PERRY JOHNSON LABORATORY
ACCREDITATION, INC.
Certificate of Accreditation
Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
(Hereinafter called the Organization) and hereby declares that Organization is accredited
in accordance with the recognized International Standard:
ISO/IEC 17025:2017
This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system
(as outlined by the joint ISO-ILAC-IAF Communiqué dated April 2017):
Mechanical, Electrical, Dimensional, Time and Frequency, Mass, Force and
Weighing Devices, Thermodynamic and Chemical Calibration
(As detailed in the supplement)
Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this
certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the
Organization hereby covenants with the Accreditation body’s duty to observe and comply with the said rules.
For PJLA:
Initial Accreditation Date:
May 13, 2010
Issue Date:
Expiration Date:
May 04, 2021
Accreditation No.:
50911
May 04, 2023
Certificate No.:
L21-283
Tracy Szerszen
President
Perry Johnson Laboratory
Accreditation, Inc. (PJLA)
755 W. Big Beaver, Suite 1325
Troy, Michigan 48084
The validity of this certificate is maintained through ongoing assessments based
on a continuous accreditation cycle. The validity of this certificate should be
confirmed through the PJLA website: www.pjlabs.com
Page 1 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Mechanical
MEASURED
INSTRUMENT, QUANTITY
OR GAUGE
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE
Preassure GaugesFO
50 psi to 500 psi
0.89 psi
Vacuum GaugesFO
-25 inHg to -3 inHg
1.1 inHg
Force GageFO
5 kN to 45 kN
1 % of reading
Torque GageFO
5.6 N∙m to 56 N∙m
1 % of reading
Load Cell
CompressionFO
100 lb to 10 000 lb
(3.06 + 7.8 x 10-4Wt) lb
Torque AnalyzerF
10 N to 100 N
0.5 % of reading
Indirect Verification of
Rockwell Hardness
Machines HRCO
20 HRC to 39 HRC
40 HRC to 59 HRC
60 HRC to 70 HRC
0.5 L/min to 40 L/min
0.37 HRC
0.35 HRC
0.32 HRC
1.8 % of reading
Flow Meters
RotametersF
0.1 L/min to 40 L/min
4.6 % of reading
Dry Gas MetersF
(Calibration Factor)
ConsolesF (γ, ∆Ha)
(Isometric Factor)
(Calibration Factor)
High VolumenF
1 L/min to 40 L/min
4.8 % of reading
1 L/min to 40 L/min
4.4 % of reading
100 L/min to 2 600 L/min
0.55 % of reading
Piston PipettesF
10 µL to 500 µL
1 mL to 10 mL
0.62 % of reading
0.45 % of reading
Humidity GasometerFO
Issue 05/2021
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Digital Pressure Gage
BETA Gauge P.I. Pro
Ametek T-975
CENAM Technical Guide
Vacuum Gage USG
0 inHg to 30 inHg
Ametek T-750
CEM- Procedure ME-001
Transducer
Techniques, LBC-10 K
CENAM Technical Guide
Transducer Techniques
TRT-500
CENAM Technical Guide
Transducer Techniques
LWO-20
CENAM Technical Guide
Weight Class 4
Wheel of 4 in Diameter
CENAM Technical Guide
Rockwell Test Block
CENAM Technical Guide
ASTM-E18
Analytic Balance
0 gr to 12 000 gr
Gravimetric Method
NMX-AA-088
Dry Test Meter
DTM-200A
NMX-AA-088
Humid Gasometer Elster,
AL-19-3 NMX-AA-088
Humid Gasometer Elster
AL-19-3
Rotary Meter Elster, G100
NOM-035-SEMARNAT
Analytic Balance OHAUS,
DV215CD / 0 gr to 81 gr
NBX-BB-086
This supplement is in conjunction with certificate # L21-283
Page 2 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Mechanical
MEASURED
INSTRUMENT, QUANTITY
OR GAUGE
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
Test TubesF
5 mL to 50 mL
100 mL to 200 mL
0.42 % of reading
0.21 % of reading
PycnometersF
10 mL to 100 mL
0.42 % of reading
BurettesF
5 mL to 50 mL
0.16 % of reading
Beakers: ContainerF
ProbesF
10 mL to 200 mL
1 mL to 100 mL
0.21 % of reading
1.2 % of reading
500 mL to 2 000 mL
0.59 % of reading
Simple Delivery Piston
DispensersF
1 mL to 200 mL
0.23 % of reading
Volumetric Measures
with Graduated NeckF
2 L to 10 L
0.12% of reading
Volumetric Measures
with Graduated Neck to
DeliverF
2 L to 10 L
0.12 % of reading
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Analytic Balance OHAUS
DV215CD
81 gr to 210 gr
NBX-BB-086
Analytic Balance OHAUS,
DV215CD
81 gr to 210 gr
NBX-BB-086
Analytic Balance OHAUS,
DV215CD
0 gr to 81 gr
NBX-BB-086
Analytic Balance
OHAUS DV215CD
0 gr to 81 gr
NBX-BB-086
Analytic Balance
0 gr to 12 000 gr
NBX-BB-086
Analytic Balance OHAUS,
DV215CD
0 gr to 81 gr
NBX-BB-086
Analytic Balance
0 gr to 12 000 gr
NBX-BB-086
Analytic Balance
0 gr to 12 000 gr
NBX-BB-086
Chemical
MEASURED
INSTRUMENT, QUANTITY
OR GAUGE
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE
pH MetersFO
4 pH to 10 pH
0.11 pH
Conductivity MetersFO
1 413 µS/cm
5.6 µS/cm
Issue 05/2021
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
pH Buffer Solution
(4, 7, 10 pH Units)
NMX-AA-008-SCFI
Hanna Instrument,
Conductivity Solution
HI7031L/C
NMX-AA-093-SCFI
This supplement is in conjunction with certificate # L21-283
Page 3 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Mass, Force, and Weighing Devices
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Scales and BalancesO
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
1 g to 100 g
(2.27 x 10-2 + 2.73 x 10-4Wt) g
100 g to 500 g
500 g to 1 kg
1 kg to 5 kg
5 kg to 10 kg
10 kg to 25 kg
25 kg to 250 kg
(7.22 x 10-2 + 4.8 x 10-5Wt) g
(1.35 x 10-1 + 4 x 10-5Wt) g
(1.13 x 10-1 + 4.7 x 10-5Wt) g
(3.04 x 10-1 + 1.8 x 10-5Wt) g
(1.83 + 1.4 x 10-5Wt) g
(7.02 x 10-2 + 4.76 x 10-4Wt) kg
250 kg to 2 500 kg
(3.45 x 10-1 + 2.84 x 10-4Wt) kg
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Class 1 Weights
CENAM Technical Guide
Class 4 Weights
CENAM Technical Guide
Handbook 44
Verification with
Class F Weights
Thermodynamic
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
Thermal ChamberO
200 ºC to 600 ºC
1.8 ºC
Thermal OvenO
-65 ºC to 1 200 ºC
1.8 ºC
Thermal ControllersFO
40 °C to 17 60 ºC
2 ºC
HygrometersFO
10 % RH to 90 % RH
3.2 % RH
Humidity ChamberO
10 % RH to 90 % RH
3.4 % RH
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Fluke 51 II
Thermocouple Type K
CENAM Technical Guide
Fluke 5500A
Thermocouple Type K
CENAM Technical Guide
Fluke 5500 A
Thermocouple Type J, K
CENAM Technical Guide
Thermo Hygrometer
DT-321S
CENAM Technical Guide
Thermo Hygrometer
DT-321S
CENAM Technical Guide
Time and Frequency
MEASURED
INSTRUMENT,
QUANTITY OR GAUGE
ChronometersFO
Issue 05/2021
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
86 400 s
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
5.4 s
This supplement is in conjunction with certificate # L21-283
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Digital Stopwatch
CENAM Technical Guide
Page 4 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Dimensional
MEASURED
INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
Vernier CalipersF
0.5 mm to 300 mm
28 µm
MicrometersFO
0.5 mm to 25 mm
7 µm
Optical Comparators
LengthO
Optical Comparators
AngularityO
Optical Comparators
SquarenessO
Optical Comparators
MagnificationO
0.5 mm to 300 mm
20 µm
0° to 90°
0.02°
110 mm x 90 mm
21 µm
10X
20X
30X
25 mm to 1 350 mm
0.17 %
0.34 %
0.51 %
(0.95 + 5 x 10-4L) µm
25 mm
(1 in)
2.4 µm
(94 µin)
0.5 mm to 300 mm
17 µm
0.05 mm to 2 mm
(15.24 + 0.01L) µm
Measuring Machine
Coordinate
CMM PerformanceO
Measuring Machine
Coordinate
RepeatabilityO
Quik Scope, Micro
ViuO
Dial Thickness GageF
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Gage Blocks
CEM-Procedure DI-008
Gage Blocks
CEM-Procedure DI-005
Glass Scale Length
JIS B 7184
Deltronic Slide Optical
JIS B 7184
Square Master
JIS B 7184
Amplification Scale
JIS B 7184
Block Gage
ASME, Master Ball Bar
B89.4.10360.2:2008
ISO 10360-2
Master Ball Bar
ASME B89.4.10360.2:2008
ISO 10360-2
Glass Scale Length
JIS B 7184
Master Gage Block
ASME B89.1.10M
Dimensional
MEASURED
INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
Gage BlocksF
0.5 mm to 100 mm
3.3 µm
Height GageF
45.75 µm to 600 mm
(15.24 + 0.01L) µm
Pin GagesF
0.5 mm to 50 mm
2.2 µm
Issue 05/2021
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Blanchet comparator with
Master Gage Block, Mitutoyo,
Grade 1
CEM- DI-014
Thickness Gage
Master Gage Blocks
ASME B89.1.10M
Micrometer APB 3D
ASME B89.1.5
This supplement is in conjunction with certificate # L21-283
Page 5 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Dimensional
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Surface PlateO
Repeat Measurement
(over 18 in of Diagonal)
Thickness Sensor
(Electronic, Ultrasonic)FO
Plain Plug GageF
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
0.002 in
80 µin
21 µm to 150 mm
7 µm
0.25 mm to 25 mm
7 µm
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
JIS B 7513 Repeat-o-Meter
CEM - DI-015
Master Gage Block
SE-797
Micrometer
PDT-208: Internal Procedure
Electrical
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Temperature Calibration
Indication, and Control
Equipment used With
Thermocouples Type JFO
Temperature Calibration
Indication, and Control
Equipment used With
Thermocouples Type KFO
Equipment to Output
DC CurrentFO
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
-210 °C to -100 °C
0.27 °C
-99 °C to -30 °C
-29 °C to 150 °C
151 °C to 760 °C
761 °C to 1 200 °C
-200 °C to -100 C
-99 °C to -25 °C
0.17 °C
0.15 °C
0.19 °C
0.23 °C
0.35 °C
0.21 °C
-24 °C to 120 °C
121 °C to 1 000 °C
1 001 °C to 1 372 °C
0.18 µA to 999 µA
1 mA to 999 mA
1 A to 15 A
0.19 °C
0.28 °C
0.32 °C
0.004 1 % of reading
0.027 % of reading
0.25 % of reading + 0.002 A
15 A to 150 A
150 A to 550 A
0.25 % of reading + 0.015 A
0.25 % of reading + 0.05 A
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz
0.18 µA to 100 μA
4 nA/µA + 30 nA
20 Hz to 45 Hz
45 Hz to 100 Hz
100 Hz to 1 kHz
0.18 µA to 100 μA
0.18 µA to 100 μA
0.18 µA to 100 μA
1.5 nA/µA + 30 nA
0.6 nA/µA + 30 nA
0.6 nA/µA + 30 nA
Issue 05/2021
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Electrical Simulation of
Thermocouple Output
Fluke 5500A
CENAM Technical Guide
Fluke 5500A
CENAM Technical Guide
Fluke 5500A with
5500A/COIL
CENAM Technical Guide
Fluke 5500A
CENAM Technical Guide
This supplement is in conjunction with certificate # L21-283
Page 6 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Electrical
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 100 Hz
100 Hz to 5 kHz
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
Fluke 5500A
CENAM Technical Guide
0.18 mA to 1 mA
0.18 mA to 1 mA
0.18 mA to 1 mA
0.18 mA to 1 mA
4 µA/mA + 200 nA
1.5 µA/mA + 200 nA
0.6 µA/mA + 200 nA
0.3 µA/mA + 200 nA
5 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 100 Hz
100 Hz to 5 kHz
5 kHz to 20 kHz
0.18 mA to 1 mA
0.18 mA to 1 mA
0.18 mA to 1 mA
0.6 µA/mA + 200 nA
4 µA/mA + 400 nA
5.5 µA/mA + 1 500 nA
0.18 mA to 10 mA
0.18 mA to 10 mA
0.18 mA to 10 mA
0.18 mA to 10 mA
0.18 mA to 10 mA
4 µA/mA + 2 µA
1.5 µA/mA + 2 µA
0.6 µA/mA + 2 µA
0.3 µA/mA + 2 µA
0.6 µA/mA + 2 µA
20 kHz to 50 kHz
50 kHz to 100 kHz
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz
20 Hz to 45 Hz
45 Hz to 100 Hz
100 Hz to 5 kHz
5 kHz to 20 kHz
20 kHz to 50 kHz
0.18 mA to 10 mA
0.18 mA to 10 mA
4 µA/mA + 4 µA
5.5 µA/mA + 15 µA
0.18 mA to 100 mA
0.18 mA to 100 mA
0.18 mA to 100 mA
0.18 mA to 100 mA
0.18 mA to 100 mA
0.18 mA to 100 mA
4 µA/mA + 20 µA
1.5 µA/mA + 20 µA
0.6 µA/mA + 20 µA
0.3 µA/mA + 20 µA
0.6 µA/mA + 20 µA
4 µA/mA + 40 µA
Fluke 5500A
CENAM Technical Guide
50 kHz to 100 kHz
0.18 mA to 100 mA
Equipment to Measure
AC Current
At the listed frequenciesFO
10 Hz to 20 Hz
0.18 A to 1 A
4 mA/A + 0.2 mA
20 Hz to 45 Hz
1.6 mA/A + 0.2 mA
Issue 05/2021
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
0.18 A to 1 A
5.5 µA/mA + 150 µA
This supplement is in conjunction with certificate # L21-283
Page 7 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Electrical
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Equipment to Measure
AC Current
At the listed frequenciesFO
45 Hz to 100 Hz
100 Hz to 5 kHz
5 kHz to 20 kHz
20 kHz to 50 kHz
Equipment to Measure
AC Current
45 Hz to 65 Hz
Equipment to Measure
AC Current
65 Hz to 440 Hz
Equipment to Output
ResistanceFO
Equipment to Measure
AC Voltage
At the listed frequenciesFO
1 Hz to 50 kHz
50 kHz to 4 MHz
1 Hz to 300 kHz
1 Hz to 2 MHz
1 Hz to 50 kHz
50 kHz to 100 kHz
Equipment to Measure
DC VoltageFO
Issue 05/2021
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Fluke 5500A
CENAM Technical Guide
0.18 A to 1 A
0.18 A to 1 A
0.18 A to 1 A
0.18 A to 1 A
0.8 mA/A + 0.2 mA
1 mA/A + 0.2 mA
3 mA/A + 0.2 mA
10 mA/A + 0.4 mA
1 A to 15 A
1 A to 150 A
150 A to 550 A
2 A to 15 A
2 A to 150 A
151 A to 550 A
0.28 % of reading + 0.003 A
0.28 % of reading + 0.025 A
0.28 % of reading + 0.09 A
0.79 % of reading + 0.003 A
0.79 % of reading + 0.027 A
0.79 % of reading + 0.1 A
Fluke 5500A with
5500A/COIL
CENAM Technical Guide
0.017 Ω to 10 Ω
10 Ω to 100 Ω
100 Ω to 1 kΩ
1 kΩ to 10 kΩ
10 kΩ to 100 kΩ
15 µΩ/Ω + 50 µΩ
12 µΩ/Ω + 500 µΩ
10 µΩ/Ω + 500 µΩ
10 µΩ/Ω + 5 mΩ
10 µΩ/Ω + 50 mΩ
Fluke 5500A
CENAM Technical Guide
100 kΩ to 1 MΩ
1 MΩ to 10 MΩ
10 MΩ to 100 MΩ
100 MΩ to 1 GΩ
15 µΩ/Ω + 2 Ω
50 µΩ/Ω + 1 Ω
500 µΩ/Ω + 10 Ω
5 000 µΩ/Ω + 100 Ω
Fluke 5500A
CENAM Technical Guide
0 mV to 100 mV
10 mV to 100 mV
10 mV to 100 mV
100 mV to 10 V
100 V to 700 V
0.2 % of reading
0.2 % of reading
0.5 % of reading
0.8 % of reading
0.6 % of reading
100 v to 1 000 V
0.003 6 mV to 239.999 9 mV
0.6 % of reading
60 μV/V + 3 μV
This supplement is in conjunction with certificate # L21-283
Fluke 5500A
CENAM Technical Guide
Page 8 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Electrical
MEASURED
INSTRUMENT, QUANTITY
OR GAUGE
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
Equipment to Measure
DC VoltageFO
0.003 6 V to 3.299 999 V
0.003 6 V to 32.999 99 V
50 μV/V + 5 µV
50 μV/V + 50 μV
Equipment to Measure
DC CurrentFO
30 V to 329.999 9 V
100 V to 1 020 V
0.18 mA to 3.299 99 mA
0.18 mA to 32.99 99 mA
0.18 mA to 329.999 mA
0.18 A to 2.199 99 A
55 μV/V + 500 μV
55 μV/V + 1 500 μV
130 μA/A + 0.05 μA
100 μA/A + 0.25 μA
100 μA/A + 3.3 μA
300 μA/A + 44 μA
0.18 A to 11 A
0 Ω to 10.99 Ω
11 Ω to 32.999 Ω
33 Ω to 109.999 Ω
110 Ω to 329.99 9 Ω
330 Ω to 1.099 99 kΩ
600 μA/A + 330 µA
120 μΩ/Ω + 0.008 Ω
120 μΩ/Ω + 0.015 Ω
90 μΩ/Ω + 0.015 Ω
90 μΩ/Ω + 0.015 Ω
90 μΩ/Ω + 0.06 Ω
1.1 kΩ to 3.299 99 kΩ
3.3 kΩ to 10.999 9 kΩ
11 kΩ to 32.999 9 kΩ
33 kΩ to 109.999 kΩ
110 kΩ to 329.999 kΩ
330 kΩ to 1.099 99 MΩ
90 μΩ/Ω + 0.06 Ω
90 μΩ/Ω + 0.6 Ω
90 μΩ/Ω + 0.6 Ω
110 μΩ/Ω + 6 Ω
120 μΩ/Ω + 6 Ω
150 μΩ/Ω + 55 Ω
1.1 MΩ to 3.299 99 MΩ
3.3 MΩ to 10.999 9 MΩ
11 MΩ to 32.999 9 MΩ
33 MΩ to 109.999 MΩ
110 MΩ to 330 MΩ
150 μΩ/Ω + 55 Ω
600 μΩ/Ω + 0.55 kΩ
1 000 μΩ/Ω + 0.55 kΩ
5 000 μΩ/Ω + 5.5 kΩ
5 000 μΩ/Ω + 16.5 kΩ
Equipment to Measure
ResistanceFO
Equipment to Output
AC Voltage
At the listed FrequenciesFO
10 Hz to 45 Hz
1 mV to 32.999 mV
45 Hz to 10 kHz
1 mV to 32.999 mV
10 kHz to 20 kHz
1 mV to 32.999 mV
Issue 05/2021
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Fluke 5500A
CENAM Technical Guide
0.35 % of reading + 20 µV
0.15 % of reading + 20 µV
0.2 % of reading + 20 µV
This supplement is in conjunction with certificate # L21-283
Page 9 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Electrical
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Equipment to Output
AC Voltage
At the listed frequenciesFO
20 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 500 kHz
Equipment to Output
AC Voltage
at the listed frequenciesFO
10 Hz to 45 Hz
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
100 kHz to 500 kHz
Equipment to Output
AC Voltage
at the listed frequenciesFO
10 Hz to 45 Hz
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
Fluke 5500A
CENAM Technical Guide
1 mV to 32.999 mV
1 mV to 32.999 mV
1 mV to 32.999 mV
0.25 % of reading + 20 µV
0.35 % of reading + 33 µV
1 % of reading + 60 µV
33 mV to 329.999 mV
33 mV to 329.999 mV
33 mV to 329.999 mV
0.25 % of reading + 50 µV
0.05 % of reading + 20 µV
0.1 % of reading + 20 µV
33 mV to 329.999 mV
33 mV to 329.999 mV
33 mV to 329.999 mV
0.16 % of reading + 40 µV
0.24 % of reading + 170 µV
0.7 % of reading + 330 µV
330 mV to 3.29 V
330 mV to 3.29 V
330 mV to 3.29 V
330 mV to 3.29 V
330 mV to 3.29 V
0.2 % of reading 60 + 250 µV
0.03 % of reading + 60 µV
0.08 % of reading + 60 µV
0.14 % of reading + 300 µV
0.24 % of reading + 1 700 µV
100 kHz to 500 kHz
330 mV to 3.29 V
Equipment to Output
AC Voltage
at the listed frequenciesFO
10 Hz to 45 Hz
3.3 V to 32.99 V
0.5 % of reading + 3 300 µV
45 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
0.04 % of reading + 600 µV
0.08 % of reading + 2 600 µV
0.19 % of reading + 5 000 µV
0.24 % of reading + 17 000 µV
Issue 05/2021
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
3.3 V to 32.99 V
3.3 V to 32.99 V
3.3 V to 32.99 V
3.3 V to 32.99 V
0.15 % of reading + 2 500 µV
This supplement is in conjunction with certificate # L21-283
Page 10 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Electrical
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Equipment to Output
AC Voltage
at the listed frequenciesFO
45 Hz to 1 kHz
1 kHz to 10 kHz
10 kHz to 20 kHz
Temperature Calibration,
Indication and Control
Equipment used with
RTD Pt 350, 100 ΩFO
Temperature Calibration
Indication and Control
Equipment used with
RTD Pt 385, 200 ΩFO
Temperature Calibration,
Indication and Control
Equipment used with
RTD Pt 385, 200 ΩFO
Temperature Calibration
Indication and Control
Equipment used with
RTD Pt 385, 500 ΩFO
Temperature Calibration
Indication and Control
Equipment used with
RTD Pt 385, 1 000 ΩFO
Issue 05/2021
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE)
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Fluke 5500A
CENAM Technical Guide
33 V to 329.99 V
33 V to 329.99 V
33 V to 329.99 V
200 °C to -80 ºC
0.05 % of reading + 6.6 mV
0.08 % of reading + 15 mV
0.09 % of reading + 33 mV
0.05 ºC
0 °C to 100 ºC
100 °C to 300 ºC
300 °C to 400 ºC
400 °C to 630 ºC
630 °C to 800 ºC
-200 °C to -80 ºC
0.07 ºC
0.09 ºC
0.10 ºC
0.12 ºC
0.23 ºC
0.04 ºC
100 °C to 260 ºC
260 °C to 300 ºC
0.05 ºC
0.12 ºC
300 °C to 400 ºC
400 °C to 600 ºC
600 °C to 630 ºC
0.13 ºC
0.14 ºC
0.16 ºC
-200 °C to -80 ºC
0.04 ºC
-80 °C to 0ºC
100 °C to 260 ºC
260 °C to 300 ºC
300 °C to 400 ºC
400 °C to 600 ºC
600 °C to 630 ºC
0.05 ºC
0.06 ºC
0.08 ºC
0.08 ºC
0.09 ºC
0.11 ºC
-200 °C to -80 ºC
0 °C to 100 ºC
100 °C to 260 ºC
260 °C to 300 ºC
300 °C to 400 ºC
400 °C to 630 ºC
0.03 ºC
0.04 ºC
0.05 ºC
0.06 ºC
0.07 ºC
0.23 ºC
This supplement is in conjunction with certificate # L21-283
Fluke 5500A
Electrical Simulation of
RTD Output
CENAM Technical Guide
Page 11 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
Electrical
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
Temperature Calibration,
Indication and Control
Equipment used with
RTD Pt 3929, 100 ΩFO
Temperature Calibration,
Indication and Control
Equipment used with
RTD Pt 3916, 100 ΩFO
RANGE OR NOMINAL DEVICE
SIZE AS APPROPRIATE
CALIBRATION AND
MEASUREMENT
CAPABILITY EXPRESSED
AS AN UNCERTAINTY (±)
-200 °C to 0 ºC
0 °C to 100 ºC
0.05 ºC
0.07 ºC
100 °C to 260 ºC
260 °C to 300 ºC
400 °C to 630 ºC
-200 °C to -190 ºC
-190 °C to -80 ºC
-80 °C to 0 ºC
0.09 ºC
0.1 ºC
0.12 ºC
0.25 ºC
0.04 ºC
0.05 ºC
0 °C to 100 ºC
100 °C to 260 ºC
260 °C to 300 ºC
300 °C to 400 ºC
400 °C to 600 ºC
-80 °C to 100 °C
0.06 ºC
0.07 ºC
0.08 ºC
0.09 ºC
0.1 ºC
0.08 °C
Temperature Calibration,
Indication and Control
-100 °C to 260 °C
Equipment used with
RTD Pt Ni l 385, 120 ΩFO
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Fluke 5500A
Electrical Simulation of
RTD Output
CENAM Technical Guide
0.3 °C
1.
The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of
accreditation represents the smallest measurement uncertainty attainable by the laboratory when performing a
more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is typically expressed
at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual measurement
uncertainty associated with a specific calibration performed by the laboratory will typically be larger than the
CMC for the same calibration since capability and performance of the device being calibrated and the
conditions related to the calibration may reasonably be expected to deviate from ideal to some degree.
2.
The laboratories range of calibration capability for all disciplines for which they are accredited is t he interval
from the smallest calibrated standard to the largest calibrated standard used in performing the calibration. The
low end of this range must be an attainable value for which the laboratory has or has access to the standard
referenced. Verification of an indicated value of zero in the absence of a standard is common practice in the
procedure for many calibrations but by its definition it does not constitute calibration of zero capacity.
3.
The presence of a superscript F means that the laboratory performs calibration of the indicated parameter at
its fixed location. Example: Outside MicrometerF would mean that the laboratory performs this calibration at
its fixed location.
4.
The presence of a superscript O means that the laboratory performs calibration of the indicated parameter
onsite at customer locations. Example: Outside MicrometerO would mean that the laboratory performs this
calibration onsite at the customer’s location.
Issue 05/2021
This supplement is in conjunction with certificate # L21-283
Page 12 of 13
Certificate of Accreditation: Supplement
Hardt Calibration Laboratory S. de R.L. de C.V.
Florentino Izaguirre No 17, Col. Ejido lucio Blanco
Matamoros, Tamaulipas, México. C.P. 87444
Contact Name: Eliezer Reinhardt Phone: (52) 868-127-1861
Accreditation is granted to the facility to perform the following calibrations:
5.
The presence of a superscript FO means that the laboratory performs calibration of the indicated parameter
both at its fixed location and onsite at customer locations. Example: Outside MicrometerFO would mean that
the laboratory performs this calibration at its fixed location and onsite at customer locations.
6.
Measurement uncertainties obtained for calibrations performed at customer sites can be expected to be larger
than the measurement uncertainties obtained at the laboratories fixed location for similar calibrations. This is
due to the effects of transportation of the standards and equipment and upon environmental conditions at the
customer site which are typically not controlled as closely as at the laboratories fixed location.
7.
The term L represents length in inches or millimeters as appropriate to the uncertainty statement.
8.
The term Wt represents weight in pounds or grams (including SI multiple and submultiple units) appropriate
to the uncertainty statement.
Issue 05/2021
This supplement is in conjunction with certificate # L21-283
Page 13 of 13