paper towel from the dispenser.
3920_Ch01_002-026 23/01/14 9:20 AM Page 9
Chapter 1 | Safety and Quality Assessment
9
PROCEDURE 1-1—cont’d
6. Dry hands with paper towel.
7. Turn off faucets with a clean paper towel to prevent
contamination.
Biologic Waste Disposal
All biologic waste, except urine, must be placed in appropriate
containers labeled with the biohazard symbol (Fig. 1–2). This
includes both specimens and the materials with which the
specimens come in contact. The waste is then decontaminated
following institutional policy: incineration, autoclaving, or
pickup by a certified hazardous waste company.
Urine may be discarded by pouring it into a laboratory
sink under a Plexiglas countertop shield. Care must be taken
to avoid splashing, and the sink should be flushed with water
after specimens are discarded. Disinfection of the sink using a
1:5 or 1:10 dilution of sodium hypochlorite should be performed daily. Sodium hypochlorite dilutions stored in plastic
bottles are effective for 1 month if protected from light after
preparation.12 The same solution also can be used for routinely
disinfecting countertops and accidental spills. The solution
should be allowed to air-dry on the contaminated area. Absorbent materials used for cleaning countertops and removing
spills must be discarded in biohazard containers. Empty
urine containers can be discarded as nonbiologically hazardous
waste (Fig. 1–3).
Sharp Hazards
Sharp objects in the laboratory, including needles,
lancets, and broken glassware, present a serious biologic hazard, particularly for the transmission of
blood-borne pathogens. All sharp objects must be
disposed in puncture-resistant, leak-proof container with the
biohazard symbol. Puncture-resistant containers should be
conveniently located within the work area. The biohazard
sharp containers should not be overfilled and must always be
replaced when the safe capacity mark is reached.
Figure 1–2 Biohazard symbol. (From Strasinger, SK, and DiLorenzo,
MA: The Phlebotomy Textbook, FA Davis, Philadelphia, 2011, with
permission.)
3920_Ch01_002-026 23/01/14 9:20 AM Page 10
10
Part One | Background
removed as soon as possible. No attempt should be made to
neutralize chemicals that come in contact with the skin. Chemical spill kits containing protective apparel, nonreactive
absorbent material, and bags for disposing of contaminated
materials should be available for cleaning up spills.
Chemical Handling
Chemicals should never be mixed together unless specific instructions are followed, and they must be added in the order
specified. This is particularly important when combining acid
and water. Acid should always be added to water to avoid the
possibility of sudden splashing caused by the rapid generation
of heat in some chemical reactions. Wearing goggles and
preparing reagents under a fume hood are recommended safety
precautions. Chemicals should be used from containers that
are of an easily manageable size. Pipetting by mouth is unacceptable in the laboratory. State and federal regulations are in
place for the disposal of chemicals and should be consulted.
A
Chemical Hygiene Plan
OSHA also requires all facilities that use hazardous chemicals
to have a written chemical hygiene plan (CHP) available to
employees.13 The purpose of the plan is to detail the following:
1. Appropriate work practices
2. Standard operating procedures
3. PPE
4. Engineering controls, such as fume hoods and flammables safety cabinets
5. Employee training requirements
6. Medical consultation guidelines
Each facility must appoint a chemical hygiene officer, who
is responsible for implementing and documenting compliance
with the plan. Examples of required safety equipment and
information are shown in Figure 1–4.
B
Figure 1–3 Technologist disposing of urine (A) sample and (B)
container.
Chemical Hazards
The same general rules for handling biohazardous
materials apply to chemically hazardous materials;
that is, to avoid getting these materials in or on bodies, clothes, or work area. Every chemical in the workplace
should be presumed hazardous.
Chemical Spills and Exposure
When skin contact occurs, the best first aid is to flush the area
with large amounts of water for at least 15 minutes, then seek
medical attention. For this reason, all laboratory personnel
should know the location and proper use of emergency showers and eye wash stations. Contaminated clothing should be
Chemical Labeling
Hazardous chemicals should be labeled with a description of
their particular hazard, such as poisonous, corrosive, flammable, explosive, teratogenic, or carcinogenic (Fig. 1–5). The
National Fire Protection Association (NFPA) has developed the
Standard System for the Identification of the Fire Hazards of
Materials, NFPA 704.14 This symbol system is used to inform
firefighters of the hazards they may encounter with fires in
a particular area. The diamond-shaped, color-coded symbol
contains information relating to health, flammability, reactivity,
and personal protection/special precautions. Each category is
graded on a scale of 0 to 4, based on the extent of concern.
These symbols are placed on doors, cabinets, and containers.
An example of this system is shown in Figure 1–6.
Material Safety Data Sheets
The OSHA Federal Hazard Communication Standard requires
that all employees have a right to know about all chemical hazards present in their workplace. The information is provided
3920_Ch01_002-026 23/01/14 9:20 AM Page 11
Chapter 1 | Safety and Quality Assessment
11
in the form of Material Safety Data Sheets (MSDSs) on file
in the workplace. By law, vendors are required to provide these
sheets to purchasers; however, the facility itself is responsible
for obtaining and making MSDSs available to employees. Information contained in an MSDS includes the following:
1. Physical and chemical characteristics
2. Fire and explosion potential
3. Reactivity potential
4. Health hazards and emergency first aid procedures
5. Methods for safe handling and disposal
6. Primary routes of entry
7. Exposure limits and carcinogenic potential
Radioactive Hazards
A
Radioactivity may be encountered in the clinical laboratory when procedures using radioisotopes are
performed. The amount of radioactivity present in
the clinical laboratory is very small and represents
little danger; however, the effects of radiation are cumulative
related to the amount of exposure. The amount of radiation
exposure is related to a combination of time, distance, and
shielding. Persons working in a radioactive environment are
required to wear measuring devices to determine the amount
of radiation they are accumulating.
Laboratory personnel should be familiar with the radioactive hazard symbol shown here. This symbol must be displayed
on the doors of all areas where radioactive material is present.
Exposure to radiation during pregnancy presents a danger to
the fetus; personnel who are pregnant or think they may be
should avoid areas with this symbol.
Electrical Hazards
B
Figure 1–4 Chemical safety aids. A, emergency shower; B, eye wash
station. (From Strasinger, SK, and DiLorenzo, MA: The Phlebotomy
Textbook, FA Davis, Philadelphia, 2011, with permission.)
The laboratory setting contains a large amount of
electrical equipment with which workers have frequent contact. The same general rules of electrical
safety observed outside the workplace apply. The danger of
water or fluid coming in contact with equipment is greater in
the laboratory setting. Equipment should not be operated with
wet hands. Designated hospital personnel monitor electrical
equipment closely; however, laboratory personnel should continually observe for any dangerous conditions, such as frayed
cords and overloaded circuits, and report them to the supervisor. Equipment that has become wet should be unplugged and
allowed to dry completely before reusing. Equipment also
should be unplugged before cleaning. All electrical equipment
must be grounded with three-pronged plugs.
When an accident involving electrical shock occurs, the electrical source must be removed immediately. This must be done
without touching the person or the equipment involved to avoid
transferring the current. Turning off the circuit breaker, unplugging the equipment, or moving the equipment using a nonconductive glass or wood object are safe procedures to follow. The
victim should receive immediate medical assistance following
3920_Ch01_002-026 23/01/14 9:20 AM Page 12
12
Part One | Background
A
B
C
Figure 1–5 Chemical hazard symbols. (From Strasinger, SK, and DiLorenzo, MA: The Phlebotomy Textbook, FA Davis, Philadelphia, 2011, with
permission.)
discontinuation of the electricity. Cardiopulmonary resuscitation
(CPR) may be necessary.
Fire/Explosive Hazards
The Joint Commission (JC) requires that all health-care
institutions post evacuation routes and detailed plans
to follow in the event of a fire. Laboratory personnel
should be familiar with these procedures. When a fire
is discovered, all employees are expected to take the actions in the
acronym RACE:
Rescue—rescue anyone in immediate danger
Alarm—activate the institutional fire alarm system
Contain—close all doors to potentially affected areas
Extinguish/Evacuate—attempt to extinguish the fire, if possible
or evacuate, closing the door
As discussed previously, laboratory workers often use
potentially volatile or explosive chemicals that require special
procedures for handling and storage. Flammable chemicals
should be stored in safety cabinets and explosion-proof refrigerators, and cylinders of compressed gas should be located
away from heat and securely fastened to a stationary device to
prevent accidental capsizing. Fire blankets may be present in
the laboratory. Persons with burning clothes should be
wrapped in the blanket to smother the flames.
The NFPA classifies fires with regard to the type of burning
material. It also classifies the type of fire extinguisher that is used
to control them. This information is summarized in Table 1–2.
The multipurpose ABC fire extinguishers are the most common,
3920_Ch01_002-026 23/01/14 9:20 AM Page 13
Chapter 1 | Safety and Quality Assessment
HAZARDOUS MATERIALS
CLASSIFICATION
FIRE HAZARD
Flash Point
HEALTH HAZARD
4
3
2
1
0
Deadly
Extreme Danger
Hazardous
Slightly Hazardous
Normal Material
2
3
SPECIFIC
HAZARD
Oxidizer
Acid
Alkali
Corrosive
Use No Water
Radiation
4
3
2
1
0
Below 73 F
Below 100 F
Below 200 F
Above 200 F
Will not burn
1
W
OXY
ACID
ALK
COR
W
REACTIVITY
4 May deteriorate
3 Shock and heat
may deteriorate
2 Violent chemical
change
1 Unstable if
heated
0 Stable
Figure 1–6 NFPA hazardous material symbols.
but the label should always be checked before using. It is important to be able to operate the fire extinguishers. The acronym
PASS can be used to remember the steps in the operation:
1. Pull pin
2. Aim at the base of the fire
3. Squeeze handles
4. Sweep nozzle side to side
Physical Hazards
Physical hazards are not unique to the laboratory,
and routine precautions observed outside the workplace apply. General precautions to consider are to
avoid running in rooms and hallways, watch for wet
Table 1–2
Types of Fires and Fire Extinguishers
Fire Type
Extinguishing Material
Class A
Class B
Class C
Class D
Wood, paper, clothing
Flammable organic chemicals
Electrical
Combustible metals
Class K
Grease, oils, fats
13
floors, bend the knees when lifting heavy objects, keep long
hair pulled back, avoid dangling jewelry, and maintain a clean,
organized work area. Closed-toed shoes that provide maximum support are essential for safety and comfort.
Q UA L I T Y
A SSE S SMEN T
The term quality assessment (QA) refers to the overall process
of guaranteeing quality patient care and is regulated throughout
the total testing system. Quality system refers to all of the laboratory’s policies, processes, procedures, and resources needed to
achieve quality testing.15 In a clinical laboratory, a quality assessment program includes not only testing controls, referred to as
quality control (QC), but also encompasses preexamination
variables (e.g., specimen collection, handling, and storage), examination variables (e.g., reagent and test performance, instrument calibration and maintenance, personnel requirements, and
technical competence), postexamination variables (e.g., reporting of results and interpretation), and documentation that the
program is being meticulously followed. The original terms preanalytical, analytical, and postanalytical have been replaced with
the International Organization for Standardization (ISO) standard
terms of preexamination, examination, and postexamination.
Included in a QA program are procedure manuals, internal
quality control, external quality control, electronic quality
control, calibration or calibration verification, standardization,
proficiency testing (PT), more formally known as external
quality assessment (EQA),16 record keeping, equipment maintenance, safety programs, training, education and competency
assessment of personnel, and a scheduled and documented
review process. Essentially, QA is the continual monitoring of the
entire test process from test ordering and specimen collection
through reporting and interpreting results. Written policies and
documented actions as they relate to the patient, the laboratory,
ancillary personnel, and the health-care provider are required.
Having written remedial actions mandating the steps to take
when any part of the system fails is essential to a QA program.
QA in the urinalysis laboratory—or any other laboratory
department—is an integration of many factors. This section
Type/Composition
of Fire
Extinguisher
Class A
Class B
Class C
None
Class ABC
Class K
Water
Dry chemicals, carbon dioxide, foam, or halon
Dry chemicals, carbon dioxide, or halon
Sand or dry powder
Dry chemicals
Liquid designed to prevent splashing and cool the fire.
From Strasinger, SK and DiLorenzo, MA: The Phlebotomy Textbook, third edition, FA Davis, Philadelphia, 2011, p.73, with permission.
3920_Ch01_002-026 23/01/14 9:20 AM Page 14
14
Part One | Background
will provide a collection of the procedures essential for providing quality urinalysis. In the following chapters, the methods
of ensuring accurate results will be covered on an individual
basis for each of the tests.
Documentation of QA procedures is required by all laboratory accreditation agencies, including the Joint Commission
(JC), College of American Pathologists (CAP), American Association of Blood Banks (AABB), American Osteopathic Association
(AOA), American Society of Histocompatibility and Immunogenetics (ASHI), and the Commission on Laboratory Assessment
(COLA); it is also required for Medicare reimbursement. Guidelines published by CAP and the CLSI provide very complete
instructions for documentation and are used as a reference for
the ensuing discussion of the specific areas of urinalysis QC
and QA.16–18
Documentation in the form of a procedure manual is
required in all laboratories, and this format is used as the basis
for the following discussion.
URINALYSIS SECTION
SPECIMEN ACCEPTABILITY/LABELING
Prepared by:
Initial approval:
Procedure placed in use:
Revised:
Reason for revision:
Effective Date Supervisor Approval Medical Director Approval
Reviewed
Reviewed
Reviewed
Reviewed
Urinalysis Procedure Manual
A procedure manual containing all the procedures performed
in the urinalysis section must be available for reference in the
working area and must comply with the CLSI guidelines. The
following information is included for each procedure: principle
or purpose of the test, clinical significance, patient preparation,
specimen type and method of collection, specimen acceptability
and criteria for rejection, reagents, standards and controls, instrument calibration and maintenance protocols and schedules, stepby-step procedure, calculations, frequency and tolerance limits
for controls and corrective actions, reference values and critical
values, interpretation of results, specific procedure notes, limitations of the method, method validation, confirmatory testing,
recording of results, references, effective date, author, and review
schedule. Current package inserts should be reviewed and available at the workplace. Electronic manuals are acceptable and
must be readily available to all personnel. As with written procedural manuals, electronic versions must be subjected to proper
document control (i.e., only authorized persons may make
changes, changes are dated/signed [manually or electronically],
and there is documentation of periodic review).17,18
Evaluating procedures and adopting new methodologies
is an ongoing process in the clinical laboratory. Whenever
changes are made, the procedure should be reviewed, referenced, and signed by a person with designated authority, such
as the laboratory director or section supervisor (Fig. 1–7), and
personnel should be notified of the changes. Documentation
of an annual review of all procedures by the designated authority must also be substantiated.
Preexamination Variables
Preexamination variables occur before the actual testing of the
specimen and include test requests, patient preparation, timing,
specimen collection, handling, and storage. Health-care personnel outside the clinical laboratory control many of these factors,
such as ordering tests and specimen collection. Communication
Reviewed
Figure 1–7 Example of procedure review documentation. (Adapted
from the Department of Pathology, St. Joseph Hospital, Omaha, NE.)
between departments and adequate training on the correct procedures for ordering a test, collecting, and transporting the specimen improves the turnaround time (TAT) of results, avoids
duplication of test orders, and ensures a high-quality specimen.
TAT is defined as the amount of time required from the point
at which a test is ordered by the health-care provider until the
results are reported to the health-care provider. Laboratories
determine the TAT for tests including both stat and routine tests
as appropriate. The laboratory can then monitor the TATs to
determine areas in the process that need improvement. This can
be determined by creating a cause-and-effect diagram, as shown
in Figure 1–8.
Specimen Collection and Handling
Specific information on specimen collection and handling
should be stated at the beginning of each procedure listed in
the manual. Requisition forms and computerized entry forms
should designate the type of urine specimen to be collected
and the date and time of collection. The form should include
space for recording (1) the actual date and time of specimen
collection, (2) whether the specimen was refrigerated before
transporting, (3) the time the specimen was received in the
laboratory and the time the test was performed, (4) tests requested, (5) an area for specific instructions that might affect
the results of the analysis, and (6) patient identification information.18 The patient’s sex, age or date of birth, and, when
appropriate, the source of the specimen and the time it was
collected must be documented.15
Patient preparation (e.g., fasting or elimination of interfering medications), type and volume of specimen required,
3920_Ch01_002-026 23/01/14 9:20 AM Page 15
Chapter 1 | Safety and Quality Assessment
CAUSE-AND-EFFECT DIAGRAM
URINALYSIS TURN-AROUND-TIME (TAT)
Collection
Transport
Missed collection
15
Delayed delivery
Incorrect specimen type Contaminated specimen container
Insufficient urine volume
Patient misidentification
Special conditions not followed
Lost label
Insufficient container
No requisition Leaking closure lid
Missed pick-up
Specimen misplaced
Incorrect storage
No chemical preservative
Patient preparation
Incorrect container
Time of collection not indicated
Distance
Transport staff
unavailable
Not refrigerated
Not fasting Medications
Incomplete requisition
UA results
TAT
Interfering substances
Instrument malfunction
Report not charted
Procedure failure
Computer down
Wrong specimen tested
Printer error
Failure to send report
Inadequate volume
Test analysis
Reporting
Figure 1–8 Cause-and-effect diagram for analyzing urinalysis TAT.
and the need for sterile or opaque containers must be included
with the specific procedure. All urine specimens should be
examined within 2 hours. If this is not possible, written instructions for preserving the specimen must be available.18
Instructions of a general nature, such as procedures for
collecting clean-catch and timed specimens, specimen processing, and printed instructions that are given to patients, are also
included in the manual.
Criteria for specimen rejection for both physical characteristics and labeling errors must be present. In Table 1–3 is
Table 1–3
an example of a policy for handling mislabelled specimens.
Written criteria for rejecting specimens must be documented
and available to the health-care provider and nursing staff.18
Table 1–4 lists the criteria for urine specimen rejection.
Laboratory personnel must determine the suitability of a
specimen and document any problems and corrective actions
taken. An example of an internal laboratory quality improvement form is shown in Figure 1–9. It is used as a tool to document a problem at the point of discovery, describing what
happened and the immediate corrective action taken. This
Policy for Handling Mislabeled Specimens
Do NOT assume any information about the specimen or patient.
Do NOT relabel an incorrectly labeled specimen.
Do NOT discard the specimen until investigation is complete.
Leave specimen EXACTLY as you receive it; put in the refrigerator for preservation until errors can be resolved.
Notify floor, nursing station, doctor’s office, etc. of problem and why it must be corrected for analysis to continue.
Identify problem on specimen requisition with date, time, and your initials.
Make person responsible for specimen collection participate in solution of problem(s). Any action taken should be
documented on the requisition slip.
Report all mislabeled specimens to the appropriate supervisor.
From Schweitzer, SC, Schumann, JL, and Schumann, GB: Quality assurance guidelines for the urinalysis laboratory. Journal of Medical Technology
3(11): 568, 1986, with permission.
3920_Ch01_002-026 23/01/14 9:20 AM Page 16
16
Part One | Background
Table 1–4
Criteria for Urine Specimen Rejection
Unlabeled containers
Nonmatching labels and requisition forms
Contaminated specimens with feces or toilet paper
Containers with contaminated exteriors
Insufficient volume of urine
Improperly transported or preserved specimens
Delay between time of collection and receipt in the
laboratory
enables the laboratory director to capture the information to
determine the root cause analysis and develop a preventive or
corrective action plan. Laboratory information systems have the
capability to electronically generate these forms for review. An
acceptable specimen requires verification of the patient’s identification information on the requisition form and the container
label, timely transport to the laboratory, the presence of refrigeration or recommended preservative if transport was delayed,
and collection of an adequate amount of the correct urine specimen type in a noncontaminated, tightly closed container.18
Examination Variables
The examination variables are the processes that directly affect
the testing of specimens. They include reagents, instrumentation and equipment, testing procedure, QC, preventive maintenance (PM), access to procedure manuals, and competency
of personnel performing the tests.
Reagents
The manual should state the name and chemical formula of each
reagent used, instructions for preparation, when necessary, or
company source of prepared materials, storage requirements, and
procedures for reagent QC. The type of water used for preparing
reagents and controls must be specified. Distilled or deionized
water or clinical laboratory reagent water (CLRW) must be available. A bold-type statement of any safety or health precautions
associated with reagents should be present. An example of this
would be the heat produced in the Clinitest reaction.
All reagents and reagent strips must be properly labeled
with the date of preparation or opening, purchase and received
date, expiration date, and appropriate safety information.
Reagent strips should be checked against known negative and
positive control solutions on each shift or at a minimum once
a day, and whenever a new bottle is opened. Reagents are
checked daily or when tests requiring their use are requested.
Results of all reagent checks are properly recorded. Reagent
strips must never be refrigerated, and must be recapped immediately after removing each strip.
when limitations or linearity are exceeded, such as dilution
procedures, must be clearly stated in the procedure manual.
Instructions detailing the appropriate recording procedures
must be included.
The most frequently encountered instruments in the urinalysis laboratory are refractometers, osmometers, automated
reagent strip readers, and automated microscopy instruments.
Refractometers are calibrated on each shift against deionized
water (1.000) and a known control, such as 5% saline (1.022 ±
0.001) or 9% sucrose (1.034 ± 0.001). Two levels of commercial controls are available for the osmometer, urine reagent
strip tests, and hCG kit tests. All control values must be
recorded. Automated urinalysis systems and reagent strip readers are calibrated using manufacturer-supplied calibration
materials following the protocol specified by the manufacturer.
Both positive and negative control values must be run and
recorded (Fig. 1–10). Evidence of corrective action for any
failed QC tests must be documented. No patient’s testing may
be performed until QC is acceptable.
Equipment found in the urinalysis laboratory commonly
includes refrigerators, centrifuges, microscopes, and water
baths. Temperatures of refrigerators and water baths should be
taken daily and recorded. Calibration of centrifuges is customarily performed every 3 months, and the appropriate relative
centrifugal force for each setting is recorded. Centrifuges are
routinely disinfected on a weekly basis. Microscopes should be
kept clean at all times and have an annual professional cleaning. A routine PM schedule for instruments and equipment
should be prepared as mandated by the JC or CAP guidelines,
and records kept of all routine and nonroutine maintenance
performed.
Deionized water used for reagent preparation is quality
controlled by checking pH and purity meter resistance on a
weekly basis and the bacterial count on a monthly schedule.
All results must be recorded on the appropriate forms.
Testing Procedure
Detailed, concise testing instructions are written in a stepby-step manner. Instructions should begin with specimen
preparation, such as time and speed of centrifugation, and include types of glassware needed, time limitations and stability
of specimens and reagents, calculation formulas and a sample
calculation, health and safety precautions, and procedures. Additional procedure information including reasons for special
precautions, sources of error and interfering substances, helpful
hints, clinical situations that influence the test, alternative procedures, and acceptable TATs for stat tests are listed under the
title of Procedure Notes following the step-by-step procedure.
Reference sources should be listed. Manufacturer’s package
inserts may be included but cannot replace the written procedure. The laboratory director must sign and date new procedures and all modifications of procedures before they are used.15
Instrumentation and Equipment
Quality Control
Instructions regarding the operation, performance and frequency of calibration, limitations, and procedures to follow
Quality control refers to the materials, procedures, and techniques that monitor the accuracy, precision, and reliability
3920_Ch01_002-026 23/01/14 9:20 AM Page 17
Chapter 1 | Safety and Quality Assessment
17
Quality Improvement Follow-up Report
CONFIDENTIAL
Instructions: Section I should be completed by the individual identifying the event.
Date of report:
Date of incident:
Patient MR#
Reported by:
Date/time of discovery:
Patient accession#
Section I
Summary of incident — describe what happened
What immediate corrective action was taken?
Provide the ORIGINAL to team leader/technical specialist within 24 hours of incident discovery
Date:
To:
Forwarded for follow-up:
Date:
To:
Section II. Management investigation: Tracking #
Instructions: Section II should be completed by laboratory management within 72 hours
Check appropriate problem category
Unacceptable patient samples
(Due to hemolysis, QNS, or contaminated)
Wrong tube type
Equipment-related event
Misidentified sample
Standard operating procedure deviation
Wrong location
Communication problem/complaint
Other (explain)
Accident
Explain answers:
Preventive/corrective action recommendations:
Technical specialist/team leader:
Date:
Medical director review:
Date:
Quality assurance review:
Date:
FDA reportable: Yes or no
Date reported:
Figure 1–9 Sample of Quality Improvement Follow-up Report form. (From Danville Regional Medical Center Laboratory, Danville, VA, with
permission.)
3920_Ch01_002-026 23/01/14 9:20 AM Page 18
18
Part One | Background
QUALITY CONTROL
GLU
mg/dL
BIL
Month:__________20_____
Positive control
SP BLD PH PROT NIT
GR
mg/dL 1.0
mg/dL
KET
Negative control
LEU GLU BIL KET SP BLD PH PROT NIT
EST
GR
mg/dL
mg/dL 1.0
mg/dL
LEU
EST
Control values
Reagent
Lot #
EXP
TECH DATE
Figure 1–10 Sample instrument QC recording sheet. (Adapted from the Department of Pathology, Methodist Hospital, Omaha, NE, with
permission.)
of a laboratory test. QC procedures are performed to ensure
that acceptable standards are met during the process of patient
testing. Specific QC information regarding the type of control
specimen preparation and handling, frequency of use, tolerance levels, and methods of recording should be included in
the step-by-step instructions for each test. QC is performed at
scheduled times, such as at the beginning of each shift or before testing patient samples, and it must always be performed
if reagents are changed, an instrument malfunction has occurred, or if test results are questioned by the health-care
provider. Control results must be recorded in a log, either
paper or electronic. Patient test results may not be reported
until the QC is verified. Both external quality control monitoring and internal and electronic quality control processes are
practiced in the urinalysis laboratory.
External Quality Control
External quality controls are used to verify the accuracy (ability
to obtain the expected result) and precision (ability to obtain
the same result on the same specimen) of a test and are exposed to the same conditions as the patient samples. Reliability
is the ability to maintain both precision and accuracy. Commercial controls are available for the urine chemistry tests, specific gravity, and for certain microscopic constituents. Analysis
of two levels of control material is required. The concentration
of controls should be at medically significant levels and should
be as much like the human specimen as possible. Documentation of QC includes dating and initialling the material when it
is first opened and recording the manufacturer’s lot number
and the expiration date each time a control is run and the test
result is obtained. Food and Drug Administration (FDA) standards require that control material test negative for HIV and
hepatitis B virus. External controls are tested and interpreted
in the laboratory by the same person performing the patient
testing.
Control data are evaluated before releasing patient results.
Data obtained from repeated measurements have a Gaussian
distribution or spread in the values that indicate the ability to
repeat the analysis and obtain the same value. The laboratory,
after repeated testing, establishes the value for each analyte,
and the mean and standard deviation is calculated. The control
mean is the average of all data points and the standard deviation (SD) is a measurement statistic that describes the average
distance each data point in a normal distribution is from the
mean. The coefficient of variation (CV) is the SD expressed
as a percentage of the mean. The CV indicates whether the distribution of values about the mean is in a narrow versus broad
range and should be less than 5%. Confidence intervals are the
limits between which the specified proportion or percentage
of results will lie. Control ranges are determined by setting
confidence limits that are within ±2 SD or ±3 SD of the mean,
which indicates that 95.5% to 99.7% of the values are expected
to be within that range.
Values are plotted on Levy-Jennings control charts to
visually monitor control values. Immediate decisions about patient results are based on the ability of control values to remain
within a preestablished limit. Changes in accuracy of results
are indicated by either a trend that is a gradual changing in
the mean in one direction or a shift that is an abrupt change
in the mean (Fig. 1–11). Changes in precision are shown by a
large amount of scatter about the mean and an uneven distribution above and below the mean that are most often caused
by errors in technique.
Corrective action, including the use of new reagents,
reagent strips, or controls, and the verification of lot numbers
and expiration dates, must be taken when control values are
outside the tolerance limits. All corrective actions taken are
documented. A protocol for corrective action is shown in
Figure 1–12. A designated supervisor reviews all QC results.
Laboratories may participate in a commercial QC program. Results from the same lot of QC material sent by the
manufacturer to participating laboratories are returned to the
manufacturer for statistical analysis and comparison with other
laboratories using the same methodology.
Internal Quality Control
Internal quality control consists of internal monitoring systems
built in to the test system and are called internal or procedural
controls.16,19 Internal controls monitor the sufficient addition
of a patient specimen or reagent, the instruments/reagents
3920_Ch01_002-026 23/01/14 9:20 AM Page 19
Chapter 1 | Safety and Quality Assessment
2
4
6
8
Day
10 12
19
A. Record all actions taken and the resolution of any problems
14
16
18
B. Use the flow diagram below:
20
+ 2 S.D.
+ 1 S.D.
X
– 1 S.D.
– 2 S.D.
In Control
+ 2 S.D.
+ 1 S.D.
X
– 1 S.D.
– 2 S.D.
Shift
1. Run control
In control
Out of control
Proceed with
testing
Go to Step 2
2. Inspect control for: Outdate (age), proper storage,
correct lot number, signs of contamination
Yes there is a problem
No obvious explanation
Make new control
and retest
Retest
+ 2 S.D.
+ 1 S.D.
X
– 1 S.D.
– 2 S.D.
Trend
Figure 1–11 Levy-Jennings charts showing in-control, shift, and trend
results.
interaction, and, for lateral flow test methods, whether the
sample migrated through the test strip properly.16
Electronic Controls
External quality control (EQC) uses a mechanical or electrical
device in place of a liquid QC specimen. This type of QC can be
internal or an external component inserted into a point of care
(POC) instrument. EQC verifies the functional ability of a testing
device, but it does not verify the integrity of the testing supplies.
Many test systems use a combination of external and internal
controls to verify that the entire test system is working properly.
Proficiency Testing (External Quality Assessment)
PT or EQA is the testing of unknown samples received from an
outside agency, and provides unbiased validation of the quality of
patient test results. Several commercial vendors provide proficiency testing such as CAP. Laboratories subscribing to these programs receive lyophilized or ready-to-use specimens for routine
urinalysis and Kodachromes or color plates for sediment constituent identification. The results are returned to the proficiency
testing vendors, where they are statistically analyzed with those
from all participating laboratories, and a report is returned to the
laboratory director. The laboratory accuracy is evaluated and compared with other laboratories using the same method of analysis.
Corrective action must be taken for unacceptable results.16 The
Clinical Laboratory Improvement Amendments (CLIA) mandates comparison testing for laboratory accreditation.19
Personnel and Facilities
Quality control is only as good as the personnel performing
and monitoring it. Personnel assessment includes education
In control
Out of control
Proceed with
testing
Go to Step 3
3. Make up new bottle of control
In control
Out of control
Discard old control
and proceed with testing
Go to Step 4
4. Open new can of reagent strips and test with new control
In control
Out of control
Discard bad reagent strips
and proceed with testing
Switch lot numbers
and retest
In control
Discard entire lot,
notify manufacturer,
and proceed with testing
Out of control
Notify supervisor or
resource person: do not
proceed with testing
Figure 1–12 “Out-of-control” procedures. (From Schweitzer, SC,
Schumann, JL, and Schumann, GB: Quality assurance guidelines for
the urinalysis laboratory. Journal of Medical Technology 3(11):567–572,
1986, with permission.)
and training, continuing education, competency assessment,
and performance appraisals. Each new employee must have
documentation of training during orientation to the laboratory.
This is a checklist of procedures and must include date and
initials of the person doing the training and of the employee
being trained. Up-to-date reference materials and atlases
should be readily available, and documentation of continuing
education must be maintained.16
An adequate, uncluttered, safe working area is also
essential for both quality work and personnel morale. Standard precautions for handling body fluids must be followed
at all times.
3920_Ch01_002-026 23/01/14 9:20 AM Page 20
20
Part One | Background
Postexamination Variables
Postexamination variables are processes that affect the reporting of results and correct interpretation of data.
Reporting Results
Standardized reporting formats and, when applicable, reference ranges should be included with each procedure covered
in the procedure manual. A written procedure for reporting,
reviewing, and correcting errors must be present.
Forms for reporting results should provide adequate space
for writing and should present the information in a logical sequence. Standardized reporting methods minimize health-care
provider confusion when interpreting results (Fig. 1–13).
Electronic transmission is now the most common method
for reporting results. Many urinalysis instruments have the capability for the operator to transmit results directly from the
instrument to the designated health-care provider. It is essential
that the operator carefully review results before transmittal. Results may also be manually entered into the laboratory computer system and then transmitted to the health-care providers.
MICROSCOPIC QUANTITATIONS
Quantitate an average of 10 representative fields. Do not quantitate
budding yeast, mycelial elements, Trichomonas, or sperm, but do
note their presence with the appropriate LIS code.
Epithelial cells/LPF
None:
Rare:
Few:
Moderate:
Many:
Casts/LPF
None:
Numerical ranges:
RBCs/HPF
None:
Numerical ranges:
WBCs/HPF
None:
Numerical ranges:
Crystals/HPF
None:
Rare:
Few:
Moderate:
Many:
Bacteria/HPF
None:
Rare:
Few:
Moderate:
Many:
Mucous threads
Rare:
Few:
Moderate:
Many:
0
0–5
5–20
20–100
>100
0
0–2, 2–5, 5–10, >10
0
0–2, 2–5, 5–10, 10–25, 25–50, 50–100, >100
0
0–2, 2–5, 5–10, 10–25, 25–50, 50–100, >100
0
0–2
2–5
5–20
>20
0
0–10
10–50
50–200
>200
0–1
1–3
3–10
>10
Figure 1–13 Sample standardized urine microscopic reporting
format. (From University of Nebraska Medical Center, Omaha, NE, with
permission.)
Errors may be discovered in the laboratory through a QA
procedure known as the delta check that compares a patient’s
test results with the previous results. Variation outside the established parameters alerts laboratory personnel to the possibility of an error that occurred during the testing procedure or
in patient identification. Autoverification is often programmed
into many laboratory analyzers.4
Erroneous results must be corrected in a timely manner
to assure that the patient does not receive treatment based on
incorrect results. Errors can occur in patient identification,
specimen labeling, or result transcription. The patient’s record
should be corrected as soon as the error is detected; however,
the original result must not be erased in the event that the
health-care provider treated the patient based on the erroneous
results. Appropriate documentation of erroneous results should
follow institutional protocol.
The telephone is frequently used to transmit results of stat
tests and critical values. Calls requesting additional results may
be received from personnel on hospital units and from healthcare providers. When telephoning results, confirm that the results are being reported to the appropriate person. The time of
the call and the name of the person receiving the results must
be documented according to the facility’s policy. The Joint
Commission Patient Safety Goals require that when verbally
reporting test results the information must be repeated by the
person receiving the information and documented by the person giving the report.
Written procedures should be available for the reporting
of critical values (Fig. 1–14). In laboratories analyzing pediatric
Reporting Critical Results In Urinalysis
POSITIVE KETONES
For children age 2 years and younger:
All results positive for ketones should be telephoned to the
appropriate nursing unit.
Document the following information in the computer as a
chartable footnote appended to the result:
Time of telephone call
Initials of the person making the call
Name of the person receiving the telephone call
POSITIVE CLINITEST
For children age 2 years and younger:
All Clinitest results should be telephoned to the appropriate
nursing unit.
Document the following information in the computer as a
chartable footnote appended to the result:
Time of telephone call
Initials of the person making the call
Name of the person receiving the telephone call
Figure 1–14 An example of procedure instructions for reporting
critical values in the urinalysis section. A procedure review document
similar to that shown in Figure 1–7 would accompany this instruction
sheet.
3920_Ch01_002-026 23/01/14 9:20 AM Page 21
Chapter 1 | Safety and Quality Assessment
SUMMARY 1-1
Quality Assessment Errors
Preexamination
Patient misidentification
Wrong test ordered
Incorrect urine specimen type collected
Insufficient urine volume
Delayed transport of urine to the laboratory
Incorrect storage or preservation of urine
Examination
Sample misidentification
Erroneous instrument calibration
Reagent deterioration
Poor testing technique
Instrument malfunction
Interfering substances present
Misinterpretation of quality control data
Postexamination
Patient misidentification
Poor handwriting
Transcription error
Poor quality of instrument printer
Failure to send report
Failure to call critical values
Inability to identify interfering substances
specimens, this should include the presence of ketones or
reducing substances in newborns.
Interpreting Results
The specificity and the sensitivity for each test should be included in the procedure manual for correct interpretation of
results. Sensitivity and specificity vary among manufacturers.
All known interfering substances should be listed for evaluation of patient test data. A well-documented QA program
ensures quality test results and patient care.
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Clinical and Laboratory Standards Institute: Protection of laboratory workers from occupationally acquired infections: approved
guideline, ed 3, CLSI Document M29-A3, Clinical and Laboratory Standards Institute, Wayne, PA, 2005, CLSI.
2. Clinical and Laboratory Standards Institute: Clinical laboratory
safety: approved guideline, ed 2, CLSI Document GP17-A2,
Clinical and Laboratory Standards Institute, Wayne, PA, 2004,
CLSI.
21
3. Clinical and Laboratory Standards Institute: Clinical laboratory
waste management: approved guideline, ed 2, CLSI Document
GP05-A3, Clinical and Laboratory Standards Institute, Wayne,
PA, 2005, CLSI.
4. Strasinger SK, Di Lorenzo MS, The Phlebotomy Textbook, ed 3,
2011. F.A. Davis, Philadelphia.
5. Centers for Disease Control and Prevention. Guidelines for
Isolation Precautions: Preventing Transmission of Infectious
Agents in Healthcare Settings, 2007. www.cdc.gov/hicpac/
2007isolationPrecations.html.
6. Occupational Exposure to Blood-Borne Pathogens, Final Rule.
Federal Register 29 (Dec 6), 1991.
7. Occupation Safety and Health Administration. Revision to OSHA’s
Bloodborne Pathogens Standard. 2001. Department of Labor. Web
site: www.osha.gov/SLTC/bloodbornepathogens.
8. Centers for Disease Control and Prevention. Updated U.S.
Public Health Service Guidelines for the Management of Occupational Exposures to HBV, HCV and HIV and Recommendations for Post-exposure Prophylaxis. MMWR June 29, 2001:
50(RR11); 1–42. Web site: www.cdc.gov
9. Centers for Disease Control and Prevention. Updated U.S.
Public Health Service Guidelines for the Management of Occupational Exposure to HIV and Recommendations for Postexposure Prophylaxis. MMWR September 17, 2005: 54(RR09);
1–17. Web site: www.cdc.gov
10. NIOSH Alert. Preventing Allergic Reactions to Natural Rubber
Latex in the Workplace. DHHS (NIOSH) Publication 97-135.
National Institute for Occupational Safety and Health, Cincinnati, OH, 1997.
11. Centers for Disease Control and Prevention. Guideline for
Hand Hygiene in Health-Care Settings: Recommendations of
the Healthcare Infection Control Practices Advisory Committee
and the HICPAC/SHEA/APIC/IDSA Hand Hygiene Task Force,
MMWR 2002:51(RR16). [Inclusive page numbers]
12. Centers for Disease Control and Prevention. Guideline for
Disinfection and Sterilization in Healthcare Facilities, 2008.
Web site: www.cdc.gov/hicpac/pdf/guidelines/Disinfection_
Nov_2008.pdf
13. Occupational Exposure to Hazardous Chemicals in Laboratories, Final Rule. Federal Register 55 (Jan 31), 1990.
14. National Fire Protection Association: Hazardous Chemical
Data, No. 49. Boston, NFPA, 1991.
15. Centers for Medicare & Medicaid Services, Department of
Health and Human Services: Clinical Laboratory Improvement
Amendments, Updated Regulations, Brochure #1, How do
they affect my laboratory? www.cms.hhs.gov/CLIA/05_CLIA_
Brochures.asp Accessed November 2006.
16. Clinical and Laboratory Standards Institute (CLSI): Quality
Practices in Noninstrumented Point of Care Testing: An
Instructional Manual and Resources for Health Care Workers.
Approved Guideline. CLSI document POCT08-A, Wayne,
PA, 2010.
17. College of American Pathologists: Commission on Laboratory
Accreditation, Urinalysis Checklist. College of American
Pathologists, Skokie, IL, 2005.
18. Clinical and Laboratory Standards Institute (CLSI), Urinalysis:
Approved Guideline-Third Edition, CLSI document GP16-A3,
2009.
19. Centers for Medicare & Medicaid Services, Department of
Health and Human Services: Clinical Laboratory Improvement
Amendments, Brochure #4: Equivalent Quality Control Procedures. www.cms.hhs.gov/CLIA/05_CLIA_Brochures.asp Accessed
November 2006.
3920_Ch01_002-026 23/01/14 9:20 AM Page 22
22
Part One | Background
Study Questions
1. In the urinalysis laboratory the primary source in the
chain of infection would be:
A. Patients
B. Needlesticks
C. Specimens
D. Biohazardous waste
2. The best way to break the chain of infection is:
A. Hand sanitizing
B. Personal protective equipment
C. Aerosol prevention
D. Decontamination
3. The current routine infection control policy developed
by CDC and followed in all health-care settings is:
A. Universal Precautions
B. Isolation Precautions
C. Blood and Body Fluid Precautions
D. Standard Precautions
4. An employee who is accidentally exposed to a possible
blood-borne pathogen should immediately:
A. Report to a supervisor
B. Flush the area with water
C. Clean the area with disinfectant
D. Receive HIV prophylaxis
5. Personnel in the urinalysis laboratory should wear lab
coats that:
A. Do not have buttons
B. Are fluid-resistant
C. Have short sleeves
D. Have full-length zippers
6. All of the following should be discarded in biohazardous
waste containers except:
A. Urine specimen containers
B. Towels used for decontamination
C. Disposable lab coats
D. Blood collection tubes
7. An employer who fails to provide sufficient gloves for
the employees may be fined by the:
A. CDC
B. NFPA
C. OSHA
D. FDA
8. An acceptable disinfectant for blood and body fluid
decontamination is:
A. Sodium hydroxide
B. Antimicrobial soap
C. Hydrogen peroxide
D. Sodium hypochlorite
9. Proper handwashing includes all of the following
except:
A. Using warm water
B. Rubbing to create a lather
C. Rinsing hands in a downward position
D. Turning on the water with a paper towel
10. Centrifuging an uncapped specimen may produce a
biologic hazard in the form of:
A. Vectors
B. Sharps contamination
C. Aerosols
D. Specimen contamination
11. An employee who accidentally spills acid on his arm
should immediately:
A. Neutralize the acid with a base
B. Hold the arm under running water for 15 minutes
C. Consult the MSDSs
D. Wrap the arm in gauze and go to the emergency
department
12. When combining acid and water, ensure that:
A. Acid is added to water
B. Water is added to acid
C. They are added simultaneously
D. Water is slowly added to acid
13. An employee can learn the carcinogenic potential of
potassium chloride by consulting the:
A. Chemical hygiene plan
B. Material safety data sheets
C. OSHA standards
D. Urinalysis procedure manual
14. Employees should not work with radioisotopes if
they are:
A. Wearing contact lenses
B. Allergic to iodine
C. Sensitive to latex
D. Pregnant
3920_Ch01_002-026 23/01/14 9:20 AM Page 23
Chapter 1 | Safety and Quality Assessment
23
15. All of the following are safe to do when removing the
source of an electric shock except:
A. Pulling the person away from the instrument
B. Turning off the circuit breaker
C. Using a glass container to move the instrument
D. Unplugging the instrument
23. The classification of a fire that can be extinguished with
water is:
A. Class A
B. Class B
C. Class C
D. Class D
16. The acronym PASS refers to:
A. Presence of vital chemicals
B. Operation of a fire extinguisher
C. Labeling of hazardous material
D. Presence of radioactive substances
24. Employers are required to provide free immunization for:
A. HIV
B. HTLV-1
C. HBV
D. HCV
17. The system used by firefighters when a fire occurs in the
laboratory is:
A. MSDS
B. RACE
C. NFPA
D. PASS
25. A possible physical hazard in the hospital is:
A. Wearing closed-toed shoes
B. Not wearing jewelry
C. Having short hair
D. Running to answer the telephone
18. A class ABC fire extinguisher contains:
A. Sand
B. Water
C. Dry chemicals
D. Acid
26. Quality assessment refers to:
A. Analysis of testing controls
B. Increased productivity
C. Precise control results
D. Quality of specimens and patient care
19. The first thing to do when a fire is discovered is to:
A. Rescue persons in danger
B. Activate the alarm system
C. Close doors to other areas
D. Extinguish the fire if possible
27. During laboratory accreditation inspections, procedure
manuals are examined for the presence of:
A. Critical values
B. Procedure references
C. Procedures for specimen preservation
D. All of the above
20. If a red rash is observed after removing gloves, the
employee:
A. May be washing her hands too often
B. May have developed a latex allergy
C. Should apply cortisone cream
D. Should not rub the hands so vigorously
28. As supervisor of the urinalysis laboratory, you have just
adopted a new procedure. You should:
A. Put the package insert in the procedure manual
B. Put a complete, referenced procedure in the manual
C. Notify the microbiology department
D. Put a cost analysis study in the procedure manual
21. Pipetting by mouth is:
A. Acceptable for urine but not serum
B. Not acceptable without proper training
C. Acceptable for reagents but not specimens
D. Not acceptable in the laboratory
29. Indicate whether each of the following would be considered a 1) preexamination, 2) examination, or 3) postexamination factor by placing the appropriate number in
the blank:
_____ Reagent expiration date
_____ Rejecting a contaminated specimen
_____ Constructing a Levy-Jennings chart
_____ Telephoning a positive Clinitest result on a
newborn
_____ Calibrating the centrifuge
_____ Collecting a timed urine specimen
22. The NPFA classification symbol contains information on
all of the following except:
A. Fire hazards
B. Biohazards
C. Reactivity
D. Health hazards
3920_Ch01_002-026 23/01/14 9:20 AM Page 24
24
Part One | Background
30. The testing of sample from an outside agency and the comparison of results with participating laboratories is called:
A. External QC
B. Electronic QC
C. Internal QC
D. Proficiency testing
33. When a new bottle of QC material is opened, what
information is placed on the label?
A. The supervisor’s initials
B. The lot number
C. The date and the laboratory worker’s initials
D. The time the bottle was opened
31. A color change that indicates that a sufficient amount of
patient’s specimen or reagent is added correctly to the
test system would be an example of:
A. External QC
B. Equivalent QC
C. Internal QC
D. Proficiency testing
34. When a control is run, what information is
documented?
A. The lot number
B. Expiration date of the control
C. The test results
D. All of the above
32. What steps are taken when the results of reagent strip
QC are outside of the stated confidence limits?
A. Check the expiration date of the reagent strip
B. Run a new control
C. Open a new reagent strips container
D. All of the above
Case Studies and Clinical Situations
1. State a possible reason for an accreditation team to
report a deficiency in the following situations:
a. The urine microscopic reporting procedure has
been recently revised.
b. An unusually high number of urine specimens are
being rejected because of improper collection.
c. A key statement is missing from the Clinitest
procedure.
d. Open control bottles in the refrigerator are examined.
2. As the new supervisor of the urinalysis section, you
encounter the following situations. Explain whether
you would accept them or take corrective action.
a. You are told that the supervisor always performs
the CAP proficiency survey.
b. QC is not performed daily on the reagent strips.
c. The urinalysis section is primarily staffed by
personnel assigned to other departments for whom
you have no personnel data.
3. The medical technologist was assigned to test 10 urine
specimens chemically. She removed 10 strips from the
container and proceeded with testing. Several patients’
urine indicated a trace positive glucose in the urine.
She then opened a new bottle of reagent dipsticks and
proceeded to perform the QC. The negative control
also tested as a trace positive for glucose. The medical
technologist consulted the supervisor. The supervisor
ran the QC and the results were in the correct range.
After observing the medical technologist’s technique,
the supervisor realized that the medical technologist
was waiting too long to read the glucose results and
therefore reporting erroneous results.
a. What is wrong with this scenario?
b. Who should run the QC for each test? Why?
c. When should controls be run?
d. What do you do when the QC is out of range?
e. When can you report patient results?
3920_Ch01_002-026 23/01/14 9:20 AM Page 25
Chapter 1 | Safety and Quality Assessment
4. An outpatient urine specimen was delivered to the
laboratory at 0800 and placed on the counter in the
Urinalysis department. The medical laboratory scientist
performed urinalysis on the specimen at 1130. The
following results were abnormal:
Clarity: Cloudy
pH: 9.0
Nitrite: Positive
The patient was a known diabetic; however, the
glucose result was negative.
a. What could be a possible cause for the abnormal
results?
25
b. Where would the information concerning what
should have been done with this specimen be
found and the criteria for rejection?
c. What QA procedure may have detected this error?
d. What form will need to be completed for this
scenario?
e. How might this affect this patient’s care?
f. How will the corrected results be documented?
3920_Ch01_002-026 23/01/14 9:20 AM Page 26
3920_Ch02_027-038 23/01/14 10:08 AM Page 27
CHAPTER
2
Introduction to Urinalysis
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
2-1 List three major organic and three major inorganic
chemical constituents of urine.
2-8 Discuss the actions of bacteria on an unpreserved urine
specimen.
2-2 Describe a method for determining whether a
questionable fluid is urine.
2-9 Briefly discuss five methods for preserving urine specimens, including their advantages and disadvantages.
2-3 Recognize normal and abnormal daily urine volumes.
2-4 Describe the characteristics of the recommended urine
specimen containers.
2-5 Describe the correct methodology for labeling urine
specimens.
2-6 State four possible reasons a laboratory would reject a
urine specimen.
2-7 List 10 changes that may take place in a urine specimen that remains at room temperature for more
than 2 hours.
2-10 Instruct a patient in the correct procedure for collecting the following specimens: random, first morning,
24-hour timed, catheterized, midstream clean-catch,
suprapubic aspiration, three-glass collection, and
pediatric. Identify a diagnostic use for each collection
technique.
2-11 Describe the type of specimen needed for optimal
results when a specific urinalysis procedure is
requested.
KEY TERMS
Albuminuria
First morning specimen
Polyuria
Anuria
Midstream clean-catch specimen
Suprapubic aspiration
Catheterized specimen
Nocturia
Timed specimen
Chain of custody (COC)
Oliguria
3920_Ch02_027-038 23/01/14 10:08 AM Page 28
28
Part One | Background
History and Importance
Analyzing urine was actually the beginning of laboratory medicine. References to the study of urine can be found in the
drawings of cavemen and in Egyptian hieroglyphics, such as
the Edwin Smith Surgical Papyrus. Pictures of early physicians
commonly showed them examining a bladder-shaped flask of
urine (Fig. 2–1). Often these physicians never saw the patient,
only the patient’s urine. Although these physicians lacked the
sophisticated testing mechanisms now available, they were
able to obtain diagnostic information from such basic observations as color, turbidity, odor, volume, viscosity, and even
sweetness (by noting that certain specimens attracted ants
or tasted sweet). These same urine characteristics are still
reported by laboratory personnel. However, modern urinalysis
has expanded beyond physical examination of urine to
include chemical analysis and microscopic examination of
urinary sediment.
Many well-known names in the history of medicine are
associated with the study of urine, including Hippocrates, who,
in the 5th century BCE, wrote a book on “uroscopy.” During
the Middle Ages, physicians concentrated their efforts very intensively on the art of uroscopy, receiving instruction in urine
examination as part of their training (Fig. 2–2). By 1140 CE,
color charts had been developed that described the significance
of 20 different colors (Fig. 2–3). Chemical testing progressed
from “ant testing” and “taste testing” for glucose to Frederik
Dekkers’ discovery in 1694 of albuminuria by boiling urine.1
Figure 2–2 Instruction in urine examination. (Courtesy of National
Library of Medicine.)
Figure 2–1 Physician examines urine flask. (Courtesy of National Library of Medicine.)
The credibility of urinalysis became compromised when
charlatans without medical credentials began offering their predictions to the public for a healthy fee. These charlatans, called
“pisse prophets,” became the subject of a book published by
Thomas Bryant in 1627. The revelations in this book inspired
the passing of the first medical licensure laws in England—
another contribution of urinalysis to the field of medicine.
The invention of the microscope in the 17th century led
to the examination of urinary sediment and to the development
by Thomas Addis of methods for quantitating the microscopic
sediment. Richard Bright introduced the concept of urinalysis
as part of a doctor’s routine patient examination in 1827. By
the 1930s, however, the number and complexity of the tests
performed in a urinalysis had reached a point of impracticality,
and urinalysis began to disappear from routine examinations.
Fortunately, development of modern testing techniques rescued routine urinalysis, which has remained an integral part
of the patient examination.
Two unique characteristics of a urine specimen account
for this continued popularity:
1. Urine is a readily available and easily collected
specimen.
3920_Ch02_027-038 23/01/14 10:08 AM Page 29
Chapter 2 | Introduction to Urinalysis 29
Urea, a metabolic waste product produced in the liver from
the breakdown of protein and amino acids, accounts for nearly
half of the total dissolved solids in urine. Other organic substances include primarily creatinine and uric acid. The major inorganic solid dissolved in urine is chloride, followed by sodium
and potassium. Small or trace amounts of many additional inorganic chemicals are also present in urine (Table 2–1). Dietary
intake greatly influences the concentrations of these inorganic
compounds, making it difficult to establish normal levels. Other
substances found in urine include hormones, vitamins, and
medications. Although not a part of the original plasma filtrate,
the urine also may contain formed elements, such as cells, casts,
crystals, mucus, and bacteria. Increased amounts of these formed
elements are often indicative of disease.
Urine Volume
Urine volume depends on the amount of water that the kidneys
excrete. Water is a major body constituent; therefore, the
amount excreted is usually determined by the body’s state of
Figure 2–3 A chart used for urine analysis. (Courtesy of National
Library of Medicine.)
2. Urine contains information, which can be obtained by
inexpensive laboratory tests, about many of the body’s
major metabolic functions.
These characteristics fit in well with the current trends
toward preventive medicine and lower medical costs. In fact,
the Clinical and Laboratory Standards Institute (CLSI) defines urinalysis as “the testing of urine with procedures commonly performed in an expeditious, reliable, accurate, safe,
and cost-effective manner.” Reasons for performing urinalysis
identified by CLSI include aiding in the diagnosis of disease,
screening asymptomatic populations for undetected disorders, and monitoring the progress of disease and the effectiveness of therapy.2
Urine Formation
The kidneys continuously form urine as an ultrafiltrate of
plasma. Reabsorption of water and filtered substances essential
to body function converts approximately 170,000 mL of
filtered plasma to the average daily urine output of 1200 mL.
(Refer to Chapter 3.)
Urine Composition
In general, urine consists of urea and other organic and inorganic chemicals dissolved in water. Urine is normally 95%
water and 5% solutes, although considerable variations in the
concentrations of these solutes can occur owing to the influence of factors such as dietary intake, physical activity, body
metabolism, and endocrine functions.
TECHNICAL TIP Should it be necessary to determine
whether a particular fluid is urine, the specimen can be
tested for its urea and creatinine content. Because both
these substances are present in much higher concentrations in urine than in other body fluids, a high urea and
creatinine content can identify a fluid as urine.
Table 2–1
Primary Components in Normal Urine3
Component
Comment
Urea
Primary organic component. Product
of protein and amino acid
metabolism
Product of creatine metabolism by
muscles
Product of nucleic acid breakdown in
food and cells
Primary inorganic component. Found
in combination with sodium (table
salt) and many other inorganic
substances
Primarily from salt, varies by intake
Combined with chloride and other
salts
Combines with sodium to buffer the
blood
Regulates blood and tissue fluid
acidity
Combines with chloride, sulfate, and
phosphate
Creatinine
Uric acid
Chloride
Sodium
Potassium
Phosphate
Ammonium
Calcium
3920_Ch02_027-038 23/01/14 10:08 AM Page 30
30
Part One | Background
hydration. Factors that influence urine volume include fluid
intake, fluid loss from nonrenal sources, variations in the secretion of antidiuretic hormone, and need to excrete increased
amounts of dissolved solids, such as glucose or salts. Taking
these factors into consideration, although the normal daily
urine output is usually 1200 to 1500 mL, a range of 600 to
2000 mL is considered normal.
Oliguria, a decrease in urine output (which is less
than 1 mL/kg/hr in infants, less than 0.5 mL/kg/hr in
children, and less than 400 mL/day in adults), is commonly
seen when the body enters a state of dehydration as a result
of excessive water loss from vomiting, diarrhea, perspiration,
or severe burns.
Oliguria leading to anuria, cessation of urine flow, may
result from any serious damage to the kidneys or from a
decrease in the flow of blood to the kidneys.
The kidneys excrete two to three times more urine during
the day than during the night. An increase in the nocturnal excretion of urine is termed nocturia. Polyuria, an increase in
daily urine volume (greater than 2.5 L/day in adults and 2.5
to 3 mL/kg/day in children), is often associated with diabetes
mellitus and diabetes insipidus; however, it may be artificially
induced by diuretics, caffeine, or alcohol, all of which suppress
the secretion of antidiuretic hormone.
Diabetes mellitus and diabetes insipidus produce polyuria
for different reasons, and analysis of the urine is an important
step in the differential diagnosis (Fig. 2–4). Diabetes mellitus
is caused by a defect either in the pancreatic production of insulin or in the function of insulin, which results in an increased
body glucose concentration. The kidneys do not reabsorb excess glucose, necessitating excretion of increased amounts of
water to remove the dissolved glucose from the body. Although
appearing to be dilute, a urine specimen from a patient with
Polydipsia
Polyuria
Specific gravity
Decreased SG
Increased SG
Decreased production
or
Function of ADH
Decreased insulin
or
Decreased function
of insulin
Diabetes insipidus
Increased glucose
Diabetes mellitus
Figure 2–4 Differentiation between diabetes mellitus and diabetes
insipidus.
diabetes mellitus has a high specific gravity because of the increased glucose content.
Diabetes insipidus results from a decrease in the production or function of antidiuretic hormone (ADH); thus, the
water necessary for adequate body hydration is not reabsorbed
from the plasma filtrate. In this condition, the urine is truly dilute and has a low specific gravity. Fluid loss in both diseases
is compensated by increased ingestion of water (polydipsia),
producing an even greater urine volume. Polyuria accompanied by increased fluid intake is often the first symptom of
either disease.
Specimen Collection
As discussed in Chapter 1, urine is a biohazardous substance
that requires the observance of Standard Precautions.
Gloves should be worn at all times when in contact with
the specimen.
Containers
Specimens must be collected in clean, dry, leak-proof containers. Disposable containers should be used because they eliminate the chance of contamination owing to improper washing.
These disposable containers are available in a variety of sizes
and shapes, including bags with adhesive for the collection of
pediatric specimens and large containers for 24-hour specimens. Properly applied screw-top lids are less likely to leak
than are snap-on lids.
Containers for routine urinalysis should have a wide
mouth to facilitate collections from female patients and a wide,
flat bottom to prevent overturning. They should be made of a
clear material to allow for determination of color and clarity.
The recommended capacity of the container is 50 mL, which
allows 12 mL of specimen needed for microscopic analysis,
additional specimen for repeat analysis, and enough room for
the specimen to be mixed by swirling the container.
Individually packaged sterile containers with secure
closures should be used for microbiologic urine studies. Sterile
containers are also suggested if more than 2 hours elapse
between specimen collection and analysis.2
Specially designed sterile containers are available that
have a lid with a transfer device that can be assessed with a
device called a transfer straw. The transfer straw has a needle
and an evacuated tube holder. Urine can be sterilely transferred to tubes containing preservatives for microbiology testing and tubes with conical bottoms for sediment analysis or
round bottoms for automated reagent strip testing.4 Additional
information and pictures can be found at http//www.
bd.com/ds/productCenter/.
Labels
All specimens must be labeled properly with the patient’s name
and identification number, the date and time of collection, and
additional information such as the patient’s age and location
and the healthcare provider’s name, as required by institutional
protocol. Labels must be attached to the container, not to the
3920_Ch02_027-038 23/01/14 10:08 AM Page 31
Chapter 2 | Introduction to Urinalysis 31
Specimen Handling
lid, and should not become detached if the container is refrigerated or frozen.
Requisitions
A requisition form (manual or computerized) must accompany
specimens delivered to the laboratory. The information on the
form must match the information on the specimen label.
Additional information on the form can include method of collection or type of specimen, possible interfering medications,
and the patient’s clinical information. The time the specimen
is received in the laboratory should be recorded on the form.
Specimen Rejection
Improperly labeled and collected specimens should be rejected by the laboratory, and appropriate personnel should
be notified to collect a new specimen. Unacceptable situations include:
1. Specimens in unlabeled containers
2. Nonmatching labels and requisition forms
3. Specimens contaminated with feces or toilet paper
4. Containers with contaminated exteriors
5. Specimens of insufficient quantity
6. Specimens that have been improperly transported
Laboratories should have a written policy detailing their
conditions for specimen rejection.
TECHNICAL TIP Never discard a specimen before
checking with a supervisor.
Table 2–2
The fact that a urine specimen is so readily available and easily
collected often leads to laxity in the treatment of the specimen
after its collection. Changes in urine composition take place
not only in vivo but also in vitro, thus requiring correct handling procedures.
Specimen Integrity
Following collection, specimens should be delivered to the laboratory promptly and tested within 2 hours. A specimen that
cannot be delivered and tested within 2 hours should be refrigerated or have an appropriate chemical preservative added.
Table 2–2 describes the 11 most significant changes that may
occur in a specimen allowed to remain unpreserved at room
temperature for longer than 2 hours. Notice that most of the
changes are related to the presence and growth of bacteria.
These variations are discussed again under the individual test
procedures. At this point it is important to realize that improper
preservation can seriously affect the results of a routine urinalysis.
Specimen Preservation
The most routinely used method of preservation is refrigeration
at 2°C to 8°C, which decreases bacterial growth and metabolism. If the urine is to be cultured, it should be refrigerated
during transit and kept refrigerated until cultured up to
24 hours.2 The specimen must return to room temperature
before chemical testing by reagent strips.
When a specimen must be transported over a long distance and refrigeration is impossible, chemical preservatives
may be added. Commercially prepared transport tubes are
available. The ideal preservative should be bactericidal, inhibit
urease, and preserve formed elements in the sediment. At the
Changes in Unpreserved Urine
Analyte
Change
Cause
Color
Clarity
Odor
pH
Modified/darkened
Decreased
Increased
Increased
Glucose
Ketones
Bilirubin
Urobilinogen
Nitrite
Red and white blood
cells and casts
Bacteria
Trichomonas
Decreased
Decreased
Decreased
Decreased
Increased
Decreased
Oxidation or reduction of metabolites
Bacterial growth and precipitation of amorphous material
Bacterial multiplication causing breakdown of urea to ammonia
Breakdown of urea to ammonia by urease-producing bacteria/loss
of CO2
Glycolysis and bacterial use
Volatilization and bacterial metabolism
Exposure to light/photo oxidation to biliverdin
Oxidation to urobilin
Multiplication of nitrate-reducing bacteria
Disintegration in dilute alkaline urine
Increased
Decreased
Multiplication
Loss of motility, death
3920_Ch02_027-038 23/01/14 10:08 AM Page 32
32
Part One | Background
TECHNICAL TIP Specimens must be returned to room
temperature before chemical testing by reagent strips
because the enzyme reactions on the strips perform best
at room temperature.
same time, the preservative should not interfere with chemical
tests. Unfortunately, as can be seen in Table 2–3, the ideal
preservative does not exist; therefore, a preservative that best
suits the needs of the required analysis should be chosen.
TECHNICAL TIP When preserving samples that will be
transported to another laboratory, be sure to check with
that laboratory concerning the appropriate preservative.
Table 2–3
Types of Specimens
To obtain a specimen that is representative of a patient’s metabolic state, regulation of certain aspects of specimen collection
is often necessary. These special conditions may include time,
length, and method of collection and the patient’s dietary and
medicinal intake. It is important to instruct patients when they
must follow special collection procedures. Frequently encountered specimens are listed in Table 2–4.
Random Specimen
This is the most commonly received specimen because of
its ease of collection and convenience for the patient. The
random specimen may be collected at any time, but the actual time of voiding should be recorded on the container.2
The random specimen is useful for routine screening tests to
Urine Preservatives
Preservatives
Advantages
Disadvantages
Additional Information
Refrigeration
Does not interfere with
chemical tests
Prevents bacterial growth and
metabolism
Precipitates amorphous
phosphates and urates
Interferes with drug and
hormone analyses
Formalin (formaldehyde)
Excellent sediment preservative
Sodium fluoride
Is a good preservative for drug
analyses
Commercial preservative
tablets
Yellow UA Plus tube
Convenient when refrigeration
not possible
Have controlled concentration
to minimize interference
Contains collection cup,
transfer straw, culture and
sensitivity (C&S) preservative tube, or UA tube
Sample stable at room temperature (RT) for 48 hours; prevents bacterial growth and
metabolism
Use on automated instruments
Acts as a reducing agent,
interfering with chemical
tests for glucose, blood,
leukocyte esterase, and
copper reduction
Inhibits reagent strip tests
for glucose, blood, and
leukocytes
Check tablet composition
to determine possible
effects on desired tests
Prevents bacterial growth
for 24 hours2
Keeps pH at about 6.0
Can be used for urine
culture transport
Rinse specimen container
with formalin to preserve
cells and casts
Cherry red/yellow
Preservative Plus tube
Stable for 72 hours at RT; instrument-compatible
Boric acid
Urine Collection Kits4
(Becton, Dickinson,
Rutherford, NJ)
Light gray and gray C&S
tube
Do not use if urine is below
minimum fill line
Must refrigerate within
2 hours
Must be filled to minimum
fill line.
Bilirubin and urobilinogen
may be decreased if
specimen is exposed to
light and left at RT
Preservative is boric acid,
sodium borate and
sodium formate.
Keeps pH at about 6.0
Round or conical bottom,
no preservative
Preservative is sodium propionate, ethyl paraben,
and chlorhexidine;
round or conical bottoms
3920_Ch02_027-038 23/01/14 10:08 AM Page 33
Chapter 2 | Introduction to Urinalysis 33
Table 2–4
Types of Urine Specimens
Type of Specimen
Purpose
Random
First morning
Routine screening
Routine screening
Pregnancy tests
Orthostatic protein
Quantitative chemical tests
Bacterial culture
Routine screening
Bacterial culture
Bladder urine for bacterial
culture
Cytology
Prostatic infection
24-hour (or timed)
Catheterized
Midstream clean-catch
Suprapubic aspiration
Three-glass collection
detect obvious abnormalities. However, it may also show
erroneous results resulting from dietary intake or physical
activity just before collection. The patient will then be
requested to collect an additional specimen under more
controlled conditions.
First Morning Specimen
Although it may require the patient to make an additional
trip to the laboratory, this is the ideal screening specimen. It
is also essential for preventing false-negative pregnancy tests
and for evaluating orthostatic proteinuria. The first morning specimen is a concentrated specimen, thereby assuring
detection of chemicals and formed elements that may not be
present in a dilute random specimen. The patient should be
instructed to collect the specimen immediately on arising
and to deliver it to the laboratory within 2 hours or keep it
refrigerated.
HISTORICAL NOTE
Glucose Tolerance Specimens
Glucose tolerance specimens are sometimes collected
to correspond with the blood samples drawn during a
glucose tolerance test (GTT). The number of specimens
varies with the length of the test. GTTs may include
fasting, half-hour, 1-hour, 2-hour, and 3-hour specimens,
and possibly 4-hour, 5-hour, and 6-hour specimens. The
urine is tested for glucose and ketones, and the results are
reported along with the blood test results as an aid to interpreting the patient’s ability to metabolize a measured
amount of glucose and are correlated with the renal
threshold for glucose. Collection of these specimens is an
institutional option.5
24-Hour (or Timed) Specimen
Measuring the exact amount of a urine chemical is often
necessary instead of just reporting its presence or absence. A
carefully timed specimen must be used to produce accurate
quantitative results. Many solutes exhibit diurnal variations
such as catecholamines, 17-hydroxysteroids, and electrolytes
in which the lowest concentration is in the early morning and
the highest concentration occurs in the afternoon.2 When the
concentration of the substance to be measured changes with
diurnal variations and with daily activities such as exercise,
meals, and body metabolism, 24-hour collection is required.
If the concentration of a particular substance remains constant,
the specimen may be collected over a shorter period. Care
must be taken, however, to keep the patient adequately
hydrated during short collection periods. Patients must be
instructed on the procedure for collecting a timed specimen.
To obtain an accurate timed specimen, the patient must
begin and end the collection period with an empty bladder. The
concentration of a substance in a particular period must be
calculated from the urine volume produced during that time.
On its arrival in the laboratory, a 24-hour specimen must
be thoroughly mixed and the volume accurately measured and
recorded. If only an aliquot is needed for testing, the amount
saved must be adequate to permit repeat or additional testing.
If a specimen is collected in two containers, the contents of
the containers should be combined and thoroughly mixed
before aliquoting. Consideration also must be given to the
preservation of specimens collected over extended periods.
All specimens should be refrigerated or kept on ice during the
collection period and may also require addition of a chemical
PROCEDURE 2-1
Sample 24-Hour (Timed) Specimen Collection
Procedure
Provide the patient with written instructions, and explain
the collection procedure.
Provide the patient with the proper collection container
and preservative.
Day 1: 7 a.m.: patient voids and discards specimen;
collects all urine for the next 24 hours.
Day 2: 7 a.m.: patient voids and adds this urine to
previously collected urine.
On arrival at laboratory, the entire 24-hour specimen is
thoroughly mixed, and the volume is measured and
recorded.
TECHNICAL TIP Addition of urine formed before the
start of the collection period will falsely elevate results and
failure to include urine produced at the end of the collection period will falsely decrease results.
3920_Ch02_027-038 23/01/14 10:08 AM Page 34
34
Part One | Background
preservative. The preservative chosen must be nontoxic to the
patient and should not interfere with the tests to be performed.
Appropriate collection information is included with test procedures and should be read before issuing a container and
instructions to the patient.
Catheterized Specimen
This specimen is collected under sterile conditions by passing
a hollow tube (catheter) through the urethra into the bladder.
The most commonly requested test on a catheterized specimen is a bacterial culture.
Midstream Clean-Catch Specimen
As an alternative to the catheterized specimen, the midstream
clean-catch specimen provides a safer, less traumatic method
for obtaining urine for bacterial culture and routine urinalysis.
It provides a specimen that is less contaminated by epithelial
cells and bacteria and, therefore, is more representative of the
actual urine than the routinely voided specimen. Patients must
be provided with appropriate cleansing materials, a sterile
container, and instructions for cleansing and voiding. Strong
bacterial agents, such as hexachlorophene or povidone-iodine,
should not be used as cleansing agents. Mild antiseptic towelettes are recommended. Some urine collection transfer kits
contain Castile Soap Towelettes.
PROCEDURE 2-2
Clean-Catch Specimen Collection: Female
Cleansing Procedure2
1. Wash hands.
2. Remove the lid from the container without touching
the inside of the container or lid.
3. Separate the skin folds (labia).
4. Cleanse from front to back on either side of the
urinary opening with an antiseptic towelette, using
a clean one for each side.
5. Hold the skin folds apart and begin to void into the
toilet.
6. Bring the urine container into the stream of urine and
collect an adequate amount of urine. Do not touch
the inside of the container or allow the container to
touch the genital area.
7. Finish voiding into the toilet.
8. Cover the specimen with the lid. Touch only the
outside of the lid and container.
9. Label the container with the name and time of
collection and place in the specified area or follow
institutional policy.
Suprapubic Aspiration
Occasionally urine may be collected by external introduction
of a needle through the abdomen into the bladder. Because the
bladder is sterile under normal conditions, suprapubic aspiration provides a sample for bacterial culture that is completely
free of extraneous contamination. The specimen can also be
used for cytologic examination.
Prostatitis Specimen
Several methods are available to detect the presence of prostatitis.
Three-Glass Collection
Prior to collection the area is cleansed using the male midstream clean-catch procedure. Then instead of discarding the
first urine passed, it is collected in a sterile container. Next, the
midstream portion is collected in another sterile container. The
prostate is then massaged so that prostate fluid will be passed
with the remaining urine into a third sterile container. Quantitative cultures are performed on all specimens, and the first
TECHNICAL TIP When both a routine urinalysis and a
culture are requested on a catheterized or midstream
collection, the culture should be performed first to prevent
contamination of the specimen. A collection transfer kit
can also be used.
PROCEDURE 2-3
Clean-Catch Specimen Collection: Male
Cleansing Procedure2
1. Wash hands.
2. Remove the lid from the sterile container without
touching the inside of the container or lid.
3. Cleanse the tip of the penis with antiseptic
towelette and let dry. Retract the foreskin if
uncircumcised.
4. Void into the toilet. Hold back foreskin if
necessary.
5. Bring the sterile urine container into the stream of
urine and collect an adequate amount of urine. Do
not touch the inside of the container or allow the
container to touch the genital area.
6. Finish voiding into the toilet.
7. Cover the specimen with the lid. Touch only the
outside of the lid and container.
8. Label the container with the name and time of
collection and place in the specified area or follow
institutional policy.
3920_Ch02_027-038 23/01/14 10:08 AM Page 35
Chapter 2 | Introduction to Urinalysis 35
and third specimens are examined microscopically. In prostatic
infection, the third specimen will have a white blood cell/
high-power field count and a bacterial count 10 times that of
the first specimen. Macrophages containing lipids may also be
present. The second specimen is used as a control for bladder
and kidney infection. If it is positive, the results from the third
specimen are invalid because infected urine has contaminated
the specimen.6
Pre- and Post-Massage Test
In the pre- and post-massage test (PPMT), a clean-catch midstream urine specimen is collected. A second urine sample is
collected after the prostate is massaged. A positive result is significant bacteriuria in the post-massage specimen of greater
than 10 times the premassage count.7
Pediatric Specimens
Collection of pediatric specimens can present a challenge. Soft,
clear plastic bags with hypoallergenic skin adhesive to attach
to the genital area of both boys and girls are available for collecting routine specimens. Sterile specimens may be obtained
by catheterization or by suprapubic aspiration. Care must be
taken not to touch the inside of the bag when applying it.
For routine specimen analysis ensure the area is free of
contamination. Attach the bag firmly over the genital area
avoiding the anus. When enough specimen has been collected,
remove the bag and label it or pour the specimen into container and label the container following institutional policy.
For microbiology specimens clean the area with soap and
water and sterilely dry the area, removing any residual soap
residue. Firmly apply a sterile bag. Sterilely transfer collected
specimen into a sterile container and label the container.2
HISTORICAL NOTE
Stamey-Mears Test for Prostatitis
The four-glass method consists of bacterial cultures of the
initial voided urine (VB1), midstream urine (VB2), expressed prostatic secretions (EPS), and a post-prostatic
massage urine specimen (VB3). Urethral infection or inflammation is tested for by the VB1, and the VB2 tests for
urinary bladder infection. The prostatic secretions are cultured and examined for white blood cells. Having more
than 10 to 20 white blood cells per high-power field is
considered abnormal.7
TECHNICAL TIP Check the applied bags approximately
every 15 minutes until the needed amount of sample has
been collected.
Drug Specimen Collection
Urine specimen collection is the most vulnerable part of
a drug-testing program. Correct collection procedures and
documentation are necessary to ensure that the results are
those of the specific individual submitting the specimen. The
chain of custody (COC) is the process that provides this documentation of proper sample identification from the time of
collection to the receipt of laboratory results. The COC is a
standardized form that must document and accompany every
step of drug testing, from collector to courier to laboratory to
medical review officer to employer.
For urine specimens to withstand legal scrutiny, it is
necessary to prove that no tampering of the specimen occurred, such as substitution, adulteration, or dilution. All
personnel handling the specimen must be noted. The specimen must be handled securely, with a guarantee that no
unauthorized access to the specimen was possible. Proper
identification of the individual whose information is indicated on the label is required. Either photo identification or
positive identification by an employer representative with
photo ID is acceptable.
Urine specimen collections may be “witnessed” or “unwitnessed.” The decision to obtain a witnessed collection is
indicated when it is suspected that the donor may alter or
substitute the specimen or it is the policy of the client ordering the test. If a witnessed specimen collection is ordered, a
same-gender collector will observe the collection of 30 to
45 mL of urine. Witnessed and unwitnessed collections
should be immediately handed to the collector.
The urine temperature must be taken within 4 minutes
from the time of collection to confirm the specimen has not
been adulterated. The temperature should read within the
range of 32.5°C to 37.7°C. If the specimen temperature is
not within range, the temperature should be recorded and
the supervisor or employer contacted immediately. Urine
temperatures outside of the recommended range may indicate
specimen contamination. Recollection of a second specimen
as soon as possible will be necessary. The urine color is
also inspected to identify any signs of contaminants. The
specimen is labeled, packaged, and transported following
laboratory-specific instructions.
3920_Ch02_027-038 23/01/14 10:08 AM Page 36
36
Part One | Background
PROCEDURE 2-4
Urine Drug Specimen Collection Procedure
1. The collector washes hands and wears gloves.
2. The collector adds bluing agent (dye) to the toilet
water reservoir to prevent an adulterated specimen.
3. The collector eliminates any source of water other
than toilet by taping the toilet lid and faucet handles.
4. The donor provides photo identification or positive
identification from employer representative.
5. The collector completes step 1 of the chain-of-custody
(COC) form and has the donor sign the form.
6. The donor leaves his or her coat, briefcase, and/or
purse outside the collection area to avoid the possibility of concealed substances contaminating the urine.
7. The donor washes his or her hands and receives a
specimen cup.
8. The collector remains in the restroom but outside the
stall, listening for unauthorized water use, unless a
witnessed collection is requested.
9. The donor hands specimen cup to the collector.
Transfer is documented.
10. The collector checks the urine for abnormal color and
for the required amount (30 to 45 mL).
11. The collector checks that the temperature strip on the
specimen cup reads 32.5°C to 37.7°C. The collector
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Herman, JR: Urology: A View Through the Retrospectroscope.
Harper & Row, Hagerstown, MD, 1973.
2. Clinical and Laboratory Standards Institute (formerly NCCLS),
Approved Guideline GP16-A3: Urinalysis and Collection,
Transportation, and Preservation of Urine Specimens; Approved
Guideline—ed 3, CLSI, Wayne, PA, 2009.
12.
13.
14.
15.
16.
17.
18.
19.
20.
records the in-range temperature on the COC form
(COC step 2). If the specimen temperature is out of
range or the specimen is suspected of having been
diluted or adulterated, a new specimen must be
collected and a supervisor notified.
The specimen must remain in the sight of the donor and
collector at all times.
With the donor watching, the collector peels off the
specimen identification strips from the COC form (COC
step 3) and puts them on the capped bottle, covering
both sides of the cap.
The donor initials the specimen bottle seals.
The date and time are written on the seals.
The donor completes step 4 on the COC form.
The collector completes step 5 on the COC form.
Each time the specimen is handled, transferred,
or placed in storage, every individual must be
identified and the date and purpose of the change
recorded.
The collector follows laboratory-specific instructions for
packaging the specimen bottles and laboratory copies of
the COC form.
The collector distributes the COC copies to appropriate
personnel.
3. Torora, GJ, and Anagnostakos, NP: Principles of Anatomy
and Physiology, ed 6, Harper & Row, New York, 1990,
p. 51.
4. Becton, Dickinson and Company: BD Vacutainer Urine Products
for collection, storage, and transport of urine specimens. Product
Circular, 2011.
5. Baer, DM: Glucose tolerance test: Tips from the clinical experts.
Medical Laboratory Observer, Sept. 2003.
6. Rous, SN: The Prostate Book. Consumers Union, Mt. Vernon,
NY, 1988.
7. Stevermer, JJ, and Easley, SK: Treatment of prostatitis. Am Fam
Physician 61(10), 2000.
Study Questions
1. The average daily output of urine is:
A. 200 mL
B. 500 mL
C. 1200 mL
D. 2500 mL
2. An unidentified fluid is received in the laboratory with a
request to determine whether the fluid is urine or another
body fluid. Using routine laboratory tests, what tests
would determine that the fluid is most probably urine?
A. Glucose and ketones
B. Urea and creatinine
C. Uric acid and amino acids
D. Protein and amino acids
3920_Ch02_027-038 23/01/14 10:08 AM Page 37
Chapter 2 | Introduction to Urinalysis 37
3. The primary inorganic substance found in urine is:
A. Sodium
B. Phosphate
C. Chloride
D. Calcium
4. A patient presenting with polyuria, nocturia, polydipsia,
and a low urine specific gravity is exhibiting symptoms of:
A. Diabetes insipidus
B. Diabetes mellitus
C. Urinary tract infection
D. Uremia
5. A patient with oliguria might progress to having:
A. Nocturia
B. Polyuria
C. Polydipsia
D. Anuria
6. All of the following are characteristics of recommended
urine containers except:
A. A flat bottom
B. A capacity of 50 mL
C. A snap-on lid
D. Are disposable
7. Labels for urine containers are:
A. Attached to the container
B. Attached to the lid
C. Placed on the container prior to collection
D. Not detachable
8. A urine specimen may be rejected by the laboratory for
all of the following reasons except the fact that the:
A. Requisition states the specimen is catheterized
B. Specimen contains toilet paper
C. Label and requisition do not match
D. Outside of the container has fecal material
contamination
9. A cloudy specimen received in the laboratory may have
been preserved using:
A. Boric acid
B. Chloroform
C. Refrigeration
D. Formalin
10. For general screening the most frequently collected
specimen is a:
A. Random one
B. First morning
C. Midstream clean-catch
D. Timed
11. The primary advantage of a first morning specimen over
a random specimen is that it:
A. Is less contaminated
B. Is more concentrated
C. Is less concentrated
D. Has a higher volume
12. If a routine urinalysis and a culture are requested on a
catheterized specimen, then:
A. Two separate containers must be collected
B. The routine urinalysis is performed first
C. The patient must be recatheterized
D. The culture is performed first
13. If a patient fails to discard the first specimen when
collecting a timed specimen the:
A. Specimen must be recollected
B. Results will be falsely elevated
C. Results will be falsely decreased
D. Both A and B
14. The primary cause of unsatisfactory results in an unpreserved routine specimen not tested for 8 hours is:
A. Bacterial growth
B. Glycolysis
C. Decreased pH
D. Chemical oxidation
15. Prolonged exposure of a preserved urine specimen to
light will cause:
A. Decreased glucose
B. Increased cells and casts
C. Decreased bilirubin
D. Increased bacteria
16. Which of the following would be least affected in a
specimen that has remained unpreserved at room
temperature for more than 2 hours?
A. Urobilinogen
B. Ketones
C. Protein
D. Nitrite
17. Bacterial growth in an unpreserved specimen will:
A. Decrease clarity
B. Increase bilirubin
C. Decrease pH
D. Increase glucose
18. The most sterile specimen collected is a:
A. Catheterized
B. Midstream clean-catch
C. Three-glass
D. Suprapubic aspiration
3920_Ch02_027-038 23/01/14 10:08 AM Page 38
38
Part One | Background
19. Which of the following would not be given to a patient
prior to the collection of a midstream clean-catch specimen?
A. Sterile container
B. Iodine cleanser
C. Antiseptic towelette
D. Instructions
20. Urine specimen collection for drug testing requires the
collector to do all of the following except:
A. Inspect the specimen color
B. Perform reagent strip testing
C. Read the specimen temperature
D. Fill out a chain-of-custody form
Case Studies and Clinical Situations
1. A patient brings a first morning specimen to the
laboratory at 1:00 p.m.
a. How could this affect the urinalysis results?
b. What could the patient say that would make the
specimen satisfactory for testing?
2. A patient collecting a midstream clean-catch specimen
voids immediately into the container.
a. How could this affect the clarity of the specimen?
b. How could this affect the microscopic examination?
3. A patient brings a 24-hour timed specimen to the
laboratory and reports that he or she forgot to collect
a specimen voided during the night.
a. How will this affect the results of a quantitative test
for creatinine?
b. What should the patient be told to do?
4. You receive a urine preservative tube for culture
containing a volume of specimen that is considerably
below the minimum fill line.
a. Could this affect the culture?
b. Why?
5. A worker suspects that he or she will be requested to
collect an unwitnessed urine specimen for drug analysis.
He or she carries a substitute specimen in his or her
pocket for 2 days before being told to collect the specimen. Shortly after the worker delivers the specimen to
the collector, he or she is instructed to collect another
specimen.
a. What test was performed on the specimen to
determine possible specimen manipulation?
b. How was the specimen in this situation affected?
c. If a specimen for drug analysis tests positive, state a
possible defense related to specimen collection and
handling that an attorney might employ.
d. How can this defense be avoided?
3920_Ch03_039-057 23/01/14 10:10 AM Page 39
CHAPTER
3
Renal Function
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
3-1 Identify the components of the nephron, kidney, and
excretory system.
3-10 Given hypothetical laboratory data, calculate a creatinine
clearance and determine whether the result is normal.
3-2 Trace the flow of blood through the nephron and state
the physiologic functions that occur.
3-11 Discuss the clinical significance of the glomerular
filtration rate tests.
3-3 Describe the process of glomerular ultrafiltration.
3-12 Describe and contrast the MDRD, cystatin C, and
beta2-microglobulin tests for performing estimated
glomerular filtration rates (eGFR).
3-4 Discuss the functions and regulation of the reninangiotensin-aldosterone system.
3-5 Differentiate between active and passive transport in
relation to renal concentration.
3-6 Explain the function of antidiuretic hormone in the
concentration of urine.
3-7 Describe the role of tubular secretion in maintaining
acid–base balance.
3-8 Identify the laboratory procedures used to evaluate
glomerular filtration, tubular reabsorption and secretion, and renal blood flow.
3-9 Describe the creatinine clearance test.
3-13 Define osmolarity and discuss its relationship to urine
concentration.
3-14 Describe the basic principles of freezing point
osmometers.
3-15 Given hypothetic laboratory data, calculate a freewater clearance and interpret the result.
3-16 Given hypothetic laboratory data, calculate a PAH
clearance and relate this result to renal blood flow.
3-17 Describe the relationship of urinary ammonia and
titratable acidity to the production of an acidic urine.
KEY TERMS
Active transport
Glomerular filtration barrier
Renal plasma flow
Afferent arteriole
Glomerular filtration rate (GFR)
Renal threshold
Aldosterone
Glomerulus
Renin
Antidiuretic hormone (ADH)
Juxtaglomerular apparatus
Beta2-microglobulin
Loops of Henle
Renin-angiotensin-aldosterone
system (RAAS)
Collecting duct
Maximal reabsorptive capacity (Tm)
Shield of negativity
Countercurrent mechanism
Nephron
Titratable acidity
Creatinine
Osmolality
Tubular reabsorption
Cystatin C
Passive transport
Tubular secretion
Distal convoluted tubule
Peritubular capillaries
Vasa recta
Efferent arteriole
Podocytes
Free water clearance
Proximal convoluted tubule
3920_Ch03_039-057 23/01/14 10:10 AM Page 40
40
Part One | Background
This chapter reviews nephron anatomy and physiology and
discusses their relationship to urinalysis and renal function
testing. A section on laboratory assessment of renal function is
included.
Renal Physiology
Each kidney contains approximately 1 to 1.5 million functional
units called nephrons. As shown in Figure 3–1, the human
kidney contains two types of nephrons. Cortical nephrons,
which make up approximately 85% of nephrons, are situated
primarily in the cortex of the kidney. They are responsible primarily for removal of waste products and reabsorption of
nutrients. Juxtamedullary nephrons have longer loops of Henle
that extend deep into the medulla of the kidney. Their primary
function is concentration of the urine.
The ability of the kidneys to clear waste products selectively from the blood and simultaneously to maintain the body’s
essential water and electrolyte balances is controlled in the
nephron by the following renal functions: renal blood flow,
glomerular filtration, tubular reabsorption, and tubular
secretion. The physiology, laboratory testing, and associated
pathology of these four functions are discussed in this chapter.
Renal Blood Flow
The renal artery supplies blood to the kidney. The human kidneys receive approximately 25% of the blood pumped through
the heart at all times. Blood enters the capillaries of the
Glomerulus
Renal
cortex
Cortical
nephron
Renal
tubule
Papilla of
pyramid
Renal
artery
Renal
medulla
Loop of
Henle
Juxtamedullary
nephron
Collecting
duct
Calyx
Renal
vein
Cortex
Renal pelvis
Ureter
Urinary bladder
Urethra
Figure 3–1 The relationship of the nephron to
the kidney and excretory system. (From Scanlon,
VC, and Sanders, T: Essentials of Anatomy and
Physiology, ed 3. FA Davis, Philadelphia, PA,
1999, p 405, with permission.)
3920_Ch03_039-057 23/01/14 10:10 AM Page 41
Chapter 3 | Renal Function
nephron through the afferent arteriole. It then flows through
the glomerulus and into the efferent arteriole. The varying
sizes of these arterioles help to create the hydrostatic pressure
differential important for glomerular filtration and to maintain
consistency of glomerular capillary pressure and renal blood
flow within the glomerulus. Notice the smaller size of the
efferent arteriole in Figure 3–2. This increases the glomerular
capillary pressure.
Before returning to the renal vein, blood from the efferent
arteriole enters the peritubular capillaries and the vasa recta
and flows slowly through the cortex and medulla of the kidney
close to the tubules. The peritubular capillaries surround the
proximal and distal convoluted tubules, providing for the immediate reabsorption of essential substances from the fluid in
the proximal convoluted tubule and final adjustment of the
urinary composition in the distal convoluted tubule. The vasa
recta are located adjacent to the ascending and descending
loops of Henle in juxtamedullary nephrons. In this area,
the major exchanges of water and salts take place between the
blood and the medullary interstitium. This exchange maintains
the osmotic gradient (salt concentration) in the medulla,
which is necessary for renal concentration.
Based on an average body size of 1.73 m2 of surface, the
total renal blood flow is approximately 1200 mL/min, and the
total renal plasma flow ranges from 600 to 700 mL/min. Normal values for renal blood flow and renal function tests depend
on body size. When dealing with sizes that vary greatly
from the average 1.73 m2 of body surface, a correction must
41
be calculated to determine whether the observed measurements represent normal function. This calculation is covered
in the discussion on tests for glomerular filtration rate (GFR)
later in this chapter. Variations in normal values have been
published for different age groups and should be considered
when evaluating renal function studies.
Glomerular Filtration
The glomerulus consists of a coil of approximately eight capillary lobes, the walls of which are referred to as the glomerular
filtration barrier. It is located within Bowman’s capsule,
which forms the beginning of the renal tubule. Although the
glomerulus serves as a nonselective filter of plasma substances
with molecular weights less than 70,000, several factors influence the actual filtration process. These include the cellular
structure of the capillary walls and Bowman’s capsule, hydrostatic pressure and oncotic pressure, and the feedback mechanisms of the renin-angiotensin-aldosterone system (RAAS).
Cellular Structure of the Glomerulus
Plasma filtrate must pass through three glomerular filtration
barrier cellular layers: the capillary wall membrane, the basement membrane (basal lamina), and the visceral epithelium of
Bowman’s capsule. The endothelial cells of the capillary wall
differ from those in other capillaries by containing pores and
are referred to as fenestrated. The pores increase capillary permeability but do not allow the passage of large molecules and
Afferent
arteriole
Juxtaglomerular
apparatus
Efferent
arteriole
Bowman’s
capsule
Glomerulus
Distal
convoluted
tubule
Proximal
convoluted
tubule
Peritubular
capillaries
Thick descending
loop of Henle
Vasa recta
Thin descending
loop of Henle
Figure 3–2 The nephron and its component
parts.
Cortex
Collecting
duct
Vasa recta
Medulla
Thick ascending
loop of Henle
Thin ascending
loop of Henle
3920_Ch03_039-057 23/01/14 10:10 AM Page 42
42
Part One | Background
blood cells. Further restriction of large molecules occurs as the
filtrate passes through the basement membrane and the thin
membranes covering the filtration slits formed by the intertwining foot processes of the podocytes of the inner layer of
Bowman’s capsule (see Fig. 3–3A).
In addition to the structure of the glomerular filtration barrier that prohibits the filtration of large molecules, the barrier
contains a shield of negativity that repels molecules with a
positive charge even though they are small enough to pass
through the three layers of the barrier. The shield is very important because albumin (the primary protein associated with
renal disease) has a positive charge and would easily pass
through the barrier (see Fig. 3–3B).
Glomerular Pressure
As mentioned previously, the presence of hydrostatic pressure
resulting from the smaller size of the efferent arteriole and the
glomerular capillaries enhances filtration. This pressure is necessary to overcome the opposition of pressures from the fluid
within Bowman’s capsule and the oncotic pressure of unfiltered
plasma proteins in the glomerular capillaries. By increasing or
decreasing the size of the afferent and efferent arterioles, an autoregulatory mechanism within the juxtaglomerular apparatus maintains the glomerular blood pressure at a relatively
constant rate regardless of fluctuations in systemic blood pressure. Dilation of the afferent arterioles and constriction of the
TECHNICAL TIP If it were not for the shield of negativity,
all routine urines would have positive reagent strip readings for protein/albumin.
efferent arterioles when blood pressure drops prevents a
marked decrease in blood flowing through the kidney, thus
preventing an increase in the blood level of toxic waste products. Likewise, an increase in blood pressure results in constriction of the afferent arterioles to prevent overfiltration or
damage to the glomerulus.
Renin-Angiotensin-Aldosterone System
The renin-angiotensin-aldosterone system regulates the flow
of blood to and within the glomerulus. The system responds
to changes in blood pressure and plasma sodium content that
are monitored by the juxtaglomerular apparatus, which consists of the juxtaglomerular cells in the afferent arteriole and
the macula densa of the distal convoluted tubule (Fig. 3–4).
Low plasma sodium content decreases water retention within
the circulatory system, resulting in a decreased overall blood
volume and subsequent decrease in blood pressure. When the
macula densa senses such changes, a cascade of reactions
within the RAAS occurs (Fig. 3–5). Renin, an enzyme produced by the juxtaglomerular cells, is secreted and reacts with
the blood-borne substrate angiotensinogen to produce the inert
hormone angiotensin I. As angiotensin I passes through the
alveoli of the lungs, angiotensin-converting enzyme (ACE)
changes it to the active form angiotensin II. Angiotensin II corrects renal blood flow in the following ways: causing vasodilation of the afferent arterioles and constriction of the efferent
arterioles, stimulating reabsorption of sodium and water in the
proximal convoluted tubules, and triggering the release of the
sodium-retaining hormone aldosterone by the adrenal cortex
and antidiuretic hormone by the hypothalamus (Table 3–1).
As systemic blood pressure and plasma sodium content increase, the secretion of renin decreases. Therefore, the actions
Afferent
arteriole
Efferent
arteriole
Glomerular
basement
membrane
Hydrostatic
pressure
Oncotic
pressure
(unfiltered
plasma
proteins)
Protein
Glomerular
basement
membrane
Foot
processes
of podocyte
B
Fenestrated
epithelium
Slit diaphragm
Podocyte foot
process
Podocyte
Bowman’s
space
Proximal convoluted
tubule
Blood
A
C
Glomerular
basement
membrane
Fenestrated
endothelium
Figure 3–3 Factors affecting glomerular filtration in the renal corpuscle (A). Inset B, glomerular filtration barrier. Inset C, the shield of
negativity.
3920_Ch03_039-057 23/01/14 10:10 AM Page 43
Chapter 3 | Renal Function
Afferent
arteriole
Distal tubule
Macula
densa
Table 3–1
Efferent
arteriole
Juxtaglomerular
cells
Glomerulus
Figure 3–4 Close contact of the distal tubule with the afferent arteriole, macula densa, and the juxtaglomerular cells within the juxtaglomerular apparatus. Note the smaller size of the afferent arteriole
indicating increased blood pressure.
of angiotensin II produce a constant pressure within the
nephron.
As a result of the above glomerular mechanisms, every
minute approximately two to three million glomeruli filter approximately 120 mL of water-containing low-molecular-weight
substances. Because this filtration is nonselective, the only difference between the compositions of the filtrate and the plasma
43
Actions of the RAAS
1. Dilates the afferent arteriole and constricts the efferent
arteriole
2. Stimulates sodium reabsorption in the proximal convoluted tubule
3. Triggers the adrenal cortex to release the sodiumretaining hormone aldosterone to cause sodium reabsorption and potassium excretion in the distal convoluted tubule and collecting duct
4. Triggers antidiuretic hormone release by the hypothalamus to stimulate water reabsorption in the
collecting duct
is the absence of plasma protein, any protein-bound substances, and cells. Analysis of the fluid as it leaves the glomerulus shows the filtrate to have a specific gravity of 1.010 and
confirms that it is chemically an ultrafiltrate of plasma. This
information provides a useful baseline for evaluating the renal
mechanisms involved in converting the plasma ultrafiltrate into
the final urinary product.
Tubular Reabsorption
The body cannot lose 120 mL of water-containing essential
substances every minute. Therefore, when the plasma ultrafiltrate enters the proximal convoluted tubule, the nephrons,
through cellular transport mechanisms, begin reabsorbing
these essential substances and water (Table 3–2).
Reabsorption Mechanisms
The cellular mechanisms involved in tubular reabsorption are
termed active transport and passive transport. For active
transport to occur, the substance to be reabsorbed must combine with a carrier protein contained in the membranes of the
Low blood pressure
Low plasma sodium
Renin secretion
Angiotensinogen
Angiotensin I
Angiotensin
converting enzymes
Angiotensin II
Vasoconstriction
Figure 3–5 Algorithm of the reninangiotensin-aldosterone system.
Proximal convoluted tubule
Sodium reabsorption
Aldosterone
ADH
Distal convoluted tubule
Sodium reabsorption
Collecting duct
Water resorption
3920_Ch03_039-057 23/01/14 10:10 AM Page 44
44
Part One | Background
Table 3–2
Active
transport
Passive
transport
Tubular Reabsorption
Substance
Location
Glucose,
amino
acids, salts
Chloride
Sodium
Proximal convoluted tubule
Water
Urea
Sodium
Ascending loop of Henle
Proximal and distal convoluted tubules
Proximal convoluted tubule
Descending loop of Henle
Collecting duct
Proximal convoluted tubule
Ascending loop of Henle
Ascending loop of Henle
renal tubular epithelial cells. The electrochemical energy created by this interaction transfers the substance across the cell
membranes and back into the bloodstream. Active transport
is responsible for the reabsorption of glucose, amino acids,
and salts in the proximal convoluted tubule, chloride in the
ascending loop of Henle, and sodium in the distal convoluted
tubule.
Passive transport is the movement of molecules across a
membrane as a result of differences in their concentration or
electrical potential on opposite sides of the membrane. These
physical differences are called gradients. Passive reabsorption
of water takes place in all parts of the nephron except the ascending loop of Henle, the walls of which are impermeable to
water. Urea is passively reabsorbed in the proximal convoluted
tubule and the ascending loop of Henle, and passive reabsorption of sodium accompanies the active transport of chloride in
the ascending loop.
Active transport, like passive transport, can be influenced
by the concentration of the substance being transported.
When the plasma concentration of a substance that is normally completely reabsorbed reaches an abnormally high
level, the filtrate concentration exceeds the maximal reabsorptive capacity (Tm) of the tubules, and the substance
begins appearing in the urine. The plasma concentration at
which active transport stops is termed the renal threshold.
For glucose, the plasma renal threshold is 160 to 180 mg/dL,
and glucose appears in the urine when the plasma concentration reaches this level. Knowledge of the renal threshold
and the plasma concentration can be used to distinguish between excess solute filtration and renal tubular damage.
Active transport of more than two-thirds of the filtered
sodium out of the proximal convoluted tubule is accompanied by the passive reabsorption of an equal amount of water.
Therefore, as can be seen in Figure 3–6, the fluid leaving the
proximal convoluted tubule still maintains the same concentration as the ultrafiltrate.
TECHNICAL TIP Glucose appearing in the urine of a
person with a normal blood glucose level is the result of
tubular damage and not diabetes mellitus. A nonfasting
patient with high glucose intake would not have a normal
blood glucose.
Tubular Concentration
Renal concentration begins in the descending and ascending
loops of Henle, where the filtrate is exposed to the high
osmotic gradient of the renal medulla. Water is removed by
osmosis in the descending loop of Henle, and sodium and
chloride are reabsorbed in the ascending loop. Excessive reabsorption of water as the filtrate passes through the highly concentrated medulla is prevented by the water-impermeable walls
of the ascending loop. This selective reabsorption process is
called the countercurrent mechanism and serves to maintain
the osmotic gradient of the medulla (see Fig. 3–6). The sodium
and chloride leaving the filtrate in the ascending loop prevent
dilution of the medullary interstitium by the water reabsorbed
from the descending loop. Maintenance of this osmotic gradient is essential for the final concentration of the filtrate when
it reaches the collecting duct.
In Figure 3–6, the actual concentration of the filtrate leaving the ascending loop is quite low owing to the reabsorption
of salt and not water in that part of the tubule. Reabsorption
of sodium continues in the distal convoluted tubule, but it is
now under the control of the hormone aldosterone, which regulates reabsorption in response to the body’s need for sodium
(see Fig. 3–5).
Collecting Duct Concentration
The final concentration of the filtrate through the reabsorption
of water begins in the late distal convoluted tubule and continues in the collecting duct. Reabsorption depends on the osmotic gradient in the medulla and the hormone vasopressin
(antidiuretic hormone [ADH]). One would expect that as the
dilute filtrate in the collecting duct comes in contact with the
higher osmotic concentration of the medullary interstitium,
passive reabsorption of water would occur. However, the
process is controlled by the presence or absence of ADH, which
renders the walls of the distal convoluted tubule and collecting
duct permeable or impermeable to water. A high level of ADH
increases permeability, resulting in increased reabsorption of
water, and a low-volume concentrated urine. Likewise, absence
of ADH renders the walls impermeable to water, resulting in a
large volume of dilute urine. Just as the production of aldosterone is controlled by the body’s sodium concentration, production of ADH is determined by the state of body hydration.
Therefore, the chemical balance in the body is actually the final
determinant of urine volume and concentration. The concept
of ADH control can be summarized in the following manner:
↑Body Hydration = ↓ADH = ↑Urine Volume
↓Body Hydration = ↑ADH = ↓Urine Volume
3920_Ch03_039-057 23/01/14 10:10 AM Page 45
Chapter 3 | Renal Function
Cortex
45
Blood (vein)
300 mOsm/L
Efferent
arteriole
Proximal convoluted tubule
300
Glomerulus
Na+Cl- H2O
300
H2O
100
Descending
limb
H2O
600
Na+ClThick
ascending
limb
Na+
Na+Cl-
H2O
H2O
Na+
H2O
900
H2O
H2O
Loop of
Henle
1200
Medulla
Countercurrent mechanism
Reabsorption
Secretion
Variable
reabsorption
Figure 3–6 Renal concentration.
Tubular Secretion
In contrast to tubular reabsorption, in which substances are
removed from the glomerular filtrate and returned to the
blood, tubular secretion involves the passage of substances
from the blood in the peritubular capillaries to the tubular filtrate (Fig. 3–7). Tubular secretion serves two major functions:
eliminating waste products not filtered by the glomerulus and
regulating the acid–base balance in the body through the secretion of hydrogen ions.
Many foreign substances, such as medications, cannot be
filtered by the glomerulus because they are bound to plasma
proteins. When these protein-bound substances enter the peritubular capillaries, they develop a stronger affinity for the tubular cells and dissociate from their carrier proteins, which
results in their transport into the filtrate by the tubular cells.
The major site for removal of these nonfiltered substances is
the proximal convoluted tubule.
Efferent
arteriole
Afferent
arteriole
Bowman’s
capsule
Glomerular
filtrate
Reabsorption
To blood
Secretion
Tubule
To urine
Figure 3–7 Summary of movement of substances in the
nephron.
3920_Ch03_039-057 23/01/14 10:10 AM Page 46
46
Part One | Background
Acid–Base Balance
Tubular
lumen
To maintain the normal blood pH of 7.4, the blood must buffer
and eliminate the excess acid formed by dietary intake and
body metabolism. The buffering capacity of the blood depends
on bicarbonate (HCO3–) ions, which are readily filtered by the
glomerulus and must be expediently returned to the blood to
maintain the proper pH. As shown in Figure 3–8, the secretion
of hydrogen ions (H+) by the renal tubular cells into the filtrate
prevents the filtered bicarbonate from being excreted in the
urine and causes the return of a bicarbonate ion to the plasma.
This process provides for almost 100% reabsorption of filtered
bicarbonate and occurs primarily in the proximal convoluted
tubule.
As a result of their small molecular size, hydrogen ions are
readily filtered and reabsorbed. Therefore, the actual excretion
of excess hydrogen ions also depends on tubular secretion.
Figures 3–9 and 3–10 are diagrams of the two primary methods for hydrogen ion excretion in the urine. In Figure 3–9 the
secreted hydrogen ion combines with a filtered phosphate ion
instead of a bicarbonate ion and is excreted rather than reabsorbed. In the proximal convoluted tubule, ammonia is
produced from the breakdown of the amino acid glutamine.
The ammonia reacts with the H+ to form the ammonium ion
Tubular
lumen
Renal tubular
cell
Peritubular
plasma
HCO3– (filtered)
HCO3 + H+
H+
HCO3
–
HCO3
–
H2CO3
H2CO3
Carbonic anhydrase
H2O + CO2
H2O + CO2
Renal tubular
cell
Peritubular
plasma
NH3
NH3 + H+
H+
HCO3
–
HCO3
–
H2CO3
NH4+
Carbonic anhydrase
H2O + CO2
CO2
Final urine
Figure 3–10 Excretion of secreted hydrogen ions combined with
ammonia produced by the tubules.
(NH4+) (see Fig. 3–10). The resulting ammonium ion is excreted in the urine. Should there be additional need for elimination of hydrogen ions, the distal convoluted tubule and the
collecting duct are also able to produce ammonium ion.
All three of these processes occur simultaneously at rates
determined by the acid–base balance in the body. A disruption
in these secretory functions can result in metabolic acidosis or
renal tubular acidosis, the inability to produce an acid urine.
Renal Function Tests
This brief review of renal physiology shows that there are many
metabolic functions and chemical interactions to be evaluated
through laboratory tests of renal function. In Figure 3–11, the
parts of the nephron are related to the laboratory tests used to
assess their function.
PAH
CO2
Osmolarity
GFR
tests
Final urine
Figure 3–8 Reabsorption of filtered bicarbonate.
Tubular
lumen
Renal tubular
cell
Ammonia
Peritubular
plasma
HPO4– (filtered)
HPO4– + H+
H+
HCO3–
HCO3–
H2CO3
H2PO4
Titratable
acidity
Free water
clearance
Carbonic anhydrase
Osmolarity
H2O + CO2
CO2
Final urine
Figure 3–9 Excretion of secreted hydrogen ions combined with
phosphate.
Figure 3–11 The relationship of nephron areas to renal function
tests.
3920_Ch03_039-057 23/01/14 10:10 AM Page 47
Chapter 3 | Renal Function
Glomerular Filtration Tests
The standard tests used to measure the filtering capacity of
the glomeruli are termed clearance tests. As its name implies,
a clearance test measures the rate at which the kidneys are able
to remove (to clear) a filterable substance from the blood. To
ensure that glomerular filtration is being measured accurately,
the substance analyzed must be one that is neither reabsorbed
nor secreted by the tubules. Other factors to consider in selecting a clearance test substance include the stability of the
substance in urine during a possible 24-hour collection period,
the plasma level consistency, the substance’s availability to the
body, and the availability of tests to analyze the substance.
Clearance Tests
A variety of substances have been used to measure the GFR.
Newer methods that eliminate many of the problems mentioned above have replaced some of these tests. They are summarized as Historical Notes.
At present, creatinine, beta2-microglobulin, cystatin C, and
possibly radioisotopes are the primary substances used in clearance tests. Each procedure has its advantages and disadvantages.
A test that requires an infused substance is termed an exogenous procedure and is seldom the method of choice if a
suitable test substance is already present in the body (endogenous procedure).
HISTORICAL NOTE
Urea Clearance
The earliest glomerular filtration tests measured urea
because of its presence in all urine specimens and the
existence of routinely used methods of chemical analysis.
Because approximately 40% of the filtered urea is reabsorbed, normal values were adjusted to reflect the reabsorption, and patients were hydrated to produce a urine flow
of 2 mL/min to ensure that no more than 40% of the urea
was reabsorbed.
HISTORICAL NOTE
Inulin Clearance
Inulin, a polymer of fructose, is an extremely stable substance that is not reabsorbed or secreted by the tubules. It
is not a normal body constituent, however, and must be
infused by IV at a constant rate throughout the testing
period. Therefore, although inulin was the original reference method for clearance tests, current methods are available that are endogenous and can provide accurate GFR
results.
47
Creatinine Clearance
Creatinine is a waste product of muscle metabolism that is produced enzymatically by creatine phosphokinase from creatine,
which links with ATP to produce ADP and energy. Because creatinine is normally found at a relatively constant level in the
blood, it provides the laboratory with an endogenous procedure for evaluating glomerular function. The use of creatinine
has several disadvantages and careful consideration should be
given to them. They are as follows:
1. Some creatinine is secreted by the tubules, and secretion
increases as blood levels rise.
2. Chromogens present in human plasma react in the
chemical analysis. Their presence, however, may help
counteract the falsely elevated rates caused by tubular
secretion.
3. Medications, including gentamicin, cephalosporins, and
cimetidine (Tagamet), inhibit tubular secretion of creatinine, thus causing falsely low serum levels.1
4. Bacteria will break down urinary creatinine if specimens
are kept at room temperature for extended periods.2
5. A diet heavy in meat consumed during collection of a
24-hour urine specimen will influence the results if the
plasma specimen is drawn before the collection period
because the increased intake of meat can raise the urine
and plasma levels of creatinine during the 24-hour collection period.
6. Measurement of creatinine clearance is not a reliable
indicator in patients suffering from muscle-wasting diseases or persons involved in heavy exercise or athletes
supplementing with creatine.
7. Accurate results depend on the accurate completeness
of a 24-hour collection.
8. It must be corrected for body surface area, unless
normal is assumed, and must always be corrected for
children.
Newer methods that do not require the collection of timed
(24-hour) urine specimens have been developed using just the
serum creatinine, cystatin C, or beta2-microglobulin values.
The results of these tests are reported as estimated glomerular
filtration rate (eGFR). The traditional creatinine clearance procedure is included here because it is still being performed and
its principles apply to other clearance procedures using urine.
Procedure
By far the greatest source of error in any clearance procedure
using urine is the use of improperly timed urine specimens.
The importance of using an accurately timed specimen (see
Chapter 2) will become evident in the following discussion of
the calculations involved in converting isolated laboratory
measurements to the GFR. The GFR is reported in milliliters
cleared per minute; therefore, determining the number of milliliters of plasma from which the clearance substance (creatinine) is completely removed during 1 minute is necessary. To
calculate this information, one must know urine volume in
3920_Ch03_039-057 23/01/14 10:10 AM Page 48
48
Part One | Background
mL/min (V), urine creatinine concentration in mg/dL (U), and
plasma creatinine concentration in mg/dL (P).
The urine volume is calculated by dividing the number of
milliliters in the specimen by the number of minutes used to
collect the specimen.
EXAMPLE
Calculate the urine volume (V) for a 2-hour specimen measuring 240 mL:
2 hours × 60 minutes = 120 minutes
240 mL/120 minutes = 2 mL/min
V = 2 mL/min
The plasma and urine concentrations are determined by
chemical testing. The standard formula used to calculate
the milliliters of plasma cleared per minute (C) is:
C=
UV
1.73
×
P
A
with A being the actual body size in square meters of surface.
The actual body size may be calculated as:
log A = (0.425 × log weight) + (0.725 × log height)
– 2.144
or it may be obtained from the nomogram shown in Figure 3–13.
Estimated Glomerular Filtration Rates
1440 mL
= 1 mL/min
60 minutes × 24 = 1440 minutes
In the past years a variety of formulas for estimating glomerular
filtration rates (eGFR) have been used and they continue to be
revised. Because the formulas can be programmed into automated instruments, estimated clearances can be used for routinely screening patients as part of a metabolic profile and also
to monitor patients already diagnosed with renal disease or at
risk for renal disease. In addition, the formulas are valuable
when medications that require adequate renal clearance need
to be prescribed.
The most frequently used formula is called the Modification of Diet in Renal Disease (MDRD) study. The formula has
been modified several times to make it more accurate and standardized. At the present time the formula recommended by the
National Kidney Disease Education Program (NKDEP) is called
the MDRD-IDMS-traceable formula. A primary discrepancy in
the previous formulas was found to be the methods used to
measure serum creatinine. Current laboratory methods primarily
use creatinine assays such as enzyme assays that do not have
the same interference as the original Jaffe chemical method.
These methods correspond more closely to the isotope dilution
mass spectrophotometry (IDMS) reference method.
The MDRD-IDMS traceable formula is:
120 mg/dL × 1 mL/min (V)
= 120 mL/dL
1.0 mg/dL (P)
GFR = 175 × serum creatinine –1154 × age –0.203 × 0.742
(if patient is female) × 1.202 (if patient is black)
C =
UV
P
This formula is derived as follows. The milliliters of plasma
cleared per minute (C) times the mg/dL of plasma creatinine
(P) must equal the mg/dL of urine creatinine (U) times the
urine volume in mL/min (V), because all of the filtered creatinine will appear in the urine. Therefore:
CP = UV and C =
UV
P
EXAMPLE
Using urine creatinine of 120 mg/dL (U), plasma creatinine of
1.0 mg/dL (P), and urine volume of 1440 mL obtained from a
24-hour specimen (V), calculate the GFR.
V =
the calculation when dealing with body sizes that deviate
greatly from 1.73 m2 of surface, such as with children. To
adjust a clearance for body size, the formula is:
C =
By analyzing this calculation and referring to Figure 3–12, at
a 1 mg/dL concentration, each milliliter of plasma contains
0.01 mg creatinine. Therefore, to arrive at a urine concentration of 120 mg/dL (1.2 mg/mL), it is necessary to clear 120 mL
of plasma. Although the filtrate volume is reduced, the
amount of creatinine in the filtrate does not change because
the creatinine is not reabsorbed.
Knowing that in the average person (1.73 m2 body surface) the approximate amount of plasma filtrate produced
per minute is 120 mL, it is not surprising that normal creatinine clearance values approach 120 mL/min (men, 107 to
139 mL/min; women, 87 to 107 mL/min). The normal reference range of plasma creatinine is 0.5 to 1.5 mg/dL. These
reference values take into account variations in size and
muscle mass. Values are considerably lower in older people,
however, and an adjustment may also have to be made to
Plasma (1 mg/dL = 0.01 mg/mL creatinine)
Glomerulus
Plasma filtrate (120 mL/min x 0.01 mg/mL = 1.2 mg)
Reabsorption
(119 mL H2O)
Urine (1 mL/min)
Creatinine (1.2 mg/mL or 120 mg/dL)
Figure 3–12 Creatinine filtration and excretion.
3920_Ch03_039-057 23/01/14 10:10 AM Page 49
Chapter 3 | Renal Function
5'
10"
8"
Height in feet
6"
4"
2"
4'
10"
8"
6"
4"
2"
150
145
140
135
130
125
120
115
110
105
1.05
180
170
180
160
150
140
120
110
140
.95
95
90
80
75
70
65
60
120
55
110
50
100
45
40
.90
95
.80
.75
80
35
70
30
.70
85
60
.65
8"
80
75
.60
Formula for MDRD calculation of GFR when the serum
creatinine method is not standardized to IDMS.
GFR = 173 × serum creatinine–1.154 × age–0.203 × 0.742
(if patient is female) × 1.212 (if patient is black)
Cystatin C
85
130
90
Original MDRD Calculation
100
160
150
HISTORICAL NOTE
130
1.00
.85
90
6"
1.10
100
3'
10"
1.15
190
190
Weight in kilograms
2"
160
155
170
300
290
280
270
260
250
240
230
220
210
200
Weight in pounds
6"
4"
380
360
320
2.10
2.00
1.95
1.90
1.85
1.80
1.75
1.70
1.65
1.60
1.55
1.50
1.45
1.40
1.35
1.30
1.25
1.20
200
340
2.30
2.20
Surface area in square meters
6'
10"
8"
220
215
210
205
200
195
190
185
180
175
170
165
Height in centimeters
7'
10"
8"
6"
4"
2"
3.00
2.90
2.80
2.70
2.60
2.50
2.40
440
420
400
49
25
50
.55
20
.50
40
15
Figure 3–13 A nomogram for determining body surface area.
(From Boothby, WM, and Sandiford, RB: Nomogram for determination of body surface area. N Engl J Med 185:227, 1921, with
permission.)
The formula is designed to essentially equal the results
that compare to the reference body size of 1.73 m2.
Because eGFRs are calculated for an average body size they
are not accurate for pediatric patients. They have also been
shown to be most accurate when results are lower than
60 mL/min.3 It is recommended that results be reported with
numerical values below 60 mL/min and higher values reported
as equal to or greater than 60 mL/min.
The formula recommended for use when serum creatinine
methods do not compare to the IDSM standard is provided as
a Historical Note.
Measurement of serum cystatin C has been shown to provide
a good procedure for screening and monitoring GFR. Cystatin
C is a small protein (molecular weight 13,359) produced at a
constant rate by all nucleated cells. It is readily filtered by the
glomerulus and reabsorbed and broken down by the renal tubular cells. Therefore, no cystatin C is secreted by the tubules,
and the serum concentration can be directly related to the GFR.
Immunoassay procedures are available for measuring cystatin
C.4 Monitoring levels of cystatin C is recommended for pediatric patients, persons with diabetes, the elderly, and critically
ill patients.5 An advantage of cystatin C is that it is independent
of muscle mass.
Recent studies also have shown that measuring both
serum or plasma cystatin C and creatinine can provide even
more accurate information on a patient’s GFR.6
Beta2-Microglobulin
Beta2-microglobulin (molecular weight 11,800) dissociates
from human leukocyte antigens at a constant rate and is rapidly
removed from the plasma by glomerular filtration. Sensitive
methods using enzyme immunoassay are available for the
measurement of beta2-microglobulin. A rise in the plasma level
of beta2-microglobulin has been shown to be a more sensitive
indicator of a decrease in GFR than creatinine clearance. However, the test is not reliable in patients who have a history of
immunologic disorders or malignancy.7
Radionucleotides
Although they are exogenous procedures and more labor
intensive and costly, injecting radionucleotides such as 125Iiothalamate provides a method for determining glomerular filtration through the plasma disappearance of the radioactive
material and enables visualization of the filtration in one or
both kidneys.8 This procedure can be valuable to measure the
viability of a transplanted kidney.
Clinical Significance
When interpreting the results of a creatinine clearance test, the
GFR is determined not only by the number of functioning
nephrons but also by the functional capacity of these nephrons.
In other words, even though half of the available nephrons
may be nonfunctional, a change in the GFR will not occur if
the remaining nephrons double their filtering capacity. This is
3920_Ch03_039-057 23/01/14 10:10 AM Page 50
50
Part One | Background
evidenced by persons who lead normal lives with only one kidney. Therefore, although the GFR is a frequently requested laboratory procedure, its value does not lie in the detection of
early renal disease. Instead, it is used to determine the extent
of nephron damage in known cases of renal disease, to monitor
the effectiveness of treatment designed to prevent further
nephron damage, and to determine the feasibility of administering medications, which can build up to dangerous blood
levels if the GFR is markedly reduced.
the volume and specific gravity of day and night urine samples
to evaluate concentrating ability. Neither test is used now because the information provided by specific gravity measurements is most useful as a screening procedure, and quantitative
measurement of renal concentrating ability is best assessed
through osmometry.
Currently renal concentrating testing is performed after
various periods of fluid deprivation, measuring urine and often
serum osmolality. Controlled intake procedures can include
after dinner overnight deprivation of fluid for 12 hours followed by collection of a urine sample. A urine osmolality reading of 800 mOsm or higher is normal and the test can be
discontinued. If the urine test is abnormal, the fluid is restricted for another two hours and both urine and serum
species are collected for osmolality testing. A urine to serum
ratio (U:S ratio) of 3:1 or greater or a urine osmolality of
800 mOsm or greater indicates normal tubular reabsorption.
If the test continues to be abnormal, additional testing is
performed to determine whether the failure to concentrate the
urine is caused by diabetes insipidus that occurs as the result
of a problem with the production or the response of the kidney
to ADH. The patient is injected with ADH and serum and urine
specimens are collected in 2 and 4 hours. If at this time the
test is normal, it indicates that the patient is not capable of producing ADH (neurogenic diabetes insipidus) and if the test is
abnormal then the renal tubules are not responding to ADH
(nephrogenic diabetes insipidus). See Figure 3–15.
Tubular Reabsorption Tests
Whereas measurement of the GFR is not a useful indication of
early renal disease, the loss of tubular reabsorption capability
is often the first function affected in renal disease. This is not
surprising when one considers the complexity of the tubular
reabsorption process.
Tests to determine the ability of the tubules to reabsorb
the essential salts and water that have been nonselectively filtered by the glomerulus are called concentration tests. As mentioned, the ultrafiltrate that enters the tubules has a specific
gravity of 1.010; therefore, after reabsorption one would expect
the final urine product to be more concentrated. However, as
you perform routine urinalysis, you will see that many specimens do not have a specific gravity higher than 1.010, yet no
renal disease is present. This is because urine concentration is
largely determined by the body’s state of hydration, and the
normal kidney will reabsorb only the amount of water necessary to preserve an adequate supply of body water.
As can be seen in Figure 3–14, both specimens contain
the same amount of solute; however, the urine density (specific
gravity) of patient A will be higher. Therefore, control of fluid
intake must be incorporated into laboratory tests that measure
the concentrating ability of the kidney.
Throughout the years, various methods have been used to
produce water deprivation, including the Fishberg and Mosenthal
concentration tests, which measured specific gravity. In the
Fishberg test, patients were deprived of fluids for 24 hours before measuring specific gravity. The Mosenthal test compared
Patient A
Patient B
Water (1 glass)
Water (4 glasses)
Glomerulus
Glomerulus
Ultrafiltrate
120 mL Water
300 mg Solute
Reabsorption
Urine
1 mL Water
200 mg Solute
Specific gravity 1.015
Ultrafiltrate
119 mL Water
100 mg Solute
Osmolality
As will be discussed in Chapter 4, osmolality measures only
the number of particles in a solution, whereas specific gravity
is influenced by the number and density (molecular weight)
of the particles. Renal concentration is concerned with small
particles, primarily sodium and chloride molecules. Largemolecular-weight molecules such as glucose and urea do not
contribute to the evaluation of renal concentration. Therefore
osmolality is performed for a more accurate evaluation of renal
concentrating ability.
120 mL Water
300 mg Solute
Reabsorption
Urine
10 mL Water
200 mg Solute
Specific gravity 1.005
110 mL Water
100 mg Solute
Figure 3–14 The effect of hydration
on renal concentration. Notice the decreased specific gravity in the morehydrated Patient B.
3920_Ch03_039-057 23/01/14 10:10 AM Page 51
Chapter 3 | Renal Function
Polyuria
Urine osmolality <200 mOsm, Urine:Serum 1:1
Fluid Restriction
Urine osmolality <400 mOsm, Urine:Serum 1:1
ADH Challenge
Urine osmolality >800 mOsm,
Urine:Serum 3:1
Urine osmolality <400 mOsm,
Urine:Serum 1:1
Neurogenic diabetes
insipidus
Nephrogenic diabetes
insipidus
Figure 3–15 Differentiation of neurogenic and nephrogenic diabetes
insipidus.
Freezing Point Osmometers
Measurement of freezing point depression was the first principle
incorporated into clinical osmometers, and many instruments
employing this technique are available. These osmometers
determine the freezing point of a solution by supercooling a
measured amount of sample to approximately 27°C. The supercooled sample is vibrated to produce crystallization of water
in the solution. The heat of fusion produced by the crystallizing
water temporarily raises the temperature of the solution to
its freezing point. A temperature-sensitive probe called a
thermistor, in which resistance decreases as temperature increases, measures this temperature increase, which corresponds
to the freezing point of the solution, and the information is
converted into milliosmoles. Conversion is made possible by
the fact that 1 mol (1000 mOsm) of a nonionizing substance
dissolved in 1 kg of water is known to lower the freezing point
1.86°C. Therefore, by comparing the freezing point depression
of an unknown solution with that of a known molal solution,
the osmolarity of the unknown solution can be calculated.
Clinical osmometers use solutions of known NaCl concentration as their reference standards because a solution of partially
ionized substances is more representative of urine and plasma
composition.
Vapor Pressure Osmometers
The other instrument used in clinical osmometry is called the
vapor pressure osmometer. The actual measurement performed, however, is that of the dew point (temperature at
which water vapor condenses to a liquid). The depression of
dew point temperature by solute parallels the decrease in
vapor pressure, thereby providing a measure of this colligative
property.
Samples are absorbed into small filter paper disks that are
placed in a sealed chamber containing a temperature-sensitive
thermocoupler. The sample evaporates in the chamber, forming a vapor. When the temperature in the chamber is lowered,
water condenses in the chamber and on the thermocoupler.
The heat of condensation produced raises the temperature of
51
the thermocoupler to the dew point temperature. This dew
point temperature is proportional to the vapor pressure from
the evaporating sample. Temperatures are compared with those
of the NaCl standards and converted into milliosmoles.
The vapor pressure osmometer uses microsamples of less than
0.01 mL; therefore, care must be taken to prevent any evaporation of the sample prior to testing. Correlation studies have
shown more variation with vapor pressure osmometers, stressing the necessity of careful technique.
Technical Factors
Factors to consider because of their influence on true osmolarity readings include lipemic serum, lactic acid, and volatile
substances, such as ethanol, in the specimen. In lipemic serum,
the serum water displacement by insoluble lipids produces
erroneous results with both vapor pressure and freezing point
osmometers. Falsely elevated values owing to lactic acid formation also occur with both methods if serum samples are not
separated or refrigerated within 20 minutes. Vapor pressure
osmometers do not detect the presence of volatile substances,
such as alcohol, as they become part of the solvent phase; however, measurements performed on similar specimens using
freezing point osmometers will be elevated.
Clinical Significance
Major clinical uses of osmolarity include initially evaluating
renal concentrating ability, monitoring the course of renal disease, monitoring fluid and electrolyte therapy, establishing the
differential diagnosis of hypernatremia and hyponatremia,
and evaluating the secretion of and renal response to ADH.
These evaluations may require determination of serum in addition to urine osmolarity.
Reference serum osmolality values are from 275 to
300 mOsm. Reference values for urine osmolality are difficult
to establish, because factors such as fluid intake and exercise
can greatly influence the urine concentration. Values can range
from 50 to 1400 mOsm.2 Determining the ratio of urine to
serum osmolality can provide a more accurate evaluation.
Under normal random conditions, the ratio of urine to serum
osmolality should be at least 1:1; after controlled fluid intake,
it should reach 3:1 (see Fig. 3–15).
The ratio of urine to serum osmolality, in conjunction with
procedures such as controlled fluid intake and injection of
ADH, is used to differentiate whether diabetes insipidus is
caused by decreased ADH production or inability of the renal
tubules to respond to ADH. Failure to achieve a ratio of 3:1
after injecting ADH indicates that the collecting duct does not
have functional ADH receptors. In contrast, if concentration
takes place after ADH injection, an inability to produce
TECHNICAL TIP Vapor pressure osmometers are used
primarily to analyze serum and sweat microsamples for
disorders not related to renal function, such as cystic fibrosis. They are used primarily in the chemistry department.
3920_Ch03_039-057 23/01/14 10:10 AM Page 52
52
Part One | Background
adequate ADH is indicated. Tests to measure the ADH concentration in plasma and urine directly are available for difficult
diagnostic cases.9
Free Water Clearance
The ratio of urine to serum osmolarity can be further expanded
by performing the analyses using water deprivation and a
timed urine specimen and calculating the free water clearance. The free water clearance is determined by first calculating
the osmolar clearance using the standard clearance formula:
Cosm = Uosm × V
Posm
and then subtracting the osmolar clearance value from the
urine volume in mL/min.
EXAMPLE
Using a urine osmolality of 600 mOsm (U), a urine volume
of 2 mL/min (V), and a plasma osmolality of 300 mOsm (P),
calculate the free water clearance:
Cosm =
600 (U) × 2 (V)
= 4.0 mL/min
300 (P)
CH2O = 2 (V) – 4.0 (Cosm) = –2.0 (free water clearance)
Calculating osmolar clearance indicates how much water
must be cleared each minute to produce a urine with the same
osmolality as the plasma. The ultrafiltrate contains the same
osmolality as the plasma; therefore, the osmotic differences in
the urine are the result of renal concentrating and diluting
mechanisms. By comparing the osmolar clearance with the actual urine volume excreted per minute, it can be determined
whether the water being excreted is more or less than the
amount needed to maintain an osmolality the same as that of
the ultrafiltrate.
The above calculation shows a free water clearance
of –2.0, indicating that less than the necessary amount of water
is being excreted, a possible state of dehydration. If the value
had been 0, no renal concentration or dilution would be taking
place; likewise, if the value had been +2.0, excess water would
have been excreted. The calculation of the free water clearance
is used to determine the ability of the kidney to respond to the
state of body hydration.
Tubular Secretion and Renal Blood
Flow Tests
Tests to measure tubular secretion of nonfiltered substances
and renal blood flow are closely related in that total renal
blood flow through the nephron must be measured by a
substance that is secreted rather than filtered through the
glomerulus. Impaired tubular secretory ability or inadequate
presentation of the substance to the capillaries owing to
decreased renal blood flow may cause an abnormal result.
Therefore, an understanding of the principles and limitations
of the tests and correlation with other clinical data is important in test interpretation.
The test most commonly associated with tubular secretion
and renal blood flow is the p-aminohippuric acid (PAH) test.
PAH Test
To measure the exact amount of blood flowing through the
kidney, it is necessary to use a substance that is completely removed from the blood (plasma) each time it comes in contact
with functional renal tissue. The principle is the same as in the
clearance test for glomerular filtration. However, to ensure
measurement of the blood flow through the entire nephron,
the substance must be removed from the blood primarily in
the peritubular capillaries rather than being removed when the
blood reaches the glomerulus.
Although it has the disadvantage of being exogenous, the
chemical PAH meets the criteria needed to measure renal blood
flow. This nontoxic substance is loosely bound to plasma proteins, which permits its complete removal as the blood passes
through the peritubular capillaries. Except for a small amount
of PAH contained in plasma that does not come in contact with
functional renal tissue, all the plasma PAH is secreted by the
proximal convoluted tubule. Therefore, the volume of plasma
flowing through the kidneys determines the amount of PAH
excreted in the urine. The standard clearance formula can be
used to calculate the effective renal plasma flow:
CPAH (mL/min) =
U (mg/dL PAH) × V (mL/min urine)
P (mg/dL PAH)
Based on normal hematocrit readings, reference values for
the effective renal plasma flow range from 600 to 700 mL/min,
making the average renal blood flow about 1200 mL/min. The
actual measurement is renal plasma flow rather than renal
blood flow, because the PAH is contained only in the plasma
portion of the blood. Also, the term “effective” is included because approximately 8% of the renal blood flow does not come
into contact with the functional renal tissue.
The amount of PAH infused by IV must be monitored
carefully to ensure accurate results; therefore, the test is usually
performed by specialized renal laboratories. Nuclear medicine
procedures using radioactive hippurate can determine renal
blood flow by measuring the plasma disappearance of a single
radioactive injection and at the same time provide visualization
of the blood flowing through the kidneys.9
Titratable Acidity and Urinary Ammonia
The ability of the kidney to produce an acid urine depends on
the tubular secretion of hydrogen ions and production and secretion of ammonia by the cells of the distal convoluted tubule.
A normal person excretes approximately 70 mEq/day of acid
in the form of titratable acid (H+), hydrogen phosphate ions
(H2PO4–), or ammonium ions (NH4+). In normal persons, a
diurnal variation in urine acidity consisting of alkaline tides
appears shortly after arising and postprandially at approximately 2 p.m. and 8 p.m. The lowest pH is found at night.
3920_Ch03_039-057 23/01/14 10:10 AM Page 53
Chapter 3 | Renal Function
HISTORICAL NOTE
the ammonium concentration can be calculated as the difference between the titratable acidity and the total acidity.
Phenolsulfonphthalein Test
Historically, excretion of the dye phenolsulfonphthalein
(PSP) was used to evaluate these functions. Standardization and interpretation of PSP results are difficult, however, because of interference by medications, elevated
waste products in patients’ serum, the necessity to obtain
several very accurately timed urine specimens, and the
possibility of producing anaphylactic shock. Therefore,
the PSP test is not currently performed.
The inability to produce an acid urine in the presence of
metabolic acidosis is called renal tubular acidosis. This condition may result from impaired tubular secretion of hydrogen
ions associated with the proximal convoluted tubule or defects
in ammonia secretion associated with the distal convoluted
tubule.
Urine pH, titratable acidity, and urinary ammonia measurements can be used to determine the defective function. The
tests can be run simultaneously on either fresh or toluenepreserved urine specimens collected at 2-hour intervals from
patients who have been primed with an acid load consisting
of oral ammonium chloride. By titrating the amount of free H+
(titratable acidity) and then the total acidity of the specimen,
53
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Berger, A: Renal function and how to assess it. Brit J Med
321:1444, 2000.
2. Pincus, MR, Preuss, HG, and Henry, JB: Evaluation of renal function and water, electrolyte and acid-base balance. In Henry, JB
(ed): Clinical Diagnosis and Management by Laboratory Methods. WB Saunders, Philadelphia, 1996.
3. Levey, AS, et al: A new equation to estimate glomerular filtration
rate. Ann Intern Med 150(9):601–612, 2009.
4. Laterza, OE, Price, CP, and Scott, MG: Cystatin C: An improved
estimator of glomerular filtration rate? Clin Chem 48(5):
699–707, 2002.
5. Tan, GS, et al: Clinical usefulness of cystatin C for the estimation
of glomerular filtration rate in type 1 diabetes. Crit Care
9(2):139–143, 2005.
6. Inker, LA: Estimating glomerular filtration rate from serum creatinine and cystatin C. N Engl J Med 367:20–29, 2012.
7. Foley, K: Beta 2 microglobulin: a facultative marker. Advance for
MLP, Sept 30, 2008, p 13.
8. Chachati, A, et al: Rapid method for the measurement of differential renal function: Validation. J Nucl Med 28(5): 829–836,
1987.
9. Daves, BB, and Zenser, TV: Evaluation of renal concentrating and
diluting ability. Clin Lab Med 13(1):131–134, 1993.
Study Questions
1. The type of nephron responsible for renal concentration
is the:
A. Cortical
B. Juxtaglomerular
2. The function of the peritubular capillaries is:
A. Reabsorption
B. Filtration
C. Secretion
D. Both A and C
3. Blood flows through the nephron in the following order:
A. Efferent arteriole, peritubular capillaries, vasa recta,
afferent arteriole
B. Peritubular capillaries, afferent arteriole, vasa recta,
efferent arteriole
C. Afferent arteriole, peritubular capillaries, vasa recta,
efferent arteriole
D. Efferent arteriole, vasa recta, peritubular capillaries,
afferent arteriole
4. Filtration of protein is prevented in the glomerulus by:
A. Hydrostatic pressure
B. Oncotic pressure
C. Renin
D. The glomerular filtration barrier
5. The renin-angiotensin-aldosterone system is responsible for
all of the following except:
A. Vasoconstriction of the afferent arteriole
B. Vasoconstriction of the efferent arteriole
C. Reabsorbing sodium
D. Releasing aldosterone
6. The primary chemical affected by the renin-angiotensinaldosterone system is:
A. Chloride
B. Sodium
C. Potassium
D. Hydrogen
3920_Ch03_039-057 23/01/14 10:10 AM Page 54
54
Part One | Background
7. Secretion of renin is stimulated by:
A. Juxtaglomerular cells
14. ADH regulates the final urine concentration by
controlling:
B. Angiotensin I and II
A. Active reabsorption of sodium
C. Macula densa cells
B. Tubular permeability
D. Circulating angiotensin-converting enzyme
8. The hormone aldosterone is responsible for:
A. Hydrogen ion secretion
B. Potassium secretion
C. Chloride retention
D. Sodium retention
9. The fluid leaving the glomerulus has a specific
gravity of:
A. 1.005
B. 1.010
C. 1.015
D. 1.020
10. For active transport to occur, a chemical:
A. Must combine with a carrier protein to create
electrochemical energy
B. Must be filtered through the proximal convoluted
tubule
C. Must be in higher concentration in the filtrate than
in the blood
D. Must be in higher concentration in the blood than in
the filtrate
11. Which of the tubules is impermeable to water?
A. Proximal convoluted tubule
B. Descending loop of Henle
C. Ascending loop of Henle
D. Distal convoluted tubule
12. Glucose will appear in the urine when the:
A. Blood level of glucose is 200 mg/dL
B. Tm for glucose is reached
C. Renal threshold for glucose is exceeded
D. All of the above
13. Concentration of the tubular filtrate by the countercurrent mechanism depends on all of the following
except:
A. High salt concentration in the medulla
B. Water-impermeable walls of the ascending loop of
Henle
C. Passive reabsorption of urea
D. Passive reabsorption of chloride
15. Decreased production of ADH:
A. Produces a low urine volume
B. Produces a high urine volume
C. Increases ammonia excretion
D. Affects active transport of sodium
16. Bicarbonate ions filtered by the glomerulus are returned
to the blood:
A. In the proximal convoluted tubule
B. Combined with hydrogen ions
C. By tubular secretion
D. All of the above
17. If ammonia is not produced by the distal convoluted
tubule, the urine pH will be:
A. Acidic
B. Basic
18. Place the appropriate letter in front of the following clearance substances:
A. Exogenous
B. Endogenous
____ beta2-microglobulin
____ creatinine
____ cystatin C
____ 125I-iothalmate
19. The largest source of error in creatinine clearance tests is:
A. Secretion of creatinine
B. Improperly timed urine specimens
C. Refrigeration of the urine
D. Time of collecting blood sample
20. Given the following information, calculate the creatinine
clearance:
24-hour urine volume: 1000 mL; serum creatinine:
2.0 mg/dL; urine creatinine: 200 mg/dL
21. Clearance tests used to determine the glomerular filtration
rate must measure substances that are:
A. Not filtered by the glomerulus
C. Reabsorption of sodium and chloride from the
ascending loop of Henle
B. Completely reabsorbed by the proximal convoluted
tubule
D. Reabsorption of water in the descending loop of
Henle
D. Neither reabsorbed or secreted by the tubules
C. Secreted in the distal convoluted tubule
3920_Ch03_039-057 23/01/14 10:10 AM Page 55
Chapter 3 | Renal Function
22. Performing a clearance test using radionucleotides:
A. Eliminates the need to collect urine
29. After controlled fluid intake, the urine-to-serum osmolarity
ratio should be at least:
B. Does not require an infusion
A. 1:1
C. Provides visualization of the filtration
B. 2:1
D. Both A and C
23. Variables that are included in the MDRD-IDSM estimated
creatinine clearance calculations include all of the
following except:
A. Serum creatinine
B. Weight
C. Age
D. Gender
24. An advantage to using cystatin C to monitor GFR is that:
A. It does not require urine collection
B. It is not secreted by the tubules
C. It can be measured by immunoassay
D. All of the above
25. Solute dissolved in solvent will:
A. Raise the vapor pressure
B. Lower the boiling point
C. Decrease the osmotic pressure
D. Lower the freezing point
26. Substances that may interfere with freezing point measurement of urine and serum osmolarity include all of the
following except:
A. Ethanol
B. Lactic acid
C. Sodium
D. Lipids
27. Clinical osmometers use NaCl as a reference solution
because:
A. 1 g molecular weight of NaCl will lower the freezing
point 1.86oC
B. NaCl is readily frozen
C. NaCl is partially ionized similar to the composition
of urine
D. 1 g equivalent weight of NaCl will raise the freezing
point 1.86oC
28. The normal serum osmolarity is:
A. 50 to 100 mOsm
C. 3:1
D. 4:1
30. Calculate the free water clearance from the following
results:
urine volume in 6 hours: 720 mL; urine osmolarity:
225 mOsm; plasma osmolarity: 300 mOsm
31. To provide an accurate measure of renal blood flow, a test
substance should be completely:
A. Filtered by the glomerulus
B. Reabsorbed by the tubules
C. Secreted when it reaches the distal convoluted
tubule
D. Cleared on each contact with functional renal
tissue
32. Given the following data, calculate the effective renal
plasma flow:
urine volume in 2 hours: 240 mL; urine PAH: 150 mg/dL;
plasma PAH: 0.5 mg/dL
33. Renal tubular acidosis can be caused by the:
A. Production of excessively acidic urine due to
increased filtration of hydrogen ions
B. Production of excessively acidic urine due to
increased secretion of hydrogen ions
C. Inability to produce an acidic urine due to impaired
production of ammonia
D. Inability to produce an acidic urine due to increased
production of ammonia
34. Tests performed to detect renal tubular acidosis after
administering an ammonium chloride load include all
of the following except:
A. Urine ammonia
B. Arterial pH
B. 275 to 300 mOsm
C. Urine pH
C. 400 to 500 mOsm
D. Titratable acidity
D. 3 times the urine osmolarity
55
3920_Ch03_039-057 23/01/14 10:10 AM Page 56
56
Part One | Background
Case Studies and Clinical Situations
1. A 44-year-old man diagnosed with acute tubular necrosis
has a blood urea nitrogen of 60 mg/dL and a blood
glucose level of 100 mg/dL. A 2+ urine glucose is also
reported.
a. State the renal threshold for glucose.
b. What is the significance of the positive urine
glucose and normal blood glucose?
2. A patient develops a sudden drop in blood pressure.
a. Diagram the reactions that take place to ensure
adequate blood pressure within the nephrons.
b. How do these reactions increase blood volume?
c. When blood pressure returns to normal, how does the
kidney respond?
3. A physician would like to prescribe a nephrotoxic antibiotic for a 60-year-old Caucasian man. The patient has a
serum creatinine level of 1.5 mg/dL.
a. How can the physician determine whether it is safe to
prescribe this medication before the patient leaves the
office?
b. State two additional blood tests that the physician
could use to continue monitoring this patient.
c. If the patient has a history of prostate malignancy,
would both of these methods provide reliable results?
Explain your answer.
4. A laboratory is obtaining erratic serum osmolarity results
on a patient who is being monitored at 6 a.m., 12 p.m.,
6 p.m., and 12 a.m. Osmolarities are not performed on
the night shift; therefore, the midnight specimen is run at
the same time as the 6 a.m. specimen.
a. What two reasons could account for these
discrepancies?
b. What substance is causing the erratic results?
c. If a friend were secretly bringing the patient a pint of
whiskey every night, would this affect the
results? Explain your answer.
5. Following overnight (6 p.m. to 8 a.m.) fluid deprivation,
the urine-to-serum osmolarity ratio in a patient who is
exhibiting polyuria and polydipsia is 1:1. The ratio remains the same when a second specimen is tested at
10 a.m. ADH is then administered subcutaneously to
the patient, and the fluid deprivation is continued until
2 p.m., when another specimen is tested.
a. What disorder do these symptoms and initial laboratory
results indicate?
b. If the urine-to-serum osmolarity ratio on the 2 p.m.
specimen is 3:1, what is the underlying cause of the
patient’s disorder?
c. If the urine-to-serum osmolarity ratio on the 2 p.m.
specimen remains 1:1, what is the underlying cause of
the patient’s disorder?
3920_Ch03_039-057 23/01/14 10:10 AM Page 57
3920_Ch04_058-070 23/01/14 10:55 AM Page 58
PART T WO
Urinalysis
Chapter 4: Physical Examination of Urine
Chapter 5: Chemical Examination of Urine
Chapter 6: Microscopic Examination of Urine
Chapter 7: Renal Disease
Chapter 8: Urine Screening for Metabolic Disorders
3920_Ch04_058-070 23/01/14 10:55 AM Page 59
CHAPTER
4
Physical Examination of
Urine
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
4-1 List the common terminology used to report normal
urine color.
4-10 List three pathologic and four nonpathologic causes of
cloudy urine.
4-2 Discuss the relationship of urochrome to normal urine
color.
4-11 Define specific gravity, and tell why this measurement
can be significant in the routine analysis.
4-3 State how the presence of bilirubin, biliverdin, uroerythrin, and urobilin in a specimen may be suspected.
4-12 Describe the principles of the refractometer, reagent
strip, and osmolality for determining specific gravity.
4-4 Discuss the significance of cloudy red urine and clear
red urine.
4-13 Given the concentration of glucose and protein in a
specimen, calculate the correction needed to compensate for these high-molecular-weight substances in the
refractometer specific gravity reading.
4-5 Name two pathologic causes of black or brown urine.
4-6 Discuss the significance of phenazopyridine in a
specimen.
4-7 State the clinical significance of urine clarity.
4-8 List the common terminology used to report clarity.
4-9 Describe the appearance and discuss the significance
of amorphous phosphates and amorphous urates in
freshly voided urine.
4-14 Name two nonpathogenic causes of abnormally high
specific gravity readings using a refractometer.
4-15 Describe the advantages of measuring specific gravity
using a reagent strip and osmolality.
4-16 State possible causes of abnormal urine odor.
KEY TERMS
Clarity
Isosthenuric
Urobilin
Hypersthenuric
Refractometry
Urochrome
Hyposthenuric
Specific gravity
Uroerythrin
3920_Ch04_058-070 23/01/14 10:55 AM Page 60
60
Part Two | Urinalysis
The physical examination of urine includes the determination
of the urine color, clarity, and specific gravity. As mentioned
in Chapter 2, early physicians based many medical decisions
on the color and clarity of urine. Today, observation of these
characteristics provides preliminary information concerning
disorders such as glomerular bleeding, liver disease, inborn
errors of metabolism, and urinary tract infection. Measurement
of specific gravity aids in the evaluation of renal tubular function. The results of the physical portion of the urinalysis also
can be used to confirm or to explain findings in the chemical
and microscopic areas of urinalysis.
Color
The color of urine varies from almost colorless to black. These
variations may be due to normal metabolic functions, physical
activity, ingested materials, or pathologic conditions. A noticeable change in urine color is often the reason that a patient
Table 4–1
seeks medical advice; it then becomes the responsibility of the
laboratory to determine whether this color change is normal
or pathologic. The more common normal and pathologic correlations of urine colors are summarized in Table 4–1.
Normal Urine Color
Terminology used to describe the color of normal urine may differ slightly among laboratories but should be consistent within
each laboratory. Common descriptions include pale yellow,
yellow, and dark yellow. Care should be taken to examine the
specimen under a good light source, looking down through
the container against a white background. The yellow color
of urine is caused by the presence of a pigment, which Thudichum named urochrome in 1864. Urochrome is a product of
endogenous metabolism, and under normal conditions the body
produces it at a constant rate. The actual amount of urochrome
produced is dependent on the body’s metabolic state, with increased amounts produced in thyroid conditions and fasting
Laboratory Correlation of Urine Color1
Color
Cause
Clinical/Laboratory Correlations
Colorless
Recent fluid
consumption
Polyuria or diabetes insipidus
Diabetes mellitus
Dilute random specimen
Concentrated specimen
Commonly observed with random specimens
Pale yellow
Dark yellow
B complex vitamins
Dehydration
Bilirubin
Orange-yellow
Yellow-green
Green
Blue-green
Pink
Red
Acriflavine
Nitrofurantoin
Phenazopyridine (Pyridium)
Phenindione
Bilirubin oxidized to
biliverdin
Pseudomonas infection
Amitriptyline
Methocarbamol (Robaxin)
Clorets
Indican
Methylene blue
Phenol
RBCs
Hemoglobin
Increased 24-hour volume and low specific gravity
Elevated specific gravity and positive glucose test result
Recent fluid consumption
May be normal after strenuous exercise or in first morning
specimen
Fever or burns
Yellow foam when shaken and positive chemical test results
for bilirubin
Negative bile test results and possible green fluorescence
Antibiotic administered for urinary tract infections
Drug commonly administered for urinary tract infections
Anticoagulant, orange in alkaline urine, colorless in acid urine
Colored foam in acidic urine and false-negative chemical test
results for bilirubin
Positive urine culture
Antidepressant
Muscle relaxant, may be green-brown
None
Bacterial infections, intestinal disorders
Fistulas
When oxidized
Cloudy urine with positive chemical test results for blood and
RBCs visible microscopically
Clear urine with positive chemical test results for blood;
intravascular hemolysis
3920_Ch04_058-070 23/01/14 10:55 AM Page 61
Chapter 4 | Physical Examination of Urine 61
Table 4–1
Color
Port wine
Red-brown
Brown
Black
Laboratory Correlation of Urine Color1—cont’d
Cause
Clinical/Laboratory Correlations
Myoglobin
Clear urine with positive chemical test results for blood;
muscle damage
Alkaline urine of genetically susceptible persons
Tuberculosis medication
Cloudy specimen with RBCs, mucus, and clots
Negative test for blood, may require additional testing
Seen in acidic urine after standing; positive chemical test
result for blood
Beets
Rifampin
Menstrual contamination
Porphyrins
RBCs oxidized to
methemoglobin
Myoglobin
Homogentisic acid
(alkaptonuria)
Malignant melanoma
Melanin or melanogen
Phenol derivatives
Argyrol (antiseptic)
Methyldopa or levodopa
Metronidazole (Flagyl)
states.2 Urochrome also increases in urine that stands at room
temperature.3
Because urochrome is excreted at a constant rate, the intensity of the yellow color in a fresh urine specimen can give a
rough estimate of urine concentration. A dilute urine will be
pale yellow and a concentrated specimen will be dark yellow.
Remember that, owing to variations in the body’s state of hydration, these differences in the yellow color of urine can be
normal.
Two additional pigments, uroerythrin and urobilin, are
also present in the urine in much smaller quantities, and contribute little to the color of normal, fresh urine. The presence
of uroerythrin, a pink pigment, is most evident in specimens
that have been refrigerated, resulting in the precipitation of
amorphous urates. Uroerythrin attaches to the urates, producing a pink color to the sediment. Urobilin, an oxidation product of the normal urinary constituent urobilinogen, imparts an
orange-brown color to urine that is not fresh.
Abnormal Urine Color
As can be seen in Table 4–1, abnormal urine colors are as
numerous as their causes. Certain colors, however, are seen
more frequently and have a greater clinical significance than
do others.
Dark Yellow/Amber/Orange
Dark yellow or amber urine may not always signify a normal
concentrated urine but can be caused by the presence of
the abnormal pigment bilirubin. If bilirubin is present, it will
be detected during the chemical examination; however, its
Seen in alkaline urine after standing; specific tests are available
Urine darkens on standing and reacts with nitroprusside and
ferric chloride
Interfere with copper reduction tests
Color disappears with ferric chloride
Antihypertensive
Darkens on standing, intestinal and vaginal infections
presence is suspected if yellow foam appears when the specimen is shaken. Normal urine produces only a small amount
of rapidly disappearing foam when shaken, and a large amount
of white foam indicates an increased concentration of protein.
A urine specimen that contains bilirubin may also contain hepatitis virus, reinforcing the need to follow standard precautions.
The photo-oxidation of large amounts of excreted urobilinogen
to urobilin also produces a yellow-orange urine; however,
yellow foam does not appear when the specimen is shaken.
Photo-oxidation of bilirubin imparts a yellow-green color to
the urine caused by the presence of biliverdin.
Also frequently encountered in the urinalysis laboratory
is the yellow-orange specimen caused by the administration of
phenazopyridine (brand name Pyridium) or azo-gantrisin
compounds to people who have urinary tract infections. This
thick, orange pigment not only obscures the natural color of
the specimen but also interferes with chemical tests that are
based on color reactions. It is important to recognize the presence of phenazopyridine in a specimen so that laboratories can
use alternative testing procedures. Specimens containing
phenazopyridine produce a yellow foam when shaken, which
could be mistaken for bilirubin.
Red/Pink/Brown
One of the most common causes of abnormal urine color
is the presence of blood. Red is the usual color that blood
produces in urine, but the color may range from pink to
brown, depending on the amount of blood, the pH of the
urine, and the length of contact. Red blood cells (RBCs) remaining in an acidic urine for several hours produce a brown
3920_Ch04_058-070 23/01/14 10:55 AM Page 62
62
Part Two | Urinalysis
urine due to the oxidation of hemoglobin to methemoglobin.
A fresh brown urine containing blood may also indicate
glomerular bleeding resulting from the conversion of hemoglobin to methemoglobin.4
Besides RBCs, two other substances, hemoglobin and
myoglobin, produce a red urine and result in a positive chemical test result for blood (Fig. 4–1). When RBCs are present,
the urine is red and cloudy; however, if hemoglobin or myoglobin is present, the specimen is red and clear. Distinguishing
between hemoglobinuria and myoglobinuria may be possible
by examining the patient’s plasma. Hemoglobinuria resulting
from the in vivo breakdown of RBCs is accompanied by red
plasma. Breakdown of skeletal muscle produces myoglobin.
Myoglobin is more rapidly cleared from the plasma than is
hemoglobin and, therefore, does not affect the color of the
plasma. Fresh urine containing myoglobin frequently exhibits
a more reddish-brown color than does urine containing hemoglobin. The possibility of hemoglobinuria being produced from
the in vitro lysis of RBCs also must be considered. Chemical
tests to distinguish between hemoglobin and myoglobin are
available (see Chapter 5).
Urine specimens containing porphyrins also may appear
red, resulting from the oxidation of porphobilinogen to
porphyrins. They are often referred to as having the color of
port wine.
Nonpathogenic causes of red urine include menstrual
contamination, ingestion of highly pigmented foods, and
medications. In genetically susceptible persons, eating fresh
beets causes a red color in alkaline urine.5 Ingestion of blackberries can produce a red color in acidic urine. Many medications, including rifampin, phenolphthalein, phenindione, and
phenothiazines, produce red urine.
Brown/Black
Additional testing is recommended for urine specimens that
turn brown or black on standing and have negative chemical
test results for blood, inasmuch as they may contain melanin
or homogentisic acid. Melanin is an oxidation product of the
colorless pigment, melanogen, produced in excess when a
malignant melanoma is present. Homogentisic acid, a metabolite of phenylalanine, imparts a black color to alkaline urine
from persons with the inborn-error of metabolism, called
Red urine
Clear
Hemoglobinuria
Red plasma
Cloudy
Myoglobinuria
Red blood cells present
(Hematuria)
Clear plasma
Figure 4–1 Differentiation of red urine testing chemically positive for
blood.
alkaptonuria. These conditions are discussed in Chapter 7.
Medications producing brown/black urines include levodopa,
methyldopa, phenol derivatives, and metronidazole (Flagyl).
Blue/Green
Pathogenic causes of blue/green urine are limited to bacterial
infections, including urinary tract infection by Pseudomonas
species and intestinal tract infections resulting in increased
urinary indican. Ingestion of breath deodorizers (Clorets) can
result in a green urine.6 The medications methocarbamol
(Robaxin), methylene blue, and amitriptyline (Elavil) may
cause blue urine.
Observation of specimen collection bags from hospitalized
patients frequently reveals abnormally colored urine. This may
signify either a pathologic condition that requires the urine to
stand for a period of time before color development, or the
presence of medications. Phenol derivatives found in certain
intravenous medications produce green urine on oxidation.7
A purple staining may occur in catheter bags and is caused by
indican in the urine or a bacterial infection, frequently caused
by Klebsiella or Providencia species.8
Clarity
“Clarity” is a general term that refers to the transparency or
turbidity of a urine specimen. In routine urinalysis, clarity is
determined in the same manner that ancient physicians used:
by visually examining the mixed specimen while holding it in
front of a light source. The specimen should, of course, be in
a clear container. Color and clarity are routinely determined at
the same time. Common terminology used to report clarity
includes clear, hazy, cloudy, turbid, and milky. As discussed
previously under the section on urine color, terminology
should be consistent within a laboratory. A description of urine
clarity reporting is presented in Table 4–2.
Normal Clarity
Freshly voided normal urine is usually clear, particularly if
it is a midstream clean-catch specimen. Precipitation of
amorphous phosphates and carbonates may cause a white
cloudiness.
Table 4–2
Urine Clarity
Clarity
Term
Clear
Hazy
No visible particulates, transparent
Few particulates, print easily seen through
urine
Many particulates, print blurred through
urine
Print cannot be seen through urine
May precipitate or be clotted
Cloudy
Turbid
Milky
3920_Ch04_058-070 23/01/14 10:55 AM Page 63
Chapter 4 | Physical Examination of Urine 63
PROCEDURE 4-1
Urine Color and Clarity Procedure
1. Evaluate an adequate volume of specimen.
2. Use a well-mixed specimen.
3. View the urine through a clear container.
4. View the urine against a white background using
adequate room lighting.
5. Maintain adequate room lighting
6. Evaluate a consistent volume of urine
• Determine the urine color.
• Describe the urine clarity (Table 4–2).
Nonpathologic Turbidity
The presence of squamous epithelial cells and mucus, particularly in specimens from women, can result in a hazy but normal urine.
Specimens that are allowed to stand or are refrigerated also
may develop turbidity that is nonpathologic. As discussed in
Chapter 2, improper preservation of a specimen results in bacterial growth; this increases specimen turbidity but is not representative of the actual specimen.
Refrigerated specimens frequently develop a thick turbidity
caused by the precipitation of amorphous phosphates, carbonates, and urates. Amorphous phosphates and carbonates produce a white precipitate in urine with an alkaline pH, whereas
amorphous urates produce a precipitate in acidic urine that resembles pink brick dust due to the presence of uroerythrin.
Additional nonpathologic causes of urine turbidity include
semen, fecal contamination, radiographic contrast media, talcum powder, and vaginal creams (Table 4–3).
Pathologic Turbidity
The most commonly encountered pathologic causes of turbidity in a fresh specimen are RBCs, white blood cells
(WBCs), and bacteria caused by infection or a systemic organ
disorder. Other, less frequently encountered causes of pathologic turbidity include abnormal amounts of nonsquamous
Table 4–3
Nonpathologic Causes of Urine Turbidity
Squamous epithelial cells
Mucus
Amorphous phosphates, carbonates, urates
Semen, spermatozoa
Fecal contamination
Radiographic contrast media
Talcum powder
Vaginal creams
epithelial cells, yeast, abnormal crystals, lymph fluid, and
lipids (Table 4–4).
The clarity of a urine specimen certainly provides a key
to the microscopic examination results, because the amount of
turbidity should correspond with the amount of material
observed under the microscope.
Clear urine is not always normal. However, with the increased sensitivity of the routine chemical tests, most abnormalities in clear urine will be detected prior to the microscopic
analysis. Current criteria used to determine the necessity of
performing a microscopic examination on all urine specimens
include both clarity and chemical tests for RBCs, WBCs,
bacteria, and protein.
Specific Gravity
As discussed in Chapter 3, the kidney’s ability to concentrate
the glomerular filtrate by selectively reabsorbing essential
chemicals and water from the glomerular filtrate is one of the
kidney’s most important functions. The evaluation of urine
concentration is included in the routine urinalysis by measuring the specific gravity of the specimen. Including specific gravity in the routine urinalysis provides an additional function,
which is to determine whether specimen concentration is adequate to ensure the accuracy of chemical tests.
The specific gravity of the plasma filtrate entering the
glomerulus is 1.010. The term isosthenuric is used to describe
urine with a specific gravity of 1.010. Specimens below 1.010
are hyposthenuric, and those above 1.010 are hypersthenuric. One would expect urine that has been concentrated
by the kidneys to be hypersthenuric, but this is not always true.
Normal random specimens may range from approximately
1.002 to 1.035, depending on the patient’s amount of hydration. Specimens measuring lower than 1.002 probably are not
urine. Most random specimens fall between 1.015 and 1.030.
Specific gravity is defined as the density of a solution compared with the density of a similar volume of distilled water
(SG 1.000) at a similar temperature. Because urine is actually
water that contains dissolved chemicals, the specific gravity of
urine is a measure of the density of the dissolved chemicals in
the specimen. As a measure of specimen density, specific gravity is influenced not only by the number of particles present
but also by their size. Therefore, large molecules contribute
more to the reading than do the small molecules. This may require the need to correct for the presence of substances that
are not normally seen in urine such as glucose and protein
in the specimen. Currently the only method in use in routine
Table 4–4
Pathologic Causes of Urine Turbidity
RBCs
WBCs
Nonsquamous epithelial cells
Abnormal crystals
Bacteria
Yeast
Lymph fluid
Lipids
3920_Ch04_058-070 23/01/14 10:55 AM Page 64
64
Part Two | Urinalysis
urinalysis that requires correcting is the refractometer. The
other two methods in use are chemical reagent strips and
osmolality. The principles behind current specific gravity measurement techniques are presented in Box 4–1.
Refractometer
Refractometry determines the concentration of dissolved particles in a specimen by measuring refractive index. Refractive
index is a comparison of the velocity of light in air with the
velocity of light in a solution. The concentration of dissolved
particles present in the solution determines the velocity and
angle at which light passes through a solution. Clinical refractometers make use of these principles of light by using a prism
to direct a specific (monochromatic) wavelength of daylight
against a manufacturer-calibrated specific gravity scale. The
concentration of the specimen determines the angle at which
the light beam enters the prism. Therefore, the specific gravity
scale is calibrated in terms of the angles at which light passes
through the specimen.
The refractometer provides the distinct advantage of determining specific gravity using a small volume of specimen
(one or two drops). Temperature corrections are not necessary because the light beam passes through a temperaturecompensating liquid prior to being directed at the specific
gravity scale. Temperature is compensated between 15°C and
38°C. Corrections for glucose and protein must be calculated
by subtracting 0.003 for each gram of protein present and
0.004 for each gram of glucose present. The amount of protein or glucose present can be determined from the chemical
reagent strip tests.
When using the refractometer, a drop of urine is placed
on the prism, the instrument is focused at a good light source,
and the reading is taken directly from the specific gravity scale.
The prism and its cover should be cleaned after each specimen
is tested. Figure 4–2 illustrates the use of the refractometer.
The refractometer is calibrated using distilled water that
should read 1.000. If necessary, the instrument contains a zero
setscrew to adjust the distilled water reading (Fig. 4–3). The
calibration is further checked using 5% NaCl, which as shown
in the refractometer conversion tables should read 1.022 ±
0.001, or 9% sucrose that should read 1.034 ± 0.001. Urine
control samples representing low, medium, and high concentrations should also be run at the beginning of each shift. Calibration and control results are always recorded in the
appropriate quality control records.
Box 4-1
Current Urine Specific Gravity
Measurements
Method
Principle
Refractometry
Refractive index
Osmolality
Changes in colligative properties by particle
number
Reagent strip
pKa changes of a polyelectrolyte by ions present
HISTORICAL NOTE
Urinometry
The urinometer consists of a weighted float attached to a
scale that has been calibrated in terms of urine specific
gravity. The weighted float displaces a volume of liquid
equal to its weight and has been designed to sink to a level
of 1.000 in distilled water. The additional mass provided
by the dissolved substances in urine causes the float to displace a volume of urine smaller than that of distilled water.
The level to which the urinometer sinks, as shown in the
figure, represents the specimen’s mass or specific gravity.
0
10
0
20
10
30
20
40
30
50
40
50
Urinometers representing various specific gravity readings.
Urinometry is less accurate than the other methods
currently available and is not recommended by the
Clinical and Laboratory Standards Institute (CLSI).9
EXAMPLE
A specimen containing 1 g/dL protein and 1 g/dL glucose
has a specific gravity reading of 1.030. Calculate the corrected
reading.
1.030 – 0.003 (protein) = 1.027 – 0.004 (glucose) =
1.023 corrected specific gravity
3920_Ch04_058-070 23/01/14 10:55 AM Page 65
Chapter 4 | Physical Examination of Urine 65
O
1. Put one or two drops of sample
on the prism.
2. Close the daylight plate gently.
1.050
X
3. The sample must spread all over
the prism surface.
1.355
1.040
1.350
1.030
1.345
1.020
X
1.340
1.010
1.335
1.333
1.000
U.G. 20˚C nD
4. Look at the scale through the
eyepiece.
5. Read the scale where the boundary
line intercepts it.
6. Wipe the sample from the prism
clean with a tissue paper and water.
Figure 4–2 Steps in the use of the urine specific gravity refractometer. (Courtesy of NSG Precision Cells, Inc., 195G Central Ave., Farmingdale, NY,
11735.)
Abnormally high results—above 1.040—are seen in patients who have recently undergone an intravenous pyelogram.
This is caused by the excretion of the injected radiographic
contrast media. Patients who are receiving dextran or other
Calibration
screw
high-molecular-weight intravenous fluids (plasma expanders)
also produce urine with an abnormally high specific gravity.
Once the foreign substance has been cleared from the body,
the specific gravity returns to normal. In these circumstances,
urine concentration can be measured using the reagent strip
chemical test or osmometry because they are not affected by
these high-molecular-weight substances.10
Osmolality
As stated previously, specific gravity depends on the number
of particles present in a solution and the density of these particles; osmolality is affected only by the number of particles
present. When evaluating renal concentration ability, the
HISTORICAL NOTE
Harmonic Oscillation Densitometry
Figure 4–3 Calibration of the urine specific gravity refractometer.
(Courtesy of NSG Precision Cells, Inc., 195G Central Ave., Farmingdale,
NY, 11735.)
Harmonic oscillation densitometry is based on the principle that the frequency of a sound wave entering a solution changes in proportion to the density of the solution.
This technique was originally used in early automated urinalysis instruments. The addition of reagent strip analysis
for specific gravity has replaced this technique in automated systems.
3920_Ch04_058-070 23/01/14 10:56 AM Page 66
66
Part Two | Urinalysis
substances of interest are small molecules, primarily sodium
(molecular weight 23) and chloride (molecular weight 35.5).
However, urea (molecular weight 60), which is of no importance to this evaluation, will contribute more to the specific
gravity than will the sodium and chloride molecules. Because
all three molecules contribute equally to the osmolarity of
the specimen, a more representative measure of renal concentrating ability can be obtained by measuring osmolarity
(see Chapter 3).
An osmole is defined as 1 g molecular weight of a substance
divided by the number of particles into which it dissociates. A
nonionizing substance such as glucose (molecular weight, 180)
contains 180 g per osmole, whereas sodium chloride (NaCl)
(molecular weight 58.5), if completely dissociated, contains
29.25 g per osmole. Just like molality and molarity, there are
osmolality and osmolarity. An osmolal solution of glucose has
180 g of glucose dissolved in 1 kg of solvent. An osmolar
solution of glucose has 180 g of glucose dissolved in 1 L of solvent. The unit of measure used in the clinical laboratory is the
milliosmole (mOsm), because it is not practical when dealing
with body fluids to use a measurement as large as the osmole
(23 g of sodium per kilogram).
The osmolarity of a solution can be determined by measuring a property that is mathematically related to the number
of particles in the solution (colligative property) and comparing this value with the value obtained from the pure solvent. Solute dissolved in solvent causes the following changes
in colligative properties: lower freezing point, higher boiling
point, increased osmotic pressure, and lower vapor pressure
(see Table 4–5).
Because water is the solvent in urine the number of particles present in a sample can be determined by comparing a
colligative property value of the sample with that of pure water.
To measure osmolality in the urinalysis laboratory requires special equipment referred to as an osmometer and therefore an
additional step in the routine urinalysis procedure.
TECHNICAL TIP The term “molality” is most commonly
used because the solute and the solvent are both expressed in the same units of measure.
Table 4–5
Particle Changes to Colligative Properties
Property
Freezing Point
Boiling Point
Vapor Pressure
Osmotic
Pressure
Normal Pure
Water Point
Effect of 1 Mole
of Solute
0°C
100°C
2.38 mm/
Hg at 25°C
0 mm/Hg
Lowered 1.86°C
Raised 0.52°C
Lowered 0.3 mm/
Hg at 25°C
Increased 1.7 ×
109 mm/Hg
The A2O Advanced Automated Osmometer (Advanced Instruments, Inc., Two Technology Way, Norwood, MA 02062)
uses freezing point depression to measure osmolality, providing
a more automated method for measuring both urine and serum
osmolality. (The principles and uses of the freezing point and
vapor pressure osmometers currently in use in the clinical laboratory are covered in Chapter 3.)
Additional information on osmometry can be found at
http://www.aitests.com. On the home page click on AI University. A video can also be accessed there.
Reagent Strip Specific Gravity
The addition of a specific gravity testing area to urinalysis
chemical reagent strips has provided a convenient way to perform the routine urinalysis by eliminating the need for an additional procedure.
The reagent strip reaction is based on the change in pKa
(dissociation constant) of a polyelectrolyte in an alkaline
medium. The polyelectrolyte ionizes, releasing hydrogen
ions in proportion to the number of ions in the solution. The
higher the concentration of urine, the more hydrogen ions
are released, thereby lowering the pH. Incorporation of
the indicator bromthymol blue on the reagent pad measures
the change in pH. As the specific gravity increases, the indicator changes from blue (1.000 [alkaline]), through shades
of green, to yellow (1.030 [acid]). Readings can be made
in 0.005 intervals by careful comparison with the color
chart. A diagram of the specific gravity reaction is shown in
Chapter 5, Figure 5.4.
Odor
Although it is seldom of clinical significance and is not a part
of the routine urinalysis, urine odor is a noticeable physical
property. Freshly voided urine has a faint aromatic odor. As the
specimen stands, the odor of ammonia becomes more prominent. The breakdown of urea is responsible for the characteristic ammonia odor. Causes of unusual odors include bacterial
infections, which cause a strong, unpleasant odor similar to
ammonia, and diabetic ketones, which produce a sweet or
fruity odor. A serious metabolic defect results in urine with a
strong odor of maple syrup and is appropriately called maple
syrup urine disease. This and other metabolic disorders with
characteristic urine odors are discussed in Chapter 8. Ingestion
of certain foods, including onions, garlic, and asparagus, can
TECHNICAL TIP Because ions such as Na+, Cl–, and NH4+
are important in evaluating renal concentrating ability, the
reagent strip method provides additional information and
is not affected by nonionizing substances including urea,
glucose, protein, and contaminating substances such as
radiographic dye.
3920_Ch04_058-070 23/01/14 10:56 AM Page 67
Chapter 4 | Physical Examination of Urine 67
cause an unusual or pungent urine odor. Studies have shown
that although everyone who eats asparagus produces an odor,
only certain genetically predisposed people can smell the
odor.11 Common causes of urine odors are summarized in
Table 4–6.
Table 4–6
Possible Causes of Urine Odor1
Odor
Cause
Aromatic
Foul, ammonia-like
Normal
Bacterial decomposition, urinary
tract infection
Ketones (diabetes mellitus,
starvation, vomiting)
Maple syrup urine disease
Phenylketonuria
Tyrosinemia
Isovaleric acidemia
Methionine malabsorption
Contamination
Fruity, sweet
Maple syrup
Mousy
Rancid
Sweaty feet
Cabbage
Bleach
References
1. Henry, JB, Lauzon, RB, and Schumann, GB: Basic examination
of urine. In Henry, JB (ed): Clinical Diagnosis and Management
by Laboratory Methods. WB Saunders, Philadelphia, 1996.
2. Drabkin, DL: The normal pigment of urine: The relationship of
urinary pigment output to diet and metabolism. J Biol Chem
75:443–479, 1927.
3. Ostow, M, and Philo, S: The chief urinary pigment: The relationship between the rate of excretion of the yellow pigment
and the metabolic rate. Am J Med Sci 207:507–512, 1944.
4. Berman, L: When urine is red. JAMA 237:2753–2754, 1977.
5. Reimann, HA: Re: Red urine. JAMA 241(22):2380, 1979.
6. Evans, B: The greening of urine: Still another “Cloret sign.”
N Engl J Med 300(4):202, 1979.
7. Bowling, P, Belliveau, RR, and Butler, TJ: Intravenous medications and green urine. JAMA 246(3):216, 1981.
8. Dealler, SF, et al: Purple urine bags. J Urol 142(3):769–770,
1989.
9. Clinical and Laboratory Standards Institute (Formerly NCCLS)
Approved Guideline GP16-A3: Urinalysis and Collection,
Transportation, and Preservation of Urine Specimens;
Approved Guideline, ed 3, CLSI, Wayne, PA, 2009.
10. Smith, C, Arbogast, C, and Phillips, R: Effect of x-ray contrast
media on results for relative density of urine. Clin Chem
19(4):730–731, 1983.
11. Mitchell, SC, et al: Odorous urine following asparagus ingestion in man. Experimenta 43(4):382–383, 1987.
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
Study Questions
1. The concentration of a normal urine specimen can be
estimated by which of the following?
A. Color
B. Clarity
C. Foam
D. Odor
2. The normal yellow color of urine is produced by:
A. Bilirubin
B. Hemoglobin
C. Urobilinogen
D. Urochrome
3. The presence of bilirubin in a urine specimen produces a:
A. Yellow foam when shaken
B. White foam when shaken
C. Cloudy specimen
D. Yellow-red specimen
4. A urine specimen containing melanin will appear:
A. Pale pink
B. Dark yellow
C. Blue-green
D. Black
5. Specimens that contain hemoglobin can be visually distinguished from those that contain RBCs because:
A. Hemoglobin produces a clear, yellow specimen
B. Hemoglobin produces a cloudy pink specimen
C. RBCs produce a cloudy red specimen
D. RBCs produce a clear red specimen
6. A patient with a viscous orange specimen may have been:
A. Treated for a urinary tract infection
B. Taking vitamin B pills
C. Eating fresh carrots
D. Taking antidepressants
3920_Ch04_058-070 23/01/14 10:56 AM Page 68
68
Part Two | Urinalysis
7. The presence of a pink precipitate in a refrigerated specimen is caused by:
A. Hemoglobin
B. Urobilin
C. Uroerythrin
D. Beets
8. Microscopic examination of a clear urine that produces a
white precipitate after refrigeration will show:
A. Amorphous urates
B. Porphyrins
C. Amorphous phosphates
D. Yeast
9. The color of urine containing porphyrins will be:
A. Yellow-brown
B. Green
C. Orange
D. Port wine
10. Which of the following specific gravities would be most
likely to correlate with a pale yellow urine?
A. 1.005
B. 1.010
C. 1.020
D. 1.030
11. A urine specific gravity measured by refractometer is
1.029, and the temperature of the urine is 14°C. The specific gravity should be reported as:
A. 1.023
B. 1.027
C. 1.029
D. 1.032
12. The principle of refractive index is to compare:
A. Light velocity in solutions with light velocity in
solids
B. Light velocity in air with light velocity in solutions
C. Light scattering by air with light scattering by
solutions
D. Light scattering by particles in solution
13. A correlation exists between a specific gravity by refractometer of 1.050 and a:
A. 2+ glucose
B. 2+ protein
C. First morning specimen
D. Radiographic dye infusion
14. A cloudy urine specimen turns black upon standing and
has a specific gravity of 1.012. The major concern about
this specimen would be:
A. Color
B. Turbidity
C. Specific gravity
D. All of the above
15. A specimen with a specific gravity of 1.035 would be considered:
A. Isosthenuric
B. Hyposthenuric
C. Hypersthenuric
D. Not urine
16. A specimen with a specific gravity of 1.001 would be considered:
A. Hyposthenuric
B. Not urine
C. Hypersthenuric
D. Isosthenuric
17. A strong odor of ammonia in a urine specimen could
indicate:
A. Ketones
B. Normalcy
C. Phenylketonuria
D. An old specimen
18. The microscopic of a clear red urine is reported as many
WBCs and epithelial cells. What does this suggest?
A. Urinary tract infection
B. Dilute random specimen
C. Hematuria
D. Possible mix-up of specimen and sediment
19. Which of the following would contribute the most to a
urine osmolality?
A. One osmole of glucose
B. One osmole of urea
C. One osmole of sodium chloride
D. All contribute equally
20. Which of the following colligative properties is not stated
correctly?
A. The boiling pointing is raised by solute
B. The freezing point is raised by solute
C. The vapor pressure is lowered by solute
D. The osmotic pressure is raised by solute
3920_Ch04_058-070 23/01/14 10:56 AM Page 69
Chapter 4 | Physical Examination of Urine 69
21. An osmole contains:
A. One gram molecular weight of solute dissolved in
one liter of solvent
B. One gram molecular weight of solute dissolved
in one kilogram of solvent
C. Two gram molecular weights of solute dissolved in
one liter of solvent
D. Two gram molecular weights of solute dissolved
in one kilogram of solvent
22. The unit of osmolality measured in the clinical laboratory
is the:
A. Osmole
B. Milliosmole
C. Molecular weight
D. Ionic charge
23. In the reagent strip specific gravity reaction the
polyelectrolyte:
A. Combines with hydrogen ions in response to ion
concentration
B. Releases hydrogen ions in response to ion
concentration
C. Releases hydrogen ions in response to pH
D. Combines with sodium ions in response to pH
24. Which of the following will react in the reagent strip
specific gravity test?
A. Glucose
B. Radiographic dye
C. Protein
D. Chloride
Case Studies and Clinical Situations
1. Given the following physical urinalysis results, determine
additional urinalysis results that may be abnormal.
a. A green specimen with a strong foul odor of ammonia
b. A pale yellow urine with a specific gravity of 1.030
c. A dark yellow specimen with yellow foam
d. A cloudy red urine
c. If the specific gravity was also checked using osmometry, should the result agree with the laboratory or the
urology clinic results? Why or why not?
3. State two pathologic causes of a clear red urine.
a. State a method that could distinguish between the two
causes that does not require laboratory testing.
a. Correct the refractometer reading to account for the
protein and glucose concentrations. What is the corrected specific gravity?
4. Mrs. Smith frequently shops at the farmer’s market near
her home. She notices her urine has a red color and
brings a sample to her physician. The specimen tests
negative for blood.
a. What is a probable cause of Mrs. Smith’s red urine?
b. Mrs. Smith collects a specimen at the physician’s
office. The color is yellow and the pH is 5.5. Is
this consistent with the previous answer? Why or
why not?
b. Do the specific gravities correlate?
5. Is a clear urine always normal? Explain your answer.
2. The urology clinic questions a urinalysis report from the
laboratory.
The laboratory report states that a reagent strip reading
of a specific gravity of 1.020, protein 3 g/dL, and glucose
2 g/dL. The specific gravity in the urology clinic was
greater than 1.035.
3920_Ch04_058-070 23/01/14 10:56 AM Page 70
3920_Ch05_071-098 23/01/14 10:13 AM Page 71
CHAPTER
5
Chemical Examination of
Urine
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
5-1 Describe the proper technique for performing reagent
strip testing.
5-2 List four causes of premature deterioration of reagent
strips, and describe how to avoid them.
5-3 List five quality-control procedures routinely performed with reagent strip testing.
5-4 List the reasons for measuring urinary pH, and discuss
their clinical applications.
5-5 Discuss the principle of pH testing by reagent strip.
5-6 Differentiate between prerenal, renal, and postrenal
proteinuria, and give clinical examples of each.
5-7 Explain the “protein error of indicators,” and list any
sources of interference that may occur with this
method of protein testing.
5-8 Discuss microalbuminuria including significance,
reagent strip tests, and their principles.
5-9 Explain why glucose that is normally reabsorbed in
the proximal convoluted tubule may appear in the
urine, and state the renal threshold levels for glucose.
5-10 Describe the principle of the glucose oxidase method
of reagent strip testing for glucose, and name possible
causes of interference with this method.
5-11 Describe the copper reduction method for detection of
urinary reducing substances, and discuss the current
use of this procedure.
5-14 Differentiate between hematuria, hemoglobinuria, and
myoglobinuria with regard to the appearance of urine
and serum and clinical significance.
5-15 Describe the chemical principle of the reagent strip
method for blood testing, and list possible causes of
interference.
5-16 Outline the steps in the degradation of hemoglobin to
bilirubin, urobilinogen, and finally urobilin.
5-17 Describe the relationship of urinary bilirubin and urobilinogen to the diagnosis of bile duct obstruction,
liver disease, and hemolytic disorders.
5-18 Discuss the principle of the reagent strip test for urinary bilirubin, including possible sources of error.
5-19 State two reasons for increased urine urobilinogen and
one reason for a decreased urine urobilinogen.
5-20 Discuss the principle of the nitrite-reagent-strip test
for bacteriuria.
5-21 List five possible causes of a false-negative result in the
reagent strip test for nitrite.
5-22 State the principle of the reagent strip test for
leukocytes.
5-23 Discuss the advantages and sources of error of the
reagent strip test for leukocytes.
5-24 Explain the principle of the chemical test for specific
gravity.
5-12 Name the three “ketone bodies” appearing in urine
and three causes of ketonuria.
5-25 Compare reagent strip testing for urine specific gravity
with osmolality and refractometer testing.
5-13 Discuss the principle of the sodium nitroprusside
reaction to detect ketones, including sensitivity and
possible causes of interference.
5-26 Correlate physical and chemical urinalysis results.
3920_Ch05_071-098 23/01/14 10:13 AM Page 72
72
Part Two | Urinalysis
KEY TERMS
Bacteriuria
Hemosiderin
Postrenal proteinuria
Bilirubin
Jaundice
Prerenal proteinuria
Fanconi syndrome
Ketonuria
Protein error of indicators
Ferritin
Leukocyturia
Proteinuria
Glycosuria
Microalbuminuria
Stercobilinogen
Hematuria
Myoglobinuria
Urobilinogen
Hemoglobinuria
Orthostatic proteinuria
Uromodulin
Reagent Strips
Routine chemical examination of urine has changed dramatically since the early days of urine testing, due to the development of the reagent strip method for chemical analysis.
Reagent strips currently provide a simple, rapid means for
performing medically significant chemical analysis of urine,
including pH, protein, glucose, ketones, blood, bilirubin,
urobilinogen, nitrite, leukocytes, and specific gravity. The
two major types of reagent strips are manufactured under
the trade names Multistix (Siemens Healthcare Diagnostics,
Deerfield, IN) and Chemstrip (Roche Diagnostics, Indianapolis,
IN). These products are available with single-or multipletesting areas, and the brand and number of tests used are a matter of laboratory preference. Certain variations relating to chemical reactions, sensitivity, specificity, and interfering substances
occur among the products and are discussed in the following
sections. Reagent strip brands are also specified by instrumentation manufacturers.
Reagent strips consist of chemical-impregnated absorbent
pads attached to a plastic strip. A color-producing chemical reaction takes place when the absorbent pad comes in contact
with urine. The reactions are interpreted by comparing the
color produced on the pad within the required time frame with
a chart supplied by the manufacturer. Several colors or intensities of a color for each substance being tested appear on the
chart. By careful comparison of the colors on the chart and the
strip, a semiquantitative value of trace, 1+, 2+, 3+, or 4+ can
be reported. An estimate of the milligrams per deciliter present
is available for appropriate testing areas. Automated reagent
strip readers also provide Système International units.
Reagent Strip Technique
Testing methodology includes dipping the reagent strip completely, but briefly, into a well-mixed specimen, removing excess urine from the strip by running the edge of the strip on
the container when withdrawing it from the specimen, blotting
it horizontally on an absorbent medium, waiting the specified
length of time for reactions to take place, and comparing the
colored reactions against the manufacturer’s chart using a good
light source.
Errors Caused by Improper Technique
1. Formed elements such as red and white blood cells sink
to the bottom of the specimen and will be undetected in
an unmixed specimen.
2. Allowing the strip to remain in the urine for an extended
period may cause leaching of reagents from the pads.
3. Excess urine remaining on the strip after its removal
from the specimen can produce a run-over between
chemicals on adjacent pads, producing distortion of
the colors. To ensure against run-over, blotting the edge
of the strip on absorbent paper and holding the strip
horizontally while comparing it with the color chart is
recommended.
4. The timing for reactions to take place varies between
tests and manufacturers, and ranges from an immediate
reaction for pH to 120 seconds for leukocyte esterase.
For the best semiquantitative results, the manufacturer’s
stated time should be followed; however, when precise
timing cannot be achieved, manufacturers recommend
that reactions be read between 60 and 120 seconds, with
the leukocyte esterase reaction read at 120 seconds.
5. A good light source is essential for accurate interpretation of color reactions.
PROCEDURE 5-1
Reagent Strip Technique1,2
1. Dip the reagent strip briefly into a well-mixed uncentrifuged urine specimen at room temperature.
2. Remove excess urine by touching the edge of the
strip to the container as the strip is withdrawn.
3. Blot the edge of the strip on a disposable absorbent
pad.
4. Wait the specified amount of time for the reaction to
occur.
5. Compare the color reaction of the strip pads to the
manufacturer’s color chart in good lighting.
3920_Ch05_071-098 23/01/14 10:13 AM Page 73
Chapter 5 | Chemical Examination of Urine 73
6. The strip must be held close to the color chart without
actually being placed on the chart. Automated reagent
strip instruments standardize the color interpretation
and timing of the reaction and are not subject to room
lighting deficiencies or inconsistency among laboratory
personnel (Appendix A).
7. Reagent strips and color charts from different manufacturers are not interchangeable.
8. Specimens that have been refrigerated must be allowed
to return to room temperature prior to reagent strip
testing, as the enzymatic reactions on the strips are temperature dependent.
Handling and Storing Reagent Strips
In addition to using correct testing technique, reagent strips
must be protected from deterioration caused by moisture,
volatile chemicals, heat, and light. Reagent strips are packaged
in opaque containers with a desiccant to protect them from
light and moisture. Strips are removed just prior to testing, and
the bottle is tightly resealed immediately. Bottles should not be
opened in the presence of volatile fumes. Manufacturers recommend that reagent strips be stored at room temperature
below 30°C (but never refrigerated). All bottles are stamped
with an expiration date that represents the functional life expectancy of the chemical pads. Reagent strips must not be used
past the expiration date. Care must be taken not to touch the
chemical pads when removing the strips. A visual inspection
of the strip should be done each time a strip is used to detect
deterioration, even though the strips may still be within the
expiration date.
Quality Control of Reagent Strips
Reagent strips must be checked with both positive and negative
controls a minimum of once every 24 hours. Many laboratories
perform this check at the beginning of each shift. Testing is
also performed when a new bottle of reagent strips is opened,
questionable results are obtained, or there is concern about the
integrity of the strips. All quality control results must be
recorded following laboratory protocol. Several companies
manufacture both positive and negative controls. Distilled
water is not recommended as a negative control because
reagent strip chemical reactions are designed to perform at
ionic concentrations similar to urine. All readings of the negative control must be negative, and positive control readings
should agree with the published value. Results that do not
agree with the published values must be resolved through the
testing of additional strips and controls (see Chapter 1).
Demonstration of chemically acceptable reagent strips
does not entirely rule out the possibility of inaccurate results.
Interfering substances in the urine, technical carelessness, and
color blindness also produce errors. Reagent strip manufacturers have published information concerning the limitations
(e.g., interfering substances, sensitivities) of their chemical reactions, and laboratory personnel should be aware of these
conditions. As mentioned in Chapter 4, a primary example of
reagent strip interference is the masking of color reactions by
the orange pigment present in the urine of persons taking
phenazopyridine compounds. If laboratory personnel do not
recognize the presence of this pigment or other pigments, they
will report many erroneous results.
Confirmatory Testing
Confirmatory tests are defined as test using different reagents
or methodologies to detect the same substances as detected
by the reagent strips with the same or greater sensitivity or
specificity.4
Nonreagent strip testing procedures using tablets and
liquid chemicals may be available when questionable results
are obtained or highly pigmented specimens are encountered.
In the past, many of these procedures were used routinely to
confirm positive results. Increased specificity and sensitivity
of reagent strips and the use of automated strip readers have
reduced the need for routine use of these procedures.5,6 The
chemical reliability of these procedures also must be checked
using positive and negative controls.
Specific confirmatory tests are discussed in this chapter
under their specific sections or the Historical Notes devoted to
the chemical parameters for which they are used. The principles and procedures for these tests are included to provide additional information on the principles of the reagent strips and
to provide the methodology to perform these tests if necessary.
Institutional protocol will determine the situations when they
should be performed.
pH
Along with the lungs, the kidneys are the major regulators of
the acid–base content in the body. They do this through the
secretion of hydrogen in the form of ammonium ions, hydrogen phosphate, and weak organic acids, and by the reabsorption of bicarbonate from the filtrate in the convoluted tubules
(see Chapter 2). A healthy individual usually produces a first
morning specimen with a slightly acidic pH of 5.0 to 6.0; a
more alkaline pH is found following meals (alkaline tide). The
pH of normal random samples can range from 4.5 to 8.0. Consequently, no normal values are assigned to urinary pH, and
it must be considered in conjunction with other patient
information, such as the acid–base content of the blood, the
patient’s renal function, the presence of a urinary tract infection, the patient’s dietary intake, and the age of the specimen
(Table 5–1).
Clinical Significance
The importance of urinary pH is primarily as an aid in determining the existence of systemic acid–base disorders of
metabolic or respiratory origin and in the management of
urinary conditions that require the urine to be maintained
at a specific pH. In respiratory or metabolic acidosis not related to renal function disorders, the urine is acidic; conversely, if respiratory or metabolic alkalosis is present, the
3920_Ch05_071-098 23/01/14 10:14 AM Page 74
74
Part Two | Urinalysis
SUMMARY 5-1
Reagent Strip Testing
Table 5–1
Causes of Acid and Alkaline Urine
Care of Reagent Strips
Acid Urine
Alkaline Urine
1. Store with desiccant in an opaque, tightly closed
container.
2. Store below 30°C; do not freeze.
3. Do not expose to volatile fumes.
4. Do not use past the expiration date.
5. Do not use if chemical pads become discolored.
6. Remove strips immediately prior to use.
Technique
1. Mix specimen well.
2. Let refrigerated specimens warm to room temperature before testing.
3. Dip the strip completely, but briefly, into specimen.
4. Remove excess urine by withdrawing the strip against
the rim of the container and by blotting the edge of
the strip.
Emphysema
Diabetes mellitus
Starvation
Dehydration
Hyperventilation
Vomiting
Renal tubular acidosis
Presence of ureaseproducing bacteria
Vegetarian diet
Old specimens
5. Compare reaction colors with the manufacturer’s
chart under a good light source at the specified time.
6. Perform backup tests when indicated.
7. Be alert for the presence of interfering substances.
8. Understand the principles and significance of the test;
read package inserts.
9. Relate chemical findings to each other and to the
physical and microscopic urinalysis results.
Quality Control
1. Test open bottles of reagent strips with known positive and negative controls every 24 hours.
2. Resolve control results that are out of range by further
testing.
3. Test reagents used in backup tests with positive and
negative controls.
4. Perform positive and negative controls on new
reagents and newly opened bottles of reagent strips.
5. Record all control results and reagent lot numbers.
urine is alkaline. Therefore, a urinary pH that does not conform to this pattern may be used to rule out the suspected
condition, or, as discussed in Chapter 3, it may indicate a
disorder resulting from the kidneys’ inability to secrete or to
reabsorb acid or base.
The precipitation of inorganic chemicals dissolved in the
urine forms urinary crystals and renal calculi. This precipitation depends on urinary pH and can be controlled by maintaining the urine at a pH that is incompatible with the
precipitation of the particular chemicals causing the calculi
formation. For example, calcium oxalate, a frequent constituent of renal calculi, precipitates primarily in acidic and
not alkaline urine. Therefore, maintaining urine at an alkaline
Diarrhea
Presence of acid-producing
bacteria (Escherichia coli)
High-protein diet
Cranberry juice
Medications (methenamine
mandelate [Mandelamine],
fosfomycin tromethamine
[Monurol])
pH discourages formation of the calculi. Knowledge of urinary
pH is important in the identification of crystals observed during microscopic examination of the urine sediment. This will
be discussed in detail in Chapter 6.
Maintaining an acidic urine can be valuable in treating
urinary tract infections caused by urea-splitting organisms
because they do not multiply as readily in an acidic medium.
These same organisms are also responsible for the highly
alkaline pH found in specimens that have been allowed to sit
unpreserved for extended periods. Urinary pH is controlled
primarily by dietary regulation, although medications also
may be used. Persons on high-protein and high-meat diets
tend to produce acidic urine, whereas urine from vegetarians
is more alkaline, due to the formation of bicarbonate following
digestion of many fruits and vegetables. An exception to the
rule is cranberry juice, which produces an acidic urine and
has long been used as a home remedy for minor bladder infections because it inhibits the colonization of certain urinary
pathogens. People who are prone to frequent urinary tract infections are often advised to drink cranberry juice or take
over-the-counter cranberry pills. Medications prescribed for
urinary tract infections, such as methenamine mandelate
(Mandelamine) and fosfomycin tromethamine (Monurol) are
metabolized to produce an acidic urine.
The pH of freshly excreted urine does not reach above 8.5
in normal or abnormal conditions. A pH above 8.5 is associated with an improperly preserved specimen and indicates that
a fresh specimen should be obtained to ensure the validity of
the analysis.
TECHNICAL TIP Collecting specimens in containers
other than the single-use laboratory-supplied containers
can produce a pH above 8.5 if alkaline detergent remains
in the container.
3920_Ch05_071-098 23/01/14 10:14 AM Page 75
Chapter 5 | Chemical Examination of Urine 75
Clinical Significance of
Urine pH
SUMMARY 5-2
Respiratory or metabolic acidosis/ketosis
Respiratory or metabolic alkalosis
Defects in renal tubular secretion and reabsorption of
acids and bases—renal tubular acidosis
Renal calculi formation and prevention
Treatment of urinary tract infections
Precipitation/identification of crystals
Determination of unsatisfactory specimens
Reagent Strip Reactions
The Multistix and Chemstrip brands of reagent strips measure
urine pH in 0.5- or 1-unit increments between pH 5 and 9. To
differentiate pH units throughout this wide range, both manufacturers use a double-indicator system of methyl red and
bromthymol blue. Methyl red produces a color change from
red to yellow in the pH range 4 to 6, and bromthymol blue
turns from yellow to blue in the range of 6 to 9. Therefore, in
the pH range 5 to 9 measured by the reagent strips, one sees
colors progressing from orange at pH 5 through yellow and
green to a final deep blue at pH 9.
H+
Methyl red +
(Red-orange →
H+
→ bromthymol blue –
yellow) (green → blue)
No known substances interfere with urinary pH measurements performed by reagent strips.
TECHNICAL TIP Care must be taken to prevent run-over
between the pH testing area and the adjacent, highly
acidic protein testing area on Multistix, as this may produce a falsely acidic reading in an alkaline urine.
SUMMARY 5-3
Reagents
Sensitivity
Sources of error/
interference:
Correlations with
other tests:
pH Reagent Strip
Methyl red, bromthymol blue
Multistix: 5.0 to 8.5 in 0.5 increments
Chemstrip: 5.0 to 9.0 in 1.0 increments
No known interfering substances
Run-over from adjacent pads
Old specimens
Nitrite
Leukocytes
Microscopic
Protein
Of the routine chemical tests performed on urine, the most indicative of renal disease is the protein determination. Proteinuria
is often associated with early renal disease, making the urinary
protein test an important part of any physical examination. Normal urine contains very little protein: usually, less than 10 mg/dL
or 100 mg per 24 hours is excreted. This protein consists primarily of low-molecular-weight serum proteins that have been
filtered by the glomerulus and proteins produced in the genitourinary tract. Due to its low molecular weight, albumin is the
major serum protein found in normal urine. Even though it is
present in high concentrations in the plasma, the normal urinary albumin content is low because the majority of albumin
presented to the glomerulus is not filtered, and much of the
filtered albumin is reabsorbed by the tubules. Other proteins
include small amounts of serum and tubular microglobulins;
Tamm-Horsfall protein (uromodulin) produced by the renal
tubular epithelial cells; and proteins from prostatic, seminal,
and vaginal secretions. (Uromodulin is a more recent name for
Tamm-Horsfall protein. Uromodulin is routinely produced in
the distal convoluted tubule. As will be discussed in Chapter 6,
uromodulin forms the matrix of casts formed in the distal convoluted tubule.)
Clinical Significance
Demonstration of proteinuria in a routine analysis does not
always signify renal disease; however, its presence does require
additional testing to determine whether the protein represents
a normal or a pathologic condition. Clinical proteinuria is indicated at 30 mg/dL or greater (300 mg/L).7 The causes of proteinuria are varied and can be grouped into three major
categories: prerenal, renal, and postrenal, based on the origin
of the protein.
Prerenal Proteinuria
As the name implies, prerenal proteinuria is caused by conditions affecting the plasma prior to its reaching the kidney
and, therefore, is not indicative of actual renal disease. This
condition is frequently transient, caused by increased levels of
low-molecular-weight plasma proteins such as hemoglobin,
myoglobin, and the acute phase reactants associated with
infection and inflammation. The increased filtration of these
proteins exceeds the normal reabsorptive capacity of the renal
tubules, resulting in an overflow of the proteins into the urine.
Because reagent strips detect primarily albumin, prerenal proteinuria is usually not discovered in a routine urinalysis.
Bence Jones Protein
A primary example of proteinuria due to increased serum protein levels is the excretion of Bence Jones protein by persons
with multiple myeloma. In multiple myeloma, a proliferative
disorder of the immunoglobulin-producing plasma cells, the
serum contains markedly elevated levels of monoclonal immunoglobulin light chains (Bence Jones protein). This lowmolecular-weight protein is filtered in quantities exceeding
the tubular reabsorption capacity and is excreted in the urine.
3920_Ch05_071-098 23/01/14 10:14 AM Page 76
76
Part Two | Urinalysis
Suspected cases of multiple myeloma must be diagnosed by
performing serum electrophoresis and immunoelectrophoresis. The screening test for Bence Jones protein is not routinely
performed, as cases of multiple myeloma are easily detected
by chemical methods (see the Historical Note, Screening Test
for Bence Jones Protein).
Renal Proteinuria
Proteinuria associated with true renal disease may be the result
of either glomerular or tubular damage.
Glomerular Proteinuria
When the glomerular membrane is damaged, selective filtration
is impaired, and increased amounts of serum protein and eventually red and white blood cells pass through the membrane
and are excreted in the urine. Conditions that present the
glomerular membrane with abnormal substances (e.g., amyloid
material, toxic substances, and the immune complexes found
in lupus erythematosus and streptococcal glomerulonephritis)
are major causes of proteinuria due to glomerular damage.
Increased pressure from the blood entering the glomerulus
may override the selective filtration of the glomerulus, causing
increased albumin to enter the filtrate. This condition may be
reversible, such as occurs during strenuous exercise and dehydration or is associated with hypertension. Proteinuria that
occurs during the latter months of pregnancy may indicate a
pre-eclamptic state and should be considered by the physician
in conjunction with other clinical symptoms, such as hypertension, to determine if this condition exists.
The discovery of protein, particularly in a random sample,
is not always of pathologic significance, because several benign
causes of renal proteinuria exist. Benign proteinuria is usually
transient and can be produced by conditions such as strenuous
exercise, high fever, dehydration, and exposure to cold.
Microalbuminuria
The development of diabetic nephropathy leading to reduced
glomerular filtration and eventual renal failure is a common
HISTORICAL NOTE
Screening Test for Bence Jones
Protein
Unlike other proteins, which coagulate and remain coagulated when exposed to heat, Bence Jones protein coagulates
at temperatures between 40°C and 60°C and dissolves
when the temperature reaches 100°C. Therefore, a specimen that appears turbid between 40°C and 60°C and clear
at 100°C can be suspected of containing Bence Jones protein. Interference due to other precipitated proteins can
be removed by filtering the specimen at 100°C and observing the specimen for turbidity as it cools to between 40°C
and 60°C.
occurrence in persons with both type 1 and type 2 diabetes
mellitus. Onset of renal complications can first be predicted
by detection of microalbuminuria, and the progression of
renal disease can be prevented through better stabilization
of blood glucose levels and control of hypertension. The presence of microalbuminuria is also associated with an increased
risk of cardiovascular disease. 8, 9
Orthostatic (Postural) Proteinuria
A persistent benign proteinuria occurs frequently in young
adults and is termed orthostatic proteinuria, or postural
proteinuria. It occurs following periods spent in a vertical posture and disappears when a horizontal position is assumed.
Increased pressure on the renal vein when in the vertical
position is believed to account for this condition. Patients suspected of orthostatic proteinuria are requested to empty the
bladder before going to bed, collect a specimen immediately
upon arising in the morning, and collect a second specimen
after remaining in a vertical position for several hours. Both
specimens are tested for protein, and if orthostatic proteinuria
is present, a negative reading will be seen on the first morning
specimen, and a positive result will be found on the second
specimen.
Tubular Proteinuria
Increased albumin is also present in disorders affecting tubular reabsorption because the normally filtered albumin can
no longer be reabsorbed. Other low-molecular-weight proteins that are usually reabsorbed are also present. Causes of
tubular dysfunction include exposure to toxic substances and
heavy metals, severe viral infections, and Fanconi syndrome.
The amount of protein that appears in the urine following
glomerular damage ranges from slightly above normal to
4 g/day, whereas markedly elevated protein levels are seldom
seen in tubular disorders.
Postrenal Proteinuria
Protein can be added to a urine specimen as it passes through
the structures of the lower urinary tract (ureters, bladder, urethra, prostate, and vagina). Bacterial and fungal infections
HISTORICAL NOTE
Microalbuminuria Testing
Before the development of current reagent strip methods
that are specific for albumin, detection of microalbuminuria required collection of a 24-hour urine specimen.
Specimens were tested using quantitative procedures for
albumin. Results were reported in mg of albumin/24 hours
or as the albumin excretion (AER) in µg/min. With these
methods, microalbumin was considered significant when
30 to 300 mg of albumin is excreted in 24 hours or the
AER is 20 to 200 µg/min.
3920_Ch05_071-098 23/01/14 10:14 AM Page 77
Chapter 5 | Chemical Examination of Urine 77
and inflammations produce exudates containing protein from
the interstitial fluid. The presence of blood as the result of
injury or menstrual contamination contributes protein, as
does the presence of prostatic fluid and large amounts of
spermatozoa.
Reagent Strip Reactions
Traditional reagent strip testing for protein uses the principle
of the protein error of indicators to produce a visible colorimetric reaction. Contrary to the general belief that indicators
produce specific colors in response to particular pH levels,
certain indicators change color in the presence of protein even
though the pH of the medium remains constant. This is because protein (primarily albumin) accepts hydrogen ions from
the indicator. The test is more sensitive to albumin because
albumin contains more amino groups to accept the hydrogen
ions than other proteins. Depending on the manufacturer, the
protein area of the strip contains either tetrabromophenol blue
(Multistix) or 3',3",5',5"-tetrachlorophenol, 3,4,5,6-tetrabromosulfonphthalein (Chemstrip), and an acid buffer to maintain the pH at a constant level. At a pH level of 3, both
indicators appear yellow in the absence of protein; however,
as the protein concentration increases, the color progresses
through various shades of green and finally to blue. Readings
are reported in terms of negative, trace, 1+, 2+, 3+, and 4+;
or the semiquantitative values of 30, 100, 300, or 2000 mg/dL
corresponding to each color change. Trace values are considered to be less than 30 mg/dL. Interpretation of trace readings
SUMMARY 5-4
Clinical Significance of
Urine Protein
Prerenal
Intravascular hemolysis
Muscle injury
Acute phase reactants
Multiple myeloma
Tubular Disorders
Fanconi syndrome
Toxic agents/heavy metals
Severe viral infections
Renal
Glomerular disorders
Postrenal
Lower urinary tract infections/
inflammation
Injury/trauma
Immune complex
disorders
Amyloidosis
Menstrual contamination
Toxic agents
Prostatic fluid/spermatozoa
Diabetic nephropathy
Vaginal secretions
Strenuous exercise
Dehydration
Hypertension
Pre-eclampsia
Orthostatic or postural proteinuria
can be difficult. Reporting of trace values may be a laboratory
option.
Indicator + protein
(Yellow)
pH 3.0
protein + H+
indicator – H+
(blue-green)
Reaction Interference
The major source of error with reagent strips occurs with highly
buffered alkaline urine that overrides the acid buffer system, producing a rise in pH and a color change unrelated to protein concentration. Likewise, a technical error of allowing the reagent
pad to remain in contact with the urine for a prolonged period
may remove the buffer. False-positive readings are obtained
when the reaction does not take place under acidic conditions.
Highly pigmented urine and contamination of the container with
quaternary ammonium compounds, detergents, and antiseptics
also cause false-positive readings. A false-positive trace reading
may occur in specimens with a high specific gravity.
Sulfosalicylic Acid Precipitation Test
The sulfosalicylic acid (SSA) test is a cold precipitation test
that reacts equally with all forms of protein. Various concentrations and amounts of SSA can be used to precipitate protein,
and methods vary greatly among laboratories. All precipitation
tests must be performed on centrifuged specimens to remove
any extraneous contamination. Based on the protocol of the
laboratory, an SSA test may be performed in certain situations.
The procedure is included in this section to serve as a reference
if needed (Procedure 5–2).5
Testing for Microalbuminuria
Several semiquantitative reagent strip methods have been
developed so that patients at risk for renal disease can be
monitored using random or first morning specimens. These
methods are based on immunochemical assays for albumin or
albumin-specific reagent strips that also measure creatinine to
produce an albumin:creatinine ratio.
Immunochemical assays include the Micral-Test (Roche
Diagnostics, Indianapolis, IN) and the ImmunoDip (Sakisui
Diagnostics, Framingham, MA). Both reagent strips are read
visually, and first morning specimens are recommended.
Micral-Test reagent strips contain a gold-labeled antihuman albumin antibody-enzyme conjugate. Strips are dipped
into the urine up to a level marked on the strip and held for
5 seconds. Albumin in the urine binds to the antibody. The
bound and unbound conjugates move up the strip by wicking
TECHNICAL TIP The specific gravity of the urine specimen should be considered in evaluating urine protein because a trace protein in a dilute specimen is more
significant than in a concentrated specimen.
3920_Ch05_071-098 23/01/14 10:14 AM Page 78
78
Part Two | Urinalysis
SUMMARY 5-5
Protein Reagent Strip
Reagents
Multistix: Tetrabromophenol blue
Chemstrip: 3’,3’’,5’,5’’-tetrachlorophenol
3,4,5,6-tetrabromosulfophthalein
Sensitivity
Multistix: 15 to 30 mg/dL albumin
Chemstrip: 6 mg/dL albumin
Sources of error/interference False-positive:
Highly buffered interference alkaline
urine
Pigmented specimens, phenazopyridine
Quaternary ammonium compounds
(detergents)
Antiseptics, chlorhexidine
Loss of buffer from prolonged exposure
of the strip to the specimen reagent
High specific gravity
False-negative
Proteins other than albumin
Microalbuminuria
Correlations
Blood
with other
tests:
Nitrite
Leukocytes
Microscopic
action. Unbound conjugates are removed in a captive zone by
combining with albumin embedded in the strip. The urine
albumin–bound conjugates continue up the strip and reach an
area containing enzyme substrate. The conjugated enzyme reacts with the substrate, producing colors ranging from white
to red. The amount of color produced represents the amount
of albumin present in the urine. The color is compared with a
chart on the reagent strip bottle after 1 minute. Results range
from 0 to 10 mg/dL.
The ImmunoDip reagent strip uses an immunochromographic technique. Strips are individually packaged in specially
designed containers. The container is placed in the urine specimen for 3 minutes. A controlled amount of urine enters the
container through a vent hole. The urine encounters blue latex
particles coated with antihuman albumin antibody. Albumin
in the urine binds with the coated particles. The bound and
unbound particles continue to migrate up the strip. The migration is controlled by the size of the particles; unbound particles do not migrate as far as the bound particles. First a blue
band is formed by the unbound particles. The bound particles
continue to migrate and form a second blue band further up
the strip. The top band therefore represents the bound particles
(urine albumin) and the bottom band represents unbound
PROCEDURE 5-2
Sulfosalicylic Acid Precipitation Test
1. Add 3 mL of 3% SSA reagent to 3 mL of centrifuged
urine.
2. Mix by inversion and observe for cloudiness.
3. Grade the degree of turbidity (see table, following).
Table
Reporting SSA Turbidity
Grade
Turbidity
Negative
No increase in
turbidity
Noticeable turbidity
Distinct turbidity,
no granulation
Turbidity, granulation,
no flocculation
Turbidity, granulation,
flocculation
Clumps of protein
Trace
1+
2+
3+
4+
Protein Range
(mg/dL)
Less than 6
6–30
30–100
100–200
200–400
Greater than
400
particles. The color intensity of the bands is compared against
the manufacturer’s color chart. A darker bottom band represents less than 1.2 mg/dL, equal band colors represent
1.2 to 1.8 mg/dL, and a darker top band represents 2.0 to
8.0 mg/dL of albumin. A darker bottom band is negative, equal
band color is borderline, and a darker top band represents
positive results.
Albumin:Creatinine Ratio
The Clinitek Microalbumin reagent strips and the Multistix Pro
reagent strips (Siemens Healthcare Diagnostics, Deerfield, IN)
provide simultaneous measurement of albumin/protein and
creatinine that permits an estimation of the 24-hour microalbumin excretion.10 As discussed in Chapter 3, creatinine is
produced and excreted at a consistent rate for each individual.
Therefore, by comparing the albumin excretion to the creatinine excretion, the albumin reading can be corrected for overhydration and dehydration in a random sample. In addition to
including creatinine on the reagent strip, the albumin low-test
pad is changed to a dye-binding reaction that is more specific
for albumin than the protein error of indicators’ reaction on
strips measuring protein.
Reagent Strip Reactions
Albumin
Albumin reagent strips use the dye bis(3',3"-diiodo-4',
4"-dihydroxy-5',5"-dinitrophenyl)-3,4,5,6-tetrabromo
sulphonphthalein (DIDNTB), which has a higher sensitivity
3920_Ch05_071-098 23/01/14 10:14 AM Page 79
Chapter 5 | Chemical Examination of Urine 79
and specificity for albumin. Whereas conventional protein
reagent pads have a sensitivity of 30 mg/dL or greater and may
include proteins other than albumin, the DIDNTB strips can
measure albumin between 8 and 15 mg/dL (80 to 150 mg/L)
without inclusion of other proteins. Reaction interference by
highly buffered alkaline urine (always a concern with conventional reagent strips) is controlled by using paper treated with
bis-(heptapropylene glycol) carbonate. Addition of polymethyl
vinyl ether decreases the nonspecific binding of polyamino
acids to the albumin pad. Colors range from pale green to aqua
blue. Falsely elevated results can be caused by visibly bloody
urine, and abnormally colored urines may interfere with the
readings.2
Creatinine
The principle of the reagent strip for creatinine is based on the
pseudoperoxidase activity of copper-creatinine complexes. The
reaction follows the same principle as the reaction for blood
on the reagent strips discussed later in this chapter. Reagent
strips contain copper sulfate (CuSO4), 3,3',5,5'-tetramethylbenzidine (TMB), and diisopropyl benzene dihydroperoxide
(DBDH). Creatinine in the urine combines with the copper
sulfate to form copper-creatinine peroxidase. This reacts with
the peroxide DBDH, releasing oxygen ions that oxidize the
chromogen TMB and producing a color change from orange
through green to blue.7
CuSO4 + CRE → Cu(CRE) peroxidase
Cu(CRE) peroxidase
DBDH + TMB
(peroxidase)
(chromogen)
oxidized TMB + H2O
(orange to blue)
Results are reported as 10, 50, 100, 200, 300 mg/dL, or
0.9, 4.4, 8.8, 17.7, or 26.5 mmol/L of creatinine.
Reagent strips are unable to detect the absence of creatinine. Falsely elevated results can be caused by visibly bloody
urine and the presence of the gastric acid–reducing medication
cimetidine (Tagamet). Abnormally colored urines also may interfere with the readings.
No creatinine readings are considered abnormal, as creatinine is normally present in concentrations of 10 to 300 mg/dL.
The purpose of the creatinine measurement is to correlate the
albumin concentration to the urine concentration, producing a
semiquantitative albumin:creatinine ratio (A:C) ratio.
Albumin/Protein:Creatinine Ratio
Automated and manual methods are available for determining
the A:C ratio based on the previously discussed reactions. The
Clinitek Microalbumin reagent strips are designed for instrumental use only. Strips are read on Clinitek Urine Chemistry
Analyzers. The strips measure only albumin and creatinine and
calculate the A:C ratio. Results are displayed and printed out
for albumin, creatinine, and the A:C ratio in both conventional
and S.I. units. Abnormal results for the A:C ratio are 30 to
300 mg/g or 3.4 to 33.9 mg/mmol.10
The Siemens Multistix Pro 10 reagent strips include reagent
pads for creatinine, protein-high and protein-low (albumin),
along with pads for glucose, ketones, blood, nitrite, leukocyte
esterase, pH, bilirubin, and specific gravity. Urobilinogen is not
included on these strips. The strips can be read manually or on
automated Clinitek instruments. The protein-high reaction uses
the protein error of indicators principle and the protein-low
reaction is the previously discussed dye-binding method.
Results are reported as the protein:creatinine ratio, although the
protein-low result is used in the calculation. Results from the
Clinitek are automatically calculated. Results are reported as
normal or abnormal. A result of normal dilute indicates that the
specimen should be recollected, making sure it is a first morning specimen.
When the reagent strip is read manually, a manufacturersupplied chart is used to determine the ratio based on the results
of the protein-high, protein-low, and creatinine readings. When
using this chart, the higher of the protein-low or protein-high
result is used2 (Fig. 5–1).
Glucose
Because of its value in the detection and monitoring of diabetes
mellitus, the glucose test is the most frequently performed
chemical analysis on urine. Due to the nonspecific symptoms
associated with the onset of diabetes, it is estimated that more
than half of the cases in the world are undiagnosed. Therefore,
blood and urine glucose tests are included in all physical examinations and are often the focus of mass health screening
programs. Early diagnosis of diabetes mellitus through blood
and urine glucose tests provides a greatly improved prognosis.
Using currently available reagent strip methods for both blood
and urine glucose testing, patients can monitor themselves at
home and can detect regulatory problems prior to the development of serious complications.
Clinical Significance
Under normal circumstances, almost all the glucose filtered by
the glomerulus is actively reabsorbed in the proximal convoluted tubule; therefore, urine contains only minute amounts
of glucose. Tubular reabsorption of glucose is by active transport in response to the body’s need to maintain an adequate
concentration of glucose. Should the blood level of glucose become elevated (hyperglycemia), as occurs in diabetes mellitus,
Reported
Protein
Result
(mg/dL)
10
Negative
Recollect*
15
30
100, 300,
or 2000
Creatinine Result
(mg/dL)
50
100
200
No
300
Ab
rm
no
al
rm
al
*Specimen is too dilute to determine ratio result accurately. Repeat test on new
specimen, preferably a first-morning collection.
Figure 5–1 A protein:creatinine ratio determination chart. (Image
adapted from Bayer HealthCare LLC, Elkhart, IN.)
3920_Ch05_071-098 23/01/14 10:14 AM Page 80
80
Part Two | Urinalysis
SUMMARY 5-6
Microalbumin Testing
Immunologic Tests
Micral-Test
Principle: Enzyme immunoassay
Sensitivity: 0 to 10 mg/dL
Reagents: Gold-labeled antibody
B-galactosidase
Chlorophenol red galactoside
Interference: False-negative: Dilute urine
ImmunoDip
Principle: Immunochromographics
Sensitivity: 1.2 to 8.0 mg/dL
Reagents: Antibody-coated blue latex particles
Interference: False-negative: Dilute urine
Albumin:Creatinine Ratio
Clinitest Microalbumin Strips/Multistix-Pro
Principle: Sensitive albumin tests related to creatinine
concentration to correct for patient hydration
Reagents:
Albumin: dye bis(3’,3’’-diiodo-4’,4’’-dihydroxy-5’,5’’dinitrophenyl)-3,4,5,6-tetrabromo sulphonphtalein
(DIDNTB)
Creatinine: copper sulfate (CuSO4), 3,3’,5,5’-tetramethylbenzidine (TMB), and diisopropyl benzene
dihydroperoxide (DBDH)
Sensitivity:
Albumin: 10 to 150 mg/L
Creatinine: 10 to 300 mg/dL, 0.9 to 26.5 mmol/L
Interference:
Visibly bloody or abnormally colored urine
Creatinine: Cimetidine: False positive
Hyperglycemia that occurs during pregnancy and disappears after delivery is called gestational diabetes. The onset of
the hyperglycemia and glycosuria is normally around the sixth
month of pregnancy, although glycosuria may occur sooner.
Hormones secreted by the placenta block the action of insulin,
resulting in insulin resistance and hyperglycemia. Detection of
gestational diabetes is important to the welfare of the baby, because glucose crosses the placenta whereas insulin does not.
The baby develops high glucose levels, causing the baby’s pancreas to produce more insulin. The excess glucose presented
to the baby is stored as fat, resulting in a large baby (macrosomia) at risk for obesity and later type 2 diabetes. Women who
have gestational diabetes also are prone to developing type 2
diabetes mellitus in later years.
Hyperglycemia of nondiabetic origin is seen in a variety of
disorders and also produces glycosuria. Many of these disorders
are associated with hormonal function and include pancreatitis,
acromegaly, Cushing syndrome, hyperthyroidism, pheochromocytoma, and thyrotoxicosis. The hormones glucagon, epinephrine,
cortisol, thyroxine, and growth hormone, which are increased in
these disorders, work in opposition to insulin, thereby producing
hyperglycemia and glucosuria. Whereas a primary function of insulin is to convert glucose to glycogen for storage (glycogenesis),
these opposing hormones cause the breakdown of glycogen to
glucose (glycogenolysis), resulting in increased levels of circulating glucose. Epinephrine is also a strong inhibitor of insulin secretion and is increased when the body is subjected to severe
stress, which accounts for the glucosuria seen in conjunction with
cerebrovascular trauma and myocardial infarction.
Glycosuria occurs in the absence of hyperglycemia when
the reabsorption of glucose by the renal tubules is compromised. This is frequently referred to as “renal glycosuria” and
is seen in end-stage renal disease, cystinosis, and Fanconi syndrome. Glycosuria not associated with gestational diabetes is
occasionally seen as a result of a temporary lowering of the
renal threshold for glucose during pregnancy.
SUMMARY 5-7
the tubular transport of glucose has reached its renal threshold,
and glucose appears in the urine. The blood level at which
tubular reabsorption stops (renal threshold) for glucose is
approximately 160 to 180 mg/dL. Blood glucose levels fluctuate, and a nonfasting normal person may have glycosuria
following a meal containing a high glucose content. Therefore,
the most informative glucose results are obtained from specimens collected under controlled conditions. Fasting prior to
the collection of samples for screening tests is recommended.
For purposes of diabetes monitoring, specimens are usually
tested 2 hours after meals. A first morning specimen does not
always represent a fasting specimen because glucose from an
evening meal may remain in the bladder overnight, and patients should be advised to empty the bladder and collect the
second specimen.2
Clinical Significance of
Urine Glucose
Hyperglycemia-Associated
Renal-Associated
Diabetes mellitus
Pancreatitis
Pancreatic cancer
Acromegaly
Cushing syndrome
Hyperthyroidism
Pheochromocytoma
Central nervous system damage
Stress
Gestational diabetes
Fanconi syndrome
Advanced renal
disease
Osteomalacia
Pregnancy
3920_Ch05_071-098 23/01/14 10:14 AM Page 81
Chapter 5 | Chemical Examination of Urine 81
Reagent Strip (Glucose Oxidase) Reaction
The glucose oxidase procedure provides a specific test for glucose. Reagent strips employ the glucose oxidase testing method
by impregnating the testing area with a mixture of glucose oxidase, peroxidase, chromogen, and buffer to produce a double
sequential enzyme reaction. In the first step, glucose oxidase
catalyzes a reaction between glucose and room air (oxygen)
to produce gluconic acid and peroxide. In the second step,
peroxidase catalyzes the reaction between peroxide and chromogen to form an oxidized colored compound that is produced in direct proportion to the concentration of glucose.
1. Glucose + O2 (air)
2. H2O2 + chromogen
SUMMARY 5-8
Reagents
Sensitivity
Glucose oxidase
gluconic acid + H2O2
Peroxidase
oxidized
colored chromogen + H2O
Reagent strip manufacturers use several different chromogens, including potassium iodide (green to brown) (Multistix)
and tetramethylbenzidine (yellow to green) (Chemstrip). Urine
glucose may be reported in terms of negative, trace, 1+, 2+, 3+,
and 4+; however, the color charts also provide quantitative
measurements ranging from 100 mg/dL to 2 g/dL, or 0.1% to
2%. The American Diabetes Association recommends quantitative reporting.
Reaction Interference
Because the glucose oxidase method is specific for glucose,
false-positive reactions are not obtained from other urinary constituents, including reducing sugars that may be present. Falsepositive reactions may occur, however, if containers become
contaminated with peroxide or strong oxidizing detergents.
Substances that interfere with the enzymatic reaction or
strong reducing agents, such as ascorbic acid, that prevent oxidation of the chromogen may produce false-negative results.
To minimize interference from ascorbic acid, reagent strip manufacturers are incorporating additional chemicals into the test
pads. An example is iodate that oxidizes ascorbic acid so that it
cannot interfere with the oxidation of the chromogen. Product
literature should be carefully reviewed for current information
regarding all interfering substances. High levels of ketones also
affect glucose oxidase tests at low glucose concentrations; however, because high levels of ketones are usually accompanied
by marked glycosuria, this seldom presents a problem. High
specific gravity and low temperature may decrease the sensitivity of the test. By far the greatest source of false-negative glucose
results is the technical error of allowing specimens to remain
unpreserved at room temperature for extended periods, subjecting the glucose to bacterial degradation.
Copper Reduction Test (Clinitest)
Measurement of glucose by the copper reduction method was
one of the earliest chemical tests performed on urine. The test
relies on the ability of glucose and other substances to reduce
Interference
Correlations with
other tests
Glucose Reagent Strip
Multistix
Glucose oxidase
Peroxidase
Potassium iodide
Chemstrip
Glucose oxidase
Peroxidase
Tetramethylbenzidine
Multistix: 75 to 125 mg/dL
Chemstrip: 40 mg/dL
False-positive
Contamination by oxidizing
agents and detergents
False-negative
High levels of ascorbic acid
High levels of ketones
High specific gravity
Low temperatures
Improperly preserved specimens
Ketones
Protein
copper sulfate to cuprous oxide in the presence of alkali and
heat. A color change progressing from a negative blue (CuSO4)
through green, yellow, and orange/red (Cu2O) occurs when the
reaction takes place.
CuSO4 (cupric sulfide) + reducing substance
Heat
Alkali
Cu2O (cuprous oxide) + oxidized substance → color
(blue/green → orange/red)
The classic Benedict solution was developed in 1908 and
contained copper sulfate, sodium carbonate, and sodium citrate buffer.11 Urine was added to the solution, heat was applied, and the resulting precipitate was observed for color. A
more convenient method that employs Benedict’s principle is
the Clinitest tablet (Siemens Healthcare Diagnostics, Deerfield,
IN). The tablets contain copper sulfate, sodium carbonate,
sodium citrate, and sodium hydroxide. Upon addition of
the tablet to water and urine, heat is produced by the hydrolysis of sodium hydroxide and its reaction with sodium citrate,
and carbon dioxide is released from the sodium carbonate
to prevent room air from interfering with the reduction
reaction. Thick-walled tubes should be placed in a heatresistant rack and not held in the hand because the reaction
heat could cause a burn. At the conclusion of the effervescent
3920_Ch05_071-098 23/01/14 10:14 AM Page 82
82
Part Two | Urinalysis
reaction, the tube is gently shaken, and the color ranging from
blue to orange/red can be compared with the manufacturer’s
color chart to determine the approximate amount of reducing
substance.
Care must be taken to observe the reaction closely as it is
taking place, because at high glucose levels, a phenomenon
known as “pass through” may occur. When this happens, the
color produced passes through the orange/red stage and returns to a green-brown color, and if not observed, a high glucose level may be reported as negative. An alternate method
using two drops instead of five drops of urine can minimize
the occurrence of “pass through.” A separate color chart must
be used to interpret the reaction. This chart provides values up
to 5 g/dL, whereas the five-drop method is limited to 2 g/dL.
The sensitivity of Clinitest to glucose is reduced to a minimum of 200 mg/dL so the Clinitest cannot be used as a confirmatory test for glucose. As a nonspecific test for reducing
substances, Clinitest is subject to interference from other
reducing sugars, including galactose, lactose, fructose, maltose,
pentoses, ascorbic acid, certain drug metabolites, and antibiotics such as the cephalosporins. Therefore, Clinitest does not
provide a confirmatory test for glucose.
Clinitest tablets are very hygroscopic and should be stored
in their tightly closed packages. A strong blue color in the unused tablets suggests deterioration due to moisture accumulation, as does vigorous tablet fizzing.
Clinical Significance of Clinitest
In addition to glucose, commonly found reducing sugars include galactose, fructose, pentose, and lactose, of which galactose is the most clinically significant. Galactose in the urine of
a newborn represents an “inborn error of metabolism” in which
lack of the enzyme galactose-1-phosphate uridyl transferase
PROCEDURE 5-3
Clinitest Procedure
1. Place a thick glass test tube in a rack; add 5 drops of
urine.
2. Add 10 drops of distilled water to the urine in the
test tube.
3. Drop one Clinitest tablet into the test tube and observe
the reaction until completion (cessation of boiling).
CAUTION: The reaction mixture gets very hot. Do
not touch the bottom area of the test tube. Use thick
glass test tube only.
4. Wait 15 seconds after boiling has stopped and gently
shake the contents of the tube.
5. Compare the color of the mixture to the Clinitest
color chart and record the result in mg/dL or percent.
Observe for the possibility of the “pass-through”
phenomenon. If present, repeat the procedure using
2 drops of urine instead of 5 drops.
prevents breakdown of ingested galactose and results in failure
to thrive and other complications, including death. All states
have incorporated screening for galactosemia into their required newborn screening programs (see Chapter 8) because
early detection followed by dietary restriction can control the
condition. Depending on the laboratory population Clinitest
is often performed on pediatric specimens from patients up to
at least the age of 2 years. The appearance of other reducing
sugars is usually of minimal clinical significance, and lactose
is frequently found in the urine of nursing mothers.
Ketones
The term “ketones” represents three intermediate products of
fat metabolism, namely, acetone (2%), acetoacetic acid (20%),
and β -hydroxybutyrate (78%). Normally, measurable amounts
of ketones do not appear in the urine, because all the metabolized fat is completely broken down into carbon dioxide and
water. However, when the use of available carbohydrate as the
major source of energy becomes compromised, body stores
of fat must be metabolized to supply energy. Ketones are then
detected in urine.
Clinical Significance
Clinical reasons for increased fat metabolism include the inability to metabolize carbohydrate, as occurs in diabetes mellitus; increased loss of carbohydrate from vomiting; and
inadequate intake of carbohydrate associated with starvation
and malabsorption.
Testing for urinary ketones is most valuable in the management and monitoring of insulin-dependent (type 1) diabetes
mellitus. Ketonuria shows a deficiency in insulin, indicating
the need to regulate dosage. It is often an early indicator of insufficient insulin dosage in type 1 diabetes and in patients with
diabetes who experience medical problems in addition to diabetes. Increased accumulation of ketones in the blood leads to
electrolyte imbalance, dehydration, and, if not corrected, acidosis and eventual diabetic coma.
The use of multiple-test strips in hospital laboratories
often produces positive ketone tests unrelated to diabetes because the patient’s illness either prevents adequate intake or
absorption of carbohydrates or produces an accelerated loss,
as in the case of vomiting. Weight-loss and eating disorder clinics can use a practical application of ketonuria produced by
avoidance of carbohydrates to monitor patients. Frequent
strenuous exercise can cause overuse of available carbohydrates
and produce ketonuria.
TECHNICAL TIP Keep in mind that table sugar is sucrose,
a nonreducing sugar, and does not react with Clinitest or
glucose oxidase strips and therefore cannot be used as a
control or in preparation of a laboratory exercise for glucose testing.
3920_Ch05_071-098 23/01/14 10:14 AM Page 83
Chapter 5 | Chemical Examination of Urine 83
SUMMARY 5-9
Clinical Significance of
Urine Ketones
Diabetic acidosis
Insulin dosage monitoring
Starvation
Malabsorption/pancreatic
disorders
Strenuous exercise
Vomiting
Inborn errors of amino
acid metabolism
(see Chapter 8)
SUMMARY 5-10
Ketone Reagent Strip
Reagents:
Sodium nitroprusside
Glycine (Chemstrip)
Multistix: 5 to 10 mg/dL
acetoacetic acid
Chemstrip: 9 mg/dL acetoacetic
acid; 70 mg/dL acetone
False-positive:
Phthalein dyes
Highly pigmented red urine
Levodopa
Medications containing free
sulfhydryl groups
False-negative:
Improperly preserved specimens
Glucose
Sensitivity:
Interference:
Reagent Strip Reactions
The three ketone compounds are not present in equal amounts
in urine. Both acetone and β -hydroxybutyric acid are produced
from acetoacetic acid (Fig. 5–2). The proportions of 78%
β -hydroxybutyric acid, 20% acetoacetic acid, and 2% acetone
are relatively constant in all specimens.
Reagent strip tests use the sodium nitroprusside (nitroferricyanide) reaction to measure ketones. In this reaction, acetoacetic acid in an alkaline medium reacts with sodium
nitroprusside to produce a purple color. The test does not
measure β -hydroxybutyrate and is only slightly sensitive to
acetone when glycine is also present; however, inasmuch as
these compounds are derived from acetoacetic acid, their
presence can be assumed, and it is not necessary to perform
individual tests. Results are reported qualitatively as negative,
trace, small (1+), moderate (2+), or large (3+), or semiquantitatively as negative, trace (5 mg/dL), small (15 mg/dL), moderate (40 mg/dL), or large (80 to 160 mg/dL).
Acetoacetate (and acetone) + sodium nitroprusside
+ (glycine)
alkaline
purple color
Reaction Interference
Large amounts of levodopa and medications containing
sulfhydryl groups, including mercaptoethane sulfonate sodium
(MESNA) and captopril, may produce atypical color reactions.
Reactions with interfering substances frequently fade on standing, whereas color development from acetoacetic acid increases, resulting in false-positive results from improperly
timed readings. Falsely decreased values due to the volatilization of acetone and the breakdown of acetoacetic acid by bacteria are seen in improperly preserved specimens.
The Acetest tablet test has been used as a confirmatory test
for questionable reagent strip results; however, it was primarily
used for testing serum and other bodily fluids and dilutions
of these fluids for severe ketosis. Currently, new methods
Correlations:
measuring β -hydroxybutyrate using reagent strips have been
developed to provide automated methods for testing serum
and other body fluids. Notice in Figure 5–2 the ketone with
the highest concentration is β -hydroxybutyrate.
Acetest Tablets
Acetest (Siemens Healthcare Diagnostics Inc., Deerfield, IL)
provides sodium nitroprusside, glycine, disodium phosphate,
and lactose in tablet form. The addition of lactose gives better
color differentiation. Acetest tablets are hygroscopic; if the
specimen is not completely absorbed within 30 seconds, a new
tablet should be used. See Procedure 5–4.
Blood
Blood may be present in the urine either in the form of intact
red blood cells (hematuria) or as the product of red blood cell
destruction, hemoglobin (hemoglobinuria). As discussed in
Chapter 2, blood present in large quantities can be detected
visually; hematuria produces a cloudy red urine, and hemoglobinuria appears as a clear red specimen. Because any
amount of blood greater than five cells per microliter of urine
is considered clinically significant, visual examination cannot
be relied upon to detect the presence of blood. Microscopic
examination of the urinary sediment shows intact red blood
cells, but free hemoglobin produced either by hemolytic
OH
O
O
+2H
CH3
C
CH2
COOH
CH3
C
CH2
COOH
–CO2
CH3
C
–2H
Figure 5–2 Production of acetone and butyrate from
acetoacetic acid.
H
␤-Hydroxybutyrate
Acetoacetic acid
Acetone
CH3
3920_Ch05_071-098 23/01/14 10:15 AM Page 84
84
Part Two | Urinalysis
PROCEDURE 5-4
Acetest Procedure
1. Remove the Acetest tablet from the bottle and place
on a clean, dry piece of white paper.
2. Place 1 drop of urine on top of the tablet.
3. Wait 30 seconds.
4. Compare the tablet color with the manufacturersupplied color chart.
5. Report as negative, small, moderate, or large.
disorders or lysis of red blood cells is not detected. Therefore,
chemical tests for hemoglobin provide the most accurate
means for determining the presence of blood. Once blood has
been detected, the microscopic examination can be used to differentiate between hematuria and hemoglobinuria.
Clinical Significance
The finding of a positive reagent strip test result for blood indicates the presence of red blood cells, hemoglobin, or myoglobin. Each of these has a different clinical significance.
Hematuria
Hematuria is most closely related to disorders of renal or genitourinary origin in which bleeding is the result of trauma or
damage to the organs of these systems. Major causes of hematuria include renal calculi, glomerular diseases, tumors,
trauma, pyelonephritis, exposure to toxic chemicals, and anticoagulant therapy. The laboratory is frequently requested to
perform a urinalysis when patients presenting with severe back
and abdominal pain are suspected of having renal calculi. In
such cases, hematuria is usually of a small to moderate degree,
but its presence can be essential to the diagnosis. Hematuria
of nonpathologic significance is observed following strenuous
exercise and during menstruation.
Hemoglobinuria
Hemoglobinuria may result from the lysis of red blood cells
produced in the urinary tract, particularly in dilute, alkaline
urine. It also may result from intravascular hemolysis and the
subsequent filtering of hemoglobin through the glomerulus.
Lysis of red blood cells in the urine usually shows a mixture
of hemoglobinuria and hematuria, whereas no red blood cells
are seen in cases of intravascular hemolysis. Under normal
conditions, the formation of large hemoglobin-haptoglobin
complexes in the circulation prevents the glomerular filtration of hemoglobin. When the amount of free hemoglobin
present exceeds the haptoglobin content—as occurs in hemolytic anemias, transfusion reactions, severe burns, brown
recluse spider bites, infections, and strenuous exercise—
hemoglobin is available for glomerular filtration. Reabsorption of filtered hemoglobin also results in the appearance
of large yellow-brown granules of denatured ferritin called
hemosiderin in the renal tubular epithelial cells and in the
urine sediment.
Myoglobinuria
Myoglobin, a heme-containing protein found in muscle tissue,
not only reacts positively with the reagent strip test for blood
but also produces a clear red-brown urine. In myoglobinuria,
the presence of myoglobin rather than hemoglobin should be
suspected in patients with conditions associated with muscle
destruction (rhabdomyolysis). Examples of these conditions
include trauma, crush syndromes, prolonged coma, convulsions, muscle-wasting diseases, alcoholism, heroin abuse, and
extensive exertion. The development of rhabdomyolysis has
been found to be a side effect in certain patients taking the cholesterol-lowering statin medications.12 The heme portion of
myoglobin is toxic to the renal tubules, and high concentrations can cause acute renal failure. The massive hemoglobinuria seen in hemolytic transfusion reactions also is associated
with acute renal failure.
Reagent Strip Reactions
Chemical tests for blood use the pseudoperoxidase activity of
hemoglobin to catalyze a reaction between the heme component of both hemoglobin and myoglobin and the chromogen
tetramethylbenzidine to produce an oxidized chromogen,
which has a green-blue color.
H2O2 + chromogen
Hemoglobin
Peroxidase
oxidized chromogen + H2O
SUMMARY 5-11
Clinical Significance of a
Positive Reaction for Blood
Hematuria
Renal calculi
Glomerulonephritis
Pyelonephritis
Tumors
Trauma
Exposure to toxic
chemicals
Anticoagulants
Strenuous exercise
Hemoglobinuria
Transfusion reactions
Hemolytic anemias
Severe burns
Infections/malaria
Strenuous exercise/red
blood cell trauma
Brown recluse spider
bites
Myoglobinuria
Muscular trauma/crush
syndromes
Prolonged coma
Convulsions
Muscle-wasting diseases
Alcoholism/overdose
Drug abuse
Extensive exertion
Cholesterol-lowering statin
medications
3920_Ch05_071-098 23/01/14 10:15 AM Page 85
Chapter 5 | Chemical Examination of Urine 85
HISTORICAL NOTE
SUMMARY 5-12
Hemoglobinuria Versus Myoglobinuria
Reagents
Prior to the development of sensitive serum immunoassay
tests for myoglobin, a procedure was used to differentiate
between hemoglobin and myoglobin in the urine. A precipitation test was used to screen for the presence of myoglobin; 2.8 g of ammonium sulfate are added to 5 mL of
centrifuged urine. After mixing and allowing the specimen
to sit for 5 minutes, the urine is filtered or centrifuged,
and the supernatant is tested for a reaction for blood with
a reagent strip. The principle of this screening test is based
on the fact that the larger hemoglobin molecules are precipitated by the ammonium sulfate, and myoglobin remains in the supernatant. Therefore, when myoglobin is
present, the supernatant retains the red color and gives a
positive reagent strip test for blood. Conversely, hemoglobin produces a red precipitate and a supernatant that tests
negative for blood.
Reagent strip manufacturers incorporate peroxide, and
tetramethylbenzidine, into the blood testing area. Two color
charts are provided that correspond to the reactions that occur
with hemoglobinuria, myoglobinuria, and hematuria (RBCs).
In the presence of free hemoglobin/myoglobin, uniform color
ranging from a negative yellow through green to a strongly positive green-blue appears on the pad. In contrast, intact red
blood cells are lysed when they come in contact with the pad,
and the liberated hemoglobin produces an isolated reaction
that results in a speckled pattern on the pad. Reagent strip tests
can detect concentrations as low as five red blood cells per microliter; however, care must be taken when comparing these
figures with the actual microscopic values, because the absorbent nature of the pad attracts some of urine. The terms
trace, small, moderate, and large or trace, 1+, 2+, and 3+ are
used for reporting.
Reaction Interference
False-positive reactions due to menstrual contamination may
be seen. They also occur if strong oxidizing detergents are present in the specimen container. Vegetable peroxidase and bacterial enzymes, including an Escherichia coli peroxidase, may
also cause false-positive reactions. Therefore, sediments containing bacteria should be checked closely for the presence of
red blood cells.
Traditionally, ascorbic acid (vitamin C) has been associated
with false-negative reagent strip reactions for blood. Both Multistix and Chemstrip have modified their reagent strips to reduce this interference to very high levels (25 mg/dL) of
ascorbic acid. Multistix uses a peroxide that is less subject to
reduction by ascorbic acid, and Chemstrip overlays the reagent
pad with an iodate-impregnated mesh that oxidizes the ascorbic acid prior to its reaching the reaction pad. False-negative
reactions can result when urine with a high specific gravity
Sensitivity
Interference
Correlations with
other tests
Blood Reagent Strip
Multistix: Diisopropylbenzene
dihydroperoxide and 3,3’,5,5’tetramethylbenzidine
Chemstrip: dimethyldihydroperoxyhexane and tetramethylbenzidine
Multistix: 5 to 20 RBCs/mL, 0.015 to
0.062 mg/dL hemoglobin
Chemstrip: 5 RBCs/mL, hemoglobin
corresponding to 10 RBCs/mL
False-positive:
Strong oxidizing agents
Bacterial peroxidases
Menstrual contamination
False-negative:
High specific gravity/crenated cells
Formalin
Captopril
High concentrations of nitrite
Ascorbic acid greater than 25 mg/dL
Unmixed specimens
Protein
Microscopic
contains crenated red blood cells that do not lyse when they
come in contact with the reagent pad. Decreased reactivity may
also be seen when formalin is used as a preservative or when
the hypertension medication captopril or high concentrations
of nitrite (greater than 10 mg/dL) are present. Red blood cells
settle to the bottom of the specimen container, and failure to
mix the specimen prior to testing causes a falsely decreased
reading.
Bilirubin
The appearance of bilirubin in the urine can provide an early
indication of liver disease. It is often detected long before the
patient exhibits jaundice.
Bilirubin Production
Bilirubin, a highly pigmented yellow compound, is a degradation product of hemoglobin. Under normal conditions, the life
span of red blood cells is approximately 120 days, at which
time they are destroyed in the spleen and liver by the phagocytic cells of the reticuloendothelial system. The liberated hemoglobin is broken down into its component parts: iron,
protein, and protoporphyrin. The body reuses the iron and
protein, and the cells of the reticuloendothelial system convert
the remaining protoporphyrin to bilirubin. The bilirubin is
3920_Ch05_071-098 23/01/14 10:15 AM Page 86
86
Part Two | Urinalysis
then released into the circulation, where it binds with albumin
and is transported to the liver. At this point, the kidneys cannot
excrete the circulating bilirubin because not only is it bound
to albumin, but it is also water insoluble (unconjugated bilirubin). In the liver, bilirubin is conjugated with glucuronic acid
by the action of glucuronyl transferase to form water-soluble
bilirubin diglucuronide (conjugated bilirubin). Usually, this
conjugated bilirubin does not appear in the urine because it is
passed directly from the liver into the bile duct and on to the
intestine. In the intestine, intestinal bacteria reduce bilirubin
to urobilinogen, which is then oxidized and excreted in the
feces in the form of stercobilinogen and urobilin. Figure 5–3
illustrates bilirubin metabolism for reference with this section
and the subsequent discussion of urobilinogen.
Clinical Significance
Only conjugated bilirubin can appear in the urine when the
normal degradation cycle is disrupted by bile duct obstruction
(post-hepatic jaundice) (e.g., gallstones or cancer) or when the
integrity of the liver is damaged (hepatic jaundice), allowing
leakage of conjugated bilirubin into the circulation. Hepatitis
and cirrhosis are common examples of conditions that produce
liver damage, resulting in bilirubinuria. Not only does the detection of urinary bilirubin provide an early indication of liver
disease, but also its presence or absence can be used in determining the cause of clinical jaundice. As shown in Table 5–2,
Table 5–2
Urine Bilirubin and Urobilinogen in
Jaundice
Bile duct obstruction
Liver damage
Hemolytic disease
Urine
Bilirubin
Urine
Urobilinogen
+++
+ or –
Negative
Normal
++
+++
this determination can be even more significant when bilirubin
results are combined with urinary urobilinogen. Jaundice due
to increased destruction of red blood cells does not produce
bilirubinuria. This is because the serum bilirubin is present in
the unconjugated form and the kidneys cannot excrete it.
SUMMARY 5-13
Hepatitis
Cirrhosis
Clinical Significance of
Urine Bilirubin
Other liver disorders
Biliary obstruction (gallstones, carcinoma)
RBC
Hemoglobin
Ferritin
Heme Globin
Iron
Heme
oxygenase
Developing
erythroblasts
marrow
Amino
acid pool
Biliverdin
Bilirubin
(unconjugated)
Plasma
Unconjugated
bilirubin albumin
CO
Bilirubin
Glucuronyl transferase
+
Liver
Glucuronic
acid
Lungs
Kidney
Bilirubin diglucuronide
(conjugated)
Bile ducts
Urobilinogen
Enterohepatic circulation
Urine
Urobilinogen
Bacterial
enzymes
Stercobilinogen
Fecal urobilin
Figure 5–3 Hemoglobin degradation and production of bilirubin and urobilinogen.
3920_Ch05_071-098 23/01/14 10:15 AM Page 87
Chapter 5 | Chemical Examination of Urine 87
Reagent Strip (Diazo) Reactions
SUMMARY 5-14
Routine testing for urinary bilirubin by reagent strip uses the
diazo reaction. Bilirubin combines with 2,4-dichloroaniline diazonium salt or 2,6-dichlorobenzene-diazonium-tetrafluoroborate
in an acid medium to produce an azodye, with colors ranging
from increasing degrees of tan or pink to violet, respectively.
Qualitative results are reported as negative, small, moderate,
or large, or as negative, 1+, 2+, or 3+. Reagent strip color reactions for bilirubin are more difficult to interpret than other
reagent strip reactions and are easily influenced by other pigments present in the urine. Atypical color reactions are frequently noted on visual examination and are measured by
automated readers. Further testing should be performed on
any questionable results.
Bilirubin glucuronide + diazonium salt
Acid
Reagents
Sensitivity
Interference
azodye
Reaction Interference
As discussed previously, false-positive reactions are primarily
due to urine pigments. Of particular concern are the yelloworange urines from persons taking phenazopyridine compounds, because the thick pigment produced may be mistaken
for bilirubin on initial examination. The presence of indican
and metabolites of the medication Lodine may cause falsepositive readings.
The false-negative results caused by the testing of
specimens that are not fresh are the most frequent errors
associated with bilirubin testing. Bilirubin is an unstable
compound that is rapidly photo-oxidized to biliverdin
when exposed to light. Biliverdin does not react with diazo
tests. False-negative results also occur when hydrolysis
of bilirubin diglucuronide produces free bilirubin, because
this is less reactive in the reagent strip tests. High concentrations of ascorbic acid (greater than 25 mg/dL) and
nitrite may lower the sensitivity of the test, because they
combine with the diazonium salt and prevent its reaction
with bilirubin.
Ictotest Tablets
A confirmatory test for bilirubin is the Ictotest (Siemens
Healthcare Diagnostics Inc., Deerfield, IL). Ictotest kits consist of testing mats and tablets containing p-nitrobenzenediazonium-p-toluenesulfonate, SSA, sodium carbonate, and
boric acid. Ten drops of urine are added to the mat, which
has special properties that cause bilirubin to remain on the
surface as the urine is absorbed. Following the chemical reaction, a blue-to-purple color appears on the mat when
bilirubin is present. Colors other than blue or purple appearing on the mat are considered to be a negative result. If interference in the Ictotest is suspected, it can usually be
removed by adding water directly to the mat after the urine
has been added. Interfering substances are washed into the
mat, and only bilirubin remains on the surface.
Correlations with
other tests
Bilirubin Reagent Strip
Multistix: 2,4-dichloroaniline diazonium salt
Chemstrip: 2,6-dichlorobenzenediazonium salt
Multistix: 0.4 to 0.8 mg/dL bilirubin
Chemstrip: 0.5 mg/dL bilirubin
False-positive:
Highly pigmented urines,
phenazopyridine
Indican (intestinal disorders)
Metabolites of Lodine
False-negative:
Specimen exposure to light
Ascorbic acid greater than 25 mg/dL
High concentrations of nitrite
Urobilinogen
PROCEDURE 5-5
Ictotest Procedure
1. Place 10 drops of urine onto one square of the absorbent test mat.
2. Using forceps, remove one Ictotest reagent tablet,
recap the bottle promptly, and place the tablet in the
center of the moistened area.
3. Place 1 drop of water onto the tablet and wait 5 seconds.
4. Place a second drop of water onto the tablet so that
the water runs off the tablet onto the mat.
5. Observe the color of the mat around the tablet at the
end of 60 seconds. The presence of a blue-to-purple
color on the mat indicates that bilirubin is present. A
slight pink or red color should be ignored. Report as
positive or negative.
Urobilinogen
As shown in Figure 5–2, when conjugated bilirubin is excreted
through the bile duct into the intestine, the intestinal bacteria
convert the bilirubin to a combination of urobilinogen and stercobilinogen. Some of the urobilinogen is reabsorbed from the
intestine into the blood, recirculates to the liver, and is excreted
back into the intestine through the bile duct. The stercobilinogen
cannot be reabsorbed and remains in the intestine where it is oxidized to stercobilin. The recirculated urobilinogen that reaches
the intestine is also oxidized to urobilin. Both stercobilin and
3920_Ch05_071-098 23/01/14 10:15 AM Page 88
88
Part Two | Urinalysis
urobilin are excreted in the feces and are the pigments responsible
for the characteristic brown color of feces. Urobilinogen appears
in the urine because, as it circulates in the blood back to the liver,
it passes through the kidney and is filtered by the glomerulus.
Therefore, a small amount of urobilinogen—less than 1 mg/dL
or Ehrlich unit—is normally found in the urine.
Clinical Significance
Increased urine urobilinogen (greater than 1 mg/dL) is seen in
liver disease and hemolytic disorders. Measurement of urine
urobilinogen can be valuable in the detection of early liver disease; however, studies have shown that when urobilinogen
tests are routinely performed, 1% of the nonhospitalized population and 9% of a hospitalized population exhibit elevated
results.13 This is frequently caused by constipation.
Impairment of liver function decreases the ability of the
liver to process the urobilinogen recirculated from the intestine.
The excess urobilinogen remaining in the blood is filtered by
the kidneys and appears in the urine.
The clinical jaundice associated with hemolytic disorders results from the increased amount of circulating unconjugated
bilirubin. This unconjugated bilirubin is presented to the liver
for conjugation, resulting in a markedly increased amount of conjugated bilirubin entering the intestines. As a result, increased
urobilinogen is produced, and increased amounts of urobilinogen
are reabsorbed into the blood and circulated through the kidneys
where filtration takes place. In addition, the overworked liver
does not process the reabsorbed urobilinogen as efficiently, and
additional urobilinogen is presented for urinary excretion.
Although it cannot be determined by reagent strip, the absence of urobilinogen in the urine and feces is also diagnostically significant and represents an obstruction of the bile duct
that prevents the normal passage of bilirubin into the intestine.
An additional observation is the production of pale stools as
the result of the lack of urobilin. See Table 5–2 for an outline
of the relationship of urine bilirubin and urine urobilinogen to
the pathologic conditions associated with them.
Reagent Strip Reactions and Interference
The reagent strip reactions for urobilinogen differ between Multistix and Chemstrip much more significantly than do other reagent
strip parameters. Multistix uses Ehrlich’s aldehyde reaction, in
which urobilinogen reacts with p-dimethylaminobenzaldehyde
(Ehrlich reagent) to produce colors ranging from light to dark
pink. Results are reported as Ehrlich units (EU), which are equal
to mg/dL, ranging from normal readings of 0.2 and 1 through
abnormal readings of 2, 4, and 8. Chemstrip incorporates
SUMMARY 5-15
Clinical Significance of
Urine Urobilinogen
Early detection of liver disease
Liver disorders, hepatitis, cirrhosis, carcinoma
Hemolytic disorders
an azo-coupling (diazo) reaction using 4-methoxybenzenediazonium-tetrafluoroborate to react with urobilinogen, producing colors ranging from white to pink. This reaction is more specific for urobilinogen than the Ehrlich reaction. Results are
reported in mg/dL. Both tests detect urobilinogen that is present
in normal quantities, and color comparisons are provided for the
upper limits of normal as well as abnormal concentrations.
Reagent strip tests cannot determine the absence of urobilinogen,
which is significant in biliary obstruction.
MULTISTIX:
Urobilinogen + p-dimethylaminobenzaldehyde
(Ehrlich’s
(Ehrlich’s reagent)
reactive
substances)
Acid
red color
CHEMSTRIP:
Acid
Urobilinogen + diazonium salt
red azodye
(4-methyloxybenzene-diazonium-tetrafluoroborate)
Reaction Interference
The Ehrlich reaction on Multistix is subject to a variety of
interferences, referred to as Ehrlich-reactive compounds that
produce false-positive reactions. These include porphobilinogen, indican, p-aminosalicylic acid, sulfonamides, methyldopa,
procaine, and chlorpromazine compounds. The presence of
porphobilinogen is clinically significant; however, the reagent
strip test is not considered a reliable method to screen for its
presence. Porphobilinogen will be discussed in Chapter 8.
The sensitivity of the Ehrlich reaction increases with temperature, and testing should be performed at room temperature.
Highly pigmented urines cause atypical readings with both
brands of reagent strips. As a result of increased excretion of bile
salts, urobilinogen results are normally highest following a meal.
False-negative results occur most frequently when specimens are improperly preserved, allowing urobilinogen to be
photo-oxidized to urobilin. High concentrations of nitrite interfere with the azo-coupling reaction on Chemstrip. Falsenegative readings also are obtained with both strips when
formalin is used as a preservative.
Nitrite
Clinical Significance
The reagent strip test for nitrite provides a rapid screening test
for the presence of urinary tract infection (UTI). The test is designed to detect cases in which the need for a culture may not
TECHNICAL TIP The urobilinogen test pad on the Multistix Pro11 and Clinitek Microalbumin strips has been replaced by the protein-low test pad.
3920_Ch05_071-098 23/01/14 10:15 AM Page 89
Chapter 5 | Chemical Examination of Urine 89
SUMMARY 5-16
Reagents
Sensitivity
Interference
Correlations
with other
tests
Urobilinogen Reagent
Strip
Multistix: p-dimethylaminobenzaldehyde
Chemstrip: 4-methoxybenzenediazonium-tetrafluoroborate
Multistix: 0.2 mg/dL urobilinogen
Chemstrip: 0.4 mg/dL urobilinogen
Multistix:
False-positive:
Porphobilinogen
Indican
p-aminosalicylic acid
Sulfonamides
Methyldopa
Procaine
Chlorpromazine
Highly pigmented urine
False-negative:
Old specimens
Preservation in formalin
Chemstrip:
False-positive:
Highly pigmented urine
False-negative:
Old specimens
Preservation in formalin
High concentrations of nitrite
Bilirubin
be apparent; it is not intended to replace the urine culture as
the primary test for diagnosing and monitoring bacterial infection. Many UTIs are believed to start in the bladder as a result
of external contamination and, if untreated, progress upward
through the ureters to the tubules, renal pelvis, and kidney. The
nitrite test is valuable for detecting initial bladder infection
(cystitis), because patients are often asymptomatic or have vague
symptoms that would not lead the physician to order a urine
culture. Pyelonephritis, an inflammatory process of the kidney
and adjacent renal pelvis, is a frequent complication of untreated cystitis and can lead to renal tissue damage, impairment
of renal function, hypertension, and even septicemia. Therefore,
detection of bacteriuria through the use of the nitrite screening
test and subsequent antibiotic therapy can prevent these serious
complications. The nitrite test also can be used to evaluate the
success of antibiotic therapy and to periodically screen persons
with recurrent infections, patients with diabetes, and pregnant
women, all of whom are considered to be at high risk for UTI.
As discussed in the following section, many laboratories use the
nitrite test in combination with the leukocyte esterase test to
determine the necessity of performing urine cultures.
Reagent Strip Reactions
The chemical basis of the nitrite test is the ability of certain
bacteria to reduce nitrate, a normal constituent of urine,
to nitrite, which does not normally appear in the urine. Nitrite is detected by the Greiss reaction, in which nitrite at
an acidic pH reacts with an aromatic amine (para-arsanilic
acid or sulfanilamide) to form a diazonium compound that
then reacts with tetrahydrobenzoquinolin compounds to
produce a pink-colored azodye. To prevent false-positive
reactions in externally contaminated specimens, the sensitivity of the test is standardized to correspond with a quantitative bacterial culture criterion of 100,000 organisms per
milliliter. Although different shades of pink may be produced, the test does not measure the degree of bacteriuria,
and any shade of pink is considered to represent a clinically
significant amount of bacteria. Results are reported only as
negative or positive.
Acid
Para-arsanilic acid or sulfanilamide + NO2
diazonium salt (nitrite)
Acid
Diazonium salt + tetrahydrobenzoquinolin
pink azodye
Reaction Interference
Several major factors can influence the reliability of the nitrite
test, and tests with negative results in the presence of even
vaguely suspicious clinical symptoms should always be repeated or followed by a urine culture.
1. Bacteria that lack the enzyme reductase do not possess
the ability to reduce nitrate to nitrite. Reductase is found
in the gram-negative bacteria (Enterobacteriaceae) that
most frequently cause UTIs. Non–nitrate-reducing grampositive bacteria and yeasts, however, cause a significant
number of infections, and the nitrite test does not detect
the presence of these organisms.
SUMMARY 5-17
Clinical Significance of
Urine Nitrite
Cystitis
Pyelonephritis
Evaluation of antibiotic therapy
Monitoring of patients at high risk for urinary tract
infection
Screening of urine culture specimens
3920_Ch05_071-098 23/01/14 10:15 AM Page 90
90
Part Two | Urinalysis
2. Bacteria capable of reducing nitrate must remain in contact with the urinary nitrate long enough to produce
nitrite. Therefore, nitrite tests should be performed on
first morning specimens or specimens collected after
urine has remained in the bladder for at least 4 hours.
The correlation between positive cultures and positive
nitrite test results is significantly lower when testing is
performed on random samples.2
3. The reliability of the test depends on the presence of adequate amounts of nitrate in the urine. This is seldom a
problem in patients on a normal diet that contains green
vegetables; however, because diet usually is not controlled prior to testing, the possibility of a false-negative
result owing to lack of dietary nitrate does exist.
4. Further reduction of nitrite to nitrogen may occur when
large numbers of bacteria are present, and this causes a
false-negative reaction.
5. Other causes of false-negative results include inhibition of bacterial metabolism by the presence of antibiotics, large quantities of ascorbic acid interfering with
the diazo reaction, and decreased sensitivity in specimens with a high specific gravity. Large amounts of
ascorbic acid compete with nitrite to combine with
the diazonium salt, therefore preventing a true nitrite
measurement.
SUMMARY 5-18
Reagents
Sensitivity
Interference
Correlations
with other
tests
Nitrite Reagent Strip
Multistix: p-arsanilic acid
Tetrahydrobenzo(h)-quinolin-3-ol
Chemstrip: Sulfanilamide, hydroxytetrahydro benzoquinoline
Multistix: 0.06 to 0.1 mg/dL nitrite ion
Chemstrip: 0.05 mg/dL nitrite ion
False-negative:
Nonreductase-containing bacteria
Insufficient contact time between
bacteria and urinary nitrate
Lack of urinary nitrate
Large quantities of bacteria converting nitrite to nitrogen
Presence of antibiotics
High concentrations of ascorbic acid
High specific gravity
False-positive:
Improperly preserved specimens
Highly pigmented urine
Protein
Leukocytes
Microscopic
Leukocyte Esterase
Prior to the development of the reagent strip leukocyte
esterase (LE) test, detection of increased urinary leukocytes
required microscopic examination of the urine sediment. This
can be subject to variation depending on the method used to
prepare the sediment and the technical personnel examining
the sediment. Therefore, the chemical test for leukocytes
offers a more standardized means for the detection of leukocytes. The test is not designed to measure the concentration
of leukocytes, and the manufacturers recommend that quantitation be done by microscopic examination. An additional
advantage to the chemical LE test is that it detects the presence of leukocytes that have been lysed, particularly in dilute
alkaline urine, and would not appear in the microscopic
examination.
Clinical Significance
Normal values for leukocytes are based on the microscopic
sediment examination and vary from 0 to 2 to 0 to 5 per highpower field. Women tend to have higher numbers than men
as a result of vaginal contamination. Increased urinary leukocytes are indicators of UTI. The LE test detects the presence
of esterase in the granulocytic white blood cells (neutrophils,
eosinophils, and basophils) and monocytes, but not lymphocytes. Neutrophils are the leukocytes most frequently associated with bacterial infections. Esterases also are present in
Trichomonas and histiocytes. Lymphocytes, erythrocytes, bacteria, and renal tissue cells do not contain esterases. A positive
LE test result is most frequently accompanied by the presence
of bacteria, which, as discussed previously, may or may
not produce a positive nitrite reaction. Infections caused by
Trichomonas, Chlamydia, yeast, and inflammation of renal tissues (i.e., interstitial nephritis) produce leukocyturia without
bacteriuria.
Screening urine specimens using the LE and nitrite chemical reactions to determine the necessity of performing urine
cultures can be a cost-effective measure.14 The LE test contributes significantly more to the reliability of this practice than
does the nitrite test.
Reagent Strip Reaction
The reagent strip reaction uses the action of LE to catalyze
the hydrolysis of an acid ester embedded on the reagent pad
to produce an aromatic compound and acid. The aromatic
SUMMARY 5-19
Clinical Significance of
Urine Leukocytes
Bacterial and nonbacterial urinary tract infection
Inflammation of the urinary tract
Screening of urine culture specimens
3920_Ch05_071-098 23/01/14 10:15 AM Page 91
Chapter 5 | Chemical Examination of Urine 91
compound then combines with a diazonium salt present on
the pad to produce a purple azodye.
Indoxylcarbonic acid ester
+ diazonium salt
Leukocyte
Esterase
Acid
indoxyl + acid indoxyl
purple azodye
The LE reaction requires the longest time of all the reagent
strip reactions (2 minutes). Reactions are reported as trace, small,
moderate, and large or trace, 1+, 2+, and 3+. Trace readings may
not be significant and should be repeated on a fresh specimen.
Reaction Interference
The presence of strong oxidizing agents or formalin in the collection container causes false-positive reactions. Highly pigmented urines and the presence of the antibiotic nitrofurantoin
may obscure the color reaction.
False-negative results may occur in the presence of high
concentrations of protein (greater than 500 mg/dL), glucose
(greater than 3 g/dL), oxalic acid, and ascorbic acid. In this reaction, ascorbic acid also combines with the diazonium salt.
Crenation of leukocytes preventing release of esterases may
occur in urines with a high specific gravity. The presence of the
antibiotics gentamicin, cephalexin, cephalothin, and tetracycline decreases the sensitivity of the reaction.
SUMMARY 5-20
Reagents
Sensitivity
Interference
Correlations
with other
tests
Leukocyte Esterase
Reagent Strip
Multistix: Derivatized pyrrole amino
acid ester
Diazonium salt
Chemstrip: Indoxylcarbonic acid ester
Diazonium salt
Multistix: 5 to 15 WBC/hpf
Chemstrip: 10 to 25 WBC/hpf
False-positive:
Strong oxidizing agents
Formalin
Highly pigmented urine, nitrofurantoin
False-negative:
High concentrations of protein,
glucose, oxalic acid, ascorbic acid,
gentamicin, cephalosporins,
tetracyclines; inaccurate timing
Protein
Nitrite
Microscopic
Specific Gravity
The reagent strip test for specific gravity is included as part of
the physical examination of urine in Chapter 4 and is reviewed
here as part of the chemical examination. A summary of the
clinical significance is included in this chapter.
Reagent Strip Reaction
The reagent strip reaction is based on the change in pKa
(dissociation constant) of a polyelectrolyte in an alkaline
medium. The polyelectrolyte ionizes, releasing hydrogen ions
in proportion to the number of ions in the solution. The higher
the concentration of urine, the more hydrogen ions are released, thereby lowering the pH. Incorporation of the indicator
bromthymol blue on the reagent pad measures the change in
pH. As the specific gravity increases, the indicator changes
from blue (1.000 [alkaline]), through shades of green, to
yellow 1.030 [acid]). Readings can be made in 0.005 intervals
by careful comparison with the color chart. The specific gravity
reaction is diagrammed in Figure 5–4.
SUMMARY 5-21
Clinical Significance of
Urine Specific Gravity
Monitoring patient hydration and dehydration
Loss of renal tubular concentrating ability
Diabetes insipidus
Determination of unsatisfactory specimens due to low
concentration
COOH
COOH
COOH
COOH
COOH
COOH
POLYELECTROLYTE ON REAGENT STRIP
+
+
– –
+ –
+ –
–
+ + –
– +
– +
Ions in urine with
low specific gravity
Ions in urine with
high specific gravity
COOH
COO–H+
COOH
COOH
COO–H+
COOH
COO–H+
COO–H+
COO–H+
COO–H+
COO–H+
COO–H+
INITIAL REACTION ON REAGENT STRIP
2H+ - Bromothymol blue
6H+ - Bromothymol blue
Blue-green alkaline pH
Yellow-green acid pH
SECONDARY REACTION ON REAGENT STRIP
Figure 5–4 Diagram of reagent strip–specific gravity reaction.
3920_Ch05_071-098 23/01/14 10:16 AM Page 92
92
Part Two | Urinalysis
Reaction Interference
The reagent strip specific gravity measures only ionic solutes,
thereby eliminating the interference by the large organic molecules, such as urea and glucose, and by radiographic contrast
media and plasma expanders that are included in physical
measurements of specific gravity. This difference must be considered when comparing specific gravity results obtained by
a different method. Elevated concentrations of protein slightly
increase the readings as a result of protein anions.
Specimens with a pH of 6.5 or higher have decreased
readings caused by interference with the bromthymol blue indicator (the blue-green readings associated with an alkaline
pH correspond to a low specific gravity reading). Therefore,
manufacturers recommend adding 0.005 to specific gravity
readings when the pH is 6.5 or higher. The correction is performed by automated strip readers.
SUMMARY 5-22
Reagents
Sensitivity
Interference
Urine Specific Gravity
Reagent Strip
Multistix: Poly (methyl vinyl ether/maleic
anhydride) bromthymol blue
Chemstrip: Ethylene glycol diaminoethyl
ether tetraacetic acid, bromthymol
blue
1.000 to 1.030
False-positive: High concentrations of
protein
False-negative: Highly alkaline urines
(greater than 6.5)
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Chemstrip 10UA product Insert, Roche Diagnostics, Indianapolis,
IN, 2004.
2. Multistix Pro Reagent Strips Product Insert. Siemens Diagnostics, Tarrytown, NY 2005.
3. TechniTips, Miles Diagnostics, Elkhart, IN, October, 1992.
4. Clinical and Laboratory Standards Institute Approved Guideline GP16-A3: Urinalysis and Collection, Transportation, and
Preservation of Urine Specimens; Approved Guideline, ed 3,
CLSI, Wayne, PA, 2009.
5. College of American Pathologists, CAP Today, Confirmatory
testing. Chicago, IL. December 2011.
6. Tips from the Clinical Experts, Medical Laboratory Observer.
Web site: http://www.mlo-online.com/articles/mlo0802tips.htm
7. Pugia, MJ, and Lott, JA: New developments in urinalysis strip
tests for proteins. In Bayer Encyclopedia of Urinalysis. Bayer
Diagnostics, Elkhart, IN, 2002.
8. Bhuwnesh, A, et al: Microalbumin screening by reagent strip
predicts cardiovascular risk in hypertension. J Hypertens 14:
223–228, 1992.
9. Bianchi, S, et al: Microalbuminurea in essential hypertension.
J Nephrol 10(4):216–219, 1997.
10. Clinitek Microalbumin Reagent Strip Product Insert. Bayer
Diagnostics, Elkhart, IN, 2006.
11. Benedict, SR: A reagent for the detection of reducing sugars.
J Biol Chem 5:485–487, 1909.
12. Lane R, and Phillips, M: Rhabdomyolysis has many causes
including statins and may be fatal. Brit J Med 327:115–116,
2003.
13. Hager, CB, and Free, AH: Urine urobilinogen as a component
of routine urinalysis. Am J Med Technol 36(5):227–233, 1970.
14. Wise, KA, Sagert, LA, and Grammens, GL: Urine leukocyte esterase and nitrite tests as an aid to predict urine culture results.
Lab Med 15(3):186–187, 1984.
Study Questions
1. Leaving excess urine on the reagent strip after removing
it from the specimen will:
A. Cause run-over between reagent pads
B. Alter the color of the specimen
C. Cause reagents to leach from the pads
D. Not affect the chemical reactions
2. Failure to mix a specimen before inserting the reagent
strip will primarily affect the:
A. Glucose reading
B. Blood reading
C. Leukocyte reading
D. Both B and C
3. Testing a refrigerated specimen that has not warmed to
room temperature will adversely affect:
A. Enzymatic reactions
B. Dye-binding reactions
C. The sodium nitroprusside reaction
D. Diazo reactions
4. The reagent strip reaction that requires the longest reaction time is the:
A. Bilirubin
B. pH
C. Leukocyte esterase
D. Glucose
3920_Ch05_071-098 23/01/14 10:16 AM Page 93
Chapter 5 | Chemical Examination of Urine 93
5. Quality control of reagent strips is performed:
A. Using positive and negative controls
12. All of the following will cause false-positive protein
reagent strip values except:
B. When results are questionable
A. Microalbuminuria
C. At least once every 24 hours
B. Highly buffered alkaline urines
D. All of the above
6. All of the following are important to protect the integrity
of reagent strips except:
A. Removing the desiccant from the bottle
B. Storing in an opaque bottle
C. Storing at room temperature
D. Resealing the bottle after removing a strip
7. The principle of the reagent strip test for pH is the:
A. Protein error of indicators
B. Greiss reaction
C. Delay in removing the reagent strip from the specimen
D. Contamination by quaternary ammonium compounds
13. A patient with a 2+ protein reading in the afternoon is asked
to submit a first morning specimen. The second specimen
has a negative protein reading. This patient is:
A. Positive for orthostatic proteinuria
B. Negative for orthostatic proteinuria
C. Positive for Bence Jones protein
D. Negative for clinical proteinuria
14. Testing for microalbuminuria is valuable for early detection of kidney disease and monitoring patients with:
C. Dissociation of a polyelectrolyte
A. Hypertension
D. Double indicator reaction
B. Diabetes mellitus
8. A urine specimen with a pH of 9.0:
A. Indicates metabolic acidosis
B. Should be recollected
C. May contain calcium oxalate crystals
D. Is seen after drinking cranberry juice
9. In the laboratory, a primary consideration associated
with pH is:
A. Identifying urinary crystals
B. Monitoring vegetarian diets
C. Determining specimen acceptability
D. Both A and C
10. Indicate the source of the following proteinurias by placing a 1 for prerenal, 2 for renal, or 3 for postrenal in front
of the condition.
C. Cardiovascular disease risk
D. All of the above
15. The primary chemical on the reagent strip in the MicralTest for microalbumin binds to:
A. Protein
B. Antihuman albumin antibody
C. Conjugated enzyme
D. Galactoside
16. All of the following are true for the ImmunoDip test for
microalbumin except:
A. Unbound antibody migrates farther than bound
antibody
B. Blue latex particles are coated with antihuman
albumin antibody
A. ____Microalbuminuria
C. Bound antibody migrates further than unbound
antibody
B. ____Acute phase reactants
D. It utilizes an immunochromographic principle
C. ____Pre-eclampsia
D. ____Vaginal inflammation
17. The principle of the protein-high pad on the Multistix
Pro reagent strip is the:
E. ____Multiple myeloma
A. Diazo reaction
F. ____Orthostatic proteinuria
B. Enzymatic dye-binding reaction
G. ____Prostatitis
11. The principle of the protein error of indicators reaction
is that:
A. Protein keeps the pH of the urine constant
C. Protein error of indicators
D. Microalbumin-Micral-Test
18. Which of the following is not tested on the Multistix Pro
reagent strip?
B. Albumin accepts hydrogen ions from the indicator
A. Urobilinogen
C. The indicator accepts hydrogen ions from
albumin
B. Specific gravity
C. Creatinine
D. Albumin changes the pH of the urine
D. Protein-high
3920_Ch05_071-098 23/01/14 10:16 AM Page 94
94
Part Two | Urinalysis
19. The principle of the protein-low reagent pad on the Multistix Pro is the:
27. The most significant reagent strip test that is associated
with a positive ketone result is:
A. Binding of albumin to sulphonphthalein dye
A. Glucose
B. Immunologic binding of albumin to antibody
B. Protein
C. Reverse protein error of indicators reaction
C. pH
D. Enzymatic reaction between albumin and dye
D. Specific gravity
20. The principle of the creatinine reagent pad on microalbumin reagent strips is the:
28. The primary reagent in the reagent strip test for ketones is:
A. Glycine
A. Double indicator reaction
B. Lactose
B. Diazo reaction
C. Sodium hydroxide
C. Pseudoperoxidase reaction
D. Sodium nitroprusside
D. Reduction of a chromogen
21. The purpose of performing an albumin:creatinine ratio
is to:
A. Estimate the glomerular filtration rate
B. Correct for hydration in random specimens
C. Avoid interference for alkaline urines
D. Correct for abnormally colored urines
22. A patient with a normal blood glucose and a positive
urine glucose should be further checked for:
A. Diabetes mellitus
B. Renal disease
C. Gestational diabetes
D. Pancreatitis
23. The principle of the reagent strip tests for glucose is the:
29. Ketonuria may be caused by all of the following except:
A. Bacterial infections
B. Diabetic acidosis
C. Starvation
D. Vomiting
30. Urinalysis on a patient with severe back and abdominal
pain is frequently performed to check for:
A. Glucosuria
B. Proteinuria
C. Hematuria
D. Hemoglobinuria
31. Place the appropriate number or numbers in front of
each of the following statements. Use both numbers for
an answer if needed.
A. Peroxidase activity of glucose
1. Hemoglobinuria
B. Glucose oxidase reaction
2. Myoglobinuria
C. Double sequential enzyme reaction
A. ____ Associated with transfusion reactions
D. Dye-binding of glucose and chromogen
B. ____ Clear red urine and pale yellow plasma
24. All of the following may produce false-negative glucose
reactions except:
A. Detergent contamination
C. ____ Clear red urine and red plasma
D. ____ Associated with rhabdomyolysis
B. Ascorbic acid
E. ____ Produces hemosiderin granules in urinary
sediments
C. Unpreserved specimens
F. ____Associated with acute renal failure
D. Low urine temperature
32. The principle of the reagent strip test for blood is based
on the:
25. The primary reason for performing a Clinitest is to:
A. Check for high ascorbic acid levels
A. Binding of heme and a chromogenic dye
B. Confirm a positive reagent strip glucose
B. Peroxidase activity of heme
C. Check for newborn galactosuria
C. Reaction of peroxide and chromogen
D. Confirm a negative glucose reading
D. Diazo activity of heme
26. The three intermediate products of fat metabolism include all of the following except:
33. A speckled pattern on the blood pad of the reagent strip
indicates:
A. Acetoacetic acid
A. Hematuria
B. Ketoacetic acid
B. Hemoglobinuria
C. β -hydroxybutyric acid
C. Myoglobinuria
D. Acetone
D. All of the above
3920_Ch05_071-098 23/01/14 10:16 AM Page 95
Chapter 5 | Chemical Examination of Urine 95
34. List the following products of hemoglobin degradation
in the correct order by placing numbers 1 to 4 in the
blank.
A. ____Conjugated bilirubin
42. All of the following can cause a negative nitrite reading
except:
A. Gram-positive bacteria
B. Gram-negative bacteria
B. ____Urobilinogen and stercobilinogen
C. Random urine specimens
C. ____Urobilin
D. Heavy bacterial infections
D. ____Unconjugated bilirubin
35. The principle of the reagent strip test for bilirubin
is the:
43. A positive nitrite test and a negative leukocyte esterase
test is an indication of a:
A. Dilute random specimen
A. Diazo reaction
B. Specimen with lysed leukocytes
B. Ehrlich reaction
C. Vaginal yeast infection
C. Greiss reaction
D. Specimen older than 2 hours
D. Peroxidase reaction
36. An elevated urine bilirubin with a normal urobilinogen
is indicative of:
A. Cirrhosis of the liver
44. All of the following can be detected by the leukocyte
esterase reaction except:
A. Neutrophils
B. Eosinophils
B. Hemolytic disease
C. Lymphocytes
C. Hepatitis
D. Basophils
D. Biliary obstruction
37. The primary cause of a false-negative bilirubin reaction is:
A. Highly pigmented urine
B. Specimen contamination
C. Specimen exposure to light
D. Excess conjugated bilirubin
38. The purpose of the special mat supplied with the Ictotest
tablets is that:
A. Bilirubin remains on the surface of the mat.
B. It contains the dye needed to produce color.
C. It removes interfering substances.
D. Bilirubin is absorbed into the mat.
39. The reagent in the Multistix reaction for urobilinogen is:
45. Screening tests for urinary infection combine the leukocyte esterase test with the test for:
A. pH
B. Nitrite
C. Protein
D. Blood
46. The principle of the leukocyte esterase reagent strip test
uses a:
A. Peroxidase reaction
B. Double indicator reaction
C. Diazo reaction
D. Dye-binding technique
47. The principle of the reagent strip test for specific gravity
uses the dissociation constant of a(n):
A. A diazonium salt
A. Diazonium salt
B. Tetramethylbenzidine
B. Indicator dye
C. p-Dimethylaminobenzaldehyde
C. Polyelectrolyte
D. Hoesch reagent
D. Enzyme substrate
40. The primary problem with urobilinogen tests using
Ehrlich reagent is:
48. A specific gravity of 1.005 would produce the reagent
strip color:
A. Positive reactions with porphobilinogen
A. Blue
B. Lack of specificity
B. Green
C. Positive reactions with Ehrlich’s reactive substances
C. Yellow
D. All of the above
D. Red
41. The reagent strip test for nitrite uses the:
A. Greiss reaction
49. Reagent strip–specific gravity readings are affected by:
A. Glucose
B. Ehrlich reaction
B. Radiographic dye
C. Peroxidase reaction
C. Alkaline urine
D. Pseudoperoxidase reaction
D. All of the above
3920_Ch05_071-098 23/01/14 10:16 AM Page 96
96
Part Two | Urinalysis
Case Studies and Clinical Situations
1. A patient taken to the emergency department after an
episode of syncope has a fasting blood glucose level
of 450 mg/dL. Results of the routine urinalysis are as
follows:
COLOR: Yellow
KETONES: 2+
CLARITY: Clear
BLOOD: Negative
SP. GRAVITY: 1.015
BILIRUBIN: Negative
pH: 5.0
PROTEIN-LOW: 15 mg/dL
PROTEIN-HIGH:
30 mg/dL
NITRITE: Negative
GLUCOSE: 250 mg/dL
LEUKOCYTES: Negative
CREATININE: 200 mg/dL
a. Explain the correlation between the patient’s blood
and urine glucose results.
b. What is the most probable metabolic disorder associated with this patient?
c. Considering the patient’s condition, what is the significance of the patient’s protein to creatinine ratio
result?
d. If the patient in this study had a normal blood
glucose level and normal protein and creatinine
results, to what would the urinary glucose be
attributed?
2. Results of a urinalysis performed on a patient scheduled for gallbladder surgery are as follows:
SP. GRAVITY: 1.020
BILIRUBIN: Negative
pH: 6.0
UROBILINOGEN: 8 EU
PROTEIN: Negative
NITRITE: Negative
GLUCOSE: Negative
LEUKOCYTES: Negative
a. Would these results be indicative of hematuria or
hemoglobinuria?
b. Correlate the patient’s condition with the urobilinogen result.
c. Why is the urine bilirubin result negative in this
jaundiced patient?
d. Would this method also measure urine porphyrins?
Why or why not?
4. A female patient arrives at the outpatient clinic with
symptoms of lower back pain and urinary frequency
with a burning sensation. She is a firm believer in the
curative powers of vitamins. She has tripled her usual
dosage of vitamins in an effort to alleviate her symptoms; however, the symptoms have persisted. She is
given a sterile container and asked to collect a midstream clean-catch urine specimen. Results of this
routine urinalysis are as follows:
COLOR: Dark yellow
KETONES: Negative
CLARITY: Hazy
BLOOD: Negative
SP. GRAVITY: 1.012
BILIRUBIN: Negative
COLOR: Amber
KETONES: Negative
pH: 7.0
UROBILINOGEN: Normal
CLARITY: Hazy
BLOOD: Negative
PROTEIN: Trace
NITRITE: Negative
SP. GRAVITY: 1.022
BILIRUBIN: Moderate
GLUCOSE: Negative
LEUKOCYTES: 1+
pH: 6.0
UROBILINOGEN: Normal
Microscopic
PROTEIN: Negative
NITRITE: Negative
8 TO 12 RBC/HPF
GLUCOSE: Negative
LEUKOCYTES: Negative
40 TO 50 WBC/HPF Moderate squamous epithelial
cells
a. What discrepancies between the chemical and microscopic test results are present? State and explain
a possible reason for each discrepancy.
b. What additional chemical tests could be affected by
the patient’s vitamin dosage? Explain the principle
of the interference.
c. Discuss the urine color and specific gravity results
with regard to correlation and give a possible cause
for any discrepancy.
d. State three additional reasons not previously given
for a negative nitrite test in the presence of increased bacteria.
a. What would be observed if this specimen were
shaken?
b. Explain the correlation between the patient’s scheduled surgery and the normal urobilinogen.
c. If blood were drawn from this patient, how might
the appearance of the serum be described?
d. What special handling is needed for serum and
urine specimens from this patient?
3. Results of a urinalysis on a very anemic and jaundiced
patient are as follows:
COLOR: Red
KETONES: Negative
CLARITY: Clear
BLOOD: Large
Heavy bacteria
3920_Ch05_071-098 23/01/14 10:16 AM Page 97
Chapter 5 | Chemical Examination of Urine 97
5. Results of a urinalysis collected following practice from
a 20-year-old college athlete are as follows:
SP. GRAVITY: 1.017
BILIRUBIN: Negative
pH: 6.5
UROBILINOGEN: 0.4 EU
COLOR: Dark yellow
KETONES: Negative
PROTEIN: Trace
NITRITE: Negative
CLARITY: Hazy
BLOOD: 1+
GLUCOSE: Negative
LEUKOCYTES: Negative
SP. GRAVITY: 1.029
BILIRUBIN: Negative
pH: 6.5
UROBILINOGEN: 1 EU
a. Would hematuria be suspected in this specimen?
Why or why not?
PROTEIN: 2+
NITRITE: Negative
b. What is the most probable cause of the positive
blood reaction?
GLUCOSE: Negative
LEUKOCYTES: Negative
c. What is the source of the substance causing the positive blood reaction and the name of the condition?
The physician requests that the athlete collect another
specimen in the morning prior to classes and practice.
a. What is the purpose of the second sample?
b. What changes would you expect in the second
sample?
c. Is the proteinuria present in the first sample of prerenal, renal, or postrenal origin?
6. A construction worker is pinned under collapsed scaffolding for several hours prior to being taken to the
emergency room. His abdomen and upper legs are severely bruised, but no fractures are detected. A specimen for urinalysis obtained by catheterization has the
following results:
COLOR: Red-brown
KETONES: Negative
CLARITY: Clear
BLOOD: 4+
d. Would this patient be monitored for changes in
renal function? Why or why not?
7. Considering the correct procedures for care, technique,
and quality control for reagent strips, state a possible
cause for each of the following scenarios.
a. The urinalysis supervisor notices that an unusually
large number of reagent strips are becoming discolored before the expiration date has been reached.
b. A physician’s office is consistently reporting positive
nitrite test results with negative LE test results.
c. A student’s results for reagent strip blood and LE
are consistently lower than those of the laboratory
staff.
d. One morning the urinalysis laboratory was reporting results that were frequently questioned by
physicians.
3920_Ch05_071-098 23/01/14 10:16 AM Page 98
3920_Ch06_099-146 23/01/14 10:18 AM Page 99
CHAPTER
6
Microscopic Examination
of Urine
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
6-1 List the physical and chemical parameters included
in macroscopic urine screening, and state their
significance.
6-2 Discuss the advantages of commercial systems over
the glass-slide method for sediment examination.
6-3 Describe the recommended methods for standardizing
specimen preparation and volume; centrifugation;
sediment preparation, volume, and examination; and
reporting results.
6-4 State the purpose of Sternheimer-Malbin, acetic acid,
toluidine blue, Sudan III, Gram, Hansel, and Prussian
blue stains in the examination of urine sediment.
6-5 Identify specimens that should be referred for cytodiagnostic testing.
6-6 Describe the basic principles of bright-field, phasecontrast, polarizing, dark-field, fluorescence, and
interference-contrast microscopy and their relationship to sediment examination.
6-9 Discuss the significance of white blood cells (WBCs)
in urine sediment.
6-10 Name, describe, and give the origin and significance
of the three types of epithelial cells found in urine
sediment.
6-11 Discuss the significance of oval fat bodies.
6-12 Describe the process of cast formation.
6-13 Describe and discuss the significance of hyaline, RBC,
WBC, bacterial, epithelial cell, granular, waxy, fatty,
and broad casts.
6-14 List and identify the normal crystals found in acidic
urine.
6-15 List and identify the normal crystals found in alkaline
urine.
6-16 Describe and state the significance of cystine, cholesterol, leucine, tyrosine, bilirubin, sulfonamide, radiographic dye, and ampicillin crystals.
6-7 Differentiate between normal and abnormal sediment
constituents.
6-17 Differentiate between actual sediment constituents and
artifacts.
6-8 Discuss the significance of red blood cells (RBCs) in
urine sediment.
6-18 Correlate physical and chemical urinalysis results with
microscopic observations and recognize discrepancies.
KEY TERMS
Birefringent
Dark-field microscopy
Phase-contrast microscopy
Bright-field microscopy
Fluorescence microscopy
Polarizing microscopy
Casts
Interference-contrast microscopy
Resolution
Cylindruria
Köhler illumination
Uromodulin
3920_Ch06_099-146 23/01/14 10:18 AM Page 100
100
Part Two | Urinalysis
The third part of routine urinalysis, after physical and chemical
examination, is the microscopic examination of the urinary
sediment. Its purpose is to detect and to identify insoluble materials present in the urine. The blood, kidney, lower genitourinary tract, and external contamination all contribute formed
elements to the urine. These include red blood cells (RBCs),
white blood cells (WBCs), epithelial cells, casts, bacteria, yeast,
parasites, mucus, spermatozoa, crystals, and artifacts. Because
some of these components are of no clinical significance and
others are considered normal unless they are present in increased amounts, examination of the urinary sediment must
include both identification and quantitation of the elements
present. Microscopic analysis is subject to several procedural
variations, including the methods by which the sediment is
prepared, the volume of sediment actually examined, the
methods and equipment used to obtain visualization, and
the manner in which the results are reported. Protocols have
been developed to increase the standardization and costeffectiveness of microscopic urinalysis, and they are discussed
in this chapter.
Macroscopic Screening
To enhance the cost-effectiveness of urinalysis, many laboratories have developed protocols whereby microscopic examination of the urine sediment is performed only on specimens
meeting specified criteria. Abnormalities in the physical and
chemical portions of the urinalysis play a primary role in the
decision to perform a microscopic analysis, thus the use of
the term “macroscopic screening.”
Parameters considered significant vary among laboratories
but usually include color, clarity, blood, protein, nitrite, leukocyte esterase, and possibly glucose. Laboratory-designated
criteria can also be programed into automated instruments.
Table 6–1 illustrates the significance of these parameters. Percentages of abnormal specimens that would go undetected
using these parameters differ significantly among studies. 1,2
Table 6–1
Macroscopic Screening and Microscopic
Correlations
Screening Test
Significance
Color
Clarity
Blood
Hematuria versus hemoglobinuria/
myoglobinuria
Confirm pathologic or nonpathologic cause of turbidity
RBCs, RBC casts
Casts, cells
Bacteria, WBCs
WBCs, WBC casts, bacteria
Yeast
Blood
Protein
Nitrite
Leukocyte esterase
Glucose
The patient population must also be considered when developing protocols for macroscopic screening. Populations that have
come under consideration include pregnant women, as well as
pediatric, geriatric, diabetic, immunocompromised, and renal
patients. The Clinical and Laboratory Standards Institute
(CLSI) recommends that microscopic examination be performed when requested by a physician, when a laboratoryspecified patient population is being tested, or when any abnormal physical or chemical result is obtained.3
Specimen Preparation
Specimens should be examined while fresh or adequately preserved. Formed elements—primarily RBCs, WBCs, and hyaline casts—disintegrate rapidly, particularly in dilute alkaline
urine. Refrigeration may cause precipitation of amorphous
urates and phosphates and other nonpathologic crystals that
can obscure other elements in the urine sediment. Warming
the specimen to 37°C prior to centrifuging may dissolve some
of these crystals.
The midstream clean-catch specimen minimizes external
contamination of the sediment. As with the physical and chemical analyses, dilute random specimens may cause false-negative
readings.
Care must be taken to thoroughly mix the specimen prior
to decanting a portion into a centrifuge tube.
Specimen Volume
A standard amount of urine, usually between 10 and 15 mL, is
centrifuged in a conical tube. This provides an adequate volume
from which to obtain a representative sample of the elements
present in the specimen. A 12-mL volume is frequently used
because multiparameter reagent strips are easily immersed in
this volume, and capped centrifuge tubes are often calibrated
to this volume.
If obtaining a 12-mL specimen is not possible, as with pediatric patients, the volume of the specimen used should be
noted on the report form. This allows the physician to correct
the results, if indicated. Some laboratories choose to make this
correction prior to reporting. For example, if 6 mL of urine is
centrifuged, the results are multiplied by 2.
Centrifugation
The speed of the centrifuge and the length of time the specimen is centrifuged should be consistent. Centrifugation for
5 minutes at a relative centrifugal force (RCF) of 400 produces
an optimum amount of sediment with the least chance of damaging the elements. To correct for differences in the diameter
of centrifuge heads, RCF rather than revolutions per minute
(RPM) is used. The RPM value shown on the centrifuge
tachometer can be converted to RCF using nomograms available in many laboratory manuals or by using the formula:
RCF = 1.118 × 10–5 × radius in centimeters × RPM2
Centrifugation calibration should be routinely performed.
Use of the braking mechanism to slow the centrifuge causes
3920_Ch06_099-146 23/01/14 10:18 AM Page 101
Chapter 6 | Microscopic Examination of Urine 101
disruption of the sediment prior to decantation and should not
be used.
To prevent biohazardous aerosols, all specimens must be
centrifuged in capped tubes.
Sediment Preparation
A uniform amount of urine and sediment should remain in the
tube after decantation. Volumes of 0.5 and 1.0 mL are frequently used. The volume of urine centrifuged divided by the
sediment volume equals the concentration factor, which in the
preceding examples are 24 and 12, respectively. The sediment
concentration factor relates to the probability of detecting elements present in low quantities and is used when quantitating
the number of elements present per milliliter.
To maintain a uniform sediment concentration factor,
urine should be aspirated off rather than poured off, unless
otherwise specified by the commercial system in use. Some
systems provide pipettes for this purpose. The pipettes are also
used for sediment resuspension and transferring specimens to
the slide.
The sediment must be thoroughly resuspended by gentle
agitation. This can be performed using a commercial-system
pipette or by repeatedly tapping the tip of the tube with the
finger. Vigorous agitation should be avoided, as it may disrupt
some cellular elements. Thorough resuspension is essential
to provide equal distribution of elements in the microscopic
examination fields.
Urisystem (ThermoFisher Scientific, Waltham, MA), Count-10
(V-Tech, Inc., Pomona, CA), Quick-Prep Urinalysis System
(Globe Scientific, Paramus, NJ), CenSlide 2000 Urinalysis
System (International Remote Imaging Systems, Norwood,
MA), and R/S Workstations 1000, 2000, 2003 (DioSys,
Waterbury, CA). The systems provide a variety of options
including capped, calibrated centrifuge tubes; decanting
pipettes to control sediment volume; and slides that control
the amount of sediment examined, produce a consistent
monolayer of sediment for examination, and provide calibrated grids for more consistent quantitation.
The Cen-Slide and R/S Workstations do not require manual loading of the centrifuged specimen onto a slide and are
considered closed systems that minimize exposure to the specimen. Cen-Slide provides a specially designed tube that permits
direct reading of the urine sediment. The R/S Workstations
consist of a glass flow cell into which urine sediment is
pumped, microscopically examined, and then flushed from the
system.
Examining the Sediment
The volume of sediment placed on the microscope slide
should be consistent for each specimen. When using the
conventional glass-slide method, the recommended volume is 20 µ L (0.02 mL) covered by a 22 × 22 mm glass
cover slip. Allowing the specimen to flow outside of the
cover slip may result in the loss of heavier elements such
as casts.
Commercial systems control the volume of sediment examined by providing slides with chambers capable of containing a specified volume. Care must be taken to ensure the
chambers are completely filled. Product literature supplies the
chamber volume, size of the viewing area, and approximate
number of low-power and high-power viewing areas, based
on the area of the field of view using a standard microscope.
This information, together with the sediment concentration
factor, is necessary to quantitate cellular elements per milliliter
of urine.
Microscopic examination should be performed in a consistent
manner and include observation of a minimum of 10 fields
under both low (10×) and high (40×) power. The slide is first
examined under low power to detect casts and to ascertain the
general composition of the sediment. When elements such as
casts that require identification are encountered, the setting is
changed to high power.
If the conventional glass-slide method is being used, casts
have a tendency to locate near the edges of the cover slip;
therefore, low-power scanning of the cover-slip perimeter is
recommended. This does not occur when using standardized
commercial systems.
When the sediment is examined unstained, many sediment constituents have a refractive index similar to urine.
Therefore, it is essential that sediments be examined under
reduced light when using bright-field microscopy.
Initial focusing can be difficult with a fluid specimen, and
care must be taken to ensure that the examination is being performed in the correct plane. Often an epithelial cell will be
present to provide a point of reference. Focusing on artifacts
should be avoided, because they are often larger than the regular sediment elements and cause the microscopist to examine
objects in the wrong plane. Continuous focusing with the fine
adjustment aids in obtaining a complete representation of the
sediment constituents.
Commercial Systems
Reporting the Microscopic Examination
The conventional method of placing a drop of centrifuged
urine on a glass slide, adding a cover slip, and examining microscopically has been substantially improved through the
use of commercial slide systems. 4 The CLSI recommends
their use together with standardization of all phases of the
methodology, including the conventional method, as discussed in the following sections. Systems currently available
include KOVA (Hycor Biomedical, Inc., Garden Grove, CA),
The terminology and methods of reporting may differ slightly
among laboratories but must be consistent within a particular
laboratory system. Routinely, casts are reported as the average
number per low-power field (lpf) following examination of
10 fields, and RBCs and WBCs, as the average number per
10 high-power fields (hpf). Epithelial cells, crystals, and other
elements are frequently reported in semiquantitative terms
such as, rare, few, moderate, and many, or as 1+, 2+, 3+, and 4+,
Volume of Sediment Examined
3920_Ch06_099-146 23/01/14 10:18 AM Page 102
102
Part Two | Urinalysis
following laboratory format as to lpf or hpf use. Laboratories
must also determine their particular reference values based on
the sediment concentration factor in use. For example, Urisystem, with a concentration factor of 30, states a reference value
for WBCs of zero to eight per hpf, as opposed to the conventional value of zero to five per hpf used with a concentration
factor of 12.
Converting the average number of elements per lpf or hpf
to the number per milliliter provides standardization among
the various techniques in use. Steps include the following:
EXAMPLE
1. Calculating the area of an lpf or hpf for the microscope in
use using the manufacturer-supplied field of view
diameter and the formula πr2 = area.
Diameter of hpf = 0.35 mm
3.14 × 0.1752 = 0.096 mm2
2. Calculating the maximum number of lpfs or hpfs in the
viewing area.
Area under a 22 mm × 22 mm cover slip = 484 mm2
484
= 5040 hpfs
.096
3. Calculating the number of hpfs per milliliter of urine
tested using the concentration factor and the volume
of sediment examined.
5040
5040
=
= 21,000 hpf/mL of urine
0.02 mL × 12
.24
4. Calculating the number of formed elements per milliliter
of urine by multiplying the number of hpfs per milliliter
by the average number of formed elements per field.
HISTORICAL NOTE
Addis Count
The first procedure to standardize the quantitation of
formed elements in the urine microscopic analysis was developed by Addis in 1926. The Addis count, as it is called,
used a hemocytometer to count the number of RBCs,
WBCs, casts, and epithelial cells present in a 12-hour
specimen. Normal values have a wide range and are approximately 0 to 500,000 RBCs, 0 to 1,800,000 WBCs
and epithelial cells, and 0 to 5000 hyaline casts. 5 The
Addis count, which was used primarily to monitor the
course of diagnosed cases of renal disease, has been replaced by various standardized commercial systems for
the preparation, examination, and quantitation of formed
elements in nontimed specimens.
Table 6–2
Microscopic
Elements
RBCs
WBCs
Epithelial
cells
Casts
Bacteria
Routine Urinalysis Correlations
Physical
Chemical
Exceptions
Turbidity
Red color
Turbidity
+ Blood
+ Protein
+ Protein
+ Nitrite
+ LE
Number
Hemolysis
Number
Lysis
Turbidity
Turbidity
+ Protein
↑ pH
Turbidity
+ Nitrite
+ Leukocytes
pH
Color
+ Bilirubin
4 WBC/hpf × 21,000 = 84,000 WBC/mL
Provided the same microscope and volume of sediment
examined are used, the number of lpfs and hpfs per milliliter
of urine remains the same, thereby simplifying the calculation.
Laboratories should evaluate the advantages and disadvantages of adding an additional calculation step to the microscopic examination. The CLSI states that all decisions with
regard to reporting of the microscopic should be based on the
needs of the individual laboratory. Procedures should be completely documented and followed by all personnel.3
Correlating Results
Microscopic results should be correlated with the physical and
chemical findings to ensure the accuracy of the report. Specimens in which the results do not correlate must be rechecked
for both technical and clerical errors. Table 6–2 shows some
of the more common correlations in the urinalysis; however,
the amount of formed elements or chemicals must also be
Crystals
Number
Number
Number
and type
Number
and type
considered, as must the possibility of interference with chemical tests and the age of the specimen.
Sediment Examination
Techniques
Many factors can influence the appearance of the urinary sediment, including cells and casts in various stages of development and degeneration, distortion of cells and crystals by the
chemical content of the specimen, the presence of inclusions
in cells and casts, and contamination by artifacts. Therefore,
3920_Ch06_099-146 23/01/14 10:18 AM Page 103
Chapter 6 | Microscopic Examination of Urine 103
identification can sometimes be difficult even for experienced
laboratory personnel. Identification can be enhanced through
the use of sediment stains (Table 6–3) and different types of
microscopy.
Sediment Stains
Staining increases the overall visibility of sediment elements
being examined using bright-field microscopy by changing
their refractive index. As mentioned, elements such as hyaline
casts have a refractive index very similar to that of urine. Staining also imparts identifying characteristics to cellular structures, such as the nuclei, cytoplasm, and inclusions.
The most frequently used stain in urinalysis is the
Sternheimer-Malbin stain, which consists of crystal violet and
Table 6–3
safranin O.6 The stain is available commercially under a variety
of names, including Sedi-Stain (Becton, Dickinson, Parsippany,
NJ) and KOVA stain (Hycor Biomedical, Inc., Garden Grove,
CA). Commercial brands contain stabilizing chemicals to prevent the precipitation that occurred with the original stain. The
dye is absorbed well by WBCs, epithelial cells, and casts, providing clearer delineation of structure and contrasting colors
of the nucleus and cytoplasm. Table 6–4 provides an example
of the staining reactions as shown in the product literature.
A 0.5% solution of toluidine blue, a metachromatic stain,
provides enhancement of nuclear detail. It can be useful in the
differentiation between WBCs and renal tubular epithelial cells
and is also used in the examination of cells from other body
fluids.
Urine Sediment Stain Characteristics
Stain
Action
Function
Sternheimer-Malbin
Identifies WBCs, epithelial cells, and casts
Toluidine blue
Delineates structure and contrasting colors of
the nucleus and cytoplasm
Enhances nuclear detail
2% acetic acid
Lyses RBCs and enhances nuclei of WBCs
Lipid stains: Oil Red
O and Sudan III
Gram stain
Stain triglycerides and neutral fats orange-red
Do not stain cholesterol
Differentiates gram-positive and gram-negative
bacteria
Methylene blue and eosin Y stains eosinophilic
granules
Stains structures containing iron
Hansel stain
Prussian blue stain
Table 6–4
Differentiates WBCs and renal tubular
epithelial (RTE) cells
Distinguishes RBCs from WBCs, yeast, oil
droplets, and crystals
Identify free fat droplets and lipid-containing
cells and casts
Identifies bacterial casts
Identifies urinary eosinophils
Identifies yellow-brown granules of hemosiderin in cells and casts
Expected Staining Reactions of Urine Sediment Constituents
Elements in Urinary
Sediment
Usual Distinguishing Color
of Stained Elements
RBCs
Neutral—pink to purple
Acid—pink (unstained)
Alkaline—purple
Nuclei
Cytoplasm
WBCs (dark-staining cells)
Purple
Purple granules
Glitter cells (SternheimerMalbin positive cells)
Renal tubular epithelial
cells
Bladder tubular epithelial
cells
Colorless or light blue
Pale blue or
gray
Light shade of
blue-purple
Light purple
Dark shade of blue-purple
Blue-purple
Comments
Some glitter cells exhibit
brownian movement
Continued
3920_Ch06_099-146 23/01/14 10:18 AM Page 104
104
Part Two | Urinalysis
Table 6–4
Expected Staining Reactions of Urine Sediment Constituents—cont’d
Elements in Urinary
Sediment
Usual Distinguishing Color
of Stained Elements
Squamous epithelial cells
Dark shade of orange-purple
Comments
Light purple or
blue
Inclusions and Matrix
Hyaline casts
Pale pink or pale purple
Coarse granular inclusion
casts
Finely granular inclusion
casts
Dark purple granules in purple
matrix
Fine dark purple granules in
pale pink or pale purple
matrix
Pale pink or pale purple
Waxy casts
Fat inclusion casts
Fat globules unstained in a
pink matrix
Red cell inclusion casts
Pink to orange-red
Blood (hemoglobin) casts
Bacteria
Trichomonas vaginalis
Orange-red
Motile: do not stain
Nonmotile: stain purple
Light blue-green
Mucus
Background
Pale pink or pale blue
Pale pink or pale purple
Very uniform color; slightly
darker than mucous threads
Darker than hyaline casts, but
of a pale even color; distinct
broken ends
Rare; presence is confirmed if
examination under polarized light indicates double
refraction
Intact cells can be seen in
matrix
No intact cells
Motile organisms are not
impaired
Motility is unimpaired in fresh
specimens when recommended volumes of stain
are used; immobile organisms also identifiable
From Product Profile: Sedi-Stain. Clay Adams, Division of Becton, Dickinson & Company, Parsippany, NJ, 1974, with permission.
Nuclear detail is also enhanced by the addition of 2%
acetic acid to the sediment. This method cannot be used for
initial sediment analysis because RBCs are lysed by the acetic
acid (see Fig. 6–18 later in this chapter).
Lipid Stains
The passage of lipids (triglycerides, neutral fats, and cholesterol)
across the glomerular membrane results in the appearance of
free fat droplets and lipid-containing cells and casts in the urinary sediment. The lipid stains, Oil Red O and Sudan III, and
polarizing microscopy can be used to confirm the presence of
these elements. Triglycerides and neutral fats stain orange-red
in the presence of stain, whereas cholesterol does not stain but
is capable of polarization. The three lipids are usually present
concurrently in the sediment, thereby permitting use of either
staining or polarization for their confirmation.
Gram Stain
The Gram stain is used primarily in the microbiology section
for the differentiation between gram-positive (blue) and gramnegative (red) bacteria. Its role in routine urinalysis is limited
to the identification of bacterial casts, which can easily be confused with granular casts. To perform Gram staining, a dried,
heat-fixed preparation of the urine sediment must be used.
Hansel Stain
Polynuclear WBCs seen in the urinary sediment are almost always neutrophils associated with microbial infection. However,
in cases of a drug-induced allergic reaction producing inflammation of the renal interstitium, eosinophils are present in the
sediment. The preferred stain for urinary eosinophils is Hansel
stain, consisting of methylene blue and eosin Y (Lide Labs, Inc.,
3920_Ch06_099-146 23/01/14 10:18 AM Page 105
Chapter 6 | Microscopic Examination of Urine 105
Florissant, MO); however, Wright’s stain can also be used.
Staining is performed on a dried smear of the centrifuged specimen or a cytocentrifuged preparation of the sediment.
Table 6–5
Technique
Function
Prussian Blue Stain
Bright-field
microscopy
Phase-contrast
microscopy
Used for routine urinalysis
As discussed in Chapter 5, after episodes of hemoglobinuria,
yellow-brown granules may be seen in renal tubular epithelial
cells and casts or free-floating in the urine sediment. To confirm that these granules are hemosiderin, the Prussian blue
stain for iron is used and stains the hemosiderin granules a
blue color.
Cytodiagnostic Urine Testing
Although it is not a part of the routine examination of the
urine sediment, the preparation of permanent slides using cytocentrifugation followed by staining with Papanicolaou stain
provides an additional method for detecting and monitoring
renal disease. Cytodiagnostic urine testing is frequently performed independently of routine urinalysis for detection of
malignancies of the lower urinary tract. A voided first morning
specimen is recommended for testing, which is performed by
the cytology laboratory. Cytodiagnostic urine testing also provides more definitive information about renal tubular changes
associated with transplant rejection; viral, fungal, and parasitic
infections; cellular inclusions; pathologic casts; and inflammatory conditions. The urinalysis laboratory should refer
specimens with unusual cellular findings to the pathologist
for further examination.
Microscopy
Microscopic examination of urine is best performed when the
laboratorian is knowledgeable about the types of microscopes
available, their primary characteristics, and the proper use and
maintenance of these microscopes.
Bright-field microscopy is the most common type of microscopy performed in the urinalysis laboratory. Other types
of microscopy that are useful for examining the urine sediment
are phase contrast, polarizing, dark field, fluorescence, and interference contrast (Table 6–5). The type of microscopy used
depends on the specimen type, the refractive index of the object, and the ability to image unstained living cells. All microscopes are designed to magnify small objects to such a degree
that the details of their structure can be analyzed. Basically,
they do this by employing a variety of lenses and light sources
as described in the following section.
The Microscope
Essentially all types of microscopes contain a lens system, illumination system, and a body consisting of a base, body tube,
and nosepiece (Fig. 6–1). Primary components of the lens system are the oculars, the objectives, and the coarse- and fineadjustment knobs. The illumination system contains the light
source, condenser, and field and iris diaphragms. Objects to
be examined are placed on a platform, referred to as the mechanical stage. The compound bright-field microscope is used
primarily in the urinalysis laboratory and consists of a two-lens
Urinalysis Microscopic Techniques
Polarizing
microscopy
Dark-field
microscopy
Fluorescence
microscopy
Interferencecontrast
Enhances visualization of elements
with low refractive indices, such
as hyaline casts, mixed cellular
casts, mucous threads, and
Trichomonas
Aids in identification of cholesterol
in oval fat bodies, fatty casts, and
crystals
Aids in identification of Treponema
pallidum
Allows visualization of naturally
fluorescent microorganisms or
those stained by a fluorescent
dye including labeled antigens
and antibodies
Produces a three-dimensional
microscopy image and layerby-layer imaging of a specimen
system combined with a light source. The first lens system is
located in the objective and is adjusted to be near the specimen. The second lens system, the ocular lens, is located in the
eyepiece. The path of light passes through the specimen up to
the eyepiece.
The oculars or eyepieces of the microscope are located at
the top of the body tube. Clinical laboratory microscopes are
binocular, allowing the examination to be performed using
both eyes to provide more complete visualization. For optimal
viewing conditions, the oculars can be adjusted horizontally
to adapt to differences in interpupillary distance between
operators. A diopter adjustment knob on the oculars can be
rotated to compensate for variations in vision between the operators’ eyes. The oculars are designed to further magnify the
object that has been enhanced by the objectives for viewing.
Laboratory microscopes normally contain oculars capable of
increasing the magnification 10 times (10×). The field of view
is determined by the eyepiece and is the diameter of the circle
of view when looking through the oculars. The field of view
varies with the field number engraved on the eyepiece and the
magnification of the objective. The higher the magnification,
the smaller the field of view will be. In urinalysis microscopy,
sediment constituents are reported as the number per microscopic field (number per hpf or lpf).
Objectives are contained in the revolving nosepiece
located above the mechanical stage. Objectives are adjusted to
be near the specimen and perform the initial magnification of
the object on the mechanical stage. The image then passes to
the oculars for further resolution (ability to visualize fine details). Resolution is the ability of the lens to distinguish two
3920_Ch06_099-146 23/01/14 10:18 AM Page 106
106
Part Two | Urinalysis
Interpupillary
distance control
Body
Condenser
focus knob
Ocular
Nosepiece
Objective
Course
adjustment
knob
Fine
adjustment
knob
Mechanical stage
adjustment knobs
Condenser aperture
diaphragm control ring
Condenser
Centering screw
Field diaphragm
control ring
Rheostat
Figure 6–1 Parts of the binocular
microscope.
PROCEDURE 6-1
Care of the Microscope
1. Carry microscope with two hands, supporting the
base with one hand.
2. Always hold the microscope in a vertical position.
3. Clean optical surfaces only with a good quality lens
tissue and commercial lens cleaner.
4. Do not use the 10× and 40× objectives with oil.
5. Clean the oil immersion lens after use.
6. Always remove slides with the low-power objective
raised.
7. Store the microscope with the low-power objective in
position and the stage centered.
small objects that are a specific distance apart. Resolving power
is best when the distance between the two objects is small. It
is dependent on the wavelength of light and the numerical
aperture of the lens. The shorter the wavelength of light, the
greater the resolving power of the microscope will be. Routinely used objectives in the clinical laboratory have magnifications of 10× (low power, dry), 40× (high power, dry), and
100× (oil immersion). The objectives used for examination of
urine sediment are 10× and 40×. The final magnification of an
object is the product of the objective magnification times the
ocular magnification. Using a 10× ocular and a 10× objective
provides a total magnification of 100× and in urinalysis is the
lpf observation. The 10× ocular and the 40× objective provide
a magnification of 400× for hpf observations.
Objectives are inscribed with information that describes
their characteristics and includes the type of objective (plan
used for bright field, ph for phase contrast), magnification, numerical aperture, microscope tube length, and cover-slip thickness to be used. The numerical aperture number represents the
refractive index of the material between the slide and the outer
lens (air or oil) and the angle of the light passing through it.
The higher the numerical aperture, the better the light-gathering
capability of the lens will be, thus yielding greater resolving
power. The length of the objectives attached to the nosepiece
varies with magnification (length increases from 10× to 100×
magnification), thereby changing the distance between the lens
and the slide when they are rotated. The higher the numerical
aperture, the closer the lens is to the object. Most microscopes
are designed to be parfocal, indicating that they require only
minimum adjustment when switching among objectives.
The distance between the slide and the objective is controlled by the coarse- and fine-focusing knobs located on the
body tube. Initial focusing is performed using the coarse knob
that moves the mechanical stage noticeably up and down until
the object comes into view. This is followed by adjustment
using the fine-focusing knob to sharpen the image. When
using a parfocal microscope, only the fine knob should be used
for adjustment when changing magnifications.
Illumination for the modern microscope is provided by a
light source located in the base of the microscope. The light
source is equipped with a rheostat to regulate the intensity of
the light. Filters may also be placed on the light source to vary
the illumination and wavelengths of the emitted light. A field
diaphragm contained in the light source controls the diameter
of the light beam reaching the slide and is adjusted for optimal
illumination. A condenser located below the stage then focuses
the light on the specimen and controls the light for uniform
3920_Ch06_099-146 23/01/14 10:18 AM Page 107
Chapter 6 | Microscopic Examination of Urine 107
illumination. The normal position of the condenser is almost
completely up with the front lens of the condenser near the
slide but not touching it. The condenser adjustment (focus)
knob moves the condenser up and down to focus light on the
object. An aperture diaphragm in the condenser controls the
amount of light and the angle of light rays that pass to the specimen and lens, which affects resolution, contrast, and depth of
the field of image. By adjusting the aperture diaphragm to 75%
of the numerical aperture of the objective, maximum resolution
is achieved. The aperture diaphragm should not be used to reduce light intensity because it decreases resolution. The microscope lamp rheostat is used for this adjustment.
Köhler Illumination
Two adjustments to the condenser—centering and Köhler
illumination—provide optimal viewing of the illuminated field.
They should be performed whenever an objective is changed.
To center the condenser and obtain Köhler illumination, take
the following steps:
• Place a slide on the stage and focus the object using the
low-power objective with the condenser raised.
• Close the field diaphragm.
• Lower the condenser until the edges of the field diaphragm are sharply focused.
• Center the image of the field diaphragm with the condenser centering screws as shown in Figure 6–2, part A.
• Open the field diaphragm until its image is at the edge of
the field.
• Remove an eyepiece and look down through the eyepiece
tube.
• Adjust the aperture diaphragm until approximately 75%
of the field is visible (see Fig. 6–2, part B).
• Replace the eyepiece.
Additional focusing of the object should be performed using
the adjustment knobs and the rheostat on the light source.
Routine preventive maintenance procedures on the microscope ensure good optical performance. The microscope
Field of
view
A
Field of view
Illuminated
zone
Field of
view
Illuminated
zone
B
Figure 6–2 Centering the condenser and Köhler illumination.
should always be covered when not in use to protect it from
dust. If any optical surface becomes coated with dust, it should
be carefully removed with a camel-hair brush. Optical surfaces
should be cleaned with lens paper. Clean any contaminated
lens immediately with a commercial lens cleaner. An oil immersion lens must be wiped free of oil and cleaned after each
use. Fingerprints and oil smears impair the sharpness of an
image. An annual professional cleaning for the microscope is
recommended. Light sources are replaced as necessary.
Types of Microscopy
Bright-Field Microscopy
Bright-field microscopy, in which objects appear dark against
a light background, is most frequently used in the clinical laboratory. This technique employs the basic microscope previously described with a light source emitting light in the visible
wavelength range.
Use of bright-field microscopy for the examination of
urine sediment can present problems when the amount of light
reaching the specimen is not properly controlled. Sediment
constituents with a low refractive index will be overlooked
when subjected to light of high intensity. Therefore, sediments
must be examined using decreased light controlled by adjusting the rheostat on the light source, not by lowering the condenser. Staining of the sediment also increases the visualization
of these elements when using bright-field microscopy.
Phase-Contrast Microscopy
As light rays pass through an object, they are slowed in comparison to the rays passing through air (media), thereby decreasing the intensity of the light and producing contrast. This
is called phase difference and is affected by the thickness of the
object, refractive index, and other light-absorbance properties.
The best contrast is obtained when the light that does not pass
through the specimen is shifted one quarter of a wavelength
and compared with the phase difference of the specimen.
Phase-contrast microscopy provides this contrast.
Phase-contrast microscopy is accomplished by adaptation
of a bright-field microscope with a phase-contrast objective
lens and a matching condenser. Two phase rings that appear
as “targets” are placed in the condenser and the objective. One
phase ring is placed in the condenser or below it, permitting
light to only pass through the central clear circular area. A second phase-shifting ring with a central circular area that retards
the light by one quarter wavelength is placed in the objective.
Phase rings must match, so it is important to check that the
objective and condenser mode are the same. The diameter of
the rings varies with the magnification. The image has the best
contrast when the background is darkest. Phase-contrast rings
must be adjusted to have maximum contrast. The two rings
are adjusted to make them concentric. Adjustment steps are as
follows:7
• Focus the microscope in bright-field with a specimen
slide.
• Select a low-power phase condenser ring.
3920_Ch06_099-146 23/01/14 10:18 AM Page 108
108
Part Two | Urinalysis
• Select the corresponding ring objective.
• Remove an ocular, insert the adjustment telescope, and
look through the telescope.
• Observe the dark and light rings (annuli).
• With the adjusting screw on the telescope, center the
light annulus (condenser) over the dark annulus
(objective) (Fig. 6–3).
• Replace the ocular.
Light passes to the specimen through the clear circle in
the phase ring in the condenser, forming a halo of light around
the specimen. The diffracted light then enters the central circle
of the phase-shifting ring, and all other light is moved one
quarter of a wavelength out of phase. The variations of contrast
in the specimen image due to the various refractive indexes in
the object are observed as the light rays merge together, enhancing visualization and detail. Phase-contrast microscopy is
particularly advantageous for identifying low refractive hyaline
casts or mixed cellular casts and mucous threads.
Polarizing Microscopy
The use of polarized light aids in the identification of crystals
and lipids. Both substances have the ability to rotate the path
of the unidirectional polarized light beam to produce characteristic colors in crystals and Maltese cross formation in lipids.
These elements seen under polarized light microscopy are
birefringent, a property indicating that the element can refract light in two dimensions at 90 degrees to each other.
The halogen quartz lamp in the microscope produces light
rays of many different waves. Each wave has a distinct direction
and a vibration perpendicular to its direction. Normal or
unpolarized light vibrates in equal intensity in all directions.
Polarized light vibrates in the same plane or direction. As the
light passes through a birefringent substance, it splits into two
beams, one beam rotated 90 degrees to the other. Isotropic substances such as blood cells do not have this refractive property,
and the light passes through unchanged. A substance that
rotates the plane of polarized light 90 degrees in a clockwise
direction is said to have positive birefringence. In contrast, a
Condenser
ring
substance that rotates the plane in a counterclockwise direction
has negative birefringence.
Polarized light is obtained by using two polarizing filters.
The light emerging from one filter vibrates in one plane, and a
second filter placed at a 90-degree angle blocks all incoming
light, except that rotated by the birefringent substance. The
filters are in opposite directions called a “crossed configuration.” Between cross-polarizing filters, birefringent crystals are
visible in characteristic patterns (Fig. 6–4).
Bright-field microscopes can be adapted for polarizing
microscopy. Two polarizing filters must be installed in a
crossed configuration. The first filter, the polarizing filter, is
placed in the condenser filter holder; the second filter, the
analyzer, is placed in the head between the objectives and the
ocular. The polarizing filter is rotated to allow light vibrating
in one direction only to reach the object. If the object does not
have birefringent properties, no light will reach the analyzer
filter and the object will appear black. Refracted rays from a
birefringent object will reach the analyzer, causing the object
to appear white or colored against the black background. An
additional filter called a red compensated polarizing filter can
be added to the microscope. This filter divides the light entering the microscope into slow and fast vibrations. Crystals
can be more easily identified by aligning them with the slow
vibration and observing the blue or yellow color they produce
(see Chapter 11).
Polarizing microscopy is used in urinalysis to confirm the
identification of fat droplets, oval fat bodies, and fatty casts that
produce a characteristic Maltese cross pattern. Birefringent uric
acid crystals can be distinguished from cystine crystals, monohydrate calcium oxalate crystals from nonpolarizing RBCs, and
calcium phosphate crystals differentiated from nonpolarizing
bacteria by their polarizing characteristics.
Interference-Contrast Microscopy
Interference-contrast microscopy provides a three-dimensional
image showing very fine structural detail by splitting the light ray
so that the beams pass through different areas of the specimen.
The light interference produced by the varied depths of the specimen is compared, and a three-dimensional image is visualized.
The advantage of interference-contrast microscopy is that an
object appears bright against a dark background but without
the diffraction halo associated with phase-contrast microscopy.
More extensive modifications to the bright-field microscope are
Birefringent
specimen
Phase objective
ring
Alignment
Centering phase microscope rings
Figure 6–3 Phase-contrast ring adjustment.
Rotated
wave
Light
source
Polarizing
filter
Wave separated Polarizing filter
90° by specimen 90° orientation
Figure 6–4 Diagram of polarized light.
3920_Ch06_099-146 23/01/14 10:18 AM Page 109
Chapter 6 | Microscopic Examination of Urine 109
required to perform this technique. Therefore, it is not routinely
used in the urinalysis laboratory.
Two types of interference-contrast microscopy are available:
modulation contrast (Hoffman) and differential-interference
contrast (Nomarski). Bright-field microscopes can be adapted
for both methods. In the modulation-contrast microscope, a
split aperture is placed below the condenser, a polarizer is
placed below the split aperture, and an amplitude filter is placed
in back of each objective. The modulator has three zones of
light transmission: a dark zone that transmits 1% of light, a
gray zone that transmits 15% of light, and a clear zone that
transmits 100% of light. The polarized light rays pass through
a split aperture to the various areas of the specimen and to the
modulator where they are converted into the variations of light
intensity to produce a three-dimensional image. The differential
interference-contrast microscope uses prisms. A polarizing filter
to output plane-polarized light is placed between the light
source and the condenser. A two-layered Nomarski-modified
Wollaston prism that separates individual rays of light into ray
pairs is required. The lower Wollaston prism is built into the
condenser of the microscope. The upper prism is placed between the objective and the eyepiece and recombines the rays.
Above the top Wollaston prism, another polarizing filter is
placed that causes wave interference to occur and produce
the three-dimensional image (Fig. 6–5).8 These two types of
microscopy provide layer-by-layer imaging of a specimen and
enhanced detail for specimens with either a low or high refractive index.
black. As the light rays pass through the specimen at oblique
angles, the light scatters, diffracts, or reflects off the specimen
and is captured by the objective lens. The specimen appears
light against the black background or dark-field (Fig. 6–6).
Fluorescence Microscopy
Fluorescence microscopy is a rapidly expanding technique
used in the medical field today. It is used to detect bacteria and
viruses within cells and tissues through a technique called immunofluorescence. Fluorescence is the property by which
some atoms absorb light at a particular wavelength and subsequently emit light of a longer wavelength, termed fluorescence
lifetime. The practical application in the laboratory is that it
allows the visualization of naturally fluorescent substances or
those that have been stained with a fluorochrome or fluorophore (fluorescent dyes) to produce an image. The specimen
is illuminated with a light of a specific wavelength. Fluorescent
substances absorb the energy and emit a longer wavelength of
light that is visualized with the use of special filters, called the
excitation filter and the emission filter. The excitation filter selects the excitation wavelength of light from a light source. The
emission filter selects a specific wavelength of emitted light
from the specimen to become visible. The filters are chosen to
match the excitation and emission wavelengths of the fluorophore used to label the specimen. A dichroic mirror reflects
the excitation light to the specimen and transmits the emitted
light to the emission filter, which is collected with the objective
Dark-Field Microscopy
Ocular lens
Dark-field microscopy is a technique used in the clinical laboratory to enhance visualization of specimens that cannot be
seen easily viewed with a bright-field microscope. It is often
used for unstained specimens, and, in particular, to identify
the spirochete Treponema pallidum.
A bright-field microscope is easily adapted for dark-field
microscopy by replacing the condenser with a dark-field condenser that contains an opaque disk. The disk blocks the light
from directly entering the objective, and the field of view is
Analyzer
Recombined rays
Objective lens
Three-dimensional
image
Upper Wollaston
prism
Specimen
Back focal plane
of objective lens
Objective
Specimen
Condenser
lens
Condenser lens
Split rays
Condenser focal
plane
Dark-field stop
Lower Wollaston
prism
Polarizer
Figure 6–5 Differential interference-contrast (Nomarski) microscopy.
Light rays
Figure 6–6 Dark-field microscopy.
3920_Ch06_099-146 23/01/14 10:18 AM Page 110
110
Part Two | Urinalysis
and imaged by the detector (Fig. 6–7). The fluorescent substance can be observed in the fluorescent microscope as a
bright object against a dark background with high contrast
when ultraviolet light source is used. Powerful light sources
are required and are usually either mercury or xenon arc
lamps.9
Urine Sediment Constituents
The normal urine sediment may contain a variety of formed
elements. Even the appearance of small numbers of the usually
pathologically significant RBCs, WBCs, and casts can be normal. Likewise, many routine urine specimens contain nothing
more than a rare epithelial cell or mucous strand. Students
often have difficulty adjusting to this, because in the classroom
setting, urine sediments containing abnormalities and multiple
elements are usually stressed. They must learn to trust their
observations after looking at the recommended number of
fields. Cellular elements are also easily distorted by the widely
varying concentrations, pH, and presence of metabolites in
urine, making identification more difficult.
Actual normal numerical values are not clearly defined. As
discussed previously, urine sediment preparation methods
determine the actual concentration of the sediment and, therefore, the number of elements that may be present in a microscopic field. Commonly listed values include zero to two or
three RBCs per hpf, zero to five to eight WBCs per hpf, and
zero to two hyaline casts per lpf. Even these figures must be
taken in context with other factors, such as recent stress and
exercise, menstrual contamination, and the presence of other
urine sediment constituents. To put this in better perspective,
the urine sediment constituents are now discussed individually
with reference to the accompanying figures.
Red Blood Cells
In the urine, RBCs appear as smooth, non-nucleated, biconcave
disks measuring approximately 7 mm in diameter (Fig. 6–8).
They must be identified using high-power (40×) objective
(×400 magnification). RBCs are routinely reported as the average number seen in 10 hpfs.
In concentrated (hypersthenuric) urine, the cells shrink
due to loss of water and may appear crenated or irregularly
shaped (Fig. 6–9). In dilute (hyposthenuria) urine, the cells
absorb water, swell, and lyse rapidly, releasing their hemoglobin and leaving only the cell membrane. These large empty
cells are called ghost cells and can be easily missed if specimens are not examined under reduced light.
Of all the urine sediment elements, RBCs are the most difficult for students to recognize. The reasons for this include
RBCs’ lack of characteristic structures, variations in size, and
close resemblance to other urine sediment constituents. RBCs
are frequently confused with yeast cells, oil droplets, and air
bubbles. Yeast cells usually exhibit budding (Fig. 6–10). Oil
droplets and air bubbles are highly refractile when the fine
Ocular
Barrier filter
Objective
Figure 6–8 Normal RBCs (×400).
Specimen
Condenser
Mercury lamp
Incoming
light waves
Collector
Excitation filter
Deflecting mirror
Ultraviolet light
Visible light
Figure 6–7 Fluorescent microscopy.
Figure 6–9 Microcytic and crenated RBCs (×100).
3920_Ch06_099-146 23/01/14 10:18 AM Page 111
Chapter 6 | Microscopic Examination of Urine 111
Figure 6–10 Yeast. The presence of budding forms aid in distinguishing from RBCs (×400).
adjustment is focused up and down (Fig. 6–11); they may also
appear in a different plane than other sediment constituents
(Fig. 6–12). The rough appearance of crenated RBCs may resemble the granules seen in WBCs, but they are much smaller
than WBCs. Should the identification continue to be doubtful,
adding acetic acid to a portion of the sediment will lyse the
Figure 6–11 KOVA-stained squamous epithelial cells and oil droplets
(×400). Notice how the oil droplet (arrow) resembles an RBC.
Figure 6–12 Air bubble. Notice no formed elements are in focus
(×100).
RBCs, leaving the yeast, oil droplets, and WBCs intact. Supravital staining may also be helpful.
Studies have focused on the morphology of urinary RBCs
as an aid in determining the site of renal bleeding. RBCs that
vary in size, have cellular protrusions, or are fragmented are
termed dysmorphic (Fig. 6–13) and have been associated primarily with glomerular bleeding. The number and appearance
of the dysmorphic cells must also be considered, because abnormal urine concentration affects RBC appearance, and small
numbers of dysmorphic cells are found with nonglomerular
hematuria.10,11 Dysmorphic RBCs also have been demonstrated
after strenuous exercise, indicating a glomerular origin of this
phenomenon.12 The dysmorphic cell most closely associated
with glomerular bleeding appears to be the acanthocyte with
multiple protrusions, which may be difficult to observe under
bright-field microscopy.13,14 Further analysis of sediments containing dysmorphic RBCs using Wright’s stained preparations
shows the cells to be hypochromic and better delineates the
presence of cellular blebs and protrusions.
Clinical Significance
The presence of RBCs in the urine is associated with damage
to the glomerular membrane or vascular injury within the
genitourinary tract. The number of cells present is indicative
of the extent of the damage or injury. Patient histories often
mention the presence of macroscopic versus microscopic
hematuria.
When macroscopic hematuria is present, the urine appears cloudy with a red to brown color. Microscopic analysis
may be reported in terms of greater than 100 per hpf or as
specified by laboratory protocol. Macroscopic hematuria is frequently associated with advanced glomerular damage but is
also seen with damage to the vascular integrity of the urinary
tract caused by trauma, acute infection or inflammation, and
coagulation disorders.
The observation of microscopic hematuria can be critical
to the early diagnosis of glomerular disorders and malignancy
of the urinary tract and to confirm the presence of renal calculi.
The presence of not only RBCs but also hyaline, granular, and
Figure 6–13 Dysmorphic RBCs (×400). Notice the smaller size and
fragmentation.
3920_Ch06_099-146 23/01/14 10:18 AM Page 112
112
Part Two | Urinalysis
RBC casts may be seen following strenuous exercise. These
abnormalities are nonpathologic and disappear after rest.15 The
possibility of menstrual contamination must also be considered
in specimens from female patients.
As discussed previously, the presence or absence of RBCs
in the urine sediment cannot always be correlated with specimen color or a positive chemical test result for blood. The presence of hemoglobin that has been filtered by the glomerulus
produces a red urine with a positive chemical test result for
blood in the absence of microscopic hematuria. Likewise, a
specimen appearing macroscopically normal may contain
a small but pathologically significant number of RBCs when
examined microscopically.
White Blood Cells
WBCs are larger than RBCs, measuring an average of about
12 mm in diameter (Fig. 6–14).
The predominant WBC found in the urine sediment is
the neutrophil. Neutrophils are much easier to identify than
RBCs because they contain granules and multilobed nuclei
(Fig. 6–15 A and B). However, they are still identified using
high-power microscopy and are also reported as the average
SUMMARY 6-1
A
Microscopic RBCs
Appearance:
Sources of
identification
error:
Reporting:
Complete urinalysis
correlations:
Non-nucleated biconcave disks
Crenated in hypertonic urine
Ghost cells in hypotonic urine
Dysmorphic with glomerular
membrane damage
Yeast cells
Oil droplets
Air bubbles
Average number per 10 hpfs
Color
Reagent strip blood reaction
B
Figure 6–15 WBCs. A. One segmented and one nonsegmented WBC
(×400). B. Notice the multilobed nucleoli (×400).
number seen in 10 hpfs. Neutrophils lyse rapidly in dilute
alkaline urine and begin to lose nuclear detail.
Neutrophils exposed to hypotonic urine absorb water and
swell. Brownian movement of the granules within these larger
cells produces a sparkling appearance, and they are referred to
as “glitter cells.” When stained with Sternheimer-Malbin stain,
these large cells stain light blue as opposed to the violet color
usually seen with neutrophils. Glitter cells are of no pathologic
significance (Fig. 6–16).
Eosinophils
Figure 6–14 RBCs and one WBC (×400). Notice the larger size and
granules in the WBC.
The presence of urinary eosinophils is primarily associated
with drug-induced interstitial nephritis. Small numbers of
eosinophils may be seen with urinary tract infection (UTI) and
renal transplant rejection. Evaluation of a concentrated, stained
urine sediment is required for performing a urinary eosinophil
test. Urine sediment may be concentrated by routine centrifugation alone or with cytocentrifugation. The preferred
eosinophil stain is Hansel (Fig. 6–17); however, Wright’s stain
can also be used. The percentage of eosinophils in 100 to 500
cells is determined. Eosinophils are not normally seen in the
urine; therefore, the finding of more than 1% eosinophils is
considered significant.16
3920_Ch06_099-146 23/01/14 10:18 AM Page 113
Chapter 6 | Microscopic Examination of Urine 113
Figure 6–18 WBCs with acetic acid nuclear enhancement. Notice the
ameboid shape in some of the WBCs.
Figure 6–16 Glitter cells (×400). Observe the very noticeable
granules.
Usually, fewer than five leukocytes per hpf are found in
normal urine; however, higher numbers may be present in
urine from females. Although leukocytes, like RBCs, may enter
the urine through glomerular or capillary trauma, they are also
capable of ameboid migration through the tissues to sites of
infection or inflammation. An increase in urinary WBCs is
called pyuria and indicates the presence of an infection or
inflammation in the genitourinary system. Bacterial infections,
including pyelonephritis, cystitis, prostatitis, and urethritis,
are frequent causes of pyuria. However, pyuria is also present
in nonbacterial disorders, such as glomerulonephritis, lupus
erythematosus, interstitial nephritis, and tumors. Reporting
the presence of bacteria in specimens containing leukocytes
is important.
Epithelial Cells
Figure 6–17 Hansel-stained eosinophils (×400).
It is not unusual to find epithelial cells in the urine, because
they are derived from the linings of the genitourinary system.
Unless they are present in large numbers or in abnormal forms,
Mononuclear Cells
Lymphocytes, monocytes, macrophages, and histiocytes may
be present in small numbers and are usually not identified in
the wet preparation urine microscopic analysis. Because lymphocytes are the smallest WBCs, they may resemble RBCs.
They may be seen in increased numbers in the early stages of
renal transplant rejection. Monocytes, macrophages, and histiocytes are large cells and may appear vacuolated or contain
inclusions. Specimens containing an increased amount of
mononuclear cells that cannot be identified as epithelial cells
should be referred for cytodiagnostic urine testing.
The primary concern in the identification of WBCs is the
differentiation of mononuclear cells and disintegrating neutrophils from round renal tubular epithelial (RTE) cells. RTE
cells are usually larger than WBCs with an eccentrically
located nucleus. WBCs in the process of ameboid motion
may be difficult to distinguish from epithelial cells because
of their irregular shape. Supravital staining or the addition of
acetic acid can be used to enhance nuclear detail (Fig. 6–18),
if necessary.
SUMMARY 6-2
Appearance:
Sources of
identification
error:
Microscopic WBCs
Larger than RBCs
Granulated, multilobed neutrophils
Glitter cells in hypotonic urine
Mononuclear cells with abundant
cytoplasm
Renal tubular epithelial cells
Reporting:
Average number per 10 hpfs
Complete
urinalysis
correlations:
Leukocyte esterase
Nitrite
Specific gravity
pH
3920_Ch06_099-146 23/01/14 10:18 AM Page 114
114
Part Two | Urinalysis
they represent normal sloughing of old cells. Three types of
epithelial cells are seen in urine: squamous, transitional
(urothelial), and renal tubular (Fig. 6–19). They are classified
according to their site of origin within the genitourinary
system.
Squamous Epithelial Cells
Squamous cells are the largest cells found in the urine sediment.
They contain abundant, irregular cytoplasm and a prominent
nucleus about the size of an RBC (Fig. 6–20 A and B). They
are often the first structures observed when the urine sediment
is examined under low-power magnification. Usually at least a
few squamous epithelial cells are present in the urine sediment
and can serve as a good reference for focusing of the microscope. After examination of the appropriate number of fields,
squamous epithelial cells are commonly reported in terms of
rare, few, moderate, or many. They are reported in terms of
low-power or high-power magnification based on laboratory
protocol.
Difficulty identifying squamous cells is rare. However, they
may occasionally appear folded, possibly resembling a cast,
and will begin to disintegrate in urine that is not fresh. In urine
sediments containing large amounts of squamous cells, clumps
of cells may make it more difficult to enumerate smaller pathologic elements, such as RBCs and WBCs, and they should be
carefully examined (Figs. 6–21, 6–22, and 6–23).
Squamous epithelial cells originate from the linings of the
vagina and female urethra and the lower portion of the male
urethra. They represent normal cellular sloughing and have no
pathologic significance. Increased amounts are more frequently
seen in urine from female patients. Specimens collected using
the midstream clean-catch technique contain less squamous
cell contamination.
A variation of the squamous epithelial cell is the clue cell,
which does have pathologic significance. Clue cells are indicative of vaginal infection by the bacterium Gardnerella vaginalis.
They appear as squamous epithelial cells covered with the
Gardnerella coccobacillus. To be considered a clue cell, the
bacteria should cover most of the cell surface and extend
A
B
Figure 6–20 A. Squamous epithelial cells identifiable under low
power (×100). B. KOVA-stained squamous epithelial cells (×400). Compare the size of the nucleus with the RBCs in Figure 6-8.
RBC
Transitional
WBC
Squamous
RTE
Figure 6–19 Sediment-containing squamous, caudate transitional,
and RTE cells (×400).
Figure 6–21 Phenazopyridine-stained sediment showing squamous
epithelial cells and phenazopyridine crystals formed following refrigeration (×400).
beyond the edges of the cell. This gives the cell a granular, irregular appearance. Routine testing for clue cells is performed
by examining a vaginal wet preparation for the presence of the
characteristic cells (see Chapter 15). However, small numbers
of clue cells may be present in the urinary sediment. Microscopists should remain alert for their presence, as urinalysis
may be the first test performed on the patient.
3920_Ch06_099-146 23/01/14 10:18 AM Page 115
Chapter 6 | Microscopic Examination of Urine 115
Figure 6–22 Clump of squamous epithelial cells (×400).
Figure 6–23 Clump of squamous epithelial cells with folded forms
(×400).
Figure 6–24 Transitional epithelial cells.
Figure 6–25 KOVA-stained spherical transitional epithelial cells
(×400).
Transitional Epithelial (Urothelial) Cells
Transitional epithelial cells are smaller than squamous cells and
appear in several forms, including spherical, polyhedral, and
caudate (Figs. 6–24, 6–25, and 6–26). These differences are
caused by the ability of transitional epithelial cells to absorb
large amounts of water. Cells in direct contact with the urine
absorb water, becoming spherical in form and much larger
than the polyhedral and caudate cells. All forms have distinct,
centrally located nuclei. Transitional cells are identified and
enumerated using high-power magnification. Like squamous
cells, they are usually reported as rare, few, moderate, or many
following laboratory protocol.
Spherical forms of transitional epithelial cells are sometimes difficult to distinguish from RTE cells. The presence of a
centrally located rather than eccentrically placed nucleus, and
supravital staining, can aid in the differentiation.
Transitional epithelial cells originate from the lining of the
renal pelvis, calyces, ureters, and bladder, and from the upper
portion of the male urethra. They are usually present in small
Figure 6–26 Caudate transitional epithelial cells (×400).
numbers in normal urine, representing normal cellular sloughing. Increased numbers of transitional cells seen singly, in pairs,
or in clumps (syncytia) are present following invasive urologic
procedures such as catheterization and are of no clinical significance (Fig. 6–27). An increase in transitional cells exhibiting
3920_Ch06_099-146 23/01/14 10:18 AM Page 116
116
Part Two | Urinalysis
Figure 6–27 Syncytia of transitional epithelial cells from catheterized
specimen (×400).
Figure 6–29 RTE cells. Oval distal convoluted tubule cells. Notice the
eccentrically placed nuclei (×400).
abnormal morphology such as vacuoles and irregular nuclei
may be indicative of malignancy or viral infection. In such cases,
the specimen should be referred to the pathologist.
spherical and polyhedral transitional cells (Fig. 6–30). Because RTE cells are often present as a result of tissue destruction (necrosis), the nucleus is not easily visible in unstained
sediment.
Cells from the collecting duct that appear in groups of
three or more are called renal fragments. They are frequently
seen as large sheets of cells. PCT and DCT cells are not seen in
large sheets of cells (Fig. 6–31).
Renal Tubular Epithelial Cells
RTE cells vary in size and shape depending on the area of the
renal tubules from which they originate. The cells from the proximal convoluted tubule (PCT) are larger than other RTE cells.
They tend to have a rectangular shape and are referred to as
columnar or convoluted cells. The cytoplasm is coarsely granular,
and the RTE cells often resemble casts. They should be closely
examined for the presence of a nucleus, as a nucleus would
not be present in a cast. Notice the nucleus and granules in
Figure 6–28. This is a PCT. This is fine cell that has absorbed fat
globules and could easily be mistaken for a granular or fatty cast.
Cells from the distal convoluted tubule (DCT) are smaller
than those from the PCT and are round or oval. They can be
mistaken for WBCs and spherical transitional epithelial cells.
Observation of the eccentrically placed round nucleus aids in
differentiating them from spherical transitional cells (Fig. 6–29).
Collecting duct RTE cells are cuboidal and are never
round. Along with the eccentrically placed nucleus, the presence of at least one straight edge differentiates them from
Figure 6–30 RTE cells, cuboidal from the collecting duct (×400).
N
Figure 6–28 RTE cell. Columnar proximal convoluted tubule cell with
granules and attached fat globules (×400). N, nucleus.
Figure 6–31 Fragment of RTE cells from the collecting duct under
phase microscopy (×400).
3920_Ch06_099-146 23/01/14 10:18 AM Page 117
Chapter 6 | Microscopic Examination of Urine 117
RTE cells must be identified and enumerated using
high-power magnification. Depending on laboratory protocol, they may be reported as rare, few, moderate, or many,
or as the actual number per high-power field. Classification
of RTE cells as to site of origin is not considered a part of
the routine sediment analysis and often requires special
staining techniques. The presence of more than two RTE
cells per high-power field indicates tubular injury, and
such specimens should be referred for cytologic urine
testing.17
Clinical Significance
RTE cells are the most clinically significant of the epithelial
cells. The presence of increased amounts is indicative of necrosis of the renal tubules, with the possibility of affecting overall
renal function.
Conditions producing tubular necrosis include exposure
to heavy metals, drug-induced toxicity, hemoglobin and myoglobin toxicity, viral infections (hepatitis B), pyelonephritis, allergic reactions, malignant infiltrations, salicylate poisoning,
and acute allogenic transplant rejection. RTE cells may also be
seen as secondary effects of glomerular disorders. Renal fragments are an indication of severe tubular injury with basement
membrane disruption. Single cuboidal cells are particularly noticeable in cases of salicylate poisoning.
Because one of the functions of RTE cells is reabsorption
of the glomerular filtrate, it is not unusual for them to contain
substances from the filtrate. RTE cells absorb bilirubin present
in the filtrate as the result of liver damage, such as occurs with
viral hepatitis, and appear a deep yellow color. As discussed
in Chapter 5, hemoglobin present in the filtrate is absorbed
by the RTE cells and converted to hemosiderin. Therefore, following episodes of hemoglobinuria (transfusion reactions,
paroxysmal nocturnal hemoglobinuria, etc.), the RTE cells
may contain the characteristic yellow-brown hemosiderin
granules. The granules may also be seen free-floating in the
urine sediment. Confirmation of the presence of hemosiderin
is performed by staining the urine sediment with Prussian
blue. The iron-containing hemosiderin granules stain blue
(Fig. 6–32).
Oval Fat Bodies
RTE cells absorb lipids that are present in the glomerular filtrate. They then appear highly refractile, and the nucleus may
be more difficult to observe. These lipid-containing RTE cells
are called oval fat bodies (Fig. 6–33). They are usually seen in
conjunction with free-floating fat droplets.
Identification of oval fat bodies is confirmed by staining
the urine sediment with Sudan III or Oil Red O fat stains and
examining the sediment using polarized microscopy. The
droplets are composed of triglycerides, neutral fats, and cholesterol. Fat stains stain triglycerides and neutral fats, producing orange-red droplets (Fig. 6–34). Examination of the urine
sediment using polarized light results in the appearance of
characteristic Maltese cross formations in droplets containing
cholesterol (Fig. 6–35). Urine sediments negative for fat after
staining should still be checked using polarized light in case
only cholesterol is present. Likewise, staining should be performed on urine sediments negative under polarized light.
Oval fat bodies are reported as the average number per hpf.
Free-floating fat droplets also stain or polarize depending on their composition. They may be observed floating on
the top of the specimen. Care should be taken not to confuse
the droplets with starch and crystal particles that also polarize. Specimen contamination by vaginal preparations and
Figure 6–33 Oval fat body (×400).
Figure 6–32 Prussian blue–stained hemosiderin granules.
Figure 6–34 Sudan III-stained oval fat body (×400).
3920_Ch06_099-146 23/01/14 10:18 AM Page 118
118
Part Two | Urinalysis
Brightfield
Polarized
SUMMARY 6-3
Epithelial Cells
Squamous Cells
Appearance:
Sources of error:
Reporting:
Figure 6–35 Oval fat body under bright-field (left) and polarized
(right) microscopy. Notice the Maltese cross formation (arrow)
(×400).
lubricants used in specimen collection must be considered
when only free-floating fat droplets are present.
Lipiduria is most frequently associated with damage to the
glomerulus caused by the nephrotic syndrome (see Chapter 7).
It is also seen with severe tubular necrosis, diabetes mellitus,
and in trauma cases that cause release of bone marrow fat from
the long bones. In lipid-storage diseases, large fat-laden histiocytes may also be present. They can be differentiated from
oval fat bodies by their large size.
In cases of acute tubular necrosis, RTE cells containing
large, nonlipid-filled vacuoles may be seen along with normal
renal tubular cells and oval fat bodies. Referred to as “bubble
cells,” they appear to represent injured cells in which the
endoplasmic reticulum has dilated prior to cell death.18
Complete urinalysis
correlations:
Largest cells in the sediment
with abundant, irregular
cytoplasm and prominent
nuclei
Rarely encountered, folded cells
may resemble casts
Rare, few, moderate, or many
per lpf
Clarity
Transitional Cells
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Spherical, polyhedral, or caudate with centrally located
nucleus
Spherical forms resemble RTE
cells
Rare, few, moderate, or many per
hpf
Clarity
Blood, if malignancyassociated
RTE Cells
Appearance:
Bacteria
Sources of error:
Bacteria are not normally present in urine. However, unless
specimens are collected under sterile conditions (catheterization), a few bacteria are usually present as a result of vaginal,
urethral, external genitalia, or collection-container contamination. These contaminant bacteria multiply rapidly in specimens
that remain at room temperature for extended periods, but are
of no clinical significance. They may produce a positive nitrite
test result and also frequently result in a pH above 8, indicating
an unacceptable specimen.
Bacteria may be present in the form of cocci (spherical)
or bacilli (rods). Owing to their small size, they must be observed and reported using high-power magnification. They
are reported as few, moderate, or many per high-power field.
To be considered significant for UTI, bacteria should be accompanied by WBCs. Some laboratories report bacteria only
when observed in fresh specimens in conjunction with WBCs
(Fig. 6–36 A and B). The presence of motile organisms in a
drop of fresh urine collected under sterile conditions correlates well with a positive urine culture. Observing bacteria for
motility also is useful in differentiating them from similarly
appearing amorphous phosphates and urates. The use of
phase microscopy aids in the visualization of bacteria.
Reporting:
Complete urinalysis
correlations:
Rectangular, columnar, round,
oval or, cuboidal with an eccentric nucleus possibly bilirubinstained or hemosiderin-laden
Spherical transitional cells
Granular casts
Average number per 10 hpfs
Leukocyte esterase and nitrite
(pyelonephritis)
Color
Clarity
Protein
Bilirubin (hepatitis)
Blood
Oval Fat Bodies
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Highly refractile RTE cells
Confirm with fat stains and
polarized microscopy
Average number per hpf
Clarity
Blood
Protein
Free fat droplets/fatty casts
3920_Ch06_099-146 23/01/14 10:18 AM Page 119
Chapter 6 | Microscopic Examination of Urine 119
A
B
A
B
Figure 6–36 A. Rod-shaped bacteria often seen in urinary tract infections. B. KOVA-stained bacteria and WBC (×400).
Figure 6–37 A. Budding yeast B. Yeast showing mycelial forms
(×400).
The presence of bacteria can be indicative of either lower
or upper UTI. Specimens containing increased bacteria and
leukocytes are routinely followed up with a specimen for quantitative urine culture. The bacteria most frequently associated
with UTI are the Enterobacteriaceae (referred to as gramnegative rods); however, the cocci-shaped Staphylococcus and
Enterococcus are also capable of causing UTI. The actual bacteria producing an UTI cannot be identified with the microscopic
examination.
the growth of yeast. As with bacteria, a small amount of yeast
entering a specimen as a contaminant multiplies rapidly if the
specimen is not examined while fresh. A true yeast infection
should be accompanied by the presence of WBCs.
Yeast
Yeast cells appear in the urine as small, refractile oval structures
that may or may not contain a bud. In severe infections, they
may appear as branched, mycelial forms (Fig. 6–37 A and B).
Yeast cells are reported as rare, few, moderate, or many per hpf.
Differentiation between yeast cells and RBCs can sometimes be difficult. Careful observation for budding yeast cells
should be helpful, as shown in Figure 6–10.
Yeast cells, primarily Candida albicans, are seen in the urine
of diabetic patients, immunocompromised patients, and
women with vaginal moniliasis. The acidic, glucose-containing
urine of patients with diabetes provides an ideal medium for
Parasites
The most frequent parasite encountered in the urine is
Trichomonas vaginalis. The Trichomonas trophozoite is a pearshaped flagellate with an undulating membrane. It is easily
identified in wet preparations of the urine sediment by its rapid
darting movement in the microscopic field. Trichomonas is usually reported as rare, few, moderate, or many per hpf.
When not moving, Trichomonas is more difficult to identify
and may resemble a WBC, transitional, or RTE cell. Use of
phase microscopy may enhance visualization of the flagella or
undulating membrane.
T. vaginalis is a sexually transmitted pathogen associated
primarily with vaginal inflammation. Infection of the male
urethra and prostate is asymptomatic. Males are often asymptomatic carriers (Fig. 6–38).
The ova of the bladder parasite Schistosoma haematobium
will appear in the urine. However, this parasite is seldom seen
3920_Ch06_099-146 23/01/14 10:19 AM Page 120
120
Part Two | Urinalysis
Figure 6–38 Trichomonas vaginalis. Notice the flagella and undulating membrane. (From Leventhal and Cheadle, Ed 6, p 87).
A
in the United States. It has been associated with bladder
cancer in other countries (Fig. 6–39). Fecal contamination of
a urine specimen can also result in the presence of ova from
intestinal parasites in the urine sediment. The most common
contaminant is ova from the pinworm Enterobius vermicularis
(Fig. 6–40 A and B).
Spermatozoa
Spermatozoa are easily identified in the urine sediment by
their oval, slightly tapered heads and long, flagella-like tails
(Fig. 6–41). Urine is toxic to spermatozoa; therefore, they
rarely exhibit the motility observed when examining a semen
specimen.
Spermatozoa are occasionally found in the urine of both
men and women following sexual intercourse, masturbation,
or nocturnal emission. They are rarely of clinical significance
except in cases of male infertility or retrograde ejaculation in
which sperm is expelled into the bladder instead of the urethra.
A positive reagent strip test for protein may be seen when increased amounts of semen are present.
Laboratory protocols vary with regard to reporting or
not reporting the presence of spermatozoa in a urine specimen. Laboratories not reporting its presence cite the lack of
clinical significance and possible legal consequences. Laboratories supporting the reporting of spermatozoa cite the
possible clinical significance and the minimal possibility of
legal consequences.19
B
Figure 6–40 A. Enterobius vermicularis ova (×100) B. Enterobius vermicularis ova (×400).
Figure 6–41 Spermatozoa (×400).
Mucus
Figure 6–39 Schistosoma haematobium ova (×300). Eggs are often
contained in the last few drops of urine expelled from the bladder.
Mucus is a protein material produced by the glands and epithelial cells of the lower genitourinary tract and the RTE cells.
Immunologic analysis has shown that uromodulin is a major
constituent of mucus. Uromodulin is a glycoprotein excreted
by the RTE cells of the distal convoluted tubules and upper
collecting ducts.
Mucus appears microscopically as thread-like structures
with a low refractive index. Subdued light is required when
using bright-field microscopy. Care must be taken not to confuse clumps of mucus with hyaline casts. The differentiation
3920_Ch06_099-146 23/01/14 10:19 AM Page 121
Chapter 6 | Microscopic Examination of Urine 121
can usually be made by observing the irregular appearance of
the mucous threads (Fig. 6–42 A and B).
Mucus threads are reported as rare, few, moderate, or
many per lpf.
Mucus is more frequently present in female urine specimens. It has no clinical significance when present in either
female or male urine.
Casts
Casts are the only elements found in the urinary sediment that
are unique to the kidney. They are formed within the lumens
of the distal convoluted tubules and collecting ducts, providing
a microscopic view of conditions within the nephron. Their
shape is representative of the tubular lumen, with parallel sides
and somewhat rounded ends, and they may contain additional
elements present in the filtrate.
Examination of the sediment for the detection of casts is
performed using lower power magnification. When the glass
cover-slip method is used, low-power scanning should be performed along the edges of the cover slip. Observation under
subdued light is essential, because the cast matrix has a low
refractive index. Similar to many other sediment constituents,
SUMMARY 6-4
Miscellaneous Structures
Bacteria
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Small spherical and rod-shaped
structures
Amorphous phosphates and
urates
Few, moderate, or many per hpf,
the presence of WBCs may be
required
pH
Nitrite
LE
WBCs
Yeast
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Small, oval, refractile structures
with buds and/or mycelia
RBCs
Rare, few, moderate, or many per
hpf, the presence of WBCs may
be required
Glucose
LE
WBCs
Trichomonas
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
A
Pear-shaped, motile, flagellated
WBCs, renal tubular epithelial cells
Rare, few, moderate, or many per
hpf
LE
WBCs
Spermatozoa
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Tapered oval head with long,
thin tail
None
Present, based on laboratory
protocol
Protein
Mucus
Appearance:
Sources of error:
Reporting:
B
Figure 6–42 A. Mucus threads (×400). B. Mucus clump (×400).
Complete urinalysis
correlations:
Single or clumped threads with a
low refractive index
Hyaline casts
Rare, few, moderate, or many
per lpf
None
3920_Ch06_099-146 23/01/14 10:19 AM Page 122
122
Part Two | Urinalysis
the cast matrix dissolves quickly in dilute, alkaline urine. Once
detected, casts must be further identified as to composition
using high-power magnification. They are reported as the
average number per 10 lpfs.
clinical conditions and will be discussed separately in this
section.
Cast Composition and Formation
The most frequently seen cast is the hyaline type, which consists
almost entirely of uromodulin. The presence of zero to two hyaline casts per lpf is considered normal, as is the finding of
increased numbers following strenuous exercise, dehydration,
heat exposure, and emotional stress.15 Pathologically, hyaline
casts are increased in acute glomerulonephritis, pyelonephritis,
chronic renal disease, and congestive heart failure.
Hyaline casts appear colorless in unstained sediments and
have a refractive index similar to that of urine; thus, they can
easily be overlooked if specimens are not examined under subdued light (Figs. 6–43 and 6–44). Sternheimer-Malbin stain
produces a pink color in hyaline casts. Increased visualization
can be obtained by phase microscopy (Fig. 6–45 A and B).
The morphology of hyaline casts is varied, consisting of
normal parallel sides and rounded ends, cylindroid forms, and
wrinkled or convoluted shapes that indicate aging of the cast
matrix (Fig. 6–46). The presence of an occasional adhering cell
or granule may also be observed (Fig. 6–47) but does not
change the cast classification.
The major constituent of casts is uromodulin. Other proteins
present in the urinary filtrate, such as albumin and immunoglobulins, are also incorporated into the cast matrix.
Under normal conditions, uromodulin is excreted at a relatively constant rate. The rate of excretion appears to increase
under conditions of stress and exercise, which may account
for the transient appearance of hyaline casts when these conditions are present. The protein gels more readily under
conditions of urine-flow stasis, acidity, and the presence of
sodium and calcium. The extent of protein glycosylation is
also important.20 Uromodulin protein is found in both normal
and abnormal urine and, as discussed previously, is a major
constituent of mucus. It is not detected by reagent strip protein methods. Therefore, the increased urinary protein frequently associated with the presence of casts is caused by
underlying renal conditions.
Scanning electron microscope studies have provided a
step-by-step analysis of the formation of the uromodulin protein matrix21:
1. Aggregation of uromodulin protein into individual protein fibrils attached to the RTE cells
2. Interweaving of protein fibrils to form a loose fibrillar
network (urinary constituents may become enmeshed
in the network at this time)
3. Further protein fibril interweaving to form a solid
structure
4. Possible attachment of urinary constituents to the solid
matrix
5. Detachment of protein fibrils from the epithelial cells
6. Excretion of the cast
As the cast forms, urinary flow within the tubule decreases as the lumen becomes blocked. The accompanying
dehydration of the protein fibrils and internal tension may
account for the wrinkled and convoluted appearance of older
hyaline casts.22 The width of the cast depends on the size of
the tubule in which it is formed. Broad casts may result from
tubular distension or, in the case of extreme urine stasis,
from formation in the collecting ducts. Formation of casts at
the junction of the ascending loop of Henle and the distal
convoluted tubule may produce structures with a tapered
end. These have been referred to as cylindroids, but they
have the same significance as casts. In fact, the presence of
urinary casts is termed cylindruria. The appearance of a cast
is also influenced by the materials present in the filtrate at
the time of its formation and the length of time it remains
in the tubule. Any elements present in the tubular filtrate,
including cells, bacteria, granules, pigments, and crystals,
may become embedded in or attached to the cast matrix.
The types of casts found in the sediment represent different
Hyaline Casts
Figure 6–43 Hyaline casts under low power (×100).
A
B
Figure 6–44 Hyaline cast (A) and amorphous urates (B) attached to
mucus pseudocast (×100).
3920_Ch06_099-146 23/01/14 10:19 AM Page 123
Chapter 6 | Microscopic Examination of Urine 123
A
Figure 6–47 Hyaline cast containing occasional granules (×400).
casts have also been observed in healthy individuals following
participation in strenuous contact sports.15
RBC casts are easily detected under low power by their
orange-red color. They are more fragile than other casts and
may exist as fragments or have a more irregular shape as the
result of tightly packed cells adhering to the protein matrix
(Figs. 6–48 and 6–49). Examination under high-power magnification should concentrate on determining that a cast matrix is present, thereby differentiating the structure from a
B
Figure 6–45 A. Hyaline cast (×400). B. Hyaline cast under phase
microscopy (×400).
Figure 6–48 RBC cast (×400).
Figure 6–46 Convoluted hyaline cast (×400).
RBC Casts
Whereas the finding of RBCs in the urine indicates bleeding
from an area within the genitourinary tract, the presence of
RBC casts is much more specific, showing bleeding within the
nephron. RBC casts are primarily associated with damage to
the glomerulus (glomerulonephritis) that allows passage of the
cells through the glomerular membrane; however, any damage
to the nephron capillary structure can cause their formation.
RBC casts associated with glomerular damage are usually
associated with proteinuria and dysmorphic erythrocytes. RBC
Figure 6–49 KOVA-stained RBC cast under phase microscopy
(×400).
3920_Ch06_099-146 23/01/14 10:19 AM Page 124
Part Two | Urinalysis
124
clump of RBCs. Because of the serious diagnostic implications
of RBC casts, the actual presence of RBCs must also be verified
to prevent the inaccurate reporting of nonexistent RBC casts.
It is highly improbable that RBC casts will be present in the
absence of free-standing RBCs and a positive reagent strip test
for blood (Fig. 6–50).
As an RBC cast ages, cell lysis begins and the cast develops
a more homogenous appearance, but retains the characteristic
orange-red color from the released hemoglobin (Fig. 6–51).
These casts may be distinguished as blood casts, indicating
greater stasis of urine flow. However, because all casts containing blood have the same clinical significance, this is not considered necessary. Both types of casts are reported as the
number of RBC casts per lpf.
In the presence of massive hemoglobinuria or myoglobinuria, homogenous orange-red or red-brown casts may be observed. Granular, dirty, brown casts representing hemoglobin
degradation products such as methemoglobin may also be
present (Fig. 6–52). They are associated with the acute tubular
necrosis often caused by the toxic effects of massive hemoglobinuria that can lead to renal failure. These dirty, brown casts
must be present in conjunction with other pathologic findings
such as RTE cells and a positive reagent strip test for blood.
Figure 6–52 Granular, dirty, brown cast (×400).
WBC Casts
The appearance of WBC casts in the urine signifies infection
or inflammation within the nephron. They are most frequently
associated with pyelonephritis and are a primary marker for
distinguishing pyelonephritis (upper UTI) from cystitis (lower
UTI). However, they are also present in nonbacterial inflammations such as acute interstitial nephritis and may accompany
RBC casts in glomerulonephritis.
WBC casts are visible under low-power magnification but
must be positively identified using high power. Most frequently,
WBC casts are composed of neutrophils; therefore, they may
appear granular, and, unless disintegration has occurred, multilobed nuclei will be present (Fig. 6–53). Supravital staining
may be necessary to demonstrate the characteristic nuclei
(Fig. 6–54). It is particularly helpful for differentiating WBC
casts from RTE casts. Observation of free WBCs in the sediment
is also essential (Fig. 6–55). Bacteria are present in cases of
pyelonephritis, but are not present with acute interstitial nephritis; however, eosinophil casts may be present in appropriately
stained specimens (Hansel and Wright’s stains).
Figure 6–50 Disintegrating RBC cast. Notice the presence of free
RBCs (arrows) to confirm identification.
A
B
Figure 6–51 Cast containing hemoglobin pigment. A comparison of
RBCs (A) and yeast (B) also can be made (×400).
Figure 6–53 WBC cast. Notice the free WBCs to aid in identification.
3920_Ch06_099-146 23/01/14 10:19 AM Page 125
Chapter 6 | Microscopic Examination of Urine 125
Identification of bacterial casts can be difficult, because
packed casts packed with bacteria can resemble granular casts.
Their presence should be considered when WBC casts and
many free WBCs and bacteria are seen in the sediment. Confirmation of bacterial casts is best made by performing a Gram
stain on the dried or cytocentrifuged sediment.
Epithelial Cell Casts
Figure 6–54 KOVA-stained WBC cast (×400).
Figure 6–55 Disintegrating WBC cast (×400).
Casts tightly packed with WBCs may have irregular borders.
These structures should be carefully examined to determine that
a cast matrix is present. WBCs frequently form clumps, and
these do not have the same significance as casts (Fig. 6–56).
Bacterial Casts
Bacterial casts containing bacilli both within and bound to the
protein matrix are seen in pyelonephritis.23 They may be pure
bacterial casts or mixed with WBCs.
Figure 6–56 WBC clump. Notice the absence of a cast matrix.
Casts containing RTE cells represent the presence of advanced
tubular destruction, producing urinary stasis along with disruption of the tubular linings. Similar to RTE cells, they are
associated with heavy metal and chemical or drug-induced toxicity, viral infections, and allograft rejection. They also accompany WBC casts in cases of pyelonephritis.
As discussed previously, the fibrils of uromodulin protein
that make up the cast matrix remain attached to the RTE cells
that produce them; therefore, the observation of an occasional
tubular cell attached to a hyaline cast can be expected. When
tubular damage is present, some cells may be incorporated
into the cast matrix, but the majority will be very noticeably
attached to the cast surface.
Owing to the formation of casts in the distal convoluted
tubule, the cells visible on the cast matrix are the smaller,
round, and oval cells (Fig. 6–57). They may be difficult to differentiate from WBCs, particularly if degeneration has occurred. Staining and the use of phase microscopy can be
helpful to enhance the nuclear detail needed for identification
(Figs. 6–58 A and B and 6–59). Fragments of epithelial tissue
may also be attached to the cast matrix. Bilirubin-stained RTE
cells are seen in cases of hepatitis (see Fig. 6–59).
Fatty Casts
Fatty casts are seen in conjunction with oval fat bodies and
free fat droplets in disorders causing lipiduria. They are most
frequently associated with the nephrotic syndrome, but are
also seen in toxic tubular necrosis, diabetes mellitus, and
crush injuries.
Fatty casts are highly refractile under bright-field microscopy. The cast matrix may contain few or many fat
droplets, and intact oval fat bodies may be attached to the
Figure 6–57 RTE cell cast (×400).
3920_Ch06_099-146 23/01/14 10:19 AM Page 126
126
Part Two | Urinalysis
A
Figure 6–60 Fatty cast showing adherence of fat droplets (arrows) to
cast matrix (×400).
B
Figure 6–58 A. KOVA-stained RTE cell cast (×400). B. KOVA-stained
RTE cell cast under phase microscopy (×400).
Figure 6–61 Fatty cast (×400).
Figure 6–59 RTE cast with bilirubin-stained cells (×400).
matrix (Figs. 6–60, 6–61, 6–62). Confirmation of fatty casts
is performed using polarized microscopy and Sudan III or Oil
Red O fat stains. As discussed previously, cholesterol demonstrates characteristic Maltese cross formations under polarized
light, and triglycerides and neutral fats stain orange with fat
stains. Fats do not stain with Sternheimer-Malbin stains.
Mixed Cellular Casts
Considering that a variety of cells may be present in the urinary filtrate, observing casts containing multiple cell types
is not uncommon. Mixed cellular casts most frequently
Figure 6–62 Fatty cast under phase microscopy (×400).
encountered include RBC and WBC casts in glomerulonephritis and WBC and RTE cell casts, or WBC and bacterial casts in pyelonephritis.
The presence of mixed elements in a cast may make identification more difficult. Staining or phase microscopy aids in
the identification. When mixed casts are present, there should
also be homogenous casts of at least one of the cell types, and
they will be the primary diagnostic marker. For example, in
3920_Ch06_099-146 23/01/14 10:19 AM Page 127
Chapter 6 | Microscopic Examination of Urine 127
glomerulonephritis, the predominant casts will be RBC, and
in pyelonephritis, the predominant casts will be WBC. Bacteria
are often incorporated into WBC casts and provide little additional diagnostic significance. Laboratory protocol should be
followed in the reporting of mixed cellular casts.
Granular Casts
Coarsely and finely granular casts are frequently seen in the
urinary sediment and may be of pathologic or nonpathologic
significance. It is not considered necessary to distinguish between coarsely and finely granular casts.
The origin of the granules in nonpathologic conditions
appears to be from the lysosomes excreted by RTE cells during normal metabolism.24 It is not unusual to see hyaline casts
containing one or two of these granules. Increased cellular
metabolism occurring during periods of strenuous exercise accounts for the transient increase of granular casts that accompany the increased hyaline casts (Figs. 6–63 and 6–64).15 In
disease states, granules may represent disintegration of cellular
casts and tubule cells or protein aggregates filtered by the
glomerulus (Figs. 6–65 and 6–66). Scanning electron microscope studies have confirmed that granular casts seen in conjunction with WBC casts contain WBC granules of varying
sizes.25 Urinary stasis allowing the casts to remain in the
Figure 6–65 Granular disintegrating cellular cast (×400).
B
C
A
B
Figure 6–66 Coarsely granular cast (A), squamous epithelial cell (B),
and mucus (C) (×400).
A
Figure 6–63 Finely granular cast (A) and uric acid crystals (B) (×400).
tubules must be present for granules to result from disintegration of cellular casts.
Granular casts occurring as a result of cellular disintegration may contain an occasional recognizable cell. Granular
casts are easily visualized under low-power microscopy. However, final identification should be performed using high power
to determine the presence of a cast matrix.
Artifacts, such as clumps of small crystals and fecal debris,
may occur in shapes resembling casts and must be differentiated. As mentioned previously, columnar RTE cells may also
resemble granular casts, and staining for nuclear detail may be
required.
When granular casts remain in the tubules for extended
periods, the granules further disintegrate, and the cast matrix
develops a waxy appearance. The structure becomes more
rigid, the ends of the casts may appear jagged or broken, and
the diameter becomes broader (Fig. 6–67).
Waxy Casts
Figure 6–64 Granular cast formed at a tubular bend (×400).
Waxy casts are representative of extreme urine stasis, indicating
chronic renal failure. They are usually seen in conjunction with
other types of casts associated with the condition that has
caused the renal failure.
3920_Ch06_099-146 23/01/14 10:19 AM Page 128
128
Part Two | Urinalysis
Figure 6–67 Granular cast degenerating into waxy cast (×400).
Figure 6–70 KOVA-stained waxy cast (×400).
The brittle, highly refractive cast matrix from which these
casts derive their name is believed to be caused by degeneration of the hyaline cast matrix and any cellular elements or
granules contained in the matrix.22,24
Waxy casts are more easily visualized than hyaline casts
because of their higher refractive index. As a result of the brittle
consistency of the cast matrix, they often appear fragmented
with jagged ends and have notches in their sides (Figs. 6–68
and 6–69). With supravital stains, waxy casts stain a homogenous, dark pink (Fig. 6–70).
Broad Casts
Often referred to as renal failure casts, broad casts like waxy
casts represent extreme urine stasis. As a mold of the distal
convoluted tubules, the presence of broad casts indicates destruction (widening) of the tubular walls. Also, when the flow
of urine to the larger collecting ducts becomes severely compromised, casts form in this area and appear broad.
All types of casts may occur in the broad form. However,
considering the accompanying urinary stasis, the most commonly seen broad casts are granular and waxy (Figs. 6–71 and
6–72). Bile-stained broad, waxy casts are seen as the result of
the tubular necrosis caused by viral hepatitis (Fig. 6–73).
Urinary Crystals
Figure 6–68 KOVA-stained waxy casts (×100).
Figure 6–69 KOVA-stained waxy casts (×200).
Crystals frequently found in the urine are rarely of clinical significance. They may appear as true geometrically formed structures or as amorphous material. The primary reason for the
identification of urinary crystals is to detect the presence of the
relatively few abnormal types that may represent such disorders as liver disease, inborn errors of metabolism, or renal
damage caused by crystallization of medications compounds
within the tubules. Crystals are usually reported as rare, few,
moderate, or many per hpf. Abnormal crystals may be averaged
and reported per lpf.
Figure 6–71 KOVA-stained broad waxy cast (×400).
3920_Ch06_099-146 23/01/14 10:19 AM Page 129
Chapter 6 | Microscopic Examination of Urine 129
Crystal Formation
Figure 6–72 Broad granular cast becoming waxy (×400).
Crystals are formed by the precipitation of urine solutes, including inorganic salts, organic compounds, and medications
(iatrogenic compounds). Precipitation is subject to changes
in temperature, solute concentration, and pH, which affect
solubility.
Solutes precipitate more readily at low temperatures.
Therefore, the majority of crystal formation takes place in specimens that have remained at room temperature or been refrigerated prior to testing. Crystals are extremely abundant in
refrigerated specimens and often present problems because
they obscure clinically significant sediment constituents.
As the concentration of urinary solutes increases, their ability
to remain in solution decreases, resulting in crystal formation.
The presence of crystals in freshly voided urine is most frequently
associated with concentrated (high specific gravity) specimens.
A valuable aid in the identification of crystals is the pH of
the specimen because this determines the type of chemicals precipitated. In general, organic and iatrogenic compounds crystallize more easily in an acidic pH, whereas inorganic salts are less
soluble in neutral and alkaline solutions. An exception is calcium
oxalate, which precipitates in both acidic and neutral urine.
General Identification Techniques
Figure 6–73 Broad bile-stained waxy cast (×400).
SUMMARY 6-5
Urine Casts
Hyaline
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
The most commonly seen crystals have very characteristic
shapes and colors; however, variations do occur and can present
identification problems, particularly when they resemble abnormal crystals. As discussed previously, the first consideration
when identifying crystals is the urine pH. In fact, crystals are
routinely classified not only as normal and abnormal, but also
Colorless, homogenous matrix
Mucus, fibers, hair, increased
lighting
Average number per lpf
Protein
Blood (exercise)
Color (exercise)
Glomerulonephritis
Pyelonephritis
Chronic renal disease
Congestive heart failure
Stress and exercise
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
WBC
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
RBC
Appearance:
Orange-red color, cast matrix
containing RBCs
RBC clumps
Average number per lpf
RBCs
Blood
Protein
Glomerulonephritis
Strenuous exercise
Clinical significance:
Cast matrix containing WBCs
WBC clumps
Average number per lpf
WBCs
Protein
LE
Pyelonephritis
Acute interstitial nephritis
Continued
3920_Ch06_099-146 23/01/14 10:19 AM Page 130
130
Part Two | Urinalysis
SUMMARY 6-5
Urine Casts—cont’d
Bacterial
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
Bacilli bound to protein matrix
Granular casts
Average number per lpf
WBC casts (pyelonephritis)
WBCs
LE
Nitrite
Protein
Bacteria
Pyelonephritis
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
Fatty
Appearance:
Epithelial Cell
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
RTE cells attached to protein
matrix
WBC cast
Average number per lpf
Protein
RTE cells
Renal tubular damage
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
Granular
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
Coarse and fine granules in a
cast matrix
Clumps of small crystals
Columnar RTE cells
Average number per lpf
Protein
Cellular casts
RBCs
WBCs
Glomerulonephritis
Pyelonephritis
Stress and exercise
Waxy
Appearance:
Fibers and fecal material
Average number per lpf
Protein
Cellular casts
Granular casts
WBCs
RBCs
Stasis of urine flow
Chronic renal failure
Fat droplets and oval fat
bodies attached to protein
matrix
Fecal debris
Average number per lpf
Protein
Free fat droplets
Oval fat bodies
Nephrotic syndrome
Toxic tubular necrosis
Diabetes mellitus
Crush injuries
Broad
Appearance:
Sources of error:
Reporting:
Complete urinalysis
correlations:
Clinical significance:
Wider than normal cast matrix
Fecal material, fibers
Average number per lpf
Protein
WBCs
RBCs
Granular casts
Waxy casts
Extreme urine stasis
Renal failure
Highly refractile cast with
jagged ends and notches
as to their appearance in acidic or alkaline urine. All abnormal
crystals are found in acidic urine.
Additional aids in crystal identification include the use of
polarized microscopy and solubility characteristics of the crystals. The geometric shape of a crystal determines its birefringence and, therefore, its ability to polarize light. Although the
size of a particular crystal may vary (slower crystallization produces larger crystals), the basic structure remains the same.
Therefore, polarization characteristics for a particular crystal
are constant for identification purposes.
Just as changes in temperature and pH contribute
to crystal formation, reversal of these changes can cause
crystals to dissolve. These solubility characteristics can be
used to aid in identification. Amorphous urates that
frequently form in refrigerated specimens and obscure sediments may dissolve if the specimen is warmed. Amorphous
phosphates require acetic acid to dissolve, and this is
not practical, as formed elements, such as RBCs, will also be
destroyed. When solubility characteristics are needed
for identification, the sediment should be aliquoted to
3920_Ch06_099-146 23/01/14 10:19 AM Page 131
Chapter 6 | Microscopic Examination of Urine 131
prevent destruction of other elements. In Table 6–6, characteristics for the most commonly encountered crystals are
provided.
Normal Crystals Seen in Acidic Urine
The most common crystals seen in acidic urine are urates, consisting of amorphous urates, uric acid, acid urates, and sodium
urates. Microscopically, most urate crystals appear yellow to
reddish brown and are the only normal crystals found in acidic
urine that appear colored.
Table 6–6
Amorphous urates appear microscopically as yellowbrown granules (Fig. 6–74). They may occur in clumps resembling granular casts and attached to other sediment structures
(Fig.6–75). Amorphous urates are frequently encountered in
specimens that have been refrigerated and produce a very characteristic pink sediment. Accumulation of the pigment, uroerythrin, on the surface of the granules is the cause of the pink
color. Amorphous urates are found in acidic urine with a pH
greater than 5.5, whereas uric acid crystals can appear when
the pH is lower.
Major Characteristics of Normal Urinary Crystals
Crystal
pH
Color
Uric acid
Acid
Yellow-brown (rosettes,
wedges)
Amorphous urates
Acid
Brick dust or yellow
brown
Calcium oxalate
Acid/neutral
(alkaline)
Colorless (envelopes,
oval, dumbbell)
Amorphous phosphates
Alkaline/
neutral
White–colorless
Calcium phosphate
Alkaline/
neutral
Colorless
Triple phosphate
Alkaline
Colorless (“coffin lids”)
Ammonium biurate
Alkaline
Yellow-brown (“thorny
apples”)
Calcium carbonate
Alkaline
Colorless (dumbbells)
Appearance
3920_Ch06_099-146 23/01/14 10:19 AM Page 132
132
Part Two | Urinalysis
Figure 6–74 Amorphous urates (×400).
Figure 6–77 Clump of uric acid crystals (×400). Notice the whetstone,
not hexagonal, shape that differentiates uric acid crystals from cystine
crystals.
cystine crystals (Fig. 6–78 A and B). Increased amounts of uric
acid crystals, particularly in fresh urine, are associated with increased levels of purines and nucleic acids and are seen in patients with leukemia who are receiving chemotherapy, in
patients with Lesch-Nyhan syndrome (see Chapter 8), and
sometimes in patients with gout.
Acid urates and sodium urates are rarely encountered and,
like amorphous urates, are seen in less acidic urine. They are
frequently seen in conjunction with amorphous urates and
Figure 6–75 Amorphous urates attached to a fiber.
Uric acid crystals are seen in a variety of shapes, including
rhombic, four-sided flat plates (whetstones), wedges, and
rosettes. They usually appear yellow-brown, but may be colorless and have a six-sided shape, similar to cystine crystals
(Figs. 6–76 and 6–77). Uric acid crystals are highly birefringent
under polarized light, which aids in distinguishing them from
A
B
Figure 6–76 Uric acid crystals (×400).
Figure 6–78 A. Uric acid crystals under polarized light (×100). B. Uric
acid crystals under polarized light (×400).
3920_Ch06_099-146 23/01/14 10:19 AM Page 133
Chapter 6 | Microscopic Examination of Urine 133
have little clinical significance. Acid urates appear as larger
granules and may have spicules similar to the ammonium
biurate crystals seen in alkaline urine. Sodium urate crystals
are needle-shaped and are seen in synovial fluid during
episodes of gout, but may also appear in the urine.
Calcium oxalate crystals are frequently seen in acidic
urine, but they can be found in neutral urine and even rarely
in alkaline urine. The most common form of calcium oxalate
crystals is the dihydrate that is easily recognized as a colorless,
octahedral envelope or as two pyramids joined at their bases
(Figs. 6–79, 6–80, and 6–81). Less characteristic and less frequently seen is the monohydrate form (Fig. 6–82). Monohydrate calcium oxalate crystals are oval or dumbbell shaped.
Both the dihydrate and monohydrate forms are birefringent
under polarized light. This may be helpful to distinguish the
monohydrate form from nonpolarizing RBCs. Calcium oxalate
crystals are sometimes seen in clumps attached to mucous
strands and may resemble casts.
The finding of clumps of calcium oxalate crystals in fresh
urine may be related to the formation of renal calculi, because
the majority of renal calculi are composed of calcium oxalate.
They are also associated with foods high in oxalic acid, such
Figure 6–81 Attached classic dihydrate calcium oxalate crystals
(×400).
Figure 6–82 Monohydrate calcium oxalate crystals (×400).
Figure 6–79 Classic dihydrate calcium oxalate crystals (×400).
as tomatoes and asparagus, and ascorbic acid, because oxalic
acid is an end product of ascorbic acid metabolism. The primary pathologic significance of calcium oxalate crystals is the
very noticeable presence of the monohydrate form in cases of
ethylene glycol (antifreeze) poisoning. The monohydrate form
is most frequently seen in children and pets because antifreeze
tastes sweet and uncovered containers left in the garage can be
very tempting! Massive amounts of crystals are frequently produced in these cases.
Normal Crystals Seen in Alkaline Urine
Figure 6–80 Classic dihydrate calcium oxalate crystals under phase
microscopy (×400).
Phosphates represent the majority of the crystals seen in
alkaline urine and include amorphous phosphate, triple phosphate, and calcium phosphate. Other normal crystals associated with alkaline urine are calcium carbonate and ammonium
biurate. Amorphous phosphates are granular in appearance,
similar to amorphous urates (Figs. 6–83 and 6–84). When
present in large quantities following specimen refrigeration,
they cause a white precipitate that does not dissolve on warming. They can be differentiated from amorphous urates by the
color of the sediment and the urine pH.
3920_Ch06_099-146 23/01/14 10:19 AM Page 134
134
Part Two | Urinalysis
Figure 6–83 Amorphous phosphates (×400). Urine pH 7.0.
Figure 6–86 Triple phosphate crystals (arrow) and amorphous phosphates (×400).
Figure 6–87 Calcium carbonate crystals (×400).
Figure 6–84 Amorphous phosphates (×400).
Triple phosphate (ammonium magnesium phosphate)
crystals are commonly seen in alkaline urine. In their routine
form, they are easily identified by their prism shape that frequently resembles a “coffin lid” (Figs. 6–85 and 6–86). As they
disintegrate, the crystals may develop a feathery appearance.
Figure 6–85 Triple phosphate crystal (×400).
Triple phosphate crystals are birefringent under polarized light.
They have no clinical significance; however, they are often seen
in highly alkaline urine associated with the presence of ureasplitting bacteria.
Calcium phosphate crystals are not frequently encountered. They may appear as colorless, flat rectangular plates or
thin prisms often in rosette formations. The rosette forms may
be confused with sulfonamide crystals when the urine pH is
in the neutral range. Calcium phosphate crystals dissolve in
dilute acetic acid and sulfonamides do not. They have no clinical significance, although calcium phosphate is a common
constituent of renal calculi.
Calcium carbonate crystals are small and colorless, with
dumbbell or spherical shapes (Fig. 6–87). They may occur in
clumps that resemble amorphous material, but they can be distinguished by the formation of gas after the addition of acetic
acid. They are also birefringent, which differentiates them from
bacteria. Calcium carbonate crystals have no clinical significance.
Ammonium biurate crystals exhibit the characteristic
yellow-brown color of the urate crystals seen in acidic urine.
They are frequently described as “thorny apples” because of
their appearance as spicule-covered spheres (Fig. 6–88). Except for their occurrence in alkaline urine, ammonium biurate
crystals resemble other urates in that they dissolve at 60°C and
3920_Ch06_099-146 23/01/14 10:19 AM Page 135
Chapter 6 | Microscopic Examination of Urine 135
Figure 6–88 Ammonium biurate crystals (×400). Notice the “thorny
apple” appearance. (Courtesy of Kenneth L. McCoy, MD.)
convert to uric acid crystals when glacial acetic acid is added.
Ammonium biurate crystals are almost always encountered in
old specimens and may be associated with the presence of the
ammonia produced by urea-splitting bacteria (Figs. 6–89 A
and B and 6–90).
Figure 6–90 Ammonium biurate crystals (×400). Note thorns (arrow).
Abnormal Urine Crystals
Abnormal urine crystals are found in acidic urine or rarely
in neutral urine. Most abnormal crystals have very characteristic shapes. However, their identity can be confirmed by
patient information, including disorders and medication
(Table 6–7). Iatrogenic crystals can be caused by a variety
of compounds, particularly when they are administered in
high concentrations. They may be of clinical significance
when they precipitate in the renal tubules. The most commonly encountered iatrogenic crystals are discussed in this
section.
A
B
Figure 6–89 Ammonium biurate crystals A. Ammonium biurate and
triple phosphate crystals (×100). Note thorn (arrow). B. Ammonium
biurate and triple phosphate crystals (×400).
Cystine Crystals
Cystine crystals are found in the urine of persons who inherit
a metabolic disorder that prevents reabsorption of cystine by
the renal tubules (cystinuria). Persons with cystinuria have a
tendency to form renal calculi, particularly at an early age.
Cystine crystals appear as colorless, hexagonal plates and
may be thick or thin (Figs. 6–91 and 6–92). Disintegrating
forms may be seen in the presence of ammonia. They may be
difficult to differentiate from colorless uric acid crystals. Uric
acid crystals are very birefringent under polarized microscopy,
whereas only thick cystine crystals have polarizing capability.
Positive confirmation of cystine crystals is made using the
cyanide-nitroprusside test (see Chapter 8).
Cholesterol Crystals
Cholesterol crystals are rarely seen unless specimens have
been refrigerated, because the lipids remain in droplet form.
However, when observed, they have a most characteristic appearance, resembling a rectangular plate with a notch in one
or more corners (Fig. 6–93). They are associated with disorders producing lipiduria, such as the nephrotic syndrome, and
are seen in conjunction with fatty casts and oval fat bodies.
Cholesterol crystals are highly birefringent with polarized light
(Fig. 6–94).
3920_Ch06_099-146 23/01/14 10:19 AM Page 136
136
Part Two | Urinalysis
Table 6–7
Major Characteristics of Abnormal Urinary Crystals
Crystal
pH
Color/Form
Disorders
Cystine
Acid
Colorless (hexagonal plates)
Inherited
cystinuria
Cholesterol
Acid
Colorless
(notched
plates)
Nephrotic
syndrome
Leucine
Acid/neutral
Yellow (concentric circles)
Liver disease
Tyrosine
Acid/neutral
Colorless–yellow
(needles)
Liver disease
Bilirubin
Acid
Yellow
Liver disease
Sulfonamides
Acid/neutral
Varied
Infection
treatment
Radiographic dye
Acid
Colorless
(flat plates)
Radiographic
procedure
Ampicillin
Acid/neutral
Colorless
(needles)
Infection
treatment
Appearance
Radiographic Dye Crystals
Crystals of radiographic contrast media have a very similar appearance to cholesterol crystals and also are highly birefringent.
Differentiation is best made by comparison of the other
urinalysis results and the patient history. As mentioned previously, cholesterol crystals should be accompanied by other
lipid elements and heavy proteinuria. Likewise, the specific
gravity of a specimen containing radiographic contrast media
is markedly elevated when measured by refractometer.
Figure 6–91 Cystine crystals (×400).
Crystals Associated With Liver Disorders
In the presence of severe liver disorders, three rarely seen crystals may be found in the urine sediment. They are crystals of
tyrosine, leucine, and bilirubin.
3920_Ch06_099-146 23/01/14 10:19 AM Page 137
Chapter 6 | Microscopic Examination of Urine 137
Figure 6–92 Clump of cystine crystals (×400). Notice the hexagonal
shape still visible.
Figure 6–93 Cholesterol crystals. Notice the notched corners
(×400).
Figure 6–95 Tyrosine crystals in fine needle clumps (×400).
Figure 6–96 Tyrosine crystals in rosette forms (×400).
Figure 6–97 Leucine crystals (×400). Notice the concentric circles.
Figure 6–94 Cholesterol crystals under polarized light (×400).
Tyrosine crystals appear as fine colorless to yellow needles
that frequently form clumps or rosettes (Figs. 6–95 and 6–96).
They are usually seen in conjunction with leucine crystals in
specimens with positive chemical test results for bilirubin.
Tyrosine crystals may also be encountered in inherited disorders of amino acid metabolism (see Chapter 8).
Leucine crystals are yellow-brown spheres that demonstrate concentric circles and radial striations (Fig. 6–97). They
are seen less frequently than tyrosine crystals and, when present, should be accompanied by tyrosine crystals.
Bilirubin crystals are present in hepatic disorders producing large amounts of bilirubin in the urine. They appear as
clumped needles or granules with the characteristic yellow
color of bilirubin (Fig. 6–98). A positive chemical test result
for bilirubin would be expected. In disorders that produce
renal tubular damage, such as viral hepatitis, bilirubin crystals
may be found incorporated into the matrix of casts.
3920_Ch06_099-146 23/01/14 10:19 AM Page 138
138
Part Two | Urinalysis
Figure 6–98 Bilirubin crystals. Notice the classic bright yellow color
(×400).
Sulfonamide Crystals
Prior to the development of more soluble sulfonamides, the
finding of these crystals in the urine of patients being treated
for UTIs was common. Inadequate patient hydration was and
still is the primary cause of sulfonamide crystallization. The
appearance of sulfonamide crystals in fresh urine can suggest
the possibility of tubular damage if crystals are forming in the
nephron.
A variety of sulfonamide medications are currently on the
market; therefore, one can expect to encounter a variety of
crystal shapes and colors. Shapes most frequently encountered
include needles, rhombics, whetstones, sheaves of wheat, and
rosettes with colors ranging from colorless to yellow-brown
(Figs. 6–99 and 6–100). A check of the patient’s medication
history aids in the identification confirmation.
Figure 6–100 Sulfa crystals, WBCs, and bacteria seen in UTI (×400).
A
Ampicillin Crystals
Precipitation of antibiotics is not frequently encountered except for the rare observation of ampicillin crystals following
massive doses of this penicillin compound without adequate
hydration. Ampicillin crystals appear as colorless needles that
tend to form bundles following refrigeration (Fig. 6–101 A
and B). Knowledge of the patient’s history can aid in the
identification.
B
Figure 6–101 Ampicillin crystals. A. Nonrefrigerated ampicillin crystals. (×400). B. Ampicillin crystals after refrigeration (×400).
Urinary Sediment Artifacts
Figure 6–99 Sulfa crystals in rosette form (×400).
Contaminants of all types can be found in urine, particularly
in specimens collected under improper conditions or in dirty
containers. The most frequently encountered artifacts include
starch, oil droplets, air bubbles, pollen grains, fibers, and fecal
contamination. Because artifacts frequently resemble pathologic elements such as RBCs and casts, artifacts can present a
major problem to students. They are often very highly refractile
or occur in a different microscopic plane than the true sediment constituents. The reporting of artifacts is not necessary.
3920_Ch06_099-146 23/01/14 10:19 AM Page 139
Chapter 6 | Microscopic Examination of Urine 139
Starch granule contamination may occur when cornstarch is the powder used in powdered gloves. The granules
are highly refractile spheres, usually with a dimpled center
(Fig. 6–102). They resemble fat droplets when polarized, producing a Maltese cross formation. Starch granules may also
occasionally be confused with RBCs. Differentiation between
starch and pathologic elements can be made by considering
other urinalysis results, including chemical tests for blood or
protein and the presence of oval fat bodies or fatty casts.
Oil droplets and air bubbles also are highly refractile and
may resemble RBCs to inexperienced laboratory personnel. Oil
droplets may result from contamination by immersion oil or
lotions and creams and maybe seen with fecal contamination
(Fig. 6–103). Air bubbles occur when the specimen is placed
under a cover slip. The presence of these artifacts should be
considered in the context of the other urinalysis results.
Pollen grains are seasonal contaminants that appear
as spheres with a cell wall and occasional concentric circles
(Fig. 6–104). Like many artifacts, their large size may cause
them to be out of focus with true sediment constituents.
Hair and fibers from clothing and diapers may initially be
mistaken for casts (Figs. 6–105 and 6–106), though they are
usually much longer and more refractile. Examination under
polarized light can frequently differentiate between fibers and
casts (Fig. 6–107). Fibers often polarize, whereas casts, other
than fatty casts, do not polarize.
Figure 6–104 Pollen grain. Notice the concentric circles (×400).
Figure 6–105 Fiber and squamous epithelial cell (×400).
Figure 6–102 Starch granules. Notice the dimpled center (×400).
Figure 6–106 Fiber under polarized light (×100).
Figure 6–103 Fecal material and oil artifacts (×400).
Improperly collected specimens or rarely the presence of
a fistula between the intestinal and urinary tracts may produce
fecal specimen contamination. Fecal artifacts may appear as
plant and meat fibers or as brown amorphous material in a
variety of sizes and shapes (Fig. 6–108).
3920_Ch06_099-146 23/01/14 10:19 AM Page 140
140
Part Two | Urinalysis
Figure 6–107 Diaper fiber resembling a cast. Notice the refractility
(×400).
Figure 6–108 Vegetable fiber resembling waxy cast (×400).
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Mynahan, C: Evaluation of macroscopic urinalysis as a screening procedure. Lab Med 15(3):176–179, 1984.
2. Tetrault, GA: Automated reagent strip urinalysis: Utility in reducing work load of urine microscopy and culture. Lab Med
25:162–167, 1994.
3. CLSI. Urinalysis; Approved Guideline, ed 3. CLSI document
GP16–A3, Wayne, PA: Clinical and Laboratory Standards
Institute. 2009.
4. Schumann, GB, and Tebbs, RD: Comparison of slides used for
standardized routine microscopic urinalysis. J Med Technol
3(1):54–58, 1986.
5. Addis, T: The number of formed elements in the urinary sediment of normal individuals. J Clin Invest 2(5):409–415, 1926.
6. Sternheimer, R, and Malbin, R: Clinical recognition of
pyelonephritis with a new stain for urinary sediments. Am J
Med 11:312–313, 1951.
7. Microscope Techniques—Phase Contrast. Web site: http://www.
micro.magnet.fsuj.edu/primer/techniques/phase.html
8. Polarizing and Interference Contrast Microscopy. Web site:
http://www.rrz.uni-hamburg.de/biologic/b
9. Olympus Microscopy Resource Center: Specialized Microscopy
Techniques: Fluorescence. Web site: http://www.olympusmicro.
com/ primer/techniques/fluorescence/fluorhome.html. Accessed
December 19, 2006.
10. Simpson, LO: Effects of normal and abnormal urine on red cell
shape. Nephron 60(3):383–384, 1992.
11. Stapleton, FB: Morphology of urinary red blood cells: A simple
guide in localizing the site of hematuria. Pediatr Clin North Am
34(3):561–569, 1987.
12. Fassett, EG, et al: Urinary red cell morphology during exercise.
Am J Clin Pathol 285(6353):1455–1457, 1982.
13. Kohler, H, Wandel, E, and Brunch, B: Acanthocyturia: A characteristic marker for glomerular bleeding. Int Soc Nephrol
40:115–120, 1991.
14. Tomita, M, et al: A new morphological classification of urinary
erythrocytes for differential diagnosis of hematuria. Clin Nephrol
37(2):84–89, 1992.
15. Haber, MH, Lindner, LE, and Ciofalo, LN: Urinary casts after
stress. Lab Med 10(6):351–355, 1979.
16. Corwin, HL, Bray, RA, and Haber, MH: The detection and
interpretation of urinary eosinophils. Arch Pathol Lab Med
113:1256–1258, 1989.
17. Schumann, GB: Utility of urinary cytology in renal diseases.
Semin Nephrol 5(34) Sept, 1985.
18. Graber, M, et al: Bubble cells: Renal tubular cells in the urinary
sediment with characteristics of viability. J Am Soc Nephrol
1(7):999–1004, 1991.
19. Baer, DM: Tips from clinical experts: Reporting of spermatozoa
in microscopic urine exams. MLO 12:12, 1997.
20. Kumar, S, and Muchmore, A: Tamm-Horsfall protein—
Uromodulin, 1950–1990. Kidney Int 37:1395–1399, 1990.
21. Haber, MH: Urinary Sediment: A Textbook Atlas. American
Society of Clinical Pathologists, Chicago, 1981.
22. Lindner, LE, and Haber, MH: Hyaline casts in the urine:
Mechanism of formation and morphological transformations.
Am J Clin Pathol 80(3):347–352, 1983.
23. Lindner, LE, Jones, RN, and Haber, MH: A specific cast in acute
pyelonephritis. Am J Clin Pathol 73(6):809–811, 1980.
24. Haber, MH, and Lindner, LE: The surface ultrastructure of
urinary casts. Am J Clin Pathol 68(5):547–552, 1977.
25. Linder, LE, Vacca, D, and Haber, MF: Identification and
composition of types of granular urinary cast. Am J Pathol
80(3):353–358, 1983.
3920_Ch06_099-146 23/01/14 10:19 AM Page 141
Chapter 6 | Microscopic Examination of Urine 141
Study Questions
1. Macroscopic screening of urine specimens is used to:
A. Provide results as soon as possible
B. Predict the type of urinary casts present
C. Increase cost-effectiveness of urinalysis
D. Decrease the need for polarized microscopy
2. Variations in the microscopic analysis of urine include all
of the following except:
A. Preparation of the urine sediment
B. Amount of sediment analyzed
C. Method of reporting
D. Identification of formed elements
3. All of the following can cause false-negative microscopic
results except:
A. Braking the centrifuge
B. Failing to mix the specimen
C. Dilute alkaline urine
D. Using midstream clean-catch specimens
4. The two factors that determine relative centrifugal force are:
A. Radius of rotor head and rpm
B. Radius of rotor head and time of centrifugation
C. Diameter of rotor head and rpm
D. RPM and time of centrifugation
5. When using the glass slide and cover-slip method, which of
the following might be missed if the cover slip is overflowed?
A. Casts
B. RBCs
C. WBCs
D. Bacteria
6. Initial screening of the urine sediment is performed using
an objective power of:
A. 4×
B. 10×
C. 40×
D. 100×
7. Which of the following should be used to reduce light
intensity in bright-field microscopy?
A. Centering screws
B. Aperture diaphragm
C. Rheostat
D. Condenser aperture diaphragm
8. Which of the following are reported as number per lpf?
A. RBCs
B. WBCs
C. Crystals
D. Casts
9. The Sternheimer-Malbin stain is added to urine sediments
to do all of the following except:
A. Increase visibility of sediment constituents
B. Change the constituents’ refractive index
C. Decrease precipitation of crystals
D. Delineate constituent structures
10. Nuclear detail can be enhanced by:
A. Prussian blue
B. Toluidine blue
C. Acetic acid
D. Both B and C
11. Which of the following lipids is/are stained by Sudan III?
A. Cholesterol
B. Neutral fats
C. Triglycerides
D. Both B and C
12. Which of the following lipids is/are capable of polarizing
light?
A. Cholesterol
B. Neutral fats
C. Triglycerides
D. Both A and B
13. The purpose of the Hansel stain is to identify:
A. Neutrophils
B. Renal tubular cells
C. Eosinophils
D. Monocytes
14. Crenated RBCs are seen in urine that is:
A. Hyposthenuric
B. Hypersthenuric
C. Highly acidic
D. Highly alkaline
3920_Ch06_099-146 23/01/14 10:19 AM Page 142
142
Part Two | Urinalysis
15. Differentiation among RBCs, yeast, and oil droplets may
be accomplished by all of the following except:
23. Forms of transitional epithelial cells include all of the
following except:
A. Observation of budding in yeast cells
A. Spherical
B. Increased refractility of oil droplets
B. Caudate
C. Lysis of yeast cells by acetic acid
C. Convoluted
D. Lysis of RBCs by acetic acid
D. Polyhedral
16. A finding of dysmorphic RBCs is indicative of:
A. Glomerular bleeding
24. Increased transitional cells are indicative of:
A. Catheterization
B. Renal calculi
B. Malignancy
C. Traumatic injury
C. Pyelonephritis
D. Coagulation disorders
D. Both A and B
17. Leukocytes that stain pale blue with Sternheimer-Malbin
stain and exhibit brownian movement are:
25. A primary characteristic used to identify renal tubular
epithelial cells is:
A. Indicative of pyelonephritis
A. Elongated structure
B. Basophils
B. Centrally located nucleus
C. Mononuclear leukocytes
C. Spherical appearance
D. Glitter cells
D. Eccentrically located nucleus
18. Mononuclear leukocytes are sometimes mistaken for:
A. Yeast cells
B. Squamous epithelial cells
C. Pollen grains
D. Renal tubular cells
19. When pyuria is detected in a urine sediment, the slide
should be carefully checked for the presence of:
26. Following an episode of hemoglobinuria, RTE cells may
contain:
A. Bilirubin
B. Hemosiderin granules
C. Porphobilinogen
D. Myoglobin
27. The predecessor of the oval fat body is the:
A. RBCs
A. Histiocyte
B. Bacteria
B. Urothelial cell
C. Hyaline casts
C. Monocyte
D. Mucus
D. Renal tubular cell
20. Transitional epithelial cells are sloughed from the:
A. Collecting duct
B. Vagina
C. Bladder
D. Proximal convoluted tubule
21. The largest cells in the urine sediment are:
A. Squamous epithelial cells
B. Urothelial epithelial cells
C. Cuboidal epithelial cells
D. Columnar epithelial cells
22. A clinically significant squamous epithelial cell is the:
A. Cuboidal cell
B. Clue cell
C. Caudate cell
D. Columnar cell
28. A structure believed to be an oval fat body produced a
Maltese cross formation under polarized light but does not
stain with Sudan III. The structure:
A. Contains cholesterol
B. Is not an oval fat body
C. Contains neutral fats
D. Is contaminated with immersion oil
29. The finding of yeast cells in the urine is commonly associated with:
A. Cystitis
B. Diabetes mellitus
C. Pyelonephritis
D. Liver disorders
3920_Ch06_099-146 23/01/14 10:20 AM Page 143
Chapter 6 | Microscopic Examination of Urine 143
30. The primary component of urinary mucus is:
38. The presence of fatty casts is associated with:
A. Bence Jones protein
A. Nephrotic syndrome
B. Microalbumin
B. Crush injuries
C. Uromodulin
C. Diabetes mellitus
D. Orthostatic protein
D. All of the above
31. The majority of casts are formed in the:
39. Nonpathogenic granular casts contain:
A. Proximal convoluted tubules
A. Cellular lysosomes
B. Ascending loop of Henle
B. Degenerated cells
C. Distal convoluted tubules
C. Protein aggregates
D. Collecting ducts
D. Gram-positive cocci
32. Cylindruria refers to the presence of:
40. All of the following are true about waxy casts except they:
A. Cylindrical renal tubular cells
A. Represent extreme urine stasis
B. Mucus-resembling casts
B. May have a brittle consistency
C. Hyaline and waxy casts
C. Require staining to be visualized
D. All types of casts
D. Contain degenerated granules
33. A person submitting a urine specimen following a strenuous exercise routine can normally have all of the following in the sediment except:
41. Observation of broad casts represents:
A. Destruction of tubular walls
A. Hyaline casts
B. Dehydration and high fever
B. Granular casts
C. Formation in the collecting ducts
C. RBC casts
D. Both A and C
D. WBC casts
34. Prior to identifying an RBC cast, all of the following
should be observed except:
42. All of the following contribute to urinary crystals formation except:
A. Protein concentration
A. Free-floating RBCs
B. pH
B. Intact RBCs in the cast
C. Solute concentration
C. Presence of a cast matrix
D. Temperature
D. A positive reagent strip blood reaction
35. WBC casts are primarily associated with:
43. The most valuable initial aid for identifying crystals in a
urine specimen is:
A. Pyelonephritis
A. pH
B. Cystitis
B. Solubility
C. Glomerulonephritis
C. Staining
D. Viral infections
D. Polarized microscopy
36. The shape of the RTE cell associated with renal tubular
epithelial casts is primarily:
44. Crystals associated with severe liver disease include all of
the following except:
A. Elongated
A. Bilirubin
B. Cuboidal
B. Leucine
C. Round
C. Cystine
D. Columnar
D. Tyrosine
37. When observing RTE casts, the cells are primarily:
45. All of the following crystals routinely polarize except:
A. Embedded in a clear matrix
A. Uric acid
B. Embedded in a granular matrix
B. Cholesterol
C. Attached to the surface of a matrix
C. Radiographic dye
D. Stained by components of the urine filtrate
D. Cystine
3920_Ch06_099-146 23/01/14 10:20 AM Page 144
144
Part Two | Urinalysis
46. Casts and fibers can usually be differentiated using:
A. Solubility characteristics
B. Patient history
C. Polarized light
D. Fluorescent light
47. Match the following crystals seen in acidic urine with their
description/identifying characteristics:
____ Amorphous urates
1. Envelopes
____ Uric acid
2. Thin needles
____ Calcium oxalate
monohydrate
3. Yellow-brown,
whetstone
____ Calcium oxalate
dihydrate
4. Pink sediment
5. Ovoid
48. Match the following crystals seen in alkaline urine with
their description/identifying characteristics:
____ Triple phosphate
1. Yellow granules
____ Amorphous phosphate
2. Thin prisms
____ Calcium phosphate
3. “Coffin lids”
____ Ammonium biurate
4. Dumbbell shape
____ Calcium carbonate
5. White precipitate
6. Thorny apple
49. Match the following abnormal crystals with their
description/identifying characteristics:
____ Cystine
1. Bundles following
refrigeration
____ Tyrosine
2. Highly alkaline pH
____ Cholesterol
3. Bright yellow clumps
____ Leucine
4. Hexagonal plates
____ Ampicillin
5. Flat plates, high
specific gravity
____ Radiographic dye
6. Concentric circles,
radial striations
____ Bilirubin
7. Notched corners
8. Fine needles seen in
liver disease
50. Match the following types of microscopy with their
descriptions:
____ Bright-field
1. Indirect light is reflected
off the object
____ Phase
2. Objects split light into two
beams
____ Polarized
3. Low refractive index
objects may be overlooked
____ Dark-field
4. Three-dimensional images
____Fluorescent
5. Forms halo of light around
object
____Interference
6. Detects electrons
contrast
emitted from objects
7. Detects specific wavelengths
of light emitted from objects
3920_Ch06_099-146 23/01/14 10:20 AM Page 145
Chapter 6 | Microscopic Examination of Urine 145
Case Studies and Clinical Situations
1. An 85-year-old woman with diabetes and a broken hip
has been confined to bed for the past 3 months. Results
of an ancillary blood glucose test are 250 mg/dL, and her
physician orders additional blood tests and a routine
urinalysis. The urinalysis report is as follows:
COLOR: Pale yellow
KETONES: Negative
CLARITY: Hazy
BLOOD: Moderate
SP. GRAVITY: 1.020
BILIRUBIN: Negative
pH: 5.5
UROBILINOGEN: Normal
PROTEIN: Trace
NITRITE: Negative
GLUCOSE: 100 mg/dL
LEUKOCYTES: 2+
Microscopic:
20 to 25 WBCs/hpf
Many yeast cells and hyphae
a. Why are yeast infections common in patients with
diabetes mellitus?
b. With a blood glucose level of 250 mg/dL, should
glucose be present in the urine? Why or why not?
c. Is there a discrepancy between the negative nitrite and
the positive leukocyte esterase results? Explain your
answer.
d. What is the major discrepancy between the chemical
and microscopic results?
e. Considering the patient’s history, what is the most
probable cause for the discrepancy?
2. A medical technology student training in a newly renovated STAT laboratory is having difficulty performing a
microscopic urinalysis. Reagent strip testing indicates the
presence of moderate blood and leukocytes, but the student is also observing some large unusual objects resembling crystals and possible casts. The student is also
having difficulty keeping all of the constituents in focus
at the same time.
a. Why is the student having difficulty focusing?
b. What is a possible cause of the unusual microscopic
constituents?
c. Should the student be concerned about the unusual
microscopic constituents? Explain your answer.
d. What microscopy technique could be used to aid in
differentiating a cast and an artifact?
3. A prisoner sentenced to 10 years for selling illegal drugs
develops jaundice, lethargy, and hepatomegaly.
A test for hepatitis B surface antigen is positive, and the
patient is placed in the prison infirmary. When his condition appears to worsen and a low urinary output is observed, the patient is transferred to a local hospital.
Additional testing detects a superinfection with delta
hepatitis virus and decreased renal concentrating ability.
Urinalysis results are as follows:
COLOR: Amber
KETONES: Negative
CLARITY: Hazy
BLOOD: Negative
SP. GRAVITY: 1.011
BILIRUBIN: Large
pH: 7.0
UROBILINOGEN: 4.0 EU
PROTEIN: 2+
NITRITE: Negative
GLUCOSE: Negative
LEUKOCYTES: Negative
Microscopic:
2 to 4 WBCs/hpf
1 to 2 hyaline casts/lpf
1 to 3 RBCs/hpf
1 to 2 granular casts/lpf
2 to 4 bile-stained RTE
cells/hpf
0 to 1 RTE casts/lpf
0 to 1 bile-stained waxy
casts/lpf
a. Based on the urinalysis results, in what area of the
nephron is damage occurring?
b. Is this consistent with the patient’s primary diagnosis?
Explain your answer.
c. What is causing the RTE cells to be bile stained?
d. Why is the urobilinogen level elevated?
e. State a disorder in which the urobilinogen level would
be elevated, but the bilirubin result would be negative.
4. A 30-year-old woman being treated for a UTI brings a
urine specimen to the Employee Health Clinic at 4:00 p.m.
The nurse on duty tells her that the specimen will be refrigerated and tested by the technologist the next morning.
The technologist has difficulty interpreting the color of the
reagent strip tests and reports only the following results:
COLOR: Amber
CLARITY: Slightly cloudy
Microscopic:
3 to 5 RBCs/hpf
8 to 10 WBCs/hpf
Moderate bacteria
Moderate colorless crystals appearing in bundles
a. What could have caused the technologist to have
difficulty interpreting the reagent strip results?
b. Could this specimen produce a yellow foam when
shaken?
c. What could the technologist do to aid in the identification of the crystals?
d. What is the probable identification of the colorless
crystals?
3920_Ch06_099-146 23/01/14 10:20 AM Page 146
146
Part Two | Urinalysis
5. A 2-year-old left unattended in the garage for 5 minutes
is suspected of ingesting antifreeze (ethylene glycol). The
urinalysis has a pH of 6.0 and is negative on the chemical
examination. Two distinct forms of crystals are observed
in the microscopic examination.
a. What type of crystals would you expect to be present?
b. What is the other form of this crystal?
c. Describe the two forms.
d. Which form would you expect to be predominant?
6. A female patient comes to the outpatient clinic with
symptoms of UTI. She brings a urine specimen with her.
Results of the routine analysis performed on this specimen are as follows:
COLOR: Yellow
KETONES: Negative
CLARITY: Hazy
BLOOD: Small
SP. GRAVITY: 1.015
BILIRUBIN: Negative
pH: 9.0
UROBILINOGEN: Normal
PROTEIN: Negative
NITRITE: Negative
GLUCOSE: Negative
LEUKOCYTE: 2+
Microscopic:
1 to 3 RBCs/hpf
Heavy bacteria
8 to 10 WBCs/hpf
Moderate squamous
epithelial cells
a. What discrepancies are present between the chemical
and microscopic test results?
b. State a reason for the discrepancies.
c. Identify a chemical result in the urinalysis that confirms your reason for the discrepancies.
d. What course of action should the laboratory take to
obtain accurate results for this patient?
7. A high school student is taken to the emergency room
with a broken leg that occurred during a football game.
The urinalysis results are as follows:
COLOR: Dark yellow
KETONES: Negative
CLARITY: Hazy
BLOOD: Moderate
SP. GRAVITY: 1.030
BILIRUBIN: Negative
pH: 5.5
UROBILINOGEN: Normal
PROTEIN: 2+
NITRITE: Negative
GLUCOSE: Negative
LEUKOCYTE: Negative
Microscopic:
0 to 3 WBCs/hpf
0 to 4 hyaline casts/lpf
0 to 3 granular casts/lpf
Few squamous epithelial cells
a. Are these results of clinical significance?
b. Explain the discrepancy between the chemical and
microscopic blood results.
c. What is the probable cause of the granular casts?
8. As supervisor of the urinalysis section, you are reviewing
results. State why or why not each of the following results
would concern you.
a. The presence of waxy casts and a negative protein in
urine from a 6–month-old girl
b. Increased transitional epithelial cells in a specimen
obtained following cystoscopy
c. Tyrosine crystals in a specimen with a negative
bilirubin test result
d. Cystine crystals in a specimen from a patient diagnosed with gout
e. Cholesterol crystals in urine with a specific gravity
greater than 1.040
f. Trichomonas vaginalis in a male urine specimen
g. Amorphous urates and calcium carbonate crystals in
a specimen with a pH of 7.0
3920_Ch07_147-162 23/01/14 10:21 AM Page 147
CHAPTER
7
Renal Disease
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
7-1 Differentiate among renal diseases of glomerular,
tubular, interstitial, and vascular origin.
7-2 Describe the processes by which immunologic damage
is caused to the glomerular basement membrane.
7-3 Define glomerulonephritis.
7-4 Describe the characteristic clinical symptoms,
etiology, and urinalysis findings in acute poststreptococcal and rapidly progressive glomerulonephritis,
Goodpasture syndrome, Wegener granulomatosis,
and Henoch-Schönlein purpura.
7-5 Name three renal disorders that also involve acute
respiratory symptoms.
7-9 Compare and contrast the nephrotic syndrome and
minimal change disease with regard to laboratory
results and course of disease.
7-10 State two causes of acute tubular necrosis.
7-11 Name the urinary sediment constituent most
diagnostic of renal tubular damage.
7-12 Describe Fanconi syndrome, Alport syndrome,
uromodulin-associated renal disease, and renal
glucosuria.
7-13 Differentiate between diabetic nephropathy and
nephrogenic diabetes insipidus.
7-6 Differentiate between membranous and membranoproliferative glomerulonephritis.
7-14 Compare and contrast the urinalysis results in patients
with cystitis, pyelonephritis, and acute interstitial
nephritis.
7-7 Discuss the clinical course and significant
laboratory results associated with immunoglobulin
A nephropathy.
7-15 Differentiate among causes of laboratory results
associated with prerenal, renal, and postrenal acute
renal failure.
7-8 Relate laboratory results associated with the nephrotic
syndrome to the disease process.
7-16 Discuss the formation of renal calculi, composition of
renal calculi, and patient management techniques.
KEY TERMS
Acute interstitial nephritis (AIN)
Focal segmental glomerulosclerosis
(FSGS)
Pyelonephritis
Antiglomerular basement
membrane antibody (ANCA)
Glomerulonephritis
Uromodulin-associated kidney
disease
Antineutrophilic cytoplasmic
antibody
Lithiasis
Cystitis
Nephrotic syndrome
Acute tubular necrosis (ATN)
IgA nephropathy
Lithotripsy
Tubulointerstitial disease
3920_Ch07_147-162 23/01/14 10:21 AM Page 148
148
Part Two | Urinalysis
Disorders throughout the body can affect renal function and
produce abnormalities in the urinalysis. Considering that
the major function of the kidneys is filtration of the blood to
remove waste products, it becomes evident that the kidneys
are consistently exposed to potentially damaging substances.
Renal disease is often classified as being glomerular, tubular, or interstitial, based on the area of the kidney primarily
affected. In this chapter, we will cover the most commonly
encountered disorders in relation to the affected areas of the
kidney. Basic knowledge of these disorders can be helpful when
analyzing the results of a routine urinalysis.
Glomerular Disorders
Most glomerular disorders result from immunologic disorders
throughout the body, including the kidney. Immune complexes
formed as a result of immunologic reactions and increased
serum immunoglobulins, such as immunoglobulin A (IgA),
circulate in the bloodstream and are deposited on the glomerular membranes. Components of the immune system, including
complement, neutrophils, lymphocytes, monocytes, and cytokines, are then attracted to the area, producing changes and
damage to the membranes. Depending on the immune system
mediators involved, damage may consist of cellular infiltration
or proliferation resulting in thickening of the glomerular basement membrane, and complement-mediated damage to the
capillaries and basement membrane.
Nonimmunologic causes of glomerular damage include
exposure to chemicals and toxins that also affect the tubules,
disruption of the electrical membrane charges as occurs in the
nephrotic syndrome, deposition of amyloid material from systemic disorders that may involve chronic inflammation and
acute-phase reactants, and the basement membrane thickening
associated with diabetic nephropathy.
Glomerulonephritis
The term glomerulonephritis refers to a sterile, inflammatory process that affects the glomerulus and
is associated with the finding of blood, protein, and
casts in the urine.1 A variety of types of glomerulonephritis exist, and the condition also may progress from one
form to another (i.e., rapidly progressive glomerular nephritis
to chronic glomerulonephritis to the nephrotic syndrome and
eventual renal failure).
Acute Poststreptococcal Glomerulonephritis
As its name implies, acute glomerulonephritis (AGN) is a
disease marked by the sudden onset of symptoms consistent
with damage to the glomerular membrane. These may include
fever, edema (most noticeably around the eyes), fatigue,
hypertension, oliguria, and hematuria. Symptoms usually
occur in children and young adults following respiratory infections caused by certain strains of group A streptococcus
that contain M protein in the cell wall. During the course of
the infection, these nephrogenic strains of streptococci form
immune complexes with their corresponding circulating
antibodies and become deposited on the glomerular membranes. The accompanying inflammatory reaction affects
glomerular function.
In most cases, successful management of the secondary
complications (hypertension and electrolyte imbalance) until
the immune complexes have been cleared from the blood and
the inflammation subsides, results in no permanent kidney
damage.
Primary urinalysis findings include marked hematuria,
proteinuria, and oliguria, accompanied by red blood cell (RBC)
casts, dysmorphic RBCs, hyaline and granular casts, and white
blood cells (WBCs). As toxicity to the glomerular membrane
subsides, urinalysis results return to normal, with the possible
exception of microscopic hematuria that lasts until the membrane damage has been repaired. Blood urea nitrogen (BUN)
may be elevated during the acute stages but, like the urinalysis,
returns to normal. Demonstration of positive anti–group A
streptococcal enzyme tests provides evidence that the disease
is of streptococcal origin.
Since the development of rapid anti–group A streptococcal
enzyme tests that can be performed in a physician’s office, urgent care facility, or emergency department, the incidence of
acute post-streptococcal glomerulonephritis has declined.
Rapidly Progressive (Crescentic) Glomerulonephritis
A more serious form of acute glomerular disease is called rapidly
progressive (or crescentic) glomerulonephritis and has a much
poorer prognosis, often terminating in renal failure. Symptoms
are initiated by deposition of immune complexes in the glomerulus, often as a complication of another form of glomerulonephritis or an immune systemic disorder such as systemic lupus
erythematosus (SLE). Damage by macrophages to the capillary
walls releases cells and plasma into Bowman’s space, and the
production of crescentic formations containing macrophages, fibroblasts, and polymerized fibrin, causes permanent damage to
the capillary tufts.
Initial laboratory results are similar to acute glomerulonephritis but become more abnormal as the disease progresses, including markedly elevated protein levels and very
low glomerular filtration rates. Some forms may demonstrate
increased fibrin degradation products, cryoglobulins, and the
deposition of IgA immune complexes in the glomerulus.2
Goodpasture Syndrome
Morphologic changes to the glomeruli resembling those in rapidly progressive glomerular nephritis are seen in conjunction
with the autoimmune disorder termed Goodpasture syndrome.
A cytotoxic autoantibody can appear against the glomerular
and alveolar basement membranes after viral respiratory infections. Attachment of this autoantibody to the basement membrane, followed by complement activation, produces the
capillary destruction. Referred to as antiglomerular basement
membrane antibody, the autoantibody can be detected in
patient serum.
Initial pulmonary complaints are hemoptysis and dyspnea, followed by the development of hematuria. Urinalysis
3920_Ch07_147-162 23/01/14 10:21 AM Page 149
Chapter 7 | Renal Disease
results include proteinuria, hematuria, and the presence of
RBC casts. Progression to chronic glomerulonephritis and endstage renal failure is common.
Wegener Granulomatosis
Wegener granulomatosis causes a granuloma-producing inflammation of the small blood vessels primarily of the kidney
and respiratory system. Key to the diagnosis of Wegener
granulomatosis is the demonstration of antineutrophilic
cytoplasmic antibody (ANCA) in the patient’s serum.3 Binding of these autoantibodies to the neutrophils located in the
vascular walls may initiate the immune response and the
resulting granuloma formation. Patients usually present first
with pulmonary symptoms and later develop renal involvement, including hematuria, proteinuria, RBC casts, and
elevated serum creatinine and BUN.
Testing for ANCA includes incubating the patient’s serum
with either ethanol or formalin/formaldehyde-fixed neutrophils
and examining the preparation using indirect immunofixation
to detect the serum antibodies attached to the neutrophils. If
the neutrophils are fixed in ethanol, the antibodies form a perinuclear pattern called p-ANCA. When the neutrophils are
fixed with formalin/formaldehyde, the pattern is granular
throughout the cytoplasm called c-ANCA.4
Henoch-Schönlein Purpura
Henoch-Schönlein purpura disease occurs primarily in children after upper respiratory infections. As its name implies,
initial symptoms include the appearance of raised, red patches
on the skin. Respiratory and gastrointestinal symptoms, including blood in the sputum and stools, may be present. Renal
involvement is the most serious complication of the disorder
and may range from mild to heavy proteinuria and hematuria
with RBC casts. Complete recovery with normal renal function
is seen in more than 50% of patients. In other patients, progression to a more serious form of glomerulonephritis and
renal failure may occur. Urinalysis and renal function assessment should be used to monitor patients following recovery
from the original symptoms.
Membranous Glomerulonephritis
The predominant characteristic of membranous glomerulonephritis is a pronounced thickening of the glomerular
basement membrane resulting from the deposition of immunoglobulin G immune complexes. Disorders associated
with membranous glomerulonephritis development include
systemic lupus erythematosus, Sjögren syndrome, secondary
syphilis, hepatitis B, gold and mercury treatments, and malignancy. Many cases of unknown etiology have been reported. As a rule, the disease progresses slowly, with possible
remission; however, nephrotic syndrome symptoms frequently develop.5 There may also be a tendency toward
thrombosis.
Laboratory findings include microscopic hematuria and
elevated urine protein excretion that may reach concentrations
similar to those in the nephrotic syndrome. Demonstration of
149
one of the secondary disorders through blood tests can aid in
the diagnosis.
Membranoproliferative Glomerulonephritis
Membranoproliferative glomerulonephritis (MPGN) is marked
by two different alterations in the cellularity of the glomerulus
and peripheral capillaries. Type 1 displays increased cellularity
in the subendothelial cells of the mesangium (interstitial area
of Bowman’s capsule), causing thickening of the capillary walls,
whereas type 2 displays extremely dense deposits in the
glomerular basement membrane. Many of the patients are children, and the disease has a poor prognosis: type 1 patients
progress to the nephrotic syndrome and type 2 patients experience symptoms of chronic glomerulonephritis. The laboratory findings vary, but hematuria, proteinuria, and decreased
serum complement levels are usual findings. There appears to
be an association with autoimmune disorders, infections, and
malignancies.6
Chronic Glomerulonephritis
Depending on the amount and duration of the damage to the glomerulus in the previously discussed
glomerular disorders, progression to chronic glomerulonephritis and end-stage renal disease may occur.
Gradually worsening symptoms include fatigue, anemia, hypertension, edema, and oliguria.
Examination of the urine reveals hematuria, proteinuria,
glucosuria as a result of tubular dysfunction, and many varieties of casts, including broad casts. A markedly decreased
glomerular filtration rate is present in conjunction with increased BUN and creatinine levels and electrolyte imbalance.
Immunoglobulin A Nephropathy
Also known as Berger disease, IgA nephropathy, in which
immune complexes containing IgA are deposited on the
glomerular membrane, is the most common cause of glomerulonephritis. Patients have increased serum levels of IgA, which
may be a result of a mucosal infection. The disorder is most
frequently seen in children and young adults.
Patients usually present with an episode of macroscopic
hematuria following an infection or strenuous exercise. Recovery
from the macroscopic hematuria is spontaneous; however,
asymptomatic microhematuria and elevated serum levels of IgA
remain.7 Except for periodic episodes of macroscopic hematuria,
a patient with the disorder may remain essentially asymptomatic
for 20 years or more; however, there is a gradual progression to
chronic glomerulonephritis and end-stage renal disease.
Nephrotic Syndrome
The nephrotic syndrome is marked by massive proteinuria (greater than 3.5 g/day), low levels of serum
albumin, high levels of serum lipids, and pronounced edema.1 Acute onset of the disorder can
occur in instances of circulatory disruption producing systemic shock that decrease the pressure and flow of blood to
the kidney. Progression to the nephrotic syndrome may also
3920_Ch07_147-162 23/01/14 10:21 AM Page 150
150
Part Two | Urinalysis
occur as a complication of the previously discussed forms of
glomerulonephritis.
Increased permeability of the glomerular membrane is
attributed to damage to the shield of negativity and the
podocytes that produces a less tightly connected barrier. Such
damage facilitates passage of high-molecular-weight proteins
and lipids and negatively charged albumin into the urine. Albumin is the primary protein depleted from the circulation.
The ensuing hypoalbuminemia appears to stimulate increased
lipid production by the liver. The lower oncotic pressure in the
capillaries resulting from the depletion of plasma albumin increases fluid loss into the interstitial spaces, which, accompanied by sodium retention, produces the edema. Depletion of
immunoglobulins and coagulation factors places patients at an
increased risk of infection and coagulation disorders. Both tubular and glomerular damage occurs, and the nephrotic syndrome may progress to chronic renal failure.
Urinalysis observations include marked proteinuria; urinary fat droplets; oval fat bodies; renal tubular epithelial (RTE)
cells; epithelial, fatty, and waxy casts; and microscopic hematuria. Absorption of the lipid-containing proteins by the RTE
cells followed by cellular sloughing produces the characteristic
oval fat bodies seen in the sediment examination.
Minimal Change Disease
As the name implies, minimal change disease (also known as
lipid nephrosis) produces little cellular change in the
glomerulus, except for some damage to the podocytes and
the shield of negativity, allowing for increased protein filtration. Patients are usually children who present with edema,
heavy proteinuria, transient hematuria, and normal BUN and
creatinine results. Although the etiology is unknown at this
time, allergic reactions, recent immunization, and possession
of the human leukocyte antigen-B12 (HLA-B12) antigen have
been associated with this disease. The disorder responds well
to corticosteroids, and prognosis is generally good, with
frequent complete remissions.8
Focal Segmental Glomerulosclerosis
In contrast to the previously discussed disorders, focal segmental glomerulosclerosis (FSGS) affects only certain
Table 7–1
numbers and areas of glomeruli, and the others remain normal. Symptoms may be similar to the nephrotic syndrome
and minimal change disease owing to damaged podocytes.
Immune deposits, primarily immunoglobulin M and C3, are
a frequent finding and can be seen in undamaged glomeruli.
FSGS is often seen in association with abuse of heroin and
analgesics and with AIDS. Moderate to heavy proteinuria and
microscopic hematuria are the most consistent urinalysis
findings.
Laboratory testing and clinical information for the
glomerular disorders are summarized in Tables 7–1 and 7–2.
Tubular Disorders
Disorders affecting the renal tubules include those in which
tubular function is disrupted as a result of actual damage to
the tubules and those in which a metabolic or hereditary disorder affects the intricate functions of the tubules.
Acute Tubular Necrosis
The primary disorder associated with damage to the
renal tubules is acute tubular necrosis (ATN).
Damage to the RTE cells may be produced by decreased blood flow that causes a lack of oxygen presentation to the tubules (ischemia) or the presence of toxic
substances in the urinary filtrate.
Disorders causing ischemic ATN include shock, trauma
(such as crushing injuries), and surgical procedures. “Shock”
is a general term indicating a severe condition that decreases
the flow of blood throughout the body. Examples of conditions
that may cause shock are cardiac failures, sepsis involving toxigenic bacteria, anaphylaxis, massive hemorrhage, and contact
with high-voltage electricity.
Exposure to a variety of nephrotoxic agents can damage
and affect the function of the RTE cells. Substances include
aminoglycoside antibiotics, the antifungal agent amphotericin
B, cyclosporine, radiographic dye, organic solvents such as ethylene glycol, heavy metals, and toxic mushrooms. As discussed
in Chapter 5, filtration of large amounts of hemoglobin and
myoglobin is also nephrotoxic.
Laboratory Testing in Glomerular Disorders
Disorder
Primary Urinalysis Result
Other Significant Tests
Acute glomerulonephritis
Macroscopic hematuria
Anti–group A streptococcal
enzyme tests
Rapidly progressive glomerulonephritis
Proteinuria
RBC casts
Granular casts
Macroscopic hematuria
Proteinuria
RBC casts
BUN
Creatinine
eGFR
3920_Ch07_147-162 23/01/14 10:21 AM Page 151
Chapter 7 | Renal Disease
Table 7–1
Laboratory Testing in Glomerular Disorders—cont’d
Disorder
Primary Urinalysis Result
Other Significant Tests
Goodpasture syndrome
Macroscopic hematuria
Antiglomerular basement
membrane antibody
Wegener granulomatosis
Proteinuria
RBC casts
Macroscopic hematuria
Henoch-Schönlein purpura
Membranous glomerulonephritis
Membranoproliferative glomerulonephritis
Chronic glomerulonephritis
IgA nephropathy (early stages)
IgA nephropathy (late stages)
Nephrotic syndrome
Minimal change disease
Focal segmental glomerulosclerosis
Alport syndrome (early stages)
(late stages)
Diabetic nephropathy (late stages)
Proteinuria
RBC casts
Macroscopic hematuria
Proteinuria
RBC casts
Microscopic hematuria
Proteinuria
Hematuria
Proteinuria
Hematuria
Proteinuria
Glucosuria
Cellular and granular casts
Waxy and broad casts
Macroscopic or microscopic
hematuria
See Chronic glomerulonephritis
Heavy proteinuria
Microscopic hematuria
Renal tubular cells
Oval fat bodies
Fat droplets
Fatty and waxy casts
Heavy proteinuria
Transient hematuria
Fat droplets
Proteinuria
Microscopic hematuria
Macroscopic or microscopic
hematuria
See Nephrotic syndrome
Microalbuminuria
See Chronic glomerulonephritis
Antineutrophilic peripheral or
cytoplasmic antibody
Stool occult blood
Antinuclear antibody
Hepatitis B surface antigen
Fluorescent treponemal
antibody-absorption test
(FTA-ABS)
Serum complement levels
BUN
Serum creatinine
eGFR
Electrolytes
Serum IgA
Serum albumin
Cholesterol
Triglycerides
Serum albumin
Cholesterol
Triglycerides
Drugs of abuse
HIV tests
Genetic testing
Blood glucose
151
3920_Ch07_147-162 23/01/14 10:21 AM Page 152
152
Part Two | Urinalysis
Table 7–2
Clinical Information Associated With Glomerular Disorders
Disorder
Etiology
Clinical Course
Acute glomerulonephritis
Deposition of immune complexes, formed in
conjunction with group A Streptococcus infection, on the glomerular membranes
Deposition of immune complexes from systemic immune disorders on the glomerular membrane
Attachment of a cytotoxic antibody formed
during viral respiratory infections to
glomerular and alveolar basement
membranes
Rapid onset of hematuria and
edema, permanent renal damage
seldom occurs
Rapid onset with glomerular damage and possible progression to
end-stage renal failure
Hemoptysis and dyspnea followed
by hematuria
Rapidly progressive
glomerulonephritis
Goodpasture syndrome
Wegener granulomatosis
Antineutrophilic cytoplasmic autoantibody
binds to neutrophils in vascular walls
producing damage to small vessels in the
lungs and glomerulus
Henoch-Schönlein
purpura
Occurs primarily in children following viral
respiratory infections; a decrease in
platelets disrupts vascular integrity
Membranous
glomerulonephritis
Thickening of the glomerular membrane following IgG immune complex deposition
associated with systemic disorders
Cellular proliferation affecting the capillary
walls or the glomerular basement membrane, possibly immune-mediated
Marked decrease in renal function resulting
from glomerular damage precipitated by
other renal disorders
Deposition of IgA on the glomerular membrane resulting from increased levels of
serum IgA
Membranoproliferative
glomerulonephritis
Chronic glomerulonephritis
IgA nephropathy
Nephrotic syndrome
Disruption of the shield of negativity and
damage to the tightly fitting podocyte barrier resulting in massive loss of protein
and lipids
Minimal change disease
Disruption of the podocytes occurring primarily in children following allergic reactions and immunizations
Disruption of podocytes in certain areas of
glomeruli associated with heroin and analgesic abuse and AIDS
Genetic disorder showing lamellated and
thinning glomerular basement membrane
Focal segmental
glomerulosclerosis
Alport syndrome
Possible progression to end-stage
renal failure
Pulmonary symptoms including hemoptysis develop first followed
by renal involvement and possible progression to end-stage renal
failure
Initial appearance of purpura
followed by blood in sputum
and stools and eventual renal
involvement
Complete recovery is common, but
may progress to renal failure
Slow progression to the nephrotic
syndrome or possible remission
Slow progression to chronic
glomerulonephritis or nephrotic
syndrome
Noticeable decrease in renal function progressing to renal failure
Recurrent macroscopic hematuria
following exercise with slow progression to chronic glomerulonephritis
Acute onset following systemic
shock
Gradual progression from other
glomerular disorders and then to
renal failure
Frequent complete remission following corticosteroid treatment
May resemble nephrotic syndrome
or minimal change disease
Slow progression to nephrotic syndrome and end-stage renal disease
3920_Ch07_147-162 23/01/14 10:21 AM Page 153
Chapter 7 | Renal Disease
The disease course of ATN varies. It may present as an
acute complication of an ischemic event or more gradually during exposure to toxic agents. Correcting the ischemia, removing the toxic substances, and effectively managing the
accompanying symptoms of acute renal failure frequently result in a complete recovery.
Urinalysis findings include mild proteinuria, microscopic
hematuria, and, most noticeably, the presence of RTE cells and
RTE cell casts containing tubular fragments consisting of three
or more cells. As a result of the tubular damage, a variety of
other casts may be present, including hyaline, granular, waxy,
and broad.
Hereditary and Metabolic Tubular
Disorders
Disorders affecting tubular function may be caused by systemic
conditions that affect or override the tubular reabsorptive maximum (Tm) for particular substances normally reabsorbed by
the tubules or by failure to inherit a gene or genes required for
tubular reabsorption.
Fanconi Syndrome
The disorder most frequently associated with tubular dysfunction is Fanconi syndrome. The syndrome consists of a generalized failure of tubular reabsorption in the proximal
convoluted tubule. Therefore, substances most noticeably affected include glucose, amino acids, phosphorous, sodium,
potassium, bicarbonate, and water. Tubular reabsorption may
be affected by dysfunction of the transport of filtered substances across the tubular membranes, disruption of cellular
energy needed for transport, or changes in the tubular membrane permeability.
Fanconi syndrome may be inherited in association with
cystinosis and Hartnup disease (see Chapter 8), acquired
through exposure to toxic agents, including heavy metals and
outdated tetracycline, or seen as a complication of multiple
myeloma and renal transplant.
Urinalysis findings include glycosuria with a normal blood
glucose and possible mild proteinuria. Urinary pH can be very
low due to the failure to reabsorb bicarbonate.
Alport Syndrome
Alport syndrome is an inherited disorder of collagen production affecting the glomerular basement membrane. The syndrome can be inherited as a sex-linked or autosomal genetic
disorder. Males inheriting the X-linked gene are more severely
affected than females inheriting the autosomal gene. During
respiratory infections, males younger than age 6 years may exhibit macroscopic hematuria and continue to exhibit microscopic hematuria. Abnormalities in hearing and vision may also
develop.
The glomerular basement membrane has a lamellated appearance with areas of thinning. No evidence of glomerular antibodies is present. The prognosis ranges from mild symptoms
to persistent hematuria and renal insufficiency in later life to
the nephrotic syndrome and end-stage renal disease.
153
Uromodulin-Associated Kidney Disease
Uromodulin is a glycoprotein and is the only protein produced
by the kidney. It is produced by the proximal and distal convoluted tubules. Although it is not measured by routine laboratory methods, research has shown that it is the primary
protein found in normal urine.
Uromodulin-associated kidney disease is primarily an
inherited disorder caused by an autosomal mutation in the
gene that produces uromodulin. The mutation causes a decrease in the production of normal uromodulin that is replaced
by the abnormal form. The abnormal uromodulin is still produced by the tubular cells and accumulates in these cells, resulting in their destruction, which leads to the need for renal
monitoring and eventual renal transplantation. 9
The mutation also causes an increase in serum uric acid,
resulting in persons developing gout as early as the teenage
years before the onset of detectable renal disease.9
Diabetic Nephropathy
Diabetic nephropathy is currently the most common cause of
end-stage renal disease. Damage to the glomerular membrane
occurs not only as a result of glomerular membrane thickening
but also because of the increased proliferation of mesangial cells
and increased deposition of cellular and noncellular material
within the glomerular matrix, resulting in accumulation of solid
substances around the capillary tufts. This glomerular damage
is believed to be associated with deposition of glycosylated proteins resulting from poorly controlled blood glucose levels. The
vascular structure of the glomerulus also develops sclerosis.
As discussed in Chapter 5, early monitoring of persons diagnosed with diabetes mellitus for the presence of microalbuminuria is important to detect the onset of diabetic
nephropathy. Modification of diet and strict control of hypertension can decrease the progression of the renal disease.
Nephrogenic Diabetes Insipidus
As discussed in Chapter 3, urine concentration is regulated in
the distal convoluted tubules and the collecting ducts in response to antidiuretic hormone (ADH) produced by the hypothalamus. When the action of ADH is disrupted either by
the inability of the renal tubules to respond to ADH (nephrogenic diabetes insipidus [DI]) or failure of the hypothalamus
to produce ADH (neurogenic DI), excessive amounts of urine
are excreted. Differentiation between the two types of DI is covered in Chapter 3.
Nephrogenic DI can be inherited as a sex-linked recessive
gene or acquired from medications, including lithium and amphotericin B. It also may be seen as a complication of polycystic
kidney disease and sickle cell anemia.
TECHNICAL TIP As discussed in Chapter 6, uromodulin
forms the matrix of urinary casts seen in many renal disorders. The defective gene is not associated with other renal
disorders.
3920_Ch07_147-162 23/01/14 10:21 AM Page 154
154
Part Two | Urinalysis
Urinalysis findings associated with DI are low specific
gravity, pale yellow color, and possible false-negative results
for chemical tests.
Renal Glycosuria
In contrast to Fanconi syndrome, which exhibits a generalized
failure to reabsorb substances from the glomerular filtrate, renal
glucosuria affects only the reabsorption of glucose. The disorder is inherited as an autosomal recessive trait.
In inherited renal glucosuria either the number of glucose
transporters in the tubules is decreased or the affinity of the
transporters for glucose is decreased. Under normal conditions
glucose is not present in the urine unless the blood glucose
level reaches the maximal tubular reabsorption capacity for
glucose (TMG), which is 160 to 180 mg/dL. Patients with renal
glycosuria have increased urine glucose concentrations with
normal blood glucose concentrations.
Table 7–3
Laboratory testing and clinical information for the hereditary and metabolic disorders are summarized in Tables 7–3
and 7–4.
Interstitial Disorders
Considering the close proximity between the renal
tubules and the renal interstitium, disorders affecting
the interstitium also affect the tubules, resulting in
the condition commonly called tubulointerstitial
disease. Most of these disorders involve infections and inflammatory conditions.
The most common renal disease is a urinary tract infection (UTI). Infection may involve the lower urinary tract
(urethra and bladder) or the upper urinary tract (renal
pelvis, tubules, and interstitium). Most frequently encountered is infection of the bladder (cystitis), which can
Laboratory Testing in Metabolic and Hereditary Tubular Disorders
Disorder
Primary Urinalysis Results
Other Significant Tests
Acute tubular necrosis
Microscopic hematuria
Proteinuria
Renal tubular epithelial cells
Renal tubular epithelial cell casts
Hyaline, granular, waxy, broad casts
Glucosuria
Possible cystine crystals
Renal tubular epithelial cells
Hemoglobin
Hematocrit
Fanconi syndrome
Uromodulin-associated kidney
disease (early stages)
Late stages
Nephrogenic diabetes insipidus
Renal glucosuria
Table 7–4
Cardiac enzymes
Serum and urine electrolytes
Amino acid chromatography
Serum uric acid
See chronic glomerulonephritis
Low specific gravity, polyuria
Glucosuria
ADH testing
Blood glucose
Clinical Information Associated With Metabolic and Tubular Disorders
Disorder
Etiology
Clinical Course
Acute tubular necrosis
Damage to renal tubular cells caused by
ischemia or toxic agents
Fanconi syndrome
Inherited in association with cystinosis and
Hartnup disease or acquired through
exposure to toxic agents
Inherited defect in the production of normal
uromodulin by the renal tubules and
increased uric acid causing gout
Inherited defect of tubular response to ADH
or acquired from medications
Inherited autosomal recessive trait
Acute onset of renal dysfunction usually
resolved when underlying cause is
corrected
Generalized defect in renal tubular reabsorption requiring supportive therapy
Uromodulin-associated
kidney disease
Nephrogenic diabetes
insipidus
Renal glucosuria
Continual monitoring of renal function
for progression to renal failure and
possible kidney transplantation
Requires supportive therapy to prevent
dehydration
Benign disorder
3920_Ch07_147-162 23/01/14 10:21 AM Page 155
Chapter 7 | Renal Disease
progress to a more serious upper UTI if left untreated. Cystitis is seen more often in women and children, who present
with symptoms of urinary frequency and burning. Urinalysis
reveals the presence of numerous WBCs and bacteria, often
accompanied by mild proteinuria and hematuria and an
increased pH.
Acute Pyelonephritis
Infection of the upper urinary tract, including both the
tubules and interstitium, is termed pyelonephritis and can
occur in both acute and chronic forms. Acute pyelonephritis
most frequently occurs as a result of ascending movement
of bacteria from a lower UTI into the renal tubules and interstitium. Patients present with rapid onset of symptoms,
including urinary frequency, burning on urination, and
lower back pain,
The ascending movement of bacteria from the bladder is
enhanced with conditions that interfere with the downward
flow of urine from the ureters to the bladder or the incomplete
emptying of the bladder during urination. These include obstructions such as renal calculi, pregnancy, and reflux of urine
from the bladder back into the ureters (vesicoureteral reflux).
With appropriate antibiotic therapy and removal of any underlying conditions, acute pyelonephritis can be resolved without
permanent damage to the tubules.
Urinalysis results are similar to those seen in cystitis, including numerous leukocytes and bacteria with mild proteinuria and hematuria. The additional finding of WBC casts,
signifying infection within the tubules, is of primary diagnostic value for both acute and chronic pyelonephritis. Sediments
also should be carefully observed for the presence of bacterial
casts.
Chronic Pyelonephritis
As its name implies, chronic pyelonephritis is a serious disorder that can result in permanent damage to the renal
tubules and possible progression to chronic renal failure.
Congenital urinary structural defects producing reflux
nephropathy are the most frequent cause of chronic
pyelonephritis. The structural abnormalities may cause reflux
between the bladder and ureters or within the renal pelvis,
affecting emptying of the collecting ducts. Owing to its congenital origin, chronic pyelonephritis is often diagnosed in
children and may not be suspected until tubular damage has
become advanced.
Urinalysis results are similar to those seen in acute
pyelonephritis, particularly in the early stages. As the disease
progresses, a variety of granular, waxy, and broad casts are present, accompanied by increased proteinuria and hematuria, and
renal concentration is decreased.
TECHNICAL TIP The presence of WBC casts is significant
for differentiating between cystitis and pyelonephritis.
155
Acute Interstitial Nephritis
Acute interstitial nephritis (AIN) is marked by
inflammation of the renal interstitium followed by
inflammation of the renal tubules. Patients present
with a rapid onset of symptoms relating to renal dysfunction, including oliguria, edema, decreased renal concentrating ability, and a possible decrease in the glomerular
filtration rate. Fever and the presence of a skin rash are
frequent initial symptoms.
AIN is primarily associated with an allergic reaction to medications that occurs within the renal interstitium, possibly caused
by the medication binding to the interstitial protein. Symptoms
tend to develop approximately 2 weeks following administration
of medication. Medications commonly associated with AIN include penicillin, methicillin, ampicillin, cephalosporins, sulfonamides, NSAIDs, and thiazide diuretics. Discontinuing the
offending medication and administering steroids to control the
inflammation frequently results in a return to normal renal function. However, supportive renal dialysis may be required to
maintain patients until the inflammation subsides.
Urinalysis results include hematuria, possibly macroscopic, mild to moderate proteinuria, numerous WBCs, and
WBC casts without bacteria. Differential leukocyte staining for
the presence of increased eosinophils may be useful to confirm
the diagnosis.10
Laboratory testing and clinical information for the interstitial disorders is summarized in Tables 7–5 and 7–6.
Renal Failure
Renal failure exists in both acute and chronic forms.
As discussed in conjunction with many of the previous disorders, this may be a gradual progression from
the original disorder to chronic renal failure or endstage renal disease. The progression to end-stage renal disease is
characterized by a marked decrease in the glomerular filtration
rate (less than 25 mL/min); steadily rising serum BUN and creatinine values (azotemia); electrolyte imbalance; lack of renal
concentrating ability producing an isosthenuric urine; proteinuria; renal glycosuria; and an abundance of granular, waxy, and
broad casts, often referred to as a telescoped urine sediment.
Acute renal failure (ARF), in contrast to chronic renal
failure, exhibits a sudden loss of renal function and is frequently reversible. Primary causes of ARF include a sudden
decrease in blood flow to the kidney (prerenal), acute
glomerular and tubular disease (renal), and renal calculi or
tumor obstructions (postrenal). As can be seen from the
variety of causes (Table 7–7), patients may present with
many different symptoms relating to the particular disorder
involved; however, a decreased glomerular filtration rate,
oliguria, edema, and azotemia are general characteristics.
Similar to clinical symptoms, urinalysis findings are
varied, but because they relate to the primary cause of the ARF,
they can be diagnostically valuable. For example, the presence
of RTE cells and casts suggests ATN of prerenal origin; RBCs indicate glomerular injury; WBC casts with or without bacteria
3920_Ch07_147-162 23/01/14 10:21 AM Page 156
156
Part Two | Urinalysis
Table 7–5
Laboratory Results in Interstitial Disorders
Disorder
Primary Urinalysis Results
Other Significant Tests
Cystitis
Leukocyturia
Bacteriuria
Microscopic hematuria
Mild proteinuria
Increased pH
Leukocyturia
Bacteriuria
WBC casts
Bacterial casts
Microscopic hematuria
Proteinuria
Leukocyturia
Bacteriuria
WBC casts
Urine culture
Acute pyelonephritis
Chronic pyelonephritis
Bacterial casts
Granular, waxy, broad casts
Hematuria
Proteinuria
Hematuria
Proteinuria
Leukocyturia
WBC casts
Acute interstitial nephritis
Table 7–6
Urine culture
Urine culture
BUN
Creatinine
eGFR
Urine eosinophils
BUN
Creatinine
eGFR
Clinical Information Associated With Interstitial Disorders
Disorder
Etiology
Clinical Course
Cystitis
Ascending bacterial infection of the bladder
Acute pyelonephritis
Infection of the renal tubules and
interstitium related to interference of
urine flow to the bladder, reflux of
urine from the bladder, and untreated
cystitis
Recurrent infection of the renal tubules
and interstitium caused by structural
abnormalities affecting the flow of urine
Acute onset of urinary frequency and burning
resolved with antibiotics
Acute onset of urinary frequency, burning, and
lower back pain resolved with antibiotics
Chronic pyelonephritis
Acute interstitial
nephritis
Allergic inflammation of the renal interstitium in response to certain medications
Frequently diagnosed in children; requires
correction of the underlying structural
defect
Possible progression to renal failure
Acute onset of renal dysfunction often accompanied by a skin rash
Resolves following discontinuation of medication and treatment with corticosteroids
3920_Ch07_147-162 23/01/14 10:21 AM Page 157
Chapter 7 | Renal Disease
Table 7–7
Causes of Acute Renal Failure
Prerenal
Decreased blood pressure/cardiac output
Hemorrhage
Burns
Surgery
Septicemia
Renal
Acute glomerulonephritis
Acute tubular necrosis
Acute pyelonephritis
Acute interstitial nephritis
Postrenal
Renal calculi
Tumors
performed chemically, but examination using x-ray crystallography provides a more comprehensive analysis. Approximately
75% of the renal calculi are composed of calcium oxalate or calcium phosphate. Magnesium ammonium phosphate (struvite),
uric acid, and cystine are the other primary calculi constituents.
Calcium calculi are frequently associated with metabolic calcium
and phosphate disorders and occasionally diet. Magnesium
ammonium phosphate calculi are frequently accompanied by
urinary infections involving urea-splitting bacteria. The urine
pH is often higher than 7.0. Uric acid calculi may be associated
with increased intake of foods with high purine content and with
uromodulin-associated kidney disease. The urine pH is acidic.
Most cystine calculi are seen in conjunction with hereditary
disorders of cystine metabolism (see Chapter 8). Patient management techniques include maintaining the urine at a pH
incompatible with crystallization of the particular chemicals,
maintaining adequate hydration to lower chemical concentration, and suggesting possible dietary restrictions.
Urine specimens from patients suspected of passing or
being in the process of passing renal calculi are frequently received in the laboratory. The presence of microscopic hematuria resulting from irritation to the tissues by the moving
calculus is the primary urinalysis finding.
indicate interstitial infection or inflammation of renal origin;
and postrenal obstruction may show normal- and abnormalappearing urothelial cells possibly associated with malignancy.
Renal Lithiasis
Renal calculi (kidney stones) may form in the calyces and pelvis
of the kidney, ureters, and bladder. In renal lithiasis, the calculi
vary in size from barely visible to large, staghorn calculi resembling the shape of the renal pelvis and smooth, round bladder
stones with diameters of 2 or more inches. Small calculi may
be passed in the urine, subjecting the patient to severe pain radiating from the lower back to the legs. Larger stones cannot
be passed and may not be detected until patients develop symptoms of urinary obstruction. Lithotripsy, a procedure using
high-energy shock waves, can be used to break stones located
in the upper urinary tract into pieces that can then be passed
in the urine. Stones can also be removed surgically.
Conditions favoring the formation of renal calculi are
similar to those favoring formation of urinary crystals,
including pH, chemical concentration, and urinary stasis.
Numerous correlation studies between the presence of crystalluria and renal calculi formation have been conducted
with varying results. The finding of clumps of crystals in
freshly voided urine suggests that conditions may be right
for calculus formation. However, owing to the difference in
conditions that affect the urine within the body and in a
specimen container, little importance can be placed on the
role of crystals in predicting calculi formation. Increased
crystalluria has been noted during the summer months in
persons known to form renal calculi.11
Analysis of the chemical composition of renal calculi plays
an important role in patient management. Analysis can be
157
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Forland, M (ed): Nephrology. Medical Examination Publishing,
New York, 1983.
2. Couser, WG: Rapidly progressive glomerulonephritis. In
Jacobson, HR, et al: Principles and Practice of Nephrology.
BC Decker, Philadelphia, 1991.
3. Kallenberg, CG, Mulder, AH, and Tervaert, JW: Antineutrophil cytoplasmic autoantibodies: A still-growing class
of autoantibodies in inflammatory disorders. Am J Med
93(6):675–682, 1992.
4. Frasier, LL, and Hoag, KA: Differential diagnosis of Wegener’s
granulomatosis from other small vessel vasculitides. LabMed
38(7): 437–439, 2007.
5. Wasserstein, AG: Membranous glomerulonephritis. In
Jacobson, HR, et al: Principles and Practice of Nephrology.
BC Decker, Philadelphia, 1991.
6. Donadio, JV: Membranoproliferative glomerulonephritis. In
Jacobson, HR, et al: Principles and Practice of Nephrology.
BC Decker, Philadelphia, 1991.
7. Bricker, NS, and Kirschenbaum, MA: The Kidney: Diagnosis
and Management. John Wiley, New York, 1984
8. Sherbotle, JR, and Hayes, JR: Idiopathic nephrotic syndrome:
Minimal change disease and focal segmental glomerulosclerosis.
In Jacobson, HR, et al: Principles and Practice of Nephrology.
BC Decker, Philadelphia, 1991.
9. Bleyer, AJ, Zivna, M, and Kmoch, S: Uromodulin associated
kidney disease. Nephron Clin Prac 118(1): 2011.
10. Bennett, WM, Elzinga, LW, and Porter, GA: Tubulointerstitial
disease and toxic nephropathy. In Brenner, BM, and Rector, FC:
The Kidney: Physiology and Pathophysiology. WB Saunders,
Philadelphia, 1991.
11. Hallson, PC, and Rose, GA: Seasonal variations in urinary
crystals. Br J Urol 49(4): 277–284, 1977.
3920_Ch07_147-162 23/01/14 10:21 AM Page 158
158
Part Two | Urinalysis
Study Questions
1. Most glomerular disorders are caused by:
A. Sudden drops in blood pressure
B. Immunologic disorders
C. Exposure to toxic substances
D. Bacterial infections
2. Dysmorphic RBC casts would be a significant finding with
all of the following except:
A. Goodpasture syndrome
B. Acute glomerulonephritis
C. Chronic pyelonephritis
D. Henoch-Schönlein purpura
3. Occasional episodes of macroscopic hematuria over periods
of 20 or more years are seen with:
A. Crescentic glomerulonephritis
B. IgA nephropathy
C. Nephrotic syndrome
D. Wegener granulomatosis
4. Antiglomerular basement membrane antibody is seen with:
A. Wegener granulomatosis
B. IgA nephropathy
C. Goodpasture syndrome
D. Diabetic nephropathy
5. Antineutrophilic cytoplasmic antibody is diagnostic for:
A. IgA nephropathy
B. Wegener granulomatosis
C. Henoch-Schönlein purpura
D. Goodpasture syndrome
6. Respiratory and renal symptoms are associated with all of
the following except:
A. IgA nephropathy
B. Wegener granulomatosis
C. Henoch-Schönlein purpura
D. Goodpasture syndrome
7. The presence of fatty casts is associated with all of the following except:
A. Nephrotic syndrome
B. Focal segmental glomerulosclerosis
C. Nephrogenic diabetes insipidus
D. Minimal change disease
8. The highest levels of proteinuria are seen with:
A. Alport syndrome
B. Diabetic nephropathy
C. IgA nephropathy
D. Nephrotic syndrome
9. Ischemia frequently produces:
A. Acute renal tubular necrosis
B. Minimal change disorder
C. Renal glycosuria
D. Goodpasture’s syndrome
10. A disorder associated with polyuria and low specific
gravity is:
A. Renal glucosuria
B. Minimal change disease
C. Nephrogenic diabetes insipidus
D. Focal segmental glomerulosclerosis
11. An inherited disorder producing a generalized defect in
tubular reabsorption is:
A. Alport syndrome
B. Acute interstitial nephritis
C. Fanconi syndrome
D. Renal glycosuria
12. A teenage boy who develops gout in his big toe and has a
high serum uric acid should be monitored for:
A. Fanconi syndrome
B. Renal calculi
C. Uromodulin-associated kidney disease
D. Chronic interstitial nephritis
13. The only protein produced by the kidney is:
A. Albumin
B. Uromodulin
C. Uroprotein
D. Globulin
14. The presence of renal tubular epithelial cells and casts is
an indication of:
A. Acute interstitial nephritis
B. Chronic glomerulonephritis
C. Minimal change disease
D. Acute tubular necrosis
3920_Ch07_147-162 23/01/14 10:21 AM Page 159
Chapter 7 | Renal Disease
15. Differentiation between cystitis and pyelonephritis is aided
by the presence of:
A. WBC casts
B. RBC casts
C. Bacteria
D. Granular casts
16. The presence of WBCs and WBC casts with no bacteria is
indicative of:
A. Chronic pyelonephritis
B. Acute tubular necrosis
C. Acute interstitial nephritis
D. Both B and C
17. End-stage renal disease is characterized by all of the
following except:
A. Hypersthenuria
B. Isosthenuria
C. Azotemia
D. Electrolyte imbalance
159
18. Prerenal acute renal failure could be caused by:
A. Massive hemorrhage
B. Acute tubular necrosis
C. Acute interstitial nephritis
D. Malignant tumors
19. The most common composition of renal calculi is:
A. Calcium oxalate
B. Magnesium ammonium phosphate
C. Cystine
D. Uric acid
20. Urinalysis on a patient with severe back pain being evaluated for renal calculi would be most beneficial if it
showed:
A. Heavy proteinuria
B. Low specific gravity
C. Uric acid crystals
D. Microscopic hematuria
Case Studies and Clinical Situations
1. A 14-year-old boy who has recently recovered from a sore
throat develops edema and hematuria. Significant laboratory results include a BUN of 30 mg/dL (normal 8 to
23 mg/dL) and a positive group A streptococcal antibody
test. Results of a urinalysis are as follows:
Color: Red
Ketones: Negative
Clarity: Cloudy
Blood: Large
Sp. gravity: 1.020
Bilirubin: Negative
pH: 5.0
Urobilinogen: Normal
Protein: 3+
Nitrite: Negative
Glucose: Negative
Leukocyte: Trace
Microscopic:
100 RBCs/hpf—many dysmorphic forms
5–8 WBCs/hpf
0–2 granular casts/lpf
0–1 RBC casts/lpf
a. What disorder do these results and history
indicate?
b. What specific characteristic was present in the
organism causing the sore throat?
c. What is the significance of the dysmorphic RBCs?
d. Are the WBCs significant? Why or why not?
e. What is the expected prognosis of this patient?
f. If the above urinalysis results were seen in a 5-year-old
boy who has developed a red, patchy rash following
recovery from a respiratory infection, what disorder
would you suspect?
2. B.J. is a seriously ill 40-year-old man with a history of
several episodes of macroscopic hematuria in the past
20 years. The episodes were associated with exercise or
stress. Until recently the macroscopic hematuria had
spontaneously reverted to asymptomatic microscopic
hematuria. Significant laboratory results include a BUN of
80 mg/dL (normal 8 to 23 mg/dL), serum creatinine of
4.5 mg/dL (normal 0.6 to 1.2 mg/dL), creatinine clearance
of 20 mL/min (normal 107 to 139 mL/min), serum calcium
of 8.0 mg/dL (normal 9.2 to 11.0 mg/dL), serum phosphorus of 6.0 mg/dL (normal 2.3 to 4.7 mg/dL), and an elevated level of serum IgA. Results of a routine urinalysis
are as follows:
Color: Red
Ketones: Negative
Clarity: Slightly cloudy
Blood: Large
Sp. gravity: 1.010
Bilirubin: Negative
pH: 6.5
Urobilinogen: Normal
Protein: 300 mg/dL
Nitrite: Negative
Glucose: 250 mg/dL
Leukocyte: Trace
3920_Ch07_147-162 23/01/14 10:21 AM Page 160
160
Part Two | Urinalysis
Microscopic:
>100 RBCs/hpf
2–4 hyaline casts/lpf
8–10 WBCs/hpf
1–5 granular casts/lpf
0–2 waxy casts/lpf
0–2 broad waxy
a. What specific disease do the patient’s laboratory
results and history suggest?
b. Which laboratory result is most helpful in diagnosing
this disease?
c. What additional diagnosis does his current condition
suggest?
d. What is the significance of the positive result for urine
glucose?
e. Is the specific gravity significant? Why or why not?
f. What is the significance of the waxy casts?
3. A 45-year-old woman is recovering from injuries received
in an automobile accident that resulted in her being taken
to the emergency department with severe hypotension.
She develops massive edema. Significant laboratory results include a BUN of 30 mg/dL (normal 8 to 23 mg/dL),
cholesterol of 400 mg/dL (normal 150 to 240 mg/dL),
triglycerides of 840 mg/dL (normal 10 to 190 mg/dL),
serum protein of 4.5 mg/dL (normal 6.0 to 7.8 mg/dL),
albumin of 2.0 mg/dL (normal 3.2 to 4.5 mg/dL), and
a total urine protein of 3.8 g/d (normal 100 mg/d).
Urinalysis results are as follows:
Color: Yellow
Ketones: Negative
Clarity: Cloudy
Blood: Moderate
Sp. gravity: 1.015
Bilirubin: Negative
pH: 6.0
Urobilinogen: Normal
Protein: 4+
Nitrite: Negative
Glucose: Negative
Leukocyte: Negative
Microscopic:
15–20 RBCs/hpf
Moderate free fat droplets
0–2 granular casts/lpf
0–5 WBCs/hpf
Moderate cholesterol
0–2 fatty casts/lpf
crystals
0–2 oval fat bodies/hpf
a. What renal disorder do these results suggest?
b. How does the patient’s history relate to this
disorder?
c. What physiologic mechanism accounts for the
massive proteinuria?
d. What is the relationship of the proteinuria to the
edema?
e. What mechanism produces the oval fat bodies?
4. A routinely active 4-year-old boy becomes increasingly
less active after receiving several preschool immunizations. His pediatrician observes noticeable puffiness
around the eyes. A blood test shows normal BUN
and creatinine results and markedly decreased total
protein and albumin values. Urinalysis results are as
follows:
Color: Yellow
Ketones: Negative
Clarity: Hazy
Blood: Small
Sp. gravity: 1.018
Bilirubin: Negative
pH: 6.5
Urobilinogen: Normal
Protein: 4+
Nitrite: Negative
Glucose: Negative
Leukocyte: Negative
Microscopic:
10–15 RBCs/hpf
0–1 hyaline casts/lpf
0–4 WBCs/hpf
0–2 granular casts/lpf
Moderate fat droplets
0–1 oval fat bodies/hpf
a. What disorder do the patient history, physical
appearance, and laboratory results suggest?
b. What other renal disorders produce similar
urinalysis results?
c. What is the expected prognosis for this patient?
5. A 32-year-old construction worker experiences
respiratory difficulty followed by the appearance
of blood-streaked sputum. He delays visiting a
physician until symptoms of extreme fatigue and
red urine are present. A chest radiograph shows pulmonary infiltration, and sputum culture is negative
for pathogens. Blood test results indicate anemia,
increased BUN and creatinine, and the presence
of antiglomerular basement membrane antibody.
Urinalysis results are as follows:
Color: Red
Ketones: Negative
Clarity: Cloudy
Blood: Large
Sp. gravity: 1.015
Bilirubin: Negative
ph: 6.0
Urobilinogen: Normal
Protein: 3+
Nitrite: Negative
Glucose: Negative
Leukocyte: Trace
Microscopic:
100 RBCs/hpf
0–3 hyaline casts/lpf
10–15 WBCs/hpf
0–3 granular casts/lpf
0–2 RBCs casts/lpf
a. What disorder do the laboratory results suggest?
b. How is this disorder affecting the glomerulus?
c. If the antiglomerular membrane antibody test is negative, what disorder might be considered?
d. What is the diagnostic test for this disorder?
e. By what mechanism does this disorder affect the
glomerulus?
6. A 25-year-old pregnant woman comes to the outpatient
clinic with symptoms of lower back pain, urinary
frequency, and a burning sensation when voiding.
3920_Ch07_147-162 23/01/14 10:21 AM Page 161
Chapter 7 | Renal Disease
Her pregnancy has been normal up to this time. She
is given a sterile container and asked to collect a
midstream clean-catch urine specimen. Routine
urinalysis results are as follows:
Color: Pale yellow
Ketones: Negative
Clarity: Hazy
Blood: Small
Sp. gravity: 1.005
Bilirubin: Negative
pH: 8.0
Urobilinogen: Normal
Protein: Trace
Nitrite: Positive
Glucose: Negative
Leukocyte: 2+
Microscopic:
6–10 RBCs/hpf
Heavy bacteria
40–50 WBCs/hpf
Moderate squamous
epithelial cells
a. What is the most probable diagnosis for this
patient?
b. What is the correlation between the color and the
specific gravity?
c. What is the significance of the blood and protein
tests?
d. Is this specimen suitable for the appearance of
glitter cells? Explain your answer.
e. What other population is at a high risk for
developing this condition?
f. What disorder might develop if this disorder is not
treated?
7. A 10-year-old patient with a history of recurrent UTIs is
admitted to the hospital for diagnostic tests. Initial urinalysis results are as follows:
Color: Yellow
Ketone: Negative
Clarity: Cloudy
Blood: Small
Sp. gravity: 1.025
Bilirubin: Negative
pH: 8.0
Urobilinogen: Normal
Protein: 2+
Nitrite: Positive
Glucose: Negative
Leukocyte: 2+
Microscopic:
6–10 RBCs/hpf
0–2 WBC casts/lpf Many
bacteria
>100 WBCs/hpf
0–1 bacterial casts/lpf with
clumps
A repeat urinalysis a day later has the following results:
Color: Yellow
Ketones: Negative
clarity: Cloudy
Blood: Small
Sp. gravity: >1.035
bilirubin: Negative
pH: 7.5
Urobilinogen: Normal
Protein: 2+
Nitrite: Positive
Glucose: Negative
Leukocyte: 2+
161
Microscopic:
6–10 RBCs/hpf
Many bacteria
0–2 WBC casts/lpf
>100 WBCs/hpf
Moderate birefringent,
0–1 bacterial casts/lpf
flat crystals
a. What diagnostic procedure was performed on the patient that could account for the differences in the two
urinalysis results?
b. Considering the patient’s age and history, what is the
most probable diagnosis?
c. What microscopic constituent is most helpful to this
diagnosis?
d. What is the most probable cause of this disorder?
e. How can the presence of the bacterial cast be
confirmed?
f. What is the most probable source of the crystals
present in the sediment?
g. Without surgical intervention, what is the patient’s
prognosis?
8. A 35-year-old patient being treated for a sinus infection
with methicillin develops fever, a skin rash, and edema.
Urinalysis results are as follows:
Color: Dark yellow
Ketones: Negative
Clarity: Cloudy
Blood: Moderate
Sp. gravity: 1.012
Bilirubin: Negative
pH: 6.0
Urobilinogen: Normal
Protein: 3+
Nitrite: Negative
Glucose: Negative
Leukocyte: 2+
Microscopic:
20–30 RBCs/hpf
1–2 WBC casts/lpf
>100 WBCs/hpf
1–2 granular casts/lpf
After receiving the urinalysis report, the physician
orders a test for urinary eosinophils. The urinary
eosinophil result is 10%.
a. Is the urinary eosinophil result normal or
abnormal?
b. What is the probable diagnosis for this patient?
c. Discuss the significance of the increased WBCs
and WBC casts in the absence of bacteria.
d. How can this condition be corrected?
9. Following surgery to correct a massive hemorrhage, a
55-year-old patient exhibits oliguria and edema. Blood
test results indicate increasing azotemia and electrolyte
imbalance. The glomerular filtration rate is 20 mL/min.
Urinalysis results are as follows:
Color: Yellow
Ketones: Negative
Clarity: Cloudy
Blood: Moderate
Sp. gravity: 1.010
Bilirubin: Negative
3920_Ch07_147-162 23/01/14 10:21 AM Page 162
162
Part Two | Urinalysis
pH: 7.0
Protein: 3+
Glucose: 2+
Microscopic:
50–60 RBCs/hpf
3–6 WBCs/hpf
3–4 RTE cells/hpf
a.
b.
c.
d.
e.
Urobilinogen: Normal
Nitrite: Negative
Leukocyte: Negative
2–3 granular casts/lpf
2–3 RTE cell casts/lpf
0–1 waxy casts/lpf
0–1 broad granular casts/lpf
What diagnosis do the patient’s history and laboratory results suggest?
What is the most probable cause of the patient’s
disorder? Is this considered to be of prerenal, renal,
or postrenal origin?
What is the significance of the specific gravity
result?
What is the significance of the RTE cells?
State two possible reasons for the presence of the
broad casts.
10. A 40-year-old man develops severe back and abdominal pain after dinner. The pain subsides during the
night but recurs in the morning, and he visits his
family physician. Results of a complete blood count
and an amylase are normal. Results of a routine
urinalysis are as follows:
Color: Dark yellow
Ketones: Negative
Clarity: Hazy
Blood: Moderate
Sp. gravity: 1.030
Bilirubin: Negative
pH: 5.0
Urobilinogen: Normal
Protein: Trace
Nitrite: Negative
Glucose: Negative
Leukocytes: Negative
Microscopic
15–20 RBCs/hpf
0–2 WBCs/hpf
Few squamous epithelial cells
a. What condition could these urinalysis results and
the patient’s symptoms represent?
b. What would account for the crenated RBCs?
c. Is there a correlation between the urine color and
specific gravity and the patient’s symptoms?
d. Based on the primary substance that causes this
condition, what type of crystals might have been
present?
e. What changes will the patient be advised to make
in his lifestyle to prevent future occurrences?
3920_Ch08_163-179 23/01/14 10:22 AM Page 163
CHAPTER
8
Urine Screening for
Metabolic Disorders
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
8-1 Explain abnormal accumulation of metabolites in the
urine in terms of overflow and renal disorders.
8-10 State the significance of increased urinary
5-hydroxyindoleacetic acid.
8-2 Discuss the importance of and the MS/MS testing
methods for newborn screening.
8-11 Differentiate between cystinuria and cystinosis, including the differences found during analysis of the
urine and the disease processes.
8-3 Name the metabolic defect in phenylketonuria, and
describe the clinical manifestations it produces.
8-4 State three causes of tyrosyluria.
8-5 Name the abnormal urinary substance present in
alkaptonuria, and explain how its presence may be
suspected.
8-6 Discuss the appearance and significance of urine that
contains melanin.
8-7 Describe a basic laboratory observation that has relevance in maple syrup urine disease.
8-8 Discuss the significance of ketonuria in a newborn.
8-12 Describe the components in the heme synthesis pathway, including the primary specimens used for their
analysis, and explain the cause and clinical significance of major porphyrias and the appearance of
porphyrins in urine.
8-13 Define mucopolysaccharides, and name three syndromes in which they are involved.
8-14 State the significance of increased uric acid crystals
in newborns’ urine.
8-15 Explain the reason for performing tests for urinaryreducing substances on all newborns.
8-9 Differentiate between the presence of urinary indican
owing to intestinal disorders and Hartnup disease.
KEY TERMS
Alkaptonuria
Inborn error of metabolism (IEM)
Mucopolysaccharidoses
Cystinosis
Indicanuria
Organic acidemias
Cystinuria
Lesch-Nyhan disease
Phenylketonuria (PKU)
Galactosuria
Maple syrup urine disease (MSUD)
Porphyrinuria
Hartnup disease
Melanuria
Tyrosyluria
Homocystinuria
Melituria
3920_Ch08_163-179 23/01/14 10:22 AM Page 164
164
Part Two | Urinalysis
As discussed in previous chapters, many of the abnormal results obtained in the routine urinalysis are related to metabolic
rather than renal disease. Urine as an end product of body metabolism may contain additional abnormal substances not
tested for by routine urinalysis. Often these substances can be
detected or monitored by additional screening tests that can
also be performed in the urinalysis laboratory. Positive screening tests can then be followed up with more sophisticated procedures performed in other sections of the laboratory.
The need to perform additional tests may be detected by
the observations of alert laboratory personnel when performing
the routine analysis or from observations of abnormal specimen color and odor by nursing staff and patients (Table 8–1).
In other instances, clinical symptoms and family histories are
the deciding factors.
Overflow Versus Renal
Disorders
The appearance of abnormal metabolic substances in the urine
can be caused by a variety of disorders that can generally be
grouped into two categories, termed the overflow type and the
Table 8–1
Abnormal Metabolic Constituents or
Conditions Detected in the Routine
Urinalysis
Color
Odor
Crystals
Homogentisic acid
Melanin
Phenylketonuria
Maple syrup urine
disease
Isovaleric acidemia
Cystinuria
Cystinosis
Homocystinuria
Cystine
Leucine
Indican
Porphyrins
Table 8–2
Tyrosine
LeschNyhan
disease
renal type. Overflow disorders result from disruption of a normal metabolic pathway that causes increased plasma concentrations of the nonmetabolized substances. These chemicals
either override the reabsorption ability of the renal tubules or
are not normally reabsorbed from the filtrate because they are
present in only minute amounts. Abnormal accumulations of
the renal type are caused by malfunctions in the tubular reabsorption mechanism, as discussed in Chapter 7.
The most frequently encountered abnormalities are associated with metabolic disturbances that produce urinary overflow
of substances involved in protein, fat, and carbohydrate metabolism. This is understandable when one considers the vast number of enzymes used in the metabolic pathways of proteins, fats,
and carbohydrates and the fact that their function is essential for
complete metabolism. Disruption of enzyme function can be
caused by failure to inherit the gene to produce a particular
enzyme, referred to as an inborn error of metabolism (IEM),1
or by organ malfunction from disease or toxic reactions. The
most frequently encountered abnormal urinary metabolites are
summarized in Table 8–2, and their appearance is classified according to functional defect. Table 8–2 also includes substances
and conditions that are covered in this chapter.
Newborn Screening Tests
Many of the urine tests discussed in this chapter traditionally
were performed primarily to detect and monitor newborns for
IEMs. In recent years the screening of newborns has increased
to include more sensitive detection methods and ever-increasing
levels of state-mandated tests for IEMs. Many states currently
require testing for as many as 30 or more metabolic disorders.2
As discussed later in this chapter, because many of these
disorders cause the buildup of unmetabolized toxic food
ingredients, it is important that the defects be detected early
in life. Levels of these substances are elevated more rapidly in
blood than urine. Therefore, blood collected by infant heel
puncture is initially tested. Testing for many substances is
now performed using tandem mass spectrophotometry
Major Disorders of Protein and Carbohydrate Metabolism Associated
With Abnormal Urinary Constituents, Classified by Functional Defect
Overflow Inherited
Metabolic
Renal
Phenylketonuria
Tyrosinemia
Alkaptonuria
Maple syrup urine disease
Organic acidemias
Cystinosis
Porphyria
Mucopolysaccharidoses
Galactosemia
Lesch-Nyhan disease
Infantile tyrosinemia
Melanuria
Indicanuria
5-Hydroxyindoleacetic acid
Porphyria
Hartnup disease
Cystinuria
3920_Ch08_163-179 23/01/14 10:22 AM Page 165
Chapter 8 | Urine Screening for Metabolic Disorders
(MS/MS). MS/MS is capable of screening the infant blood
sample for specific substances associated with particular
IEMs. Figure 8–1 shows the standard form collected for testing using MS/MS. Methods for specific gene testing are also
rapidly being developed.
165
Amino Acid Disorders
The amino acid disorders with urinary screening tests include
phenylketonuria (PKU), tyrosyluria, alkaptonuria, melanuria,
maple syrup urine disease, organic acidemias, indicanuria,
cystinuria, and cystinosis.
Phenylalanine-Tyrosine Disorders
Major inherited disorders include PKU, tyrosyluria, and
alkaptonuria. Metabolic defects cause overproduction of
melanin. The relationship of these varied disorders is illustrated in Figure 8–2.
Phenylketonuria
Figure 8–1 Specimen collection form for MS/MS newborn screening
test.
The most well known of the aminoacidurias, PKU is estimated
to occur in 1 of every 10,000 to 20,000 births and, if undetected, results in severe mental retardation. It was first identified
in Norway by Ivan Følling in 1934, when a mother with other
mentally retarded children reported a peculiar mousy odor to
her child’s urine. Analysis of the urine showed increased
Normal Metabolism
Metabolic Disorders
Phenylalanine
Phenylketonuria
Enzymes
Phenylalanine hydroxylase
Tyrosine
Phenylpyruvic acid
Tyrosinemia
Type 2
Tyrosyluria
p-Hydroxyphenylpyruvic acid
p-Hydroxyphenyllactic acid
Tyrosinemia
Type 3
Alkaptonuria
Homogentisic
acid
Tyrosinemia Type 1b
Tyrosinemia
Type 1
Tyrosinemia Type 1a
Tyrosine
aminotransferase
Melanin
Thyroxine
Epinephrine
Normal Byproducts
p-Hydroxyphenylpyruvic
acid
p-Hydroxyphenylpyruvate
oxidase
Homogentisic acid
Homogentisic acid
oxidase
Maleylacetoacetic
acid
Maleylacetoacetic
acid isomerase
Fumarylacetoacetic
acid
Fumarylacetoacetic
acid hydrolase
Fumaric acid and
acetoacetic acid
Figure 8–2 Phenylalanine and tyrosine metabolic pathway including the normal pathway (blue), enzymes (yellow), and disorders caused by
failure to inherit particular enzymes (green).
3920_Ch08_163-179 23/01/14 10:22 AM Page 166
166
Part Two | Urinalysis
amounts of the keto acids, including phenylpyruvate. As shown
in Figure 8–2, this occurs when the normal conversion of
phenylalanine to tyrosine is disrupted. Interruption of the pathway also produces children with fair complexions—even in
dark-skinned families—owing to the decreased production of
tyrosine and its pigmentation metabolite melanin.
PKU is caused by failure to inherit the gene to produce the
enzyme phenylalanine hydroxylase. The gene is inherited as an
autosomal recessive trait with no noticeable characteristics or
defects exhibited by heterozygous carriers. Fortunately, screening tests are available for early detection of the abnormality, and
all states have laws that require the screening of newborns for
PKU.2 Once discovered, dietary changes that eliminate phenylalanine, a major constituent of milk, from the infant’s diet can
prevent excessive buildup of serum phenylalanine, thereby
avoiding damage to the child’s mental capabilities. As the child
matures, alternative pathways of phenylalanine metabolism develop, and dietary restrictions can be eased. Many products that
contain large amounts of phenylalanine, such as aspartame,
now features warning labels for people with PKU.
The initial screening for PKU does not come under the auspices of the urinalysis laboratory, because increased blood levels
of phenylalanine must, of course, occur before urinary excretion
of phenylpyruvic acid, which may take 2 to 6 weeks. State laws
require that blood be collected after 24 hours after birth and before the newborn leaves the hospital. The increasing tendency to
release newborns from the hospital as early as 24 hours after birth
has caused concern about the ability to detect increased phenylalanine levels at that early stage. Studies have shown that in many
cases phenylalanine can be detected as early as 4 hours after birth
and, if the cutoff level for normal results is lowered from 4 mg/dL
to 2 mg/dL, the presence of PKU should be detected. Tests may
need to be repeated during an early visit to the pediatrician. More
girls than boys escape detection of PKU during early tests because
of slower rises in blood phenylalanine levels.1
Urine testing using ferric chloride may be used as a followup test to ensure proper dietary control in previously diagnosed
cases and as a means of monitoring the dietary intake of pregnant women known to lack phenylalanine hydroxylase.
Urine tests for phenylpyruvic acid are based on the ferric
chloride reaction performed by tube test. The addition of ferric
chloride to urine containing phenylpyruvic acid produces a
permanent blue-green color (see Procedure 8-1).
of tyrosine metabolism may result from either inherited or metabolic defects. Also, because two reactions are directly involved
in the metabolism of tyrosine, the urine may contain excess tyrosine or its degradation products, p-hydroxyphenylpyruvic
acid and p-hydroxyphenyllactic acid.
Most frequently seen is a transitory tyrosinemia in premature infants, which is caused by underdevelopment of the liver
function required to produce the enzymes necessary to complete the tyrosine metabolism.
Acquired severe liver disease also produces tyrosyluria resembling that of the transitory newborn variety and, of course,
is a more serious condition. In both instances, rarely seen tyrosine and leucine crystals may be observed during microscopic examination of the urine sediment.
Hereditary disorders in which enzymes required in the
metabolic pathway are not produced present serious and often
fatal conditions that result in both liver and renal tubular disease producing a generalized aminoaciduria. Based on the enzymes affected, the hereditary disorders can be classified into
three types, all producing tyrosylemia and tyrosyluria.
As shown in Figure 8–2, type 1 is caused by the deficiency
of the enzyme fumarylacetoacetate hydrolase (FAH). Type 1
produces a generalized renal tubular disorder and progressive
liver failure in infants soon after birth. Type 2 tyrosinemia is
caused by lack of the enzyme tyrosine aminotransferase. Persons develop corneal erosion and lesions on the palms, fingers,
and soles of the feet believed to be caused by crystallization of
tyrosine in the cells. Type 3 tyrosinemia is caused by lack of
the enzyme p-hydroxyphenylpyruvic acid dioxygenase. This
can result in mental retardation if dietary restrictions of phenylalanine and tyrosine are not implemented.
Screening tests using MS/MS are available for tyrosinemia
types 1, 2, and 3. See Procedure 8-2 for urine testing for tyrosyluria using nitroso-naphthol.
Melanuria
The previous discussion focused on the major phenylalaninetyrosine metabolic pathway illustrated in Figure 8–2; however, as also shown in Figure 8–2 and is the case with many
amino acids, a second metabolic pathway also exists for
tyrosine. This pathway is responsible for the production of
Tyrosyluria
PROCEDURE 8-2
The accumulation of excess tyrosine in the plasma (tyrosinemia)
producing urinary overflow may be due to several causes and
is not well categorized. As can be seen in Table 8–2, disorders
Nitroso-Naphthol Test for Tyrosine
1. Place five drops of urine in a tube.
2. Add 1 mL of 2.63N nitric acid.
3. Add one drop of 21.5% sodium nitrite.
4. Add 0.1 mL 1-nitroso-2-napthol.
5. Mix.
6. Wait 5 minutes.
7. Observe for an orange-red color, indicating tyrosine
metabolites.
PROCEDURE 8-1
Ferric Chloride Tube Test
1. Place 1 mL of urine in a tube.
2. Slowly add five drops of 10% ferric chloride.
3. Observe color for a permanent blue-green color.
3920_Ch08_163-179 23/01/14 10:23 AM Page 167
Chapter 8 | Urine Screening for Metabolic Disorders
167
melanin, thyroxine, epinephrine, protein, and tyrosine sulfate. Of these substances, the major concern of the urinalysis
laboratory is melanin, the pigment responsible for the dark
color of hair, skin, and eyes. Deficient production of melanin
results in albinism.
Increased urinary melanin darkens the urine. The darkening appears after the urine is exposed to air. Elevated urinary
melanin is a serious finding that indicates proliferation of the
normal melanin-producing cells (melanocytes), producing a
malignant melanoma. These tumors secrete a colorless precursor of melanin, 5,6-dihydroxyindole, which oxidizes to
melanogen and then to melanin, producing the characteristic
dark urine.
PROCEDURE 8-3
Alkaptonuria
TECHNICAL TIP It is important to differentiate between
the presence of homogentisic acid and melanin when
urine is observed to have turned black upon standing.
Alkaptonuria was one of the six original inborn errors of metabolism described by Garrod in 1902. The name alkaptonuria
was derived from the observation that urine from patients with
this condition darkened after becoming alkaline from standing
at room temperature. Therefore, the term “alkali lover,” or
alkaptonuria, was adopted. This metabolic defect is actually
the third major defect in the phenylalanine-tyrosine pathway
and occurs from failure to inherit the gene to produce the
enzyme homogentisic acid oxidase. Without this enzyme, the
phenylalanine-tyrosine pathway cannot proceed to completion, and homogentisic acid accumulates in the blood, tissues,
and urine. This condition does not usually manifest itself clinically in early childhood, but observations of brown-stained
or black-stained cloth diapers and reddish-stained disposable
diapers have been reported.3 In later life, brown pigment becomes deposited in the body tissues (particularly noticeable
in the ears). Deposits in the cartilage eventually lead to arthritis. A high percentage of persons with alkaptonuria develop
liver and cardiac disorders.4
Homogentisic acid reacts in several of the routinely used
screening tests for metabolic disorders, including the ferric
chloride test, in which a transient deep blue color is produced
in the tube test. A yellow precipitate is produced in the Clinitest, indicating the presence of a reducing substance. Another
screening test for urinary homogentisic acid is to add alkali to
freshly voided urine and to observe for darkening of the color;
however, large amounts of ascorbic acid interfere with this
reaction.
Paper and thin layer chromatography procedures are available for quantitating homogentisic acid. The silver nitrate test
for homogentisic acid is provided in Procedure 8-3.
TECHNICAL TIP The appearance of black urine from a
patient of any age should be reported to a supervisor.
TECHNICAL TIP Melanin may react with sodium nitroferricyanide (acetone reagent strip), producing a red color.
Homogentisic Acid Test
1. Place 4 mL of 3% silver nitrate in a tube.
2. Add 0.5 mL of urine.
3. Mix.
4. Add 10% NH4OH by drops.
5. Observe for black color.
Branched-Chain Amino Acid Disorders
The branched-chain amino acids differ from other amino acids
by having a methyl group that branches from the main
aliphatic carbon chain (Fig. 8–3 A and B). Two major groups
of disorders are associated with errors in the metabolism of the
branched-chain amino acids. In one group, accumulation of
one or more of the early amino acid degradation products occurs, as is seen in maple syrup urine disease. Disorders in the
other group are termed organic acidemias and result in accumulation of organic acids produced further down in the amino
acid metabolic pathway.
A significant laboratory finding in branched-chain amino
acid disorders is the presence of ketonuria in a newborn.
Maple Syrup Urine Disease
Although maple syrup urine disease (MSUD) is rare, a brief
discussion is included in this chapter because the urinalysis
laboratory can provide valuable information for the essential
early detection of this disease. MSUD is also included in newborn screening profiles using MS/MS.
MSUD is caused by an IEM, inherited as an autosomal
recessive trait. The amino acids involved are leucine,
isoleucine, and valine. The metabolic pathway begins normally, with the transamination of the three amino acids in the
liver to the keto acids (α -ketoisovaleric, α -ketoisocaproic,
and α -keto-β -methylvaleric). Failure to inherit the gene for
the enzyme necessary to produce oxidative decarboxylation
of these keto acids results in their accumulation in the blood
and urine.1
Newborns with MSUD begin to exhibit clinical symptoms
associated with failure to thrive after approximately l week. The
presence of the disease may be suspected from these clinical
symptoms; however, many other conditions have similar symptoms. Personnel in the urinalysis laboratory or in the nursery
may detect the disease by noticing a urine specimen that produces a strong odor resembling maple syrup that is caused by
the rapid accumulation of keto acids in the urine. Even though
3920_Ch08_163-179 23/01/14 10:23 AM Page 168
Part Two | Urinalysis
168
Alpha Amino Group
H
H
N
H
A
Alpha Amino Group
C
O
H
R Group
(Variant)
H
N
C
R
Carboxyl Group
H
OH
C
a report of urine odor is not a part of the routine urinalysis, notifying the physician about this unusual finding can prevent
progression to severe mental retardation and even death. Studies have shown that if maple syrup urine disease is detected by
the 11th day, dietary regulation and careful monitoring of
urinary keto acid concentrations can control the disorder.5
The 2,4-dinitrophenylhydrazine (DNPH) urine screening test
for MSUD is provided in Procedure 8-4.
Organic Acidemias
Generalized symptoms of the organic acidemias include early
severe illness, often with vomiting accompanied by metabolic
acidosis; hypoglycemia; ketonuria; and increased serum ammonia.6 The three most frequently encountered disorders are
isovaleric, propionic, and methylmalonic acidemia.
Isovaleric acidemia may be suspected when urine specimens, and sometimes even the patient, possess a characteristic
odor of “sweaty feet.” This odor is caused by the accumulation
of isovalerylglycine due to a deficiency of isovaleryl coenzyme
A in the leucine pathway.
The presence of isovaleric, propionic, and methylmalonic
acidemias can be detected by newborn screening programs
using MS/MS.
Propionic and methylmalonic acidemias result from errors
in the metabolic pathway converting isoleucine, valine, threonine, and methionine to succinyl coenzyme A. Propionic
acid is the immediate precursor to methylmalonic acid in this
pathway.
Tryptophan Disorders
The major concern of the urinalysis laboratory in the metabolism of tryptophan is the increased urinary excretion of the
metabolites indican and 5-hydroxyindoleacetic acid (5-HIAA).
PROCEDURE 8-4
2,4-Dinitrophenylhydrazine (DNPH) Test for MSUD
1. Place 1 mL of urine in a tube.
2. Add 10 drops of 0.2% 2,4-DNPH in 2N HCl.
3. Wait 10 minutes.
4. Observe for yellow turbidity or precipitate.
C
CH
H 3C
B
O
CH3
Leucine Group
OH
Figure 8–3 α -Alpha amino acid
and branched chain amino acid
structures. A. Structure of an
α -amino acid. B. Structure of
the branched chain amino acid
leucine.
Figure 8–4 shows a simplified diagram of the metabolic pathways by which these substances are produced. Other metabolic
pathways of tryptophan are not included because they do not
relate directly to the urinalysis laboratory.
Indicanuria
Under normal conditions, most of the tryptophan that enters
the intestine is either reabsorbed for use by the body in producing protein or is converted to indole by intestinal bacteria
and excreted in the feces. However, in certain intestinal disorders (including obstruction; the presence of abnormal bacteria; malabsorption syndromes; and Hartnup disease, a rare
inherited disorder, increased amounts of tryptophan are converted to indole. The excess indole is then reabsorbed from
the intestine into the bloodstream and circulated to the liver,
where it is converted to indican and then excreted in the
urine. Indican excreted in the urine is colorless until oxidized
to the dye indigo blue by exposure to air. Early diagnosis of
Hartnup disease is sometimes made when a mother reports a
blue staining of her infant’s diapers, referred to as the “blue
diaper syndrome.”
Except in cases of Hartnup disease, correction of the underlying intestinal disorder returns urinary indican levels to
normal. The inherited defect in Hartnup disease affects not
only the intestinal reabsorption of tryptophan but also the
renal tubular reabsorption of other amino acids, resulting in
a generalized aminoaciduria (Fanconi syndrome). The defective renal transport of amino acids does not appear to affect
other renal tubular functions. Therefore, with proper dietary
supplements, including niacin, people with Hartnup disease
have a good prognosis.7
5-Hydroxyindoleacetic Acid
As shown in Figure 8–4, a second metabolic pathway of
tryptophan is for the production of serotonin used in the
stimulation of smooth muscles. Serotonin is produced from
tryptophan by the argentaffin cells in the intestine and is carried through the body primarily by the platelets. Normally,
the body uses most of the serotonin, and only small amounts
of its degradation product, 5-HIAA, are available for excretion in the urine. However, when carcinoid tumors involving
the argentaffin (enterochromaffin) cells develop, excess
amounts of serotonin are produced, resulting in the elevation
of urinary 5-HIAA levels.
3920_Ch08_163-179 23/01/14 10:23 AM Page 169
Chapter 8 | Urine Screening for Metabolic Disorders
169
Tryptophan
(normal)
Abnormal
Abnormal
Intestinal disorder
Malignant tumors
Excess indole
5-Hydroxytryptophan
Reabsorbed from intestine
into bloodstream
Liver
Indican
Indole
Serotonin
Feces
5-Hydroxyindoleacetic
acid (5-HIAA)
Urine
Exposure to air
Indigo blue
Figure 8–4 Tryptophan metabolism.
Adding nitrous acid and 1-nitroso-2-naphthol to urine that
contains 5-HIAA causes the urine to turn purple to black, depending on the amount of 5-HIAA present (Procedure 8-5). The
normal daily excretion of 5-HIAA is 2 to 8 mg, and excretion of
greater than 25 mg/24 h can be an indication of argentaffin cell
tumors.8 The test can be performed on a random or first morning specimen; however, false-negative results can occur based
on the specimen concentration and also because 5-HIAA
may not be produced at a constant rate throughout the day. If a
24-hour sample is used, it must be preserved with hydrochloric
or boric acid. A plasma method using high-performance liquid
chromatography with fluorescence detection is also available.
Patients must be given explicit dietary instructions before
collecting any sample to be tested for 5-HIAA, because serotonin
is a major constituent of foods such as bananas, pineapples, and
tomatoes. Medications, including phenothiazines and acetanilids,
also interfere with results. Patients should be directed to withhold
medications for 72 hours before specimen collection.
Cystine Disorders
Two distinct disorders of cystine metabolism exhibit renal
manifestations. Confusion as to their relationship existed for
many years following the discovery of renal calculi consisting
PROCEDURE 8-5
Silver Nitroprusside Test
1. Place 1 mL of urine in a tube.
2. Add two drops concentrated NH4OH.
3. Add 0.5 mL 5% silver nitrate.
4. Wait 10 minutes.
5. Add five drops sodium nitroprusside.
6. Observe for purple-black color.
of cystine. It is now known that although both disorders are
inherited, one is a defect in the renal tubular transport of amino
acids (cystinuria) and the other is an IEM (cystinosis). A noticeable odor of sulfur may be present in the urine of people
with cystine metabolism disorders.
Cystinuria
As the name implies, cystinuria is marked by elevated amounts
of the amino acid cystine in the urine. The presence of increased urinary cystine is not due to a defect in the metabolism
of cystine but, rather, to the inability of the renal tubules to reabsorb cystine filtered by the glomerulus. The demonstration
that not only cystine but also lysine, arginine, and ornithine
are not reabsorbed has ruled out the possibility of an error
in metabolism even though the condition is inherited.9 The
disorder has two modes of inheritance: one in which reabsorption of all four amino acids—cystine, lysine, arginine, and
ornithine—is affected, and the other in which only cystine and
lysine are not reabsorbed. Genetic studies have grouped cystinuria into three types based on the two inherited genes and their
heterozygous and homozygous inheritance. In general, persons
with any form of inheritance may form renal calculi but the
calculi are less common in persons in whom only lysine and
cystine are affected.10 Approximately 65% of the people in
whom all four amino acids are affected can be expected to produce calculi early in life.
Because cystine is much less soluble than the other three
amino acids, laboratory screening determinations are based on
observing cystine crystals in the sediment of concentrated or
first morning specimens. Cystine is also the only amino acid
found during the analysis of calculi from these patients. A
chemical screening test for urinary cystine can be performed
using cyanide-nitroprusside. Reduction of cystine by sodium
cyanide followed by the addition of nitroprusside produces
a red-purple color in a specimen that contains excess cystine
(see Procedure 8-6). False-positive reactions occur in the
3920_Ch08_163-179 23/01/14 10:23 AM Page 170
170
Part Two | Urinalysis
PROCEDURE 8-6
Cyanide-Nitroprusside Test for Cystine
1. Place 3 mL of urine in a tube.
2. Add 2 mL sodium cyanide.
3. Wait 10 minutes.
4. Add five drops 5% sodium nitroprusside.
5. Observe for red-purple color.
an additional screening test for homocystinuria must be performed by following a positive cyanide-nitroprusside test
result with a silver-nitroprusside test, in which only homocystine will react. The use of silver nitrate in place of sodium
cyanide reduces homocystine to its nitroprusside-reactive
form but does not reduce cystine. Consequently, a positive reaction in the silver-nitroprusside test confirms the presence of
homocystinuria. Fresh urine should be used when testing for
homocystine (see Procedure 8-7).
Porphyrin Disorders
presence of ketones and homocystine, and additional tests may
have to be performed.
Cystinosis
Regarded as a genuine IEM, cystinosis can occur in three variations, ranging from a severe fatal disorder developed in infancy
to a benign form appearing in adulthood. The disorder has two
general categories, termed nephropathic and nonnephropathic.
The nephropathic category is subdivided into infantile and lateonset cystinosis. A defect in the lysosomal membranes prevents
the release of cystine into the cellular cytoplasm for metabolism.
The incomplete metabolism of cystine results in crystalline
deposits of cystine in many areas of the body, including the
cornea, bone marrow, lymph nodes, and internal organs.
A major defect in the renal tubular reabsorption mechanism
(Fanconi syndrome) also occurs. The renal tubules, particularly
the proximal convoluted tubules, are affected by the cystine deposits that interfere with reabsorption. This is not an inherited
disorder of renal tubular reabsorption, as seen in cystinuria.
Continued deposition of cystine, if untreated, results in renal
failure early in life. In infantile nephropathic cystinosis, there is
rapid progression to renal failure. In late-onset nephropathic
cystinosis, there is a gradual progression to total renal failure.
Renal transplants and the use of cystine-depleting medications
to prevent the buildup of cystine in other tissues are extending
lives. Nonnephropathic cystinosis is relatively benign but may
cause some ocular disorders.
Routine laboratory findings in infantile nephropathic
cystinosis include polyuria, generalized aminoaciduria, positive
Clinitest results for reducing substances, and lack of urinary
concentration.
Porphyrins are the intermediate compounds in the production
of heme. The basic pathway for heme synthesis presented in
Figure 8–5 shows the three primary porphyrins (uroporphyrin, coproporphyrin, and protoporphyrin) and the porphyrin precursors (α -aminolevulinic acid [ALA] and
porphobilinogen). As can be seen, the synthesis of heme can
be blocked at a number of stages. Blockage of a pathway reaction results in the accumulation of the product formed just
before the interruption. Detection and identification of this
product in the urine, bile, feces, or blood can then aid in determining the cause of a specific disorder.
The solubility of the porphyrin compounds varies with
their structure. ALA, porphobilinogen, and uroporphyrin are
the most soluble and readily appear in the urine. Coproporphyrin is less soluble but is found in the urine, whereas protoporphyrin is not seen in the urine. Fecal analysis has usually
been performed to detect coproporphyrin and protoporphyrin.
However, to avoid false-positive interference, bile is a more acceptable specimen.11 The Centers for Disease Control and Prevention (CDC) recommends analysis of whole blood for the
presence of free erythrocyte protoporphyrin (FEP) as a screening test for lead poisoning.
Disorders of porphyrin metabolism are collectively termed
porphyrias. They can be inherited or acquired from erythrocytic and hepatic malfunctions or exposure to toxic agents.
Common causes of acquired porphyrias include lead poisoning, excessive alcohol intake, iron deficiency, chronic liver disease, and renal disease. Inherited porphyrias are much rarer
than acquired porphyrias. They are caused by failure to inherit
the gene that produces an enzyme needed in the metabolic
pathway. The enzyme deficiency sites for some of the more
Homocystinuria
Defects in the metabolism of the amino acid methionine produce an increase in homocystine throughout the body. The
increased homocystine can result in failure to thrive, cataracts,
mental retardation, thromboembolic problems, and death.
Early detection of this disorder (homocystinuria) and a change
in diet that excludes foods high in methionine can alleviate the
metabolic problems. Therefore, screening for homocystine is
included in newborn screening programs. Newborn screening
tests are performed using MS/MS testing.
As mentioned, increased urinary homocystine gives a
positive result with the cyanide-nitroprusside test. Therefore,
PROCEDURE 8-7
Silver Nitroprusside Test for Homocystine
1. Place 1 mL of urine in a tube.
2. Add two drops concentrated NH4OH.
3. Add 0.5 mL 5% silver nitrate.
4. Wait 10 minutes.
5. Add five drops sodium nitroprusside.
6. Observe for red-purple color.
3920_Ch08_163-179 23/01/14 10:23 AM Page 171
Chapter 8 | Urine Screening for Metabolic Disorders
171
HEME SYNTHESIS
Glycine and Succinyl-CoA
Aminolevulinic acid synthetase
γ-Aminolevulinate (ALA)
Aminolevulinic acid synthetase
Lead exposure
ALA hydratase deficiency porphyria
Porphobilinogen
Uroporphyrinogen synthase
Acute intermittent porphyria
Hydroxymethylbilane
Uroporphyrinogen cosynthase
Congenital erythropoietic porphyria
Uroporphyrinogen (UPG)
Uroporphyrinogen decarboxylase
Porphyria cutanea tarda
Coproporphyrinogen (CPG)
Coproporphyrinogen oxidase
Hereditary coproporphyria
Protoporphyrinogen
Protoporphyrinogen oxidase
Variate porphyria
Protoporphyrin IX
Ferrochelatase
Figure 8–5 Pathway of heme formation, including normal
pathway (green), enzymes (orange), and stages affected by
the major disorders (yellow) of porphyrin metabolism.
common porphyrias are shown in Figure 8–5. The inherited
porphyrias are frequently classified by their clinical symptoms,
either neurologic/psychiatric or cutaneous photosensitivity or
a combination of both (Table 8–3).
An indication of the possible presence of porphyrinuria
is the observation of a red or port wine color to the urine after
exposure to air. The port wine urine color is more prevalent in
the erythropoietic porphyrias, and staining of the teeth may
also occur. As seen with other inherited disorders, the presence
of congenital porphyria is sometimes suspected from a red discoloration of an infant’s diapers.
The two screening tests for porphyrinuria use the Ehrlich
reaction and fluorescence under ultraviolet light in the 550- to
600-nm range. The Ehrlich reaction can be used only for the
Lead exposure
Erythropoietic protoporphyria
Heme
detection of ALA and porphobilinogen. Acetyl acetone must
be added to the specimen to convert the ALA to porphobilinogen prior to performing the Ehrlich test. The fluorescent technique must be used for the other porphyrins. The Ehrlich
reaction that is now included in the Multistix urobilinogen pad
was originally used for all urobilinogen testing. Variations of
the Ehrlich reaction include the Watson-Schwartz test for differentiation between the presence of urobilinogen and porphobilinogen (see Procedures 8-8 and 8-9) and the Hoesch test
(Procedure 8-10).
Testing for the presence of porphobilinogen is most useful
when patients exhibit symptoms of an acute attack. This can
be done with the Hoesch test. Increased porphobilinogen is
associated with acute intermittent porphyria. A negative test
3920_Ch08_163-179 23/01/14 10:23 AM Page 172
172
Part Two | Urinalysis
Table 8–3
Common Porphyrias
Porphyria
Elevated Compound(s)
Clinical Symptoms
Laboratory Testing
Acute intermittent porphyria
Porphyria cutanea tarda
Congenital erythropoietic
porphyria
Neurologic/psychiatric
Photosensitivity
Photosensitivity
Urine/Ehrlich reaction
Urine fluorescence
Urine or feces fluorescence
Variegate porphyria
ALA Porphobilinogen
Uroporphyrin
Uroporphyrin
Coproporphyrin
Coproporphyrin
Bile or feces fluorescence
Erythropoietic protoporphyria
Protoporphyrin
Photosensitivity/
neurologic
Photosensitivity
Lead poisoning
ALA
Neurologic
Protoporphyrin
HISTORICAL NOTE
Vampires in Old Europe
Did you ever wonder how the legend of vampires got
started? Think about the previous discussion on the symptoms and inheritance of porphyrias.
Photosensitivity→ Avoidance of sunlight
Pale coloring→ Anemia caused by heme disorder
Port wine− colored urine, red-stained teeth→ Drinking
blood
Psychiatric symptoms→ Abnormal behavior
Inherited disorder→ Familial association, small gene
pool
Dracula is associated with Transylvania, now Romania.
Porphyria was a common disease of early royalty in
Europe as a result of intermarriage among the royals of
different countries. King George III reportedly died blind,
deaf, and mad from porphyria.
result is obtained in the presence of lead poisoning unless ALA
is first converted to porphobilinogen.
Fluorescent screening for the other porphyrins uses
their extraction into a mixture of glacial acetic acid and ethyl
acetate. The solvent layer is then examined. Negative reactions have a faint blue fluorescence. Positive reactions fluoresce as violet, pink, or red, depending on the concentration
of porphyrins. If the presence of interfering substances is
suspected, the organic layer can be removed to a separate
tube, and 0.5 mL of hydrochloric acid added to the tube.
Only porphyrins are extracted into the acid layer, which then
produces a bright orange-red fluorescence. The fluorescence
method does not distinguish among uroporphyrin, coproporphyrin, and protoporphyrin, but it rules out porphobilinogen and ALA. Identifying specific porphyrins requires
additional techniques and the analysis of fecal and erythrocyte samples. Increased protoporphyrin is best measured in
whole blood.
Blood FEP
Bile or feces fluorescence
Acetoacetic acid + urine/
Ehrlich reaction
Blood FEP
Mucopolysaccharide
Disorders
Mucopolysaccharides, or glycosaminoglycans, are a group
of large compounds located primarily in the connective tissue. They consist of a protein core with numerous polysaccharide branches. Inherited disorders in the metabolism of
these compounds prevent complete breakdown of the polysaccharide portion of the compounds, resulting in accumulation of the incompletely metabolized polysaccharide
portions in the lysosomes of the connective tissue cells and
their increased excretion in the urine. The products most
frequently found in the urine are dermatan sulfate, keratan
sulfate, and heparan sulfate, with the appearance of a particular substance being determined by the specific metabolic
error that was inherited.12 Therefore, identification of the
specific enzyme deficiency is necessary to establish a specific
diagnosis.
There are many types of mucopolysaccharidoses, but
the best known are Hurler syndrome, Hunter syndrome, and
Sanfilippo syndrome. In both Hurler and Hunter syndromes,
the skeletal structure is abnormal and there is severe mental
retardation; in Hurler syndrome, mucopolysaccharides accumulate in the cornea of the eye. Hunter syndrome is inherited
as sex-linked recessive and is rarely seen in females. Without
treatment, both syndromes are usually fatal during childhood,
whereas in Sanfilippo syndrome, the only abnormality is mental retardation. Bone marrow transplants and gene replacement therapy are the most promising treatments for these
disorders.
Urinary screening tests for mucopolysaccharides may
be requested either as part of a routine battery of tests
performed on all newborns or on infants who exhibit symptoms of mental retardation or failure to thrive. The most
frequently used screening tests are the acid-albumin and
cetyltrimethylammonium bromide (CTAB) turbidity tests
and the metachromatic staining spot tests. In both the
acid-albumin and the CTAB tests, a thick, white turbidity
forms when these reagents are added to urine that contains
3920_Ch08_163-179 23/01/14 10:23 AM Page 173
Chapter 8 | Urine Screening for Metabolic Disorders
173
PROCEDURE 8-8
PROCEDURE 8-9
Watson-Schwartz Differentiation Test
The classic test for differentiating between urobilinogen,
porphobilinogen, and Ehrlich-reactive compounds is the
Watson-Schwartz test. The test is performed as follows:
1. To each tube add:
Tube 1
Tube 2
2 mL urine
2 mL urine
2 mL chloroform
2 mL butanol
4 mL sodium acetate
4 mL sodium acetate
2. Observe the color of the layers.
3. Interpretation:
The addition of chloroform to Tube 1 results in the extraction of urobilinogen into the chloroform (bottom) layer,
producing a colorless urine (top) layer, and a red chloroform
layer on the bottom. Neither porphobilinogen nor other
Ehrlich-reactive compounds are soluble in chloroform.
Porphobilinogen is also not soluble in butanol; however,
urobilinogen and other Ehrlich-reactive compounds are extracted into butanol. Therefore, the addition of butanol to
Tube 2 produces a red (upper) butanol layer if urobilinogen
or Ehrlich-reactive compounds are present and a colorless
butanol layer if porphobilinogen is present. As shown in the
figure, urobilinogen is soluble in both chloroform and
butanol, and porphobilinogen is soluble in neither. If both
urobilinogen and porphobilinogen are present, both layers
appear red. Before reporting the test as positive for both
substances, an additional chloroform extraction should be
performed on the red urine (upper) layer in Tube 1 to ensure
that the red color is not due to excess urobilinogen.
Watson-Schwartz Test
1. Label two tubes #1 and #2.
2. To each tube add:
Tube 1
Tube 2
2 mL urine
2 mL urine
2 mL chloroform
2 mL butanol
4 mL sodium acetate
4 mL sodium acetate
3. Vigorously shake both tubes.
4. Place in a rack for layers to settle.
5. Observe both tubes for red color in the layers.
Interpretation:
Tube 1
Upper layer = urine; if colorless = porphobilinogen or
Ehrlich-reactive compounds.
Bottom layer = chloroform; if red = urobilinogen.
UR
B
UR
B
UR
B
C
UR
C
UR
C
UR
Urobilinogen
Porphobilinogen
Ehrlich-reactive
UR
B
UR
UR
C
UR
C
C
Urobilinogen/porphobilinogen
Watson-Schwartz reactions.
Excess urobilinogen
If both layers are red, re-extract the urine layer from
tube 1.
Place 2 mL of urine layer from Tubes 1 and 2 mL chloroform and 4 mL sodium acetate into a new tube. Repeat
procedure.
Interpretation: Upper layer—urine colorless
Bottom layer—chloroform—red = excess urobilinogen
Both layers red = porphobilinogen and urobilinogen
Tube 2
Upper layer = butanol
If red = urobilinogen or
Ehrlich-reactive compounds
Bottom layer = urine
If colorless = porphobilinogen
PROCEDURE 8-10
Hoesch Screening Test for Porphobilinogen
The Hoesch test is used for rapid screening or monitoring
of urinary porphobilinogen.
1. Two drops of urine are added to approximately 2 mL of
Hoesch reagent (Ehrlich reagent dissolved in 6 M HCl).
2. Immediately observed the top of the solution for the
appearance of a red color that indicates the presence
of porphobilinogen.
3. Shake the tube.
Interpretation:
When the tube is shaken, the red color is seen throughout
the solution. The test detects approximately 2 mg/dL of
porphobilinogen, and urobilinogen is inhibited by the
highly acidic pH. High concentrations of methyldopa and
indican, and highly pigmented urines, may produce falsepositive results.
3920_Ch08_163-179 23/01/14 10:23 AM Page 174
174
Part Two | Urinalysis
mucopolysaccharides. Turbidity is usually graded on a scale
of 0 to 4 after 30 minutes with acid-albumin and after
5 minutes with CTAB.13 (See Procedure 8-11.)
Purine Disorders
A disorder of purine metabolism known as Lesch-Nyhan
disease that is inherited as a sex-linked recessive results in
massive excretion of urinary uric acid crystals. Failure to inherit the gene to produce the enzyme hypoxanthine guanine
phosphoribosyltransferase is responsible for the accumulation
of uric acid throughout the body. Patients suffer from severe
motor defects, mental retardation, a tendency toward selfdestruction, gout, and renal calculi. Development is usually
normal for the first 6 to 8 months, and the first sign is often
uric acid crystals resembling orange sand in diapers.7 Laboratories should be alert for the presence of increased uric acid
crystals in pediatric urine specimens.
Galactosuria can be caused by a deficiency in any of three
enzymes, galactose-1-phosphate uridyl transferase (GALT),
galactokinase, and UDP-galactose-4-epimerase. Of these enzymes, it is GALT deficiency that causes the severe, possibly fatal
symptoms associated with galactosemia. Newborn screening
protocols currently test for the presence of GALT deficiency. The
enzyme is measured in the red blood cells as part of the newborn
heel puncture protocol. As a result, people with deficiencies in
the other two enzymes may still produce galactosuria but have
negative newborn screening tests. Galactose kinase deficiency
can result in cataracts in adulthood. UDP-galactose-4-epimerase
deficiency may be asymptomatic or produce mild symptoms.
Other causes of melituria include lactose, fructose, and
pentose. Lactosuria may be seen during pregnancy and lactation. Fructosuria is associated with parenteral feeding and
pentosuria with ingestion of large amounts of fruit. Additional
tests including chromatography can be used to identify other
nonglucose reducing substances.
Carbohydrate Disorders
The presence of increased urinary sugar (melituria) is most
frequently due to an inherited disorder. In fact, pentosuria was
one of Garrod’s original six IEMs.14 Fortunately, most meliturias cause no disturbance to body metabolism. However, as
discussed in Chapter 5, pediatric urine should be routinely
screened for the presence of reducing substances using the
Clinitest procedure. The finding of a positive copper reduction
test result combined with a negative reagent strip glucose oxidase test result is strongly suggestive of a disorder of carbohydrate metabolism. Of primary concern is the presence of
galactosuria, indicating the inability to properly metabolize
galactose to glucose. The resulting galactosemia with toxic intermediate metabolic products results in infant failure to thrive,
combined with liver disorders, cataracts, and severe mental retardation. Early detection of galactosuria followed by removal
of lactose (a disaccharide containing galactose and glucose)
from the diet can prevent these symptoms.
PROCEDURE 8-11
Cetyltrimethylammonium Bromide (CTAB) Test for
Mucopolysaccharides
1. Place 5 mL of urine in a tube.
2. Add 1 mL 5% CTAB in citrate buffer.
3. Read turbidity in 5 minutes.
TECHNICAL TIP Lesch-Nyhan disease should not be
confused with uromodulin-associated kidney disease, in
which the uric acid crystals appear later in life.
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Frimpton, GW: Aminoacidurias due to inherited disorders of
metabolism. N Engl J Med 1289:835–901, 1973.
2. National newborn screening and genetics resource center. Web
site: http:// www.genes-r-us.uthscsa.edu Accessed January 17,
2007.
3. Nyhan, WL, and Sakati, NO: Diagnostic Recognition of Genetic
Disease. Lea & Febiger, Philadelphia, 1987.
4. Stanbury, JB: The Metabolic Basis of Inherited Diseases.
McGraw-Hill, New York, 1983.
5. Clow, CL, Reade, TH, and Scriver, CR: Outcome of early and
long-term management of classical maple syrup urine disease.
Pediatrics 68(6):856–862, 1981.
6. Goodman, SI: Disorders of organic acid metabolism. In Emery,
AEH, and Rimoin, DL: Principles and Practice of Medical
Genetics. Churchill Livingstone, New York, 1990.
7. Jepson, JB: Hartnup’s disease. In Stanbury, JB, Wyngaarden, JB,
and Fredrickson, DS (eds): The Metabolic Basis of Inherited
Diseases. McGraw-Hill, New York, 1983.
8. Van Leeuwen, AM, Poelhuis-Leth, DJ, and Bladh, ML: Davis’s
Comprehensive Laboratory and Diagnostics Handbook. 4th ed.
Philadelphia, FA Davis Company; 2011
9. Nyhan, WL: Abnormalities in Amino Acid Metabolism in Clinical Medicine. Appleton-Century-Crofts, Norwalk, CT., 1984.
10. Dello Strolongo, L, et al: Comparison between SLC3A1 and
SLC7A9 cystinuria patients and carriers: A need for a new
classification. J Am Soc Nephrol 13:2547–2553, 2002.
11. Nuttall, KL: Porphyrins and disorders of porphyrin metabolism. In Burtis, CA, and Ashwood, ER: Tietz Fundamentals of
Clinical Chemistry. WB Saunders, Philadelphia, 1996.
12. McKusick, VA, and Neufeld, EF: The mucopolysaccharide storage
diseases. In Stanbury, JB, Wyngaarden, JB, and Fredrickson, DS
(eds): The Metabolic Basis of Inherited Diseases. McGraw-Hill,
New York, 1983.
13. Kelly, S: Biochemical Methods in Medical Genetics. Charles C.
Thomas, Springfield, IL, 1977.
14. Garrod, AE: Inborn Errors of Metabolism. Henry Froude &
Hodder & Stoughton, London, 1923.
3920_Ch08_163-179 23/01/14 10:24 AM Page 175
Chapter 8 | Urine Screening for Metabolic Disorders
175
Study Questions
1. All states require newborn screening for PKU for early:
A. Modifications of diet
B. Administration of antibiotics
C. Detection of diabetes
D. Initiation of gene therapy
2. All of the following disorders can be detected by newborn
screening except:
A. Tyrosyluria
B. MSUD
C. Melanuria
D. Galactosemia
3. The best specimen for early newborn screening is a:
A. Timed urine specimen
B. Blood specimen
C. First morning urine specimen
D. Fecal specimen
4. Abnormal urine screening tests categorized as an overflow
disorder include all of the following except:
A. Alkaptonuria
B. Galactosemia
C. Melanuria
D. Cystinuria
5. Which of the following disorders is not associated with the
phenylalanine-tyrosine pathway?
A. MSUD
B. Alkaptonuria
C. Albinism
D. Tyrosinemia
6. The least serious form of tyrosylemia is:
A. Immature liver function
B. Type 1
C. Type 2
D. Type 3
7. An overflow disorder of the phenylalanine-tyrosine pathway that would produce a positive reaction with the reagent
strip test for ketones is:
A. Alkaptonuria
B. Melanuria
C. MSUD
D. Tyrosyluria
8. An overflow disorder that could produce a false-positive
reaction with Clinitest procedure is:
A. Cystinuria
B. Alkaptonuria
C. Indicanuria
D. Porphyrinuria
9. A urine that turns black after sitting by the sink for
several hours could be indicative of:
A. Alkaptonuria
B. MSUD
C. Melanuria
D. Both A and C
10. Ketonuria in a newborn is an indication of:
A. MSUD
B. Isovaleric acidemia
C. Methylmalonic acidemia
D. All of the above
11. Urine from a newborn with MSUD will have a
significant:
A. Pale color
B. Yellow precipitate
C. Milky appearance
D. Sweet odor
12. Hartnup disease is a disorder associated with the metabolism of:
A. Organic acids
B. Tryptophan
C. Cystine
D. Phenylalanine
13. 5-HIAA is a degradation product of:
A. Heme
B. Indole
C. Serotonin
D. Melanin
14. Elevated urinary levels of 5-HIAA are associated with:
A. Carcinoid tumors
B. Hartnup disease
C. Cystinuria
D. Platelet disorders
3920_Ch08_163-179 23/01/14 10:24 AM Page 176
176
Part Two | Urinalysis
15. False-positive levels of 5-HIAA can be caused by a diet
high in:
A. Meat
B. Carbohydrates
C. Starch
D. Bananas
22. Which of the following specimens can be used for
porphyrin testing?
A. Urine
B. Blood
C. Feces
D. All of the above
16. Place the appropriate letter in front of the following
statements.
A. Cystinuria
B. Cystinosis
____ IEM
____ Inherited disorder of tubular reabsorption
____ Fanconi syndrome
____ Cystine deposits in the cornea
____ Early renal calculi formation
23. The two stages of heme formation affected by lead
poisoning are:
A. Porphobilinogen and uroporphyrin
B. Aminolevulinic acid and porphobilinogen
C. Coproporphyrin and protoporphyrin
D. Aminolevulinic acid and protoporphyrin
17. Blue diaper syndrome is associated with:
A. Lesch-Nyhan syndrome
B. Phenylketonuria
C. Cystinuria
D. Hartnup disease
18. Homocystinuria is caused by failure to metabolize:
A. Lysine
B. Methionine
C. Arginine
D. Cystine
19. The Ehrlich reaction will only detect the presence of:
A. Uroporphyrin
B. Porphobilinogen
C. Coproporphyrin
D. Protoporphyrin
20. Acetyl acetone is added to the urine before performing the
Ehrlich test when checking for:
A. Aminolevulinic acid
B. Porphobilinogen
C. Uroporphyrin
D. Coproporphyrin
21. The classic urine color associated with porphyria is:
A. Dark yellow
B. Indigo blue
C. Pink
D. Port wine
24. Hurler, Hunter, and Sanfilippo syndromes are hereditary
disorders affecting metabolism of:
A. Porphyrins
B. Purines
C. Mucopolysaccharides
D. Tryptophan
25. Many uric acid crystals in a pediatric urine specimen may
indicate:
A. Hurler syndrome
B. Lesch-Nyhan disease
C. Melituria
D. Sanfilippo syndrome
26. Deficiency of the GALT enzyme will produce a:
A. Positive Clinitest
B. Glycosuria
C. Galactosemia
D. Both A and C
27. Match the metabolic urine disorders with their classic
urine abnormalities.
____ PKU
A. Sulfur odor
____ Indicanuria
B. Sweaty feet odor
____ Cystinuria
C. Orange sand in diaper
____ Alkaptonuria
D. Mousy odor
____ Lesch-Nyhan disease
E. Black color
____ Isovaleric acidemia
F. Blue color
3920_Ch08_163-179 23/01/14 10:24 AM Page 177
Chapter 8 | Urine Screening for Metabolic Disorders
177
Case Studies and Clinical Situations
1. A premature infant develops jaundice. Laboratory tests
are negative for hemolytic disease of the newborn, but
the infant’s bilirubin level continues to rise. Abnormal
urinalysis results include a dark yellow color, positive
bilirubin, and needle-shaped crystals seen on microscopic examination.
a. What is the most probable cause of the infant’s
jaundice?
b. Could these same urine findings be associated with an
adult? Explain your answer.
c. What kinds of crystals are present? Name another type
of crystal with a spherical shape that is associated with
this condition.
d. When blood is drawn from this infant, what precaution should be taken to ensure the integrity of the
specimen?
2. A newborn develops severe vomiting and symptoms
of metabolic acidosis. Urinalysis results are positive for
ketones and negative for glucose and other reducing
substances.
a. If the urine had an odor of “sweaty feet,” what metabolic disorder would be suspected?
b. If the newborn was producing dark brown urine with
a sweet odor, what disorder would be suspected?
c. Would an MS/MS screen be helpful for the diagnosis?
3. A 13-year-old boy is awakened with severe back and
abdominal pain and is taken to the emergency department by his parents. A complete blood count is normal.
Family history shows that both his father and uncle are
chronic kidney stone formers. Results of a urinalysis
are as follows:
COLOR: Yellow
KETONES: Negative
APPEARANCE: Hazy
BLOOD: Moderate
SP. GRAVITY: 1.025
BILIRUBIN: Negative
pH: 6.0
UROBILINOGEN: Normal
PROTEIN: Negative
NITRITE: Negative
GLUCOSE: Negative
LEUKOCYTE: Negative
Microscopic:
>15–20 RBCs/hpf
Few squamous epithelial
cells
0–3 WBCs/hpf
Many cystine crystals
a. What condition does the patient’s symptoms represent?
b. What is the physiologic abnormality causing this
condition?
c. If amino acid chromatography was performed on
this specimen, what additional amino acids could be
present?
d. Why are they not present in the microscopic
constituents?
e. Based on the family history, what genetic disorder
should be considered?
4. An 8–month-old boy is admitted to the pediatric unit
with a general diagnosis of failure to thrive. The parents
have observed slowness in the infant’s development of
motor skills. They also mention the occasional appearance of a substance resembling orange sand in the child’s
diapers. Urinalysis results are as follows:
COLOR: Yellow
KETONES: Negative
APPEARANCE: Slightly
BLOOD: Negative hazy
SP. GRAVITY: 1.024
BILIRUBIN: Negative
pH: 5.0
UROBILINOGEN: Normal
PROTEIN: Negative
NITRITE: Negative
GLUCOSE: Negative
LEUKOCYTE: Negative
Microscopic:
Many uric acid crystals
a. Is the urine pH consistent with the appearance of uric
acid crystals?
b. Is there any correlation between the urinalysis results
and the substance observed in the child’s diapers?
Explain your answer.
c. What disorder do the patient’s history and the urinalysis results indicate?
d. Is the fact that this is a male patient of any significance?
Explain your answer.
e. Name the enzyme that is missing.
5. Shortly after arriving for the day shift in the urinalysis
laboratory, a technician notices that an undiscarded urine
has a black color. The previously completed
report indicates the color to be yellow.
a. Is this observation significant? Explain your answer.
b. The original urinalysis report showed the specimen
to be positive for ketones. Is this significant? Why or
why not?
c. If the ketones are negative and the pH is 8.0 is this
significant? Why or why not?
6. Bobby Williams, age 8, is admitted through the emergency department with a ruptured appendix. Although
surgery is successful, Bobby’s recovery is slow, and the
3920_Ch08_163-179 23/01/14 10:24 AM Page 178
178
Part Two | Urinalysis
physicians are concerned about his health prior to the
ruptured appendix. Bobby’s mother states that he has
always been noticeably underweight despite eating a
balanced diet and having strong appetite and that his
younger brother exhibits similar characteristics. A note
in his chart from the first postoperative day reports that
the evening nurse noticed a blue coloration in the urinary
catheter bag.
a. Is the catheter bag color significant?
b. What condition can be suspected from this history?
c. What is Bobby’s prognosis?
7. An anemic patient is suspected of having lead poisoning.
a. What historical urine test was requested?
b. What should be added to the urine before testing?
c. What element of heme synthesis would this be
testing for?
d. Name another substance that can be tested for lead
poisoning.
e. What element of heme synthesis would this test for?
3920_Ch08_163-179 23/01/14 10:24 AM Page 179
3920_Ch09_180-202 23/01/14 10:29 AM Page 180
PART THREE
Other Body Fluids
Chapter 9: Cerebrospinal Fluid
Chapter 10: Semen
Chapter 11: Synovial Fluid
Chapter 12: Serous Fluid
Chapter 13: Amniotic Fluid
Chapter 14: Fecal Analysis
Chapter 15: Vaginal Secretions
3920_Ch09_180-202 23/01/14 10:29 AM Page 181
CHAPTER
9
Cerebrospinal Fluid
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
9-1 State the three major functions of cerebrospinal fluid
(CSF).
9-2 Distribute CSF specimen tubes numbered 1, 2, 3, and
possibly 4 to their appropriate laboratory sections
and correctly preserve them.
9-3 Describe the appearance of normal CSF and the
causes of abnormally appearing CSF.
9-4 Define xanthochromia and state its significance.
9-5 Differentiate between CSF specimens caused by
intracranial hemorrhage and a traumatic tap.
9-6 Calculate CSF total, white blood cell and red blood
cell counts when given the number of cells seen,
amount of specimen dilution, and the squares counted
in the Neubauer chamber.
9-7 Describe the leukocyte content of the CSF in bacterial,
viral, tubercular, and fungal meningitis.
9-8 Describe and state the significance of macrophages in
the CSF.
9-9 Differentiate between the appearance of normal
choroidal cells and malignant cells.
9-10 State the reference values for CSF total protein and
name three pathologic conditions that produce an
elevated CSF protein.
9-11 Determine whether increased CSF albumin or
immunoglobulin is the result of damage to the
blood–brain barrier or central nervous system
production.
9-12 Discuss the significance of CSF electrophoresis,
immunophoresis, and isoelectric focusing findings
in multiple sclerosis and the identification of CSF.
9-13 State the reference values for CSF glucose and name
the possible pathologic significance of a decreased
CSF glucose.
9-14 Discuss the diagnostic value of CSF lactate and glutamine determinations.
9-15 Name the microorganism associated with a positive
India ink preparation.
9-16 Discuss the diagnostic value of the bacterial and
cryptococcal antigen tests.
9-17 Determine whether a suspected case of meningitis is
of bacterial, viral, fungal, or tubercular origin when
presented with pertinent laboratory data.
9-18 Describe the role of the Venereal Disease Research
Laboratories test and fluorescent treponemal antibody-absorption test for syphilis in CSF testing.
KEY TERMS
Arachnoid granulations
Meningitis
Traumatic tap
Blood–brain barrier
Oligoclonal bands
Xanthochromia
Choroid plexuses
Pleocytosis
Meninges
Subarachnoid space
3920_Ch09_180-202 23/01/14 10:30 AM Page 182
182
Part Three | Other Body Fluids
Cerebrospinal fluid (CSF) is a major fluid of the body. CSF
provides a physiologic system to supply nutrients to the nervous tissue, remove metabolic wastes, and produce a mechanical
barrier to cushion the brain and spinal cord against trauma.
Formation and Physiology
The brain and spinal cord are lined by the meninges, which
consists of three layers: the dura mater (Latin for “hard
mother”), the arachnoid (“spiderweb-like”), and the pia mater
(Latin for “gentle mother”). The outer layer is the dura mater
that lines the skull and vertebral canal. The arachnoid is a filamentous (spider-like) inner membrane. The pia mater is a
thin membrane lining the surfaces of the brain and spinal cord
(Fig. 9–1).
CSF is produced in the choroid plexuses of the two lumbar ventricles and the third and fourth ventricles. In adults,
approximately 20 mL of fluid is produced every hour. The fluid
flows through the subarachnoid space located between the
arachnoid and pia mater (Fig. 9–2). To maintain a volume of
90 to 150 mL in adults and 10 to 60 mL in neonates, the circulating fluid is reabsorbed back into the blood capillaries in
the arachnoid granulations/villae at a rate equal to its production. The cells of the arachnoid granulations act as one-way
valves that respond to pressure within the central nervous system (CNS) and prevent reflux of the fluid.1
The choroid plexuses are capillary networks that form the
CSF from plasma by mechanisms of selective filtration under
hydrostatic pressure and active transport secretion. Therefore,
the chemical composition of the CSF does not resemble an
ultrafiltrate of plasma. Capillary walls throughout the body are
lined with endothelial cells that are loosely connected to allow
passage of soluble nutrients and wastes between the plasma
and tissues. In the choroid plexuses, the endothelial cells have
very tight-fitting junctures that prevent the passage of many
molecules. This tight-fitting structure of the endothelial cells
in the choroid plexuses is termed the blood–brain barrier.
Maintaining the integrity of the blood–brain barrier is
essential to protect the brain from chemicals and other substances circulating in the blood that could harm the brain tissue. In contrast, the junctures also prevent the passage of
helpful substances including antibodies and medications. Disruption of the blood–brain barrier by diseases such as meningitis and multiple sclerosis allows leukocytes, proteins, and
additional chemicals to enter the CSF.
Specimen Collection
and Handling
CSF is routinely collected by lumbar puncture between the
third, fourth, or fifth lumbar vertebra. Although this procedure
is not complicated, it does require certain precautions, including measurement of intracranial pressure and careful technique
to prevent infection or neural tissue damage.
The volume of CSF that can be removed is based on the
volume available in the patient (adult vs. neonate) and the
opening pressure of the CSF, measured when the needle first
enters the subarachnoid space. Elevated pressure requires fluid
to be withdrawn slowly, with careful monitoring of the pressure, and may prevent collection of a large volume.
Specimens are collected in three sterile tubes, which are
labeled 1, 2, and 3 in the order in which they are withdrawn.
• Tube 1 is used for chemical and serologic tests because
these tests are least affected by blood or bacteria introduced as a result of the tap procedure.
• Tube 2 is usually designated for the microbiology
laboratory.
Central canal
Gray matter
White matter
Spinal nerve roots
Dorsal root ganglion
Arachnoid
granulation
Superior
sagittal sinus
Pia mater
Skin
Spinal nerve
Periosteum
Skull
Dura mater
Arachnoid
mater
Arachnoid
Meninges membrane
Pia mater
Subarachnoid space
Gray matter
Subarachnoid
space
Dura
mater
Brain
White matter tissue
A
B
Figure 9–1 The layers of the meninges. A, the layers of the meninges in the brain. B, the layers of the meninges in the spinal cord. (A, from
Scanlon & Sanders, Essentials of Anatomy and Physiology, 6th ed., F. A. Davis Company, Philadelphia, 2011, with permission.)
3920_Ch09_180-202 23/01/14 10:30 AM Page 184
184
Part Three | Other Body Fluids
TECHNICAL TIP If only one tube can be collected, it
must be tested first by microbiology.
TECHNICAL TIP It is not unusual for cell counts requested to be performed on both Tubes 1 and 4 to check
for cellular contamination by the puncture
Table 9–1
Clinical Significance of CSF Appearance
Appearance
Cause
Crystal clear
WBCs
Hazy, turbid,
milky, cloudy
Microorganisms
Protein
Oily
Bloody
Xanthochromic
Xanthochromia is a term used to describe CSF supernatant that is pink, orange, or yellow. A variety of factors can
cause xanthochromia, the most common being the presence
of RBC degradation products. Depending on the amount of
blood and the length of time it has been present, the color will
vary from pink (very slight amount of oxyhemoglobin) to orange (heavy hemolysis) to yellow (conversion of oxyhemoglobin to unconjugated bilirubin). Other causes of xanthochromia
include elevated serum bilirubin, presence of the pigment
carotene, markedly increased protein concentrations, and
melanoma pigment. Xanthochromia that is caused by bilirubin
due to immature liver function is also commonly seen in infants, particularly premature infants. The clinical significance
of CSF appearance is summarized in Table 9–1.
Carotene
Protein
Melanin
Clotted
Protein
Clotting factors
Pellicle
Protein
Clotting factors
Traumatic Collection (Tap)
Grossly bloody CSF can be an indication of intracranial hemorrhage, but it may also be due to the puncture of a blood vessel during the spinal tap procedure. Three visual examinations
of the collected specimens can usually determine whether the
blood is the result of hemorrhage or a traumatic tap.
Uneven Blood Distribution
Blood from a cerebral hemorrhage will be evenly distributed
throughout the three CSF specimen tubes, whereas a traumatic
tap will leave the heaviest concentration of blood in tube 1, and
gradually diminishing amounts in Tubes 2 and 3. Performing
Normal
Meningitis
Meningitis
Disorders affecting
blood–brain
barrier
Production of IgG
within the CNS
Radiographic
contrast media
RBCs
Hemorrhage
Traumatic tap
Hemoglobin
Old hemorrhage
Lysed cells from
traumatic tap
Bilirubin
Figure 9–4 Tubes of CSF. Appearance left to right is normal,
xanthochromic, hemolyzed, and cloudy.
Major Significance
RBC degradation
Elevated serum
bilirubin level
Increased serum
levels
Disorders affecting
blood–brain
barrier
Meningeal
melanosarcoma
Disorders affecting
blood–brain
barrier
Introduced by
traumatic tap
Disorders affecting
blood–brain
barrier
Tubercular
meningitis
red blood cell (RBC) counts on all three tubes to measure decreasing or constant blood is not always reliable.2 Streaks of
blood also may be seen in specimens acquired following a traumatic procedure.
Clot Formation
Fluid collected from a traumatic tap may form clots owing to
the introduction of plasma fibrinogen into the specimen.
Bloody CSF caused by intracranial hemorrhage does not contain enough fibrinogen to clot. Diseases in which damage to
the blood–brain barrier allows increased filtration of protein
3920_Ch09_180-202 23/01/14 10:30 AM Page 185
Chapter 9 | Cerebrospinal Fluid
and coagulation factors also cause clot formation but do not
usually produce a bloody fluid. These conditions include
meningitis, Froin syndrome, and blocked CSF circulation
through the subarachnoid space. A classic web-like pellicle is
associated with tubercular meningitis and can be seen after
overnight refrigeration of the fluid.3
1
2
3
4
5
6
7
8
9
185
Xanthochromic Supernatant
RBCs must usually remain in the CSF for approximately
2 hours before noticeable hemolysis begins; therefore, a xanthochromic supernatant would be the result of blood that has
been present longer than that introduced by the traumatic tap.
Care should be taken, however, to consider this examination
in conjunction with those previously discussed, because a very
recent hemorrhage would produce a clear supernatant, and introduction of serum protein from a traumatic tap could also
cause the fluid to appear xanthochromic. To examine a bloody
fluid for the presence of xanthochromia, the fluid should be
centrifuged in a microhematocrit tube and the supernatant
examined against a white background.
Additional testing for differentiation includes microscopic
examination and the D-dimer test. The microscopic finding of
macrophages containing ingested RBCs (erythrophagocytosis)
or hemosiderin granules indicates intracranial hemorrhage.
Detection of the fibrin degradation product D-dimer by latex
agglutination immunoassay indicates fibrin formation at a
hemorrhage site.
Cell Count
The cell count that is routinely performed on CSF specimens
is the leukocyte (white blood cell [WBC]) count. As discussed
previously, the presence and significance of RBCs can usually
be ascertained from the appearance of the specimen. Therefore,
RBC counts are usually determined only when a traumatic tap
has occurred and a correction for leukocytes or protein is desired. The RBC count can be calculated by performing a total
cell count and a WBC count and subtracting the WBC count
from the total count, if necessary. Any cell count should be performed immediately, because WBCs (particularly granulocytes)
and RBCs begin to lyse within 1 hour, and 40% of the leukocytes disintegrate after 2 hours.4 Specimens that cannot be
analyzed immediately should be refrigerated.
Methodology
Normal adult CSF contains 0 to 5 WBCs/µ L. The number is
higher in children, and as many as 30 mononuclear cells/µ L
can be considered normal in newborns.5 Specimens that contain up to 200 WBCs or 400 RBCs/µ L may appear clear, so it
is necessary to examine all specimens microscopically.6 An improved Neubauer counting chamber (Fig. 9–5) is routinely
used for performing CSF cell counts. Traditionally, electronic
cell counters have not been used for performing CSF cell
counts, owing to high background counts and poor reproducibility of low counts.
Figure 9–5 Neubauer counting chamber depicting the nine large
square counting areas.
Automation increases precision, standardization, and
faster turnaround time for results. Various automated instruments such as the ADVIA 2120i (Siemens Healthcare Diagnostics Incorporated, Deerfield, IL), Sysmex XE-5000 (Sysmex
Corporation, Mundelein, IL), Iris iQ200 with Body Fluids
Module (Iris Diagnostics, Chatsworth, CA), and the Beckman
Coulter LH780 and UniCel DxH800 (Beckman Coulter, Inc.)
are available for CSF cells counts. See Appendix A for more
information on automated body fluid analyzers.
Calculating CSF Cell Counts
The standard Neubauer calculation formula used for blood cell
counts is also applied to CSF cell counts to determine the number of cells per microliter.
Number of cells counted × dilution
= cells/µ L
Number of cells counted × volume of 1 square
This formula can be used for both diluted and undiluted
specimens and offers flexibility in the number and size of the
squares counted. Many varied calculations are available, including condensations of the formula to provide single factors
by which to multiply the cell count. Keep in mind that the purpose of any calculation is to convert the number of cells
counted in a specific amount of fluid to the number of cells
that would be present in 1 µ L of fluid. Therefore, a factor can
be used only when the dilution and counting area are specific
for that factor.
The methodology presented in this chapter eliminates
the need to correct for the volume counted by counting the
four large corner squares (0.4 µ L) and the large center square
(0.1 µ L) on each side of the counting chamber.7
3920_Ch09_180-202 23/01/14 10:30 AM Page 186
186
Part Three | Other Body Fluids
EXAMPLE
Number of cells counted × dilution ×
1µ L
= cells/µ L
1 µ L (0.1 × 10)
(volume counted)
Total Cell Count
Clear specimens may be counted undiluted, provided no overlapping of cells is seen during the microscopic examination.
When dilutions are required, calibrated automatic pipettes, not
mouth pipetting, are used. Dilutions for total cell counts are
made with normal saline, mixed by inversion, and loaded into
the hemocytometer with a Pasteur pipette. Cells are counted
in the four corner squares and the center square on both sides
of the hemocytometer. As shown in the preceding example,
the number of cells counted multiplied by the dilution factor
equals the number of cells per microliter.
WBC Count
Lysis of RBCs must be obtained before performing the WBC
count on either diluted or undiluted specimens. Specimens
requiring dilution can be diluted in the manner described
previously, substituting 3% glacial acetic acid to lyse the
RBCs. Adding methylene blue to the diluting fluid stains the
WBCs, providing better differentiation between neutrophils
and mononuclear cells.
To prepare a clear specimen that does not require dilution
for counting, place four drops of mixed specimen in a clean
tube. Rinse a Pasteur pipette with 3% glacial acetic acid, draining thoroughly, and draw the four drops of CSF into the rinsed
pipette. Allow the pipette to sit for 1 minute, mix the solution
in the pipette, discard the first drop, and load the hemocytometer. As in the total cell count, WBCs are counted in the
four corner squares, and the center square on both sides of the
hemocytometer and the number is multiplied by the dilution
factor to obtain the number of WBCs per microliter. If a different number of squares is counted, use the standard Neubauer
formula to obtain the number of cells per microliter.
Quality Control of CSF and Other Body
Fluid Cell Counts
Liquid commercial controls for spinal fluid RBC and WBC
counts are available from several manufacturers. They can be
purchased at two levels of concentration. In-house controls can
also be prepared.
All diluents should be checked biweekly for contamination by examining them in a counting chamber under 400×
magnification. Contaminated diluents should be discarded and
new solutions prepared. The speed of the cytocentrifuge
should be checked monthly with a tachometer, and the timing
should be checked with a stopwatch.
If nondisposable counting chambers are used, they must
be soaked in a bactericidal solution for at least 15 minutes and
then thoroughly rinsed with water and cleaned with isopropyl
alcohol after each use.
Differential Count on a
CSF Specimen
Identifying the type or types of cells present in the CSF is a
valuable diagnostic aid. The differential count should be performed on a stained smear and not from the cells in the
counting chamber. Poor visualization of the cells as they appear in the counting chamber has led to the laboratory practice of reporting only the percentage of mononuclear and
polynuclear cells present, which can result in overlooking
abnormal cells with considerable diagnostic importance. To
ensure that the maximum number of cells is available for examination, the specimen should be concentrated before
preparing the smear.
Methods available for specimen concentration include
sedimentation, filtration, centrifugation, and cytocentrifugation. Sedimentation and filtration are not routinely used in the
clinical laboratory, although they do produce less cellular distortion. Most laboratories that do not have a cytocentrifuge
concentrate specimens with routine centrifugation. The specimen is centrifuged for 5 to 10 minutes, supernatant fluid is
removed and saved for additional tests, and slides made from
the suspended sediment are allowed to air dry and are stained
with Wright’s stain. When the differential count is performed,
100 cells should be counted, classified, and reported in terms
of percentage. If the cell count is low and finding 100 cells is
not possible, report only the numbers of the cell types seen.
Cytocentrifugation
A diagrammatic view of the principle of cytocentrifugation is
shown in Figure 9–6. Fluid is added to the conical chamber,
and as the specimen is centrifuged, cells present in the fluid
are forced into a monolayer within a 6-mm diameter circle on
the slide. Fluid is absorbed by the filter paper blotter, producing a more concentrated area of cells. As little as 0.1 mL of CSF
combined with one drop of 30% albumin produces an adequate cell yield when processed with the cytocentrifuge.
Adding albumin increases the cell yield and decreases the
cellular distortion frequently seen on cytocentrifuged specimens. Positively charged coated slides to attract cells (Shandon,
Inc, Pittsburgh, PA) are also available. Cellular distortion may
include cytoplasmic vacuoles, nuclear clefting, prominent nucleoli, indistinct nuclear and cytoplasmic borders, and cellular
clumping that resembles malignancy. Cells from both the center and periphery of the slide should be examined because
cellular characteristics may vary between areas of the slide.
A daily control slide for bacteria should also be prepared
using 0.2 mL saline and two drops of the 30% albumin currently being used. The slide is stained and examined if bacteria
are seen on a patient’s slide.
Table 9–2 presents a cytocentrifuge recovery chart for
comparison with chamber counts. The chamber count should
3920_Ch09_180-202 23/01/14 10:30 AM Page 187
Chapter 9 | Cerebrospinal Fluid
Stainless
steel
Cytoclip
slide clip
187
Completed assembly
Cytoslide™
microscope
slide
Cytofunnel™ disposable
sample chamber with
attached filter card
In-load position
In operation
Figure 9–7 Normal lymphocytes. Some cytocentrifuge distortion of
cytoplasm (×1000).
This cutaway drawing illustrates, at left, the in-load position which
shows the sample chamber assembly in a tilted-back position, so
that the sample is not absorbed by the filter card. During spinning,
centrifugal force tilts the assembly upright and forces the sample to
flow toward the microscope slide.
Figure 9–6 Cytospin 3 cytocentrifuge specimen processing assembly
(Courtesy of Shandon, Inc., Pittsburgh, PA).
be repeated if too many cells are seen on the slide, and a new
slide should be prepared if not enough cells are seen on the
slide.7
CSF Cellular Constituents
The cells found in normal CSF are primarily lymphocytes and
monocytes (Figs. 9–7 and 9–8). Adults usually have a predominance of lymphocytes to monocytes (70:30), whereas the
ratio is essentially reversed in children.5 Improved concentration methods are also showing occasional neutrophils in normal CSF.8 The presence of increased numbers of these normal
cells (termed pleocytosis) is considered abnormal, as is the
finding of immature leukocytes, eosinophils, plasma cells,
macrophages, increased tissue cells, and malignant cells.
Table 9–2
Cytocentrifuge Recovery Chart7
Number of WBCs
Counted in Chamber
0
1–5
6–10
11–20
20
Number of Cells on
Cytocentrifuge Slide
0–40
20–100
60–150
150–250
250
Figure 9–8 Normal lymphocytes and monocytes (×500).
When pleocytosis involving neutrophils, lymphocytes, or
monocytes is present, the CSF differential count is most frequently associated with its role in providing diagnostic information about the type of microorganism that is causing an
infection of the meninges (meningitis). A high CSF WBC count
of which the majority of the cells are neutrophils is considered
indicative of bacterial meningitis. Likewise, a moderately elevated CSF WBC count with a high percentage of lymphocytes
and monocytes suggests meningitis of viral, tubercular, fungal,
or parasitic origin.
As seen in Table 9–3, many pathologic conditions other
than meningitis can be associated with abnormal cells in the
CSF. Therefore, because laboratory personnel become so accustomed to finding neutrophils, lymphocytes, and monocytes, they should be careful not to overlook other types of
cells. Cell forms differing from those found in blood include
macrophages, choroid plexus and ependymal cells, spindleshaped cells, and malignant cells.
Neutrophils
In addition to bacterial meningitis, increased neutrophils
also are seen in the early stages (1 to 2 days) of viral, fungal,
tubercular, and parasitic meningitis. Neutrophils may also
3920_Ch09_180-202 23/01/14 10:30 AM Page 188
188
Part Three | Other Body Fluids
Table 9–3
Predominant Cells Seen in CSF
Type of Cell
Major Clinical Significance
Microscopic Findings
Lymphocytes
Normal
Viral, tubercular, and fungal meningitis
Multiple sclerosis
Bacterial meningitis
Early cases of viral, tubercular, and
fungal meningitis
Cerebral hemorrhage
Normal
Viral, tubercular, and fungal meningitis
Multiple sclerosis
RBCs in spinal fluid
All stages of development may be found
Neutrophils
Monocytes
Macrophages
Blast forms
Lymphoma cells
Plasma cells
Ependymal, choroidal,
and spindle-shaped
cells
Malignant cells
Acute leukemia
Disseminated lymphomas
Multiple sclerosis
Lymphocyte reactions
Diagnostic procedures
Metastatic carcinomas
Primary central nervous system carcinoma
Granules may be less prominent than in blood
Cells disintegrate rapidly
Found mixed with lymphocytes
May contain phagocytized RBCs appearing as empty
vacuoles or ghost cells, hemosiderin granules, and
hematoidin crystals
Lymphoblasts, myeloblasts, or monoblasts
Resemble lymphocytes with cleft nuclei
Traditional and classic forms seen
Reactive lymphs
Seen in clusters with distinct nuclei and distinct cell
walls
Seen in clusters with fusing of cell borders and nuclei
contain cytoplasmic vacuoles following cytocentrifugation
(Fig. 9–9). Granules are also lost more rapidly in CSF. Neutrophils associated with bacterial meningitis may contain
phagocytized bacteria (Figs. 9–10 and 9–11). Although of
little clinical significance, neutrophils may be increased following central nervous system (CNS) hemorrhage, repeated
lumbar punctures, and injection of medications or radiographic dye.
Neutrophils with pyknotic nuclei indicate degenerating
cells. They may resemble nucleated red blood cells (NRBCs)
but usually have multiple nuclei. When a single nucleus is
present they can appear similar to NRBCs (Fig. 9–12). NRBCs
are seen as a result of bone marrow contamination during the
spinal tap (Figs. 9–13 and 9–14). This is found in approximately 1% of specimens.9 Capillary structures and endothelial
cells may be seen following a traumatic tap (Fig. 9–15).
Figure 9–9 Neutrophils with cytoplasmic vacuoles resulting from
cytocentrifugation (×500).
Figure 9–10 Neutrophils with intracellular bacteria (×1000).
3920_Ch09_180-202 23/01/14 10:30 AM Page 189
Chapter 9 | Cerebrospinal Fluid
Figure 9–11 Neutrophils with intracellular and extracellular bacteria
(×1000).
Figure 9–12 Neutrophils with pyknotic nuclei. Notice the cell with a
single nucleus in the center (×1000).
189
Figure 9–14 Bone marrow contamination (×1000). Notice the immature RBCs and granulocytes.
Figure 9–15 Capillary and tissue fragments from a traumatic tap
(×100).
conjunction with normal cells (Fig. 9–16). Increased lymphocytes are seen in cases of both asymptomatic HIV infection
and AIDS. A moderately elevated WBC count (less than
50 WBCs/µ L) with increased normal and reactive lymphocytes
and plasma cells may indicate multiple sclerosis or other degenerative neurologic disorders.10
Figure 9–13 Nucleated RBCs seen with bone marrow contamination
(×1000).
Lymphocytes and Monocytes
A mixture of lymphocytes and monocytes is common in cases
of viral, tubercular, and fungal meningitis. Reactive lymphocytes containing increased dark blue cytoplasm and clumped
chromatin are frequently present during viral infections in
Figure 9–16 Broad spectrum of lymphocytes and monocytes in viral
meningitis (×1000).
3920_Ch09_180-202 23/01/14 10:30 AM Page 190
190
Part Three | Other Body Fluids
Eosinophils
Increased eosinophils are seen in the CSF in association with
parasitic infections, fungal infections (primarily Coccidioides immitis), and introduction of foreign material, including medications and shunts, into the CNS (Fig. 9–17).
Macrophages
The purpose of macrophages in the CSF is to remove cellular
debris and foreign objects such as RBCs. Macrophages appear
within 2 to 4 hours after RBCs enter the CSF and are frequently
seen following repeated taps. They tend to have more cytoplasm
than monocytes in the peripheral blood (PB) (Fig. 9–18).
The finding of increased macrophages indicates a previous
hemorrhage (Fig. 9–19). Further degradation of the phagocytized RBCs results in the appearance of dark blue or black ironcontaining hemosiderin granules (Figs. 9–20 through 9–23).
Yellow hematoidin crystals represent further degeneration.
They are iron-free, consisting of hemoglobin and unconjugated
bilirubin (Figs. 9–24 and 9–25).
Figure 9–19 Macrophages showing erythrophagocytosis (×500).
Nonpathologically Significant Cells
Nonpathologically significant cells are most frequently seen
after diagnostic procedures such as pneumoencephalography
Figure 9–20 Macrophage with RBC remnants (×500).
Figure 9–17 Eosinophils (×1000). Notice cytocentrifuge distortion.
Figure 9–21 Macrophage with aggregated hemosiderin granules
(×500).
Figure 9–18 Macrophages. Notice the large amount of cytoplasm
and vacuoles (×500).
and in fluid obtained from ventricular taps or during neurosurgery. The cells often appear in clusters and can be distinguished from malignant cells by their uniform appearance.
Choroidal cells are from the epithelial lining of the
choroid plexus. They are seen singularly and in clumps. Nucleoli are usually absent and nuclei have a uniform appearance
(Fig. 9–26).
3920_Ch09_180-202 23/01/14 10:30 AM Page 191
Chapter 9 | Cerebrospinal Fluid
191
Figure 9–22 Macrophage containing hemosiderin stained with
Prussian blue (×250).
Figure 9–25 Macrophages with hemosiderin and hematoidin (×250).
Notice the bright yellow color.
Figure 9–23 Macrophage with coarse hemosiderin granules (×500).
Figure 9–26 Choroidal cells showing distinct cell borders and nuclear
uniformity (×500).
Figure 9–24 Macrophage containing hemosiderin and hematoidin
crystals (×500).
Figure 9–27 Ependymal cells. Notice the nucleoli and less distinct
cell borders (×1000).
Ependymal cells are from the lining of the ventricles and
neural canal. They have less defined cell membranes and are frequently seen in clusters. Nucleoli are often present (Fig. 9–27).
Spindle-shaped cells represent lining cells from the arachnoid. They are usually seen in clusters and may be seen with
systemic malignancies (Fig. 9–28).
Malignant Cells of Hematologic Origin
Lymphoblasts, myeloblasts, and monoblasts (Figs. 9–29 to
9–31) in the CSF are frequently seen as a serious complication
of acute leukemias. Nucleoli are often more prominent than in
blood smears.
3920_Ch09_180-202 23/01/14 10:30 AM Page 192
192
Part Three | Other Body Fluids
Figure 9–28 Cluster of spindle-shaped cells (×500).
Figure 9–31 Monoblasts and two lymphocytes (×1000). Notice the
prominent nucleoli.
Figure 9–29 Lymphoblasts from acute lymphocytic leukemia
(×500).
Figure 9–32 Cleaved and noncleaved lymphoma cells (×1000).
Figure 9–30 Myeloblasts from acute myelocytic leukemia (×500).
Figure 9–33 Lymphoma cells with nucleoli (×500).
Lymphoma cells are also seen in the CSF and indicate dissemination from the lymphoid tissue. They resemble large and
small lymphocytes and usually appear in clusters of large,
small, or mixed cells based on the classification of the lymphoma. Nuclei may appear cleaved, and prominent nucleoli
are present (Figs. 9–32 to 9–34).
Malignant Cells of Nonhematologic Origin
Metastatic carcinoma cells of nonhematologic origin are primarily from lung, breast, renal, and gastrointestinal malignancies. Cells from primary CNS tumors include astrocytomas,
retinoblastomas, and medulloblastomas (Fig. 9–35). They
usually appear in clusters and must be distinguished from
3920_Ch09_180-202 23/01/14 10:30 AM Page 193
Chapter 9 | Cerebrospinal Fluid
193
Cerebrospinal Protein
Figure 9–34 Burkitt lymphoma. Notice characteristic vacuoles
(×500).
The most frequently performed chemical test on CSF is the
protein determination. Normal CSF contains a very small
amount of protein. Reference values for total CSF protein are
usually listed as 15 to 45 mg/dL, but are somewhat method
dependent, and higher values are found in infants and people
over age 40.11 This value is reported in milligrams per
deciliter and not grams per deciliter, as are plasma protein
concentrations.
In general, the CSF contains protein fractions similar
to those found in serum; however, the ratio of CSF proteins to
serum proteins varies among the fractions. As in serum, albumin makes up most of CSF protein. But in contrast to serum,
prealbumin is the second most prevalent fraction in CSF. The
alpha globulins include primarily haptoglobin and ceruloplasmin. Transferrin is the major beta globulin present; also, a separate carbohydrate-deficient transferrin fraction, referred to as
“tau,” is seen in CSF and not in serum. CSF gamma globulin
is primarily immunoglobulin G (IgG), with only a small
amount of immunoglobulin A (IgA). Immunoglobulin M
(IgM), fibrinogen, and beta lipoprotein are not found in
normal CSF.12
Clinical Significance of Elevated Protein Values
Figure 9–35 Medulloblastoma (×1000). Notice cellular clustering,
nuclear irregularities, and rosette formation.
normal clusters of ependymal, choroid plexus, lymphoma, and
leukemia cells. Fusing of cell walls and nuclear irregularities
and hyperchromatic nucleoli are seen in clusters of malignant
cells. Slides containing abnormal cells must be referred to
pathology.
Chemistry Tests
Because CSF is formed by filtration of the plasma, one would
expect to find the same low-molecular-weight chemicals in
the CSF that are found in the plasma. This is essentially true;
however, because the filtration process is selective and the
chemical composition is controlled by the blood–brain barrier,
reference values for CSF chemicals are not the same as the
plasma values. Abnormal values result from alterations in
the permeability of the blood–brain barrier or increased production or metabolism by the neural cells in response to a
pathologic condition. They seldom have the same diagnostic
significance as plasma abnormalities. The clinically important
CSF chemicals are few; under certain conditions it may be
necessary to measure a larger variety.
Elevated total protein values are most frequently seen in pathologic conditions. Abnormally low values are present when fluid
is leaking from the CNS. The causes of elevated CSF protein
include damage to the blood–brain barrier, immunoglobulin
production within the CNS, decreased normal protein clearance from the fluid, and neural tissue degeneration. Meningitis
and hemorrhage conditions that damage the blood–brain
barrier are the most common causes of elevated CSF protein.
Many other neurologic disorders can elevate the CSF protein,
and finding an abnormal result on clear fluid with a low cell
count is not unusual (Table 9–4).
Methodology
The two most routinely used techniques for measuring total
CSF protein use the principles of turbidity production or dyebinding ability. The turbidity method has been adapted to automated instrumentation in the form of nephelometry.
Methods for measuring CSF protein are available for most automated chemistry analyzers.
Protein Fractions
Routine CSF protein procedures are designed to measure total
protein concentration. However, diagnosis of neurologic disorders associated with abnormal CSF protein often requires
measurement of the individual protein fractions. Protein that
appears in the CSF as a result of damage to the integrity of the
blood–brain barrier contains fractions proportional to those
in plasma, with albumin present in the highest concentration.
Diseases, including multiple sclerosis, that stimulate the
immunocompetent cells in the CNS show a higher proportion
of IgG.
3920_Ch09_180-202 23/01/14 10:30 AM Page 194
194
Part Three | Other Body Fluids
Table 9–4
Clinical Causes of Abnormal CSF Protein
Values*
Elevated Results
• Meningitis
• Hemorrhage
• Primary CNS tumors
• Multiple sclerosis
• Guillain-Barré syndrome
• Neurosyphilis
• Polyneuritis
Decreased Results
• Myxedema
• Cushing disease
• Connective tissue
disease
• Polyneuritis
• Diabetes
• Uremia
• CSF leakage/trauma
• Recent puncture
• Rapid CSF production
• Water intoxication
* Reference values for protein are usually 15 to 45 mg/dL, but are
method dependent, and higher values are found in infants and
people older than 40 years.
To accurately determine whether IgG is increased because it is being produced within the CNS or is elevated
as the result of a defect in the blood–brain barrier, comparisons between serum and CSF levels of albumin and
IgG must be made. Methods include the CSF/serum albumin index to evaluate the integrity of the blood–brain barrier and the CSF IgG index to measure IgG synthesis within
the CNS.
The CSF/serum albumin index is calculated after determining the concentration of CSF albumin in milligrams per
deciliter and the serum concentration in grams per deciliter.
The formula used is as follows:
CSF/serum albumin index =
Electrophoresis and Immunophoretic Techniques
The primary purpose for performing CSF protein electrophoresis is to detect oligoclonal bands, which represent inflammation within the CNS. The bands are located in the gamma
region of the protein electrophoresis, indicating immunoglobulin production. To ensure that the oligoclonal bands are present as the result of neurologic inflammation, simultaneous
serum electrophoresis must be performed. Disorders such as
leukemia, lymphoma, and viral infections may produce serum
banding, which can appear in the CSF as a result of blood–
brain barrier leakage or traumatic introduction of blood into
the CSF specimen. Banding representing both systemic and
neurologic involvement is seen in the serum and CSF with HIV
infection.14
The presence of two or more oligoclonal bands in the CSF
that are not present in the serum can be a valuable tool in diagnosing multiple sclerosis, particularly when accompanied
by an increased IgG index (Fig. 9–36). Other neurologic disorders including encephalitis, neurosyphilis, Guillain-Barré
syndrome, and neoplastic disorders also produce oligoclonal
banding that may not be present in the serum. Therefore, the
presence of oligoclonal banding must be considered in conjunction with clinical symptoms. Oligoclonal banding remains
positive during remission of multiple sclerosis, but disappears
in other disorders.10
Low protein levels in the CSF make concentration of the
fluid before performing electrophoresis essential for most electrophoretic techniques. Better resolution can be obtained using
CSF immunofixation electrophoresis (IFE) and isoelectric
CSF albumin (mg/dL)
Serum albumin (g/dL)
An index value less than 9 represents an intact blood–
brain barrier. The index increases relative to the amount of
damage to the barrier.
Calculation of an IgG index, which is actually a comparison of the CSF/serum albumin index with the CSF/serum
IgG index, compensates for any IgG entering the CSF via the
blood–brain barrier.13 It is performed by dividing the
CSF/serum IgG index by the CSF/serum albumin index as
follows:
IgG index =
CSF IgG (mg/dL)/serum IgG (g/dL)
CSF albumin (mg/dL)/serum albumin (g/dL)
Normal IgG index values vary slightly among laboratories;
however, in general, values greater than 0.70 indicate IgG production within the CNS.
Techniques for measuring CSF albumin and globulin have
been adapted to automated instrumentation.
Figure 9–36 Normal and abnormal oligoclonal banding. (Photograph
courtesy of the University of Pittsburgh Department of Pathology, Case
Index files, Case 059; http://path.upmc.edu/cases/case59.html, with
permission.)
3920_Ch09_180-202 23/01/14 10:30 AM Page 195
Chapter 9 | Cerebrospinal Fluid
focusing (IEF) followed by silver staining. Specimen concentration is not required by the more sensitive IEF procedure.
These techniques are also the method of choice when determining whether a fluid is actually CSF. CSF can be identified
based on the appearance of the previously mentioned extra
isoform of tau transferrin that is found only in CSF.15
195
The presence of myelin basic protein (MBP) in the CSF indicates recent destruction of the myelin sheath that protects the
axons of the neurons (demyelination). The course of multiple
sclerosis can be monitored by measuring the amount of MBP
in the CSF.16 MBP may also provide a valuable measure of the
effectiveness of current and future treatments. Immunoassay
techniques are used for measurement.17
provides more reliable information when the initial diagnosis
is difficult. Levels greater than 35 mg/dL are frequently seen
with bacterial meningitis, whereas in viral meningitis, lactate
levels remain lower than 25 mg/dL. CSF lactate levels remain
elevated during initial treatment but fall rapidly when treatment is successful, thus offering a sensitive method for evaluating the effectiveness of antibiotic therapy.
Tissue destruction within the CNS owing to oxygen deprivation (hypoxia) increases CSF lactic acid levels. Therefore,
elevated CSF lactate is not limited to meningitis and can result
from any condition that decreases oxygen flow to the tissues.
CSF lactate levels are frequently used to monitor severe head
injuries. RBCs contain high concentrations of lactate, and
falsely elevated results may be obtained on xanthochromic or
hemolyzed fluid.8
CSF Glucose
CSF Glutamine
Glucose enters the CSF by selective transport across the blood–
brain barrier, which results in a reference value that is approximately 60% to 70% that of the plasma glucose. If the plasma
glucose is 100 mg/dL, then a reference CSF glucose would be
approximately 65 mg/dL. For an accurate evaluation of CSF
glucose, a blood glucose test must be run for comparison. The
blood glucose should be drawn about 2 hours before the spinal
tap to allow time for equilibration between the blood and fluid.
CSF glucose is analyzed using the same procedures employed
for blood glucose. Specimens should be tested immediately because glycolysis occurs rapidly in CSF.
The diagnostic significance of CSF glucose is confined
to finding values that are decreased relative to plasma values.
Elevated CSF glucose values are always a result of plasma
elevations. Low CSF glucose values can be of considerable
diagnostic value in determining the causative agents in meningitis. A markedly decreased CSF glucose level accompanied by
an increased WBC count and a large percentage of neutrophils
indicates bacterial meningitis. If the WBCs are lymphocytes
instead of neutrophils, tubercular meningitis is suspected.
Likewise, if a normal CSF glucose value is found with an increased number of lymphocytes, the diagnosis would favor
viral meningitis. Classic laboratory patterns such as those just
described may not be found in all cases of meningitis, but they
can be helpful when they appear.
Decreased CSF glucose values are caused primarily by
alterations in the mechanisms of glucose transport across the
blood–brain barrier and by increased use of glucose by the
brain cells. The common tendency to associate decreased
glucose totally with its use by microorganisms and leukocytes
cannot account for the variations in glucose concentrations
seen in different types of meningitis and the decreased levels
seen in other disorders producing damage to the CNS.18
Glutamine is produced from ammonia and α -ketoglutarate by
the brain cells. This process serves to remove the toxic metabolic waste product ammonia from the CNS. The normal concentration of glutamine in the CSF is 8 to 18 mg/dL.19 Elevated
levels are associated with liver disorders that result in increased
blood and CSF ammonia. Excess ammonia in the CNS increases glutamine synthesis; therefore, determining CSF glutamine provides an indirect test for the presence of excess
ammonia in the CSF. Several methods of assaying glutamine
are available and are based on the measurement of ammonia
liberated from the glutamine. This is preferred over the direct
measurement of CSF ammonia because the glutamine concentration remains more stable than the volatile ammonia concentration in the collected specimen. The CSF glutamine level also
correlates with clinical symptoms much better than does the
blood ammonia.19
As the concentration of ammonia in the CSF increases, the
supply of α -ketoglutarate becomes depleted; glutamine can no
longer be produced to remove the toxic ammonia, and coma
ensues. Some disturbance of consciousness is almost always
seen when glutamine levels are more than 35 mg/dL.12 Therefore, the CSF glutamine test is frequently requested for patients
with coma of unknown origin. Approximately 75% of children
with Reye syndrome have elevated CSF glutamine levels.20
A summary of CSF chemistry tests is presented in
Table 9–5.
Myelin Basic Protein
CSF Lactate
CSF lactate levels can be a valuable aid in diagnosing and
managing meningitis cases. In bacterial, tubercular, and fungal
meningitis, CSF lactate levels greater than 25 mg/dL occurs
much more consistently than does decreased glucose and
Microbiology Tests
The role of the microbiology laboratory in analyzing CSF is to
identify the causative agent in meningitis. For positive identification, the microorganism must be recovered from the fluid
by growing it on the appropriate culture medium. This can
take anywhere from 24 hours in cases of bacterial meningitis
to 6 weeks for tubercular meningitis. Consequently, in many
instances, the CSF culture is actually a confirmatory rather than
a diagnostic procedure. However, the microbiology laboratory
does have several methods available to provide information for
a preliminary diagnosis. These methods include the Gram
3920_Ch09_180-202 23/01/14 10:30 AM Page 196
196
Part Three | Other Body Fluids
Table 9–5
CSF Chemistry Tests
Chemical
Substance
Reference Concentration
Value, Normal CSF
Significance of Increased
Concentration
Significance of Decreased
Concentration
Protein
15 to 45 mg/dL
CSF leakage
Glucose
60% to 70% of plasma
concentration
10 to 24 mg/dL
8 to 18 mg/dL
Meningitis
Hemorrhage
Multiple sclerosis
None
Lactate
Glutamine
>35 mg/dL: Bacterial meningitis
>35 mg/dL: Some disturbance of
consciousness
stain, acid-fast stain, India ink preparation, and latex agglutination tests. In Table 9–6, laboratory tests used in the differential diagnosis of meningitis are compared.
Gram Stain
The Gram stain is routinely performed on CSF from all suspected cases of meningitis, although its value lies in detecting
bacterial and fungal organisms. All smears and cultures should
be performed on concentrated specimens because often only
a few organisms are present at the onset of the disease. The
CSF should be centrifuged at 1500 g for 15 minutes, and slides
and cultures should be prepared from the sediment.21 Use of
the cytocentrifuge provides a highly concentrated specimen for
Gram stains. Even when concentrated specimens are used, at
least a 10% chance exists that Gram stains and cultures will be
negative. Thus, blood cultures should be taken, because the
causative organism is often present in both the CSF and the
blood.8 A CSF Gram stain is one of the most difficult slides to
Table 9–6
Bacterial, tubercular, and fungal
meningitis
None
None
interpret because the number of organisms present is usually
small, and they can easily be overlooked, resulting in a falsenegative report. Also, false-positive reports can occur if precipitated stain or debris is mistaken for microorganisms.
Therefore, considerable care should be taken when interpreting
a Gram stain. Organisms most frequently encountered include
Streptococcus pneumoniae (gram-positive cocci), Haemophilus
influenzae (pleomorphic gram-negative rods), Escherichia coli
(gram-negative rods), and Neisseria meningitidis (gram-negative
cocci). The gram-positive cocci Streptococcus agalactiae and the
gram-positive rods Listeria monocytogenes may be encountered
in newborns.
Acid-fast or fluorescent antibody stains are not routinely
performed on specimens unless tubercular meningitis is suspected. Considering the length of time required to culture mycobacteria, a positive report from this smear is extremely
valuable.
Specimens from possible cases of fungal meningitis are
Gram stained and often have an India ink preparation performed
Major Laboratory Results for Differential Diagnosis of Meningitis
Bacterial
Viral
Tubercular
Fungal
Elevated WBC count
Neutrophils present
Elevated WBC count
Lymphocytes present
Marked protein elevation
Moderate protein
elevation
Normal glucose level
Elevated WBC count
Lymphocytes and monocytes
present
Moderate to marked protein
elevation
Decreased glucose level
Elevated WBC count
Lymphocytes and monocytes
present
Moderate to marked protein
elevation
Normal to decreased glucose level
Lactate level >25 mg/dL
Pellicle formation
Lactate level >25 mg/dL
Positive India ink with Cryptococcus
neoformans
Positive immunologic test for
C. neoformans
Markedly decreased
glucose level
Lactate level >35 mg/dL
Positive Gram stain and
bacterial antigen tests
Normal lactate level
3920_Ch09_180-202 23/01/14 10:30 AM Page 197
Chapter 9 | Cerebrospinal Fluid
on them to detect the presence of thickly encapsulated Cryptococcus neoformans (Fig. 9–37). As one of the more frequently occurring complications of AIDS, cryptococcal meningitis is now
commonly encountered in the clinical laboratory. Particular attention should be paid to the Gram stain for the classic starburst
pattern produced by Cryptococcus, as this may be seen more
often than a positive India ink (Fig. 9–38).22
Latex agglutination tests to detect the presence of C. neoformans antigen in serum and CSF provide a more sensitive
method than the India ink preparation. However, immunologic testing results should be confirmed by culture and
demonstration of the organisms by India ink, because falsepositive reactions do occur. Interference by rheumatoid factor
is the most common cause of false-positive reactions.22 Several
commercial kits with pretreatment techniques are available
and include incubation with dithiothreitol or pronase and
boiling with ethylenediaminetetra-acetic acid.23,24 An enzyme
immunoassay technique has been shown to produce fewer
false-positive results.
The lateral flow assay (LAF) can provide a rapid method
for detecting C. neoformans. The procedure utilizes a reagent
strip coated with monoclonal antibodies that react with the
197
cryptococcal polysaccharide capsule.25 The complete article and
procedures images are available at http:// www.mlo-online.com/
201303ci.
Latex agglutination and enzyme-linked immunosorbent
assay (ELISA) methods provide a rapid means for detecting and
identifying microorganisms in CSF. Test kits are available to detect Streptococcus group B, H. influenzae Type B, S. pneumoniae,
N. meningitidis A, B, C, Y, W135, Mycobacterium tuberculosis,
Coccidioides immitis, and E. coli K1 antigens. The bacterial antigen
test (BAT) does not appear to be as sensitive to N. meningitidis
as it is to the other organisms. The BAT should be used in combination with results from the hematology and clinical chemistry
laboratories for diagnosing meningitis.26 The Gram stain is still
the recommended method for detecting organisms.27
The amoeba Naegleria fowleri is an opportunistic parasite
found in ponds, small lakes, and even chlorinated swimming
pools. The Naegleria enters the nasal passages and migrates
along the olfactory nerves to invade the brain. Motile trophozoites can be observed microscopically by examining a wet
preparation of CSF. Nonmotile trophozoites may be seen on
cytocentrifuged stained smears accompanied by increased
WBCs and no bacteria. Figure 9–39 shows a Naegleria trophozoite. Notice the elongated form with a tapered posterior.28
Serologic Testing
Figure 9–37 India ink preparation of C. neoformans (×400). Notice
budding yeast form. (Courtesy of Ann K. Fulenwider, MD.)
Figure 9–38 Gram stain of C. neoformans showing starburst pattern
(×1000). (Courtesy of Ann K. Fulenwider, MD.)
In addition to the serologic procedures performed for identification of microorganisms, serologic testing of the CSF is performed to detect the presence of neurosyphilis. The use of
penicillin in the early stages of syphilis has greatly reduced the
number of neurosyphilis cases. Consequently, the number of
requests for serologic tests for syphilis on CSF is currently low.
However, detecting the antibodies associated with syphilis in
the CSF still remains a necessary diagnostic procedure.
Although many different serologic tests for syphilis are
available when testing blood, the procedure recommended by
the CDC to diagnose neurosyphilis is the Venereal Disease Research Laboratories (VDRL), even though it is not as sensitive
as the fluorescent treponemal antibody-absorption (FTA-ABS)
test for syphilis. The rapid plasma regain (RPR) test is not recommended because it is less sensitive than the VDRL. If the
FTA-ABS is used, care must be taken to prevent contamination
with blood, because the FTA-ABS remains positive in the
serum of treated cases of syphilis.29
Methodology for preparing a simulated CSF for student
laboratory testing is included in the Instructor’s Guide that accompanies this textbook.30,31
Figure 9–39 Naegleria fowleri trophozoite. (From Leventhal & Cheadle,
Medical Parasitology, 6th ed., 2012, FA Davis Company, Philadelphia,
with permission.)
3920_Ch09_180-202 23/01/14 10:30 AM Page 198
198
Part Three | Other Body Fluids
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Scanlon,VC and Sanders,T: Essentials of Anatomy and Physiology, 5th ed. FA Davis Company, Philadelphia, 2007.
2. Edlow, JA, and Caplan, LR: Avoiding pitfalls in the diagnosis of
subarachnoid hemorrhage. N Engl J Med 342:29–36, 2000.
3. Nagda, KK: Procoagulant activity of cerebrospinal fluid in
health and disease. Indian J Med Res 74:107–110, 1981.
4. Chow, G, and Schmidley, JW: Lysis of erythrocytes and leukocytes
in traumatic lumbar punctures. Arch Neurol 41:1084–1085, 1984.
5. Seehusen, DA, Reeves, MM, and Fomin, DA: Cerebrospinal
fluid analysis. Am Fam Physician 68(6):1103–1108, 2003.
6. Glasser, L: Tapping the wealth of information in CSF. Diagn
Med 4(1):23–33, 1981.
7. University of Virginia Health Sciences Center: Clinical Laboratory Procedure Manual. Charlottesville, VA, 1993.
8. Kjeldsberg, CR, and Knight, JA: Body Fluids: Laboratory Examination of Amniotic, Cerebrospinal, Seminal, Serous and Synovial Fluids: A Textbook Atlas. ASCP, Chicago, 1993.
9. Abrams, J, and Schumacher, HR: Bone marrow in cerebrospinal
fluid and possible confusion with malignancy. Arch Pathol Lab
Med 110:366–369, 1986.
10. Bentz, JS: Laboratory investigation of multiple sclerosis. Lab
Med 26(6):393–399, 1995.
11. Biou, D, et al: Cerebrospinal fluid protein concentrations in
children: Age-related values in patients without disorders of the
central nervous system. Clin Chem 46(3):399–403, 2000.
12. Fishman, RA: Cerebrospinal Fluid in Diseases of the Nervous
System, ed 2. WB Saunders, Philadelphia, 1992.
13. Hershey, LA, and Trotter, JL: The use and abuse of the cerebrospinal fluid IgG profile in the adult: A practical evaluation.
Ann Neurol 8(4):426–434, 1980.
14. Grimaldi, LME, et al: Oligoclonal IgG bands in cerebrospinal
fluid and serum during asymptomatic human immunodeficiency virus infection. Ann Neurol 24:277–279, 1988.
15. Rouah, E, Rogers, BB, and Buffone, GJ: Transferrin analysis by
immunofixation as an aid in the diagnosis of cerebrospinal fluid
otorrhea. Arch Pathol Lab Med 111:756–757, 1987.
16. Whitaker, JN: Myelin basic protein in cerebrospinal fluid and
other body fluids. Multiple Sclerosis 4(1):16–21, 1998.
17. Okta, M, et al: Evaluation of an enzyme immunoassay for
myelin basic protein in CSF. Clin Chem 46:1326–1330, 2000.
18. Menkes, J: The causes of low spinal fluid sugar in bacterial
meningitis: Another look. Pediatrics 44(1):1–3, 1969.
19. Hourani, BT, Hamlin, EM, and Reynolds, TB: Cerebrospinal
fluid glutamine as a measure of hepatic encephalopathy. Arch
Intern Med 127:1033–1036, 1971.
20. Glasgow, AM, and Dhiensiri, K: Improved assay for spinal fluid
glutamine and values for children with Reye’s syndrome. Clin
Chem 20(6):642–644, 1974.
21. Murray, PR, and Hampton, CM: Recovery of pathogenic bacteria from cerebrospinal fluid. J Clin Microbiol 12:554–557,
1980.
22. Sato, Y, et al: Rapid diagnosis of cryptococcal meningitis by
microscopic examination of centrifuged cerebrospinal fluid
sediment. J Neurol Sci 164(1):72–75, 1999.
23. Eng, RHK, and Person, A: Serum cryptococcal antigen determination in the presence of rheumatoid factor. J Clin Microbiol
14:700–702, 1981.
24. Stockman, L, and Roberts, GD: Specificity of the latex test for
cryptococcal antigen: A rapid simple method for eliminating
interference. J Clin Microbiol 17(5):945–947, 1983.
25. Knight, FR: New enzyme immunoassay for detecting cryptococcal antigen. J Clin Pathol 45(9):836–837, 1992.
26. Klausner, JD, Vijayan, T, Chiller,T: Sensitivity and specificity of
a new cryptococcal antigen lateral flow assay in serum and
cerebrospinal fluid. MLO, March 2013.
27. Wojewoda,C: Bacterial Antigen Testing, The Good, the Not So
Bad and the Ugly. NewsPath. Accessed February 14, 2013
28. Leventhal, R and Cheadle, RF: Medical Parasitology, ed.6,
FA Davis Company, Philadelphia, 2012.
29. Davis, LE, and Schmitt, JW: Clinical significance of cerebrospinal fluid tests for neurosyphilis. Ann Neurol 25:50–53,
1989.
30. Albright, RE, et al: Issues in cerebrospinal fluid management.
Am J Clin Pathol 95(3):397–401, 1991.
31. Lofsness, KG, and Jensen, TL: The preparation of simulated
spinal fluid for teaching purposes. Am J Med Technology
49(7):493–496, 1983.
Study Questions
1. The functions of the CSF include all of the following
except:
A. Removing metabolic wastes
B. Producing an ultrafiltrate of plasma
C. Supplying nutrients to the CNS
D. Protecting the brain and spinal cord
2. The CSF flows through the:
A. Choroid plexus
B. Pia mater
C. Arachnoid space
D. Dura mater
3. Substances present in the CSF are controlled by the:
A. Arachnoid granulations
B. Blood–brain barrier
C. Presence of one-way valves
D. Blood–CSF barrier
4. What department is the CSF tube labeled 3 routinely
sent to?
A. Hematology
B. Chemistry
C. Microbiology
D. Serology
3920_Ch09_180-202 23/01/14 10:30 AM Page 199
Chapter 9 | Cerebrospinal Fluid
5. The CSF tube that should be kept at room temperature is:
A. Tube 1
B. Tube 2
C. Tube 3
D. Tube 4
6. Place the appropriate letter in front of the statement that
best describes CSF specimens in these two conditions:
A. Traumatic tap
B. Intracranial hemorrhage
____ Even distribution of blood in all tubes
____ Xanthochromic supernatant
____ Concentration of blood in tube 1 is greater
than in tube 3
____ Specimen contains clots
7. The presence of xanthochromia can be caused by all of
the following except:
A. Immature liver function
B. RBC degradation
C. A recent hemorrhage
D. Elevated CSF protein
8. A web-like pellicle in a refrigerated CSF specimen
indicates:
A. Tubercular meningitis
B. Multiple sclerosis
C. Primary CNS malignancy
D. Viral meningitis
9. Given the following information, calculate the CSF WBC
count: cells counted, 80; dilution, 1:10; large Neubauer
squares counted, 10.
A. 8
B. 80
C. 800
D. 8000
10. A CSF WBC count is diluted with:
A. Distilled water
B. Normal saline
C. Acetic acid
D. Hypotonic saline
11. A total CSF cell count on a clear fluid should be:
A. Reported as normal
B. Not reported
C. Diluted with normal saline
D. Counted undiluted
199
12. The purpose of adding albumin to CSF before cytocentrifugation is to:
A. Increase the cell yield
B. Decrease the cellular distortion
C. Improve the cellular staining
D. Both A and B
13. The primary concern when pleocytosis of neutrophils and
lymphocytes is found in the CSF is:
A. Meningitis
B. CNS malignancy
C. Multiple sclerosis
D. Hemorrhage
14. Neutrophils with pyknotic nuclei may be mistaken for:
A. Lymphocytes
B. Nucleated RBCs
C. Malignant cells
D. Spindle-shaped cells
15. The presence of which of the following cells is increased
in a parasitic infection?
A. Neutrophils
B. Macrophages
C. Eosinophils
D. Lymphocytes
16. Macrophages appear in the CSF after:
A. Hemorrhage
B. Repeated spinal taps
C. Diagnostic procedures
D. All of the above
17. Nucleated RBCs are seen in the CSF as a result of:
A. Elevated blood RBCs
B. Treatment of anemia
C. Severe hemorrhage
D. Bone marrow contamination
18. After a CNS diagnostic procedure, which of the following
might be seen in the CSF?
A. Choroidal cells
B. Ependymal cells
C. Spindle-shaped cells
D. All of the above
3920_Ch09_180-202 23/01/14 10:30 AM Page 200
200
Part Three | Other Body Fluids
19. Hemosiderin granules and hematoidin crystals are seen in:
A. Lymphocytes
B. Macrophages
C. Ependymal cells
D. Neutrophils
20. Myeloblasts are seen in the CSF:
A. In bacterial infections
B. In conjunction with CNS malignancy
C. After cerebral hemorrhage
D. As a complication of acute leukemia
21. Cells resembling large and small lymphocytes with
cleaved nuclei represent:
A. Lymphoma cells
B. Choroid cells
C. Melanoma cells
D. Medulloblastoma cells
22. The reference range for CSF protein is:
A. 6 to 8 g/dL
B. 15 to 45 g/dL
C. 6 to 8 mg/dL
D. 15 to 45 mg/dL
23. CSF can be differentiated from serum by the presence of:
A. Albumin
B. Globulin
C. Prealbumin
D. Tau transferrin
24. In serum, the second most prevalent protein is IgG; in
CSF, the second most prevalent protein is:
A. Transferrin
B. Prealbumin
C. IgA
D. Ceruloplasmin
25. Elevated CSF protein values can be caused by all of the
following except:
A. Meningitis
B. Multiple sclerosis
C. Fluid leakage
D. CNS malignancy
26. The integrity of the blood–brain barrier is measured using
the:
A. CSF/serum albumin index
B. CSF/serum globulin ratio
C. CSF albumin index
D. CSF IgG index
27. Given the following results, calculate the IgG index: CSF IgG,
50 mg/dL; serum IgG, 2 g/dL; CSF albumin, 70 mg/dL;
serum albumin, 5 g/dL.
A. 0.6
B. 6.0
C. 1.8
D. 2.8
28. The CSF IgG index calculated in Study Question 27
indicates:
A. Synthesis of IgG in the CNS
B. Damage to the blood–brain barrier
C. Cerebral hemorrhage
D. Lymphoma infiltration
29. The finding of oligoclonal bands in the CSF and not in
the serum is seen with:
A. Multiple myeloma
B. CNS malignancy
C. Multiple sclerosis
D. Viral infections
30. A CSF glucose of 15 mg/dL, WBC count of 5000,
90% neutrophils, and protein of 80 mg/dL suggests:
A. Fungal meningitis
B. Viral meningitis
C. Tubercular meningitis
D. Bacterial meningitis
31. A patient with a blood glucose of 120 mg/dL would have
a normal CSF glucose of:
A. 20 mg/dL
B. 60 mg/dL
C. 80 mg/dL
D. 120 mg/dL
32. CSF lactate will be more consistently decreased in:
A. Bacterial meningitis
B. Viral meningitis
C. Fungal meningitis
D. Tubercular meningitis
33. Measurement of which of the following can be replaced by
CSF glutamine analysis in children with Reye syndrome?
A. Ammonia
B. Lactate
C. Glucose
D. α -Ketoglutarate
3920_Ch09_180-202 23/01/14 10:30 AM Page 201
Chapter 9 | Cerebrospinal Fluid
34. Before performing a Gram stain on CSF, the specimen
must be:
A. Filtered
B. Warmed to 37°C
C. Centrifuged
D. Mixed
201
36. The test of choice to detect neurosyphilis is the:
A. RPR
B. VDRL
C. FAB
D. FTA-ABS
35. All of the following statements are true about cryptococcal
meningitis except:
A. An India ink preparation is positive
B. A starburst pattern is seen on Gram stain
C. The WBC count is over 2000
D. A confirmatory immunology test is available
Case Studies and Clinical Situations
1. Three tubes of CSF containing evenly distributed visible
blood are drawn from a 75-year-old disoriented patient
and delivered to the laboratory. Initial test results are as
follows:
WBC count: 250 µ L
Protein: 150 mg/dL
Glucose: 70 mg/dL
Gram stain: No organisms
seen
Differential: Neutrophils, 68%; monocytes, 3%; lymphocytes, 28%; eosinophils, 1%
Many macrophages containing ingested RBCs
a. What is the most probable condition indicated by
these results? State two reasons for your answer.
b. Are the elevated WBC count and protein significant?
Explain your answer.
c. Are the percentages of the cells in the differential of
any significance? Explain your answer.
d. What two other structures besides RBCs might be
contained in the macrophages?
e. If the blood was unevenly distributed and nucleated
RBCs and capillary structures were seen instead of
macrophages, what would this indicate?
2. A patient with AIDS is hospitalized with symptoms of
high fever and rigidity of the neck. Routine laboratory
tests on the CSF show a WBC count of 100/µ L with a
predominance of lymphocytes and monocytes, glucose
of 55 mg/dL (plasma: 85 mg/dL), and a protein of
70 mg/dL. The Gram stain shows a questionable starburst
pattern.
a. What additional microscopic examination should be
performed?
b. If the test is positive, what is the patient’s diagnosis?
c. If the results of the test are questionable, what additional testing can be performed?
d. What could cause a false-positive reaction in this test?
e. If the tests named in a and c are negative, the glucose
level is 35 mg/dL, and a pellicle is observed in the
fluid, what additional testing should be performed?
f. If CSF and serum IEF was performed on this patient,
what unusual findings might be present?
3. A 35-year-old woman is admitted to the hospital with
symptoms of intermittent blurred vision, weakness, and
loss of sensation in her legs. A lumbar puncture is performed with the following results:
Appearance: Colorless, clear
WBC count: 35 cells/µ L (90% lymphocytes)
Glucose: 60 mg/dL (plasma: 100 mg/dL)
Protein: 60 mg/dL (serum: 8 g/dL)
Albumin: 40 mg/dL (serum: 6 g/dL)
IgG globulin: 20 mg/dL (serum: 2 g/dL)
a. Name and perform the calculation to determine the
integrity of the patient’s blood–brain barrier.
b. Does the patient have an intact barrier?
c. Name and perform the calculation used to determine
if IgG is being synthesized within the CNS.
d. What does this result indicate?
e. Considering the patient’s clinical symptoms and the
calculation results, what diagnosis is suggested?
f. If immunofixation electrophoresis is performed on
the patient’s serum and CSF, what findings would be
expected?
g. What substance in the CSF can be measured to monitor this patient?
3920_Ch09_180-202 23/01/14 10:30 AM Page 202
202
Part Three | Other Body Fluids
4. Mary Howard, age 5, is admitted to the pediatrics ward
with a temperature of 105%F, lethargy, and cervical rigidity. A lumbar spinal tap is performed, and three tubes of
cloudy CSF are delivered to the laboratory. Preliminary
test results are as follows:
Appearance: Cloudy
WBC count: 800 cells/µ L
Differential: 80% lymphocytes, 15% monocytes,
5% neutrophils
Protein: 65 mg/dL
Glucose: 70 mg/dL
Gram stain: No organisms seen
a. From these results, what preliminary diagnosis could
the physician consider?
b. Is the Gram stain result of particular significance?
Why or why not?
c. Are the lymphocytes significant? Why or why not?
d. Would a CSF lactate test be of any value for the diagnosis? Why or why not?
5. State possible technical errors that could result in the following discrepancies:
a. An unusual number of Gram stains reported as grampositive cocci fail to be confirmed by positive cultures.
b. A physician complains that CSF differentials are being
reported only as polynuclear and mononuclear cells.
c. Bacteria observed on the cytospin differential cannot
be confirmed by Gram stain or culture.
d. The majority of CSF specimens sent to the laboratory
from the neurology clinic have glucose readings less
than 50% of the corresponding blood glucose results
performed in the clinic.
3920_Ch10_203-216 23/01/14 10:31 AM Page 203
CHAPTER
10
Semen
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
10-1 State the structures involved in sperm production and
their function.
10-10 Describe the appearance of normal sperm, including
structures and their functions.
10-2 Describe the four components of semen with regard to
source and function.
10-11 Differentiate between routine and strict criteria for
evaluating sperm morphology.
10-3 Explain the procedures for collecting and handling
semen specimens.
10-12 Given an abnormal result in a routine semen analysis,
determine additional tests that might be performed.
10-4 Describe the normal appearance of semen and three
abnormalities in appearance.
10-13 Describe the two methods routinely used to detect
antisperm antibodies.
10-5 State two possible causes of low semen volume.
10-14 List two methods for identifying a questionable fluid
as semen.
10-6 Discuss the significance of semen liquefaction and
viscosity.
10-7 Calculate a sperm concentration and count when
provided with the number of sperm counted, the
dilution, the area of the counting chamber used, and
the ejaculate volume.
10-8 Define round cells, and explain their significance.
10-15 State the World Health Organization reference values
for routine and follow-up semen analysis.
10-16 Discuss the types and significance of sperm function
tests.
10-17 Describe methods of quality control appropriate for
semen analysis.
10-9 State the two parameters considered when evaluating
sperm motility.
KEY TERMS
Acrosomal cap
Prostate gland
Spermatozoa
Andrology
Semen
Vasectomy
Bulbourethral gland
Seminal vesicles
Viscosity
Epididymis
Seminiferous tubules
Liquefaction
Spermatids
3920_Ch10_203-216 23/01/14 10:31 AM Page 204
Part Three | Other Body Fluids
204
Advances in the field of andrology and assisted reproductive
technology (ART), and increased concern over fertility, particularly by couples choosing to have children later in life, have
resulted in increased emphasis on semen analysis. Patients
with abnormal results on the routine semen analysis performed
in the clinical laboratory often are referred to specialized andrology laboratories for further testing to determine the need
for in vitro fertilization (IVF). Clinical laboratory personnel
may also be employed in andrology laboratories and perform
both routine and specialized testing.
In addition to fertility testing, the clinical laboratory performs postvasectomy semen analysis and forensic analyses to
determine the presence of semen.
Physiology
Semen is composed of four fractions that are contributed
by the testes, epididymis, seminal vesicles, prostate gland,
and bulbourethral glands (Fig. 10–1). Each fraction differs in
its composition, and the mixing of all four fractions during
ejaculation is essential for the production of a normal semen
specimen (Table 10–1).
The testes are paired glands in the scrotum that contain
the seminiferous tubules for the secretion of sperm. The external location of the scrotum contributes to a lower scrotum
temperature that is optimal for sperm development. Germ cells
Table 10–1
Semen Composition
Spermatozoa
Seminal fluid
Prostate fluid
Bulbourethral glands
5%
60% to 70%
20% to 30%
5%
for the production of spermatozoa are located in the epithelial
cells of the seminiferous tubules. Specialized Sertoli cells provide support and nutrients for the germ cells as they undergo
mitosis and meiosis (spermatogenesis). When spermatogenesis
is complete, the immature sperm (nonmotile) enter the epididymis. In the epididymis, the sperm mature and develop flagella. The entire process takes approximately 90 days. The
sperm remain stored in the epididymis until ejaculation,
at which time they are propelled through the ductus deferens
(vas deferens) to the ejaculatory ducts.
The ejaculatory ducts receive both the sperm from the
ductus deferens and fluid from the seminal vesicles. The seminal vesicles produce most of the fluid present in semen (60%
to 70%), and this fluid is the transport medium for the sperm.
The fluid contains a high concentration of fructose and flavin.
Spermatozoa metabolize the fructose for the energy needed for
the flagella to propel them through the female reproductive
Urinary
bladder
Seminal
vesicle
Rectum
Vas
deferens
Ejaculatory
duct
Urethra
Prostate
gland
Penis
Glans
penis
Epididymis
Testis
Scrotum
Ureter
Vas
deferens
Prostate
gland
Anus
Bulbourethral
gland
Urinary
bladder
Seminal
vesicle
Bulbourethral
gland
Epididymis
Testis
Penis
Urethra
Figure 10–1 The male genitalia. Top, sagittal view; bottom,
anterior view.
3920_Ch10_203-216 23/01/14 10:31 AM Page 205
Chapter 10 | Semen
tract. In the absence of fructose, sperm do not display motility
in the semen analysis. Flavin is responsible for the gray appearance of semen. Various proteins secreted by the seminal
vesicles are involved in the coagulation of the ejaculate.
The muscular prostate gland, located just below the bladder, surrounds the upper urethra and aids in propelling the
sperm through the urethra by contractions during ejaculation.
Approximately 20% to 30% of the semen volume is acidic fluid
produced by the prostate gland. The milky acidic fluid contains
high concentrations of acid phosphatase, citric acid, zinc, and
proteolytic enzymes responsible for both the coagulation and
liquefaction of the semen following ejaculation.
The bulbourethral glands, located below the prostate, contribute about 5% of the fluid volume in the form of a thick,
alkaline mucus that helps to neutralize acidity from the
prostate secretions and the vagina. It is important for semen to
be alkaline to neutralize the vaginal acidity present as a result
of normal bacterial vaginal flora. Without this neutralization,
sperm motility would be diminished.
Specimen Collection
The variety in the composition of the semen fractions makes
proper collection of a complete specimen essential for accurate
evaluation of male fertility. Most of the sperm are contained in
the first portion of the ejaculate, making complete collection
essential for accurate testing of both fertility and postvasectomy
specimens. When a part of the first portion of the ejaculate is
missing, the sperm count will be decreased, the pH falsely
increased, and the specimen will not liquefy. When part of the
last portion of ejaculate is missing, the semen volume is
decreased, the sperm count is falsely increased, the pH is falsely
decreased, and the specimen will not clot. Patients should
receive detailed instructions for specimen collection.
Specimens are collected following a period of sexual abstinence of at least 2 days to not more than 7 days.1 Specimens
collected following prolonged abstinence tend to have higher
volumes and decreased motility.2 When performing fertility
testing, the World Health Organization (WHO) recommends
SUMMARY 10-1
Semen Production
Structure
Function
Seminiferous
tubules of testes
Epididymis
Ductus deferens
Seminal vesicles
Prostate gland
Spermatogenesis
Bulbourethral
glands
Sperm maturation
Propel sperm to ejaculatory ducts
Provide nutrients for sperm and fluid
Provide enzymes and proteins for
coagulation and liquefaction
Add alkaline mucus to neutralize
prostatic acid and vaginal acidity
205
that two or three samples be collected not less than 7 days or
more than 3 weeks apart, with two abnormal samples considered significant. The laboratory should provide the patient with
warm sterile glass or plastic containers. Whenever possible, the
specimen is collected in a room provided by the laboratory.
However, if this is not appropriate, the specimen should be
kept at room temperature and delivered to the laboratory
within 1 hour of collection. Laboratory personnel must record
the patient’s name and birth date, the period of sexual abstinence, the completeness of the sample, difficulties with collection, and the times of specimen collection and specimen
receipt. Specimens awaiting analysis should be kept at 37°C.
Specimens should be collected by masturbation. If this is not
possible, only nonlubricant-containing rubber or polyurethane
condoms should be used. Ordinary condoms are not acceptable because they contain spermicides.
TECHNICAL TIP Coitus interruptus is not a reliable
means of semen collection because the first portion of the
ejaculate, which contains the highest number of spermatozoa, may be lost and the low pH of the vaginal fluid may
affect sperm motility.1
Specimen Handling
All semen specimens are potential reservoirs for HIV and hepatitis viruses, and standard precautions must be observed at all
times during analysis. Specimens are discarded as biohazardous waste. Sterile materials and techniques must be used
when semen culture is to be performed or when the specimen
is to be processed for bioassay, intra-uterine insemination
(IUI), or in vitro fertilization (IVF).1
Semen Analysis
Semen analysis for fertility evaluation consists of both macroscopic and microscopic examination. Parameters reported
include appearance, volume, viscosity, pH, sperm concentration and count, motility, and morphology. Reference values are
shown in Table 10–2.
Appearance
Normal semen has a gray-white color, appears translucent, and
has a characteristic musty odor. When the sperm concentration
is very low, the specimen may appear almost clear.1 Increased
white turbidity indicates the presence of white blood cells
(WBCs) and infection within the reproductive tract. If required,
specimen culturing is performed prior to continuing with the
semen analysis. During microscopic examination, WBCs must
be differentiated from immature sperm (spermatids). The
leukocyte esterase reagent strip test may be useful to screen for
the presence of WBCs.3 Varying amounts of red coloration are
associated with the presence of red blood cells (RBCs) and
are abnormal. Yellow coloration may be caused by urine
3920_Ch10_203-216 23/01/14 10:31 AM Page 206
206
Part Three | Other Body Fluids
Table 10–2
Reference Values for Semen Analysis5
Volume
Viscosity
pH
Sperm
concentration
Sperm count
Motility
Quality
Morphology
Round cells
2 to 5 mL
Pours in droplets
7.2 to 8.0
>20 million/mL
>40 million/ejaculate
>50% within 1 h
>2.0 or a, b, c in Table 10–3
>14% normal forms (strict criteria)
>30% normal forms (routine criteria)
<1.0 million/mL
contamination, specimen collection following prolonged
abstinence, and medications. Urine is toxic to sperm, thereby
affecting evaluation of motility.
Liquefaction
A fresh semen specimen is clotted and should liquefy within
30 to 60 minutes after collection; therefore, recording the time
of collection is essential for evaluating semen liquefaction. Failure of liquefaction to occur within 60 minutes may be caused
by a deficiency in prostatic enzymes and should be reported.
Analysis of the specimen cannot begin until liquefaction has
occurred. If after 2 hours the specimen has not liquified, an
equal volume of physiologic Dulbecco’s phosphate-buffered
saline (Procedure 10-1) or proteolytic enzymes such as alphachymotrypsin or bromelain (Procedure 10-2) may be added to
induce liquefaction and allow the rest of the analysis to be performed. These treatments may affect biochemical tests, sperm
motility, and sperm morphology, so their use must be documented. The dilution of semen with bromelain must be accounted for when calculating sperm concentration.1 Jelly-like
granules (gelatinous bodies) may be present in liquefied semen
specimens and have no clinical significance. Mucus strands, if
present, may interfere with semen analysis.1
Volume
Normal semen volume ranges between 2 and 5 mL. It can be
measured by pouring the specimen into a clean graduated
cylinder calibrated in 0.1-mL increments. Increased volume
may be seen following periods of extended abstinence.
Decreased volume is more frequently associated with infertility
and may indicate improper functioning of one of the semenproducing organs, primarily the seminal vesicles. Incomplete
specimen collection must also be considered.
PROCEDURE 10-1
Semen Dilution With Physiologic Saline1
Prepare an equal volume of diluent and semen (1 part diluent and 1 part semen) using Dulbecco’s phosphate-buffered
saline. Repeated pipetting of the prepared dilution will
induce liquefaction.
Preparation of Dulbecco’s Phosphate-Buffered Saline1
1. Using a 1-L volumetric flask, add the following:
a. 750 ml of purified water
b. 0.20 g of potassium chloride (KCL)
c. 0.20 g of potassium dihydrogen phosphate (KH2PO4)
d. 0.10 g of magnesium chloride hexahydrate
(MgCl2.6H2O)
e. 8.0 g of sodium chloride (NaCl)
f. 2.16 g of disodium hydrogen phosphate heptahydrate (Na2HPO4.7H2O)
g. 1.00 g of D-glucose
2. In a 10-mL volumetric flask, dissolve 0.132 g of
calcium chloride dehydrate (CaCl2.2H2O) in 10 mL
of purified water.
3. To prevent precipitation, add calcium chloride dehydrated solution to the 1-L flask slowly, stirring continuously.
4. Adjust the pH to 7.4 with 1 mol/L sodium hydroxide
(NaOH).
5. Make up to 1000 mL with purified water.
PROCEDURE 10-2
Digestion With Bromelain1
1. Prepare 10 IU/mL bromelain in Dulbecco’s phosphatebuffered saline.
a. Into a 100-mL volumetric flask, add 1000 IU of
bromelain.
b. Add 60 mL Dulbecco’s phosphate-buffered saline.
c. Mix to dissolve. It takes about 15 to 20 minutes.
Bring volume to calibration mark using buffered
saline.
2. Dilute one part semen 1:2 with the 10 IU/mL
bromelain (1 part semen + 1 part bromelain solution).
3. Stir with a pipette tip.
4. Incubate at 37°C for 10 minutes.
5. Mix the sample well before analysis.
Viscosity
Specimen viscosity refers to the consistency of the fluid and
may be related to specimen liquefaction. Incompletely liquefied specimens are clumped and highly viscous. The normal
semen specimen should be easily drawn into a pipette and
TECHNICAL TIP Gently mixing the sample container during liquefaction can help produce a homogeneous sample.1
3920_Ch10_203-216 23/01/14 10:31 AM Page 207
Chapter 10 | Semen
form small discrete droplets that do not appear clumped or
stringy when falling by gravity from the pipette. Droplets that
form threads longer than 2 cm are considered highly viscous
and are recorded as abnormal. Ratings of 0 (watery) to 4
(gel-like) can be assigned to the viscosity report.4 Viscosity can
also be reported as low, normal, or high. Increased viscosity
and incomplete liquefaction impede testing for sperm motility,
sperm concentration, antisperm antibody detection, and measurement of biochemical markers.1
W
W
R
Sperm Concentration and Sperm Count
Even though fertilization is accomplished by one spermatozoon,
the actual number of sperm present in a semen specimen is a
valid measurement of fertility. Various factors can affect sperm
concentration, such as the days of sexual abstinence before the
collection, infection, or stress; therefore, more than one semen
specimen should be evaluated for infertility studies. Reference
values for sperm concentration are commonly listed as greater
than 20 to 250 million sperm per milliliter; concentrations between 10 and 20 million per milliliter are considered borderline. The total sperm count for the ejaculate can be calculated
by multiplying the sperm concentration by the specimen volume. Total sperm counts greater than 40 million per ejaculate
are considered normal (20 million per milliliter × 2 mL).
In the clinical laboratory, sperm concentration is usually
performed using the Neubauer counting chamber. The sperm
are counted in the same manner as cells in the cerebrospinal
fluid cell count, that is, by diluting the specimen and counting
the cells in the Neubauer chamber. The amount of the dilution
and the number of squares counted vary among laboratories.
The most commonly used dilution is 1:20 prepared using
a mechanical (positive-displacement) pipette.5 Dilution of the
semen is essential because it immobilizes the sperm before
counting. The traditional diluting fluid contains sodium bicarbonate and formalin, which immobilize and preserve the cells;
however, good results can also be achieved using saline and
distilled water.
Using the Neubauer hemocytometer, sperm are usually
counted in the four corner and center squares of the large center square, similar to a manual RBC count (Fig. 10–2). Both
sides of the hemocytometer are loaded and allowed to settle
for 3 to 5 minutes; then they are counted, and the counts
should agree within 10%. An average of the two counts is used
R
R
pH
The pH of semen indicates the balance between the pH values
from the acidic prostatic secretion and the alkaline seminal
vesicles secretion. The pH should be measured within 1 hour
of ejaculation due to the loss of CO2 that occurs.1 The normal pH
of semen is alkaline with a range of 7.2 to 8.0. Increased pH
indicates infection within the reproductive tract. A decreased
pH may be associated with increased prostatic fluid, ejaculatory duct obstruction, or poorly developed seminal vesicles.1
Semen for pH testing can be applied to the pH pad of a urinalysis reagent strip and the color compared with the manufacturer’s chart. Dedicated pH testing paper also can be used.
207
R
W
R
W
Figure 10–2 Areas of the Neubauer counting chamber used for red
and white blood cell counts. W, typical WBC counting area; R, typical
RBC counting area.
in the calculation. If the counts do not agree, both the dilution
and the counts are repeated. Counts are performed using either
phase or bright-field microscopy. The addition of stain, such
as crystal violet, to the diluting fluid aids in visualization when
using bright-field microscopy.
Only fully developed sperm should be counted. Immature
sperm and WBCs, often referred to as “round” cells, must not
be included. However, their presence can be significant, and
they may need to be identified and counted separately. Stain
included in the diluting fluid aids in differentiating between
immature sperm cells (spermatids) and leukocytes, and they
can be counted in the same manner as mature sperm. A count
greater than 1 million leukocytes per milliliter is associated
with inflammation or infection of the reproductive organs that
can lead to infertility.
The presence of more than 1 million spermatids per
milliliter indicates disruption of spermatogenesis. This may be
caused by viral infections, exposure to toxic chemicals, and
genetic disorders.
Calculating Sperm Concentration and Sperm Count
Calculation of sperm concentration depends on the dilution
used and the size and number of squares counted. When using
the 1:20 dilution and counting the five squares (RBCs) in the
large center square as described previously, the number of
sperm can be multiplied by 1,000,000 (add 6 zeros) to equal
the sperm concentration per milliliter. Notice that, unlike
blood cell counts, the sperm concentration is reported in millions per milliliter rather than microliters. Sperm concentration
can also be calculated using the basic formula for cell counts
3920_Ch10_203-216 23/01/14 10:31 AM Page 208
208
Part Three | Other Body Fluids
covered in Chapter 9. Because this formula provides the number of cells per microliter, the figure must then be multiplied
by 1000 to calculate the number of sperm per milliliter. The
total sperm count is calculated by multiplying the number of
sperm per milliliter by the specimen volume.
EXAMPLES
1. Using a 1:20 dilution, an average of 60 sperm are
counted in the five RBC counting squares on both sides
of the hemocytometer. Calculate the sperm concentration per milliliter and the total sperm count in a specimen with a volume of 4 mL.
60 sperm counted × 1,000,000 = 60,000,000 sperm/mL
60,000,000 sperm/mL × 4 mL = 240,000,000 sperm/
ejaculate
2. In a 1:20 dilution, 600 sperm are counted in two WBC
counting squares. Calculate the sperm concentration per
milliliter and the total sperm count in a specimen with a
volume of 2 µ L.
600 sperm counted × 20 (dilution)
60,000 sperm/µL
=
2 sq mm × squares counted) ×
(volume counted)
0.1 mm (depth)
60,000 sperm/µL × 1000 = 60,000,000 sperm/mL
60,000,000/mL × 2 mL = 120,000,000 sperm/ejaculate
Several methods have been developed using specially designed and disposable counting chambers that do not require
specimen dilution. Comparison of these methods and the
standard Neubauer counting chamber method showed poor
correlation with the Neubauer method and also among themselves. The WHO states that the “validity of these alternative
counting chambers must be established by checking chamber
dimensions, comparing results with the improved Neubauer
hemocytometer method, and obtaining satisfactory performance as shown by an external quality control program.”1
Sperm Motility
The presence of sperm capable of forward, progressive movement is critical for fertility, because once presented to the
cervix, the sperm must propel themselves through the cervical
mucosa to the uterus, fallopian tubes, and ovum. Traditionally,
clinical laboratory reporting of sperm motility has been a subjective evaluation performed by examining an undiluted specimen and determining the percentage of motile sperm and the
quality of the motility.
Sperm motility should be assessed using a well-mixed,
liquefied semen specimen within 1 hour of specimen collection. The practice of examining sperm motility at timed intervals over an extended period has been shown to serve no
useful purpose.6 To provide continuity in reporting, laboratories should place a consistent amount of semen on a slide
under the same size cover slip, such as 10 µL under a 22 ×
22 mm cover slip using a calibrated positive-displacement
pipette, and allow it to settle for 1 minute. This procedure
should be done in duplicate for accuracy. The percentage of
sperm showing actual forward movement can then be estimated after evaluating approximately 20 high-power fields.
An alternate procedure is to examine 200 sperm per slide
and count the percentages of the different motile categories
using a manual cell counter.1 Motility is evaluated by both
speed and direction. Grading can be done using a scale of 0
to 4, with 4 indicating rapid, straight-line movement and 0
indicating no movement (Table 10–3). A minimum motility
of 50% with a rating of 2.0 after 1 hour is considered normal.2
The WHO uses a rating scale of a, b, c, d (see Table 10–3).
Interpretation states that within 1 hour, 50% or more of the
sperm should be motile in categories a, b, and c, or 25% or
more should show progressive motility (a and b).5
The WHO Laboratory Manual for the Examination and
Processing of Human Semen (2010)1 currently recommends a
simpler system for grading motility that does not include
speed because of the difficulty in standardized reporting.
Motility is graded as progressive motility (PM), nonprogressive
motility (NP), and immotility (IM). Motility must be specified
as total motility (PM and NP) or progressive motility (PM).1
(See Table 10–4.)
The presence of a high percentage of immobile sperm and
clumps of sperm requires further evaluation to determine
sperm vitality or the presence of sperm agglutinins.
In recent years, instrumentation capable of performing
computer-assisted semen analysis (CASA) has been developed.
Table 10–3
Grade
Sperm Motility Grading
WHO Criteria
4.0
3.0
a
b
2.0
b
1.0
0
c
d
Table 10–4
Sperm Motility Action
Rapid, straight-line motility
Slower speed, some lateral
movement
Slow forward progression,
noticeable lateral movement
No forward progression
No movement
Alternative Sperm Motility Grading
Criteria1
Progressive
motility (PM)
Nonprogressive
motility (NP)
Immotility (IM)
Sperm moving linearly or in a
large circle
Sperm moving with an absence
of progression
No movement
3920_Ch10_203-216 23/01/14 10:31 AM Page 209
Chapter 10 | Semen
CASA provides objective determination of both sperm velocity
and trajectory (direction of motion). Sperm concentration and
morphology are also included in the analysis. Currently, CASA
instrumentation is found primarily in laboratories that specialize in andrology and perform a high volume of semen analysis.
Sperm Morphology
Just as the presence of a normal number of sperm that are nonmotile produces infertility, the presence of sperm that are morphologically incapable of fertilization also results in infertility.
Sperm morphology is evaluated with respect to the structure
of the head, neckpiece, midpiece, and tail. Abnormalities in head
morphology are associated with poor ovum penetration, whereas
neckpiece, midpiece, and tail abnormalities affect motility.
The normal sperm has an oval-shaped head approximately
5 µm long and 3 µm wide and a long, flagellar tail approximately 45 µm long (Fig. 10–3). Critical to ovum penetration
is the enzyme-containing acrosomal cap located at the tip of
the head. The acrosomal cap should encompass approximately
half of the head and cover approximately two thirds of the
sperm nucleus.5 The neckpiece attaches the head to the tail
and the midpiece. The midpiece is approximately 7.0 µm long
and is the thickest part of the tail because it is surrounded by
a mitochondrial sheath that produces the energy required by
the tail for motility.
209
Sperm morphology is evaluated from a thinly smeared,
stained slide under oil immersion. Smears are made by placing
approximately 10 µL of semen near the frosted end of a clean
microscope slide. Place a second slide with a clean, smooth
edge in front of the semen drop at a 45° angle and draw the
slide back to the edge of the drop of semen, allowing the semen
to spread across the end. When the semen is evenly distributed
across the spreader slide, lightly pull the spreader slide forward
with a continuous movement across the first slide to produce
a smear. Staining can be performed using Wright’s, Giemsa,
Shorr, or Papanicolaou stain and is a matter of laboratory preference. Air-dried slides are stable for 24 hours. At least 200
sperm should be evaluated and the percentage of abnormal
sperm reported. Routinely identified abnormalities in head
structure include double heads, giant and amorphous heads,
pinheads, tapered heads, and constricted heads (Figs. 10–4
and 10–5). Abnormal sperm tails are frequently doubled,
coiled, or bent (Figs. 10–6 and 10–7). An abnormally long
neckpiece may cause the sperm head to bend backward and
interfere with motility (Fig. 10–8).
TECHNICAL TIP Sperm motility can be evaluated at
room temperature or 37°C. When assessing motility at
37°C, the sample should be incubated at this temperature
and the preparation made with prewarmed slides and
cover slips.1
Acrosome
Head
Cell membrane
Nucleus
Figure 10–4 Spermatozoon with double head, hematoxylin-eosin
(×1000).
Midpiece
Mitochondria
Tail
(flagellum)
Figure 10–3 Normal spermatozoon structure.
Figure 10–5 Spermatozoon with amorphous head, hematoxylin-eosin
(×1000).
3920_Ch10_203-216 23/01/14 10:31 AM Page 210
210
Part Three | Other Body Fluids
Calculating Round Cells
Differentiation and enumeration of round cells (immature
sperm and leukocytes) can also be made during the morphology examination (Fig. 10–9). Peroxidase-positive granulocytes
are the predominant form of leukocyte in semen and can be
further differentiated from spermatogenic cells and lymphocytes using a peroxidase stain. By counting the number of
spermatids or leukocytes seen in conjunction with 100 mature
sperm, the amount per milliliter can be calculated using the
following formula, where N is the number of spermatids or
neutrophils counted per 100 mature sperm, and S is the
sperm concentration in millions per milliliter:
Figure 10–6 Spermatozoon with double tail, hematoxylin-eosin
(×1000).
Additional parameters in evaluating sperm morphology include measuring head, neck, and tail size; measuring acrosome
size; and evaluating for the presence of vacuoles. Inclusion of
these parameters is referred to as Kruger’s strict criteria.7 Strict
criteria evaluation requires the use of a stage micrometer or morphometry.8 At present, evaluation of sperm morphology using
strict criteria is not routinely performed in the clinical laboratory
but is recommended by the WHO.5 Strict criteria evaluation is
an integral part of assisted reproduction evaluations.
Normal values for sperm morphology depend on the evaluation method used and vary from greater than 30% normal
forms when using routine criteria to greater than 14% normal
forms when using strict criteria.5
Normal
Double
head
Tapered
head
Constricted
head
Giant
head
Double
tail
Amorphous
head
Coiled
tail
C =
N × S
100
This method can be used when counting cannot be performed during the hemocytometer count and to verify counts
performed by hemocytometer.
Greater than 1 million WBCs per milliliter per ejaculate
indicates an inflammatory condition associated with infection
and poor sperm quality and may impair sperm motility and
DNA integrity.1
Additional Testing
Should abnormalities be discovered in any of these routine
parameters, additional tests may be requested (Table 10–5).
The most common are tests for sperm vitality, seminal fluid
fructose level, sperm agglutinins, and microbial infection.
Pinhead
Spermatid
Figure 10–7 Common abnormalities of
sperm heads and tails.
3920_Ch10_203-216 23/01/14 10:31 AM Page 211
Chapter 10 | Semen
Table 10–5
211
Additional Testing for Abnormal Semen
Analysis
Abnormal
Result
Possible
Abnormality
Decreased
motility with
normal count
Decreased count
Vitality
Eosin-nigrosin
stain
Fructose level
Decreased motility
with clumping
Lack of seminal
vesicle support medium
Male antisperm
antibodies
Normal analysis
with continued
infertility
Female
antisperm
antibodies
Figure 10–8 Spermatozoon with bent neck and spermatid,
hematoxylin-eosin (×1000).
Test
Mixed
agglutination
reaction and
immunobead
tests
Sperm agglutination with
male serum
Sperm agglutination with
female serum
Figure 10–9 Immature spermatozoa, hematoxylin-eosin (×1000).
Sperm Vitality
Decreased sperm vitality may be suspected when a specimen
has a normal sperm concentration with markedly decreased
motility. Sperm vitality should be assessed within 1 hour of
ejaculation. Vitality is evaluated by mixing the specimen
with an eosin-nigrosin stain, preparing a smear, and counting the number of dead cells in 100 sperm using a brightfield or phase-contrast microscope. Living cells are not
infiltrated by the dye and remain bluish white, whereas dead
cells stain red against the purple background (Fig. 10–10).
Normal vitality requires 50% or more living cells and should
correspond to the previously evaluated motility. The presence of a large proportion of vital but immobile cells may indicate a defective flagellum, whereas a high number of
immotile and nonviable cells may indicate epididymal
pathology.1
Seminal Fluid Fructose
Low sperm concentration may be caused by lack of the
support medium produced in the seminal vesicles, which
can be indicated by a low to absent fructose level in the
Figure 10–10 Nonviable spermatozoa demonstrated by the eosinnigrosin stain (×1000).
semen. Low fructose levels are caused by abnormalities
of the seminal vesicles, bilateral congenital absence of the
vas deferens, obstruction of the ejaculatory duct, partial retrograde ejaculation, and androgen deficiency. 1 Specimens
can be screened for the presence of fructose using the resorcinol test that produces an orange color when fructose is
present (Procedure 10-3).
A normal quantitative level of fructose is equal to or
greater than 13 µmol per ejaculate. This can be determined
using spectrophotometric methods. Specimens for fructose
levels should be tested within 2 hours of collection or frozen
to prevent fructolysis.
3920_Ch10_203-216 23/01/14 10:32 AM Page 212
212
Part Three | Other Body Fluids
PROCEDURE 10-3
Seminal Fructose Screening Test6
1. Prepare reagent (50 mg resorcinol in 33 mL concentrated HCl diluted to 100 mL with water).
2. Mix 1 mL of semen with 9 mL of reagent.
3. Boil.
4. Observe for orange-red color.
Antisperm Antibodies
Antisperm antibodies can be present in both men and
women. They may be detected in semen, cervical mucosa, or
serum, and are considered a possible cause of infertility. It is
not unusual for both partners to demonstrate antibodies,
although male antisperm antibodies are more frequently
encountered.
Under normal conditions, the blood–testes barrier separates sperm from the male immune system. When this barrier
is disrupted, as can occur following surgery, vasectomy reversal (vasovasostomy), trauma, and infection, the antigens on
the sperm produce an immune response that damages the
sperm. The damaged sperm may cause the production of
antibodies in the female partner.9
The presence of antibodies in a male subject can be suspected when clumps of sperm are observed during a routine
semen analysis. Sperm-agglutinating antibodies cause sperm
to stick to each other in a head-to-head, head-to-tail, or tailto-tail pattern.1 The agglutination is graded as “few,” “moderate,” or “many” on microscopic examination.
The presence of antisperm antibodies in a female subject
results in a normal semen analysis accompanied by continued
infertility. The presence of antisperm antibodies in women may
be demonstrated by mixing the semen with the female cervical
mucosa or serum and observing for agglutination. A variety
of immunoassay kits are available for both semen and serum
testing.
Two frequently used tests to detect the presence of antibody-coated sperm are the mixed agglutination reaction
(MAR) test and the immunobead test. The MAR test is a
screening procedure used primarily to detect the presence
of immunoglobulin G (IgG) antibodies. The semen sample
containing motile sperm is incubated with IgG antihuman
globulin (AHG) and a suspension of latex particles or treated
RBCs coated with IgG. The bivalent AHG binds simultaneously to both the antibody on the sperm and the antibody
on the latex particles or RBCs, forming microscopically visible clumps of sperm and particles or cells. A finding of less
than 10% of the motile sperm attached to the particles is
considered normal.
The immunobead test is a more specific procedure in that
it can be used to detect the presence of IgG, IgM, and IgA antibodies and demonstrates what area of the sperm (head,
neckpiece, midpiece, or tail) the autoantibodies are affecting.
Head-directed antibodies can interfere with penetration into
the cervical mucosa or ovum, whereas tail-directed antibodies
affect movement through the cervical mucosa.10 In the immunobead test, sperm are mixed with polyacrylamide beads
known to be coated with either anti-IgG, anti-IgM, or antiIgA. Microscopic examination of the sperm shows the beads
attached to sperm at particular areas. Depending on the type
of beads used, the test could be reported as “IgM tail antibodies,” “IgG head antibodies,” and so forth. The presence of
beads on less than 50% of the sperm is considered normal as
defined by the WHO.1
Microbial and Chemical Testing
The presence of more than 1 million leukocytes per millimeter
indicates infection within the reproductive system, frequently
the prostate. Routine aerobic and anaerobic cultures and tests
for Chlamydia trachomatis, Mycoplasma hominis, and Ureaplasma
urealyticum are most frequently performed.
Additional chemical testing performed on semen may include determining the levels of neutral α -glucosidase, free
L-carnitine, glycerophosphocholine, zinc, citric acid, glutamyl
transpeptidase, and prostatic acid phosphatase. Just as decreased fructose levels are associated with a lack of seminal
fluid, decreased neutral α -glucosidase, glycerophosphocholine, and L-carnitine suggest a disorder of the epididymis.
Decreased zinc, citric acid, glutamyl transpeptidase, and acid
phosphatase indicate a lack of prostatic fluid (Table 10–6).
Spectrophotometric methods are used to quantitate citric acid
and zinc.
On certain occasions, the laboratory may be called on
to determine whether semen is actually present in a specimen. A primary example is in cases of alleged rape. Microscopically examining the specimen for the presence of sperm
may be possible, with the best results being obtained by
enhancing the specimen with xylene and examining under
phase microscopy.11 Motile sperm can be detected for up to
24 hours after intercourse, whereas nonmotile sperm can
persist for 3 days. As the sperm die off, only the heads
remain and may be present for 7 days after intercourse. Seminal fluid contains a high concentration of prostatic acid
phosphatase, so detecting this enzyme can aid in determining the presence of semen in a specimen. A more specific
method is the detection of seminal glycoprotein p30
(prostatic specific antigen [PSA]), which is present even in
the absence of sperm. 12 Further information can often be
obtained by performing ABO blood grouping and DNA
analysis on the specimen.
Table 10–6
Reference Semen Chemical Values1
Neutral α -glucosidase
Zinc
Citric acid
Acid phosphatase
≥ 20 mU/ejaculate
≥ 2.4 µmol/ejaculate
≥ 52 µmol/ejaculate
≥ 200 Units/ejaculate
3920_Ch10_203-216 23/01/14 10:32 AM Page 213
Chapter 10 | Semen
Postvasectomy Semen Analysis
Postvasectomy semen analysis is a much less involved procedure when compared with infertility analysis because the only
concern is the presence or absence of spermatozoa. The length
of time required for complete sterilization can vary greatly
among patients and depends on both time and number of
ejaculations. Therefore, finding viable sperm in a postvasectomy patient is not uncommon, and care should be taken not
to overlook even a single sperm. Specimens are routinely
tested at monthly intervals, beginning at 2 months postvasectomy and continuing until two consecutive monthly specimens show no spermatozoa.
Recommended testing includes examining a wet preparation using phase microscopy for the presence of motile and
nonmotile sperm. A negative wet preparation is followed by
specimen centrifugation for 10 minutes and examination of the
sediment.6
the motility and morphology analyses. The analysis is rated
as a high complexity test under the Clinical Laboratory Improvement Amendments, and testing personnel standards
must be observed.
Increased interest in fertility testing has promoted the development of quality control materials and in-depth training
programs. The standardized procedures developed by the
WHO have provided a basis for laboratory testing and reporting. The use of CASA has aided in reducing the subjectivity of
the analysis. However, even computerized analysis has been
shown to vary among operators.15
Laboratories can now participate in proficiency testing
programs offered by the College of American Pathologists and
the American Association of Bioanalysts that include sperm
concentration, vitality, and morphology. Commercial qualitycontrol materials and training aids are available and should be
incorporated into laboratory protocols.
Sperm Function Tests
Advances in assisted reproduction and IVF have resulted in a
need for more sophisticated semen analysis to assess not only
the characteristics of sperm but also the functional ability. The
tests are most commonly performed in specialized andrology
laboratories and include the hamster egg penetration assay, cervical mucus penetration test, hypo-osmotic swelling test, and
the in vitro acrosome reaction (Table 10–7).13
Semen Analysis Quality Control
Traditionally, routine semen analysis has been subject to very
little quality control,14 a situation that has resulted from a
lack of appropriate control materials and the subjectivity of
TECHNICAL TIP A single “motile” sperm on a wet preparation is an indication of an unsuccessful vasectomy.
Table 10–7
Sperm Function Tests
Test
Description
Hamster egg
penetration
Sperm are incubated with speciesnonspecific hamster eggs and penetration is observed microscopically
Observation of sperm’s ability to
penetrate partner’s midcycle
cervical mucus
Sperm exposed to low-sodium concentrations are evaluated for membrane integrity and sperm viability
Evaluation of the acrosome to
produce enzymes essential for
ovum penetration
Cervical mucus
penetration
Hypo-osmotic
swelling
In vitro acrosome
reaction
213
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. WHO Laboratory Manual for the Examination and Processing
of Human Semen. World Health Organization. WHO Press,
Geneva, Switzerland, 2010.
2. Sarhar, S, and Henry, JB: Andrology laboratory and fertility
assessment. In Henry, JB (ed): Clinical Diagnosis and Management by Laboratory Methods. WB Saunders, Philadelphia, 1996.
3. Lopez, A, et al: Suitability of solid-phase chemistry for quantification of leukocytes in cerebrospinal, seminal and peritoneal
fluid. Clin Chem 33(8):1475–1476, 1987.
4. Overstreet, JW, and Katz, DF: Semen analysis. Urol Clin North
Am 14(3):441–449, 1987.
5. World Health Organization: WHO Laboratory Manual for the
Examination of Human Semen and Sperm-Cervical Interaction.
Cambridge University Press, London, 1999.
6. Sampson, JH, and Alexander, NJ: Semen analysis: A laboratory
approach. Lab Med 13(4):218–223, 1982.
7. Kruger, T, et al: Predictive value of sperm morphology in IVF.
Fertil Steril 112–117, 1988.
8. Harr, R: Characterization of spermatozoa by planar morphometry.
Clin Lab Sci 10(4):190–196, 1997.
9. Cearlock, DM: Autoimmune antispermatozoa antibodies in
men: Clinical detection and role in infertility. Clin Lab Sci
2(3):165–168, 1989.
10. Marshburn, PB, and Kutteh, WH: The role of antisperm
antibodies in infertility. Fertil Steril 61:799–811, 1994.
11. Fraysier, HD: A rapid screening technique for the detection of
spermatozoa. J Forensic Sci 32(2):527–528, 1987.
12. Graves, HC, Sensabaugh, CF, and Blake, ET: Postcoital
detection of a male-specific semen protein, application to the
investigation of rape. N Engl J Med 312(6):338–343, 1985.
13. Yablonsky, T: Male fertility testing. Lab Med 27(6):378–383,
1996.
14. Baker, DJ, et al: Semen evaluations in the clinical laboratory.
Lab Med 25(8):509–514, 1994.
15. Krause, W, and Viethen, G: Quality assessment of computer-assisted semen analysis (CASA) in the andrology
laboratory. Andrologia 31(3):125–129, 1999.
3920_Ch10_203-216 23/01/14 10:32 AM Page 214
214
Part Three | Other Body Fluids
Study Questions
1. Maturation of spermatozoa takes place in the:
A. Sertoli cells
B. Seminiferous tubules
C. Epididymis
D. Seminal vesicles
2. Enzymes for the coagulation and liquefaction of semen are
produced by the:
A. Seminal vesicles
B. Bulbourethral glands
C. Ductus deferens
D. Prostate gland
3. The major component of seminal fluid is:
A. Glucose
B. Fructose
C. Acid phosphatase
D. Citric acid
4. If the first portion of a semen specimen is not collected, the
semen analysis will have which of the following?
A. Decreased pH
B. Increased viscosity
C. Decreased sperm count
D. Decreased sperm motility
5. Failure of laboratory personnel to document the time a
semen sample is collected primarily affects the interpretation of semen:
A. Appearance
B. Volume
C. pH
D. Viscosity
6. Liquefaction of a semen specimen should take place within:
A. 1 hour
B. 2 hours
C. 3 hours
D. 4 hours
7. A semen specimen delivered to the laboratory in a condom
has a normal sperm count and markedly decreased sperm
motility. This indicates:
A. Decreased fructose
B. Antispermicide in the condom
C. Increased semen viscosity
D. Increased semen alkalinity
8. An increased semen pH may be caused by:
A. Prostatic infection
B. Decreased prostatic secretions
C. Decreased bulbourethral gland secretions
D. All of the above
9. Proteolytic enzymes may be added to semen specimens to:
A. Increase the viscosity
B. Dilute the specimen
C. Decrease the viscosity
D. Neutralize the specimen
10. The normal sperm concentration is:
A. Less than 20 million/µ L
B. More than 20 million/mL
C. Less than 20 million/mL
D. More than 20 million/µ L
11. Given the following information, calculate the sperm concentration: dilution, 1:20; sperm counted in five RBC
squares on each side of the hemocytometer, 80 and 86;
volume, 3 mL.
A. 80 million/mL
B. 83 million/mL
C. 86 million/mL
D. 169 million/µ L
12. Using the above information, calculate the sperm concentration when 80 sperm are counted in 1 WBC square and
86 sperm are counted in another WBC square.
A. 83 million/mL
B. 166 million per ejaculate
C. 16.6 million/mL
D. 50 million per ejaculate
13. The primary reason to dilute a semen specimen before
performing a sperm concentration is to:
A. Immobilize the sperm
B. Facilitate the chamber count
C. Decrease the viscosity
D. Stain the sperm
3920_Ch10_203-216 23/01/14 10:32 AM Page 215
Chapter 10 | Semen
14. When performing a sperm concentration, 60 sperm are
counted in the RBC squares on one side of the hemocytometer and 90 sperm are counted in the RBC squares on
the other side. The specimen is diluted 1:20. The:
A. Specimen should be rediluted and counted
B. Sperm count is 75 million/mL
C. Sperm count is greater than 5 million/mL
D. Sperm concentration is abnormal
15. Sperm motility evaluations are performed:
A. Immediately after the specimen is collected
B. Within 1 hour of collection
C. After 3 hours of incubation
D. At 6-hour intervals for 1 day
16. The percentage of sperm showing average motility that is
considered normal is:
A. 25%
B. 50%
C. 60%
D. 75%
17. The purpose of the acrosomal cap is to:
A. Penetrate the ovum
B. Protect the the nucleus
C. Create energy for tail movement
D. Protect the neckpiece
18. The sperm part containing a mitochondrial sheath is the:
A. Head
B. Neckpiece
C. Midpiece
D. Tail
19. All of the following are associated with sperm motility
except the:
A. Head
B. Neckpiece
C. Midpiece
D. Tail
20. The morphologic shape of a normal sperm head is:
A. Round
B. Tapered
C. Oval
D. Amorphous
21. Normal sperm morphology when using the WHO criteria is:
A. >30% normal forms
B. <30% normal forms
C. >15% abnormal forms
D. <15% normal forms
215
22. Additional parameters measured by Kruger’s strict morphology include all of the following except:
A. Vitality
B. Presence of vacuoles
C. Acrosome size
D. Tail length
23. Round cells that are of concern and may be included in
sperm counts and morphology analysis are:
A. Leukocytes
B. Spermatids
C. RBCs
D. Both A and B
24. If 5 round cells per 100 sperm are counted in a sperm morphology smear and the sperm concentration is 30 million,
the concentration of round cells is:
A. 150,000
B. 1.5 million
C. 300,000
D. 15 million
25. Following an abnormal sperm motility test with a normal
sperm count, what additional test might be ordered?
A. Fructose level
B. Zinc level
C. MAR test
D. Eosin-nigrosin stain
26. Follow-up testing for a low sperm concentration would
include testing for:
A. Antisperm antibodies
B. Seminal fluid fructose
C. Sperm vitality
D. Prostatic acid phosphatase
27. The immunobead test for antisperm antibodies:
A. Detects the presence of male antibodies
B. Determines the presence of IgG, IgM, and IgA
antibodies
C. Determines the location of antisperm antibodies
D. All of the above
28. Measurement of α -glucosidase is performed to detect a
disorder of the:
A. Seminiferous tubules
B. Epididymis
C. Prostate gland
D. Bulbourethral glands
3920_Ch10_203-216 23/01/14 10:32 AM Page 216
216
Part Three | Other Body Fluids
29. A specimen delivered to the laboratory with a request
for prostatic acid phosphatase and glycoprotein p30 was
collected to determine:
A. Prostatic infection
B. Presence of antisperm antibodies
C. A possible rape
D. Successful vasectomy
31. Standardization of procedures and reference values for
semen analysis is primarily provided by the:
A. Manufacturers of instrumentation
B. WHO
C. Manufacturers of control samples
D. Clinical Laboratory Improvement Amendments
30. Following a negative postvasectomy wet preparation, the
specimen should be:
A. Centrifuged and reexamined
B. Stained and reexamined
C. Reported as no sperm seen
D. Both A and B
Case Studies and Clinical Situations
1. A repeat semen analysis for fertility testing is reported as
follows:
VOLUME: 3.5 mL
SPERM COUNT: 6 million/mL
VISCOSITY: Normal
SPERM MOTILITY: 30%—
grade 1.0
pH: 7.5
MORPHOLOGY: <30% normal
forms—30 spermatids/100 sperm
The results correspond with the first analysis.
a. List three abnormal parameters.
b. What is the sperm concentration? Is this normal?
c. What is the spermatid count? Is this normal?
d. Could the sperm concentration and the spermatid
count be related to the infertility? Explain your answer.
2. A semen analysis on a vasovasostomy patient has a normal sperm concentration; however, motility is decreased,
and clumping is observed on the wet preparation.
a. Explain the possible connection between these observations and the patient’s recent surgery.
b. What tests could be performed to further evaluate the
patient’s infertility?
c. Briefly explain the different interpretations offered by
these two tests.
d. State three ways in which a positive result on these
tests could be affecting male fertility.
3. A yellow-colored semen specimen is received in the laboratory. The analysis is normal except for decreased sperm
motility. Explain the possible connection between the two
abnormal findings.
4. Abnormal results of a semen analysis are volume = 1.0 mL
and sperm concentration = 1 million/mL. State a nonpathologic cause of these abnormal results.
5. A semen specimen with normal initial appearance fails to
liquefy after 60 minutes.
a. Would a specimen pH of 9.0 be consistent with this
observation? Why or why not?
b. State three chemical tests that would be of value in
this analysis.
c. How does this abnormality affect fertility?
6. A specimen is delivered to the laboratory with a request to
determine if semen is present.
a. What two chemical tests could be performed on the
specimen?
b. What additional examination could be performed on
the specimen?
3920_Ch11_217-228 23/01/14 10:33 AM Page 217
CHAPTER
11
Synovial Fluid
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
11-1 Describe the formation and function of synovial fluid.
11-7 List and describe six crystals found in synovial fluid.
11-2 Relate laboratory test results to the four common
classifications of joint disorders.
11-8 Explain the differentiation of monosodium urate and
calcium pyrophosphate crystals using polarized and
compensated polarized light.
11-3 State the five diagnostic tests most routinely
performed on synovial fluid.
11-4 Determine the appropriate collection tubes for
requested laboratory tests on synovial fluid.
11-5 Describe the appearance of synovial fluid in normal
and abnormal states.
11-6 Discuss the normal and abnormal cellular
composition of synovial fluid.
11-9 State the clinical significance of glucose and lactate
tests on synovial fluid.
11-10 List four genera of bacteria most frequently found in
synovial fluid.
11-11 Describe the relationship of serologic serum testing to
joint disorders.
KEY TERMS
Arthritis
Hyaluronic acid
Synovial fluid
Arthrocentesis
Pseudogout
Synoviocytes
Gout
3920_Ch11_217-228 23/01/14 10:34 AM Page 218
218
Part Three | Other Body Fluids
Physiology
Table 11–1
Synovial fluid, often referred to as “joint fluid,” is a viscous
liquid found in the cavities of the movable joints (diarthroses)
or synovial joints. As shown in Figure 11–1, the bones in the
synovial joints are lined with smooth articular cartilage and
separated by a cavity containing the synovial fluid. The joint
is enclosed in a fibrous joint capsule lined by the synovial
membrane. The synovial membrane contains specialized cells
called synoviocytes. The smooth articular cartilage and synovial fluid together reduce friction between the bones during
joint movement. In addition to providing lubrication in the
joints, synovial fluid provides nutrients to the articular cartilage
and lessens the shock of joint compression that occurs during
activities such as walking and jogging.
Synovial fluid is formed as an ultrafiltrate of plasma across
the synovial membrane. The filtration is nonselective except
for the exclusion of high-molecular-weight proteins. Therefore,
most of the chemical constituents, although seldom of clinical
significance, have concentrations similar to plasma values.
They do, however, provide nutrients for the vascular-deficient
cartilage. The synoviocytes secrete a mucopolysaccharide containing hyaluronic acid and a small amount of protein (approximately one fourth of the plasma concentration) into the
fluid. The large hyaluronate molecules contribute the noticeable viscosity to the synovial fluid. Damage to the articular
membranes produces pain and stiffness in the joints, collectively referred to as arthritis. Laboratory results of synovial
fluid analysis can be used to determine the pathologic origin
of arthritis. The beneficial tests most frequently performed on
synovial fluid are the white blood cell (WBC) count, differential, Gram stain, culture, and crystal examination.1 Reference
values are shown in Table 11–1.2
A variety of conditions including infection, inflammation,
metabolic disorders, trauma, physical stress, and advanced age
are associated with arthritis. Disorders are frequently classified
Normal Synovial Fluid Values2
Volume
Color
Clarity
Viscosity
Leukocyte count
Neutrophils
Crystals
Glucose:plasma
difference
Total protein
into four groups, as shown in Table 11–2. Some overlap of test
results among the groups may occur (Table 11–3)3; the
patient’s clinical history must also be considered when assigning
a category.
Specimen Collection and
Handling
Synovial fluid is collected by needle aspiration called arthrocentesis. The amount of fluid present varies with the size of
the joint and the extent of fluid buildup in the joint. For example, the normal amount of fluid in the adult knee cavity is
less than 3.5 mL, but can increase to greater than 25 mL with
inflammation. In some instances, only a few drops of fluid are
obtained, but these can still be used for microscopic analysis
or culturing. The volume of fluid collected should be recorded.
Table 11–2
Classification and Pathologic Significance
of Joint Disorders
Group
Classification
Pathologic
Significance
I. Noninflammatory
Degenerative joint disorders,
osteoarthritis
II. Inflammatory
Immunologic disorders, rheumatoid arthritis, systemic lupus
erythematosus, scleroderma,
polymyositis, ankylosing
spondylitis, rheumatic fever,
Lyme arthritis
Crystal-induced gout,
pseudogout
Microbial infection
Traumatic injury, tumors,
hemophilia, other coagulation
disorders
Anticoagulant overdose
Synovial membrane
Synovial cavity
containing synovial fluid
Articular cartilage
Articular capsule
Articulating bone
Figure 11–1 A synovial joint.
<3.5 mL
Colorless to pale yellow
Clear
Able to form a string 4 to 6 cm long
<200 cells/␮L
<25% of the differential
None present
<10 mg/dL lower than the blood
glucose level
<3 g/dL
III. Septic
IV. Hemorrhagic
3920_Ch11_217-228 23/01/14 10:34 AM Page 219
Chapter 11 | Synovial Fluid
Table 11–3
Laboratory Findings in Joint Disorders3
Table 11–4
219
Required Tube Types for Synovial Fluid Tests
Group
Classification
Laboratory
Findings
Synovial
Fluid Test
Required
Tube Type
I. Noninflammatory
Clear, yellow fluid
Good viscosity
WBCs <1000 ␮L
Neutrophils <30%
Similar to blood glucose
Gram stain and
culture
Cell counts
Sterile heparinized or sodium
polyanethol sulfonate
Heparin or liquid ethylenediaminetetraacetic acid (EDTA)
Sodium fluoride
Nonanticoagulated
II. Inflammatory
Immunologic origin
Crystal-induced
origin
III. Septic
IV. Hemorrhagic
Cloudy, yellow fluid
Poor viscosity
WBCs 2,000 to 75,000 ␮L
Neutrophils >50%
Decreased glucose level
Possible autoantibodies present
Cloudy or milky fluid
Low viscosity
WBCs up to 100,000 ␮L
Neutrophils <70%
Decreased glucose level
Crystals present
Cloudy, yellow-green fluid
Variable viscosity
WBCs 50,000 to 100,000 ␮L
Neutrophils >75%
Decreased glucose level
Positive culture and Gram stain
Cloudy, red fluid
Low viscosity
WBCs equal to blood
Neutrophils equal to blood
Normal glucose level
Glucose analysis
All other tests
TECHNICAL TIP Specimens for crystal analysis should
not be refrigerated because they can produce additional
crystals that can interfere with the identification of significant crystals.
Color and Clarity
A report of the gross appearance is an essential part of the
synovial fluid analysis. Normal synovial fluid appears colorless to pale yellow. The word “synovial” comes from the Latin
word for egg, ovum. Normal viscous synovial fluid resembles
egg white. The color becomes a deeper yellow in the presence
of noninflammatory and inflammatory effusions and may
have a greenish tinge with bacterial infection. As with cerebrospinal fluid, in synovial fluid the presence of blood from
a hemorrhagic arthritis must be distinguished from blood
from a traumatic aspiration. This is accomplished primarily
by observing the uneven distribution of blood or even a single blood streak in the specimens obtained from a traumatic
aspiration.
Turbidity is frequently associated with the presence of
WBCs; however, synovial cell debris and fibrin also produce turbidity. The fluid may appear milky when crystals are present.
Viscosity
Normal synovial fluid does not clot; however, fluid from a
diseased joint may contain fibrinogen and will clot. Therefore,
fluid is often collected in a syringe that has been moistened
with heparin. When sufficient fluid is collected, it should be
distributed into specific tubes based on the required tests, as
presented in Table 11–4.
Powdered anticoagulants should not be used because they
may produce artifacts that interfere with crystal analysis. The
nonanticoagulated tube for other tests must be centrifuged and
separated to prevent cellular elements from interfering with
chemical and serologic analyses. Ideally, all testing should be
done as soon as possible to prevent cellular lysis and possible
changes in crystals.
Synovial fluid viscosity comes from polymerization of the
hyaluronic acid and is essential for the proper joints lubrication.
Arthritis affects both the production of hyaluronate and its ability to polymerize, thus decreasing the fluid viscosity. Several
methods are available to measure the synovial fluid viscosity,
the simplest being to observe the fluid’s ability to form a string
from the tip of a syringe, a test that easily can be done at the
bedside. A string measuring 4 to 6 cm is considered normal.
Hyaluronate polymerization can be measured using a
Ropes, or mucin clot, test. When added to a solution of 2% to
5% acetic acid, normal synovial fluid forms a solid clot
surrounded by clear fluid. As the ability of the hyaluronate to
polymerize decreases, the clot becomes less firm, and the surrounding fluid increases in turbidity. The mucin clot test is
3920_Ch11_217-228 23/01/14 10:34 AM Page 220
220
Part Three | Other Body Fluids
reported in terms of good (solid clot), fair (soft clot), low (friable clot), and poor (no clot). The mucin clot test is not routinely performed, because all forms of arthritis decrease
viscosity and little diagnostic information is obtained. Formation of a mucin clot after adding acetic acid can be used to
identify a questionable fluid as synovial fluid.
Cell Counts
The total leukocyte count is the most frequently performed cell
count on synovial fluid. Red blood cell (RBC) counts are seldom
requested. To prevent cellular disintegration, counts should be
performed as soon as possible or the specimen should be refrigerated. Very viscous fluid may need to be pretreated by
adding one drop of 0.05% hyaluronidase in phosphate buffer
per milliliter of fluid and incubating at 37°C for 5 minutes.
Manual counts on thoroughly mixed specimens are done
using the Neubauer counting chamber. Clear fluids can usually
be counted undiluted, but dilutions are necessary when fluids
are turbid or bloody. Dilutions can be made using the procedure presented in Chapter 9; however, traditional WBC diluting fluid cannot be used because it contains acetic acid that
causes the formation of mucin clots. Normal saline can be used
as a diluent. If it is necessary to lyse the RBCs, hypotonic saline
(0.3%) or saline that contains saponin is a suitable diluent.
Methylene blue added to the normal saline stains the WBC nuclei, permitting separation of the RBCs and WBCs during
counts performed on mixed specimens.
The recommended technique is to line a petri dish with
moist paper and place the hemocytometer on two small sticks
to elevate it above the moist paper. Fill and count both sides
of the hemocytometer for compatibility. Acceptable ranges are
determined by the laboratory.
Counting procedure:
For counts less than 200 WBCs/␮L, count all 9 large squares.
For counts greater than 200 WBCs /␮L in the above count,
count the 4 corner squares.
For counts greater than 200 WBCs /␮L in the above count,
count the 5 small squares used for a RBC count.2
Table 11–5
Automated cell counters can be used for synovial fluid
counts; however, highly viscous fluid may block the apertures,
and the presence of debris and tissue cells may falsely elevate
counts. As described previously, incubating the fluid with
hyaluronidase decreases specimen viscosity. Analyzing scattergrams can aid in detecting tissue cells and debris. Properly controlled automated counts provide higher precision than manual
counts.4 (See Appendix A.)
WBC counts less than 200 cells/␮L are considered normal
and may reach 100,000 cells/␮L or higher in severe infections.5
There is, however, considerable overlap of elevated leukocyte
counts between septic and inflammatory forms of arthritis.
Pathogenicity of the infecting organisms also produces varying
results in septic arthritis, as does antibiotic administration.
Differential Count
Differential counts should be performed on cytocentrifuged
preparations or on thinly smeared slides. Fluid should be incubated with hyaluronidase prior to slide preparation.
Mononuclear cells, including monocytes, macrophages, and
synovial tissue cells, are the primary cells seen in normal
synovial fluid. Neutrophils should account for less than 25%
of the differential count and lymphocytes less than 15%.
Increased neutrophils indicate a septic condition, whereas
an elevated cell count with a predominance of lymphocytes
suggests a nonseptic inflammation. In both normal and
abnormal specimens, cells may appear more vacuolated than
they do on a blood smear.3 Besides increased numbers of
these usually normal cells, other cell abnormalities include
the presence of eosinophils, LE cells, Reiter cells (or neutrophages, vacuolated macrophages with ingested neutrophils), and RA cells (or ragocytes, neutrophils with small,
dark cytoplasmic granules consisting precipitated rheumatoid factor). Lipid droplets may be present after crush
injuries, and hemosiderin granules are seen in cases of pigmented villonodular synovitis. The most frequently encountered cells and inclusions seen in synovial fluid are summarized
in Table 11–5.
Cells and Inclusions Seen in Synovial Fluid
Cell/Inclusion
Description
Significance
Neutrophil
Polymorphonuclear leukocyte
Lymphocyte
Macrophage
(monocyte)
Mononuclear leukocyte
Large mononuclear leukocyte, may be vacuolated
Synovial lining cell
Similar to macrophage, but may be
multinucleated, resembling a mesothelial cell
LE cell
Neutrophil containing characteristic ingested
“round body”
Vacuolated macrophage with ingested neutrophils
Bacterial sepsis
Crystal-induced inflammation
Nonseptic inflammation
Normal
Viral infections
Normal
Disruption from arthrocentesis
Lupus erythematosus
Reiter cell
Reactive arthritis (infection in
another part of the body)
3920_Ch11_217-228 23/01/14 10:34 AM Page 221
Chapter 11 | Synovial Fluid
Table 11–5
Cells and Inclusions Seen in Synovial Fluid—cont’d
Cell/Inclusion
Description
Significance
RA cell (ragocyte)
Neutrophil with dark cytoplasmic granules
containing immune complexes
Cartilage cells
Rice bodies
Large, multinucleated cells
Macroscopically resemble polished rice
Microscopically show collagen and fibrin
Refractile intracellular and extracellular globules
Stain with Sudan dyes
Inclusions within clusters of synovial cells
Rheumatoid arthritis
Immunologic inflammation
Osteoarthritis
Tuberculosis
Septic and rheumatoid arthritis
Traumatic injury
Chronic inflammation
Pigmented villonodular synovitis
Fat droplets
Hemosiderin
Crystal Identification
Microscopic examination of synovial fluid for the presence
of crystals is an important diagnostic test in evaluating
arthritis. Crystal formation in a joint frequently results in an
acute, painful inflammation. It can also become a chronic
condition. Causes of crystal formation include metabolic
disorders and decreased renal excretion that produce elevated blood levels of crystallizing chemicals, degeneration
of cartilage and bone, and injection of medications, such as
corticosteroids, into a joint.
Types of Crystals
The primary crystals seen in synovial fluid are monosodium
urate (uric acid) (MSU), found in cases of gout, and calcium
pyrophosphate dihydrate (CPPD), seen with pseudogout. Increased serum uric acid resulting from impaired metabolism
Table 11–6
221
of purines; increased consumption of high-purine-content
foods, alcohol, and fructose; chemotherapy treatment of
leukemias; and decreased renal excretion of uric acid are the
most frequent causes of gout.5 Pseudogout is most often associated with degenerative arthritis, producing cartilage calcification and endocrine disorders that produce elevated serum
calcium levels.
Additional crystals that may be present include hydroxyapatite (basic calcium phosphate) associated with calcified cartilage
degeneration, cholesterol crystals associated with chronic inflammation, corticosteroids after injections, and calcium oxalate crystals in renal dialysis patients. Patient history must always be
considered. Characteristics and significance of the commonly
encountered crystals are presented in Table 11–6. Artifacts
present may include talcum powder and starch from gloves, precipitated anticoagulants, dust, and scratches on slides and cover
slips. Slides and cover slips should be examined and if necessary
cleaned again before use.
Characteristics of Synovial Fluid Crystals
Compensated
Polarized Light
Significance
Needles
Negative birefringence
Gout
Calcium
pyrophosphate
Rhomboid square, rods
Positive birefringence
Pseudogout
Cholesterol
Notched, rhomboid
plates
Negative birefringence
Extracellular
Crystal
Shape
Monosodium
urate
Image
Continued
3920_Ch11_217-228 23/01/14 10:34 AM Page 222
222
Part Three | Other Body Fluids
Table 11–6
Characteristics of Synovial Fluid Crystals—cont’d
Image
Compensated
Polarized Light
Crystal
Shape
Significance
Corticosteroid
Flat, variable-shaped
plates
Positive and negative
birefringence
Injections
Calcium oxalate
Envelopes
Negative birefringence
Renal dialysis
Apatite (calcium
phosphate)
Small particles
Require electron
microscopy
No birefringence
Osteoarthritis
Slide Preparation
Ideally, crystal examination should be performed soon after
fluid collection to ensure that crystals are not affected by
changes in temperature and pH. Both MSU and CPPD crystals
are reported as being located extracellularly and intracellularly
(within neutrophils); therefore, fluid must be examined before
WBC disintegration.
Fluid is examined as an unstained wet preparation. One
drop of fluid is placed on a precleaned glass slide and cover
slipped. The slide can be initially examined under low and high
power using a regular light microscope (Fig. 11–2). Crystals may
be observed in Wright’s-stained smears (Fig. 11–3); however,
this should not replace the wet prep examination and the use of
polarized and red-compensated polarized light for identification.
MSU crystals are routinely seen as needle-shaped crystals.
They may be extracellular or located within the cytoplasm of
neutrophils. They are frequently seen sticking through the
cytoplasm of the cell.
CPPD crystals usually appear rhomboid-shaped or square
but may appear as short rods. They are usually located within
vacuoles of the neutrophils, as shown in Figure 11–3. MSU
crystals lyse phagosome membranes and therefore do not
appear in vacuoles.6 To avoid misidentification of CPPD crystals, the classic rhomboid shape should be observed and confirmed with red compensated polarized microscopy.
Figure 11–2 Unstained wet prep of MSU crystals (×400). Notice the
characteristic yellow-brown of the urate crystals.
Crystal Polarization
Once the presence of the crystals has been determined using
direct polarization, positive identification is made using firstorder red-compensated polarized light. A control slide for the
polarization properties of MSU can be prepared using betamethasone acetate corticosteroid.
Figure 11–3 Wright's-stained neutrophils containing CPPD crystals
(×1000).
3920_Ch11_217-228 23/01/14 10:34 AM Page 223
Chapter 11 | Synovial Fluid
223
Both MSU and CPPD crystals have the ability to polarize
light, as discussed in Chapter 6; however, MSU is more highly
birefringent and appears brighter against the dark background
(Figs. 11–4 and 11–5).
When compensated polarized light is used, a red compensator is placed in the microscope between the crystal and the
analyzer. The compensator separates the light ray into slowmoving and fast-moving vibrations and produces a red background (Fig. 11–6).
Because of differences in the linear structure of the molecules
in MSU and CPPD crystals, the color produced by each crystal
when it is aligned with the slow vibration can be used to identify
the crystal. The molecules in MSU crystals run parallel to the long
axis of the crystal and, when aligned with the slow vibration, the
velocity of the slow light passing through the crystal is not impeded as much as the fast light, which runs against the grain and
produces a yellow color. This is considered negative birefringence
(subtraction of velocity from the fast ray). In contrast, the molecules in CPPD crystals run perpendicular to the long axis of the
crystal; when aligned with the slow axis of the compensator, the
velocity of the fast light passing through the crystal is much
quicker, producing a blue color and positive birefringence.7
When the crystals are aligned perpendicular to the slow vibration,
the color is reversed, as shown in Figure 11–6. Care must be
taken to ensure crystals being analyzed are aligned in accordance
with the compensator axis. Notice how the colors of the MSU
crystals in Figure 11–6 vary with the alignment. Figures 11–7
and 11–8 illustrate the characteristics of MSU and CPPD crystals
under compensated polarized light.
Figure 11–4 Strongly birefringent MSU crystals under polarized light
(×500).
Figure 11–7 MSU crystals under compensated polarized light. The
yellow crystal is aligned with the slow vibration (×500).
Figure 11–5 Weakly birefringent CPPD crystals under polarized light
(×1000).
Figure 11–8 CPPD crystals under compensated polarized light. The
blue crystal is aligned with the slow vibration (×1000).
Figure 11–6 Extracellular MSU crystals under compensated polarized
light. Notice the change in color with crystal alignment (×100).
3920_Ch11_217-228 23/01/14 10:34 AM Page 224
224
Part Three | Other Body Fluids
Crystal shapes and patterns of birefringence that vary from
the standard MSU and CPPD patterns may indicate the presence of one of the less commonly encountered crystals and that
further investigation is required (Fig. 11–9). Cholesterol,
oxalate, and corticosteroid crystals exhibit birefringence, as do
many contaminants. Apatite crystals are not birefringent.5
Chemistry Tests
S
ga low
in ra
st
gr y
ai
n)
(a
(w Slow
ith r
gr ay
ai
n)
Because synovial fluid is chemically an ultrafiltrate of plasma,
chemistry test values are approximately the same as serum
values. Therefore, few chemistry tests are considered clinically important. The most frequently requested test is the glucose determination, because markedly decreased glucose
values indicate inflammatory (group II) or septic (group III)
disorders. Because normal synovial fluid glucose values are
based on the blood glucose level, simultaneous blood and
synovial fluid samples should be obtained, preferably after
the patient has fasted for 8 hours to allow equilibration between the two fluids. Under these conditions, normal synovial fluid glucose should not be more than 10 mg/dL lower
than the blood value.
A
Other chemistry tests that may be requested are the total
protein and uric acid determinations. Because the large protein
molecules are not filtered through the synovial membranes, normal synovial fluid contains less than 3 g/dL protein (approximately one third of the serum value). Increased levels are found
in inflammatory and hemorrhagic disorders; however, synovial
fluid protein measurement does not contribute greatly to the
classification of these disorders. When requested, the analysis is
performed using the same methods used for serum protein determinations. The elevation of serum uric acid in cases of gout
is well known; therefore, demonstration of an elevated synovial
fluid uric acid level may be used to confirm the diagnosis when
the presence of crystals cannot be demonstrated in the fluid.
Serum uric acid is often measured as a first evaluation in suspected cases of gout. Fluid analysis for crystals is frequently still
required. Fluid lactate or acid phosphatase levels maybe requested to monitor the severity and prognosis of rheumatoid
arthritis (RA).2
Microbiologic Tests
An infection may occur as a secondary complication of inflammation caused by trauma or through dissemination of a systemic
infection; therefore, Gram stains and cultures are two of the most
important tests performed on synovial fluid. Both tests must be
performed on all specimens, as organisms are often missed on
Gram stain. Bacterial infections are most frequently seen; however, fungal, tubercular, and viral infections also can occur.
When they are suspected, special culturing procedures should
be used. Patient history and other symptoms can aid in requests
for additional testing. Routine bacterial cultures should include
an enrichment medium, such as chocolate agar, because in addition to Staphylococcus and Streptococcus, the common organisms that infect synovial fluid are the fastidious Haemophilus
species and Neisseria gonorrhoeae.
S
(w low
ith ra
gr y
ain
)
(ag Slo
ain w ra
st y
gra
in)
Serologic Tests
B
Figure 11–9 Negative and positive birefringence in MSU and CPPD
crystals. (A) MSU crystal with grain running parallel to the long axis.
The slow ray passes with the grain, producing negative (yellow) birefringence. (B) CPPD crystal with grain running perpendicular to the
long axis. The slow ray passes against the grain and is retarded, producing positive (blue) birefringence.
TECHNICAL TIP To prevent falsely decreased values
caused by glycolysis, specimens should be analyzed within
1 hour or preserved with sodium fluoride.
Because of the association of the immune system to the inflammation process, serologic testing plays an important role in the
diagnosis of joint disorders. However, most of these tests are performed on serum, and synovial fluid analysis actually serves as a
confirmatory measure in cases that are difficult to diagnose. The
autoimmune diseases rheumatoid arthritis and systemic lupus
erythematosus cause very serious joint inflammation and are diagnosed in the serology laboratory by demonstrating the presence
of their particular autoantibodies in the patient’s serum. These
same antibodies can also be demonstrated in synovial fluid, if
necessary. Arthritis is a frequent complication of Lyme disease.
Therefore, demonstrating antibodies to the causative agent Borrelia burgdorferi in the patient’s serum can confirm the cause of
the arthritis.
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
3920_Ch11_217-228 23/01/14 10:34 AM Page 225
Chapter 11 | Synovial Fluid
References
1. Shmerling, RH: Synovial fluid analysis. A critical reappraisal.
Rheum Dis Clin North Am 20(2):503–512, 1994.
2. Clinical and Laboratory Science Institute (CLSI): Analysis of
Body Fluids in Clinical Chemistry, Approved Guideline, C49-A,
Wayne, PA, 2007, CLSI.
3. Smith, GP, and Kjeldsberg, CR: Cerebrospinal, synovial, and serous
body fluids. In Henry, JB (ed): Clinical Diagnosis and Management
by Laboratory Methods. WB Saunders, Philadelphia, 2001.
225
4. Brown, W, et al: Validation of body fluid analysis on the Coulter
LH 750. Lab Hem 9(3):155–159, 2004.
5. Schumacher, HD, Clayburne, G, and Chen, L: Synovial fluid
aspiration and analysis in evaluation of gout and other crystalinduced diseases. Arthritis Foundation: Bulletin on the
Rheumatic Diseases 53(3), 2004.
6. Harris, MD, Siegel, LB, and Alloway, JA: Gout and hyperuricemia.
Am Fam Physician 59(4):925–934, 1999.
7. Cornbleet, PJ: Synovial fluid crystal analysis. Lab Med 28(12):
774–779, 1997.
Study Questions
1. The functions of synovial fluid include all of the following
except:
A. Lubrication for the joints
B. Removal of cartilage debris
C. Cushioning joints during jogging
D. Providing nutrients for cartilage
2. The primary function of synoviocytes is to:
A. Provide nutrients for the joints
B. Secrete hyaluronic acid
C. Regulate glucose filtration
D. Prevent crystal formation
3. Which of the following is not a frequently performed test
on synovial fluid?
A. Uric acid
B. WBC count
C. Crystal examination
D. Gram stain
4. The procedure for collecting synovial fluid is called:
A. Synovialcentesis
B. Arthrocentesis
C. Joint puncture
D. Arteriocentesis
5. Match the following disorders with their appropriate group:
A. Noninflammatory
B. Inflammatory
C. Septic
D. Hemorrhagic
____ Gout
____ Neisseria gonorrhoeae infection
____ Systemic lupus erythematosus
____ Osteoarthritis
____ Hemophilia
____ Rheumatoid arthritis
____ Heparin overdose
6. Normal synovial fluid resembles:
A. Egg white
B. Normal serum
C. Dilute urine
D. Lipemic serum
7. Before testing, very viscous synovial fluid should be
treated with:
A.
B.
C.
D.
Normal saline
Hyaluronidase
Distilled water
Hypotonic saline
8. Addition of a cloudy, yellow synovial fluid to acetic acid
produces a/an:
A. Yellow-white precipitate
B. Easily dispersed clot
C. Solid clot
D. Opalescent appearance
9. Which of the following could be the most significantly
affected if a synovial fluid is refrigerated before testing?
A. Glucose
B. Crystal examination
C. Mucin clot test
D. Differential
10. The highest WBC count can be expected to be seen with:
A.
B.
C.
D.
Noninflammatory arthritis
Inflammatory arthritis
Septic arthritis
Hemorrhagic arthritis
11. When diluting a synovial fluid WBC count, all of the
following are acceptable except:
A. Acetic acid
B. Isotonic saline
C. Hypotonic saline
D. Saline with saponin
3920_Ch11_217-228 23/01/14 10:34 AM Page 226
226
Part Three | Other Body Fluids
12. The lowest percentage of neutrophils would be seen in:
A. Noninflammatory arthritis
B. Inflammatory arthritis
C. Septic arthritis
D. Hemorrhagic arthritis
13. All of the following are abnormal when seen in synovial
fluid except:
A. Neutrophages
B. Ragocytes
C. Synovial lining cells
D. Lipid droplets
14. Synovial fluid crystals that occur as a result of purine
metabolism or chemotherapy for leukemia are:
A. Monosodium urate
B. Cholesterol
C. Calcium pyrophosphate
D. Apatite
15. Synovial fluid crystals associated with inflammation in
dialysis patients are:
A. Calcium pyrophosphate dihydrate
B. Calcium oxalate
C. Corticosteroid
D. Monosodium urate
16. Crystals associated with pseudogout are:
A. Monosodium urate
B. Calcium pyrophosphate dihydrate
C. Apatite
D. Corticosteroid
17. Synovial fluid for crystal examination should be examined
as a/an:
A. Wet preparation
B. Wright's stain
C. Gram stain
D. Acid-fast stain
18. Crystals that have the ability to polarize light are:
A. Corticosteroid
B. Monosodium urate
C. Calcium oxalate
D. All of the above
19. In an examination of synovial fluid under compensated
polarized light, rhomboid-shaped crystals are observed.
What color would these crystals be when aligned parallel
to the slow vibration?
A. White
B. Yellow
C. Blue
D. Red
20. If crystals shaped like needles are aligned perpendicular
to the slow vibration of compensated polarized light, what
color are they?
A. White
B. Yellow
C. Blue
D. Red
21. Negative birefringence occurs under red-compensated polarized light when:
A. Slow light is impeded more than fast light
B. Slow light is less impeded than fast light
C. Fast light runs against the molecular grain of the
crystal
D. Both B and C
22. Synovial fluid cultures are often plated on chocolate agar
to detect the presence of:
A. Neisseria gonorrhoeae
B. Staphylococcus agalactiae
C. Streptococcus viridans
D. Enterococcus faecalis
23. The most frequently performed chemical test on synovial
fluid is:
A. Total protein
B. Uric acid
C. Calcium
D. Glucose
24. Which of the following chemistry tests can be performed
on synovial fluid to determine the severity of RA?
A. Glucose
B. Protein
C. Lactate
D. Uric acid
25. Serologic tests on patients’ serum may be performed to
detect antibodies causing arthritis for all of the following
disorders except:
A. Pseudogout
B. Rheumatoid arthritis
C. Systemic lupus erythematosus
D. Lyme arthritis
3920_Ch11_217-228 23/01/14 10:34 AM Page 227
Chapter 11 | Synovial Fluid
227
Case Studies and Clinical Situations
1. A 50-year-old man presents in the emergency department
with severe pain and swelling in the right knee. Arthrocentesis is performed and 20 mL of milky synovial fluid is
collected. The physician orders a Gram stain, culture, and
crystal examination of the fluid, as well as a serum uric
acid. She requests that the synovial fluid be saved for
possible additional tests.
a. Describe the tubes into which the fluid would be
routinely placed.
b. If the patient’s serum uric acid level is elevated, what
type of crystals and disorder are probable?
c. Describe the appearance of these crystals under direct
and compensated polarized light.
d. Why were the Gram stain and culture ordered?
2. A medical laboratory science student dilutes a synovial
fluid sample before performing a WBC count. The fluid
forms a clot.
a. Why did the clot form?
b. How can the student perform a correct dilution of the
fluid?
c. After the correct dilution is made, the WBC count is
100,000/␮L. State two arthritis classifications that
could be considered.
d. State two additional tests that could be run to
determine the classification.
3. Fluid obtained from the knee of an obese 65-year-old
woman being evaluated for a possible knee replacement
has the following results:
APPEARANCE: Pale yellow and hazy
WBC COUNT: 500 cells/␮L
GRAM STAIN: Negative
GLUCOSE: 110 mg/dL (serum glucose: 115 mg/dL)
a. What classification of joint disorder do these results
suggest?
b. Under electron microscopy, what crystals might be
detected?
c. How does the glucose result aid in the disorder
classification?
4. A synovial fluid sample delivered to the laboratory for a
cell count is clotted.
a. What abnormal constituent is present in the fluid?
b. What type of tube should be sent to the laboratory for
a cell count?
c. Could the original tube be used for a Gram stain and
culture? Why or why not?
3920_Ch11_217-228 23/01/14 10:34 AM Page 228
3920_Ch12_229-242 23/01/14 10:35 AM Page 229
CHAPTER
12
Serous Fluid
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
12-1 Describe the normal formation of serous fluid.
12-2 Describe four primary causes of serous effusions.
12-3 Differentiate between a transudate and an exudate,
including etiology, appearance, and laboratory tests.
12-4 Differentiate between a hemothorax and a hemorrhagic
exudate.
12-5 Differentiate between a chylous and a pseudochylous
exudate.
12-6 State the significance of increased neutrophils,
lymphocytes, eosinophils, and plasma cells in
pleural fluid.
12-7 Describe the morphologic characteristics of mesothelial cells and malignant cells.
12-8 List three common chemistry tests performed on
pleural fluid, and state their significance.
12-9 State the common etiologies of pericardial effusions.
12-10 Discuss the diagnostic significance of peritoneal
lavage.
12-11 Calculate a serum-ascites gradient, and state its
significance.
12-12 Differentiate between ascitic effusions of hepatic and
peritoneal origin.
12-13 State the clinical significance of the carcinoembryonic
antigen and CA 125 tests.
12-14 List four chemical tests performed on ascitic fluid,
and state their significance.
KEY TERMS
Ascites
Paracentesis
Ascitic fluid
Parietal membrane
Serum-ascites albumin gradient
(SAAG)
Effusion
Pericardiocentesis
Thoracentesis
Exudate
Pericarditis
Transudate
Hydrostatic pressure
Peritonitis
Visceral membrane
Oncotic pressure
Serous fluid
3920_Ch12_229-242 23/01/14 10:35 AM Page 230
230
Part Three | Other Body Fluids
The closed cavities of the body—namely, the pleural, pericardial, and peritoneal cavities—are each lined by two membranes referred to as the serous membranes. One membrane
lines the cavity wall (parietal membrane), and the other
covers the organs within the cavity (visceral membrane)
(Fig. 12–1). The fluid between the membranes is called
serous fluid, and it provides lubrication between the parietal
and visceral membranes. Lubrication is necessary to prevent
the friction between the two membranes that occurs as a
result of movement of the enclosed organs, such as in the
expansion and contraction of the lungs. Normally, only a
small amount of serous fluid is present, because production
and reabsorption take place at a constant rate.
pressure in the parietal and visceral capillaries creates a small
excess of fluid that is reabsorbed by the lymphatic capillaries
located in the membranes. In Figure 12–2, the normal formation and absorption of pleural fluid are demonstrated.
Disruption of the mechanisms of serous fluid formation
and reabsorption causes an increase in fluid between the membranes. This increase is termed an effusion. Primary causes of
effusions include increased hydrostatic pressure (congestive
heart failure), decreased oncotic pressure (hypoproteinemia),
increased capillary permeability (inflammation and infection),
and lymphatic obstruction (tumors) (Table 12–1).
Specimen Collection
and Handling
Formation
Serous fluids are formed as ultrafiltrates of plasma; no additional
material is contributed by the mesothelial cells that line the
membranes. Production and reabsorption are subject to hydrostatic pressure and colloidal pressure (oncotic pressure) from
the capillaries that serve the cavities and the capillary permeability. Under normal conditions, colloidal pressure from serum
proteins is the same in the capillaries on both sides of the membrane. Therefore, hydrostatic pressure in the parietal and visceral capillaries causes fluid to enter between the membranes.
Filtration of the plasma ultrafiltrate results in increased oncotic
pressure in the capillaries that favors reabsorption of fluid back
into the capillaries. This action produces a continuous exchange
of serous fluid and maintains the normal volume of fluid between the membranes. The slightly different amount of positive
Parietal
pericardium
Pericardial
cavity
Visceral
pericardium
Fluids for laboratory examination are collected by needle aspiration from the respective cavities. These aspiration procedures
are referred to as thoracentesis (pleural), pericardiocentesis
(pericardial), and paracentesis (peritoneal). Abundant fluid
(>100 mL) is usually collected; therefore, suitable specimens
are available for each section of the laboratory.
An EDTA tube is used for cell counts and the differential.
Sterile heparinized or sodium polyanethol sulfonate (SPS)
evacuated tubes are used for microbiology and cytology. For
better recovery of microorganisms and abnormal cells, concentration of large amounts of fluid is performed by centrifugation. Chemistry tests can be run on clotted specimens in
plain tubes or in heparin tubes. Specimens for pH must be
maintained anaerobically in ice.1 Chemical tests performed on
Parietal pleura
Pleural cavity
Visceral pleura
Lung
Body wall
Liver
Stomach
Parietal
peritoneum
Visceral
peritoneum
Intestine
Peritoneal
cavity
Figure 12–1 The body areas and membranes where
serous fluid is produced.
3920_Ch12_229-242 23/01/14 10:35 AM Page 231
Chapter 12 | Serous Fluid
serous fluids are frequently compared with plasma chemical
concentrations because the fluids are essentially plasma ultrafiltrates. Therefore, blood specimens should be obtained at
the time of collection.
Parietal
pleura
Chest
wall
Visceral
pleura
Pleural
space
Lung
Systemic
capillary
Pulmonary
capillary
Oncotic
pressure
Oncotic
pressure
(mm Hg)
– 26
26 +
Hydrostatic
pressure
(mm Hg)
+30
Intrapleural
pressure
Hydrostatic
pressure
+5
+9
–5
+10
–11
Intrapleural
pressure
Lymphatic system
231
Transudates and Exudates
A general classification of the cause of an effusion can be
accomplished by categorizing the fluid as either transudate or
exudate. Effusions that form because of a systemic disorder that
disrupts the balance in the regulation of fluid filtration and reabsorption—such as the changes in hydrostatic pressure created
by congestive heart failure or the hypoproteinemia associated
with the nephrotic syndrome—are called transudates. Exudates
are produced by conditions that directly involve the membranes
of the particular cavity, including infections and malignancies.
Classifying a serous fluid as a transudate or exudate can provide
a valuable initial diagnostic step and aid in the course of further
laboratory testing, because it is usually not necessary to test
transudate fluids.2 Traditionally, a variety of laboratory tests have
been used to differentiate between transudates and exudates, including appearance, total protein, lactic dehydrogenase, cell
counts, and spontaneous clotting. However, the most reliable
differentiation is usually obtained by determining the fluid:
blood ratios for protein and lactic dehydrogenase.3 Differential
values for these parameters are shown in Table 12–2. Additional
tests are available for specific fluids and will be discussed in the
following sections.
General Laboratory
Procedures
Serous fluid examination—including classification as a transudate or exudate; appearance; cell count and differential;
and chemistry, microbiology, and cytology procedures—is
Figure 12–2 The normal formation and absorption of pleural fluid.
Table 12–2
Table 12–1
Laboratory Differentiation of Transudates
and Exudates
Pathologic Causes of Effusions
Increased capillary hydrostatic pressure
Congestive heart failure
Salt and fluid retention
Decreased oncotic pressure
Nephrotic syndrome
Hepatic cirrhosis
Malnutrition
Protein-losing enteropathy
Increased capillary permeability
Microbial infections
Membrane inflammations
Malignancy
Lymphatic obstruction
Malignant tumors, lymphomas
Infection and inflammation
Thoracic duct injury
Appearance
Fluid:serum
protein ratio
Fluid:serum LD
ratio
WBC count
Spontaneous
clotting
Pleural fluid
cholesterol
Pleural fluid:
serum cholesterol ratio
Pleural fluid:
bilirubin ratio
Serum-ascites
albumin
gradient
Transudate
Exudate
Clear
<0.5
Cloudy
>0.5
<0.6
>0.6
<1000/µL
No
>1000/µL
Possible
<45 to
60 mg/dL
<0.3
>45 to
60 mg/dL
>0.3
<0.6
>0.6
>1.1
<1.1
3920_Ch12_229-242 23/01/14 10:35 AM Page 232
232
Part Three | Other Body Fluids
performed in the same manner on all serous fluids. However,
the significance of the test results and the need for specialized
tests vary among fluids. Therefore, the interpretation of routine and special procedures will be discussed individually for
each of the three serous fluids.
Tests that are usually performed on all serous fluids include
evaluation of the appearance and differentiation between a transudate and an exudate. Effusions of exudative origin are then
examined for the presence of microbiologic and cytologic
abnormalities. Additional tests are ordered based on specific
clinical symptoms. Red blood cell (RBC) and white blood cell
(WBC) counts are not routinely performed on serous fluids because they provide little diagnostic information.4 In general,
WBC counts greater than 1000/␮L and RBC counts greater than
100,000/␮L indicate an exudate. Serous fluid cell counts can be
performed manually by using a Neubauer counting chamber
and the methods discussed in Chapter 9 or by electronic cell
counters (see Appendix A). When manual cell counts are performed, they frequently include a count of all nucleated cells.1
Inclusion of tissue cells and debris in the count must be considered when electronic counters are used, and care must be taken
to prevent the blocking of tubing with debris.
Differential cell counts are routinely performed on serous
fluids, preferably on Wright’s-stained, cytocentrifuged specimens or on slides prepared from the sediment of centrifuged
specimens. Smears must be examined not only for WBCs, but
also for normal and malignant tissue cells. Any suspicious cells
seen on the differential are referred to the cytology laboratory
or the pathologist.
Pleural Fluid
Pleural fluid is obtained from the pleural cavity, located between the parietal pleural membrane lining the chest wall and
the visceral pleural membrane covering the lungs. Pleural effusions may be either transudative or exudative. In addition to
the tests routinely performed to differentiate between transudates and exudates, two additional procedures are helpful
when analyzing pleural fluid: the pleural fluid cholesterol and
fluid:serum cholesterol ratio and the pleural fluid:serum total
bilirubin ratio. A pleural fluid cholesterol >60 mg/dL or a pleural fluid:serum cholesterol ratio >0.3 provides reliable information that the fluid is an exudate.5 A fluid:serum total
bilirubin ratio of 0.6 or more also indicates the presence of an
exudate.
Appearance
Considerable diagnostic information concerning the etiology
of a pleural effusion can be learned from the specimen appearance (Table 12–3). Normal and transudate pleural fluids
are clear and pale yellow. Turbidity is usually related to the
presence of WBCs and indicates bacterial infection, tuberculosis, or an immunologic disorder such as rheumatoid arthritis. The presence of blood in the pleural fluid can signify a
hemothorax (traumatic injury), membrane damage such as
occurs in malignancy, or a traumatic aspiration. As seen with
Table 12–3
Appearance
Correlation of Pleural Fluid Appearance
and Disease5
Disorder
Clear, pale yellow Normal
Turbid, white
Microbial infection (tuberculosis)
Bloody
Hemothorax
Hemorrhagic effusion, pulmonary
embolus, tuberculosis, malignancy
Milky
Chylous material from thoracic duct
leakage
Pseudochylous material from chronic
inflammation
Brown
Rupture of amoebic liver abscess
Black
Aspergillus
Viscous
Malignant mesothelioma (increased
hyaluronic acid)
other fluids, blood from a traumatic tap appears streaked and
uneven.
To differentiate between a hemothorax and hemorrhagic
exudate, a hematocrit can be run on the fluid. If the blood is
from a hemothorax, the fluid hematocrit is more than 50% of
the whole blood hematocrit, because the effusion comes from
the inpouring of blood from the injury.6 A chronic membrane
disease effusion contains both blood and increased pleural
fluid, resulting in a much lower hematocrit.
The appearance of a milky pleural fluid may be due to the
presence of chylous material from thoracic duct leakage or to
pseudochylous material produced in chronic inflammatory
conditions. Chylous material contains a high concentration of
triglycerides, whereas pseudochylous material has a higher concentration of cholesterol. Therefore, Sudan III staining is
strongly positive with chylous material. In contrast, pseudochylous effusions contain cholesterol crystals.5 Differentiation between chylous and pseudochylous effusions is summarized in
Table 12–4.
Hematology Tests
As mentioned previously, the differential cell count is the most
diagnostically significant hematology test performed on serous
fluids. Primary cells associated with pleural fluid include
macrophages, neutrophils, lymphocytes, eosinophils, mesothelial cells, plasma cells, and malignant cells. Macrophages normally account for 64% to 80% of a nucleated cell count
followed by lymphocytes (18% to 30%) and neutrophils
(1% to 2%) (Table 12–5). These same cells are also found in
pericardial and peritoneal fluids.
Similar to other body fluids, an increase in pleural fluid
neutrophils indicates a bacterial infection, such as pneumonia.
Neutrophils are also increased in effusions resulting from pancreatitis and pulmonary infarction.
3920_Ch12_229-242 23/01/14 10:35 AM Page 233
Chapter 12 | Serous Fluid
Table 12–4
Differentiation Between Chylous
and Pseudochylous Pleural Effusions
Chylous Effusion
Cause
Thoracic duct
damage
Appearance
Leukocytes
Milky/white
Predominantly
lymphocytes
Absent
Cholesterol
crystals
Triglycerides
Sudan III
staining
Table 12–5
233
>110 mg/dL
Strongly positive
Pseudochylous
Effusion
Chronic
inflammation
Lymphatic
obstruction
Milky/green tinge
Mixed cells
Present
<50 mg/dL
Negative/weakly
positive
Significance of Cells Seen in Pleural Fluid
Cells
Significance
Neutrophils
Pancreatitis
Pulmonary infarction
Tuberculosis
Viral infection
Autoimmune disorders
Malignancy
Normal and reactive forms have
no clinical significance
Decreased mesothelial cells are
associated with tuberculosis
Tuberculosis
Primary adenocarcinoma and
small-cell carcinoma
Metastatic carcinoma
Lymphocytes
Mesothelial cells
Plasma cells
Malignant cells
Lymphocytes are normally noticeably present in both transudates and exudates in a variety of forms, including small,
large, and reactive. More prominent nucleoli and cleaved nuclei may be present. Elevated lymphocyte counts are seen in
effusions resulting from tuberculosis, viral infections, malignancy, and autoimmune disorders such as rheumatoid arthritis
and systemic lupus erythematosus. Systemic lupus erythematosus cells may be seen (Fig. 12–3).
Increased eosinophil levels (>10%) may be associated with
trauma resulting in the presence of air or blood (pneumothorax
and hemothorax) in the pleural cavity. They are also seen in
allergic reactions and parasitic infections.
Figure 12–3 Systemic lupus erythematosus cell in pleural fluid. Notice
the ingested “round body” (×1000).
The membranes lining the serous cavities contain a single
layer of mesothelial cells, so it is not unusual to find these cells
in the serous fluids. Mesothelial cells are pleomorphic; they
resemble lymphocytes, plasma cells, and malignant cells, frequently making identification difficult. They often appear as
single small or large round cells with abundant blue cytoplasm
and round nuclei with uniform dark purple cytoplasm and
may be referred to as “normal” mesothelial cells (Figs. 12–4
and 12–5). In contrast, “reactive” mesothelial cells may appear
in clusters; have varying amounts of cytoplasm, eccentric nuclei, and prominent nucleoli; and be multinucleated, thus more
closely resembling malignant cells (Figs. 12–6 and 12–7). An
increase in mesothelial cells is not a diagnostically significant
finding, but they may be increased in pneumonia and malignancy. Of more significance is the noticeable lack of mesothelial
cells associated with tuberculosis, which results from exudate
covering the pleural membranes. Also associated with tuberculosis is an increase in the presence of pleural fluid plasma
cells (Fig. 12–8).
A primary concern in examining all serous effusions is
detecting malignant cells. Differentiating among mesothelial
cells and other tissue cells and malignant cells is often
Figure 12–4 Normal pleural fluid mesothelial cells, lymphocytes, and
monocytes (×250).
3920_Ch12_229-242 23/01/14 10:35 AM Page 234
234
Part Three | Other Body Fluids
Figure 12–5 Normal mesothelial cell (×500).
Figure 12–6 Reactive mesothelial cells showing eccentric nuclei and
vacuolated cytoplasm (×500).
Figure 12–7 One normal and two reactive mesothelial cells with a
multinucleated form (×500).
difficult. Distinguishing characteristics of malignant cells
may include nuclear and cytoplasmic irregularities, hyperchromatic nucleoli, cellular clumps with cytoplasmic molding (community borders), and abnormal nucleus:cytoplasm
ratios (Figs. 12–9 to 12–11). Malignant pleural effusions
most frequently contain large, irregular adenocarcinoma
Figure 12–8 Pleural fluid plasma cells seen in a case of tuberculosis.
Notice the absence of mesothelial cells (×1000).
Figure 12–9 Pleural fluid adenocarcinoma showing cytoplasmic
molding (×250).
Figure 12–10 Pleural fluid adenocarcinoma showing nuclear and cytoplasmic molding and vacuolated cytoplasm (×1000).
cells, small or oat cell carcinoma cells resembling large lymphocytes, and clumps of metastatic breast carcinoma cells
(Figs. 12–12 to 12–14). Special staining techniques and flow
cytometry may be used for positive identification of tumor
cells. Table 12–6 describes the primary characteristics of
malignant serous fluid cells.
3920_Ch12_229-242 23/01/14 10:35 AM Page 235
Chapter 12 | Serous Fluid
Figure 12–11 Enhancement of nuclear irregularities using a toluidine
blue stain (×250).
Figure 12–14 Metastatic breast carcinoma cells in pleural fluid. Notice
the hyperchromatic nucleoli (×1000).
Table 12–6
Figure 12–12 Poorly differentiated pleural fluid adenocarcinoma
showing nuclear irregularities and cytoplasmic vacuoles (×500).
Chemistry Tests
In addition to the chemical tests performed to differentiate between a pleural transudate and a pleural exudate, the most
common chemical tests performed on pleural fluid are glucose,
pH, adenosine deaminase (ADA), and amylase (Table 12–7).
Characteristics of Malignant Cells
Increased nucleus:cytoplasm (N:C) ratio. The higher
the ratio, the more poorly differentiated are the
cells.
Irregularly distributed nuclear chromatin
Variation in size and shape of nuclei
Increased number and size of nucleoli
Hyperchromatic nucleoli
Giant cells and multinucleation
Nuclear molding
Cytoplasmic molding (community borders)
Vacuolated cytoplasm, mucin production
Cellular crowding, phagocytosis
Table 12–7
Figure 12–13 Pleural fluid small cell carcinoma showing nuclear
molding (×250).
235
Significance of Chemical Testing of
Pleural Fluid
Test
Significance
Glucose
Decreased in rheumatoid
inflammation
Decreased in purulent infection
Elevated in bacterial infection
Elevated in chylous effusions
Decreased in pneumonia not
responding to antibiotics
Markedly decreased with esophageal
rupture
Elevated in tuberculosis and
malignancy
Elevated in pancreatitis, esophageal
rupture, and malignancy
Lactate
Triglyceride
pH
ADA
Amylase
3920_Ch12_229-242 23/01/14 10:35 AM Page 236
236
Part Three | Other Body Fluids
Triglyceride levels may also be measured to confirm the presence of a chylous effusion.
Decreased glucose levels are seen with tuberculosis,
rheumatoid inflammation, and purulent infections. As an ultrafiltrate of plasma, pleural fluid glucose levels parallel plasma
levels, and values less than 60 mg/dL are considered decreased.
Fluid values should be compared with plasma values. Pleural
fluid lactate levels are elevated in bacterial infections and can
be considered in addition to the glucose level.
Pleural fluid pH lower than 7.2 may indicate the need
for chest-tube drainage, in addition to administration of
antibiotics in cases of pneumonia. In cases of acidosis, the
pleural fluid pH should be compared with the blood pH.
Pleural fluid pH at least 0.30 degrees lower than the blood
pH is considered significant.7 A pH value as low as 6.0 indicates an esophageal rupture that is allowing the influx of
gastric fluid.
ADA levels higher than 40 U/L are highly indicative of tuberculosis. They are also frequently elevated with malignancy.
As with serum, elevated amylase levels are associated with
pancreatitis, and amylase is often elevated first in the pleural
fluid. Pleural fluid amylase, including salivary amylase, may
also be elevated in esophageal rupture and malignancy.
Microbiologic and Serologic Tests
Microorganisms primarily associated with pleural effusions
include Staphylococcus aureus, Enterobacteriaceae, anaerobes,
and Mycobacterium tuberculosis. Gram stains, cultures (both
aerobic and anaerobic), acid-fast stains, and mycobacteria
cultures are performed on pleural fluid when clinically
indicated.
Serologic testing of pleural fluid is used to differentiate
effusions of immunologic origin from noninflammatory
processes. Tests for antinuclear antibody (ANA) and rheumatoid factor (RF) are the most frequently performed.
Detection of the tumor markers carcinoembryonic
antigen (CEA), CA 125 (metastatic uterine cancer), CA 15.3
and CA 549 (breast cancer), and CYFRA 21-1 (lung cancer)
provide valuable diagnostic information in effusions of
malignant origin.8
Pleural fluid testing and its significance are summarized
in Figure 12–15.
Pericardial Fluid
Normally, only a small amount (10 to 50 mL) of fluid is
found between the pericardial serous membranes. Pericardial
effusions are primarily the result of changes in the membrane
permeability due to infection (pericarditis), malignancy, and
trauma-producing exudates. Metabolic disorders such as
uremia, hypothyroidism, and autoimmune disorders are the
primary causes of transudates. An effusion is suspected when
cardiac compression (tamponade) is noted during the physician’s examination (Table 12–8.).
PLEURAL FLUID TESTING ALGORITHM
Fluid protein and LD
Fluid:serum protein >0.5
Fluid:serum LD >0.6
Fluid LD > 2/3 upper normal serum value
Appearance
Bloody
Milky
Hematocrit
Triglycerides
Any positive
No
Yes
Transudate
Exudate
Glucose
ADA
WBC/Diff
Amylase
pH
ADA >40 U/L
WBC/Diff
Amylase
pH
Lymphocytosis
>300/µ L
Granulocytosis
Elevated
<7.2
<6.0
Tuberculosis
Bacterial infection
Pancreatitis
Possible
need for
chest tubes
Esophageal
rupture
Figure 12–15 Algorithm of pleural fluid testing.
3920_Ch12_229-242 23/01/14 10:35 AM Page 237
Chapter 12 | Serous Fluid
Table 12–8
237
Significance of Pericardial Fluid Testing
Test
Significance
Appearance
Clear, pale yellow
Blood-streaked
Grossly bloody
Milky
Normal, transudate
Infection, malignancy
Cardiac puncture,
anticoagulant
medications
Chylous and
pseudochylous
material
Additional testing
Increased neutrophils
Malignant cells
Carcinoembryonic antigen
Gram stain and culture
Acid-fast stain
Adenosine deaminase
Bacterial endocarditis
Metastatic carcinoma
Metastatic carcinoma
Bacterial endocarditis
Tubercular effusion
Tubercular effusion
Appearance
Normal and transudate pericardial fluid appears clear and pale
yellow. Effusions resulting from infection and malignancy are
turbid, and malignant effusions are frequently blood streaked.
Grossly bloody effusions are associated with accidental cardiac
puncture and misuse of anticoagulant medications. Milky
fluids representing chylous and pseudochylous effusions may
also be present.
Laboratory Tests
Tests performed on pericardial fluid are primarily directed
at determining whether the fluid is a transudate or an exudate and include the fluid:serum protein and lactic dehydrogenase (LD) ratios. Like pleural fluid, WBC counts are of
little clinical value, although a count of >1000 WBCs/µL
with a high percentage of neutrophils can indicate bacterial
endocarditis.
Cytologic examination of pericardial exudates for the presence of malignant cells is an important part of the fluid analysis. Cells most frequently encountered are the result of
metastatic lung or breast carcinoma and resemble those found
in pleural fluid. Figure 12–16 shows a metastatic giant
mesothelioma cell that is frequently seen in pleural fluid and
is associated with asbestos contact. Pericardial fluid tumor
marker levels correlate well with cytologic studies.8
Bacterial cultures and Gram stains are performed on
concentrated fluids when endocarditis is suspected. Infections are frequently caused by previous respiratory infections
including Streptococcus, Staphylococcus, adenovirus, and coxsackievirus. Effusions of tubercular origin are increasing as
Figure 12–16 Malignant pericardial effusion showing giant mesothelioma cell with cytoplasmic molding and hyperchromatic nucleoli
(×1000).
a result of AIDS. Therefore, acid-fast stains and chemical
tests for adenosine deaminase are often requested on pericardial effusions.
Peritoneal Fluid
Accumulation of fluid between the peritoneal membranes is
called ascites, and the fluid is commonly referred to as ascitic
fluid rather than peritoneal fluid. In addition to the causes of
transudative effusions discussed previously, hepatic disorders
such as cirrhosis are frequent causes of ascitic transudates.
Bacterial infections (peritonitis)—often as a result of intestinal
perforation or a ruptured appendix—and malignancy are the
most frequent causes of exudative fluids (Table 12–9).
Normal saline is sometimes introduced into the peritoneal
cavity as a lavage to detect abdominal injuries that have not
yet resulted in fluid accumulation. Peritoneal lavage is a sensitive test to detect intra-abdominal bleeding in blunt trauma
cases, and results of the RBC count can be used along with
radiographic procedures to aid in determining the need for
surgery. RBC counts greater than 100,000/mL are indicative of
blunt trauma injuries.
Cell counts and differentials may also be requested on
fluid from peritoneal dialysis to detect infection, and eosinophil
counts to detect allergic reactions to the equipment or introduction of air into the peritoneal cavity.1
Transudates Versus Exudates
Differentiation between ascitic fluid transudates and exudates
is more difficult than for pleural and pericardial effusions. The
serum-ascites albumin gradient (SAAG) is recommended
over the fluid:serum total protein and LD ratios to detect transudates of hepatic origin.9 Fluid and serum albumin levels are
measured concurrently, and the fluid albumin level is then subtracted from the serum albumin level. A difference (gradient)
of 1.1 or greater suggests a transudate effusion of hepatic
origin, and lower gradients are associated with exudative
effusions (see the Example on page 238).
3920_Ch12_229-242 23/01/14 10:35 AM Page 238
238
Part Three | Other Body Fluids
Table 12–9
Significance of Peritoneal Fluid Testing
Test
Appearance
Clear, pale yellow
Turbid
Green
Blood-streaked
Milky
Peritoneal lavage
WBC count
<500 cells/µL
>500 cells/µL
Differential
Carcinoembryonic
antigen
CA 125
Glucose
Amylase
Alkaline phosphatase
Significance
Normal
Microbial infection
Bile, gallbladder, pancreatic
disorders
Trauma, infection, or malignancy
Lymphatic trauma and blockage
>100,000 RBCs/µL indicates
blunt trauma injury
Normal
Bacterial peritonitis, cirrhosis
Bacterial peritonitis,
malignancy
Malignancy of gastrointestinal
origin
Malignancy of ovarian origin
Decreased in tubercular
peritonitis, malignancy
Increased in pancreatitis,
gastrointestinal perforation
Increased in gastrointestinal
perforation
Ruptured or punctured bladder
Laboratory Tests
Normal WBC counts are less than 350 cells/µL, and the count
increases with bacterial peritonitis and cirrhosis. To distinguish
between those two conditions, an absolute neutrophil count
should be performed. An absolute neutrophil count >250 cells/µL
or >50% of the total WBC count indicates infection. Lymphocytes
are the predominant cell in tuberculosis.
Cellular Examination
Examination of ascitic exudates for the presence of malignant
cells is important for detecting tumors of primary and metastatic origin. Malignancies are most frequently of gastrointestinal,
prostate, or ovarian origin. Other cells present in ascitic
fluid include leukocytes, abundant mesothelial cells, and
macrophages, including lipophages (Fig. 12–17). Microorganisms including bacteria, yeast, and Toxoplasma gondii may also
be present (Fig. 12–18). Malignant cells of ovarian, prostatic,
and colonic origin, often containing mucin-filled vacuoles, are
frequently seen (Figs. 12–19 to 12–22). Psammoma bodies
containing concentric striations of collagen-like material
can be seen in benign conditions and are also associated with
ovarian and thyroid malignancies (Fig. 12–23).
Blood urea nitrogen/
creatinine
Gram stain and culture Bacterial peritonitis
Acid-fast stain
Tubercular peritonitis
Adenosine deaminase
Tubercular peritonitis
EXAMPLE
Figure 12–17 Lipophages (macrophages containing fat droplets) in
peritoneal fluid (×500).
Serum albumin of 3.8 mg/dL – fluid albumin of
1.2 mg/dL = gradient of 2.6 = transudate effusion
Serum albumin of 3.8 mg/dL – fluid albumin of
3.0 mg/dL = gradient of 0.8 = exudate effusion
Appearance
Like pleural and pericardial fluids, normal peritoneal fluid is
clear and pale yellow. Exudates are turbid with bacterial or fungal infections. Green or dark-brown color indicates the presence of bile, which can be confirmed using standard chemical
tests for bilirubin. Blood-streaked fluid is seen after trauma and
with tuberculosis, intestinal disorders, and malignancy.
Chylous or pseudochylous material may be present with
trauma or lymphatic vessels blockage.
Figure 12–18 Budding yeast in peritoneal fluid (×400).
3920_Ch12_229-242 23/01/14 10:35 AM Page 239
Chapter 12 | Serous Fluid
Figure 12–19 Ovarian carcinoma showing community borders, nuclear irregularity, and hyperchromatic nucleoli (×500).
Figure 12–20 Ovarian carcinoma cells with large mucin-containing
vacuoles (×500).
Figure 12–21 Adenocarcinoma of the prostate showing cytoplasmic vacuoles, community borders, and hyperchromatic nucleoli
(×500).
Chemical Testing
Chemical examination of ascitic fluid consists primarily of glucose, amylase, and alkaline phosphatase determinations. Glucose is decreased below serum levels in bacterial and tubercular
239
Figure 12–22 Colon carcinoma cells containing mucin vacuoles and
nuclear irregularities (×400).
Figure 12–23 Psammoma bodies exhibiting concentric striations
(×500).
peritonitis and malignancy. Amylase is determined on ascitic
fluid to ascertain cases of pancreatitis, and it may be elevated
in patients with gastrointestinal perforations. An elevated
alkaline phosphatase level is also highly diagnostic of intestinal
perforation.
Measurements of blood urea nitrogen and creatinine in the
fluid are requested when a ruptured bladder or accidental
puncture of the bladder during the paracentesis is of concern.
Bilirubin is measured when leakage of bile into the peritoneum is suspected following trauma or surgery. Bile contains
primarily conjugated bilirubin; therefore, a test for total bilirubin is acceptable.10
Amylase or lipase can be measured to determine whether
the pancreatitis or damage to the pancreas is accounting for the
accumulation of these pancreatic enzymes in the ascitic fluid.10
Microbiology Tests
Gram stains and bacterial cultures for both aerobes and anaerobes are performed when bacterial peritonitis is suspected. Inoculation of fluid into blood culture bottles at the bedside
increases the recovery of anaerobic organisms. Acid-fast stains,
adenosine deaminase, and cultures for tuberculosis may also
be requested.
3920_Ch12_229-242 23/01/14 10:35 AM Page 240
240
Part Three | Other Body Fluids
Serologic Tests
Measurement of the tumor markers CEA and CA 125 is a valuable procedure for identifying the primary source of tumors
producing ascitic exudates. The presence of CA 125 antigen
with a negative CEA suggests the source is from the ovaries,
fallopian tubes, or endometrium.7
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Clinical and Laboratory Standards Institute (CLSI): Body Fluid
Analysis for Cellular Composition, Approved Guideline C49-A,
Wayne, PA, 2006.
2. Jay, SJ: Pleural effusions: Definitive evaluation of the exudate.
Postgrad Med 80(5):180–188, 1986.
3. Light, RW: Clinical practice: Pleural effusion. N Engl J Med
346:1971–1977, 2002.
4. Kjeldsberg, CR, and Knight, JA: Body Fluids: Laboratory
Examination of Amniotic, Cerebrospinal, Seminal, Serous and
Synovial Fluids. A Textbook Atlas. ASCP, Chicago, 1993.
5. Valdez, L, et al: Cholesterol: A useful parameter for distinguishing between pleural exudates and transudates. Chest 99(5):
1097–1102, 1991.
6. Porcel, JM, and Light, RW: Diagnostic approach to pleural fluid
effusion in adults. Am Fam Physician 73:1211–1220, 2006.
7. Colice, GL, et al: Medical and surgical treatment of parapneumonic effusions: An evidence-based guideline. Chest
118:1158–1171, 2000.
8. Porcel, JM, et al: Use of a panel of tumor markers (carcinoembryonic antigen, cancer antigen 125, carbohydrate antigen 15-3
and cytokeratin 19 fragments) in pleural fluid for differential
diagnosis of benign and malignant effusions. Chest 126:
1757–1763, 2004.
9. Runyan, BA, et al: The serum-ascites albumin gradient is
superior to the exudate transudate concept in the differential
diagnosis of ascites. Ann Intern Med 117:215–218, 1992.
10. Clinical and Laboratory Science Institute (CLSI): Analysis of
Body Fluids in Clinical Chemistry, Approved Guideline,
C49-A, Wayne, PA, 2007, CLSI.
Study Questions
1. The primary purpose of serous fluid is to:
A. Remove waste products
B. Lower capillary pressure
C. Lubricate serous membranes
D. Nourish serous membranes
2. The membrane that lines the wall of a cavity is the:
A. Visceral
B. Peritoneal
C. Pleural
D. Parietal
3. During normal production of serous fluid, the slight excess
of fluid is:
A. Absorbed by the lymphatic system
B. Absorbed through the visceral capillaries
C. Stored in the mesothelial cells
D. Metabolized by the mesothelial cells
4. Production of serous fluid is controlled by:
A. Capillary oncotic pressure
B. Capillary hydrostatic pressure
C. Capillary permeability
D. All of the above
5. An increase in the amount of serous fluid is called a/an:
A. Exudate
B. Transudate
C. Effusion
D. Malignancy
6. Pleural fluid is collected by:
A. Pleurocentesis
B. Paracentesis
C. Pericentesis
D. Thoracentesis
7. Place the appropriate letter in front of the following statements describing transudates and exudates.
A. Transudate
B. Exudate
____ Caused by increased hydrostatic pressure
____ Caused by increased capillary permeability
____ Caused by decreased oncotic pressure
____ Caused by congestive heart failure
____ Malignancy related
____ Tuberculosis related
____ Endocarditis related
____ Clear appearance
3920_Ch12_229-242 23/01/14 10:35 AM Page 241
Chapter 12 | Serous Fluid
8. Fluid:serum protein and lactic dehydrogenase ratios are
performed on serous fluids:
A. When malignancy is suspected
B. To classify transudates and exudates
C. To determine the type of serous fluid
D. When a traumatic tap has occurred
9. Which of the following requires the most additional
testing?
A. Transudate
B. Exudate
10. An additional test performed on pleural fluid to classify
the fluid as a transudate or exudate is the:
A. WBC count
B. RBC count
C. Fluid:cholesterol ratio
D. Fluid-to-serum protein gradient
11. A milky-appearing pleural fluid indicates:
A. Thoracic duct leakage
B. Chronic inflammation
C. Microbial infection
D. Both A and B
12. Which of the following best represents a hemothorax?
A. Blood HCT: 42 Fluid HCT: 15
B. Blood HCT: 42 Fluid HCT: 10
C. Blood HCT: 30 Fluid HCT: 10
D. Blood HCT: 30 Fluid HCT: 20
13. All of the following are normal cells seen in pleural fluid
except:
A. Mesothelial cells
B. Neutrophils
C. Lymphocytes
D. Mesothelioma cells
14. A differential observation of pleural fluid associated with
tuberculosis is:
A. Increased neutrophils
B. Decreased lymphocytes
C. Decreased mesothelial cells
D. Increased mesothelial cells
15. All of the following are characteristics of malignant cells
except:
A. Cytoplasmic molding
B. Absence of nucleoli
C. Mucin-containing vacuoles
D. Increased nucleus:cytoplasm ratio
241
16. A pleural fluid pH of 6.0 indicates:
A. Esophageal rupture
B. Mesothelioma
C. Malignancy
D. Rheumatoid effusion
17. Plasma cells seen in pleural fluid indicate:
A. Bacterial endocarditis
B. Primary malignancy
C. Metastatic lung malignancy
D. Tuberculosis infection
18. A significant cell found in pericardial or pleural fluid that
should be referred to cytology is a:
A. Reactive lymphocyte
B. Mesothelioma cell
C. Monocyte
D. Mesothelial cell
19. Another name for a peritoneal effusion is:
A. Peritonitis
B. Lavage
C. Ascites
D. Cirrhosis
20. A test performed primarily on peritoneal lavage fluid is
a/an:
A. WBC count
B. RBC count
C. Absolute neutrophil count
D. Amylase
21. The recommended test for determining whether peritoneal fluid is a transudate or an exudate is the:
A. Fluid:serum albumin ratio
B. Serum ascites albumin gradient
C. Fluid:serum lactic dehydrogenase ratio
D. Absolute neutrophil count
22. Given the following results, classify this peritoneal fluid:
serum albumin, 2.2 g/dL; serum protein, 6.0 g/dL; fluid
albumin, 1.6 g/dL.
A. Transudate
B. Exudate
23. Differentiation between bacterial peritonitis and cirrhosis
is done by performing a/an:
A. WBC count
B. Differential
C. Absolute neutrophil count
D. Absolute lymphocyte count
3920_Ch12_229-242 23/01/14 10:35 AM Page 242
242
Part Three | Other Body Fluids
24. Detection of the CA 125 tumor marker in peritoneal fluid
indicates:
A. Colon cancer
B. Ovarian cancer
C. Gastric malignancy
D. Prostate cancer
26. Cultures of peritoneal fluid are incubated:
A. Aerobically
B. Anaerobically
C. At 37°C and 42°C
D. Both A and B
25. Chemical tests primarily performed on peritoneal fluid include all of the following except:
A. Lactose dehydrogenase
B. Glucose
C. Alkaline phosphatase
D. Amylase
Case Studies and Clinical Situations
1. Fluid from a patient with congestive heart failure is collected by thoracentesis and sent to the laboratory for
testing. It appears clear and pale yellow and has a WBC
count of 450/mL, fluid:serum protein ratio of 0.35, and
fluid:serum LD ratio of 0.46.
a. What type of fluid was collected?
b. Based on the laboratory results, would this fluid be
considered a transudate or an exudate? Why?
c. List two other tests that could be performed to aid in
classifying this fluid.
2. A cloudy pleural fluid has a glucose level of 30 mg/dL
(serum glucose level is 100 mg/dL) and a pH of 6.8.
a. What condition do these results indicate?
b. What additional treatment might the patient receive,
based on these results?
3. The following results were obtained on a peritoneal fluid:
serum albumin, 2.8 g/dL; fluid albumin, 1.2 g/dL.
a. Calculate the SAAG.
b. Is this a transudate or an exudate? Why?
c. What is the most probable cause of the effusion?
4. Paracentesis is performed on a patient with ascites. The
fluid appears turbid and has an elevated WBC count.
Additional tests ordered include an absolute granulocyte
count, amylase, creatinine, CEA, and CA 125.
a. What is the purpose for the absolute granulocyte
count? If it is less than 250 cells/mL, what condition
is indicated?
b. If the amylase level is elevated, what is its significance?
State an additional test that might be ordered.
c. Explain the significance of an elevated creatinine level.
d. What is the purpose of the CEA and CA 125 tests?
5. Describe a situation in which paracentesis might be
performed on a patient who does not have ascites. If the
RBC count is 300,000/mL, what does this indicate?
6. Microscopic examination of an ascitic fluid shows many
cells with nuclear and cytoplasmic irregularities containing psammoma bodies. The CEA test result is normal.
What additional test would be helpful?
3920_Ch13_243-254 23/01/14 10:36 AM Page 243
CHAPTER
13
Amniotic Fluid
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
13-1 State the functions of amniotic fluid.
13-2 Describe the formation and composition of amniotic
fluid.
13-3 Differentiate maternal urine from amniotic fluid.
13-4 State indications for performing an amniocentesis.
13-5 Describe the specimen-handling and processing
procedures for testing amniotic fluid for bilirubin,
fetal lung maturity (FLM), and cytogenetic analysis.
13-6 Discuss the principle of the spectrophotometric analysis for evaluation of hemolytic disease of the newborn.
13-7 Interpret a Liley graph.
13-8 Describe the analysis of amniotic fluid for the
detection of neural tube disorders.
13-9 Explain the physiologic significance of the lecithinsphingomyelin (L/S) ratio.
13-10 State the relationship of phosphatidyl glycerol to
FLM.
13-11 Define lamellar bodies and describe their significance
to FLM.
13-12 Discuss the principle of and sources of error for the
L/S ratio, Amniostat-FLM, lamellar body count, and
Foam Stability Index for FLM.
KEY TERMS
Amniocentesis
Meconium
Amnion
Hemolytic disease of the newborn
(HDN)
Amniotic fluid
Lamellar bodies
Polyhydramnios
Cytogenetic analysis
Lecithin-sphingomyelin ratio
(L/S ratio)
Respiratory distress syndrome (RDS)
Fetal lung maturity (FLM)
Oligohydramnios
Surfactants
3920_Ch13_243-254 23/01/14 10:36 AM Page 244
244
Part Three | Other Body Fluids
Although the testing of amniotic fluid is frequently associated
with cytogenetic analysis, the clinical laboratory also performs several significant tests on amniotic fluid. Because amniotic fluid is a product of fetal metabolism, the constituents
that are present in the fluid provide information about the
metabolic processes taking place during—as well as the
progress of—fetal maturation. When conditions that adversely
affect the fetus arise, the danger to the fetus must be measured
against the ability of the fetus to survive an early delivery. The
tests covered in this chapter are used to determine the extent
of fetal distress and fetal maturity (Table 13–1).
Physiology
Amniotic fluid is present in the amnion, a membranous sac
that surrounds the fetus (Fig. 13–1). The amnion is metabolically active and is involved in the exchanges of water and
chemicals between the fluid, the fetus, and the maternal circulation; and produces peptides, growth factors, and cytokines.
The primary functions of the amniotic fluid are to provide a
protective cushion for the fetus, allow fetal movement, stabilize
the temperature to protect the fetus from extreme temperature
changes, and permit proper lung development.
Volume
Amniotic fluid volume is regulated by a balance between the
production of fetal urine and lung fluid and the absorption
Tests for Fetal Well-Being and Maturity
Test
Reference
Values at
Term7
Bilirubin scan
⌬ A450 >.025
Alphafetoprotein
Lecithinsphingomyelin
ratio
Amniostatfetal lung
maturity
Foam Stability
Index
Optical density
650 nm
Lamellar body
count
<2.0 MoM
≥ 2.0
Significance
Hemolytic
disease of the
newborn
Neural tube
disorders
Fetal lung
maturity
≥ 47
Fetal lung
maturity/phosphatidyl glycerol
Fetal lung maturity
≥ 0.150
Fetal lung maturity
≥ 32,000/mL
Fetal lung maturity
Positive
Chorion
Amniotic cavity
Umbilical cord
Amnion
Figure 13–1 Fetus in amniotic sac.
Function
Table 13–1
Placenta
from fetal swallowing and intramembranous flow. Intramembranous flow is the absorption of amniotic fluid water and
solutes into the fetal vascular system.1 The amount of amniotic
fluid increases in quantity throughout pregnancy, reaching a
peak of approximately 800 to 1200 mL during the third
trimester, and then gradually decreases prior to delivery. An
amniotic fluid volume greater than 1200 mL is called polyhydramnios, whereas amniotic fluid volume less than 800 mL is
termed oligohydramnios. In either case, some analytes will be
falsely low or falsely high.2 During the first trimester, the
approximately 35 mL of amniotic fluid is derived primarily
from the maternal circulation. During the latter third to half of
pregnancy, the fetus secretes a volume of lung liquid necessary
to expand the lungs with growth. During each episode of fetal
respiratory movement, secreted lung liquid enters the amniotic
fluid, bathing the lungs and washing pulmonary and alveolar
contents such as lecithin, sphingomyelin, and phosphatidyl
glycerol into the amniotic fluid surrounding the fetus.2 These
lung surfactants serve as an index of fetal lung maturity.1 After
the first trimester, fetal urine is the major contributor to the
amniotic fluid volume. At the time that fetal urine production
occurs, fetal swallowing of the amniotic fluid begins and
regulates the increase in fluid from the fetal urine. The fetus
swallows amniotic fluid, which is absorbed through the gastrointestinal tract and reexcreted by the kidneys from the blood
into fetal urine and back into amniotic fluid.2
Failure of the fetus to begin swallowing results in excessive
accumulation of amniotic fluid (polyhydramnios) and is an
indication of fetal distress, often associated with neural tube disorders. Polyhydramnios may be secondarily associated with fetal
structural anomalies, cardiac arrhythmias, congenital infections,
or chromosomal abnormalities.1 Increased fetal swallowing, urinary tract deformities, and membrane leakage are possible causes
of decreased amniotic fluid (oligohydramnios). Oligohydramnios
may be associated with congenital malformations, premature rupture of amniotic membranes, and umbilical cord compression,
resulting in decelerated heart rate and fetal death.1
Chemical Composition
The placenta is the ultimate source of amniotic fluid water and
solutes. Amniotic fluid has a composition similar to that of the
3920_Ch13_243-254 23/01/14 10:36 AM Page 245
Chapter 13 | Amniotic Fluid
maternal plasma and contains a small amount of sloughed fetal
cells from the skin, digestive system, and urinary tract. These
cells provide the basis for cytogenetic analysis. The fluid also
contains biochemical substances that are produced by the
fetus, such as bilirubin, lipids, enzymes, electrolytes, urea, creatinine, uric acid, proteins, and hormones that can be tested
to determine the health or maturity of the fetus. Neural tube
defects allow fetal cerebrospinal fluid to enter the amniotic
fluid directly. Alpha-fetoprotein and acetylcholinesterase are
two biochemical markers tested for these defects.2
A portion of the fluid arises from the fetal respiratory tract,
fetal urine, the amniotic membrane, and the umbilical cord.
As would be expected, the chemical composition of the amniotic fluid changes when fetal urine production begins. The concentrations of creatinine, urea, and uric acid increase, whereas
glucose and protein concentrations decrease. Concentrations
of electrolytes, enzymes, hormones, and metabolic end products also vary but are of little clinical significance. Measurement
of amniotic fluid creatinine has been used to determine fetal
age. Prior to 36 weeks’ gestation, the amniotic fluid creatinine
level ranges between 1.5 and 2.0 mg/dL. It then rises above
2.0 mg/dL, thereby providing a means of determining fetal age
greater than 36 weeks.3
Differentiating Maternal Urine From
Amniotic Fluid
Differentiation between amniotic fluid and maternal urine may
be necessary to determine possible premature membrane rupture or accidental puncture of the maternal bladder during
specimen collection. Chemical analysis of creatinine, urea, glucose, and protein aids in the differentiation. Levels of creatinine
and urea are much lower in amniotic fluid than in urine. Creatinine does not exceed 3.5 mg/dL and urea does not exceed
30 mg/dL in amniotic fluid, whereas values as high as
10 mg/dL for creatinine and 300 mg/dL for urea may be found
in urine.4 Measurement of glucose and protein by a reagent
strip is a less reliable indicator, because glucose and protein
are not uncommon urine constituents during pregnancy. However, under normal circumstances, the presence of glucose,
protein, or both is associated more closely with amniotic fluid.
The fern test also can differentiate amniotic fluid from
urine and other body fluids. It is a test used to evaluate premature rupture of the membranes. In the fern test, a vaginal
fluid specimen is spread on a glass slide and allowed to completely air dry at room temperature; then it is observed microscopically. The presence of “fern-like” crystals due to the
protein and sodium chloride content is a positive screen for
amniotic fluid.5
Specimen Collection
Indications for Amniocentesis
Amniocentesis is recommended for neural tube defects
when screening blood tests such as the maternal serum alphafetoprotein test are abnormal or to detect genetic disorders or
245
to evaluate the health of the fetus. Fetal body measurements
taken with ultrasonography accurately estimate the gestational
age of the fetus and provide an assessment of the size and
growth of the fetus throughout pregnancy to diagnose and
manage intrauterine growth retardation. Finding an abnormality on the ultrasound could indicate potential fetal development problems and indicate the need for an amniocentesis and
laboratory measurements of fetal lung maturity.
Fetal epithelial cells in amniotic fluid indicate the genetic
material of the fetus and the biochemical substances that the
fetus has produced. These cells can be separated from the fluid,
cultured, and examined for chromosome abnormalities by
karyotyping, fluorescence in situ hybridization (FISH), fluorescent mapping spectral karyotyping (SKY), and DNA testing.
Biochemical substances produced by the fetus can be analyzed
by thin-layer chromatography to evaluate the health of the
fetus. (Table 13–2)
In general, amniocentesis is a safe procedure, particularly
when performed after the 14th week of gestation. Fluid for
chromosome analysis is usually collected at approximately
16 weeks’ gestation and tests for intrauterine growth retardation are performed near the end of the second trimester,
whereas tests for fetal distress and maturity are performed later
in the third trimester.2
Table 13–2
Indications for Performing Amniocentesis
Amniocentesis may be indicated at 15 to 18 weeks’
gestation for the following conditions to determine
early treatment or intervention:
• Mother’s age of 35 or older at delivery
• Family history of chromosome abnormalities, such as
trisomy 21 (Down syndrome)
• Parents carry an abnormal chromosome rearrangement
• Earlier pregnancy or child with birth defect
• Parent is a carrier of a metabolic disorder
• Family history of genetic diseases such a sickle cell disease, Tay-Sachs disease, hemophilia, muscular dystrophy,
sickle cell anemia, Huntington chorea, and cystic fibrosis
• Elevated maternal serum alpha-fetoprotein
• Abnormal triple marker screening test
• Previous child with a neural tube disorder such as spina
bifida, or ventral wall defects (gastroschisis)
• Three or more miscarriages
Amniocentesis is indicated later in the pregnancy
(20 to 42 weeks) to evaluate:
• Fetal lung maturity
• Fetal distress
• HDN caused by Rh blood type incompatibility
• Infection
3920_Ch13_243-254 23/01/14 10:36 AM Page 246
246
Part Three | Other Body Fluids
Collection
Amniotic fluid is obtained by needle aspiration into the amniotic sac, a procedure called amniocentesis. The procedure
most frequently performed is a transabdominal amniocentesis. Using continuous ultrasound for guidance, the physician
locates the fetus and placenta to safely perform the procedure.
A thin, hollow needle is inserted through the mother’s abdomen into the mother’s uterus and into the amniotic sac to
aspirate the amniotic fluid. Vaginal amniocentesis may also
be performed; however, this method carries a greater risk of
infection.
A maximum of 30 mL of amniotic fluid is collected in sterile syringes. The first 2 or 3 mL collected can be contaminated
by maternal blood, tissue fluid, and cells and are discarded.
Specimens should be transferred to sterile plastic containers
and taken immediately to the laboratory. Fluid for bilirubin
analysis in cases of hemolytic disease of the newborn (HDN)
must be protected from light at all times.
Specimen Handling and
Processing
Handling and processing of amniotic fluid vary with the tests
requested and with the methodology used by the laboratory
performing the test. However, in all circumstances, special handling procedures should be performed immediately and the
specimen delivered promptly to the laboratory. Fluid for fetal
lung maturity (FLM) tests should be placed in ice for delivery
to the laboratory and kept refrigerated. Specimens for bilirubin
testing must be immediately protected from light. This can be
accomplished by placing the specimens in amber-colored
tubes, wrapping the collection tube in foil, or by use of a black
plastic cover for the specimen container. Specimens for cytogenetic studies or microbial studies must be processed aseptically and maintained at room temperature or body temperature
(37°C incubation) prior to analysis to prolong the life of the
cells needed for analysis.
All fluid for chemical testing should be separated from
cellular elements and debris as soon as possible to prevent
distortion of chemical constituents by cellular metabolism or
disintegration. This can be performed using centrifugation or
filtration. The time and speed of centrifugation also depends
on the test and lab protocol.
Color and Appearance
Normal amniotic fluid is colorless and may exhibit slight to
moderate turbidity from cellular debris, particularly in later
stages of fetal development. Blood-streaked fluid may be present as the result of a traumatic tap, abdominal trauma, or intraamniotic hemorrhage. The source of the blood (maternal or
fetal) can be determined using the Kleihauer-Betke test for fetal
hemoglobin and is important for further case management.
The presence of bilirubin gives the fluid a yellow color and
is indicative of red blood cell destruction resulting from HDN.
Meconium, which is usually defined as a newborn’s first bowel
movement, is formed in the intestine from fetal intestinal
secretions and swallowed amniotic fluid. It is a dark green,
mucus-like material. It may be present in the amniotic fluid as
a result of fetal distress. Fetal aspiration of meconium during
fetal swallowing is a concern when increased amounts are present in the fluid. A very dark red-brown fluid is associated with
fetal death (Table 13–3).
Tests for Fetal Distress
Hemolytic Disease of the Newborn
The oldest routinely performed laboratory test on amniotic
fluid evaluates the severity of the fetal anemia produced by
HDN. The incidence of this disease has been decreasing rapidly
since the development of methods to prevent anti-Rh antibody
production in postpartum mothers. However, antibodies
against other red cell antigens are also capable of producing
HDN, and immunization of Rh-negative mothers may not be
effective or even performed in all cases. Initial exposure to foreign red cell antigens occurs during gestation, delivery of the
placenta, or a previous pregnancy when fetal red blood cells
enter into the maternal circulation and stimulate the mother
to produce antibodies to the antigen. When these antibodies
present in the maternal circulation cross the placenta into the
fetal circulation and bind to the antigen on the fetal cells, the
cells are destroyed. The destruction of fetal red blood cells
results in the appearance of the red blood cell degradation
product, unconjugated bilirubin, in the amniotic fluid. By
measuring the amount of bilirubin in the fluid, the extent of
hemolysis taking place may be determined, and the danger this
anemia presents to the fetus may be assessed (Fig. 13–2).
Amniotic fluid bilirubin is measured by spectrophotometric
analysis using serial dilutions. As illustrated in Figure 13–3, the
optical density (OD) of the fluid is measured in intervals between 365 nm and 550 nm and the readings plotted on semilogarithmic graph paper. In normal fluid, the OD is highest at
365 nm and decreases linearly to 550 nm, illustrated by a
straight line. When bilirubin is present, a rise in OD is seen at
450 nm because this is the wavelength of maximum bilirubin
absorption. The difference between the OD of the theoretic
baseline and the OD at 450 nm represents the amniotic fluid
Table 13–3
Amniotic Fluid Color
Color
Significance
Colorless
Blood-streaked
Normal
Traumatic tap, abdominal trauma,
intra-amniotic hemorrhage
Hemolytic disease of the newborn
(bilirubin)
Meconium
Fetal death
Yellow
Dark green
Dark red-brown
3920_Ch13_243-254 23/01/14 10:36 AM Page 247
Chapter 13 | Amniotic Fluid
Baby 1
Figure 13–2 Rh antibodies crossing the placenta.
0.6
Absorbance
0.5
Rh+
Rh+ fetus
Fetal blood enters
maternal circulation
via placenta
IgG antibodies
cross placenta
to destroy
fetal Rh+ RBCs
IgG antibodies remain
in mother’s circulation
0.1
410
450
500
Rh+
Rh+ fetus
No
rm
sca al
n
365
Baby 2
2nd Pregnancy
0.4
0.2
Rh
antibody
1st Pregnancy
Oxyhemoglobin Bilirubin
peak at 410 peak at 450
0.3
Rh–
Rh–
Rh–
247
550
Wavelength (nm)
Figure 13–3 Spectrophotometric bilirubin scan showing bilirubin
and oxyhemoglobin peaks.
bilirubin concentration. This difference in OD, referred to as
the absorbance difference at 450 nm (⌬ A450), is then plotted
on a Liley graph to determine the severity of the hemolytic
disease (Fig. 13–4).6
Notice that the Liley graph plots the ⌬ A450 against gestational age and is divided into three zones that represent the
extent of hemolytic severity. Values falling in zone I indicate
no more than a mildly affected fetus; those in zone II indicate
moderate hemolysis and require careful monitoring anticipating an early delivery or exchange transfusion upon delivery,
whereas a value in zone III indicates severe hemolysis and suggests a severely affected fetus. Intervention through induction
of labor or intrauterine exchange transfusion must be considered when a ⌬ A450 is plotted in zone III.
As mentioned, specimens must be protected from light at
all times. Markedly decreased values will be obtained with as
little as 30 minutes of exposure to light. Contamination of the
fluid by cells, hemoglobin, meconium, or other debris will interfere with the spectrophotometric analysis. Specimens should
be immediately centrifuged to remove particulate interference.
Specimens contaminated with meconium will cause falsely low
⌬ A450 values and are not acceptable for spectrophotometric
analysis. Specimens that are contaminated with blood are generally unacceptable because maximum absorbance of oxyhemoglobin occurs at 410 nm and can interfere with the bilirubin
absorption peak (see Fig. 13–3). This interference can be removed by extraction with chloroform if necessary.7 A control
may be prepared by diluting commercial chemistry control sera
1 to 10 with normal saline and treating it in the same manner
as the patient specimen. Bilirubin and protein levels approximate those in amniotic fluid and can be varied by using low
or high control sera.8
Neural Tube Defects
Neural tube defects (NTD) are one of the most common birth
defects in the United States. It can be detected by maternal
serum alpha-fetoprotein (MSAFP) blood test, high-resolution
ultrasound, and amniocentesis. Increased levels of alpha-fetoprotein (AFP) in both the maternal circulation and the amniotic
fluid can be indicative of fetal neural tube defects, such as anencephaly and spina bifida. AFP is the major protein produced by
the fetal liver during early gestation (prior to 18 weeks). It is
found in the maternal serum due to the combined fetal-maternal
circulations and in the amniotic fluid from diffusion and excretion of fetal urine. Increased levels are found in the maternal
3920_Ch13_243-254 23/01/14 10:36 AM Page 248
248
Part Three | Other Body Fluids
1.00
0.90
0.80
0.70
0.60
0.50
∆ O.D. Change in optical density
0.40
0.30
Severely affected fetus
intervention required
Zone III
0.20
Zone II
0.10
0.09
0.08
0.07
Moderately affected fetus
requiring close monitoring
0.06
0.05
0.04
0.03
Zone I
0.02
Nonaffected or mildly
affected fetus
0.01
20
22
24
26
28
30
32
34
Gestational age in weeks
serum and amniotic fluid when the skin fails to close over the
neural tissue, as occurs in anencephaly and spina bifida.
Measurement of amniotic fluid AFP levels is indicated
when maternal serum levels are elevated or a family history
of previous neural tube defects exists. The possibility of a multiple pregnancy also must be investigated when serum levels
are elevated. Normal values are based on the week of gestational age, as the fetus produces maximal AFP between 12 and
15 weeks’ gestation, after which levels in amniotic fluid begin
to decline. Both serum and amniotic fluid AFP levels are
reported in terms of multiples of the median (MoM). The
median is the laboratory’s reference level for a given week of
gestation. A value two times the median value is considered
abnormal (greater than 2 MoM) for both maternal serum and
amniotic fluid. Elevated amniotic fluid AFP levels are followed
by measurement of amniotic acetylcholinesterase (AChE).
The test is more specific for neural tube disorders than AFP,
provided it is not performed on a bloody specimen, because
blood contains AChE.4
Tests for Fetal Maturity
Fetal distress, whether caused by HDN or other conditions,
forces the obstetrician to consider a preterm delivery. At this
point, fetal maturity must be assessed.
Fetal Lung Maturity
Respiratory distress syndrome (RDS) is the most frequent
complication of early delivery and is the seventh most common
cause of morbidity and mortality in the premature infant.9
This disease is caused by an insufficiency of lung surfactant
36
38
40
Figure 13–4 Example of a Liley graph.
production and structural immaturity of the fetal lungs. Surfactant normally appears in mature lungs and allows the alveoli
(air sacs of the lung) to remain open throughout the normal
cycle of inhalation and exhalation. Surfactant keeps the alveoli
from collapsing by decreasing surface tension and allows them
to inflate with air more easily. If the surfactant concentrations
are too low, the alveoli will collapse, causing RDS. The incidence of RDS decreases with increasing gestational age and
lung maturity.9 Therefore, laboratory tests must be performed
to determine the maturity of the fetal lungs. The amount of
surfactant in fetal lungs can be estimated by measuring the
amount of surfactants in amniotic fluid.9 Several laboratory
tests are available to measure FLM.
Lecithin-Sphingomyelin Ratio
The reference method to which tests of FLM are compared is
the lecithin-sphingomyelin (L/S) ratio. Lecithin is the primary component of the surfactants (phospholipids, neutral
lipids, and proteins) that make up the alveolar lining and
account for alveolar stability.
Lecithin is produced at a relatively low and constant rate
until the 35th week of gestation, at which time a noticeable
increase in its production occurs, resulting in the stabilization
of the fetal lung alveoli. Sphingomyelin is a lipid that is produced at a constant rate after about 26 weeks’ gestation; therefore, it can serve as a control on which to base the rise in
lecithin. Both lecithin and sphingomyelin appear in the amniotic fluid in amounts proportional to their concentrations
in the fetus.10 Prior to 35 weeks’ gestation, the L/S ratio is usually less than 1.6 because large amounts of lecithin are not
being produced at this time. After 35 weeks’ gestation, the
3920_Ch13_243-254 23/01/14 10:37 AM Page 249
Chapter 13 | Amniotic Fluid
lecithin concentration increases while the sphingomyelin concentration remains constant. The L/S ratio will rise to 2.0 or
higher as the lecithin production increases to prevent alveolar
collapse. Therefore, when the L/S ratio reaches 2.0, a preterm
delivery is usually considered to be a relatively safe procedure.
Falsely elevated results are encountered in fluid contaminated
with blood or meconium because both these substances contain lecithin and sphingomyelin.
Quantitative measurement of lecithin and sphingomyelin
is performed using thin-layer chromatography (TLC). Because
the procedure is labor intensive and subject to high coefficients
of variation, many laboratories have replaced the L/S ratio with
the quantitative phosphatidyl glycerol immunoassays and
lamellar body density procedures.11
Phosphatidyl Glycerol
The presence of another lung surface lipid, phosphatidyl glycerol (PG), is also essential for adequate lung maturity and can
be detected after 35 weeks’ gestation. The production of PG
normally parallels that of lecithin, but its production is delayed
in cases of maternal diabetes. In this circumstance, respiratory
distress occurs in the presence of an L/S ratio of 2.0. Therefore,
a thin-layer chromatography lung profile must include lecithin,
sphingomyelin, and PG to provide an accurate measurement
of FLM.12
Development of an immunologic agglutination test for PG
has provided a more rapid and easy to perform method for assessment of fetal maturity that does not require a laboratory to
be equipped to perform thin-layer chromatography. The
Aminostat-FLM (Irving Scientific, Santa Ana, CA) uses antisera
containing polyclonal anti-PG antibodies that are specific for
PG-containing lamellar bodies in the amniotic fluid. The size
of the agglutinates is read macroscopically and the results are
reported as either negative, indicating pulmonary immaturity,
or low positive or high positive, indicating pulmonary maturity.
The test is not affected by specimen contamination with blood
and meconium.13 Studies have shown good correlation with
thin-layer chromatography but with a slightly higher incidence
of false-negative results that may need to be followed up with
further testing.14,15
gradient of ethanol/fluid ratios ranging from 0.42 mL to 0.55 mL
in 0.01-mL increments, which can be used to provide a semiquantitative measure of the amount of surfactant present. A value
of 47 or higher indicates FLM. The Foam Stability Index has
shown good correlation with the L/S ratio and tests for phosphatidyl glycerol. The test cannot be used with contaminated amniotic fluid because blood and meconium also reduce surface
tension, yielding a falsely mature index result.
Lamellar Bodies
Surfactant is composed of approximately 90% phospholipid
and 10% protein and is packaged into layered storage granules
called lamellar bodies.9,18 Lamellar bodies are densely packed
layers of phospholipids that represent a storage form of pulmonary surfactant. They are secreted by the type II pneumocytes of the fetal lung at about 24 weeks of gestation and are
absorbed into the alveolar spaces to provide surfactant. They
enter the amniotic fluid at about 26 weeks of gestation and
increase in concentration from 50,000 to 200,000 per microliter by the end of the third trimester. As the fetal lung matures, increased lamellar body production is reflected by an
increase in amniotic fluid phospholipids and the L/S ratio.19
Therefore, the number of lamellar bodies present in the amniotic fluid correlates with the amount of phospholipid present in the fetal lungs.
The presence of lamellar bodies increases the OD of
the amniotic fluid. Specimens are centrifuged at 2000 g for
10 minutes and examined using a wavelength of 650 nm,
which rules out interference from hemoglobin but not other
PROCEDURE 13-1
Foam Shake Test
1.
2.
3.
4.
Mix equal parts of amniotic fluid with 95% ethanol.
Vigorously shake for 15 seconds.
Allow to sit undisturbed for 15 minutes.
Observe for the presence of a continuous line of
bubbles around the outside edge.
Foam Stability Index
Until the development of biochemical techniques to measure
the individual lung-surface lipid concentrations, a mechanical
screening test, called the “foam” or “shake” test, was used to
determine their presence. Because it can be performed at the
bedside or in the laboratory, the test is still in use. Amniotic
fluid is mixed with 95% ethanol, shaken for 15 seconds, and
allowed to sit undisturbed for 15 minutes. At the end of this
time, the surface of the fluid is observed for the presence of a
continuous line of bubbles around the outside edge. The presence of bubbles indicates that a sufficient amount of phospholipid is available to reduce the surface tension of the fluid even
in the presence of alcohol, an antifoaming agent.
A modification of the foam test uses 0.5 mL of amniotic
fluid added to increasing amounts of 95% ethanol, providing a
249
PROCEDURE 13-2
Foam Stability Index
1. Add 0.5 mL of amniotic fluid to tubes containing
increasing amounts of 95% ethanol ranging from
0.42 to 0.55 mL in 0.01-mL increments.
2. Vigorously shake for 15 seconds.
3. Allow to sit undisturbed for 15 minutes.
4. Observe for the presence of a continuous line of
bubbles around the outside edge.
5. Values ≥ 47 indicate fetal lung maturity.
3920_Ch13_243-254 23/01/14 10:37 AM Page 250
250
Part Three | Other Body Fluids
HISTORICAL NOTE
Microviscosity: Fluorescence
Polarization Assay
The fluorescence polarization assay is no longer performed
because the manufacturer (Abbott Laboratories, Abbott
Park, IL) discontinued the instrument and reagents in
2011. It was the most widely used test in evaluating FLM
and was considered an excellent screening tool for FLM
because the results correlated well with an L/S ratio of
2.0.16 The fluorescence polarization assay for FLM measured the surfactant to albumin (S/A) ratio to measure FLM.
The test was based on the principle that phospholipids decrease the microviscosity of the amniotic fluid. This
change in microviscosity was measured using the principle
of fluorescence polarization using the TDX/TDxFLx FLM
II Assay System (Abbott Laboratories, Abbott Park, IL).
The assay measured the polarization of a fluorescent dye
that combined with both surfactants and albumin in the
amniotic fluid. The fluorescent dye bound to surfactant
had a longer fluorescence lifetime and a low polarization,
whereas dye bound to albumin had a decreased fluorescence lifetime and a high polarization. The recorded
changes in polarization produced a surfactant/albumin
ratio expressed in milligrams surfactant to grams albumin
that was compared with a fetal lung maturity II assay
calibration standard curve using calibrators of known surfactant/albumin content. A surfactant/albumin ratio of
55 mg/g indicated FLM, whereas values between 40 mg/g
and 54 mg/g were indeterminate and ratios less than or
equal to 39 mg/g indicated immature lungs.17
The test required 1.0 mL of amniotic fluid, and specimens contaminated with blood, meconium, suspected maternal urine, and visibly icteric sample could not be used.
contaminants, such as meconium. An OD of 0.150 has been
shown to correlate well with an L/S ratio of greater than or
equal to 2.0 and the presence of phosphatidyl glycerol.20
volume of amniotic fluid required, and (6) excellent clinical
performance.18
Amniotic fluid specimens containing whole blood, meconium, and mucus should not be used. Blood initially raises
the LBC because of the presence of platelets and then can
lower the LBC as lamellar bodies are trapped in the fibrin
strands.18 Meconium and mucus cause a false increase in the
LBC and should not be used for testing. Specimens may be
stored at 2°C to 8°C but never frozen. A consensus protocol
for performing LBC has been published by CLSI and is described in Procedure 13–3. Results are reported in units of
lamellar bodies per microliter and should be accompanied by
the laboratory’s established values for maturity and the instrument that was used. A consensus protocol for noncentrifuged
samples considers LBCs greater than 50,000/␮L an indication
of FLM and values below 15,000/␮L as immature. Results in
between these two values are considered indeterminate and
further testing using alternate methods is recommended.21
PROCEDURE 13-3
Lamellar Body Count18
1. Mix the amniotic fluid sample by inverting the
capped sample container five times.
2. Transfer the fluid to a clear test tube to allow for
visual inspection.
3. Visually inspect the specimen. Fluids containing
obvious mucus, whole blood, or meconium should
not be processed for an LBC.
4. Cap the tube and mix the sample by gentle inversion or
by placing the test tube on a tube rocker for 2 minutes.
5. Flush the platelet channel; analyze the instrument’s
diluents buffer until a background count deemed
acceptable by the laboratory is obtained in two
consecutive analyses.
6. Process the specimen through the cell counter and
record the platelet channel as the LBC.
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
Lamellar Body Count
Lamellar body diameter is similar to that of small platelets
ranging in size from 1.7 to 7.3 fL, or 1 to 5␮m; therefore,
lamellar body counts (LBCs) can be obtained using the
platelet channel of automated hematology analyzers using either optical or impedance methods for counting.18 Some automated cell counters use both impedance and optical
methods for counting. Because the various hematology analyzers count lamellar bodies differently and require different
specimen preparation, cutoff values for FLM vary, making it
necessary to establish analyzer-specific LBC clinical decision
limits.18 The advantages of lamellar body counting include:
(1) rapid turnaround time, (2) low reagent cost, (3) wide
availability, (4) low degree of technical difficulty, (5) low
References
1. Ross, MG, Brace, RA, and the NIH Workshop Participants,
National Institute of Child Health and Development Conference
summary: Amniotic fluid biology—basic and clinical aspects.
J Maternal-Fetal Med 10:2–19, 2001.
2. Clinical and Laboratory Standards Institute (CLSI): Analysis of
Body Fluids in Clinical Chemistry: approved guideline, CLSI
Document C49-A, Wayne, PA, 2007, CLSI.
3. Weiss, RR, et al: Amniotic fluid uric acid and creatinine as measures of fetal maturity. Obstet Gynecol 44(2):208–214, 1974.
3920_Ch13_243-254 23/01/14 10:37 AM Page 251
Chapter 13 | Amniotic Fluid
4. Wenk, RE, and Rosenbaum, JM: Examination of amniotic fluid.
In Henry, JB (ed): Clinical Diagnosis and Management by
Laboratory Methods. WB Saunders, Philadelphia, 1996.
5. Heron, HJ: The use of the Fern test to differentiate amniotic
fluid from urine. Triangle Jul:20:60–62, 1963.
6. Liley, AW: Liquor amnii analysis in the management of the
pregnancy complicated by Rhesus sensitization. Am J Obstet
Gynecol 82:1359, 1961.
7. Spinnato, JA, et al: Amniotic bilirubin and fetal hemolytic
disease. Am J Obstet Gynecol 165(4):1030–1035, 1991.
8. McDonald, OL, and Watts, MT: Use of commercially prepared
control sera as quality control materials for spectrophotometric
bilirubin determinations in amniotic fluid. Am J Clin Pathol
84(4):513–517, 1985.
9. Grenache, D: Fetal lung maturity testing: what labs need to
know now. Medical Lab Observer (MLO), February 2012.
10. Gluck, L, et al: Diagnosis of the respiratory distress syndrome
by amniocentesis. Am J Obstet Gynecol 109(3):440–445, 1971.
11. Dubin, SB: Assessment of FLM: Practice parameter. Am J Clin
Pathol 110:723–732, 1998.
12. Kulovich, MV, Hallman, MB, and Gluck, L: The lung profile:
Normal pregnancy. Am J Obstet Gynecol 135:57–60, 1979.
13. Eisenbrey, AB, et al: Phosphatidyl glycerol in amniotic fluid:
Comparison of an “ultrasensitive” immunologic assay with TLC
and enzymatic assay. Am J Clin Pathol 91(3):293–297, 1989.
251
14. Chapman, JF: Current methods for evaluating FLM. Lab
Med 17(10):597–602, 1986.
15. Saad, SA, et al: The reliability and clinical use of a rapid
phosphatidyl glycerol assay in normal and diabetic pregnancies. Am J Obstet Gynecol 157(6):1516–1520, 1987.
16. Winn-McMillan, T, and Karon, BS: Comparison of the
TDx-FLM II and lecithin to sphingomyelin ratio assays in
predicting fetal lung maturity. Am J Obstet Gynecol
193,778–782, 2005.
17. TDx/TDxFLx Fetal Lung Maturity II (FLM II) package insert.
Reference 7A76. Abbott Laboratories, Diagnostics Division,
Abbott Park, IL, April 2003.
18. Clinical and Laboratory Standards Institute. Assessment of fetal
lung maturity by the lamellar body count; approved guideline,
CLSI document C58-A. Wayne, PA, CLSI, 2011.
19. Khazardoost, S, et al: Amniotic fluid lamellar body count and
its sensitivity and specificity in evaluating of fetal lung maturity.
J Obstet Gynaecol 25(3):257–259, 2005.
20. Sbarra, AJ, et al: Correlation of amniotic fluid optical density at
650 nm and lecithin/sphingomyelin ratios. Obstet Gynecol
48:613, 1976.
21. Lu Ji, Gronowski, AM, Eby, C,: Lamellar Body Counts Performed
on Automated Hematology Analyzers to Assess Fetal Lung Maturity. LabMedicine 39(7): 419–423, 2008.
Study Questions
1. Which of the following is not a function of amniotic fluid?
A. Allows movement of the fetus
B. Allows carbon dioxide and oxygen exchange
C. Protects fetus from extreme temperature changes
D. Acts as a protective cushion for the fetus
2. What is the primary cause of the normal increase in amniotic fluid as a pregnancy progresses?
A. Fetal cell metabolism
B. Fetal swallowing
C. Fetal urine
D. Transfer of water across the placenta
3. Which of the following is not a reason for decreased
amounts of amniotic fluid?
A. Fetal failure to begin swallowing
B. Increased fetal swallowing
C. Membrane leakage
D. Urinary tract defects
4. Why might a creatinine level be requested on an amniotic
fluid?
A. Detect oligohydramnios
5. Amniotic fluid specimens are placed in amber-colored tubes
prior to sending them to the laboratory to prevent the
destruction of:
A. Alpha-fetoprotein
B. Bilirubin
C. Cells for cytogenetics
D. Lecithin
6. How are specimens for FLM testing delivered to and stored
in the laboratory?
A. Delivered on ice and refrigerated
B. Immediately centrifuged
C. Kept at room temperature
D. Delivered in a vacuum tube
7. Why are amniotic specimens for cytogenetic analysis incubated at 37°C prior to analysis?
A. To detect the presence of meconium
B. To differentiate amniotic fluid from urine
C. To prevent photo-oxidation of bilirubin to biliverdin
D. To prolong fetal cell viability and integrity
8. Match the following colors in amniotic fluid with their
significance.
B. Detect polyhydramnios
___ A. Colorless
1. Fetal death
C. Differentiate amniotic fluid from maternal urine
___ B. Dark green
2. Normal
___ C. Red-brown
3. Presence of bilirubin
___ D. Yellow
4. Presence of meconium
D. Evaluate lung maturity
3920_Ch13_243-254 23/01/14 10:37 AM Page 252
252
Part Three | Other Body Fluids
9. A significant rise in the OD of amniotic fluid at 450 nm
indicates the presence of which analyte?
A. Bilirubin
B. Lecithin
C. Oxyhemoglobin
D. Sphingomyelin
15. When performing an L/S ratio by thin-layer chromatography,
a mature fetal lung will show:
A. Sphingomyelin twice as concentrated as lecithin
B. No sphingomyelin
C. Lecithin twice as concentrated as sphingomyelin
D. Equal concentrations of lecithin and sphingomyelin
10. Plotting the amniotic fluid OD on a Liley graph represents
the severity of hemolytic disease of the newborn. A value
that is plotted in zone II indicates what condition of the
fetus?
A. No hemolysis
B. Mildly affected fetus
C. Moderately affected fetus that requires close monitoring
D. Severely affected fetus that requires intervention
16. True or False: Phosphatidyl glycerol is present with an L/S
ratio of 1.1.
11. The presence of a fetal neural tube disorder may be
detected by:
A. Increased amniotic fluid bilirubin
B. Increased maternal serum alpha-fetoprotein
C. Decreased amniotic fluid phosphatidyl glycerol
D. Decreased maternal serum acetylcholinesterase
12. True or False: An AFP MoM value greater than two times
the median value is considered an indication of a neural
tube disorder.
13. When severe HDN is present, which of the following tests
on the amniotic fluid would the physician not order to
determine whether the fetal lungs are mature enough to
withstand a premature delivery?
A. AFP levels
B. Foam stability index
C. Lecithin/sphingomyelin ratio
D. Phosphatidyl glycerol detection
17. A rapid immunologic test for FLM that does not require
performance of thin-layer chromatography is:
A. AFP levels
B. Amniotic acetylcholinesterase
C. Aminostat-FLM
D. Bilirubin scan
18. Does the failure to produce bubbles in the Foam Stability
Index indicate increased or decreased lecithin?
A. Increased
B. Decreased
19. The presence of phosphatidyl glycerol in amniotic fluid
fetal lung maturity tests must be confirmed when:
A. Hemolytic disease of the newborn is present
B. The mother has maternal diabetes
C. Amniotic fluid is contaminated by hemoglobin
D. Neural tube disorder is suspected
20. A lamellar body count of 50,000 correlates with:
A. Absent phosphatidyl glycerol and L/S ratio of 1.0
B. L/S ratio of 1.5 and absent phosphatidyl glycerol
C. OD at 650 nm of 1.010 and an L/S ratio of 1.1
D. OD at 650 nm of 0.150 and an L/S ratio of 2.0
14. True or False: Prior to 35 weeks’ gestation, the normal L/S
ratio is less than 1.6.
Case Studies and Clinical Situations
1. Amniocentesis is performed on a woman believed to be
in approximately the 31st week of gestation. This is the
second pregnancy for this Rh-negative woman with diabetes. Spectrophotometric analysis of the fluid shows a
∆ A450 of 0.3.
a. Based on the Liley graph, should the physician
consider inducing labor?
b. What else must the physician consider prior to inducing
labor?
The physician decides to induce labor based on a
positive Aminostat-FLM.
c. What information did this test provide for the physician?
d. Why did the physician prefer an Aminostat-FLM to an
L/S ratio in this situation?
2. Amniocentesis is performed following a maternal serum
AFP level of 2.2 MoM at 15 weeks’ gestation.
a. What fetal condition is suspected?
b. If the amniotic fluid AFP is 2.5 MoM, what additional
test could be performed?
c. In what situation would this additional test not be
performed?
3920_Ch13_243-254 23/01/14 10:37 AM Page 253
Chapter 13 | Amniotic Fluid
3. How might a dark green amniotic fluid affect the results
of the following tests?
a. Foam Stability Index
b. L/S ratio
c. Aminostat-FLM
d. OD650
4. How might a blood-streaked amniotic fluid affect the
results of the following tests?
a. L/S ratio
b. AChE
c. Bilirubin analysis
d. Aminostat-FLM
253
5. Amniocentesis is performed on a woman whose last two
pregnancies resulted in stillbirths due to hemolytic disease
of the newborn. A screening test performed at the hospital
is positive for bilirubin, and the specimen is sent to a
reference laboratory for a bilirubin scan. Physicians are
concerned when the report comes back negative. What
factors would be considered in evaluating this result.
a. Correct specimen was sent
b. Specimen was refrigerated
c. Specimen was exposed to light
d. Specimen reached the reference lab within 30 mins
3920_Ch13_243-254 23/01/14 10:37 AM Page 254
3920_Ch14_255-268 23/01/14 10:38 AM Page 255
CHAPTER
14
Fecal Analysis
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
14-1 Describe the normal composition and formation of
feces.
14-10 State the significance of increased neutrophils in a
stool specimen.
14-2 Differentiate between secretory and osmotic diarrhea
using fecal electrolytes, fecal osmolality, and stool pH.
14-11 Describe a positive microscopic examination for
muscle fibers.
14-3 List three causes of secretory and osmotic diarrhea.
14-12 Name the fecal fats stained by Sudan III, and give
the conditions under which they will stain.
14-4 Describe the mechanism of altered motility and at
least three conditions that can cause it.
14-5 List three causes of steatorrhea.
14-6 Differentiate malabsorption from maldigestion syndromes and name a test that distinguishes the two
conditions.
14-7 Instruct patients in the collection of random and
quantitative stool specimens.
14-8 State a pathogenic and a nonpathogenic cause for
stools that are red, black, and pale yellow.
14-9 State the significance of bulky, ribbon-like, and
mucus-containing stools.
14-13 Describe and interpret the microscopic results that
are seen when a specimen from a patient with steatorrhea is stained with Sudan III.
14-14 Discuss the collection procedure for a quantitative
fecal fat and methods for analysis.
14-15 Explain the methods used to detect fecal occult blood.
14-16 Instruct a patient in the collection of specimens for
occult blood, including an explanation of dietary restrictions for the guaiac test.
14-17 Briefly describe a chemical screening test performed
on feces for each of the following: fetal hemoglobin,
pancreatic insufficiency, and carbohydrate intolerance.
KEY TERMS
Acholic stools
Malabsorption
Osmotic diarrhea
Constipation
Maldigestion
Secretory diarrhea
Diarrhea
Occult blood
Steatorrhea
3920_Ch14_255-268 23/01/14 10:38 AM Page 256
256
Part Three | Other Body Fluids
In the minds of most laboratory personnel, fecal specimen analysis
fits into the category of a “necessary evil.” However, as an end product of body metabolism, feces do provide valuable diagnostic
information. Routine fecal examination includes macroscopic,
microscopic, and chemical analyses for the early detection of gastrointestinal (GI) bleeding, liver and biliary duct disorders,
maldigestion/malabsorption syndromes, pancreatic diseases,
inflammation, and causes of diarrhea and steatorrhea. Of equal
diagnostic value is the detection and identification of pathogenic
bacteria, viruses, and parasites; however, these procedures are best
covered in a microbiology textbook and are not discussed here.
Physiology
The normal fecal specimen contains bacteria, cellulose, undigested
foodstuffs, GI secretions, bile pigments, cells from the intestinal
walls, electrolytes, and water. Approximately 100 to 200 g of feces
is excreted in a 24-hour period. Many species of bacteria make up
the normal flora of the intestines. Bacterial metabolism produces
the strong odor associated with feces and intestinal gas (flatus).
Carbohydrates, especially oligosaccharides, that are resistant to
digestion pass through the upper intestine unchanged but are
metabolized by bacteria in the lower intestine, producing large
amounts of flatus. Excessive gas production also occurs in lactoseintolerant people when the intestinal bacteria metabolize the
lactose from consumed milk or lactose-containing substances.
Although digestion of ingested proteins, carbohydrates, and
fats takes place throughout the alimentary tract, the small intestine is the primary site for the final breakdown and reabsorption of these compounds. Digestive enzymes secreted into the
small intestine by the pancreas include trypsin, chymotrypsin,
amino peptidase, and lipase. Bile salts provided by the liver aid
in the digestion of fats. A deficiency in any of these substances
creates an inability to digest and, therefore, to reabsorb certain
foods. Excess undigested or unreabsorbed materials then appear
in the feces, and the patient exhibits symptoms of maldigestion
and malabsorption. As shown in Figure 14–1, approximately
9000 mL of ingested fluid, saliva, gastric, liver, pancreatic, and
intestinal secretions enter the digestive tract each day. Under normal conditions, only between 500 to 1500 mL of this fluid
reaches the large intestine, and only about 150 mL is excreted in
the feces. Water and electrolytes are readily absorbed in both the
small and large intestines, resulting in a fecal electrolyte content
that is similar to that of plasma.
Food and drink
2000 mL
Saliva
1500 mL
Gastric
secretions
1500 mL
Bile from liver
1000 mL
Intestinal
secretions
2000 mL
(water and
electrolytes)
Feces
150 mL
Pancreas
1000 mL
Mucous
secretions
200 mL
Colon
(up to 3000 mL of
water reabsorbed)
Figure 14–1 Fluid regulation in the gastrointestinal
tract.
3920_Ch14_255-268 23/01/14 10:38 AM Page 257
Chapter 14 | Fecal Analysis
The large intestine is capable of absorbing approximately 3000 mL of water. When the amount of water reaching the large intestine exceeds this amount, it is excreted
with the solid fecal material, producing diarrhea. Constipation, on the other hand, provides time for additional water
to be reabsorbed from the fecal material, producing small,
hard stools.
Diarrhea and Steatorrhea
Diarrhea
Diarrhea is defined as an increase in daily stool weight above
200 g, increased liquidity of stools, and frequency of more than
three times per day. Diarrhea classification can be based on four
factors: illness duration, mechanism, severity, and stool characteristics. Diarrhea lasting less than 4 weeks is defined as
acute, and diarrhea persisting for more than 4 weeks is termed
chronic diarrhea.
The major mechanisms of diarrhea are secretory, osmotic,
and intestinal hypermotility. The laboratory tests used to
differentiate these mechanisms are fecal electrolytes (fecal
sodium, fecal potassium), fecal osmolality, and stool pH. The
normal total fecal osmolarity is close to the serum osmolality
(290 mOsm/kg), normal fecal sodium is 30 mmol/L, and fecal
potassium is 75 mmol/L. The fecal sodium and fecal potassium
results are used to calculate the fecal osmotic gap. The fecal osmotic gap is calculated as follows:
Osmotic gap = 290 – [2 (fecal sodium + fecal potassium)]
The osmotic gap in all forms of osmotic diarrhea is
greater than 50 mOsm/kg and less than 50 mOsm/kg in
secretory diarrhea. Electrolytes are increased in secretory
diarrhea and negligible in osmotic diarrhea. A fecal fluid pH
of less than 5.6 indicates a malabsorption of sugars, causing
an osmotic diarrhea.
disorders (hyperthyroidism, Zollinger-Ellison syndrome, VIPoma),
neoplasms, and collagen vascular disease.
Osmotic Diarrhea
Osmotic diarrhea is caused by poor absorption that exerts osmotic pressure across the intestinal mucosa. Incomplete breakdown or reabsorption of food presents increased fecal material to
the large intestine, resulting in water and electrolyte retention in
the large intestine (osmotic diarrhea), which in turn results in excessive watery stool. Maldigestion (impaired food digestion) and
malabsorption (impaired nutrient absorption by the intestine)
contribute to osmotic diarrhea. The presence of unabsorbable
solute increases the stool osmolality and the concentration of electrolytes is lower, resulting in an increased osmotic gap. Causes of
osmotic diarrhea include disaccharidase deficiency (lactose intolerance), malabsorption (celiac sprue), poorly absorbed sugars (lactose, sorbitol, mannitol), laxatives, magnesium-containing
antacids, amebiasis, and antibiotic administration. Laboratory testing of feces is frequently performed to aid in determining the cause
of diarrhea (Table 14–1). Table 14–2 differentiates the features of
osmotic diarrhea and secretory diarrhea.
Table 14–1
Common Fecal Tests for Diarrhea
Secretory
Osmotic
Stool cultures
Ova and parasite
examinations
Rotavirus immunoassay
Fecal leukocytes
Microscopic fecal fats
Muscle fiber detection
Qualitative fecal fats
Trypsin screening
Microscopic fecal fats
Muscle fiber detection
Quantitative fecal fats
Clinitest
D-xylose tolerance test
Lactose tolerance test
Fecal electrolytes
Stool pH
Fecal osmolality
Secretory Diarrhea
Secretory diarrhea is caused by increased secretion of water.
Bacterial, viral, and protozoan infections produce increased secretion of water and electrolytes, which override the reabsorptive ability of the large intestine, leading to secretory diarrhea.
Enterotoxin-producing organisms such as Escherichia coli,
Clostridium, Vibrio cholerae, Salmonella, Shigella, Staphylococcus,
Campylobacter, protozoa, and parasites such as Cryptosporidium
can stimulate these water and electrolyte secretions. Other
causes of secretory diarrhea are drugs, stimulant laxatives,
hormones, inflammatory bowel disease (Crohn disease, ulcerative colitis, lymphocytic colitis, diverticulitis), endocrine
TECHNICAL TIP Process specimens for osmolality testing
immediately. Specimens that are stored for hours may
have a markedly increased osmolality due to the increased
degradation of carbohydrates.
257
Table 14–2
Differential Features for Diarrhea
Laboratory
Test
Osmotic
Diarrhea
Secretory
Diarrhea
Osmotic gap
Stool Na
Stool output
in 24 hours
pH
Reducing
substances
>50 Osm/kg
<60 mmol/L
<200 g
<50 Osm/kg
>90 mmol/L
>200 g
<5.3
Positive
>5.6
Negative
3920_Ch14_255-268 23/01/14 10:38 AM Page 258
258
Part Three | Other Body Fluids
Altered Motility
Altered motility describes conditions of enhanced motility (hypermotility) or slow motility (constipation). Both can be seen
in irritable bowel syndrome (IBS), a functional disorder in
which the nerves and muscles of the bowel are extra sensitive,
causing cramping, bloating, flatus, diarrhea, and constipation.
IBS can be triggered by food, chemicals, emotional stress, and
exercise.
Intestinal hypermotility is the excessive movement of intestinal contents through the GI tract that can cause diarrhea
because normal absorption of intestinal contents and nutrients
cannot occur. It can be caused by enteritis, the use of parasympathetic drugs, or with complications of malabsorption. Rapid
gastric emptying (RGE) dumping syndrome describes hypermotility of the stomach and the shortened gastric emptying
half-time, which causes the small intestine to fill too quickly
with undigested food from the stomach. It is the hallmark of
early dumping syndrome (EDS).1 Healthy people have a gastric emptying half-time range of 35 to 100 minutes, which
varies with age and gender. A gastric emptying time of less than
35 minutes is considered RGE.1 RGE can be caused by disturbances in the gastric reservoir or in the transporting function.
Alterations in the motor functions of the stomach result in
accumulation of large amounts of osmotically active solids and
liquids to be transported into the small intestine. Normal gastric emptying is controlled by fundic tone, duodenal feedback,
and GI hormones. These are altered after gastric surgery,
resulting in clinically significant dumping syndrome in approximately 10% of patients.2
RGE can be divided into early dumping and late dumping
depending upon how soon after a meal the symptoms occur.
EDS symptoms begin 10 to 30 minutes following meal ingestion.2 Symptoms include nausea, vomiting, bloating, cramping,
diarrhea, dizziness, and fatigue. Late dumping occurs 2 to
3 hours after a meal and is characterized by weakness, sweating, and dizziness.1 Hypoglycemia is often a complication of
dumping syndrome. The main causes of dumping syndrome
include gastrectomy, gastric bypass surgery, post vagotomy
status, Zollinger-Ellison syndrome, duodenal ulcer disease, and
diabetes mellitus.1
Steatorrhea
Detection of steatorrhea (fecal fat) is useful in diagnosing pancreatic insufficiency and small-bowel disorders that cause malabsorption. Absence of bile salts that assist pancreatic lipase in
the breakdown and subsequent reabsorption of dietary fat (primarily triglycerides) produces an increase in stool fat (steatorrhea) that exceeds 6 g per day. Likewise, pancreatic disorders,
including cystic fibrosis, chronic pancreatitis, and carcinoma,
that decrease the production of pancreatic enzymes, are also
associated with steatorrhea. Steatorrhea may be present in both
maldigestion and malabsorption conditions and can be distinguished by the D-xylose test. D-Xylose is a sugar that does not
need to be digested but does need to be absorbed to be present
in the urine. If urine D-xylose is low, the resulting steatorrhea
indicates a malabsorption condition. Malabsorption causes
include bacterial overgrowth, intestinal resection, celiac disease, tropical sprue, lymphoma, Whipple disease, Giardia
lamblia infestation, Crohn disease, and intestinal ischemia. A
normal D-xylose test indicates pancreatitis.
Specimen Collection
Collection of a fecal specimen, frequently called a stool specimen, is not an easy task for patients. Detailed instructions and
appropriate containers depending on the type of test and
amount of feces required should be provided. For certain tests,
dietary restrictions are required before fecal specimen collection.
Patients should be instructed to collect the specimen in a
clean container, such as a bedpan or disposable container, and
transfer the specimen to the laboratory container. Patients
should understand that the specimen must not be contaminated with urine or toilet water, which may contain chemical
disinfectants or deodorizers that can interfere with chemical
testing. Containers that contain preservatives for ova and parasites must not be used to collect specimens for other tests.
Random specimens suitable for qualitative testing for
blood and microscopic examination for leukocytes, muscle
fibers, and fecal fats are usually collected in plastic or glass containers with screw-tops similar to those used for urine specimens. Material collected on a physician’s glove and samples
applied to filter paper in occult blood testing kits are also
received.
For quantitative testing, such as for fecal fats, timed specimens are required. Because of the variability of bowel habits and
the transit time required for food to pass through the digestive
tract, the most representative sample is a 3-day collection. These
specimens are frequently collected in large containers to accommodate the specimen quantity and facilitate emulsification before testing. Care must be taken when opening any fecal
specimen to slowly release gas that has accumulated within the
container. Patients must be cautioned not to contaminate the
outside of the container.
Macroscopic Screening
The first indication of GI disturbances can often be changes in
the brown color and formed consistency of the normal stool.
Of course, the appearance of abnormal fecal color may also be
caused by ingestion of highly pigmented foods and medications, so a differentiation must be made between this and a
possible pathologic cause.
Color
The brown color of the feces results from intestinal oxidation
of stercobilinogen to urobilin. As discussed in Chapter 5, conjugated bilirubin formed in the degradation of hemoglobin
passes through the bile duct to the small intestine, where intestinal bacteria convert it to urobilinogen and stercobilinogen.
Therefore, stools that appear pale (acholic stools) may signify
a blockage of the bile duct. Pale stools are also associated with
diagnostic procedures that use barium sulfate.
3920_Ch14_255-268 23/01/14 10:38 AM Page 259
Chapter 14 | Fecal Analysis
A primary concern is the presence of blood in a stool
specimen. Depending on the area of the intestinal tract from
which bleeding occurs, the color can range from bright red
to dark red to black. Blood that originates from the esophagus, stomach, or duodenum takes approximately 3 days to
appear in the stool; during this time, degradation of hemoglobin produces the characteristic black, tarry stool. Likewise,
blood from the lower GI tract requires less time to appear and
retains its original red color. Both black and red stools should
be chemically tested for the presence of blood, because
ingestion of iron, charcoal, or bismuth often produces a black
stool, and some medications and some foods, including beets,
produce a red stool.
Green stools may be observed in patients taking oral antibiotics, because of the oxidation of fecal bilirubin to
biliverdin. Ingestion of increased amounts of green vegetables
or food coloring also produces green stools.
Appearance
Besides variations in color, additional abnormalities may be observed during macroscopic examination. Table 14–3 lists common abnormalities seen in macroscopic evaluation. Examples
include the watery consistency present in diarrhea; small, hard
stools seen with constipation; and slender, ribbon-like stools,
which suggest obstruction of the normal passage of material
through the intestine.
Table 14–3
Macroscopic Stool Characteristics12,26
Color/
Appearance
Black
Red
Pale yellow,
white, gray
Green
Bulky/frothy
Ribbon-like
Mucus- or
blood-streaked
mucus
Possible Cause
Upper GI bleeding
Iron therapy
Charcoal
Bismuth (antacids)
Lower GI bleeding
Beets and food coloring
Rifampin
Bile-duct obstruction
Barium sulfate
Biliverdin/oral antibiotics
Green vegetables
Bile-duct obstruction
Pancreatic disorders
Intestinal constriction
Colitis
Dysentery
Malignancy
Constipation
259
Pale stools associated with biliary obstruction and steatorrhea appear bulky and frothy and frequently have a foul
odor. Stools may appear greasy and may float.
The presence of mucus-coated stools indicates intestinal
inflammation or irritation. Mucus-coated stools may be caused
by pathologic colitis, Crohn disease, colon tumors, or excessive
straining during elimination. Blood-streaked mucus suggests
damage to the intestinal walls, possibly caused by bacterial
or amebic dysentery or malignancy. The presence of mucus
should be reported.
Microscopic Examination
of Feces
Microscopic screening of fecal smears is performed to detect
the presence of leukocytes associated with microbial diarrhea
and undigested muscle fibers and fats associated with
steatorrhea.
Fecal Leukocytes
Leukocytes, primarily neutrophils, are seen in the feces in conditions that affect the intestinal mucosa, such as ulcerative
colitis and bacterial dysentery. Microscopic screening is performed as a preliminary test to determine whether diarrhea is
being caused by invasive bacterial pathogens including Salmonella, Shigella, Campylobacter, Yersinia, and enteroinvasive
E. coli. Bacteria that cause diarrhea by toxin production, such
as Staphylococcus aureus and Vibrio spp., viruses, and parasites
usually do not cause the appearance of fecal leukocytes. Therefore, the presence or absence of fecal neutrophils can provide
the physician with diagnostic information before receiving the
culture report.
Specimens can be examined as wet preparations stained
with methylene blue or as dried smears stained with Wright’s
or Gram stain. Methylene blue staining is the faster procedure
but may be more difficult to interpret. Dried preparations
stained with either Wright's or Gram stains provide permanent
slides for evaluation. An additional advantage of the Gram stain
is the observation of gram-positive and gram-negative bacteria,
which could aid in the initial treatment.3 All slide preparations
must be performed on fresh specimens. In an examination of
preparations under high power, as few as three neutrophils per
high-power field can be indicative of an invasive condition.4
Using oil immersion, the finding of any neutrophils has approximately 70% sensitivity for the presence of invasive
bacteria.5
A lactoferrin latex agglutination test is available for detecting fecal leukocytes and remains sensitive in refrigerated and
frozen specimens. The presence of lactoferrin, a component of
granulocyte secondary granules, indicates an invasive bacterial
pathogen.6
Muscle Fibers
Microscopic examination of the feces for undigested striated
muscle fibers can be helpful in diagnosing and monitoring
3920_Ch14_255-268 23/01/14 10:38 AM Page 260
260
Part Three | Other Body Fluids
PROCEDURE 14-1
Methylene Blue Stain for Fecal Leukocytes
1.
2.
3.
4.
5.
Place mucus or a drop of liquid stool on a slide.
Add two drops of Löffler methylene blue.
Mix with a wooden applicator stick.
Allow to stand for 2 to 3 minutes.
Examine for neutrophils under high power.
patients with pancreatic insufficiency, such as in cases of cystic fibrosis. It is frequently ordered in conjunction with microscopic examinations for fecal fats. Increased amounts of striated
fibers may also be seen in biliary obstruction and gastrocolic
fistulas.
Slides for muscle fiber detection are prepared by emulsifying a small amount of stool in 10% alcoholic eosin, which
enhances the muscle fiber striations. The entire slide is examined for exactly 5 minutes, and the number of red-stained
fibers with well-preserved striations is counted (Fig. 14–2).
Care must be taken to correctly classify the fibers observed.
Undigested fibers have visible striations running both vertically
and horizontally. Partially digested fibers exhibit striations in
only one direction, and digested fibers have no visible striations. Only undigested fibers are counted, and the presence of
more than 10 is reported as increased (Fig. 14–3).
To produce a representative sample, patients should be instructed to include red meat in their diet before collecting the
specimen. Specimens should be examined within 24 hours of
collection.
Qualitative Fecal Fats
Specimens from suspected cases of steatorrhea can be screened
microscopically for the presence of excess fecal fat (steatorrhea).
The procedure can also be used to monitor patients undergoing
treatment for malabsorption disorders.7 In general, correlation
Figure 14–2 Meat fibers present in fecal emulsion specimen using
brightfield microscopy examination (×400).
Figure 14–3 Note striations on meat fiber present in a fecal emulsion
specimen (×1000).
PROCEDURE 14-2
Muscle Fibers
1. Emulsify a small amount of stool in two drops of
10% eosin in alcohol.
2. Apply cover slip and let stand 3 minutes.
3. Examine under high power for 5 minutes.
4. Count the number of undigested fibers.
between the qualitative and quantitative fecal fat procedures is
good; however, additional unstained phospholipids and cholesterol esters are measured by the quantitative procedure.8,9 Lipids
included in the microscopic examination of feces are neutral fats
(triglycerides), fatty acid salts (soaps), fatty acids, and cholesterol.
Their presence can be observed microscopically by staining with
the dyes Sudan III, Sudan IV, or oil red O; Sudan III is the most
routinely used. The staining procedure consists of two parts: the
neutral fat stain and the split fat stain.
Neutral fats are readily stained by Sudan III and appear as
large orange-red droplets, often located near the edge of the
cover slip.10 Observation of more than 60 droplets/high-power
field can indicate steatorrhea; however, the split fat stain representing total fat content can provide a better indication.11 Breakdown of neutral fats by bacterial lipase and spontaneous
hydrolysis of neutral fats may lower the neutral fat count, which
precludes comparison of the two slide tests to determine
whether maldigestion or malabsorption is causing steatorrhea.
Soaps and fatty acids do not stain directly with Sudan III, so
a second slide must be examined after the specimen has been
mixed with acetic acid and heated. Examining this slide reveals
stained droplets that represent not only the free fatty acids but
also the fatty acids produced by hydrolysis of the soaps and the
neutral fats (Fig. 14–4). In an examination of this split fat slide,
both the number and size of the fat droplets must be considered.
3920_Ch14_255-268 23/01/14 10:39 AM Page 261
Chapter 14 | Fecal Analysis
261
Chemical Testing of Feces
Occult Blood
Figure 14–4 Several orange-red neutral fat globules present in a fecal
suspension stained with Sudan III (×400).
PROCEDURE 14-3
Neutral Fat Stain
1. Homogenize one part stool with two parts water.
2. Mix emulsified stool with one drop of 95% ethyl alcohol on slide.
3. Add two drops of saturated Sudan III in 95%
ethanol.
4. Mix and apply cover slip.
5. Examine under high power.
6. Count orange droplets per high-power field.
By far the most frequently performed fecal analysis is the detection of occult blood (hidden blood). As discussed previously, bleeding in the upper GI tract may produce a black, tarry
stool, and bleeding in the lower GI tract may result in an
overtly bloody stool. However, because any bleeding in excess
of 2.5 mL/150 g of stool is considered pathologically significant, and no visible signs of bleeding may be present with this
amount of blood, fecal occult blood testing (FOBT) is necessary. Annual testing for occult blood has a high positive predictive value for detecting colorectal cancer in the early stages
and is recommended by the American Cancer Society, particularly for people older than age 50.13 Methods for detecting fecal
occult blood include the guaiac, immunochemical, and fluorometric porphyrin quantification tests. Immunochemical tests
and fecal porphyrin quantification tests are more sensitive and
specific methods than the guaiac-based fecal occult blood tests.
Guaiac-Based Fecal Occult Blood Tests
The most frequently used screening test for fecal blood is the
guaiac-based test for occult blood (gFOBT) based on detecting
the pseudoperoxidase activity of hemoglobin. This is the same
principle as the reagent strip test for urinary blood, but uses a
different indicator chromogen. The reaction uses the pseudoperoxidase activity of hemoglobin reacting with hydrogen peroxide
to oxidize a colorless compound to a colored compound.
Pseudoperoxidase
Normal specimens may contain as many as 100 small droplets,
less than 4 µm in diameter, per high-power field. The same number of droplets measuring 1 to 8 µm is considered slightly increased, and 100 droplets measuring 6 to 75 µm is increased and
commonly seen in steatorrhea.12 An increased amount of total fat
on the second slide with normal fat content on the first slide is
an indication of malabsorption, whereas maldigestion is indicated
by increased neutral fat on the first slide.
Cholesterol is stained by Sudan III after heating and as
the specimen cools forms crystals that can be identified
microscopically.
PROCEDURE 14-4
Split Fat Stain
1.
2.
3.
4.
5.
6.
Mix emulsified stool with one drop of 36% acetic acid.
Add two drops of saturated Sudan III.
Mix and apply cover slip.
Heat gently almost to boiling.
Examine under high power.
Count and measure the orange droplets per highpower field.
Hemoglobin + H2O2 + guaiac
(colorless)
oxidized guaiac + H2O
(Blue color)
Several different indicator chromogens have been used to
detect occult blood. All react in the same chemical manner but
vary in their sensitivity. Contrary to most chemical testing, the
least sensitive reagent, guaiac, is preferred for routine testing.
Considering that a normal stool can contain up to 2.5 mL of
blood, a less sensitive chemical reactant is understandably
more desirable. In addition, pseudoperoxidase activity is present from hemoglobin and myoglobin in ingested meat and fish,
certain vegetables and fruits, and some intestinal bacteria.
Therefore, to prevent false-positive reactions, test sensitivity
must be decreased, which can be accomplished by varying the
amount and purity of the guaiac reagent used in the test.
Many commercial testing kits are available for occult blood
testing with guaiac reagent. The kits contain guaiac-impregnated
filter paper enclosed in a cardboard slide, to which the fecal
specimen and hydrogen peroxide are added. Two or three filter
paper areas are provided for application of material taken from
different areas of the stool, and positive and negative controls
are also included. Obtaining samples from the center of the
stool avoids false-positive reactions from external contamination. The patient is asked to collect samples from stool specimens collected on 3 consecutive days. The sample is placed
on the front side of the slide with an applicator stick and the
3920_Ch14_255-268 23/01/14 10:39 AM Page 262
262
Part Three | Other Body Fluids
slide is closed. Adding hydrogen peroxide to the back of the
filter paper slide that contains stool produces a blue color with
guaiac reagent when pseudoperoxidase activity is present.
Packaging of the guaiac-impregnated filter paper in individually sealed containers has facilitated colorectal cancer
screening by allowing patients at home to place a specimen
on a filter paper slide and bring or mail it to the laboratory
for testing. To prevent false-positive reactions, specimens
mailed to the laboratory should not be rehydrated before
adding the hydrogen peroxide unless specifically instructed
by the kit manufacturer. Specimens applied to the paper in
the laboratory should be allowed to dry before testing. The
specimens should be tested within 6 days of collection. Two
samples from three different stools should be tested before a
negative result is confirmed. To prevent the presence of dietary pseudoperoxidases in the stool, patients should be instructed to avoid eating red meats, horseradish, melons, raw
broccoli, cauliflower, radishes, and turnips for 3 days before
specimen collection. Aspirin and NSAIDs other than acetaminophen should not be taken for 7 days before specimen
collection to prevent possible GI irritation. Vitamin C and
iron supplements containing vitamin C should be avoided for
3 days before collections, because ascorbic acid is a strong
reducing agent that interferes with the peroxidase reaction,
causing a false-negative result.14
Immunochemical Fecal Occult Blood Test
The immunochemical fecal occult blood test (iFOBT) is specific for the globin portion of human hemoglobin and uses
polyclonal anti-human hemoglobin antibodies. Because this
method is specific for human blood in feces, it does not require dietary or drug restrictions. It is more sensitive to lower
GI bleeding that could be an indicator of colon cancer or
other GI disease and can be used for patients who are taking
aspirin and other anti-inflammatory medications. The iFOBT
tests do not detect bleeding from other sources, such as a
bleeding ulcer, thus decreasing the chance for false-positive
reactions. Hemoglobin from upper GI bleeding is degraded
by bacterial and digestive enzymes before reaching the large
intestine and is immunochemically nonreactive. In contrast,
there is little hemoglobin degradation in lower GI bleeding,
so the blood is immunochemically active.15 Collection kits
are similar to those used for guaiac testing, such as the Hemoccult ICT test (Beckman Coulter Inc., Fullerton, CA), and
can be provided to patients for home collection. Depending
on the method used, the results may be read visually or by
an automated photometric instrument.
Porphyrin-Based Fecal Occult Blood Test
HemoQuant (SmithKline Diagnostics, Sunnyvale, CA) offers a
porphyrin-based FOBT fluorometric test for hemoglobin based
on the conversion of heme to fluorescent porphyrins. The test
measures both intact hemoglobin and the hemoglobin that has
been converted to porphyrins. As hemoglobin progresses through
the intestinal tract, bacterial actions degrade it to porphyrin that
the gFOBT cannot detect, thereby making the HemoQuant test
more sensitive to upper GI bleeding. False-negative results from
upper GI bleeding can be seen with the gFOBT. Additionally, the
porphyrin-based test is not affected by the presence of reducing
or oxidizing substances or the water content of the fecal specimen. False-positive results can occur with the porphyrin-based
test when non-human sources of blood (red meat) are present;
therefore, patients should be instructed to avoid red meat for
3 days before the test.
Quantitative Fecal Fat Testing
Quantitative fecal fat analysis is used as a confirmatory test for
steatorrhea. As discussed, quantitative fecal analysis requires
the collection of at least a 3-day specimen. The patient must
maintain a regulated intake of fat (100 g/d) before and during
the collection period. The specimen is collected in a large, preweighed container. Before analysis, the specimen is weighed
and homogenized. Refrigerating the specimen prevents any
bacterial degradation. The method routinely used for fecal fat
measurement is the Van de Kamer titration, although gravimetric, near-infrared reflectance spectroscopy, and nuclear magnetic resonance spectroscopy methods are available.10 In the
titration method, fecal lipids are converted to fatty acids and
titrated to a neutral endpoint with sodium hydroxide. Approximately 80% of the total fat content is measured by titration,
whereas the gravimetric method measures all fecal fat. A drawback of the titration/gravimetric method is that it is time
consuming and uses corrosive and flammable solvents. A rapid
(5 minutes) and safe procedure for analyzing quantitative fecal
fat is the hydrogen nuclear magnetic resonance spectroscopy
TECHNICAL TIP Failure to allow stool samples to soak
into the filter paper slide for 3 to 5 minutes before adding
developer may result in a false-negative result.
SUMMARY 14-1
gFOBT Interference
False-Positive
Aspirin and anti-inflammatory medications
Red meat
Horseradish
Raw broccoli, cauliflower, radishes, turnips
Melons
Menstrual and hemorrhoid contamination
False-Negative
Vitamin C >250 mg/d
Iron supplements containing vitamin C
Failure to wait specified time after sample is applied to
add the developer reagent
3920_Ch14_255-268 23/01/14 10:39 AM Page 263
Chapter 14 | Fecal Analysis
(1H NMR) method. In this method the homogenized specimen
is microwaved-dried and analyzed. The results correlate well
with the gravimetric method.16
The fat content is reported as grams of fat or the coefficient
of fat retention per 24 hours. Reference values based on a
100 g/d intake are 1 to 6 g/d or a coefficient of fat retention of at
least 95%. The coefficient of fat retention is calculated as follows:
(dietary fat – fecal fat)
× 100
(dietary fat)
Although the Van de Kamer titration is the gold standard for
fecal fat, the acid steatocrit is a rapid test to estimate the amount
of fat excretion. It is similar to the microhematocrit test and is
more convenient than a 72-hour stool collection. The acid steatocrit is a reliable tool to monitor a patient’s response to therapy
and screen for steatorrhea in pediatric populations.17,18
PROCEDURE 14-5
Acid Steatocrit
1. Dilute 0.5 g of feces from a spot collection 1 to 4
with deionized water.
2. Vortex for 2 minutes to homogenize the specimen.
3. Add a volume of 5 N perchloric acid equal to 20% of
the homogenate and then vortex the mixture for 30
seconds. Confirm the pH to be <1.
4. Place the acid-homogenate mixture in a 75-µL plain
hematocrit capillary tube. Seal the end with wax.
5. Centrifuge the capillary tube horizontally at 13,000
rpm for 15 minutes in a microhematocrit centrifuge.
This separates fat as an upper layer overlying a solid
fecal layer.
6. Measure the length of the fat and solid layers using a
magnifying lens.
7. Calculate the acid steatocrit in percent.
8. Calculate the fecal fat in grams per 24 hours.
The acid steatocrit in percent = (fatty layer length in
cm)/[(fatty layer length in cm) + (solid layer length)] × 100
The fecal fat for adults is quantitated as follows:
Fecal fat in grams per 24 hours = [0.45 × (acid steatocrit
in percent as a whole number)] – 0.43
An acid steatocrit value <31% is considered normal
while a value >31% indicates steatorrhea in adults.
The fecal fat for children up to the age of 15 years is as
follows:
Fecal fat in grams per 24 hours = [0.1939 × (acid
steatocrit in percent as a whole number)] – 0.2174
Acid steatocrit is higher in infants and lowers with age.19
An acid steatocrit of <10% indicates steatorrhea in
children.18
263
Near-infrared reflectance spectroscopy (NIRS) is a rapid
procedure for fecal fat that requires less stool handling by
laboratory personnel. The test requires a 48- to 72-hour
stool collection to exclude day-to-day variability, but it does
not require reagents after homogenization of the sample. The
result is based on the measurement and computed processing of signal data from reflectance of fecal surface, which is
scanned with infrared light between 1400 nM and 2600 nM
wavelength. The results are calculated from calibration derived from known samples. The technique quantitates water,
fat, and nitrogen in grams per 24 hours.20 A summary of tests
and current instrumentation for fecal fat analysis is presented
in Table 14–4.
APT Test (Fetal Hemoglobin)
Grossly bloody stools and vomitus are sometimes seen in
neonates as the result of swallowing maternal blood during delivery. Should it be necessary to distinguish between the presence of fetal blood or maternal blood in an infant’s stool or
vomitus, the APT test may be requested.
The material to be tested is emulsified in water to release
hemoglobin (Hb) and, after centrifugation, 1% sodium hydroxide is added to the pink hemoglobin-containing supernatant. In the presence of alkali-resistant fetal hemoglobin, the
solution remains pink (HbF), whereas denaturation of the maternal hemoglobin (HbA) produces a yellow-brown supernatant after standing for 2 minutes. The APT test distinguishes
not only between HbA and HbF but also between maternal hemoglobins AS, CS, and SS and HbF. The presence of maternal
thalassemia major would produce erroneous results owing to
the high concentration of HbF. Stool specimens should be
tested when fresh. They may appear bloody but should not be
black and tarry, because this would indicate already denatured
hemoglobin.21
Table 14–4
Tests, Materials, and Instrumentation for
Fecal Fat Analysis19
Procedure
Materials, Instrumentation
Sudan III
Steatocrit and
acid steatocrit
Fecal elastase–I
Near-infrared
reflectance
spectroscopy
(NIRS)
Van de Kamer
titration
Sudan stain, microscopy
Hematocrit centrifuge, gravimetric
assay
Immunoassay ELISA technique
NIRS spectrophotometer with
specialized computer software
Nuclear magnetic
resonance
spectroscopy
Fecal fat extraction and titration of
long chain fatty acid by sodium
hydroxide
Microwaved-dried specimen; hydrogen nuclear magnetic spectrophotometer
3920_Ch14_255-268 23/01/14 10:39 AM Page 264
264
Part Three | Other Body Fluids
PROCEDURE 14-6
APT Test
1.
2.
3.
4.
5.
6.
7.
Emulsify specimen in water.
Centrifuge.
Divide pink supernatant into two tubes.
Add 1% sodium hydroxide to one tube.
Wait 2 minutes.
Compare color with that in the control tube.
Prepare controls using cord blood and adult blood.
Fecal Enzymes
Enzymes supplied to the gastrointestinal tract by the pancreas
are essential for digesting dietary proteins, carbohydrates, and
fats. Decreased production of these enzymes (pancreatic insufficiency) is associated with disorders such as chronic pancreatitis and cystic fibrosis. Steatorrhea occurs, and undigested
food appears in the feces.
Analysis of the feces focuses primarily on the proteolytic
enzymes trypsin, chymotrypsin, and elastase I.
Fecal chymotrypsin is more resistant to intestinal degradation and is a more sensitive indicator of less severe cases of
pancreatic insufficiency. It also remains stable in fecal specimens for up to 10 days at room temperature. Chymotrypsin is
capable of gelatin hydrolysis but is most frequently measured
by spectrophotometric methods.
Elastase I is an isoenzyme of the enzyme elastase and is
the enzyme form produced by the pancreas. It is present in
high concentrations in pancreatic secretions and is strongly resistant to degradation. It accounts for about 6% of all secreted
pancreatic enzymes.22 Fecal elastase I is pancreas specific and
its concentration is about five times higher than in pancreatic
juice. It is not affected by motility disorders or mucosal
defects.23 Elastase I can be measured by immunoassay using
HISTORICAL NOTE
Screening Test for Fecal Trypsin
Historically, absence of trypsin has been screened for by
exposing x-ray paper to stool emulsified in water. When
trypsin is present in the stool, it digests the gelatin on the
paper, leaving a clear area. Inability to digest the gelatin
indicates a deficiency in trypsin production. The gelatin
test is an insensitive procedure that detects only severe
cases of pancreatic insufficiency. In addition, false-negative
results may occur as the result of intestinal degradation of
trypsin and the possible presence of trypsin inhibitors in
the feces. The proteolytic activity of bacteria enzymes may
produce false-positive results in old specimens.
the ELISA kit and provides a very sensitive indicator of exocrine pancreatic insufficiency.24,25 It is easy to perform and
requires only a single stool sample. The ELISA test uses monoclonal antibodies against human pancreatic elastase-1; therefore, the result is specific for human enzyme and not affected
by pancreatic enzyme replacement therapy.22 The test is specific in differentiating pancreatic from nonpancreatic causes in
patients with steatorrhea.23
Carbohydrates
The presence of increased carbohydrates in the stool produces osmotic diarrhea from the osmotic pressure of the unabsorbed sugar in the intestine drawing in fluid and
electrolytes. Carbohydrates in the feces may be present as a
result of intestinal inability to reabsorb carbohydrates, as is
seen in celiac disease, or lack of digestive enzymes such as
lactase resulting in lactose intolerance. Idiopathic lactase
deficiency is common, predominantly occurring in the
African, Asian, and southern European Greek populations.
Carbohydrate malabsorption or intolerance (maldigestion)
is primarily analyzed by serum and urine tests; however, an
increased concentration of carbohydrate can be detected by
performing a copper reduction test on the fecal specimen.
Testing for fecal reducing substances detects congenital disaccharidase deficiencies as well as enzyme deficiencies due
to nonspecific mucosal injury. Fecal carbohydrate testing is
most valuable in assessing cases of infant diarrhea and may
be accompanied by a pH determination. Normal stool pH is
between 7 and 8; however, increased use of carbohydrates
by intestinal bacterial fermentation increases the lactic acid
level and lowers the pH to below 5.5 in cases of carbohydrate disorders.
The copper reduction test is performed using a Clinitest
tablet (Siemens Healthcare Diagnostics, Inc., Deerfield, IL)
and one part stool emulsified in two parts water. A result of
0.5 g/dL is considered indicative of carbohydrate intolerance. The Clinitest on stools can distinguish between diarrhea caused by abnormal excretion of reducing sugars and
those caused by various viruses and parasites. Sucrose is not
detected by the Clinitest method because it is not a reducing
sugar. In premature infants there is correlation between
a positive Clinitest and inflammatory necrotizing enterocolitis. As discussed in Chapter 5, this is a general test for
the presence of reducing substances, and a positive result
would be followed by more specific serum carbohydrate tolerance tests, the most common being the D-xylose test
for malabsorption and the lactose tolerance test for maldigestion. Stool chromatography to identify the malabsorbed
carbohydrate is available but rarely necessary to diagnose
sugar intolerance. Small-bowel biopsy specimens for histologic examination and the assay of disaccharidase enzyme
activity differentiate primary from secondary disaccharidase
intolerance.26
A summary of fecal screening tests is presented in
Table 14–5.
3920_Ch14_255-268 23/01/14 10:39 AM Page 265
Chapter 14 | Fecal Analysis
Table 14–5
265
Fecal Screening Tests
Test
Methodology/Principle
Interpretation
Examination for
neutrophils
Qualitative
fecal fats
Microscopic count of neutrophils in smear stained with
methylene blue, Gram stain, or Wright's stain
Microscopic examination of direct smear stained with
Sudan III
Microscopic examination of smear heated with acetic
acid and Sudan III
Pseudoperoxidase activity of hemoglobin liberates oxygen from hydrogen peroxide to oxidize guaiac reagent
Uses polyclonal anti-human antibodies specific for the
globin portion of human hemoglobin
Addition of sodium hydroxide to hemoglobin-containing
emulsion determines presence of maternal or fetal blood
Emulsified specimen placed on x-ray paper determines
ability to digest gelatin
Immunoassay using an ELISA test
Three per high-power field indicates
condition affecting intestinal wall
60 large orange-red droplets indicates
malabsorption
100 orange-red droplets measuring
6 to 75 µm indicates malabsorption
Blue color indicates gastrointestinal
bleeding
Positive test and control lines indicate GI
bleeding
Pink color indicates presence of fetal blood
gFOBT
iFOBT
APT test
Trypsin
Elastase 1
Clinitest
Addition of Clinitest tablet to emulsified stool detects
presence of reducing substances
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Singh, A, Gull, H, and Singh, R: Clinical significance of rapid
(accelerated) gastric emptying. Clin Nucl Med 28(8):652–658,
2003.
2. Ukleja, A: Dumping syndrome: Pathophysiology and treatment.
Nutr Clin Pract 20(5):517–525, 2005.
3. Koepke, JA: Tips from the clinical experts. MLO, p. 15, 1995.
4. Bradley, GM: Fecal analysis: Much more than an unpleasant
necessity. Diagn Med 3(2):64–75, 1980.
5. Novak, R, et al: How useful are fecal neutrophil determinations?
Lab Med 26(11):433, 1995.
6. McCray, WH, and Krevsky, B: Diagnosing diarrhea in adults:
A practical approach. Hosp Med 34(4):27–36, 1998.
7. Walters, MP, et al: Clinical monitoring of steatorrhea in cystic
fibrosis. Arch Dis Child 65:99–102, 1990.
8. Khouri, MR, Huang, G, and Shiau, YF: Sudan stain of fecal fat:
New insight into an old test. Gastroenterology 96(2 Pt 1):
421–427, 1990.
9. Simko, V: Fecal fat microscopy. Am J Gastroenterol 75(3):
204–208, 1981.
10. Van de Kamer, JH, et al: A rapid method for determination of
fat in feces. J Biol Chem 177:347–355, 1949.
11. Freeman, JA, and Beeler, MF: Laboratory Medicine: Urinalysis
and Medical Microscopy. Lea & Febiger, Philadelphia, 1983.
12. Drummey, GD, Benson, JA, and Jones, CM: Microscopic examination of the stool for steatorrhea. N Engl J Med 264:85–87, 1961.
13. Mandel, JS, et al: The effect of fecal occult-blood screening on
the incidence of colorectal cancer. N Engl J Med 343(22):
1603–1607, 2000.
Inability to digest gelatin indicates lack
of trypsin
Sensitive indicator of exocrine pancreatic
insufficiency
Reaction of 0.5 g/dL reducing substances
suggests carbohydrate
intolerance
14. Knight, KK, Fielding, JE, and Battista, RN: Occult blood
screening for colorectal cancer. JAMA 261:587–590, 1989.
15. Hemoccult ICT immunochemical fecal occult blood
test package insert. Beckman Coulter, Fullerton, CA,
May 2005.
16. Korpi-Steiner, N, Ward, JN, Kumar, V, and McConnell, JP:
Comparative analysis of fecal fat quantitation via nuclear
magnetic resonance spectroscopy (1H NMR and gravimetry.
Clin Chim Acta 400:33, 2009.
17. Bijoor, AR, Geetha, S, and Venkateash, T: Faecal fat content in
healthy adults by the “acid steatocrit method.” Indian J Clin
Biochem 19(2):20–22, 2004.
18. Van den Neucker, AM, et al: Acid steatocrit: a reliable screening
tool for steatorrhoea. Acta Paediatr 90:873–875, 2001.
19. Guarino, A, et al: Reference values of the steatocrit and its
modifications in diarrheal diseases. J Pediatr Gastroenterol
Nutr 14:268–274, 1992.
20. Serrano, PL, Navarro, JLL, and Fernandez-Rodriguez, CM:
Laboratory tests and equipment for diagnostic work-up for
malabsorption syndrome. LABTECH 2004.
21. Croak, M: Haemoglobin in stools from neonates: Measurement
by a modified APT test. Med Lab Sci 48(4):346–350, 1991.
22. Elphick, DA, and Kapur, K: Comparing the urinary pancreolauryl ratio and faecal elastase-1 as indicators of pancreatic insufficiency in clinical practice. Pancreatology 5:196–200, 2005.
23. Symersky, T, et al: Faecal elastase-I: Helpful in analysing
steatorrhoea? Neth J Med 62(8):286–289, 2004.
24. Phillips, IJ, et al: Faecal elastase I: A marker of exocrine
pancreatic insufficiency in cystic fibrosis. Ann Clin Chem
36:739–742, 1999.
25. Thorne, D, and O’Brien, C: Diagnosing chronic pancreatitis.
Advance 12(14):8–12, 2000.
26. Robayo-Torres, CC, Quezada-Calvillo, R, and Nichols, BL:
Disaccharide digestion: Clinical and molecular aspects. Clin
Gastroenterol Hepatol 4(3):276–287, 2006.
3920_Ch14_255-268 23/01/14 10:39 AM Page 266
266
Part Three | Other Body Fluids
Study Questions
1. In what part of the digestive tract do pancreatic enzymes
and bile salts contribute to digestion?
8. Stools from persons with steatorrhea will contain excess
amounts of:
A. Large intestine
A. Barium sulfate
B. Liver
B. Blood
C. Small intestine
C. Fat
D. Stomach
D. Mucus
2. Where does the reabsorption of water take place in the
primary digestive process?
A. Large intestine
B. Pancreas
C. Small intestine
D. Stomach
3. Which of the following tests is not performed to detect
osmotic diarrhea?
A. Clinitest
B. Fecal fats
C. Fecal neutrophils
D. Muscle fibers
4. The normal composition of feces includes all of the following
except:
9. Which of the following pairings of stool appearance and
cause does not match?
A. Black, tarry: blood
B. Pale, frothy: steatorrhea
C. Yellow-gray: bile duct obstruction
D. Yellow-green: barium sulfate
10. Stool specimens that appear ribbon-like are indicative of
which condition?
A. Bile-duct obstruction
B. Colitis
C. Intestinal constriction
D. Malignancy
11. A black tarry stool is indicative of:
A. Bacteria
A. Upper GI bleeding
B. Blood
B. Lower GI bleeding
C. Electrolytes
C. Excess fat
D. Water
D. Excess carbohydrates
5. What is the fecal test that requires a 3-day specimen?
A. Fecal occult blood
12. Chemical screening tests performed on feces include all
of the following except:
B. APT test
A. APT test
C. Elastase I
B. Clinitest
D. Quantitative fecal fat testing
C. Pilocarpine iontophoresis
6. The normal brown color of the feces is produced by:
A. Cellulose
D. Quantitative fecal fats
13. Secretory diarrhea is caused by:
B. Pancreatic enzymes
A. Antibiotic administration
C. Undigested foodstuffs
B. Lactose intolerance
D. Urobilin
7. Diarrhea can result from all of the following except:
A. Addition of pathogenic organisms to the normal
intestinal flora
C. Celiac sprue
D. Vibrio cholerae
14. The fecal osmotic gap is elevated in which disorder?
B. Disruption of the normal intestinal bacterial flora
A. Dumping syndrome
C. Increased concentration of fecal electrolytes
B. Osmotic diarrhea
D. Increased reabsorption of intestinal water and
electrolytes
C. Secretory diarrhea
D. Steatorrhea
3920_Ch14_255-268 23/01/14 10:39 AM Page 267
Chapter 14 | Fecal Analysis
15. Microscopic examination of stools provides preliminary
information as to the cause of diarrhea because:
A. Neutrophils are present in conditions caused by
toxin-producing bacteria
B. Neutrophils are present in conditions that affect the
intestinal wall
C. Red and white blood cells are present if the cause is
bacterial
D. Neutrophils are present if the condition is of nonbacterial etiology
16. True or False: The presence of fecal neutrophils would be
expected with diarrhea caused by a rotavirus.
17. Large orange-red droplets seen on direct microscopic
examination of stools mixed with Sudan III represent:
A. Cholesterol
B. Fatty acids
C. Neutral fats
D. Soaps
18. Microscopic examination of stools mixed with Sudan III
and glacial acetic acid and then heated will show small
orange-red droplets that represent:
A. Fatty acids and soaps
B. Fatty acids and neutral fats
C. Fatty acids, soaps, and neutral fats
D. Soaps
19. When performing a microscopic stool examination for
muscle fibers, the structures that should be counted:
A. Are coiled and stain blue
B. Contain no visible striations
C. Have two-dimensional striations
D. Have vertical striations and stain red
20. A value of 85% fat retention would indicate:
A. Dumping syndrome
B. Osmotic diarrhea
C. Secretory diarrhea
D. Steatorrhea
21. Which of the following tests would not be indicative of
steatorrhea?
A. Fecal elastase-I
B. Fecal occult blood
C. Sudan III
D. Van de Kamer
22. The term “occult” blood describes blood that:
A. Is produced in the lower GI tract
B. Is produced in the upper GI tract
C. Is not visibly apparent in the stool specimen
D. Produces a black, tarry stool
267
23. What is the recommended number of samples that should
be tested to confirm a negative occult blood result?
A. One random specimen
B. Two samples taken from different parts of three
stools
C. Three samples taken from the outermost portion of
the stool
D. Three samples taken from different parts of two
stools
24. The immunochemical tests for occult blood:
A. Test for human globulin
B. Give false-positive reactions with meat hemoglobin
C. Can give false-positive reactions with aspirin
D. Are inhibited by porphyrin
25. Guaiac tests for detecting occult blood rely on the:
A. Reaction of hemoglobin with hydrogen peroxide
B. Pseudoperoxidase activity of hemoglobin
C. Reaction of hemoglobin with ortho-toluidine
D. Pseudoperoxidase activity of hydrogen peroxide
26. What is the significance of an APT test that remains pink
after addition of sodium hydroxide?
A. Fecal fat is present.
B. Fetal hemoglobin is present.
C. Fecal trypsin is present.
D. Vitamin C is present.
27. In the Van de Kamer method for quantitative fecal fat
determinations, fecal lipids are:
A. Converted to fatty acids prior to titrating with
sodium hydroxide
B. Homogenized and titrated to a neutral endpoint with
sodium hydroxide
C. Measured gravimetrically after washing
D. Measured by spectrophotometer after addition of
Sudan III
28. A patient whose stool exhibits increased fats, undigested
muscle fibers, and the inability to digest gelatin may
have:
A. Bacterial dysentery
B. A duodenal ulcer
C. Cystic fibrosis
D. Lactose intolerance
3920_Ch14_255-268 23/01/14 10:39 AM Page 268
268
Part Three | Other Body Fluids
29. A stool specimen collected from an infant with diarrhea
has a pH of 5.0. This result correlates with a:
A. Positive APT test
B. Negative trypsin test
C. Positive Clinitest
D. Negative occult blood test
30. Which of the following tests differentiates a malabsorption cause from a maldigestion cause in steatorrhea?
A. APT test
B. D-xylose test
C. Lactose tolerance test
D. Occult blood test
Case Studies and Clinical Situations
1. Microscopic screening of a stool from a patient exhibiting
prolonged diarrhea shows increased fecal neutrophils and
normal qualitative fecal fats and meat fibers.
a. What type of diarrhea do these results suggest?
b. Name an additional test that could provide more diagnostic information.
c. Name one probable result for this test and one improbable result.
d. If the test for fecal neutrophils were negative and the
fecal fat concentration increased, what type of diarrhea
would be suggested?
2. Laboratory studies are being performed on a 5-year-old
boy to determine whether there is a metabolic reason for
his continued failure to gain weight. In addition to having
blood drawn, the patient has a sweat chloride collected,
provides a random stool sample, and is asked to collect a
72-hour stool sample.
a. How can the presence of steatorrhea be screened for
by testing the random stool sample?
b. How does this test distinguish among neutral fats,
soaps, and fatty acids?
c. What confirmatory test should be performed?
d. Describe the appearance of the stool specimens if
steatorrhea is present.
e. If a diagnosis of cystic fibrosis is suspected, state two
screening tests that could be performed on a stool
specimen to aid in the diagnosis.
f. State a possible reason for a false-negative reaction in
each of these tests.
g. What confirmatory test could be performed?
3. A physician’s office laboratory is experiencing inconsistencies in the results of patient-collected specimens for
FOBT. Patients are instructed to submit samples from two
areas of three different stools. Positive and negative controls are producing satisfactory results. Patient #1 is a 30year-old woman taking over-the-counter medications for
gastric reflux who has reported passing frequent, black
stools. The results of all three specimens are negative for
occult blood. Patient #2 is a 70-year-old woman suffering
from arthritis. She is taking the test as part of a routine
physical. The results of all three specimens are positive
for occult blood. Patient #3 is a 50-year-old man advised
by the doctor to lose 30 lb. He has been doing well on a
high-protein, low-carbohydrate diet. Two of his three
specimens are positive for occult blood.
a. What is the possible nonpathologic cause of the unexpected results for Patient #1? Patient #2? Patient #3?
b. How could the physician’s office staff avoid these discrepancies?
c. What testing methodology could be used for Patients #2
and #3?
4. A watery black stool from a neonate is received in the laboratory with requests for an APT test, fecal pH, and a
Clinitest.
a. Can all three tests be performed on this specimen?
Why?
b. If the Clinitest is positive, what pH reading can be
expected? Why?
c. The infant’s hemoglobin remains constant at 18 g/dL.
What was the significance of the black stool?
d. Would this infant be expected to have ketonuria? Why
or why not?
3920_Ch15_269-282 23/01/14 10:40 AM Page 269
CHAPTER
15
Vaginal Secretions
LEARNING OBJECTIVES
Upon completing this chapter, the reader will be able to:
15-1 State the indications for collecting vaginal specimens.
15-2 Describe the specimen collection and handling procedures for vaginal specimens and explain how deviations
from the correct practice will affect test results.
15-3 Describe the appearance of normal and abnormal
vaginal secretions.
15-4 Explain the significance of vaginal pH values.
15-5 List the diagnostic tests performed on vaginal
secretions and explain the appropriate use for each.
15-6 Describe the microscopic constituents for the common
syndromes associated with vaginitis.
15-7 Identify the most common causes of vaginitis including
the cause, clinical signs and symptoms, laboratory
tests, and treatment.
15-8 Describe two tests that can be performed on vaginal
secretions to predict conditions of premature delivery
and rupture of fetal membranes.
KEY TERMS
Atrophic vaginitis
Dysuria
Trichomonas vaginalis
Bacterial vaginosis (BV)
Gardnerella vaginalis
Trichomoniasis
Basal cells
Lactobacilli
Vaginal pool
Clue cells
Mobiluncus spp.
Vaginitis
Desquamative inflammatory
vaginitis (DIV)
Parabasal cells
Vulvovaginal candidiasis
Pruritus
Yeast
Dyspareunia
3920_Ch15_269-282 23/01/14 10:40 AM Page 270
270
Part Three | Other Body Fluids
Vaginal secretions are examined in the clinical laboratory to diagnose infections and complications of pregnancy, and for
forensic testing (see Chapter 10, Semen) in sexual assault patients. In this chapter, the most commonly encountered disorders and the diagnostic laboratory tests used to evaluate vaginal
secretions will be discussed.
Vaginitis is one of the most common conditions diagnosed
by health-care providers for female patients, particularly women
of childbearing age. It is characterized by abnormal vaginal discharge or odor, pruritus, vaginal irritation, dysuria, and dyspareunia. Most often, vaginitis is secondary to bacterial
vaginosis (BV), vulvovaginal candidiasis, or trichomoniasis;
however, vaginitis can also occur with non-infectious conditions
such as vaginal atrophy, allergies, and chemical irritation.1
Although the symptoms for the various syndromes of
vaginitis are similar, the effective treatment for each depends
on an accurate diagnosis. Careful microscopic examination
of fresh vaginal secretions is necessary to determine the
causative agent for each syndrome and to provide the appropriate treatment for the patient and, in some cases, the sexual
partners, to avoid reinfection. Microscopic methods include
a saline wet mount examination, potassium hydroxide
(KOH) examination, and the Gram stain, which is considered the gold standard. Clinical laboratory personnel performing urine microscopic examinations should be aware
that microscopic constituents observed in vaginal fluid may
also be seen in urine specimens when the urine specimen is
contaminated with vaginal secretions. Other tests used for
differential diagnosis include litmus pH levels, DNA probe
testing, culture, and point of care test kits. The clinical and
microscopic features of the common syndromes are summarized in Table 15–1.
Table 15–1
Findings
Appearance
pH
WBCs
Lactobacilli
Clue cells
Other cells
In addition to evaluating vaginal secretions for infections,
tests are performed on vaginal secretions to detect the placental
␣ 1-microglobulin (PAMG-1) protein to diagnose ruptured fetal
membranes, or fetal fibronectin enzyme to assess the risk of
preterm delivery. The fern test (see Chapter 13) is used to identify amniotic fluid that may be present when the amniotic sac
has ruptured.2
Specimen Collection
and Handling
The health-care provider collects vaginal secretions during a
pelvic examination. Detailed instructions and the specific manufacturer’s collection and transport devices must be provided
and are specific to the organism sought. Correct specimen handling and timely transport to the laboratory is important for
optimal detection of the responsible pathogen.
A speculum moistened with warm water is used to visualize the vaginal fornices. Lubricants may contain antibacterial
agents and must not be used. The specimen is collected by
swabbing the vaginal walls and vaginal pool to collect epithelial cells along with the vaginal secretions using one or more
sterile, polyester-tipped swabs on a plastic shaft or swabs
specifically designated by the manufacturer.3 Cotton swabs
should not be used because cotton is toxic to Neisseria gonorrhoeae, the wood in a wooden shaft may be toxic to Chlamydia
trachomatis, and calcium alginate can inactivate herpes simplex
virus (HSV) for viral cultures.4
The health-care provider performs a gross examination of
the vaginal secretions and then places the swab in a tube containing 0.5 to 1.0 mL of sterile physiologic saline. The tube is
Clinical Features and Laboratory Findings in Vaginitis2
Bacterial
Vaginosis
Candidiasis
Trichomoniasis
Thin, homogeneous, whiteto-gray
vaginal
discharge
>4.5
Rare or absent
Rare or absent
White, curd-like
vaginal
discharge
Yellow-green
frothy adherent
vaginal discharge
increased in
volume
>4.5
2+ to 4+
Absent or present
>20%
Absent
Large clumps of
epithelial cells
3.8 to 4.5
3+ to 4+
Present
Desquamative
Inflammatory
Vaginitis
Atrophic
Vaginitis
Excessive purulent vaginal
discharge,
vaginal
erythema
>4.5
3+ to 4+
Absent or
reduced
Excessive purulent vaginal
discharge,
vaginal
erythema
>4.5
3+ to 4+
Decreased
Occasional
parabasal or
basal cells
>1+ RBCs
Occasional
parabasal or
basal cells
>1+ RBCs
Absent or present
3920_Ch15_269-282 23/01/14 10:40 AM Page 271
Chapter 15 | Vaginal Secretions
Table 15–1
Findings
271
Clinical Features and Laboratory Findings in Vaginitis2—cont’d
Bacterial
Vaginosis
Candidiasis
Trichomoniasis
Desquamative
Inflammatory
Vaginitis
Other
organisms
Increase in small
curved bacilli,
coccobacilli,
and pleomorphic bacilli
Budding yeast
cells and
pseudohyphae
Trichomonas
frequently
associated with
other organisms
2+ grampositive cocci
Amine (Whiff)
test
Other tests
Positive
Negative
Positive
Negative
Confirmatory
tests: DNA
probe, proline amino
peptidase,
OSOM
BVBLUE
Rapid Test
Confirmatory
tests: DNA
probe, OSOM
BVBLUE Rapid
Test
Confirmatory
tests: DNA
probe or
culture, OSOM
Trichomonas
Rapid Test
sealed for transport to the laboratory, where the specimen is
processed for microscopic analysis. The swab should be vigorously twirled in the saline to dislodge particulates from the
swab. Failure to dislodge particles may lead to erroneous results. Specimens should be tested with pH paper before being
placed in saline.2 An alternative method of specimen preparation is to dilute a sample of vaginal discharge in one to two
drops of normal saline solution directly on a microscope slide.
A second sample is then placed in 10% KOH solution in the
same manner. Cover slips are placed over both slides for microscopic examination.5
Properly labeled specimens should be placed in a biohazard
bag with the requisition and transported to the laboratory as
soon as possible. The requisition must include the patient’s name
and unique identifier as well as a patient medical history that
should include menstrual status; use of vaginal creams, lubricants, and douches; and recent exposure to sexually transmitted
diseases.3 Specimens should be analyzed immediately, but if a
delay in transport or analysis is necessary, specimen handling
is based on the suspected pathogen. Specimens must be kept
at room temperature to preserve the motility of Trichomonas
vaginalis and the recovery of N. gonorrhoeae, whereas specimens
for C. trachomatis and herpes simplex virus must be refrigerated
to prevent overgrowth of normal flora.4 Specimens for T. vaginalis
should be examined within 2 hours of collection.2
Color and Appearance
Normal vaginal fluid appears white with a flocculent discharge.
Microscopically, normal vaginal flora includes a predominance
of large, rod-shaped, gram-positive lactobacilli and squamous
Atrophic
Vaginitis
Increased grampositive cocci
and gramnegative rods;
decreased
large rods
Negative
epithelial cells. White blood cells may be present and red blood
cells will be present if the patient is menstruating3 (Table 15–2).
Abnormal vaginal secretions may appear as an increased
thin, homogeneous white-to-gray discharge often seen in bacterial vaginosis, or as a white “cottage cheese”–like discharge
particular for Candida infections, or as an increased yellow-green,
frothy, adherent discharge associated with T. vaginalis.3 C.
trachomatis may present with a yellow, opaque cervical discharge.6
Diagnostic Tests
pH
The health-care provider can perform a vaginal pH test when
performing a pelvic examination. The test should be performed before placing the swab into saline or KOH solutions.
Table 15–2
Normal Findings in Vaginal Secretions
Appearance
pH
Amine (Whiff) test
WBCs
Lactobacilli
Clue cells
Other cells
Other organisms
White, flocculent discharge
3.8 to 4.2
Negative
2+
Predominant
Absent
Absent (except RBCs during
menses)
Other lactobacilli subgroups,
occasional yeast
3920_Ch15_269-282 23/01/14 10:40 AM Page 272
272
Part Three | Other Body Fluids
Commercial pH test paper with a narrow pH range is recommended to more accurately evaluate pH values in the 4.5 range.
The test paper is placed in the pooled vaginal secretion and
the color change is compared to a chart with corresponding
pH values. Factors that can interfere with the pH test include
contamination of the vaginal secretions with cervical mucus,
semen, and blood.6
The pH test helps to differentiate the causes of vaginitis,
as shown in Table 15–1. The vaginal pH is usually about 4.5
in women with vulvovaginal candidiasis but is above 4.5 in
women with bacterial vaginosis, trichomoniasis, desquamative
inflammatory vaginitis (DIV), and atrophic vaginitis.1,2,4
As described previously, normal vaginal flora includes a
predominance of the bacteria lactobacilli, which produce the
end product lactic acid from glycogen metabolism. Lactic acid
provides an acidic vaginal environment with a pH value between 3.8 and 4.5. This acidity suppresses the overgrowth of
infectious organisms such as Mobiluncus, Prevotella, and Gardnerella vaginalis, and therefore maintains the balance of normal vaginal bacteria flora.7 Some lactobacilli subgroups also
produce hydrogen peroxide, which is toxic to pathogens, and
helps keep the vaginal pH acidic to provide protection from
urogenital infections. Bacterial vaginosis has been associated
with the absence of hydrogen peroxide–producing lactobacilli.3
Estrogen production also is necessary to preserve an acidic
vaginal environment.6
Microscopic Procedures
Vaginal infections are usually diagnosed from microscopic
examination. Saline wet mounts and KOH mounts are the initial
screening tests and the Gram stain is used as a confirmatory
examination for yeast or bacterial vaginosis.2 Slides are prepared
from the saline specimen solution that was made from the vaginal swab immediately after collection. Three clean glass slides
(if a Gram stain is requested) are labeled with the patient’s name
and a unique identifier. A drop of specimen is placed on each
slide using a disposable transfer pipette. An alternative method
is to press the swab against the slide and then roll the swab over
the slide. The slide for Gram stain is allowed to dry and then
heat-fixed for the Gram stain procedure and examination
performed in the microbiology section of the laboratory. For
wet mount examinations, cells and organisms are quantified
per high power field (hpf) (40×); for Gram stains, cells and
organisms are reported per oil immersion field (100×).
Wet Mount Examination
For the saline wet mount examination, a cover slip is placed on
the specimen carefully to exclude air bubbles. The slide is examined microscopically using the low power (10×) and high
dry power (40×) objective with a bright-field microscope. Using
the low power objective (100×magnification), the slide is
scanned for an even distribution of cellular components, types
and numbers of epithelial cells, clumping of epithelial cells, and
the presence of budding yeast or pseudohyphae. The slide is
then examined using the high power objective (400× magnification) and the organisms and cells are counted and reported
per high power field (hpf) using the criteria in Table 15–3.
Typical constituents found in vaginal fluid wet mounts include squamous epithelial cells, white blood cells, red blood
cells, clue cells, parabasal cells, basal cells, bacteria, motile
Trichomonas vaginalis, yeast, and hyphae/pseudohyphae.
Intravaginal medications might leave oil droplets that can
interfere with the interpretation of wet mounts. In this case, a
Gram stain is useful to detect yeast or bacterial vaginosis.2
Squamous Epithelial Cells
Squamous epithelial cells measure 25 to 70 µm in diameter
and exhibit a polygonal “flagstone” appearance. They contain
a prominent centrally located nucleus about the size of a red
blood cell and a large amount of irregular cytoplasm, lacking
granularity, with distinct cell margins. (Fig. 15–1) These large,
flat cells originate from the linings of the vagina and female
urethra and are present in significant numbers in the vaginal
Table 15–3
Rare
1+
2+
3+
4+
Quantitation Scheme for Microscopic
Examinations 2
Less than 10 organisms or cells/slide
Less than 1 organism or cell/hpf
1 to 5 organisms or cells/hpf
6 to 30 organisms or cells/hpf
>30 organisms or cells/hpf
PROCEDURE 15-1
pH Test
1. Using a circular motion, gently apply the vaginal
secretion over the surface of the pH test paper.
2. Immediately observe the color reaction on the paper
and compare the color to a color comparison chart to
determine the pH of the sample.
3. Record the results.
Figure 15–1 Squamous epithelial cells identifiable under low power
(×100).
3920_Ch15_269-282 23/01/14 10:40 AM Page 273
Chapter 15 | Vaginal Secretions
273
secretions of a healthy female. Clumps of epithelial cells as
observed in Figure 15–2 are an indication of the presence of
increased numbers of yeast.3
Clue Cells
Clue cells are an abnormal variation of the squamous epithelial
cell and are distinguished by coccobacillus bacteria attached
in clusters on the cell surface, spreading past the edges of the
cell, making the border indistinct or stippled. This gives the
cell a granular, irregular appearance sometimes described as
“shaggy.” Clue cells are diagnostic of bacterial vaginosis caused
by G. vaginalis (Fig. 15–3). The presence of clue cells also can
be found in urine sediment, and should be confirmed by the
procedures already described.
White Blood Cells
White blood cells (WBCs) measure 14 to 16 µm in diameter
and exhibit a granular cytoplasm. They are often described as
polymorphonuclear white blood cells (PMNs) because of their
characteristic multi-lobed nucleus (Fig. 15–4). In health, WBCs
are present in rare to scanty numbers in vaginal secretions.
Greater than 3+ WBCs in vaginal secretions suggest vaginal candidiasis, atrophic vaginitis, or infections with Trichomonas,
Chlamydia, N. gonorrhoeae, or Herpes simplex.3
Figure 15–2 Clump of squamous epithelial cells (×400).
Figure 15–3 Clue cells (×400).
Figure 15–4 White blood cells. Notice the multilobed nucleoli
(×400).
Red Blood Cells
Red blood cells (RBCs) appear as smooth, non-nucleated
biconcave disks measuring approximately 7 to 8 µm in
diameter (Fig. 15–5). RBCs can be somewhat distorted in
vaginal specimens. RBCs are not usually seen in vaginal
secretions, but they might be present during menstruation
or due to a desquamative inflammatory process. 2 RBCs can
be confused with yeast cells and are distinguished from yeast
cells by KOH, which will lyse the RBCs but allow the yeast
cells to remain intact.
Parabasal Cells
Parabasal cells are round to oval shaped and measure
16 to 40 µm in diameter. The nucleus to cytoplasm ratio is
1:1 to 1:2, with marked basophilic granulation or amorphic
basophilic structures (“blue blobs”) in the surrounding cytoplasm. They are located in the luminal squamous epithelium
of the vaginal mucosa. It is rare to find parabasal cells in
vaginal secretions but less mature cells may be found if the
patient is menstruating and in postmenopausal women.2
Increased numbers of parabasal cells, if present with large
numbers of WBCs, can indicate desquamative inflammatory
vaginitis2 (Fig. 15–6).
Figure 15–5 Normal red blood cells (×400).
3920_Ch15_269-282 23/01/14 10:40 AM Page 274
274
Part Three | Other Body Fluids
A
Figure 15–6 Parabasal cell surrounded by epithelial cells (×400).
Basal Cells
Basal cells are located deep in the basal layer of the vaginal
stratified epithelium. These cells are round and measure 10 to
16 µm in diameter and have a nucleus to cytoplasm ratio of
1:2. Basal cells are distinguished from WBCs that are similar
in size by their round rather than lobed nucleus. They are not
normally seen in vaginal fluid, and if present and accompanied
by large numbers of WBCs and altered vaginal flora can suggest
desquamative inflammatory vaginitis.2
Bacteria
The vagina is a nonsterile environment with complex endogenous bacterial flora that varies with the age and hormonal status
of the patient. Lactobacillus spp. normally comprise the largest
portion of vaginal bacteria.7 They appear as large gram-positive,
nonmotile rods on Gram stain and produce lactic acid, which
maintains the vaginal pH at 3.8 to 4.5 (Fig. 15–7 A and B).
Hydrogen peroxide, produced by lactobacilli subgroups, can also
help to suppress the overgrowth of other organisms. Other bacteria commonly present include anaerobic streptococci, diphtheroids, coagulase-negative staphylococci, and ␣ -hemolytic
streptococci. When conditions are present that cause an imbalance in the normal flora, vaginitis can occur. Absent or decreased
numbers of lactobacilli relative to the number of squamous
epithelial cells suggests an alteration in the normal flora. The lactobacilli are often replaced by increased numbers of Mobiluncus
spp. (thin, curved, gram-negative, motile rods), Prevotella spp.,
Porphyromonas spp., Bacteroides spp. (anaerobic gram-negative
rods), Gardnerella vaginalis (short, gram-variable coccobacilli),
Peptostreptococcus spp. (gram-positive cocci), Enterococcus spp.
(gram-negative cocci), Mycoplasma hominis, and Ureaplasma
urealyticum.
Trichomonas vaginalis
Trichomonas vaginalis is an atrial flagellated protozoan that can
cause vaginal inflammation and infection in women. The
organism is oval shaped, measures 5 to 18 µm in diameter, and
has four anterior flagella and an undulating membrane that
extends half the length of the body.8 An axostyle bisects the
B
Figure 15–7 Bacteria. A, Large rods characteristic of Lactobacilli, the
predominant bacteria in normal vaginal secretions (×400). B, Bacteria
with white blood cells (×400).
trophozoite longitudinally and protrudes from the posterior
end, which enables the organism to attach to the vaginal mucosal and cause tissue damage (Fig. 15–8). The “jerky” motion
of the flagella and undulating membrane characteristic of
T. vaginalis can be observed in a wet mount. Care must be taken
to not confuse T. vaginalis with sperm, which only have a single
tail, a much smaller head (approximately one half the diameter
of a RBC), and no axostyle. In addition, nonmotile trichomonads can be mistaken for WBCs (Fig. 15–9).
T. vaginalis organisms quickly lose their viability after collection. Specimens must be examined as soon as possible or, if necessary, maintained at room temperature for a maximum of 2 hours
before preparing the wet mount to observe the organism’s motility.
Trichomonas also can be seen in a urinary microscopic sample,
but cannot be reported unless motility is observed, either in movement across the slide or just in the tail. A dead trichomonad tends
to appear oval and slightly larger than a WBC.
Yeast Cells
Candida albicans and non–Candida spp. cause most fungal
infections but an occasional yeast in vaginal secretions is
considered part of the normal flora. Yeast cells appear on
3920_Ch15_269-282 23/01/14 10:41 AM Page 275
Chapter 15 | Vaginal Secretions
275
Figure 15–8 Trichomonas vaginalis. (From Leventhal
and Cheadle, Medical Parasitology, 6th edition, 2012, F.A.
Davis Company, Philadelphia, with permission.)
Figure 15–9 Trichomonas vaginalis in wet mount. (From Leventhal
and Cheadle, Medical Parasitology, 6th edition, 2012, F.A. Davis
Company, Philadelphia, with permission.)
a wet mount as both budding yeast cells (blastophores)
(Fig. 15–10) or as hyphae, which are long filaments that
grow and form a mycelium (Fig. 15–11). Pseudohyphae,
multiple buds that do not detach and form chains, can also
be seen. It can be difficult to distinguish yeast cells from
RBCs on a wet mount because both measure about 7 to
8 µm in diameter; however, differentiation can be made
using the KOH test. Yeast cells stain gram positive.
KOH Preparation and Amine Test
The KOH slide is prepared and the amine (Whiff) test is
performed by placing a drop of the saline specimen prepared
Figure 15–10 Budding yeast cells (×400).
from the collection swab onto a properly labeled clean slide
and adding one drop of 10% KOH solution. The slide is
immediately checked for a “fishy” amine odor. The result
is reported as positive (presence of fishy odor) or negative
(absence of fishy odor). Increased numbers of anaerobic bacteria in the vagina produce polyamines that are released into
the vaginal fluid. The odor results from the volatilization of
amines when the KOH is added. Because volatile amines are
not present in normal vaginal secretion, a positive test result
3920_Ch15_269-282 23/01/14 10:41 AM Page 276
276
Part Three | Other Body Fluids
PROCEDURE 15-3
KOH Preparation2
Figure 15–11 Yeast cells showing mycelial forms (×400).
suggests bacterial vaginosis caused by increased numbers of
G. vaginalis in conjunction with Mobiluncus spp. and with
T. vaginalis.
After the amine test has been performed, place a cover slip
over the specimen, taking care to exclude air bubbles. Allow
the KOH preparation to rest for 5 minutes to dissolve epithelial
and blood cells. Heat may be applied to speed the dissolving
process. One drop of 10% glycerin may be added after the
KOH to prevent specimen deterioration.2 The slide is examined under low power (100× magnification) for the presence
of yeast pseudohyphae and under high dry power (400× magnification) to identify smaller blastospores (yeast cells).2
Other Diagnostic Tests
Although the wet mount and KOH slide examinations and the
amine test are commonly used to diagnose bacterial vaginosis,
other tests may be required for a confirmatory diagnosis. These
include specimen culture, DNA probe testing, Gram stain,
proline aminopeptidase assay, and point of care test kits.
Gram Stain
The Gram stain is considered the gold standard in identifying
the causative organisms for bacterial vaginosis. It also provides
PROCEDURE 15-2
Saline Wet Mount2
1. Prepare a clean glass slide labeled with the patient’s
name and unique identifier.
2. Place one drop of vaginal specimen on the slide.
3. Cover the slide with a cover slip, removing any air
bubbles.
4. Examine the slide with the 10× objective for epithelial
cells and any budding yeast cells or pseudohyphae.
5. Examine the slide with the 40× objective and quantify
organisms and cells per hpf.
6. Record the results.
1. Prepare a clean glass slide labeled with the patient’s
name and unique identifier.
2. Place one drop of specimen on the slide.
3. Add one drop of 10% KOH to the slide.
4. Allow the KOH slide preparation to rest for up to
5 minutes to allow cellular tissue and other debris
to dissolve. Gentle heating may speed the dissolving
process.
5. Cover the specimen with a cover slip, removing any
air bubbles.
6. Examine the slide under the 10× objective for overall
assessment and for yeast pseudohyphae.
7. Switch to the 40× objective to examine for budding
yeast cells (smaller blastospores).
8. Record the results.
PROCEDURE 15-4
Amine (Whiff) Test
1. Apply one drop of the saline vaginal fluid suspension
to the surface of a clean glass slide.
2. Add one drop of 10% KOH directly to the vaginal
sample.
3. Holding the slide in one hand, gently fan above the
surface of the slide with the other hand and assess
for the presence of a fishy amine odor.
4. Report as positive or negative.
Positive: The presence of a fishy odor after adding
KOH.
Negative: The absence of a fishy odor after adding
KOH.
a permanent record of the patient specimen. A scored Gram
stain system is a weighted combination of the following morphotypes: Lactobacillus acidophilus (large gram-positive rods),
G. vaginalis and Bacteroides spp. (small gram-variable or gramnegative rods), and Mobiluncus spp. (curved gram-variable
rods). The types of bacterial morphophytes are evaluated
and scored. For example, lactobacillus morphophytes are the
predominant bacteria in normal vaginal flora; therefore, if
4+ lactobacillus morphophytes are present on Gram stain, and
Gardnerella and Bacteroides spp. morphophytes, and curved
gram-variable rods are absent, the score is 0. As indicated in
Table 15–4, a Nugent score of 0 to 3 is considered normal
vaginal flora, whereas a score of 4 to 6 is reported as intermediate, and a score of 7 or more is diagnostic of bacterial
vaginosis.
3920_Ch15_269-282 23/01/14 10:41 AM Page 277
Chapter 15 | Vaginal Secretions
Table 15–4
Lactobacillus
4+
3+
2+
1+
0
277
Nugent’s Gram Stain Criteria to Diagnose Bacterial Vaginosis
Gardnerella and Bacteroides
spp. Morphophytes
Curved Gram-Variable
Rods
0
1+
2+
3+
4+
0
1+ or 2+
3+ or 4+
Points
0
1
2
3
4
Note: Points are added according to the morphotypes seen. Add the points for all three columns for a final sum.
A score of 7 or higher indicates bacterial vaginosis.6
Culture
Culture, using various types of media, is the gold standard test
for detecting yeast and Trichomonas; however, it is more time
consuming and requires up to 2 days for a result. Culture for
G. vaginalis is not diagnostic for bacterial vaginosis because it
is part of the normal flora in 50% of healthy women.
Special media called Diamond’s medium is required for
T. vaginalis. A commercial transport and culture pouch system
for the detection of Trichomonas is now available (InPouch TV,
Biomed Diagnostics, White City, OR). The specimen must be
inoculated into the pouch within 30 minutes of collection and
then is incubated for 5 days at 37°C in a CO2 atmosphere.
The pouch is examined microscopically daily for motile
trichomonads.
DNA Testing
DNA hybridization probe methods have been developed to
specifically identify the causative pathogen for vaginitis. A DNA
probe testing system, Affirm VPIII (Becton, Dickinson, Franklin
Lakes, NJ), is available for differential diagnosis of G. vaginalis,
Candida spp., and T. vaginalis. It is easy to perform and results
are available in 1 hour with a sensitivity of 95%. This test is
significantly more sensitive than wet mount microscopy and
is less subjective to personnel bias compared with traditional
microscopic tests.
Trichomonas can also be detected by DNA probes amplified
by polymerase chain reaction (PCR). Enzymes are added to
the specimen that amplifies specific regions of T. vaginalis’ DNA
by PCR. The number of DNA fragments is then calculated. This
is the most accurate diagnostic method and it has the advantage of detecting nonviable organisms.9
Point of Care Tests
Various rapid diagnostic tests are available to quickly screen
for the causative agents of vaginitis and they provide a higher
sensitivity and specificity for the organism sought. For example, proline aminopeptidase activity in vaginal secretions can
be detected by rapid antigen tests to identify G. vaginalis.6
The OSOM Trichomonas Rapid Test (Genzyme Diagnostics,
Cambridge, MA) is an immunochromatographic strip test that
detects T. vaginalis antigen from vaginal swabs in 10 minutes.
The test is performed by placing the vaginal swab in the kit’s
sample buffer. The trichomonas proteins are solubilized into the
buffer. The test stick coated with anti-trichomonas antibodies is
placed into the sample mixture. The solution migrates up the
stick and if trichomonas antigens are present, they will react with
the antibodies on the stick. A visible blue line and a red internal
control line indicate a positive result.
The OSOM BVBLUE test (Genzyme Diagnostics, Cambridge,
MA) detects vaginal fluid sialidase, an enzyme produced by the
bacterial pathogens associated with bacterial vaginosis, such as
Gardnerella, Bacteroides, Prevotella, and Mobiluncus. The test takes
1 minute to perform and is read by examining the change in the
color of the solution: blue or green is positive, yellow is negative.
Commercial tests to measure an elevated vaginal pH
(VS-Sense Pro Swab) and the presence of amines (FemExam pH
and Amines TestCard, Litmus Concepts, Inc., Santa Clara, CA)
use pH indicators and an amine test system that is read visually
to identify bacterial vaginosis and trichomonas.
Vaginal Disorders
Bacterial Vaginosis
Bacterial vaginosis (BV) is the most common cause of vaginitis,
affecting 40% to 50% of women of childbearing age.1 BV occurs when there is an imbalance in the ratio of normal vaginal
bacterial flora. The predominant organism in the vaginal flora
is lactobacilli, which produce lactic acid that maintains the
vaginal pH between 3.8 and 4.5. Additionally, certain subsets
of lactobacilli produce hydrogen peroxide, which prevents
the overgrowth of normal vaginal flora. As the vaginal pH
becomes alkaline, lactobacilli are replaced by an overgrowth
of G. vaginalis, Mobiluncus spp., Prevotella spp., Porphyromonas,
Peptostreptococcus, Mycoplasma hominis, and Ureaplasma spp. The
malodor and increased abnormal vaginal discharge result from
this mix of organisms and is more apparent after intercourse.10
BV is associated with new or multiple sex partners, frequent douching, use of intrauterine devices, pregnancy, and a
lack of the protective lactobacilli.1 There is evidence that BV is
a risk factor for the premature rupture of membranes and
preterm labor for pregnant women. Additional complications
include pelvic inflammatory disease and endometritis as well
3920_Ch15_269-282 23/01/14 10:41 AM Page 278
278
Part Three | Other Body Fluids
as an increased risk for acquiring some sexually transmitted
infections (STIs) such as HIV, N. gonorrhoeae, C. trachomatis,
and HSV-2.1,5
BV is diagnosed by examining the vaginal secretions for
abnormal appearance or quantity, performing the pH and
amine tests, and microscopically observing the wet mount
for the presence of clue cells and the absence of WBCs and
lactobacilli morphotypes. According to Amsel’s Diagnostic
Criteria, three of the following four features must be present
for the diagnosis of BV: (1) thin, white, homogeneous discharge, (2) vaginal fluid pH greater than 4.5, (3) a positive
amine (Whiff) test, and (4) presence of clue cells on microscopic examination.5
The Gram stain is the gold standard for determining the
ratio of each bacterial morphotype and offers a definitive diagnosis. Other tests used to diagnose BV include the DNA
hybridization probe test, Affirm VPIII (Becton, Dickinson),
which detects G. vaginalis, a proline aminopeptidase test (Pip
Activity TestCard, Quidel, San Diego, CA), and the OSOM
BVBLUE test (Genzyme Diagnostics, Cambridge, MA).
Treatment is recommended for women to relieve vaginal
symptoms and reduce the risk of infection. In addition, benefits of treatment include reducing the risk of acquiring an STI
and reducing the risks associated with pregnancy. The recommended treatments are metronidazole (Flagyl), metronidazole
gel, or clindamycin cream.5
Trichomoniasis
Trichomoniasis is caused by the parasitic protozoon T. vaginalis.
The infection is transmitted by sexual intercourse and causes
vaginitis in women and sometimes urethritis in men. Most men
are asymptomatic carriers. The infection is classified as an STI,
frequently occurs with gonorrhea and Chlamydia infections,
and has been associated with enhanced transmission rates of
HIV.5,7,10 In pregnant women, a correlation has been found between a T. vaginalis infection and low birth weight, premature
rupture of membranes, and preterm delivery.10
Trichomoniasis is characterized by a green-to-yellow
frothy vaginal discharge, malodor, pruritus, irritation, dysuria,
dyspareunia, and vaginal mucosa erythema, although some
patients are asymptomatic. Patients may present with a “strawberry cervix” because of punctuate hemorrhages.10 Males are
usually asymptomatic or may present with urethritis.
Trichomoniasis can usually be diagnosed with the wet
mount examination and microscopically, visualizing the
motile trichomonads in a fresh specimen; however, this
method has a sensitivity of only 60% to 70%. 5 The test must
be performed within 2 hours of specimen collection to preserve the viability of the organism. WBCs and lactobacilli
bacteria also are present with a T. vaginalis infection. The
vaginal pH is greater than 4.5 and the amine test from the
KOH preparation will be positive.
If the wet mount is negative for motile trichomonads, a
culture using Diamond’s medium or the commercially available pouch system (InPouch TV, Biomed Diagnostics, White
City, OR) is recommended for detection of T. vaginalis. The
DNA probe test system, Affirm VPIII (Becton, Dickinson,
Franklin Lakes, NJ), and the point of care rapid antigen
detection test, OSOM Trichomonas Rapid Test (Genzyme
Diagnostics, Cambridge, MA), are available with increased
sensitivity and specificity for T. vaginalis.
The recommended treatment for trichomoniasis is
metronidazole. For patients who develop an allergy to metronidazole or for whom treatment is not effective, a newer drug,
tinidazole, is available. All sexual partners of patients, even if
asymptomatic, should be treated to avoid reinfection.
Candidiasis
Vulvovaginal candidiasis is caused by an infection with the
yeast Candida. It is a common cause of vaginitis, and nearly
75% of adult women have at least one yeast infection in their
lifetime.10 Most yeast infections are caused by C. albicans,
but other nonalbican species such as C. glabrata, C. parapsilosis, C. tropicalis, and C. krusei have been isolated as the
cause.
Candida is part of the normal vaginal flora and an infection
occurs when there is a change in the vaginal environment that
permits the overgrowth of Candida and symptoms of the infection to occur. Conditions that can cause a change in the vaginal
environment include the use of broad-spectrum antibiotics,
oral contraceptives, or estrogen replacement therapy; hormonal
changes that occur with pregnancy; ovulation; and menopause.
Increased infection rates occur in immunocompromised patients and with conditions such as diabetes mellitus, iron deficiency, and HIV infection. The infection is predominantly
found in women of childbearing age, who are producing large
amounts of estrogen. Estrogen causes the vagina to mature and
produce glycogen, which facilitates the growth and adherence
of C. albicans.10
Typical clinical symptoms of vulvovaginal candidiasis include genital itching or burning, dyspareunia, dysuria, and the
presence of an abnormal thick, white, curd-like vaginal discharge. The pH of the vaginal fluid remains normal (3.8 to 4.5)
and the amine test is negative. In vulvovaginal candidiasis, the
microscopic examination of the saline and KOH wet prep and
Gram stain will reveal budding yeast and pseudohyphae forms,
large numbers of WBCs, lactobacilli, and large clumps of epithelial cells. A culture and DNA hybridization probe (Affirm
VPIII Microbial Identification System; Becton, Dickinson)
analysis can be performed to confirm the clinical diagnosis and
to identify the species of Candida.
Yeast infections are treated with over-the-counter or prescription azole antifungal agents. They may be intravaginal,
suppository, or oral agents, and the regimen depends on the
medication. Over-the-counter intravaginal medications include
butoconazole, clotrimazole, tioconazole, and miconazole. For
patients with recurrent infections (four or more episodes per
year), a prescription medication using a longer treatment regimen with either oral fluconazole or intravaginal butoconazole,
nystatin, and terconazole may be more effective.5 Vulvovaginal
candidiasis is not acquired through sexual intercourse, so treatment of sexual partners is not indicated.
3920_Ch15_269-282 23/01/14 10:41 AM Page 279
Chapter 15 | Vaginal Secretions
Desquamative Inflammatory Vaginitis
Desquamative inflammatory vaginitis (DIV) is a syndrome
characterized by profuse purulent vaginal discharge, vaginal
erythema, and dyspareunia.3 There is a heterogeneous group
of causes of DIV; however, β -hemolytic gram-positive streptococci can be cultured from most patients.3 The syndrome also
can occur secondary to atrophic vaginitis in postmenopausal
women as a result of decreased estrogen. The vaginal secretion
pH is greater than 4.5 and the amine test is negative.
Wet mount and Gram stain microscopic examination of
the vaginal secretions reveal large numbers of WBCs, RBCs,
occasional parabasal and basal cells, squamous epithelial cells,
and reduced or absent lactobacilli that have been replaced by
gram-positive cocci (see Table 15–1).
DIV is treated with 2% clindamycin.3 Hormone replacement therapy is effective for patients with DIV secondary to
atrophic vaginitis.
Atrophic Vaginitis
Atrophic vaginitis is a syndrome found in postmenopausal
women. This syndrome is caused by thinning of the vaginal
mucosa because of reduced estrogen production and decreased
glycogen production. As a result, the vaginal environment
changes and the balance of normal flora is altered. Clinical symptoms include vaginal dryness and soreness, dyspareunia, inflamed
vaginal mucosa, and purulent discharge. The vaginal secretion
pH is greater than 4.5 and the amine test is negative.
Microscopic evaluation is similar to that for DIV and includes large numbers of WBCs and the presence of RBCs, occasional parabasal and basal cells, squamous epithelial cells,
and decreased numbers of lactobacilli that have been replaced
by gram-positive cocci and gram-negative rods.3
Treatment of atrophic vaginitis is estrogen replacement.
Topical vaginal ointments are initially used; however, for frequent recurrent episodes of atrophic vaginitis, oral or transcutaneous (patch) modes are more effective.
Additional Vaginal Secretion
Procedures
As noted previously in this chapter, complications from
vaginitis syndromes can include premature rupture of fetal
membranes and a high risk of preterm labor. The fetal
fibronectin enzyme test and the AmniSure (AmniSure International, LLC) test to detect the amniotic fluid protein PAMG-1
are tests to evaluate these conditions. The fern test described
in Chapter 13 is another test that determines the presence of
amniotic fluid in vaginal secretions. Patient history, a vaginal
pH greater than 7.0, and a positive fern test are strong indicators of amniotic sac rupture.
Fetal Fibronectin Test
Preterm delivery, defined as delivery before the completion of
37 weeks’ gestation, is the leading cause of neonatal mortality
279
and morbidity in the United States.11 Fetal fibronectin (fFN)
is an adhesive glycoprotein in the extracellular matrix at the
maternal and fetal interface within the uterus. It is elevated
during the first 24 weeks of pregnancy but then diminishes.
The presence of fetal fibronectin in vaginal secretions between
24 and 34 weeks’ gestation is associated with preterm delivery.
The test can be used by health-care providers as a means to
better manage patient care and can be performed routinely as
part of a prenatal visit for asymptomatic women between 22
and 30 weeks’ gestation or in symptomatic pregnant women
between 24 and 34 weeks. Symptoms of preterm delivery include a change in vaginal secretions, vaginal bleeding, uterine
contractions, abdominal or back discomfort, pelvic pressure,
and cramping.
The specimen is obtained by rotating the swab provided
in the specimen collection kit across the posterior fornix of the
vagina for 10 seconds to absorb the vaginal secretions. The
swab must not be contaminated with lubricants, creams, soaps,
or disinfectants that may interfere with the antibody-antigen
reaction in the test system.
The methods for detection of the fetal fibronectin enzyme
immunoassay are solid-phase enzyme-linked immunosorbent
assay (ELISA) or lateral flow, solid-phase immunochromatographic assay using the Rapid fFN cassette. In the fFN enzyme
immunoassay, the vaginal sample is incubated with FDC-6, a
monoclonal antibody specific for fFN, and the presence or absence of the fFN is determined spectrophotometrically at a
wavelength of 550 nm.
The rapid fFN assay is a qualitative test for the detection
of fFN that uses a Rapid fFN cassette kit and a TLiIQ analyzer.
The specimen swab is placed into an extraction buffer and filtered with a plunger filter. The filtered sample is dispensed
onto the sample application well of the Rapid fFN cassette. The
sample flows from an absorbent pad across a nitrocellulose
membrane by capillary action through a reaction zone containing murine monoclonal anti-fFN antibody conjugated to blue
microspheres. The monoclonal antibody FDC-6 is specific for
fFN. The conjugate, embedded in the membrane, is mobilized
by the flow of the sample. The sample then flows through
a zone containing goat polyclonal anti-human fibronectin
antibody that captures the fibronectin-conjugate complexes.
The remaining sample flows through a zone containing goat
polyclonal anti-mouse IgG antibodies, which captures unbound conjugate, resulting in a control line. After 20 minutes,
the intensities of the test line and control line are interpreted
with the TLiIQ analyzer. The results are reported as positive or
negative.12 Symptomatic pregnant women with a positive fFN
test are at increased risk for delivery in less than or equal to
7 to 14 days from specimen collection and asymptomatic pregnant women are at increased risk for delivery in less than or
equal to 34 weeks and 6 days of gestation.12
AmniSure Test
The risk of premature delivery also may be caused by the rupture
of fetal membranes. In addition, rupture of fetal membranes can
cause infection, fetal distress, prolapse of the umbilical cord,
3920_Ch15_269-282 23/01/14 10:41 AM Page 280
280
Part Three | Other Body Fluids
postnatal endometritis, and placental abruption. A symptom of
fetal membrane rupture is leakage of amniotic fluid. PAMG-1 is
present in high levels in amniotic fluid and low levels in blood;
therefore, it is a reliable marker of fetal membrane rupture. A
normal level of PAMG-1 in pregnant women ranges from 0.05
to 0.22 mg/mL, which might increase to 3 mg/mL when vaginitis
is present. Fetal membrane rupture causes increased concentrations of amniotic fluid in the vaginal secretions and can raise the
PAMG-1 levels to 2,000 to 25,000 mg/mL.13
The AmniSure ROM test (AmniSure International, LLC)
is a qualitative rapid test that uses an immunochromatographic device. A sample of vaginal secretions collected with
a swab is placed into a vial with solvent. The swab is rotated
for 1 minute to enable the solvent to extract the sample from
the swab and then discarded. The AmniSure test strip is
placed into the vial. Monoclonal antibodies with colloidal
gold particles attached are located on the pad region of the
test strip. The antibodies attach to the PAMG-1 in the sample
and transport it to the test region. The solution flows from
the pad region of the strip to the test region. The test region
of the test strip has antibodies immobilized on it. If PAMG-1
is present in the patient sample, it will bind with antibodies
in the test region, producing a line in the test region. This line
is produced by gold dye attached to conjugated antibodies
and indicates a rupture of fetal membranes. The second control line is designed to indicate that the test is functioning well.
The test is read immediately or within 10 minutes. A positive
test result indicates a membrane rupture and is indicated by
the presence of two lines. When only the control line is present, it is reported as negative for membrane rupture. The test
should be performed immediately after collection, but if there
is a delay in testing, the specimen can be maintained in a
closed sample vial and refrigerated for 6 hours.
The AmniSure test quickly identifies patients with fetal
membrane rupture, and appropriate intervention can take
place.
Log on to
www.fadavis.com/strasinger
for additional content related
to this chapter.
References
1. Egan, MA, and Lipsky, MS: Diagnosis of vaginitis, Am Fam
Physician 62(5):1095–1104, Sep 2000. Web site: http://
www.aafp.org/afp/2000/0901/p1095.html
2. Clinical and Laboratory Standards Institute. Provider-Performed
Microscopy Testing: Approved Guideline, ed. 2. CLSI document
POCT10-A2. CLSI, Wayne, PA, 2011.
3. Metzger, GD: Laboratory diagnosis of vaginal infections. Clin
Lab Sci 11:47–52, 1998.
4. Woods, GL, and Croft, AC: Specimen collection and handling
for diagnosis of infectious diseases. In Henry, JB (ed): Clinical
Diagnosis and Management by Laboratory Methods, ed 22.
Elsevier Saunders, Philadelphia, 2011.
5. Centers for Disease Control and Prevention: Diseases characterized by vaginal discharge. Sexually Transmitted Diseases
Treatment Guidelines, 2010. http://www.cdc.gov/std/
treatment/2010/vaginal-discharge.htm
6. French, L, Horton, J, and Matousek, M: Abnormal vaginal
discharge: Using office diagnostic testing more effectively,
J Fam Practice 53(10): Oct 2004. Web site: http://www.
jfponline.com/Pages.asp?AID=1788
7. Fader, RC: Anaerobes of clinical importance. In Mahon, CR,
Lehman, DC, and Maneselis, G: Textbook of Diagnostic
Microbiology, ed 4. Saunders Elsevier, Maryland Heights,
MO, 2011.
8. Smith, LA: Diagnostic Parasitology. In Mahon, CR, Lehman,
DC, Maneselis, and Maneselis, G: Textbook of Diagnostic
Microbiology, ed 4. Saunders Elsevier, Maryland Heights,
MO, 2011.
9. Patil, MJ, Magamoti, JM, and Metgud, SC: Diagnosis of
Trichomonas vaginalis from vaginal specimens by wet mount
microscopy, in pouch TV culture system, and PCR. J. Global
Infect Dis [serial online] [cited 2012 Jul 6] 4:22–25, 2012.
Web site: http://www.jgid.org/text.asp?2012/4/1/22/ 93756
10. Keen, EF, and Aldous, WK: Genial infections and sexually
transmitted diseases. In Mahon, CR, Lehman, DC, Maneselis,
G: Textbook of Diagnostic Microbiology, ed 4, Saunders
Elsevier, Maryland Heights, MO, 2011.
11. Lockwood, CJ, Senyei, AE, Dische, MR, Casal, DC, et al: Fetal
fibronectin in cervical and vaginal secretions as a predictor of
preterm delivery. New Engl J Med 325:669–674, 1991.
12. Fetal Fibronectin Enzyme Immunoassay and Rapid fFN for
the TLiIQ System. AW-04196-002 Rev.002, Hologic, Inc. Web
site: http://www.ffntest.com/;hcp/science_fetal.html
13. Cousins, LM, et al: AmniSure Placental Alpha Microglobulin-1
Rapid Immunoassay versus standard diagnostic methods for
detection of rupture of membranes. Am J Perinatol 22(6):
317–320, Aug 2005.
3920_Ch15_269-282 23/01/14 10:42 AM Page 281
Chapter 15 | Vaginal Secretions
281
Study Questions
1. Which of the following would not be a reason to collect a
vaginal fluid for analysis?
A. Vaginitis
B. Complications of pregnancy resulting in preterm
delivery
C. Forensic testing in a sexual assault
D. Pregnancy testing
2. Which of the following organisms might not be detected
if the specimen for vaginal secretion analysis had been
refrigerated?
A. Prevotella bivia
B. Lactobacillus acidophilus
C. Trichomonas vaginalis
D. Candida albicans
3. The appearance of the vaginal discharge in vulvovaginal
candidiasis is described as:
A. Clear and colorless
B. Thin, homogeneous white-to-gray discharge
C. White, curd-like
D. Yellow-green and frothy
4. A normal range for a vaginal pH is:
A. 3.8 to 4.5
B. 5.0 to 6.0
C. 6.0 to 7.0
D. 7.0 to 7.4
5. Which of the following tests differentiates budding yeast
cells from RBCs?
A. pH
B. Saline wet mount
C. KOH prep
D. Whiff test
6. Which of the following constituents is normal in healthy
vaginal fluid secretions?
A. Lactobacilli
B. Basal cells
C. Trichomonas vaginalis
D. Pseudohyphae
7. Vaginal specimens collected for a saline wet prep should be:
A. Refrigerated to preserve motility
B. Prepared as soon as possible
C. Mailed to a reference laboratory
D. Preserved with potassium hydroxide
8. A positive amine (Whiff) test is observed in which of the
following syndromes?
A. Bacterial vaginosis
B. Vulvovaginal candidiasis
C. Atrophic vaginitis
D. Desquamative inflammatory vaginitis
9. A squamous epithelial cell covered with coccobacilli that
extends beyond the cytoplasm margin is a:
A. Basal cell
B. Parabasal cell
C. Clue cell
d. Blastospore
10. All of the following are diagnostic of bacterial vaginosis
except:
A. Vaginal pH of 3.8
B. Presence of clue cells
C. Positive amine (Whiff) test
D. Thin, homogeneous white-to-gray vaginal
discharge
11. Which of the following organisms produces lactic acid
and hydrogen peroxide to maintain an acid vaginal
environment?
A. Gardnerella vaginalis
B. Mobiluncus spp.
C. Lactobacilli spp.
D. β -Hemolytic streptococci
12. All of the following are diagnostic of vulvovaginal candidiasis except:
A. Large numbers of WBCs
B. Presence of clue cells
C. Positive KOH test
D. Vaginal pH of 4.0
13. All of the following are diagnostic of trichomoniasis
except:
A. Vaginal pH of 6.0
B. Positive amine test
C. Positive KOH test
D. Motile trichomonads present
3920_Ch15_269-282 23/01/14 10:42 AM Page 282
282
Part Three | Other Body Fluids
14. The bacteria associated with desquamative inflammatory
vaginitis is:
A. β -Hemolytic streptococci
B. Trichomonas vaginalis
C. Gardnerella vaginalis
D. Mycoplasma hominis
15. The protein present in vaginal secretions that can identify
patients who are at risk for preterm delivery is:
A. Human chorionic gonadotropin
B. Estrogen
C. PAMG-1
D. Fetal fibronectin
Case Studies and Clinical Situations
1. A 30-year-old woman has symptoms of dysuria, vaginal
itching, and a white, curd-like discharge. During her
visit at the Women’s Clinic, the patient revealed that she
had recently completed a regimen of broad-spectrum
antibiotics as treatment for a urinary tract infection. Her
health-care provider takes a swab of the vaginal secretions
for analysis.
a. What tests will be performed on the vaginal specimen?
b. Based on the patient history and observation of the
vaginal secretion, which test will be diagnostic for the
probable diagnosis?
c. What confirmatory test can be performed?
d. What is the probable diagnosis?
e. What is the first choice of treatment?
2. A sexually active teenager visited the Women’s Clinic complaining of vaginal itching and soreness. She indicated that
she was experiencing increased vaginal secretions that were
frothy and yellow to green. Upon examination, the healthcare provider noted a strawberry-like cervix and performed
a pH test on the secretions. The pH was 5.5 and the wet
prep demonstrated “swimming” organisms.
a. What is the probable diagnosis?
b. What other tests can be performed to confirm this
diagnosis?
c. What is the best course of treatment?
d. Should her sexual partner be treated?
e. List three complications that can occur with this
disorder.
3. During a routine visit with the gynecologist, a 60-year-old
woman complained of vaginal dryness and soreness. During
the examination, the health-care provider noted erythema
of the vaginal mucosa. The pH of the vaginal secretions
was 6.0. The KOH and amine (Whiff) tests were negative.
The microscopic examination revealed epithelial cells, basal
cells, decreased lactobacilli, and increased gram-positive
cocci and gram-negative rods.
a. What is the name of this condition?
b. Explain how this condition can occur.
c. What is the treatment for this condition?
3920_App A_283-292 23/01/14 9:16 AM Page 283
APPENDIX
A
Urine and Body Fluid Analysis
Automation
Urinalysis Automation
Studies have shown that the major variable in urinalysis testing
is the conscientiousness of the laboratory personnel in their
timing and interpretations of the color reactions. Correct color
readings depend on the accuracy of the timing. The ultimate
goal of urinalysis automation is to improve reproducibility and
color discrimination while increasing productivity and standardization for reporting urinalysis results.
Subjectivity associated with visual discrimination among
colors has been alleviated by the development of automated
reagent strip readers that use a spectrophotometric measurement of light reflection termed “reflectance photometry.” Reflectance photometry uses the principle that light reflection
from the test pads decreases in proportion to the intensity of
color produced by the concentration of the test substance. In
reflectance photometry, a monochromatic light source is directed toward the reagent pads by placing a filter between the
light source and the reflective surface of the pad or by using a
light-emitting diode (LED) to provide the specific wavelength
needed for each test pad color reaction. The light is reflected
to a photodetector and an analog or digital converter. The instruments compare the amount of light reflection with that of
known concentrations, then display or print concentration
units or transmit data to a laboratory information system (LIS).
Several automated instruments are available that standardize sample processing, analyze test strips, perform urine sediment analysis, and report results with consistent quality and
reduced hands-on time. The instruments are user-friendly and
include visual and audio prompts for operation. The various
manufacturers’ instruments include different features and
principles for testing. See Table A–1 for a breakdown of
measurement technology used by the major urine analyzer
manufacturers.
Table A–1
Additional advantages to automation include online
computer capability with LIS interface; bar coding; manual
entry of color, clarity, and microscopic results to be included
on the printed report; flagging abnormal results; storing patient and control results; and minimal calibration, cleaning,
and maintenance.
Automated instruments in urinalysis include semiautomated and fully automated chemistry analyzers, automated urine cell analyzers, and completely automated systems.
Semi-automated instruments still depend on an operator for
specimen mixing, test strip dipping, and microscopic results
input. In a fully automated chemistry analyzer, the tubes of
urine are placed on a rack or a carousel and moved automatically through the instrument. Automated urine cell analyzers
mix, aspirate, dilute, and stain urine to classify urine sediment
particles. Automated urine systems perform a complete urinalysis that includes the physical, chemical, and microscopic parts
of a routine urinalysis. The automated urinalysis instruments
currently available are listed in Table A–2; however, new instruments are continually being developed.
Semi-Automated Urine Chemistry
Analyzers
Semi-automated urine analyzers test for the chemical components of urine. The instruments read and interpret the reagent
strip results consistently, thereby standardizing the interpretation of reagent strip results and eliminating personnel color
bias and timing discrepancies. Depending on the instrument
and the reagent strip used, the following tests can be performed: leukocyte, nitrite, protein, blood, glucose, ketone,
bilirubin, urobilinogen, pH, specific gravity, color, creatinine,
and protein-to-creatinine ratio. Semi-automated analyzers are
well suited for small- and medium-volume laboratories and
Measurement Technology Methods in Automated Urinalysis
Urine Measurement Technology
Manufacturer
Color
Clarity
Specific Gravity
ARKRAY, Inc
Iris Diagnostics
Roche Diagnostics
Siemens Healthcare
Diagnostics, Inc.
Photometry
Light transmission/light scatter
Reflectance photometry
Reflectance photometry
Light scatter
Light transmission/light scatter
Turbidity
Light transmission/light scatter
Refractive index
Refractive index
Refractometry
Refractive index
283
3920_App A_283-292 23/01/14 9:16 AM Page 284
284
Appendix A | Urine and Body Fluid Analysis Automation
Table A–2
Urinalysis Automation
Equipment
Manufacturer
Semiautomated Chemistry Instruments
Clinitek Advantus
Siemens Healthcare Diagnostic, Inc.
Clinitek Status
Siemens Healthcare Diagnostics, Inc.
Urisys 1800 system
Roche Diagnostics
COBAS u411
Roche Diagnostics
DiaScreen 50
U. S. ARKRAY
iChem 100
Iris Diagnostics
Fully Automated Chemistry Instruments
Clinitek Atlas
Siemens Healthcare Diagnostic, Inc.
Urisys 2400 system
Roche Diagnostics
Aution Max AX-4030 U. S. ARKRAY
IChem Velocity
Iris Diagnostics
Automated Microscopy
UF-1000i Urine
Sysmex Corporation
Cell Analyzer
iQ 200 Automated
Iris Diagnostics
Urine Microscopy
Urine Analyzer (iQ
Iris Diagnostics
200 Sprint)
Automated Urinalysis Systems
iRICELL Urinalysis
Iris Diagnostics
Systems
(iRICELL 3000plus, iRICELL 2000plus, iRICELL 3000pro,
iRICELL 2000pro, iRICELL 1500)
CLINITEK AUWi
Siemens Healthcare Diagnostics, Inc
System
and specimen color and clarity may be entered manually or a
barcode reader can be used to identify samples. Positive results
are flagged to indicate a patient sample that requires additional
confirmation testing or microscopic evaluation.
The semi-automated instrument requires the operator to:
1. Dip the reagent strip into a well-mixed urine sample.
2. Blot the strip to remove excess urine.
3. Place the strip onto the reagent strip platform.
4. Press the analyze/enter button.
Results are printed out, and abnormal results are flagged
automatically. As the strip moves through the instrument, reflectance readings are taken at the correct time intervals. Some
manufacturers’ test strips have a color compensation pad that
adjusts results for urine color. This feature allows the instrument to subtract the urine color from the color developed on
the reaction pad, providing an accurate result for each pad despite the interference. The strips are then moved to the waste
container. Results are stored in the analyzer, printed, or sent
to the LIS. Examples of semi-automated instruments are shown
in Figures A–1 through A–6.
Daily maintenance is minimal and includes cleaning the
reagent strip platform and emptying the reagent strip waste
container.
Fully Automated Urine Chemistry
Analyzers
Fully automated instruments are designed for a high-volume
urinalysis laboratory with user walk-away capability. The various
instruments have the ability to load many samples on a carousel
or rack at one time with the capability to insert a STAT specimen
during the run. The start or analyze button is pressed to begin
testing and the specimen automatically moves through the instrument. The specimen is identified. A sample probe aspirates
Body Fluid Analyzers
ADVIA2120i with
Body Fluids
Software
Sysmex XE-5000
using Body Fluids
mode
iQ 200 using Body
Fluids Software
Siemens Healthcare Diagnostics, Inc.
Sysmex Corporation
Iris Diagnostics
physicians’ offices, and meet the Clinical Laboratory Improvement Amendments (CLIA)-waived standards.
Semi-automated analyzers are self-calibrating and some instruments perform automatic checks (Auto-Checks) to identify
strip type and humidity exposure. For a semi-automated instrument, the reagent strips are manually dipped and placed on the
strip reader, the reaction pads are read at the correct time, and
the strip is moved to the waste container. The results are displayed, printed, or transmitted to an LIS. Patient identification
Figure A–1 DiaScreen50 semi-automated urine chemistry analyzer.
(Image courtesy of U. S. ARKRAY.)
3920_App A_283-292 23/01/14 9:16 AM Page 285
Appendix A | Urine and Body Fluid Analysis Automation 285
A
Figure A–2 Cobas u 411 urine chemistry analyzer. (Image courtesy
of Roche Diagnostics.)
B
Figure A–4 Clintek Status + Analyzer. A, Clinitek Status Connect with
Barcode Stand. B, Clinitek Status with test strip. (Images courtesy of
Siemens Healthcare Diagnostics Inc.)
Figure A–3 Urisys 1100 semi-automated urine chemistry analyzer.
(Image courtesy of Roche Diagnostics.)
Figure A–5 Clinitek Advantus semi-automated urine chemistry analyzer. (Image courtesy of Siemens Healthcare Diagnostics Inc.)
3920_App A_283-292 23/01/14 9:17 AM Page 286
286
Appendix A | Urine and Body Fluid Analysis Automation
Figure A–6 iChem 100 semi-automated urine chemistry analyzer.
(Image courtesy of Iris Diagnostics.)
an exact amount of urine sample and dispenses it directly onto
the reagent strip. The reagent strip advances automatically to the
reflectance photometer to measure the color change of each
reagent pad. The strip then advances automatically to the disposal
area. Tests are measured by the dry pad test using reflectance photometry to detect color change, and taking readings at the appropriate time and wavelength for each specific test. Analytes
measured vary by the instrument and may include leukocytes,
ketones, protein, glucose, nitrite, blood, urobilinogen, pH, bilirubin, color, clarity, creatinine, and protein-low. Color is measured
by either reflectance photometry or spectrophotometry at multiple wavelengths. Specific gravity is measured by refractive index
methodology, and clarity is a measurement of transmitted or scattered light. The instruments use integrated bar-coded sample
identification and allow abnormal ranges to be selected so that
samples that require microscopic examination or confirmatory
testing can be identified and flagged. Patient results and quality
control results and calibrations are stored for visual display, printout, or transmission to a laboratory computer system. Standardized controls are run as set by laboratory protocol. Examples of
fully automated urine chemistry analyzers are shown in
Figures A–7 through A–10.
Figure A–7 Urisys 2400 automated urine chemistry analyzer. (Image
courtesy of Roche Diagnostics.)
Automated Microscopy
In a routine urinalysis, a test strip determines the chemical analytes, and the formed elements are determined by microscopy.
Manual microscopy is not easily standardized because of the
high variation among operators even in the same institution.
Routine specimen processing such as centrifugation can affect
accuracy because rare elements such as casts or cells may be lost
during handling. It has been demonstrated that recovery of
formed elements in the sediment after centrifugation is highly
variable. Results are not quantitative because they must be reported in ranges or averages. Overall, manual microscopy is not
cost effective because of the labor and time required to process
and analyze the specimen, which ultimately reduces turnaround
times for results. Automated urine cell analyzers provide efficient
standardized results in less than 1 minute as compared with
Figure A–8 Clinitek Atlas automated urine chemistry analyzer. (Image
courtesy of Siemens Healthcare Diagnostics Inc.)
approximately 6 minutes using the manual method, markedly
improving turnaround times. Two automated urine cell analyzers
are currently available in the United States: the Sysmex UF-1000i
and the iQ 200 from Iris Diagnostics.
Sysmex UF-1000i
The Sysmex UF-1000i (Sysmex Corporation, Kobe, Japan) uses
laser-based flow cytometry that measures forward light scatter,
side scatter, fluorescence staining characteristics, and adaptive
3920_App A_283-292 23/01/14 9:17 AM Page 287
Appendix A | Urine and Body Fluid Analysis Automation 287
cells (WBCs), epithelial cells, hyaline casts, and bacteria. The
results are displayed as scattergrams (Fig. A–15). These parameters are directly reportable without technologist intervention
and may be autovalidated. Flagged particles include pathologic
casts, crystals, small round cells (renal tubular epithelial cells
or transitional epithelial cells), sperm, mucus, and yeast-like
cells, and must be confirmed by manual microscopy. A latex
particle quality control system monitors performance, and
quality control records can be viewed on the instrument screen
in a Levy-Jennings graph. The analyzers can store up to 10,000
patient results, including scattergrams, histograms, and specimen characteristics, which can be saved and viewed by the
user. A bidirectional interface is provided to download and
report results. The UF-1000i can be used independently or
integrated with an automated urine chemistry strip reader to
create a complete urinalysis system.
Figure A–9 Aution Max AX-4030 fully automated urine chemistry
analyzer. (Image courtesy of U. S. ARKRAY.)
Figure A–10 iChem Velocity automated urine chemistry analyzer.
(Image courtesy of Iris Diagnostics.)
cluster analysis to identify stained urine sediment particles
(Fig. A–11). To perform an automated microscopy, 4 mL of uncentrifuged urine is aspirated into the instrument and divided
into two channels: one for urine particle analysis and one for
bacteria staining and detection (Fig. A–12). Each channel has
a specific stain that targets the internal components of the cells.
The stained urine sample passes through the flow cell, where
it is hydrodynamically focused and presented to a red semiconductor laser (635 nm) (Fig. A–13). Particles are identified
by measuring the height and width of the fluorescent and light
scatter signals, which are presented in scattergrams and histograms. In the bacterial channel, the diluent stabilizes the pH
and lyses the nonbacterial particles, eliminating amorphous
crystals. The stain is specific to the RNA in a bacterial cell, eliminating any nonspecific staining of debris. The width of the fluorescent signal measures cellular inclusions and the width of
forward light scatter measures the length of cells (Fig. A–14).
Resulting values are presented in quantitative cells per microliter and cells per high- or low-powered field. Thresholds to
be flagged for primary elements can be established and abnormal results are flagged for confirmatory review. The main
particles enumerated are red blood cells (RBCs), white blood
Figure A–11 Sysmex UF 1000i urine chemistry analyzer. (Image courtesy of Sysmex Corporation, Mundelein, IL.)
Forward scatter
signal amplifier
Fluorescence
signal amplifier
Red semiconductor
laser
Sheath reagent
Side scatter
signal amplifier
Conductivity sensor
Dilution and staining
for bacteria analysis
Dilution and staining
for sediment analysis
Urine sample
Flow cytometry
Figure A–12 Diagram of urine particle analysis in the Sysmex UF1000i.
3920_App A_283-292 23/01/14 9:17 AM Page 289
Appendix A | Urine and Body Fluid Analysis Automation 289
Figure A–18 Auto-Particle Recognition (APR) process. (Image courtesy of Iris Diagnostics.)
Figure A–15 Scattergram showing Sysmex UF1000i microscopy results.
Figure A–19 iQ 200 urinalysis results display, showing particle categories available for analysis or counting. (Image courtesy of Iris
Diagnostics.)
Figure A–16 iQ 200 microscopy analyzer. (Image courtesy of Iris
Diagnostics.)
The sedMAX (77Elektronika, distributed in Europe and
Asia by A. Menarini Diagnostics) performs automated microscopy with digital imaging. The instrument uses newer
technology, and as of this writing is not yet FDA approved for
use in the United States. The sedMAX requires a minimum of
2 mL of urine that is centrifuged in a special cuvette to produce
a monolayer of urine sediment. The sediment is analyzed by a
bright-field microscope and digital camera to capture and categorize 15 particle images based upon size and shape using
image-processing software.2 An advantage to this instrument
is the zoom capability to view images and interpretation of the
images is similar to manual microscopic smears.
Automated Urinalysis Systems
Figure A–17 Diagram of the iQ 200 digital flow capture process.
(Image courtesy of Iris Diagnostics.)
reviewed easily and reclassified by the operator without the
need for manual microscopy.
The software allows the user to subclassify 27 additional categories to indicate the specific types of crystals, casts, epithelial
cells, yeast with pseudohyphae, trichomonads, and oval fat
bodies. Free text comments can be added to the report as needed.
Combining automated urine chemistry analyzers and automated urine cell analyzers to create completely automated urinalysis systems has significantly improved turnaround times
for urinalysis. Technologists’ hands-on time has been significantly reduced as well. Using similar sample racks and moving
on a conveyor system, samples are easily transferred from one
instrument to the next, providing a complete walkaway capability with minimal specimen handling from sampling through
results. By interfacing with the LIS, bar-coded samples are automatically identified and processed according to the requested
tests. The systems can independently perform both physical
and chemical testing, microscopy analysis, and a combination
of both. A complete urinalysis report can be sent directly to
the LIS or printed out, thereby reducing clerical error.
The Clinitek Atlas (Siemens Healthcare Diagnostics,
Deerfield, IL), an automated urine chemistry analyzer, and the
3920_App A_283-292 23/01/14 9:17 AM Page 290
290
Appendix A | Urine and Body Fluid Analysis Automation
Sysmex UF-1000i (Sysmex Corporation, Mundelein, IL), an
automated urine cell analyzer, have been integrated to
develop the CLINITEK AUWi System (Siemens), which performs a completely automated urinalysis (Fig. A–20). A minimum of 5 mL of urine is required in the automated mode.
The bar-coded tubes are racked and placed onto the system.
The rack advances to the ATLAS analyzer, where the specimen is identified, mixed, aspirated, and tested for physical
and chemical components. The sample then travels across a
connecting bridge to the UF-1000i for microscopic analysis.
The instrument automatically reflexes samples requiring
sediment analysis, reducing the time associated with manual
microscopic analysis. Results are automatically verified and
integrated into a complete urinalysis report to be sent to the
LIS or printed.
The iRICELL Automated Urinalysis Systems (Iris Diagnostics) consist of the iChem VELOCITY urine chemistry analyzer and the iQ 200 (Fig. A–21). A minimum of 4 mL of
urine is required. The bar-coded tubes are placed into the
10-position rack and are moved to the iChem VELOCITY,
where the sample is mixed and the urine is aspirated. Upon
completion of the physical and chemical analysis, the
rack moves across the connecting bridge to the iQ 200 for
microscopy testing. Samples can be reflexed to urine
microscopy based upon urine chemistry results. One hundred percent microscopy is not required with iRICELL.
Results for a complete urinalysis are transmitted to the LIS
or printed.
Figure A–20 AUWi, a fully automated urinalysis system that combines
the Siemens Clinitek Atlas Chemistry analyzer and the Sysmex
UF-1000i particle analyzer. (Image courtesy of Siemens Healthcare
Diagnostics Inc.)
Figure A–21 iRICELL3000, a fully automated Urinalysis System that
combines the iChem Velocity urine chemistry analyzer and the iQ 200
microscopy analyzer. (Image courtesy of Iris Diagnostics.)
Body Fluid Analysis
Automation
Body fluid cell counts and differentials are traditionally performed manually using a Neubauer hemocytometer. These are
labor-intensive and time-consuming procedures subject to
technologist variability. Automation brings quality control and
precision to a method that previously was uncontrolled. Automated instruments have not, however, completely eliminated
the use of a manual hemacytometer count. Body fluids with
low cell counts or malignant cells still require a manual differential using a stained cytospin smear. The laboratory must define the limits for the instrument and establish the lower limits
for cell counting to determine when a manual procedure must
be performed.2 For example, the iQ 200 is linear down to zero
(0 to 10,000 cells/L). Linearity can be extended during method
comparison. In addition, the laboratory must follow manufacturers’ recommended procedures for special treatment required
for the specific body fluid analyzed.3
Hematology analyzers that are used to perform body fluids
cell counts include the ADVIA2120i (Siemens) the Sysmex XE
5000 (Sysmex) and the Beckman Coulter LH780 and UniCel
DxH800 (Beckman Coulter, Inc.). The ADVIA 2120i uses flow
cytometry, light scatter, and absorbance to count red and white
blood cells, and perform a WBC differential that includes percentages and absolute numbers of mononuclear cells and polymorphonuclear cells on samples with greater than 20 WBC/µL.
The WBC differential includes the numbers of neutrophils,
lymphocytes, monocytes, and eosinophils. A cerebrospinal
fluid (CSF) specimen is pretreated with CSF reagent to fix and
spherize the cells. The prepared sample remains stable for
4 minutes to 4 hours when stored at 18°C to 30°C. The specimen is aspirated into the instrument and cells are differentiated and enumerated by three optical measurements. The
signals are digitized and used to construct the CSF cytogram.
With this system, more cells are counted, achieving increased
accuracy and precision. The automated RBC, WBC, polymorphonuclear, mononuclear, and differential results are available
within 1 minute of sample aspiration. In addition, the ADVIA
2120i can provide a rapid automated diagnostic test for fetal
lung maturity by counting lamellar bodies in amniotic fluid.
Lamellar bodies are counted in the platelet channel using high
and low laser light scatter. The analyzer is approved for counting cells in pleural fluids, peritoneal fluids, and peritoneal
dialysates.
The Sysmex XE-5000 is the newest generation hematology analyzer that includes a dedicated body fluid mode. 4 The
body fluid mode has extended cell counting to increase precision in samples with small numbers of cells. Body fluids
can be analyzed without sample preparation or pretreatment.
In the body fluid mode, a new software algorithm is used to
count RBCs using sheath flow impedance and WBCs using
side scatter and fluorescence intensity after dye-staining
3920_App A_283-292 23/01/14 9:17 AM Page 291
Appendix A | Urine and Body Fluid Analysis Automation 291
nuclear DNA or RNA. Polymorphonuclear cells and mononuclear cells are counted in the differential (DIFF) channel.
Mesothelial cells and macrophages are enumerated but are
not included in the cell count. It is recommended that only
nonmalignant fluid be analyzed on the XE-5000. In addition,
the differential scatterplots should be inspected visually
to detect non-cellular particulate matter such as bacteria,
Cryptococcus, and interference from large cells (macrophages and
mesothelial cells). With WBC counts below 10×106/µL cells,
differentiation between polymorphonuclear cells and
mononuclear cells should not be done.4
The iQ 200 using digital flow cell imaging can be used for
body fluids by adding the body fluids software module. The
body fluid menu includes CSF, synovial, pleural, peritoneal,
peritoneal dialysate, peritoneal lavage, pericardial, and general
serous fluids. Two dilutions are made on the specific fluid
based on the type of fluid and the appearance of the fluid. One
tube is diluted with an Iris (iQ) diluent and the other with an
Iris RBC-lysing reagent. The dilution-specific barcoded tubes
are loaded onto the instrument for counting. A total cell count
is derived from the Iris (iQ) diluent tube and the nucleated cell
count is obtained from the Iris lysing reagent dilution. The
difference between these two numbers equals the RBC count.
As with urine microscopy, results and cell images are sent to
an operator screen for review or autoverification and can be
sent directly to the LIS.
References
1. Laboratory Production Solutions, Iris Diagnostics, August 31,
2012.
2. Block, DR, and Lieske, JC: Automated Urinalysis in the Clinical
Lab. Medical Laboratory Observer (MLO), 44(10), Oct 2012.
3. Clinical and Laboratory Standards Institute: Body fluid analysis
for cellular composition: approved guideline, CLSI document
H-56A. CLSI, Wayne, PA, 2006.
4. deJonge R, Brouwer R, de Graaf MT, et al: Evaluation of the new
body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body
fluids. Clin Chem Lab Med 48:665–675, 2010.
Additional Information Sources
ARKRAY Inc., Kyoto, Japan: www.arkrayusa.com
Iris Diagnostics, Chatsworth, CA: www.irisdiagnostics.com
Roche Diagnostics, Indianapolis, IN: www.roche.com/products
Siemens Healthcare Diagnostics Inc., Deerfield, IL: www.usa.
siemens.com/diagnostics
Sysmex America, Inc. Mundelein, IL: www.sysmex.com/usa
3920_App A_283-292 23/01/14 9:17 AM Page 292
3920_App B_293-296 23/01/14 9:17 AM Page 293
APPENDIX
B
Bronchoalveolar Lavage
Analyzing specimens obtained by bronchoalveolar lavage
(BAL) is a method for obtaining cellular, immunologic, and
microbiologic information from the lower respiratory tract.
BAL is particularly useful in evaluating immunocompromised
patients, interstitial lung disease (infectious, non-infectious,
immunologic, or malignant), airway diseases, suspected alveolar hemorrhage, pulmonary alveolar proteinosis, Langerhans
cell histiocytosis, and dust exposure. It is often used in conjunction with high-resolution computerized tomography
(HRCT), medical history, and physical examination to determine the need for a surgical biopsy.
During bronchoscopy, a fiber-optic bronchoscope is
guided into a selected bronchopulmonary segment, usually the
right middle or lingular lobe; however, target areas are better
defined using HRCT before the procedure. Optimal targets are
areas of alveolar ground glass opacity, more prominent nodular
profusion, or fine reticulation.1 The segment lavaged should
be recorded on the requisition form. Aliquots of sterile normal
saline are instilled into the alveolar spaces through the bronchoscope to mix with the bronchial contents and are aspirated
for cellular examination and culture. The instillation volume
is between 100 and 300 mL of sterile saline in 20- to 50-mL
aliquots.2 The first aliquot is discarded, the remaining aliquots
are either sent individually for analysis or pooled for further
analysis.2 The desired fluid volume for analysis is 10 to 20 mL
(minimal volume is 5 mL). Optimal sampling retrieves greater
than 30% with a typical recovery range of 50% to 70%. Lowvolume recovery (less than 25%) caused by fluid retention in
the lung may appear in chronic obstructive lung diseases and
should be noted on the requisition form.
Keep specimens at room temperature during transport to
the laboratory and process them immediately. When delivery
to the laboratory is delayed for longer than 30 minutes, transport the specimens on ice (4°C).1 Specimens that will not be
analyzed immediately should be centrifuged, the cells resuspended in a nutrient-supplemented medium, and refrigerated
at 4°C for up to 24 hours.1 Specimens are unacceptable for
testing after 24 hours. Cell counts should be performed within
1 hour or are stable for up to 3 hours if the fluid is in a
nutrient-supplemented medium.2 Samples can be filtered
through loose gauze (50 to 70 µm nylon filter) to remove
mucus, phlegm, and dust.
Diagnostic tests on BAL fluid include a cell count with differential, microbiologic studies, and cytopathology. A macroscopic observation is recorded describing the color and clarity
of the specimen. The appearance of the BAL fluid can provide
valuable diagnostic information. BAL fluid color can be clear
(colorless), milky white, light brown-beige, and red. BAL
fluid clarity may be described as clear, hazy, cloudy, or turbid.
A bloody BAL fluid with increasing intensities during the
sequential aliquots indicates acute diffuse alveolar hemorrhage,
whereas orange-red BAL fluid is the result of an older hemorrhagic syndrome and would be evaluated for intracellular iron
content by cytochemistry.2 A milky or light brown-beige color
BAL fluid indicates an accumulation of phospholipid-protein
complexes derived from pulmonary surfactant in the lung
alveoli and strongly suggests pulmonary alveolar proteinosis.
The BAL fluid should be centrifuged if it looks milky.2 The
presence of clots should be noted. The fluid volume is measured and cell counts and differential counts are performed.
White and Red Blood Cell
Counts
White blood cell (WBC) and red blood cell (RBC) counts are
performed on BAL and may be diluted to facilitate counting
using a hemocytometer. Cell viability can be determined by
adding Trypan blue. Counts also can be performed with certain
automated cell counters as designated by the manufacturer.
When cell concentration is less than the automated instrument’s
linearity specifications, hemocytometry should be used.2
If a hemocytometer is used, WBC counts may be diluted
using the BMP LeukoChek system to facilitate counting. A
BMP LeukoChek system is available with a 1 to 100 dilution
of ammonium oxalate to lyse the RBCs. When the RBCs
have lysed and the solution is clear, plate the fluid on a
hemocytometer and allow the cells to settle for 5 minutes.
Count all cells in the 18 squares on both sides of the hemacytometer and calculate the average of the two sides. Using
the following formula, calculate the WBC count using the
following formula:3
WBC/cmm =
average number of cells × dilution factor × 10
9 squares
RBC counts may be diluted with isotonic saline using an
MLA pipette. Plate the fluid on a hemocytometer and allow it
to settle for 5 minutes. Count both sides of the hemocytometer
and use the following formula to calculate the RBC/cmm:3
RBC/cmm =
number of cells × dilution factor × 10
Number of squares counted
Cells must be evenly distributed over the hemocytometer
surface. For a leukocyte count within the reference range, there
should be no more than a 15-cell difference between the highest and lowest total number of cells found among the squares
counted. For a RBC count, there should be no more than a
30-cell difference between the highest and lowest total number
of cells found among the squares counted. Total cells counted
293
3920_App B_293-296 23/01/14 9:17 AM Page 294
294
Appendix B | Bronchoalveolar Lavage
on each side of the counting chamber should agree within 10%
of each other. Counts that do not meet this standard should
not be reported. Mix the specimen well and repeat the count.
If clumps of cells or clots are present, note on the requisition
that the “cell count may be inaccurate due to clumps of
cells and/or clots.” BAL body fluids may not be counted on
the Sysmex instrumentation because of the varied types of
cells present.3
Leukocytes
Evaluating the predominant inflammatory cellular pattern provides valuable information to the clinician in determining a
differential diagnosis. The morphologic appearance of cells and
particles, such as the morphology of macrophages in extrinsic
allergic alveolitis and sarcoidosis, or the detection of dust particles in occupational exposure conditions, provides diagnostic
information.2
Differential slides are prepared by cytocentrifugation
using routine procedures with staining (Wright-Giemsa or
May Grunwald-Giemsa) and at least 300 cells but often 500 to
1000 cells are counted and classified.4 Cells seen in BAL
fluid include macrophages, lymphocytes, ratio of CD4+ and
CD8+ lymphocytes (CD4/CD8 ratio), neutrophils, eosinophils,
ciliated columnar bronchial epithelial cells, and squamous
epithelial cells.
Macrophages, often containing a variety of phagocytized
material, are the cells most frequently seen, in numbers ranging
from 56% to 80% (Fig. B–1). Phagocytized material includes
hemosiderin; golden, brown, or black pigment inclusions; or
foamy cells. A predominance of macrophages containing
smoking-related inclusions suggests smoking-related interstitial lung disease or pulmonary Langerhans cell histiocytosis.1
Lymphocytes, normally constituting 1% to 15% of the cell
population, are increased in interstitial lung disease, drug reactions, pulmonary lymphoma, and nonbacterial infections. A
lymphocyte differential count equal to or greater than 25%
suggests granulomatous lung disease, whereas a lymphocyte
differential count greater than 50% suggests hypersensitivity
pneumonitis or nonspecific interstitial pneumonia.1 The ratio
Figure B–1 Bronchoalveolar lavage: Normal macrophages and lymphocytes (×1000).
of CD4 to CD8 lymphocytes further defines the disease
process. An elevated CD4/CD8 indicates sarcoidosis or connective tissue disorders. A normal CD4/CD8 is associated
with tuberculosis or malignancies, whereas a low CD4/CD8 indicates hypersensitivity pneumonitis, silicosis, drug-induced
disease, or HIV infection. Immunologic analysis is performed
by flow cytometry.
Neutrophils are the primary granulocyte seen, with a
normal value of less than 3%. They are elevated in cigarette
smokers, and in cases of bronchopneumonia, toxin exposure,
and diffuse alveolar damage. A neutrophil count equal to or
greater than 50% strongly suggests acute lung injury, aspiration
pneumonia, or suppurative infection.1
Eosinophils, usually less than 1% to 2% of the total cells,
are elevated in asthma, drug-induced lung disease, infections
(parasitic, mycobacterial, or fungal), hypersensitivity, pneumonitis, and eosinophilic pneumonia. An eosinophil differential count greater than or equal to 25% diagnoses eosinophilic
lung disease.1
A mast cell differential count greater than 1% combined
with a lymphocyte count greater than 50% and a neutrophil
count greater than 3% strongly suggests hypersensitivity
pneumonitis.1
Erythrocytes
The presence of erythrocytes indicates an acute alveolar hemorrhage. Phagocytosed erythrocytes suggest that an alveolar
hemorrhage has occurred within the past 48 hours, whereas
hemosiderin-laden macrophages indicate an alveolar hemorrhage older than 48 hours.
Epithelial Cells
Ciliated columnar bronchial epithelial cells are more numerous in bronchial wash specimens than in bronchial lavage
specimens because of the more vigorous washing technique.
In a lavage specimen, these cells normally range from 4% to
17% (Fig. B–2).
Figure B–2 Bronchoalveolar lavage: Ciliated bronchial epithelial cells;
notice the eosinophilic bar (×1000).
3920_App B_293-296 23/01/14 9:18 AM Page 295
Appendix B | Bronchoalveolar Lavage 295
Fungi, Viruses, and Bacteria
Fungal elements and viral inclusions may also be observed
in respiratory specimens. Organisms identified include Pneumocystis carinii, Toxoplasma gondii, Strongyloides stercoralis,
Legionella pneumophila, Cryptococcus neoformans, Histoplasma
capsulatum, Mycobacterium tuberculosis, Mycoplasma pneumoniae, influenza A and B viruses, and respiratory syncytial
virus. Quantitative or semiquantitative cultures are useful
for ventilator-associated pneumonia and can diagnose the
infection if the organism is identified. With the increasing
concern about nosocomial infections and antibiotic-resistant
microorganisms, BAL is more frequently performed on
ventilator-assisted patients to detect infection and monitor
antibiotic therapy.
Bronchoalveolar lavage is becoming an important diagnostic test for P. carinii in immunocompromised patients. With
P. carinii, characteristic amorphous material is seen microscopically under low power and organisms are visible under high
power (Figs. B–3 and B–4).5 C. neoformans has become a
significant opportunistic pathogen in patients with AIDS. A
diagnosis of pulmonary cryptococcosis can be made by
demonstrating a positive cryptococcal antigen in respiratory
specimens exhibiting yeast cells that morphologically resemble
C. neoformans. The extent of the cryptococcal infection correlates with the antigen titer.
Figure B–4 Bronchoalveolar lavage: Characteristic cup-shaped organisms indicating P. carinii (×1000).
Cytology
Cytologic studies include observing sulfur granules (actinomycetes), hemosiderin-laden macrophages, Langerhans cells,
cytomegalic cells, fat droplets seen in fat embolism with an
Oil Red O stain, and lipid-laden alveolar macrophages using a
Sudan III stain. Periodic acid Schiff staining or Oil Red O staining may be useful in diagnosing pulmonary alveolar proteinosis
or aspiration.1 Dust particle inclusions indicate pneumoconioses or asbestos exposure. Specimens are evaluated by a
pathologist in cytology whenever malignancy is suspected.
References
Figure B–3 Bronchoalveolar lavage: Amorphous material associated
with P. carinii when examined under low power (×100).
1. Meyer, KC, Raghu, G, Baughman, RP, et al.: An official American
Thoracic Society clinical practice guideline: The clinical utility of
bronchoalveolar lavage cellular analysis in interstitial lung disease.
Am J Respir Crit Care Med 185(9):1004–1014, May 1, 2012.
doi:10.1164/rccm.201202-0320ST.
2. Clinical and Laboratory Standards Institute: Body Fluid Analysis
for Cellular Composition; Approved Guideline. CLSI document
H56-A. Clinical and Laboratory Standards Institute. Wayne, PA
2006.
3. Bronchoalveolar Lavage, BAL Cell Count and Differential.
Methodist Hospital: Clinical Laboratory Procedure Manual.
Omaha, NE, January 5, 2012.
4. Jacobs, JA, DeBrauwer, EI, et al: Accuracy and precision of
quantitative calibrated loops in transfer of bronchoalveolar
lavage fluid. J Clin Micro 38(6):2117–2121, 2000.
5. Linder, J: Bronchoalveolar Lavage. ASCP, Chicago, 1988.
3920_App B_293-296 23/01/14 9:18 AM Page 296
3920_Ans_297-304 23/01/14 9:15 AM Page 297
Answers to Study Questions and Case
Studies and Clinical Situations
Chapter 1
Study Questions
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
C
A
D
A
B
A
C
D
D
C
B
A
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
B
D
A
B
C
C
A
B
D
B
A
C
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
D
D
D
B
2, 1, 2, 3, 2, 1
D
C
D
C
D
Case Studies and Clinical Situations
1. a. Review of the procedure by a designated authority
has not been documented.
b. Instructions and training are not being provided to
personnel performing collections.
c. A safety statement about the heat produced by the
reaction is not in the procedure manual.
d. The bottles have not been dated and initialled.
2. a. Correct; proficiency survey tests should be rotated
among personnel performing the tests.
b. Accept; QC on the Clinitest tablets must only be
performed when they are used to perform a test.
c. Correct; documentation of technical competency
should be performed on all personnel working in the
section and educational qualifications assessed.
3. a. The procedure was being performed incorrectly.
The correct timing of the glucose reaction was not
being done.
b. The technologist performing the test. QC ensures
that the reagents and instrument are working properly and that the technologist is performing the test
correctly.
c. At the beginning of each shift, when a new bottle
of reagent is opened or as stated in the procedure
manual.
d. Refer to the procedure manual. Check expiration
dates of controls and reagents. Open and test a new
bottle of control or reagents.
e. When the controls are within range.
4. a. Delay in testing the specimen.
b. Incident report.
c. Delta check.
d. Treatment of the patient will be delayed because the
specimen will need to be recollected and tested. Extra
expense incurred.
e. Errors should be corrected as soon as possible following the institution’s policy. The original result must
not be erased.
Chapter 2
Study Questions
1.
2.
3.
4.
5.
6.
7.
C
B
C
A
D
C
C
8.
9.
10.
11.
12.
13.
14.
D
A
A
B
B
D
A
15.
16.
17.
18.
19.
20.
C
C
A
D
B
B
Case Studies and Clinical Situations
1. a. It could have increased pH, nitrite and bacteria
and decreased clarity, glucose, ketones, bilirubin,
urobilinogen and WBCs, RBCs and casts.
b. The specimen was refrigerated and was brought
immediately to the laboratory.
2. a. It would be less clear.
b. Additional epithelial cells and bacteria (making it not
acceptable for a culture).
3. a. The results would be falsely decreased.
b. The patient needs to collect another specimen.
4. a. Yes.
b. The temperature would be lower than body temperature.
c. The specimen tested was not from the defendant.
d. An accurately filled out chain of custody form (COC).
297
3920_Ans_297-304 23/01/14 9:15 AM Page 298
298
Answers to Study Questions and Case Studies and Clinical Situations
Chapter 3
Chapter 4
Study Questions
Study Questions
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
B
D
C
D
A
B
C
D
B
A
C
D
D
14.
15.
16.
17.
18.
19.
20.
21.
22.
B
B
D
B
A. Beta2-microglobulin;
B. Creatinine;
C. Cystatin
C; D. 125Iiodothalamate
B
69 mL/min
D
D
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
B
D
D
C
C
B
A
+0.5
D
600 mL/min
C
B
Case Studies and Clinical Situations
1. a. 160-mg/dL to 180-mg/dL.
b. Renal tubular reabsorption is impaired.
2. a. Juxtaglomerular apparatus → Angiotensinogen
→ Renin → Angiotensin I → Angiotensin II.
b. Vasoconstriction, increased sodium reabsorption, and
increased aldosterone to retain sodium.
c. Production of renin decreases and, therefore, the
actions of the renin-angiotensin-aldosterone system.
3. a. The physician can calculate the approximate creatinine
clearance using the MDRD-IDMS-traceable formula.
b. The cystatin C test and the beta2-microglobulin test
serum tests.
c. No. The beta2-microglobulin test requires a normal
immune system and malignancies can affect the
immune system; therefore, the test cannot be reliable in patients with immunologic disorders and
malignancies.
4. a. Yes. Serum from the midnight specimen is not being
separated from the clot and refrigerated in a timely
manner.
b. Lactic acid will be present in serum that is not
separated from the clot and will affect the freezing
point osmolarity readings.
c. If the laboratory is using a freezing point osmometer,
results will be affected by alcohol ingestion; vapor
pressure results would not be affected and could be
used as a comparison.
5. a. Diabetes insipidus.
b. Neurogenic diabetes insipidus.
c. Nephrogenic diabetes insipidus.
1.
2.
3.
4.
5.
6.
7.
8.
A
D
A
D
A
A
C
C
9.
10.
11.
12.
13.
14.
15.
16.
D
A
C
B
D
A
C
B
17.
18.
19.
20.
21.
22.
23.
24.
D
D
C
B
B
A
B
D
Case Studies and Clinical Situations
1. a. An elevated pH and a positive reagent strip reaction
for nitrite.
b. The reagent strip specific gravity would be much
lower if the patient had been given radiographic dye.
c. The reagent strip test for bilirubin would be positive.
d. The reagent strip reaction for blood would be positive
and red blood cells would be seen in the microscopic.
2. a. 1.018
b. Yes.
c. It would agree with the reagent strip reading because
like the osmometer, the reagent strip is not affected
by high-molecular-weight substances.
3. Hemoglobin and myoglobin.
a. Examine the patient’s plasma /serum. The breakdown
of red blood cells to hemoglobin produces a red
serum. Myoglobin is produced from skeletal muscle
and is rapidly cleared from the plasma/serum.
4. a. Mrs. Smith has been eating fresh beets.
b. Yes. The pH of Mrs. Smith’s urine is acidic or she has
not recently consumed fresh beets.
5. No. The urine can contain increased pH, glucose, ketones,
bilirubin, urobilinogen, nitrite, and small amounts of
cellular structures.
Chapter 5
Study Questions
1.
2.
3.
4.
5.
6.
7.
A
D
A
C
D
A
D
8.
9.
10.
11.
12.
13.
14.
B
D
2,1,2,3,1,2,3
B
A
A
D
15.
16.
17.
18.
19.
20.
21.
B
A
C
A
A
C
A
3920_Ans_297-304 23/01/14 9:15 AM Page 299
Answers to Study Questions and Case Studies and Clinical Situations
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
B
C
A
C
B
A
D
A
C
1, 2, 1, 2, 1, 2
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
B
A
1,3,4,2
A
D
C
A
C
A
B
42.
43.
44.
45.
46.
47.
48.
49.
B
D
C
B
C
C
A
C
Case Studies and Clinical Situations
1. a. The blood glucose is elevated and has exceeded the
renal tubular maximum (Tm) for glucose.
b. Diabetes mellitus.
c. It indicates diabetes mellitus related renal disease.
d. Renal tubular reabsorption disorders.
2. a. Yellow foam.
b. Possible biliary-duct obstruction preventing bilirubin
from entering the intestine.
c. Icteric.
d. Protection from light.
3. a. Hemoglobinuria.
b. Increased hemoglobin presented to the liver results
in increased bilirubin entering the intestine for
conversion to urobilinogen.
c. The circulating bilirubin is unconjugated.
d. It would if a multisix reagent strip is used and would
not if a Chemstrip is used. A Watson-Schwartz test is
more specific for porphobilinogen.
4. a. Negative chemical reactions for blood and nitrite.
Ascorbic acid interference for both reactions. A random specimen or further reduction of nitrite could
cause the negative nitrite.
b. Glucose, bilirubin, LE. Ascorbic acid is a strong reducing agent that interfers with the oxidation reaction
in the glucose test. Ascorbic acid combines with the
diazo reagent in the bilirubin and LE tests, lowering
the sensitivity.
c. The dark yellow color may be caused by beta-carotene
and vitamin A, and some B vitamins also produce
yellow urine.
d. Non-nitrite–reducing microorganisms; lack of dietary
nitrate; antibiotic administration.
5. a. To check for possible exercise-induced abnormal results.
b. Negative protein and blood, possible changes in color
and specific gravity.
c. Renal.
299
6. a.
b.
c.
d.
7. a.
No, the specimen is clear.
Myoglobinuria.
Muscle damage from the accident (rhabdomyolysis).
Yes. Myoglobin is toxic to the renal tubules.
Laboratory personnel are not tightly capping the
reagent strip containers in a timely manner.
b. Personnel performing the CLIA-waived reagent strip
test are not waiting 2 minutes to read the LE reaction.
c. The student is not mixing the specimen.
d. The reagent strips have deterioated and the quality
control on the strips was not performed prior to
reporting the results.
Chapter 6
Study Questions
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
A
D
C
C
A
B
C
D
C
D
D
A
C
B
C
A
D
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
D
B
C
A
B
C
D
D
B
D
A
B
C
C
D
D
B
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
A
C
A
D
A
C
D
A
A
C
D
C
4, 3, 5, 1
3, 5, 2, 6, 4
4, 8, 7, 6, 1, 5
3, 5, 2, 1, 7, 4
Case Studies and Clinical Situations
1. a. Yeast grows best at a low pH with an increased concentration of glucose.
b. Yes, this exceeds the renal threshold.
c. No, yeast is not capable of reducing nitrate to
nitrite.
d. Moderate blood with no RBCs.
e. Myoglobin is the cause of the positive chemical test
result for blood. The patient has been bed-ridden
for an extended period of time, causing muscle
destruction.
3920_Ans_297-304 23/01/14 9:15 AM Page 300
300
Answers to Study Questions and Case Studies and Clinical Situations
2. a. The large objects are in a different plane from that of
the urinary constituents.
b. Contamination by artifacts.
c. No, because they are in a different plane.
d. Polarizing microscopy.
3. a. Renal tubules.
b. Yes, viral infections can cause tubular damage.
c. RTE cells absorb the bilirubin-containing urinary
filtrate.
d. Liver damage inhibits processing of reabsorbed
urobilinogen.
e. Hemolytic anemia.
4. a. The patient is taking a pigmented medication, such as
phenazopyridine.
b. Yes.
c. Ask what medications the patient is taking.
d. Ampicillin.
5. a. Calcium oxalate.
b. Monohydrate and dihydrate calcium oxalate.
c. Oval: monohydrate; envelope: dihydrate.
d. Monohydrate.
6. a. Microscopic results do not match the chemical tests
for blood, nitrite, and leukocyte esterase.
b. The specimen has been unpreserved at room temperature for too long, the cells have disintegrated, and
the bacteria have converted the nitrite to nitrogen.
c. The pH.
d. Ask the clinic personnel to instruct the patient to collect a midstream clean-catch specimen and have the
specimen delivered immediately to the laboratory.
7. a. No, because they are associated with strenuous
exercise.
b. The positive blood reaction is from hemoglobinuria
or myoglobinuria resulting from participating in a
contact sport. The protein is orthostatic.
c. Increased excretion of RTE cell lysosomes in the
presence of dehydration.
8. a. Yes, the waxy casts are probably an artifact such as
a diaper fiber. Waxy casts are not associated with
negative urine protein.
b. No, this is normal following an invasive procedure.
c. Yes, tyrosine crystals are seen in severe liver disease;
therefore, the bilirubin should be positive. The
crystals may be an artifact or from a medication.
d. Yes, uric acid crystals may be mistaken for cystine
crystals.
e. Yes, radiographic dye crystals associated with a high
specific gravity resemble cholesterol crystals.
f. No, Trichomonas is carried asymptomatically by men.
g. No, calcium carbonate crystals are found in alkaline
urine; therefore, clumps of amorphous phosphates
may be present.
Chapter 7
Study Questions
1.
2.
3.
4.
5.
6.
7.
B
C
B
C
B
D
C
8.
9.
10.
11.
12.
13.
14.
D
A
C
C
C
B
D
15.
16.
17.
18.
19.
20.
A
C
A
A
A
D
Case Studies and Clinical Situations
1. a. Acute glomerulonephritis.
b. M protein in the cell wall of the group A
streptococcus.
c. Glomerular bleeding.
d. No, they are also passing through the damaged
glomerulus.
e. Good prognosis with appropriate management of
secondary complications.
f. Henoch-Schönlein purpura.
2. a. IgA nephropathy.
b. Serum IgA level.
c. Chronic glomerulonephritis/end-stage renal
disease.
d. Impaired renal tubular reabsorption associated with
end-stage renal disease.
e. The specific gravity is the same as that of the ultrafiltrate, indicating a lack of tubular concentration.
f. The presence of extreme urinary stasis.
3. a. Nephrotic syndrome.
b. Nephrotic syndrome may be caused by sudden,
severe hypotension.
c. Changes in the electrical charges of the shield of
negativity produce increased membrane permeability.
d. Decreased plasma albumin lowers the capillary oncotic pressure, causing fluid to enter the interstitial
tissue.
e. Reabsorption of filtered lipids by the RTE cells.
4. a. Minimal change disease.
b. Nephrotic syndrome, focal segmental
glomerulosclerosis.
c. Good prognosis with complete remission.
3920_Ans_297-304 23/01/14 9:15 AM Page 301
Answers to Study Questions and Case Studies and Clinical Situations
5. a. Goodpasture syndrome.
b. The autoantibody attaches to the glomerular capillaries, causing complement activation and destruction of
the capillaries.
c. Wegener’s granulomatosis.
d. Antineutrophilic cytoplasmic antibody.
e. Granuloma formation resulting from autoantibodies
binding to neutrophils in the vascular walls and
initiating an immune response.
6. a. Cystitis, UTI.
b. The specimen is very dilute.
c. Irritation of the urinary tract will cause a small
amount of bleeding. The cells and bacteria may cause
a trace protein or it may be a false-positive due to the
high pH.
d. Yes, glitter cells are seen in hypotonic urine.
e. Female children.
f. Pyelonephritis.
7. a. Intravenous pyelogram.
b. Chronic pyelonephritis.
c. WBC cast.
d. Reflux nephropathy.
e. Performing a Gram stain.
f. Radiographic dye.
g. Permanent tubular damage and progression to
chronic, end-stage renal disease.
8. a. Abnormal.
b. Acute interstitial nephritis.
c. This disorder is an inflammation not an infection.
d. Discontinue the medication because it is causing the
allergic reaction.
9. a. Acute renal failure.
b. The prerenal sudden decrease in blood flow to the
kidneys.
c. Lack of renal concentrating ability.
d. Tubular damage.
e. The increased diameter of the damaged distal convoluted tubule and extreme urinary stasis allowing casts
to form in the collecting ducts.
10. a. Renal lithiasis.
b. The high specific gravity.
c. Yes, the dark yellow color and high specific gravity
indicate a concentrated urine, which induces the
formation of renal calculi.
d. Calcium oxalate.
e. Increased hydration and dietary changes.
301
Chapter 8
Study Questions
1.
2.
3.
4.
5.
6.
7.
8.
9.
A
C
B
C
A
A
C
B
D
10.
11.
12.
13.
14.
15.
16.
17.
18.
D
D
B
C
A
D
B, A, B, B, A
D
B
19.
20.
21.
22.
23.
24.
25.
26.
27.
B
B
D
D
D
C
B
D
D, F, A, E, C, B
Case Studies and Clinical Situations
1. a.
b.
c.
d.
2. a.
b.
c.
3. a.
b.
c.
d.
e.
4. a.
b.
c.
d.
e.
5. a.
b.
c.
6. a.
b.
c.
7. a.
b.
c.
d.
e.
Underdevelopment of the liver.
Yes, with severe acquired liver disease.
Tyrosine crystals; leucine crystals, bilirubin crystals.
Protect the specimen from light.
Isovaleric acidemia.
Maple syrup urine disease.
Yes, the MS/MS screen would be positive.
Renal lithiasis.
Impaired renal tubular reabsorption of cystine.
Lysine, arginine, ornithine.
They are more soluble than is cystine.
The disorder is inherited.
Yes.
Yes, uric acid crystals accumulating on the surface of
the diaper could have an orange color.
Lesch-Nyhan disease.
Yes, the disease is inherited as a sex-linked recessive.
Hypoxanthine guanine phosphoribosyltransferase.
Yes. The urine may contain melanin or homogentisic
acid.
Yes. Melanin will react with sodium nitroprusside, the
reagent used on reagent strips for the detection of ketones.
Yes. Homogentisic acid turns black in alkaline urine.
Yes, the purple blue color could indicate the presence
of indican in the urine.
Hartnup disease.
Good with proper dietary supplements.
The Ehrlich reaction
Acetylacetone.
Porphobilinogen.
Blood.
Free erythocyte protoporphyrin (FEP).
3920_Ans_297-304 23/01/14 9:15 AM Page 302
302
Answers to Study Questions and Case Studies and Clinical Situations
Chapter 9
Study Questions
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
B
C
B
A
B
B, B, A, A
C
A
C
C
D
D
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
A
B
C
D
D
D
B
D
A
B
B
B
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
C
A
C
A
C
D
B
A
A
C
C
D
Case Studies and Clinical Situations
1. a. Cerebral hemorrhage because of the presence of
erythrophagocytosis, even distribution of blood, and
patient’s history.
b. No, they would be consistent with peripheral blood
entering the CSF.
c. No, they are consistent with the percentages seen in
peripheral blood.
d. Hemosidern granules and hemotoidin crystals.
e. A traumatic tap.
2. a. An India ink preparation.
b. Cryptococcus meningitis.
c. Immunologic testing for Cryptococcus.
d. Rheumatoid factor.
e. Acid-fast staining and culture.
f. Noticeable oligoclonal bands in both the CSF and
serum.
3. a. CSF/serum albumin index = 6.7.
b. Yes.
c. IgG index = 1.5.
d. Immunoglobulin synthesis within the CNS.
e. Multiple sclerosis.
f. Oligoclonal banding only in the CSF.
g. Myelin basic protein.
4. a. Viral, tubercular, or fungal meningitis.
b. No, the Gram stain would be negative in viral and
tubercular and not always positive in fungal meningitis.
c. Yes. Lymphocytes are very predominant in viral
meningitis.
d. Yes, a CSF lactate level of 25 mg/dL or less would aid
in confirming bacterial meningitis. The lactate level
would be higher in tubercular and fungal meningitis.
5. a. Stain precipitate is being confused with Grampositive cocci.
b. Differentials are being reported from the counting
chamber.
c. The albumin is contaminated.
d. The specimens are not being promptly delivered to
the laboratory.
Chapter 10
Study Questions
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
C
D
B
C
D
A
B
D
C
B
B
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
C
A
A
B
B
A
C
A
C
A
A
23.
24.
25.
26.
27.
28.
29.
30.
31.
D
B
D
B
D
B
C
A
B
Case Studies and Clinical Situations
1. a.
b.
c.
d.
2.
3.
4.
5.
6.
Sperm concentration, motility, and morphology.
21,000,000; no.
1,800,000; no.
Yes. The normal sperm concentration is 20 to
60 million/mL. Spermatid counts over 1 million
are considered abnormal. Both of these abnormal
results and the abnormal motility are related to defects in sperm maturation.
a. Male antisperm antibodies may form following
vasovasostomy procedures.
b. The MAR test and the immunobead test.
c. The MAR test detects the presence of IgG male sperm
antibodies. The immunobead test delineates the areas
of the sperm (head, tail, neck) that are affected by the
antibodies.
d. Clumping, ovum penetration, and motility.
The specimen contains urine, which is toxic to sperm,
therefore decreasing viability.
The specimen was improperly collected, and the first
part of the ejaculation was lost.
a. Yes, there is insufficient prostatic fluid present.
b. Zinc, citrate, and acid phosphatase.
c. Sperm motility is severely affected.
a. Acid phosphatase and seminal glycoprotein p30 tests.
b. Microscopic examination for the presence of sperm.
3920_Ans_297-304 23/01/14 9:16 AM Page 303
Answers to Study Questions and Case Studies and Clinical Situations
Chapter 11
Case Studies and Clinical Situations
Study Questions
1.
2.
3.
4.
5.
B
A
A
B
B, C, B, A, D,
B, D
6. A
7. B
8. B
9.
10.
11.
12.
13.
14.
15.
16.
17.
303
B
C
A
A
C
A
B
B
A
18.
19.
20.
21.
22.
23.
25.
D
B
Negative
C
A
C
A
Case Studies and Clinical Situations
1. a. 1. Sterile, heparinized tube, liquid EDTA tube,
nonanticoagulated tube.
b. MSU crystals are seen in gout.
c. Highly birefringent, needle-shaped crystals under
polarized light that turn yellow when aligned with
the slow vibration of red compensated polarized light.
d. Infection is frequently a complication of severe
inflammation.
2. a. WBC diluting fluid containing acetic acid was used.
b. Normal, hypotonic, or saponin-containing saline
should be used.
c. Crystal-induced inflammatory and septic.
d. Gram stain and culture, crystal examination.
3. a. Noninflammatory.
b. Hydroxyapatite crystals.
c. Glucose. A normal result is consistent with noninflammatory arthritis.
4. a. Fibrinogen.
b. EDTA or heparinized tube.
c. No, the bacteria will be trapped in the clot.
1. a. Pleural fluid.
b. Transudate, because all the test results are consistent
with those of a transudate.
c. Pleural fluid to serum ratios of cholesterol and
bilirubin.
2. a. Pneumonia.
b. Chest tube drainage.
3. a. 1.6.
b. Transudate. The SAAG is above 1.1.
c. Hepatic disorder.
4. a. To differentiate between cirrhosis and peritonitis;
cirrhosis.
b. Pancreatitis or gastrointestinal perforation; alkaline
phosphatase.
c. Rupture or accidental puncture of the bladder.
d. To detect the presence of gastrointestinal (CEA) and
ovarian (CA 125) cancers.
5. The patient has been a victim of blunt trauma and the
physician wants to determine if abdominal bleeding is
occurring; abdominal bleeding.
6. Thyroid profile; CA 125.
Chapter 13
Study Questions
1.
2.
3.
4.
5.
6.
7.
B
C
A
C
B
A
D
8.
9.
10.
11.
12.
13.
14.
2, 4, 1, 3
A
C
B
True
A
True
15.
16.
17.
18.
19.
20.
C
True
C
B
B
D
Case Studies and Clinical Situations
Chapter 12
Study Questions
1.
2.
3.
4.
5.
6.
7.
C
D
A
D
C
D
B, A, A, A, B,
A, B
8. B
9.
10.
11.
12.
13.
14.
15.
16.
17.
B
C
D
D
D
C
B
A
D
18.
19.
20.
21.
22.
23.
24.
25.
26.
B
C
B
B
B
C
B
D
D
1. a. Yes.
b. FLM.
c. The level of phosphatidylglycerol present in the fetal
lungs.
d. Phosphatidylglycerol is essential for FLM, and levels
do not always parallel lecithin levels in fetuses of
diabetic mothers.
2. a. A neural tube disorder such as spina bifida or
anencephaly.
b. An acetylcholinesterase level.
c. The amniotic fluid specimen contains blood.
3920_Ans_297-304 23/01/14 9:16 AM Page 304
304
Answers to Study Questions and Case Studies and Clinical Situations
3. a.
b.
c.
d.
4. a.
b.
c.
d.
5. a.
False-positive result.
False-positive result.
No effect.
False-positive result.
False-positive result.
False-positive result.
False-positive or test interference.
No effect.
The specimen was exposed to light, possible wrong
specimen sent.
Chapter 14
3. a. Patient #1: gastric reflux medication containing
bismuth may produce black stools; Patient #2:
medications such as aspirin and other NSAIDs may
cause gastric bleeding; Patient #3: red meat was not
avoided for 3 days prior to sample collection.
b. Provide dietary and medication instructions to patients.
c. The Hemoccult ICT immunochemical test.
4. a. The APT test cannot be performed because the
hemoglobin is already denatured.
b. The pH will be low because increased carbohydrates
are available for bacterial metabolism.
c. The infant had ingested maternal blood.
d. Yes, adequate carbohydrates are not present, and fats
are being metabolized for energy.
Study Questions
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
C
A
C
B
D
D
D
C
D
C
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
A
C
D
B
B
False
C
C
C
D
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
B
C
B
A
B
B
A
C
C
B
Case Studies and Clinical Situations
1. a. Secretory diarrhea.
b. Stool culture.
c. Probable: Salmonella, Shigella, Campylobacter, Yersinia,
E. coli; Improbable: Staphylococcus, Vibrio.
d. Osmotic diarrhea.
2. a. Microscopic examination for fecal fats.
b. Neutral fats stain directly and appear as large, orangered droplets; soaps and fatty acids appear as smaller
orange-red droplets after pretreatment of the specimen
with heat and acetic acid.
c. Quantitative fecal fat test.
d. Bulky and frothy.
e. Muscle fiber screening and the gelatin test for trypsin.
f. Muscle fiber: failure to include red meat in the diet;
gelatin test: intestinal degradation of trypsin or the
presence of trypsin inhibitors.
g. Chymotrypsin or elastase I.
Chapter 15
Study Questions
1.
2.
3.
4.
5.
D
B
C
A
C
6.
7.
8.
9.
10.
A
B
A
C
A
11.
12.
13.
14.
15.
C
B
C
A
D
Case Studies and Clinical Situations
1. a. Vaginal pH, saline and KOH wet preps, Gram stain.
b. KOH will reveal budding yeast.
c. Culture and DNA direct hybridization probe
(Affirm VPIII).
d. Vulvovaginal candidiasis caused by Candida albicans.
e. Antifungal agents.
2. a. Trichomoniasis caused by Trichomonas vaginalis.
b. Wet mount, vaginal pH, amine test from KOH prep,
DNA probe (Affirm VPIII), OSOM Trichomonas
Rapid Test.
c. Metronidazole.
d. Yes.
e. Complications include low birth rate, premature rupture
of membranes, preterm delivery during pregnancy.
3. a. Desquamative inflammatory vaginitis secondary to
atrophic vaginitis.
b. Reduced estrogen production in postmenopausal
women.
c. Hormone replacement therapy (estrogen).
3920_Abbreviations_305-306 23/01/14 9:14 AM Page 305
Abbreviations
AABB
A:C
ACE
AChE
ADA
ADH
AFP
AGN
AHG
AIDS
AIN
ALA
ANA
ANCA
AOA
ARF
ART
ASHI
ATN
BAL
BAT
BSI
BUN
BV
CAP
CASA
CDC
CEA
CHP
CLIA
CLRW
CLSI
CNS
COC
COLA
CPPD
CPR
CSF
CTAB
Cu2O
CuSO4
CV
DBDH
DCT
DI
DIDNTB
DIV
American Association of Blood Banks
albumin:creatinine [ratio]
angiotensin-converting enzyme
acetylcholinesterase
adenosine deaminase
antidiuretic hormone
alpha-fetoprotein
acute glomerulonephritis
antihuman globulin
acquired immunodeficiency syndrome
acute interstitial nephritis
␣ -aminolevulinic acid
antinuclear antibody
antineutrophilic cytoplasmic antibody
American Osteopathic Association
acute renal failure
assisted reproductive technology
American Society of Histocompatibility and
Immunogenetics
acute tubular necrosis
bronchoalveolar lavage
bacterial antigen test
body substance isolation
blood urea nitrogen
bacterial vaginosis
College of American Pathologists
computer-assisted semen analysis
Centers for Disease Control and Prevention
carcinoembryonic antigen
chemical hygiene plan
Clinical Laboratory Improvement Amendments
clinical laboratory reagent water
Clinical and Laboratory Standards Institute
central nervous system
chain of custody
Commission on Laboratory Assessment
calcium pyrophosphate dihydrate
cardiopulmonary resuscitation
cerebrospinal fluid
cetyltrimethylammonium bromide
cuprous oxide
copper sulfate
coefficient of variation
diisopropyl benzene dihydroperoxide
distal convoluted tubule
diabetes insipidus
(3⬘,3⬙, diodo 4⬘,4⬙-dihydroxy-5⬙,5⬙dinitrophenyl)-3,4,5,6-tetra-bromosulphonphtalein
desquamative inflammatory vaginitis
DNPH
EDS
EDTA
eGFR
ELISA
EPS
EQA
EQC
EU
FAH
FDA
FEP
fFN
FISH
FLM
FOBT
FSGS
FTA-ABS
GALT
gFOBT
GFR
GI
GTT
1-H NMR
H+
H2PO4
Hb
HBV
HCV
HCO3
HDN
HICPAC
5-HIAA
HIV
HLA-B12
hpf
HRCT
HSV
IBS
IDMS
IEF
IEM
IFE
iFOBT
IgA
IgG
IgM
ISO
2,4-dinitrophenylhydrazine
early dumping syndrome
ethylenediaminetetraacetic acid
estimated glomerular filtration rate
enzyme-linked immunoabsorbent assay
expressed prostatic secretions
external quality assessment
external quality control
Ehrlich unit
fumarylacetoacetate hydrolase
Food and Drug Administration
free erythrocyte protoporphyrin
fetal fibronectin
fluorescence in situ hybridization
fetal lung maturity
fecal occult blood testing
focal segmental glomerulosclerosis
fluorescent treponemal antibody-absorption
galactose-1-phosphate uridyl transferase
guaiac fecal occult blood test
glomerular filtration rate
gastrointestinal
glucose tolerance test
hydrogen nuclear magnetic resonance
spectroscopy
titratable acid/hydrogen ion
hydrogen phosphate ion
hemoglobin
hepatitis B virus
hepatitis C virus
bicarbonate ion
hemolytic disease of the newborn
Healthcare Infection Control Practices
Advisory Committee
5-hydroxyindoleacetic acid
human immunodeficiency virus
human leukocyte antigen-B12
high-power field
high-resolution computerized tomography
herpes simplex virus
irritable bowel syndrome
isotope dilution mass spectrophotometry
isoelectric focusing
inborn error of metabolism
immunofixation electrophoresis
immunochemical fecal occult blood test
immunoglobulin A
immunoglobulin G
immunoglobulin M
International Organization for Standardization
305
3920_Abbreviations_305-306 23/01/14 9:14 AM Page 306
306
Abbreviations
IUI
IVF
JC
KOH
LAF
LBC
LD
LE
LED
LIS
lpf
L/S
MAR
MBP
MDRD
MESNA
MoM
mOsm
MPGN
MSAFP
MS/MS
MSDS
MSU
MSUD
NaCl
NFPA
NH4+
NIRS
NKDEP
NRBC
NTD
OD
OSHA
PAH
PAMG-1
PB
PCR
PCT
intra-uterine insemination
in vitro fertilization
Joint Commission
potassium hydroxide
lateral flow assay
lamellar body count
lactate dehydrogenase
leukocyte esterase
light-emitting diode
laboratory information system
low-power field
lecithin-sphingomyelin ratio
mixed agglutination reaction
myelin basic protein
modification of diet in renal disease
mercaptoethane sulfonate sodium
multiples of the median
milliosmole
membranoproliferative glomerulonephritis
maternal serum alpha-fetoprotein
tandem mass spectrophotometry
Material Safety Data Sheet
monosodium urate (uric acid)
maple syrup urine disease
sodium chloride
National Fire Protection Association
ammonium ion
near-infrared spectroscopy
National Kidney Disease Education Program
nucleated red blood cell
neural tube defect
optical density
Occupational Safety and Health
Administration
p-aminohippuric acid
placental ␣ 1-microglobulin
peripheral blood
polymerase chain reaction
proximal convoluted tubule
PEP
PG
PKU
PM
POC
PPE
PPMT
PSA
PSP
PT
QA
QC
RA
RAAS
RBC
RCF
RDS
RF
RGE
RPM
RPR
RTE
SAAG
SD
SKY
SLE
SSA
STI
TAT
Tm
TmG
TMB
UP
UTI
VDRL
WBC
WHO
postexposure prophylaxis
phosphatidyl glycerol
phenylketonuria
preventive maintenance
point of care
personal protective equipment
pre- and post-massage test
prostate-specific antigen
phenolsulfonphthalein
proficiency testing
quality assurance
quality control
rheumatoid arthritis
renin-angiotensin-aldosterone system
red blood cell
relative centrifugal force
respiratory distress syndrome
rheumatoid factor
rapid gastric emptying
revolutions per minute
rapid plasma reagin
renal tubular epithelial (cells)
serum-ascites albumin gradient
standard deviation
fluorescent mapping spectral karyotyping
systemic lupus erythematosus
sulfosalicylic acid
sexually transmitted infection
turnaround time
maximal reabsorptive capacity/tubular
reabsorptive maximum
maximal tubular reabsorption capacity for
glucose
3,3⬘,5,5⬘-tetramethylbenzidine
Universal Precautions
urinary tract infection
Venereal Disease Research Laboratory
white blood cell
World Health Organization
3920_Glossary_307-314 23/01/14 10:48 AM Page 307
Glossary
2-hour postprandial specimen Fractional collection specimen; urine specimen collected 2 hours after eating
accreditation The process by which a program or institution
documents meeting established guidelines
accuracy Closeness of the measured result to the true value
acholic stools Pale-colored stools
acrosomal cap Tip of a spermatozoa head, which contains
enzymes for entry into an ovum
active transport Movement of a substance across cell membranes into the bloodstream by electrochemical energy
acute interstitial nephritis Inflammation of the renal interstitium and tubules frequently caused by a reaction to a
medication
acute phase reactants Low-molecular-weight plasma proteins associated with infection and inflammation
acute tubular necrosis Disorder affecting the renal tubular
cells caused by decreased renal blood flow or toxic
substances
adjusted body weight Actual body weight compared with
ideal body weight to correct for weight attributed to fat
and not muscle
aerosol Fine suspension of particles in air
afferent arteriole A small branch of the renal artery through
which blood flows to the glomerulus of the kidney
albinism An inherited condition marked by decreased production of melanin
albuminuria Protein (albumin) in the urine
aldosterone A hormone that regulates reabsorption of
sodium in the distal convoluted tubule
alimentary tract The digestive tract, including structures
between the mouth and the anus
alkaptonuria Homogentisic acid in the urine caused by a
failure to inherit the gene responsible for the production
of homogentisic acid oxidase
aminoacidurias Disorders in which increased amino acids
are present in the urine
amniocentesis Transabdominal puncture of the uterus and
amnion to obtain amniotic fluid
amnion The membranous sac that contains the fetus and
amniotic fluid
amniotic fluid Liquid that surrounds the fetus during
gestation
amyloid material A starch-like protein-carbohydrate complex that is deposited abnormally in tissue in some chronic
disease states
anaphylaxis Severe reaction caused by an autoimmune reaction to certain antigenic compounds
andrology The study of diseases of the male reproductive
organs
antidiuretic hormone Hormone produced by the hypothalamus to regulate water reabsorption in the collecting duct
antiglomerular basement membrane antibody Autoantibody against alveolar and glomerular capillary basement
membranes found in Goodpasture syndrome
antineutrophilic cytoplasmic antibody Autoantibody that
reacts with neutrophils in the renal tubules. Provides a
laboratory test for Wegener granulomatosis.
anuria Complete stoppage of urine flow
arachnoid granulations Projections on the arachnoid membrane of the brain through which cerebrospinal fluid is
reabsorbed
arthritis Inflammation of the synovial joints
arthrocentesis The puncture of a joint to obtain synovial
fluid
ascites Abnormal accumulation of peritoneal fluid
ascitic fluid Watery fluid that accumulates in the peritoneal
cavity in certain disease conditions
astrocytomas Tumors of the brain and spinal cord
atrophic vaginitis Syndrome in postmenopausal women
caused by reduced estrogen production
azotemia Increased nitrogenous waste products in the blood
bacterial endocarditis Inflammation of the endocardial
membrane of the heart caused by bacterial infection
bacterial vaginosis Inflammation of the vagina most often
caused by Gardnerella vaginalis
bacteriuria Bacteria in the urine
beta2 microglobulin A subunit of the class I major compatibility antigens that enters the blood at a constant rate
basal cells Cells located in the basal layer of the vaginal
stratified epithelium
bilirubin A bright yellow pigment produced in the degradation of heme
biliverdin Green pigment formed by the oxidation of
bilirubin
biohazardous Pertaining to a hazard caused by infectious
organisms
birefringent The ability to refract light in two directions
blood–brain barrier The barrier between the brain tissue
and capillary blood that controls the passage of substances
in the blood to the brain and cerebrospinal fluid
body substance isolation A guideline stating that all moist
body substances are capable of transmitting disease
Bowman’s capsule Part of the nephron that contains the
glomerulus
bright-field microscopy A procedure by which magnified
images appear dark against a bright background
bulbourethral glands Two small glands located on each side
of the prostate gland
307
3920_Glossary_307-314 23/01/14 10:48 AM Page 308
308
Glossary
carcinogenic Capable of causing cancer
casts Elements excreted in the urine in the shape of renal
tubules
catheterized specimen A urine specimen collected by
passing a sterile tube into the bladder
chain of custody Step-by-step documentation of the handling and testing of legal specimens
chain of infection A continuous link in the transmission of
harmful microorganisms between a source and a susceptible host
chemical hygiene plan Protocol established for the identification, handling, storage, and disposal of all hazardous
chemicals
chemical sieving Macroscopic screening of urine to determine the need for a microscopic examination
choroid plexuses A network of capillaries in the ventricle of
the brain that produces cerebrospinal fluid
chylous material A milky lymphatic fluid that contains
triglycerides and chylomicrons
cirrhosis Chronic liver disease that results in loss of liver cell
function
clarity Transparency of urine, ranging from clear to turbid
Clinical Laboratory Improvement Amendments Governmental regulatory agency that establishes quality standards
for laboratory testing
Clinical and Laboratory Standards Institute (CLSI) Nonprofit organization that publishes recommendations for
laboratory tests
clue cells Squamous epithelial cells covered with the gramnegative bacteria Gardnerella vaginalis
coefficient of variation Standard deviation expressed as a
percentage of the mean
collecting duct Part of the nephron where the final concentration of urine takes place through the reabsorption of
water
colligative property Freezing point, boiling point, vapor
pressure, or osmotic pressure property that is mathematically proportional to the concentration of a solution
compensated polarized light Polarized light, using a compensator to separate light rays into slow- and fast-moving
vibrations
constipation Infrequent production of feces that results in
small, hard stools
continuous quality improvement An institutional program
that focuses on customer satisfaction and expectations
control mean Average of all data points
control range Limit within which expected control values
lie, usually plus or minus two standard deviations from
the mean
countercurrent mechanism A selective urine concentration
process in the ascending and descending loops of Henle
creatinine A substance formed by the breakdown of creatine
during muscle metabolism
creatinine clearance A test used to measure the glomerular
filtration rate
crenated Shrunken and irregularly shaped or notched
cylindruria The presence of urinary casts
cystatin C Small protein produced at a constant rate by all
nucleated cells
cystinosis An inherited recessive disorder that disrupts the
metabolism of cystine
cystinuria Cystine in the urine that occurs as a result of a
defect in the renal tubular reabsorption of amino acids
cystitis An inflammation of the bladder
cytogenetic analysis An analysis of cellular chromosomes
dark-field microscopy Microscopic technique by which
magnified images appear bright against a dark background
D-dimer A product of fibrinolysis
demyelination The destruction of the myelin sheath that
protects a nerve
density Concentration of solutes present per volume of
solution
desquamative inflammatory vaginitis Syndrome characterized by purulent vaginal discharge, vaginal erythema, and
dyspareunia
diarrhea Watery stools
diarthroses Freely movable joints
disinfectant A substance that destroys microorganisms that
is used on surfaces rather than the skin
distal convoluted tubule Part of the nephron between the
ascending loop of Henle and the collecting duct where the
final concentration of urinary filtrate begins
dysentery An inflammation of the intestines that is caused
by microorganisms and results in diarrhea
dysmorphic Irregularly shaped
dyspareunia Abnormal pain during sexual intercourse
dyspnea Difficulty breathing
dysuria Painful urination
edema An accumulation of fluid in the tissues
efferent arteriole The small renal artery branch through
which blood flows away from the glomerulus
effusion An accumulation of fluid between the serous
membranes
electronic quality control Mechanical or electrical sample
used in place of a liquid control to verify reliability of
test results
endogenous procedure A test that uses a substance originating within the body
epididymis Small structure that forms the first part of the
secretory duct of the testes
erythrophagocytosis Engulfment of red blood cells by
macrophages
examination variable Processes that occur during testing of
a sample
exogenous procedure A test that requires a substance to be
infused into the body
external quality assessment Use of quality control materials
from an outside agency to monitor reliability of test results
external quality control Commercial controls used to verify
accuracy and reliability of patient test results
exudate Serous fluid effusion caused by conditions producing damage to the serous membranes
3920_Glossary_307-314 23/01/14 10:48 AM Page 309
Glossary
Fanconi syndrome A group of disorders marked by renal
tubular dysfunction associated with some inherited and
acquired conditions
fasting specimen The second voided urine specimen collected after fasting
ferritin A major storage form of iron found in the liver,
spleen, and bone marrow
fetal lung maturity The presence of a sufficient amount of
surfactant lipoproteins to maintain alveolar stability
first morning specimen The first voided urine specimen
collected immediately upon arising; recommended screening specimen
flatus Gas expelled from the anus
fluorescent microscopy Microscopic technique by which
naturally fluorescent substances or those that have been
stained by a fluorescent dye produce an image when
illuminated with a light of a specific wavelength
focal segmental glomerulosclerosis Disorder that affects
only certain areas of the glomerulus and produces heavy
proteinuria
fomite Inanimate object that can serve as a reservoir for
pathogenic organisms
free water clearance A test to determine the ability of the
kidney to respond to the state of body hydration
Froin syndrome Failure of spinal fluid in the spinal canal to
mix with the cerebrospinal fluid in the ventricles, producing xanthochromic, rapidly clotting cerebrospinal fluid
fructosuria The presence of fructose in the urine
galactosuria The presence of galactose in the urine
Gardnerella vaginalis Rod-shaped bacteria that causes
bacterial vaginitis
gastrocolic fistula Abnormal passageway between the
stomach and the colon
ghost cells Red blood cells that have lost their hemoglobin,
leaving only the cell membrane; appear in hyposthenuric
urine
glans The gland-like body at the tip of the penis
glomerular filtration barrier Structure of the walls of the
glomerular capillaries that prevents the filtration of large
molecules from the blood into the urine filtrate
glomerular filtration rate The volume of plasma that is
filtered by the glomerulus in a specified time
glomerulonephritis An inflammation of the glomerulus that
results in impaired glomerular filtration
glomerulosclerosis The destruction of glomeruli by scarring
and fibrin deposition
glomerulus Tuft of capillary blood vessels located in Bowman’s
capsule where filtration occurs
gout Disorder related to elevated serum uric acid that results
in the accumulation of uric acid crystals in a moveable
joint
glucose tolerance specimens Fractional collection specimens; urine specimens are collected at the same time
blood samples are drawn to compare the levels of glucose
in blood and urine
glycogenesis The conversion of glucose to glycogen
309
glycogenolysis The conversion of glycogen to glucose
glycosuria Glucose in the urine (glucosuria)
granuloma Modular accumulation of inflammatory cells
Guillain-Barré syndrome Autoimmune disorder that causes
destruction of the myelin sheath that surrounds the
peripheral nerves, resulting in loss of motor function
harmonic oscillation densitometry A method of measuring
specific gravity by measuring the change in the frequency
of a sound wave after it enters a solution
Hartnup disease A recessive inherited disorder marked by intestinal absorption abnormalities and renal aminoaciduria
hematoidin Yellow, crystalline substance that results from
the destruction of red blood cells
hematuria Blood in the urine
hemoglobinuria Hemoglobin in the urine
hemolytic disease of the newborn Rh incompatibility
between mother and fetus that can cause hemolysis of
the fetal red blood cells
hemoptysis Blood in the sputum
hemosiderin An insoluble form of storage iron; a product of
red blood cell hemolysis
hemothorax The accumulation of blood in the pleural cavity
homocystinuria The presence of homocystine in the urine
caused by an inherited autosomal recessive disorder
hyaluronic acid Glycosaminoglycan found in synovial fluid
that provides lubrication to the joints
hydramnios Excess amniotic fluid
hydrostatic pressure Pressure exerted by a liquid
hyperglycemia Elevated glucose levels in the blood
hypernatremia Elevated blood sodium levels
hypersthenuric Pertaining to urine specific gravity greater
than the 1.010 of the glomerular filtrate
hyponatremia Decreased blood sodium levels
hyposthenuric Pertaining to urine specific gravity lower
than the 1.010 of the glomerular filtrate
hypoxia Lack of oxygen
iatrogenic Pertaining to a condition caused by treatment,
medications, or diagnostic procedures
ideal body weight Statistical calculation of body weight
related to height
IgA nephropathy Damage to the glomerular membrane
caused the deposition of IgA immune complexes on the
membrane
immune complexes Antigen-antibody combinations
inborn error of metabolism Failure to inherit the gene to
produce a particular enzyme
indicanuria The presence of indican in the urine
infection control Procedures to control and monitor infections within an institution
infertility The inability to conceive
interference-contrast microscopy A procedure by which
three-dimensional images of a specimen are obtained
internal quality control Electronic, internal, and procedural
controls contained within the test system that ensures the
reliability of the test system
interstitial Pertaining to spaces between tissue cells
3920_Glossary_307-314 23/01/14 10:48 AM Page 310
310
Glossary
inulin A fructose-derived substance that is filtered by the
kidney and not reabsorbed or secreted and that can be
used to measure the glomerular filtration rate
in vitro fertilization Fertilization between an ovum and a
sperm performed in the laboratory
ischemia Deficiency of blood to a body area
isosthenuric Pertaining to urine specific gravity the same
as the 1.010 of the glomerular filtrate
jaundice Yellow appearance of skin, mucous membranes,
and eye sclera due to increased amounts of bilirubin in
the blood
juxtaglomerular apparatus Specialized cells located on the
afferent arteriole that regulate secretion of renin
ketonuria Ketones in the urine
Kohler illumination Adjustments made to the microscope
condenser when objectives are changed
labia The outer folds of the vagina
lactobacilli A group of gram-positive rod-shaped bacteria
lactosuria The presence of lactose in the urine
lamellar bodies Organelles produced by type II pneumonocytes in the fetal lung that contain lung surfactants
Langerhans cells Pancreatic cells
lecithin Phospholipid that forms part of the cell wall used
to determine fetal lung maturity
lecithin-sphingomyelin ratio A comparison of lung surfactants that is performed to determine fetal lung maturity
Lesch-Nyhan disease An inherited sex-linked recessive
purine metabolism disorder marked by excess uric acid
crystals in the urine
leukocyturia Leukocytes (white blood cells) in the urine
lipophages Macrophages that have ingested fat globules seen
in peritoneal fluid
liquefaction The conversion of solid or coagulated material
to a liquid form
lithiasis The formation of renal calculi (kidney stones)
lithotripsy A procedure that uses ultrasonic waves to crush
renal calculi
loops of Henle The U-shaped part of the renal tubule that
consists of a thin descending limb and a thick ascending
limb
lysosomes Cellular organelles that contain digestive enzymes
macula densa Specialized cells located on the distal convoluted tubule that interact with the juxtaglomerular cells
malabsorption Impaired absorption of nutrients by the
intestine
maldigestion Impaired digestion of foodstuffs
maple syrup urine disease An autosomal recessive trait that
causes increased levels of the branched-chain amino acids,
leucine, isoleucine, valine, and their ketone acids in
the urine
Material Safety Data Sheet A document provided by
the vendor or manufacturer of a chemical substance that
describes the chemical’s characteristics
maximal reabsorptive capacity The maximum reabsorption
ability for a solute by renal tubules
meconium The dark-green mucus-containing stool formed
by a fetus
medullary interstitium Spaces between the cells in the
medulla of the kidney that contain highly concentrated fluid
medulloblastomas Malignant tumor of the fourth ventricle
and cerebellum
melanoma A tumor of the melanogen-producing cells,
which is frequently malignant
melanuria Increased melanin in the urine
melituria Increased urinary sugar
meninges Protective membranes around the brain and
spinal cord
meningitis Inflammation of the meninges, frequently caused
by microbial infection
mesothelial cells Cells that line the serous membranes
metabolic acidosis A decrease in the blood pH caused by a
metabolic increase in acidic elements
microalbuminuria Low levels of urine protein that are not
detected by routine reagent strips
midstream clean-catch specimen Specimen collected in a
sterile container after cleansing the glans penis or urinary
meatus; the first portion of urine is voided into the toilet,
the midportion is collected, and the remaining portion is
voided into the toilet
Mobiluncus spp. Curved gram-variable rod-shaped bacteria
mucin Glycoprotein found in mucus and in the skin, connective tissues, tendons, and cartilage
mucopolysaccharides Glycosaminoglycans that consist of
a protein core with polysaccharide branches
mucopolysaccharidoses A group of genetic disorders marked
by excess mucopolysaccharides in blood and urine
multiple myeloma Malignant disorder that results in infiltration of the bone marrow by plasma cells
myoglobin Iron-containing protein found in muscle tissue
myoglobinuria Myoglobin in the urine
necrosis Death of cells
nephron A functional unit of the kidney that forms urine
nephropathy Disease of the kidneys
nephrotic syndrome A renal disorder marked by massive
proteinuria, lipiduria, and edema caused by disruption of
the glomerular membrane
neutrophages Vacuolated macrophages containing phagocytized neutrophils; formerly called Reiter cells
nocturia Excessive urination during the night
occult blood Blood that is not visible to the naked eye
Occupational Safety and Health Administration The
government agency created to protect employees from
potential health hazards in the workplace through the
development and monitoring of regulations
oligoclonal bands Electrophoretic bands migrating in the
gamma region that are present in cerebrospinal fluid and
serum
oligohydramnios Decreased amniotic fluid
oliguria A marked decrease in urine flow
oncotic pressure The osmotic pressure of a substance in
solution caused by the presence of colloids
organic acidemias The accumulation of organic acids in the
blood, mainly isovaleric, propionic, and methylmalonic
acids
3920_Glossary_307-314 23/01/14 10:48 AM Page 311
Glossary
orthostatic proteinuria Increased protein in urine only
when an individual is in an upright position
osmolar clearance The amount of plasma filtered each minute
to produce a urine with the same osmolarity as plasma
osmolality The osmotic pressure of a solution expressed in
milliosmoles per liter; it is only affected by the number of
particles present
osmolarity The osmotic pressure of a solution expressed
in milliosmoles per kilogram; it is affected only by the
number of particles present
osmotic diarrhea An increased retention of water and
solutes in the large intestine associated with malabsorption
and maldigestion
osmotic gradient The difference in the concentration of substances on either side of a membrane
outcomes Results of the process to improve customer
satisfaction
pancreatic insufficiency The decreased ability of the pancreas to secrete digestive enzymes
parabasal cell Cells located in the luminal squamous epithelium of the vaginal mucosa
paracentesis Surgical puncture into the abdominal cavity to
obtain peritoneal fluid
parietal membrane Serous membrane that lines the walls
of the pleural, pericardial, and peritoneal cavities
passive transport Movement of molecules across a membrane by diffusion because of a physical gradient
pentosuria The presence of pentose sugars in the urine
pericardiocentesis Surgical puncture into the pericardial
cavity to obtain pericardial fluid
pericarditis An inflammation of the membranes enclosing
the heart
peritoneal lavage Introduction and subsequent removal of
fluid into the peritoneal cavity to
Descargar